Loading...
Specifications •r 93-75 it/ ts mecaDO5— 00( HBAW SERIES . ° ,d,;‘).,7170 • ,.y d • • I Li BELT DRIVE HORIZONTAL CHILLED WATER BLOWER COIL UNITS Nominal Sizes 2 thru 20Ton MAGIC AIRE HBAW SERIES FAN COILS ARE ETLC L LISTED IN ACCORDANCE WITH UL 1995 ,„.�►; AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY, LP 501 Galveston St. • Wichita FaIIs,Texas 76301 • 940-397-2100 • Fax 940 -397 -2166 HBAW 2.0 www. magicaire.com PI 01103 5M • A4e • ENGINEERING SPECIFICATIONS Contractor shall furnish and install high quality air handling Fan Wheels shall be double width, double inlet, forward units as indicated on plans. Sizes and capacities shall be shown curved, centrifugal type.They shall be statically and dynami- in the Unit Schedule included on the drawings.All units shall tally balanced for smooth, quiet operation.The housing shall be the products of Magic Aire with the ETL safety listing. be constructed of heavy gauge steel with die - formed inlet cones. The bearings shall be self aligning, sealed cartridge, Cabinets shall be fabricated of LFQ (min) steel. External permanently lubricated ball bearings that are rubber mounted parts are to be made with polyurethane based powder coated and shall provide dependable fan operation for an average A60 galvanealed, while internal parts are to be built from life of 200,000 hours. The fan shaft shall be solid cold rolled G90 galvanized steel. Units shall pass 500 hour salt spray steel designed such that its operating speed is below its first test as described in ASTM B -117. Large access panels shall critical speed. be provided to permit full access to internal components. The structural integrity of the cabinets shall remain unaf- Motors and Drives shall be belt drive, standard duty, 1725 fected by the removal of any or all access panels. RPM, open, drip -proof construction. Single phase motors shall be provided with resilient mount and automatic reset ther- Insulation shall be 1 inch dual density, blanket -type made mal protection. Drive shall be of theV -belt type.Variable pitch from borosilicate glass fibers bonded with a thermosetting motor sheaves are to be furnished for ease and accuracy in resin. Insulation shall include antimicrobial coating. Insula- balancing the system and adjusting the required air volume. tion shall be one and - one -half pound density providing ef- The motors are to be bolted to an adjustable platform to fective acoustical and thermal control, fire safety, and resis- facilitate belt tension and alignment.The blower sheave shall Lance to air erosion. be cast iron single groove with split tapered bushing that is keyed to the blower shaft. Coils shall be of the staggered tube type constructed with seamless copper tubes and headers, and deep corrugated Filters are to be 2" disposable type. They shall be center aluminum fins with straight edges. Manufacturer shall supply loading with an 85% arrestance efficiency.The filters shall be full depth collars, drawn in the fin stock to provide accurate included in the units as an integral part of the cabinet with control of fin spacing and completely cover the copper tubes easy access provided by the manufacturer. to lengthen coil life. The tubes are to be mechanically ex- panded into the fins for a permanent primary to secondary Mixing Boxes shall include low leak damper assemblies con - surface bond, assuring maximum heat transfer efficiency.The strutted of welded steel channel frames with 18 gauge galva- coils are to be tested at 500 PSI for operation at 400 PSI nized steel blades, die formed stiffeners and full blade stop. gauge.The coils provided shall be suitable for the application Stainless steel side seals and vinyl blade seals to reduce leak - and comply with the required performance as described in age shall be standard. All hardware shall be zinc plated with the Unit Schedule. brass pivot points and bronze oilite bearings. Shafts shall be corrosion resistant steel. Mixing box shall be fully insulated Drainpans shall be sloped in two planes for positive drain- with manufacturers standard insulation. age and shall be fabricated of heavy gauge Type 304 stainless steel. Page 2 HBAW 2.0 HBAW Series STANDARD FEATURES • Controls (i.e. contactor, starter, or transformer /fan relay) not included in standard product. Only ODP, single and three phase motors on 2 -5 Ton units are factory -wired to 1 -box. All other motors require field wiring to J -box located on side of unit cabinet. • 24 HBAW through 60 HBAW have 3/8" NC thread inserts (7/8" in from corners) in each corner of top panel for easy suspension. 90 HBAW through 240 HBAW have 7/8" knockouts in each corner of top and bottom panels for suspension rods to pass through. 7/8" knockouts are 3-1/2" in from corners — both on center line. • Chilled water (optional hot water or steam) coil stubouts, electrical and drain connections are standard right hand looking at filters. Optional left hand connections available (see price sheets for additional charge). • Stocked Optional Accessories: • 1 Row Hot Water Heating Coil (24 -60 only) — Specify reheat or preheat • 2 Row Hot Water Heating Coil • MB Series Mixing Boxes • Mixing Box Controls (Field Install and Wire) • Four Way Deflection Discharge Grille Plenum • Return Air Grille • Unit Spring Isolators • 2" Pleated Filters • Non -Stock Options: • Special Insulation • Steam Coils (See Steam Brochure) • Bottom Access (24 -60 only) • Electric Heat • Double Wall Construction • Face & Bypass Damper (See separate brochure for details) Page 3 HBAW 2.0 Product Description MODEL NUMBER IDENTIFICATION 24 H B A W 6 NOMINAL MBH CAPACITY J TYPE CABINET (HORIZONTAL) TYPE BLOWER (BELT) DESIGN CODE *TYPE COIL (W = WATER X = DIRECT EXPANSION COIL ROWS Specifications WATER COIL CONNECTION SIZE (OD SWT) MODEL NOM. FILTER TONS SHIP SHIP SHIP 4 ROW WT WT ROW WT 2 ROW 1 ROW , 24 HBA 2 3/4" 145 3/4" 156 5/8" 5/8" 13 16 X 25 36 HBA 3 3/4" 171 7/8" 190 7/8" 5/8" 18 1 -16 X 32 48 HBA 4 7/8" 200 1 1/8" 227 7/8" 7/8" 25 2 -16 X 20 60 HBA 5 1 1/8" 244 1 1/8" 263 1 1/8" 7/8" 30 2 -20 X 20 2 -16 X 25 90 HBA 7.5 1 1/8" 457 1 3/8" 475 1 1/8" N/A 41 1 -20 X 25 120 HBA 10 1 3/8" 512 1 5/8" 547 1 1/8" N/A 53 3 -16 X 32 2 -20 X 25 180 HBA 15 1 3/8" 700 1 5/8" 787 1 3/8" N/A 86 4 -20 X 20 2 -16 X 20 2 -16 X 25 2 -20 X 20 240 HBA 20 2 -1 5/8" 775 2 -1 5/8" 855 2 -1 1/8" N/A 106 2 -20 X 25 "'Coil only. Specifications subject to change without notice due to continuing effort to improve our product. Page 4 HBAW 2.0 • • di BELT DRIVE HORIZONTAL CHILLED "' WATER BLOWER COIL UNITS H CAPPED - USED ONLY IN LH APPLICATIONS D lic A , D k B 1 A I f , A -- r' 1 - \. Ell ..) HW CW • - O . 4X4 AIR OUTLET ACCESS PANEL �_ Electrical G ; �O (BOTH SIDES) Junction • Box C FLOW HW CW SUPPLY - RH H : A l cw C L F ..._I< E- -1 r -®V v - 3/4" FPT DRAIN FILTER ACCESS 0 Chilled Water Coil Connection FRONT (BOTH SIDES) • Hot Water Coil Connection RIGHT SIDE (Preheat Position Shown, Reheat Available) 1.‹ K • • • r U 44.: I I I •••••• L FILTER :;:;:;: I See Note(S) 180 I ...pp • • • ..�•• S 240 I •• 7 DUAL BLOWER UNITS (180/240) - REAR .. „,. ► S: k I t1 1 0 1 ti BLOWER RETURN MODEL UNIT OPENING DUCT OUTLET CONN. A B C D E H F G K L 24 HBA 37.00 27.00 18.00 1 9.13 1.00 8.75 10.88 18.00 16.00 36 HBA 37.00 36.50 18.00 1 12.09 1.00 12.31 10.88 27.50 16.00 48 HBA 42.00 38.00 22.00 1 14.25 1.00 9.50 14.00 29.00 20.00 60 HBA 42.00 45.00 22.00 1 16.00 1.00 13.00 14.00 36.00 20.00 90 HBA 52.50 54.00 27.00 1 20.38 1.00 13.25 16.75 45.00 25.00 120 HBA 52.50 57.00 34.00 1 21.88 8.50 13.25 16.75 48.00 32.00 180 HBA 57.50 67.13 42.00 1 () 7.00 (2) 16.07 (2) 15.88 57.75 40.25 240 HBA 57.50 72.00 47.00 1 (2) 11.88 (2) 16.07 (2) 15.88 66.00 45.00 (0 Blower opening 7" down from top of unit. Looking at discharge 14 -3/8 left side, 11 - 3/8 center and 8 - 3/8 right side. (2) Blower opening 11 -7/8 down from top of unit. Looking at discharge 14 -3/16 left side, 11 -3/8 center and 13 - 5/16 right side. Page 5 HBAW 2.0 4 • • • ,.,, STUBOUT DIMENSIONS RETURN (CW OR HW PREHEAT) RETURN (24 THROUGH 60 HBH -1 IN PREHEAT) RETURN (24 THROUGH 60 HBH -1 IN REHEAT) RETURN .% BA (CW) RETURN (HW REHEAT) B Oe iL A ..1. 1.125 ' • °'! • n. .. • 0 + SUPPLY (CW OR HW REHEAT) 0 C D E F G H I SUPPLY (CW) SUPPLY (HW PREHEAT) •. . . . 000 RETURN 34.625 c5A SUPPLY 29.000 240 -HBAW (only) 00 0 RETURN 13.250 • w • SUPPLY Pr o. 7.500 I• 1 1.200 --- • 1 r( n 0 C D E F G H I Page 6 HBAW 2.0 • 4 ,-=, 2THROUGH 2OTON HBAW AND HBH COIL STUBOUT DIMENSIONAL DATA UNIT SIZE A B BA C D E F G H I • 24/36 HBAW -4 5.500 9.750 - 4.400 - 7.000 - - 9.500 - 24/36 HBAW -4-1 5.500 9.750 14.000 4.400 - 7.000 - - 9.500 10.500 24/36 HBAW -4-2 5.500 9.750 - 4.400 - 7.000 - 9.375 9.500 10.500 24/36 HBAW -1 -4 5.500 9.750 - - 5.400 - 7.875 - 9.500 10.500 24/36 HBAW -2 -4 5.500 9.750 14.000 4.400 5.400 - 7.875 - 9.500 10.500 24/36 HBAW -6 5.500 9.750 - 4.400 - 8.750 - - 9.500 - 24/36 HBAW -6 -1 5.500 9.750 14.000 4.400 - 8.750 - - 9.500 12.250 24/36 HBAW -6 -2 5.500 9.750 - 4.400 - 8.750 - 11.125 9.500 12.250 24/36 HBAW -1 -6 5.500 9.750 14.000 - 5.400 - 7.875 - 9.500 12.250 24/36 HBAW -2 -6 5.500 9.750 - 4.400 5.400 - 7.875 - 9.500 12.250 48/60 HBAW -4 5.500 11.750 - 4.400 - 7.000 - - 9.500 - 48/60 HBAW -4 -1 5.500 11.750 18.000 4.400 - 7.000 - - 9.500 10.500 48/60 HBAW -4-2 5.500 11.750 - 4.400 - 7.000 - 9.375 9.500 10.500 48/60 HBAW -1 -4 5.500 11.750 18.000 - 5.400 - 7.875 - 9.500 10.500 48/60 HBAW -2-4 5.500 11.750 - 4.400 5.400 7.875 - 9.500 10.500 48/60 HBAW -6 5.500 11.750 - 4.400 - 8.750 - - 9.500 - 48/60 HBAW -6 -1 5.500 11.750 18.000 4.400 - 8.750 - - 9.500 12.250 48/60 HBAW -6 -2 5.500 11.750 - 4.400 - 8.750 - 11.125 9.500 12.250 48/60 HBAW -1 -6 5.500 11.750 18.000 - 5.400 - 7.875 - 9.500 12.250 48/60 HBAW -2 -6 5.500 11.750 - 4.400 5.400 - 7.875 - 9.500 12.250 90 HBAW -4 5.500 14.250 - 4.400 - 7.750 - - 10.625 - 90 HBAW -4-2 5.500 14.250 - 4.400 - 7.750 - 10.375 10.625 11.375 90 HBAW -2 -4 5.500 14.250 - 4.400 5.400 - 8.188 - 10.625 11.375 90 HBAW -6 5.500 14.250 - 4.400 - 9.875 - - 10.625 - 90 HBAW -6 -2 5.500 14.250 - 4.400 - 9.875 - 12.500 10.625 13.500 90 HBAW -2 -6 5.500 14.250 - 4.400 5.400 - 8.188 - 10.625 13.500 120 HBAW -4 4.750 17.500 - 4.400 - 7.750 - - 10.625 - 120 HBAW -4 -2 4.750 17.500 - 4.400 - 8.125 - 10.375 10.625 11.375 120 HBAW -2-4 4.750 17.500 - 4.400 5.400 - 8.188 - 10.625 11.375 120 HBAW -6 4.750 17.500 - 4.400 - 9.875 - - 10.625 - 120 HBAW -6 -2 4.750 17.500 - 4.400 s - 9.875 - 12.500 10.625 13.500 120 HBAW -2 -6 4.750 17.500 - 4.400 5.400 - 8.188 - 10.625 13.500 180 HBAW -4 6.800 21.500 - 4.400 8.625 - - 11.700 - 180 HBAW -4 -2 6.800 21.500 - 4.400 - 8.625 - 11.375 11.700 12.375 180 HBAW -2 -4 6.800 21.500 - 4.400 6.500 - 9.125 - 11.700 12.375 180 HBAW -6 6.800 21.500 - 4.400 - 10.800 - - 11.700 - 180 HBAW -6 -2 6.800 21.500 - 4.400 - 10.800 - 13.500 11.700 14.500 180 HBAW -2 -6 6.800 21.500 - 4.400 6.500 - 9.125 - 11.700 14.500 240 HBAW -4 - - - 5.500 6.625 8.750 - - 11.750 - 240 HBAW -4-2 - - - 5.500 6.625 8.750 - 11.375 11.750 12.500 240 HBAW -2 -4 - - - 5.500 6.625 - 9.250 - 11.750 12.500 240 HBAW -6 - - - 5.500 6.625 11.000 - - 11.750 - 240 HBAW -6 -2 - - - 5.500 6.625 11.000 - 13.500 11.750 14.625 240 HBAW -2 -6 - - - 5.500 6.625 - 9.250 - 11.750 14.625 Page 7 HBAW 2.0 iii ia 9„:„.... d.o FAN PERFORMANCE CALCULATED FAN DATA MODEL INTER cFM .25' ESP .50' ESP .75' ESP 1.00' ESP 1.25' ESP 1.50' ESP S.P. RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP .20 600 786 .11 975 .15 1160 .22 1320 .29 1470 .38 1600 .43 .26 700 835 .13 1006 .20 1172 .26 1321 .32 1471 .40 1612 .48 24 HBAW-4 .31 800 897 .19 1052 .24 1201 .31 1341 .38 1483 .44 1616 .54 .38 900 957 .23 1110 .30 1239 .35 1365 .43 1489 .49 1619 .59 .45 1000 1018 .28 1161 .35 1291 .43 1406 .49 1517 .58 1627 .65 .20 900 814 .15 906 .21 1051 .32 1313 .41 1468 .54 1586 .63 .27 1050 855 .21 989 .27 1112 .34 1391 .50 1504 .60 1576 .68 36 HBAW -4 .33 1200 865 .25 1009 .34 1174 .43 1411 .56 1576 .68 1679 .82 .39 1350 1040 .36 1195 .45 1349 .58 1463 .65 1576 .77 1689 .89 .48 1500 1082 .44 1241 .56 1380 .68 1499 .78 1617 .90 1710 1.03 .32 1200 697 .27 809 .33 916 .43 1023 .52 1113 .62 1200 .70 .40 1400 764 .35 864 .44 962 .54 1071 .66 1145 .74 1225 .85 48 HBAW -4 .50 1600 838 .49 931 .61 1020 .70 1103 .78 1179 .92 1274 1.05 .61 1800 915 .64 996 .77 1077 .89 1156 .99 1228 1.11 1290 1.23 .74 2000 992 .87 1061 .98 1134 1.08 1203 1.23 1280 1.34 1343 1.47 .28 1500 630 .27 751 .37 857 .46 953 .58 1053 .68 1148 .80 .36 1750 682 .37 793 .47 890 .60 983 .69 1074 .81 1155 .95 60 HBAW -4 .44 2000 736 .49 839 .61 934 .75 1019 .88 1100 .98 1176 1.12 .54 2250 802 .68 893 .79 980 .94 1058 1.07 1134 1.21 1208 1.34 .62 2500 854 .84 941 .99 1025 1.14 1103 1.28 1173 1.43 1241 1.60 .26 2250 543 .40 634 .52 723 .65 803 .79 882 .94 948 1.08 .33 2625 584 .56 679 .73 758 .87 838 1.02 903 1.17 972 1.33 90 HBAW -4 .40 3000 641 .78 724 .97 794 1.11 876 1.31 935 1.47 998 1.63 .50 3375 694 1.05 769 1,25 842 1.44 906 1.61 969 1.80 1030 2.01 .59 3750 749 1.37 820 1.59 886 1.80 947 2.00 1009 2.21 1066 2.43 .28 3000 610 .68 695 .84 771 .99 847 1.15 925 1.38 991 1.51 .35 3500 680 .99 750 1.15 821 1.37 886 1.53 954 1.74 1020 1.96 120 HBAW -4 .44 4000 743 1.39 811 1.69 877 1.91 938 2.13 999 2.36 1057 2.60 .53 4500 812 2.01 879 2.28 939 2.52 993 2.77 1054 3.04 1107 3.19 .63 5000 887 2.70 947 2.89 1003 3.20 1056 3.45 1107 3.74 1159 4.05 ,41 5000 546 1.00 637 1.22 717 1.46 791 1.74 868 2.03 937 2.36 .48 5500 575 1.18 656 1.46 732 1.75 806 2.05 879 2.36 945 2.68 180 HBAW -4 .56 6000 606 1.43 684 1.74 755 2.06 824 2.37 892 2.67 952 2.98 .64 6500 636 1.72 705 2.03 776 2.36 842 2.68 904 2.98 968 3.44 .73 7000 688 2.08 738 2.39 800 2.70 865 3.03 926 3.46 985 3.89 .38 7000 564 1.60 640 1.96 712 2.27 776 2.58 839 2.90 903 3.29 .42 7500 587 1.89 660 2.21 728 2.52 790 2.83 850 3.25 910 3.68 240 HBAW -4 .48 8000 614 2.19 686 2.54 749 2.89 809 3.27 867 3.68 926 4.21 .54 8500 642 2.54 702 2.90 769 3.36 827 3.86 884 4.36 941 4.86 .60 9000 672 2.92 733 3.39 791 3.87 846 4.36 902 4.84 959 5.44 Available Motors (60 Hz) Select appropriate motor horsepower HORSE POWER VOLTAGE /PHASE from pages 8 -11. 1/4, 1/3 115/1 Split Phase When ordering, specify HP - voltage/ phase - CFM @ESP. 1/4, 1/3, 1/2, 3/4, 1, 1 1/2, 2 115/208 -230/1 1/4, 1/3, 1/2, 3/4 115/1 2 SPD Consult List Price Pages for motor installation and options. 1/4, 1/3, 1/2, 3/4 230/1 2 SPD For motors not listed, contact factory. 1/4, 1/3, 1/2, 3/4, 1, 1 1/2 277/1 Only ODP, single and three phase 1/3, 1/2, 3/4, 1, 1 1/2, 2, 3, 5, 7 1/2, 10 208 - 230/460/3 motors on 2 -5 Ton units are factory- . wired to 1 -box. All others require field wiring to 1 -box on side of unit cabinet. Page 8 HBAW 2.0 4 • • FAN PERFORMANCE CALCULATED FAN DATA MODEL INTER UM .25* ESP .50" ESP .75" ESP 1.00" ESP 1.25" ESP 1.50' ESP S.P. RPM BFiP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP .23 600 827 .13 1016 .18 1182 .25 1345 .30 1498 .38 1636 .46 .30 700 884 .15 1055 .22 1205 .27 1352 .34 1494 .40 1626 .49 24 HBAW -6 .37 800 939 .20 1094 .26 1237 .31 1375 .39 1509 .47 1634 .55 .45 900 1010 .26 1155 .31 1290 .39 1407 .47 1526 .54 1639 .63 .55 1000 1069 .31 1208 .38 1331 .44 1456 .54 1568 .62 1670 .69 .27 900 881 .19 1066 .27 1302 .39 1438 .48 1563 .67 1685 .69 .35 1050 953 .24 1114 .34 1265 .42 1406 .56 1623 .72 1693 .78 36 HBAW -6 .41 1200 985 .30 1132 .38 1271 .46 1512 .60 1614 .77 1731 .88 .51 1350 1049 .38 1193 .47 1325 .57 1449 .69 1564 .79 1728 .99 .60 1500 1125 .50 1263 .58 1376 .70 1492 .78 1600 .92 1706 1.05 .35 1200 721 .28 830 .36 938 .43 1046 .54 1138 .63 1216 .71 .45 1400 784 .37 894 .46 995 .56 1077 .65 1174 .78 1261 .88 48 HBAW -6 .57 1600 870 .52 964 .61 1052 .73 1130 .82 1208 .94 1282 1.04 .69 1800 936 .67 1031 .78 1111 .92 1192 1.02 1263 1.14 1332 1.27 .81 2000 1014 .87 1103 1.00 1177 1.12 1255 1.28 1323 1.38 1388 1.55 .30 1500 671 .29 796 .39 898 .49 1000 .61 1102 .77 1212 .89 .39 1750 728 .40 839 .50 940 .63 1028 .75 1120 .88 1202 .99 60 HBAW -6 .48 2000 790 .54 890 .66 979 .77 1064 .92 1146 1.04 1226 1.16 .58 2250 849 .70 939 .83 1024 .98 1117 1.11 1186 1.28 1257 1.40 .69 2500 919 .92 1001 1.06 1083 1.21 1154 1.36 1230 1.52 1294 1.66 .31 2250 572 .43 665 .56 753 .72 828 .84 905 .99 975 1.14 .39 2625 629 .63 706 .76 792 .93 863 1.07 933 1.25 997 1.41 90 HBAW -6 .49 3000 674 .83 759 1.02 830 1.18 902 1.37 967 1.55 1031 1.73 .60 3375 730 1.13 806 1.33 882 1.53 946 1.74 1007 1.94 1064 2.13 .72 3750 795 1.50 863 1.73 931 1.94 987 2.14 1049 2.38 1107 2.62 .31 3000 638 .70 720 .92 801 1.07 878 1.21 957 1.44 1018 1.62 .40 3500 709 1.03 783 1.25 851 1.42 921 1.64 981 1.80 1053 2.05 120 HBAW -6 .50 4000 786 1.53 852 1.76 915 1.96 972 2.17 1035 2.38 1092 2.64 .61 4500 857 2.09 916 2.34 975 2.65 1033 2.85 1093 3.10 1146 3.37 .73 5000 925 2.87 979 3.13 1038 3.41 1100 3.77 1145 4.02 1201 4.35 .43 5000 550 1.00 643 1.24 721 1.50 800 1.78 875 2.06 945 2.40 .51 5500 585 1.20 667 1.50 742 1.80 814 2.01 885 2.42 950 2.76 180 HBAW -6 .60 6000 618 1.46 700 1.78 766 2.10 835 2.40 900 2.70 965 3.05 .69 6500 650 1.79 727 2.12 794 2.41 855 2.84 920 3.04 982 3.49 .79 7000 688 2.10 754 2.46 817 2.78 880 3.14 940 3.57 1000 4.00 .40 7000 571 1.62 647 1.98 718 2.32 782 2.60 845 2.92 907 3.32 .45 1500 597 1.92 669 2.26 735 2.58 798 2.92 857 3.32 917 3.74 240 HBAW -6 .51 8000 622 2.24 694 2.58 756 2.92 816 3.32 875 3.74 933 4.24 .57 8500 650 2.58 717 2.94 776 3.34 834 3.76 891 4.24 948 4.86 .62 9000 676 2.96 737 3.34 795 3.74 851 4.20 907 4.84 964 5.48 Full -Load Currents in Amperes, Single Phase Alternating- Current Motors. The following values of full -load currents are for motors running at usual speeds and motors with normal torque characteristics. Motors built for especially low speeds or high torques may have higher full -load currents, and multi -speed motors will have full -load current varying with speed, in which case, the nameplate current rating shall be used. The voltages listed are rated motor voltages.The currents listed shall be permitted for system voltage ranges of 110 to 120 and 220 to 240 volts. HORSEPOWER 115 volts 200 volts 208 volts 230 volts 1/4 5.8 3.3 3.2 2.9 1/3 7.2 4.1 4.0 3.6 1/2 9.8 5.6 5.4 4.9 3/4 13.8 7.9 7.6 6.9 1 16 9.2 8.8 8 1.5 20 11.5 11 10 2 24 13.8 13.2 12 'Values from NEC Handbook 1999 Edition, actual motor nameplate amps may vary. Page 10 HBAW 2.0 CHILLED WATER COOLING CAPACITIES 36- HBAW -4 (4 ROW COIL) 85 degF 08/71 deg.F WB 80 deg.F DB/67 degF WB 75 degF 06/63 deg.F WB Ent GPM PO CFM TTL SENS LVG AIR Deg TTL SENS LVG AIR Deg TTL SENS LVG AIR Deg Wtr FT. MBH MBH DB WB F MBH MBH DB WB F MBH MBH DB WB F 900 28.2 20.6 63.7 62.1 59.7 24.0 19.1 60.4 58.7 57.0 20.0 17.2 57.3 55.5 54.6 3.2 1.20 1200 30.6 24.2 66.3 63.9 61.2 26.2 22.2 62.8 60.3 58.4 22.2 20.0 59.5 56.8 55.9 1500 32.4 27.2 68.2 65.0 62.4 28.0 25.0 64.6 61.4 59.5 22.4 22.0 61.4 58.0 56.1 900 41.0 25.4 58.8 57.4 52.3 34.0 23.2 56.2 54.8 50.5 27.8 20.6 53.7 52.3 49.0 42 8.0 6.70 1200 46.0 30.0 61.9 59.9 53.5 38.0 27.4 58.9 56.9 51.6 31.2 24.6 56.0 54.1 49.8 1500 49.5 33.8 64.2 61.5 54.4 41.5 31.0 60.9 58.4 52.4 33.8 27.8 57.8 55.4 50.5 900 45.5 27.4 56.9 55.6 49.1 37.5 24.8 54.6 53.2 30.6 22.0 52.3 51.0 46.8 12.8 16.50 1200 52.0 32.4 60.1 58.1 50.2 43.0 29.4 57.4 55.4 48.8 35.2 26.4 54.7 52.9 47.5 1500 57.0 36.6 62.5 59.9 50.9 47.5 33.2 59.5 57.0 49.4 38.5 30.0 56.5 54.2 48.1 900 26.0 19.9 64.6 62.8 61.3 21.8 61.3 59.5 58.7 18.1 16.3 58.3 56.2 56.4 3.2 1.20 1200 28.4 23.4 67.0 64.4 62.8 24.0 21.2 63.6 60.9 60.1 19.0 18.7 60.6 57.8 56.9 1500 30.2 26.2 68.8 65.4 63.9 25.8 23.4 65.5 61.8 61.2 20.6 20.2 62.5 58.5 57.9 900 37.4 24.2 60.2 58.8 54.4 30.6 21.8 57.6 56.2 52.7 24.2 19.3 55.2 53.7 51.1 45 8.0 6.70 1200 41.5 28.4 63.1 60.9 55.5 34.4 25.8 60.1 58.0 53.6 27.4 23.0 57.3 55.3 51.9 1500 45.0 32.2 65.1 62.4 56.3 37.2 29.4 61.9 59.3 54.3 _ 30.0 26.2 58.9 56.3 52.5 900 41.5 25.6 58.6 57.2 51.5 33.8 23.0 56.3 54.9 50.3 26.8 20.4 54.1 52.7 49.2 12.8 16.40 1200 47.0 30.4 61.5 59.5 52.4 38.5 27.6 58.8 56.8 51.1 30.6 24.4 56.2 54.3 49.8 1500 51.5 34.6 63.7 61.1 53.1 42.5 _31.4 60.7 58.2 51.6 33.6 27.8 57.8 55.4 50.3 900 23.8 19.1 65.4 63.6 62.9 19.8 17.2 62.3 60.3 60.4 15.2 15.0 59.6 57.4 57.5 3.2 1.20 1200 26.2 22.2 67.8 65.0 64.4 22.0 20.0 64.6 61.5 61.8 17.2 16.9 62.0 58.3 58.8 1500 28.0 25.0 69.6 65.9 65.5 22.2 21.8 66.5 62.6 61.9 18.7 18.3 63.7 58.9 59.7 900 33.6 22.6 61.7 60.1 56.4 27.0 20.4 59.1 57.6 54.8 20.8 17.8 56.7 55.2 53.2 48 8.0 6.60 1200 37.6 27.0 64.2 62.1 57.4 30.2 24.2 61.4 59.2 55.6 23.8 21.2 58.6 56.3 54.0 1 40.5 30.6 66.1 63.4 58.2 33.0 27.6 63.0 60.3 56.3_ 26.4 24.4 60.0 57.1 54.6 900 37.2 24.0 60.3 58.8 53.8 29.8 21.4 58.0 56.5 52.7 22.6 18.7 55.8 54.4 51.6 12.8 16.40 1200 42.5 28.6 62.9 60.8 54.6 34.0 25.6 60.2 58.2 53.3 26.0 22.4 57.7 55.7 52.1 _ 1500 _ 46.0 32.6 64.9 62.2 _ 55.3 37.2 _29.4 61.9 59.4 53.8, _ 28.8_ 25.6 59.2 _ 56.6 52.5 36- HBAW -6 (6 ROW COIL) 85 degF DB /71 deg.F W8 80 deg.F D8/67 degF WB 75 degF 08/63 deg.F WB Ent GPM PD CFM TTL SENS LVG AIR Deg TTL SENS LVG AIR Deg TTL SENS LVG AIR Deg Wtr FT. MBH MBH 08 W8 F MBH MBH DDB WB F MBH MEW D8 W8 F 900 28.2 21.4 62.9 62.1 70.3 24.6 20.0 59.5 58.5 66.7 21.2 18.2 56.3 55.0 63.3 2.0 0.60 1200 30.6 25.2 65.5 63.8 72.8 26.8 23.2 62.1 60.2 68.9 22.8 20.6 59.1 56.6 65.0 1500 32.2 28.0 67.7 65.1 74.3 28.0 _25.2 64.5 61.4 70.0 22.0 21.6 61.7 58.2 64.1 900 39.5 26.0 58.3 57.8 61.9 33.4 23.8 55.6 55.0 58.8 27.8 21.4 52.9 52.2 56.0 42 4.0 2.10 1200 44.0 30.8 61.3 60.4 64.1 37.4 28.2 58.2 57.2 60.8 31.4 25.6 55.2 54.0 57.8 1500 47.5 35.2 63.3 62.0 65.8 40.5 32.4 60.0 58.6 62.3 34.2 29.4 56.9 55.3 59.2 900 53.0 31.4 '52.8 52.4 53.1 44.0 28.4 50.9 50.4 51.3 36.0 25.2 49.1 48.6 49.5 9.6 10.90 1200 61.5 37.6 56.1 55.3 54.9 51.5 34.2 53.7 52.9 52.7 41.5 30.4 51.5 50.7 50.7 1500 67.0 42.5 58.6 57.5 56.2 56.5 39.0 55.9 54.8 53.9 46.5 35.2 53.3 52.2 51.7 900 26.2 20.6 63.8 62.8 71.2 22.6 60.5 59.2 67.8 19.3 '16.9 57.6 55.8 64.4 2.0 0.60 1200 28.6 24.2 66.4 64.4 73.7 24.6 21.6 63.3 60.8 69.6 18.8 18.6 60.7 57.8 63.9 1500 30.6 27.0 68.3 65.4 75.7 23.2 22.8 65.9 62.3 68.3 20.0 19.6 62.9 58.6 65.0 900 36.4 24.6 59.7 59.2 63.2 30.4 22.4 56.9 56.3 60.2 25.0 20.2 54.2 53.4 57.5 45 4.0 2.10 1200 40.5 29.4 62.3 61.3 65.3 34.2 27.0 59.2 58.1 62.2 28.4 24.2 56.3 54.9 59.3 1500 43.5 33.8 64.2 62.7 67.0 37.2 30.8 61.0 59.3 63.7 31.2 27.6 58.0 56.0 60.6 900 48.5 29.4 54.8 54.3 55.2 39.5 26.4 52.9 52.4 53.3 31.6 23.2 51.1 50.6 51.6 9.6 10.90 1200 56.0 35.4 57.7 56.9 56.7 46.0 32.0 55.4 54.6 54.6 36.8 28.2 53.2 52.4 52.7 1500 62.0 40.5 60.0 58.9 57.9 51.0 36.8 57.3. 56.2 55.6 , 40.5 32.6 54.9 53.7 53.5 900 24.4 19.8 64.7 63.4 72.4 20.8 17.8 61.7 59.9 68.9 15.4 15.2 59.4 57.3 63.4 2.0 0.60 1200 26.6 22.8 67.4 64.9 74.7 20.0 19.7 64.8 62.0 68.1 16.9 16.6 62.2 58.4 65.0 1500 24.6 24.4 70.0 66.5 72.7 21.2 20.8 67.1 62.8__69.3 18.0 17.7 64.1 59.1 66.0 900 33.0 23.4 60.9 60.3 64.6 27.4 21.2 58.1 57.4 61.8 22.2 18.9 55.6 54.6 59.2 48 4.0 2.10 1200 37.2 28.2 63.3 62.2 66.7 31.2 25.6 60.2 58.9 63.6 25.6 22.6 57.6 55.8 60.8 1500 40.5 32.2 65.1_63.4 68.3 34.2 29.2 62.0 60.0 65.1 25.4 25.0_ 59.6 57.4 60.8 900 44.0 27.6 56.7 56.2 57.2 35.2 24.6 54.8 54.3 55.4 26.8 21.0 53.3 52.7 53.6 9.6 10.80 1200 50.5 33.2 59.4 58.5 58.6 40.5 29.8 57.0 56.2 56.5 31.6 26.0 54.9 54.0 54.6 1500 55.5 58.0 61.4 60.2 59.6 44.5 34.7 58.9 57.6 57.4 _ 35.4 30_4 56.3 55.0 55_4, Page 13 HBAW 2 .0 Discharge Plenum Static Loss DEFLECTION THROW STATIC MODEL/SIE CFM PRESSURE (DEG) (FEET) (I.W.G.) 24 -BHGP 800 0 50 0.034 45 37 0.054 36 -BHGP 1200 0 69 0.054 45 52 0.087 48 -BHGP 1600 0 79 0.053 45 59 0.085 60 -BHGP 2000 0 89 0.053 45 66 0.085 90 -BHGP 3000 0 124 0.090 45 93 0.114 120 -BHGP 4000 0 103 0.097 45 77 0.155 180 -BHGP 6000 0 124 0.090 45 93 0.144 240 -BHGP 8000 0 92 0.062 45 69 0.098 Mixing Box Static Pressure Drop MODEL CFM RANGE S/P 600 CFM .04 24 -MB 800 CFM .07 $ 1000 CFM .08 1 900 CFM .05 36 -MB 1200 CFM .08 1500 CFM .12 1200 CFM .06 48 -MB 1600 CFM .10 2000 CFM .15 1500 CFM .04 60 -MB 2000 CFM .07 2500 CFM .11 2250 CFM .04 90 -MB 3000 CFM .06 3750 CFM .10 3000 CFM .01 120 -MB 4000 CFM .03 5000 CFM .04 5000 CFM .03 180 - 6000 CFM .05 7000 CFM .06 7000 CFM .06 240 8000 CFM .08 9000 CFM .10 Water Volume in Gallons for Hydronic Coils (8.34 # /gailon) MODEL/UNIT MODEL/UNIT HOT WATER COIL HORIZONTAL C/W HORIZONTAL C/W HORIZONTAL 24 HBAW -4 0.55 GAL 24 HBAW -6 0.83 GAL 24 HBH -2 0.31 GAL 36 HBAW -4 0.84 GAL 36 HBAW -6 1.26 GAL 36 HBH -2 0.65 GAL 48 HBAW -4 1.11 GAL 48 HBAW -6 1.66 GAL 48 HBH -2 0.69 GAL 60 HBAW -4 1.38 GAL 60 HBAW -6 2.07 GAL 60 HBH -2 0.86 GAL 90 HBAW -4 2.92 GAL 90 HBAW -6 4.39 GAL 90 HBH -2 1.32 GAL 120 HBAW -4 3.75 GAL 120 HBAW -6 5.63 GAL 120 HBH -2 1.72 GAL 180 HBAW -4 5.25 GAL 180 HBAW -6 7.87 GAL 180 HBH -2 2.62 GAL 240 HBAW -4 6 94 GAL 240 HBAW -6 10.40 GAL 240 HBH -2 3.47 GAL Page 23 HBAW 2.0