Correspondence *Aid 1 �f May 24, 2004 o ' I CITY OF TIGARD Jim Markman Olt Markman Inc. 9955 SE Ash Street Portland, OR 97216 RE: NEW ROOFTOP UNIT & INTERIOR MODIFICATIONS Mechanical Permit: MEC2004 -00287 Occupancy Type: B /S -1 Tenant Name: Consolidated Supply Construction Type: VN Address: 7337 SW Kable Lane The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The submitted plans are approved subject to the following. 1. The rooftop unit shall have it's attachment to the structure designed in accordance with the Building Code. SEE STRUCTURAL PERMIT BUP2004 -00223 for unit anchorage. 2. Inspector to field verify Hydronic Piping materials comply with section 1202 OMSC. SEE ATTACHED COPY OF TABLE 1204.4 & 1204.5 3. Smoke detectors shall be installed in the return air system. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 4. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 5. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room and within six feet of the appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC 6. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 7. Appliances serving different areas of a building other than where they are installed shall be permanently marked in an approved manner that uniquely identifies the appliance and the area it serves. 304.10 OMSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 8. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 9. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 10. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and proce . ing the documents. Respect V V. Bl• • , Senio /' ans Examiner I