Loading...
SGN2012-00078 p CITY OF TIGARD SIGN PERMIT ;NI Permit #: SGN2012 -00078 COMMUNITY DEVELOPMENT Date Issued: 05/11/2012 T f (j r1 R D 13125 SW Hall Blvd., Tigard OR 97223 503.718.2421 Parcel: 1 S135AB01003 Jurisdiction: TIGARD Name of Business: Red Lobster Business Address: 10330 SW GREENBURG RD 1 Applicant/Agent: Robbins, Ty UMW/ Work Description: Wall sign - Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A- Board: No Sign Dimensions: 1.5'x12'10" Total Sign Area: 19.24 Wall Area: 2036 Wall Face (Direction): West Sign Height: 14 ft. Projection From Wall: 4 in. Illumination: Internal Materials: Aluminum /acrylic Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $165.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: Permittee Signature: it/ / , / - 4.4t _ir CITY OF TIGARD SIGN PERMIT Permit #: SGN2012 -00078 COMMUNITY DEVELOPMENT Date Issued: 05/11/2012 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2421 Parcel: /3 I, 5 !O / 6° 3 ' Jurisdiction: g OLVA Name of Business: Red Lobster L Business Address: i 1733 0 4 W bra 7 Applicant/Agent: 7 / 1 9 K 3 Work Description: Wall sign - ______- Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A- Board: No Sign Dimensions: 1.5'x12'10" Total Sign Area: 19.24 Wall Area: 2036 Wall Face (Direction): West Sign Height: 14 ft. Projection From Wall: 4 in. Illumination: Internal Materials: Aluminum /acrylic Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $165.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: . Permittee Signature: - ' ' CITY OF TIGARD RECEIPT 2 : 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 TIGARD Receipt Number: 186695 - 05/11/2012 CASE NO. FEE DESCRIPTION REVENUE ACCOUNT NUMBER PAID SGN2012 -00078 Sign Permit 100 - 0000 -43115 $144.00 SGN2012 -00078 Sign Permit - LRP 100 - 0000 -43117 $21.00 Total: $165.00 PAYMENT METHOD CHECK # CC AUTH. CODE ACCT ID CASHIER ID RECEIPT DATE RECEIPT AMT Check 279631 HWATKINS 05/11/2012 $165.00 Payor: North American Signs, Inc. Total Payments: $165.00 Balance Due: $0.00 Page 1 of 1 I N City of Tigard Sign Permit Application TIGARD Application GENERAL INFORMATION Name of Development /Project Site Red Lobster FOR STAFF USE ONLY Address/ Street Address Permit No.: `2 C�✓v t / 2- _CA' Location 10330 SW Greenburg Rd Approved By: / Suite/Bldg. # City/State Zip D J 4/ I� // Z Tigard, OR 97223 Name Receipt #: / &I Property Knickerbocker Properties, Inc. Map /TL #: / /35 0/bd Owner Mailing Address Suite Zoning. Li g 235 Montgomery St 16th Floor Allowable Total Area: / ' 9 '12 City/State Zip Phone San Francisco, CA 94104 503- 412 -4800 Tenant or Name Electrical Permit Required? 'Yes El Business Red Lobster Building Permit Required? ❑ Yes Mr No Name Rev. 7/1/11 Vancouver Sign Group is \ cumin \ masters \land use applications \ sign permit app.doc Sign Contractor Mailing Address Suite 2600 NE Andresen Rd 50 City /State Zip Phone REQUIRED SUBMITTAL ELEMENTS Vancouver, WA 98661 3 6 0 - 6 9 3 - 4 7 7 3 (Note: applications will nsd be accepted Oregon Const. Cont. Board License # Exp. Date without the required submittal elements) 63951 01 / 2 4 / 2 014 ❑ Completed Application Form Proposed ® Permanent ❑ Freestanding ❑ Freeway ❑ 2 copies of site /plot plan, drawn to scale Sign ❑ Temporary ❑ Roof ❑ Electronic (3 copies, if a building permit is required) (Check all that l © Wall El Other apply) t /2 size requirement: 8" x 11 ", or 11" x 17" ❑ 2 copies of elevations, drawn to scale p New sign? ❑ Alter to existing sign? (3 copies, if a building permit is required) Sign Dimensions:1 " x 12 ' - 9 15/16 " size requirement: 81/2" x 11 ", to 24" x 36" Total Sign Area (sq. ft.): 19 . 24 ❑ $165.00 Fee (Permanent sign, any size) Sign Data Total Wall Area (sq. ft.) . 94 ❑ $52.00 Fee (Temporary sign, any type) 2036 (Complete all Direction Wall Faces (circle one): items in this NOTES: section) N S E © NE NW SE SW Height to top of sign (feet): 151 -411 • Wall signs do not need to be drawn to scale, but Projection From Wall (inches): 4 " must include dimensions of wall face and sign placement. Materials: aluminum /acrylic • Wall signs do not require site /plot plans. Will sign have illumination? © Yes ❑ No • Freestanding signs over 6 ft. required a building Type: © Internal ❑ External permit. Are there any existing freestanding or wall signs at this location, including wall signs that overlap a tenant space? © Yes El No If "yes ", a list or diagram of all sign dimensions and square (OVER FOR SIGNATURES) footage must also be submitted. see sign packet for this info City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 718 -2421 I www.tigard - or.gov I Page 1 of 2 APPLICANTS: To consider an application complete, you will need to submit ALL of the REQUIRED SUBMITTAL ELEMENTS as described on the front of this application in the "Required Submittal Elements" box. NOTE: Person specified as "Applicant" shall be designated "Permittee" and shall provide financial assurance for work. * When the owner and the applicant are different people, the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s) must sign this application in the space provided on the back of this form or submit a written authorization with this application BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. ♦ All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted herewith, are true, and the applicants so acknowledge that any permit issued, based on this application, and may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application, including the policies and criteria, and understands the requirements for approving and denying the application. I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each owner of the subject property are required. p licant Signature Date Signature of Owner /Agent Date Ty Robbins 574 - 232 - 4474 Contact Person Name Phone No. City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 639 -4171 I www.tigard - or.gov I Page 2 of 2 .._ RECEIVED SITE ENHANCEMENT SERVICES, INC. 't. MAY 1 12012 CITY OF TIGARD PLANNING /ENGINEERING We, Darden Restaurants (GMRI, Inc.), hereby authorize Site Enhancement Services, acting as agent for Darden Restaurants (GMRI, Inc.), to proceed with the sign permit request for Red Lobster located at 10330 SW Greenburg Rd., Tigard, OR 97223. We have reviewed the proposed sign changes and authorize Site Enhancement Services to move forward with the sign permit process and any /all issues regarding signage. Corporate Representative's Name: Randy Calvanelli Representative's Signature: C Company Name: Darden Restaurants (GMRI, Inc.) 1000 Darden Center Drive Orlando FL 32837 Phone Number: 407.458.8109 Position: Design Project Manager Date: cl q It 2- TV/foregoing in tr ment was ackgowledg j; before m is 7'tay of l! , 2O 18y ���2� ( A/ - - / who is personal) known to me or who has produced as identification. Signature o Notary Public M,Y , �r� ;� KELLY SOLOMON :4 MY COMMISSION # EE 171433 W. % EXPIRES: February 20, 2016 ''tiff, '' Bonded Thru Notary Public Undennifers ■IIMP■ 6001 NIM"I'% PARKWAY, SOUTH BEND, INDIANA 46628 TEl,. 1.800.599.8121 FAX 574.237.6166 Existing: 14" x 7' - Awning Letters: 8.17 SF each (Qty 2) Site Plan o Proposed: 3'-4" x 7' - Critter: 23.89 SF Store #0457 O Proposed: 18" x 12' -9 15/16" Channel Letters: 19.24 SF co Existing: 36" x 18' -0" Channel Letters on Raceway: 54 SF (with 17 SF Critter) _.,... , ..._ _ . Proposed: 30" x 21' -3 13/16" Channel Letters: 53.29 SF r I. . . Existing: 3' -8 3/4" x 8' -5" Monument at 7' -4" OAH: 31.39 SF 1 / i 'id , o ill i '' Proposed: 3' -0' /2" x 8' -4" Monument at 6 -5 OAH: 25.35 SF •; ■ 2 *III Sir Existing: 1' -10" x1 Parking Sign at 7' - OAH: 1.83 SF ' ✓� sh,n 4lo Ci Proposed: Replacement Logo on Parking Sign: 1.83 SF 0 r .,� a 1. 1 ., •••....._• - / - - 1 --, •I ,... _. ........... \,4 A , -, . , /* B _ _ - --- ,,.-- ,, . D , , r- S,, '':','-'--..„ iv A "/ / . _....... 34 - 1.......410.4... 1111twt ,,, .. ,.. S .: , ? f/�; -1i f ' - ' E 1 \ \ .\ \ \ \IkV\ \ • Vitt . - ark sri' r r .1 i . s�. 1 or SES ;` Page 2 of 12 Existing: None --,14- , ,� •_ r ' T : 'q • Left Elevation -it' ' 4 Store #0457 c _ CITY OF TIGARD 1 tH , - # - --1� __ � i / APPro . � — "'A Conditionally Approved .................................. . ... (//j "� . ,__ For only vec the woryc ) -- = PERMIT NO. S desc_ ribed in: ' 07 6 See Letter to: Follow.._.. . �Ja Jot; Addre Attar _ . .. _ r Gi ) By: Date: // 82'-3 1/4° • _..._ 2T -3" .rrr.rrrr......._ ....rirrrrrrrrrrrrrrrrrr..._ ..r.._ • — -2 9/16' T -2 9/16" ..... ... ........iuqu p.. I■ ■III■■ ■■III■ ■■IIi� I .rrrrrrrrrrrrr..r.. ...14.... 111111111111111111111MOMMI, -•ier'''W;;;;;,.. - .41111111111111111111111111111111111.i 0 u■ lu.fi il n.l. . , lY t1 �(fixivr�ariiixrrx/A { i 4 8 4 e r r ■ , I UU I UUI I III I .I• I : °iti : _.�■ — Ii nil �„ ` -�� _ � ►�•,Il ►���I����IIL�.�I�� sa::� b. __ to S a vun .. uin = = ,S - ._ . x►i . 1►\rrrr.rr =IrOrrrrOur - -. ■.■. ■ --=. - -- � � — ° N CD u.�urrru�- aunn.::: ;Si r.. 17.7 1..l .-I �!n .vnUeq re uun ° o rn Ill NI 7N I ■ Ili ■ ' 7R 1:9:11:9:::p m ni rrr rrrlrrr O FIt1■ a■ .., '�� riii... ill! ... . .. I t I 7 I 54 : r1 rrrrr ■ ■ • • . • ■ okesougavalw oa o I++ �. Fa a r+ e.r.3 ter+ ll • I Scale: 1/16°=1' 12' -9 15/16" . ► /n , ' ,.rte_ 3'-9'/z" 8'-2 5/8.. { <u.re R d # . . • 1 1 . / ;°--__ ........4- ° • r D , d r 1 • 18" Channel Letters (Internally LED Illuminated Channel Letters) ` Utilized Square Footage: 19.24 ' Scale: 3/8"=1' a i ,... . i ./, ' : /4 /\ \\,\ \ \ \ \ \.\ \ \\:, \?, \ \ \,. . 1 s� Ph: 1. 800.599.7696 Fax: 1 . 574 . zs� .6166 www.s reenhancemertsaNrces.cocn Page 4 of 12 RL- SIG -1 BRM -PPCL -LED COLOR KEY (WHITE)-WHITE CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL 12' -9- 15/16" SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT ELECTRICAL REQUIREMENTS SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. 1 ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 Fl) TO BE BY CERTIFIED ELECTRICIAN: I T L:: Total: 1.7 Amps A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). sTED B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. 1 ' -6" C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D �1 120V 20A C eq'd D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. SIGNS j �1X°1NG MID NE R LLh "N° s NOT BE SHARED MN OTHER tows Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). RL- SIG -18RM -PPCL -LED SQ. FT. = 19.1 2. Delays and additional costs. SCALE: 1/2" TO 1 ' -0" Notes: Certain electrical components of signs will fail prematurely if signs are not shut -ofl for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Ceti that will automaticatiy shut -off the sign for a period of time, each day. Failure to do so wil cause damage to the electrical components of the sign and will void the warranty. Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation GENERAL SPECIFICATIOiJS SPECIAL NOTES ' with Federal Heath Sign Co. will void the warranty. INSTALLER IS RESPONSIBLE FOR: CHANNEL LETTERS: CHANNEL LETTERS (REMOTE) CONSTRUCTED OF ALUM LETTER BACKS BUILDING FASCIA TO BE HARDI -PLANK CEDAR SHAKE SIMULATION • PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, W/ ALUMINUM RETURNS TO BE EXTERIOR PRECOAT MATTE BLACK INTERIOR WHITE, SO IT WILL BE UNEVEN SURFACE. ADJUST LETTERS TO WHERE THE ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. .063" ALUM BACKS W/ 1" BLACK TRIM CAP ON A .177 FACES ARE ALL ON THE SAME PLANE. • PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. .040" RETURNS # 2447 WHITE ACRYLIC FACE W/ REMOTE POWER SUPPLIES, W/ L.E.D WHITE ILLUMINATION. AND TO USE SILICONE CAULK FOR ALL PENETRATIONS. • SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS.. Tetra r L ED 5 stem MATERIAL ESTIMATE . • St: 012297 - 01 ,. 4" Whoa Pairweim "•• SPECIAL INSTRUCTORS MAO ProOsu!«• 7 • ■ . O.: a -. ( wrr€wfMtE RL•S1C.10RIILPPCL -t1O 0 . `—"^ UST HARDY PLANK FASCIA MIN1414 PLYWOOD BACKING ,. SUPS1140 a i 2 X 4 WOOD STUD WALLS ' Pot Supph - • • 110 — II �_ Ins a DRYWALL( WHERE APPLICABLE) ', ,, 18" @ "R" St** WV, WO w Pt lid Cap uw rE.oao+t +a as L.E.D. POWER SUPPLIES III t � R I ) - - 4, r�.. . ,4, E »T�hh.wwa w T ..�,... .r.__. ' IN UL. TRANSFORMER BOXES „�sau� •s<,ahcw►r � � CODE COMPLIANT ELECTRICAL � J _ r, HOUSINGS &WIRING METHODS • ' L f ,�,. . 177 ACRYLIC FACE — ' I #24 47 WHITE 111 111111 0r . , CUT OFF SWITCH (LOCKABLE) �I ` TOGGLE BOLT OR OTHERS AS PER MUNICIPALITIES REQUIREMENTS ! RL -S1G• 18RM- PPCL -LED ' W/ SILICONE @ EACH PENETRATION I " OPINE Nash C+ehYrlo larhtivalw ToWI *V,} amid I Toot Miells lapelpapi Irr iwMr REMOTE FACE or BACKLIT 1 7 Amps 123.6 Watts A 10 Sq Ft 30 16 Watts/Sq Ft G.E. WHITE MA TS I! L . E .D.'s AS PER LAYOUTS . , t.411. 11411/0111C q MO K? C1 C MLn .w r.na! le 411 :aws ".I+ =away° u ssax.r .. Ns .n,.. a rsAtt.r ' . , -.. 11,1 .li• 4111,--5 r. (.841,04 j IIIIL , r ♦.r'.1e,. �.•rd.[ ... .: - »M r "r)IN M.y +'Vi ". !�/ . try. A. - ap.<4 .Y 1lyk r9 t} .+.7 -'Fi Y t+ i —iT BLACK 1" TRIM CAP UD 11 00U4 RK.V41001 AOC 71.00Mtv a Y/Y#pM010111 aso p •..r .. ° ... 1 , , .1,.. , >... ./ *so-. =. ■ w- ...+*.. 1 ., «... WEEP HOLES 2 PER LETTER • -- W/ WEEP HOLE COVERS *.• -; - w •� -• SUSPENDED CEILING Tit A. ,,Kr t4 . „ �, (WHERE APPLICABLE) Tetra • LED Systems ) Lu m i n oti o n , N$ , � u a , .. , ,. ,,, Drwg #: 012297-01 Ra” SECTION DETAIL RL- SIG -18RM- PPCL -LED tk ]59 WI ar+r l SCALE: 1 -1/2" T01' -0" Page 9 of 12