Loading...
Specifications I • � o Qo 47ti e'z mo o . o R Q' 4' 1 I e'O Western States 47s, co I Fire Protection Co. I 13896 Fir Street Suite B Oregon City, OR 97045 Phone (503) 657 -5155 Fax (503) 657 -5182 I I Fire Protection Submittal I titk 67___o V.46 • City of Tigard i America's Tire A • . • ve • Plans By /'*"-� r Date � 11462 SW Pacific Hwy. CS I ���� W Tigard, Oregon 97223 puP2c - t 33 1 WSFP Job No. LC0016 • Prepared by: Darrell T. Fluit III Project Manager OFFICE COPY 1 Western States Fire Protection Co. 13896 Fir Street Suite B 1-■I -wro 41 O Oregon City, OR 97045 , 1.-.: i - �s Phone: (503) 657 -5155 �J� �O ��7 f'- Fax: (503) 657 -5182 �G 1 , Email: darrell.fluit(a�wsfo.us i Web: www.wsfp.com j '`i April 1, 2008 I I I I Bulletin 136 Rev.M Model F1 F I Model F1 FR Recessed 5. Quick Response I Sprinklers 5 Model Fl FR Sprinkler Types I Standard Upright Standard Pendent ' Conventional °''i° I Vertical Sidewall Horizontal Sidewall • - HSW 1 Deflector I Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall Upright Pendent I — HSW 1 Deflector Listings & Approvals / 1. Listed by Underwriters Laboratories, Inc. (UL) I 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals , 4. Loss Prevention Council (LPC, UK) 5. NYC BS &A No. 587 -75 -SA I 6. Meets MIL- S -901C and MIL -STD 167-1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Vertical Sidewall Conventional I Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV 1 • . . ". • Patents: US Patent No. 6,374,920 Applies to � - I Model Fl FR Vertical Sidewall Sprinklers. I Product Description Horizontal Sidewall Recessed Pendent Reliable Models Fl FR and Fl FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative I sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to utilize a 3.0 mm frangible glass bulb. These sprinklers have push out against the bulb, causing the glass to shatter, demonstrated response times in laboratory tests which are opening the waterway and allowing the deflector to distrib- ' five to ten times faster than standard response sprinklers. This ute the discharging water. quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard Application sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- ' The glass bulb consists of an accurately controlled amount tion systems: Wet, Dry, Deluge or Preaction. Care must be o f special fluid hermetically sealed inside a precisely manu- exercised that the orifice size, temperature rating, deflector factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. ciation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble. As heat is applied, the liquid ex- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 I I Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers I Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Approval Sprinkler Identification I Standard - Upright (SSU) and Pendent (SSP) US Met Number (SIN) Deflectors Marked to Indicate Position Height Organization SSU SSP y," (15mm) Standard Orifice with y" NPT (R}2) Thread 5.6 80 2.2" (56mm) 12,3,4,5,6,7 R3625 R3615 %," (20mm) Large Orifice with X" NPT (R /a)Thread 8.0 115 2.3" (58mm) 12,3,4,7,8 R3622 R3612 I % I (17mm) Small Orifice with};" NPT (R}2) Thread 4.2 60 2.2" (56mm) 1,2,8 R3623 R3613 X" (10mm) Small Orifice with};" NPT (R}2) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R %" Thread 4.2 60 56mm 4,6,7 R3624 R3614 I Conventional - Install in Upright or Pendent Position 10mm Orifice XLH with R % Thread 4.2 60 56mm — R3674 15mm Standard Orifice with }2" NPT (R}2) Thread 5.6 80 56mm 4,6,7 R3675 20mm Large Orifice with 3 /4" NPT (R3)Thread 8.0 115 58mm 4,7 R3672 I / ,; * :-.--:-.'' •-• .,, Mik. ( I - . 11 . II . ill I , Upright Pendent Conventional 1 Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench 1 Installation Data: Nominal Thread K Factor Sprinkler A f p Approval Sprinkler Identification I 'Orifice Size US Metric Height Organizations Number (SIN) }2" (15mm) y" NPT (R 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 ' %2I (20mm) X" NPT (R /) 8.0 115 2.3" (58mm) 1,2,3,8 R3612 T (11mm) }2" NPT (R1) 4.2 60 2.2" (56mm) 1,2,8 R3613 1 X" (10mm) }2" NPT (RY2) 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm R% 4.2 60 56mm 4,7 R3614 (') Refer to escutcheon data table for approvals and dimensions. - I • � 4 7 r /A' HOLE Ou. �— 2 5 /B DIA. (66.7mm) -a. (372m - HOLE IN CEILING +_ 7 ?5/16' DM 2 5/76" DIM. f58.7mm_1 -� I /AV 2 "J CUP = = L = _ � -- = = v_�, r C r 7/2' REDUCER I I I ,..— I" X I/2" REDUCER TURN C y- UNRL TIGHT I l I AGAINST SPRINirLCR WRENCH BOSS -\\ 1 I / I I �/ ANL s 4 - _ FACE OF !MING TO N L _ J - -- 1 AOIUS 11) 6 jj CEILING DIMENSION CEILING =� - _ �� _��� 1 _j 0 0 ba , FACE OF rlmnlG �- - U , ro FACE OF CEILING 7/8 1 L. , ` I DIMENSION ) 0 .2minl -A,' ' � t01 11 I (1 •A•• (I) 2 27/77 (MA ADJUSTMENT J _ (72.2 » j - , 136PG0!_E ` _ I __ 1 1.5E'0S -A (I) REFER 70 Fl k F7 ESCUTCHEON DATA TAME FOR APPROVALS ANO DIMENSIONS. (I) REFER 10 PP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. I 2. . 1 ,' • Model Fl FR Quick Response Vertical Sidewall Sprinkler I Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval.Type: Light Hazard Occupancy I Installation Data: Nominal Thread K Factor Sprinkler , Sprinkler Identification , Orifice.; Size US . ' Metric . Height rganizations Number (SIN Number (SIN) 15mm '/2" NPT (R'/2) 5.6 80 2.2" (56mm) .1, 2, 3, 6, 8 R3685 15m , 1/2" NPT (RY) 5.6 80 2.2" (56mm) 4 11) I (1) LPC Approval is for Pendent position only. Deflector to Ceiling ,, i: ‘ _ 3. Orientation Dimension (Min. -Max.) 111 _ Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) I Vertical Sidewall . US Patent No. 6,374,920 . • Model F1 FR Quick Response Horizontal Sidewall Sprinkler I Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: ' Approval Organizations K Factor and Type of Approval Sprinkler Identification Nominal Thread Sprinkler Light Ordinary Number (SIN) • I • Orifice Size US Metric Length Hazard Hazard • }2" (15mm) X" NPT(R1/2) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 • I NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. 136rco4 // /Z <�L .2 .-- - - - - -- O rAcr or FIFIINC TO Ir - 1111 .. - v WALL DIMENSION �_ -_ I 1/4 MIN. [31. Ernm) I C., r•.. of -2 1/4" HOLE DN. _-' _ /R , �", yz n'.-., i [57.2mml ' � [ 101.Emm- 152.4mm) Hit ' ;O : S � (/7 , l 1 [J.2mm) CEILING TO I \ ' , = A. 1' X I /2" REDUCER - I DEFLECTOR / I ' } 1 _ _ - - -1 I Horizontal Sidewall — t 11 e 27/J2 DIM. (49.2mm> i r��1�r,t l_ [72.2mmf Nil L_ - TURN COLLAR UNIIL --� 1 ' I --"-- --1— TIGHT AGAINST SPRINKLER L WRENCH ROSS. hr L AWUSIMENI 1 I (I) REFER TO ESCUW ICEON DATA !ABLE FOR APPROVALS AND DIMENSIONS. . 3. I Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- ' specified in NFPA 13. Quick response sprinklers and stan- tie vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any The Model Fl FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers. should be maintained to be installed as shown. The Model Fl or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- I trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained Model Fl FIR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini - eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would , When installing Model Fl FR Sprinklers, use the Model D Sprin- cause improper operation or non - operation. kler Wrench. When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these sprinklers. Standard Upright I Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent I nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes ") (2) 1 TO REMOVE THE PROTECTORS. Standard Finishes Temperature Ratings Sprinkler Escutcheon Bronze Brass Sprinkler Max. Ambient Bulb Chrome Plated Chrome Plated (3) I Classification Temperature Temp. Color White Polyester Coated White Painted (3) °C °F Ordinary 57 135 100°F (38°C) Orange Special Application Finishes Ordinary 68 155 100F(38°C) Red Sprinkler Escutcheon I Intermediate 79 175 150°F(66°C) Yellow Bright Brass Bright Brass Intermediate 93 200 150°F(66°C) Green High (t) 141 286 225°F (107°C) Blue Black Plated Black Plated Black Paint Black Paint I (1) Not available for recessed sprinklers. on White Off White Escutcheon Data Satin Chrome Satin Chrome Face of FItll (t) Other finishes and colors are available on special order. Escutcheon "A" Approvals Adjustment Dimension toCeiltrtgor Consult the factory for details. model I wall Dimension ( FM Approvals is limited to bronze and brass, chrome or black 1 ^ plated finishes only. Max Recess (38.1mm) Xs' - ' %.' (3) FP Push - on/Thread -off escutcheon Fl 1,2,4,8 Min Recess X " (5mm - 24mm) (19.1mm) Ordering Information I Y Specify: F2 1,2,3,4,5,7,8 Max Recess (38.1mm) ' X,.' Min Recess 'g; (5mm -17mm) 1. Sprinkler Model (24mm) 2. Sprinkler Type I FP 1,2 Max Recessed '1e' 1y' (38.1mm) 3. Orifice Size Push-on/ (11 mm) Thread-off 1,2 Min Recessed 15 1 " (25.4mm) 4. Deflector Type (24mm) 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish I 7. Escutcheon Type Maintenance 8. Escutcheon Finish (where applicable) The Models F1FR and F1FR Recessed Sprinklers I should be inspected quarterly and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research , Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by us rieliabla The Reliable Automatic Sprinkler Co., Inc. ® R P e (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax Revision lines indicate updated or new data I (914)668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 7/05 P/N9999970027 1 I Bulletin 117 Rev. 1 Model F1 ® Model F1 Recessed 5 Standard Response Sprinklers D The Designer Model Fl Sprinkler Standard Upright Standard Pendent di Extended Coverage Pendent i Conventional = 1 r Vertical Sidewall \. � Horizontal Sidewall - -- — HSW1 Deflector - r The Designer ® 11 Model Fl Recessed Sprinkler Upright Pendent • Recessed Pendent _ - Recessed Extended / ded Coverage Pendent - -\ • I Approval Organizations tv 1. Underwriters Laboratories Inc. ! , - I 2. Underwriters' Laboratories of Canada - I 3. Factory Mutual Research Corp. 4. Loss Prevention Council • . 5. NYC BS &A No. 587 -75 -SA 6. Pleniere Assembles Vertical Sidewall Conventional I 7. Verband der Schadenversicherer 8.`NYC MEA 258 -93 -E UL Listing Category c o 1 II Sprinklers, Automatic & Open (VNIV) t'771.11 � • 1 i Patents: U.S. Patent No. 6,374,92 _ '- Applies to Model Fl Vertical Sidewall Sprinklers. I Product Description Horizontal Sidewall Recessed Pendent The Fl Glass Bulb Sprinkler combines the durability I of a standard sprinkler with the attractive low profile of �: a decorative sprinkler. Whether installed on exposed f. "" , _ piping or in an office ceiling, it is functional and ( :4 ' ' ► attractive. The Horizontal and Vertical Sidewall I Sprinklers provide an equally attractive appearance kg � `� when ceiling piping cannot be used. Beautifully versatile is the description for the Reliable Model Fl Recessed Designer glass bulb sprinkler. Extended Coverage Recessed Extended I Recessing The Designer enhances its already low Pendent Coverage Pendent profile decorative appearance, and facilitates a rapid and perfect installation. At normal temperatures, the glass bulb contains the Model Fl Recessed Designer's escutcheon is highly fluid in both the liquid phase and in the vapor phase. adjustable. The two piece construction makes field The vapor phase can be seen as a small bubble. As installation a very easy and rapid task. This also allows heat is applied, the liquid expands forcing the bubble ceiling panels to later be removed without shutting smaller and smaller as the liquid pressure increases. I down the fire. protection system, thus facilitating Continued heating forces the liquid to push out against maintenance of above ceiling services. the bulb, causing the glass to shatter, opening the The Designer Automatic Sprinkler utilizes a frangible waterway and allowing the deflector to distribute the glass bulb. The glass bulb consists of an accurately discharging water. I . controlled amount of special fluid hermetically sealed The Fl Sprinkler temperature rating is identified by inside of a precisely manufactured glass capsule. This the color of the glass bulb capsule as well as frame glass bulb is specially constructed to provide fast color where applicable. thermal response. I The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York, 10523 I Model Fl Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench T 1 >. t i ,,,;:,,,,....,....,_ .,, �.4 _ 1 - i "s I Upright Pendent Conventional I Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler Identifi Numbers Thread Size SI Orifice Height Organization US Metric Upright Pendent Standard - Upright (SSU) and pendent Deflectors Marked to Indicate Position %z' '' /z' NPT 5.6 80 2.2' 1,2,3,4,5,6,7 R1 i25 R1715 I (15mm) (R1/2) (56mm) 17/32' ' NPT t 8.0 115 2 ' 3 1,2,3,4,7,8 R1722 R1712 (20mm) (R3/4) (58mm) (15mm) ` (R1/2) 5.6 80 (56mm) 7 I 17/32' 'X NPT 2.3' (20mm)j (R3/4) 8.0 115 (58mm) 7 7/16' /z' NPT 2.2' 4.2 60 1,2,8 R1723 R1713 (11mm) (R1/2) (56mm) 3/8' Yz' NPT 2.8 40 2.54' 1,2,8 R1721 R1711 (10mm) (R1/2) (65mm) 10mmXLH R3 /8 4.2 60 56.1rrim 4,6,7 R1724 R1714 Conventional- Install in Upright or Pendent Position 10mmXLH R3/8 4.2 60 56.1mm ' R1774 15mm 1/2' NPT 5.6 80 56:1mm 4,6,7 R1775 20mm' NPT 8.0 115 58.1mm 4,7 - R1772 (R3/4) I (1) LPC Approval up to 286 °F (141 °C) (2) FM Approval for SSU up to and including 200 °F (93 °C) only. _ I (3) (F1pvdan5 °F (68 °C) only. (4) Polycoated S5) VdS upright ro al UL for and ULC Interme listed i te Respo corrosion se resistant. 15 I • 1 I I 2. i I. Model Fl Recessed Pendent Sprinkler I . I Installation Wrench: Model GFR1 Sprinkler Wrench [571mm] 1 15/16' OK 1 [�9.2mm) 1' X I /2' REDUCER • �, TURNCOL[AR [25.Imm X 12.7mm) UNTIL TIGHT 1 •� ' WRENCH BOSSKLCR i^ II I ^' it.--- , 1 r °= - I I , 1 , LL ��s� L_ J 15/16" Recessed Pendent /4' AOJUSIN£M n' (I) [2 .1.emmJ . ( 18.1 1 1 % / /// P, I [! hnm) 1' [25.Imm) 135FGOIA 117FGOIA 2 27/!2' GIA. [71.1mm) (1) When installed directly into a tee, the escutcheon dimension's adjustment will be reduced. I Installation Data: Nominal Thread Size Nominal K Factor Sprinkler Height Approval Sprinkler Identification Orifice US Metric Organization Numbers (SIN) I 1/2' 3 h' NPT 2.2' 5.6 80 1,2,3,4,5,7 R1715 (15mm) (R1/2) (56mm) 1 7/32' 3 /°' NPT 8.0 115 2 ' 3 1,2,3,4,8 R1712 (20mm) (R3/4) (58mm) W 1/2' NPT 5.6 80 2.2' . (15mm) (R1/2) (56mm) 17/32' ' /°' NPT 2.3' 7 (20mm) (R3/4) 8.0 115 (58mm) 7 • • • 7/16' . ' /z' NPT 4.2 60 2.2• 1,2,8 R1713 • E (11mm) (R1/2) (56mm) ` 3/8' h' NPT 2 2.8 40 ' 1,2,8 R1711 (10mm) (R1/2) (56mm) 10mm R3/8 • 4.2 60 56.1mm 4,7 R1714 (2) FM Approval • Light Hazard - No Limitations . . • Ordinary Hazard - Groups 1 & 2, Wet Systems only. I (3) LPC Approval is for 57 °C through 93 °C ratings. (4) VdS Approval for Intermediate Response 155F (68 °C) only. I I, 1 .1 I. . • 3. I Model Fl Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy . i U.S. Patent No. 6,374,920 -- Sprinkler Type Deflector to Ceiling Distance • Z (Min. - Max.) t Upright 4' (102mm) - 12' (305mm) Vertical Sidewall I Pendent 4' (102mm) - 12' (305mm) • Installation Data: T Nominal K Factor Sprinkler Nominal Orifice Thread Size US Metric S Helght r Organizations Identification Numbers (SIN) '// (15mm) Y' NPT (R1/2) 5.6 8.0 2.2' (56.1mm) 1,2,3,4,6,8 R1785 (1) LPC Approval is pendent only, 57 °C through 141 °C ratings. I Model Fl Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench .,......,,, 1 •1/16'-5/15" [Smm -14mmJ 1 I /4' MIN. 2 1/4' HOLE DM (J 1.8mm) 4_ -6 (57.2mm) 1 /8; (101.6mm- 152.4mmJ (l.2mmJ CEILING T° '." - s, \ DEFLECTOR ''- - =—!: I' X I /2' REDUCER 1 + 01:1 ,, _�I I 'I - —- II ..,a' Imp j ' t 7 15/76' DU. ,!u�II i 1 J' [49.2 wnJ i -- l l ;r,' :� 2 27/32 Dd. �1 �l r ( — L TURN COLLAR UNDL LA N I TIGHT AGAINST SPRINKLER \ WRENCH 8°55. 3/4' (19mrn) Horizontal Sidewall I I7f4V.M ADJUSTMENT • Installation Data: I Nominal K Factor Approval Organizations Sprinkler Nominal Thread Size Sprinkler Identification Orifice US Metric Height Light Hazard Ordinary Numbers SIN Hazard (SIN) h' (15mm) '�RNP; 5.6 80 2.63' (67mm) 1,2,3,5 1,2,5 R1735 Note: UL and ULC Listing permits use with Fl escutcheons, light hazard only. I • 1 4. 1 I I Model Fl Extended Coverage Pendent Sprinkler Deflector: EC Pendent ' .. , Installation Wrench: Model D Sprinkler Wrench Approval Type: Extended Coverage - Light Hazard Occupancy m `t va I y ' 7 Coverage Area T Pressure ` Flow Rate Nominal Width x Length �, Max. Area \� �. : T. I K =8.0 (115) K =5.6 (80) .. r _ "`, gpm Umin psi bar ' psi bar ft. x ft. m x m II 26 98.4 10.6 0,7 21.6 1,5 16 x 16 4.9 x 4.9 Extended Coverage Pendent — 33 125.0 17.0 1,2 34.7 2,4 18 x 18 5.5 x 5.5 g 40 151.4 25,0 1,7 51.0 3,5 20 x 20 6.0 x 6.0 I Installation Data: Nominal K Factor Temperature Rating Sprinkler Nominal Thread — Sprinkler Approval Identification Orifice Size US Metric Height Organizations °F °C Numbers (SIN) • I 17/32' 3 /a' NPT 8.0 115 2.2' (56mm) 1,2,8 135,155 57, 68 R1742 (20mm) (R3 /4) 1/2' (15mm) ( N2; 5.6 80 2.2' (56mm) 1,2,8 135, 155 57, 68 R1745 Model Fl Recessed Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model GFR1 Sprinkler Wrench 2 r,.• MOLE a. Approval Type: Extended Coverage - Light Hazard Occupancy (5 """' -1 1916; DM 19 II L - d 1 _ '° - • x ,/c REDUCER xs 4 7 I [ xmm r P. rmm] • TURN COLLAR f I I ;;12, I / R(DUCFR M WIT 1 m r r9.)mmJ 1 / : 7;7,7 I 1 i L J ` � . `/ / u• ar r, t c I� zramm (19. r.,.1 ) r9 ;mm, III/LV]A 2 27 /i2 a'. (72.2m.) I Extended Coverage Recessed (1) When installed directly into a tee, the escutcheon dimension's adjustment will be reduced. I Coverage Area Pressure Flow Rate Nominal Max. Area Width x Length • K=8.0 (115) K =5.6 (80) gpm L./min psi bar psi bar ft. x ft. m x m 26 98.4 10.6 0,7 21.6 1,5 16x16 4.9x4.9 33 125.0 17.0 ' 1,2 34.7 2,4 18 x 18 5.5 x 5.5 40 151.4 25,0 1,7 51.0 3,5 20 x 20 6.0 x 6.0 I Installation Data: ' Nominal K Factor Temperature Rating Sprinkler Nominal Thread Sprinkler Approval Identification I Orifice • Size US Metric Height Organizations °F °C Numbers (SIN) 17/32' 3 / < <' NPT 8.0 115 2.2' (56mm) 1,2,8 135, 155 57, 68 R1742 (20mm) (R3/4) 1 1/2' (15mm) ( R1/2) NPT 5.6 80 2.2' (56mm) 1,2,8 135, 155 57, 68 R1745' ( 5. Model Fl & Fl Recessed Sprinklers Ordering Information I Application Specify: Model Fl and Fl Recessed sprinklers are used in 1. Sprinkler Model fixed fire protection systems: Wet, Dry, Deluge or 2. Sprinkler Type Preaction. Care must exercised that the orifice size, 3. Orifice Size I temperature rating, deflector style and sprinkler type 4. Deflector Type are in accordance with the latest published standards 5. Temperature Rating of the National Fire Protection Association or the 6. Sprinkler Finish I approving Authority Having Jurisdiction. 7. Escutcheon Finish (where applicable) Installation Temperature Ratings Model Fl sprinklers are standard response sprinklers Maximum intended for installation as specified in NFPA 13. They Sprinkler Ambient I must also be installed with the Model D Sprinkler classification Temperature Temperature Colo Wrench specifically designed by Reliable for use with °F °c °F °C these sprinklers. Ordinary 135 57 100 38 Orange The Model Fl Recessed Sprinklers are to be installed Ordinary 155 68 100 38 Red I with a maximum recess of 3 /4 inch (19mm). The Model Intermediate 175 200 150 66 150 Yellow Green Fl Escutcheon illustrated is the only recessed Hight" 286 141 225 107 Blue escutcheon to be used with the Model Fl Pendent and Extra Hight" 360 182 300 149 Mauve EC Sprinklers. The use of any other recessed (1) Not Available for F1 Recessed I escutcheon will void all approvals and negate all w iz, i Re . ,, endent arranties. an d When EC Pendent nstalling Sprinklers Model , use F1 the me Applies Patents: to U. Model S. Patent F1 Vertical No. 6374 Side wall Sprinklers. GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Finishes Glass bulb sprinklers have orange covers to protect' Standard Finishes the bulb during the installation process. REMOVE THIS Sprinkler Escutcheon PROTECTION ONLY AFTER THE SYSTEM HAS BEEN H I YDROSTATICALLY TESTED AND, WHEN APPLICABLE, Bronze Brass Chrome Chrome THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO White Polyester Coated" White Painted wrenches are designed to install sprinklers when Special Application Finishes I covers are in place. Sprinkler Escutcheon Maintenance . Bright Brass Bright Brass Black Plated Black Plated The Models Fl and Fl Recessed Sprinklers should Black Paint Black Paint be inspected quarterly and the sprinkler system Off White Off White I maintained in accordance with NFPA 25. Do not clean Le Lead Pllated d Chrome ") Satin Chrome sprinklers with soap and water, ammonia or any other Wax Coated"" cleaning fluid. Remove any sprinkler which has been Wax Over Lead painted (other than factory applied) or damaged in any (1) Other colors and finishes are available on special order. Consult way. A stock of spare sprinklers should be maintained factory for details. • to allow quick replacement of damaged or operated (3) UL and C listed, and NYC approved only. sprinklers. Prior to installation, sprinklers should be (4) 155°F to 200 °F (68 °C to 93 °C) ratings only. maintained in the original cartons and packaging until (5) 286 °F (141 °C) sprinklers may be coated for ambient conditions not used to minimize the potential for damage to sprinklers (6) UL and 1 LC listed c p g p (6) UL and ULC listed corrosion resistant SIN numbers: R1721, R1722, that would cause improper operation or non - operation. R1723 and R1725. Note: For 1/2" orifice pendent FM approved white I polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 013. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, I Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. I Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled Paper Reliable (800) 431-1588 Sales Offices (800) 848 -6051 (914) 829-2042 Sales Fax Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G. Printed in U.S.A. 3/07 P/N 9999970011 1 , I I . tyco Fire & Building I Products I Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 I Model ESFR -25 Early Suppression Fast Response Pendent Sprinklers 25.2. K- factor I ing or eliminating the need for a sys- General • tern fire pump. Also, the Model ESFR- 25 permits use of a maximum deflec- - Description for -to ceiling distance of 18 inches (460 mm) versus 14 inches (360 mm); The. Model ESFR -25 Pendent Sprin- and, a storage arrangement of 40 ft. — klers (Ref. Figure 1) are "Early Sup- (12,2 m) with a ceiling height of 45 ft. pression Fast Response Sprinklers" (13,7 m) does not require in -rack sprin- _ L l , I having a nominal K- factor of 25.2. klers as do ESFR sprinklers having a i !. , They are suppression mode sprinklers nominal K- factor of 14.0. that are especially advantageous as a �_ means of eliminating the use of in -rack Applications for the Model ESFR -25 1 l' I sprinklers, when protecting high -piled Sprinklers are expanding beyond the storage. current recognized installation stand- III ards. For information regarding re - The Model ESFR -25 is primarily de- search fire tests which may be accept - signed for use with storage heights of able to an Authority Having I most encapsulated or non - encapsu- Jurisdiction (e.g., flammable liquids, lated common materials including car- exposed plastics, and aerosols), o + * } ; , ,, toned unexpanded plastics to 40 ft. please contact the Technical Services (12,2 m) high and with ceiling heights Department. • C 45 ft. (13,7 m). In addition, the pro - Ito tection of some storage arrangements WARNINGS of rubber tires, roll paper, flammable The Model ESFR - Sprinklers de- liquids, aerosols, and automotive com- scribed herein must be installed and II ponents can be considered as well. maintained in compliance with this The ESFR - 25 provides the system de document, as well as with the applica- signer with hydraulic and sprinkler ble standards of the National Fire Pro - placement options not presently avail tection Association, in addition to the 1 able to the traditional ESFR sprinklers standards of any other authorities hav having a nominal K- factor of 14.0. In ing jurisdiction (e.g., FM Global). Fail - • particular, the Model ESFR -25 has ure to do so may impair the perform- been designed to operate at substan- ance of these devices. ' tially lower end head pressures, as The owner is responsible for maintain- compared to ESFR sprinklers having a ing their fire protection system and de- nominal K- factor of 14.0. This feature vices in proper operating condition. offers flexibility when sizing the sys The installing contractor or sprinkler tern piping, as well as possibly reduc manufacturer should be contacted I with any questions. • IMPORTANT Sprinkler Always refer to Technical Data I Sheet TFP700 for the "INSTALLER Identification WARNING" that provides cautions with respect to handling and instal- Numbers lation of sprinkler systems and com- I ponents. Improper handling and in- SIN TY9226 - (Pendent K =25.2) stallation can permanently damage TY9226 is a redesignation for C9226, a sprinkler system or its compo- G8441, and S8010. nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. I Page _1 of 8 JUNE, 2007 TFP312 II Page 2 of 8 TFP312 1 7 y f 1 ° NPT 1- 13/16" 9/16" 111111Ir 1 -Frame y 8 � r� (14,3 mm) (46,0 mm) 2- Deflector g r■`Q�H�II2Q:: NOMINAL - 1 3- Compression' Screw 7� 4 -Hook MAKE -IN ■ � ■ 1 5 -Strut 6 . ' , 6 -Link Assembly i 3- 13/16° 7 I -Button (96,8 mm) THERMAL 8- Sealing Assembly 5 I 9- Ejection Spring ■ WRENCH ELEMENT 4 j SENSING FLATS c c 3 ilk ATI 2 III TEMPERATURE I RATING 1 2" (50,8 mm) --- FIGURE 1, MODEL ESFR -25 EARLY SUPPRESSION FAST RESPONSE PENDENT SPRINKLER I guidelines are not intended to provide Technical Design Criteria complete installation criteria. Data NOTE The National Fire Protection Associa- GENERAL GUIDELINES Approvals tion (NFPA) and FM Global (FM) pro - UL and C -UL Listed. FM and VdS Ap- vide installation standards that must System Type: Wet pipe system. 11 proved. LPCB Approved (094b/01 & be used to properly design an auto Roof Construction: Unobstructed or 0071/01). NYC under MEA 356 -01 -E. matic sprinkler system utilizing Early obstructed construction. For example: Maximum Working Pressure Suppression Fast Response (ESFR) smooth ceiling, bar joists, beam and 175 psi (12,1 bar) Sprinklers. The guidelines provided by girder, etc. I NFPA and FM may differ; conse- Pipe Thread Connection quently, the appropriate standard must NOTE 1 inch NPT or ISO 7 - R1 be used for a given installation. Where the depths of the solid struc- 9 The following data sheets d escribe the tural members (beams, stem, etc.) ex - Discharge Coefficient ( ) K = 25.2 GPM /psi / ESFR Sprinklers offered by Tyco Fire ceed 12 inches (302 mm), ESFR (362,9 LPM /bar Products: Sprinklers shall be installed in each channel formed by the structural mem- Temperature Ratings TFP312 — Model ESFR -2 (TY9226), bens. 165 °F /74 °C or 214 °F /101 °C K =25.2 Pendent Sprinkler Ceiling Slope: Maximum 2 inch rise 1 Finish TFP315 — Model ESFR -17 (TY7226), for 12 inch run (16.7 %). Natural Brass K =16.8 Pendent Sprinkler Building Heights, Storage Heights, Physical Characteristics TFP316 — Model ESFR -17 (TY7126), and Commodity: Refer to Table A. Frame Brass K =16.8 Upright Sprinkler Maximum Coverage a Area: I Deflector Bronze TFP318 — Model ESFR -1 ( ) TY6226 , 100 ft (9,3 m . In some cases, the Compression Screw ( ) Stainless Steel K =14.0 Pendent Sprinkler installation standards permit a greater Hook Monel The followin g general guidelines pro - coverage area. 1 Strut Monel vided for ESFR Sprinklers offered by Minimum Coverage Area: Link Assembly : . . . Solder, Nickel Tyco Fire Products may be used for a 80 ft (7,4 m per NFPA 13, and Button Brass quick reference to help select the ap- 64 ft (5,8 m per FM 2 -2 Sealing Assembly propriate Tyco Fire Products' ESFR Beryllium Nickel w/Teflon* Sprinkler: Maximum Spacing: 12 feet (3,7 m) for Ejection Spring Inconel building heights up to 30 feet (9,1 m), and 10 feet (3,1 m) for building heights *Registered trademark of DuPont. NOTE greater than 30 feet (9,1 m). In all cases, the appropriate NFPA or Minimum Spacing: I Patents FM installation standard must be refer- 8 feet (2,4 m). U.S.A. Patent Numbers: enced to assure applicability and to 4,580,729 5,829,532 obtain complete installation guide Minimum Clearance To Commodity: 6,059,044 6,336,509 lines, since the following general 36 i nches (914 mm). 6,502,643 7,165,624 1 Patents pending. I I TFP312'� Page __3_of 8: TABLE A , . BUILDING HEIGHTS, STORAGE HEIGHTS, AND,COMMODITY . (See Design Criteria Section) Open frame (i.e. no solid shelves) single, • double, multiple-row, "or portable rack See Table A -1 ' • storage of Class I-- IV and Group A or B , (Refer to NFPA 13 or FM 8-9 and 2 -2. plastics '•• • for details) I Solid pile or palletized storage of Class I - IV and Group A or. See Table A =2 • • (Refer to NFPA 13 or FM 8 -9 and 2 -2 for details) I Idle pallet storage See Table A -3 . . . " , (Refer to NFPA 13 or FM 8 -24 and 2 -2 for details) Rubber Tire Storage See Table A=4 - - . , (Refer to NFPA 13 or FM 8 -3 and 2 -2 I for details) • Comparison to Other TFP ESFR Sprinklers • ESFR -25 ESFR -1 ESFR -17 ESFR -17 PENDENT PENDENT PENDENT UPRIGHT • K =25.2 K =14.0 K =16.8 K =16.8 See Data Sheet See Data Sheet See Data Sheet I . TFP318 TFP315 TFP316 NFPA FM NFPA FM NFPA FM NFPA FM Rolled Paper Storage (See Standard) 13 8-21 13 8 -21 13 — — 8 -21 I Flammable Liquid' Storage (See Standard) 30 — 30 7 -29 — — — — Aerosol Storage (See Standard) 30B 7 -31 30B 7 -31 30B — — —• Automotive Components in Portable Racks 13 — — — — — — — (Control Mode Only, See Standard) I NFPA 13 — Deflector To Ceiling FM 2 -2 — Deflector To Ceiling FM 2 -2 — Thermal Sensing Element Distance: Distance: To Ceiling Distance: ESFR -25 (K =25.2) Pendent: ESFR-1 (K= 14.0) Pendent: ESFR -25 (K =25.2) Pendent: I 6 to 18 inches (152 to 457 mm). 5 to 14 inches (121 to 356 mm). 4 to 18 inches (102 to:457 mm). ESFR -1 (K =14.0) Pendent: ESFR -17. (K =16.8) Pendent: ESFR -1 (K =14:0) Pendent: 6 to 14 inches (152 to 356 mm). 5 to 14 inches (121 to 356 mm). 4 to 13 inches (102 to 330 mm). I ESFR -17 (K =16.8) Pendent: ESFR -17 (K= 16.8)_Upright: ESFR -17 (K =16.8) Pendent: 6-to 14 inches (152 to 356 mm). 5 to 14 inches (121 to 356 mm). 4 to 13 inches (102 to 330 mm) . ESFR -17 (K =16.8) Upright: • 4 to 13'inches (102 to 330 mm). I • . I I Page 4 of 8 TFP312 I TABLE A -1 RACK STORAGE I (See Design Criteria Section) • Commodity Maximum Maximum Minimum Flow Pressure, PSI (BAR) I Building Storage Height, Height, Comparison to Other TFP ESFR Sprinklers Feet Feet ESFR -25 ESFR -1 ESFR -17 ESFR -17 (m) (m) PENDENT PENDENT PENDENT UPRIGHT I K =25.2 K =14.0 K =16.8 K =16.8 See Data Sheet See Data Sheet See Data Sheet TFP318 TFP315 TFP316 NFPA FM NFPA FM NFPA FM NFPA FM Class I, 45 40 40 50 90* 90* 63* 63* _ - Class II, (13,7) (12,2) (2,8) (3,4) (6,2) (6,2) (4,3) (4,3) Class III, and 40 35 25 40 75 75 52 52 _ _ Class IV (12,2) (10,7) (1,7) (2,8) (5,2) (5,2) (3,6) (3,6) Encapsulated or 35 30 20 30 75 75 52 52 _ 52 Unencapsulated (10,7) (9,1) (1,4) (2,1) (5,2) (5,2) (3,6) (3,6) (3,6) -and- 32 25 20 30 60 60 42 42 42 1 - Cartoned (9,7) (7,6) (1,4) (2,1) (4,1) (4,1) (2,9) (2,9) (2,9) Unexpanded Plastics 30 25 15 20 50 50 35 35 - 35 (9,1) (7,6) (1,0) (1,4) (3,4) (3,4) (2,4) (2,4) _ (2,4) I Uncartoned 45 40 - 90* 90* 63* 63* (Exposed) (13,7) (12,2) (6,2) (6,2) (4,3) (4,3) Unexpanded 40 35 _ 50 75 75 52 52 - Plastics (12,2) (10,7) _ (3,4) (5,2) (5,2) (3,6) (3,6) _ - 1 32 25 ' 50 60 60 42 42 (9,7) (7,6) (3,4) (4,1) (4,1) (2,9) (2,9) 30 25 _ 50 50 50 35 35 - _ (9,1) (7,6) (3,4) (3,4) (3,4) (2,4) (2,4) 1 Cartoned 32 25 _ - 60 60 42 42 _ 42 Expanded Plastics ( (7,6) (4,1) (4,1) (2,9) (2,9) (2,9) 30 25 50 50 35 35 - 35 (9,1) (7,6) - - (3,4) (3,4) (2,4) (2,4) (2,4) 1 Uncartoned 30 25 - - - 100 _ - - (Exposed) (9,1) (7,6) (6,8) Expanded Plastics 25 20 _ - _ 75 - - - - 1 (7,6) (6,1) (5,2) • * One level of in -rack sprinklers is required. I 1 • 1 • I I I TFP3121, Page 5 of 8 I , TABLE A -2 1 PALLETIZED AND SOLID PILED STORAGE: (See Design Criteria Section) Commodity Maximum Maximum Minimum Flow Pressure, PSI (BAR) Building Storage Height; Height, Comparison to Other TFP ESFR-Sprinklers Feet Feet - ESFR -25 ESFR -1 ESER -17 ESFR -17 " (m) (m) . PENDENT PENDENT PENDENT UPRIGHT " K = 25.2 K = 14.0 K =16.8 K= •16.8. See Data Sheet See Data Sheet See Data Sheet TFP318 TFP315 TFP316 I . FM NFPA FM NFPA FM NFPA FM Class I, 45 40 40 50 _ _ _ - - _ • Class II, • (13,7) (12,2) (2,8) (3,4) • I Class III, and- 45 35 40 50 _ 90 _ _ _ Class IV (13,7) (10,7) (2,8) (3,4) (6,2) Encapsulated or 40 35 25 40 75 - 75 52 52 _ _ Unencapsulated (12,2) (10,7) (1,7) (2,8) (5,2) (5,2) (3,6) (3,6) -and- 35 30. 20 30 75 75 52 52 _ 52 (10,7) (9,1) (1,4) (2,1) (5,2) (5,2) (3,6) (3,6) (3,6) Cartoned 32 25 20 30 60 60 42 42 _ 42 Unexpanded (9,7) (7,6) (1,4) (2,1) (4,1) (4,1) (2,9) (2,9) (2,9) I Plastics 30 25 15 20 50 50 35 35 _ 35 (9,1) (7,6) (1,0) (1,4) (3,4) (3,4) (2,4) (2,4) (2,4) Uncartoned 45 35 _ _ _ 90 _ _ _ _ I (Exposed) (13,7) (10,7) _ (6,2) - - Unexpanded 40 35 50 75 75 52 52 Plastics (12,2) (10,7) (3,4) (5,2) (5,2) (3,6) (3,6) 32 25 - 50 60 60 42 42 L ( ( ( ( (2,9) - - 30 25 _ 50 50 50 35 35 (9,1) (7,6) (3,4) (3,4) (3,4) (2,4) (2,4) - - Cartoned 32 25. _ _ 60 60 42 42 _ 42- 1 E Plastics (9,7) (7,6) (4,1) (4,1) (2,9) (2,9) (2,9) _ 30 25. 50 50 35 35 - 35 (9,1) (7,6) - - (3,4) (3,4) (2,4) (2,4) (2,4) I Uncartoned 40 25 _ 60 - _ _ - - - (Exposed) (12,2) (7,6) (4,1) Expanded Plastics 30 25 _ 60 _ 100 - - _ - I 25 20 60 75 - (7,6) (6,1) . (4,1) (5,2) - 1 1 I 1 • I I Page 6 of 8 TFP312 1 TABLE A -3 IDLE PALLET STORAGE • ( III See Design Criteria Section) Type and Maximum Maximum Minimum Flow Pressure, PSI (BAR) Arrangement Building Storage Height, Height, Comparison to Other TFP ESFR Sprinklers Feet Feet ESFR -25 ESFR -1 ESFR -17 ESFR -17 (m) (m) PENDENT PENDENT PENDENT UPRIGHT K = 25.2 K = 14.0 K = 16.8 K = 16.8 See Data Sheet See Data Sheet See Data Sheet TFP318 TFP315 TFP316 NFPA FM NFPA FM NFPA FM NFPA FM I Wood or Plastic 40 35 _ 50 75 75 52 52 - - In -rack (12,2) (10,7) (3,4) (5,2) (5,2) (3,6) (3,6) 32 25 50 60 60 42 42 -and- (9,7) _ 7) (7,6) (3,4) (4,1) (4,1) (2,9) (2,9) - - Plastic on Floor 30 25 - 50 50 50 35 35 - - (9,1) (7,6). (3,4) (3,4) (3,4) (2,4) (2,4) Wood on Floor 40 35 _ 50 75 75 52 52 _ _ (12,2) (10,7) (3,4) (5,2) (5,2) (3,6) (3,6) 35 20 50 75 75 52 52 52 (10,7) (6,1) - (3,4) (5,2) (5,2) (3,6) (3,6) - (3,6) ' 32 25 50 60 60 42 42 (9,7) ( (3, ( ( ( ( 32 20 _ 50 60 60 42 42 - 42 ( ( _ ( ( ( ( ( - ( I ■ 30 25 50 50 50 35 35 .(9,1) (7,6) (3,4) (3,4) (3,4) (2,4) (2,4) 30 20 _ 50 50 50 35 35 _ 35 (9,1) (6,1) (3,4) (3,4) (3,4) (2,4) (2,4) (2,4) 1 I I 1 I I I I TFP312 Page 7 of 8 I TABLE A-4 I RUBBER TIRE STORAGE (See Design Criteria Section) Piling Method Maximum Maximum Minimum Flow Pressure, PSI (BAR) I Building Storage Height, Height, Comparison to Other TFP ESFR Sprinklers Feet Feet ESFR -25 ESFR -1 ESFR -17 ESFR -17 I (m) (m) PENDENT PENDENT PENDENT UPRIGHT K =25.2 K =14.0 K =16.8 K = 16.8 See Data Sheet See Data Sheet See Data Sheet TFP318 TFP315 TFP316 I NFPA FM NFPA FM NFPA* FM NFPA FM On -Side or On -Tread in Palletized Portable 30 25 15 20 50 50 35 35 35 I Racks, Open Portable (9,1) (7,6) (1,0) (1,4) (3,5) (3,5) (2,4) (2,4) (2,4) Racks, or Fixed Racks without Solid Shelves — Portable On-Side Palletized — — 52 — — — I e Racc kss, Open 35 25 25 75 Portable Racks, or (10,7) (7,6) (1,7) (5,2) (3,6) Fixed Racks without Solid Shelves — — _ _ _ _ 1 Laced Tires in Open 30 25 75 52 Portable Steel Racks (9,1) (7,6) (5,2) (3,6) I On -Side in Palletized 40 25 _ — 75 _ 52 _ _ Portable Racks (12,2) (7,6) (5,2) (3,6) * UL Listed as an equivalency to K14 ESFR protection I to 30 ft.lbs. (26,8 to 40,2 Nm). Higher Operation levels of torque may distort the sprin- ^ FITTING SIDE" kler inlet with consequent leakage or TOWARDS SPRINKLER The fusible link assembly is comprised impairment of the sprinkler. Co FITTING of two link halves which are joined Step 1. The ESFR -25 Pendent S nn- I together by a thin layer of solder. p p kler must be installed in the pendent When the rated temperature is p �� �� reached, the solder melts and the two position. ' � I �� , �� link halves separate activating the Step 2. With pipe thread sealant ap- :_: ' • ` _: V — � sprinkler and flowing water. plied, hand tighten the sprinkler into I the sprinkler fitting. Do not apply pres- Installation sure to the Link Assembly, and handle WRENCH the ESFR -25 Sprinkler only by the RECESS I The Model ESFR -25 Pendent Sprin- Frame arms. klers are to be installed in accordance Step 3. Wrench tighten the ESFR -25 FIGURE 2 with the following instructions: Sprinkler using only the W -Type 1 FI TYPE I Sprinkler Wrench (Ref. Figure 2) and NOTE by fully engaging (seating) the wrench SPRINKLER WRENCH I Damage to the fusible Link Assembly on the sprinkler wrench flats. during installation can be avoided by Step 4. After installation, inspect the handling the sprinkler by the frame Link Assembly of each ESFR - 25 arms only (i.e., do not apply pressure Sprinkler for damage. In particular, to the fusible Link Assembly), and by verify that the Link Assembly and Hook using the appropriate sprinkler are positioned as illustrated in Figure wrench. Damaged sprinklers must be 1, and that the Link Assembly has not replaced. been bent, creased, or forced out of its I A leak tight 1 inch NPT sprinkler joint normal position in any way. should be obtained with a torque of 20 Damaged sprinklers must be replaced. I I Page 8 of 8 TFP312 1 Care and Limited Ordering Maintenance Warranty Procedure The Model ESFR -25 must be main- Products manufactured by Tyco Fire & When placing an order, indicate the tained and serviced in accordance Building Products (TFBP) are war- full product name. Please specify the with the following instructions: ranted solely to the original Buyer for Sprinkler Identification Number (SIN), ten (10) years against defects in mate- quantity, and temperature rating. Re- NOTE rial and workmanship when paid for fer to the Price List for complete listing Before closing a fire protection system and properly installed and maintained of Part Numbers. main control valve for maintenance under normal use and service. This Contact your local distributor for avail - work on the fire protection system that warranty will expire ten (10) years ability. it controls, permission to shut down the from date of shipment by TFBP. No affected fire protection systems must warranty is given for products or com- Sprinkler Assemblies: be obtained from the proper authori ponents manufactured by companies Specify: (specify temperature rating), ties and all personnel who may be not affiliated by ownership with TFBP natural brass, TY9226 Pendent Sprin- affected by this action must be notified. or for products and components which kler, PSN (specify). Sprinklers that are found to be leaking have been subject to misuse, improper or exhibiting visible signs of corrosion installation, corrosion, or which have 165°F/74°C P/N 58 1 must be replaced. not been installed, maintained, modi- 214 °F /1o1 °C P/N 58 - 441 - - 214 tied or repaired in accordance with ap- Automatic sprinklers must never be plicable Standards of the National Fire "Special Order" • painted, plated, coated, or otherwise Protection Association, and /or the Sprinkler Assemblies with' ISO 7/1 altered after leaving the factory. Modi- standards of any other Authorities Thread Connections: fled or over - heated sprinklers must be Having Jurisdiction: Materials found Specify: (specify temperature rating), replaced. by TFBP to be defective shall be either natural brass, TY9226 Pendent Sprin- Care must be exercised to avoid dam- repaired or replaced, at TFBP's sole kler with thread connection per ISO age - before, during, and after instal- option. TFBP neither assumes, nor 7/1, PSN (specify). lation. Sprinklers damaged by drop- authorizes any person to assume for it, other ping, striking, wrench twist/slippage, any sale of products or parts t of p old- 214 °F /1o1 C P/N 58 442 - - 214 5 or the like, must be replaced. ucts. TFBP shall not be responsible for The owner is responsible for the in- sprinkler system design errors or inac- Sprinkler Wrench spection, testing, and maintenance of curate or incomplete information sup- Specify: W -Type 1 Sprinkler Wrench, their fire protection system and de- plied by Buyer or Buyer's repre- P/N 56- 872 -1 -025. vices in compliance with this docu- sentatives. ment, as well as with the applicable In no event shall TFBP be liable, in I standards of the National Fire Protec- contract, tort, strict liability or under tion Association (e.g., NFPA 25), in any other legal theory, for incidental, addition to the standards of any other indirect, special or consequential dam - authorities having jurisdiction. The in- ages, including but not limited to labor stalling contractor or sprinkler manu- charges, regardless of whether TFBP facturer should be contacted relative was informed about the possibility of to any questions. such damages, and in no event shall It is recommended that automatic TFBP's liability exceed an amount sprinkler systems be inspected, equal to the sales price. tested, and maintained by a qualified The foregoing warranty is made in lieu Inspection Service in accordance with of any and all other warranties. ex- local requirements and /or national press or imnlied. including warranties codes. of merchantability and fitness for a nar- tiriilar purpose, This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- I tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. I TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 I I Bulletin 204T ReiiabI 'Sprinkler Emergency Cabinets 'Sprinkler Escutcheons z I •Fusible Links o 111111111111111111111111111111.111111111111111111111. .4. I Sprinkler Emergency Cabinets P 9 Y I • Model A4 Designed to carry an emergency supply of sprinklers and a sprinkler wrench. Made of light weight steel with ,...� — holes for mounting. These compact cabinets are fin - I ished in attractive red enamel and are furnished with _ _ knockouts to accommodate either 1 or 3/ sprinkler ✓ �1 r!.‘, threads. The Model A4 Cabinets are available in the fol- — 1 7 ^& - & " lowing sizes: _ _ - .._ I • 3 Capacity - For residential sprinklers in NFPA 13D and 13R systems. Model A4 5 high x 7% long x 2% deep. 3 Capacity Residential Locate wrench separately. I. • 6 Capacity Standard - For Y and % NPT standard and large orifice sprinklers. • 5 high x 14 long x 2% deep. • 6 Capacity Large - For ESFR, XLO and VELO Spprinklers. __ 6/4 high x 14 long x 3Y8 deep. / • 12 Capacity Standard - For Y and % NPT _ti ' , �__ .(} ( � I standard and large orifice sprinklers. ,� ,, 5 high x 14 long x 4 deep. -. - -�• • Model A3 Model A4 I Model A3 Cabinets are designed to carry an emergency 6 Capacity Standard supply of decorative type sprinklers and an installation wrench. They are able to accommodate 12 Reliable Models G Recessed, G1, G4, G4FR, ZX or Model B I Flush Sprinklers, and up to 6 sprinklers with a 1 adjust- able inlet. Installation Data: Size of Cabinet: 16' 6 long x 14Y4 high x 3% deep. ^ , *'" ;� ;�' I I Size of Mounting Holes: Y diameter. II/ )11 IR�t41�IP Spacing of Mounting Holes: 13Y length - 11 height. • I Ordering Information When ordering, specify Model (A4 or A3) and cabinet Model A4 . capacity size and type (Standard or Large). Sprinklers 6 Capacity Large and sprinkler wrenches are to be ordered separately. Sprinkler Escutcheons - — These escutcheons enhance the appearance of instal- lations by covering exposed fittings of automatic sprin- I kler systems that are visible beyond finished ceilings and walls. Furnished to accommodate NPT male pipe threads, escutcheons are held firmly in place by the , sprinklers. The finishes provided are decorative and in- (_i 4' ' (; j ( ' (� (k �' � I tended for indoor use. 1 Model A4 12 Capacity Standard The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 I 1 Approvals • Model HB - Two Piece There are no UL Listings or FM Approvals associated Telescoping design permits up with the Models A, B, and C one piece escutcheons or compensate 1 adjustment to ensate the Model HB two piece escutcheon. They may be used 1 p with any Reliable Sprinkler with the exception of re- for variations in the distance that cessed sprinklers which are listed together with their re- pipe couplings extend below III spective escutcheons. Refer to the appropriate ceilings. Made of steel and technical bulletins for this information. available in brass, chrome, satin nickel and off -white finishes. Diameter: 31/2 ; Depth: 2 Min, 3 Max; 1/2 and 3 /a NPT. • Model A - One Piece I Two outer lips grip the escutch- eon tightly to the sprinkler. Avail- able in steel with chrome bright Fusible Links and bronze tone plated finishes. . • Model A - Fusible Link Same as used on Model D Auto - Diameter: 3 ; Depth including matic Sprinklers; available with lips: 3 ,e ; Y NPT. or without bronze chain hooks 1 attached to each end. Temper- ature ratings of 160 °, 212 °, 280° $:* and 350° Fahrenheit. Load ca- pacity 15-40 lbs.. Link eye i ._ , • Model B - One Piece holes are Y diameter, spaced I Y,6 on center. Available in steel with satin chrome, bright chrome and brass plated and white painted - °_- -� Underwriters Laboratories finishes. Inner fingers grip tightly ` - - Listed, Guide No. JGIX. ,, to the s Also available Yom- °} for 10mm sprinklers. Diameter: 2% ; Depth: 'X ; /2 NPT. I • Model C - One Piece I Available in steel with satin chrome, bright chrome and brass plated and white painted finishes. Inner fingers grip I tightly to the sprinkler. Also CIO , available for 10mm sprinklers Diameter: 2% ; Depth: Ye ; I '/2 NPT. I The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. I Manufactured by The Reliable Automatic Sprinkler Co., Inc. . Recycled Paper remEig ( 00) 431 -1588 848 -1051 Sales Fax Sales Fax (914) 668 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinider.com Internet Address PG. Printed in U.S.A. 02/00 P/N 9999970035 I I Bulletin 208 Rev.F I MO Rebabio Sprinkler Guards 5 • Model C o I • Model D co DJ CD T I Model C Sprinkler Guards Model C Series sprinkler guards are designed to be I assembled onto installed sprinklers. They are constructed of heavy gauge wire welded to steel mounting plates and finished with zinc plating. Other 4114 finishes are available. Guards protect automatic sprinklers in locations where they are subject to I -t . '` - I physical damage. Refer to guard selection table for • listing and approval information regarding specific 1 f N I sprin and guard combinations. I All Model C guards are certified by FM Approvals. Models C -2 and C -3 also have cULus Listings. li • Model C -1 . I Model C -1 guards are used with pendent, upright, horizontal sidewall and vertical sidewall sprinklers. • Model C -2 Model D1 Sprinkler Guard I Model C -2 guards are used with pendent dry sprinklers. • Model D -1 • Model C -3 Model D -1 guards can be assembled to pendent, upright and horizontal sidewall sprinklers. I Model C -3 guards have a water shield attached. When assembled to an upright sprinkler, the • Model D -3 and D -6 combination is for upright intermediate sprinkler Model D -3 and D -6 guards have a water shield applications. attached and are assembled to upright sprinklers. I • Model C -5 Model C -5 guards are supplied with a water shield The sprinkler guard assembly is for upright intermediate level sprinkler applications. and 0-Ring which are assembled to the sprinkler • Model D -4 and D -5 I before the sprinkler is installed. The guard is then Model D -4 and D -5 guards are D -1 guards supplied installed to the sprinkler after it is installed in the with an original water shield which is threaded on (1/2") fitting. or passed over (3/4") the sprinkler inlet thread. The combination forms a pendent intermediate level I Model D Sprinkler Guards sprinkler. The Model D Series sprinkler guards are Guards and water shields are finished with zinc supplied as kits to be assembled to the sprinkler at plating. Other finishes are available upon request. the job site before sprinkler installation. The kit I consists of the guard, 1" and 3 /4" locknuts and a All Model D Guards are cULus Listed. Refer to water shield when being used as an intermediate guard selection table for listing and approval level sprinkler. The pendent intermediate has an information regarding specific sprinkler and guard 0-Ring supplied. combinations. I Each guard type is fabricated of heavy gauge Patents: wire welded to steel mounting plates and complies USA Patent Number 5,893,418 with the latest UL standards. Guards protect Applies to Model D Series Guards I automatic sprinklers in locations where physical damage can occur. Listings & Approvals Model D Series guards are also available factory 1. Listed by Underwriters Laboratories, Inc. and assembled on the sprinkler ready for immediate UL certified for Canada (cULus) I sprinkler /guard installation. Consult factory for 2. Certified by FM Approvals availability. 3. NYC MEA 258 -93 -E 4. Scientific Services Laboratories (SSL, Australia)* I * For Models C1, C2, C3 guards. The Reliable Automatic Sprinkler Co., Inc. • 525 North MacQuesten Parkway • Mount Vernon • New York • 10552 I I Model C -1 Guards I . fi r , r= LCI. ,;- Ill ' 1 ii: [ { _ ._ ' ., A 1 ~2 / SILO LLODEL G UPRIGHT SPRINKLER -SHOWN MOQEL 0 PENDENT SPRINKLER i 208078 Model C -2 Guards I i -. _. Calliii. 1 J . , r . 1i� I 1 _...„...., ____ , . YIEM $HOWN MODEL (! PFNDFNi SPRINRIfR ?011[x • 1 . Model C -3 Guards r ....orrillv—aN un,-.` ., :1; :It, ordieller lakihr, irt 'L AO T• �lr �j� SO! r�n ? 1 OWN MoD I (1Fli UPRIGHT NK SPPo iR SHOWN MODFL D IIPRIONT SPPoNKI iB MOWN MOOR MR UPRI(.Ni SKUNK! re i SH .2OdCl6 I Model C -5 Guards I 1 - - ...., f_rtftaa . \\4=rii i'..--,1 , , •-•-:.'N Th io. 41=to - !, 4 I _SHOWN MODEL Fl FR PENDENLSP.BIN_KER SHOWN MODEL FI PEN_DEHT SPRINKLER \ � SHOWN MODEL G PENDENT SPRINKLER '� • 2OBLE0 I 2. I I f Model D ='1 Guards - Model D.7'3 Guards i ._•=1-k . it2 . ill ...- --..._=---__ -41..._ ......cdp- = .. F .. fele_ ill_ SHOWN MODES G SPRINKLER; DOWN MODEL II SPRINKLER'. :72 — RERShl • 1!ffiXl SHOWN MOOFI G SPRINKLER SHOWN MODEL F1 SPRINKLER ' ::4.' . — ell i �l �� ModelD -5 Guards . SHOWN MODFl G SPRINKI FR, $MOWN MOM F1 SPRINKI FR :. _ lt� l�l - dill I �� _ - . ( ...--- i i I, ■ • \ill J SHOWN MODEL O 1/2' MPT SPRINKLER SHOWN MODEL FI 1/2' NPT SPRINKLER MoZtaitaisStsiti I SHOWN MOO I . SPR1N I ER SHOWN MODFL Ft CPRINKI FR -_17-7. -- - -- 'xi°" anru� TOBDtB Wall 1 IpJ Model-D-4 Guards SHOWN MODEL G 3/4' NPT SPRINKLER $MOWN NOSEI El 314' NPT' SPRINKLE IF 508000 .1 . ERR: {R;► I __ .ff i``'t -- --or,-!" Model -D -6 Guards [ r r A A ffl 4. ft SHOWN NOM DFR I /2.• NPT SPRINKLER SHOWN MODEL GFR 3/4' NPT SPRINKLER - Ii! �l - MUM gal i . 1111. Il_1I MOOFI G XIS'DI I /2• PIPE SPRINKLER 1IOOFL S XIOT31 314' NP7 SPRINKI FR . UPRK.H! INITRA?ON6 1RN.Nt INITIN'OMIF i •• . 3. I I Guards are approved to be used with sprinklers listed below. I Approvals with SIN Number Guard Model (3) Sprinkler Model Sprinkler Type Orifice Sizes MEAD), SSL , 1 Application cULus FM R3611, R3613, R3615, • 1 R3612, R3621, R3623, • R3625, R3622, R3111, R3113, R3115, R3117, R3121, R3123, R3125, R3127, R3635, R3131, 1 Pendent, Upright, 3/8 ", 7/16", 1/2" R3133, R3135, R3137, D -1 G, GFR, F1, F1FR HSW 17/32" R1711, R1713, R1715, R1712, R1721, R1723, R1725, R1722, R1735, R1011, R1013, R1015, 1 R1016, R1017, R1021, R1023, R1025, R1026, R1027, R1231, R1233, R1235, R1236, R1237 R3625, R3622, R3125, • 1 D -3 G, GFR, F1, F1FR Upright Intermediate 1 /2 ", 17/32" R3127, R1725, R1722, R1025, R1026, P1027 D -4 G, GFR, F1, F1FR Pendent Intermediate 1/2", 17/32 R3115, R3117 (Large Shield) Pendent Intermediate R3615, R3612, R1715, D -5 G, F1, F1FR 1 /2 ", 17/32 R1712, R1015, R1016, I (Small Shield) R1017 D -6 G XLO Upright Intermediate 0.64 R2921 R1011, R1015, R1016, I R1017, R1021, R1025, Pendent, Upright, R1026, R1027, R1235, HSW, Vertical R1285, R1712, R1715, C -1 G, F1, F1FR 3/8 ", Y", 17/32" Sidewall, Upright & R1721, P1725, R1735, Pendent R1785, R3612, R3615, R3622, R3625, R3635, R3685 C -2 F3, F3QR Pendent 1/z" R, R4214, R55 R4216 R5314, R5714 R3625, R3622, R3125, R3625, R1725, C -3 G, GFR, F1, F1FR Upright Intermediate 1 /2 ", 17/32" R3127, R1725, R1722, R1025, R1027 1 R1025, R1026, R1027 R1015, R1017, C -5 G, F1, F1FR Pendent Intermediate 1 /2 ", 17/32" R3615, R1715, R1712, R3612 I • ( MEA approval on D -1, D -3, D -4, D -5, C -2, and C -3 ( SSL approval on C -1, C -2, and C -3 ( Model GFR does not have FM Approval. 1 ( Sprinkler guards are listed and approved only for use with specific sprinklers. The use of any other • guards on these sprinklers may impede their operation or distribution and negate all approvals and warranties. • I 1 4. • I I. O:verall".Cage :Size: • Model 13 I . Before a sprinkler is installed into a fitting, assemble Models C -1. C -2. C -5 the guard on the sprinkler using same technique - 2' / ",(73hm) High X 2Y" (70mm) Diameter described above for the - Model - -C: Guards.. Then I install a 1" or 3/4" locking nut on to the NPT threads . Models C -3. D- 3:•D =6 until the nut is tight against.the - guard°. Each guard is I 2;' °(70mm) High X 4y "- (114mm) Diameter supplied with both size:- of locking -. nuts. The assembly of sprinkler and guard is .then wrenched I into place using an adjustable, wrench maximum- Models D -1: D -5 size 8" and a jaw opening of'1% ".(for D -1, D-3,.11-4 " 2% ". (67mm) High X.3 " (76mm) Diameter or D -5) or an adjustable wrench maximum size 10" and a.jaw opening of 15(8-'- (W13,6). Model_C -4 -, Wrench must be placed over_ the guard. Do not_ 2 %" High X 4y" Diameter use the wrench directly on the sprinkler wrench I boss. The sprinkler wrench boss requires -a Installation Instructions_ special wrench. • Model C Guards. With both cups unhooked, slightly spread open the Finish I guard. Insert steel plate into the installed sprinkler Standard Finish —Zinc with chromate dip. between the "threads and the wrench flats. The steel Other finishes, quoted on request. plate tabs should face_the sprinkler wrench flats and four contact points engage the sprinkler neck. I For Model C -2, the steel plate fits into the groove in Ordering Information each wrench flat and the guard is located by the notch in • Guard Type (D -1,D -2 etc.) both steel plates. • Finish (Standard or other) I Snap the farther locking clip into place, then close the near clip. The guard is now securely installed in place. If • Sprinkler Inlet Thread Size, locking clip requires too much force to snap closed or D -4 & D -5 Guards Only. I open, slightly flex the wires on both sides of the clip and • Optional: Consult Factory for assembly on either close or open the clip. sprinkler. Specify Sprinkler: – Type. – Temperature Rating. – Finish. • Wrench: Not supplied by .Reliable I I I . 1 I I I 5.- . 1 Reliable...For Complete Protection 1 Reliable offers a wide selection of sprinkler components. Following are some of the many I precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves I P g • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers Check valves . • Concealed automatic sprinklers . • Supertrol electrical system 1 • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches 1 • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers , • Inspectors test connections I • Spray nozzles • Sight drains • Alarm valves • • Ball drips and drum drips I • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices I • Accelerators for dry pipe valves • Air compressors • Mechanical gauges sprinkler alarms • Pressure au p 9 g • Electrical sprinkler alarm switches • Identification signs I • Water flow detectors • Fire department connection . I • 1 1 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory I Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ;,, Recycled Paper - The Reliable Automatic Sprinkler Co., Inc. H e''�b'e® (800) 431 -1588 Sales Offices i (600) 648 -347 Sales Fax Revision lines Indicate updated or new data. (914) 668470 Corporate Offices p www.rellablesprinkler.com Internet Address E.G. Printed in U.S.A. 8/04 P/N 9999970152 - I I . Cast Iron Threaded Fittings ("sr) AN ATION I L. INC. 1 90° Elbow Straight Size A B Weight (Ibs) Figure 351 • (NPS) (in) (in) black galv. 1 /4 1/2 13 /16 .16 .17 I 3 /a 9 /i6 15 /16 .25 .26' '/2 "/i6 1' /e, .40 .41 3 /4 13 /16 1 .60 .61• 1 15 /16 1 .92 .95 - . 1'/4 1' 1 1.44 1.46 . f e� 1'/2 15/16 115/ 1.95 2.00 II at A I 2 19/is 2'/4 3.13 3.21 2' /z 1 2 4.94 5.13 - 3 2 3% 7.21 7.40. I _ 1 4 2'.'/16 3 12.17 12.67 5 3 4'/2 21.46 6 3 51/2• 31.33 33.33 8 5 61/46 64.56 67.14 Cast Iron Threaded Fittings • Pressure - Temperature Ratings II, Pressure, (psig) Temp.( °F) Class 125 " Class 250 -20° to 150° 175 400 I 200° 165 370 250° 150 340 300° 140 310 I 350° 125 300 400° 250 I I I I I I www.anvilintl.com (12/10/01) -I I I Cast Iron Thread Fittings 7r, ANVIL Class 125,. (Standard) INTERNATIONAL, INC. 90° Reducing Size A B C D Weight 1 Elbow - Figure 352 (NPS) (in) (in) (in) (in) (Ibs) - black 1/2 1 /4 5 /5 1/4 11/46 1 ' /16 . .40 1/2 3 /5 5 /6 11 /16 11/46 11/4e .34 .5 1 1 3 /4 1 /2 11 /16 13 /16 1 3 /1e 11/4 1 1/2 " /1e 15 /16 1'/4 1% .67 1 3 /4 ' 15 /16 1% 1 .76 11/4 1/2 "/1e 1 1 1 1/2 1.07 I 1'/4 3 /4 17 /is 1' /e l'/1e 1 1.02 1 1 "As 1%e 1 1"A a 1.21 11/2 1/2 1/4 11/4 1 /e 1% 1.53 11/2 3 /4 '/6 l'/1s 11/2 1 s 1 .5 5 I 1 1/2 1 1 1' /4 1 /e 1"/1s 1.44 11/2 11/4 1 1 1 1% 1.74 2 '/2 1 1 1 1 2.22 2 3 /4 1 11/2 1 /e 2 2.20 2 I 1 1'/16 1 /16 1 2 2.Q8 2 1 1/4 1 1 /1e 1 /e 2'/16 2.33 -- Me ' 2 11/2 1 1 2 2 2.59 I 2 2 1 1' /e 2'/1s 2 4.01 _D 2'/2 1 1 1 1 2 2.93 21/2 11/4 1 1 2'/36 2 3.41 ._�_ ;__ _________ 2 1 1 1 2 2' /1e 3 I 3 11/4 1% 2 2 2 5.98 3 1 1% 2 2 2 5.65 3 2 1% 21/4 2 2 5.65 3 21/2 1' /e 2 2 3 6.44 II 3 3 2 2 /1e 3 /le 3 8.95 4 2 2 2 /As 31/4 3 11.89 4 21/2 2 2 3 3 11.27 I 4 3 2 2 3 3 10.63 4 31/2 2 %e 2 "/1s 3 3'1/16 11.89 5 4 2 3 4 4 16.47 0 5 21/2 2 31/2 4 4 19.88 5 3 2 3 4 4 19.00 6 3 2 /is 3 3 4 19.43 6 4 21 3 4 4 23.53 I 6 5 3 3 4% 5 26.66 8 6 4 5' /e 5 6 51.11 • Cast Iron Threaded Fittings Pressure - Temperature Ratings Pressure, (psig) I Temp.( °F) Class 125 Class 250 -20° to 150° 175 400 200° 165 370 I 250° 150 340 300° 140 310 350° 125 300 400° - 250 I I • www.anvilinacom (12/10/01) I I I Cast Iron Threaded s Fittin J. 9 . Class 125., (Standard) ANVIL t km" INTERNATIONAL. INC. H • Straight Tee Size A B Weight (Ibs) • • I Figure 358 (NPS) (in) (in) black galv. '/9 1 /2 13 /16. . Z 2 .2 3 3 /6 5 /6 1 .35 .36 • . i ro:'''IS 1/2 'Y76 1' /° .56 .58 3 /. " /,s 1 /,° .84 .85 • 1 ' 1' /2 1.25 1.31 • • 11/4 1 1 2.03 2.07 ' I r - B 11/2 1 5 /,6 1 2.70 2.72 - 2 1 %6 2 4.23 4.33 • -A-•-wA-- 21 1 2"A6 6.67 6.79 • "" " " "" } 3 2 3'/6 10.00 10.16 A 31/2 2 3'/,6 13.29 13.82 4 2"A6 3 16.33 16.99 • 5 3 4' /z 27.33 27.67 6 3 5'/6 40.85 41.40 8 5 6 ° /,6 79.00 81.25 • Cast Iron Threaded Fittings I j Pressure - Temperature Ratings Pressure, (psig) Temp.( °F) Class 125 . Class 250 -20° to 150° 175 400 200° 165 370 250° 150 340 300° 350° 140 310 125 300 400° - 250 I 1 I . I . 1 I www.anvilintl.com.(i2 /1O /O1)' I Cast Iron Threaded Fittings Z � L Class 125, (Standard) C INTERNATIONAL. INC. Reducing Tee Figure 359 D-- - E1 Reducing Tee: Figure 359 I rl Size (NPS) A B C D E F Wt. (Ibs) A s B s x t x u (in) (in) (in) (in) (in) (in) black galv. C ; F 1' /s 13 /i5 1' /e 11/4 1 /is 1 1 1.93 - YY 11/2 15 /15 11/4 15 /, a 1 1''/1 a 1 2.14 - t 1/4 1 15 /16 11/4 15 /18 1 15 /16 1 1/4 1 15 /, 6 2.18 - Reducing Tee: Figure 359 1/2 13 /16 3 /4 11/4 11/46 15 /,2 1'Y,6 1.75 - Size (NPS) A B C D E F Wt. (Ibs) 3 /4 7 /e 73 /+2 1 1 1 1 1.7 - I s x t x u (in) (in) (in) (in) (in) (in) black gals. 1 1 1 1 1/4e 1 1 /e 1 1 1.72 - 1/4 ''/16 "/16 13 /, 1' /e 1 Ye 1 0.57 - 1 /s 13 /16 1 Ye 1 1 1 1 /e 2.08 - 11/2 15 /15 11/4 "As 1 1 1' 2.29 - 1/2 1/ 2 3 /e 'Y, e ' 1 /, s 3 /4 1 1' /e 1' /e 0.5 7 - 2 1'/2 1 e 15 /16 2 Ye 2 2 2.91 - a 0.68 1 ' 3/4 13 /16 ' 3 /1 6 ' 1 /1 6 11/4 1 /4 13 /1 1/2 13 /16 11 /16 1 1 15 /16 1 "/16 1.67 1.73 1 1 1 13 /18 1 1 1 1 - 1 /4 3 /4 ' 3 /16 ' 5 /18 13 /18 ' 5 /1 8 1' /4 15 /1 6 0.79 - 1 1 /2 3 /4 7 /B 73 /1 B 1 1 /4 1 1 /2 1 7 /+6 1 3 /4 1.79 - 1 /2 "/16 11 /16 13 /16 ' 6 1'/2 . 11/4 0.64 - 1 1 1 1 15 /16 1 1 /4 1 5 /B 1 B /16 1' 3 /18 1.97 Z . 0 5 I 1/2 3 /4 13 /1 9 13 /16 ' 3 /18 ' 5 /18 11/4 ' 8 0.7 5 - 1' /B ' 3 /18 1'/B 11/4 1' 3 /16 1 1 2.28 - 11/2 15 /12 1 15 /1e 1 /ie 1 1 2.5 - 3 /4 1/4 B/i a B /+e 7 /e "/� s ' Yi a 13 /1 a 0.62 - 3 11 11 1 13 13 1 2 11/2 1 a 15 /16 2 2'/16 2 3 .07 - 3/4 ' /2 ' 1 /1 a /18 1 16 18 1 0. 7 5 - 1/2 13 /18 13 /16 1'/4 11/4 8 1 7 /1 B 1"A 8 1.84 - I /2 /�e 11 /i 6 ' /i ' 3 13 /� e /is s 11/4 1/4 0.76 - 3/4 7 /6 7 /e 1 11/2 11/2 1 3 /4 1.95 - 1 ' e ' 5 /1 B ' 6 1 7 /16 11/46 1 0.99 - 1 1 1 1 1/4 1 /e 1 /e 1' 3 /16 2.13 2.17 1 1 15 /16 15 /16 15 /1 B 11/2 11/4 11/2 1.08 - 1 , 13 13/16 1 13 13 7 1 /2 "/19 3 /4 ' 5 /16 1'/4 ' 3 /1 e 1 3 /e 0.9 - 1 /6 /16 1 /4 1 /, 8 1 /i e 1 /e 2.44 - 1/2 3 13 13 15 / 7 2 1 1 15 /16 2 2' /B 2 3.23 - ill /2 /1 /18 /1 B 8 1 3 /6 1 1 /4 1 /1 B 0.91 - 2'/2 1' 1' 3 /18 '5/le 21/46 2 2 4.15 ' - 1 ' S/1 B 15 /18 15 /16 1 1 1 1.08 - 1 '/2 "A 6 1 3 /6 1 2 1"A 2 V 2.95 1 /2 "/1 s "/, B 15 /18 11/4 13 /16 1 3 /B 0.89 - ' /2 - 3 3/4 13 13 15 3 1 5 7 2 1 11/4 s 1 a 2 1 2'/4 3.3 1 h /4 /ie /1 6 /e 1 /e e 1 s 1 - 1' /e '3 /,s 1 1 1 1 2YiB 2.5 - 1 15 /16 + B 15 /1 8 11/2 11/46 11/2 1 - 1/4 1 '/2 '3/46 "As 11/2 2 1 Z' /2 3.4 1/4 "/ie "As 1' /e 11/2 11/4 1 1.01 - 2 13/4s 11/4s 1 21/4 1 6 21/4 3.31 - 1 +1 11/12 15 /12 11/4 1 1 1.01 1.03 1 I /, '' /, e 1 1 3 /4 1 2 2.7 - 1 3 /4 ' e +3 /16 ' 1 3 / /8 1 33 / /9 11/4 B 1.11 - 1' /e 13 /1 8 1'/8 11/2 11/2 1 3 /4 2'/18 2.94 - 1 1'/e 1 15 /18 1"A e 1 "A6 1 e 1.49 - 1 11/2 ' 1 11/2 2 1 2 2.85 - 1' /z 1'h 11/4 1 1 1 1% 1.84 - 2 1 6 1 13/46 21/4 2 21/4 3.46 - 1 /2 13 /16 13 /is 1 1 a 15 /18 1 5 /B 1 - 2'/2 1 7 /s 1 1 2 /, a 2 B 2 2 4.8 8 - I 1/2 1 15 A8 15 /18 1'/2 1 1 1' 1.38 - y +y,s 1 1 1 1 /e 2 2.48 1 1' /e 11/2 11/2 1 13/46 1 1.64 - 3/4 13 /16 ' 3 /16 1' /8 11/4 B 15 /18 1 5 /2 1 . 2 7 - 3 /4 7 /B 7 /B 1 7 /1 s 13/4 s 1 1 /2 1' 5 /16 2. 5 - 1 " /,s 1 1 /+s 1 1 2 2.73 - 3/4 I 1 ' S/1 B 15 /18 1'/e 1 2 /18 1 7 /+6 1 11 /1 B 1.4 3 - 1' /s 1 1 /8 13 /16 1'/8 11/4 s 1 7 /B 1 3 /4 2 2.9 1 1' /e 1' /e 1' /e 1 1 /e 13/4 1.73 - 11/2 15 /16 11/4 11/2 2 1 /e 2 3.13 - '/2 "Aa "/I a 1 1 /e ' 11/4 1 a 1.27 1.3 2 2 1 a 1 a 1 e 21/4 21/1 a 21/4 3.71 - 3/4 13 /16 13 /16 11/2 11/46 1 1 1.36 - 2 1 7 /e 11/4 1 2 /18 2 2 2 4.54 I 1'/2 1 ' S /1 e ' S/1 a 1'/e 1 %6 1 1' 1 /16 1.53 1.56 1 1/z ' 6 ' 3 /1 a 11/4 a 1' /2 1 7 /1 6 1 2.34 2.38 1 1'/e 1'Ae 1'/e 11/4 1 ' 'A s 1 1.79 - 3/4 7 /2 7 /e 1 1 1 1/2 1 2.46 - 1'/2 11/4 11/4 13 /16 1 7 /5 1 1 2.07 - 1 +y1e 1 1 1 /e 1 2 2.66 - 2 1 1 7 /, 8 ' 2'/18 2 1 2.66 - 11/2 1 /e ' 13 /18 17/le 11/2 1 2 2.98 - I 7 /2 "/16 11 /16 1 'A '3/46 15 /1 e 1 2 /18 1 . 4 7 - 1 15 /16 15 /ie 1 2 1 t a 2' /s 3.24 - 3 /4 ' 3 /18 ' 1' /e 1 1 7 /1 a 1 1.57 - 2 13/46 11/2 13/4 e 2 1/4 2 21/4 3.7 - 1 Ye 1 15 /16 15 /18 1'/6 1 6 13/46 1"/I a 1.73 - 21/2 1 1 S /16 1°/is 2 23/46 2 B 5.46 - 1' /z 1'/4 1'/4 13 /,8 1 1 /e 1 73 /+6 2.29 - '/2 13 /ie 13 /+8 1 1'/2 1 1 2.74 2.81 2 1 B 17/le 13 /18 2'/18 2 1 /18 1 2.81 - 3 /4 7 /e 7 /e 1 7 /1 B 13/46 1 2 /18 1' 5 /16 2.8 6 1 " /i6 " /+6 1 7 /1 6 1 1 2 3.05 3.14 2 1' /s 13 /,e 13 /i6 1 1 /e 1 /e 2' /,e 3.38 - See additional sizes on following page. 1 '/2 75 / +a 15 / +6 1'/2 2 2 2 3.59 3.74 Note: See last page for pressure - temperature ratings. 21/2 1 1 1 2 /,s 2 2 5.17 5.38 4 3 3 2 3 " /AB 3 3 16.07 - I www.anvilintl.com (12/10/01) I I IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.04 I VICTAULIC" IS AN ISO 9001 CERTIFIED COMPANY Style 77 Standard Flexible Coupling I PRODUCT DESCRIPTION . Style 77 couplings are designed with cross - ribbed construction to provide a strong component for pressure piping systems. Sizes 3 /4 -12" (20 - 300 mm) are two -piece housings. Sizes 14 - 22" (350 - T. . '� -�� 550 mm) are cast in four identical segments, with larger sizes cast in six segments. This eases handling � „' ; �� �+ y and assures concentricity. 1 • All sizes are provided with plated bolts and nuts. Galvanized and stainless steel housings are also , 1 I "" '� available. I � Independent testing has shown the Style 77 coupling to be an effective stress relief and vibration attenuation device providing performance superior to braided steel and elastomeric arch -type connectors when used in close proximity to the source of vibration. Refer to 26.04 for vibration I information. Ai Independent testing has shown that Victaulic Style 77 and 75 flexible couplings and Style 07 Zero-Flex® rigid couplings provide exceptional functionality during and after earthquake conditions. Refer to 26.05 for further information. I ®<>- ® Exaggerated for clarify I DIMENSIONS ' , I eflect. Fr. Dimensions Pipe Size Max. Mex. Max. Mex. Work End Allow. CI. t Inches/millimeters Aprx. ^ Pipe B0WNut Wgt. rrrr max= Nominal Actual Pres. Load End t Per Pipe No. - Size Each 4 Diameter Out. Dia. PSI' Lbs.' Sep. Cpig. In/Ft. Inches Lbs. _ in/mm In./rim kPa N mm Deg. mmlm 72 mm X Y Z kg 3 /4 1.050 1.000 865 0 Ind - 0.06 0. 2.13 4.00 1.75 1.1 �� L�1 3 ° -24' 2 - 3 /8 X 2 "�_/ 20 26,7 6900 3850 0 - 1,6 60 54 102 44 0.5 1 1.315 1,000 1,360 0 - 0.06 2 , 43 , 0.57 2 3/s X 2 2.38 4.12 1.75 1.2 3 '4 - 12" Sizes 25 33,4 6900 6050 0 - 1,6 48 61 105 44 0,5 I 1 1.660 1,000 2,160 0 - 0.06 2, 10' 0.45 2 1/z X 21/2 2.65 5.00 1.88 2.0 32 42,2 6900 9610 0 1,6 38 67 127 48 0.9 1 1.900 1.000 2,835 0 - 0.06 1 ° 56' 0.40 2 '/z X 21/2 3.13 5.38 1.88 2.1 40 48,3 6900 12615 0.1,6 33 79 137 48 1,0 2 2.375 1,000 4,430 0 - 0.06 1° - 31' 0.32 2 1/2 X 21/z 3.63 5.88 1.88 2.6 I 50 60.3 6900 19715 0.1.6 26 92 149 48 1,2 2 2.875 1,000 6,490 0 - 0.06 1° - 15' 0.26 2 1/ X 23/4 4.25 6.50 1.88 3.1 65 73.0 6900 28880 0 - 1.6 22 108 165 48 1,4 76,1 mm 3.000 1,000 7,070 0 - 0.06 1 ° - 12' 0.26 2 1/2 X 23/4 4.38 6.63 1.88 3.2 76.1 6900 31460 0-1.6 22 111 168 48 1.5 I 3 3.500 1,000 9,620 0 - 0.06 0.22 5.00 7.13 1.88 3.7 80 88,9 6900 46810 0 - 1,6 1° - 2' 18 2 - 112 X 23/4 127 181 48 1,7 3 4.000 1.000 12,565 0 - 0.06 0° - 54' 0.19 2 - 5 !e X 3114 5.63 8.25 1.88 5.6 90 101.6 6900 55915 0 - 1,6 16 143 210 48 2.5 I 4 4.500 1,000 15,900 0 - 0.13 0.34 6.13 8.88 2.13 6.7 1 ° - 36' 2 i:/88 X 3 100 114.3 6900 70755 0 - 3.2 28 156 226 54 3.0 108,0 mm 4.250 1.000 14.180 0 - 0.13 1° - 41' 0.35 2 X 82.5 6.00 8.63 2.13 11.0 • 108.0 6900 63100 0 - 3,2 29 152 219 54 5,0 5 5.563 1,000 24,300 0 - 0.13 1 ° - 18' 0.27 2 3/4 X 41/4 7.75 10.65 2.13 10.6 125 141,3 6900 108135 0 - 3,2 23 197 270 54 4,8 133,0 mm 5.250 1.000 21,635 0 - 0.13 1° - 21' 0'28 2 - 20 X 108 7.63 10.38 2.13 10.0 133,0 6900 96275 0 - 3,2 24 194 264 54 4,5 139,7 mm 5.500 1.000 23,745 0 - 0.13 1 ° - 18' 0.28 2 - 20 X 108 8.63 10.65 2.13 10.0 139,7 6900 105665 0.3,2 24 219 270 54 4,5 6 6.625 1,000 34,470 0 - 0.13 0.23 8.63 11.88 2.13 12.0 1 168.3 6900 153390 0 3,2 18 2 X 4 219 302 54 5,4 159.0 mm 6.250 1,000 30,665 0 1 ° - 5' 0.13 1° 9 , 0.24 2 - 20 X 108 8.63 11.50 2.13 13.2 159.0 6900 136460 0 - 3.2 20 219 292 54 6,0 6.500 1,000 33.185 0 - 0.13 0.23 8.88 11.63 2.13 13.2 165,1 mm 165,1 6900 • 147660 0 - 3,2 1° - 6' 19 2 - 3/4 X 41/4 226 295 54 6.0 Table continued on p age 2. - t@ Refer to notes on page 2. 0 REGISTERED TRADEMARK OF VICTAUUC - O COPYRIGHT 2005 VICTAULIC - PRINTED IN U.S.A. - SKU 4WCAS-6AYRPa 1469 REV G United.States • Phone: 1-800-PICK-VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com Canada • Phone: 905=884 -7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Europe • Phone: 32-9-381-1500 • Fax: 32 -9- 380 -4438 • e -mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@victaulic.be ' ��� �', � ® Central and South America • Phone: 610. 559.3300 • Fax: 610 - 559 -3608 • e-mail: vital @viclaulic.com I Australasia • Phone: 86-21-58855151 • Fax: 86-21-58851298 • e -mail: vicap @viclaulic.com I 06.04 DIMENSIONS I r Max. Max. Allow. Deflect. Fr. Dimensions Aprx. Pipe Size Work End Pipe CL t CO owNut Inches/millimeters Wgt 1 �� Nominal Actual Pres. Load End t Per Pipe No.- Size Each [1 15. 1101, Diameter Out. Dle. PSI' Lbs' Sep. Cpig. InJFt. Inches Lbs. InJmm InJmm kPa N InJmm Deg. mm/m mm X Y Z kg - 50' .18 2 - 7/ X 11.00 14.75 2.50 20.8 ° 5 200 219,1 5500 207995 0 - 3,2 14 279 375 63 9.4 ° r 10 § 10 800 73 0 - 0 0° - 40' 0.14 2 - 1 X 6 13.63 17.13 2.63 31.1 •`` 250 273.0 5500 326100 0 - 3,2 12 346 435 67 14,1 mr- 12 § 12.750 800 102,000 0 - 0.13 0° - 34' 0.12 2 - 1 X 6t / 15.63 19.25 2.63 27.8 300 323,9 5500 453900 0 - 3.2 9 397 489 67 12,6 I 14 - 22" Sizes 14 14.000 300 46,180 0 - 0.13 0.11 16.63 19.88 2.88 35.6 350 355,6 2065 205500 0 - 3.2 0 - 31' 9 4 • 1 X 3' /2 422 505 73 16,1 15 15.000 300 53,000 0 - 0.13 0° 29 , 0.10 4 - 1 X 5' /z 17.88 21.63 3.00 48.8 375 381.0 2065 235850 0 - 3.2 9 454 549 76 22,1 1 1: 16 16.000 300 60.320 0 - 0.13 0 - 27' 0.10 4 - 1 X 31/2 19.00 22.13 3.00 51.1 I ���. 400 406,4 2065 268425 0 - 3.2 9 482 562 76 23,2 1 F . 18 450 18.000 300 76,340 0 - 0.13 0 21.38 24.50 3.13 64.4 457,2 2065 339710 0 3,2 0° - 24' 7 4 - 1 X 31/2 543 622 80 29,2 0 ° -22 4 -1 / X 4 I 20 20.000 300 94,000 0 - 0.13 0.0 23.63 27.25 3.13 91.2 500 508,0 - 2065 418300 0 - 3.2 7 600 692 80 41,4 I 22 22.000 300 114.000 0 - 0.13 0.07 25.75 29.50 3.13 92.0 ,'e 1 550 559.0 2065 507300 0 - 3.2 0 - 19' 6 4 - 1 /e X 4 654 749 80 41.7 � illi El 24 24.000 250 113,000 0 - 0.13 0.07 27.75 31.25 3.13 94.0 24° Sizes 600 609.6 1725 502850 0.3.2 0° - 18' 6 6 - 1 X 4 704 794 80 42,6 § Couplings 8, 10. 12' (200. 250, 300 mm) sizes available to JIS standards. Refer to Section 06.17 for details. •1@ Refer to notes below. NOTES ' Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with I Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 1 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3 /4 - 3 (20 - 90 mm); 25% for 4' (100 mm) and larger. I @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. MATERIAL SPECIFICATIONS • I Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. I Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others Coupling Gasket: (specify choice ")t I • Grade "E" EPDM EPDM (Green color code). Temperature range -30 °F to +230 °F ( -34 °C to +110 °C). Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F ( +30 °C) and I 1 hot +180 °F ( +82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrite Nitrile (Orange color code). Temperature range -20 °F to +180 °F ( -29 °C to +82 °C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 °F ( +66 °C) or for hot dry air over +140 °F ( +60 °C). 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which I are not recommended. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. tSupplemental lubricant is recommended for services installed at or continuously operating below 0 °F I (- 18 °C). • Optional: Type 316 stainless steel, Grade B -8M, Class 2. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 Style 77 Standard Flexible Coupling I IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.O8 _ S tyle1.7:50 Reducing Coupling VICTAULIC" IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed to replace two couplings and a reducing fitting, the Style 750 features a special reducing gasket for pressure responsive I - sealing. A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. I „ . ® 0 I .. ,,,,,,, 1. � 1 i ii • I Exaggerated for clarity DIMENSIONS. I . Y r I Z I Max. Max. Allow. Deflect. Fr. Dimensions Aprx. C1 f inches/millimeters Work End End Wgt. � -� : Nominal Size Pres. Load End t Per Plpe Bol Siz e Each I ' /� `� =' "' Inches PSI* LbsIn./Ft. . No. - Size Lbs. // mm kPa N mm Deg. mm/m Inches X Y Z kg 7 2 X 1 350 1000 0 S ep. In. - 1,8 Cplg. In./Ft. 3.36 134 1 1.88 2.7 50 X 25 2410 4450 0 - 1,8 0 ° - 57' 17 2 " 3 /B X 2 85 134 48 1,2 X 1 V2 350 1000 0 - 0.07 0° 57 . 0.20 2 - 3 /6 X 2 3.38 5.28 1.88 2.0 X 40 2410 4450 0 - 1.8 17 85 134 48 1.0 2 X 2 500 2215 0 - 0.07 0 ° - 47' 0.16 2 , 3 / e X 2 4.00 5.93 1.88 3.1 Y Z 65 X 50 3450 9850 0 - 1.8 14 102 151 48 1,4 ^ I 76,1 mm X 2 350 1550 0 - 1.8 0 °- 47 . 0.16 2 1 / 2 X 2'/ 111 168 1.88 4.6 X 50 2410 6900 0 - 1,8 14 111 168 48 2.1 3 X 2 350 1550 0 - 0.07 0.13 4.75 7,13 1.88 4.9 ur rir 7 /( 11 11 = 11 0 °- 39' 2 - 1 /2 X 2 I p,p 80 X 50 2410 6900 0 -1,8 11 121 181 48 2,2 �� �� �� . 4.75 7.13 1.88 4.3 13 �� I X 65 3450 14460 0 - 1,8 0 °- 39' 11 2 - IZ X 2 121 181 48 2.0 350 2275 0 - 0.07 0.13 4.75 7.13 1.88 4.2 88,9 mm X 76,1 mm 0 39" 2 - '/2 X 2 2410 10125 0 - 1,8 11 121 181 48 1,9 4 X 2 350 1550 0 - 0.13 1°- 19" 0.28 2 - St X 31/4 6.25 8.90 2.25 8.1 100 X 50 2410 6900 0-3,2 25 159 226 57 3,7 • X 2' /2 350 2275 0 - 0.13 1 °- 19' 0.28 2 - 5/e X 3'l4 6.25 8.90 2.25 8.6 I X 80 500 2 4810 00 0 0 -6 1 19' 0.28 2 - 5 /4 X 31/4 6.00 8.9 2 6 ,0 ■ 114,3 mm X 76 mm 2410 10125 0 0 0 3 2 3 1 °- 19 0 2 - S X 3V4 6.25 8.90 2.25 6.9 i 5 X 4 350 5565 0 - 0.13 0.22 7.18 10.70 2.13 11.2 125 X 100 2410 24765 0 1° 3 19 2 - 3 / 4 X 41/4 182 272 54 5,1 350 5565 1 X 100 2410 24765 0 0 0 3 2 0 ° - 52' 0.18 2 - 3 / 4 X 4'/ 8.63 13 2.25 16s O 8 X 125 2 - O 0.13 0.18 2 - 3 /4 X 41/4 8 t t 302 57 5.9 11.90 2.25 12.9 D 165,1 mm X 210 78 100 2410 10 24765 65 0 0 -0 3,2 " 3 0 °- 52' 55' 0 16 9 2 - 3 / 4 X 4 8 6 11.90 302 57 0 2.25 1 6.9 8 X 6 350 12000 0 - 0.13 0 °- 38" 0.13 2 - X 5 10.81 14.88 2.50 22.4 200 X 150 2410 53400 0 - 3,2 11 275 378 64 10,2 0 Refer to notes on page 3. Style 750 Reducing couplings should not be used with end caps (#60) in systems where a vacuum may be developed. Contact Victaulic for details. 0 REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2005 VICTAUUC - PRINTED IN U.S.A. - SKU OWCAS- 68AGXP 1536 REV G D Victaulic Company of America • Phone: 1-800-PICK-VIC (1 -800- 742.5842) • Fax: 610 - 250 -8817 • e -mail: pickvic@victaulic.com Victaulic Company of Canada • Phone: 905 -884 -7444 • Fax: 905.884 -9774 • e -mail: viccanada @victaulic.com Victaulic Europe,• Phone:32 -9- 381 -1500 • Fax: 32 -9 -380 -4438 • e -mail: viceuro @victaulic.be Victaulic America Latina • Phone: 610 -559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com cta u 1 i c I Victaulic Asia Pacific • Phone: 86 -21- 58855151 • Fax: 86- 21- 58851298 • e -mail: vicap @victaulic.com I 06.08 FLOW DATA I Head Loss Flow Reducing Flow Expanding The head loss across Style 750 Equiv. Pipe Equiv. Pipe Reducing coupling is very • Nominal Size Length Nominal Size Length small and is essentially the Inches Sm. Dia. Inches- Sm. Dia. Y mm FeeUm mm- Feet/m same as for standard short 2 X 1 5.9 1 X 2 2.7 I body reducing pipe fittings. 50 X 25 1,8 25 X 50 0.8 Equivalent lengths of standard - .x • 1 1 i: 2.0 1 1 X 2 1.9 weight steel pipe are shown in X 40 0,6 40 X 50 0.6 the tables. All data is based on 2'/a . x 2 1.9 2 x 2 1/2 1.0 water flowing at ambient 65 x so o,s so x ss o.s I temperature. 76,1 mm X 5 0 0 X 76:1 mm 0. 3 X 2 5.5 X 3 3.5 80 .. X '50 1,7 X 80 1,1 X 2' 3.8 X 4 3.0 I X 65 1,2 X 100 0,9 88.9 mm X 76.1 mm 3.8 2'k X 3 2.5 1,2 65 X , 80 0,8 4 X 2. 6.0 X 4 3.0 100 X 50 1,8 X 100 0.9 I X 65 1.8 76.1 mm X 88 mm 0,8 X 3 6.0 X 114,3 mm 3.0 X 80 1.6 2.5 I 114,3 mm X 76,1 mm 6.0 3 X 4 2.5 1,8 80 X 100 0,8 5 X 4 3.0 4 X 5 3.3 125 X 100 0,9 100 X 125 1,0 6 X 4 6.0 X 6 4.6 I 150 X 100 1,8 X 150 1,4 4 . X 5 4.5 X 4.6 X 125 1,4 X 165,1 mm 1,4 165,1 mm X 4 6.0 5 X 6 2.3 x 100 1.8 125 X 150 0,7 I 8 X 6 7.3 6 X 8 6.0 200 X 150 2.2 150 X 200 1,8 MATERIAL SPECIFICATIONS I Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available- upon special request. Housing Coating: Orange enamel' • Optional: Hot dipped galvanized and others Gasket: (Specify choice*): • Grade "E" EPDM I EPDM (Green color code). Temperature range -30 °F to +230 °F ( -34 °C to +110 °C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F ( +30 °C) , and hot +180 °F ( +82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. I • Grade "T" nitrile Nitrile (Orange color code). Temperature range -20 °F to +180 °F ( -29 °C to +82 °C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 °F ( +66 °C) or for hot dry air over +140 °F • I ( +60 °C). `Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional: Assembly Washer: Galvanized, carbon steel - Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. I I 2 ' • Style 750 Reducing Coupling I • IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 I VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Style 005 FireLock Rigid Coupling VIC m with Vic -Plus® Gasket System Gasket System I FAtEHIED PRODUCT DESCRIPTION I FireLock Style 005 rigid coupling has a unique, patented angle -pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. it // The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support I - and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle -pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installation on pipe grooved to Victaulic specifications. Style 005 FireLock couplings with the Vic- PIusTh Gasket System are designed and recommended for use ONLY on fire protection systems. Patented Vic -Plus Gasket System: Victaulic' now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic- PlusTM System (patented) is dry, clean, and non - toxic. It reduces assembly time substantially and I '1��I I eliminates the mess and chance of over - lubrication. Please refer to the latest copy of the Victaulic Field ;') Installation Handbook (1 -100) for supplemental lubrication requirements. 1��I II Ion VdS ® ® II C C V �tS § LPC and VdS Approved, E xaggerated for clarity Request Victaulic I ` i see notes on page 2. publication 10.01 for details. I DIMENSIONS � c:D • < z ► Dimensions ' Pipe Size inches/mm Actual Allow. Nominal Outside Work. End Pipe End @ Bolt /Nut Aprx. Diameter Diameter Press. §' Load' Sep. t No.- Size Wgt. Ea. Inches/mm Inches/mm Max. PSUkPa Max. LbsJN Inform Inches/mm X Y Z Lbs.kg t 1,660 350 755 0.05 3 2.75 4.50 1.88 1.2 Rated for wet and dry sprinkler 32 42,4 2413 3370 1,2 2 /8 X 2 /^ 70 114 148 0,5 systems at 350 psi (2413 kPa) 1 1.900 350 990 0.05 2 3/B X 2 3.00 4.75 1.88 1.2 40 48,3 2413 4415 1,2 76 121 148 0,5 for 1 4" (32 100 mm) sizes 2 2.375 350 1550 0.07 3.50 5.25 1.88 1,6 I and 300 psi (2068 kPa) for 50 60,3 2413 6900 1,7 2 - /e X 21/2 89 133 148 0.7 4 8" (108 200 mm) sizes; 2 2.875 350 2270 0.07 , 4.00 5.75 1.88 1.9 Schedule 10 roll grooved or 65 73,0 2413 10110 1,7 2 /a X 21/2 102 146 148 0.9 Schedule 40 cut or roll 3.000 350 2475 0.07 4.13 5.75 1.88 1 9 grooved steel pipe. Style 005 76,1 m m 76,1 2413 11010 1,7 2 3/ g X 21/2 105 146 148 0,9 is rigid and does not 3 3.500 350 3365 0.07 3/ 4.63 6.13 1.88 2,1 accommodate expansion, 80 88.9 2413 14985 1,7 2 - / g X 2 /2 118 156 148 1.0 contraction or angular 4 4.500 350 5565 0.16 , 5.75 7.25 2.13 3.1 deflection. 100 714,3 2413 24770 4,1 2 ' /e X z / 2 146 184 54 1.4 08 2068 18940 1 2 - 3 /e X 21/2 5.63 7.25 184 2.13 I 108.0 mm 1,4 5 5.563 300 7290 0.16 3 6.88 9.00 2.13 4.5 125 141,3 2068 32445 4.1 2 - Iz X 23/4 175 229 54 2.0 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133,0 mm 2 - 1 /2 X 2 ° 133,0 2068 28900 4,1 168 229 54 2,0 5.500 300 7125 0.16 6.88 9.00 2,13 4.8 139,7 mm 139,7 2068 31715 4,1 2 ' 1/2 X 23/4 175 229 54 2,2 6 6.625 300 10340 0.16 3 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4,1 2 - /z X 2 / ° 203 254 54 2,3 I 159,0 mm 6.250 300 9200 0.16 2 Sle X 41l^ 7.63 10.00 2.13 5.5 159,0 2068 40955 4.1 194 254 54 2.5 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165,1 mm 165,1 2068 44295 4,1 2 - 1 /z X 23l 207 254 54 2,5 8 8.625 300 17525 0.19 s 10.50 13.13 2.63 11,3 200 219,1 2068 78000 4.8 2 - / 8 X 4 / ^ 2 67 334 67 5.1 § t Refer to notes on page 2. a REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S.A. - SKU #WCAS- 67MHPN 1538 REV H Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e -mail: pickvic@victaulic.com Victaulic Company of Canada • Phone: 905 -884 -7444 • Fax: 905-884-9774 • e -mail: viccanada@victaulic.com Victaulic Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9- 380 -4438 • e -mail: viceuro @victaulic.be Victaulic America Latina • Phone: 610- 559 -3300 • Fax: 610-559-3608 • e -mail: vical@victaulic.com jctaulice I Victaulic Asia Pacific • Phone: 86 -21- 58855151 • Fax: 86-21-58851298 • e -mail: vicap@victaulic.com - - -- 10.02 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized Gasket: • Grade "E" EPDM - Type A Vic -Plus Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure us- ing the Grade "E" Type A Vic -Plus Gasket System, requiring no field lubrication for most installation condi- tions. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal Gasket. Contact Victaulic for details. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. 4 Standard gasket and FlushSeal gasket approved for dry pipe systems to -40 °F (- 40 °C). Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0 °F ( -18 °C) and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and /or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. LISTINGS /APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressure - PSI Rated Working Pressure - PSI Rated Working Pressure - PSI Pipe Size Plpe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches UL ULC FM Sch. Inches UL ULC FM 5 1 - 3 175 175 175 EL 1 - 2 300 N/A N/A MT 1 - 2 300 N/A N/A 1 - 4 350 350 350 ET 1 - 2 300 N/A N/A STF 1 - 4 N/A N/A 300 10, 40 Steady 5 - 8 300 300 300 EZ 4 - 6 300# N/A 300 Thd. 1 - 2 N/A N/A 300 BLT 1 - 2 300 300 N/A FF 1 - 4 N/A N/A 300 TF 3 - 8 N/A N/A 300 DF 1 - 4 300 300 300 GAL -7 1 - 2 300 N/A N/A WLS 1 - 2 300 300 N/A DT 1 2 300 300 N/A MLT 1 - 2 300 N/A N/A XL 1 - 3 300 300 300 EF 1 4 175@ N/A 175 MF 1 - 4 300 N/A 300" • FM approved for service in 1 - 4° pipe. # UL Listed for service up to 4° pipe only. @UL Listed for service up to 3 only. PIPE SCHEDULE NOTES: 111 5 refers to Listed /Approved Schedule 5 steel sprinkler pipe 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe BLT refers to Listed steel sprinkler pipe manufactured by Allied Tube & Conduit DF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by Allied Tube & Conduit DT refers to Listed Dyne Thread steel sprinkler pipe manufactured by Allied Tube & Conduit EF refers to Listed /Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose Tube Co. EL refers to Listed Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. ET refers to Listed Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed EZ •Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. FF refers to Listed Fire -Flo steel sprinkler pipe manufactured by Youngstown Tube Co. GAL -7 refers to Listed steel sprinkler pipe manufactured by IDOD Systems, LLC MLT refers to Listed steel sprinkler pipe manufactured by Wheatland Tube Company MF refers to Listed Mega -Flow steel sprinkler pipe manfactured by Wheatland Tube Company MT refers to Listed Mega - Thread steel sprinkler pipe manufactured by Wheatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex -Flow steel sprinkler pipe manufactured by Tex -Tube Company WLS refers to Listed /Approved steel sprinkler pipe manufactured by Wheatland Tube Company XL refers to Listed XL or XL II steel sprinkler pipe manufactured by Allied Tube & Conduit Corp. NOTES I • • Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 times the figures shown. i For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion /contraction. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 psi). WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 Style 005 FireLock Rigid Coupling IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1003 I VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY FireLock Fittings I PRODUCT DESCRIPTION Fire Lock products comprise a unique system specifically designed for fire protection services. FireLock I full -flow elbows and tees are a CAD - developed, hydrodynamic design that has a shorter center -to -end ear* dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain ^ similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of I other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. I 3 `' ,,%, Patented I %.,... ,, , ® 0 Az. liiiii I I I DIMENSIONS F No. 001 No. 003 No. 002 No. 006 I 1 Fitting Size 90• Elbow 45• Elbow Straight Tee Cap I - p Actual Aprx. Aprx. Aprx. Thickness AAprx. Weight 1 . - p _ Nominal Outside C to E Weight C to E Weight C to E Weight e: Diameter Diameter Inches Each Inches Each Inches Each Inches Each Inches/rum Inches/1nm mm Lbslkg mm Lbslkg mm Lbs.kg mm Lbsikg 1 1.660 - - - - - - 0.82 0.3 I No.001 No. 003 32 42.4 21 0.1 1 1.900 2.75 1.2 1.75 0.9 2.75 2.0 0.82 0.4 _ e I 8 _I 40 48.3 70 0.5 45 4.1 70 0.9 21 0.2 _ 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 I 0 �7 i' 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 - �`. 2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 �I _i 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 No. 002 No. 006 76.1 mm 3.000 3.00 3.30 2.25 2.4 76.1 76 1.5 57 1.1 - - - - ' 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 12 0.5 80 88.9 86 1.8 64 1.4 86 2.4 22 - 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - 106 mm 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 I 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159 mm 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - - 158.8 140 5.7 89 4.2 140 8.0 - - I 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 53 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 I 0 REGISTERED TRADEMARK OF VICTAULIC - O COPYRIGHT 2006 VICTAULIC - PRINTED IN U.S.A. - SKU HWCAS-67PJUX 1539 REV F I United States • Phone: 1-800-PICK-VIC (1.800- 742 -5842) • Fax: 610 - 250 -8817 • e -mail: pickvic @victaulic.com Canada • Phone: 905 -884 -7444 • Fax: 905-884-9774 • e-mail: viccanada @viclaulic.com Europe • Phone: 32-9-381-1500 • Fax: 32 -9- 380 -4438 • e -mail: viceuro @victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro @victaulic.be ' ��� �'' � a Central and South America • Phone: 610 -559 -3300 • Fax: 610 - 559 -3608 • e -mail: vical @victaulic.com I Australasia • Phone: 86 -21. 54253300 • Fax: 86 -21- 54253671 • e -mail: vicap @victaulic.com I 10.03 FLOW DATA Frictional Resistance I Fitting Size Equivalent Feet/meters of Straight Pipe Actual Straight Tee Nominal Outside No. 002 Diameter Diameter 90° Elbow 45° Elbow I inches/mm Inches/mm No. 001 No. 003 Branch Run 1 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 , 1.1 0.5 1 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1. 0.5 2.6 1.1 2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 1.4 2.3 11.0 4.5 I 76.1 1.4 4 0.7 3.4 .4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 I 4 4.500 6.8 3.4 ' 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 - 2.6 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 .13.0 33.0 13.0 200 219.1 9.1 4.0 .0 1 1,5 .5 10.1 4.0 I The flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS I Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized I • 1 1 I I .1 I 1 This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. ' Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 FireLock Fittings I I IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1004 I VICTAULIC ° IS AN ISO 9001 CERTIFIED COMPANY Style 744 FireLock Flange Adapter . VIC /(r/S I with Vic-Plus TM Gasket System Gasket System PRODUCT DESCRIPTION I Style 744 FireLock Flange adapter is designed for directly incorporating flanged components with ANSI CL. 125 or CL. 150 bolt hole patterns into a grooved pipe system. Sizes 2 - 8° (50 - 200 mm) are hinged for easy handling with integral end tabs which facilitate assembly. • "..'`„ • The design incorporates small teeth inside the key shoulder I.D. to prevent rotation. I L Because of the outside flange dimension, FireLock Flange adapters should not be used on FireLock fittings. When wafer or lug -type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. FireLock Flange adapters should not be used as anchor points for tie -rods across nonrestrained joints. I 2 - 8" Sizes Mating rubber faced flanges, valves, etc., require the use of a FireLock Flange washer. FireLock Flange adapters with Vic -Plus gaskets do not require lubrication. The gasket must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange'. Style 744 FireLock Flange Adapters with the Vic-Plus TM Gasket System are designed and I (4 Style for use ONLY on fire protection systems. Vic -Plus Gasket System: Victaulic now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic - tila --"S PlusTM' System (patented) is dry, clean, and non - toxic. It reduces assembly time substantially and eliminates the mess and chance of over - lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1 -100) for supplemental lubrication requirements. I j (Exaggerated for clarity) See victaullc , publication 10.01 for details. I DIMENSIONS Style 744 Sealing I Sizes 2 - 8" (50 - 200 mm) Surface Dimensions ANSI Class 125 and 150 Flange Pipe Size Max. Max. Inches/rim Incheslmillimeters APrs Actual Work End Wgt. Z Nominal Outside Press.' Load' No. Bolt Each Diameter Diameter PSI Lbs. Bolts i Size t "A" "B" Lbs. � •, Inm Minim kPa N Req'd. Inches Max. Min. W X Y Z kg Q� 2 2.375 175 775 2.38 3.41 6.75 6.00 4.75 0.75 2.7 it r / �i� �, 50 2.375 60.3 1200 3450 4 5 / e X 23/4 60 87 172 152 121 19 1,2 � � Y W 2' /2 2.875 175 1135 4 S te X 3 2.88 3.91 7.88 7.00 5.50 0.88 4.2 ,��//'7 I 65 73,0 1200 5050 73 99 200 178 140 22 1,9 3 3.500 I 88,9 175 1685 s 3.50 4.53 8.44 7.50 6.00 0.94 4.8 O O 80 1200 7500 4 /e X 3 89 115 214 191 152 24 2,2 O O 4 4.500 175 2780 s 4.50 5.53 9.94 9.00 7.50 0.94 7.1 100 114,3 1200 11045 8 / e X 3 114 141 252 229 191 24 3.2 Note: Gray area of mating face must 5 5.563 175 4250 5.56 6.71 11.00 10.00 8.50 1.00 8.3 I be free from gouges, undulations or 125 141,3 1200 18920 8 3 /4 X 3' /z 141 t 11 279 254 216 25 3,8 deformities of any type for effective sealing. 6# 6.625 175 6030 a 6.63 7.78 12.00 11.00 9.50 1.00 9.3 150 166,3 1200 26840 8 l4 X 3 Iz 168 198 305 279 241 25 4,2 8# 8.625 175 10219 8.63 9.94 14.63 13.50 11.75 1.13 13.9 200 219,1 1200 45475 8 /4 X 3 / z 219 252 372 343 298 29 6.3 I 'Refer to notes below. 1Total bolts required to be supplied by installer. Bolt sizes For conventional flange -to- flange connection. Larger bolts are required when Vic - Flange adapter is utilized with wafer -type valves. # Not available with Vic -Plus gasket system. Lubrication is required. I NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance.with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'/z times the figures shown. Style 744 FireLock Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement I at the joint. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. e REGISTERED TRADEMARK OF VICTAULIC - o COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S.A. 1477 REV D I Viclaulic Company of America • Phone: 1- 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 -250 -8817 • e- mail:pickvic @viclaulic.com Viclaulic Company of Canada • Phone: 905 - 884 -7444 • Fax: 905 - 884 -9774 • e -mail: viccanada @viclaulic.com Viclaulic Europe • Phone:32.9- 381.1500 • Fax: 32-9-380-4438 • e -mail: viceuro @viclaulic.be Viclaulic America Latina • Phone: 610 -559 -3300 • Fax: 610-559-3608 • e -mail: vital @victaulic.com jctaulliC3- I Viclaulic Asia Pacific • Phone: 65- 6235 -3035 • Fax: 65-6235-0535 • e -mail: vicap @viclaulic.com 1 10.04 VIC- FLANGE ADAPTER NOTES 111 • The Style 744 (2 - 8750 - 200 mm) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. 2 FireLock Flange adapter should not be used on FireLock fittings. When wafer or lug -type valves are used adjoining a Victaulic fitting, check disc-dimensions to assure proper clearance. 3 FireLock Flange adapters should not be used as anchor points for tie -rods across nonrestrained joints. Mating rubber faced flanges, valves, etc. require the use of a FireLock Flange washer. 4 Area A -B noted in the above drawing must be free from gouges, undulations or deformities of any type for effective sealing. 6 FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. 6 Flange Washers: FireLock Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic - Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal Flange Washer be inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing surface. • Typical applications where a Flange Washer should be used are: 111 A When mating to a serrated flange: a standard flat flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the FireLock Flange adapter and the flange gasket. B When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the FireLock Flange adapter. c When mating a rubber faced flange: the Flange Washer is placed between the FireLock Flange adapters and the rubber faced flange. D When mating AWWA cast flanges to IPS flanges: the Flange Washer is placed between two FireLock Flanges. The hinge points must be oriented approximately 90° to each other. If one flange is not a FireLock Flange adapter (e.g. flanged valve), then a standard flat flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock Flange adapter. E When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 1. F When mating to a Series 705 -W Butterfly valve, Style 744 may only be used on one side of the connection. When ordering Flange Washers, always specify product style (Style 744) and size to assure proper Flange Washer is supplied. MATERIAL SPECIFICATIONS Flange Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Coating: Black enamel • Optional: Hot dipped galvanized • Bolts /Nuts: Supplied by installer Gasket: • Grade "E" EPDM - Type A Vic -Plus Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Ap- proved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated work- ing pressure using the Grade "E" Type A Vic -Plus Gasket System, requiring no field lubrication for most installation conditions. 0 Standard gasket approved for dry pipe systems to -40 ° F (- 40 ° C). Based on "typical" pipe surface conditions, supplemental lubricant • is recommended for services installed below 0 ° F ( -18 °C) and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and /or cracks at the weld seams. 1 This product shall be manufactured by Victaulic Company_ All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 Style 744 FireLock Flange Adapter 1 IPS CARBON STEEL PIPE — FIRE PROTECTION FITTINGS 10.05 1 I VICTAULIC° IS AN ISO 9001 CERTIFIED COMPANY No. 10 -DR Drain Elbow I PRODUCT DESCRIPTION No. 10 -DR drain elbows are specifically designed for use on fire protection standpipes. The drain is I drilled and tapped for a 1" (25 mm) NPT outlet. 1111 , Constructed of durable ductile iron all sizes conform to the ratings of Style 77 couplings. No.10 -DR elbows are supplied with grooves or shoulders. These fittings are not intended for use with Victaulic Plain End couplings. I When connecting wafer or lug -type butterfly valves directly to Victaulic drain elbows with Style 741 or 743 Vic- Flange adapters or Style 744 FireLock Flange adapters, check disc clearance dimensions with the I.D. dimension of the fitting. I I See Victaulic publication 10.01 for details. I . I DIMENSIONS j Dimensions i Fitting Size inches/millimeters I Nominal Actual �_ �_ Outside Outs Diameter Diameter Approximate Weight Each Incheslmm Inches/mm C • E H P Lbsfkg 2'/2 2.875 3.75 2.75 1.68 5.2 65 .73.0 95 70 43 2,4 I 3 3.500 4.25 2.75 2,10 5.3 80 88.9 108 70 53 2.4 4 4.500 5.00 2.75 2.60 8.8 100 114.3 127 70 66 4.0 6 6.625 6.50 2.75 3.65 18.7 150 168.3 165 70 93 8,5 I MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. I Fitting Coatings: Orange enamel • Optional: Hot dip galvanized and others. I • I This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the ri to change product specifications, designs and standard equipment without notice and without incurring obligations. ® REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S.A. 1509 REV D I . Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e- mail:pickvic @victaulic.com V ictaulic Company of Canada • Phone: 905 - 884 -7444 • Fax: 905- 884 -9774 • e-mail: viccanada @victaulic.com Victaulic Europe • Phone:32 -9- 381 -1500 • Fax: 32.9- 380 -4438 • e -mail: viceuro @viclaulic.be Victaulic America Latina • Phone: 610 - 559 -3300 • Fax: 610- 559 -3608 • e -mail: vical@viclaulic.com jctaulic° I Viclaulic Asia Pacific • Phone: 65- 6235 -3035 • Fax: 65- 6235 -0535 • e -mail: vicap @viclaulic.com 1 . IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.O9 I VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Series 717R FireLock ® Check Valves I PRODUCT DESCRIPTION - Series 717R FireLock check valve incorporates a CAD - developed I _ design that is hydrodynamically efficient and available in 4 - 8" (100 - 200 mm) sizes. The Series 717R utilizes a totally rubber .. F , encapsulated disc to provide superior corrosion resistance. This f E n, _ - I single disc design incorporates a spring assisted feature for non - r / ,� . slamming operation. Approved for vertical or horizontal ' -411. - 'T installations, the Series 717R is designed to accept a riser check I r. kit. The kit consists of a 2" (50 mm) drain valve, 0 - 300 psi ',-_ _ (0 - 2065 kPa) gauges (2), gauge isolation valves (2), pipe nipples U) ® and pipe plugs. The Series 717R does not include the riser check I • kit unless specified and ordered. A welded -in nickel seat provides extra corrosion protection and leak -free sealing under as low as five (5) feet of head. The basic valve is factory tested and is UL /ULC Listed and FM Approved. The I 2" (50 mm) drain valve is UL /ULC Listed and FM Approved for services up to 200 psi (1370 kPa). Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted to flanged (ANSI CL.150) equipment using Victaulic Style I 741 Vic - Flange or Style 744 FireLock flange adapters on either end. • I DIMENSIONS A Q 1 Ail��ilI�1IIIF O /4 A 'c -1. A v V V ■ . < > A s. Valve Size Dimensions- inches/millimeters Aprx I Actual Wgt. Nominal Outside Ea. Diameter Diameter E - E Lbs. I nJmm him A B C D E F H J K L M N kg 4 4.500 9.63 6.25 4.00 3.75 14,25 6.88 6.70 10.45 11.25 2.00 2.00 5.25 28.0 100 114.3 245 159 102 95 362 175 170 265 286 51 51 133 12.7 I 5 5.563 10.50 6.50 4.25 3.75 14.75 7.38 7.37 11.87 12.75 2.15 1.88 5.25 35.0 125 141.3 267 165 108 95 375 188 187 302 324 55 48 133 15.9 139.7 mm 5.500 10.50 6.50 4.25 3.75 14.75 7.38 7.37 11.87 12.75 2.15 1.88 5.25 35.0 139.7 267 165 108 95 375 188 187 302 324 55 48 133 15,9 I 6 6.625 ' 11.50 7.63 5.38 3.75 15.50 8.03 7.70 12.20 13.00 2.38 2.13 5.25 46.0 150 168,3 292 194 137 95 394 204 196 310 330 61 54 133 20.9 165,1 mm 6.500 11.50 7.63 5.38 3.75 15.50 8.03 7.70 12.20 13.00 2:38 2.13 5.25 46.0 165,1 292 194 137 95 394 204 196 310 330 61 54 133 20.9 8 8.625 14.00 8.25 6.00 - 3.75 16.38 9.00 8.85 12.75 13.50 2.15 2.88 5.25 72.0 I 200 219,1 356 210 152 95 416 229 225 324 343 55 73 133 32,7 I 0 REGISTERED TRADEMARK OF VICTAUUC - 0 COPYRIGHT 2005 VICTAULIC - PRINTED IN U.S.A. - SKU WWCAS 6EWF22 1540 REV D I United Slates • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610 - 250 -8817 • e-mail: pickvic @victaulic.com Canada '• Phone: 905.884 -7444 • Fax: 905.884 -9774 • e -mail: viccanada @victaulic.com Europe • Phone: 32-9-381-1500 • Fax: 32 -9 -380 -4438 • e -mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e -mail: viceuro@victaulic.be ' ��� �', � ® Central and South America • Phone: 610 -559 -3300 • Fax: 610 - 559 -3608 • e -mail: vical @victaulic.com Australasia-. Phone: 86-21-58855151 • Fax: 86-21-58851298 • e -mail: vicap @victaulic.com I 10.09 FLOW CHARACTERISTICS II NOTE: Placement of check valves too close to sources of unstable flow will SERIES 717R shorten the life of the valve and polen- 6.0 l . l / tially damage the system. To extend 5.0 — FLOW OF WATER valve life, valves should be installed a 40 _ AT 601(16T) reasonable distance downstream from THROUGH VALVE pumps, elbows, expanders, reducers or other similar devices. Sound piping 3.0 , ^� ^ practices dictate a minimum of five (5) times the pipe diameter for general use. I ^ �r4 Distances between three (3) and five (5) N diameters are allowable provided the a 2.0 , • flow velocity is less than eight (8) feet I O h per second (2.4 mps). Distances less a • than three (3) diameters are not recom- 0 mended and will violate the Victaulic CC 1.0 product warranty. O 0 J a 03 / 02 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,00 20,000 800 3,000 8,000 I FLOW RATE - GPM MATERIAL SPECIFICATIONS • I Body: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Body Seat: Integrally welded on nickel alloy. Disc Coating: • Grade "E" EPDM EPDM (Green color code). Temperature range -30 °F to +230 °F ( -34 °C to +110 °C). Recommended for I cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F ( +30 °C) and hot +180 °F ( +82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, fully encapsulated in Grade "E" I elastomer. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Shaft: Type 316 stainless steel. Spring: All sizes Type 302/304 stainless steel. Shaft Plug: Carbon steel zinc plated to ASTM B -633. I Pipe Plug: Carbon steel zinc plated to ASTM B -633. . • I I This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. I Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Series 717R FireLock Check Valves I IPS CARBON _STEEL_PIPE EIRE PROLECTION VALVES 1 0.18 • FireLock® Butterfly ® us ® ILPCBI CE VdS tte y Valve I See Victaulic publication 10.01 for details . SERIES 705W � WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE A • ,-• _ I The Series 705W butterfly valve features an approved weatherproof actuator housing III approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc r;' 11 coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only, Series 705W valve is UL Listed I and.FM Approved for 300 psi/2065 kPa service. Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR • • Supervisory switches that monitor the valve in the fully open or fully closed position for I valves are available 2 — 12765 — 300 mm pre -wired (PW). OPTIONAL SUPPLY -SIDE TAP I Series 705W valves are available with a 1/2" (for 2'/2', 76.1 mm and 3" sizes) or W (4 = 12" /100 — 300mm sizes) NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. 1 /4" tap avail- able by special order. Contact Victaulic for additional information on tapped valves. I I MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A -536, coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTM A -536, various grades, EPDM coated. I • Disc Coating: • Grade "E" EPDM EPDM (Green color code). Temperature range —30 °F to +230 °F / -34 °C to +110 °C. Recommended for cold and hot water service within the specified temperature range plus a I variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +180 °F / +82 °C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. I Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel. Tap Plug: Carbon steel, plated. I 0 -Ring: EPDM Bracket: Carbon steel, painted. I Actuator: • 21/2 — 8765 — 200 mm: Bronze traveling nut on a steel lead screw, in a ductile iron housing. • 10 — 12 "/250 — 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing. I I JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved 1 • Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. jctaulid I REV_F 10.18_1 • IPS CARBON STEEL PIPE — FIRE PROTECTION VALVES 1 0..18 F eLLock® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE . 1 MATERIAL SPECIFICATIONS Handwheel: c• G'rul CA193 m 1 2'h -4 3.0 125 65 - 100 76.2 5 - 6 4.5 200 125 - 150 114.3 8 160 mm 250 200 10 - 12 9 250 - 300 225 "VdS version not UL Listed, FM Approved or LPCB Approved. 1 • 1 1 1 1 • 1 1 1 1 1 1 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED 119 THE USA.. ir'tauluC 10.18_2 REV_F I IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 9uveLock® Butterfly VaDve I SERIES 705W WITH'WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE I DIMENSIONS - c 41/) us ® I LPCBI Apra. Wgl. Sire Dimensions - inches /millimeters Each t gl323 I ilk 1111003 a id Hgt. I 21/2 2.875 3.77 8.76 - 4.21 6.08 3.00 0.00 ' 0.75 8.3 65 73.0 95.6 222.5 106.9 154.4 76.2 0.0' 19.1 3.8 76.1 mm 3.000 3.77 8.76 4.21 6.08 3.00 0.00 • 0.75 8.3 - 76.1 95.6 222.5 106.9 154.4 76.2 0.0 ' 19.1 3.8 3 3.500 3.77 9.40 0.08 4.21 6.08 3.00 0.00' 0.75 8.9 I 80 88.9 95.6 238.8 2.0 106.9 154.4 76.2 0.0' 19.1 4.0 4 4.500 4.63 10.84 0.07 6.01 6.98 3.00 0.73 1.13 14.9 100 114.3 117.6 275.3 1.8 152.7 177.3 76.2 _ 18.5 _ 28.7 6.8 139.7 mm 5.500 5.88 12.38 0.43 6.01 8.57 4.50 _ _ 21.0 I 139.7 149.4 314.5 10.9 152.7 217.7 114.3 - - 95 5 5.563 5.88 12.38 0.43 6.01 8.57 4.50 21.0 125 141.3 149.4 314.5 10.9 152.7 217,7 114.3 9.5 165.1 mm 6.500 5.88 13.41 1.00 7.51 9.32 4.50 1.60 1.88 26.5 165.1 149.4 340.6 25.4 190.8 236.7 114.3 40.6 47.8 12.0 I 6 6.625 5.88 13.41 1.00 7.51 9.32 4.50 1.60 1.88 26.5 12.0 150 168.3 149.4 340.6 25.4 190.8 236.7 114.3 40.6 47.8 8 8.625 5.33 16.50 1.27 9.65 10.98 6.30 0.00 • 0.68 43.0 200 219.1 135.4 419,1 _ 32.3 245.1 _ 278.9 160.0 0.0' _ 17.3 19.5 10 10.750 6.40 19.14 1.72 12.20 16.19 9.00 80.0 I 250 273.0 162.6 486.2 43.7 309.9 411.2 228.6 - - 36.3 12 12.750 6.50 21.54 2.66 14.25 17.22 9,00 102.0 300 323.9 165.1 547.1 67.6 362.0 437.4 228.6 46.3 On Centerline I # These dimensions apply only to a Series 705W Butterfly Valve with a'1 -inch NPT, supply -side tap 1. To prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero - Flex °, Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP -70 Rigid Couplings. If Victaulic flexible couplings are used. additional support may be required. 2. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. II 3. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only. Not permitted for use with plain end (IPS) pipe. 4. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. r7 1t r o = ( L l�l � 7'�D ■ � r 0 ■ Rr r 1 I �II� . . Supply Tap .. J . 9 7 ]]]],III IOW � S PP YTa r 9 � I*110 II N ,� Illill II I i I .Itli)11 • �J ��� N 1111 IIUIII' IIIIIII F 1 L A --1 E P F J L A - P U I 21 - 4- INCH /65 - 100-MM SIZES 5 - 12 -INCH /125 - 300 -MM SIZES I . I • I www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 1CtauIiC' I REV_F 10.18_3 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 I F rreLock® 3utteriDy VaDve 1 SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE 1 DIMENSIONS - VdS , . Apra. Wgt. I Sire Dimensions - inches /millimeters Each 022 am= Omega 11asI11213 Iil00a RBI Hgt. m m V 8' ° 7' 91" 'P 'VP B Q 8 21/2 2.875 3.77 8,76 _ 4.21 6.08 4.92 0.00 ' 0.75 8.3 65 73.0 95.6 222.5 106.9 154,4 125 0.0' 19.1 3.8 76.1 mm 3.000 3.77 8.76 - 4.21 6.08 4.92 0.00' 0.75 8.3 76.1 95.6 222.5 106.9 154.4 125 0.0' 19.1 3.8 3 3.500 3.77 9.40 0.08 4.21 6.08 4.92 0.00' 0.75 8.9 1 80 88.9 95.6 238.8 2.0 106.9 154.4 125 0.0' 19.1 4.0 4 4.500 4.63 10.84 0.07 6.01 6.98 4.92 0.73 1.13 14.9 100 114.3 117.6 275.3 1.8 152.7 177.3 125 _ 18.5 28.7 _ 6.8 139.7 ram 5.500 5.88 12.38 0.43 6.01 8.57 7.87 - - 21.0 _ 139.7 149.4 314.5 10.9 152.7 217.7 200 9.5 I 5 5.563 5.88 12.38 0.43 6.01 8.57 7.87 _ _ 21.0 125 141.3 149.4 314.5 10.9 152.7 217.7 200 9.5 165.1 mm 6.500 5.88 13.41 1.00 7.51 9.32 7.87 1.60 1.88 26.5 165.1 149.4 340.6 25.4 190.8 236.7 200 40.6 47.8 12.0 6 6.625 5.88 13.41 1.00 7.51 9.32 7.87 1.60 1.88 26.5 I 150 168.3 149.4 340.6 25.4 190.8 236.7 200 40.6 47.8 12.0 8 8.625 5.33 16.50 1.27 9.65 10.98 9.84 0.00' 0.68 43.0 200 219.1 135.4 419.1 32.3 245.1' 278.9 _ 250 0.0 ` _ 17.3 19.5 10 10.750 6.40 19.14 1.72 12.20 16.19 9.84 _ - W 80.0 250 273.0 162.6 486.2 43.7 309.9 411.2 250 36.3 _ I 12 12.750 6.50 21.54 2.66 14.25 17.22 9.84 _ - 102.0 300 323.9 165.1 547.1 67.6 362.0 437.4 250 46.3 • On Centerline * These dimensions apply only to a Series 705W Butterfly Valve with a 1/2-inch NPT, supply -side tap I 1. To prevent rotation of valves. it is recommended that Series 705W be installed with Victaulic Style 07 Zero - Flex °. Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP -70 Rigid Couplings. If Victaulic flexible couplings are used. additional support may be required. 2. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body. 3. Victaulic rooved end butterfly valves are permitted for use with grooved end pipe only. Not permitted for with plain (IPS) i 9 y IPS p g p p (IPS) y p use t p a end (I S) p pe. I 4. Series 705W valves are designed for ambient weather conditions as opposed to submersible service. _ - L- i i ■ B r II i 'h -NPT B : k- - 4- J,�.I 5 Supply �e7 �II� � 1' Supply I tW IIl■III [ II ■II Tr X11 i1 I't_� EN II' N mug \Ir 1111111' 11111111' I F r 1 L A-] E P J L A E P 21/2 - 4- INCH /65 - 100 -MM SIZES 5 - 12 - INCH /125 - 300 - SIZES I I I J 1 • 1 www.victaulic.com �CtaUIic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.. I 10.18_4 REV_F IPS CARBON STEEL PIPE — FIRE PROTECTION VALVES 1 0.18 FireLock® Butterfly Valve i SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE I PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. I Size Size . Actual Actual Nominal Outside Nominal Outside Size Diameter Equiv. Size Diameter Equiv. I Inches Inches Feetlm Inches Inches Feet /m mm mm of Pipe mm mm of Pipe 2' /z 2.875 5 6.500 8 65 73.0 1.6 165.1 mm 165.1 2.5 76.1 mm 3.000 5 6 6.625 8 76.1 1.6 150 168.3 2.5 3 3.500 .5 8 8.625 11 80 88.9 1.6 200 219.1 3.4 4 4.500 12 10 10.750 12 100 114.3 3.7 250 273.0 3.7 139.7 mm 5.500 12 12 12.750 14 139.7 3.7 300 323.9 4.3 5 5.563 12 125 141.3 3.7 I I I I I . I I . 1 I I www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. jctaulie 1 ' REV_F 10.18_5 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.18 I FireLock® Butterfly Valve I SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE PERFORMANCE C values for flow of water at +60 °F / +16 °C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C Values: I AP = Qz Where: C :: .Q = Flow (GPM) AP = Pressure Drop (psi) . 1 Q = C, x DP C = Flow.Coefflcient Size C„ Size C, Size C„ Actual Actual Actual I Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter Size Diameter Inches Inches Inches Inches Inches Inches mm mm (Full Open) mm mm (Full Open) mm mm (Full Open) 1 21/2 2.875 5.500 8 8.625 I 325 139.7 mm 1150 3400 65 73.0 139.7 200 219.1 76.1 mm 3.000' 325 5 5.563 1150 10 (0.750 5750 76.1 125 141.3 250 273.0 3 3.500 6.500 12 12.750 482 165.1 mm 1850 8300 80 88.9 165.1 300 323.9 I 4 4.500 6 6.625 100 114.3 600 150 168.3 1850 Formulas for K Values: i AP = Q Where: K Q = Flow C Q = K x „ET AP = Pressure (bar) lc = Flow Factor I Size K„ Size K,, Size K, Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter Size Diameter ! Inches Inches Inches Inches Inches Inches mm mm (Full Open) mm mm (Full Open) mm (Full Open) 21/2 2.875 5.500 8 8.625 280 139.7 mm 995 2940 65 73.0 139.7 200 219.1 3.000 5 5.563 10 10.750 76.1 mm 76.1 280 125 141.3 995 250 273.0 4975 I 3 3.500 415 165.1 mm 6.500 1600 12 12.750 7180 80 88.9 165.1 300 323.9 4 4.500 6 6.625 1 100 114.3 520 150 168.3 1600 I . .1 1 I 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.. jctaulic° 1 10.18_6 REV_F I IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10,18 FireLock® Butterfly I . SERIES 705W - WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE I . SWITCH AND WIRING 1. The supervisory switch contains two, single pole, double throw, pre-wired switches. P Y g p P 2. Switches are rated: I 10 amps @ 125 or 250 VAC /60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the 'open" position. 4. One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5. A #14 MTW ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL - I Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction I Si Normally Closed: (2) Blue Common: (2) Yellow I S2 Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe I UL LI TED IU CT,OW BO% FIR PAN TO END-0F.U RESSTOq ''/ CU OR NE %1 iNDKAIOR CONDOR 4 .4" CIRCUIT .J•_ $YAIG1 CONTACT RATING _r 11 CONDOR CONAECTORS �` IOA21 AND rI in MEM DSA AI I]S VDC _ 025 AT ISOVOC VI.RE NUTS BELL , OM ME MI OR YOLTAG: SOURCE rOR.Y i . SwItdr 1: leads per terminal Switch 2:1 lead Foe, terminal NOTE: The above diagram shows a connection between the common terminal (yellow — S1 and yellow- with - orange stripe — S2) and the normally closed terminal (blue — Si and blue- with - orange stripe — S2). In this example, the indicator light and alarm will stay on until the valve is fully open. I. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires 1 (e.g. brown with orange stripe). I • Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary • switch per NFPA 70 (NEC). • 1. . I . 1 ` www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. jiCtaulice I REV_F 10.18_7 I IPS CARBON STEEL_PIPE FIBEPJ3QTECTLON VALVES 10.18 1 7---- FireLock® Butterfly Valve y SERIES 705W WITH WEATHERPROOF ACTUATOR FOR 300 PSI SERVICE • 1 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications. designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve. Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1 -100 Victaulic Field Installation Handbook. i 1 1 1 1 • • i 1 1 1 iii 11 11 11111III11 111111111111111IIl WCAS- 6LUPQL For complete contact information, visit www.victaulic.com 1 10.18- 2466 REV F UPDATED 12/2006 ictaulIL•• VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY, ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.18 S P R I N K L E R S Y S T E M S M O N I T O R I N G WFD Series *� SYSTEM Waterflow Detector �� SENSOR® UL ULC /Canadian Models Models W FD40 I W FD20 W FD20A ; ; _ _� WFD25 WFD25A W FD30 -2 W FD30 -2A I WFD35 W FD35A W FD40 W FD40A i WFD50 WFD50A W FD60 W FD60A I W FD80 W FD80A _ '''"— .r. , Replacement Parts _ I ter: 1 A3008-00 Retard Mechanism / y ' A77 -01 -02 Terminal Block � I 546 -7000 Cover Tamper Switch Kit WFDW Cover Wrench p ` __e' , r ) WFD4 Replacement gasket kit k I i Product Overview I New WFD30 -2 models install in 2" System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, hole sizes sizes 2" through 8 ", and can be mounted in a vertical or horizontal position. I UL models are NEMA 4 rated Robust Construction. The WFD series consists of a rugged, NEMA 4 rated Sealed retard mechanism assures that enclosure. Designed for both indoor and outdoor use, the WFD series operates the retard is not contaminated by dust across a wide temperature range, from 32 °F to 120 °F. I and dirt when the cover is removed Reliable Performance. UL listed models are equipped with tamper resistant Visual switch activation permits cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) installer to accurately set retard under synchronized switches are enclosed in a durable terminal block to assure I noisy conditions reliable performance. Rugged, dual SPDT switches are enclosed in a durable terminal block False Alarm Immunity. The WFD series incorporates a mechanical retard fea- ture, which minimizes the risk of false alarm due to pressure surges or air I Accommodates up to 12 AWG wire trapped in the sprinkler system. In addition, the mechanical retard's unique 100% synchronization activates sealed design is immune to dust and other contaminants. both alarm panel and local bell Simplified Operation. The WFD series is designed to simplify installation. Two I simultaneously conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field - replaceable. I (21 ® ® T MEA o LISTED APPROVED approve i'lliiiii I I Engineering Specifications I Vane -type waterflow detectors shall be installed on system piping as designated on the drawing and /or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6" from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24" from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi* for 2" - 8" I pipes. The detector shall respond to waterflow in the specified direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mech- anism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or out- door use. I Standard Specifications Static Pressure Rating Conduit Entrances Service Use 450 PSI* Two openings for W conduit. One open, one Automatic Sprinkler: NFPA -13 knock -out type One or Two Family Dwelling: NFPA 13D I Triggering Threshold Bandwidth (Flow Rate) Residential Occupancies up to 4 Stories: NFPA 13R 4 -10 GPM Operating Temperature Range National Fire Alarm Code: NFPA -72 32 °F to 120 °F (0 °C to 49 ° C) Maximum Surge Warranty 18 Feet Per Second (FPS) Enclosure Rating* 3 Years NEMA 4 - suitable for indoor /outdoor use 1 Compatible Pipe: U.S. Patent Numbers Steel water pipe, schedule 10 through 40 Cover Tamper Switch 3,845,259 Standard with ULC models 4,782,333 Contact Ratings Optional for UL models, part no. 546 -7000 5,213,205 ■ Two sets of SPDT (Form C) I 10.0 A, 1/2 HP @ 125/250 VAC Shipping Weight 2.5 A @ 6/12/24 VDC WFD20: 4.2 lbs. WFD40: 5.2 lbs. WFD25: 4.3 lbs. W FD50: 6.3 lbs. Overall Dimensions Installed: WFD30 -2: 4.5 lbs. WFD60: 6.8 lbs. 3.75't WFD35: 4.7 lbs. WFD80: 7.5 lbs. ' • .. .1. a e°aam M e ,.� 1 PIP* saddle ;� !. u. Pd.,�vane = Model Width Model Width WFD20 4.6' WFMO 8.8' time WFD25 4.8'0 WFD50 7.8'0 WFD 95 5.2' WFD80 WFD 0.8 ' YAM: 8a. Table 35 _ 5.7'(L WFD80 10.8' Ordering Information UL Model Numbers ULC /Canadian Model Numbers Pipe Size Hole Size Part Number Description ' WFD20 WFD20A 2" 1 A3008 -00 Retard mechanism WFD25 WFD25A 2W 1W A77 -01 -02 Terminal block WFD30 -2 WFD30 -2A 3" 2" 546 -7000 Tamper proof switch kit WFD35 WFD35A 3 1 WFDW Tamper proof wrench for cover WFD40 WFD40A 4" 2" WFDN4 Gasket kit WFD50 WFD50A 5" 2" WFD60* WFD60A 6" 2" WFD80* WFD80A 8" 2" 1 *Maximum pressure rating 400 psi as approved by Factory Mutual. System Sensor Sales and Service I System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor — Far East System Sensor -- India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700 1 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800 /SENSOR2 System Sensor Europe System Sensor In Singapore System Sensor — Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Documents -on- Demand Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 800/736-7672 x3 www.systemsensor.com 192002 System Sensor. The company reserves the right to change product specifications without notice. A05- 0180. 008.04/02.047 I S P R I N K L E R I S Y S T E M S M O N I T O R I N G I SSM /SSV Series *Th_ SYSTEM Alarm Bells SENSOR® Models Available I UL /FM Models E 0 SSM 24 -6 SSM 24 -8 i ,` SSM 24-10 ( .5:1-...17-07„-_ ,; I SSV120 6 SSV120 8 / � , �.,r a-au r t` _? SSV 120-10 � � ':Cris, 20 I "� ULC /Canadian Models ' ` SSM 24 -6A i r SSM 24 -8A I SSM24 -10A SSV 120-6A 1 SSV 120-8A SSV 120 -10A I Weatherproof Back Box WBB I _ I Product Overview Approved for indoor and outdoor use System Sensor's SSM and SSV series bells are low current, high decibel notifi- Low current draw cation appliances for use in fire and burglary systems or other signaling appli- cations. High dB output Reliable Performance. The SSM and SSV series provide loud resonant tones. Three sizes available 6 ", 8 ", 10" The SSM series operate on 24VDC and are motor driven, while the SSV AC and DC models series operate on 120VAC utilizing a vibrating mechanism. DC models are polarized for use with Simplified Installation. For indoor use, the SSM and SSV series mount to a supervision circuitry standard 4 inch square electrical box. For outdoor applications, weather- proof back box, model number WBB, is used. Mount directly to standard 4" square electrical box The SSM and SSV series come pre - wired, to reduce installation time. The SSM series incorporate a polarized electrical design for use with supervision circuitry. I Engineering Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome I strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 6 "/8 "/10" (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi- I flush mounting. Outdoor surface mounted installations shall be weather- proof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum pro- jection of 2i4 ". Bells shall be located as shown on the drawings or as deter - ' 0 T mined by the Authority Having Jurisdiction. Bells shall be listed for ® MEA tsgry indoor/outdoor use by Underwriters Laboratories and the California State LISTED 41) ..gym approved III Fire Marshal, and approved by Factory Mutual and MEA. • . I Standard Specifications - Operating Temperature Range Termination Service Use I —31 °F to 140 °F Provided with 2 sets of leads for Fire Alarm Operating Voltage in /out wiring. General Signaling SSM series 24VDC Burglar Alarm I SSV series 120VAC Warranty 3 years • Gong Diameter Operating Maximum Current 111 Model (inches) Nominal Voltage Voltage Range (at Rated Voltage) Sound Output (dB) SSM24 -6 6 85 I SSM24 -8 8 24VDC 19.2 to 26.4VDC 0.024A 85 SSM 24 -10 10 86 SSV120 -6 6 83 I SSV120 -8 8 120VAC 96 to 132VAC 0.032A + 10% 78 I SSV120 -10 10 85 . Sound output measured at Underwriter Laboratories, as specified in UL464 I Ordering Information UL /FM Model Numbers ULC /Canadian Models Description I SSM24 -6 SSM24 -6A Bell, 6 ", 24VDC, Polarized, 85dba SSM24 -8 SSM24 -8A Bell, 8 ", 24VDC, Polarized, 85dba SSM24 -10 SSM24 -10A Bell, 10 ", 24VDC, Polarized, 86dba SSV120 -6 SSV120 -6A Bell, 6 ", 120VAC, 83dba I SSV120 -8 SSV120 -8A Bell, 8 ", 120VAC, 78dba SSV120 -10 SSV120 -10A Bell, 10 ", 120VAC, 85dba WBB Weatherproof Back Box for SSM and SSV series, when installed outdoors ' I I I System Sensor Sales and Service I System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fx: 91.124.637.3118 I Ph: 800 /SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor — Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Documents -on- Demand Fx: 44.1403.276501 .Fx: 65.6273.2610 Fx: 613.54.281.172 800/736 - 7672 x3 www.systemsensor.com I C 2003 System Sensor. The company reserves the right to change product specifications without notice. A05 -0260- 005.01/03.#1038 ® TDLCO www,tolco.com a brand of NIBCO• I Fig. 65 and Fig. 66 Reversible C -Type eam Clamps 3 4 and 1 4 Throat Openings I Size Range Material ® Function I Features I B D oak A , I Approvals (UL) AOWilk (cUL) �� I F / J I A ki Finish I Note Order y I B Fig. 65 D I Dimensions •Weights % � / D Rod Size Max. Rec. Approx. \� I , A C D E F Load Lbs. Wt. 100 /� F I v � � A I Fig. 66 ,-� Dimensions • Weights Rod Size Max. Rec. Approx. A C D E F Load Lbs. Wt. 100 I I El OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 i CUSTOMER SERVICE • 800.786.5266 www.tolco.com T'DLCO www.tolco.com i a brand of NIBCO• Fig. 98 - Rod Stiffener 4:DVS LISTED I Size Range Material • Function I Approvals UL cUL OS PD ( 1 Finish I Note Order y I Fig. 99 - All Thread Rod Cut to Length Size Range Dimensions • Weights I Rod Max. Rec. Load Lbs. Material ` t� ��� Size For Service Temps Maximum Temperature "(( 650 F 50 F 1 Finish Note Order y 1 Fig. 100 - All Thread Rod Full Lengths • 1 9 9 Size Range I Material ' Maximum Temperature "• , �li�� Finish . (II( /lj I Note l (f . Order y . I Dimensions • Weights ��� Max Rec. Load Lbs. ! ' / I Rod For Service Temps Approx. l / Size 650 F 50 F Wt. 100 j It( I I I ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 I www.tolco.com i ItTo Limo www.tolco.com a brand of NIBCD• I Fig. 200 - Trimline- Adjustable and anger Oils unto Size Range 4> Material I Function I Features . eatures .:: �: i 1 7 e i B B i 1 A I Approvals (UL) (cUL) 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE I t: Maximum Temperature I Finish Order y -.. __________+___—_______) \‘‘....... I Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size • Inch Metric A Load Lbs. Length 1 I • I OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I . 84 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 1 "DLCO" www.tolco.com a brand of NIBCO' - Fig. 4L I Longitudinal In -Line Sway race Attachment c ul. US USTED Size Range it:" I Material :lot o/'' Function , Approvals (UL) %, (cUL) Installation Instructions D A To Install 1 C 1 Finish Note Order y I I 41 00 - I 1 ! ` � o� o I DU_ O I DISCLAIMER NOT 114.1 Dimensions • Weights Olt Max. Rec. Approx. r% _ , !r Sizes A C D Size Load Lbs. Wt. 100 i it* 1 I OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 24 CUSTOMER SERVICE • 800.786.5266 111 www.tolco.com I FOLCD' www.tolco.com 0 a brand of NIBCD• 1 . Fig. 980 - Universal. Swivel Sway ' race Attachment OUS USTEO 1 Size Range Material I�� I Function " ` I Features concentric : ' H I vi \ 11141.14 I Installation A B I To Install I Approvals (UL) (cUL) I (OS PD) Note I UL (NFPA) Finish Note Order y PATENT 6,2 3,3 2 I /-2 Dimensions • Weights s ' , I A Max. Design Approx. ‘ � , Load Lbs. Wt. 100 I I DISCLAIMER ICI i OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I 158 CUSTOMER SERVICE • 800.786.5266 wwwlolco.com i FOLCcJ � WWWAO1CO.COm a brand Or NIBCCr I Fig. 1000 - Fast Clamp Sway .race Attachment- Qc O Size Range - 1 (UL) Material I Function Features I 1111 Installation s I 1t1 I To Install 1 Approvals (UL) _ I (cUL) `V (OS PD) I Finish , .._—\ Note i f \1.. Order y . \-......./ • I I DISCLAIMER NCZT higl I 4, ' OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 II CUSTOMER SERVICE • 800.786.5266 , www.tolco.com i d Western States 13896 Fir Street, Suite B Oregon City, Oregon 97045 Fire Protection Co. (503) 657-5155 FAX (503) 657 -5182 CCB #104570 June 13, 2008 City of Tigard - Building Division 13125 SW Hall Blvd. Tigard, OR 97223 - ATTN: Dan Nelson RE: Permit #: BUP2008 -00103 Site Address: 11462 SW Pacific Hwy. Project Name: America's Tire Company SUBJECT: proposal to design fire sprinkler system per FM Global Data Sheet 8 -3 - Rubber Tire Storage Dear Dan, We are requesting your acceptance of the application of FM Global Property Loss Prevention Data Sheet 8-3, Rubber Tire Storage, in lieu of NFPA #13 for the protection of tire storage at the above noted retail tire sales facility. The reason for this request is the discrepancy between the minimum 8' -0° standard for the ESFR sprinklers and the current steel construction. FM Global is an internationally recognized fire protection authority. Their data sheet 8-3 specifically includes tire storage in retail facilities. Protection requirements have been developed as a result of proprietary full -scale fire tests. NFPA 13 does not distinguish between tire storage in retail stores and large distribution warehouses. Both standards were developed as a result of full -scale fire tests conducted at the FM Global Test Center in Rhode Island. FM Global recommends a sprinkler system design density of 0.30 gpm/sq.ft. over the hydraulically most remote 2,500 sq.ft One level of in -rack sprinklers is required in both the single and double -row racks and hydraulically calculated • with the 6 most remote in -rack sprinklers each flowing at 30 gpm, as well as a 250 gpm hose demand is required for the calculations. Storage height Is limited to 16 ft, 8 ft aisles and a minimum clearance of 36-in. from top of storage to sprinkler deflector. No sprinkler protection under the open -grate mezzanine is required due to the possibility of cold soldering sprinkler heads when the tire racks are not full. Should you have any questions or comments please feel free to contact us. Thank you, Western States Fire Protection Co. A te-/-t i Darrell T. Fluit Project Manager