Loading...
Permit I CITY OF TIGARD l , r ,,, # ,,. i ;, DEVELOPMENT SERVICES ELECTRICAL PERMIT ' 1! 13125 SW HaII Blvd., Tigard, OR 97223 (503) 639.4171 PERMIT #: ELC96 -0676 DATE ISSUED: 10/23/96 PARCEL: 25112DA -00700 SITE ADDRESS...: 15333 SW SEQUOIA PKWY SUBDIVISION • EXPIRED ZONING:I -P BLOCK • LOT • Project Description: ADD BRANCH CIRCUITS - -- RESIDENTIAL UNIT - - -- -- -TEMP SRVC /FEEDERS - - -- MISCELLANEOUS 1000 SF OR LESS • 0 0 - 200 amp • 0 PUMP /IRRIGATION • 0 EACH ADD'L 500SF...: 0 201 - 400 amp • 0 SIGN /OUT LINE LTG..: 0 LIMITED ENERGY • 0 401 - 600 amp • 0 SIGNAL /PANEL • 0 MANF. HM/ SVC /FDR..: 0 601+amps -1000 volts.: 0 MINOR LABEL (10)...: 0 - - -- SERVICE /FEEDER - - -- - - -- BRANCH CIRCUITS -- -ADD'L INSPECTIONS-- - 0 - 200 amp • 0 W /SERVICE OR FEEDER: 0 PER INSPECTION • 0 201 - 400 amp • 0 1st W/O SRVC OR FDR.: 1 PER HOUR • 0 401 - 600 amp • 0 EA ADD'L BRNCH CIRC: 11 IN PLANT • 0 601 - 1000 amp • 0 PLAN REVIEW SECTION 1000+ amp /volt • 0 > =4 RES UNITS • > 600 VOLT NOMINAL..: Reconnect only • 0 SVC /FDR >= 225 AMPS..: CLASS AREA /SPEC OCC.: Owner: FEES PACIFIC REALTY ASSOCIATES type amount by date recpt 15333 SW SEQUOIA PKWY PRMT $ 90.00 TAT 10/23/96 96- 285552 SPCT $ 4.50 TAT 10/23/96 96- 285552 TIGARD OR 97224 Phone #: Contractor: STONER ELECTRIC $ 94.50 TOTAL 2701 SE 14TH REQUIRED INSPECTIONS PORTLAND OR 97224 Phone #: 503 -233 -3631 • Reg #..: 000448 This permit is issued subject to the regulations contained in the ,-� i iUlt -o( Tigard Municipal Code, State of Ore. Specialty Codes and all other Permit Signature applicable laws. All work will be done in accordance with Ai 7 approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more a A . _ /.. • 4 l.ii[_..,_. than 180 days. I s - l e d By OWNER INSTALLATION ONLY - - -- / The installation is being made on property I own which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: CONTRACTOR INSTALLATION ONLY---- - SIGNATURE OF SUPR. ELEC' N : DATE: LICENSE NO: Call for inspection - 639 -4175 ` Community Development ELECTRICAL PERMIT APPLICATION 13125 SW Hall Blvd. - r �► /_ Tigard, OR 97223 Permit # C wq6 -6107!6 ,�drm r � Date Issued /U/ .3/9� 1 � ��1 Phone (503) 639 -4171 ""'" FAX (503) 684 -7297 CITY OF TIGARD TDD No. (503) 684 -2772 Inspection (503) 639 -4175 1. Job Address: �� 4. Complete Fee Schedule Below: Name of Development c..�: a� n< _. Number of Inspections per permit allowed Address 153 4 `- e_cbv o i0.- '\4 y Service included: Items Cost(ea) Sum City /State /Zip ---- i � �, s-r� C S C\1 aay 4a. Residential - per unit 1000 sq. ft. or less $110.00 4 Name (or name of business) Each additional 500 sq. ft. or $2s.00 portion thereof 1 Commercial RI Residential El Limited Energy $25.00 Each Manuf'd Home or Modular Dwelling Service or Feeder $68.00 2 2a. Contractor installation only: 4b. Services or Feeders Installation, alteration, or relocation Electrical Contractor 4 y\-o( TrA. `��_c-mac.- 200 amps or less $60.00 2 Address ( 10\ d� V--\"`" 201 amps to 400 amps $80.00 2 City Pp T u�nsck State Zip Q , of 2 401 amps to 600 amps $120.00 2 ty p 1 $1 80.00 2 601 amps to 1000 amps Phone No. R.33'" 33c, I Over 1000 amps or volts $340.00 2 Job NO. (9 9q :39115 Reconnect only $50.00 2 contractor's license NO. c:24--/RR 4c. Temporary Services or Feeders Contractor's Board Reg. No. Xiii S o2 3 Installation, alteration, or relocation Signature of Supr. Elec'n �/_ ..� , _ 2 De) re 200 amps or less 2 02 License No. 4 /002S S 1 one No. c: 3 3 -36 3 I 201 amps to 400 amps $50.00 2 401 amps to 600 amps $75.00 Over 600 amps to 1000 volts $100.00 . 2b. For owner installations: see „b„ above. 4d. Branch Circuits Print Owner's Name New, alteration or extension per pane Address a) The fee for branch circuits with purchase of service or feeder fee. 2 City State Zip Each branch circuit $5.00 Phone No. b) The fee for branch circuits withou The installation is being made on property I own which is purchase of service or feeder fee. �,p 2 not intended for sale, lease or rent. First branch circuit I $35.00 ?, Each additional branch circuit I \ $5.00 1s e 0 Owner's Signature 4e. Miscellaneous (Service or feeder not included) 2 3. Plan Review section (if required): Each pump or irrigation circle $40.00 2 Each sign or outline lighting $40.00 Signal circuit(s) or a limited energy 2 Please check appropriate item and enter fee in section 5B. panel, alteration or extension $40.00 - 4 or more residential units in one structure Minor Labels (10) $100.00 Service and feeder 225 amps or more System over 600 volts nominal 4f. Each additional inspection over Classified area or structure containing special occupancy the allowable in any of the above as described in N.E.C. Chapter 5 Per inspection $35.00 Per hour $55.00 In Plant $55.00 Submit 2 sets of plans with application where any of the above apply. Not required for temporary construction services. 5. Fees: o 5a. Enter total of above fees $ 60. NOTICE 5% Surcharge (.05 X total fees) $ i4.5'0 PERMITS BECOME VOID IF WORK OR CONSTRUCTION Subtotal $ 4. 5b. Enter 25° /r, of line A for AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR Plan Review if required (Sec.3) $ A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS Subtotal $ y.s COMMENCED. wordkomdMelec. ❑ Trust Account # -- $ prm•epp Balance Due $ • May 3, 1999 CITY OF TIGA Stoner Electric O REGON FILE 2701 SE 14th Copy Portland, OR 97202 Re: Permit ELC96-0676 for work at 15333 SW Sequoia Tigard, OR To Whom It May Concern: It has come to our attention that the work permitted by ELC96 -0676 has not been inspected as required by OAR 918- 271 -0010. OAR 918 - 271 -0010 is reproduced below for your convenience. OAR 918 - 271 -0010 Calls for Inspection (1) All persons who take out an electrical permit, homeowners as well as electrical contractors, shall request an inspection within 24 hours of: (a) The completion of any electrical installation intended to be covered or concealed or which is intended to be placed into service before the final electrical inspection; and (b) The completion of all electrical installations for the job site covered by a particular permit. (2) Transactions under a master inspection permit are covered by separate requirements. The penalty for failure to request a timely electrical inspection is found in this excerpt from OAR 918 -307- 0000 shown below: 3) Civil penalty amounts. A "subsequent violation" is a repeat violation of any electrical statute or rule within a 36- month period of any order for the same violation. (a) A penalty of no less than $250 for the first violation and $500 for subsequent violations shall be charged for violations of (A) OAR 918- 271 -0010 for failure to request a timely electrical inspection; or (B) Electrical Safety Law or rule, including code, not expressly mentioned in this rule. Please arrange for an inspection of the electrical installation covered under permit ELC96 -0676 within 30 days. You can request an inspection by calling our 24 -hour inspection line at (503) 639 -4175. In order for the inspector to inspect electrical installations at an occupied structure a responsible adult must be on -site to provide access. If necessary for the inspection a ladder must be provide on site. If you have any questions feel free to call me at (503) 639 -4171 ext. 356. Sincerely, Chuck Dutton Senior Electrical Inspector • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested AM PM BLD Location 153 3 ; Ce.q /J.nl‘& , P tutj MEC Contact Person PLM Contractor Sit AfteA, Ph 2-33 -3(031 SWR BUILDING Tenant/Owner SA-1 ELC Q69 (n 7c., Retaining Wall ELR Footing • ` Foundation FPS Ftg Drain ' NOT REQUESTED Crawl Drain I FOUND DURING RESEARCH SGN Slab NO INSPECTION(S) FOUND IN FILE SIT Post & Beam Ext Sheath /Shear I (' Int Sheath /Shear Framing Insulation Drywall Nailing Firewall — Fire Sprinkler � `�1< - _ _6. j Fire Alarm Susp'd Ceiling -e— Roof Misc: Final ems/ 1 PASS PART FAIL 7.- PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer EXPIRE Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL LECTRICAtT Service Rough In UG /Slab Low Voltage Fire larm in PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date y 7 -.0a Inspector .Gh iC / Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.