Loading...
Permit CI1YOFTIGARD PERMIT #ERMIT ^ MST96 -0087 COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 08/22/96 13125 SW Hell Blvd. Tigard, Oregon 97223.8199 (503) 839 -4171 PARCEL: 2S1 1 ODB- 0020Zl0l SITE ADDRESS...: 15040 SW ROYALTY PKWY #L SUBDIVISION • WILLOWBROOK FARM /ARBOR HEIGHTS ZONING: R -25 BLOCK LOT •8 Remarks: BLDG L, 1 OF 14 MF UNITS sent plan review letter to services 0- 3/19/96 - BUILDING - REISSUE: STORIES • 3 FLOOR AREAS BASEMENT...: 2942 sf REQUIRED SETBACKS - - -- REQUIRED CLASS OF WORK.:NEW HEIGHT • 0 FIRST • 5884 sf GARAGE • 0 sf LEFT • 0 SMOKE DETECTRS: Y TYPE OF USE...:MF FLOOR LOAD • 0 SECOND...: 5884 sf FRONT • 0 PARKING SPACES: 0 TYPE OF CONST.:5 -1HR DWELLING UNITS: 28 FINBSMENT: 5884 sf RIGHT • 0 OCCUPANCY GRP.:R3 BDRM :42 BATH:42 TOTAL : 17652 sf VALUE..$: 1332779 REAR • 0 - - -- --- - - - - -- ---- - - - - -- PLUMBING SINKS • 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES • 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 Sf RAIN DRAINS: @ CATCH BASINS..: 0 TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREUNTR: 0 GREASE TRAPS..: 0 OTHER FIXTURES: 0 ____ -------- - - -_�_ MECHANICAL --_ -- FUEL TYPES----------- FURN ( 100K ..: @ BOIL /CMP ( 3HP: 0 VENT FANS • 42 CLOTHES DRYERS: 28 /ELE/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 28 OTHER UNITS...: 28 MAX INP.: 0 BTU. FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 0 — ----- - - - - -- - - - - -- ELECTRICAL — - -- RESIDENTIAL UNIT - -- -- SERVICE /FEEDER - - -- - -TEMP SRVC /FEEDERS -- - -- BRANCH CIRCUITS— -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 0 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR . 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 aap..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 PLAN REVIEW SECTION - Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =2 A.: ) 6' =" V NOMINAL: CLS AREA /SPC OCC: ELECTRICAL - RESTRICTED ENERGY - - - - -- A. SF RESIDENTIAL - -- B. COMMERCIAL AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: - - -- Contractor: TOTAL FEES:$ 23001.61 SECURITY CAPITAL PACIFIC TRUST CONTRACTOR NOT ON FILE SUITE 201 330 112TH AVE., NE BELLEVUE WA 98v Phone #: 206 -451 -9292 Phone #: Reg #..: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. - - - -- - - - - - -- REQUIRED INSPECTIONS Post /Beam Meehan Foundation Insp Plm /Underfloor Plumbing Top Out Insulation Insp Water Line Insp PLM /Underfloor Erosion Control Crawl Drain Framing Insp Shear Wall Insp Water Service In Mechanical Final Wtr Proofing Bsm Slab Insp Fireplace Insp Firewall Insp Appr /Sdwlk Insp Plumb Final Post/Beam Struct Plm /undslb Insp Gas Line Insp Gyp Board Insp Sprinkler Underf Footing Insp Post /Beam Mechan ech ca cei., s 2 Gas Fireplace Rain Drain Insp r, Rdd� Perm S ignature: _ I ssued By: Call for inspection — 639 -4175 CI TY OF TIGARD MASTER PERMIT PERMIT #.......: MST' 6 -008 7 • COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 08/24/96 13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 839 -4171 PARCEL: 25110DB -00200 SITE ADDRESS...: 15045 SW ROYALTY PKWY #L SUBDIVISION . WILLOWBROOK FARM/ARBOR HEIGHTS ZONING: R -25 BLOCK LOT -8 Remarks: BLDG L, 1 OF 14 MF UNITS sent plan review letter to services 0- 3/19/96 - BUILDING REISSUE: STORIES • 3 FLOOR AREAS BASEMENT...: 2942 sf REQUIRED SETBACKS -- REQUIRED CLASS OF WORK.:NEW HEIGHT : 0 FIRST • 5884 sf GARAGE • 0 sf LEFT • 0 SMOKE DETECTRS: Y TYPE OF USE...:MF FLOOR LOAD • 0 SECOND...: 5884 sf FRONT : 0 PARKING SPACES: 0 TYPE OF CONST.:5 -1HR DWELLING UNITS: 28 FINBSMENT: 5884 sf RIGHT • 0 OCCUPANCY GRP.:R3 BDRM:42 BATH:42 TOTAL - - - - -: 17652 sf VALUE..f: 1332779 REAR • 0 - -------- - ----- --- - - - -- — PLUMBING SINKS • 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES • 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0 TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0 OTHER FIXTURES: 0 -------------------- - - ---- --------- - - - - -- MECHANICAL FUEL TYPES-- - --- -- FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 42 CLOTHES DRYERS: 28 /ELE/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 28 OTHER UNITS...: 28 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES : 0 GAS OUTLETS...: 0 -------------------------- - - - - -- ELECTRICAL ---- - - - - -- - RESIDENTIAL UNIT - -- --- SERVICE /FEEDER --- —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS - -- - - -- MISCELLANEOUS - --- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 0 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/0 SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF H)1 /SVC /FDR: 0 601 - 1000 amp.: 0 601 +apps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 — - - - - -- PLAN REVIEW SECTION - Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - ----- - - - - -- ELECTRICAL - RESTRICTED ENERGY - - - - -- A. SF RESIDENTIAL B. COMMERCIAL — AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: .. BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: - - - - -- Contractor: -- TOTAL FEES:$ 23001.61 SECURITY CAPITAL PACIFIC TRUST DONALD M DRAKE CO SUITE 201 1740 NW FLANDERS ST 330 112TH AVE., NE BELLEVUE WA 98004 PORTLAND OR 97209 Phone #: 206- 451 -9292 Phone #: 620 -0868 Reg #..: 084045 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. - --------- - - - - -- --------- - - - - -- REQUIRED INSPECTIONS Post /Beam Mechan Foundation Insp Plm /Underfloor Plumbing Top Out Insulation Insp Water Line Insp PLM /Underfloor Erosion Control Crawl Drain Framing Insp Shear Wall Insp Water Service In Mechanical Final Wtr Proofing Bsm Slab Insp Fireplace Insp Firewall Insp Appr /Sdwlk Insp Plumb Final Post /Beam Struct Plm /undslb Insp Gas Line Insp Gyp Board Insp Sprinkler Underf Footing Insp Post /Beam Mechan Mechanical pp Mechanical Gas Fireplace Rain Drain Insp Additional Permittee Signature: r , lC.c k/�fj Issued By: 2. t' _ A ,Lal t' Call for inspection — 639 -4175 Commercial Building Permit Application • ' CAW of Tigard I/10r 13125 SW Hall Blvd. ARBOR HEIGHTS APARTMENTS BUILDING: l Tigard, OR 97223 L (503) 639 -4171 Jobsite Address: 1504 -5. SW ROYALT Pkwy Z -72 ,`;\.1 ,JY I $:';C` v.w:r4( 'µi}`i.. ..: : .ijkG.:'''rv: .Y�'I./�e'.o t� " "' :.k_ 3�d {raw : >: /...: %:.�`~ •. Tenant MF - 28 UNITS ...J S `'-: C�~: v..l1?:: \i - ' :� =<:.iti ( �= k � �t��{ iyi.`vv :: Y. -.J-'- 1. Vii.~.:- •.. }%:i ;: i• Valuation: 16 3 Z, 7 /9. 00 }: .Pem # <:: r 0087 `v Owner: Security Capital Pacific Trust' '� . n•.: -i;:: �` :,`•,::: �: v :. Y::.vt'r.' A.:: r..oy;Ji^C:4- 3'�.y. w,.::. ~.:. ::i?;G.r.`:...'�: >: :.'.;. Address: 330 112th Ave. NE # 201 Bellevue, Washington 98004 ;r. -N.. , . ... .:. fix' : ..: ;.:,:: ::' t',:OPlann .:i:']!:'•'ri::i Phone: (206) 451 -9292 i'•+ <.Engmeeri n • . :.f. S � v .. .. .t� . ~•. • ~ ...vk .: Please direct and questions or correspondance to owner agent, the architect listed below. :.............. :; �' � ;:;:: > : :;.:;; : }v: ; ?� <; > % }i_tiv:��': ?�':4n�j�:. y y�r '- ~?'aF4 {S" �. 'h�- }�h� } }x,`�-"gd,3n: -.. 9'. . :+i -n i v Contractor: - DOIJALD DRA -E Gm F: Ia...R ~ti > :a d .. '~. , kr . ; �,i? : a'! di } : : . b ..`,..1:":Ctia1R:',`•xwv'.1'• :M V K4W4ft `>~.. .. .:Y_e Address: Aq Type V- 1 hour 4J\ Type of coast \`‘ Occupancy class: R -1 Phone: Sprinklered? 4230 No • Contractor's License (attach copy of argent Oregon license) 5q. ft. or project Contact name & phone: DR ULE VA!J fr111e ZZ - 3 6 r1 f Story (1st, 2nd, etc.) BASEMEIJT I , 2., 3 Proposed use: Residential Architect/Engineer: Riebe and Associates. Inc. Previous ;ma,: None - new construction • Address: 2110 116th Ave. NE Note: Plumbing & mechanical plans Bellevue. Washington 98004 must be submitted at time of building permit application. Phone: (206) 451 -4084 (Contact Person: E. Dennis Riebe) JOB DESCRIPTION: New Construction of Multifamily Residential Dwellings. This building is a part of a 348 unit apartment complex. L Applicant Signature & Phone number Received by: o-rrJ Date Received: 02214 ( Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0087 SECURITY CAPITAL PACIFIC TRUST 15045 SW ROYALTY PKWY Unit: L • 10/26/98 Action Description Reg/ ' Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA026 Plans approved by Plans Exmr ' / / / / 04/01/96 PASS MS 04/01/96 MRS MSTA717 PLM /Underfloor / / / / 11/15/96 PASS TLP 12/06/96 TLP MSTB005 Application received - / / / / / / 03/10/96 J *H MSTB008 Permit created / / / / / / 03/10/96 J *H MSTB010 Check for prcl. restrict. / / / / / / 03/10/96 J *H MSTB012 Plans routed to Plans Examiner / / / / / / 03/10/96 *H MSTB026 Plans approved by Plans Exmr / / / / 03/20/96 PASS MJR 03/20/96 MJR MSTB026 Plans approved by Plans Exmr 05/03/96 / / 06/04/96 JHF 06/05/96 JHF • MSTB030 Reviewed plans routed to DSTS / / / / 03/20/96 letter attached YES , MJR 03/20/96 MJR MSTB030 Reviewed plans routed to DSTS 06/05/96 / / 06/05/96 hold for spl insp forms [2] APPR JHF 06/05/96 JHF MSTB090 (F) Ready to issue / / • / / 08/06/96 PASS JMH 08/06/96 J *H MSTB098 (F) Issue combination permit / 7 / / 08/22/96 PAID JMH 08/22/96 J *H MSTB098 (F) Issue combination permit / / / / 08/22/96 08/22/96 J *H • MSTB105 (F) Reprint Permit / / / / 08/24/96 OOPS JMH 08/24/96 J *H MSTB705 Footing Insp / / / / 11/15/96 PASS TLP 12/06/96 TLP MSTB706 Foundation Insp 11/15/96 / / 11/15/96 PASS TLP 08/06/98 TLP MSTB708 Erosion Control / / / / / / 03/10/96•J *H MSTB709 Wtr Proofing Bsm't Walls / / / / / / 03/10/96 J *H MSTB710 Post /Beam Structural / / / / 02/03/97 . PASS TLP 08/06/98 TLP MSTB711 Post /Beam Mechanical / / / / / / N/A 08/06/98 TLP MSTB712 Plm/Underflbor / / / / 02/03/97 PASS TLP 02/04/97 TLP MSTB713 Crawl Drain / / / / / / N/A 08/06/98 TLP MSTB715 Slab Insp / / / / 12/20/96 PASS TLP 12/26/96 BT2 MSTB720 Plm /undslb Insp / / / / 12/20/98 PASS TLP 08/06/98 TLP MSTB725 Mechanical Insp / / / / / / N/A 08/06/98 TLP MSTB727 Plumbing Top Out / / / / 07/02/97 not ready FAIL RAB 08/19/98 TLP MSTB730 Framing Insp / / / / 07/22/97 PASS -TLP 07/27/97 J *H MSTB735 Fireplace Insp / / / / 07/22/97 PASS TLP 08/06/98 TLP MSTB740 Gas Line Insp / / / / / / N/A TLP 08/19/98 TLP MSTB741 Gas Fireplace / / / / / / N/A TLP 08/19/98 TLP MSTB745 Insulation Insp / / / / 07/28/97 PASS TLP 08/06/98 TLP MSTB750 Shear Wall Insp / / / / 05/22/97 PASS TLP 05/27/97 TLP , MSTB755 Firewall Inap 07/29/98 / / 07/29/98 PASS TLP 08/06/98 TLP MSTB760 Gyp Board Insp / / / / 07/29/97 PASS TLP 07/30/97 J *H MSTB779 Rain Drain Insp / / / / 11/15/96 PASS TLP 12/06/96 TLP MSTB780 Water Line Insp / / / / / / N/A TLP 08/19/98 TLP MSTB781 Water Service Insp / / / / 05/07/97 PASS TLP 05/08/97 TLP MSTB785 Appr /Sdwlk Inap / / / / / / 03/10/96 J *H MSTB786 Sprinkler Underfloor /slab / / / / 05/07/97 PASS TLP 08/19/98 TLP . MSTB787 Sprinkler Rough -In 07/22/97 / / 07/29/97 PASS TLP 08/06/98 TLP MSTB788 Sprinkler Final / / / / 10/24/97 PASS TLP 08/06/98 TLP MSTB789 Smoke Detector / / . / / 10/24/97 PASS TLP 08/06/98 TLP MSTB790 Fire Alarm Insp 10/24/97 / / 10/24/97 PASS TLP 08/06/98 TLP • Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0087 SECURITY CAPITAL PACIFIC TRUST 15045 SW ROYALTY PKWY Unit: L 10/26/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTB797 Plumb Final / / / / 10/24/97 28 units approved. PASS MS 11/06/97 J *H MSTB799 Building Final 10/24/97 / / 10/24/97 PASS TLP 08/06/98 TLP MSTD095 Issue plumbing signature form / / / / 04/23/97 REC'D SIGN PLM FORM PASS JT 04/23/97 RB MSTD097 Issue Electric Signature Form / / / / 04/28/97 REC'D SIGN ELEC FORM OASS JT 04/28/97 RB MSTD400 Devel review cond. met / / / / 09/30/98 APPR JDA 09/30/98 JDA MSTD712 Plm /Underfloor / / / / 07/07/97 PASS RAB 07/08/97 J *H MSTD723 Electrical Service 07/14/97 / / 07/10/97 Service okay, rough -in okay PASS BRP 07/14/97 J *H MSTD724 Electrical Rough -in 07/14/97 / / 07/10/97 PASS BRP 07/14/97 J *H MSTD727 Low Voltage 07/14/97 / / 10/21/97 PASS BRP 10/29/97 J *H MSTD730 Framing Insp • / / / / 07/18/97 PASS TLP 07/30/97 J *H MSTD796 Electrical Final 07/14/97 / / 10/21/97 PASS BRP 10/29/97 J *H MSTD950 (F) Issue Cert. of Occupancy / / / / 10/24/97 to jill for, c/o approval 8/25/98 10/08/98 JT 9/30/98 to David for sig. 10/8/98 mailed to site, owner, contractor • • • • •