Correspondence October 4, 2005 he't°Dlioll I C I I\ CITY OF TIGARD OREGON Oregon Electric Group Loni Martin 1010 SE 11 Portland, OR 97214 RE: MODIFICATION- FIRE ALARM SYSTEM Project Information Building Permit: BUP2005 -00486 Construction Type: 11 -B Tenant Name: Chico Occupancy Type: M Address: 9318 SW Washington Sq Occupant Load: NA Area: 4,701 sq ft Stories: 1 Hazard: Ordinary Group Sprinklers: YES The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Oregon Fire Code 2004 edition. The following information is required in order to complete the review. 1. Provide system design showing alarm designated to the address noted above using J box Q - as required per NFPA 4.2. "The purpose offire alarm systems shall be primarily to provide notification offire alarm, supervisory, and trouble conditions; to alert the occupants; to summon aid; and to control fire safety functions." When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henzel, Senior Plans Examiner • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • October 10, 2005 II • CITY OF TIGARD OREGON Oregon Electric Group Loni Martin 1010 SE 11 Portland, OR 97214 RE: FIRE ALARM SYSTEM Project Information Building Permit: BUP2005 -00486 Construction Type: II-B Tenant Name: Chico Occupancy Type: M Address: • 9318 SW Washington Sq Occupant Load: NA Area: 4,701 sq ft Stories: 1 Hazard: Ordinary Group Sprinklers: YES The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Oregon Fire Code 2004 edition. The submitted plans are approved subject to the following. General requirements 1. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the Fire Chief All functions of the system or alteration shall be tested. 901.5 OSSC 2. The permittee shall provide written certification to the Fire Chief that the system has been installed in accordance with the approved plans and specifications. A copy of the completed form shall be maintained on the premises and made available to the Fire Chief. 901.2.1 OFC 3. Connections to the light and power service shall be on a dedicated branch circuit. The circuit and connections shall be mechanically protected. The circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly and permanently marked FIRE ALARM CIRCUIT CONTROL. 907.5 OFC Visuals (Section 1109.14 OSSC) 4. Visual signal appliances shall be provided in the building in each of the following areas: • Restrooms and any other general use area (e.g., meeting rooms) • Hallways /Corridors 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 s' • Lobbies • Common use areas. 5. Visual alarms shall be located not less than 80 inches and not more than 96 inches above the floor level. When a low ceiling exists, the visual alarm shall be mounted at least 6 inches below the ceiling. 6. No place in a room shall be more than 50 feet from a visual signal. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectful , Val He , Senior Plans Examiner • •