Loading...
Plans 141` . REPLACE EXISTNG CARRIER UNIT (48D0006 5 TON) ® S-/�gM.'Z'1c>-I� e,r urT` sti��.iifi WITH NEW LENNOX UNIT (GCS16 -060 5 TON) ' ' ( 1 REVISIONS , z au li NEW RTU -1 RTU -1 CLEAR FROM ANY EXHAUST VENTS i- 1/2'x21 "BEAM 01111 (MINIMUM 10' CLEARANCE) NEW RTU -1 PAM l 2x6 TOUNGE & GROOVE DECK i_ 3/4" GAS = x Ill 1; RECONNECT EXISTING DUCT 5 1/2 "x21 " BEAM xs AND GAS LINE AT UNIT • 9 J a, 77 a _ .4_. I. . cid ;-I N cd N C/1 It HVAC ROOF LAYOUT ROOF FRAMING LAYOUT 0 P4 4 ' 1 SCALE: t/8' =10' SCALE: 1/4% t'0' • � tj (In „ N • = 0 a1 o �tn L� H MECHANICAL EQUIPMENT SCHEDULE ^ HVAC LAYOUT CAD PV( EQUIPMENT L C. DESCRIPTION BASIS OF DESIGN TAG CITY OF TIGARD RTU -1 ROOFTOP UNIT LENNOX Approved Conditionally Approved A 1 ] DATE 02/04/03 1990 CFM © .8" ESP, 3/4 HP MOTOR, BELT DRIVE GCS16 -060 1 For only the work. described in: 58.5 MBH TOTAL COOLING © 80 67'F (db/wb) RET. & 95 10.0 SEER PERMIT NO. _______________ DRAWN BY sRm 75.0 MBH HEATING INPUT, 80.0% A.F.U.E. / 208 230 3PH See Letter to: Follow � � SCALE � /s- =�• -o- 29.0 MCA - _ I ? a , ja PROV WITH ECONOMIZER AND PROGRAMMABLE THERMOSTAT (HONEYWELL T7300) bAddr t o "1 526 lbs. y Date: -/�-- _L M PROJECT ® 80236 • PACKAGED GAS / ELECTRIC LENNOX GCS16 - 024 - 030 - 036 - 048 -060 •?� , ENGINEERING DATA 2 to 5 Ton (7.0 to 17.6 kW) ti ' AFUE -80% i` , �..� SEER - up to 10.35 \ . Net Cooling Capacity 23,200 to 58,500 Btuh (6.8 to 17.1 kW N. I r .. . g g p Y ( kW) SP m • a Input Heating Capacity - 50,000 to 120,000 Btuh (14.7 to 35.2 kW) ��,ncv an Bulletin No. 210169 September 2001 Supersedes December 2000 [ c, i' "', ___ _. Iambi � . . .._.. _ '_, .. , w\ 1 r 2.- 'I- -'-' ' ' ',) 2 !/ ' / , ,1 ir OD ‘ r 1 . t �� { N „ � Rooftop Installation With Combination t . " - A11111■. ' . ' . - - f :.. - . 1:1 .,- ., . ' oll e,..46,_1 /1 °.. t f '-� . �i. Supply and Return Air System �. r . ,:. \ ,, 4 t I v , i I 0,-,,,,,, ?• Y I �� tti Basic U lira .► ' , � � Basic Unit � / / Rooftop Installation With Horizontal Economizer MODEL NUMBER IDENTIFICATION GCS 16 X - 036 - 120 - 1 Y Unit Type I Voltage GCS = Packaged Gas Heat/Cooling Unit Series P = 60 V = 2081230v -3 208/230v -1 phase phase -60hz hz G = 460v -3 phase -60hz Low NO Models J = 575v -3 phase -60hz Cooling Capacity Tons (kW) - Minor Revision Number 024 = 2 (8) • 030 = 2.5 5 (8.8) _ Heating Capacity Btuh (kW) 036 = 3 (10.6) 50 = 50,000 (14.6) 048 = 4(14.1) 75= 75,000(22.0) 060 = 5 (17.6) 90 = 90,000 (26.4) 120 = 120,000 (35.1) FEATURES Application - AFUE of 80 %. - SEER up to 10.35. - 2 through 5 ton (7.0 through 17.6 kW). - Single and three phase power supply. - Bottom (down -flow) or horizontal supply and return air. - Designed for outdoor rooftop or ground level installations in light commercial applications. Approvals - Certified in accordance with the USE certification program, which is based on ARI Standard 210/240 -94. - Sound rated in the Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270 -95. - Tested in the Lennox Research Laboratory environmental test room. - Rated according to U.S. Department of Energy (DOE) test procedures. - Blower data is from unit tests conducted in the Lennox Laboratory air test chamber. �� - Units certified by CSA International (formerly AGA/CGA) and ratings are certified by GAMA. - Gas heat is tested according to DOE test procedures and FTC labeling regulations. - All "X” models meet California Nitrogen Oxides (NO,) standards and California Seasonal Efficiency Requirements. - Developed in accordance with ISO 9002 quality standards. - Each unit test operated at the factory before shipment ensuring dependable operation at start-up. NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2001 Lennox Industries Inc. SPECIFICATIONS 4 Heating Model No. GCS16 -048 -75 GCS16 -048 -120 GCS16 -060 -75 F GCS16 -060 -120 Performance Low NO Models GCS16X -048 -75 GCS16X -048 -120 GCS16X -060 -75 GCS16X -060 -120 Input - Btuh (kW) 75,000 (22.0) 120,000 (35.2) 75,000 (22.0) 120,000 (35.2) Output - Btuh (kW) 60,000 (17.0) 96,000 (28.1) 60,000 (17.0) 96,000 (28.1) *A.F.U.E 80.0% 80.0% 80.0% 80.0% Gas Supply Connections npt - in. 1/2 1/2 1/2 1/2 Rec. Gas Supply Pressure in. w.c. (kPa) Natural Gas 7 (1.7) 7 (1.7) 7 (1.7) 7 (1.7) LPG /Propane 11 (2.7) 11 (2.7) 11 (2.7) 11 (2.7) Cooling Nominal Tonnage (kW) 4 (14.1) 4 (14.1) 5 (17.6) 5 (17.6) Performance *Cooling capacity - Btuh (kW) 46,500 (13.6) 46,500 (13.6) 58,500 (17.1) 58,500 (17.1) Total unit watts 4890 4890 6570 6570 *SEER (Btuh/Watts) 10.35 10.35 10.00 10.00 EER (Btuh/Watts) 9.5 9.5 8.90 8.90 'Sound Rating Number (db) 82 82 82 82 Refrigerant Charge (HCFC -22) 5 lbs. 11 oz. 5 lbs. 11 oz. 7 lbs. 0 oz. 7 lbs. 0 oz. (2.58 kg) (2.58 kg) (3.18 kg) (3.18 kg) Condenser Net face area - sq. ft. (m Outer coil 14.3 (1.33) 14.3 (1.33) 14.3 (1.33) 14.3 (1.33) Coll Inner coil 5.9 (0.55) 5.9 (0.55) 13.7 (1.27) 13.7 (1.27) Tube diameter - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) \No. of rows 1.4 1.4 2 2 Fins per inch (m) 20 (787) 20 (787) 20 (787) 20 (787) Condenser Diameter - in. (mm) & No. of blades 24 (610) - 4 24 (610) - 4 24 (610) - 4 24 (610) - 4 an Air volume - cfm (Us) 3880 (1830) 3880 (1830) 3770 (1780) 3770 (1780) Motor horsepower (W) 1/4 (187) 1/4 (187) 1/4 (187) 1/4 (187) Motor watts 340 340 360 360 Evaporator Blower wheel nominal diameter x width - in. (mm) 11 -1/2 x 9 11 -1/2 x 9 11 -1/2 x 9 11 -1/2 x 9 Blower (292 x 229) (292 x 229) (292 x 229) (292 x 229) Motor horsepower (W) 3/4 (560) 3/4 (560) 3/4 (560) 3/4 (560) Evaporator Net face area - sq. ft. (m 5.3 (0.49) 5.3 (0.49) 6.2 (0.58) 6.2 (0.58) Coil Tube diameter - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) . No. of rows 2 2 2 2 Fins per inch (m) 15 (591) 15 (591) 15 (591) 15 (591) Condensate drain coupling size npt - in. 3/4 3/4 3/4 3/4 No. & size of cleanable polyurethane filters - in. (mm) (1) 20 x 25 x 1 (508 x 635 x 25) Shipping Net weight of basic unit - lbs. (kg) 496 (225) 496 (225) 526 (239) 526 (239) Data Shipping weight of basic unit - lbs. (kg) 1 pkg. 605 (274) 605 (274) 635 (288) 635 (288) Electrical characteristics (60hz) 208/230v - 1 ph, 208/230v - 1 ph, 208/230v - 1 ph, 208/230v - 1 ph, 208/230v or 208/230v, 460v or 208/230v or 208/230v, 460v or 460v - 3 ph 575v - 3 ph 460v - 3 ph 575v - 3 ph 'Sound Rating Number in accordance with test conditions included in ARI Standard 270. *Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations. *Certified in accordance with the USE certification program, which is based on ARI Standard 210/240: 95 °F (35 °F) outdoor air temperature and 80 °F (27 °C) db /67 °F (19 ^C) wb entering evaporator coil air. HIGH ALTITUDE INFORMATION No gas pressure adjustment is needed when operating from 0 to 7500 ft. (0 to 2285 m . See below for correct manifold pressures for natural gas and LPG /propane. FUEL Manifold Pressure (outlet) 0 to 7500 ft. (0 to 2248 m) above sea level 0 Natural Gas 3.5 in. w.g. (0.87 kPa) LPG /Propane 10.5 in. w.g. (2.61 kPa) GCS16 -2 to5 Ton / Page 6 fp. - ELECTRICAL DATA - 1 PHASE fi General Model No. GCS16 -024 GCS16 -030 GCS16 -036 GCS16 -048 GCS16 -060 Data Line voltage data - 60 hz - 1 phase 208/230v 208/230v 208/230v 208/230v 208/230v Rec. maximum fuse size (amps) 25 30 40 50 60 ( Minimum Circuit Ampacity 16 20 25 34 42 j Compressor Rated load amps 10.1 12.4 16 21.8 27.6 Locked rotor amps 60.0 69.4 100 131 135 Condenser Coil Full load amps 1.1 1.1 1.1 2 2 Fan Motor Locked rotor amps 2.3 2.3 2.3 4.2 4.2 Evaporator Motor output - hp (W) 1/3 (249) 1/3 (249) 1/2 (373) 3/4 (560) 3/4 (560) Blower Motor Full load amps 2.2 - 3.0 3.9 4.6 4.6 Locked rotor amps 4.2 6.2 8.3 10.1 10.1 Induced Draft Blower Motor (1 phase) full load amps 0.7 0.7 0.7 0.7 0.7 tRefer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 10% of line voltage. ELECTRICAL DATA - 3 PHASE General Model No. GCS16 -036 GCS16 -048 GCS16 -060 Data Line voltage data - 60 hz - 3 phase 208/230v 460v 575v 208/230v 460v 575v 208/230v 460v 575v Rec. maximum fuse size (amps) 25 15 15 35 15 15 45 20 15 tM inimum Circuit Ampacity 18 10 8 23 12 10 29 16 12 Compressor Rated load amps 10.3 5.1 4.2 12.8 6.4 5.1 17.6 9.5 6.3 Locked rotor amps 77 39 31 91 46 37 105 55 45 Condenser Coil Full load amps 1.1 .80 0.80 2 1.1 01.1 2 1.1 01.1 Fan Motor Locked rotor amps 2.3 1.9 01.9 4.2 2.2 02.2 4.2 2.2 02.2 Evaporator Motor output - hp (W) 1/2 (373) 1/2 (373) 1/2 (373) 3/4 (560 3/4 (560 3/4 (560) 3/4 (560) 3/4 (560) 3/4 (560) f ) Blower Motor Full load amps 3.9 1.9 01.9 4.6 2.4 0 2.4 4.6 2.4 02.4 Locked rotor amps 8.3 4.2 04.2 10.1 5.0 05.0 10.1 5.0 05.0 Induced Draft Blower Motor (1 phase) full load amps 0.7 I 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 tRefer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. mMotors are rated at 460 volts. Full load amps shown are for step -down transformer output. NOTE - Extremes of operating range are plus and minus 10% of line voltage. INSTALLATION CLEARANCES - INCHES (MM) GCS16 BASIC UNIT GCS16 UNIT WITH REMD16 ECONOMIZER . j� �� / / (� �� i ��j • 305) i' , i j Z R ILL1jI) ! L 1 t t A1 ```����� SINGLE /. % %�� PACKAGE �% SINGLE 36 / UNrr I PA 36 V /j /// e 914) //_ // ii Ail j V/ 36 36 914) 14) / ( _ NOTE - Top Clearance 60 in. mm) NOTE - Top Clearance 60 In. (1525 mm). ( 1524 mm NOTE - Entire perimeter of unit requires support when elevated above mounting surface. • GCS16 -2 to5 Ton / Pace 12 II. l: c • • DIMENSIONS — INCHES (MM) — BASE UNIT • /' CORNER WEIGHTS CENTER OF GRAVITY Model AA BB CC DD Model EE FF Number lbs. kg lbs. kg lbs. kg lbs. kg Number Inch mm Inch mm GCS16 -024 76 35 65 29 96 44 113 52 GCS16 -024 nj GCS16 -030 81 37 69 31 102 46 121 55 GCS16 -030 32 -1/2 826 27 -1/2 699 GCS16 -036 81 37 68 31 101 46 120 54 GCS16 -036 GCS16 -048 111 50 97 44 135 61 154 70 ' GCS16 -048 GCS16 -060 117 53 103 47 143 65 163 74 GCS16 -060 38 5/8 981 30 1/4 768 I 20-1/4 (514) OPTIONAL HF16 HORIZONTAL �/ FILTER KIT (Reid Installed, 8 I - ------7' Canada Only) 3 (76) i 3 (76) (203)$ AA I,----, I '_. BB (76) M ... —_ \ CONDENSER T \ C*ILFAN E F T I — I ( (BLOWERI I I I I I �1 FF I �i /��� t , ` I ``\ - C ONDENSER P 1 �� I O _ I I I I TARE DOWN FLOW OPTIONAL n n n n n I �- . I a RETURN AIR DOWN FLOW OAD16 OUTDOOR CE - OPENING SUPPLY AIR AIR DAMPER I I I I I }III OF GRAVITY OPENING (Field Installed) I I 'dj(C I EE FLUE OUTLET I I I I I I I I I I I I I I I C I /r \ I I \ W I11 W ^ W I COMPRESSOF1 I \I I ' i C - J J INDUCED DRAFT BLOWER D I / ( CONTROL BOX Q CC TOP VIEW BASE SECTION COMBUSTION AIR INTAKE TOP VIEW CONDENSER COIL 5 -1/2 (140) EXHAUST AIR B IFTING BRACKETS • B / S R LIFTING BRACKET Q 3l4 (19) �' (GCS16- 0413-060) 19-3/8 (492) 1 3 -1/4 (83) 110 II 16 J (457) I-I I i . 1 � a IIII ELECTRICAL, CONDENSAT I I I 1 ;I INLETS DRAIN II I � FILTER AND FILTER RACK 141) -5/ 1 1 U 3 (76) I■ 3 (76) • (GCS16-024-030-036) ■ ■ ■ Mil 11111! HORIZONTAL _ _ SUPPLY AIR HORIZONTAL OPTIONAL STAND -OFF OPENING RETURN AIR MOUNTING KIT (6) N OPENING (Field Installed) BACK VIEW (With Horizontal Supply & Return Air) FRONT VIEW A 5/8 LIFTING BRACKET 9 1/2 A (15) (GC816-024 -030-036) ( 241, FLUE OUTLET ` r Pi ♦ I L — —�-- OPTIONAL 1 I I II i 1 JDENSL 1 I I I C _i OAD16 OUTDOOR I (Fla d Instal ed) C l COIL 1 I i C FILTER AND I i i 1? (G FILTER RACK FILTER 9 -060) K f 1 1 11 I III I11 I I I I I I ti- _ ] I GAS INLET L III 1 I I I I I II 1 5 -1/2 (140) 5 -1/2 (140) OPTIONAL HF16 HORIZONTAL - --f OPTIONAL STAND-OFF MOUNTING KIT (6) FILTER KIT (Field Installed, (Field Installe Ca Only) END VIEW END VIEW Model A B C D E F G H J K Number Inch mm Inch mm inch mm inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm GCS16 -024 GCS16 -030 46 1168 60 1524 23 584 18 457 13 330 13 330 10 254 3 76 4 102 2 -1/4 57 CC:S1 -0:16 GCS16 -048 52 1321 72 -1/2 1842 29 737 22 559 18 457 22 559 7 -1/2 191 5 127 3 76 3 -3/8 86 GCS16-060 \ \ Model L M N P ['P 0 R ['S T ['T lr Number Inch mm Inch mm Inch mm Inch mm In. mm Inch mm Inch mm Inch mm inch mm Inch mm J GCS16 -024 GCS16 -030 10 -5/8 270 2 51 26 -3/4 679 5 127 6 152 20 -5/16 516 4 -1/8 105 22 559 13 -3/4 349 14 -1/2 368 l;C:C1R -0 A GCS16 -048 13 -1/8 333 5 127 28 711 8 203 6 152 19- 3/16 487 3/4 19 27 686 13 -3/4 349 18 -5/8 473 GCS16-060 ['Canada Only GCS16 -2 to5 Ton / Page 16►