Loading...
Specifications (ju.i\ RECEIVED FEB 11 2004 CITY OF TIGARD ShawWesRS BUILDING DIVISION ELECTRICAL CONTRACTORS Fowler Middle School Job # 0337 FIRE ALARM UPGRADE SUBMITTALS PROJECT ADDRESS Fowler Middle School 10865 SW Walnut Tigard, OR 97223 OWNER Tigard - Tualatin School District 6960 SW Sandburg St. Tigard, OR 97223 OWNER'S REPRESENTATIVE Cornerstone Construction Mgmt. 5410 SW Macadam Ave., Suite 250 Portland, OR 97201 ARCHITECT Dull Olson Weekes Architects 319 SW Washington St., Suite 200 Portland, OR 97204 ENGINEER MFIA Inc. 2007 SE Ash Street Portland, OR 97214 ELECTRICAL CONTRACTOR Shaw West Co. • P.O. Box 1427 Tualatin, OR 97062 City of Tigard Approved Plans By 0 Date 2 7 04 ' Due 2-004 - 000 T July 6, 2001 • DN -5262 • A -103 } "= �-� �' �® AFP -300 and AFP -400 Analog Fire Panels Section: Intelligent Fire Alarm Control Panels GENERAL The AFP -300 and AFP -400 are compact, cost - effective, in State a,E. telligent fire alarm control panels with a total capacity of up UC Ili) „ ... Marshal to 563 points and an extensive list of powerful features. The I. ' -i 7170- 0028:182 AFP- 300/400 integrates conventional output circuits, such 05118/733 7165- 0028:181 as notification, telephone, - and speakers, with the intelligent LISTED features of one or two signaling line circuits (SLC) and 198 S635 City of 41t; or 396 intelligent/addressable points. FEATURES M EA Chicago loop (AFP-300) loops (AFP -400 Style 4, 6 or 7. 17-96 -E (AFP -400) A CLASS 1: 1291 E • One loo AFP -300 or two loo , . CLASS 2: 1729E • 198 intelligent devices per loop (99 intelligent detectors 17-96-E Vol. II (AFP -300) and 99 intelligent modules). s , .. • 396 Intelligent device capacity on the AFP -400; 198 on the AFP -300. I — — • VIEW®, HARSHTM, Advanced Multi- Sensor (AMS) op ! , I ®►nth ( tons - 1.7.] ,: : ,t • Up to 68 internal circuits /relays, plus 99 programmable h t a' L1 -;®>w t * -- i'w i zone output relays for a total capacity of 563 points. • Four integral Notification Appliance (signal) Circuits , (NACs), Style Z or Y (Class A or B). • 6.0 A power supply, plus 6.0 A expanders. N ( 3 • NACs may be programmed for Steady, March Time Tem f poral, California code, or Canadian Two - Stage. , _~-- f • Modified California code, pulsed on time. • Tornado Warning activates different Notification Appli P ance Circuit code. • Alarm, Trouble, Supervisory, and Security relays, stan- z dard. �or�FtA 's • Peer -to -peer network- ready. -T r q E • Intelligent features: ✓ Manual sensitivity adjustment - 9 levels. • Sensitivity windows: ✓ Pre -alarm AWACSTM - 9 levels. ✓ ION - 0.5 to 2.5 %/foot obscuration. ✓ Day /Night automatic sensitivity adjustment. ✓ PHOTO - 0.5 to 2.35 % /foot obscuration. ✓ Drift compensation (U.S. Patent Pending). ✓ MULTI- SENSOR - 0.71 to 4.0% /foot obscuration. ✓ Multi - detector algorithm involves nearby detectors in ✓ VIEW® - 0.03 to 1.0% /foot obscuration. alarm decision (patent pending). Low- pressure CO support: ✓ Auto detector test (meets NFPA 72). ✓ Expanded soak timer - 0 to 9999 seconds. ✓ Maintenance alert (two levels). ✓ Manual release delay (10 seconds) type ID. ✓ Self - optimizing pre -alarm adjusts pre -alarm level to ✓ "Second shot” monitor module type iD. environment automatically. ✓ Triple -coded notification circuit type ID. ✓ Activate local sounder base on pre- alarm. • Voice and telephone features: ✓ LED blink control for sleeping areas. ✓ Solid state message generation. ✓ Automatic device type check. ✓ Hard -wired voice control module options (System 5000 ✓ Trouble after 20 detector verifications. class modules). • Releasing features: ✓ Distributed voice options (XP transponders). ✓ Ten independent hazards. ✓ Firefighter telephone option. ✓ Sophisticated cross -zone (three options). ✓ 30- to 120 -watt high - efficiency amplifier. ✓ Delay timer and Discharge timers (adjustable). ✓ Backup tone generator and amplifier option. ✓ Abort (four options). ✓ Dual channel option. • Telephone control module type ID. This document is not intended be used for installation purposes. We try keep our '�® ® ®� product information up -to -date and accurate We cannot cover at specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone* (203) 484 -7161 FAX: (203) 484 -7118 c ER - 1 1F , EEO. �yr N OTI Fl Elam 12 Clintonville Road, Northford, Connecticut 06472 MINOR & NIANOFACIIIRIN6 Made in the U.S.A DN- 5262.07/06/01 — Page 1 of 10 1 T FEATURES, continued • Optional UDACT, 396- channeb digital alarm communi -, cator transmitter with AC fail delay. ' • 80- character displays (up to 32) for remote annuncia- tion. ACS annunciators (EIA -485), including LDM custom. -- • Two -wire detector interface provides compatibility with many manufacturers' detectors,for retrofitapplications. • Integral printer interface (80- column and 40- column print- ers). •_ • • Integral' 80- character LCD display, backlit (2 lines x 40 - characters). • Field- programmable on panel or on PC, with program check, compare, simulate. • Full QWERTY keypad behind flip -down door. • Autoprogramming and Walk Test. • Identifies two devices set to the same address. • History` file with 800 -event capacity in nonvolatile memory; "plus separate'200 -event alarm -only file. • • Programmable waterfiow or supervisory selection per point... • Programmable combo zone — allows "tamper and waterflo`w `detectors 'to connect to: a common monitor module.';• °, • Alarm Verification selection' per point, with tally. • Verification Trouble counter. Trouble indication after a detector verifies 20 times: • Programmable Positive•Alarm Sequence (PAS) Presignal per NFPA 72. • Silence inhibit and Auto Silence timer options. • Programmable non -alarm points for lower priority func- tions. , • Remote ACK/Silence /Reset/brill via addressable mod- ules. • Maintenance Reports may be sorted via PC by compen- sation value (dirty detector), peak alarm value, or ad- dress. • Automatic time control ' functions, with holiday excep- tions. • Dual rate charger for up to 90 hours of standby power. • Rapid poll algorithm for manual stations. Responds to alarm /activation in less than three seconds. • SLC loop maximum length 10,000 feet (3,048 m) @ 12 AWG (3.25 mm • Surface Mount Technology (SMT) electronics. • High -speed RISC 16 -bit microprocessor. • Extensive built -in transient protection. Page 2 of 10 — DN-5262 • 07/06/01 SAMPLE SYSTEM BLOCK DIAGRAM • SLC Intelligent Loop 1 FIRE ''' 'inn" 1 FSI -751 FSP 751 DEVICES g L i " ' � Ion Photo FST -151 • • _ Thermal - NBG -12LX FMM -1 FCM -1 °� °° Fixed I 4' XP Transponder g I� I up I ®I I� I I I IDC NAC SLC Intelligent Loop 2 P. g • 32 0 E F R ' f� rte■[! LCD-80 Remote ■�. . I ; . ' Display/Control = DEVICES g ` 0 ° FSP -751T IPX•751 c..... °® Photo) FST -751R Advanced Thermal NBG 12Uf FMM-1 FCM-1 RS 485 Thermal ROR Multi- Sensor 1 XP Transponder • IDC NAC - d — ��� ��.� ��, _ RS- 485 640 annunciator /control points ddddbzShcea ■ :MOM .'2M 4 88888 - _ i - , ■ - 45• TIN ,F■s■ 1 s• w E -; Up to 68 fully • - " - I programmable u ■■ ■■ m m ( m m 4 ® --I> output circuits I L. . i I L_tr , �J I� LJ� ° L ° ° J o ®!: ®® . . .4----- : ®■ ® � ®:. 4 --- t! ®—ie IlE oJ.. ra h eta L' F L' r.g 1 r 4 = ®— � ®, 4— ® III —0* MI ■w r u um. im ■ 1 =G I. r- ®. ®® a—® . —_10. WA URN MIL/ ■: MLA : `l : ,,,.. C' .-: MIA III r LIMN 1 U RNLI I = ° 4 {: `rl - 7 r• Fill ❑M fill ❑0 Mb' ° Q-A, ::: 40,41,, ACM -8R 7 is fin; Relay Control ACMIAEM -16AT LED Annunciator LDM -32 Custom Graphics r,. x ,> 4 ., s�'tr, - i Optional 396 channel UDACT Universal p = •._ - Digital Alarm Communicator Transmitter o z ,_ _ -4 -n , °s • Dual phone lines en ► to Central Station ° -�' 4''• -.- - sa': RS - 232 Terminal ° AFP -400 1111 111 a shown In CAB -C3 RS - with voice alarm system „®,Fp., m PRN Pnnter r ---, a w CRT -2 Terminal 0 0 The CPU- 300/400 EIA -232 EIA -485 Port SLC Loop #1 EIA -232 Terminal Port "Terminal Mode" (Style 4, 6, or 7) EIA-485 Port SLC Loop #2 (AFP -400 only) Printer Port 4 (Style 4,6, or 7) /i66 fi66 q —Z 00 oev.iree cip0zoo III ■ IMI -7 ■■ no 80- Character (2 x 40) Back -Lit LCD Display Slide -in Label • : :: 4--J r ❑ ❑ ❑ ❑ ❑ ❑ ❑ ( Im 0 - �1 Ip vj 1 :"1 f j ( 1 `° ® I� r . ( Status LED's T. °°.°4 , I[ e g J 1 ., Control Switches 0 .5,)E 1 7i ; .D.( I I' i EPROM � I °. ,w I ® o - ® I `I I 'I L ' s MI ® ®. o ® ( ® I ®I1 1I - - , _ - Pro g rammin g 5 ZOOM e l ' - MOM I'M ^;.I ffI i Keypad - ' ;■--- Flip -Down Door i (covers the programming keypad) The MPS-400 M ain Power Supply Form -C Alarm, Trouble, Supervisory, and Security contacts. (3 amps @ 30 Resettable VDC) (Note: Supervisory and Security 2 non- resettable contacts can be converted to alarm 24 VDC circuits 24 VDC @ contacts.) • rated 1.25 amps 1.25 amps' NAC or Releasing , each" \� /��1 �> circuits 1 & 2. 77-7-.7:"--7:- —� Z Class A or Class B, ® i%' — - =. ec d - t e ,' '.1 24 VDC @ 2.5 eD o ® � zczte cxm� amps each.' AC Power 120/240 VAC ,® — (Field Selectable) ----- , ,..•.•.rte( ° ,-,° ^. ° � ...p �, . ., i'� ; i i �, , , ; • y oG , NAC or Releasing I J Circuits 3 & 4. L I r, 2 ^ ; Class A or B, 24 Battery (12 -60 A.H.) b2---_____,0 , VDC @ 2.5 amps • _ 2•� \ each.' ® ® �`'`., � �a Status/Trouble U LEDs o : ) ' ` , " 1 \ Optional `i ' { �7 The MPS -400 is a 6 amp Transmitter module • rliE power supply. Total power, (4XTM connector).,f including internal modules, III cannot exceed 6 amps. a UZC Coder Input __ Door Tamper Switch (STS -200) Meter Module Option (MPM -2) Page 4 of 10 — DN-5262 • 07/06/01 MPS -400: Power Supply module. The MPS -400 includes CONTROLS AND INDICATORS 4 Notification Appliance Circuits (NAC) that can Program Keypad: QWERTY type (keyboard layout). connect four Class A (Style Z) or Class 8 (Style Y) circuits. The NAC also can be used for Releasing 8 LED indicators: AC Power, Fire Alarm; Pre - Alarm; Se- applications. includes four built -in system relays curity Alarm; Supervisory Signal; System Trouble, Disabled (alarm, trouble, security, and supervisory). For BE -400 points, Alarm Silenced. replacement only. The MPS -400 is included in the BE Membrane Switch Controls: Acknowledge /Step; Silence; kits. Evacuate; System Reset; Lamp Test. MPS 400RB: MPS - 400 PC board only. Less trans LCD Display:. 80 characters (2 x 40) with long -life LED formers and mounting chassis. backlight. AGENCY LISTINGS AND APPROVALS COMPATIBLE DEVICES, EIA -232 Port See the first page of this catalog sheet for listing agencies PRN -5 80- column printer. and file numbers. These listings and approvals apply to VS4095/S2 Printer, 40 column, 24 V. Mounted in exter- the basic AFP -300 or AFP -400 control panel. In some nal backbox (order from Keltron, Inc.). cases, certain modules may not be listed by certain ap- proval agencies, or listing may be in process. Consult CRT -2 Video display terminal. factory for latest listing status. NAM -232W Wire peer -to -peer NOTI • FIRE • NET"' net - The AFP - 300/400 is UL Listed, per Standards 864 (Fire) and work interface module (see separate data 1076 (Burglary). It meets NFPA 72 Local, Auxiliary, Remote sheet). Station, Proprietary, and Emergency Voice /Alarm Fire Sys- NAM -232F Fiber peer -to -peer NOTI • FIRE • NET net - tern Requirements. work interface module (see separate data sheet). SPECIFICATIONS •VGAS Video Graphic Annunciator System • Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. (see separate data sheet). • Total output 24 V power — 6.0 A.* Note: * Not UL 864 listed (ancillary device only). • Standard Bell circuits (4) per MPS -400 — 2.5 A each. COMPATIBLE INTELLIGENT DEVICES • Four -wire detector power — 1.25 A. • Two non -reset regulated power outputs — 1.25 A each. FSI -751 Ion detector. • Battery charger range: 12 AH - 60 AH. FSP -751 Photo detector. (Use separate BB -55 cabinet for 55/60 AN batteries.) FSP -751T Photo detector with fixed thermal element. • Charge high rate: 29.1 V. Float Rate: 27.6 V. FST -751 Thermal detector, fixed. • Note: The MPS -400 has a total of 6.0 Amps of available power. FST -751 R Thermal detector, fixed and rate -of -rise. This is shared by all internal modules and each MPS -400 circuit. LPX - 751 VIEW® detector. HPX -751 HARSH"' photo detector (requires special SYSTEM CAPACITY: AFP -400 base). • Intelligent Signaling Line Circuits 2 IPX-751 Advanced multi- criteria detector (ion /photo/ • Intelligent Detectors 198 thermal). • Addressable monitor /control modules 198 FSD -751 P Duct detector, with housing. • Programmable internal hardware FSD -751RP Duct detector, with housing and relay. and output circuits (four standard) 68 INTELLIGENT DETECTOR BASES • Programmable software zones 99 B710LPBP Standard flanged base, package of ten. • Special Programming zones 14 B510BP Standard flangeless base, package of ten. • Programmable remote relay /annunciator points 99 B710HD Base for HPX -751 (HARSHTM) only. • LCD -80 annunciators per system (observe power) 32 B224RB Relay base. • ACS annunciators per system...10 Address x 64 points B224BI Isolator base. SYSTEM CAPACITY: AFP -300 B501BH Sounder base. • Intelligent Signaling Line Circuits 1 B501BHT Sounder base with temporal sounder. • Intelligent Detectors 99 COMPATIBLE ADDRESSABLE DEVICES • Addressable monitor /control modules 99 NBG -12LX Addressable pull station, visible LED. • Programmable internal hardware FMM -1 Monitor module. and output circuits (four standard) 68 FMM -101 Monitor module, miniature. • Programmable software zones 99 FDM -1 Monitor module, dual, two independent Class • Special Programming zones 14 B circuits. • Programmable remote relay /annunciator points 99 FZM -1 Monitor module, two -wire smoke detectors. • LCD -80 annunciators per system (observe power) 32 FCM -1 Control module. • ACS annunciators per system...10 Address x 64 points FRM -1 Relay module. DN-5262 • 07/06/01 — Page 9 of 10 XP5-M Transponder, monitor, five addressable Class B circuits. XP5-C Transponder, control /relay, five addressable Class B circuits. ISO -X Isolator module. NOTE: All addressable devices listed above - may only be used with the AFP- 300/400 software revision 3.61 or higher. COMPATIBLE DEVICES,'RS -485 Port (see separate data sheets) ACS Series " ..Remote,Serial Annunciator /Control sys- tems. LCD -80 Remote LCD display. LDM Series . Remote custom graphic driver modules. ACM -8R Remote relay module. 8 Form -C relays. NIB -96 Network Interface Board. RPT -485 Series Repeater, isolator and /or fiber optic mo- dem. UDACT " ' `Universal Digital Alarm Communicator Transmitter. UZC -256 Zone Coder. Up to 256 programmable codes. OTHER ACCESSORIES 4XTM Plug -in Transmitter Module. Provides _ municipal,.box and remote. station con- nection. PS Series Batteries; the AFP- 300/400 battery range is 12 AH to 60 AH. Refer to DN -1109. ROM- AFP400 Panel software upgrade kit. Includes latest factory software (consult factory). BB -55(F) Battery Box (required for 55/60 AH). Order "F° suffix for red cabinet. ' VeriFire-CD Programming kit for PC. Includes CD, cable, and instructions. VeriFire -CDUG Same as VeriFire -CD above except it does not include the cable. Other options as listed in previous sections. Page 10 of 10 — DN- 5262.07/06/01 March 23, 2001 DN -6726 • H -240 N OT I F I E R NBG -12 � � Addressable Manual l P Pull Station with FlashScan® Section: Intelligent/Addressable Devices GENERAL PATENTED, U.S. PATENT NO. D428,351 The NOTIFIER NBG -12LX is a state -of- the -art, dual -ac- OTHER U.S. PATENTS PENDING tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any _ California ,_ NOTIFIER intelligent control panel. Because the NBG- ® State Fire 12LX is addressable, the control panel can display the c U i. 0 us Marshal exact location of the activated manual station. This leads , 7150- 0028:199 fire personnel quickly to the location of the alarm. LISTED FEATURES S692 41/;* • Maintenance personnel can open station without causing an alarm condition. • Built -in bicolor LED, which is visible through the handle of Approved the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTI- \` VATED" appears to clearly indicate the station has been operated. V • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG /3.25 mm wire). \ 1 • Semi -flush, mounts to a standard single -gang (2.125" , [5.3975 cm] minimum depth), double -gang, or 4" (10.16 cm) square electrical box. .• Smooth dual- action design. Li • Within ADA 5 lb. pull force. • Highly visible. �• Attractive shape and textured finish. i • Key reset. • Includes Braille text on station handle. \ 1 • Optional trim ring (BG -TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG -12LX stations per loop on classic protocol I' �J NIOTf Fl ER , systems. 1 • Up to 159 NBG -12LX stations per loop on FlashScan® protocol systems. • Dual -color LED blinks green to indicate normal on A FlashScan® systems. a CONSTRUCTION The NBG - 12LX Shell, door, and handle are molded of durable LEXAN® Addressable Manual Pull Station (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to Each manual station, on command from the control panel, ushi sends data to the panel representing the state of the manual latch n the down/activated ed nosition. handle latched, the switch. Two rotary decimal word "ACTIVATED" (in bright yellow) appears at the top of switches - 9 set - the handle, while a portion of the handle protrudes from to (1 159 on FlashScan® syy steemsms , 1 1 -99 9 on n CLIP LIP sys- tems). bottom of the station. To reset the station, simply rns). unlock the station with the key and pull the door open. FlashScan® is a registered trademark of NOTIFIER. LEXAN® This action resets the handle; closing the door automati is a registered trademark of GE Plastics, a subsidiary of General cally resets the switch. Electric Company. This document is not intended to be used for installation purposes. We try to keep our ISO 9001 product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 464 -7161 FAX: (203) 484-7118 E R T I F II E 6 0 N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 MIMEOS 8 MI1MIFACTURIIt DN - 6726 • 03/23/01 — Page 1 of 2 , PRODUCT LINE INFORMATION ELECTRICAL SPECIFICATIONS Model Description Normal operating voltage: 24 VDC. NBG -12LX Dual- action addressable pull station. Maximum SLC loop voltage: 28.0 VDC. Includes key locking feature. Maximum SLC loop current: 375 NA. SB -10 Surface backbox. ARCHITECTURAL/ BG -TR Optional trim ring. ENGINEERING SPECIFICATIONS INSTALLATION Manual Fire Alarm Stations shall be non - coded, with a The NBG -12LX will mount semi -flush into a single -gang, key- operated reset lock in order that they may be tested, double -gang, or standard 4" (10.16 cm) square electrical and so designed that after actual Emergency Operation, outlet box, or will surface mount to the Model SB -10 sur- they cannot be restored to normal except by use of a key. face backbox. If the NBG -12LX is being semi -flush An operated station shall automatically condition itself so mounted, then the optional trim ring (BG -TR) may be used. as to be visually detected as activated. Manual stations The BG -TR is usually needed for semi -flush mounting with shall be constructed of red - colored LEXAN® (or polycar- 4" (10.16 cm) or double -gang boxes (not with single -gang bonate equivalent) with clearly visible operating instruc- boxes). tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB -10; or semi -flush mount- I ing on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the 0 0 0 o O limits defined by the Americans with Disabilities Act (ADA) or per national /local requirements. Manual Stations shall " RI - G be Underwriters Laboratories listed. ' ' ' i il A " A kg) Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on m Terminal command from the control panel, send data to the panel Connections representing the state of the manual switch. Manual sta- bons shall provide address setting by use of rotary decimal 1 SLC ( — switches. ~' 2 SLC ( +) ,, �' The loop poll LED shall be clearly visible through the front . of the station. The LED shall flash while in the normal o J o condition, and stay steadily illuminated when in alarm. 0 U 0 -„ il : - --. t o Detail of ' - - -. - I , �� ) p ' BREAKAWAY TAB* Back of station without door. e 4 14 15 0 1 g 7 0 1 13 4. - 2 __ . __ — - 2 12 3 �- -- --- ._. —..I 3 10 9 8 7 6 9 6 7 6 i ❑ _ - G 11•111111=11I lao a�q NJq LED oa a 00 ( ROTARY DECIMAL SWITCHES c *Remove tab to select addresses I above 99 (FlashScan® systems only). Ijet: i' c ® 0 ro- fiti) I / Lg... i Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 — DN-6726 . 03/23/01 ' November 4, 2003 DN -6935 • H -202 8 ® FSP -851 and FSP-851T N OT I F I E R Intelligent Plug -in Photoelectric Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices GENERAL California NOTIFIER 851 Series intelligent plug -in smoke detectors with ,.., State Fire integral communication provide features that surpass conven- ' Marshal tional detectors. Detector sensitivity can be programmed in the ®� - 7272 - 0028:206 control panel software. Sensitivity is continuously monitored and I .I reported to the panel. Point ID capability allows each detector's LISTED CS915 address to be set with decade address switches, providing ex- (FSP - 851A, act detector locations for selective maintenance when cham- S1115 FSP - 851 TA) ber contamination reaches an unacceptable level. The FSP- MARYLAND M EA 851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of State Fire Marshal 225 -02 -E APPROVED combustion sources. Dual electronic thermistors add 135 °F Permit # 2122 (57 °C) fixed- temperature thermal sensing on the FSP -851T. FSP -851 and FSP-851T detectors are compatible with all - - -_— NOTIFIER intelligent Fire Alarm Control Panels (FACPs). _ `- FlashScan® (U.S. Patent 5,539,389) is a communication pro -°ki- tocol developed by NOTIFIER Engineering that greatly en- , =,. hances the speed of communication between analog intelligent , , devices and certain NOTIFIER systems. Intelligent devices com- municate in a grouped fashion. If one of the devices within the ( group has new information, the panel's CPU stops the group \ l poll and concentrates on single points. The net effect is response 'N . " speed greater than five times that of earlier designs. 4 < ` 6934photipg , � " FEATURES FSP -851 with - • Sleek, low - profile design. B710LP base - - • Addressable - analog communication. • Stable communication technique with noise immunity ::7,. • Low standby current. 1 , ' , ,, • Two -wire SLC connection. • FlashScan® (NFS -640, NFS -3030, AFC -600) and classic CLIP ,` ( e 1 �.' system (AFP- 100, AFP -200, AFP- 300,AFP -400, AFC-600, NFS- 8935phol.Jpg 640, AFP1010, AM2020, and NFS -3030) compatible. FSP wit ` :. ,' • Rotary, decimal addressing (1 - 99 on current classic sys- B710LP base tems, 1 - 159 on FlashScan® systems). " -- • Optional remote, single -gang LED accessory (RA400Z). Operating temperature: FSP - 851: 0 °C to 49 °C (32 °F to 120 °F); • Dual LED design provides 360° viewing angle. FSP -851T: 0 °C to 38 °C (32 °F to 100 °F). Low - temperature sig- • Visible bicolor LEDs blink green every time the detector is nal for FSP -851T at 45 °F +1- 10 °F (7.22°C +1- 5.54 °C). addressed, and illuminate steady red on alarm. UL- Listed velocity range: 0 - 4000 ft. /min. (1219.2 m /min.), • Remote test feature from the panel. suitable for installation in ducts. • Walk test with address display (an address of 121 will blink Relative humidity: 10% - 93% noncondensing. the detector LED: 12- (pause) -1) (FlashScan® systems only). Thermal ratings: fixed- temperature setpoint 135 °F (57 °C). • Built -in functional test switch activated by external magnet. DETECTOR SPACING and APPLICATIONS: • Built -in tamper - resistant feature. NOTIFIER recommends spacing detectors in compliance with • Sealed against back pressure. NFPA 72. In low airflow applications with smooth ceilings, space • Constructed of off -white Bayblend ®, designed to commer- detectors 30 feet (9.144 m) for ceiling heights 10 feet (3.048 m) cial standards, and offers an attractive appearance. and higher. For specific information regarding detector spacing, • 94 -5V plastic flammability rating. placement, and special applications, refer to NFPA 72. System • SEMS screws for wiring of the separate base. Smoke Detector Application Guide, document A05 -1003, is avail- • Optional relay, isolator, or sounder bases. able at systemsensor.com. • Listed to UL 268. FSP -851 and FSP -851T are Listed for use in ducts, but they • Backward- compatible. are NOT Listed for use inside duct smoke detector housings. See Duct Application Smoke Detectors Guide, document A05- SPECIFICATIONS 1004, available at systemsensor.com, for details on pendant - mount applications. Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B710LP base. FlashScan® is a registered trademark of NOTIFIER. Shipping weight: 5.2 oz. (147 g). Bayblend® is a registered trademark of Bayer Corporation. ER ® Is HoneywHoneywell co company This document is ISO 9001 This document s not intended to o be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice O ER T I F tr E For more information, contact NOTIFIER. Phone. (203) 484 -7161 FAX. (203) 484 -7118 MM;INEEIIE & MAM8ACIU6111G 0 NOTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEM S DN -6935 • 11/04/03 — Page 1 of 2 ELECTRICAL SPECIFICATIONS: B501A: Standard European flangeless base, ULC Listing. Voltage range: 15 - 32. volts DC peak. B501 BH(A): Sounder base, includes B501(A) base above. Standby current (max. avg.): 250 pA @ 24 VDC (with no com- B501 BHT(A): Same as B501 BH(A), but includes temporal munication enabled); 360 pA @ 24 VDC (one communication sounder. every 5 seconds with LED enabled). B224RB(A): Intelligent relay base. LED current (max.): 6.5 mA @ 24 VDC ( "ON "). B224BI(A): Intelligent isolator base. Isolates SLC, from loop BASES AVAILABLE: shorts. B710LP: 6.1" (15.5 cm) diameter. Accessories: B501: 4.1" (10.4 cm) diameter. F110: Retrofit replacement flange for BX -501 base. Converts B501 BH or B501BHT: Sounder base assembly. Includes B501 BX -501 base for use with FlashScan® detectors. base. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 single -gang electrical box. Supported by B710LP(A) and mm Relay type: Form -C. Rating: 2.0 A @ 30 VDC resis- B501(A) bases only. tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. SMK400: Surface mounting kit provides for entry of surface Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). wiring conduit. For use with B501(A) base only. B224BI Isolator Base: Dimensions :, 6.2" (15.748 cm) x 1.2" RMK400: Recessed mounting kit. For use with B501(A) base (3.048 cm). Maximum: 25 devices between isolator bases. only. INSTALLATION SMB600: Surface mounting kit for use with B710LP(A). FSP -851 plug -in detectors use a separate base to simplify in- BCK-200B: Black detector covers, box of 10. stallation, service, and maintenance. A special tool allows main- MO2 -04 -01: Test magnet. tenance personnel to plug in and remove detectors without us- MO2- 09 -00: Test magnet with telescope stick. ing a ladder. XR2B: Detector removal tool. Allows installation and/or removal Mount base on an electrical backbox which is at least 1.5" (3.81 of FlashScan® Series detector heads from base in high ceiling cm) deep. Suitable mounting base boxes include: installations. • 4.0" (10.16 cm) square box. 155- 127 -000: Detector removal tool without pole. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. XP -4: Extension pole for XR2B Comes in three 5 -ft. sections. • Single -gang box (except relay or isolator base). Detector Guards: • With 8501BH or B501BHT base, use a 4.0" (10.16 cm) NOTE: Some guards listed below may not be applicable to FSP models. square box. • With 8 th B224RB or base use a 3.5" (8.9 cm) octago- SDG -773: Smoke detector guard; cover is 7.0" (17.78 cm) nai box, or a 4.0" (10.16 cm) ctagoaal or square , box. square x 3.0" (7.62 cm) deep. This guard is mechanically corn - patible with NOTES: 1) Because of the inherent supervision provided by the 851 (file UL S5515). !t is UL- compatibility listed with the FSP - SLC loop, end - of - line resistors are not required. Wiring "T- -taps" STI 9601: Low - profile, flush - mount smoke detector guard, wire." or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN - 2243 STI 9602: Low - profile, surface mount, smoke detector guard, (ISO - )0 for device limitations between isolator modules and isola wire.* for bases. STI 9609: High - profile, flush - mount, smoke detector guard, wire.* PRODUCT LINE INFORMATION STI 9605: High - profile, surface- mount, smoke detector guard, wire.* NOTE: "A" suffix indicates ULC Listed model. STI 9604: Flush -mount heat detector guard, wire." FSP -851: Low - profile intelligent photoelectric sensor. Must be STI 9610: Surface -mount heat detector guard, wire.* mounted to one of the bases listed below. *For dimensions and additional information on ST/ Steel Web Stop - FSP-851A: Same as FSP -851 but with ULC Listing. pers, see data sheet DN - 4936. FSP -851T: Same as FSP -851 but includes a built -in 135 °F STI - 8200 -SS: Flush -mount stainless steel smoke detector guard (57 °C) fixed- temperature thermal device. (compatibility pending). FSP- 851TA: Same as FSP -851T but with ULC Listing. STI-8230-SS: Surface -mount stainless steel smoke detector Bases: guard (compatibility pending). B710LPBP: Standard U.S. low - profile base, pkg. of 10 B710LPA: Standard U.S. low - profile base, ULC Listing. B501BP: Standard European flangeless base, pkg. of 10. REMOTE ANNUNCIATOR WIRING DIAGRAM 8833addcwmf g 9 �0 �� 1 8 0 CONTR { -t - foRN 6 ` 1 2 6 PAN � � = • f 1 130e ��� II �� i 4 1a D, ��� �1, 1 1 O ' 2. 6 G `--,.1 1/41.i....../r ■ address dial on back of detector _, OPTIONAL RETURN LOOP - ` Page 2 of 2 - DN -6935 • 11/04/03 November 4, 2003 DN -6936 • H -211 FST -851 Series N OT I F I E R° Intelligent Thermal (Heat) Detectors with FlashScan® Section: Intelligent/Addressable Devices GENERAL NOTIFIER 851 Series intelligent plug -in smoke detectors with 4> M EA integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in 323 -02 -E the control panel software. Sensitivity is continuously moni- LISTED CS630 APPROVED tored and reported to the panel. Point ID capability allows each (ML255) detector's address to be set with decade address switches, S747 I! ! California (FST - 851A, State Fire providing exact detector locations for selective maintenance FST 851HA, a Marshal when chamber contamination reaches an unacceptable level. FST - 851 RA) FST Series thermal detectors use an innovative thermistor i-• "• -I 7270 - 0028:196 sensing circuit to produce 135 °F /57 °C fixed- temperature (FST - 851) and rate -of -rise thermal detection (FST -851R) in a low - profile package. FST -851 H provides fixed high - temperature de- tection at 190 °F /88 °C. These thermal detectors provide cost effective, intelligent property protection in a variety of applica- -, `•i ; , c > , tions. FST -851 Series detectors are compatible with all NOTIFIER intelligent Fire Alarm Control Panels (FACPs). - FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices and certain NOTIFIER systems. Intelligent de- - , Imo, vices communicate in a grouped fashion. If one of the devices i within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is FST - 851 in B701 LP base response speed greater than five times that of earlier designs. • Sealed against back pressure. FEATURES • Plugs into separate base for ease of installation and main- • Sleek, low - profile, stylish design. tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. • State -of- the -art thermistor technology for fast response. SEMS screws for wiring of the separate base. • • Rate-of-rise model (FST -851 R), 15 °F (8.3 °C) per minute. • Constructed of off -white Bayblend ®, designed to commer- • Factory preset at 135 ° F (57 °C); high- temperature model at cial standards, and offers an attractive appearance. 190 °F (88 °C). • 94 -5V plastic flammability rating. • Addressable by device. • Remote LED output connection to optional RA400Z remote • FlashScan® (NFS- 640, NFS -3030, AFC -600) and classic CLIP LED annunciator. system (AFP -100, AFP -200, AFP -300, AFP -400, AFC -600, Optional sounder, relay, and isolator bases. • NFS -640, AFP1010, AM2020, and NFS -3030) compatible. • • Rotary, decimal addressing (1 — 99 on current classic sys- Optional recessed (RMK400) or surface (SMK400) base tems, 1 — 159 on FlashScan® systems). mounting kits. • Two-wire SLC connection. SPECIFICATIONS • Visible LEDs `blink" every time the unit is addressed. Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in • 360 ° -field viewing angle of the visual alarm indicators (two B501 base, 6.1" (15.5 cm) diameter installed in B710LP base. bicolor LEDs). LEDs blink green in Normal condition and Shipping weight: 4.8 oz. (137 g). turn on steady red in Alarm. Operating temperature range: FST -851, FST -851R: —20 °C • Integral communications and built -in device-type identification. to 38 °C (-4 °F to 100 °F); FST -851H: —20 °C to 66 °C ( -4°F to • Remote test feature from the panel. 150 °F). • Built -in functional test switch activated by external magnet. Detector spacing: UL approved for 50 ft. (15.24 m) center to • Walk test with address display (an address of 121 will blink center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. the detector LED 12- (pause) -1). Relative humidity: 10% — 93% noncondensing. • Low standby current. Thermal ratings: fixed- temperature setpoint 135 °F (57 °C), • Listed to UL 521. rate -of -rise detection 15 °F (8.3 °C) per minute, high tempera- • Backward- compatible. ture heat 190 °F (88 °C). • Built -in tamper- resistant feature. • Designed for direct - surface or electrical -box mounting. FlashScan® is a registered trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. T a Honeywell company. ISO 9001 This document is not intended ed d to to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. C E R T I F I E D For more information, contact NOTIFIER. Phone' (203) 484 -7161 FAX: (203) 484 -7118 ENGINEERING 8 MANUFACTURING 0 NOTI F I ER 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN -6936 • 11/04/03 — Page 1 of 2 ELECTRICAL SPECIFICATIONS: FST -851H: Intelligent high - temperature thermal detector. Voltage range: 15 - 32- volts DC peak. FST -851 HA: Same as FST-851H but with ULC Listing. Standby current (max. avg.): 200 pA @ 24 VDC (without corn- Bases: . munication); 300 pA @ 24 VDC (one communication every 5 B710LPBP: Standard U.S. low - profile base, pkg. of 10. seconds with LED enabled). ` LED current (max.): 6.5 mA @ 24 VDC ( "ON "). B710LPA: Standard U.S. low - profile base, ULC Listing. BASES AVAILABLE: B501BP: Standard European flangeless base, pkg. of 10. B710LP: 6.1" (15.5 cm) diameter. B501A: Standard European flangeless base, ULC Listing. B501: 4.1 (10.4 cm) diameter. B501 BH(A): Sounder base, includes B501(A) base above. B501 BH or 8501 BHT: Sounder base assembly. Includes B501 8501 BHT(A): Same as B501 BH(A), but includes temporal base. sounder. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 B224RB(A): Intelligent relay base. mm Relay type: Form -C. Rating: 2.0 A @ 30 VDC resis- B224BI(A): Intelligent isolator base. Isolates SLC from loop tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. shorts. Dimensions: 6.2" (15.748 cm) x 1.2° (3.048 cm). Accessories: B224BI Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" F110: Retrofit replacement flange for BX -501 base. Converts (15.748 cm). Maximum: 25 devices between isolator bases. BX -501 base for use with FlashScan® detectors. See Note 2 under Installation. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. APPLICATIONS single -gang electrical box. Supported by B710LP(A) and Use thermal detectors for protection of property. For further B501(A) bases only. information, go to systemsensor.com for manual 156- 407 -00, SMK400: Surface mounting kit provides for entry of surface Applications Manual for System Smoke Detectors, which pro- wiring conduit. For use with B501(A) base only. • vides detailed information on detector spacing, placement, RMK400: Recessed mounting kit. For use with B501(A) base Zoning, wiring, and special applications. only. INSTALLATION SMB600: Surface mounting kit for use with B710LP(A). The FST Series plug -in intelligent thermal detector uses a sepa- BCK-200B: Black detector covers, box of 10. rate base to simplify installation, service, and maintenance. MO2 -04 -01: Test magnet. Installation instructions are shipped with each detector. MO2 -09 -00: Test magnet with telescope stick. Mount base (all base types) on an electrical backbox which is XR2B: Detector removal tool. Allows installation and /or removal at least 1.5" (3.81 cm) deep. Suitable boxes include: of FlashScan® Series detector heads from base in high ceil- • 4.0" (10.16 cm) square box. ing installations. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. T55- 127 -000: Detector removal tool without pole. • Single -gang box (except relay or isolator base). XP-4: Extension pole for XR2B. Comes in three 5 -ft. sections. • With B501BH or B501BHT base, use a 4.0" (10.16 cm) Detector Guards: square box. NOTE Some guards listed below may not be applicable to FST Series. • With B224RB or B224BI base, use a 3.5" (8.89 cm) or 4.0" STI 9601: Low - profile, flush -mount smoke detector guard, wire.* (10.16 cm) octagonal box, or a 4.0" (10.16 cm) square box. STI 9602: Low - profile, surface - mount, smoke detector guard, NOTES: 1) Because of the inherent supervision provided by the wire.* SLC loop, end - of - line resistors are not required. Wiring "T - taps" STI 9609: High - profile, flush - mount, smoke detector guard, wire.* or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN - 2243 STI 9605: High - profile, surface mount, smoke detector guard, (ISO - X) for device limitations between isolator modules and isola wire.* tor bases. STI 9604: Flush -mount heat detector guard, wire.* PRODUCT LINE INFORMATION STI 9610: Surface -mount heat detector guard, wire.* "For dimensions and additional information on STI Steel Web Stop - NOTE: "A" suffix indicates ULC Listed model. pers, see data sheet DN -4936. FST -851: Intelligent thermal detector. Must be mounted to one STI- 8200-SS: Flush -mount stainless steel smoke detector of the bases listed below. guard (compatibility pending). FST -851A: Same as FST -851 but with ULC Listing. STI - 8230 -SS: Surface -mount stainless steel smoke detector FST-851R: Intelligent thermal detector with rate -of -rise feature. guard (compatibility pending). FST- 851RA: Same as FST -851R but with ULC Listing. REMOTE ANNUNCIATOR WIRING DIAGRAM + - Mel - 6833addr wmf + / I NI 1 8 9 \ , a 9 6 ,Z 6 5 Control /. ,� iri,..k.v,..0 4 13 5 01 5 3� 1 o Panel \. i � 1 \ill' ii - N . II ■ address dial on - / 1 back of detector + S E 6/7 OPTIQIV�4L WIRING / J YL / . 8714wi2.hf Page 2 of 2 - DN -6936 • 11/04/03 Conventional Gamewell [ Reflective Beam WORLDWIDE S moke Detector Description Gamewell's Reflective Beam Smoke Detector 72223 -160 and rAr 72223 -330 system consists of a single infra -red transceiver r, c . ,• and a reflective prism. The signal generated in the transmitter element and reflected by the pnsm back to the receiver element is analyzed for the presence of smoke. The internal - l microprocessor determines an alarm condition when a predetermined level is reached. The system is designed to be mounted so that the beam will project between 1 foot and 2 feet below and parallel to the ceiling. Lateral detection may be up to 30 feet to either side of the beam, providing a maximum total area coverage of 19,800 square feet. (60'x330'). f; ' Engineer's Specifications Approvals UL Listed, CSFM, MEA Approved The projected beam type smoke detector shall be a 4 -wire 12/ 24 VDC device to be used with U.L. listed separately supplied Features 4-wire control panels only. Unit shall be listed to U.L. 268 and • shall consist of an integrated transmitter and receiver. The Models for ranges of detector shall operate between a range of 15 - 330ft. The 15 - 160 feet temperature range of the beam shall be -22 °F to 131 °F. The 160 -330 feet beam detector shall feature automatic gain control which will Easy alignment • compensate for gradual signal deterioration from dirt accumulation on lenses. The unit shall include a wall • Calibrated obscuration test filters included mounting bracket. Testing shall be carried out using a • Selectable alarm thresholds - 25 %, 35 %, 50% calibrated test filter. The projected beam type smoke detector • Microprocessor controlled shall be Gamewell model 72223 -160 (160ft.) or 72223 -330 Low current draw • (330ft.). • Selectable automatic reset • Automatic gain control • 12VDC or 24VDC operation • Status LEDs • Separate trouble contacts CS -2154 Rev.0402 -4 Page 1 Operational Specifications Environmental Specifications Range Temperature -22° F to 131° F ( -20° C to 55° C) 15ft. to 330ft. (length) 5m to 100m Humidity 10 -93% RH noncondensing Fault Condition (Trouble) Electrical Specifications 90% or more obscuration, Automatic gain control limit, Voltage 10 to 30 VDC Maximum Improper initial alignment Standby Current .004A maximum Integral alignment aid - Prism targeting mode Alarm/Trouble Current .014A maximum Relay Contacts Current Rating .5A at 30 VAC /DC Alarm indicator - Red LED Reset Time 5 seconds maximum Trouble indicator - Green LED Start-up Time 10 seconds Optical Wavelength 880nm Smoke Detector Spacing On smooth ceilings, up to 60 ft between projected beams and not more than one -half that spacing between a pro- Physical Specifications jected beam and a sidewall. Other spacing may be used depending on ceiling height, airflow characteristics, and Dimensions 8 1/4" x 4 1/2" x 4 3/4" response requirements. See NFPA 72 Finish Gray /Black Housing ABS Weight approx 1.5 lbs. Ordering Information Model Number Description 72223 -160 Reflective beam 160ft. (50R) 72223 -330 Reflective beam 330ft. (100R) 72224 Prism - replacement Specifications and wiring information are provided for information only and are believed to be accurate Gamewell assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell. /� The Gamewell Company Voice (508) 231 -1400 Gamewel 60 Pleasant St. 888 - FIREBOX • (888) 347 -3269 WORLDWIDE Ashland, MA 01721 FAX (508) 231 -0900 www.gamewell.com ©Gamewell 2002 CS - 2154 Rev.0402 - 4 Paget September 12, 2001 DN -6720 - H -220 N QT 1 F 1 E R® FMM, FZM, and FDM Series Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices GENERAL _ California ,` State Fire Four different monitor modules are available for NOTIFIER in- Marshal telligent controls to suit a variety of applications. Monitor modules are used to supervise a circuit of dry- contact input [ " "I 7300- 0028:202 devices, such as conventional heat detectors and pull sta- LISTED CS669 tions, or monitor and power a circuit of two -wire smoke de- S635 tectors (FZM -1). MARYLAND M EA FMM - — is a standard -sized module (typically mounts to State Fire Marshal a 4" [101.6 mm] square box) that supervises either a Class Permit # 2020 143 -01 -E (FDM -1) A (Style D) or Class B (Style B) circuit of dry- contact input (except FDM - 1) 457 -99 -E (FMM - 1, devices. Approved FMM - 101, FZM - 1) FMM - 101 — is a miniature monitor module (a mere 1.3" n n \ (33.02 mm) H x 2.75" (69.85 mm) W x 0.5" (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM -101 to often be mounted in a single- 0 O gang box behind the device it's monitoring. v O p FZM - — is a standard -sized module used to monitor and y / '° supervise compatible two -wire, 24 volt, smoke detectors on ® 9 78 0 111 a Class A (Style D) or Class B (Style B) circuit. ® 8 45 11 1 M FDM - — is a standard -sized dual monitor module used to '° 2 5 2 13 a 9 monitor and supervise two independent two -wire initiating ® 7 TEN 6,0 ` 78 1 ® and FMM-1 device circuits (IDCs) at two separate, consecutive addresses Eil 6 3 in intelligent, two wire systems. I 5 3 2 C . 4 la FlashScan® (U.S. Patent 5,539,389) is a new communi- ' 0 ONE cation protocol developed by NOTIFIER Engineering that LOOP ADDRESS greatly enhances the speed of communication between ana- 0 log intelligent devices. Intelligent devices communicate in a C I O 0 0 grouped fashion. If one of the devices within the group has , new information, the panel CPU stops the group poll and U U concentrates on single points. The net effect is response speed greater than five times that of other designs. l FlashScan® is a registered trademark of NOTIFIER. FMM -1 MONITOR MODULE 1 5 0 �� • Built -in type identification automatically identifies this de- detail of FDM - 'al 8 3 \���;z 1 vice as a monitor module to the control panel. — note "ones" 7 � 0 1 5 1 43 2 Le •Powered directly by two -wire SLC loop. No additional addresses ar e e/ � 8 y power required. 0, 2, 4, 6, 8 only r ® 4 "� 3 [ , • High noise (EMF /RFI) immunity. ID 5 2 � 0 � 4 0 ONES -+ • SEMS screws with clamping plates for ease of wiring. ( ILOOP ADDRESS • Direct -dial entry of address 01 – 159 (01 – 99 on tradi- tional systems). • LED flashes green during normal operation (this is a pro- FMM - Applications — Use to monitor a zone of four - grammable option) and latches on steady red to indicate wire smoke detectors, manual fire alarm pull stations, alarm. waterflow devices, or other normally -open dry- contact alarm The FMM -1 Monitor Module is intended for use in intelli- activation devices. May also be used to monitor normally - gent, two -wire systems, where the individual address of each open supervisory devices with special supervisory indica- module is selected using the built -in rotary switches. It pro- tion at the control panel. Monitored circuit may be wired as vides either a two -wire or four -wire fault - tolerant Initiating an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit (IDC) for normally- open - contact fire alarm and Device Circuit. A 47K ohm End -of -Line Resistor (provided) supervisory devices. The module has a panel - controlled LED terminates the Style B circuit. No resistor is required for su- indicator. The FMM -1 can be used to replace MMX -1 mod- pervision of the Style D circuit. Maximum IDC loop length is ules in existing systems. 2,500 ftJ762 m (20 ohms maximum). This document is not intended to be used for installation purposes We try to keep our ISO 9001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484-7118 C E R T I F I E D I N OTI Fl E R' 12 Clintonville Road, Northford, Connecticut 06472 BV6IREEHIN6 8 MANOf CIIMINI DN -6720. 09/12/01 — Page 1 of 6 FMM - Operation — Each FMM -1 uses one of 159 avail- and the status (open /normal /short) of its Initiating Device able module addresses on an SLC loop. It responds to regu- Circuit (IDC). lar polls from the control panel and reports its type and the FMM - 101 Specifications , status (open /normal /short) of its Initiating Device Circuit (IDC). Nominal operating voltage: 15 to 32 VDC. A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm Maximum operating current: 375 pA. (subject to current limitations on the loop). EOL resistance: 47K ohms. FMM - Specifications Temperature range: 32 °F to 120 °F (0 °C to 49 °C). Nominal operating voltage: 15 to 32 VDC. • Humidity range: 10% to 93% noncondensing. Maximum current draw: 5.1 mA (LED on). Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide Maximum operating current: 375 pA (LED flashing). x 0.5" (12.70 mm) deep. EOL resistance: 47K ohms. Wire length: 6" (152.4 mm) minimum. Temperature range: 32 °F to 120 °F (0 °C to 49 °C). FZM -1 INTERFACE MODULE Humidity range: 10% to 93% noncondensing. • Supports compatible two -wire smoke detectors. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x • Supervises IDC wiring and connection of external power 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square source. x 2.125" (53.975 mm) deep box. • High noise (EMF /RFI) immunity. FMM -1 O1 MINI MONITOR MODULE • SEMS screws with clamping plates for ease of wiring. • • Built -in type identification automatically identifies this de Direct -dial entry of address (01-159). vice as a monitor module to the AFC -600. ▪ LED flashes during normal operation (this is a program- • Powered directly by two -wire FACP. No additional power mable option). required. • LED latches steady to indicate alarm on command from • High noise (EMF /RFI) immunity. control panel. • Tinned, stripped leads for ease of wiring. The FZM -1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of • Direct -dial entry of address (01 -159). each module is selected using built -in rotary switches. This module allows intelligent panels to interface and monitor two - 1415 0 1 ADDRESS 0 1 wire conventional smoke detectors. It transmits the status 13 �, 2 o 2 (normal, open, or alarm) of one full zone of conventional de- 12 3 LO OP 3 tectors back to the control panel. All two wire detectors be 11 a 4 ing monitored must be UL compatible with the module. The 1 0 5 5 E FZM -1 has a panel - controlled LED indicator and can be used 9 8 7 6 9 8 7 6 3 to replace MMX -2 modules in existing systems. TENS ONES o FZM - Applications — Use the FZM -1 to monitor a n n ri n F. zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or O - CI Y g A) circuit (maximum C resistance ohms). } ap ELR across terminals 8 and 9 for Style D application. FZM cir -1 Operation ID — loop Each FZM -1 uses is 25 one of 159 avail- Install able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the I I I I status (open /normal /short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- The FMM -101 Mini Monitor Module can be installed in a tion with the control panel. The LED latches steady on alarm single -gang junction directly behind the monitored unit. Its (subject to current limitations on the loop). small size and light weight allow it to be installed without rigid FZM - Specifications mounting. The FMM -101 is intended for use in intelligent, two -wire systems where the individual address of each mod- Nominal operating voltage: 15 to 32 VDC. ule is selected using rotary switches. It provides a two -wire Maximum current draw: 5.1 mA (LED on). initiating device circuit for normally- open - contact fire alarm Maximum operating current: 255 pA (LED flashing). and security devices. The FMM -101 can be used to replace MMX -101 module in existing systems. EOL resistance: 3.9K ohms. FMM - 101 Applications — Use to monitor a single de- External supply voltage (between Terminals T3 and T4): vice or a zone of four -wire smoke detectors, manual fire DC voltage: 18 to 28 volts power limited. Ripple voltage: alarm pull stations, waterflow devices, or other normally -open 0.1 VRMS maximum. Current: 90 mA per module maximum. dry- contact devices. May also be used to monitor normally- Temperature range: 32 °F to 120 °F (0 °C to 49 °C). open supervisory devices with special supervisory indication Humidity range: 10% to 93% noncondensing. at the control panel. Monitored circuit/device is wired as an D 4.5" (114.3 mm) high x 4" (101.6 mm) wide x NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square End -of -Line Resistor (provided) terminates the circuit. x 2.125" (53.975 mm) deep box. FMM - 101 Operation — Each FMM -101 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type , Page 2 of 6 - DN -6720 •09/12/01 FDM -1 DUAL MONITOR MODULE INSTALLATION The FDM -1 Dual Monitor Module is intended for use in in- FMM -1, FDM-1, and FZM-1 modules mount directly to a stan- telligent, two -wire systems. It provides two independent two- dard 4" (101.6 mm) square, 2.125" (53.975 mm) deep, electri- wire initiating device circuits (IDCs) at two separate, consecu- cal box. They may also be mounted to the SMB500 surface - tive addresses. It is capable of monitoring normally open mount box. Mounting hardware and installation instructions are contact fire alarm and supervisory devices; or either normally provided with each module. All wiring must conform to appli- open or normally closed security devices. The module has a cable local codes, ordinances, and regulations. These mod - single panel - controlled LED. NOTE: The FDM -1 provides ules are intended for power - limited wiring only. two Class B (Style Y) IDC circuits ONLY. Class A (Style Z) The FMM -101 module is intended to be wired and mounted IDC circuits are NOT supported in any application. without rigid connections inside a standard electrical box. All FDM - Specifications wiring must conform to applicable local codes, ordinances, Normal operating voltage range: 15 to 32 VDC. and regulations. Maximum current draw: 5.7 mA (LED on). PRODUCT LINE INFORMATION Maximum operating current: 750 pA (LED flashing). Model Description EOL resistance: 47K ohms. FMM - Monitor module. Maximum IDC wiring resistance: 1,500 ohms. FMM -101 Monitor module, miniature. Temperature range: 32° to 120 °F (0° to 49 °C). FZM -1 Monitor module, two -wire detectors Humidity range: 10% to 93% (non- condensing). FDM -1 Monitor module, dual, two independent Class Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x B circuits. 2.125" (53.975 mm) deep. SMB500 Optional surface -mount backbox. FDM - 1 Automatic Addressing — The FDM -1 auto- ARCHITECTS' /ENGINEERS' matically assigns itself to two addressable points, starting SPECIFICATIONS with the original address. For example, if the FDM -1 is set to address "56 °, then it will automatically assign itself to ad- Specifications of these and all NOTIFIER products are avail - dresses "56° and "57 ". NOTE: "ones" addresses on the able from NOTIFIER. FDM -1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. zisw Avoid duplicating addresses on the system. „. /\ _47 () 'Os' Si I I 4 I % I I 4N %%%'%'%'%, 4 I I 1 I I I 14. 11 0 N OTIFlER' I CAUTION DE- ENERGIZE UNIT PRIOR TO SERVICING ” Face Plate for FMM -1, FZM -1, and FDM -1 ll MOUNTING DIAGRAMS for slandord -sized a ° = �` �' 4 niodu /es � 0 m o � o i o I�m \ � Yi 1 c,___ 1 ,,,,,,..,.efr ....,, ,,, , r'il . 0 9 3 ---`-% ',--- 9 1 il 1, v. o - ic) I 0 () DN -6720. 09/12/01 — Page 3 of 6 WIRING DIAGRAMS The following wiring diagrams are included: 1) FDM -1, typical dual two -wire Style B initiating device circuit configuration. 2) FMM -101, typical two -wire Style B initiating device circuit configuration. 3) FMM -1, typical two -wire initiating circuit configuration, NFPA Style B. 4) FMM -1, typical four -wire fault - tolerant initiating circuit configuration, NFPA Style D. 5) FMM -1, typical two -wire initiating circuit configuration for security systems (with alarm versus short capability). 6) FZM -1, interface two-wire conventional detectors, NFPA Style B. 7) FZM -1, interface two-wire conventional detectors, NFPA Style D. 8) FRM -1, relay control module used to disconnect a power supply. WIRING DIAGRAM: FDM -1 Fig. 1 FDM -1: Typical dual two -wire Style B initiating device circuit configuration. Two Initiating Device Circuits ( —) ■ (L & H) TO Next ; �� + �� each power - limited to Device ( + ) ( —) FROM Panel 230 pA max. @ 12 VDC max. ' ��� ( +) or Previous ■ MONITOR • / 4 Device 47K EOL 0 MODULE Resistor Communication Line ELR -47K �� 9 0 0 jI l _ , 32 VDC maximum. 01 ({ r Twisted -pair is ti) 1 l� (+ recommended. H 7 TENS 2 El 47K EOL [ • 6 _ 3 I • All wiring shown is supervised Resistor L 5 ' 4 10 ON and power limited. ELR -47K r LOOP ADDRESS p 0 • Connect modules to listed compatible Q O O 9 NOTIFIER control panels only. U U . • ANY NUMBER of UL Listed contact closure devices may be used. 6622wn.wmf • DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. • Install contact closure devices per manufacturer's installation instructions. . ( + ) TO ► NEXT H DEVICE UL LISTED BLACK ■ 4 RED Compatible ( -) ( +) FMM -101 Control 5 5 6 - 7 8, 9 3 1 2 4 Panel , 2 2 ' 1 � 0 15 0 ( +)( —) 0 VIOLET ► 4 YELLOW WIRING DIAGRAM: FMM -101 0 47K EOL INCLUDED Fig. 2 FMM -101: Typical two -wire Style B initiating device circuit configuration. 6720w1r1 wmf Page 4 of 6 — DN -6720 •09/12/01 June 3, 2002 DN -5765 • J -120 NOTIFIER Wheelock RSS and RSSP Series Single- and Multi - Candela Strobes and Strobe Plates Section: AudioNisual Devices GENERAL Pm California Wheelock's patented RSS Series Strobes and RSSP Series UL ten; State Fire Strobe Plates have lower current draw and zero inrush o , - Marshal while maintaining outstanding performance, reliability, and f " - 9 7125 - 0785:141 cost effectiveness. These versatile devices will satisfy virtu- LISTED CS 356 ally all requirements for indoor wall- or ceiling -mount appli- S5391 cations. Strobe EA Strobe options for wall -mount models include 15/75 cd or 4 ti f Wheelock's patented SPEC1FIRET"" multi - candela strobe 151 -92 -E Vol. XIX, XX Approved with field- selectable candela settings of: 15, 30, 75, or 110 Vol. XXIV (RSS - 24MCW - FR, - FW) cd. Ceiling -mount models are available in 15, 30, 75, or 100 cd intensities. All models may be synchronized when used in conjunction with the Wheelock SM or DSM Sync Modules. Synchro- ��-�,��;,i ' l ha�k 2 .�1'1'Yki?iY� S^°%� y nized strobes can eliminate possible restrictions on the num- ber of strobes in the field of view. Wheelock's synchronized • �, 1''- strobes offer an easy way to comply with ADA recommen -' i ? - - -� -° � dations concerning photosensitive epilepsy as well as meet- a ' ing the requirements of NFPA 72 (1999). t Wheelock's RSS Series Strobes employ a patented integral strobe mounting plate that can be mounted to single -gang, , double-gang, 4" 10.16 cm square, 100 mm European, or the SHBB surface backbox.. If the flush backbox has side or � top space between it and the finished � a ; P P a d e wall, the NATP (Noti- fication Appliance Trim Plate) may be used It provides an additional 0.65" 16.51 rnm of trim for the appliance. An attractive cover plate is provided for a clean, finished ap- k { pearance on all models. y ' The RSSP Series Multi - Candela Strobe Plates are a cost- RSS - 24MCW -FR 5 ' 65D "'" " �' effective way to retrofit required strobe appliances to bells, horns, chimes, multitones, or speakers. They mount easily to • Low current draw with temperature compensation to re- standard 4" (10.16 cm) backboxes, or for surface mounting, duce power consumption and wiring costs. use with Wheelock's SBL2 surface backbox. • Strobes produce one flash per second over the regulated For weatherproof RSS Series model, see Wheelock data sheet voltage range. S9004. • 12 and 24 VDC models with wide new UL "regulated voltage" ranges using filtered (DC) or unfiltered VRMS input FEATURES voltage. • ADA/NFPA /ANSI compliant. Meets OSHA 29, Part • Synchronize with Wheelock SM or DSM sync modules. 1910.165. • Zero inrush above peak. • Wall -mount or ceiling -mount models available. • Compatible with all Wheelock two -wire products. • Wall -mount models are available in 15/75 cd or with field- • Fast installation with In /Out screw terminals using #12 selectable candela settings of 15, 30, 75, or 110 cd (multi- AWG (3.25 mm to #18 AWG (0.75 mm wires. candela models). • For RSS Series mounting: patented integral strobe mount- • Ceiling -mount models are available in 15, 30, 75, or 100 cd. ing plate for single -gang, double -gang, 4" (10.16 cm) • Low current draw with temperature compensation to re- square, or 100 mm European backboxes. Wheelock's duce power consumption and wiring costs. SHBB shallow backbox is used for surface mounting. • For RSSP Series mounting: use standard 4" (10.16 cm) SPECIFIRETM' is a trademark of Wheelock Inc LEXANI is a backboxes or for surface mounting, Wheelock's SBL2 registered trademark of GE Plastics, a subsidiary of General Elec- surface backbox. tic Company. NOTIFIER® is an operation of Honeywell. This document is not intended to be used for installation purposes We try to keep our ISO 9001 product information up -to -date and accurate We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice For more information, contact NOTIFIER. Phone. (203) 484 -7161 FAX' (203) 484 -7118 o E Fair- P 1 Era NOTI Fl ER' 12 Clintonville Road. Northford, Connecticut 06472 BV6MN6NlN1UFABID61N6 DN- 5765.06/03/02 — Page 1 of 4 GENERAL NOTES • "Regulated voltage range" is the newest terminology used • Strobes are designed to flash at 1 flash per second minimum by UL to identify the voltage range. Prior to this change, UL over the regulated voltage range. Note that NFPA 72 (1999) used the terminology `Listed voltage range." specifies a flash rate of 1 to 2 flashes per second and ADA ®WA RN/ING! guidelines specify a flash rate of 1 to 3 flashes per second. PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED • All candela ratings represent minimum effective strobe inten- INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, sity based on" UL 1971. . SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO • RSS /RSSP Series strobe products are listed under UL 1971 COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, for indoor use with a temperature range of 32 ° F to 120 ° F (0 ° C CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER to 49 ° C) and maximum humidity of 93% (± 2 %). APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. ORDERING INFORMATION Model Number Input Reg. Volltage Strobe Candela Average Current` (Amps) Voltage vrci YR (cd) @ 24 VDC Mounting Options'° Multi - Candela Wall -Mount Strobes: 15 cd 30 cd 75 cd 110 cd RSS - 24MCW -FR 24 VDC 16.0 – 33 0 15 / 30 / 75 / 110 0.050 0.081 0.133 0.161 B, D, E, F, G H, J, N, 0, R, X RSS - 24MCW -FW 24 VDC 16.0 – 33.0 15 / 30 / 75 / 110 0.050 0.081 0.133 0.161 B, D, E, F, G, H, J, N, 0, R, X Single - Candela Wall - Mount Strobes: RSS- 241575W -FR 24 VDC 16.0 – 33.0 15 (75 on axis) 0.065 B, D, E, F, G, H, J, N, 0, R, X RSS- 121575W -FR 12 VDC 8.0 –17.5 15 (75 on axis) 0.170 B, D, E, F, G, H, J, N, 0, R, X Single Candela Ceiling - Mount Strobes: RSS- 2415C -FW 24 VDC 16.0 – 33.0 15 0.072 B, D, E, F, G, H, J, N, 0, R, X RSS- 2430C -FW 24 VDC 16.0 – 33.0 30 0.102 B, D, E, F, G, H, J, N, 0, R, X RSS- 2475C -FW 24 VDC 16.0 – 33.0 75 0.205 B, D, E, F, G, H, J, N, 0, R, X RSS- 24100C -FW 24 VDC 16.0 – 33.0 100 0.238 B, D, E, F, G, H, J, N, 0, R, X Wall - Mount Strobe Plates:•••• 15 cd 30 cd 75 cd 110 cd RSSP - 24MCW -FR 24 VDC 16.0 – 33.0 15 / 30 / 75 / 110 0.050 0.081 0.133 0.166 D, E, Z RSSP- 241575W -FR 24 VDC 16.0 – 33.0 15 (75 on axis) 0.065 D, E, Z RSSP- 121575W -FR 12 VDC 8.0 – 17.5 15 (75 on axis) 0.170 D, E, Z Synchronization Modules: SM- 12/24 -R 24 VDC — — 0.025 W DSM- 12/24 -R 24 VDC — — 0.038 W NOTES: 1) SUFFIXES USED ABOVE: W = Wall mounting; C = Ceiling mounting; F = Fire lettenng; Rat end = Red; W at end = White. EXAMPLES: RSS- 241575W -FR (Wall mounting – Fire lettering, Red); - RSS- 2415C -FW (Ceiling mounting – Eire lettering; White). 2) SPECIAL PLATE: NATP Trim Plate provides 0.65" (16.51 mm) additional trim for the appliance. Available in red only. ' Series RSS and RSSP wall -mount models are offered in red only. Series RSS ceiling -mount models are offered in white only. *' Average current per actual Wheelock production testing Listed VDC. For rated average and peak current across the UL regulated voltage range for both filtered DC and unfiltered VRMS, see the Wheelock installation instructions. ° °* For descriptions of MOUNTING OPTIONS, refer to NOTIFIER data sheet DN -6111, derived from Wheelock #S7000. *"`* Compatible Wheelock audibles /speakers for RSSP Strobe Plates are as follows: multitone appliances (AMT, MT); horns (AH, NH); motor bells (MB- G6/G10); speakers (ET- 1010/1080, E70, E770); chimes (CH70). ""` SM Sync Modules are rated for 3.0 amperes at 24 VDC; DSM Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to installation instructions for SM (Wheelock #P83123) and DSM (Wheelock #P83177). FEATURES QUICK REFERENCE `For Weatherproof RSS Series Strobe (below) information, see Wheelock data sheet S9004. MODEL NUMBER MALL CEILING NON-SYNC SYNCS it STROBE 24 12 COLOR COLOR MOUNT MOUNT SM or DSM CANDELA VDC VDC RED MITE RSS- 24MCW -FR X X X 15/30/75/110 X X RSS - 24MCW -FW X X X 15/30/75 /110 X X RSS- 241575W -FR X X X 15 (75 on axis) X X RSS- 121575W -FR X X X 15 (75 on axis) X X RSSP - 24MCW -FR X X X 15 /30/75 / 110 X X RSSP- 241575W -FR X X X 15 (75 on axis) X X RSSP- 121575W -FR X X' X 15 (75 on axis) X X RSS- 2415C -FW X X X 15 X X RSS- 2430C -FW X X X 30 X X RSS - 2475C -FW X X X 75 X X RSS- 24100C -FW X X X 100 X X RSSWP- 2475W -FR` X X , X 75 @ -31°F X . X Page 2 of 4 — DN -5765 • 06/03/02 WIRING DIAGRAMS From To NEXT FIGURE 1: RSS /RSSP device. PRECEDING + + DEVICE DEVICE or FACP _ _ or EOLR From PRECEDING + + To NEXT From + - , f - - + To NEXT DEVICE, - �� - DEVICE PRECEDING _ __ _T4_ f f - - -- - STROBE or EOLR STROBE, f 1 SYNC MODULE, or EOLR SYNC MODULE, , I I or FACP I 3 or FACP KV 1 5765wr3 wmf 5765w1r1 wmf ly + — G + - STROBE AUDIBLE FIGURE 2: Strobe /plate assembly with audible FIGURE 3: Strobe /plate assembly with audible and visible operating in unison. and visible operating independently. From + + To NEXT PRECEDING _ DEVICE DEVICE, " or EOLR SYNC MODULE, or FACP 5785wi2,wmf CD STROBE AUDIBLE For details on using SM or DSM FIGURE 4: RSS /RSSP devices synchronized Sync Modules, refer to Wheelock with DSM Module; single Class "A" NAC circuit. data sheet #S3000, or Wheelock DSM _' installation instructions #P83123 SYNC + (for SM) or #P83177 (for DSM). SYNC- - FACP STROBE NAC i+ OUT 1 CIRCUIT OUT ® + IN 1 O • O (MINUS 1 O \ & CS) + AUDIBLE O - AUDIBLE FIGURE 6: RSS /RSSP devices C MINUS 2 synchronized with multiple DSM Modules. STROBE NAC 0 + IN 2 6 INTERCONNECTING WIRING SHOWN. N. 5765w" wmf CIRCUIT RETURN +OUT 2 MAXIMUM OF TWENTY (20) DSM MODULES. DSM #1 FIGURE 5: RSS /RSSP devices synchronized FACP STROBE ■ era with SM Module single Class "B" NAC circuit. NAC 0 SYNC + CIRCUIT — & SYNC - FACP SM STROBE ® + STROBE DSM #2 NAC CIRCUIT m - STROBE EOLR STROBE A .• CIO/ ICI CIRCUIT . SYNC - CIRCUIT - & SYNC + AUDIBLE DSM #3 EOLR ; STROBE a NAC @ SYNC + CIO/ - AUDIBLE e CIRCUIT — SYNC - u, 5765w,r8 wmf DN-5765 • 06/03/02 - Page 3 of 4 AWARNINGPV CONTACT WHEELOCK FOR CURRENT "INSTALLATION INSTRUCTIONS" (Wheelock #P8391.1, #P84022, and #P84025) AND "GENERAL INFORMATION" SHEET (Wheelock #P82350) ON THESE PRODUCTS. THESE MATERIALS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. • ADDING, REPLACING, OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO ENSURE THAT THE TOTAL AVERAGE CURRENT, AND THE TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • VOLTAGE APPLIED: THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE." • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • Note: USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF, AS THE STROBE MAY NOT FLASH. • Note Conductor Specifications: CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY.SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. - Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Adminis- tration (OSHA), local, state, county, province, district, federal, and other applicable building and fire standards, guidelines, regulations, laws, and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having junsdiction (AHJ). ARCHITECTS' AND ENGINEERS' SPECIFICATIONS The visual notification appliances shall be Wheelock RSS Series Strobe Appliances, or approved equivalents. The RSS Series shall meet and be Listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired) for Indoor Fire Protection Service. The strobes shall be Listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second minimum over the regulated voltage range and shall incorporate a Xenon flashtube enclosed in a rugged LEXAN® lens. All inputs shall be compatible with standard reverse - polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock RSS Series. The RSS Series Strobes shall be of low- current design and shall have zero inrush. Where wall- mounted multi - candela appliances are specified, the strobe intensity shall have a minimum of four (4) field- selectable settings and shall be rated per UL 1971 for 15, 30, 75, or 110 candela. The selector switch for selecting the candela shall be tamper- resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15- candela UL 1971 listing with 75 candela on -axis is required (e.g., ADA compliance). For ceiling -mount applications, the strobe intensity shall be 15, 30, 75, or 100 candela. When synchronization is required, the appliance shall be compatible with Wheelock's SM and DSM Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The visual appliances shall be designed for indoor surface or flush mounting. RSS Series Strobe Appliances shall Incorporate a patented Integral Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4" (10.16 cm) square, 100 mm European -type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trim Plate) shall be provided. An attaching cover plate shall be provided to give the appliance an attractive appearance. The appliance shall not have any mounting holes or screw heads visible when the installation is completed. The RSSP Series multi - candela or single - candela Strobe Plate shall mount to either a standard 4 -inch (10.16 cm) square backbox for flush mounting, or to the Wheelock SBL2 Backbox for surface mounting. All notification appliances shall be backward - compatible. Due to continuous development of products offered by NOTIFIER, specifications and product availability are subject to change without notice in accordance with NOTIFIER standard terms and conditions. Page 4 of 4 — DN -5765 • 06/03/02 October 19, 1998 DN -5566 • J -122 8 ® Wheelock N OT I F I E R AS Series Audible Strobe Devices F /RE SYSTEMS and AH Series Audible Devices Section: AudioNisual Devices GENERAL (15 ._ _ California 0 j State Fire Wheelock's new two-wire (patent pending) AS Series Audible 1l��,� Marshal Strobe Devices and AH Series Audible Devices feature less 7125 - 0785:131 current draw and reduced inrush. The audible provides a select- E 5946 CS 356 able choice of either a continuous horn tone or a temporal pattern (Code 3) tone when constant voltage from a Fire Alarm Control Panel (FACP) is applied. Each tone has three dBA settings to �� 41 choose from. All models (audible only or audible /strobe) may be 0B6A2.AY synchronized when used in conjunction with the SM or DSM 151 -92 -E (SM /DSM) Sync Module. Additionally, the audible may be silenced while maintaining strobe activation on combination AS Series units. AS Series Audible Strobes and AH Series Audibles are designed _ _ _ for maximum performance, reliability, and cost - effectiveness �" -_ while meeting or exceeding the latest requirements of NFPA 72 , ~._ - � ` J) -, ..- -•. (National Fire Alarm Code), ANSI 117.1 (American National Stan = '''77....,--- i I • ' - - : .• dard for Accessible and Usable Buildings and Facilities) and UL f - —•,•-_- .- , j; « ' Standard 1971 (Standard for Signaling Devices for the Hearing .wD - r '., Impaired) and UL 464 (Audible Signal Appliances). AS Series - �•- Audible Strobe Devices, when properly specified and installed in r r _ � accordance with NFPA/ANSI standards, can provide the Equiva +a . - --- lent Facilitation allowed under ADA Accessibility Guidelines r";.:`' (ADAAG General Section 2.2) by meeting or exceeding the -'4 --- illu mination which results from the ADA specified strobe intensity ' , ' k ' ' ° , of 75 candela at 50 feet (15.24 m). This is an illumination of 0.030 ' , ''' - lumens per square foot. 4, — z When used with Wheelock SM and /or DSM Sync Modules, syn- AS Audible Strobe AH Audible chronization of the continuous horn tone provides the temporal (Code 3) tone (mandated by NFPA -72 [1993] with an effective date of July 1996) simultaneously for all audible devices. This ensures a distinct temporal (Code 3) pattern when two or more . Patented Universal Mounting Plate allows mounting to single - audibles are within hearing distance. If not synchronized, the gang, double -gang, 4" (10.16 cm), or 100 mm European temporal could overlap and not be distinctive. At the same time, backboxes, orto the SHBB surface backbox. No additional trim the strobes will be synchronized. This provides the ability to plates are required. comply with ADA recommendations concerning photosensitive AS Series Audible Strobe Devices are available in wall - epilepsy and NFPA standards when installing two or more visual and ceiling -mount models: devices within the field of view. These features, and the ability to silence the audible devices, are achieved using only two Wall- mountmodelsareavailable 15,15/75, 30, 75, and 110 wires. candela intensities. The 15/75 candela wall- mounted strobes are listed at 15 candela under UL Standard 1971 and meet 75 FEATURES candela intensity on axis for ADA guidelines with low current • ADA/NFPA/ANSIcompliant. MeetsOSHA29Part1910.165. draw. • UL1971 listed for Signaling Devicesforthe Hearing Impaired and Ceiling -mount models are offered in 75 and 100 candela intensities. UL Standard 464 for Audible Signal Appliances. • Lower current draw and reduced inrush. • All models can be synchronized by adding the SM or DSM Sync Module to the NAC circuit: • Patented two -wire device. Sync the audible: Maintain the temporal pattern when two or • Selectable for continuous horn ortemporal (Code 3)tones. more devices are within an area. Meets NFPA requirement for • Field- selectable dBA levels for both tone varieties: Temporal Evacuation Notification. Continuous tone: anechoic at 90, 95, or99 dBA; reverberant Sync the strobe: Maintain true one -flash -per- second when at 82, 88, or 91 dBA. using two or more visual devices within the field of view. Meets Temporal (Code 3) tone: anechoic at 90, 95, or 99 dBA; ADA andNFPArequirements. reverberant at 75, 82, or 85 dBA. Silence the audible while maintaining the strobeflash, option. This document is not intended be used for installation purposes. try keep our '�O �oo� product information up-to-date up-to-dattand and accurate. We cannot We cannoo t coover r all all specific applications applications or anticipate all requirements. All specifications are subject to change without notue For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX (203) 484 -7118 c E R -- I F I E t■ rIJ N OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 BIGINEERINC 8 MANUFACTURING DN -5566 • 10/19/98 — Page 1 of 4 • • All features on two wires. • AS Series Strobe products are listed under UL 1971 for indoor • 12 -and 24 -volt models available. use with a temperaturerangeof32°F to 120 °F (0 °Cto49 °C) and • AH Series Audible Devices are available in two models: maximum humidityof 85%. • AH Series horns are listed under UL 464 for audible signal AH -12 orAH -24 Indoor Audible Horn is enclosed in a grille matching that of the AS Series Audible Strobes. appliances. • AH-12WP or AH-24WP (weatherproof) can be installed in- AH 12 WPandAH- 24WPaudibledevicesarelistedunderUL464 doors or outdoors. When used outdoors, they must be used with for indoor/outdoor use with a temperature range of -31°F to a WBB -R weatherproof backbox. 150 °F ( -35 °C to 66 °C) and maximum humidity of 95 %. GENERAL NOTES Q PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED • Strobes are designed to flash at 1 flash per second minimum INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, from 20 to 31 VDC (for24 VDC models), or 10.5 to 15.6 VDC (for SPECIFYING, OR APPLYING THIS PRODUCT. FAILURE TO 12VDCmodels). Note that NFPA-72 (1996)speafies a flash rate COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, of 1 to 2 flashes per second, and ADA guidelines specify a flash CAUTIONS, AND WARNINGS COULD RESULT IN IMPROPER rate of 1 to 3 flashes per second. APPLICATION, INSTALLATION AND /OR OPERATION OF THESE • All candela ratings represent minimum effective strobe intensity PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD based on UL 1971. RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. ORDERING INFORMATION MODEL NUMBER INPUT STROBE MOUNTING MODEL NUMBER INPUT STROBE MOUNTING VOLTAGE CANDELA OPTIONS* VOLTAGE CANDELA OPTIONS* AS- 2415W -FR 24 VDC 15 A, B, D, F, G, 0, R, X AS- 2475C -FW 24 VDC 75 A, B, ID, F, G, R, V, X AS- 241575W -FR 24 VDC 15/75 A, B, D, F, G, 0, R, X AS- 24100C -FW 24 VDC 100 A, B, D, F, G, R, V, X AS- 2430W -FR 24 VDC 30 A, B, D, F, G, O, R, X AH -12 -R 12 VDC - A, B, D, F, G, 0, R, X AS- 2475W -FR 24 VDC 75 A, B, D, F, G, 0, R, X AH -24 -R 24 VDC - A, B, ID, F, G, 0, R, X AS- 24110W -FR 24 VDC 110 A, B, ID, F, G, 0, R, X AH- 12WP -R 12 VDC - K AS- 1215W -FR 12 VDC 15 A, B, D, F, G, 0, R, X AH- 24WP -R 24 VDC - K AS- 121575W -FR 12 VDC 15/75 A, B, ID, F, G, 0, R, X SYNC MODULES'* INPUT VOLTAGE AVERAGE CURRENT MOUNTING OPTIONS* SM- 12/24 -R 12 VDC / 24 VDC 0.014 (12 VDC) / 0.025 (24 VDC) E, N DSM- 12/24 -R 12 VDC / 24 VDC 0.020 (12 VDC) / 0.038 (24 VDC) W NOTES: 1) COLORS: Wall -mount models offered in red; ceiling -mount models offered in white. 2) SUFFIXES USED ABOVE: W = Wall mounting; C = Ceiling mounting, WP = Weatherproofing; F = Fire lettenng; R at end = Red plate; W at end = White plate EXAMPLES: AS- 2415W -FR (Wall mounting - Fire lettering, Red plate), AS- 2475C -FW (Ceiling mounting - Fire lettering, White plate). For descriptions of MOUNTING OPTIONS, refer to NOTIFIER data sheet DN -6111, derived from Wheelock #S7000. SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Control Modules are rated for 3.0 amperes per circuit The maximum number of interconnected DSM modules is twenty (20). Refer to installation instructions for SM (Wheelock #P83123) and DSM (Wheelock #P83177). ■ AVERAGE CURRENT Average Current (Amperes)* at Low/Medium /High Audible Settings Voltage: 20 VDC 24 VDC 31 VDC 10.5 VDC 12 VDC 15.6 VDC Settings: LO MED HI LO MED HI LO MED HI LO MED HI LO MED HI LO MED HI 90 95 99 90 95 99 90 95 99 90 95 99 90 95 99 90 95 99 Model: dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA AS- 2415W -FR 0.070 0 074 0.088 0.064 0.072 0 087 0.058 0.067 0.090 - - - - - - - - - AS- 241575W -FR 0.084 0.089 0105 0.077 0.083 0.102 0.067 0.077 0.100 - - - - - - - - - AS- 2430W -FR 0 111 0.116 0.128 0.098 0.105 0.120 0.084 0.092 0.119 - - - - - - - - - AS- 2475W -FR 0.178 0.184 0.200 0.149 0.156 0.177 0.117 0.130 0.152 - - - - - - - - - AS- 24110W -FR 0.210 0.216 0.230 0.177 0.183 0.202 0.148 0.158 0.183 - - - - - - - - - AS- 1215W -FR - - - - - - - - - 0184 0.205 0.248 0.162 0.191 0.238 0.145 0.179 0.233 AS- 121575W -FR - - - - - - - - - 0.250 0.267 0 317 0.211 0.231 0.285 0.174 0.200 0.258 AS- 2475C -FW 0.279 0.287 0306 0.230 0.238 0.261 0.284 0.294 0.329 - - - - - - - - - AS- 24100C -FW 0.317 0.324 0.340 0.265 0.272 0.292 0.334 0.340 0.366 - - - - - - - - - AH -12 -R - - - - - - - - - 0.030 0.037 0.093 0.035 0 043 0.100 0.040 0.056 0.128 AH -24 -R 0.014 0.020 0.035 0.017 0.024 0.041 0.021 0 030 0.053 - - - - - - - - - AH- 12WP -R - - - - - - - - - 0.030 0.037 0.093 0.035 0 043 0.100 0.040 0.056 0.128 AH- 24WP -R 0.014 0.020 0.035 0.017 0.024 0.041 0 021 0.030 0.053 - - - - - - - - - °Average current per actual Wheelock Production Testing @ 10.5, 12, 15.6, 20, 24, and 31 VDC For rated average and peak current across the UL listed voltage range for both filtered and unfiltered VRMS, see installation instructions (Wheelock #P83509 [AS] and #P83519 [AH]). Page 2 of 4 - DN -5566 • 10/19/98 FEATURES QUICK REFERENCE WA MODEL NUMBER LL CEILING NON -SYNC SYNCS wl STROBE 24 VDC 12 VDC RED WHITE MOUNT MOUNT SM or DSM CANDELA AS- 2415W -FR X X X 15 X X AS- 241575W -FR X X X 15175 X X AS- 2430W -FR X X X 30 X X AS- 2475W -FR X X X 75 X X • AS- 24110W -FR X X X 110 X X AS- 1215W -FR X X X 15 X X AS- 121575W -FR X X X 15/75 X X AS- 2475C -FW X X X 75 X X AS- 24100C -FW X X X 100 X X AH -12 -R X X X X X X AH -24-R X X X X X X AH- 12WP -R X X X X X X AH- 24WP -R X X X X X X WIRING DIAGRAMS AS devices synchronized with SM Module single Class "B" (Style Y) circuit AS device non - synchronized. WITH audible silence feature. From + FACP ISM PRECEDING { _ } To NEXT © STROBE 9 + STROBE I DEVICE I - DEVICE NAC CIRCUIT or FACP or EOLR 0 9 — STROBE 1 EOLR' QS 0 9 OUT fl I l + - AS ;J m AH 15 SIGNAL Q - OUT J L Gr— —tc� AUDIBLE • EOLR VALUE AS and AH devices synchronized with AUDIBLE EOLR' DETERMINED DSM Module dual Class "A" (Style Z) _ NAC CIRCUIT BY FACP circuit with NO audible silence feature. 0 9"- AUDIBLE MAC CIRCUIT(S). DSM 0 SYNC+ AS and AH devices synchronized 0 sYNC— with multiple DSM Modules. FACP 6 + 1 INTERCONNECTING WIRING SHOWN. + IN 1 AS Q AS Q AH ;f 0 \ IN I MAXIMUM OF TWENTY (20) DSM MODULES. O-- 0 ` —O MINUS 1 it 9 + AUDIBLE NAC AUDIBLE � DSM #1 _ AUDIBLE FACP CIRCUIT. - AS - AS - AH NAC CIRCUIT STROBE OUT NAC 9 SYNC + CIRCUIT —10 SYNC - 0 9 - AUDIBLE MINUS 2 F AUDIBLE DSM #2 NAC 0 + IN 2 AS Q AS 10 CIRCUIT . — AS — AS AUDIBLE NAC + OUT 2 CIRCUIT RETURN _ J STROBE A , 0 SYNC + NOTES: CIRCUIT '- SYNC - • AS /AH must be set on continuous horn tone, and con- AUDIBLE nected to the SM or DSM Sync Module, to achieve NAC DSM #3 synchronized temporal (Code 3) tone CIRCUIT y - AS - AS - AH • For details on using SM or DSM Sync Modules, refer to Wheelock data sheet #S3000, or Wheelock installation STROBE A 9 SYNC + instructions #P83123 (for SM) or#P83177 (for DSM). NAC — 9 SYNC - CIRCUIT DN -5566 • 10/19/98 — Page 3 of 4 ■INARNING'!' CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS " - (W #P83509 [AS], #P83641 [AH -WP], and #P83519 [AH]) AND "GENERAL INFORMATION ".SHEET (Wheelock #P82380) ON THESE PRODUCTS. THESE MATERIALS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON NAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • VOLTAGE APPLIED: THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 100/110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • Note: USE AS/AH ON LY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE AS SERIES ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF, AS THE STROBE MAY NOT FLASH. • CONDUCTOR SPECIFICATIONS: CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with their installation instructions at the time of installation and at least twice'ayear or more often and in accordance with local, state, and federal codes, regulations, and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, distnct, federal, and other applicable building and fire standards, guidelines, regulations, laws, and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS' & ENGINEERS' SPECIFICATIONS • The notification appliances shall be Wheelock's patented AS Series Audible Strobe and AH Series Audible Horn devices, and when synchronization is required, companion SM and DSM Sync Modules, or approved equivalents AS Series devices and SM and DSM Sync Modules shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service) AH Series Audible Horn shall be listed under Standard 464 (Fire Protective Signaling). AS, AH, SM, and DSM devices shall be certified to meet FCC Part 15, Class B. • The devices shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3) tone when constant voltage from a Notification Appliance Circuit (NACS) of the Fire Alarm Control Panel (FACP) is applied; or synchronized temporal (Code 3) horn and synchronized strobe when used in conjunction with the SM or DSM Sync - Modules. • The AS Senes shall be designed so that the audible signal may be silenced while maintaining strobe activation (when used with the SM or DSM Sync Modules). The SM and DSM Sync Modules shall incorporate two inputs from Notification Appliance Circuits (NACS) for power connection from the Fire Alarm Control Panel (FACP). one for the strobe circuit (NAC), and one for the audible circuit (NAC). A single two -wire output shall control both the audible and visual appliances. Upon activation of the audible silence function of the FACP, the audible signal shall be silenced while maintaining strobe activation. • Sound output at 10 feet (3.048 m) shall be field- selectable for 90, 95, or 99 dBA anechoic for both continuous or temporal (Code 3) tone The AS Series shall provide listed strobe intensities of 15, 15/75, 30, 75, and 110 candela for wall -mount and /or 75 or 100 candela for ceiling-mount applications; with a -flash rate of one flash per second minimum across the listed voltage range. The strobe shall incorporate a Xenon® flashtube enclosed in a rugged LEXAN® lens. The maximum allowable current at 24 VDC shall be 87 mA @ 15 cd, 102 mA @ 15/75 cd, 120 mA @ 30 dd, 177 mA @ 75 cd, and 202 mA @ 110 cd. All devices shall incorporate a reduced inrush circuit design. • The strobe shall have a horizontal plane. • The Sync Module shall be designed and available in two versions: the SM- 12/24, for control of a single Class "B" NAC circuit; and a dual- output version, the DSM - 12/24, for control of either a single Class "A" or two Class "B" NAC circuits The DSM dual- circuit version shall provide the additional capability of "daisy- chaining," i.e., the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. DSM -12/24 interconnection capability shall be for a maximum of 20 modules (40 Class "B" NAC circuits or 20 Class "A" NAC circuits). Rated average current requirement for the SM -12/24 shall be 0 014 amperes @ 12 VDC and 0.025 amperes @ 24 VDC; the DSM -12/24 shall be 0.020 amperes @ 12 VDC and 0.038 amperes @ 24 VDC The SM Sync Module shall be capable of handling a three - ampere load at 12 or 24 VDC The DSM Sync Modules shall be capable of handling a load of three amperes per circuit in the Class "B" mode, and three amperes per module in the Class "A" mode at 12 or 24 VDC • SM or DSM Sync Modules and AS Audible Strobes shall be designed as a system for continuous activation of the strobes should the Sync Module contacts fail in the passive state (i.e., contacts remain closed). In this default mode, the strobes shall revert to a non - synchronized default flash rate • AS /AH Senes devices shall be designed for operation at 12 or 24 VDC, over their respective listed voltage ranges of 10.5 to 15.6 VDC, and 20 0 to 31.0 VDC The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for AS Series devices shall depend upon voltage and strobe intensity; current shall be as low as 0 058 amperes for 24 VDC versions and 0.145 amperes for 12 VDC versions. Rated average current for AH Series devices (volume set at high -dB output) shall be 0.041 amperes for 24 VDC versions and 0.113 amperes for 12 VDC versions. • All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of size #18 AWG (0.75 mm to #12 AWG (3.25 mm • AS /AH shall incorporate a patented Universal Mounting Plate which shall allow mounting to single -gang, double -gang, 4" (10.16 cm) square, 100 mm European backboxes or Wheelock's SHBB surface backbox. No additional' trim plate shall be required for flush mounting. • Dimensions for AS /AH appliances shall be 4.625" (11.7475 cm) square by 1.5" (3.81 cm) deep. Due to continuous development of products offered by NOTIFIER, specifications and product availability are subject to change without notice in accordance with NOTIFIER standard terms and conditions. Page 4 of 4 — DN -5566 • 10/19/98 June 5, 2001 DN -6821 • H -215 8 N �T 1 F 1 E R� FSD -751 P and FSD -751 RP Intelligent Photoelectric Duct Smoke Detectors with FlashScan® Section: Intelligent Addressable Devices GENERAL M EA 4t> An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system is thus '' ` (FSD -751P143 -00 -E ) . distributed to the entire building. Smoke detectors for use in air duct systems sense the presence of smoke in the duct. 389 -00 -E Approved The FSD 751 P air duct smoke detector is a photoelectric detector, LISTED (FSD (FSD -751 RP) combining this detection technology with an efficient housing S1115 FSD- 751RPA) MARYLAND design that samples air passing through the duct, allowing detec- State Fire Marshal Lion of a developing hazardous condition. When sufficient smoke __ California is sensed, an alarm signal is initiated at the fire control panel g State Fire Permit #2036 (FSD-751P) monitoring the detector, and appropriate action can be taken to Marshal Permit #2060 (FSD-751RP) shut off fans and blowers and change over air handling sys- �.'•., . 3240- 0028:205 terns, etc. This can isolate toxic smoke and fire gases or prevent their distribution throughout the areas served by the duct system. Two LEDs on each detector can be programmed by the system �` control panel to provide a local alarm indication. A remote alarm output is provided for use with auxiliary devices. The FSD -751 P ,at•� has remote test capability with the RTS451 /RTS451 KEY Remote Test Station. Bell cuv.wmf Traditional panels support addresses of 0 -99. The FlashScan® ,,' protocol supports addresses of 0 —159. Patented FlashScan® local visible indication. Remote LED annunciator capability is avail - is a new communication protocol developed by NOTIFIER Engi- able as an option. Each duct smoke detector can only be wired to neering that greatly enhances the speed of communication be- one remote accessory. tween analog intelligent devices. Intelligent devices communi- NOTIFIER panels offer different feature sets across different cate in a grouped fashion. If one of the devices within the group panel models. As a result, certain features of the FSD -751 P/ has new information, the panel stops the group poll and concen FSD -751 RP may be available on some control panels, but not on trates on single points. The net effect is response speed greater others. Possible features, if supported by the control panel are: than five times that of earlier designs. • Panel controls the LED operation on sensor. Operational modes APPLICATIONS are: RED blink, RED continuous, GREEN blink, GREEN continu- Duct smoke detectors have specific limitations. ous, and OFF. Duct smoke detectors are: SPECIFICATIONS • NOT a substitute for open area smoke detectors. FSD - 751 P • NOTa substitute for early warning detection. Operating voltage range: 15 to 32 VDC. • • NOT a replacement for a building's regular fire detection sys- Standby current: 300 pA @ 24 VDC (one communication every tern. 5 seconds with LED blink enabled). Call NOTIFIER for a copy of System Sensor's application guide, Operating temperature range: 32° to 131°F (0° to 55 °C). Proper Use of Smoke Detectors in Duct Applications, (A05- Humidity range: 10% to 93% (non - condensing). 1004 -00). Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 meters/ INSTALLATION min.). Wiring: For signal wiring (the wiring between detectors or Dimensions: 14.375" (365.125 mm) wide x 5.500" (13.970 mm) from detectors to auxiliary devices), it is recommended that single high x 2.750" (69.850 mm) deep. conductor wire be no smaller than 18 AWG (0.75 mm The duct Options: RTS -451, RTS 451 KEY, RA400Z. Separate auxiliary smoke detector terminals accommodate wire sizes up to 12 AWG power not required. (3.25 mm Flexible conduit is recommended for the last foot FSD - 751 RP (30.48 cm) of conduit; solid conduit connections may be used if Operating voltage range: 15 to 32 VDC (comm. line voltage) desired. and 24 VACNDC or 120/240 VAC auxiliary power* (separate Smoke detectors and alarm system control panels have specifi- source). 'NOTE: The FSD -751RP requires a separate auxil- cations for Signaling Line Circuit (SLC) wiring. Consult the con- Lary source. trol panel specifications for wiring requirements before wiring Standby current: 300 pA @ 24 VDC (one communication every the detector loop. The FSD -751 P /FSD -751 RP detector is de- 5 seconds with LED blink enabled). signed for ease of wiring; the housing provides a terminal stnp Auxiliary power current draw (@ 24 VDC): 26 mA (standby), with clamping plates. 87 mA (alarm). LED Features: If programmed with the system control Options: RTS -451, RTS -451 KEY, RA400Z, APA451. panel, two LEDs on each duct smoke detector light to provide FlashScan® is a registered trademark of NOTIFIER. This document is not intended to be used for installation purposes. We try to keep our ISO 9001 product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone (203) 484 -7161 FAX: (203) 484 - 7118 C E Ft I F I E 0 N OTIFIER" 12 Clintonville Road, Northford, Connecticut 06472 111611111111011 la MillEACIIAING DN -6821 • 06/05/01 — Page 1 of 2 Operating temperature range: 32° to 131 °F (0° to 55 °C). PRODUCT LINE INFORMATION Humidity range: 10% to 93% (non - condensing). Model Description Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 meters/ FSD -751 P Duct detector housing with FlashScan® photoelec- min) tric smoke detector. Dimensions: 14.375" (365.1 -25 mm) wide x 5.500" (13.970 mm) FSD -751 RP Duct detector with FlashScan® hotoeleo- high x 2.750" (69.850 mm) deep. 9 P Relay contact ratings: 2 Form -C, DPDT, 10 A @ 250 VAC, 10 A tric smoke detector, DPDT relay. @ 30 VDC (resistive). Minimum switching current of 100 mA @ ST -1. Metal sampling tube, duct widths 1' to 2' (see table 5VDC. at left for metric lengths). Programming specifications /requirements ST -3 Metal sampling tube, duct widths 2' to 4'. for intelligent system control panels: ST -5 Metal sampling tube, duct widths 4' to 8'. The number of devices that can have their LEDs programmed to ST -10 Metal sampling tube, duct widths 8' to 12'. illuminate is limited by the features of the panel and the individual RA400Z Remote annunciator alarm LED. devices. The.actual number of devices is determined by the control panel and its ability to supply LED current. Refer to the RTS451 Remote test station. Mounts in single -gang box. control panel installation manual for details. Includes red alarm LED and magnet test switch. INLET TUBE SELECTION RTS451KEY Key - activated remote test station. . 6821fn11181 F36 -09 -00 Replacement filters. Outside Duct Width Inlet Tube* MO2 -04 -00 Replacement test magnet. Up to 2 feet (0.6096 m) ST-1.5 S08 -39 -01 Replacement photo insect screen. P48 -55 -00 Replacement end cap for plastic sampling tube. 2 to 4 feet (0.6096 to 1.2192 m) ST -3 P48 -21 -00 Replacement end cap for metal sampling tube. 4 to 8 feet (1.2192 to 2.4384 m) ST -5 A5053FS Replacement photoelectric sensor board. 8 to 12 feet (2.4384 to 3.6576 m) ST -10 A5067 Replacement power board (without relay). *NOTE: Inlet tube is required and must be purchased separately. A5060 Replacement power board (with relay). Order one inlet tube for each duct smoke detector ordered. SAMPLE WIRING DIAGRAMS See product Installation Intructions A+' # � for wiring diagrams for the FSD-751RP. COMMUNICATION C.1 � M M _ LINE -- �- i MR 1st Detector 2nd Detector UL Listed in Loop in Loop e Control Panel ( 6 w1r1 .wm1 — The RA400Z z ■ FSD -751P Duct Smoke Detector r; • NJ 0 using a UL Listed control panel } o e _ C.1 ' 6821wir2 wmf I 1 ( , FSD- 751P ++ld RA400Z FSD-751P Duct i i i ;l T / • Smoke Detector I • I I with optional 1 ' / RA400Z 1 i s >- Y z The RTS451 NI � O V) fat Q U U 6821wn3 wan f A FSD-751P Duct ® _ K • Smoke Detector COMM I� r, COMMON TEST FSD - 751P [ wi thRTS451/ �" Detector � ' (4 1 ® . r-) R TS451KEY Terminals NMI Field- Installed NOTE: For RTS451, • JUMPER O� Terminal 3 is not used. O / !� (' 1 RTS451 does not have • U a Terminal 6. / LED RESET For RTS451KEY, Ter- 0 urinals 3 and 6 are not RTS451/RTS451KEY used. The RTS451KEY Page 2 of 2 — DN -6821 • 06/05/01