Loading...
Permit CITY OF TIGARD MASTER PERMIT PERMIT #: MST2000 -00029 qtlw DEVELOPMENT SERVICES DATE ISSUED: 02/14/2000 J `�" II 13125 SW Hall Blvd., Tigard, OR 97223 o SITE ADDRESS: 12125 SW SWEENEY PL PARCEL: 2S103AB -05600 SUBDIVISION: WALNUT GLEN - ZONING: R -4.5 BLOCK: LOT: 014 JURISDICTION: TIG REMARKS: PATH I: New detached single family dwelling w /attached garage & covered porch. BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 21 FIRST: 1,603 sf BASEMENT: sf LEFT: 15 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 342 sf GARAGE: 586 sf FRONT: 33 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 8 VALUE: 5 149,925.21 OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL: sf REAR: 30 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: RAIN DRAIN: 100 TRAPS: LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: 1 BOIUCMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1 GAS FURN > =100K: UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 4 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 • 600 amp: EA ADDL BR CIR: SIGNAUPANEL: IN PLANT: MANU HM/SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR > =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOWPAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPEARRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 5,574.18 This permit is subject to the regulations contained in the RIVERSIDE HOMES RIVERSIDE HOMES 15455 NW GREENBRIER PKWY 15455 NW GREENBRIER PKWY all other r applicable Code, State work k will Specialty Codes and STE 140 all other applicable laws. All work will be done in SUITE 140 accordance with approved plans. This permit will expire if STE BEAVERTON, OR 97006 BEAVERTON, OR 97006 -2115 work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LIC 70065 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Post/Beam Structural Plm/undslab Insp Electrical Rough In Gas Fireplace Electrical Final Footing Insp Post/Beam Mechanical PLM /Underfloor Framing Insp Insulation Insp Mechanical Final Foundation Insp Underfloor insulation Mechanical Insp Shear Wall Insp Rain drain Insp Plumb Final Slab Insp Crawl Drain /Backwater Plumb Top Out Exterior Sheathing Ins' Water Line Insp Final inspection Wtr Proofing Bsm't Wa Footin• - : undation Pr Electrical Service Gas Line Insp Appr /Sdwlk Insp Building Final Issued By : All ,...,‘,../ Permittee Signature : (1/1"(7 Call (503) •39 -4175 by 7:00 p.m. for an inspection needed the next busin s day V "'f•Y 01. TIGARD Residential Building Permit Application Plan Check# / - 5 ? 13125 SW HALL BLVD. New Construction Recd By Date Recd /', ( 1 - 0) TIGARD, OR 97223 Single Family Detached Date to P.E. V 503 - 639 -4171 Date to DST 2 •2 - 0 U F 503 - 684 -7297 ° Permit #0 -41trcs Print or Type Called Z' 7 - 2e�0 Lo\ I ncomplete or illegible applications will not be accepted 5Cv(z o - o CO/ 4 Name of Project Name Job GO COU,(I- (01 Mailing Address Address Site Address f-)(1 Architect s 1' 1 I 2 ) ? U \ "`° �(�� �, City /State Zip Phone Na---- `mo t, I ()erstd Idc>me5 Owner Mailing Address Name 6L/ j Yl u, Cirr nbrcr atdy rya Engineer Mailing Address ; �C ^ ity /State Z iR ()Al n /e p / 9 T"'ecwe aK �u'W �0`Y5-�1 !8& City /State Zip Phone General Name Contractor C(Jcit_t2_ (Lb 0(1 )197J2/ Describe work New 0 Addition 0 Alteration 0 Repair 0 Mailing Address to be done: Prior to permit Additional Description of Work: issuance, a copy City/te City/ Zip Phone of all licenses are required if Oregon Const. Cont. Board Exp. Date PROJECT , �07 A / expired in COT Lic.# 0 ..70(:)\(D G( J 1 1 / 7 4 VALUATION $ ``y database Mechanical Name NEW CONSTRUCTION ONLY: 92 % frc Sub- FQ a s Sq. Ft. House: 1vl `�t (n�l ' Sq. Ft. Garage if q A re s \ � 4p5S -' Prior to permit z j( (p l; 1109 Indicate the restricted energy installation by the electrical subcontractor in the following areas issuance, a copy C' /State - / e y of all licenses 0 iti " 75 . ! Phone I � Restricted i Audio /Stereo L / ar l� YM are required if Oregon Const. ont. Board Exp. Date Energy System Alarms expired in COT Lic.# r Installations Vacuum Irrigation database Lfu2S _ ]� System System Plumbing Name (check all that Other: Sub- north 5f Pre,nier T,unba.2 apply) Contractor Mailing Address Number of Units in Building Unit Number Designation I icp?)a6 I ()7th Has the Subdivision Plat recorded? N/A YES NO Prior to permit City /State Zip Phone issuance, a copy TI L e t q70 7 8 9 - 3677 of all licenses are Ore Const. Cont. Board Exp. Date required if Lic.# / 350 H 1 01 expired in COT database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with Name Oregon State laws. Electrical NcuLyr c. (_ -4- (C Sig ure of Owner /Agent Daz 19 9 Sub- Mailing Address / Contractor � 3 - 7 � E �y Contact P rs n Na a Phone # S -- - G�, ( ,pr f - 2 1 4 /3•3 i3 1 City/State Zip Phone Prior ua , a cop y Tort issuance, d ( R 97 x33 6 4 �0 - 0 UUU unce a copy FOR OFFICE USE ONLY: of all licenses are Oregon Const. Cont. Board Exp. Date Plat #: _ M /TL #' required if Lic.# expired in COT / c c 9 Cp ga 3/1 ,/0 1 /0Z - 43 5 lo " 05 database Electrical Lic. # �� n � Exp. Date Se asks: Z q, g W 5 (/ Electrical Supervisor Lic. # Exp. Date Enginring Approval: Planning Approval: TIF: Fo - Vm, /.971 / - XG O i:\dsts \forms\sfd- new.doc 11/20/98 3 -21 -2000 12:18PM FROM ACI MECHANICAL 503 639 0498 P.12 vs�ur�uu IVEI TR*v., 084 1211i Ltli ur ii�Axv �r uiviuia CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 -57's ' r'' JVED .'ORTANT PERMIT NOTICE MAR 2 2 2000 ACI MECHANICAL USA INC 12300 SW 69TH AVE TIGARD, OR 97223 Plumbing Signature Form Permit #: MST2000 -00029 Date Issued: 2114/00 Parcel: 25103A6•05600 Site Address: 12125 SW SWEENEY PL Subdivision: WALNUT GLEN Block: Lot 014 Jurisdiction: TIC Zoning: R4.5 Remarks: PATH I: New detached single family dwelling w /attached garage & covered porch. Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of the work to the address above, ATTN: Budding Dept lumbing inspections will be authorized until this completed form is received OWNER: PLUMBING CONTRACTOR: RIVERSIDE HOMES ACI MECHANICAL USA INC 15455 NW GREENBRIER PKWY 12300 SW 69TH AVE STE 140 T1GARD,.OR 97223 BEAVERTON, OR 97006 Phone #: Phone #: 598 Reg #: LIC 137663 D1.M 3-243PB AN INK SIGNATURE IS REQUIRED ON THIS FORM x a. .E'- Sig tune of Authorized Plumber If you have any questions, please call (503) 639 -4171, ext. # 310 O"` CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 RECED FEB 1 8 2000 IMPORTANT PERMIT NOTICE BY. HAUSER ELECTRIC 2375 SE 174TH PORTLAND, OR 97233 Electrical Signature Form Permit #: MST2000 -00029 Date Issued: 02/14/2000 Parcel: 2S103AB -05600 Site Address: 12125 SW SWEENEY PL Subdivision: WALNUT GLEN Block: Lot: 014 Jurisdiction: TIG Zoning: R-4.5 Remarks: PATH I: New detached single family dwelling w /attached garage & covered porch. Your company has been indicated as the electrical contractor for the permit indicated above. In order for the electrical permit to be valid, the signature of the supervising electrician is required. Please have the appropriate individual from your company sign below and return this Electrical Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No electrical inspections will be authorized until this completed form is received OWNER: ELECTRICAL CONTRACTOR: RIVERSIDE HOMES HAUSER ELECTRIC 15455 NW GREENBRIER PKWY 2375 SE 174TH STE 140 PORTLAND, OR 97233 BEAVERTON, OR 97006 Phone Phone #: 503- 762 -2126 Reg #. ELE 26 .950C LIC 122682 SUP 3833S AN INK SIGNATURE IS REQUIRED ON THIS FORM • X ‘ �aC Signature of Supervising Electrician • If you have any questions, please call (503) 639 -4171, ext. # 310 07/11/2000 Activities for Case #: MST20O0 -00029 3:24:29 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 04/28/2000 RB PART No Hold RB 04/28/2000 Report dtdt 4 -24 -00 (KS)- issues completed, except tempered glazing at master bathroom. ALSO; Unknown if post/beam inspections were completed- NO RECORD OF APPROVALS IN TIDEMARK. Protect main service line- metal plate protect. MSTA725 Framing Insp 05/02/2000 RB PART No Hold AKJ 05/02/2000 1) temp glazing req to be met by final 2) post/beam insp, no record of approval firestop all thru hole penetration: ok to drywall MSTA711 Post/Beam Mechanical 06/14/2000 RB PASS No Hold RB 06/14/2000 Support rectangular duct with metal strap. MSTA717 PLM /Underfloor 06/14/2000 RB PASS No Hold RB 06/14/2000 Plumbing appears to be adequately installed, except that water lines are concealed with insulation in floor space. Top -Out approved at earlier date. This inspection done at Final. MSTA710 Post/Beam Structural 06/14/2000 RB FAIL No Hold RB 06/14/2000 Post/Beam done at Final: Warned Contractor. 1. Add under -floor ventilation where lacking. 2. HD disconnected at frontal location. 3. Mechanical issue. MSTA799 Building Final 06/14/2000 RB FAIL No Hold RB 06/14/2000 1. Post/Beam Structural Issues. 2. Permanently cap rain drain. MSTA710 Post/Beam Structural No Hold RB 06/14/2000 MSTA798 Final inspection No Hold RB 06/14/2000 MSTA799 Building Final 06/16/2000 KBS PART No Hold AKJ 06/18/2000 provide landing and guardrail at ext man door providing access to crawl space MSTA799 Building Final 06/19/2000 RB PASS No Hold AKJ 06/19/2000 MSTA960 (F) Issue Cert. of Occupancy 06/19/2000 RB DONE No Hold JMT 07/11/2000 • Page 3 of 3 07/11/2000 Activities for Case #: MST2000 -00029 3:24:29 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA008 Permit Created 01/26/2000 GEO DONE No Hold GEO 01/26/2000 MSTA005 Application received 01/24/2000 GEO DONE No Hold GEO 01/26/2000 MSTA010 Check for prcl. restrict. 01/26/2000 GEO DONE No Hold GEO 01/26/2000 MSTA012 Plans routed to Plans Examiner 01/26/2000 GEO SENT No Hold GEO 01/26/2000 There are outstanding Plan Check fees due for MST1999 -00297 ($517.58). MSTA026 Plans approved by Pln Examiner 02/02/2000 BT2 DONE No Hold BT2 02/02/2000 MSTA030 Reviewed plans routed to DSTS 02/02/2000 BT2 DONE No Hold BT2 02/02/2000 MSTA700 Erosion 844 -8444 02/02/2000 02/02/2000 No Hold BT2 02/02/2000 MSTA705 Footing Insp 02/02/2000 02/02/2000 03/08/2000 KS PASS No Hold RB 03/09/2000 Ufer tagged. MSTA706 Foundation Insp 02/02/2000 02/02/2000 03/08/2000 KS PASS No Hold RB 03/09/2000 MSTA710 Post/Beam Structural 02/02/2000 02/02/2000 05/03/2000 KBS FAIL No Hold AKJ 05/03/2000 1) canc by request, app plans lost contractor will request insp to bring plans from office MSTA711 Post/Beam Mechanical 02/02/2000 02/02/2000 05/03/2000 KBS FAIL No Hold AKJ 05/03/2000 see struc p/b MSTA713 Crawl Drain /Backwater valve 02/02/2000 02/02/2000 03/10/2000 MRS PASS No Hold AKJ 03/12/2000 MSTA717 PLM /Underfloor 02/02/2000 02/02/2000 05/03/2000 MRS FAIL No Hold AKJ 05/03/2000 1) req stair to make insp 2) already insul MSTA720 Mechanical Insp 02/02/2000 02/02/2000 04/18/2000 KBS PASS No Hold AKJ 04/18/2000 soffit mech at gar MSTA722 Plumb Top Out 02/02/2000 02/02/2000 04/12/2000 MRS FAIL No Hold AKJ 04/12/2000 no test on waste MSTA723 Electrical Service 02/02/2000 02/02/2000 04/18/2000 CD PASS No Hold AKJ 04/18/2000 MSTA724 Electrical Rough In 02/02/2000 02/02/2000 04/18/2000 CD PASS No Hold AKJ 04/18/2000 MSTA725 Framing Insp 02/02/2000 02/02/2000 04/21/2000 KBS FAIL No Hold AKJ 04/24/2000 1) need plm top out app 2) toe nail shed rafters above gar door 3) plans indicate four 2x10 joist at gar also full bearing under 4) nail triple joist at gar 5) pos Conn glulam to post at gar 6) provide bearing under void at corner of gar stem wall 7) provide full bearing under double joist at bonus room 8) glazing above tub needs teml 9) provide attic access at each level 10) add header at range vent 11) complete sway bracing at roof truss 12) gas test ok Page 1 of 3 07/11/2000 Activities for Case #: MST2000 -00029 3:24:29 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA726 Shear Wall Insp 02/02/2000 02/02/2000 04/04/2000 KBS FAIL No Hold AKJ 04/04/2000 incomplete MSTA727 Exterior Sheathing Insp No Hold BT2 02/02/2000 MSTA735 Gas Line Insp 02/02/2000 02/02/2000 04/12/2000 MRS PASS No Hold AKJ 04/12/2000 no tags with me, will tag later MSTA740 Insulation lnsp 02/02/2000 02/02/2000 05/02/2000 RB PART No Hold AKJ 05/02/2000 see framing 5/2 MSTA752 Rain drain lnsp 02/02/2000 02/02/2000 03/10/2000 MRS PASS No Hold AKJ 03/12/2000 MSTA760 Water Line Insp 02/02/2000 02/02/2000 03/10/2000 MRS PASS No Hold AKJ 03/12/2000 MSTA765 Appr /Sdwlk Insp 02/02/2000 02/02/2000 No Hold RB 06/14/2000 Private Drive. MSTA790 Electrical Final 02/02/2000 02/02/2000 06/05/2000 CD DONE No Hold CD 06/05/2000 MSTA795 Mechanical Final 02/02/2000 02/02/2000 06/05/2000 MRS PASS No Hold AKJ 06/05/2000 MSTA797 Plumb Final 02/02/2000 02/02/2000 06/05/2000 MRS PASS No Hold AKJ 06/05/2000 MSTA799 Building Final 02/02/2000 02/02/2000 06/05/2000 KBS FAIL No Hold AKJ 06/05/2000 1) post street address at front of structure 2) final erosion control app 3) temp glazing req above tub 4) provide access to crawl 5) seal overdriven nails at ext MSTA032 DST Post- Review Completed 02/07/2000 BON DONE No Hold BON 02/07/2000 MSTA080 (F) Ready to issue 02/07/2000 BON DONE No Hold BON 02/07/2000 Be sure to collect fees from previous plan review and pay outstanding fees in Tidemark. (MST1999- 00297) MSTA092 (F) Issue combination permit 02/14/2000 GEO DONE No Hold GEO 02/14/2000 MSTA095 Issue plumbing signature form 02/14/2000 GEO DONE No Hold GEO 02/14/2000 MSTA097 Issue electric signature form 02/18/2000 SLT RECD No Hold ST 02/18/2000 MSTA095 Issue plumbing signature form 03/22/2000 SLT RECD No Hold ST 03/22/2000 Change of plumbing contractor. MSTA726 Shear Wall lnsp 04/07/2000 TLP PASS No Hold AKJ 04/09/2000 MSTA722 Plumb Top Out 04/14/2000 MRS FAIL No Hold MRS 04/14/2000 house locked MSTA722 Plumb Top Out 04/14/2000 MRS PASS No Hold AKJ 04/16/2000 MSTA735 Gas Line Insp 04/18/2000 KBS FAIL No Hold AKJ 04/18/2000 extend gas piping to both fireplaces sleeve tubing at fireplace MSTA735 Gas Line Insp 04/21/2000 KBS PASS No Hold AKJ 04/24/2000 MSTA725 Framing Insp 04/24/2000 KBS FAIL No Hold AKJ 04/24/2000 corr not made Page 2 of 3 CITY OF TIGARD BUILDING INSPECTION DIVISION M T 1Z400 - WO 74 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 /+ 'Z) BUP Date Requested ( 4 0) AM K PM BLD Location 7//7C S Suite MEC Contact Person Ph �t ���� tiy3 039 PLM Contractor Ph SWR ILDI Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler • Fire Alarm Susp'd Ceiling / Roof Misc: I • 'ASS PART FAIL • ' BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final✓ PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final -" PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final N./ PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ I Unable to inspect - no access ADA W A pp r oach /Sidewalk .. Date VO Inspector Ex PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION (5 4.454 2600 e./ 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 d BUP rr Date Requested (P / L DD AM PM BLD Location 12,1 ZS 3 ' / A Suite MEC Contact Person r I i Ph % / - 39 ? y PLM Contractor Ph SWR 1 BUILDINP Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: ae SIT • • • st & Bea Ext each /Shear V G2; .r.1/4)(,e Int Sheath /Shear Framing Insulation (� 1�-.� Drywall Nailing ] , 'i-� d ?Os_k___ ■_.--- Fire wall i n SC. �� C ) K.\ C) q,C-c c"._.--g e• Fire Sprinkler V V � � � � Fire Alarm C ,&• • Roof Susp'd Ceil�g • `g 4+ - 1,4./IA t � c .k, Crres( U C Q.-./ Misc: 411111 Ir �5 PART FA I IL-41- `� (-(-42- \ ' '^ `-- ---\-- 4 I_LUMBIN `� ��_ J 6—,5l, .I-ost & Beal. J� Under Slab L,L.AJ ,--.)_ sr". . Top Out 1 _D .��/� 0 T Water Service If �✓-- C` Sanitary Sewer - _ . / Rain Drains _ • A A _ _ 1. 1 Fi. - • S PAS PART FAIL C IA,. 6 f • .„ ._► / ••st & Beal, - , , ra_L ' v" Gas Rough Lin ki \ I • I C Gas Line W Smoke Dampers V) V21,�..�,v, J ti^ \ �.� 1 Sc Fi g - / J PASS PAR FAIL , OP _ _ _ _ . i EL CTRI • L - t� o� f C- C _ SZ_O -K, Service � .A j� 1 ., A.. UG /S ab �A.5 tt� l--y�' v/./N �` 0)---r 5 n et. C.2, . Rough In Low Voltage Fire Alarm 2 I OP _a ' ∎ . - _ ` aN` Final./ N ` c G . PASS PART FAIL Backfill /Grading Sanitary Sewer ,..ti Storm Drain V \ [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin 6\ r �� Fire Supply Line V ` [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA 7 ) • .roach i s - Date 1 4/ D Inspector Ext f E__ PART FAIL DO NOT REMOVE this inspection record from the job site. 7 CITY OF TIGARD BUILDING INSPECTION DIVISION Msr 7 w - 00024 24 -Hour Inspection Line: 639 -4175 Business Lin : 639 -4171 BUP Date Requested C0/5 /00 AM PM BLD Location ) i 1 Z S �1.P� ��1 .`�l� Suite MEC ����� Contact Person f Ph '1L./ 3 ,31 3 g PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS T FAIL MBI Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Fi FAIL CHANICAL Rough In Gas Line g S m Dampers inal PART FAIL C TRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ I Unable to inspect - no access ADA Ophe l / 0-- oach /Sidewalk Date o Inspector 12 /� Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST Z�C 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested G9/5 /oD AM PM k BLD Location 1 5 ■ Suite MEC Contact Person 10.0i÷ Ph a - 3 1 2 PLM Contractor Ph SWR fuILDIN) Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain �� /,� SGN Slab Crawl Drain Inspection Notes: n r����� f J 3 �� S IT Post & Beam Ext Sheath/Shear 3 tr ay n �/ Jn r'nse Int Sheath /Shear ' Framing i:ST 5T Ab @ r= Nr act ST"?2, Insulation Drywall Nailing ) 1~ I (.l.a4L E a7 A-1rrzoL. CA r' Firewall 9 Fire Sprinkler C.) T2Ji i PE7L6� �a L 4Zi.'S' -, : . 4'u ��. 4 Fire Alarm Susp'd Ceiling �o v c J.. ACCT S S ( a644/1._. Roof S'6xyL V vcs":".o P AS S PART PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line - Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA / Approach /Sidewalk Date Z — Inspe . Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 1-00O ' 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested U S (f.) AM \ PM BLD Location /7_/ 2iS < Suite MEC Contact Person A ° .1" Ph 1-/(1--353g PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection No Slab SIT Post & Beam ) _ �� �,�(/ Ext Sheath /Shear ___ Int Sheath /Shear _ Framing Insulation Drywall Nailing Firewall Fire Sprinkler _ Fire Alarm Susp'd Ceiling Roof Misc: Final • PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL tLECTRICAI� Service Rough In UG /Slab Low Voltage Fire A PART FAIL i : ackfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA g Approach /Sidewalk Other Date ■/ Inspector Ext Final PASS PART FAIL B • N • T REMOVE this inspection record from the job site. ■ CITY OF TIGARD BUILDING INSPECTION DIVISION MST 70:C7 - C2iq 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested S 31(70 AM PM BLD Location 2-1 2 S 3 / Suite MEC Contact Person aarAt Ph yy 3-393g PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler �� _ Fire Alarm fare Susp'd Ceiling Roof Misc: Final '4 PASS PART FAIL - ost & Beam Under ab ` L /WO Top Out Water Service Sanitary Sewer Rain Drains Final !� PASS PAR 0j MECHANIC : / Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Date 1 Inspector Final PASS PART FAIL D • N • REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST (V 03v 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested s 3/t AM PM BLD Location I ZI 7iS Suite G MEC Contact Person LLD Ph yu ?' 3 ; PLM Contractor Ph SWR UG Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT ea Ext a tFia 7Shear Int Sheath /Shear �1 �9 Framing i. [' /1 A, ecE c r - �_. +y '7� �Qlv�ST. ( f 9 ,;/ 1 - 7 201, J Insulation Drywall Nailing (1MPZ¢crv/LI oti' c c. - f pvm C'i�.o spLc,r - D/L) Firewall Fire Sprinkler 1 ti ( el ,c;<<•S Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART � EAIL � PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL • HAN & Bearli ) - .1• " rn Gas Line Smoke Dampers Final 6yr: PASS PART ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Z-- O o Other Date S Inspecto Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 7o- OcX Zef 24 -Hour Inspection Line: 639 -4175 Business Line: 639 71 BUP Date Requested 5 / 2 /00 AM Q/ PM BLD Location 1 2l Z S S Suite MEC Contact Person a� Ph PLM Contractor Ph SWR trUILDItV Tenant/Owner ELC Retaining Wall ELR Footing Access: W4S FPS Foundation _ ` _ `�'"r, OO 4 1 Ftg Drain f ? ^� �/ SGN Crawl Drain Inspection Notes: ! \ex s e wl Slab SIT Post & Beam Ext Sheath /Shear Int Sheath/Shear --6 _ a l,ll • V `Q9 ' A Drywall Nailing Fire wall ( 1 A °C.)/ l/�/�S Fire Alarm N l� Fire Sprinkler [ — ` ^ ^S Susp'd Ceiling �Y Roof Misc: Final PASS FAIL PLUMBING r va Post & Beam Under Slab Top Out WQ S ' "-1 � T'W �1/�C�� �•U Water Service v Sanitary Sewer Rain Drains 9- , -r.�S _ Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL 0 CA Service �/ sT2—.3/1/4r Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading • Sanitary Sewer - Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA ,t ‘re; �� O t he oach /S Date 7 V Inspector Exti / c3 Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION ST 2- 0007/7 24 - Hour Inspection Line: 639 -4175 Business Line: 639 - 4171 BUP rr,, ( Date Requested vl�T an AM I 13 7 PM BLD Location I LI i c C 11 Suite MEC Contact Person 12.00t991- Ph 1 W3 19 Z ? PLM Contractor Ph SWR Bp1LDI$ Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear G\I /� Int Sheath /Shear V% S lI 2 0 , t-4.-v‘ Nra- '6 , Insulation '� Q n C i Drywall Nailing l�(,�1� �c erk- �. Firewall , (-� V ' A* r V- \ ` Fire Sprinkler Vt��,� r �J Fire Alarm Susp'd Ceiling ` CIO G S ' � � ° ()_-( -- k �`-"" C Q Roof e \ ��Ill� UU Q1-./ Misc: 7 - A Final • PASS 'j FAIL • � — � -et I �- : L� PLUMBI ', l� C../ 0 -4' I i ,� 0 6 ' • kA- L ` S e cc c_._k_ Post e r S l Beam ab " U 1 _ _ tea, \ Under l' e 1 C i f ( Top Out I Water Service Sanitary Sewer Ai n�� {.f 1Uj -016 5S • Rain Drains Final PASS PART FAIL MECHANICAL l t A �_ r L A .. Post & Beam �` Rough In A , ∎L t ' _ ' - _ ` _- Gas Line Smoke Dampers /, T V ^ F ■ PASS PART FAI �YZ eQ' L.r L ) 3.***Ia._ ` �f � /v `� C S t. s S l/�_S ELECTRICAL S ervice CXY tx .9 Rough In UG /Slab 1 � ✓ _ �. ck A\ s v ti , Low Voltage p ,, Fire Alarm WI/.14/VL.(/lIV 0 cj.ex".A./. Final 1.1 S �� C PASS PART FAIL r 1v A-- 0 c /NZQ- a Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Z Q Q v CA Other Date I Inspector Ext 3 1 5 Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. . _ CITY OF TIGARD BUILDING INSPECTION DIVISION MST o' ' ' - 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 ,�J BUP " .2v 7 / Date Requested Q 71 `' 2 C.) AM PM PC BLD Location 42 /? (C) 9za -de-t-c / Suite MEC Contact Person Ph V V3 '3 13 PLM Contractor Ph SWR UILDIItG) Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART 1.1-L-) PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: / [ ] Unable to inspect - no access ADA � A , Approach /Sidewalk Date ( j 2 dU Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr 20i0 Q'b24 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 6 1724/0 0 AM PM BLD Location 7_125 5 LA J Suite MEC Contact Person Ph c / PLM Contractor Ph SWR UIB LDIN� Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear "Al ,vii ' PivA.i!h d,a c' Too /evr Insulation Drywall Nailing -46" l0i4 SA 5 �Jvo2 Firewall Fire Sprinkler 'A/yip-ors" ,.,i; , - � A.Z i LG Fire Alarm Susp'd Ceiling 660/Lpv ,az c Jens, ( 5.42,4 Roof J Misc: � - 77os.r vz' Ow iE Grla -' ('lv�.l asp fo 7a'sr @ C7 detire,aScr. Final PASS PART e...—FAIL 7f7t9 � ��0 /J7( G , < S PLUMBING Post & Beam e 42ov �.: .��[- �F}►ry, c�,�c��� �,u�� JrocSr .© U 7� Under Slab 4 Zj &j ' 4Ic»- ��.� ,v �r ���,••e,��L,� {�� Top Out Water Service ( vs / /1 c<.S -cc 4 ZFN../E Sanitary Sewer Rain Drains id /Lnv 11 /7 Final PASS RT FAIL -JP li i- - CHANT b rrosf8 bearrr - QA c 9r e- 5T = �?O P. S%L -'�'•� �D !yli.�iv s Rough In C ,r if 7 as Li mo e D 3mpers Final AS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date ./-49 2y Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST WOD —O& 2 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested Li "/oo AM PM X/ BLD Location / 2-1 Svv Suite MEC furl Contact Person Ph 7 (D 77 Z'/ PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing L ■ 1 - • _ .AIL Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAN tic UG /Slab Low Voltage Fire Alarm Final PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Other q�-� Date V /r U V Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2 -Old ac? 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / �/ BUP Date Requested L f/ i g /00 AM PM BLD Location 12 - 2-S � S SI/� et //( / Suite MEC Contact Person i Ph y t 3 PLM Contractor • Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing ,S6 7 01 Insulation Drywall Nailing gelS ,Z,-', S TU Firewall Fire Sprinkler SEEv. s Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL ANICrAt7 os - ou•h • as Line k SmoRTD:m•-rs Fi - PAS' PART 4r E CTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Date / ���� Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST WOO OM Z) 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 1 OD AM PM BLD Location 17.1 2_S .S Suite �j MEC Contact Person I�•.�'�P, PI/'7 3 ��7 ? PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler --- l L Fire Alarm OP' Susp'd Ceiling Roof Misc: Final PASS PART FAIL i l _ _ � COMBIIIG - r Post Beam Under Slab op • 'a er Service Sanitary Sewer Rain Drains Final PASS PART F L MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Date 1 1,, j 3 Inspector Ext : J Final PASS PART FAIL DO N T REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST c. 1- 4 -71)_ U7ra 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP Date Requested 4// AM_ PM BLD Location 0 d' t.J Rite} Suite MEC Contact Person a fp l 1 Ph (N 3 / 3 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam U •= - b op 0 Wa er Service Sanitary Sewer Rain Drains Final C . & PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line • ADA ( l Approach /Sidewalk Date t , � i ! . Inspector 2 /17/ d '-- Ext Other Final PASS PART FAIL DO N T REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST - zoo Dim zif 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 I, BUP Date Requested 11 171 AM PM BLD Location [ 2- 1 2-S S Suite q MEC Contact Person Ph y Li 3 - 3/ 3 / PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling / /a _ / ` . /gig Roof Misc: Final PASS__ PART FAIL c MBINT, ` ti Post & Beam Water Service Sanitary Sewer Rain Drains Final .� l PASS P: - T F • f / _ • �/f/7� .,113__■■(ri� ��� / Post & Beam Gas Line ;e Smoke Dampers Fina S PART FAIL RICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA ��'/� /J !7 Approach /Sidewalk Date 1 1/12-/ (6 Inspector 1 /' I Ext 5 � Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION C OA'' _ 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST Q0,5 29 BUP Date Requested" _ f 7 OD AM PM BLD Location 1 2 ! S 1AA° ,, Suite MEC Contact Person 12,6 bait" Ph t 'I 1 /3'293q PLM Contractor Ph SWR UILDING" Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear eat Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: F' • tap) PART FAIL ING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA L ' //7 /0d !l Otheoach /Sidewalk Date I nspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION 4ap Zero -000a9 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 I BUP / Date Requested / oo AM PM BLD Location Z I Z S S L Suite MEC Contact Person p,Q� ilit Ph Y1-13-3139 PLM Contractor Ph SWR UILDIN C1 Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear ra " /-teCb' �,o Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date — * Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2 COp - 60039 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 VO0 1 / BUP Date Requested 2 AM �c PM BLD Location 12 S Suite u MEC Contact Person 0.012,L____ Ph y ! 3 -313? PLM Contractor Ph SWR ILDIy� Tenant/Owner ELC Retaining Wall ELR oo in Access: oundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing &j - — 74 Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final ART FAIL MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading • Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date 1— 47e Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Z.000_Cr10-2g 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 3/l 0 00 AM PM BLD Location J 2 i 2 S 5 ^^ pi. Suite MEC �� Contact Person 1) A. Ph Li t/ i 2 3 ! PLM Contractor Ph SWR ),ppb - 1 BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg D 442 Inspection Notes: SGN a. SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Fin PART FAIL MBIN Post & Beam Under Slab Top Out er Sew' Fi ASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Date �v � Inspector 1 Ext Other Final PASS PART FAIL 0 NOT REMOVE this inspection record from the job site.