Loading...
Specifications : a-Ot 5 Od 3 76 October 1, 2000 Sprinkler 11 a ,� . ®.. . T MICROMATIC AND C .': - '-.) NIKII - TECHNICAL DATA' MicromaticHP STANDARD RESPONSE SPRINKLERS 1. PRODUCT NAME • Viking Micromatic Model M and Micro- y ....;-;•;.•:. ;" . •V i, maticHP Model M Standard Response — � � Glass Bulb Style Sprinklers s i : t t , • Available Styles: Upright, Pendent, �' 0!: and Conventional �" ' . 2. MANUFACTURER %: I ��, IAU J The Viking Corporation 1 11 4,. `z-� 210 N. Industrial Park Road - � m..r` Hastings, Michigan 49058, U.S.A. ' ( � .� l` • Telephone: (616) 945-9501 :,., ©STY OF Upright ° Pendent Conventional (877) 384 -5464 " Fax: (616) 945-9599 ••••,..q. Bushi f rHi g t i � Pressure3 Sprinklers): AVAILABLE FINISHES e -mail: techsvcs@vikingcorp.com Brass UNS- C36000 Brass, Bright Brass, Chrome-Enloy®(pat- 3. PRODUCT DESCRIPTION Bulb: Glass, nominal 5 mm diameter ents pending), White Polyester (White Viking Micromatic and MicromaticHP Seal: Teflon ®Tape Poly finish for P/N 10139 only), Navajo Standard Response Sprinklers are small Spring: Nickel Alloy White Polyester, Black Polyester (Black thermosensitive glass -bulb style spray Screw: Brass UNS- C36000 Poly finish for P/N 10139 only), and Black sprinklers available in several finishes, Pip Cap and Insert Assembly: Copper Teflon® in all temperature ratings; temperature ratings, and orifice sizes to UNS- C11000 and Stainless Steel Wax-Coated Brass or Wax over Polyester meet design requirements. The small UNS- S30400 for sprinklers with temperature ratings frame and rugged 5 mm glass bulb provide a Sprinklers with Teflone Coating through 286 °F (141 °C). pleasing appearance. Used in conjunction • Wax Over Polyester unavailable for Sprinkler Base P 9 pP 1 Spring: Nickel Alloy, exposed Part Numbers 09992, 09993, 09994, and 09995. with one of the various corrosion- resistant Screw: Brass UNS- C36000 ACCESSORIES coatings, the units provide protection Pip Cap and Insert Assembly: Copper Sprinkler Wrenches: - against many corrosive environments. In UNS- C11000 and Stainless Steel addition, the Polyester finishes and Teflon® UNS- S30400, Teflon® coated A. Standard 10 coating can also be used in decorative ap (available a ablle wrench: e since 2000) or OS000CW /B Part No. l 10896W/B - longer available er Spr w Polyester Coating or no plications where colors are desired. (no 9 ) During fire conditions, the heat - sensitive Poly Finish B. Wrench for coated and recessed sprin- liquid in the glass bulb expands, causing Spring: Nickel Alloy, exposed klers: P/N 07398W" (available since 1990). the bulb to shatter, releasing the pip -cap Screw: Brass UNS- C36000 • A 112' ratchet is required (not available from Vi- and sealing spring assembly. Water flow- Pip Cap and Insert Assembly: Copper king). ing through the sprinkler orifice strikes the UNS - 011000 and Stainless Steel Refer to the "Sprinkler Accessories" section sprinkler deflector, forming a uniform spray UNS- S30400 of the data book. pattern to extinguish or control the fire. Sprinkler Nom. Sprinkler Ceiling Temper at Sprinkler Bulb • Viking Standard Response Glass -Bulb Style Temperature Temp. Rating Max. Ambient Max. Recommended Sprinklers may be ordered and/or used as Classification (Fusi g Point) Temp. Allowed Ambient Temp.2 . Color open sprinklers (glass bulb and pip -cap Ordinary 135 °F (57 °C) 115 °F (46 °C) 100 °F (38 °C) Orange _ assembly removed) on deluge systems. Ordinary 155 °F X68 °C) 135 °F (57 °CL 100 °F (38 °C) Red _ 4. TECHNICAL DATA • . LISTINGS AND APPROVALS I - III - a'. - Mks rliibJ ' a r ' . - -. Refer to the charts on pages 11 b d. ' - in - • •- - MAP 2 " i 3Cf:IQ.S� it. - trigata. - s(ei� :, , Minimum operating pressure: 7 psi (48,3 kPa). High : • 266 °F (130 °C) Blue A - ..I .r •r ° ° r r , ► - Glass -bulb fluid temperature rated to s s rr .r :r • ° ;r • -65 °F ( -55 °C). Sprinkler Finishes: Brass, Bright Brass, Chrome- Enloy (patents pending), White Polyester Rated Water Working Pressure: (White Poly finish for P/N 10139 only), Navajo White Polyester, Black Polyester (Black Poly Sprinkler Base Part Nos. 09992, 09994, finish for P/N 10139 only), and Black Teflon 10175, and 10176 are rated for use Corrosion - Resistant Coatings °: White Polyester (White Poly finish for P/N 10139 only), Na- with water working pressures vajo White Polyester, Black Polyester (Black Poly finish for P/N 10139 only), and Black Tef- Ion in all temperature ratings. Wax- Coated Brass and Wax over Polyester finish for sprin- ranging from the minimum 7 psi klers with the following temperature ratings: (48,3 kPa) up to 250 psi (1 724 kPa) 135 °F (57 °C) Off-White Wax 175 °F (79 °C) Brown Wax 212 °F (100 °C) Brown Wax for high - pressure systems. High- 155 °F (68 °C) Lt. Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax pressure (HP) sprinklers can be 1 Based on National Fire Prevention and Control Administration Contract No. 7- 34860. Identified by locating the number 2 Based on NFPA -13. Other limits may apply, depending on fire loading, sprinkler location, and "250" on the deflector. 3 other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. All other Part dos, not mentioned 4 The temperature rating is stamped on the deflector. The corrosion - resistant coatings have passed the standard corrosion test required by the ap- above are rated to a.maximum 175 proving agencies indicated on pages 11 b -d. These tests cannot and do not represent all psi (1 207 kPa) wwp. possible corrosive environments. Prior to installation, verify through the end -user that the Factory tested hydrostatically to 500 psi (3 coatings are compatible with or suitable for the proposed environment. The coatings indi- 448 kPa). cated are applied to the exposed exterior surfaces only and, therefore, the sprinklers cannot , 1 be used as open sprinklers. Note that the spring is exposed on sprinklers with Polyester fin - • Spring: U.S.A. Patent No. 4,167,974 ishes and Teflon® coatings. SPRINKLER MATERIALS 5 Sprinklers of Ultra -High temperature rating are intended for use inside ovens, dryers, or simi- Frame: Brass Castings UNS- C84400 lar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambi- Deflector: Brass UNS- C26000 ent temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 6 Wax Over Polyester unavailable for Sprinkler Base P /Ns 09992, 09993, 09994, and 09995. Note: Units of measure in parentheses may be approximations. New format replaces page 11 a -d, dated May 18, 2000 and page 31 Form No. F_100397 a -d, dated May 27, 1999. Refer to technical data page SR1 -2 for general care, installation, and maintenance information. Sprinkler. 11 b October 1, 2000 : ' MICROMATIC AND NIKI: ,, 'TECHN DATA, ° MicromaticHP STANDARD 0 RESPONSE SPRINKLERS • Approval Chart Temperature KEY Micromatie Standard Response Finish Pendent Sprinklers Maximum 175 PSI WWP • Stan•ard Oritic- Thread Max. Nominal Overall Sprinkler Sprinkler Sprinkler Listings and Approvals 5 31311 7 f7 Style Base P /N I.D. No.9 ITt M1114.. i><f_ia1>� iTI•___ _ Z•T7 Pendent 10139 VK102 A3, B4, C6, A3, 64, C6, A9, D10, F9 A3, B4, C6 .t. :, •F.1, :: La •" - _, 1/2 -- 175 Pendent 10223 VK202 8.0 11,5 2.4 Si A3, C6, A3, 64, C6, A7, D5, F7 A3, B4 -- -- F7 F7 3/4 -- 175 Pendent 10142 VK202 8.0 11,5 2.4 61 A3, C6, A3, 64 C6, A7, D5, F7 A3, B4, C6 A2 A1, B: -- 15 175 Pendent 10187 VK202 -- 11,5 2.4 61 A3, C6, A3, C6, D5 -- -- A1, B: -- • - .. - . 1 1 . • -- • . • _ t -- _ _ • • S allOr'fice 1/2 -- 175 Pendent 10221 VK003 2.8 -- 2.3 58 A3, C6, A3, C6, B7, B5 A3, B4 -- -- F7 F7 1/2 -- 175 Pendent 10222 VK004 4.2 -- 2.3 58 A3, C6, A3, C6, -- A3, B4 -- -- -- • - .. - . 1 . 1 1 -- -- -- -- -- _ _ • • -- 15 175 Pendent 10188 VK004 4.2 -- -- -- A3, 84, C6, A3, B4, C6, _ F7 F7 • 15 175 Pendent 10189 VK003 2.8 -- -- A3, B4, C6, A3, B4, C6, F7 F7 - -- -- -- . . • 1 I a ®' i • • .. .10 m7�.T.tT.Tfllllllli�['Lk• t1♦l�1'i__ :.�iTc'. > 1J• C7 •llGT7mmw i1GallIMiMINI ' MI . 1 1 IMIIMINIIIME7 1M c_ I<W]NSIIIIMM - - .. - . Iii 1 • . 1 1 . LWAMMINEtI I1M1M 1111M!!!MIErC=IIIIMIMC1• lSi7.liVAIN i • 1 �1:y7•y��iiilliZ!�i �Tc'��Tc =.fir IMEMIE 7�ETc1♦ . . .- .. ti • •. '' u . • ,10 = c,.. grammavalimmainummiwir E71111MiiMII r 'T: :4iiGIMINI 1rP. ME1011ii1Mi•ZI151111111111Tct♦■INVINIIIIIM■∎ic 1 1l : IIINi' •>i MIMMI 1 1 IIIMMIlMEifIMMIiiil l -- - Appproved Finishes Approved Temperature Ratings 1 - Brass, Bright Brass, and Chrome- Enloye 2 - Brass, Bright Brass, Chrome - Enloe White Polyester (White Poly finish for P/N 10139 only), A 135 °F (57 °C), 155 °F (68 °C), 175 °F and Black Polyester (Black Poly finish for P/N 10139 only) 3 - Brass, Bright Brass, Chrome-Enloe, White Polyester (White Poly finish for P/N 10139 only), and 3 79 °C 6, 200 °F 0 °F (182 °C)93 °C ) , 286 °F ( 141 °C), Black Polyester (Black Poly finish for P/N 10139 only), and Black Teflon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F 4 - Wax- Coated Brass and Wax over Polyester (Wax over Poly finish for P/N 10139 only). Corrosion (79 °C), and 200 °F (93 °C) resistant. • 5 - Wax- Coated Brass (corrosion resistant ' C - 286 °F (141 °C) ( resistant) D 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 6 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temper- °C , 200 °F 93 °C , and 212 °F 100 °C ature allowed at ceiling = 150 °F (65 °C) E - 135 °F (57 °C), 155 °F (68 °C)( 175 °F 7 - Brass and Chrome - Enloe® (79 °C), 200 °F (93 °C), 212 °F (100 °C), 8 - White Polyester (White Poly finish for P/N 10139 only), Black Polyester (Black Poly finish for P/N 286 °F (141 °C and 360 °F (182 °C) 10139 only), Black Teflon ,Wax Coated Brass, and Wax over Polyester (Wax over Poly finish F - 500 °F (260 °C)° for P/N 10139 only) 9 - Brass, Chrome -Enloe , White Poly finish, and Black Poly finish 1 n -Whitp Pnly finish_ Rlack Pnly finish, lnd Wax- Cnatpd Brass (nnrrnsinn resistant) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89 -92 -E, Vol. 12. ' UL and C -UL Listed as corrosion - resistant. - 5 Metric K- factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K- factor shown by 10.0. 6 Sprinklersof Ultra -High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra -High temperature rated sprinkler may be severely retarded. 7 FM Approval of Viking Micromatic Standard Response Recessed Pendent Sprinklers installed with the Viking Micromatic'• Model E -1 Recessed Escutch- eon is limited to wet systems and preaction systems qualifying as wet systems, for hazard occupancies up to and including Ordinary Hazard, Group II. 8 Listings and Approvals limited to Light - Hazard Occupancies with hydraulically calculated systems only. 9 Sprinkler I.D. Nos. and nominal U.S. K- factors provided in accordance with the 1999 edition of NFPA 13, Section 3 -2.2 and Section 3 -2.3. 10 Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered separately from sprinklers. Refer to Viking's current price schedule. NOTE: Spacing Requirements: Maximum Spacing: 15 ft. (4,57 m); Minimum Spacing: 6 ft. (1,8 m). Table 1 October 1, 2000 Sprinkler 11 c ®` • MICROMATIC AND TECHNICAL DAT MicromaticHP STANDARD • RESPONSE SPRINKLERS Approval Chart Temperature KEY MicromaticHP Standard Response Finish . Pendent Sprinklers A �— Maximum 250 PSI WWP Standard Orifice Thread Max. Nominal Overall Size Pressure Sprinkler Sprinkler Base Sprinkler K- Factor Length Listings and Approvals Style Part No. Identification No. NPT BSP PSIG U.S. metric Inch mm UL C -UL FM NYC VdS LPCB 1/2 15 250 Pendent 09992 VK122 5.6 7,9 2.3 58 Al Al -- -- -- -- Small Orifices • 1/2 15 250 Pendent 09994 VK023 2.8 3,9 2.7 69 Al Al -- -- -- -- -- 10 250 Pendent 10175 VK003 -- 5,8 2.3 58 Al -- -- -- -- -- Installed with the Viking Micromatic Model E -1 Recessed Escutcheon 1/2 15 250 Pendent 09992 VK122 5.6 7,9 2.3 58 B1 B1 -- -- -- -- 1/2 15 250 Pendent 09994$ VK023 2.8 3,9 2.7 69 B1 B1 -- -- -- -- - 10 250 Pendent 10175 VK003 -- 5,8 2.3 58 B1 -- _ -- -- -- -- Installed with the Viking Microfast® Model F -1 Adjustable Escutcheone' 1/2 15 250 Pendent 09992 VK122 5.6 7,9 2.3 58 Al Al -- -- -- -- 1/2 15 250 Pendent 09994$ VK023 2.8 3,9 2.7 69 • Al Al -- -- -- -- -- 10 250. Pendent 10175 VK003 -- 5,8 2.3 58 Al -- -- -- -- -- - Approved Temperature Ratings Approved Finishes A - 13 F (; 7 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F 1 - Brass, Bright Brass, Chrome-Enloe, White Polyester Na- F .. B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) vajo White Polyester Black Polyester and Black Teflon ®3 Footnotes • Base part number shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 UL and C -UL Listed as corrosion - resistant. 4 Metric K- factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K- factor shown by 10.0. 5 Listings and Approvals limited to Light- Hazard Occupancies with hydraulically calculated systems only. 6 The sprinkler orifice is bushed. 7 Sprinkler I.D. Nos. and nominal U.S. K- factors provided in accordance with the 1999 edition.of NFPA 13, Section 3 -2.2 and Section 3 -2.3. 6 The Microfast Adjustable Escutcheon is considered a surface - mounted escutcheon because it does not allow the fusible element of the sprin- kler to be recessed behind the face of the wall or ceiling. 9 Refer to the "Sprinkler Accessories" section for technical data on approved escutcheons and other accessories. Escutcheons must be ordered - separately from sprinklers. Refer to Viking's current price schedule. Table 2 I Mr • balm II 2-1 ICI 1 4 1' (25,4mm) (57,2mm) 1 -3/4" � _- Minimum (44,5mm) , f FE L LIJ-LIP = i 1 Viking 1/2" MicromaticHP® Pendent Viking 1/2" MicromaticHP Pendent Viking 1/2" MicromaticHP® Sprinkler Base Part No. 09992 installed with a Sprinkler Base Part No. 09992 installed Pendent Sprinkler Base Part standard 1/8" (3,1 mm) surface - mounted escutcheon. with the Viking Micromatic® Model E-1 No. 09992 Recessed Escutcheon. Figure 1 Sprinkler 11 d October 1, 2000 0: a . NIIIKING ® MICROMATIC AND TECHNICAL DATA ;` MicromaticHP STANDARD - - � RESPONSE SPRINKLERS Approval Chart Temperature KEY Micromatic and MicromaticHP® Standard Response Finish • Upright and Conventional Sprinklers Al Maximum 175 PSI WWP Standard Orifice Thread Max. Sprinkler Nominal Overall Size Pressure Sprinkler Base Sprinkler K- Factor Length Listings and Approvals 9 NPT BSP PSIG Style Part No.1 I.D. No.9 U.S. metrics Inch mm UL C -UL FM NYC VdS LPCB 1/2 -- 175 Upright 10138 VK100 5.6 -- 2.3 58 A3, B4, C6, F7A3, B4, C6, F7 A7, D5, F7 A3 B4, C6 " "" 1/2 -- 175 Upright 10233 VK100 5.6 -- 2.3 58 -- -- A7, D5, F7 -- A2 Al, B8 -- 15 175 Upright 10174 VK100 -- 7,9 2.3 58 -- -- A7, D5, El -- A2 Al, B8 -- 15 175 Upright 10193 VK100 -- 7,9 2.3 58 A3, B4, C6, F7A3, B4, C6, F7 A7, D5, El A3, B4, Large Orifice 1/2 -- 175 Upright 10220 VK200 8.0 -- 2.4 61 A3, B4, C6, F7A3, 84, C6, F7 A7, D5, F7 A3, B4 -- -- . 3/4 -- 175 Upright 10141 VK200 8.0 11,5 2.4 61 A3, B4, C6, F7A3, B4, C6, F7 A7, D5, F7 A C64' A2 Al, B8 -- 15 175 Upright 10190 VK200 -- 11,5 2.4 61 A3, B4, C6, F7A3, B4, C6, F7 D5 -- -- Al, 88 -- 20 175 Upright 10169 VK200 -- 11,5 2.4 61 A3, B4, C6 A3, B4, C6 D5, El -- A2 Al, B8 • Small Orifice 1/2 -- 175 Upright 10191 VK002 4.2 -- 2.3 58 A3, B4, C6, F7A3, B4, C6, F7 -- 1/2 -- 175 Upright 10218 VK001 2.8 -- 2.3 58 A3, 84, C6, F7A3, B4, C6, F7 87, B5 A3, B4 -- 1/2 -- 175 Upright 10219 • VK002 4.2 -- 2.3 58 A3, B4, C6, F7A3, B4, C6, F7 -- A3, 84 -- -- 10 175 Upright 10176 VK001 -- 5,8 2.3 58 -- -- -- _- A2 A1, 88 -- 15 175 Upright 10192 VK001 _ 2.8 -- 2.3 58 A3, 84, C6, F7A3, 84, C6, F7 E5 -- -- -- Conventional ;' 1/2 -- 175 Corm 10227 VK118 5.6 -- 2.3 58 A3, 84, C6 A3, B4, C6 -- A2 Al, B1C ` ' 3/4 -- 175 Cony. 10228 VK120 8.0 -- 2.4 61 A3, B4, C6 A3, B4, C6 -- -- A2 Al, B10 -- 15 175 Cony. 10172 VK118 -- 7,9 2.3 58 A3, B4, C6 A3, B4, C6 -- -- A2 A1, B1C -- 20 175 Conv. 10168 VK120 -- 11,5 2.4 61 A3, B4, C6 A3, B4, C6 -- -- A2 Al, B10 Maximum 250 PSI WWP Standard Orifice 1/2 15 250 Upright 09993 VK124 5.6 7,9 2.3 58 G9 G9 I -- SmallOrificee _ 1/2 15 250 Upright 09995 VK021 2.8 3,9 2.7 69 G9 G9 -- - -- 10 250 Upright 10176 VK001 -- 5,8 2.3 58 G9 • -- -- __ -_ Approved Temperature Ratings Approved Finishes 1 - Brass, Bright Brass, and Chrome- Enloy® A 135 °F (57 °C), 155 °F (68 °C),175 °F (79 °C), 200 °F (93 2 - Brass, Bright Brass, Chrome- Enloy® White Polyester, and Black Polyester °C), 286 °F (141 °C), and 360 °F (182 °C) 3 Brass, B ® Brass, Chrome-Enloe: White Polyester, Black Polyesters, and B- 135 °F (57 °C) 155 °F (68 °C), 175 °F (79 °C), and Black Teflon 200 °F (93 °C) 4 - Wax Black Brass and Wax over Polyester (corrosion resistant) C - 286 °F (( °C) 5 - Wax - Coated Brass (corrosion resistant) D -135 °F {57 °C °, 155 °F (68 °C), 175 °F (79 °C), 200 °F(93 6 - 200 °F (93 °C) High- Temperature Wax Coating (corrosion resistant); maximum ° and 2° 2 1 5 °F (C) ambient temperature allowed at ceiling = 150 °F (65 °C) E - °C) °F ( 57 ) , (1 °F ( 68 °C ) , 175 °F 79 °C , 200 °F (93 7 - Brass and Chrome- Enloy® ( ) ( 8 - White Polyester, Black Polyester, Black Teflon ®, Wax- Coated Brass, and Wax °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C) over Polyester F - 500 °F (260 °C)6 9 - Brass, Bright Brass, Chrome- Enloy®, White Polyester, Navajo White Polyes- G -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 ter, Black Polyester, and Black Teflon °C), and 286 °F (141 °C) 10 -White Polyester, Black Polyester, and Wax- Coated Brass Footnotes 1 Base part number shown. For complete part:number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 3 Accepted for use, City of New York Department of Buildings, MEA Number 89 -92 -E, Vol. 12. 4 UL and C -UL Listed as corrosion - resistant. 5 Metric K- factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K- factor shown by 10.0. 6 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra -High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of. the Ultra -High temperature rated sprinkler may be severely retarded. 7 Listings and Approvals limited to Light- Hazard Occupancies with hydraulically calculated systems only. • - 8 The sprinkler orifice is bushed. 9 Sprinkler I.D. Nos. and nominal U.S. K- factors provided in accordance with the 1999 edition of NFPA 13, Section 3 -2.2 and Section 3 -2.3. 10 Spacing Requirements: Maximum Spacing: 15 ft. (4,57 m); Minimum Spacing: 6 ft. (1,8 m) Table 3 New format replaces page 11 a -d, dated -May 18, 2000 and page 31 Form No. F100397 a -d, dated May 27, 1999. Refer to technical data page SR1 -2 for - general care, installation, and maintenance information. October 1, 2000 7S?0 54") j4 ry z. jt r Kc( Sprinkler 102 a '' 0 ;` .;. STANDARD RESPONSE �; TECHNICAL DATA . DRY HORIZONTAL . - SIDEWALL SPRINKLERS 1. PRODUCT NAME Viking Model M Standard Response Dry 4. Horizontal Sidewall Sprinklers � z i - =_. Adjustable - • Adjustable Recessed , �1 ' • Adjustable Standard _ Recessed • Plain Barrel h' y .. 2. MANUFACTURER - ,j The Viking Corporation 210 N. Industrial Park Road ,-..'! �x Hastings, Michigan 49058, USA ,. ,.m ` f7 1:,..:„::., Adjustable • Telephone: (616) 945-9501 ,�;,,, " ° . ` '• i� Standard (877) 384 -5464 ,, �j -f -, Fax: (616) 945 -9599 ;' e -mail: techsvcs @vikingcorp.com 3. PRODUCT DESCRIPTION The Viking Standard Response Dry Sidewall Sprinkler is a thermosensitive „ y� .4 Plain glass -bulb spray sprinkler, suitable for -' Barrel use in areas subject to freezing. It is designed for dry systems and preaction For Light- Hazard Occupancies only. systems where it is necessary to prevent water or condensation from entering the Both escutcheon styles slide over the sprin- Minimum operating pressure: 7 psi • supply nipple before the sprinkler oper- kler deflector, allowing installation of the es- (48,3 kPa) ates. It may also be installed in spaces cutcheon after the wall finish is applied. K- Factor: 5.6 U.S.t (7,9 metric ") for all subject to freezing and supplied from a These sprinklers may be ordered in min- listed and approved lengths. • wet system in an adjacent heated area. imum lengths from 1-1/2" (38,1 mm) for t Nominal U.S. K- factor provided in accordance The assembly features a sealed brass inlet Sprinkler Base Part Numbers 07857 and with the 1999 edition of NFPA 13, Section 3 -2.3. "Metric K- factor shown is for use when pressure and a durable, threaded steel barrel with an 07860, and 3” (76,2 mm) for Sprinkler is measured in kPa. When pressure in BAR, • • 1) electrodeposited epoxy base coating. The Base Part Numbers 07856, 07859, multiply K- factor shown by 10.0. sprinkler is of the Model M design with a 07858, and 07861. They are available Factory tested pneumatically at 100 psi rugged 5 mm glass bulb and horizontal with a maximum length of 48" (1 219,2 (685 kPa). sidewall deflector. The Viking Standard Re- mm) °. They are available in 1/4" (6,35 Spring: U.S.A. Patent No. 4,167,974 sponse Dry Horizontal Sidewall Sprinkler is mm) increments for the recessed style, Deflector: U.S.A. Patent No. 4,296,816 available in several finishes and tempera- and in 1/2" increments for the adjustable Bulb: U.S.A. Patent No. 4,796,710 - ture ratings to meet design requirements. standard escutcheon style, and the plain SPRINKLER MATERIALS The seal at the threaded end of the as- barrel style, installed with no escutcheon. Frame: Brass Castings UNS-C84400 sembly is held in place by force transmit- 4. TECHNICAL DATA Deflector: Copper UNS- C19500 ted from the compression screw, through LISTINGS AND APPROVALS Bulb: Glass, nominal 5 mm diameter • the glass bulb and internal parts, onto a Refer to Table 1 on page 102 d. Seal: Teflon® Tape . special sealing spring. During fire condi- Approved to maximum length of 48" • Spring: Nickel Alloy tions, the heat - sensitive liquid in the glass . (1 219,2 mm) *. Screw: Brass UNS- C36000 bulb expands, causing the glass to shat- • Lengths between 48" and 60" (1 219,2 mm and 1 524 Pip Cap: Brass UNS- C31600 ter, releasing the internal parts to open the mm) are available, with no approvals, on a"made- Seat: Copper UNS- C21000 to- order" basis. Contact the manufacturer. waterway. Water flowing through the Orifice: Copper UNS- C21000 Glass -bulb fluid temperature Washer: Stainless Steel UNS-S30400 rated to sprinkler orifice strikes the sprinkler de- -65 °F ( -55 ° C). flector, forming a uniform spray pattern to Rated to 175 psi (1 207 kPa) water work- Base: Brass UNS- C31400 extinguish or control the fire. Gasket: Buna N The Viking Standard Response Dry ing pressure. Pin: Stainless Steel UNS- S42000 Thread Size: 1" NPT or 25 mm BSP Horizontal Sidewall Sprinkler may be in- Tube: JIC Hydraulic Steel Tube Orifice Size: Standard Orifice stalled with the barrel exposed (refer to Inlet: Brass UNS- C36000 Figure 4 on page 102 d), or with one of two escutcheon styles: Sprinkler Nominal Sprinkle Ceiling Temperature at Sprinkler —1 1 • For recessed installations, a recessed Temperature Temp. Rating Max. Ambient Max. Recommended Bulb I Colo style escutcheon with up to 5/8" (15,8 Classification) (Fusing Point) Temp. Allowed Ambient Temp,2 Colon Coding mm) adjustment (see Figure 1 on page Ordinary 135 °F (57 °C) 115 °F (46 °C) 100 °F (38 °C) Oran .e None 102 b), is available. _ Ordinary 155 °F (68 °C) 1 135 °F (57 °CL 100 °FJ38 °C) Red None • For standard installations, the sprinkler Intermediate 175 °F (79 °C) 155 °F (_68_ °C) 150 °F (65 °C) Yellow White is available with an adjustable, sur- . Intermediate 200 °F (93 °C) 180 °F (82 °C) 150 °F (65 °C) Green White face- mounted escutcheon, finished to High . 286 °F (141 °C)_ 266 °F (130 °C) 225 °F (iQ7 °C) I Blue Blue ,..) allow up to 2" (50,8 mm) of adjustment Footnotes !! (see Figures 2 and 3 on page 102 c). 1 Based on National Fire Prevention and Control Administration Contract No. 7- 34860. ✓ 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Frames of decorative sprinklers are not color coded. Temp. rating is stamped on the deflector. Note: Units of measure in parentheses may be approximations. Replaces sprinkler page 102 a -e, dated May 14, 1998 Form No. F_073091 073091 (added Sprinkler Identification Numbers.) • f Sprinkler 102 b October 1, 2000 NI ..._.... .„ , NG ... `` STANDARD RESPONSE "'TECHN D ATA DRY HORIZONTAL SIDEWALL SPRINKLERS Support (Internal): Steel UNS- G10080 For "A" Dimension: . Electrodeposited Epoxy Base finish 1. Determine the distance from face of tee to face Barrel: Steel Pipe UNS- G10200 of finished wall. 11111111111111111E- . Electrodeposited Epoxy Base finish 2. Round to nearest 1/4" (6,35 mm) between 3 -1/4" L Ceiling ACCESSORIES and 48" (82,5 mm and 1 219,2 mm). Standard Dry Sprinkler Wrench: Part NOTE: The sprinkler will be recessed approximately Wall • No. 07297W/B 5/16" (7,9 mm) with 5/8" (15,8 mm) horizontal 4" (102 mm) Minimum AVAILABLE FINISHES adjustment A 6" (152 mm) Maximum • Recessed: Chrome - Enloy® (patents available. I pending) or White Polyester • Standard Adjustable: Chrome- Enloyo Fri • Plain Barrel: Chrome- Enloy® or Brass E -W � - 1 / 2 " (12,7 mm) (sprinkler only) • � ORDERING INFORMATION `• i 1 3 - 1/16" For proper shipment, specify model, fin- 1 1 MN _ ; (77,8 mm) ish, temperature rating, escutcheon type, . and length ( "A" Dimension. Dry Minimum ceiling hole size: , horizontal sidewall sprinklers are or- 2 -1/8" (54 mm) diameter. I I dered in specific lengths noted as the Maximum ceiling hole size: W" Available "A" dimension (see Figures 1 through 4). 2 -1/2" (63,5 mm) diameter. Adjustment The "A" dimension is the distance from 1 -7/8" (47,6 mm) Minimum the face of the fitting (tee) to the finished 2 -1/2" (63,5 mm) Maximum surface of the wall in which it is to be in- 5/16" (7,9 mm) Outward Adjustment stalled. The dry horizontal sidewall 5/16" (7,9 mm) Inward Adjustment sprinkler must be ordered and c Figure 1: Adjustable Recessed Dry Horizontal Sidewall Sprinkler lured specifically for one of three ee styles of installation: with the adjustable re- cessed escutcheon (see Figure 1), with modification, may render the sprinkler perature allowed. Such sprinklers the adjustable standard escutcheon (see inoperative and will automatically nullify should be destroyed immediately. the approval and an Figures 2 and 3), or with the plain barrel pP any guarantee made C. Viking Standard Response Dry Hori (see Figure 4). For limits of adjustment for by The Viking Corporation. zontal Sidewall Sprinklers are not in- the recessed escutcheon, see Figure 1. A. Sprinklers are to be installed in accor- tended for use in corrosive environ- Details and limits of adjustment for the dance with the latest published stan- ments. Use only sprinklers listed for standard escutcheon style, with 2" (50,8 dards of the National Fire Protection 'corrosive environments when sub - mm) ofadjustment, are shown in Figure 2. Association, Factory Mutual, Loss ject to corrosive atmospheres. • 5. AVAILABILITY AND SERVICE Prevention Council, Assemblee WARNING: Standard Response Dry Viking products are available through a Pleniere, Verband der Sachver- Horizontal Sidewall Sprinklers network of domestic, Canadian, and in- sicherer or other similar organizations, ' MUST be installed into the 1" outlet ternational distributors. See the Yellow and also with provisions of govern- of a cast iron or malleable iron tee fit - mental codes, ordinances, and stan- ting only. The threaded end of the dry Pages of the telephone directory for a lo- dards whenever applicable. The use cal distributor (listed under of a cast iron or malleable ir • or contact The of dry horizontal sidewall sprinklers the seal to penetrate and extend into • may be limited due to occupancy and the fitting to a predetermined depth. Viking Corporation. hazard. Refer to the Authority Having , 1. DO NOT install the dry sidewall . Viking Technical Data may be found on Jurisdiction prior to installation. sprinkler into a threaded elbow, The Viking Corporation's Web site at B. Sprinklers must be handled with care. coupling, or any other fitting that http: / /www.vikingcorp.com. They must be stored in a cool,, dry could interfere with thread penetra- • The Web site may include a more recent place in their original container. lion. Such installation will dam • edition of this Technical Data page. Never install sprinklers that have age the brass seal. 2. DO NOT install the dry sidewall sprin- been dropped or damaged in any 6. GUARANTEES kler into a coupling or fitting that will way. Never install any glass -bulb allow condensation to accumulate For details of warranty, refer to Viking's sprinkler if the bulb is cracked or if above the seal, when located in an current list price schedule or contact there is a loss of liquid from the bulb. If area subject to freezing. The Viking Corporation directly. a glass bulb lacks the appropriate 3. NEVER try to modify the dry horizon - 7. INSTALLATION amount of fluid, it should be set aside tal sidewall sprinkler. The sprinklers WARNING: Viking sprinklers are manu- and returned to Viking (or an autho- are manufactured for specific "A" di- I factured and tested to meet the rigid re- rized Viking distributor) for analysis as mensions and cannot be modified. quirements of approving agencies. The soon as possible. If the sprinkler is not D. The sprinkler must be installed after sprinklers are designed to be installed in returned to Viking, it should be de the piping is in place to prevent me accordance with recognized installation stroyed. Never install sprinklers that chanical damage. • standards. Deviation from the standards have been exposed to temperatures in 1. Before installing the sprinkler, make alteration to the sprinkler after it certain the "A" dimension is correct or any P excess of the maximum ambient tern- and the sprinkler is the appropriate leaves the factory including, but not lim- ited to: painting, plating, coating, or • October 1, 2000 Sprinkler 102 c KING 0 STANDARD RESPONSE , . TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS For "A" Dimension: 1. Determine the distance from face of tee to fin- " " " " " " " " "....., NOTE: ished face of wall. muuuuuuuuummuuumullue ` To locate deflector 2. Round to nearest 1/2" (12,7 mm) between Finished Ceiling at minimum distance 1 -1/2" and 48" (38,1 mm and 1 219,2 mm). �_ from wall, with no NOTE: Deflector will extend approximately Finished Wall N adjustment available, 4 -1/4" (108 mm) from wall with 2" [ +/- 1" (25,4 4" (.102 mm) Minimum order the standard mm)] of horizontal _ A 6" (152 mm) Maximum I 3 -1/4', dry horizontal side- • adjustment available. (82,6 mm, wall sprinkler 1" (25,4 mm) shorter than Deflector at Minimum "A" dimension. , � Distance from Wall 147111111 I odor 3 1 /1611 — - 77,8 mm) "" NOTE: 1/2" ( 1 2 1 7 mm) To Minimum wall opening maximu m deflector distance at diameter: 1 -3l4" (44,45 mm). L from wall, with no Maximum wall opening L Sleeve diameter: adjustment available, diameter: 2 -1/4" (57 mm). • 13/16" 1 -1/2" (38,1 mm). MN I, order the standard (20,6 mm) Sleeve finish matches p dry horizontal side - finish of escutcheon. 5-1/4" wall sprinkler 1" (133,4 mm) (25,4 mm) longer Figure 2 Deflector at Maximum than "A" dimension. Adjustable Standard Dry Horizontal Sidewall Sprinkler Distance from Wall ^ 11 1111111 llllllllllll 111111111 lllllll 1111116 111111111111111111 11111111111111111111111. 1111111111111111111111 1111111111111111111 11111111111111111111111111111111111111111E Slot -, Deflector — — Push and rotate Slot � l �.! I ��� I�i % - __ - _ iii 111 I- I �� Sleeve I I op% I ll STEP 1: Align slot in escutch- STEP 2: Push rounded end STEP 3: Pull escutch- STEP 4: Push and ro- STEP 5: To minimize eon with the horizontal sur- of slot against the near eon away from the near tate the escutcheon visibility of the slot in the face of deflector as shown, edge of deflector. Push far edge of deflector. Move onto the sleeve. escutcheon, position the side of escutcheon past the near side of escutcheon slot at top of sprinkler deflector, toward the over deflector. sleeve. sleeve. Figure 3 Adjustable Standard Escutcheon Installation model and style, with the proper on- kler installation to ensure that no tion. For minimum maintenance and in- fice size and temperature rating. damage has occurred to the sprinkler spection requirements, refer to the Na- 2. Apply a small amount of pipe -joint during shipment and installation, and tional Fire Protection Association's compound or tape to the male to make certain the unit has been pamphlet that describes care and main - threads only, taking care not to al tenance of s nnkler s low a build -up of compound over the properly tightened. If a thread leak p ystems. In addi brass inlet and seal. occurs, normally the unit must be re- tion, the Authority Having Jurisdiction • 3. Install the dry sidewall sprinkler on the moved, new pipe- joint compound or may have additional maintenance, test - piping using the special dry sprinkler tape applied, and then reinstalled. ing, and inspection requirements that wrench only, while taking care not to This is due to the fact that when the must be followed. damage the sprinkler. DO NOT use a joint seal leaks, the sealing corn- A. The sprinklers must be inspected on pipe wrench on the barrel of the dry pound is washed out of the joint. a regular basis for signs of corrosion, sidewall sprinkler. A pipe wrench F. Wet pipe systems supplying dry hori- mechanical damage, obstructions, may damage the barrel finish. zontal sidewall sprinklers must be paint, etc. The frequency of inspec- 4. To install the escutcheon for the adjust - able standard style dry horizontal side- provided with adequate heat. Refer tions may vary due to corrosive at- wall sprinkler, refer to Figure 3. to appropriate installation standards. mospheres, water supplies, and ac- E. After installation, the entire sprinkler $. MAINTENANCE tivity around the device. system must be tested in accordance NOTICE: The owner is responsible for B.S prinklers that have been field with recognized installation stan- maintaining the fire - protection system painted, caulked, or mechanically dards. The test is applied after sprin- and devices in proper operating condi- damaged must be replaced immedi- • Sprinkler 102 d October 1, 2000 . ® C = "° " ' . STANDARD RESPONSE i °TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS ately. Sprinklers showing signs of have operated cannot be reassem- service. Refer to the appropriate sys- corrosion shall be tested and /or re- bled or re -used, but must be re- tern description and /or valve instruc- placed immediately as required. In- placed. When replacing sprinklers, tions. Prior to removing the system stallation standards require sprin- use only new sprinklers. from service, notify all Authorities klers to be tested and, if necessary, C. The sprinkler discharge pattern is criti- Having Jurisdiction. Consideration replaced after a specified term of ser- cal for proper fire protection. Nothing should be given to employment of a • vice. Refer to the installation stan- should be hung from, attached to, or fire patrol in the effected area. dards and the Authority Having Juris- otherwise obstruct the discharge pat- 1. Remove the system from service, diction for the specified period of time tern. All obstructions must be immedi- drain all water, and relieve all pres- after which testing and /or replace- ately removed or, if necessary, addi- sure on the piping. ment is required. Never attempt to re- tional sprinklers installed. 2. Using the special dry sprinkler pair or reassemble a dry horizontal D. When replacing existing sprinklers, wrench, remove the old sprinkler sidewall sprinkler. Sprinklers that the system must be removed from and install the new unit. Care must be taken to ensure that the replace - ment sprinkler is the proper model For "A" Dimension: and style, with the appropriate "A" 1. Determine the distance from the face of tee to IOhIIIIIIIIIUI dimension, orifice size, and temper - the base of sprinkler. ature rating. 2. Round to next higher 1/2" (12,7 mm) increment Ceiling 3. Place the system back in service and between 3" and 48" (76,2 mm and 1 219,2 mm). Wall secure all valves. Check for and re - 4" (102 mm) Minimum p air all leaks. 6" (152 mm) Maximum E. Sprinkler systems that have been 2 7/16" f A subjected to fire must be returned to • (61,9 mmj service as soon as possible. The en- tire system must be inspected for _ _ ___ _ _ _ _ _ _ 1/2" ( 12,7 mm) damage, and repaired or replaced as r _ � �i necessary. Sprinklers that have I been exposed to corrosive products Outside diameter: 1 - 5/16 "_ - L of combustion or high ambient tern- (33,4 mm). [Same as 1" L peratures, but have not operated, o-,`- -. — V — Do not exceed 6" (152 mm). (25 mm) Schedule 40 pipe). should be replaced. Refer to the Au Do not recess wrench boss. thority Having Jurisdiction for mini - Figure 4 mum replacement requirements. Plain Barrel Dry Horizontal Sidewall Sprinkler . • 1 Temperature KEY Approval Chart Finish ' Standard Response Dry Horizontal Sidewall Sprinklers • Al X a — Escutcheon (if applicable) Thread Size Sprinkler Description Nominal K-factor Overall Length Increment Listings and Approvals Sprinkler Sprinkler NPT BSP Sprinkler Style Base Part Identification U.S. metric Inches mm UL ULC FM NYCS No. No. 1 Adjustable Standard 07857 VK156 5.6 7,9 1/2" 12.7 Al Al Al Al — 25 mm 07860 VK156 5.6 7,9 1/2" 12,7 Al Al Al Al l Adjustable Recessed 07856 VK162 5. 7.9 1/4" 6,35 B2 B2 — B2 — 25 mm 07859 VK162 5. 6 7,9 1/4" 6,35 B2 B2 — B2 1" — Plain Barrel 07858 VK152 5.6 7,9 1/2" 12,7 A3 A3 A3 A3 — 25 mm 07861 VK152 5.6 7.9 1/2" 12.7 A3 I A3 - A3 A3 Approved Temperature Ratings Available Approved Finishes and "A" Dimensions 1 - Chrome -Enlo ® with "A" dimensions 1 -1/2" to 48" (38,1 mm to 1 219 mm) A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) 2 Chrome Enbor White with "A" dimensions 3-1/4" to 48" (82,5 mm to 1 219 mm) B -135 °F (57 ° C). 155 °F (68 °C). 175 °F (79 °C). and 200 °F (93 °C) 3 - Chrome- Enloy®or Brass with "A" dimensions 3" to 48" (76,2 mm to l 219 mm) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. NOTE: Viking Standard Response Dry Horizontal Sidewall Sprinklers are listed for installation in Light- Hazard occupancies. Viking Standard Re- sponse Dry Horizontal Sidewall Sprinklers must be positioned between 4" and 6" (102 mm and 152 mm) below smooth ceilings, and not less than 4" (102 mm) from walls otherthan the wall in which they are installed. Top of deflector must be aligned parallel with the ceiling. Refer to appro- priate Installation Guide. 3 Minimum length ( "A" Dimension) = 1 -1/2" (38,1 mm) for Sprinkler Base P /Ns 07857 and 07860, and 3" (76,2 mm) for Sprinkler Base P /Ns 07856, 07859, 07858, and 07861. Maximum standard (listed and approved) length ( "A" Dimension) = 48" (1 219,2 mm). 4 K- factor applies for all lengths indicated in Footnote 3. Metric K- Factor shown is for use when pressure is measured in kPa. When pressure is mea- sured in BAR, multiply the metric K- Factor shown by 10.0. 5 Accepted for use, City of New York Department of Buildings, MEA 89 -92 -E, Vol. II. 6 Sprinkler I.D. Nos. and nominal U.S. K- factors provided in accordance with the 1999 edition of NFPA 13, Section 3 -2.2 and Section 3 -2.3. Table 1 . Replaces sprinkler page 102 a -e, dated May 14, 1998 Form No. F073091 (added Sprinkler Identification Numbers.) -