Loading...
Specifications 1 INTELLIKNIGHT FIRE ALARM CONTROL PANEL r( .5 . I ntel I i Knight® Model 5700 t Single Loop Addressable Fire Alarm Control System -11 ) ' The affordable addressable fire alarm E. N , control panel solution. ID r. ,; - IntelliKnight Model 5700 is a 50 point class leading single loop , V addressable fire alarm control /communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1 -800- 446 -6444, or in Minnesota, call 763 -493 -6435. • Description • RS -485 bus provides communication 5700 performs drift compensation and to system accessories calibration checks on each of the • Upload or download programming, ---1,-1,••1111 C sensors in the system. event history, or detector status 7 — -" • The basic IntelliKnight 5700 system onsite or from a remote location can be enhanced by adding modules using a PC and 5660 Silent Knight such as 5860 remote annunciator, Software Suite (SKSS) 5824 serial /parallel printer interface • Improvements in SKSS deliver five module (for printing system reports), times faster upload /downloads • and 5496 intelligent power module. • Built -in RS -232 interface for 5700 also features a powerful built -in programming via PC dual line fire communicator that allows • Built -in Form C trouble relay rated at • for reporting of all system activity to a 2.5A at 27.4 VDC monitoring location. • Two built -in Form C programmable InlrlliF night' Features relays rated at 2.5A at 27.4 VDC - ;;; e "` • Up to 50 addressable points • Programmable date setting for P P Daylight Saving Time • Up to 125 zones and 125 output Model 5700 groups Electrical Specifications • Uses standard wire —no shielded or Primary AC: 120 VAC, 60 Hz, 1.5A Telephone Requirements: twisted pair required T Accessory Load: 2.5A @ 27.4 FCC Part 15 and Part 68 approved • Built -in digital communicator. Type of Jack: RJ31X (two required) • Central station reporting by point or Notification Power: 2.5A @ 27.4 VDC, power - limited by zone Approvals • Supports Class B (Style 4) and Class Standby Current: 200 mA NFPA 13, NFPA 15, NFPA 16, NFPA A (Style 6 or 7) configuration for SLC Alarm Current: 325 mA 70, & NFPA 72: Central Station; • Distributed, intelligent power Notification /Aux Power Circuits: Remote Signalling; Local Protective • Drift compensation 2.5A @ 27.4 VDC per circuit, Signalling Systems; Auxiliary Protected power - limited Premises Unit; & Water Deluge • 13 pre - programmed output cadences Battery Charging Capacity: 7.0 -35.0 AH (including ANSI -3.41) and 4 Releasing Service. Suitable for programmable outputs Battery Size: 7 AH max. allowed in automatic, manual, waterflow, sprinkler • • Notification circuits configurable as 1 FACP cabinet. Larger capacity supervisory (DACT non - coded) 9 batteries can be housed in an RBB signalling services. Class A (Style Z) or 2 Class B (Style accessory cabinet. Y), or auxiliary power for resettable, Other Approvals: UL Listed; constant, or door holder power Mechanical S CSFM 7170 -0559: 144; • Built -in synchronization for AMSECO, Dimensions: MEA 429 -92 -E Vol. XVI. Gentex®, Faraday, System Sensor® 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) SILENT and Wheelock® appliances • Built -in annunciator with 80- character Weight: 11.5 lbs. (5.2 kg) KNIGHT . LCD display Color: Red by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL PANEL C SLC Detectors SLC Modules 5880 LED/I0 Module . SD505 -APS Model SD500 -AIM Features 40 LED Addressable photoelectric smoke detector. Dry contact input module for use with outputs, 8 normally • normally open dry contacts. It features an open dry contact inputs SD505 - AIS indicator LED to show alarm status. and one piezo output. 1 J Addressable ionization smoke detector. SD500 -MIM 5865 -3 and 5865 -4 SD505 -AHS Remote LED Mini dry contact input module is a small Absolute temperature heat detector that Annunciator version of the SD500 -AIM. For use with pull goes into alarm immediately if the P Features 30 temperature exceeds the programmable trip stations and other normally open dry contact Programmable LED (15 point. Trip point range from 135 °F -150 °F inputs. red and 15 yellow) outputs and a piezo (0 °C- 37 °C). SD500 - ANM sounder. The 5865 -4 adds a silence and SD505 - 6AB Addressable notification module providing a reset switch to the package. Six inch base for use with detector heads single Class A or Class B notification circuit 5883 Relay Board SD505 -APS, SD505 -AIS and SD505 -AHS. on the SLC. Features 10 general purpose Form C relays. SD500 - ARM Used with 5880 module. SD505 - 4AB Addressable relay module that features two 5824 Serial /Parallel Printer Four inch base for use with detector heads Form C output relays. Provides indicator Interface Module SD505-APS, SD505 -AIS, and SD505-AHS. LED to show output status. Provides one parallel and one RS -232 serial SD505 - 6SB SD500 - SDM port for connecting a printer to 5808. Use to Six -inch sounder base for use with existing Two-wire detector input module. Allows for print a real -time log of system events, sensor and base. Operates In single and the connection of conventional 2 -wire detector status reports, and event history. multi- station modes and /or as a system detectors on the SLC loop. Requires two Interfaces with building control system. sounder. Requires 2 additional wires for additional wires for power. power. Miscellaneous Accessories SD505 -61B SD500 -LIM 5660 Silent Knight Software Suite Short circuit isolator base for SD505 -AHS, A short circuit isolator module for SLC devices. When a short occurs on the SLC User - friendly Windows software for remote SD505 -APS, and SD505 -AIS detectors. loop, it is detected as a trouble, but all SLC programming of 5700s using a PC. Upload SD505 - 6RB devices protected by the isolator module and view panel account information, event Six -inch relay base for use with existing continue to operate. history, and detector status. sensor and base. Provides one Form C SD500 - LED 5670 Silent Knight Software Suite contact. An LED driver capable of driving 80 LEDs End -user facility management software SD505 - ADH through the SLC loop. Up to 40 allows viewing of detector status and event Duct housing that detects smoke in HVAC SD500 -LEDs can be used per system. history via modem or direct connection. ducts. RBB S -BUS Accessories SD505 - ADHR -- — -- — — — Remote Battery Box Accessory Cabinet. Use Duct detector base with relay. Provides 5860/R Remote Fire Annunciator if backup batteries are too large to fit into Form C alarm contact. For use with Features the same 80 character backlit LCD FACP cabinet. Dimensions: SD505 -APS and SD505 -AIS sensors. display keypad and firefighter's key switch 16" W x 10" H x 6° D Compatible with SD505 -DTS remote test as the 5700. The system can be fully (406 mm W x 254 mm H x 152 mm D) switch. programmed and operated from any 5860. SD505 - DTS SD500 PS /SD500 - PSDA 5860 is gray and 5860R is red Remote test switch that provides remote key SD500 -PS is a single action pull station and 5496 Intelligent Power Module operated test function and annunciation of SD500 -PSDA is a dual action pull station. A 6 amp notification power expander that detector alarm with SD505 -ADHR. provides four additional power - limited notification appliance circuit outputs. I ' I - ) ® +' .� II f... ID 403.11 ®xe.n eoMIs..e plitirKI 1 PI . wmwn II r I am ♦-". I rr I I17.4..5.0 MY...s �(�q�� e Kohn rs�wr. 71310340.11 WIMPS SIMOSJON =WIN 6131164011 - 5700 5496 SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA T KNIGHT keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350392 Rev. D, 04/06 * subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator , ,, *. Bring the power to control an IntelliKnight ' �' ` fire alarm control panel to every area l .. within your facility. El: ._ a ) Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator "` provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 -446 -6444, or in Minnesota, call 763 -493 -6435. Description • Available in red or light gray ■ Features include an 80- character • Support for simultaneous use of backlit LCD providing easy -to- multiple 5860s understand system messages. The • RS-485 interface to panel IIIIIIII annunciator is ergonomically • Operation and appearance is " designed with over -sized buttons identical to 5860 built-in .,) for the most frequently used annunciators R► a _h, features, like Reset and Silence. • On -board piezo sounder audibly r 1,r ,ll 7 Ia . In addition to status messages indicates alarms, troubles, and .. 4,• till oi supervisories displayed on the LCD, there are Fiv five • LEDs for alarm, supervisory, ' Five status LEDs for alarm, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions 5860 status. • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Color to match virtually any decor and gauge and number of devices on 5680R: Red red for applications where the SBUS) 5680: Gray • annunciator must stand out. The UL listed, complies with NFPA 72 Environmental annunciator enclosure can be • CSFM approved Operating Temperature: 32 °F – surface or flush mounted. A trim Electrical Specifications 120 °F (0 °C – 49 °C) ring kit is available for surface Operating Voltage: 24 VDC Humidity: 10% – 93% non - mounting. Standby Current: 20 mA max condensing Features Alarm Current: 25 mA Approvals • 80- character backlit LCD display Wiring Distance: 6,000 max. from NFPA 72; UL Listed; - (4 lines with 20 characters on FACP de endin on wire gauge each line) ( p 9 9 9 CSFM 7170 -0559: 135; • Tactile and audible feedback and number of devices on the MEA 429 -92 -E Vol. IX; SBUS) FM Approved - • Accepts user codes or fire System: 8 Max Per S fighter's key Y " • Larger keypad buttons for system Mechanical Specifications SILENT reset and silence Physical 9.1" W x 7.4" H x 1.5" D KNIGHT • Install up to eight 5860s per (23.1 W x 18.8 H x 3.8 D cm) ` FACP Shipping Weight: 2.8 lbs (1.3 kg) by Honeywell r INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator • ' 1 Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP =,gin MIN : 6iiiiil• J ' � auo 1 . (� ooa a. w n; * .1.1: `" A9 41 = to 5860 5860 5860 } Up to Eight 5860s Per System Compatible IntelliKnight FACP Compatibility Ordering Information Accessories IntelliKnight 5820XL FACP 5680R Remote Annunciator 5860TR Red Trim Ring IntelliKnight 5808 FACP Four line LCD annunciator with 20 For surface mounting. characters per line. Red. IntelliKnight 5700 FACP 5860TG Gray Trim Ring 5680 Remote Annunciator. For surface mounting. Four line LCD annunciator with 20 characters per line. Gray. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA c KNIGHT keep our mdo specific applications product infor or anticipate ation up tto - all requirements ate and accurate. All specifications We cannot c are all FORM# 350224 Rev C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY . Addressable A ; Photoelectric Type ,. . Smoke Detector . Ni. ., Detect smoldering fires quickly and get 1113 r raf help fast with IntelliKnight® photoelectric ' smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS The light received is converted into Analog / Addressable an electronic signal. Under normal - Photoelectric Type conditions, the status LED blinks 's Smoke Detector approximately every 15 seconds, The SD505 -APS is particularly indicating that the head is •ila so suited to detecting dense smoke communicating with the loop. The �.. typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials Features which tend to smolder and produce • Low profile, 2 inches, including SD505 -APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the • Built -in fire test feature Alarm: .55 mA WindowsTM based downloading Simple detector calibration Ambient Temperature: 32 °F to 120 °F • software). testing through the control panel (0 °C to 49 °C) Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable Air Velocity: 0 300 FPM from the pulsing light source. In the • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505 -6AB detector and light is reflected from (Sold Separately) (6" Base) the smoke particles to the receiving CSFM approved SD505 -4AB element. • MEA approved (4" Base) • FM Approved SILENT TS KNIGHT D by Honeywell INTELLIKNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15/16" ot °---- 1 �\ Diameter = 3- 15116" / j e 15 11 M ( CD •■ s ! at Height = 2 Inches, ' • Including base —7-1 •,- La- Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY S D500 -PS and SD500 -PSDA `' a = Addressable Pull-Station _ • 1 we k`� �". IntelliKnight's addressable pull stations combine fast response with pin -point location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA • Corrosion - resistant gold - plated contacts. 4 PULL Addressable Pull • Reflective label makes it easier Station to locate in low light { . The SD500 -PS is a single action Operation } (4, . ' t addressable fire pull station, and The SD500 -PS /PSDA single action ., _ •`/ ti the SD500 - -PSDA is a dual action pull stations are operated by a pull ) K , addressable fire pull station. The on the front pull cover of the SD500 -PS /PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable FIRE on back of the pull station allows module, is released as the pull [' interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500 -PS /PSDA is down and can be seen up to 100 ..[. designed for indoor use in non- feet away. The pull station is reset explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold - plated to avoid relocking the station with a reset r -- tiILk \-I risk of corrosion. The SD500- key. The reset keys are the same IS I K Y I C I rr PS /PSDA has been tested by UL keys used on Silent Knight �'—_ for compliance to the requirements enclosures. of the Americans with Disabilities The SD500 -PS /PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32 °F to 120 °F • UL Listed communicating with the loop. The (0 °C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS -SMBB • Key reset (Same key as Silent set the unique address. . Knight enclosures) • Specifications • Surface mount back box Operating Voltage: 24VDC SILENT available Standby Current: .55mA KNIGHT • Terminals - accept up to 14 Alarm Current: .55mA gauge wire r A, .4 .,.mf INTELLIKNIGHT ACCESSORY SD500 -PS and SD500 -PSDA Addressable Pull- Station )` I. Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. 4 FACP .. Y`v `\ \ ' e . pp .�q{,.ppp � - ..., F, ., � .9 `_ _v . s, S \ , •, S. ! CEl ,Y C ," -- - Gme�sr�. �, C"o a�¢M 1 `- • -- . -.% +-- , \ ... f : Vi —'' xouc,. .z:,......,1 raea,.,.w I I I \ � I .Y� i 1 ‘., ' ' \ - -- _-�yA \ A - - - -- \-t • ` N 1� - ir e' sac. a O r.cr - .l • C • \ I srr o r. fM..PAlt - p 'S i S. I \ 1 \� Wiring ■ —, I i r I I 24W I 1 � 1 '- -- f 0 I . . -- 0. 9 1 Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box ; l' _ sut e• - - SD500 -PSDA Lim ■ i F-_A Installing SD500 -LK electrical ei Ono be Dimensions 1 _ f SILENT t KNIGHT s. A h2 ....i Co rc.-rr 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 763 - 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763 - 493 -6475 - World Wide Web: http: / /www.silentknight.com Copyright © 2003 Silent Knight 1, Series Z Strobes, Horns and Horn Strobes - SNAP l �' COOPER Wheelock Features an easy snap on base designed Strobes to simplify the installation and testing of strobes, horns and horn strobes. F FIR Available features and options: Color: Red or white Mounting: Wall or ceiling Wall Mount Strobe UL Max. Current 15cd 30cd 75cd 110cd ZRS - MCW -FR Red 4085 24 VDC 0.060 0.092 0.165 0.220 EZ mount SNAP design ZRS- MCW -FW White 0302 ZRS - MCWH -FR Red 5242 Universal mounting plate - single ZRS- MCWH -FW White 0303 UL Max. Current 135cd 185cd plate for wall and ceiling mount in- Ceiling Mount Strobes 24 VDC 0.300 0.420 stallations ZRS -MCC -FW White 0309 Disposable cover to protect base ZRS- MCC -FR Red 0308 UL Max. Current 15cd 30cd 75cd 95cd ZRS-MCCH-FW White 0314 plate ZRS- MCCH -FR Red 5240 24 VDC 0.065 0.105 0.189 0.249 Strobes produce 1 flash per sec- UL Max. Current 115cd 177cd and over the Regulated Voltage 24 VDC 0.300 0.420 Range Horns and Horn Strobes R E Wall or Ceiling Mount Horn ZNH -R Red 0300 ZNH -W White 0301 Wall Mount Horn Strobe ZNS- MCW -FR Red 0304 ZNS - MCW -FW White 0305 ZNS - MCWH -FR Red 0306 ZNS- MCWH -FW White 0307 Ceiling Mount Horn Strobe ZNS -MCC -FW White 0311 ZNS- MCC -FR Red 0310 ZNS - MCCH -FW White 0313 ZNS - MCCH -FR Red 0312 UL Max. Current 15cd 30cd 75cd 110cd High (95) dBA 24 VDC 0.074 0.107 0.184 0.244 Low (90) dBA 24 VDC 0.066 0.101 0.177 0.232 UL Max. Current 15cd 30cd 75cd 95cd High (95) dBA 24 VDC 0.082 0.124 0.209 0.275 • Low (90) dBA 24 VDC 0.071 0.114 0.201 0.261 • UL Max. Current UL Max. Current Audible 115cd 177cd 24 VDC 12 VDC High (95) dBA 0.350 0.477 High (95) dBA 0.044 0.021 Low (90) dBA 0.306 0.429 Low (90) dBA 0.018 0.012 1 -2 09/06 (800) 631 -2148 • www.cooperwheelock.com AZ AFAA NAC Voltage Drop Calculator for Audio / Visual devices This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by, and the results do not exceed the limits set by the respective jurisdiction I I _ Point to Point Method End of Line Method Load Centering Method Project Name ATC CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 4/16/20081 Circuit Number N1 -1 Totals Voltage Totals Voltage Totals Voltage Area Covered Current Distance Drop Current Distance Drop Current Distance Drop Nominal System Voltage 20.4 0.686 134 0.23 0.686 134 0.564 0.686 134 0.282 Minimum Device Voltage 16 End of Line Voltage 20.17 End of Line Voltage 19.84 End of Line Voltage 20.12 Total Circuit Current 0.686 Wire Ohm's Percent Drop 1.15% Percent Drop 2.77% Percent Drop 1.38% Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Distance from source to 1st device 9 14 3.07 Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance o f circuit 14 3.07 18 =7.77 16 =4.89 14 =3.07 12 =1.981 10=1.241 Enter current in amps. Distance 18 -14 Awg =Solid Conductors 12 -10 Awg r = Stranded Conductors .150 = 150 ma from Voltage Notes: Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires (Positive and Negative) Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then Device 1 0.092 9 20.36 0.038 0.19% the manufactures listed minimum operating voltage (IE: rated operating voltage 20 -32 VDC). Device 2 0.092 3 20.35 0.049 0.24% 1 Device 3 _ 0.074 2 20.34 0.055 0.27% Device Manufacturer WHEELOCK Device Manufacturer WHEELOCK Device 4 0.107 20 20.29 0.108 0.53% Current 1 Current Device 5 0.107 32 20.23 0.171 0.84% Horn Strobes @Rated Strobe Only @Rated Device 6 0.107 28 20.19 0.207 1.02% Model # Candela Voltage Model # Candela Voltage Device 7 0.107 40 20.17 0.234 1.15% ZNS- MCW -FR 15 0.074 ZRS- MCW -FR 15 0.060 • END 20.17 0.234 1.15% 30 0.107 30 0.092 END 20.17 0.234 1.15% 75 0.184 75 0.165 END 20.17 0.234 1.15% 110 0.244 110 0.22 END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% END 20.17 0.234 1.15% • END 20.17 0.234 1.15% END _ 20.17 0.234 1.15% Totals 0.686 134 End of Line Voltage 20.17 ■ AZ AFAA NAC Voltage Drop Calculator for Audio / Visual devices This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by, and the results do not exceed the limits set by the respective jurisdiction I I Point to Point Method End of Line Method Load Centering Method Project Name ATC CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 4/16/20081 I Circuit Number N2 -1 Totals Voltage Totals Voltage Totals Voltage Area Covered Current Distance Drop Current Distance Drop Current Distance Drop Nominal System Voltage 20.4 1.297 200 0.83 1.297 I 200 1.593 1.297 200 0.796 Minimum Device Voltage 16 End of Line Voltage 19.57 End of Line Voltage 18.81 End of Line Voltage 19.60 Total Circuit Current 1.297 Wire Ohm's Percent Drop 4.05% Percent Drop 7.81% Percent Drop 3.90% Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Distance from source to 1st device 20 14 3.07 Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance o f circuit 14 3.07 18 =7.771 16 =4.89 14 =3.07 12 =1.981 10 =1.24 Enter current in amps. Distance 18 -14 Aw• = Solid Conductors 12 -10 Aw = Stranded Conductors .150 = 150 ma from Voltage Notes: I I I I Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires (Positive and Negative) Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then Device 1 0.107 20 20.24 0.159 0.78% the manufactures listed minimum operating voltage (IE: rated operating voltage 20 -32 VDC). Device 2 0.060 8 20.18 0.218 1.07% Device 3 0.107 7 20.13 0.266 1.31% Device Manufacturer WHEELOCK Device Manufacturer WHEELOCK Device 4 0.244 17 20.03 0.373 1.83% I Current Current Device 5 0.244 50 19.79 0.612 3.00% Horn Strobes @Rated Strobe Only @Rated Device 6 0.244 44 19.64 0.757 3.71% Model # Candela Voltage Model # Candela Voltage Device 7 0.107 14 19.62 0.782 3.83% ZNS- MCW -FR 15 0.074 ZRS- MCW -FR 15 0.060 Device 8 0.184 40 19.57 0.827 4.05% 30 0.107 30 0.092 END 19.57 0.827 4.05% 75 0.184 75 0.165 END 19.57 0.827 4.05% 110 0.244 110 0.22 END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% END 19.57 0.827 4.05% Totals 1.297 200 End of Line Voltage 19.57 •