Loading...
Permit A CITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2001 -00290 I n DEVELOPMENT SERVICES DA TE ISSUED: 8/15/01 `' ��I I I 13125 SW Hall Blvd.. Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 16305 SW WOODCREST AVE PARCEL: 2S1146A -10200 SUBDIVISION: COPPER CREEK STAGE 2 ZONING: R -4.5 BLOCK: LOT: 057 JURISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: NeT I FIRST: sf N: S: E: W: TYPE OF USE: SF SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: OCCUPANCY GRP: R3 TOTAL AREA: 0.00 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 10,000.00 Remarks: Deck demo and rebuild. 560 sq. ft. Owner: Contractor: SLATER, STACEY C TALLY INC. 16305 SW WOODCREST AVE PO BOX 10042 TIGARD, OR 97224 PORTLAND, OR 97296 Phone: Phone: 503 - 241 -7255 Reg #: LIC 146927 FEES REQUIRED INSPECTIONS Type By Date Amount Receipt Footing Insp PLCK CTR 8/10/01 $90.55 27200100000 Framing Insp Final Inspection PRMT CTR 8/15/01 $139.30 27200100000 5PCT CTR 8/15/01 $11.14 27200100000 Total $240.99 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a copy of these rules or direct questions to OUNC by calling (503) 246 -6699 or 1- 800 - 332 -234 S i na S / .)/ _: ignaure: X / Issued By: .4 ` /, . . \' Call 639 -4175 by 7 p.m. for an inspection the next business day 1 / l Building Permit : ; . tion � ate received. � p O 1 Permit no.: 1 —00 1 t ) ,yl City of Tigard T i J - 6 ''- Project/appl. no.: Expire date: City ojTigard Address: 13125 SW Hall BI d, Tigard, OR ` 223 Phone: (503) 639 - 4171 Date issued: By: Receipt no.: Fax: (503) 598 -1960 Case file no.: Payment type: Land use approval: 1 &2 family: Simple Complex: \ TYPE OF PERMIT ❑ 1 & 2 family dwelling or accessory ❑ Commercial /industrial ❑ Multi- family ❑ New construction 'Li Demolition ( Addition/alteration /replacement ❑ Tenant improvement ❑ Fire sprinkler /alarm ❑ Other: - . JOB SITE.INFORMATION Job address: 1/305 S "J 1/•47 0.- al eS (.o — t Bldg. no.: Suite no.: Lot: 'Block: (Subdivision: 'Tax map /tax lot/account no.: Project name: S i `p'S ^ ,n �'` Description and location of work on premises/special conditions: 1] eo - �N �o 4 b 1 I/ OWNER •= FOR SPECIALINFORMATION, USE CHECKLIST k Name: _S) `' , >o `aL (Floodplain, septic capacity, solar, etc.) 7 Y{ Mailing Address: / (S305 S ) V // • S 1 & 2 family dwelling: i ' , ■ City: ,0), WI� 'State: ZIP: Valuation of work $ i Phone: (Fax: 1E-mail: . No. of bedrooms/baths `` Owner's representative: Total number of floors Phone: Fax: E -mail: New dwelling area (sq. ft.) __.._ - ;_._. � _..Y,. --APPLICANT - _ - Garage/carport area (sq. ft.) ' ame: ---771"---771"'s �.. ty1/.,.2 ■ Cell ' a'c T 3, -9255 Covered porch area (sq. ft.) 4-C Mailin address: ,(7 a ))J ) . Deck area (sq. ft.) _.SZ'D )O . ' N. k, . City: \ IP: • Wal O, er st cure area (sq. ft.) _/ Phone: Zy I -7•2S S Fax: 249 - 4 0 E -mail: AAL $ vvs 4 e 4r. ' mmercial/industriallmulti- family: CONTRACTOR Valuation of work $ Business n 70 V mil-. L Existing bldg. area (sq. ft.) W e: � e Jcz New bldg. area (sq. ft.) City : - I� /Z / � City: � o(�) +✓� I State�'�/ 1 ZIP Number of stories Type of construction Phone;,S.) 3 2_ 1 Fax: E -mail: Occupancy group(s): Existing: CCB no.: � ' � -- / a y " ! New: City /metro lic. no.: Notice: All contractors and subcontractors are required to be licensed with the Oregon Construction Contractors Board under Name: , — rt eYt provisions of ORS 701 and may be required to be licensed iri the Address J�. , /0014'L jurisdiction where work is being performed. If the applicant is City: ti) :tate:S ZIP: - /7z9 6' exempt from licensing, the following reason applies: Contact person: — FY' Plan no.: - 2SS Phone: Z111 -1 Fax: Z.:3 2 E -mail: Name: Contact person: Fees due upon application $ Address: Date received: City: 'State: Amount received $ Phone: IFax• .. I ail: Please refer to fee schedule. I hereby certify I have read and examined`this application and the Not all jurisdictions accept credit cards, please call jurisdiction for more Information. attached checklist. All provisions of laws and ordinances governing this ❑ Visa ❑ MasterCard work will be complie het ified herein or not. 1 /) Credit card number / / l Expires dit Authorized signature: -,J2._ Date: �� Name of cardholder as shown on credit card Print name: ,( r �' f� ' Cardholder signature $ Amount Notice: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. 440-4613 (6/00 /COM) II ,fiF ' CYO. 5---. One- and Two - Family Dwelling • • 621. �,� Building Permit Application Checklist Reference no.: Associated permits: City of Tigard City of Tigard O Electrical O Plumbing ❑ Mechanical Address: 13125 SW Hall Blvd, Tigard, OR 97223 0 Other: Phone: (503) 639 -4171 Fax: (503) 598 -1960 THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW , Yes No N/A I Land use actions completed. See jurisdiction criteria for concurrent reviews. 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. 3 Verification of approved plat/lot. 4 Fire district approval required. 5 Septic system permit or authorization for remodel. Existing system capacity 6 Sewer permit. 7 Water district approval. 8 Soils report. Must carry original applicable stamp and signature on file or with application. 9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch -basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells/septic systems; utility locations; direction indicator, lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing - member sizes and spacing such as floor beams, headers, joists, sub -floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and /or lateral analysis plans. Must indicate details and locations; for non - prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors /roof assemblies, indicating member sizing, spacing, and bearing locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists over 10 feet long and/or any beam/joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas - piping schematic is required for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or architect licensed in Oregon and shall be shown to be applicable to the project under review. JURISDICTIONAL SPECIFICS 23 Five (5) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". 24 Two (2) sets each are required for Items 16, 19, 20 & 22 above. 25 Building plans shall not contain red lines or tape -ons. 26 No rolled, reversed or mirrored building plans will be accepted. 27 28 Checklist must be completed before plan review start date. Minor changes or notes on submitted plans may be in blue or black ink. Red ink is reserved for department use only. 440.4614 (6/00 /COM) CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Line: 639 - 4171 Date Requested / AM PM BLD Location / Co 30 c W 4rJ` SS MEC Contact Person Ph 7 5Z) 0-( 84 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: 1; OQ,0 Foundation C1-11--6 / FPS Ftg Drain SGN Crawl Drain Inspection Notes Slab /, I '"-' !� SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing I e,es Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: dalg _BART FAIL L NG Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date l ` U Inspector E Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.