Loading...
Plans[Page Too Large for OCR Processing] /UI - ©o5Io, coo sw Pe-4c1-N-1 0 , TRINE' Submittal 2� • • • Prepared For: Date: November 15, 2011 ' Diane Gardner HVAC Inc. Job Name: Fanno duct heater [rev 10 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Variable Air Volume Single Duct Terminal Units . The attached information describes the equipment we propose to, furnish for this project, and is submitted for your approval. • Daniel Driver Trane Phone: (503) 620 -8031 Fax: (503) 639 -1454 NOTE: 1. VAV box is shown for informational purposes only. VAV box is existing and only duct heater is being added. • • • • • • • J :IJOBSI124148188111sub .doc • • Table Of Contents Product Summary 1 Variable Air Volume Single Duct Terminal Units (Item Al) Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 4 Unit Dimensions 5 Field Wiring 6 • • Fanno duct heater [rev 10 "] . November 15, 2011 ` Tag Data = Variable Air Volume Single Duct Terminal Units (Qty: 1) i ltem Tag(s) Qty Description Model Number Al 10" 1 Variable Air Volume Sirigle Duct Terminal VCEF10 Product Data - Variable Air Volume Single Duct Terminal Units ' • Item: Al Qty: 1 Tag(s): 10" • • Single duct with electric heat ': 10 inlet size _ Matte faced insulation - 1/2" . DDC, controls on /off electric heat control . Standard actuator Left hand 480/24 volt transformer Disconnect switch • Power Fuse 480 volt, 3 phase Electric heater kW - 6.0 • Stages - 2 - equal Magnetic contactors - 24 volt Performance Data - Variable Air Volume Single Duct Terminal Units Tags • 10" . Design cooling airflow (cfm)' 1200 - . Min cooling airflow (cfm) 360: Valve heating airflow.(cfm) 500 • C • ooling inlet diameter 10" Cooling inlet velocity (ft/min) 2200 APD @ cooling airflow (in H2O) 0:040 . - Full load amps (A) 7.22 Min circuit ampacity (A) 9.02 Max fuse size (A) 15.00 Operating weight (Ib)' 46.0 l. • Coil heating capacity (MBh) 20.49 Room heat loss (MBh) 12.35 . Room heating setpoint (F) 70.00 • Primary EDB (F) .' 55.00 . . Unit LAT.(F) . • 92.77 • ,Electric heat kW (kW) 6.00 • • • FLD,= Furnished by Trane-U.S. Inc. / Installed by Equipment Submittal • Page 3 of 7 Others • . Fenno duct heater [rev 10 "] . November 15, 2011 Mechanical Specifications - Variable Air Volume Single Duct Terminal Units , Item: Al Qty: 1 Tag(s): 10" • • Electric Heat Coil Factory provided and mounted, UL recognized, resistance open -type heater with airflow switch, a disc -type automatic . pilot duty thermal primary cutoff, and manual reset load carrying thermal secondary device. Heater element material is • nickel- chromium. The heater terminal box is provided with 7/8" knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. Heater control access is left hand. Right hand control access is optional. • Magnetic Contactor An electric, heater 24 volt contact for use with Direct Digital Control (D.D.C.) or Analog Electronic VAV Controls. Power Disconnect Switch (for VCEF) A factory provided interlocking door disconnect switch located on the electric heater control. panel. Line Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater for VCEF. For VCCF and VCWF, the fuse is installed on the primary voltage hot leg in a control box. Electric Heat Transformer A 40VA or 75VA transformer will be an integral component of the heater control panel dependent on unit load requirements to provide 24 VAC for controls. • • • • • • • FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal • Page 4 of 7 Others. • • - Fenno duct heater [rev 10 "] November 15; 2011 q, Unit Dimensions - Variable Air Volume Single Duct Terminal Units • Item: Al Qty: 1 Tag(s): 10" , • • • 2 3/4' -•:-- L — 10• a-5 1/2'-0 ELECTRIC NEATER . CONTROL BOX CONTROLS AREA a• --- 1 ' I AIR VALVE sv� I I I • ACTUATOR AIR FLOW 41 • - . \[iT . . I 0 I IP ... I N 10 I 01 - 41110! . - a3 yr • 26' • Customer Notes ' 1. Air Inlet Is centered in unit front panel. • • :i..___ 2. Slip 8 Drive discharge outlet on heater standard. 5"—C. 3 . Mow 48' of svaight duct downstream of unit before first runout 8 inside of the duct should be equal discharge size. (Ax B) TOP VIEW 15.1/2• -� SupdDRIVE _ CONNECTION 4. For electric heater access, side' . hinged door must have minimum distance , per NEC or local code. 5. Knockouts for power supply provided • • - in top 8 bottom of terminal box. • l' 20 -s 6. Coils are provided without internal insulation. If the unit is to be installed in a location 1 q• __� ' with high humidity, external insulation around the heating coil should be installed es • required. 8 1/4' [ 12' 13 1/2' . - A pp ro ximate . Dry Weight - 46.0, lb • • Weights reflected may vary: ' • BACK VIEW ±5.0 lb based upon options selected. • • .FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 5 of 7 Others - • • ei Fanno. duct heater [rev 10 1 November 15, 2011 Field Wiring - Variable Air Volume Single Duct Terminal Units Item: Al Oty: 1 Tag(s): 10" • HEA STAGE — 7 24VAC 60HZ CONTACTOR(S) NEC CLASS -2 Q I OPTIONAL I CONTROL CIRCUIT TRANSFORMER I I LOAD= 12VA r 1.13-TI 1 3 TB11 ® — — — (WITHD I TBi2 � TB25 T& � 78.3.2 j I I I I I I I I 6 b RI RI t I I II 10 7 6 3 2 I I of i - g >I di DIGITAL DISPLAY ZONE SENSOR Wl COMM. JACK REMOTE MTD. > G as cc OPTIONAL FIELD INSTALLED I I L_ DIGITAL DISPLAY ZONE SENSO J I r TB2•R TEGI 1 I 7132.5 TB3-2 I I I I I T113.3 , I I I (-- -- - J I I I I I 1 J i+0 L. I 1 ii ffff""""IIII __� 1111 2(•) 11.) J 3 2 1 LL u u W/ COMAE JACK ACT REMOTE MTD. RIP GND 24V CI C/ ADDRESS D.D.C.1U.C.M. OPTIONAL FIELD SW FTCH J7 L INSTALLED ZONE SENSOR 1 LE CONTROL BOARD e r � � FW , IBB9BB9I ;i O' 4V RBI.II 24V i ,, 4 i n i n c i� ❑ G N ,A� iLI i� h C O2 cot oIj V (TB") NCO2 pL a '�' SENSOR GND 0 "34) GND ZONE GND SET AIC'Y2 GND OPTIONAL FIELD INSTALLED L CO2 SENSOR J k j r - - - -, Z 2 O TB3 -5 1 r 103.8 I I IP SHIELDED TWISTED PAIR) COMMUNICATIONS WIRING OPTIONAL FACTORY INSTALLED WIRELESS OPTIONAL r 1 L AUKTEMPSENSOR J BL OPTIONAL FACTORY INSTALLED Y 1 r - - 1 WIRELESS I R lbn (T8I•I) 24VAC O 100MMONI - _ (TBI.I BP -- _ _ Y I I DR (NCCONTACT) - BN5jRETURNI (TBI.2)GNO j 24VAC BL (TBII GNO Y- NOT CONNECTED ~ - m UUU OPTIONAL FIELD INSTALLED L OCCUPANCY SENSOR J GND 24V / WARNING YY B° J HAZARDOUS VOLTAGEI DISCONNECT ALL ELECTRIC POWER NOTE: INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. • FAILURE TO DISCONNECT POWER I FACTORY WIRING BEFORE SERVICING CAN CAUSE - - FIELD WIRING SEVERE PERSONAL INJURY OR DEATH. - - - - OPTIONAL OR ALTERNATE WIRING 8 CAUTION USE COPPER CONDUCTORS ONLY! < 2. I ZONE SENSOR TERMINALS 1 ( -) AND 2 (0 REQUIRE SHIELDED TWISTED PAIR WIRING FOR UNIT TERMINALS ARE NOT DESIGNED COMMUNICATIONS JACK EQUIPPED ZONE SENSOR OPTION. • TO ACCEPT OTHER TYPES OF CONDUCTORS. CC] NO ADDITIONAL WIRING REQUIRED FOR NIGHT SETBACK OVERRIDE (ON/CANCEL). FAILURE TO 00 50 MAY CAUSE DAMAGE TO THE EOLAPMENT. �4 ZONE SENSOR TERMINALS 6 AND 7 REQUIRE SHIELDED TWISTED PAIR • WIRING FOR OP rIONAL USE OF COMMUNICATIONS JACK. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 017 Others • .1 • Fanno duct heater [rev 101 November 15, 2011 `1' Field Wiring - Variable Air Volume Single Duct Terminal Units •Item: Al Oty: 1 Tag(s): 10" • • • NOTE: BALANCED LINE VOLTAGE ' • REFERS TO AN EQUAL AMP LOAD ON 3 HOT WIRES L1 =L2.1.3. 480 Volt, 3 Phase - • L3 L2 LI I I I I I I�- I I I . I I I 1 I I I � • ICI Healer ' Controls • Wiring • • • • • • • • • • • FLD = Furnished•by Trane U.S. Inc. / Installed by Equipment Submittal Page 7of 7 Others , • •