Loading...
Specifications • • o?a� v /9 _ I., __,___ Sprinkler A %� -- I , N Upright or Pendent �' Automatic Sprinkler ' ��: A I. p ,r. r-4 I w,a[ rt , T � , Manufactured by: Central Sprinkler Company ` s 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 1 Product Technical ifiiDescription Data The Central Model A Upright or Model: A Pendent Automatic Sprinklers are Style: Upright or Pendent \ standard spray sprinklers with a / traditional appeal. They incorporate a Orifice Size K Factor(metnc Th rea d , f 1. unique center strut design. 3 /e (9.5 mm) 2.7 (38.9) 1 /2 " (15mm) N.P.T. ' The Model A Sprinklers are 7 /16" (11.1 mm) 4.2 (60.6) ' /2 ' (15mm) N.P.T. ' , intended for installation in accordance * (12.7 mm) 5.6 (80.8) 1 /2 ' (15 mm) N.P.T. ..,. _ ,-- with current NFPA 13 Standards. 17 /32 ' (13.5mm) 7.8 (112.5) 1 /2' (15mm) N.P.T. -" They are available in a wide variety of 11 /32' (13.5 mm) 8.1 (116.8) 3 /4" (20mm) N.P.T. orifice sizes, temperature ratings, '250 psi (17.3 bar) rating. See maximum working r rr rr finishes, and corrosion resistant pressures below. 3 / g � 7 / 1 / 1 � 2 coatings. Temp. Rating and Frame Arm Color: 17 " Operation: A fusible alloy is 165 °F /74 °C Uncolored or / 32 sealed into a bronze center strut by a 212 °F /100 °C White stainless steel ball. When the alloy 286 °F /141 °C Blue (9.5mm, 11.0mm, 12.7mm, melts at its rated temperature, the ball 13.5mm) is forced upward into the center strut, Approvals: U.L., U.L.C., 'F.M., M.E.A. releasing the two ejectors and (375- 75 -SA), V.D.S., LPCB (see Orifice operating the sprinkler. Unlike most tabular information on Page 3.) other sprinkler designs, the alloy is " Not FM Approved for 3/8° (9.5 mm) orifice Automatic not exposed to atmospheric ® 286 °F /141 °C conditions that could affect its proper Sprinkler functioning. It is also less susceptible Maximum Working Pressure: to mechanical damage since there 250 psi (17.3 bar) - U.L. & U.L.C., are no protruding elements, 1 /2" Orifice Only extending beyond the sprinkler frame. 175 psi (12.1 bar) - all other listing Pintle: on deflector for 3 /8", agencies 7 /16 ",and "/32" orifice by 1 /2 "N.P.T. Factory Hydro Test: 100% at 500 psi (34.5 bar) Length: 2 (65.1 mm) excluding Standard Finishes: brass, chrome pintle plated, painted (chrome is not V.D.S. Approved Width: 1 1 /2" (38.1 mm) frame arms and painted is U.L. only.) Weight: 4.2 oz. (119 grams) Coatings: wax, lead, or wax - over -lead (see tabular information on page 3.) For specific listing requirements see the appropriate information contained in this brochure. No. 1 -1.0 Old Cat. No. 2 -1.0 Cross Section Cross Section Model "A" Upright Sprinkler Model "A" Pendent Sprinkler --.0 1 5/16" (33.3mm) 1 1/2" Diameter (38.1 mm) ' L , lir / _ I 3/4" \� E _ (19.1mm) E I i \ 2 9/16" % / ii / //, 65.1mm ili co AIM or, up co ; ; (19.1mm) \'/ N I /40 •-- __ -- 1 1/2" (38.1mm) 1 " (25.4 Diameter Combination Sprinkler Wrench (Part #1106) Cross Section Model "A" Upright Sprinkler (Small Orifice with Pintle) 1 5/16" (33.3mm) 211C. , Dia eter (4.8mm) ii — A i` 7z t ir ■■■■■• • ; ` ' \ Universal Wrench (Part #1122) ' 1\i ' 3/4" Z22 E N. ui cra A A (19.1mm) ;MIIII I i Design Requirements - Standard Applications The Model A Upright and Pendent Sprinklers are intended for ..• 1 1/2° (38.1mm) I standard area coverages and standard flow and pressure requirements as specified in current NFPA 13 Standards. 2 1 U.L., *U.L.C. and * * MEA (N.Y.C.) Cal. No. 375 -75 -SA Listings Orifice Size and Style Temperature Rating ( °F) Corrosion- Resistant Coating 3 - - - 165(74.c) 212(1oo * * * * 286(1419c) lead, wax, wax- over -lead /e "(s.5mm) upright and pendent 7 /16 "(11.1mm) upright and pendent - - - 165(74.c) 212(foo * * ** 286(1419c) lead, wax, wax- over -lead - - - 165(74.c) 212(foo.c) * ** * 286(14190) lead, wax, wax- over -lead /2" (12.7mm) upright and pendent 17 /32 "(13.5mm) X' /2'(15mm) NPT upright and pendent - - - 165(74'c) 212(100 .c) * * ** 286(+41 C) lead, wax, wax- over -lead "/32 "(13.5mm) X 3 /4 "(2omm) NPT upright and pendent_ - - - 165(74 212(1oo * ** * 286(1419c) lead, wax, wax - over -lead • 286° temperature is not U.L.C. Approved with corrosion- resistant coatings. •• No corrosion - resistant coatings are Approved by MEA. ••• Lead only. •••• Listed as high temperature, wax coated for installation where maximum ambient ceiling temperature does not exceed 150 °F. F.M. Approvals Orifice Size and Style Temperature Rating ( °F) Coating 3 /6 ' (9.5mm) upright - - - 165(749c) 2120oo'c) - - - lead 3 /a" (9.5mm) upright - - - - - - 212(1oo'c) - - - wax - over -lead 3 /8 " (9.5mm) upright - - - - - - 212(1oo9c) - - - wax 1 /2" (12.7mm) upright and pendent - - - 165'7490 212(foo'c) 286(1419c) lead 1 /2" (12.7mm) upright and pendent - - - 165(74 212(1oo9c) - - - wax- over -lead 1 /2" (12.7mm) upright and pendent - - - 165(74 2120oo'c) 286(1419c) wax "/32 "(13.5mm) x 1 /2 "(15mm) NPT upright and pendent - - - 165(7490 212(1oo90 286(1419c) lead 17 /32 "(13.5mm) X '/2 "(15mm) NPT upright and pendent - - - - - - 2120oo'c) - - - wax - over -lead "/32 "(13.5mm) x' /2 "(15mm) NPT upright and pendent - - - - - - 2120oo90 286(1419c) wax 17 /32 "(13.5mm) X 3 /4 "(2omm) NPT upright and pendent - - - 165'74'c) 212(10o'c) 286 (1410 lead "/32 "(13.5mm) x 3 /4 "(20mm) NPT upright and pendent - - - - - - 212(1 .') - - - wax -over lead 17 /32 "(13.5mm) x 3 /4 "(2omm) NPT upright and pendent - - - - - - 2120oo•c) 286(141•c) wax LPCB Listings Orifice Size and Style Temperature Rating ( °F) Corrosion- Resistant Coating 1 /2 "(12.7 mm) upright and pendent - - - 165(749c) 212(foo'c) 286(1419c) - - - . "/32 "(13.5 mm) X 3 /4 "(2o mm) NPT upright and pendent - - - 165(74C) 212(foo'c) 286(141'c) - - - - V.D.S. Listings Orifice Size and Style Temperature Rating ( °F) Corrosion- Resistant Coating 3 /8 "(s.5 mm) pendent - - - 165(74 - - - - - - - - - '/2 "(12.7 mm) upright and pendent - - - 165(74.0 212(1oo'0 286(1419c) - - - "/32 "(13.5 mm) X 3 /4"(2omm) NPT upright and pendent - - - 165(74'C) 212(foo'c) 286(141'C) - - - 0 Installation Wet pipe systems must be Step 3. Hand tighten the sprinkler p rotected from freezing. Refer to the into the fitting. For upright sprinklers Central Bulletins on the Model A -1 use a Central Sprinkler Combination Dry Pendent Sprinklers for use in dry Wrench, and for pendent sprinklers pipe sprinkler installations. use a Central Sprinkler Universal All Central Model A Sprinklers Upon completion of the Wrench, to tighten the unit into the must be installed according to current installation, the system must be fitting. A leak -tight joint requires only NFPA 13 Standards. Deviations from tested per recognized standards. 7 to 14 ft.- lbs.(9.5 to 19.0 Nm) of torque; these requirements and standards or In the event of a thread leak, a tangential force of 14 to 28 Ibs.(62.3 - any alteration to the sprinkler itself remove the unit, apply new pipe joint to 124.5 N) delivered through a 6" (150 will void any warranty made by compound or tape, and reinstall. mm) handle will deliver adequate Central Sprinkler Company. In torque. Torque levels over 21 ft.- addition, installation must also meet Installation Sequence Ibs.(28.6 Nm) may distort the orifice local government provisions, codes seal, resulting in leakage. and standards as applicable. Step 1. The unit must be installed For exposed piping systems, the The system piping must be in the upright position for upright style sprinkler should be oriented so the properly sized to insure the minimum sprinklers, and in the pendent frame arms are parallel with the required flow rate at the sprinkler. position for pendent style sprinklers. branch line pipe. Check for the proper model, style, Step 2. Use only a non - hardening Caution: Special care must be taken orifice size, and temperature rating pipe joint compound or Teflon* tape. when installing with a CPVC piping prior to installation. Install sprinklers Apply only to the male threads. system. Sprinklers must be installed after the piping is in place to avoid after the CPVC manufacturer's mechanical damage; replace any recommended setting time for the damaged units. 'Teflon is a trademark of the DuPont Corp. primer and cement to ensure that no 3 G B - Q R (at) Quick Response Upright, Pendent, Rec. Pendent Sidewall & Rec. Sidewall . ' Glass Bulb Automatic Sprinklers_ Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 pli Product NFPA Standards. They are availvble in "/32" (13.5mm), 1 /2" (12.7mm), and 7 /16" (11.1mm) orifice sizes and 135 °F (57°C), 155 °F Description (68°C), 200 °F (93°C), and 250 °F (121 °C) o f o!'T ., s temperature ratings.The Model GB -QR & The Central Model GB -OR & GBLO -QR GBLO -QR Sprinklers are available in Brass, 5: • ' ' Automatic Sprinklers embrace the ultimate Chrome, or White and Black painted in advanced design features. They finishes. incorporate the latest in glass bulb Operation: The glass bulb capsule •s "''+ Lam:" technology, which result in a much smaller, operating mechanism contains a heat- ;_., - 1.: ,T._ ,.,; more attractive sprinkler. The operating sensitive liquid that expands upon mechanism consists of a liquid - filled 3 mm application of heat. Upon reaching the rated diameter frangible capsule that is only 20 temperature, the frangible capsule ruptures mm in length. thereby releasing the orifice seal. The L immiummein i j The Model GB -OR & GBLO -QR • sprinkler then discharges water in a pre - Automatic Sprinklers are intended for designed spray pattern to control or installation in accordance with current extinguish the fire. �x . ,, Technical Data Model & Orifice Temperature Approved Thread 1 empe Standard Deflector and Recessed Finishes • Approvals Size Rating t • Style K- Factor Escutcheon "NPT" -. ., t= 1 GBLO -QR mm 200°F/93°C Chrome, & 155 °F /68 °C ELO Brass, „/ Upright, u ( 13.5 I Recessed UL, cUL, 3/4° Pendent, & 8.0 (114 metric) 250 °F /116 °C Support Painted & FM (20 mm) Rec. Pendent Cup (12.7 ) , GB -OR 5.6 (80 metr c) 155 °F /68 °C Brass, UL, ULC, 1/2' ; Upright & & --- Chrome, & & MEA k I 200 °F /93 °C (15 mm) Pendent / 11.0 mm Painted 466 -92 -E Vol.111 ,e ( ) 250 °F /116 °C ( ) )• 4.2 (60 metric) : ! ir 135 °F /57 °C Brass, i i GB -OR Chrome, & 1111 /' (12.7 mm) 155 °F /68 °C 1/2° Upright & 5.6 (80 metric) 200 °F /93 °C °Painted FM (15 mm) Pendent 250 °F /116 °C Pendent Only' . - 1 '/Z (12.7 mm) q GB -OR 5.6 (80 metric) 135 °F /57 °C GB Res. / OR Brass, UL, ULC, 1/2° Recessed & 155 °F /68 °C Recessed Chrome, & & MEA (15 mm) Pendent '/ (11.0 mm) 200 °F /93 °C Support Cup Painted (466 -92 -E Vol.III) 4.2 (60 metric) 1 7/32' • 5 mm). GB -QR , 135°F/57°C Brass, Recessed ! (12.7 mm) 155 °F /68 °C Vented Rec. Chrome, & FM 1/2" 5.6 (80 metric) Support Cup Pendent 200 °F /93 °C Painted 1/2112.7 mm) & GB -OR — 135 °F /57 °C GB Res. / QR Brass, UL, ULC, V; (12.7 mm) 1/2' Sidewall & 155 °F /68 °C Recessed Chrome, & & MEA Rec. Sidewall 5.6 (80 metric) Support Cup Painted (15 mm) 200 °F /93 °C Su �� pp (466.92 -E Vol.111) 7/1 (1 1.O mm) GB -QR "' '/, (12.7 mm) 135 F/57° Brass & 1/2° Sidewall 5.6 (80 metric) 155 °F /68 °C Chrome FM (15 mm) 200 °F /93 °C Orifice • Maximum working pressure: 175 psi (12.1 bar). The 1/2 °(12.7 mm) orifice Upright, Pendent and Rec. Pend. is UL and ULC listed with a maximum working pressure of 250 psi (17.3 bar). Available upon Aut omat i c special request. • Factory Hydro Test: 100% 0 500 psi (34.5 bar) ' Painted Versions are UL, cUL, and ULC listed as 'Corrosion Resistant" sprinklers. Sprinkler • Factory Mutual Approval for Rec. Pendent sprinklers requires the use of a vented support cup. Part #3071 Chrome, #3072 Brass, and #3073 White. "' The GB -OR Sidewall and Recessed Sidewall is UL and ULC listed for Light and Ordinary Hazard Occupancies. Factory Mutual approval is limited to Light Hazard Occupancies only. No. 1 - 7.0 Old Cat. No. 3 -10.0 GBLO-QR 17/32" GBLO -OR 17/32" • Recessed Pendent Upright &Pendent 1 I 1 I 1 1 3/8" 1 2 3/4 "(50.8mm) Min. I (35 mm) 1 2 1 /4 "(57.2mm) Max. I SUPPORT 1 I C UP I i _ Model ELO ; 'FACE OF REDUCING' Rec. Escutcheon I ; ; ____ COUP LING__ _ 1 2 1/8° (54 mm) I , �,,� II CENTRAL , 1�_� 11 (19 mm) Max. _ ipir --- " . "" ----- � ---- % l 3/8" (9.5 mm) Min. it 11 FINISHED ' CEILING LINE 1VW-N30 , ■ 2 1/8" (54 mm) nuon11onuuuu IF 3 1/4" tir . (83 mm) 1 3/16" j (30 mm) '"III GB -OR 7/16" & 1/2" GB -OR 7/16" & 1/2" Upright &Pendent Recessed Pendent 1 1/16" Pintle indicates (27 mm) 7/16" (11 mm) s mall orifice sprinkler �, 2" (50 mm) Min. / ' SUPPORT 2 1/4" (57 mm) Max. 1 , CUP 1 1 Model GB Res. /QR FACE OF REDUCING ■ I Rec. Escutcheon _; ;, COUPLING 1/2" /2" (50 mm ) � li l , ��� , 4 3/4" (19 mm) Max., L ��:�__ , 3/8" (9.5 mm) Min. _ � �� 1� � � ■ t FINISHED CEILING LINE = Lill 1/2" (50 mm) f 1 Pintle indicates 7/16" (11 mm) small orifice sprinkler ■ 2 7/8" -- (73.0 mm) 'Support cup for Model GB OR with FM Approval has slots in the face, Pintle indicates 741/16" the standard U.L. version does not. 7/16" (11 mm) 27 mm) small orifice sprinkler 2 1 • • GB -OR 1/2" Recessed Sidewall Design FACE OF 3/4' (19.1 mm) Data _ REDUCING I. MAX. ,J FINISHED COUPLING 3/8' (9.5 mm) I WALL LINE MIN. — — The Model GB -QR & GBLO -QR Automatic Sprinklers are intended for SUPPORT CUP standard area coverages and flow and pressure requirements as specified in ___ current NFPA Standards for quick i response sprinklers. - - - -1 1 • 1 1 • 2 7/8' • (73.Omm) Installation 1 13/16' (46.0 mm) All Central Model GB -QR & GBLO -QR l 011 Automatic Sprinklers must be installed - -- J \ according to current NFPA Standards. Deviations from these requirements and _ standards or any alteration to the / /I // 1 sprinkler itself will void any warranty . • / - - 25/16' (58.7 mm) - made by Central Sprinkler Company. In GB ResJOR RECESSED addition, installation must also meet local ESCUTCHEON government provisions, codes, and 1 standards as applicable. 3/6 (s.smment m) .i The system piping must be properly Adiusl Note: Central's Model 65 or 401 escutcheon may be used. When using Central's Model 65 sized to ensure the minimum required escutcheon, face of R.C. to protrude 1/8" ± 1/16" beyond finished wall line. flow rate at the sprinkler. Check for the proper model, style, orifice size, and temperature rating prior to installation. Install sprinklers after the Combination Wrench (Part #1106) piping is in place to avoid mechanical (For 7/16" & 1/2" Upright Sprinklers) GB Sprinkler Wrench (Part #1099) damage; replace any damaged units. • ELO /ESLO Combination (Part #1073) (For 7/16" & 1/2" Pendent & Sidewall Wet pipe systems must be protected from (For 17/32" Upright Sprinklers) Sprinklers) freezing. Upon completion of the installation, the system must be tested per recognized -. standards. i3CV , . In the event of a thread leak, remove the unit, apply new pipe joint compound or tape, and reinstall. Installation Sequence Note: Use Appropriate wrench when ELO /ESLO Offset (Part #1093) installing the Upright, Pendent, and (For 17/32" Pendent Sprinklers) Sidewall Sprinklers. • Step 1. The unit must be installed in the A upright position for the upright style sprinklers or in the pendent position for pendent sprinklers, and in the sidewall I' position for sidewall sprinklers. Step 2. Use only a non - hardening pipe _ joint compound or Teflon* tape. Apply only to male threads. Step 3. Install the sprinkler according to the dimensions shown in the installation diagrams on pages two and three of this technical bulletin. For recessed . Teflon is a trademark of the DuPont Corp. 3 CENTRAL • • '_ - • • • ESLO S. 1 „ 4 , 0 2 0 --,-6 -6,--,..,". 7 Extended Coverage Ordinary Hazard Very Extra Large Orifice o P T ■ Upr Pendent and Recessed Pendent Glass Bulb Automatic Sprinkler Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 r 1 Product Technical 0 EM Description n Data - The Central Model ESLO Very Extra Large Model: ESLO i ' Orifice Upright, Pendent and Recessed Pendent Style: Upright, Pendent & Recessed rar* Glass Bulb Automatic Sprinklers are specifically Pendent designed for Extended Coverage Ordinary Escutcheon: Model ELO (2- piece) �. - tlf. Hazard for all Groups as defined by NFPA 13. Recessed i- The ESLO is Listed for an 18" (457.2 mm) `� ` -- commodity clearance from the deflector, as Escutcheon Part #'s: standard sprinklers are per NFPA 13. 850 - Brush Brass 853 - White { --~�'� The ESLO pendent is the first extended 851 - Bright Chrome 848 - Off White coverage ordinary hazard sprinkler ever Approved 852 - Bright Brass 849 - Black by Factory Mutual. As with any project that Note: In the recessed position, only the requires Factory Mutual Approval, always consult Model ELO (2- piece) Recessed Escutcheon the F.M. Guidelines for their specific requirements. may be used. Substitution of other The ESLO provides the maximum in design flexibility as it has a minimum separation of only "recessed" escutcheons may impair the • 8' 0" (2.4 m) for upright and 9' 0° (2.7 m) for _ operating sensitivity and distribution pattern. _ pendent versions and is Listed for flows and Wrench ,C'- )1 pressures associated with 14' x 14' (4.3 x 4.3 m) Pendent Upright: Part #1073 ELO /ESLO/ and 16' x 16' (4.9x 4.9m), as well as 18' x 18' (55 ESFR Combination 1 x 5.5 m) and 20' x 20' (6.1 x 6.1 m) spacing. Recessed Pendent: Part #1093 ESLO Offset They are intended for use, as all extended Orifice Size: 0.70" (17.8 mm) (VELO) coverage sprinklers are, with hydraulically _ K- Factor: 14.5 (207.35 metric) designed systems and using the flows and _ Thread Size: 3 / <" N.P.T. (20 mm) pressures as shown in this brochure. For the Temperature Rating: 155 °F /68 °C Red purpose of determining the correct flow and 200 °F /93 °C Green pressure to use in the hydraulic calculations, all spacing is rounded up to the next higher 250 °F /121 °C Blue category. For example, 17-6° x 15' -0" (5.3x Installation Limitations: Extended 4.6 m) spacing would be calculated at the Listed • Unobstructed or non - combustible 18' x 18' (5.5 x 5.5 m) flow and pressure. obstructed construction. Coverage The advantage of the ESLO is the ability to • Minimum hydraulic design area of 5 cover large areas, up to 400 square feet (37.2 m heads or 1500 sq. ft. (139.5 m2), Ordinary pressures that compare to '/2" (15 mm) whichever is greater (UL only). standard sprinklers spaced at their maximum of • Minimum spacing between upright sprink- 130 square feet (12.09 m For example, the lers is 8' -0" (2.4 m). Minimum spacing Hazard Glass ESLO can cover 18' x 18' (5.5 x 5.5 m) spacing or between pendent and recessed pendent 324 square feet (30.1 m with less pressure than sprinklers is 9' -0 (2.7 m) (UL only). is required with 1/22 (15 mm) sprinklers at 130 • Maximum ceiling slope is 2 per foot Bulb Sprinkler square feet (12.09m2). (20.0 vs. 21.3 psi (0.7vs. (50.8 mm /m) per NFPA 13. 1.5 bar)) • Web member of open web trusses must Standard Finishes: The Model ESLO Sprinkler incorporates a not exceed 1" (25.4 mm) maximum Sprinkler: brass or chrome plated specially designed deflector that provides a much greater area of coverage than standard dimension. Decorative Finishes: white or black painted commercial sprinklers. The two (2) piece Approvals: U.L., c -UL. "F.M., Corrosion- Resistant Coatings: White or black recessed escutcheon assembly provides for W **M.E.A. (466 -92 -E Vol. II) painted (U.L. only) (19.1 mm) of field adjustment. • Pendent only, not recessed pendent or Coatings:wax, lead, wax - over -lead (FM only) Operation: The glass bulb capsule operating upright. Escutcheon: brass, chrome plated, white or mechanism contains a heat- sensitive liquid that "" Pendent and Recessed Pendent only. black painted expands upon application of heat. At the rated Maximum Working Pressure: 175 psi (12.1 bar) Length: 2W (70 cm) temperature, the frangible capsule ruptures, Factory Hydro Test: 100% at 500 psi (34.5 bar) Width: 1'/2" (3.80 cm) thereby releasing the orifice seal. The sprinkler Weight: 4.2 oz. (120 grams) then discharges water in a pre- designed spray No. 2 -2.0 pattern to control the fire. Old Cat. No. 3-4.0 Figure 1 Figure 2 ESLO Extended Coverage Ordinary Hazard ESLO Extended Coverage Ordinary Hazard Upright Pendent • 1-1 1/2" (38.1 mm) ► liZilirM% all••■••■••■11WIL O M. AN TALLN33 2 3/4° 2 3/4" (69.9 mm) (69.9 mm) III CENTRAL 111 1 r i e , • I � 11/2 1 ,1 •I (3 mm) Dia. • Consult the Factory Mutual Guidelines for Installation specific Factory Mutual requirements if Factory Mutual Approval is required. All Central Model ESLO Upright, Pendent and Recessed Pendent Figure 3 Automatic Sprinklers must be installed ESLO Extended Coverage Ordinary Hazard Recessed Pendent Standard and these installation in- structions. Deviations from these re- 1•x3/4' (25 mm x 20 mm) quirements and standards or any Reducing Coupling alteration to the sprinkler itself will ' i Face o f 3/e° (9.5 mm) Min. void any warranty made by Central \ Reducing 3!4• (20 mm) Nominal Sprinkler Company. In addition, Coupling I i 1 1I8° (2e.6 mm) Max. installation must also meet local gov- - 111... 1----- - i ernment provisions, codes, and stan- dards as applicable. . , .1 i 1== I 4 1 — The system piping must be properly ivd1N3� I sized to ensure the minimum required ' Finished flow rate at the sprinkler. Check for (' Ceiling Line the proper model, style, orifice size, and temperature rating prior to Model ELO (2- piece) installation. Install sprinklers after the Recessed Escutcheon piping is in place to avoid mechanical ill damage; replace any damaged units. Wet pipe systems must be protected from freezing. Upon completion of the installation, the system must be tested per z ,ra• (s�.2 mm) Dia. Min. recognized standards. 2 3/4• (69.9 mm) Dia. Max. In the event of a thread leak, 31/a• (82.6 mm) Diameter remove the unit, apply new pipe joint compound or tape, and reinstall. Note: Centrals Model 65 or 401 escutcheon may be used. When using Central's Model 65 escutcheon, the face of the R.C. is to protrude 1/8't1/16' beyond the finished ceiling line. (Continued on back page) 2 • Design • Data Design Requirements - Commercial Extended Coverage Applications Ordinary Hazard, Density 0.15 GPM/ft - NFPA 13 1991 and later Temperature Rating 155 °F /68 °C, 200 °F /93 °C and 250 °F /121 °C Maximum Minimum Design Minimum Design Spacing Between Sprinklers Location From Flow per Sprinkler Pressure per Sprinkler Any Wall gpm (Lpm) psi (bar) 14 x 14 feet (196 sq. ft.) /4.3 x 4.3 m (18.2 m 7 feet (2.1 m) 38.4 (145.5) 7.0 (0.5) 16 x 16 feet (256 sq. ft.) /4.9 x 4.9 m (23.8 m 8 feet (2.4 m) 38.4 (145.5) 7.0 (0.5) 18 x 18 feet (324 sq. ft.) /5.5 x 5.5 m (30.1 m 9feet 48.6 (184.2) 11.2 (0.8) 20 x 20 feet (400 sq. ft.) /6.1 x 6.1 m (37.2 m 10 feet (3.0 m) 60.0 (227.4) 17.1 (1.2) Design Requirements - Commercial Extended Coverage Applications Ordinary Hazard, Density 0.16 GPM/ft NFPA 13 1989 and earlier Temperature Rating 155 °F /68 °C, 200 °F /93 °C and 250 °F /121 °C Maximum Minimum Design Minimum Design Spacing Between Sprinklers Location From Flow per Sprinkler Pressure per Sprinkler Any Wall gpm (Lpm) psi (bar) 14 x 14 feet (196 sq. ft.) /4.3 x 4.3 m (18.2 m 7 feet (2.1m) 38.4 (145.5) 7.0 (0.5) 16 x 16 feet (256 sq. ft.) /4.9 x 4.9 m (23.8 m 8feet (2.4m) 41.0 (155.4) 8.0 (0.6) 18 x 18 feet (324 sq. ft.) /5.5 x 5.5 m (30.1 m 9 feet (2.7m) 51.8 (196.3) 12.8 (0.9) 20 x 20 feet (400 sq. ft.) /6.1 x 6.1 m (37.2 m 10 feet (3.0 m) 64.0 (242.6) 19.5 (1.3) Design Requirements - Commercial Extended Coverage Applications Ordinary Hazard, Density 0.19 GPM/ft - NFPA 13 1989 and earlier Temperature Rating 155 °F /68 °C, 200 °F /93 °C and 250 °F /121 °C Maximum Minimum Design Minimum Design Spacing Between Sprinklers Location From Flow per Sprinkler Pressure per Sprinkler Any Wall gpm (Lpm) psi (bar) 14x14 feet (196 sq. ft.) /4.3x4.3m(18.2m 2 ) 7 feet (2.1 m) 38.4 (145.5) 7.0 (0.5) 16 x 16 feet (256 sq. ft.) /4.9 x 4.9 m (23.8 m 8 feet (2.4 m) 48.6 (184.2) 11.2 (0.8) 18 x 18 feet (324 sq. ft.) /5.5 x 5.5 m (30.1 m 9 feet (2.7m) 61.6 (233.5) 18.0 (1.2) 20 x 20 feet (400 sq. ft.) /6.1 x 6.1 m (37.2 m 10 feet (3.Om) 76.0 (288.0) 27.5 (1.9) Design Requirements - Commercial Extended Coverage Applications Ordinary Hazard, Density 0.20 GPM/ft - NFPA 13 1991 and later Temperature Rating 155 °F /68 °C, 200 °F /93 °C and 250 °F /121 °C Maximum Minimum Design Minimum Design Spacing Between Sprinklers Location From Flow per Sprinkler Pressure per Sprinkler Any Wall gpm (Lpm) psi (bar) 14 x 14 feet (196 sq. ft.) /4.3 x 4.3 m (18.2 m 7 feet (2.1 m) 39.2 (148.6) 7.3 (0.5) 16 x 16 feet (256 sq. ft.) /4.9 x 4.9 m (23.8 m 8 feet (2.4 m) 51.2 (194.0) 12.5 (0.9) 18 x 18 feet (324 sq. ft.) /5.5 x 5.5 m (30.1 m 9 feet (2.7 m) 64.8 (245.6) 20.0 (1.4) 20 x 20 feet (400 sq. ft.) /6.1 x 6.1 m (37.2 m 10 feet (3.0 m) 80.0 (303.2) 30.4 (2.1) Design Requirements - Commercial Extended Coverage Applications • Ordinary Hazard, Density 0.21 GPM/ft NFPA 131989 and earlier Temperature Rating 155 °F /68 °C, 200 °F /93 °C and 250 °F /121 °C Maximum Minimum Design Minimum Design Spacing Between Sprinklers Location From Flow per Sprinkler Pressure per Sprinkler Any Wall gpm (Lpm) psi (bar) 14 x 14 feet (196 sq. ft.) /4.3 x 4.3 m (18.2 m 7 feet (2.1 m) 41.2 (156.1) 8.1 (0.6) 16 x 16 feet (256 sq. ft.) /4.9 x 4.9 m (23.8 m 8feet (2.4m) 53.8 (203.9) 13.8 (1.0) 18 x 18 feet (324 sq. ft.) /5.5 x 5.5 m (30.1 m 9 feet (2.7 m) 68.0 (257.7) 22.0 (1.5) 20 x 20 feet (400 sq. ft.) /6.1 x 6.1 m (37.2 m 10 feet (3.0 m) 84.0 (318.3) 33.6 (2.3) Caution: Minimum spacing between upright sprinklers is 8' -0" (2.4 m). Minimum spacing between pendent or recessed pendent sprinklers is 9' -O" (2.7 m). 3 r Installation Sequence It is advisable to have sprinkler sys- ate but were subjected to corrosive • tems inspected regularly by a qualified elements of combustion or excessive Step 1. For Pendent and Recessed inspection service. Length of time be- temperatures should be inspected, Pendent sprinklers, the face of the tween such inspections can vary due and replaced if need be. The Author- , sprinkler fitting should be installed a to accessibility, ambient atmosphere, ity Having Jurisdiction will detail mini - nominal 3 /4 " (± " ) (19.1 mm ± 9.5 mm) water supply, and site activity. mum replacement requirements and behind the ceiling line. Adjustments Do not attempt to reassemble or regulations. are made via the push -on escutcheon. otherwise reuse a sprinkler that has Step 2. Use only a non - hardening operated. Replace any sprinkler exhib- Guarantee: Central Sprinkler Corn- pipe joint compound or Teflon* tape. iting corrosion or damage; always use pany will repair and/or replace any Apply only to the male threads. new sprinklers of the same type and products found to be defective in ma- temperature rating as replacements. terial or workmanship within a period Step 3. Hand tighten the sprinkler Because the discharge pattern is of one year from the date of shipment. into the fitting. Use a Central Sprin- critical to protection of life and prop- Please refer to the current Price List kler Wrench, to tighten the unit into erty, nothing should be hung or at- for further details of the warranty. the fitting. A leak -tight joint requires tached to the sprinkler unit that would only 7 to 14 ft. -lbs. (9.5 to 19.0 Nm) disrupt the pattern. Such obstructions of torque; a tangential force of 14 to must be removed. In the event that Ordering 28 lbs. (62.3 to 124.5 N) delivered construction has altered the original through a 6" (150 mm) handle will configuration, the system must be in- imp Information deliver adequate torque. Torque lev- vestigated and the protection level els over 21 ft. -lbs. (28.6 Nm) may maintained. Ordering Information: When placing distort the orifice seal, resulting in Do not attempt to replace sprinklers an order, indicate the full product leakage. without first removing the fire protec- name. Please specify the quantity, 'Teflon is a trademark of the DuPont Corp. tion system from service. Be certain model, style, orifice size, temperature to secure permission from all authori- rating, type of finish or coating, and Care & ties having jurisdiction, and notify all sprinkler wrench. personnel who may be affected during Maintenanc system shutdown. A fire watch during Availability and Service: Central maintenance periods is a wise pre- sprinklers, valves, accessories, and caution. other products are available through - Sprinklers must be handled care- To remove the system from service out the U.S. and Canada, and inter - fully. They must not be transported or mode, first refer to the system operat- nationally, through a network of Cen- stored where ambient temperature ing guide and valve instruction. Drain tral Sprinkler distribution centers. You may exceed 100 °F /38 °C. For best water and relieve pressure in the may write directly to Central Sprinkler results, store them in a dry, cool loca- pipes. Remove the existing unit and Company, or call (215) 362 -0700 for tion in the original shipping package. install the replacement, using only the the distributor nearest you. Do not install sprinklers that have special sprinkler wrench. Be certain been dropped or visibly damaged. to match model, style, orifice, and Patents: The ESLO Optima sprin- Sprinklers must never be painted, temperature rating. klers are protected under U.S. Patent coated, plated, or altered in any other A fire protection system that has No. 5,366,022. way from manufactured condition or been shut off after an activation they may not function properly. Any should be returned to service immedi- Conversion Table: sprinklers altered in such manner ately. Inspect the entire system for 1 inch = 25.400 mm must be replaced. damage and replace or repair as nec- 1 foot = 0.3048 m The owner is responsible for the essary. Sprinklers that did not oper- 1 pound = 0.4536 kg proper operating condition of all fire 1 foot pound = 1.36 Nm protection devices and accessories. 1 psi = 6.895 kpa The NFPA standard 25 entitled, • = 0.0689 bar "Inspection, Testing and Maintenance = 0.0703 kg/cm of Water -Based Fire Protection Sys- ■ 1 U.S. gallon = 3.785 dm3 tems ", contains guidelines and mini - ■01■■ = 3.785 liters mum maintenance requirements. Fur- thermore, the local Authority Having Conversions are approximate. Jurisdiction may have additional regu- EENTRAL lations and requirements for mainte- nance, testing, and inspection that -•■■- OPTIMATM is a registered trademark of must be obeyed. Central Sprinkler Company Central Sprinkler Company. 451 North Cannon Avenue, Lansdale, PA 19446 ©1998 Central Sprinkler Company PHONE (215) 362 -0700 Printed in U.S.A. FAX (215) 362 -5385 ESLO OH.2DC CENTRAL GB4, GB4 -FR 2 -98 TM R�yal Flush _ aft ,/- Concealed kc /PH:.-''T -----------4 i o ,,,, _____...somr„,:-.. Standard Response (GB4) - .. Quick Response (GB4 -FR) , - Automatic Sprinklers _ Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 fuses, resulting in the plate dropping away 1 �1 Product from the sprinkler. At this point, the � (12.7 mm) deflector drops down below the ceiling IL T Description exposing the glass bulb to the fires heat. Orifice The heat bursts the bulb resulting in a rapid expulsion of the sealing cap. Water The Central GB4 and GB4 -FR Royal can now flow in a pattern engineered to Adj � �t a b I e Flush Adjustable Concealed Sprink -lers meet the coverage requirements. are standard spray sprinklers that allow over' /2 "(12.7 mm) of adjustment with an Technical Concealed aesthetically pleasing cover plate design. The GB4 is a standard response sprinkler D using a 5mm glass bulb and the GB4 -FR Ceiling is a quick response sprinkler using a 3mm glass bulb. These sprinklers are perfect Model: GB4 or GB4 - for applications in light or ordinary hazard S p r i n k l e r at standard spacing for projects that Style: Concealed (adjustable) require UL, cUL, MEA and /or FM Listing Options: 'Clean Room Seal and Approvals. (Part #10908100) Standard Finishes: By adding the option of the clean • Clean Room Seal is U.L. & cUL Listed for GB4 only. It room seal, the GB4 can be used in areas is not Approved for GB4 -FR. Please reference Clean Sprinkler: brass where dust or air flow cannot be allowed Room Seal data sheet for more information. between the room and the area above the Cover Plate: brass, chrome plated, ceiling. This option is used extensively in Wrench: GB4 (Part #1075) or white painted, or custom "clean room" applications where the 1 „ painted h Orifice Size: (12.7 mm) integrity of the ceiling is critical. The Length: 21/2" to 3" (63.5 mm to 76.2 mm) Clean Room Seal is U.L. Listed for GB4 K - Factor: 5.6 (80.8 metric) only. It is NOT Listed for the GB4 -FR. Cover Plate: 3'/4" diameter (82.5 mm) See the clean room seal data sheet for Thread Size: /2 (15 mm) N.P.T diameter details. Approvals: U.L., cUL, 'F.M., Ceiling Opening: 2/2 ±/e (63.5 mm ± 3.2 mm) Inherent in the design is the capability M.E.A. (64 - - Vol. II) to compensate for ceiling heights w hi c h Adjustability: 1 /2" (12.7 mm) • FM Approval is for standard response only for vary with respect to the sprinkler system both light and ordinary hazard in accordance Weight: 6.6 oz. (187 grams) with ceiling piping. This significant feature allows the with FM guidelines. plate assembly Central GB4 and GB4 -FR sprinklers to seat flush with ceilings that can fluctuate Temperature Rating: Patents: Patent #4,014,388 other nearly '/2"(12.7 mm) in height. The 31/4" (82.5 155 °F /68 °C Sprinkler with - patents are pending. mm) diameter cover plate presents an 135 °F /57 °C Cover Plate unobstructed and aesthetic appearance. The thin cover plate projects a mere 3/1e" 200 °F /93.3 °C Sprinkler with (4.8 mm) below the ceiling. 165 °F /74 °C Cover Plate The operating mechanism consists of Maximum Working Pressure: a liquid - filled 3mm or 5mm frangible 250 psi (17.3 bar) - U.L. & cUL only capsule that is only 20 mm in length. Operation: The Central GB4 and 175 psi (12.1 bar) all other agencies GB4 -FR sprinklers absorb heat through Factory Hydro Test: the ceiling cover plate which is soldered to 100% at 500 psi (34.5 bar) the adjustable retainer ring with a fusible alloy. At the rated temperature, the alloy No. 1-8.0 Old Cat. No. 3.10.5 Figure 1 GB4 -FR (shown) Royal Flush Adjustable Concealed Pendent (Non - Activated) I / 1 /2- (15mm)NPT I 1 1 1 2 1 /2 ° ±1 /8°(63.Smm 1 Hole Diameter 1 / I I I 7/16' I I (11.1mm) I I I I (ref.) I I Face of Fitting j Support Cup L -__ _ -J — I' / ) \ N E S '",°:. m C tE o 0 aE L I u" m N _ O t n , � I . i - f.....41 I \ / • , I . i • I a 8 1 Ceiling Line I • 3 1/4° (82.6 mm) Diameter Cover Plate/ Retainer Assembly Figure 2 GB4 or GB4 -FR Royal Flush Adjustable Concealed Pendent (Activated) ■ , 1/2115mm) NPT 1 I 1 1 2 1/2° ±1 /8°(63.5mm ± 3.2mm) Hole Diameter • 1 1 I I 1 I 1 7/16° (11.1mm)(ref.) 1 I I I I Face of Fitting + Support Cup L -- __ -- — ) , ,, 2° ±1/4° (50.8mm ± 6.4mm) I \ r --- '‘ 1 I I J 1 _ • , I I L I j Ceiling Line Cover Retainer 2 - b, Design GB4 Wrench (Part #1075) Data Design Requirements - Standard Applications e 155 °F /68 °C and 200 °F /93 °C : Listing /Approval Sprinkler Designation Bulb Type UL, cUL, FM, MEA GB4 5mm- , UL, cUL, FM, MEA GB4 -FR 3mm. The GB4 Royal Flush Adjustable Concealed Pendent Sprinkler is UL, cUL and MEA Approved for standard area coverages and standard flow and pressure requirements as specified in current NFPA 13 Standards for light and ordinary hazard occupancies and FM Approved for light and ordinary hazard in accordance with the F.M. guidelines. The GB4 -FR is UL, cUL and MEA Approved for Quick Response Applications for standard area coverages and standard flow and pressure requirements as specified in current NFPA 13 Standards in both ordinary and light hazard. The GB4 -FR is FM Approved (but not as quick response) for light and ordinary hazard in accordance with the F.M. Guidelines. Ceiling cover plates are available in a variety of metallic or painted finishes. For custom painted finishes, the customer must furnish a quick -drying paint, preferably lacquer- based, to ensure proper color duplication. One quart of paint is required for each 200 plates. - of a thread leak, remove the unit, inside the threaded support cup. A apply new pipe joint compound or leak tight joint requires a only 7 to 14 I nstallation tape, and reinstall. ft. lbs. (9.5 - 19.0 Nm) of torque. Torque levels greater than 21 ft. lbs. (28.6 Nm) Installation Sequence may distort the orifice seal, resulting The Central GB4 and GB4 -FR must in leakage. be installed in conformance with Step 1. The unit must be installed in current NFPA 13 Standards. Devia- the pendent position. Step 5. To install the ceiling cover tions from these requirements and plate, manually thread the cover standards, or any alteration to the Step 2. The face of the sprinkler retainer into the support cup. Con - sprinkler assembly itself will void any fitting should be installed a nominal 2" tinue threading until the cover warranty made by Central Sprinkler ±'/4" (5o.8 mm ±6.4mm) behind the retainer's flange rests against the Company. In addition, installation finished ceiling line. Adjustments, to surface of the ceiling. must also meet local government compensate for variations in fitting provisions, codes and standards, as face to ceiling height, may be made Caution: Special care must be taken applicable. by threading the cover plate retainer when installing with a CPVC system. in or out of the support cup. Sprinklers must be installed after the The system piping must be properly manufacturer's recommended setting sized to ensure the minimum re- Step 3. Use only a non - hardening time for the solvent cement system to quired flow rate at the sprinkler. pipe joint compound, or Teflon* tape. ensure that neither accumulate within Check for the proper model, style, Apply only to the male threads. the sprinkler. orifice size and temperature rating 'Teflon is a trademark of the DuPont Corp. Special care must be taken when prior to installation. Install sprinklers installing with a copper system. after the piping is in place to avoid Step 4. Hand tighten the sprinkler Sprinklers must be installed only after mechanical damage; replace any into the fitting. Avoid making contact the inside of the sprinkler drop and damaged units. Wet pipe systems with the deflector when using the associated fittings have been wire must be protected from freezing. Central Sprinkler GB4 Wrench to brushed to remove any flux. Re- tighten the unit into the fitting. The sidual flux can cause corrosion and in Upon completion of the installation, GB4 wrench is designed to mate extreme cases can impair proper the system must be tested per with the frame's wrench bosses, sprinkler operation. recognized standards. In the event 3 CENTRAL , ' = ' • • - • • Riser Manifold ._ ..... ,, -, .,, ,_ • Commercial. - NFPA 13 Systems - I .. • Floor Control - High Rises • Residential - NFPA 13D/13R Systems c, - s Ma by: Central Sprinkler Company ��� "'' G —d�� // : I �- 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 �' Pr oduc t Description The Riser Manifold is approved for -__ _ - J installation in either the horizontal or L— the vertical p osition. s. The optional relief valve assembly is 4 _ � z it The Central Riser Manifold provides available for the required locations :.si - l all of the accessory equipment for a such as NFPA 13 Section 3 -1.2 which -- �u1 ^"� 'Eh riser in a single assembly. The requires relief valves on gridded , — o; „ availability of the Riser Manifold in systems." different configurations allows cost- - �' effective riser installation in commer- Riser Manifolds for use in Canada only % . - i cial (NFPA 13) systems, high rises are provided with a Waterflow Switch requiring floor control assemblies, and that has a Tamper Switch mounted 4 F L. OW ,, �Ir I residential systems (NFPA 13R/13D). inside for cover removal detection. The threaded ends of the 1" and 1'/2" bodies and the grooved ends of the 2" Technical through 6" bodies allow for an easy transition to either check or control Data valves. 1 11 1 1 / 2 11 � Models: 13 (commercial) ' ' ' The exclusive and dedicated flow 13D (residential) or switch designed for the manifolds has 13D/13R (residential) 2 02" 4" been tested and Listed for use in this specific configuration by Underwriters Styles: Threaded or Grooved ' ' Laboratories. Sizes: 1 ", 1' 4', 2 ", 21/2", 3 ", 4" & 6" Approvals: U.L., U.L.C., FM. & 6" Riser Manifold bodies are painted fire protection red. Lettering clearly M.E.A. (142 -94 E) identifies flow direction as well as the • 1" Version is Not MEA Approved. Manifold test and drain outlet, thus providing Maximum Working Pressure: 175 psi the required sign. Pressure tested at: 200 psi The Model F202 inspectors' test valve Standard Finish: Fire Protection Red and the Model F101 trim valve are with White Lettering both U.L. Listed and make the best I.P.S. Cut Groove Specs.: AWWA C -606 use of special thread combinations, eliminating the use of pipe nipples and Take -out Dimensions: See Figures the resulting potential for leakage. Shipping Weight: See Figures Installation is simplified with one Mfgr. Source: Domestic -- convenient take -out for the threaded Optional Accessories: Pressure versions as well as one take -out for all Relief Valve Kit, see page 5 grooved sizes, 2" through 6 ". No. 28 -1.0 Figure 1 I • 1" Threaded Residential Trim — Model 13D 518' Both Ends • 0 i AND i ail o o =M Si. Figure 1 - Bill of Material � 1" Threaded Residential Trim .■, US O Detail No. Eril=in No. Description Req'd Part # ■ � NU 1 Manifold Body F x F 1 971 - 064 -00 ® 2 Potter Waterflow Switch #VSR -SF 1 2448 3 ' e " 3 1/4" Gauge, Water 1 2343 FM p0 4 • 3 /4' 90° Street Elbow 1 611 - 800 -24 4' 0 4 5 3 /4" x Close Nipple 1 131 -50 -000 FLOW 6 3 /4' Ball Valve 1 41303 INN 7 Tamper Switch (U.L.C. Only) 1 2649 518' A ILA 0 8 Label (U.L.C. Only) 1 971 - 111 -00 _ Approximate Trimmed Weight - 7.5 lbs. 31/8' 4 Note: Items 7 & 8 used on Manifolds for use in 3 3/4' 103/4" Canada Only. Figure 2 1'h" Threaded Residential Trim — Model 13D/13R • Referance Fig. 2 & 3 Billl of Materials (Pg.3) • 11" ■ . 4" • • 6 "-I" '5/8" ® Male x Male Body Option ill ` 8 MM. • 15 ,..0 V 1 II H a nd / "11 1/4" Dra L 16 ® 0 0 �r, 2 ' 9 3/8" 1 *End o f pipe to end of pipe. 11 /� 0 O I• "5/8 BA FLt VIII'• 2 ' ' • ■ I ♦ Approximate Trimmed Weight - 9.0 lbs. 'Approximate thread engagement. The width of the Riser Manifold is approximately 3'/2 ". Note: Items 16 & 17 used on Manifolds for use in Canada Only 2 Figure 3 ' 1'/2' Threaded Commercial Trim — Model 13 • (For optional pressure relief valve, see Figure 6) '-- • -61/4" •� -6 "+ 4 7A • -5 1/4 Male x Male Body Option '5/8' 15 —t r : 1 u i 1z t = ® '11 1/4' O III I1 — e ' m 0 'End of pipe to end of pipe. 14 3/8" }ant 10" I I. OO '9 3/8" o ® ® . Q O Q _ m Ft - !11111! —f i 6 + Approximate Trimmed Weight - 11.5 lbs. , 1 /e Hill' '5/8" 's8' ; ' Note: Items 16 & 17 used on Manifolds for 'Approximate thread engagement. use in Canada Only. Figure 2 & 3 - Bill of Material 1 Residential and Commercial Riser Manifolds (for replacement parts) Detail No. Req'd Part Detail No. Req'd Part No. Description Comm. Res. Number No. Description Comm. Res. Number 1 Manifold Body M x F 1 1 971 - 075 -00 10 /4" x 2W Nipple 1 0 131 -20 -000 2 Potter Waterflow Switch #VSR -SF 1 1 971- 096 -00 11 1" x 1/2" x 1" California Tee 0 1 42000 c-- 3 1" Ball Valve F101 0 1 41304 12 1/2" Pipe Plug 1 1 8010 -12 -00 4 1" x'' /z" x 1" Reducing Tee 1 0 611 - 822 -12 13 1" x Close Nipple 0 1 131-65-000 5 1" Insp. Test & Drain Valve F202 1 0 971 - 079 -00 6 Sight Glass M x F 1 0 2567 14 1" Ball Valve F101 1 0 971 - 082 -00 7 1/2" Water Pressure Guage 0 1 2343 15 1'W Close Nipple MxM 1 1 131 -65 -003 7a '/" Water Pressure Guage 1 0 2585 16 Tamper Switch (U.L.C. Only) 1 1 2649 8 ' /:" Plug 1 0 816 -12 -000 17 Label (U.L.C. Only) 1 1 971 - 111 -00 9 '/+" 3 -Way Valve 1 0 41320 Figure 4 2" Grooved Residential Trim — Model 13D/13R (For optional pressure relief valve, see Figure 6) • 11 3/4" • a 4 1/2 " —> .4— 6 1/4" • . 2" Male x Groove Body Option ® 't 1 2 i 1111 D « Ill \ F LOW '13" a, CI — ©O 0 ;-; 13" O ll IIhI ' 'End of pipe to end of pipe. 0 m ® t =111111! - N> F 1 W 1 Approximate Trimmed Weight - 11.5 lbs. I Note: Items 17 & 18 used on Manifolds for use in 2 1/4" ; '2 7/8" Canada Only. • 'Approximate thread engagement. 3 I Figure 5 2 ", 2 ", 3 ", 4" & 6" Grooved Commercial Trim — Model 13 (For optional pressure relief valve, see Figure 6) • C • 0 0 11 0 ® : II II i = - 111 o �� ��:- © 'N.. 16 161/4" ..13., ©O� 0 A tio ©m lon1111 O it 0 U FLW IIIIII! um ..• 0 O 0 B I Approximate Weights & Dimensions of Trimmed • $ ■$ 2 ", 2'/2 ", 3 ", 4" & 6" Grooved Commercial Riser Manifold MINH Size A B• C D (lbs.) X 5/8" I �— D • 2" 14" 3 /8 " 13h /2 51/2" 14.0 Approximate thread engagement. 21/2" 14'/2" ' /s 14 6' /a" 20.0 • • 13" is the take -out for all sizes 2" through 6 ". 3" 141/2" ' /8" 151/2" 6W 23.0 4" 18'/2" 4' 44" 181/2" 8 39.0 Note: Items 17 & 18 used on Manifolds for use in 3 „ , „ , ,• 3 „ Canada Only. 6" 18/4 5/e 20/2 9/4 55.0 Figure 4 & 5 - Bill of Material Residential and Commercial Riser Manifold (for replacement parts) Detail No. Part Detail No. Part No. Description Req'd Number No. Description Req'd Number 1 2" Manifold Body Groove x Groove 1 971 - 077 -01 6 '/4" Water Gauge 1 2585 1 21/2' Manifold Body Groove x Groove 1 971 - 077 -02 7 V." Plug 1 816 -12 -000 1 3" Manifold Body Groove x Groove 1 971- 077 -03 8 '/." 3 -Way Globe Valve 1 41320 1 4" Manifold Body Groove x Groove 1 971 - 077 -04 9 '/" x 2" Nipple 1 131 -19 -000 1 6" Manifold Body Groove x Groove 1 971 - 077 -05 10 1" Plug 1 611- 800 -60 la 2" Manifold Body Male x Groove 1 971 - 077 -06 11 1" x 'A" x 1" Tee 1 611 - 822 -12 2 Potter Waterflow Switch #VSC 1 971 - 097 -00 11/4" x' /2" x 1 /." Tee 1 611 - 822 -13 3 1" Ball Valve (2" body) F101 1 971 - 082 -00 2" x' 'A" x 2" Tee 1 611 - 822 -14 3 11/4" Ball Valve (2'/2" & 3" body) F101 1 971- 083 -00 12 1/2" Pipe Plug . 1 8010 -12 -00 3 2" Ball Valve (4" & 6" body) F101 1 971- 084 -00 13 1" x '/2" x 1" California Tee 1 42000 4 1" Inspectors Test & Drain (2" body) F202 1 971 - 079 -00 14 1" x Close Nipple 1 131 -65 -000 4 11/4" Inspectors Test & Drain 1 971 - 080 -00 15 1" Ball Valve F101 1 41304 (2'/2" & 3" body) F202 16 2" Paddle 1 971 - 099 -00 4 2" Inspectors Test & Drain 1 971 - 081 -00 16 21/2" Paddle 1 971 - 086 -00 (4" & 6" body) F202 16 3" Paddle 1 971 - 100 -00 5 1" Sight Glass (2" body) 1 2567 16 4" Paddle 1 971- 107 -00 5 11/4' Sight Glass (2W & 3" body) 1 2568 16 6" Paddle 1 971 - 106 -00 5 2" Sight Glass (4" & 6" body) 1 2569 17 Tamper Switch (U.L.C. Only) 1 2649 18 Label (U.L.C. Only) 1 971 - 111 -00 4 Figure 6 , - Optional Pressure Relief Valve Grooved Commercial Trim — Model 13 • r:Sti Optional Pressure Relief Valve Accessory Kit P rY � 4 (Order Part #4063) y � ,,.. ,,, ��•E Ily 1 ) Detai No. Part s — 2 I No. Description Req'd Number 1 II* Dl • O r i 1:= 1 90° Compression Fitting 2 198 - 068 -02 1 r 2 Yz" Watts Pressure Relief Valve 1 198 - 066 -00 O I ' Q 8 Model FP53L (U.L., F.M.) t 3 11 " Reinforced '' /z ' /2' Tubing 1 198-143-00 II <.� 4 1 x° Reducing Bushing 1 611 - 800 -49 Normally ■ ■ 0 Above kit can be installed on all sizes of grooved bodies. in Drain ; V alve is factory set at 175 psi (non-adjustable). Position ® /� = rY P ( 1 ) '^ FLbw — Note: If optional pressure relief is desired for Figures 2 and t I i 3, outlet on riser must be provided. l Normally Closed Figure 7 Potter Waterflow Switch Terminal Connections SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL Caution: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serves as two separate connections. The wire • N''.1"."■,,,,,k,". must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. Figure 8 Potter Waterflow Switch Typical Electrical Connections LOCAL BELL STYLE B / CLASS B TRANSFORMER OR (END OF LINE RESISTOR) BATTERY POWERED CKT. (SEE NOTE) END OF OPEN ON ALARM ! CLOSE ON OPEN ON CLOSE ON LINE //! 1 ALARM ALARM ALARM RESISTOR SIGNALING DEVICE SUPERVISED LOOP (SEE NOTE) TYPICAL SWITCH ACTION TO ADD'L A. FROM OPEN ON CLOSE ON DEVICES OPEN ON \l : CLOSE ON CONTROL 'ALARM ALARM OR RETURN do ' ALARM PANEL _A.__,.. TO CONTROL Note: For supervised circuits, see "Switch Terminal Connections" and caution note (above). The Model VSR -SF has two switches, one can be used to operate a central station, proprietary or remove signalling unit, while the other contact is used to operate a local audible or visual annunciator. Testing: The frequency of testing for the Model VSR -SF and its associated protective monitoring system should be in accordance with applicable NFPA Standards and/or the Authority Having Jurisdiction, but under no circumstances less than bimonthly. Figure 9 Potter Tamper Switch Typical Electrical Connection CONTACTS: S.P.D.T. (Form C) N.C. If O COM. CONTACTS SHOWN WITH CONTACT RATING: 5A @125V AC COVER IN PLACE. 2.5A @ 30V DC N.C. INSTALLATION FOR MODELS VSR -F, VSR -CF, AND VSF -SF Remove the one retard assembly mounting screw. Place the switch assembly over the retard assembly mounting tab. Replace the screw. 5 ;, Central Grooved Piping Products al • Butterfly Valve • — _- .- Figure BFV 0 Fire Protection Butterfly Valve Manufactured by: Central Grooved Piping, Products a Subsidiary of Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Phone (215) 362 -0700 Fax (215) 362 -5385 la Product Technical 0 Installation Description Ull Data Central Butterfly Valves provide for Figure No.: BFV In piping systems, butterfly valves efficient control of fluid flow in piping Size: should be located where they will be systems. Flow may be from either 2 ", 3 ", 4 ", 5 ", 6 ", 8 ", 10 ", & 12" readily accessible for operation, direction, and the valves may be Approvals: inspection, and maintenance. positioned in any orientation. The UL, FM, and ULC (indoor and When a valve "closes hard ", it may be valves are furnished with grooved outdoor use) (See Central Fire due to debris lodged in the sealing ends and can be easily adapted to Protection Submittal Sheet for area. This may be corrected by flanged components utilizing our exact Listing/Approval backing -off the handwheel and Figure 71 Class 150 flange adapters. information.) closing it again, several times if The body and disc construction Manufacture Source: necessary. The valve should never provides for increased strength and Domestic be forced to seat by applying a durability. The Figure. BFV Butterfly Materials of Construction: wrench to the handwheel as it may Valve is provided with 2 sets of SPDT Body: distort the valve components or score Supervisory Switches for use in Ductile Iron in accordance with the sealing surfaces. outdoor and indoor applications. A ASTM A -536, Grade 65 -45 -12 high strength conventional stainless Body Coating: Before installing conduit at the steel upper stem is provided for Black PPS (Polyphenylene Sulfide) actuator, remove the rubber grommet dependability as compared to iron Disc: at the connection. upper stems provided by others. The Ductile Iron in accordance with Important: All replacement parts surfaces at the upper stem and lower ASTM A -536, Grade 65 -45 -12 must be obtained from the trunnion areas incorporate a reduced Disc Seal: manufacturer to assure proper dynamic torque and anti - compression Grade "E" EPDM encapsulated operation of the valve. set design to ensure low operating rubber in accordance with torque and seal longevity. ASTM D -2000 To prevent rotation of the valve, it is Upper Stem: recommended that the BFV Butterfly This innovative feature prevents Type 440 Stainless Steel Valve be installed with rigid type elastomeric failure of the disc Lower Plug: couplings, such as the Central Fig. encapsulation that is commonly C360 Brass 772 Coupling. If flexible couplings are used, additional support may be experienced with other manufacturers. Operator: needed to prevent rotation. This is accomplished by providing Gear operator with Iron Housing — uniform compression throughout the Coated with Black Epoxy Note: Never disassemble or opening and closing operation of the Bracket: remove any valve component disc. Other manufacturers have non- Steel — Black Zinc Plated without verifying that the system uniform compression, which results in Factory Hydro Test: is depressurized and drained. permanent compression set and 100% @ 350 psig (2413 kPa) in subsequent splitting of the material accordance with MSS- SP -67, UL, and undermining of the seal. ULC and FM requirements Maximum working pressure: 175 psig (1207 kPa) Central No. 15 -3.0 BUTTERFLY VALVE - BFV WIRING DIAGRAM (4" Configuration shown) Switch Rating: 15A 125, 250 VAC SUPERVISORY TAMPER � 0.25A 250 VDC SWITCH CIRCUITS m"'r °`""` 0.50A 125 VDC (VALVE FULLY OPEN) " BUTTERFLY VALVE - BFV SIDE VIEW W/ VALVE OPEN FRONT VIEW W/ VALVE OPEN MP uoa Lt. PMTror+noiuroa F °1D w CHASSIS wn �� 1 FE lNE 1 T FOB � F NC atom \��� \n�lllC� !WORN !WORN 1 VOLTAGE ■ YI►aY ■_-II S2 - Y . r.'"----t II II a I U MO CCM E LOCAL WAl1NY SMFCM TO BE 001*E0 M000M BE LOCAL aw wnomilnvra .aar.c 1 iii I • G E G 0 A Ordering �rl Information A B C D E F G Weight Ordering Information: When Size Inches Inches Inches Inches Inches Inches Inches lbs. placing an order, indicate the full Inches product name. Please specify the mm mm mm mm mm mm mm Kg quantity, figure number, type of disc 21/2 5.34 10.41 7.22 2.88 3.81 5.72 N/A* 12 seal, EPDM "E" and size. 135.6 264.4 183.4 73.0 96.8 145.3 5.4 3 5.67 11.38 8.75 3.50 3.81 5.72 N/A* 14 Availability & Service: Central 144.0 289.1 222.3 88.9 96.8 145.3 6.3 Grooved Piping Products, valves, 4 6.76 12.70 9.65 4.75 4.56 5.72 N/A* 22 accessories, and other products are 171.7 322.6 245.1 120.7 115.8 145.3 10.0 available throughout the U.S., 5 7.15 14.56 10.23 6.25 5.81 6.18 N/A* 31 Canada, and internationally, through 181.6 369.8 259.8 158.8 147.6 157.0 14.1 a network of Central distribution 6 7.88 15.23 10.96 6.75 5.81 6.18 N/A* 36 centers. You may write directly to 200.2 386.8 278.4 171.5 147.6 157.0 16.3 Central or call 215 - 362 - 0700 for the 9.24 17.50 13.37 10.00 5.25 6.43 1.22 52 distributor nearest you. 8 234.7 444.5 339.6 254.0 133.4 163.3 31.0 23.6 11.56 21.00 15.68 12.00 6.25 6.43 1.75 81 Warranty: Central will repair and /or 10 replace any products found to be 293.6 533.4 398.3 304.8 158.8 163.3 44.5 36.7 12.70 23.25 16.83 14.25 6.50 6.43 2.62 97 defective in material or workmanship 12 within a period of one year from the 322.6 590.6 427.5 362.0 165.1 163.3 66.5 44.0 date of shipment. Please refer to the * END OF DISC DOES NOT EXTEND BEYOND VALVE BODY. current price list for further details of the warranty. CENTRAL GROOVED PIPING PRODUCTS ©1998 Central Grooved Piping Products BFV.09.98 Printed in U.S.A. +g-usoazro -dam° y SPECIFICATIONS AND INSTALLATION INSTRUCTIONS BB-SC SERIES 1 � butterbal® SLOW CLOSE INDICATING BUTTERFLY VALVES FOR OPMIHMIL, 1 ,(A BYO" iFfel Factory V M tem C � US S LISTED acrox EVERY VALVE MILWAUKEE VALVE SCiD - 12/97 SPECIFICATIONS FOR SLOW CLOSE II SLOW CLOSE BUTTERBALL VALVE INSTALLATION ASSEMBLIES A. The BBSC can be installed in any orientation in PATENTED a piping system using standard National Pipe Threads. Wrench should be used to hex on the 1. Provides slow opening and closing properties end of valve being threaded to pipe. Pipe in a quarter -turn valve. The purpose is to elimi- sealants should be used sparingly. nate hydraulic shock and water hammer in fire protection and other liquid systems. B. The valves with internal switches can be easily wired in the field. They will have two switches, 2. Available with or without an internal, pre -wired switch -1 will have dual leads on the terminals. supervisory tamper switch assembly. When This switch is to be connected to the supervisory mounted on any slow -close valve and wired, the circuit of a Listed alarm control panel. Switch -2 switches signal movement of the valve disc from will have single leads and may be connected to the full open position. auxiliary equipment per direction of the local a. Available factory mounted to a valve or as a authority having jurisdiction. Cap any unused kit for field installation on previously installed wire leads with wire nuts and tuck into junction valves. box. All connections shall be reviewed and approved by the local authority having jurisdiction. b. Switch Rating: 10 Amps /115 VAC -60 Hz C. A 14 gage green wire has been fastened to the 0.5 Amps /28 VDC interior of the housing and is to be used as a c. Valves equipped with tamper switch assem- housing ground. blies are FOR INDOOR USE ONLY. D. Recommended type of wire to be used is No. 16 Dual Rated UL 300V 80 C and 300V 105 C. 3. UL /FM rated at 175 psi. Also available at 350 psi and 500 psi with N.Y.C. B.S.A. approval. E. Installation must be in compliance with NFPA 72 and 13, or bonded and grounded per Canadian Electrical Code Part 1. Factory F. The BB -SC, BBHSC (threaded -end) and BBVSC, Mutual ual C ® k Us BBHSC (grooved -end) valves are intended for use with schedule 40 and /or 80 pipe, sizes LISTED 1", 11/4 ", 1'/z ", 2" and 2'/2" per ANSI B36.10. For use with fire protection sprinkler systems 175 psi. Approved by the New York City Board of Stds. & INSTALLATION FOR NEW YORK CITY VALVES Appeals under Calendar No. 996- 81 -SM, for N.Y.C. special valves have a large flow indicator 175 psi and Calendar No. 720 -83 -SA for 350 psi which points in the direction of the valve disc, indi- and 500 psi. cating open or closed. The valve should be installed (500 psi rated valves not shown.) in a position where the indicator is readily visible. MODEL DESCRIPTION SIZES BB-SC100 Valve Less Switch UL/FM 1", 1'/: 1 /z BB -SCS02 Valve With Switch 175 psi - Threaded Ends NYC BSA 2' 21/2' Approved BBVSC100 Valve Less Switch UUFM BBVSCS02 Valve With Switch 175 psi - Grooved Ends NYC BSA 21/2' Approved BBHSC100 Valve Less Switch 350 psi - Threaded Ends NYC BSA 1', 1 1' /s BBHSCS02 Valve With Switch Approved 2', 21/2' BVHSC100 Valve Less Switch NYC BSA BVHSCS02 Valve With Switch 350 psi - Grooved Ends Approved 2' 2Y: 2. utterb�l BUTTERFLY VALVES - VALVES LESS SUPERVISORY TAMPER SWITCH ASSEMBLY 42 I . -AID OIN GRID GRI GRID illirrillin 11 1 1 7 4 kt e # MA r I ,l i ` , ,l J y / `.. L, -C1 �I 14 I �y'� I pyA�N/ I !YNA�/� �� L__.. I .. .. .. A .. BB -SC100 (Threaded Ends) BBVSC100 (Grooved Ends) Sizes 1", 1'/4 ", 1'/2", 2 ", 2' /2" Size 2'/2" VALVES WITH SUPERVISORY TAMPER SWITCH ASSEMBLY • 4i 0 email u la I � � FLOW 0!I 111701.j .._ti ima O ��� 7 rick; I MO O imi., •� li b .. — O �; "Iry 1 CZ% Is GRID ;,` i 4 i� /� y •J' plus 1 Inches ® 7 � II 0 � I i l I .I I I I II II l MI L..„. _J !LIMN _i -E- ..p.. ..A" .. G.. NYC INDICATOR THREADED ENDS t end non -swnced switched and ENDS BB -SCS02 BBVSCS02 DIMENSIONS - INCHES SIZE 1' 1 1/4- 1 1/2' 2 2 1/2 MATERIAL LIST A 2 1/8 25/8 2 7/8 3 1/4 4 1/8 NO. PART MATERIAL SPECIFICATION B 3 15/16 4 9/32 4 1/2 5 5 13/32 C 1 9/16 1 15/16 2 3/16 2 3/4 3 5/16 1 Indicator Sintered Iron F0008P D 1 23/32 2 7/64 2 3/8 3 1/16 3 1/2 E - - - - 15/16 2 Housing Bronze ASTM 584 F - - - 5/8 G - - - - 41/2 3 Body Bronze ASTM 584 H - - - - 2 7/8 J 415/16 51/8 519/32 61/8 61/4 4 Handle Brass K .66 .73 .73 .79 1.18 5 Disc Stain. Stl. Type 304 L .83 .90 .99 1.41 1.29 yP M-40 1.05 1.38 1.61 2.07 2.47 6 Disc Seal EPDM Elastomer M -80 .96 1.28 1.50 1.94 2.32 _ N-40 2.25 2 2.5 2.25 10 7 Switch Housing Die Cast Aluminum W 13/16 1 1/4 1 13/32 1 11/16 1 3/4 g _ M -40 ARE DIMENSIONS USING SCHEDULE 40 PIPE M -80 ARE DIMENSIONS USING SCHEDULE 80 PIPE N -40 IS FLOW RESISTANCE EXPRESSED IN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE W IS THE WRENCH MAKE -UP LENGTH :3. P P TT BELLS ® P BA -AC & PBD - DC Potter Electric Signal Company Potter Electric Signal & Mfg., LTD. 2081 Craig Road • P.O. Box 28480 55 Glen Cameron Road St. Louis, MO 63146 -4161 Thornhill, Ontario, Canada L3T 1P2 (314) 878 -4321 • (800) 325 -3936 (905) 882 -1833 UL LISTED, FM APPROVED Sizes Available: 6° (150mm), 8" (200mm) and 10" (250mm) N- Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized ® POTTER .�. 24VDC (20.4 to 31.2) Polarized Cti°vao•04 .1.77.410;211.4 Service Use: Fire Alarm General Signaling <5> a Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150 °F ( -40° to 66 °C) (outdoor use requires weatherproof backbox) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating 6" BELL SHOWN Optional: Model BBK -1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK -1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK -1, Stock No.1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT -IN TRANSIENT PROTECTION: SIZE CURRENT TYPICAL dB MINIMUM dB INCHES (mm) VOLTAGE MODEL NO. STOCK NO. (MAX) AT 10 FT. (3m) AT 10 FT. (3m) ( ( 6 (150) 12VDC PB0126 1706012 .12A 85 76 8 (200) 12VDC PBD128 1708012 .12A 90 76 10 (250) 12VDC PBD1210 1710012 .12A 92 76 6 (150) 24VDC PB0246 1706024 .064 87 76 8 (200) 24VDC PBD248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 6 (150) 24VAC PBA246 1806024 .17A 91 76 8 (200) 24VAC PBA248 1808024 .17A 94 76 10 (250) 24VAC PBA2410 1810024 .17A 94 76 6 (150) 120VAC PBAl206 1806120 .05A 92 82 8 (200) 120VAC PBAl208 1808120 .05A 99 82 10 (250) 120VAC PBAl2010 1810120 .05A 99 85 Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laborato- ries as specified in UL Standard 464. UL temperature range is -30° to 150 °F ( -34° to 66 °C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indica- tive of output levels in an actual installation. PRINTED IN USA MKT. #8850001 - REV N PAGE 1 OF 2 MFG. #5400776 - 11/95 .. P POTT BELLS ® P BA -AC & PBD -DC DIMENSIONS INCHES (mm) . FIG. 1 BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE 1 0 10" . ( 2so) _ 8" I 1 5 3/4" O 3 3/8" 5 ( 200) 6" (146) (B (1z7) I (150) � z ::i ' J —1 " -- 11 5 /6 3 66 ) I (B6) (41) 4 ,/4" 2 11/16" (108) (68) DWG. #776 -1 DWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) A gglim bh. RED (OUT) WHITE (IN) Ai iiih i,. WHITE (OUT) FROM CONTROL PANEL 101311 TO NEKT BELL FROM CONTROL PANEL OR OR ENS- OORUNE DR • '�' PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) - U ' BLACK (OUT) BLACK (IN)�' BLACK (OUT) CAUTION; CAUTION. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY 2. RED WIRES POSITIVE (+) AFTER LAST BELL. 3. BLACK WIRES NEGATIVE ( -) 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776 -3 INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2.4m) from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV N PAGE 2 OF 2 MFG. #5400776 -11/95