Specifications 015105 'w P ( r P52009 - 0009 7 R&EVED co Fire & Building . Products , ,,,,-- tia <; -_... 0 OF TGAR Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Fv7ax2 DIvIsco Series TY -B — 2.8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage cable approval agencies, the testing is G eneral not representative of all possible cor- ,� y , _ 4= rosive atmospheres. Consequently, it ' Description is recommended that the end user be , r— _ ' consulted with respect to the suitability The Series TY -B, 2.8, 5.6, and 8.0 of these coatings for any given corro- K- factor, Upright and Pendent Sprin- sive environment. The effects of ambi- I ort ) klers described in this data sheet are ent temperature, concentration of ". r at 1 standard response - standard cover- chemicals, and gas /chemical velocity, age, decorative 5 mm glass bulb type should be considered, as a minimum, spray sprinklers designed for use in along with the corrosive nature of the .-, light, ordinary, or extra hazard, corn- chemical to which the sprinklers will be — �� mercial occupancies such as banks, exposed. — "=— hotels, shopping malls, factories, refin- eries, chemical plants, etc. An intermediate level version of the Series TY -B Pendent Sprinkler can be The recessed version of the Series obtained by utilizing the Series TY -B _/omulsoft,,,.. TY -B Pendent Sprinkler, where appli- Pendent Sprinkler in combination with cable, is intended for use in areas with the Model S2 Shield. . a finished ceiling. It uses a two -piece Style 10 (1/2 inch NPT) or Style 40 (3/4 WARNINGS /- // inch NPT) Recessed Escutcheon. The The Series TY -B Sprinklers described Recessed Escutcheon provides 1/2 herein must be installed and main- x inch (12,7 mm) of recessed adjust- tained in compliance with this docu- ment or up to 3/4 inch (19,1 mm) of ment, as well as with the applicable . total adjustment from the flush pen- standards of the National Fire Protec- .k ' dent position. The adjustment pro- tion Association, in addition to the « , vided by the Recessed Escutcheon re- standards of any other authorities hay - duces the accuracy to which the fixed ing jurisdiction. Failure to do so may — pipe drops to the sprinklers must be impair the performance of these de- cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain - applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- Model/Sprinkler IMPORTANT Identification Always refer to Technical Data Sheet TFP700 for the "INSTALLER Numbers WARNING" that provides cautions with respect to handling and instal- TY1151 - Upright 2.8K, 1/2"NPT • lation of sprinkler systems and corn- TY1251 - Pendent 2.8K, 112 "NPT ponents. Improper handling and in- TY3151 - Upright 5.6K, 112 "NPT stallation can permanently damage TY3251 - Pendent 5.6K, 1/2"NPT a sprinkler system or its compo- TY4151 - Upright 8.0K, 314 "NPT nests and cause the sprinkler to fail TY4251 - Pendent 8.0K, 314 "NPT to operate in a fire situation or cause TY4851 - Upright 8.0K, 1/2"NPT it to operate prematurely. TY4951 - Pendent 8.0K, 112 "NPT Page 1 of 8 DECEMBER, 2007 TFP151 Page 2 of 8 TFP151 • ESCUTCHEON • 7/16" (11,1 mm) • PLATE SEATING „ * *. NOMINAL SSU . ■ • SURFACE NPT MAKE -IN DEFLECTOR 1 6 5 2 -1/4" 2-3/1 6" ' (57,2 mm) I I ' (55,6 mm) 4 , 1 -9/16 WRENCH I 6 ' A � (39,7 mm) FLATS �� \ 7j, . ;7777 1 SSP 7 DEFLECTOR CROSS PENDENT UPRIGHT SECTION • . 1 3 - Sealing 4 - Bulb . 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. • Screw * *Pipe thread connections per ISO 7/1 can be provided on - special request. , FIGURE 1 - - • STANDARD RESPONSE SERIES TY -B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS . . 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 • • PLATE SEATING „ ** NOMINAL RECESSED * SURFACE 1/2 MAKE -IN ESCUTCHEON SSU • NPT DEFLECTOR It '. aFiiiiiiarofiii6■1■N rr 7/16” �' 5 2 -3/16" i•r (111 mm) i . (55,6 mm) A i jT ' NOMINAL I 4 • i _ 1 Jr 1,1/2" ' I ds_r 1 ( 556 / mm) * V $ H — . WRENCH 3 - �a ��rs -. FLATS 1 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. —* 1/2" NPT ** f. PENDENT RECESSED PENDENT UPRIGHT ' CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or to 2 - Button Assembly 5 - Compression orifice seat on frame. . Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT • • • TFP151 Page 3 of 8 • . ESCUTCHEON • 1/T (12,7 mm) • STYLE 40 PLATE SEATING ' , ** NOMINAL RECESSED ' SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR • m'l t t r�'TTIMI T'� 6* • I 1 /2" 5 2- 5/16" re ( mm) (58,7 mm) �=1 NOMINAL 4 MAKE -IN 1 9/16" � __ 21/4" Y ' � 2 . (39,7 mm) ' I � (57,2 mm) � 3 i II ■ WRENCH l li P FLATS 1 fffm 1 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. — " - 1 3/4" NPT ** f - PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is_ indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per.ISO 7/1 can be provided on special request. - . • . • FIGURE 3 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT , ESCUTCHEON 7/16".(11,1 mm) • PLATE SEATING 1/2" ** NOMINAL SSU • SURFACE NPT MAKE -IN DEFLECTOR F— ________...—. e __ r .......,, * 6 • '_` 5 2 -1/4" " 7 (57,2 mm) II �I oil 5,6 2- 316 m 4 1- 9/16" 4i0 WRENCH � r ?v .„______ _.___ ___ _.____ .,__ ___ ____ ' ; (39,7 mm) F LATS P , 3 SSP DEFLECTOR. CROSS PENDENT UPRIGHT ' SECTION . 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating.is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT • Page 4 of 8 TFP151 • SPRINKLER FINISH (See Note 8) • - K TYPE TEMP. BULB NATURAL CHROME WHITE*" LEAD - WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red • 2.8 (TY1251) 1, 2, 3 N/A 1/2" and 175 °F /79 °C Yellow NPT UPRIGHT 200 °F /93 °C Green (TY1151) 286°F/141°C Blue 360 °F /182 °C Mauve 1, 2 135 °F /57 °C Orange PENDENT 155"F168°C Red 3 1, 2, 3, 4, 5, 6, 7 1,2,3,5 1,2,3,5 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200"F/93°C Green 5.6 (TY3151) 286°F/141°C Blue 1",2", 3" 5 ** FT- 2 *' 3 ** 5** 1/2" NPT 360 °F /182 °C Mauve N/A • 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red • PENDENT 1, 2, 3, 4, 5 N/A (TY3251)* 175F/79°C Yellow Figure 4 200 °F /93 °C Green • 286 °F /141 °C Blue 1, 2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red ( ) 1,2,5 1,2,3,5 1,2,5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 200 °F /93 °C Green 3/4" 286°F/141°C Blue 1",2", 3 ** 5" 1" 2", 5 ** NPT .. 360"F/182°C Mauve I N/A : 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red • PENDENT 1, 2, 3, 4, 5 N/A (TY4251)* 175 °F /79 °C Yellow • Figure 5 200 °F /93 °C Green 286 °F /141 °C Blue 1, 2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4951) 1/2" and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6 N/A NPT UPRIGHT 200 °F /93 °C Green • (TY4851) • 286 °F /141 °C Blue • 360 °F /182 °C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss` Prevention Certification Board (LPCB Ref. No. 007k/03). ' 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax. over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150 °F /66 °C Maximum Ceiling Temperature. "* Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER . BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 PENDENT (TY1251) 1/2" and 175 PSI (12,1 BAR) N/A . NPT UPRIGHT (TY1151) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2" UPRIGHT (TY3151) OR NPT RECESSED PENDENT 175 PSI (12,1 BAR) (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) . 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A • 8.0 PENDENT (TY4951) . • - - 1/2" and - 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Operation Data The glass Bulb contains a fluid which • expands when exposed to heat. When Approvals • the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the . FM, LPCB, VdS, and NYC Approved. glass ,Bulb, allowing the sprinkler to (Refer to Table A for complete ap- . activate and water to flow. . proval information including corrosion . - resistant status.) Design Maximum Working Pressure , Refer to Table B. Criteria Discharge Coefficient K = 2.8 GPM /psi / (40,3 LPM /barl/2) The Series TY -B Pendent and Upright K = 5.6 GPM /psi / (80,6 LPM /bar1 /2 Sprinklers are intended for fire protec- K = 8.0 GPM /psi (115,2 LPM /bar1 /2) tion systems designed in accordance . with the standard installation rules rec- Temperature Ratings ognized by the applicable Listing or • Refer to Table A. Approval agency (e.g., UL Listing is . Finishes based on the requirements of NFPA Sprinkler: Refer to Table A. 13, and FM Approval is based on the Recessed Escutcheon: White Coated, requirements of FM's Loss Prevention , , Chrome Plated, or Brass Plated. Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, 1 Physical Characteristics is to be used for recessed pendent Frame Bronze installations. F- . Button Brass /Copper 0 Sealing Assembly .`? Beryllium Nickel w /Teflont Bulb Glass w t. Compression Screw Bronze o Deflector Copper a Bushing (K =2.8) Bronze o i- Page 6 of 8 TFP151 ' 2 -7/8" DIA. _ Lv 5/8 ±1/4" (73,0 mm) ' 3/4" (19,1 mm) . - (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) WRENCH RECESS 57,2 mm (END "A" USED FOR FACE OF ( ) MOUNTING .... 1/2" NPT MODELS) SPRINKLER PLATE "' FITTING 1/8" WRENCH RECESS z�' (3,2 mm) (END "B" USED FOR 1 1 •1I - 3/4" -NPT MODELS) i i i , F IGURE 7 v � �� , l W -TYPE 6 SPRINKLER 4 WRENCH t MOUNTING SURFACE ' WRENCH CLOSURE SERIES 1 -1/4" (31,8 mm) RECESS TY B 3/4" (19,1 mm) FIGURE 5 ' SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY . WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT %I`a' PUSH 'WRENCH IN TO ENSURE • 2 - 7/8" DIA. ENGAGEMENT (73, . . WITH SPRINKLER 5/8±1 /4" 0 mm) 3/4" (19,1 mm) . WRENCHING AREA (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FIGURE (57,2 mm) FACE OF MOUNTING W 7- RECESSED SPRINKLER PLATE SPRINKLER WRENCH FITTING • � . - 1/8" . „rll (3,2 mm) Installation A l MI = e r , The Series TY -B Sprinklers must be I 6 - - installed in accordance with the follow - ing instructions: MOUNTING NOTES D SURFACE o not install an 111, • type sprinkler if any bulb yp p the bulb is cracked or there is a loss of CLOSURE SERIES 1- 5/16" (33,3 mm) liquid from the bulb. With the sprinkler TY-B 13/16" 20,6 mm) held horizontally, a small air bubble ( ) should be present. The diameter of the air bubble is approximately 1/16 inch FIGURE 6 (1,6 mm) for the 135 °F /57 °C to 3/32 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY tech mm) for the 360 °F /182 °C WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT temperratat ure ratings. STYLE 40 RECESSED ESCUTCHEON A 1/2 inch NPT sprinkler joint should 8.0 K- FACTOR, 3/4 INCH NPT be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of 1, the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon plate by under- or over - tightening the • TFP151 Page 7 of 8 • sprinkler. Readjust the position of the The Series TY -B Recessed Pendent and after installation. Sprinklers dam - sprinkler fitting to suit. Sprinklers must be installed in ac- aged by dropping, striking, wrench The Series TY -B Pendent and Up- cordance with the following instruc- twist/slippage, or the like, must be re- right Sprinklers must be installed in tions. placed. Also, replace any sprinkler • accordance with the following instruc- Step A. After installing the Style 10 or that has a cracked bulb or that has lost tions. 40 Mounting Plate, as applicable, over liquid from its bulb. (Ref. Installation Section). the sprinkler threads and with pipe Step 1. Pendent sprinklers are to be thread sealant applied to the • installed in the pendent position, and pp pipe Frequent visual inspections are rec- upright sprinklers are to be installed in threads, hand tighten the sprinkler into ommended to be initially performed for the upright position. the sprinkler fitting. corrosion resistant coated sprinklers, Step B. Tighten the sprinkler into the after, the installation has been com- Step 2. With pipe thread sealant ap- sprinkler fitting using only the W -Type pleted, to verify the integrity of the cor- plied to the pipe threads, hand tighten 7 Recessed Sprinkler Wrench (Ref. rosion resistant coating. Thereafter, the sprinkler into the sprinkler fitting. annual inspections per NFPA 25 Figure 8). With reference to Figure 3 Step 3. Tighten the sprinkler into the or 4, the W -Type 7 Recessed Sprinkler should suffice; however, instead of in- sprinkler fitting using only the W -Type Wrench is to be applied to the sprinkler specting from the floor level, a random 6 Sprinkler Wrench (Ref. Figure 7), wrench flats. sampling of close -up visual b- except that an 8 or 10 inch adjustable tions should be made, so as to better • Crescent wrench is to be used for wax Step C. After the ceiling has been in- determine the exact sprinkler condi- coated sprinklers. With reference to stalled or the finish coat has been ap- tion and the long term integrity of the plied, slide on the Style 10 or 40 Clo- corrosion resistant coating, as it may Figures 1, 2, 3, and 4 the W -Type 7 Sprinkler Wrench or the adjustable sure over the Series TY -B Sprinkler be affected by the corrosive conditions Crescent wrench, as applicable is to and push the Closure over the Mount- present. ' be applied to the wrench flats. ing Plate until its flange comes in con- tact with the ceiling. The owner is responsible for the in- When installing wax coated sprinklers spection, testing, and maintenance of with the adjustable Crescent wrench, their fire protection system and de- additional care needs to be exercised Care and vices in compliance with this docu- to prevent damage to the wax coating ment, as well as with the applicable on the sprinkler wrench flats or frame Ma standards. of the National Fire Protec- arms and, consequently, exposure of tion Association (e.g., NFPA 25), in bare metal to the corrosive environ- The Series TY -B Sprinklers must be • addition to the standards of any other ment. The jaws of the wrench should maintained and serviced in accord- authorities having jurisdiction. The in- be opened sufficiently wide to pass ance with the following instructions: stalling contractor or sprinkler menu- over the wrench flats without damag- N OTES facturer should be contacted relative • ing the wax coating. Before wrench to any questions. • tightening the sprinkler, the jaws of the Before closing a fire protection system wrench are to be adjusted to just con- main control valve for maintenance Automatic sprinkler systems should be tact the sprinkler wrench flats. After work on the fire protection system that inspected, tested, and maintained by • wrench tightening the sprinkler, loosen it controls, permission to shut down the a qualified Inspection Service in ac- the wrench jaws before removing the affected fire protection system must be cordance with local requirements wrench. obtained from the proper authorities and /or national codes. and all personnel who maybe affected • After installation, the sprinkler wrench by this action must be notified. flats and frame arms must be in- spected and the wax coating re- The owner must assure that the sprin- touched (repaired) whenever the coat- klers are not used for hanging of any ing has been damaged and bare metal objects; otherwise, non- operation in • is exposed. The wax coating on the the event of a fire or inadvertent opera- wrench flats can be retouched by gen- tion may result. tly applying a heated 1/8 inch diameter Absence of an escutcheon, which is • steel rod to the areas of wax that have used to cover a clearance hole, may been damaged, to smooth it back over delay the time to sprinkler operation in • areas where bare metal is exposed. a fire situation. NOTES Sprinklers that are found to be leaking Only retouching of the wax coating ap- or exhibiting visible signs of corrosion plied to the wrench flats and frame must be replaced. arms is permitted, and the retouching Automatic sprinklers must never be is to be performed only at the time of painted, plated, coated or otherwise • the initial sprinkler installation. altered after leaving the factory. Modi- • The steel rod should be heated only to fied sprinklers must be replaced. . • the point at which it can begin to melt Sprinklers that have been exposed to the wax, and appropriate precautions corrosive products of combustion, but need to be taken, when handling the have not operated, should be replaced heated rod, in order to prevent the if they cannot be completely cleaned • installer from being burned. by wiping .the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, Page 8 of 8 TFP751 P/N 57 -XXX -X- XXX SPRINKLER TEMPERATURE MODEUSIN ' RATING . 530 2.8K UPRIGHT (1/2 "NPT) TY1151 1 NATURAL BRASS 135 135 °F /57 °C 531 2.8K PENDENT (1/2 "NPT) TY1251 4 WHITE POLYESTER 155 155 °F /68 °C 570 5.6K UPRIGHT (1/2 "NPT) TY3151 3 WHITE (RAL9010) * 175 175F/79°C 571 5.6K PENDENT (1/2 "NPT) TY3251 9 CHROME PLATED 200 200 °F /93 °C 590 8.0K UPRIGHT (3/4 "NPT) TY4151 7 LEAD COATED 286 286F/141°C 591 8.0K PENDENT (3/4 "NPT) TY4251 6 WAX COATED 360 360 °F /182 °C 286F/141°C MAX. , 560 8.0K UPRIGHT (1/2 "NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT (1/2 "NPT) TY4951 286 °F /141 °C MAX. • ' Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY -B PENDENT AND UPRIGHT SPRINKLERS any other legal theory, for incidental, Limited indirect, special or consequential dam- Ordering ages, including but not limited to labor Warranty charges, regardless of whether TFBP Procedure , was informed about the possibility of Products manufactured by Tyco Fire & such damages, and in no event shall When placing an order, indicate the Building Products (TFBP) are war TFBP's liability exceed an amount full product name. Refer to the Price ranted solely to the original Buyer for equal to the sales price. List for complete listing of Part Num- - • ten (10) years against defects in mate- - . bers.. rial and workmanship when paid for The foregoing warranty is made in lieu. , _ , and properly installed and maintained of any and all other warranties. ex- ontact your local distributor for avail - under normal use and service. This press or implied: including warranties ability.. warranty will expire ten (10) years of merchantability and fitness fora par - from date of shipment by TFBP. No titular putpose, Sprinkler Assemblies with NPT Thread Connections: warranty is given for products or com- This limited warranty sets forth the ex- Specify: (Specify Model /SIN), Stand - ponents manufactured by companies clusive remedy for claims based on and Response, (specify K- factor), not affiliated by ownership with TFBP failure of or defect in products, materi- (specify temperature rating), Series or for products and components which als or components, whether the claim TY -B (specify Pendent or Upright) have been subject to misuse, improper is made in contract, tort, strict liability Sprinkler with (specify type of finish or installation, corrosion, or which have or any other legal theory. coating), P/N (specify from Table C). not been installed, maintained, modi- fled or repaired in accordance with ap- This warranty will apply to the full ex- Recessed Escutcheon: plicable Standards of the National Fire tent permitted by law. The invalidity, in Protection Association, and /or the whole or part, of any portion of this S pec i fy: ,Style (specify 10 or 40 ) Re- standards of any other Authorities warranty will not affect the remainder. cessed Escutcheon with (specify*) fin - Having Jurisdiction. Materials found ish, P/N (specify). by TFBP to be defective shall be either • Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: - authorizes any person to assume for it, . Specify: W -Type 6' Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or_parts of prod- Specify: W -Type 7 Sprinkler Wrench, ucts. TFBP shall not be responsible for P/N 56- 850 -4 -001. sprinkler system design errors or inac- curate or incomplete information sup- . plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446