Correspondence September 21, 2005 CITY OF TIGARD Jeffery Strockbine OREGON Olympic Associates Company 701 Dexter Avenue North, Suite # 301 Seattle, WA 98109 Project Information Building Permit: MEC2005 -00555 Occupancy Type: B Tenant Name: Washignton Square Starbucks Construction Type: IIB Address: 9359 SW Washington Square Road Occupant Load: 43 Area: 1,572 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2004 edition; and the State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are approved subject to the following. 1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 2. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 3. Appliances serving different areas of a building other than where they are installed shall be permanently marked in an approved manner that uniquely identifies the appliance and the area it serves. 304.11 OMSC 4. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 5. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 6. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.2 OMSC 7. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 8. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall be provided with a permanent means of access grade or floor level. 306.5 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and process'il, 1e documents. R te" :'. :alp Senior Examiner 09- 21 -'05 10:53 FROM- T -101 P002/002 F -169 3 /" HILTI HDI DROP -IN ANCHOR IN CONCRETE FLOOR DECK TYPICAL EACH THREADED ROD III SPRING ISOLATOR,EACH THREADED ROD INSTALL 10 PER MFG. SPECIFICATIONS 3 / 8 " THREADED ROD HANGER (4) PLACES BOLT TO AHU PER MFG. SPECIFICATIONS d 45 12 G:Wu IRE OF AS 45 SHOWN DEGREES 8 _ PLAS TO BE ATTACHED AT M MIN. 45° MAX OF (4) TIGHT TURNS IN 1Y2" 45 ' � 5 AT BOTH ENDS OF ALL BRACING ° WIRE 45° AHU SEE MECHANICAL FOR DIMENSIONS 45° . 45° its 1 AIR HANDLER UNIT SUPPORT 1 /2a = 1 , A a - (, r - - DATE: 9/21/2005 PAGE; 1 OF 1 r r , DRAWN: C. TERAO SHEET SUPPL E MENTAL DETAILS • CHECKED: REFFRENCED . r17 STARBUCKS WASHINGTON SQUARE III oL►�P(S REVISION • _ - A150(IATU JOB NO. 2005086 NUMBER: c o 4 r A i r ,a Arieaoacermaq 4cm mount ar Doha mm°o owner „° Nc wor TO a •m « mom a. M ow incur mo m Wo:oB,mI o/ wins ,SIDZOCI �6YXI •