Loading...
Permit 1 � CITY OF TIGARD MASTER PERMIT DEVELOPMENT SERVICES PERMIT # DATE ISSUED: 03/08/9 MST99 -084 9 �� ® � '� -. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PARCEL: 2S102BC -07400 SITE ADDRESS•..:1263O SW PATHFINDER CT SUBDIVISION •PP1997 -113 ZONING: R -4.5 BLOCK LOT •001 JURISDICTION: TIG Remarks: Construction of single family detached, Path 1. BUILDING REISSUE: STORIES : 2 FLOOR AREAS -- BASEMENT...: 0 sf REQUIRED SETBACKS— REQUIRED- - CLASS OF WORK.:NEW HEIGHT • 22 FIRST • 1287 sf GARAGE • 648 sf LEFT : 50 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1134 sf FRONT • 20 PARKIN SPACES: 2 TYPE OF CONST.:5N DWELLING UNITS: 1 FINBStENT: 0 sf RIGHT • 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL : 2421 sf VALUE..$: 184889 REAR • 25 PLUMBING SINKS • 2 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 100 TRAPS • 0 LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1'" SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1Y. BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 — MECHANICAL - FUEL TYPES FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 GAS FURN ) =1001( ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES....: 0 GAS OUTLETS...: 1 - ELECTRICAL - - RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— —BRANCH CIRCUITS — — MISCELLANEOUS— --ADD'L INSPECTIONS - 1m SF OR LESS: 1 0 - 200 alp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 4 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1m amp.: 0 601 +amps -lm v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 - — PLAN REVIEW SECTION ------- -- -- Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) . V NOMINAL: CLS AREA /SPC OCC: — ELECTRICAL - RESTRICTED ENERGY — ______ - ___ ___ - _____ - A. SF RESIDENTIAL B. COMMERCIAL - -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO $ STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: X 0TH: .. BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: X CLOCK • INSTRUMENTATION: MEDICAL • OTHR: :: HVAC • X DATA /TELE COMM.: NURSE CALLS • TOTAL R SYSTEMS: 0 Owner: - --Contractor: - -- -- TOTAL FEES:$ 5224.46 MARK NYDIGGER OWNER This permit is subject to the regulations contained in the 9315 SW COMMERCIAL SIGNED RESPONSIBILITY FORM Tigard Municipal Code, State of Ore. Specialty Codes and all TIGARD OR 97223 IN FILE other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone 0: 639 -4033 Phone B: not started within 180 days of issuance, or if the work is Reg B..: suspended for more than 180 days. ATTENTION: Oregon law -- — requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. — - REQUIRED INSPECTIONS Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final Post /Beam Struct Plumb Top Out Low Voltage Appr /Sdwlk Insp Post /Beam Mechan Electrical Servi Gas Line Insp Electrical Final Issued By: Ji3 r......, Permittee Signature /. - /_,v -2,A.---"" + + + + + + + + ++ + + + + + + + + + + + + + + + + + + + +, + + + + + + + + + ++ + ++ . + ++ Call 639 -4175 by 7:00 p.m. for an inspection needed he next business day , A._ a. Plan Check # U a $cyd_ CITY OF TIGARD Residential Building Permit Application Rec'd By 1,- 13125 SW HALL BLVD. New Construction Additions or Alterations Date Rec'd g--, TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.C. 3 - - l IZ, V 503 - 639 -4171 Date to DST 3 - & F 503 - 684 -7297 Permit # MgT99'' Print or Type ' ' Called 2 , - C t - 4 tq — vb tcowwu L Incomplete or illegible applications will not be accepted t145 t•1 14.)i2Q7_ (2DSO Name of Project Name Job (1 yd'Ij s e f om ‘c._ Qv a,t o', rA OhS v■ Address Site Address Architect Mailing Addreh 1 21 30 s W Po��\1�'.r. �er G 41 15 .5V./ G ft-t n' vfq col A 1 Name City /State Zip Phone r4No∎r�) VJonn� `(� &6,,?3er N ®r ( 3”.7- �bZy`bs� 'if Owner Mailing Address 9%3 1S SW C - O ff., o v a c.'% OA g City /State Zip Phone Engineer Mailing Address "r%q t)..r d ■c . 6 1)223 6361 - yo33 City/State Zip Phone General Name Contractor lcar\c r'd •� 4 q e I (owA « ) Describe work New k Addition 0 Alteration 0 Repair 0 Mailing Address V Vv J to be done: Prior to permit 0.6, oft_ t_ Additional Description of Work: issuance, a copy City /State Zip Phone of all licenses - are required if Oregon Const. Cont. Board Exp. Date PROJECT • expired in COT Lic.# VALUATION $ database • �P �� Q �j 'Z , b1 y f Mechanical Name NEW CONSTRUCTION ONLY: GA"( 34 a f - & i-u Sub Yea( \G 'f\� [I A Qr Sq. Ft. House: 1 Sq. Ft. Garage Contractor Mailing Address U Prior to permit (..1.4313V e., Corner Lot YES NO Flag Lot YES ' NO issuance, a copy City /State Zip Phone (check one) )( (check one) of all licenses Restricted Audio /Stereo Burglar are required if Oregon Const. Cont. Board Exp. Date Energy System Alarm expired in COT Lic.# Y database Installation Garage Door HVAC Plumbing Name X Opener Systems Sub - 6 ,,.. 'nV Jj , y 4 v r (check all that Other: Contractor Mailing Address uu �J apply) Will the electrical subcontractor wire for all YES NO 60 ti c4.. • restricted energy installations? Prior to permit City /State Zip Phone \ Has the Subdivision Plat recorded? N/A / NO issuance, a copy of all licenses are Oregon Const. Cont. Board Exp. Date required if Lic.# Reissue of MST #: Solar Compliance expired in COT (Calculation Attached) database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized Name agent of the owner, and that plans submitted are in compliance with Oregon State laws. Electrical (i ' t \, : k J► . ,y q t ( Signature of Owner /Agent Date Sub- Mailing Address ° aZ - ,R6- F9 Contractor c7 b o v Contact person Name Phone # 7 City/State Zip Phone mark (Iva i. p . o e / 63 a3 Prior to permit FOR OFFICE USE•ONLY: issuance, a copy of all licenses are Oregon Const. Cont. Board Exp. Date Plat #:� n / T y 7_113 LD / L #, aEC -67 c10 4 required if Lic.# S Zone' Solar. ii/ expired in COT ,4 9 �^ �, j database Electrical Lic. # Exp. Date /U E kt ri pproval: PLaiming Approval: TIF: l � w �� ^ e ,,��//�� � , / /9:_a_ P u,i 1 1 t Cl alr, e4Q 02-,,,, Ei � 4 0 ^C�vs� �4 J I`,Q �� I :SFREM.DOC (DST) 4/97 S t i 79' 60(' w/Ja-4 5 44'40%"^-° • • Permit #: - T -C t C t - DO` / O O "`''�` Address: I !—l2 0 6 to J C � k vigzrimo:t pu.111.-1411--w-ii.::)z . .• Issued by: 6 eor +--- Date: 3- CC - 6 H \=5g Statement: Information Notice to Property Owners About Construction Responsibilities Note: Oregon Law, ORS 701.055(4), requires residential construction permit appli- cants who are not registered with the Construction Contractors Board to sign the following statement before a building permit can be issued. This statement is required for residential building, electrical, mechanical, and plumbing permits. Licensed architect and engineer applicants, exempt from registration under ORS 701.010(7), need not submit this statement. This statement will be filed with the permit. Fill in the appropriate blanks and initial boxes 1 and 2, and either box 3A or 3B: 4 - ' 1. I own, reside in, or will reside in the completed structure. 2. I understand that I must register as a construction contractor if the structure is sold or offered for sale before or upon completion. ri 3A. My general contractor is (Name) Contractor regis. # I will instruct my general contractor that all subcontractors who work on the structure must be registered with the Construction Contractors Board. OR / V 3B. I will be my own general contractor. If I hire subcontractors, I will hire only subcontractors registered with the Construction Contractors Board. If I change my mind and hire a general contractor, I will contract with a contractor who is registered with the CCB and will immediately notify the office issuing this building permit of the name of the contractor. I hereby certify that the above information is correct and that I have read and do understand the Information Notice to Property Owners about Construction Responsibilities on the reverse side of this form. %� %ref ".-w ? ��'9 1 (Signature of pe t applicant) (Date) (White copy to issuing agency permit file, pink copy to applicant) Information Notice to Property Owners About Construction Responsibilities .Note. Thi ,,naiio;2 .Notice to Property Owners about Construction Responsibilities was Liccci';pco ''v t%:c• Coil iruction Co:itractors Board in accordance with ORS 701.055(5). 11 ou are acting as your own ' 'ntra' tor to ct!nstruct %I new home or make a stibstanlial impro‘cment to an existing structure, you can present many prohlein�, by being aware of the following responsibilities and areas of concern. EMPLOYER RESPONSIBILITIES: If you hire persons not reg ,,lt : d x. ith the Construction Contractors Board to do labor in constructing or assisting in the constriction or imp:ovement ,,t. a residential structure, you will, in most instances, be ruled to be an employer and the people you hire will be employees. A, the employer, you must comply with the following: Oregon's withholding tax law': As an entplbyer, you must withhold income taxes from employee wages at the time employees are paid. You ill he liable for the tax payments even if you don't actually withhold the tax from your employees. For more information, call the Oregon Dept. of Retienue at 945 -8091. Unemployment insurance tax: As ,n employer, y■ou are recuired to pay a tax for unemployment insurance purposes on the wages of a ll employees. Fo r it kin call the Oregon Employment Division at the Department of Human Resources at 378 -3524. Workers' compensation insurance: As an employer. you are subject to the Oregon Workers' Compensation Law, and must ohtain workers' compensation ilIsurancc for y our employees. If you fail to obtain workers' compensation insurance, you may he subject to penalties and NA ill he liable for all claim costs if one of your employees is injured on the job. For more information, call the Workers' Compensation Division at the Department of Consumer and Business Services at 945 -7888. U.S. Internal Revenue Serviice: As an employer, you must 'a ithhold federal income tax from employees' wages. You will be liable for the tax payment even I f you didn't actually v ithhold the tax. For more information, call the Internal Revenue Service at 1-800-829-1040. OTHER RESPONSIBILITIES AND AREAS OF CONCERN: Code compliance: As the permit holder for this project, you are responsible for resolving any failure to meet code requirements that may be brought to your attention through inspections. Liability and property damage insurance: Contact your insurance agent to see if you have adequate insurance coverage for accidents and omissions such as falling tools, paint overspray, water damage from pipe punctures, fire, or work that must be re -done. Time to supervise employees: Make sure you have sufficient time to supervise your employees. Expertise: Make sure you have the expertise to act as your own general contractor, to coordinate the work of rough -in and finish trades, and to notify building officials at the appropriate times so they can perform the required inspections. If you have additional questions, write or call the Construction Contractors Board (PO Box 14140, Salem, OR 97309 -5052, 503/378- 4621). The Board is located at 700 Summer St. NE Suite 300, in Salem. prop- own.pm4 1 /94 • • ROAD MAINTAINANCE AGREEMENT This agreement is made this day of February, 1998 and is meant to establish a access road construction and maintenance agreerrient between the owners of Parcels 1 & 2 of Partition Plat No. 1997 -11-3 and recorded as document No. 97113736, recorded and located in Washington county, Oregon. These parcels are hereby also known as the "property". The Partition Plat provides a 15 foot wide access easement, hereby also known as the "road" which connects the building sites of the property to Pathfinder Ct. The Owners desire to provide for a common access to the property building sites connecting to SouthWest Pathfinder C9urt. The terms of the construction and maintenance of the road applies only to the area within the access easement. THE OWNERS AGREE: • • 1. Description of Road to be Constructed and Maintained. The area of the road to be constructed and maintained shall be a distance of no more than 80 feet from the property line at Pathfinder Ct. back towards the rear of the property, or to the far edge of driveway apron of each property, whichever is less. The road shall be constructed to allow access to both lots with design to be approved by owners of both parcels. The sidewalk and curb where the road meets Pathfinder Ct. shall be considered part of the road to be constructed and maintained as described in the following sections. The curb and sidewalk shall be constructed to the minimum • standards required by the City of Tigard. 2. Construction and Maintenance. The area of the road to be constructed and maintained shall be initially paved with asphalt to a width of 10 feet or the minimum standard required by the City of Tigard, whichever is less, and further constructed to the City of Tigard minimum load limits. The width of the road shall be split evenly between the two properties. The road area shall have adequate drainage. The road shall be installed by the first owner to complete a residence on either parcel within 30 days after completion of the dwelling. The road shall be maintained as a asphalt road and when necessary to keep it structurally sound. 3. Construction Expenses. It will be the responsibility of the owners of the property that build a residence on their property to equally share in the costs of construction of the access road up to the length required for the first residence built. In the event that a owner builds a residence and installs the access road prior to the other property owner's construction of a residence, the last owner to build a residence shall reimburse the first owner, that installed the access road, one half of their true costs of installing the access road to the first residence within 30 days after completion of the second parcel's residence. The last owner to build a residence shall be totally responsible for construction costs of any additional length of road from first owners road construction. 4. Maintenance Expenses. Each Parcel of the Property shall contribute equally to the maintenance of the entire access road. 5. Repair for Excessive Use. If any owner should damage any portion of the roadway by reason of construction, as might occur by opening road for installation or repair of utilities, or excessive or hefa,s wgaviEt, Donstruction, (X) < 1 ROAD MAINTENANCE AGREEMENT • (JC)�_____ ` ___ (X 5/17/00 Activities for Case #: MST99 -00084 2:31:41 PM . Assigned Hold Updated • ' Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 2/26/99 GEO RECD DRA 3/4/99 MSTA008 Permit Created 3/4/99 DEB DONE DRA 3/4/99 Delay in creating due to waiting for approval of yard definitions by Planning Dept. Julia H approved the setbacks of the house placement on 3 -3 -99. MSTA010 Check for prd. restrict. 3/3/99 DEB DONE DRA 3/4/99 MSTA012 Plans routed to Plans Examiner 3/4/99 DEB DONE DRA 3/4/99 MSTA026 Plans approved by Pln Examiner 3/8/99 RT PASS BT2 3/8/99 MSTA030 Reviewed plans routed to DSTS 3/8/99 RT PASS BT2 3/8/99 MSTA032 DST Post - Review Completed 3/8/99 B DONE BON 3/8/99 MSTA700 Erosion 844 -8444 DRA 3/4/99 MSTA705 Footing Insp 4/7/99 RC PASS AKJ 4/7/99 MSTA706 Foundation Insp 4/7/99 RC PASS . AKJ 4/7/99 MSTA710 Post/Beam Structural 5/17/99 KS PASS AKJ 5/17/99 Provide gussets at each side of girders at splice Add post at notched girder at front of structure MSTA711 Post/Beam Mechanical DRA 3/4/99 MSTA713 Crawl Drain /Backwater valve 4/15/99 GS PASS AKJ 4/15/99 MSTA717 PLM /Underfloor 5/10/99 TLP PASS AKJ 5/10/99 MSTA720 Mechanical Insp 10/26/99 KBS FAIL KBS 10/26/99 #-1- see framing notes this date MSTA722 Plumb Top Out 10/12/99 MS PASS JS 10/12/99 MSTA723 Electrical Service 10/12/99 CD FAIL JS 10/12/99 1. Use approved clamp on rebar 2. Rebar connection must remain accessible 3. Use approved crimping tool & twist wires per manufactures requirements 4. Isolate grounds & neutrals in sub panel 5. Add outlet within 6" of door in dining room 6. Ground dryer box 7. Ground access lights with approved crimping tool 8. Intertie smoke detector with 3 wire cable 9. NM cable connectors required on all metal boxes 10.Veryfy speaker wire • . jacketing Page 1 of 4 5/17/00 Activities for Case #: MST99 -00084 . • 2:31:41 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To • Done By Disp. Level By Updated Notes • MSTA724 Electrical Rough In 10/12/99 CD FAIL JS 10/12/99 See Service 10/12/99. MSTA725 Framing Insp 10/12/99 KS FAIL • JS 10/13/99 1. Need electrical cover (app) • prior to framings & mechanical. MSTA726 Shear Wall lnsp 10/13/99 KS • PASS • AMS 10/14/99 MSTA728 Low Voltage 10/26/99 KBS DONE KBS 10/26/99 See Service 10/12/99. MSTA735 Gas Line Insp 10/22/99 KBS FAIL JS 10/22/99 MSTA740 Insulation Insp 11/8/99 ' KS PASS VT 11/8/99 . . MSTA752 Rain drain Insp 4/15/99 GS PASS AKJ 4/15/99 Note: There is a section of sewer pipe installed under garage, ok to cover this section MSTA761 Water Service lnsp 4/16/99 GS PART AKJ 4/18/99 Sleeve for water service is ok MSTA790 Electrical Final 10/22/99 CD PASS • JS 10/22/99 Service approved. MSTA795 Mechanical Final 5/9/00 RB FAIL AKJ 5/10/00 see bldg final 5/9 MSTA797 Plumb Final _ 5/5/00 MRS FAIL AKJ 5/7/00 req hot water, call back . • MSTA799 Building Final 5/9/00 • RB FAIL AKJ 5/10/00 owner occupied 1) change dryer duct to smooth pipe . 2) seal holes in gar wall • between dwelling/gar . a/c not installed, not part of this '- permit • MSTA080 (F) Ready to issue 3/8/99 B MEMO BON 3/8/99 Must sign owner responsibility . form. MSTA092 (F) Issue combination permit 3/8/99 B • PASS BON 3/8/99 MSTA729 Special insp. required 3/9/99 JMT NOTE JT 3/9/99 Not a special inspection, but a note: there's a geotech review . • for retaining wall in file. Also pictures of site. . MSTA714 Footing /Foundation Drain 4/15/99 4/15/99 4/15/99 GS PASS No Hold AKJ 4/15/99 . MSTA704 Sewer Inspection 4/16/99 GS PASS No Hold AKJ 4/18/99 . MSTA760 Water Line Insp 5/11/99 5/11/99 5/11/99 TLP PASS No Hold AKJ • 5/11/99 MSTA795 Mechanical Final 10/13/99 10/13/99 10/12/99 KS FAIL No Hold JS 10/13/99 See Building framing. 10/12/99 MSTB727 Low Voltage 10/19/99 10/19/99 10/19/99 CD FAIL No Hold • JS 10/19/99 Repair splice next to funace and garage main door still using wrong crimping tool on ground • splice speaker wire varification? Call me regarding panel ground baz. MSTA723 Electrical Service 10/22/99 10/22/99 10/22/99 CD PART No Hold JS 10/22/99 Rough in approved only • MSTA728 Low Voltage 10/22/99 10/22/99 10/22/99 CD PART No Hold JS 10/22/99 Page 2 of 4 5/17/00 Activities for Case #: MST99 -00084 2:31:41 PM Assigned Hold Updated • Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 10/22/99 10/22/99 10/22/99 KBS FAIL No Hold JS 10/22/99 Need electrical cover approved prior to fram/ mechanical inspetion. Inspection made • p.m. per request. Re- schedule ater electrical cover is (approved). MSTA725 Framing Insp 10/26/99 10/26/99 10/25/99 FAIL No Hold KBS 10/26/99 #-1- positive connection trimmers to garage header #-2- add stud @ plate splice rear garage wall #-3- provide king studs © each side of glu /lam @ garage & nail to glu /lam also strap plates to glu /lam same location • #-4- support under hips © garage #-5- -strap plates to header © din /mi horixontal . ti-6- provide full bearing under beam adjacent to stairs ##7- positive connection glu/lam • to post @ liv /rm also strap • splice top plate less than four ft apart #-8- fireblockstairs / landing #-9- provide full bearing girder truss clips each side #-10-- provide attic access • #-11 -block around fireplace vent #-12- extend gas piping to all • appliances #-13- extend B vent above upper roof line MSTA735 Gas Line lnsp 10/26/99 10/26/99 10/26/99 KBS FAIL No Hold KBS 10/26/99 #-1- see framing notes this date MSTA725 Framing Insp 11/1/99 11/1/99 11/1/99 KS PART No Hold VT 11/1/99 provided full bearings under glu/lam @ left side of garage. Complete fireblockings @ stairs. • MSTA735 Gas Line Insp 11/1/99 11/1/99 11/1/99 KS PASS No Hold VT 11/1/99 gas pippins p.t. test =25 P.S.I. for 20 minutes gas #380006 MSTA720 Mechanical lnsp • 11/1/99 11/1/99 11/1/99 KS PART No Hold VT 11/1/99 clothes dryer not vented. Lower level return air not connected. okay to insulate . call for • reinspection item listed above when completed. MSTA725 Framing lnsp 11/3/99 11/3/99 11/3/99 KBS PASS No Hold VT 11/3/99 MSTA720 Mechanical Insp 11/3/99 11/3/99 11/3/99 KBS PART . No Hold VT 11/3/99 retum air @ garage not connected @ this time. Flex • duct not allowed? Page 3 of 4 5/17/00 Activities for Case #: MST99 -00084 2:31:41 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA797 Plumb Final 5/8/00 MRS PASS No Hold AKJ 5/8/00 MSTA790 Electrical Final 5/9/00 CD PASS No Hold AKJ. 5/9/00 MSTA795 Mechanical Final 5/11/00 RB PASS No Hold AKJ 5/11/00 MSTA799 Building Final 5/11/00 RB PASS No Hold AKJ 5/11/00 MSTA960 (F) Issue Cert. of Occupancy 5/11/00 RB DONE No Hold ST 5/17/00 5 /17 /00- mailed to owner /file • • Page 4 of 4 CITY OF TIGARD BUILDING INSPECTION DIVISION �I, 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 "�■� �� ��� BUP Date Requested 5/ n 1/00 AM PM BLD Location ■ D / _AA A /A ! I 6 Suite (, MEC 1' W Contact Person Ph j / Q - Y0 0 3 PLM Contractor Ph SWR CBUILDIN Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain / Crawl Drain Inspection N =. I S7 Q.� ]� S� ? S GN Slab SIT Post & Beam !!! Ext Sheath /Shear q / Li Ga,Q, /' WAG.5 — 11$ �• Int Sheath /Shear Framing ? Nr-" c � v Insulation Drywall Nailing M 6 - 01_,V\ • Q l Fire wall I S S ^_ / Z � \ � Fire Sprinkler 1 �.� — T "�/� 01 Fire Alarm Susp'd Ceiling Roof Misc: S S PART FAIL • I BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Dins Final'✓ PASS PART FAIL 11ECHANIC9v Post & Beam Rough In Gas Line S . • e Dampers PART FAIL CTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk �� Date � U Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 99 k y 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested n s�Q /oO AM x PM BLD Location VO D .P 1�1�11 /,�.Q- Suite MEC y Contact Person (A1- Ph (A ;5 / PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Claw l Drain Inspection Notes: � „f G �� � 1n^ Post & Beam r Y v SIT Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler 1 Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL • PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL LECTRIC Service Rough In UG /Slab Low Voltage • e Alarm Fiy • • SSA PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: /// [ ] Unable to inspect - no access ADA �^ _ - Approach /Sidewalk D a t e _ ] Ins v // Other i Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 99-coogy 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP Date Requested $/ 9 /Oa AM PM x BLD Location I 3- (1) 2 0 1 47/111,/t-- Suite MEC Contact Person Yr lt2}4- Ph ti 39 /D 33 PLM Contractor Ph SWR UI Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain InspeCti• a ' - , A SGN Slab /y is SIT Post & Beam Ext Sheath /Shear ['QUA q "- /r/ f %,/ s J ? 4' Int Sheath /Shear Framing Insulation /� n , ��., p Drywall Nailing v v 1 �(� X Firewall Fire Sprinkler Fire Alarm _( * +) 5 "t1 n Susp'd Ceiling � d-V � Cam- � Roof Misc: e\e-iz-- '.S PART AIL PLUMBING (4) S L./k■. c V ll■ Post & Beam Under Slab C Ax. 1 L...._` G • Top Out Water Service Sanitary Sewer Rain D ins Final PASS PART FAIL ANIC Post & Beam • hi 4 AL 1111 Rough In �—. Gas Line Smok KfbA o-,---t- O ^' S eriria ,) - PASS PART ge /� p j T ELECTRICAL / (/" Service Rough In UG /Slab Low Voltage Fire Alarm Final P_ S PART FAIL :ackfill /Grading Sanitary Sewer ^ O Storm Drain A 1 � h [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin "11 V ` Y Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA _ Ap • roach /Sidewalk 0 6•1(6514'' Date C Inspector \-/ Ext Final " PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST q'q -n0 $ 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested S/ D o f O AM PM BLD Location 12—(0 3D f A- 14 // G4/L Suite MEC Contact Person 0/1 U` Ph Co _ 9 — `7 d PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: • Final PASS PART FAIL - . 1 11EIMM Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rai ' rains 1�� PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date a-6 Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.