Loading...
Plans /ap._sa tqco I Fire & Building Products CENTRAL Customer Service/Sales: Technical Services: Tpl: (800) 381 -9312 / Fax: (800) 791 -5500 Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY -B — 2.8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage G eneral not representative of all possible cor- rosive atmospheres. Consequently, it . - . is recommended that the end user be Description consulted with respect to the suitability .. 4 of these coatings for any given corro- .. °- • . The Series TV-B, 2.8, 5.6, and 8.0 sive environment. The effects of ambi- K- factor, Upright and Pendent Sprin- ent temperature, concentration of p kiers described in this data sheet are chemicals, and gas /chemical velocity, i standard response - standard cover- should be considered, as a minimum, ?' age, decorative 5 mm glass bulb type along with the corrosive nature of the -,'f' spray sprinklers designed for use in chemical to which the sprinklers will be ,°' light, ordinary, or extra hazard, corn- exposed. - mercial occupancies such as banks, An intermediate level version of the hotels, shopping malls, factories, refin- Series TY-B Pendent Sprinkler can be cries, chemical plants, etc. P obtained by utilizing the Series TY B The recessed version of the Series Pendent Sprinkler in combination with, TY-B Pendent Sprinkler, where appli- the Model S2 Shield. cable, is intended for use in areas with a finished ceiling. It uses a two -piece WARNINGS -1 Style 10 1/2 inch NPT) or Style 40 3/4 ` tY ( � tY ( The Series TY-B Sprinklers described f � '\ . N inch NPT) Recessed Escutcheon. The herein must be installed and main - 1 4r41* s Recessed Escutcheon provides 1/2 tained in compliance with this docu- i Inch (12,7 mm) of recessed adjust- ment, as well as with the applicable • ment or up to 3/4 inch (19,1 mm) of standards of the National Fire Protec- A. �� total adjustment from the flush pen- tion Association, in addition to the dent position. The adjustment provided standards of any other authorities hay- a ' - '''' the Recessed Escutcheon reduces `` by Y ing jurisdiction. Failure to do so may the accuracy to which the fixed pipe Impair the performance of these de- drops to the sprinklers must be cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain - applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is Model /Sprinkler IMPORTANT Identification t Always refer to Technical Data 10 Sheet TFP700 for the "INSTALLER Numbers E WARNING" that provides cautions with respect to handling and instal - TY1151 - Upright 2.8K, 1/2"NPT v lation of sprinkler systems and com- TY1251 - Pendent 2.8K, 1/2"NPT 2 ponents. Improper handling and in- TY3151 - Upright 5.6K, 1/2"NPT stallation can permanently damage TY3251 - Pendent 5.6K, 1/2"NPT °' a sprinkler system or its compo- TY4151 - Upright 8.0K, 3/4 "NPT cc nents and cause the sprinkler to fail TY4251 - Pendent 8.0K, 3/4 "NPT o to operate in a fire situation or cause TY4851 - Upright 8.0K, 1/2"NPT a cS it to operate prematurely. TY4951 - Pendent 8.0K, 1/2 "NPT } Page 1 of 8 JULY, 2004 TFP151 • Page 2 of 8 TFPI 51 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR ' = =� iv r7 — �i i ....�.i♦','.'*�`. 6 1 r 7 . !�i 5 2 -1/4" — P (55,6 mm) 2 -3/16° (57,2 mm) 11111M11111 4 �_ �l I 2 1 -9/16" WRENCH .1.1=1.111 6 ' I A (39,7 mm) ' FLATS ' � V, t� 3 �\ ■ff 7 SSP DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16° (11,1 mm) STYLE 10 PLATE SEATING 1/2" * * NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON SSU • — DEFLEC 1 DEFLECTOR �rr_ Ole - # rVV 6* 2-3/16° - � r 7/16" IM-6 5 (55,6 mm) 1 f1 �� �� ( 11,1 mm) � r m∎ MAKE-IN J I 4 (38.1 !mm) I �� 2 l (55,6 mm) itirei 1 - - WRENCH - i 0 � ` 3 A,.. �,�,_ . FL ATS 1 SSP DEFLECTOR* f— 2 -7/8" (73,0 mm) DIA. ---"'4 1/2" NPT 1 - PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw • * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT TFP151 Page 3 of 8 ESCUTCHEON 1/2° (12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED • - SURFACE NpT MAKE -IN ESCUTCHEON SSU* \ -----7- =_-_—_---=-- ----- DEFLECTOR 6 1/2° 'te 5 2 -5/16° ir (12,7 mm) (58,7 mm) II II 7 NOMINAL 4 i � _ MAKE -IN ii. 1 9/16° - �� lI '; lI 2-1/4° 2 (39,7 mm) ' �b, I (57,2 mm) Q' e l WRENCH 3 . -., FLATS 1 1 SSP DEFLECTOR " – 2 -7/8° (73,0 mm) DIA. -1 3/4° NPT 'PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Ejection orifice seat on frame. Screw Spring ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT ESCUTCHEON 7/16° (11,1 mm) PLATE SEATING 1/2° ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR 6 - -.._,--_-_-,_____- r 1m 5 2 -1/4" ,` —T 2 -3/16° (57,2 mm) �A III; +I ' (55,6 mm) I I 4 I ____ 1-9/16 ' WRENCH gli___ — ` ± :(i 2 (39,7 mm) FLATS � 7 • 4 If S 1 f 1 SSP DEFLECTOR CROSS . PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw . * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT • • Page 4 of 8 TFP151 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE••• LEAD WAX WAX OVER . LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 2.8 (TY1251) 1, 2, 3 N/A 1/2" and 175 °F /79 °C Yellow NPT UPRIGHT 200 °F /93 °C Green (TY1151) 286°F/141°C Blue 360 °F /182 °C Mauve 1, 2 ' 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3251) 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (1Y8151) 286 °F /141 °C Blue 1••,2••, 3••, 5 1•• 2••, 3'• 5°• 1/2° - I NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3251)• 175 °F /79 °C Yellow Figure 4 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4251) 1, 2, 5 1, 2, 3, 5 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 200 °F /93 °C Green 3/4° 286°F/141°C Blue 1 ••,2'•, 3'•, 5• ( 1", 2", 5" NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4251)• 175 °F /79 °C Yellow Figure 5 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4951) 1/2° and 175 °F /79 °C Yellow 1, 2, 3, 5 N/A NPT UPRIGHT 200 °F /93 °C Green (TY4851) 286 °F /141 °C Blue 360 °F /182 °C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53 -428- 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. •• 150 °F /66 °C Maximum Ceiling Temperature. ••• Frame and deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 2 -7/8" DIA. _ 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) .c......; (15,9±6,4 mm) 2 -1/4° DIA. 1/4" (6,4 mm) WRENCH RECESS FACE OF (57,2 mm) (END °A" USED FOR MOUNTING 1/2° NPT MODELS) SPRINKLER PLATE -' FITTING 1/8° WRENCH RECESS . _ '�' (3,2 mm) (END 18' USED FOR -------== 1 3/4° NPT MODELS) Al WM FIGURE 7 ��M � W -TYPE 6 SPRINKLER J 1 t ' . MOUNTING NA WRENCH SURFACE - -;- WRENCH CLOSURE SERIES 1 -1/4° (31,8 mm) RECESS TY-B 3/4" (19,1 mm) • • FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY • WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4" ...., '°' 5.6 K- FACTOR, 1/2 INCH NPT PUSH WRENCH INTO ENSURE 2 - 7/8" DIA. ENGAGEMENT (73,0 mm) 3/4" (19,1 mm) WITH SPRINKLER 5/8±1/4° WRENCHING AREA (15,9±6,4 mm) 2 -1/4" DIA. 1 1/4" (6,4 mm) (57,2 mm) FIGURE 8 FACE OF MOUNTING ' W -TYPE 7 RECESSED SPRINKLER PLATE SPRINKLER WRENCH FITTING 1/8" " (3,2 mm) /4 Ell . MOUNTING �: I SURFACE ■ CLOSURE SERIES 1 -5/16° (33,3 mm) TY-B 13/16° (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT Page 6 of 8 TFP151 ing the wax coating. Before wrench Technical Installation tightening the sprinkler, the jaws of the wrench are to be adjusted to just con - ata The Series TY B Sprinklers must be tact the sprinkler wrench flats. After installed in accordance with the follow- wrench tightening the sprinkler, loosen Approvals ing instructions: the wrench jaws before removing the UL and C -UL Listed. wrench. FM, LPCB, VdS, and NYC Approved. NOTES (Refer to Table A for complete approval Do not install any bulb type sprinkler if After installation, the sprinkler wrench information including corrosion resis- the bulb is cracked or there is a loss of flats and frame arms must be in- tent status.) liquid from the bulb. With the sprinkler spected and the wax coating re- Maximum Working Pressure held horizontally, a small air bubble touched (repaired) whenever the coat - 175 psi (12,1 bar) should be present. The diameter of th e ing has been damaged and bare metal air bubble Is approximately 1/16 inch is exposed. The wax coating on the Discharge Coefficient (1,6 mm) for the 135 °F /57 °C to 3/32 wrench flats can be retouched by gen- K = 2.8 GPM /psil/ (40,3 LPM/barl / inch (2,4 mm) for the 360 °F /182 °C tly applying a heated 1/8 inch diameter K = 5.6 GPM /psilI (80,6 LPM/barl / temperature ratings. steel rod to the areas of wax that have K = 8.0 GPM /psi / (115,2 LPM/bar been damaged, to smooth it back over A leak tight 1/2 inch NPT sprinkler joint areas where bare metal is exposed. Temperature Ratings should be obtained with a torque of 7 Refer to Table A to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- NOTES Finishes mum of 21 ft. lbs. (28,5 Nm) of torque Only retouching of the wax coating ap- Sprinkler: Reessed Escutcheon: White may be used to install sprinklers with plied to the wrench flats and frame Coated, Chrome Plated, or Brass 1/2 NPT connections. A leak tight 3/4 arms is permitted, and the retouching Plated inch NPT sprinkler joint should be ob- is to be performed only at the time of tained with a torque of 10 to 20 ft.lbs. the initial sprinkler installation. Physical Characteristics (13,4 to 26,8 Nm). A maximum of 30 Frame Bronze ft.lbs. (40,7 Nm) of torque is to be used The steel rod should be heated only to Button Brass/Copper to install sprinklers with 3/4 NPT con- the point at which it can begin to melt Sealing Assembly nections. Higher levels of torque may the wax, and appropriate precautions Beryllium Nickel w/Teflont distort the sprinkler inlet and cause need to be taken, when handling the Bulb Glass leakage or impairment of the sprinkler. heated rod, in order to prevent the Compression Screw Bronze installer from being burned. Do not attempt Copper pt to make -up for ins pp cient adjustment in the escutcheon If attempts to retouch the wax coating Bushing (K =2.8) Bronze plate by under- or over - tightening the with complete coverage are unsuc- sprinkler. Readjust the position of the cessful, additional wax can be ordered sprinkler fitting to suit. in the form of a wax stick (the end of Op eration which is color coded). Only the correct p The Series TY -B Pendent and Up- color coded wax is to be used, and The glass Bulb contains a fluid w right Sprinklers must be installed in retouching of wrench flats and frame The glass when exposed to head which When accordance with the following instruc- arms is only permitted at the time of the rated temperature is reached, the lions. initial sprinkler installation. With the fluid expands sufficiently to shatter the Step 1. Pendent sprinklers are to be steel rod heated as previously de- glass Bulb, allowing the sprinkler to installed in the pendent position, and scribed, touch the rod to the area re- activate and water to flow. upright sprinklers are to be installed in quiring additional wax with the rod an the upright position. gled downward, and then touch the wax stick to the rod approximately Design Step 2. With pipe thread sealant ap- one -half inch away from the area re- plied to the pipe threads, hand tighten quiring retouching. The wax will melt . Criteria the sprinkler into the sprinkler fitting. and run down onto the sprinkler. Step 3. Tighten the sprinkler into the . The Series TY B Pendent and Upright sprinkler fitting using only the W -Type The Series TY -B Recessed Pendent Sprinklers are intended for fire protec- 6 Sprinkler Wrench (Ref. Figure 7), Sprinklers must be installed in ac- tion systems designed in accordance except that an 8 or 10 inch adjustable cordance with the following instruc- with the standard installation rules rec- Crescent wrench is to be used for wax tions. ognized by the applicable Listing or coated sprinklers. With reference to Approval agency (e.g., UL Listing is Figures 1, 2, 3, and 4 the W -Type 7 Step A. After installing the Style 10 or based on the requirements of NFPA Sprinkler Wrench or the adjustable 40 Mounting Plate, as applicable, over 13, and FM Approval is based on the Crescent wrench, as applicable is to the sprinkler threads and with pipe requirements of FM's Loss Prevention be applied to the wrench flats. thread sealant applied to the pipe Data Sheets). Only the Style 10 or 40 threads, hand tighten the sprinkler into Recessed Escutcheon, as applicable, When installing wax coated sprinklers the sprinkler fitting. Is to be used for recessed pendent with the adjustable Crescent wrench, Installations. additional care needs to be exercised Step B. Tighten the sprinkler Into the to prevent damage to the wax coating sprinkler fitting using only the W -Type on the sprinkler wrench flats or frame 7 Recessed Sprinkler Wrench (Ref. arms and, consequently, exposure of Figure 8). With reference to Figure 3 or bare metal to the corrosive environ- 4, the W -Type 7 Recessed Sprinkler ment. The jaws of the wrench should Wrench is to be applied to the sprinkler be opened sufficiently wide to pass wrench flats. over the wrench flats without damag- Step C. After the ceiling has been in- TFP151 Page 7 of 8 stalled or the finish coat has been ap- The owner is responsible for the in- plied, slide on the Style 10 or 40 Clo- spection, testing, and maintenance of L imited sure over the Series TY 8 Sprinkler their fire protection system and de- and push the Closure over the Mount- vices in compliance with this docu- W arranty ing Plate until its flange comes in con- ment, as well as with the applicable tact with the ceiling. standards of the National Fire Protec- Products manufactured by Tyco Fire tion Association (e.g., NFPA 25), in Products are warranted solely to the C are and addition to the standards of any other original Buyer for ten (10) years authorities having jurisdiction. The in- against defects in material and work- stalling contractor or sprinkler manu- manship when paid for and properly Maintenance facturer should be contacted relative to installed and maintained under normal The Series TY B Sprinklers must be any questions. use and service. This warranty will ex- It is recommended that automatic ment Fire ten (10) years from date of ship- maintained and serviced in accord- ment by Tyco Fire Products. No war - ance with the following instructions: sprinkler systems be inspected, ranty is given for products or tested, and maintained by a qualified components manufactured by compa- NOTES Inspection Service in accordance with Hies not affiliated by ownership with Before closing a fire protection system local requirements and /or national Tyco Fire Products or for products and main control valve for maintenance codes. components which have been subject work on the fire protection system that to misuse, improper installation, corro- it controls, permission to shut down the sion, or which have not been installed, affected fire protection system must be maintained, modified or repaired in ac- obtained from the proper authorities cordance with applicable Standards of and all personnel who may be affected the National Fire Protection Assocla- by this action must be notified. tion, and/or the standards of any other Absence of an escutcheon, which is Authorities Having Jurisdiction. Mate - used to cover a clearance hole, may vials found by Tyco Fire Products to be delay the time to sprinkler operation in defective shall be either repaired or a fire situation. replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- Sprinklers that are found to be leaking sumes, nor authorizes any person to or exhibiting visible signs of corrosion assume for it, any other obligation in must be replaced. connection with the sale of products or Automatic sprinklers must never be parts of products. Tyco Fire Products painted, plated, coated or otherwise shall not be responsible for sprinkler altered after leaving the factory. Modi- system design errors or inaccurate or Pied sprinklers must be replaced. incomplete information supplied by Sprinklers that have been exposed to Buyer or Buyer's representatives. corrosive products of combustion, but IN NO EVENT SHALL TYCO FIRE have not operated, should be replaced PRODUCTS BE LIABLE, IN CON - if they cannot be completely cleaned TRACT, TORT, STRICT LIABILITY OR by wiping the sprinkler with a cloth or UNDER ANY OTHER LEGAL THE - by brushing it with a soft bristle brush. ORY, FOR INCIDENTAL, INDIRECT, Care must be exercised to avoid dam- SPECIAL OR CONSEQUENTIAL age to the sprinklers - before, during, DAMAGES, INCLUDING BUT NOT and after installation. Sprinklers dam- LIMITED TO LABOR CHARGES, RE- aged by dropping, striking, wrench GARDLESS OF WHETHER TYCO • twist/slippage, or the like, must be re- FIRE PRODUCTS WAS INFORMED placed. Also, replace any sprinkler that ABOUT THE POSSIBILITY OF SUCH has a cracked bulb or that has lost DAMAGES, AND IN NO EVENT • liquid from its bulb. (Ref. Installation SHALL TYCO FIRE PRODUCTS' LI- Section). ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Frequent visual inspections are rec THE FOREGOING WARRANTY IS ommended to be initially performed for MADE IN LIEU OF ANY AND ALL corrosion resistant coated sprinklers, OTHER WARRANTIES EXPRESS OR after the installation has been corn- pleted, to verify the integrity of the cor- IMPLIED. INCLUDING WARRANTIES rosion resistant coating. Thereafter, OF MERCHANTABILITY AND FIT - annual Inspections per NFPA 25 NESS FOR A PARTICULAR PUR- should suffice; however, instead of in- POSE. specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term Integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions • present. • Page 8 of 8 TFPI 51 r• ,., P/N 57 -XXX -X- XXX I I SPRINKLER TEMPERATURE MODEUSIN RATING 530 2.8K UPRIGHT (1/2 "NPT) TY1151 1 NATURAL BRASS 135 135 °F /57 °C 531 2.8K PENDENT (1/2 "NPT) TY1251 4 WHITE POLYESTER 155 155 °F /68 °C 570 5.6K UPRIGHT (1/2 "NPT) TY3151 3 WHITE (RAL9010)' 175 175 °F /79 °C 571 5.6K PENDENT (1/2 "NPT) TY3251 9 CHROME PLATED 200 200 °F /93 °C 590 8.0K UPRIGHT (3/4 °NPT) TY4151 7 LEAD COATED 286 286 °F /141 °C 591 8.0K PENDENT (3/4 "NPT) TY4251 6 WAX COATED 360 360 °F /182 °C 286 °F /141 °C MAX. 560 8.0K UPRIGHT (1/2 "NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT (1/2 °NPT) TY4951 286 °F /141 °C MAX. TABLE B • Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Wax.Sticks: Ordering Specify: Style (specify) Recessed Es- (for retouching wrench damaged • cutcheon with (specify finish), P/N wax coating) Procedure (specify). Specify: (Specify color) color coded When placing an order, indicate the full 1/2° (15 mm) Wax Stick for retouching (specify tern - product name. Refer to the Price List Style 10 perature rating) temperature rated Se- for complete listing of Part Numbers. Chrome Plated P/N 56- 701 -9 -010 ries TY B Sprinklers, P/N (specify). 1/2° (15 mm) Contact your local distributor for avail- Style 10 Black for 135 °F P/N 56-065-1-135 ability. White Color Red for 155 °F P/N 56-065-1-155 Coated P/N 56- 701 -4 -010 Yellow for 175 °F P/N 56 -065 -1 -175 1/2° (15 mm) Sprinkler Assemblies with NPT Style 10 Blue for 200 °F and Thread Connections: White RAL9010' P/N 56- 701.3 -010 286 °F P/N 56-065-1-286 Specify: (Specify Model /SIN), Stand- 1/2° (15 mm) and Response, (specify K- factor), Style 10 NOTES S temperature Brass Plated P/N 56- 701 -2 -010 Each wax stick is suitable for retouch - (specify P erature ratin g), Series 3/4° (20 mm) TY B (specify Pendent or Upright) Style 40 ing up to twenty-five sprinklers. Sprinkler with (specify type of finish or Chrome Plated P/N 56- 700 -9 -010 The wax used for 286 °F sprinklers is .. y coating), P/N (specify from Table B). style ao) the same as for 200 °F sprinklers, and, White Color therefore, the 286°F sprinkler is limited Coated P/N 56- 700 -4 -010 to the same maximum ceiling tempera - 3/4° (20 mm) tune as the 200 °F sprinkler (i.e., Style 40 150 °F). White RAL9010' P/N 56 -700 -3 -010 3/4° (20 mm) Style 40 Brass Plated P/N 56 -700 -2 -010 ' Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, • P/N 56- 850 -4 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446