Plans RECEIVED „a! , OC T 31 1005 B CITY p T1U DING DI VISION 0005- 6'rZ9 5 79 9,3 Va ° ' a ( FIRE ALARM SUBMITTAL Washington Square Teavana Siemens Job Number 261007 Siemens Project Manager Chuck Neely Siemens Project Engineer Ron Pulioff Date Submitted October 27, 2005 Proprietary document for approval only SIEMENS Siemens Building Technologies, Inc. 3025 S.W. Corbett Ave Portland, OR 97201 Phone: (503) 234 -9995 Fax: (503) 234 -8030 Table of Contents SIEMENS BILL OF MATERIAL & COMPONENT SPECIFICATIONS 4. FUNCTIONAL MATRIX BATTERY CALCULATIONS VOLTAGE DROP CALCULATIONS BILL OF MATERIALS SIEMENS Washington Square Teavana 261007 Fire Alarm System Item Part # Qty Mfg Description 1 FP -11 3 Siemens Fire Print Intelligent Detector 2 DB -11 2 Siemens Dectector Base Standard 3 AD -11XPR 1 Siemens Duct Detector Housing 4 STA -10 1 Siemens Sample Tube 6' 3" - 9' 9" 5 E50- 24MCW -FW 2 Wheelock Speaker /Strobe, Multi- candela, White PROPRIETARY DOCUMENT FOR APPROVAL ONLY 3 10/28/2005 SIEMENS Fire Safety FP -11 FirePrintTM Detector Intelligent Fire Detector for MXL, MXL -IQ, and MXLV Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS • Most Sophisticated "Detector Intelligence" available today • Multi- Criteria fire detection for the price of a photoelectric detector • FirePrintTm Technology to discriminate between deceptive phenomena and an actual fire • Easily programmed to match specific hazard profiles from the control panel • Pre -Alarm reporting based on fire profile selected • Remote sensitivity measurement capability .>t • System logic activation based on any of three inputs from detector (smoke, heat or neural network) • Field cleanable chamber with replaceable chamber parts available • Multi -color detector status LED 0 . , ,. _ . , Iv • Two-wire operation • Compatible with Model DPU or FPI -32 field programmer/tester w • Supports EnviroLINK software based automatic environmental compensation "" • Backward compatible with older MXL systems (Rev. 2 and above) • Optional fully programmable relay base , audible base, and duct housing 0 • UL Listed, ULC Listed, CSFM, FM, NYMEA V� Approved Introduction The FP -11 Intelligent Fire Detector provides the life need for cumbersome, unreliable mechanical program - safety industry with the most highly evolved detection ming methods and reduces installation and service system available today. The FP -11 utilizes advanced costs by electronically programming and testing the detection technology that allows the detector to detector prior to installation. distinguish nonthreatening deceptive phenomena, such as cigarette smoke, from actual fire hazards, while The FP -11 fire detector is compatible with the MXL optimizing detection for the area in which it is in- family of control panels including the MXL, MXLIQ, stalled. No other detection system available today and MXLV. offers a higher level of protection or nuisance The FP -11 detector is Underwriters Laboratories and alarm immunity. The FP -11 uses state -of- the -art Underwriters Laboratories of Canada Listed. microprocessor circuitry with error check, detector self- diagnostics and supervision programs. Description The FP 11 intelligent fire detector is compatible with The FP -11 is a plug -in, two -wire, multi- sensor detector the Siemens Building Technologies, Fire Safety Divi with both photoelectric and thermal inputs and is sion, Model DPU or FPI -32 field programmer /tester, which is a compact, portable, menu - driven accessory compatible with the MXL family of control panel for electronically programming and testing detectors, systems. Each detector consists of a dust resistant, easily and reliably. The DPU or FPI -32 eliminates the field cleanable photo chamber, a solid state CATALOG NUMBER 6175 non - mechanical thermal sensor, microprocessor based evaluating this information with sophisticated electronics with a low- profile plastic cover and base. mathematical formulas, or algorithms, comparing this The FP -11 utilizes state -of- the -art ASIC and surface input to characteristics of both threatening fires and mount technology for maximum reliability. Every FP -11 deceptive phenomena that would "fool" any ordinary fire detector is shipped with a protective dust cover. detector. This technology was developed over years of research and reviewing the results of over 20 years of The FP -11 fire detector utilizes an infrared light fire test data in one of the world's most advanced fire emitting diode (IRLED), and light sensing photodiode. research centers. The results of this research are the Under normal conditions, light transmitted by the LED mathematical models that form the algorithms used in is directed away from the photodiode and scattered FirePrint. No other fire detector has this level of - through the smoke chamber in a controlled pattern. intelligence or this amount of research and develop - The smoke chamber is designed to manage light ment supporting it's design. dissipation and extraneous reflections from dust particles or other non -smoke airborne contaminants in The microprocessor's software can identify and such a way as to maintain stable, consistent detector disregard false input caused by radio frequency (RFI) operation. When smoke enters the detector chamber, and electromagnetic (EMI) interference, and validates light emitted from the IRLED is scattered by the all trouble conditions before annunciating or reporting smoke particles and is received by the photodiode. to the control panel. The FP -11 detector's microproces- The sor uses an integral EEPROM to store the detector's he FP -11 also utilizes a modern, accurate, shock- address and other critical operating parameters which resistant thermistor to sense temperature changes. include the assigned program values for alarm and The "on- board" FirePrint technology allows the trouble thresholds. Communications within the detector to gather smoke and thermal data, and to detector itself and between the FP -11 and the control analyze this information in the detector's "neural panel, or with the FPI -32 field programmer /tester, are network" By comparing data received with the supervised and safeguarded against disruption by common characteristics of fires, or fire fingerprints, reliable, microprocessor based error checking routines. the FP -11 can compare these "Fire Prints" to those of Additionally, the microprocessor supervises all deceptive phenomena that cause other detectors to EEPROM memory locations and provides a high alarm. The advanced FirePrint technology allows the degree of EEPROM failure fault tolerance. FP -11 to accurately determine a true fire hazard from a nonthreatening deceptive phenomena WITHOUT In MXL(V) applications, the FP -11 determines its needing to use alarm delaying verification and confir- operating status to be normal, in alarm, or in trouble mation techniques, which can increase the probability depending on the difference between the alarm of losses due to fire. threshold values stored in the detector's memory and the detector's latest analog measurement. The The FP -11 provides the highest level of detector detector then communicates changes in its status to intelligence available today with a detector /control the control panel. panel link that allows the user to program the detector for the specific hazard profile Detectors are optimized In addition, the MXL(V) control panel will sample the by selecting one of the following applications: value of the FP -11's analog signal over a period of time in order to determine if those values indicate exces- • Office /Retail sive buildup in the photo chamber; if so, the MXL(V) • Lobby will indicate that the particular detector requires • Computer Room maintenance. • Dormitory • Healthcare The FP -11 is listed as a self- testing device. The FP -11's • Parking Garage visible light emitting diode (LED) flashes green every • Utility/Transformer Room 4 seconds to indicate it is communicating with the • Hostile Environment control panel and that it has passed its internal self- • Precious Storage test. Should the detector sense a fault or failure within • Air Duct its systems, the LED will flash amber and the detector • Warehouse /Light Manufacturing will transmit that information to the control panel. A quick visual inspection is sufficient to indicate the The software does the rest; no guessing on detector condition of the detector at any time. If more detailed sensitivities or alarm verification; the control panel information is required, a printed report can be programs the FP -11 detector for the protected area provided from the MXL panel indicating the status without hassle and without confirmation delays. and settings assigned to each individual detector. Once optimized for the hazards in the protected area, the FP -11 provides the best detection you can buy. When the FP -11 moves to the alarm mode, it will flash Should the operator or installer forget to program the amber and transmit that information to the control detector, the FP -11 will revert to a default setting that panel. When the MXL(V) confirms the detectors allows it to operate as a standard photoelectric or condition, the panel will instruct the FP -11 to flash red photothermal detector. and to continue flashing until the system is reset at the control panel. At that same time, any user defined The FP -11's FirePrint technology monitors input from both the photo chamber and the thermal sensor, system alarm functions programmed into the system All FP -11 detectors are approved for operation within are activated. Each FP -11 detector can operate one the UL specified temperature range of 32 to 100 remote alarm indicator, one auxiliary relay, or one degrees F (0 to 38 degrees C). audible base. Detector sensitivity, calibration, and identification are Application Data dynamically supervised by the control panel. Detector Installation of the FP -11 series of fire detectors sensitivity and pre -alarm levels are a function of the requires a two -wire circuit of 18 AWG (minimum) application chosen at the control panel and are thermoplastic fixture wire enclosed in conduit, or 18 controlled by the panel. If an alternate, non - FirePrint AWG limited energy, shielded cable without conduit, mode is selected, then the sensitivity can be changed if permitted by local codes. Field wiring should from the control panel. conform to local and National Electric Codes and the The DPU or FPI -32 Program/Test accessory is used to control panel wiring specifications. program and verify the detector's address. The "T- tapping" is permitted only for Style 4 (Class B) technician selects the accessory's program mode to wiring. enter the desired address. The DPU or FPI -32 auto- matically sets and verifies the address and tests the FP -11 fire detectors can be applied within the maxi - detector. It also allows the user to change the device mum 30 foot center spacing (900 sq. ft. areas) as ID from that of an FP -11 to an older detector ID such as referenced in NFPA 72. This applications guideline is an ILP -1, ILPT-1, ILP -2, ID -60P or ID -60PT to allow for based on ideal conditions, specifically, smooth ceiling easy replacement of older detectors without the need surfaces, minimal air movement, and no physical of reprogramming the control panel. obstructions between potential fire sources and the detector. Do not mount detectors in close proximity The FPI -32 operates on AC power or rechargeable to ventilation or heating and air conditioning outlets. batteries, providing flexibility and convenience in Exposed joints or beamed ceilings may also affect safe programming and testing equipment almost anywhere. spacing limitations for detectors. Should questions When in the test mode, the DPU or FPI -32 will perform arise regarding detector placement, observe NFPA a series of diagnostic tests without altering the 72 guidelines. address or other stored data, allowing technicians to determine if the detector is operating properly. Good fire protection system engineering and common sense dictate how and when fire detectors are The FP -11 fire detector may be installed on the same installed and used. Contact your local Siemens initiating circuit with IL or ID series detectors (Photo- Building Technologies, Fire Safety Division authorized electric, thermal, or ionization), MSI series manual sales outlet whenever you need assistance applying stations, TRI series interfaces, ICP output control FirePrint in unusual applications. Be sure to follow devices, or CZM series of addressable, conventional NFPA guidelines, UL /ULC approved installation zone modules. instructions, which are included with every detector, All FP -11 detectors can be cleaned in the field, when and local codes as for all fire protection equipment. required, by simply removing the detector cover and unsnapping the photo chamber. There is also the Dimensions option of cleaning the interior of the detector with a clean, soft cloth or brush, or replacing the labyrinth and 6' Diameter Base bug screen included in the detector maintenance kit, model DMK -11. The FP -11 uses the low profile surface mounting base, model DB -11. This base mounts on a 4 -inch octagon, T_ square, or a single gang electrical box. The base 2.3" utilizes screw clamp contacts for electrical connections Overall and self- wiping contacts for increased reliability. The �- base can be used with the optional LK -11 detector f.7 ►� • locking kit which contains 50 detector locks and an l ;_ i � installation tool, to prevent unauthorized removal of the detector head. The DB -11 base has integral decora- tive plugs to cover the outer mounting screw holes. The FP -11 is electrically compatible with existing MXL detector accessories including relays, remote lamps, duct housings, and audible bases. With duct housings, a base adapter and new detector housing cover are required (order AD -11 UK upgrade kit). To use existing DB -3S base or audible base, the FP -11 requires a DB- ADPT base adapter. Technical Specifications Current Requirements: Normal 750 Na Alarm 750 Na Operating Temperature: +32 °F (0 °C) to 100 °F (38 °C) per UL 268/268A Humidity: 0 -93% Relative Humidity Non - Condensing Ordering Information Part Model Description Number FP -11 Addressable FirePrint Fire Detector 500- 095112 DB -11 Detector Mounting Base for Series 11 500- 094151 DB -11E Detector Base (Small) 500 - 094151E AD -11P Air Duct Housing for Series 11 500- 095656 AD -11XPR Air Duct Housing w /Relay for Series 11 500- 096062 Intelligent Detector ADBX -11 Audible Base 500- 096181 DB -X11RS Relay Base for Series 11 Intelligent Detectors 500- 096125 RLI -1 Remote (red) alarm indicator- 4" octagon box mount 500- 390673 RLI -2 Remote (red) alarm indicator- single gang box mount 500- 390674 LK -11 Base Locking Kit for Series 11 detectors 500- 695350 DMK -11 Series 11 Maint Kit (replacement labyrinth and bug 500- 695338 bug screen) AD -11UK Air Duct Housing Cover /Adapter Kit 500- 695967 DB -ADPT Base Adapter to DB-3S Base 500- 094187 In Canada Order: FP-11C Addressable FirePrint Fire Detector (ULCI 500- 095112C DB -11C Detector Mounting Base for Series 11 (ULC) 500 - 095687 AD -11PC Air Duct Housing (ULC) 500- 095984 DB- X11RSC Relay Base for Series 11 Intelligent Detectors (ULC) 500 - 0961250 ADBX-11C Audible Base for Series 11 Intelligent Detector IULCI 500-096181C Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 6/03 Brampton, Ontario Siemens Building Technologies Tel: (973) 593 -2600 10M Canada L6T 5E4 g g 12S FAX: (9731 593 -6670 SFS - Tel: (905) 799 -9937 June 2003 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 -9858 superseaessneet°ated7Aa SIEMENS Fire Safety Air Duct Housings-Series 11 ENGINEER AND ARCHITECT SPECIFICATIONS • For Series 11 Detectors C • Relay Models Available • Self contained Model available with On - Board" Power Supply • • Alarm LED Visible from Front t H a.- • Clear Housing Cover for Quick Identification of DetectorType MO IlN • Listed, ULC Listed " =N.ne _ �CSFM, FM, NYMEAApproved w- . « more - Introduction Description The Siemens Building Technologies, Fire Safety Division The Fire Safety air duct housing is uniquely designed to air duct detector housings are designed to be used with use the photoelectric detector. the PE -11 and FP -11 detectors. Designed for installation directly to heating, ventilating and air conditioning duct Sensitivity of PE -11 detectors can be checked by viewing systems, they comply with National Fire Protection the LED or an RSAW -11 or RSAC -11 multicolor remote Association Standard No. 90A. When equipped with lamp. A green flash indicates the detector has passed its photoelectric detectors, these units will signal the self test. Amber indicates a trouble condition, and red presence of hazardous quantities of products of combus- an alarm state. tion or smoke being carried through the duct system. Air FP -11 sensitivity may be viewed from the multicolor duct detectors are not intended to be substituted for open LED on the detector or preferably may be printed area detection. by command on an optional printer from the MXL Air duct housings can be equipped with optional relays. control panel. These relays are utilized to operate any The detector unit employs a cross - sectional sampling supplementary equipment when smoke or particles principle of operation. Inlet sampling tubes are avail- . of combustion are detected. able in four lengths (see table on reverse side). Outlet Note: Most control equipment guarantee only one sampling tubes are one common length. A continuous detector per zone when the detector operated relay cross - sectional sample of air moving through the duct function is critical. The connection of a remote lamp is taken. This averages the effects of laminar flow, and a remote relay per detector is allowed with PXL or stratification or skin effect phenomena occurring in the System 3'"" only, other conventional systems may use duct that could prevent combustion product or smoke either a remote lamp or a relay. (especially in large ducts) from reaching a spot type detector. With the MXL series of control panels, up to 60 detectors per circuit having relays may be used. In addition, the unique design of the sampling chamber The connection of a remote lamp or a remote relay insures uniform sensitivity in air velocities, ranging is allowed for each detector but not both. from a low of 300 feet per minute to as high as 4000 feet per minute. Air duct housings (see Ordering Information) are Underwriters Laboratories, Inc. listed. CATALOG NUMBER 6178 Replaces Catalog Sheet Number 6177 The inlet sampling tube length is determined by the electrically compatible with Series 3 MXL accessories. width of the air duct being protected. The inlet tube 71/2" ______.. .___ 4 nearest to but greater than the duct width should be 19cm10.2cm —' used (see table). The inlet tube can then be trimmed at "'°""""g Holtz. 0/ lye the job site to the exact width of the duct. The outlet i sampling tube for all ducts, irrespective of width, has � a fixed length of approximately 3 inches (7.5 cm) and is ' „ rou _ • supplied with the duct housing. = Duct Width Sampling Tube Model No. 11. I;: i;v r 9' to 1'9"(21 cm to 5l cm) STA -2 • 1'9" to 3'3' 151 cm to 97.5 cm) STA -3 ° ° t 37 to 67(95.5 cm to 187.5 cm) STA-6 - ; "F 67 to 9'9" (187.5 cm to 292.5 cm) STA -10 Greater than 9'9' (292,5 cm) Consult Siemens Are Safety Duct EIBCt�iG31 Confleclon Hole t0 ' When the use of a remote relay is required, order Conduit {Both 5roesi model AD -11PR for conventional systems; AD -11XPR for MXL systems. When required the EAD -3 weather- proof enclosure for Duct Housing is available. — Sampling Tube SelectionTable Shipping Weight P 9 Model Description Lb. Kg. Maintenance of the detector is easily accomplished by AD -11P Series 11 air duct housing with cover for the the removal of the Series 11 duct housing sampling PE -11 and FP -11 detectors 5 2.25 chamber cover. The detector, which plugs into the AD -11PR Series 11 air duct housing with cover for the housing, is easily removed for cleaning by a trained PE -11 photoelectric detector and equipped technician. with remote relay 5 2.25 AD -11XPR Series 11 air duct housing with civer for the All that is necessary for the installation of the air duct FP -11 detector equipped with remote relay 5 2.25 detector is the cutting of three small holes for the SA -11P Series 11 air duct housing with power supply sampling tube installation (template included) and the for ph otoelectric eric self-contained detector unit operation for Pe -11 drilling of four holes for mounting the air duct housing. Upgrade using 7 3.15 mounted in place and connec- AD-11UK Upgrade sit for duct housing or FP 11 detector The unit is then easily p in a series 3 duct housing 1 .45 tion made to the existing wires or terminals if optional STA -2 Sampling Tube. for ducts 9' to 1'9" 1 .45 accessories are utilized. STA -3 Sampling Tube, for ducts 1'9' to 3'3' 2 .9 When using the PE -11 or FP -11 detector in an AD -31 or STA-6 Sampling Tube, for ducts 3'3" to 6'3' 4 1.8 AD-3ILP duct detector housing you must use the STA -10 Sampling Tube, for ducts 6'3' to 9'9'. Sampling Tubes greater than 9'9", consult Siemens AD -11 UK upgrade kit consisting of a detector base Fire Safety 6 3.7 adapter and a new duct housing cover. Any Series 3 RLC -11 Remote Alarm Lamp, ceiling mounted for PE -11 .5 .22 accessories such as remote lamps on relays will also RLW -11 Remote Alarm Lamp, wall mounted for PE -11 .5 .22 have to be updated to PE -11 accessories. The FP -11 is RSAC -11 RemoteTri -color LED, ceiling mounted for PE -11 .5 .22 RSAW -11 Remote Tri-color LED, wall mounted for PE -11 .5 .22 PE -11 Conventional Photelectric Detector 1 .45 FP -11 Intelligent FirePrintl"" Detector 1 .45 EAD -3 Weatherproof enclosure for Duct Housing 5.5 2.5 Model Description Part Number RLI.1 Remote (red) alarm indicator - 4" octagon box mount 500 - 390673 - RLI -2 Remote (red) alarm indicator - single gang box mount 500 - 390674 Note: Minimum hardware required is one Air Duct Housing Assembly, one Sampling Tube and one Detector. NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such voids all warranties either expressed or implied in regard to loss, damage, liabilities and /or service problems Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 5/03 Brampton, Ontario Siemens Building Technologies 2 5M Canada L6T 5E4 g Thli g FAX: Tel: (973) (973) 593 593 - -667 600 0 SFS -IG Tel: (905) 799 -9937 May 2003 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 -9858 s"persedesweetdatad4ro2 SIEMENS Fire Safety TRI Series Intelligent Initiating Devices Interface Modules for MXL Fire Detection Panels TRI - S,TRI - D,TRI -R ENGINEER AND ARCHITECT SPECIFICATIONS • Interfaces and Supervises Normally Open Contacts • Integral SPDT Relay (up to 4 amps) on TRI -R Model • Dual Input onTRl -D Model • Multi -color L.E.D. indicates status (green, amber, red) { • Easy front access to programming port and • wiring terminals • Mounts in 4 inch square 2 deep box, or double gang box • - • Dynamic Supervision • ,�� ���� PI'SCON • Comes with 5x5 inch faceplate owicEA REFORT�N�REA EN; :T S T S` ° 8 • Two wire operation i'ERMit4A�S l • hRC P � N 'ER • Model DPU or FPI -32 Programs and Verifies ;IMIT Eo Device's Address and Tests Device's functionality �EME • Electronic Address Programming is Easy and Dependable • 0 UL Listed, ULC Listed CFSM, FM, NYMEA Approved Introduction module reports the contact's status to the control The TRI Series Intelligent interface modules are panel. The TRI -S model can only monitor and report the designed to provide the means of interfacing direct status of the contact, while the TRI -R incorporates an shorting devices to the MXL system's ALD loop addressable Form C relay. The TRI -R relay and contact circuit. device input are controlled at the same address. For the MXL system, the relay and input contact can be The TRI Series Intelligent interface modules provide controlled as a separate function. The relay is typically the market's most advanced method of address used where control or shunting of external equipment programming and supervision, combined with sophis- is required. ticated control panel communication. Each TRI Series interface module incorporates a microcomputer chip. The TRI -D is a dual input module and is designed to The TRI Series microcomputer chip technology and its supervise and monitor two sets of dry contacts. This sophisticated bi- directional communication capabilities interface module requires two address settings. The with the control panel, achieve the state of an "Intelli- TRI -D is ideal for monitoring a waterflow switch and its gent Device" respective valve tamper switch. The TRI has a multi -color Light Emitting Diode that Description flashes green when operating normally, amber if unit The TRI Series Intelligent interface modules are avail- able in three models. The TRI -S and TRI -R are designed to monitor a normally open dry contact. The interface CATALOG NUMBER 6179 is in trouble condition, and red to indicate a change of Mounting Data state. The TRI-D flashes twice, once for each address, Addressable interface Model TRI -S, TRI -D, TRI -R the TRI R red L.E.D. indicates a change of state in mounts directly into a 4 inch square 2 deep box the relay. or a double gang box (user supplied). A 5 inch square The device's microcomputer chip has the capacity of off -white faceplate is included with each TRI. storing, in memory, identification information as well as important operating status information. MOUNTING SLOTS FOR 4 INCH Siemens Building Technologies, Fire Safety Division SWITCHBOX innovative technology allows all TRI Series intelligent interface modules to be programmed by using the ■ model DPU or FPI -32 Programmer/Tester. The Pro- 0 . 0 grammer/Tester is a compact, portable, menu driven - accessory that makes programming and testing an t TRI S/ - / - interface device faster, easier and more dependable DI rowq MODULE than previous methods. i ,,, ° The DPU or FPI -32 eliminates the need for mechanical ����� MOUNTING addressing mechanisms, such as program jumpers, ■ -�I HOLES FOR DIP switches or rotary dials, because the Programmer/ ► SWITCHPLATE A ga Tester electronically sets the TRI interface's address into the interface's microcomputer chip nonvolatile 0 memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. MOUNTING SLOTS The TRI Series is fitted with screw terminals for FOR DOUBLEGANG connection to an addressable circuit. SWITCHBOX The TRI Series is fully compatible on the same MXL Figure A circuit with all intelligent FR IL and ID -60 Series Mounting theTRl- S / -R / -D detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICP. Electrical Ratings All TRI Series intelligent interface modules are Current Draw (Active or Standby): 1.5mA UL listed. Environmental operating conditions for all TRI Series es i Relay R 1 25s R modules are 32 °F ( °C) to 120 °F (49 °C) with a relative Resistive: 4A, 1 VAC humidity of not greater than 93% non - condensating. 4A, 30 VDC Inductive: 3.5A, 120 VAC (0.6P.F.) Ordering Information 3.OA, 30 VDC (0.6P.F.) 2.0A, 120 VAC (0.4P.F.) Shipping Wt. 2.0A, 120 VAC (0.35P.F.) Model Description Lb. Kg. 2.OA, 30 VDC (0.35P.F.) TRI -S Single Input 7 oz. 2 TRI -R Single Input w/Relay 7 oz. 2 TRI -D Dual Input 7 oz. 2 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 7/03 Brampton, Ontario Siemens Building Technologies Tel: (973) 593 -2600 5M Canada L6T 5E4 9 g FAX: (973) 593 -6670 SFS-IG Tel: (905) 799 -9937 July 2003 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (9051 799 -9858 Supersedes ~dated Mona al : 7 41 I I IVIEA g, ADA ' O SYSTEMS 1 �� ' Helping People Take Actions" SERIES RSS & RSSP SINGLE & MULTI - CANDELA STROBES & STROBE PLATES F,-ME DESCRIPTION a • • Wheelock's patented Series RSS Strobe Appliances and FIRE t W r... Series RSSP Strobe Plates have lower current draw while ` <' ' maintaining outstanding performance, reliability and cost — �,.. effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount Series RSS RSS Round applications. Series RSSP Strobe options for wall mount models include 1575 or .__ , i - Wheelock's Patented MCW multi - candela strobe with field selectable candela settings of 15/30/75/110cd or the high p intensity MCWH strobe with field selectable 135/185cd. — t 3 its Ceiling mount models include the patented MCC multi �' `" �r� candela ceiling strobe with field selectable intensities of Multi -Candela Indicator 15/30/75/95cd or the high intensity MCCH strobe with (bottom of Strobe Lens) field selectable 1151177cd. Features All models may be synchronized using the Wheelock • Approvals include: UL Standard 1971, New York City SM, DSM Sync Modules or the PS- 12/24 -8CP and (MEA), California State Fire Marshal (CSFM), Factory PS- 12/24 -8MP Power Supplies with Wheelock's Patented Mutual (FM), and Chicago (BFP) See approvals by Sync Protocol. Synchronized strobes can eliminate model in Specifications and Ordering Information possible restrictions on the number of strobes in the field • ADA/NFPA/UFC /ANSI compliant. Meets OSHA 29 of view. Wheelock's synchronized strobes offer an easy Part 1910.165 way to comply with ADA recommendations concerning • Wall mount Multi- Candela models are available photosensitive epilepsy as well as meeting the with Field Selectable Candela Settings of 15/30/ requirements of NFPA72. 75/110cd or 135/185cd. Single Candela models are available in 1575cd Wheelock's Series RSS Strobes employ a Patented • Ceiling mount Multi - Candela models are Integral Strobe Mounting Plate that can be mounted to a available with field selectable candela settings of single gang, double gang, 4" square. 100mm European 15/30/75/95cd or 115/177cd. (Round or Square) backboxes or the SHBB surface backbox. If the flush • Strobes produce 1 flash per second over the backbox has side or top space between it and the finished regulated voltage range wall, the NATP (Notification Appliance Trimplate) may be • 12 and 24 VDC models with wide UL "Regulated used. It provides an additional .65" of trim for the Appliance. Voltage" using filtered (DC) or unfiltered VRMS input An attractive cover plate is provided for a clean, finished voltage appearance on all models. • Synchronize using Wheelock's sync modules or power supplies with built -in sync protocol The Series RSSP Multi- Candela Strobe Plates are a cost • Fast installation with IN /OUT screw terminals using effective way to retrofit required wall strobe appliances to #12 to #18 AWG wire bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, lnc. All rights reserved. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. 0 WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2 %). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current" RSS /RSSP RSS/RSSP - Wall Mount RSS - Ceiling Mount 24VDC 241575W 24MCW 24MCWH 24MCC 24MCCH Models 7 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max" 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS /RSSP RSS /RSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC . Wall Mount rating is the maximum RMS current within the listed voltage range (16 -33v Models 121575W for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FVVR ratings, UL max* 0.255 see installation instructions. Table 2: Audibles /Speakers for RSSP Strobe Plate Product Series Muttitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB- G6/G10 Speakers ET- 1010/1080, E70, ET70 Chimes CH70 Aj WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE ". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams # SERIES RSS/RSSP APPLIANCE SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT FROM + + TO NEXT I SM PRECEDING APPLIANCE F _ G STROBE APPLIANCE, SYNC II` OR EOLR • STROBE GP MODULE, POWER ^ ^ A SNAG 0 SUPPLY OR FACP 4 • Circuit �� � C / (� , , .Audible ll P p l -�, z EOLR t �J� Audible SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH SERIES RSS/RSSP APPLIANCES SYNCHRONIZED DSM MODULE SINGLE CLASS "A" NAC CIRCUIT WITH MULTIPLE DSM MODULES DSM DSM #1 STROBE - 0 Strode NAC 0 Sync CIRCUIT E ® N NAC SYNC Cir m . UT� F 0 4 O� • 0 T .. IN 1 I DSM #2 IN1 A EM i f .,l� j CO M +US i Strobe NAC Cir' C ■ AUDIBLE I DSM #3 PIE S t MINUS 2 Sync B®X® • ��� robe NAC Cir � t TROBE NAC DSM Interconnecting wiring shown. Maximum of CIRCUIT twenty (20) RETURN STROBE/PLATE ASSEMBLY SERIES RSS /RSSP APPLIANCES SYNCHRONIZED AUDIBLE &VISIBLEAPPLIANCE OPERATE IN UNISON WITH PS - 12124 - 8CP or PS - 12/24 - 8MP Series P5 -12E24 -8MP TO NEXT FROM + APPLIANCE OUTPUTS AS .< ® EC -A PRECEDING ± - OR EOLR F 7-4 ^u APPLIANCE, SYNC IWI A 4-CLASS O R MODULE, POWER i C 2- ASS AS < SUPPLY OR FACP 0 LA P STROBE 4115151 F AS\ _,eves PS- 1:1'24 -8MP STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLEAPPLIANCE OPERATE INDEPENDENTLY FROM + + TO NEXT PRECEDING APPLIANCE APPLIANCE OR . - OR EOLR FACP FROM + 1 - — ) r — — — — — — + TO NEXT PRECEDING STROBE OR . STROBE. SYNC — - — 1 1 r - EOLR MODULE, POWER SUPPLY OR FACE ', ; ® STROBE APPLIANCE " For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24 -8CP and P84333 for PS- 12/24 -8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified. applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL). National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including. but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing - Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS- 12124 -8CP • and PS- 12/24 -8MP Power Supplies with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi - Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE. Due to continuous development of our products. specifications and offerings are subject to change without notice in accordance with Wheelock. Inc standard terms and conditions. Specifications and Ordering Information Order ' Wall Ceiling I Non- Sync WI SM,DSM Strobe 24 12 6 Model R Modal Square or ' Apenu y Approvals Model or ' Color Color Mounting Options• - ' Code Mount Mount Sync PS- 12/24 Candela VDC VDC RED WHITE Round I UL MEA CSFM FM, BFP RSS- 24MCW -FR 9400 X - X X 1530/75/110 X: - , X - B,D,E,F,QH,J,N,O,RX Square X X X X X RSS- 24MCW -FW 9401 X - X X 15/30/751110 X � X B,D,E,FQH,JN,O,RX Square X X X X X RSS- 241575W -FR 7471 X - X X 15 (75 on Aida) 1 X 1 - I X - B,D,E,F,QH,J,N,O,RX Square X X X X X RSS- 241575•FW 1 7798 X - X X 15 (75 on Axis) I X' - X B,D,E,F,QH,J,N,O,R,X Square X • X X X X RSS- 121575W -FR ' 7476 X - ' X - x 15 (75 on Ada) - ' X I X - B,D,E,F,QH,J,N,O,RX Square X X X X X RSS- 121575W-FW 7468 X - I X X 15 (75 on Ada) • X i - X B,D,E,F,QH,J,N,O,R,X Square X' X X X X RSS- 24MCC -FW 3166 - X X X 15/30175196 X -' - X B,D,E,F,QH,J,N,O-RX Square X X X X • t- RSS- 24MCC-FR : 3167 - X X X 15/30175/95 X i - X - B D E F,QH,J,N,O,R.X Square I X - X X X • RSS- 241ACCR -FW 1 3160 - X L X X 15130/7515 X - ' X B,D,E,F,QH,J,N,O,RX Round I X; X X X • RSS- 24MCCR -FR i 3159 - X I X X 15/30775195 • X I • - X ' . - B,D,E,F,QHd,N,O,RX Rom! X �X X X • 1955- 24MCCHfiW 3461 • X I X X 1157177 X - - I X • B,D,E,F,QH,J,N,O,RX Square I X X X • • .. --- - 1 - ... __ —_.__ . —._... RSS- 24MCCI-19 -FW 3463 - X X X 116/177 X - - X B,D,E,F,QH,J,N,O,RX Round X X X • • RSS- 24MCWHFFR 34661 X ! _ ....._. . X .. _ X 135/185 X X I B,D,E,F,QH.J,N.O,R,X • Square X X X • • } - .. ._ __._.. .. ....__.. _. RSSWR- 2475W-FR" 9013 I X , - X X 75 •31'F 1800 .3,7 1. X; - X - B,D,E,F,GH,J,N,O,RX Square X X X X • • RSSWP- 2475W -F• . 3034. X' - X X 75 ® � X - ( X BA,E,F,QH,J,N,O,R,X Square X X X X • RSSP-121575W-FR 7798 _ X - X X 15 (75 on Aab) _ ; X i X ( - D,E2 Square X X X X X RSSP- 24MCW -FR 9402 X , - X X 15/307757110 X 1 - X I - D,EZ Square I X X X X X RSSP- 241575W -FR 7793 X w W - - X X 15 (75 on Aoa)' - i X - D,EZ __ Square X X X X X RSSP- 24MCWH -FR 9482 X X X 1357185 ` X X B D E,F,QH,J,N,O,RX Square X X X • • - 1__ �. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. *PENDING * *For Weatherproof Series RSS Strobe specifications see data sheet S9004. "'Refer to data sheet S7000 for mounting options. - WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE Distributed By: 1 631 - 2148 igintil Canada 800 397 -5777 E -mail :Info @wheelockinc.com Member ,. http: / /www.wheelockinc.com WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732 - 222 -6880 • FAX: 732 - 222 -2588 SO410 05/05 whe_elock UL ADA s e. Helping People Take Actions' SERIES E50 SPEAKERS & SPEAKER STROBES Description Wheelock's Series E50 Speakers and Speaker Strobes feature high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. They are designed to provide a sleek, aesthetic appearance for emergency voice /alarm communications systems. All Series ;iii: E50 models mount to standard 4" x 2 -1/8" electrical boxes (with no extension ring required) and incorporate a speaker E SERIES E50 mounting plate for faster installation. The grille cover snaps on so no mounting screws are visible. Attractive surface boxes — -- ' Speaker are also available for surface installations. SERIES E50 Speaker Strobe The Series E50 Speaker Strobe models use Wheelock's low current draw Series RSS strobes for wall mounted applications. Strobe options include patented MCW multi - candela strobes with field selectable candela settings of 15/30/75/110 cd or Features high intensity MCWH strobes with field selectable 135/185 candela. Models with 1575 candela (75 cd on axis) are also • Approvals include: UL Standard 1971, UL Standard offered. 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago Series E50 Speakers and Speaker Strobes provide high audio (BFP). See approvals by model in Specifications output with clear audibility and are designed to meet the critical and Ordering Information needs of the life safety industry for effective emergency voice • ADA/NFPA/ANSI compliant communications, tone signaling and visible signaling to alert • Complies with OSHA 29 Part 1910.165 the hearing impaired. • Wall mount speaker strobe models with field selectable candela settings of 15/30/75/110cd or 135/ The strobe portion of all Series E Speaker Strobes may be 185cd (Multi - Candela models), or 1575cd (Single synchronized when used in conjunction with the Wheelock Candela model) SM, DSM Sync Modules or Wheelock's PS- 12/24 -8CP and • Field selectable taps for 25 or 70 VRMS operation PS- 12/24 -8MP Power Supplies with Patented Sync Protocol. from 1/8 watt up to 2 watts Wheelock's synchronized strobes offer an easy way to comply • High efficiency design for maximum output at with ADA and NFPA regulations concerning photosensitive minimum wattage across a frequency range of 400 epilepsy. to 4000 HZ • 24 VDC strobes produce 1 flash per second with Series E50 Speaker Strobes are UL Listed for indoor use under wide UL "Regulated Voltage" of 16 to 33 volts using Standard 1971 (Signaling Devices for the Hearing- Impaired) filtered DC or unfiltered VRMS input voltage and Standard 1480 (Speaker Appliances). All inputs employ • Synchronize with Wheelock SM, DSM or Wheelock IN /OUT wiring terminals for fast installation using #12 to #18 PS- 12/24 -8CP and PS- 12/24 -8MP Power Supply AWG wiring and are compatible with FACP line supervision. with built -in sync protocol • Mount to 4" square x 2 -1/8" deep backbox with no Color options for the Series E50 Speakers and Speaker Strobes extension ring required are red or off - white. • Snap on grille cover with no visible mounting screws • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wires Copyright 2004 Wheelock Inc. All rights reserved. NOTE: All CAUTIONS and WARNINGS are identified by the symbol& . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series E50 Speaker Strobes and Series E50 Speakers are listed for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 85 %. Table 1: Average RMS Current E50 Strobe Current - Wall Mount * RMS current ratings are per UL average RMS E50 method. UL max current rating is the maximum Speaker 241575W 24MCW 24MCWH RMS current within the listed voltage range (16 -33v Strobes for 24v units). For strobes the UL max current is 1575cd 15cd 30cd 75cd 110cd 135cd 185cd usually at the minimum listed voltage (16v for 24v 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 units). For unfiltered FWR ratings, see installation instructions. UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 Table 2: E50 UL Reverberant dBA@ 10 Feet** watts 1/8 1/4 1/2 1 2 E50 Speaker 77 79.5 82.5 85 88 E50 Speaker Strobe 77 79.5 82.5 85 88 * *dBA ratings are based on UL testing under UL Standard 1480 L► WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALLAPPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. - FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELASETTINGS WILLAFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCES OR FUSES. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE ". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams# SERIES E50 SPEAKER & STROBE OPERATE SERIES E50 SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY (NON-SYNC OR SYNC) WITH MULTIPLE DSM MODULES DSM #1 FROM TIT TO PRECEDING + NE x N CC APPLIANCE S trobe NAC CN. Sy 'M APPLIANCE E r!A 50 5o OR VOCE °° E ° � F F gy m - Note: Figure shows EPµACUATIOEL A N I DSM #2 interconnection to Strooe NAC Cr161111 N strobe through sync PRECEDING STROBE C, ■ STROBE – - — t"1 r — — — — — - EOLP C module. Speaker SYNC MODULE. I DSM #3 PONER SUPPLY portion requires 2 °° `ALP Strobe NAC CN ` mar separate conductors to communications STROBE SPEAKER DSM Interconnecting wiring shown. Malamum of system. twenty (20) SERIES E50 SPEAKER STROBE APPLIANCES SERIES E50 SPEAKER STROBE APPLIANCES & RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH PS- 12/24 -8CP and CLASS "A" PS- 12/24 -8MP DSM Senes PS- 1224 -8MP or PS- 1224 -8CP STROBE NAC SYNC T 0 CIRCUIT • OUT /' t _ OUTPUTS ®' EOLR + IN 1 MINCIrso r :1: • , FACP /i \ AUDIBLE o MINUS 2 P . IN 2 1:11' C.'C1'; STROBE Our 2 JL _ , \ �•, NAC Series PS 1224 - 8MP CIRCUIT RETURN or PS -1224 -8CP For wiring information on the PS- 12/24 -8CP and PS- 12/24 -8MP Power Supply, please refer to Data Sheet #9000. # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24 -8CP and P84333 for PS -12/24 -8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed. operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS AND ENGINEERS SPECIFICATIONS The speaker appliances shall be Wheelock Series E50 Speakers and the speaker strobe appliances shall be Wheelock Series E50 Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing- Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 89 dBA at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second • over the Regulated Voltage Range and shall be of low current design. Where Multi - Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mounting. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required. When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock's SM, DSM sync modules or Wheelock's PS- 12/24 -8CP and PS- 12/24 -8MP Power Supplies with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting to 4" x 2 -1/8" electrical boxes without need for an extension ring or surface mounting to Wheelock's E5OSB or E5OSSB surface boxes. The speaker and speaker strobe shall incorporate a speaker mounting plate with a snap -on grille cover. The finish of the Series E50 speakers and speakers strobes shall be white or red. SPECIFICATIONS AND ORDERING INFORMATION Order Wall Ceiling Strobe Grill Flush Mount Surface Mounting Agency Approvals Model Code Mount Mount Candela Color Backbox Backbox Options UL MEA CSFM FM BFP E50 -R 0222 X X - Red 4' x4" x 2 -1/8" E5OSB -R E,O,P,Q,R,U,Y,AA X * * X * E50-W 0223 X X - White 4'x4 "x2 -1/8" E5OSB-W E,O,P,Q,R,U,Y,AA X * * X * E50- 241575W -FR 0224 X - 15 (75 on Axis) Red 4' x 4" x 2 -1/8" E5OSSB -R E,Q,U,BB X * * X * E50- 241575W -FW 0225 X - 15 (75 on Axis) White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB X * * X * E50- 24MCU -FR 0226 X - 15/30/75/110 Red 4' x 4" x 2 -1/6" • E5OSSB-R E,Q,U,BB X * * X * E50- 24MCW -FW 0227 X - 15/30/75/110 White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB X * * X * E50- 24MCWH -FR 0228 X - 135/185 Red 4' x 4" x 2 -1/8" E5OSSB -R E,Q,U,BB X * * X * E50- 24MCWH -FW 0229 X - 135/185 White 4' x 4" x 2 -1/8" I E50 -SSB -W E,Q,U,BB X * * X * * PENDING NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Distributed By: National Sales Office Made in USA 800 - 631 -2148 Canada 800 - 397 -5777 E -Mail: Info @wheelockinc.com sa.anws•I11 http: / /www.wheelockinc.com 273 Branchport Avenue • Long Branch, NJ 07740 • TEL: 732 -222 -6880 • FAX: 732 - 222 -2588 S0510 02/05 FIRE SYSTEM FUNCTION MATRIX SIEMENS Washington Square Revision: 0 Teavana 261007 SYSTEM RESPONSE a) 0 N a) a) a o U) P. a) U co f0 ✓ a) T) a c f- T c E to c c f9 N m a- 45 a E Q m m c a) D it Q LL U) m Q a) T O) c LL J 'O - C a) al LL z., V 7 Ca @ N i5 zs 7 rn m I 0 N W o 7 N O J Q o w p L ', ) v) O V) O a s ` a 0 o a 2 m 2 o ` te a E a�i E a a a) INITIATION DEVICE ACTIVATED Q u ) Q H u ) Q H , co Area Smoke /Heat Detector X X X Air Handler Duct Smoke Detector X X X X Waterflow Switch X X X Valve Tamper Switch X X Fire System Trouble X X PROPRIETARY DOCUMENT FOR APPROVAL ONLY 4 10/28/2005 BATTERY SIZING CALCULATIONS SI EM ENS Washington Square Teavana Panel Name: FAPS -1 Battery Size: 7 amp -hr 24 hrs. Design Supervison Current = 2.00 amp -hr Requirement for alarm current. 15 min. Design Alarm Current = 1.00 amp -hr Spare Battery Capacity: 25 % Additional Capacity Current = 0.75 amp -hr Initiating Devices Assumed In Alarm: 10 % Battery AH requirement = 3.75 amp -hr PANEL EQUIPMENT Standby Alarm TOTAL TOTAL (ma) (ma) (ma) (ma) Quantity Device Current Current Standby Current Alarm Current Model PS- 12/24 -8MP 60 150 60 150 PANEL TOTALS 60 150 6 15cd STROBE 50 300 30cd STROBE 8 • 0 75cd STROBE 133 0 110cd STROBE 161 0 10 15cd SPKR /STROBE 47 470 5 30cd SPKR /STROBE 81 • 405 6 75cd SPKR /STROBE 130 780 11 110cd SPKR /STROBE 171 1881 0 FIELD TOTALS 0 3836 ..... • Standby Alarm GRAND TOTALS (field & panel) 60 I 3986 I Formula: [(A + B) x C] + [(D + E) x F] x G = Minimum Amp -Hour Battery Capacity Where: A = Internal panel standby current {amps }. B = External device standby current {amps }. C = Duration panel must remain operational {hours }. E = External device alarm current {amps }. F = Duration panel must remain in alarm after standby period ends {hours }. G = Spare battery capacity {percentage }. PROPRIETARY DOCUMENT FOR APPROVAL ONLY 10/28/2005 IAC CIRCUIT CALCULATIONS SIEMENS Washington Square Teavana 261007 W W a J m 0 p, 0 a, a, v m a q w o o y 0 0 0 O Q ) p p o O a '' c d 6 :- s d a w -0 v N 0 t ry C l) l y o °' O -s O O ¢ °' a 5 O a, c a H a, ;( o 2 a O . ` .`>C a x . a d O a O -J 0 a t U _ y V. J C U a N (% cn v N N q to N N y t 0 % m (1 o an 'El. a > J J U y 3 a a 4 « a Zu h a v; o u y a r n a d a d N p u o a 0 m d L. dp o p o a ' N ov v ° v1 nh o d h ° :: h O n o o 0 , O o 0 0 U. .a k 0 F F a R _r=te :-C w W M H r.vi W p c, ti ¢ O O i-- 1-... Q., LxR Rx2 15 3( 75 110 15 30 75 110 DH #xl IxR 24 -VD FAPS -1 N1 -1 415 14 0.0026 1.08 2.16 2 0 0 0 6 0 0 5 1.45 3.12 20.88 13.0% 48.2% N1 -2 450 14 0.0026 1.17 2.34 0 0 0 0 0 r 4 0.73 1.71 22.29 7.1% 24.4% N1 -3 490 14 0.0026 1.27 2.55 3 0 0 0 3 0 4 2 1.34 3.42 20.58 14.3% 44.8% N1-4 465 14 0 0026 1 21 2.42 _ 3 0 0 _ 3 3 3 1 0 1.29 3.12 20.88 13.0% 43.0% 60.2% 4.81 AMPS 8 12 3 7 12 Enter Pow 6 8.0 AMPS Capacity Per Output 1 3.0 AMPS' Enter Strobe Wire Size 14 Gua•e 15cd Strobe RSS Series .050 RSS - 24MCW - FW Multi - Candela Strobes 30cd Strobe RSS Series .081 75cd Strobe RSS Series .133 110cd Strobe RSS Series .161 @ 15cd Spkr /Strobe E50 Series .072 20.4 E50- 24MCW -FW Multi - Candela Speaker /Strobe 30cd Spkr /Strobe E50 Series .094 , VDC 75cd Spkr /Strobe E50 Series .153 110cd Spkr /Strobe E50 Series .183 DOORHOLDER .096 150X OR EQUIVELANT (Supplied by Others) 24VDC RISER (AMPS) .000 Enter 24VDC Riser Wire Size 14 Guage PROPRIETARY DOCUMENT FOR APPROVAL ONLY 10/28/2006