Loading...
Specifications INTELLIKNIGHT MODEL 5808 FIRE ALARM CONTROL PANEL. Inteliiknight® Model 5808 ' � : Single Loop Addressable f� , a .� Fire Alarm Control System ' The convenience of an addressable fire "� 7 '' alarm control panel in a cost effective '4 easy to use package. Zi '.1 3 ': . _ IntelliKnight Model 5808 is a 127 point class leading single loop ' • addressable fire alarm control /communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763 -493 -6435. Description • Built -in RS -232 interface for The IntelliKnight 5808 performs drift programming via PC. _ , compensation and calibration checks • Built -in Form C trouble relay rated at b on each of the sensors in the system. 2.5 amps at 24 VDC. i• The basic IntelliKnight 5808 system • Two built -in Form C programmable _ amps at 24 VDC. rn relays rated at 2.5 am " -- can be enhanced by adding modules Y P such as the Model 5860 Remote Approvals: Annunciator, the Model 5824 UL Listed / NFPA 72 Serial /Parallel Interface (for printing - Central Station system reports), and an Intelligent -DACT Power Module. The Model 5808 also -Local Protective features a powerful built -in dual line fire Signalling System k - communicator that allows for reporting -Water Deluge of all system activity to a remote l monitoring location. Releasing Service J Features Specifications • Up to 127 addressable points. Primary AC: 120 VRMS at 50 / 60 hz, • Uses standard wire —no shielded or 2.75A Total Accessory Load: 6A at 24 VDC twisted pair required. «; „ • Built -in digital communicator. 6 amps at 24 VDC of power - limited notification power , ,nhueKWigM• • Central station reporting by Point or P by Zone. Standby Current: 206 mA • Supports Class B (Style 4) and Class Alarm Current: 356 mA Model 5808 A (Style 6) configuration for SLC. Notification circuits: 3 amps of Telephone Requirements: • Distributed, intelligent power. power - limited power per circuit at 24 FCC Part 15 and Part 68 approved • Drift compensation. VDC. • 13 re ro rammed output Type of Jack: RJ31X (two required) P P g P Auxiliary power circuits: 3 amps of cadences, (including ANSI - 3.41), and power - limited power per circuit at 24 4 programmable outputs. VDC. • Notification circuits can be configured Mechanical Specifications: 071 as 2 Class A (Style Z) or 4 Class B ��� — (Style Y), or auxiliary power for Flush Mount resettable, constant, or door holder Dimensions / / G, 6 5 --i-() ?Val RA power. 14.5 "W x 24.75 "H x 3.5 "D • Built -in annunciator with 80- character (36.8W x 62.9H x 8.73D cm) LCD display. Overall • RS -485 bus provides communication Dimensions: to system accessories. 16 "W x 26.4 "H x 4.65 "D SILENT • Up or Down load programming, (40.6 x 67 x 11.8 cm) KNIGI IT event history, or detector status via Weight: 28 lbs. (12.8 kg) remote or direct connection. Color: Red INTELLIKNIGHT FIRE ALARM CONTROL PANEL fi, SLC Sensor Devices Intelligent SLC Modules 5496 Intelligent Power Module Model SD505 -APS Model SD500 -AIM The Model 5496 is a 6 amp.notification power Addressable photoelectric smoke detector. Dry Contact Input Module. Designed to used expander that provides Model SD505 -AIS with normally open dry contacts. Mounts in a four additional power - Addressable ionization smoke detector. 4 inch square electrical box. It features an limited notification indicator LED to show alarm status and a appliance circuit outputs. Model SD505 -AHS coverplate. 5865 -3 and 5865 -4 ., ,_.;: Addressable heat sensor. Model SD500 -MIM Model SD505 -6AB Mini Dry Contact Input Module. A miniature Remote LED Six inch base designed for use with detector version of the addressable input module Annunciator head models SD505 -APS, SD505 -AIS and which is designed to be used with pull Features 30 Programmable LEDs (15 red SD505 -AHS. stations and other normally open dry contact and 15 yellow) outputs and piezo sounder. Model SD505 -ADH inputs where a smaller size is desired. The 5865-4 adds a silence and reset switch ARM to the package. SD500-ARM Housing. Detects smoke in HVAC Mod 5883 Relay Board ducts. Use with SD505 -APS or SD505 -AIS. Addressable Relay Module. Features 2 SD505- ADHR/DTS Form C output relays, designed to mount on Features 10 General purpose Form C a 4 inch square electrical box. Provides relays. Used with 5880 module. Addressable Duct smoke detector with built- indicator LED to show output status and 5824 Serial /Parallel Gateway in relay module detects products of comes with a coverplate, combustion present in air moving through an Module HVAC system. Provides form C alarm Model SD500 -LED Has one parallel and one RS -232 serial port contact. The SD505 -ADHR is compatible An LED driver capable of driving 80 LEDs for connecting any standard IBM - compatible with the SD505 -DTS, which provides remote through the SLC loop. Up to 40 SD500- printer to the IntelliKnight system. Interfaces annunciation and testing capabilities for the LEDs can be used per system. with building control system. SD505 -ADHR. Use with SD505 -APS or S -BUS Accessories SKSS Silent Knight Software SD505 -AIS. The following items listed are devices that Suite Model SD500 -PS connected to the IntelliKnight's RS-485 Bus Addressable Pull Station with visible LED. 5860 Remote Fire Annunciator 5660 Up Down Load Software The 5860 features the same 80 character User - friendly, WindowsTM software for backlit LCD display keypad and firefighter's remote programming of the IntelliKnight keyswitch as the 5820. The system can be panel using a PC. fully programmed and operated from any 5670 Facility Management remote annunciator. Software 5880 LED/I0 Module Powerful end -user software allows viewing Features 40 LED outputs, 8 normally open of detector status and event history via dry contact inputs and one piezo output. modem or direct connection. I r ego 9 K64 . . .. .r 69160 iR4 - 6 Mcw S06Na.61 s I 110110400 IICI 14 AP$ WS/15411 O OMAN I i � Y , I a 14 1618tRNer NYC5 .r.95mM... t 1-- 110141114131111 109004% IMAM 10111k R91 +srs.w.see w.axa.w +.uewiat '7=s. e m f...sa � "o+ .iG w.sov� ecoa�.e, '. sawa+aw r,an. 4 .. *-1111111114 wt 64.1* . i t SILENT KNIG 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 763 -493 -6435 FORM# 350386, Rev. 9/01 FAX: 763 -493 -6475 World Wide Web: http: / /www.silentknight.com Copyright © 2001 Silent Knight INTELLIKNIGHT ACCESSORY Model 5860 001 t , v 1 Remote Annunciator ; ;;',#1 Bring the power to control IntelliKnight® to every area within your facility. Now you can operate and program your IntelliKnight system from up to 8 locations throughout your facility. The Model 5860 Remote Annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Wire runs can be up to 6000 feet from the panel. Model 5860 Users identify themselves to the control panel by entering a code on Remote Annunciator the annunciator or by turning the The 5860 is designed to look and 9 firefighter's key. When a user �. operate exactly the same as the presses a button, the annunciator IntelliKnight built -in annunciator. piezo beeps and the LCD prompts Features include an 80- character the user to enter a code or other backlit LCD providing easy -to- relevant information. p... understand system messages. The annunciator is ergonomically Multiple users can work at different 5860 Remote Annunciator designed with over -sized buttons annunciators simultaneously for the most frequently used without affecting each other. Specifications Operating Voltage: 24 VDC features, like Reset and Silence. Features Standby Current: 20 mA In addition to status messages • 80- character display displayed on the LCD, there are Alarm Current: 25 mA • Tactile /audible feedback five LEDs for alarm, supervisory, Max. per system: 8 • trouble, silence, and AC power Accepts user codes or status. firefighter's key Ambient Temperature: 32°F to 120°F (0°C to 49°C) • RS -485 interface to panel The annunciator is available in gray Mounting: Surface or flush • to match virtually any decor and red Can be flush- or surface - for applications where the mounted. Trim ring available for Wiring Distance from PP IntelliKnight panel: Up to 6,000 feet annunciator must stand out. The surface mounting. annunciator enclosure can be • Operation and appearance Dimensions: Height: 7 -3/8" identical to on -board annunciator Width: 9-1/8" 1 surface or flush mounted. A trim Depth: 1-1/2" ring kit is available for surface • Supports simultaneous use by Colors: Lt. gray (5860) mounting. multiple users Red (5860R) Operation • UL listed, complies with NFPA 72 • When the system is normal and CSFM Approved receiving AC power, the power LED • MEA Listed is lit and all other LEDs are off. Other LEDs turn on as the it SILENT conditions occur. KNIGHT INTELLIKNIGHT ACCESSORY • Mode! 5860 Remote Annunciator i Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. 5860 Block Diagram 4'4` fact item panel I : 1 SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 -6444 or in Minnesota 612 - 493 -6435 FORM# 350224, Rev. 01/00 FAX: 612 -493 -6475 Copyright ©2000 Silent Knight World Wide Web: http: / /www.silentknight.com FIRE ALARM INITIATING DEVICES ill D Cast Metal of , Manual Pull Stations 3 ,. :,„ ,,, } 7 r f Vii .., Silent Knight die cast metal manual h pull stations put quality and peace g ' ; of mind in easy reach. A manual pull station doesn't have to be fancy — just tough, reliable and extremely easy to operate. Silent Knight's die cast metal pull stations are all three. They're the high - quality choice for fast, sure initiation of a fire alarm signal. Our manual pull stations feature rugged, die cast metal construction that lasts and lasts. They're available in single or dual action models. And Silent Knight manual pull stations are UL- Listed, CSFM Approved, and MEA (BSA) Approved. For outdoor use, a weatherproof model is also available. On your next job, make the high - quality choice – Silent Knight manual pull stations. For more information, or for additional information on our complete fire products line, call Silent Knight today at 1- 800 - 446 -6444, or in Minnesota call (612) 493 -6435. Die Cast Metal Manual Operation Stations The single action pull stations are Silent Knight's new line of manual pull operated by simply pulling the handle on :< stations feature high - quality, die cast the front of the station as far down as it metal construction. They are available in will go, at which point the handle locks � - w - i either single or dual action configurations into place and is easily visible from up to I PULL with SPST switch, and with wire lead or 50 feet. A scored acrylic break rod is also terminal strip connections. The normally supplied with each unit for applications , ` , open contact, which closes when the pull where that is necessary. The handle is - ' .. station is activated, is rated for 1 amp, at reset by opening the station with the hex 125VAC, or 30VDC. The contacts are wrench or key, placing the handle in gold - plated to avoid risk of corrosion. All the normal upright position and relocking models in the series have been tested by the station. Single Action Pull Station UL for compliance to the latest requirements of the Americans with On dual action models, pushing the Disabilities Act (ADA). PUSH bar causes it to rotate inward, - , allowing the PULL handle to be grasped in a one handed motion. The dual action ' °. Lr . models are also supplied with break • UL Listed. r� , • CSFM approved. rods. Dual actions models are reset in r ..` { i • MEA (BSA) roved. the same way a single action models. ; 1: ( ) PP r= I, J LL • ADA compliant. • Weatherproof model approved for The weatherproof version of the pull ,. outdoor use. stations is provided with a gasket and die • Single or dual action. cast metal backbox tapped on one end r* • Terminals or wire leads. for 1 /2 -inch conduit, for surface mounting. • Key reset models use same keys as 11 Silent Knight enclosures. Dual Action Pull Station • Surface mount back boxes available. • High -gloss red enamel finish on die Y 7 cast metal. SILENT • Corrosion - resistant gold - plated �� contacts. ��1'�l IGI T 14 FIRE ALARM INITIATING DEVICES Die Cast Metal Manual Pull Stations Specifications Switch Rating: 1 amp at 125VAC, or 30VDC. Pull Station Dimensions: 4 in. H x 3 in. W x 1 in. D. Surface Mount Backbox Dimensions: 4 in. H x 3 in. W x 2 in. D (cast and sheet metal). Color: Red with raised white letters, white PULL bar with raised red letters. Accessories: All models are supplied with one scored acrylic breakrod and one hex wrench or key. ORDERING INFORMATION MODEL PART NO. DESCRIPTION PS -SATK 160050 Pull Station, Single Action, Terminal Connection, Key Reset PS -SAWN 160051 Pull Station, Single Action, Wire Leads, Hex Reset PS -DATK 160052 Pull Station, Dual Action, Terminal Connection, Key Reset PS -SATH 160053 Pull Station, Single Action, Terminal Connection, HEX Reset PS -DATH 160054 Pull Station, Dual Action, Terminal Connection, HEX Reset PS- SATK -WP 5310 Pull Station, Single Action, Terminal Connection, Key Reset, Weatherproof Box PS -WPB 160055 Weatherproof Box PS -BB 160056 Back Box PS -GR -12 160057 Box of 12 Scored Acrylic Break Rods WIRING DIAGRAM - TERMINALS WIRING DIAGRAM - WIRE LEADS Pull Screw Wire Terminals /� Leads To Fire i4 To Next To Fire ' To Next Alarm Device Alarm Device Control or ELR Control or ELR Panel Panel SILENT 11* KNIGHT 7550 Meridian Circle, Maple Grove. MN 55369 -4927 1- 800 - 446 -6444 or in Minnesota (612) 493 -6435 MADE IN AMERICA FAX: 1- 800 - 311 -1715 FORM #150792, Revs /96 INTELLIKNIGHT ACCESSORY Addressable P hotoelectric Type Smoke Detector I' P � : .'` Detect smoldering fires quickly and get help fast '� °. q with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS The light received is converted into an electronic si Under normal Analog /Addressable conditions, the status LED blinks ' a Photoelectric Type approximately every 15 seconds, ,,� ° -f . . i ndicating that the head is ` Smoke Detector t 1 communicating with the loop. The ‘, The SD505 -APS is particularly LED lights continuously during the suited to detecting dense smoke alarm period. typical of fires involving materials 0 ,, 4,' < such as soft furnishings, plastic, Features foam or other similar materials • Low profile, 2 inches, including which tend to smolder and produce base SD505 -APS Smoke Detector large visible particles. Simple and reliable addressing • The detector features automatic without mechanical switches Specifications compensation for contamination • Automatic compensation for Operating Voltage: 17 - 41 VDC and a simple detector calibration sensor contamination Current Consumption: test procedure that can be run from Built-in fire test feature Standby: .55 mA the panel or remotely (using the Alarm: .55 mA WindowsTM based downloading • Simple detector calibration g testing through the control panel Ambient Temperature: 32 °F to 100 °F software). (0 °C to 50°C) or remotely through a Operation WindowsTM based computer Mounting: 4" Square, 4" OCT, p Software. Single gang mud The SD505 -APS units made up of ring an LED light source and a silicon • Vandal- resistance locking Relative Humidity: 85% . photo diode receiving element. In a features noncondensing normal standby condition, the • Field cleanable Sensitivity: 0.88% - 3.57% FT receiving element receives no light • UL listed, meets NFPA 72 Ch 7 from the pulsing light source. In the requirements Air Velocity: 500 - 4000 FPM event or fire, smoke enters the • CSFM approved detector and light is reflected from the smoke particles to the receiving MEA approved SILENT element. it KNIGHT INTELLIKNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight 5820XL fire panel. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5- 15/16" Diameter = 3- 15/16" 11 N o \ •� i 8 o f r ' # Height = 2 inches, ! ` !( including base o laKNI SILENT Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) 10 SILENT KNIGHT - 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 612 -493 -6435 FORM# 350225, Rev. 01/00 FAX: 612-493-6475 Copyright ©2000 Silent Knight World Wide Web: http: / /www.silentknight.com INTELLIKNIGHT ACCESSORY M Model SD505 -ADH , . x ; Duct Smoke Detector -7 a , �. - t - �`' �� .�� kix i 4,1 . Detect smoke in air handling systems and air handeling equipment with Silent Knight's >_ addressable duct smoke detector The SD505 -ADH addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC air handling system. The SD505 -ADH is a heavy duty metal housing with a pre - installed detector base. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. The SD505 -ADH is designed to be used with Silent Knight's SD505 -APS Photoelectric Smoke Detector and SD505 -AIS Ionization Smoke Detector. Now there's even more power and flexibility available to the IntelliKnight family of products! Model SD505 -ADH Specifications Dud Smoke Detector Included Parts: Metal housing with 7.5" The Model SD -505 ADH Duct exhaust tube Smoke Detector is a heavy duty SD505-4AB detector base metal detector housing with a pre- Installation template installed detector base. The unit is -- c 4 mounting screws compatible with Silent Knight's i e Accessory (parts not included with SD505 -APS photoelectric and models: SD505 -ADH) SD505 -AIS ionization smoke SD505 -APS Photoelectric Smoke Det. detectors. SD505 -AIS Ionization Smoke Det. All features of the photoelectric I ,^' '' ' ' SD500 -ARM Relay Module and ionization detectors are STS -2.5 Sampling tube for 6" to available, including automatic drift Features z.s' duct width compensation for contamination • Two -wire connection to SLC STS -5.0 Sampling tube for 2.5' to com P 5.0' duct width and the automatic detector • LED alarm indication and STS -10.0 Sampling tube for 5.0' to calibration test. Detector calibration communication on sensor head 10.0' duct width can be checked from the panel or • Rugged steel backbox with clear remotely (using the IntelliKnight plastic cover Current: .a mA (alarm and standby) software with a WindowsTM based • Installation template included computer). • Air Velocity: 500 -4000 fpm (SD505 -APS) • Large terminal connection screws 300 -4000 fpm (SD505 -AIS) Operation • Interchangeable "plug -in" Air sampling is accomplished by photoelectric or ionization heads Sensitivity: 1.1 (SD505 % obs two tubes which protrude into the • 3 standard tube lengths 0.8 (SD505 -AIS) % obs - duct. An exhaust tube of one • UL listed, complies with NFPA 72 Ambient 32 °F to 100 °F standard length (7.5 ") is provided and 101 Temperature: (0 °C to 37 °C) with the detector housing. Intake • CSFM listed Humidity: 10 to 85% RH sampling tubes (ordered • MEAApproved 429 -92 -E, Vol 9 Dimensions: 10" H x 8.25" W x 2.25" D separately) are supplied in three • FM Approved standard lengths. Duct mounting is SILENT color: Gray accomplished through a template and 4 sheet metal screws fk KNIGHT (provided). INTELLIKNIGHT® ACCESSORY Model SD505 -ADH Duct Smo k e Detector Engineering Specifications The air duct smoke detector shall be Silent Knight Model SD505 -ADH. The housing shall contain a detector base, Silent Knight model SD505 -4AB. The detector housing must be compatible with Silent Knight smoke detector head models SD505 -APS (photoelectric) and SD505 -AIS (ionization). One detector head must be used for each SD505 -ADH used. The detector head must perform an automatic sensitivity check every 3 hours. The duct detector housing shall be of metal construction. Complete mechanical installation must be able to be performed without removal of the detector cover. Terminal connections shall be screw type using a minimum of #6 screw. SD505 -ADH Dimensions Front View Side View N • 69 � R Air 10" sampling tube \ 8.25" • 2.25" • 2.75" SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800-446 -6444 or in Minnesota 763 -493 -6435 FORM# 350216, Rev. 01/01 FAX: 763 -493 -6475 Copyright ©2001 Silent Knight World Wide Web: http: / /www.silentknight.com INTELLIKNIGHT ACCESSORY 1 ' Model SD500 -AIM --- -- • I 1 1 t i1 Addressable Input Module Olt And i! i A - C ! Model SD500 -MIM Fi Miniature Input Module - *-- -„;:,..',1, „---,-,-;... _E In telliKnight's addressable contact monitor modules 4 . . a c om bine fast response with pin -point location ID. A combination that saves lives and property. The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. Model SD500 -AIM and SD500 -MIM Input Modules The addressable input modules ' „I expand the flexibility of the �rsty IntelliKnight system by allowing the •,� � <,,„,� use of contact type inputs. Typical _ - applications include manual pull .: • stations and water flow switches. Features , x • Operates on Class A (Style 6 & ; Style 7) or Class B (Style 4)SLC Loop. 245Q9 -Alt 2375at -tdlii • Single contact monitor. Operation Specifications • Up to 127 modules per SLC loop. Each addressable input module is Operating Voltage: 24 VDC • SD500-MIM mounts in a single programmed with a unique SLC Standby Current: 0.55 mA gang box. loop address. The module Alarm Current: 0.55 mA supervises the wiring to the contact • SD500 -AIM mounts in a with an End Of Line (EOL) resistor. Ambient Temperature: 32 °F to 120 °F 4 "- square or double gang If a fault occurs in the wiring, the (0 °C to 49 °C) electrical box, and has an module alerts the FACP. Mounting: SD500 -AIM attractive ivory cover plate. double gang box or • SD500- AIM /MIM are DIP switch b "- square electrical box programmable. SD500 -MIM • Accepts up to 14 gauge wire. single gang box • Both modules UL 864 listed; comply with NFPA 72 • 2500 ft max. wiring distance from SILENT input module to contact. it C77 �� KNIGH • CSFM listed. s INTELLIKNIGHT ACCESSORY Model SD500 -AIM and SD500 -MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight 5820XL fire panel. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model 3D500=ABA FRONT VIEW BACK VIEW g DE VIEW Co i Y E Epp " i i — — -- ,—) (7' 1 n ..— i44....A.._ lam--- ;t:..S.a.— ta,. --. r' - -" AWN StIMIG4MM Vi M Y 44 SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 612 -493 -6435 FORM# 350231, Rev. 01/00 FAX: 612 -493 -6475 World Wide Web: http: / /www.silentknight.com Copyright © 2000 Silent Knight INTELLIKNIGHT ACCESSORY _ Model 5D500 -ARM Addressable Relay Module d , 1 ,,,,,,,,, 8 fr,: , „p4„ 0 F (,. -4,- „,,,,,,,, 4 .,,, .,,,,,,,,i Place relay applications anywhere on the IntelliKnight loop with the SD500 -ARM Addressable Relay Module. } The SD500 -ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500 -ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500 -ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. Model SD500 -ARM Features Addressable Relay Module • Two sets of Form C contacts. I� -' The SD500 -ARM provides two • Contacts are rated at 2A @ 30 Form C contacts rated at 2A © VDC or .6A @ 120 VAC. ; 30 VDC or .6A @ 120 VAC. • Up to 127 relays can be used on t , each SLC loop. These contacts can be used for I virtually any normally open or • Relay programming is normally closed application. completely flexible —can be Model SD500 - ARM mapped to zone conditions. • Polling LED visible through Specifications Operation cover plate. • UL listed, complies with NFPA Contact Rating: Form C Each relay module is 72. 2A @ 30 VDC programmed with a unique SLC • CSFM approved .6A @ 120 VAC loop address. When an event • MEA Approved, 429 -92 -E, Vol. 9 that controls the relay module Standby Current: .55 mA occurs, the relay is triggered by the IntelliKnight panel. Alain, current: 55 mA Ambient 32 °F to 120 °F Temperature (0 °C to 49 °C) it SILENT Mounting 4- square electrical box KNIGHT INTELLIKNIGHT ACCESSORY Model SD500 -ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500 -ARM. The modules shall be UL listed compatible with Silent Knight's Intelliknight 5820XL fire panel. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW EJTIOEai IkEvr.loit ROWER 0R1OR TO SERVICING s ' 3 [1:Wi ' ' g 4 3 2 4 4-718 :1f4 1 Y Model SD500 -ARM Addressable Relay Module Dimensions 10 SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 612 -493 -6435 FORM# 350218, Rev. 11/99 FAX 612 -493 -6475 World Wide Web: http: / /www.silentknight.com Copyright © 1999 Silent Knight z .• • 3a c5 /► ► .7EL ., l _ INC. WWI FIRE ALARM SYSTEMS Helping People Take ActionTM O N G �vF��N `� \ TM SERIES AS A Family of Multi - Candela Appliances- SINGLE & MULTI - CANDELA AUDIBLE STROBE APPLIANCES • SERIES AH AUDIBLES Description 2 � -Y Wheelock's patented 2 -wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with less current draw and Zero Inrush. Strobe options for wall mount models include 15/75cd or Wheelock's patent pending Multi - Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. SERIES AS SERIES AH Ceiling mount models are available in 15, 30, 75 or 100cd intensities. k yg9r'� The audible provides a selectable choice of either a 7:: continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. �r Additionally, the audible may be silenced while maintaining strobe activation on combination Multi - Candela Indicator Series AS units. (bottom of lens) All models may be synchronized when used in Features • conjunction with the Wheelock SM, DSM Sync Modules Approvals include: UL 1971, UL 464, California or the PS- 12/24 -8 Power Supply with Wheelock's State Fire Marshall (CSFM), New York City Patented Sync Protocol. • (MEA), Pending: Factory Mutual (FM) and Chicago (BFP). Y • ADA/NFPA/ANSI Compliant. • Wall mount models are available with Field Synchronization of the continuous horn tone provides the Selectable Candela Settings of 15, 30, 75 or 110cd temporal (Code 3) tone as mandated by NFPA -72 (1999) (Multi - Candela models) or 15/75cd. for all audible appliances. This ensures a distinct • Ceiling mount models are available in 15, 30, 75 temporal (Code 3) pattern when 2 or more audibles are or 100cd. • within hearing distance. If not synchronized, the Selectable Continuous Horn or Temporal (Code 3). • temporal sound may overlap and not be distinctive. At 3 Selectable dBA settings (99, 95 and 90 dBA) in both the same time, the strobes will also be synchronized. This tones. provides the ability to � Patented 2 -Wire Audible Strobe Appliance. P Y comply P Y with ADA • Patented Universal Mounting Plate. recommendations concerning photosensitive epilepsy • Strobes produce 1 flash per second over the regulated and NFPA standards when installing two or more visual voltage range. appliances within the field of view. • 12 and 24 VDC models with wide New UL "Regulated Voltage" using filtered DC or unfiltered VRMS All of this, plus the ability to silence the audible is input voltage. achieved by using only 2 WIRES. • Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12/24 -8 Power Supply with Wheelock's built -in sync protocol. • ZERO Inrush above Peak. • Compatible with all Wheelock 2 -Wire products. • Fast installation with IN / OUT screw terminals using #12 to #18 AWG wires. Copyright 2000 Wheelock Inc. All rights reserved. NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. etk WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR • APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. 4 . General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series AS Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85 %. • Series AH -24 homs are listed under UL 464 for audible signal appliances (Indoor use only). • Series AH -24WP audible appliances are listed under UL 464 for indoor /outdoor use with a temperature range of -31 °F to 150 °F ( -35 °C to 66 °C) and maximum humidity of 95 %. • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL 1971 Table 4: dBA Ratings for 12 VDC and 24 VDC Series AS /AH 12 and 24 VDC Audible Model Input Voltage VDC Regulated Voltage Strobe Candela (cd) Description Volume Reverberant dBA Anechoic dBA@ 10 ft Range VDCIFWR Per UL 464@ 10 ft AS- 24MCW -FR 24 18.0 - 33.0 15/301751110 High 91 99 AS- 2415W -FR 24 16.0 - 33.0 15 Cornuous Horn Medium 88 95 AS- 241575W -FR 24 16.0 - 33.0 15 (75 on Axis) Low 83 90 AS- 2430W -FR 24 16.0 - 33.0 30 High 87 99 AS- 2475W -FR 24 16.0 - 33.0 75 Code 3 Horn Medium 84 95 AS- 24110W -FR 24 16.0 - 33.0 110 - Low 79 90 AS- 1215W -FR 12 8.0 -17.5 15 Average Current • (AMPS) for Audible Strobe AS- 121575W -FR 12 8.0 -17.5 15 (75 on Axis) At the 3 Audible Settings @ 16, 24, 33 & 8,12 and 17.5 VDC AS- 24150 -FW 24 16.0 - 33.0 15 Average Current - wlh High dBA Setting (99 dBA) AS- 24300 -FW 24 18.0 -33.0 30 Voltage AS -2415W AS-241575W AS -2430W AS -2475W AS- 24110W 16.0 VDC .104 .124 .152 .240 .291 AS- 24750 -FW 24 16.0 -33.0 75 24.0 VDC .087 .102 .120 .177 .202 A5- 24100C -FW 24 16.0 - 33.0 100 33.0 VDC .090 .100 .119 .152 .183 Voltage AS -1215W AS- 121575W Table 2: Average Current • (AMPS) for AS -24 MCW Wall Models 8.0 VDC .303 .408 Average Current -with High dBA Setting (99 dBA) 12.0 VDC 223 256 Voltage 15cd 30cd 75cd 110cd 17.5 VDC .214 .251 16.0 VDC .095 .142 .242 .308 Voltage AS -2415C AS -2430C AS -2475C AS- 24100C 24.0 VDC .088 .120 .174 .224 16.0 VDC .130 .178 .357 .404 33.0 VDC .099 .120 .152 24.0 VDC .106 .135 248 .277 190 Average Current -with Medium dBA Setting (95 dBA) 33.0 VDC .102 .131 200 245 18.0 VDC .081 .128 .225 .296 Average Current -with Medium dBA Setting (95 dBA) Voltage AS -2415W AS-241575W AS -2430W AS -2475W AS- 24110W 24.0 VDC .068 .105 .157 .207 33.0 VDC .068 .090 .119 157 16.0 VDC .089 .108 .140 .224 276 24.0 VDC .072 .083 .105 .156 .183 Average Current -with Low dBA Setting (90 dBA) 33.0 VDC .067 .077 .092 .130 .158 16.0 VDC .077 .119 .222 294 Voltage AS -1215W AS- 121575W 24.0 VDC .060 .090 .142 200 8.0 VDC .251 354 33.0 VDC .055 .081 .109 .147 12.0 VDC .171 217 17.5 VDC .147 .182 Table 3: Average Current' (AMPS) Voltage AS -2415C AS -2430C AS -2475C AS- 24100C Series AH- 24 -RIW & WP 16.0 VDC .116 .164 .339 .389 VOLTAGE High Medium Low 24.0 VDC .091 .120 226 .258 18.0 VDC .035 .020 .014 33.0 VDC .079 .103 .179 .217 24.0 VDC .041 .024 .017 Average Current -with Low dBA Setting (90 dBA) 33.0 VDC .053 .030 .021 Voltage AS -2415W AS- 241575W AS -2430W AS -2475W AS- 24110W 16.0 VDC .086 .103 .135 218 271 24.0 VDC .064 .077 .098 .149 .177 SYNC MODULES I POWER SUPPLY 33.0 VDC .058 .067 .084 .117 .148 Input Voltage Average Current Mounting Voltage AS -1215W AS- 121575W Model Number Order Code (VDC) (AMPSVD 24 Options" 8.0 VDC 238 348 • 12.0 VDC .158 .194 SM- 1224 -R' 6369 24 .025 W 17.5 VDC .132 .162 Voltage AS -2415C AS -2430C AS -2475C AS- 24100C 05M- 1224 -R" 8374 24 .038 W 16.0 VDC .112 .160 .232 .382 24.0 VDC .082 .113 219 252 PS -1224-8 "' 8114 120 VAC 33.0 VDC .069 .095 .164 207 #SM Sync Module is rated for 3.0 amperes @ 24 VDC. • Average Current per actual Wheelock Production Testing at listed ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum VDC. For Rated Average and Peak current across UL regulated number of interconnected DSM modules is twenty (20). Refer to Data Sheet voltage range for both Filtered DC and unfiltered VRMS, see S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). Installation Instructions. ###Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24 -8 Power Supply. •° Refer to Data Sheet S7000 for Mounting Options. eOr °I.' • EVI EA &, h i 4 y . Fire Alarm Systems Helping People Take Action"' �P t° 0 R,NG ' F f IRE TM SERIES RSS & RSSP SINGLE C & MULTI- CANDELA STROBES A Family of Multi- Candela Appliances' & STROBE PLATES K G DESCRIPTION "' " Wheelock's patented Series RSS Strobe Appliances and rc Series RSSP Strobe Plates have lower current draw and Zero Inrush while maintaining outstanding performance, reliability and cost effectiveness. These versatile Series RSS Series RSSP appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. _ .. . Strobe options for wall mount models include 15/75cd or - "M , Wheelock's patent pending Multi - Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. Ceiling mount models are available in 15, 30, 75 or 100cd x ° .. intensities. Multi - Candela Indicator (bottom of Strobe Lens) All models may be synchronized when used in Features conjunction with the Wheelock SM, DSM Sync Modules • Approvals include: UL 1971, New York City (MEA), or the PS- 12/24 -8 Power Supply with Wheelock's California State Fire Marshall (CSFM), Pending: Patented Sync Protocol. Synchronized strobes can Factory Mutual and Chicago (BFP). eliminate possible restrictions on the number of strobes • ADA/NFPA/ANSI compliant. in the field of view. Wheelock's synchronized strobes • Meets OSHA 29 Part 1910.165. offer an easy way to comply with ADA recommendations • Wall mount models are available with Field concerning photosensitive epilepsy as well as meeting Selectable Candela Settings of 15, 30, 75 or the requirements of NFPA 72 (1999). 110 cd. (Multi - Candela models) or 15/75cd. • Ceiling mount models are available in 15, 30, 75 Wheelock's Series RSS Strobes employ a Patented or 100cd. Integral Strobe Mounting Plate that can be mounted to a • Low current draw with temperature compensation single gang, double gang, 4" square, 100mm European to reduce power consumption and wiring costs. backboxes or the SHBB surface backbox. If the flush • Strobes produce 1 flash per second over the regulated backbox has side or top space between it and the voltage range. finished wall, the NATP (Notification Appliance Trimplate) • 12 and 24 VDC models with wide New UL "Regulated may be used. It provides an additional .65" of trim for the Voltage" using filtered (DC) or unfiltered VRMS input Appliance. An attractive cover plate is provided for a clean, voltage. finished appearance on all models. • Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12/24 -8 The Series RSSP Multi - Candela Strobe Plates are a cost Power Supply with Wheelock's built -in sync protocol. effective way to retrofit required strobe appliances to bells, • ZERO Inrush above Peak. horns, chimes, multitones or speakers and easily mounts Compatible with all Wheelock 2 -Wire products. to standard 4" backboxes or for surface mount use with • Fast installation with IN /OUT screw terminals Wheelock's SBL2 surface backbox. using #12 to #18 AWG wire. Copyright 2000 Wheelock, Inc. All rights reserved. • NOTE: All CAUTIONS and WARNINGS are identified by the symbol 46.. All warnings are printed in bold capital letters. 44 WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, • SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN - PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series RSS & RSSP Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85 %. • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". Table 1: Specifications & Ordering Information - Multi - Candela Models - WALL MOUNT Input Regulated Average Current * Model Order Voltage Voltage Range Strobe Code Candela (CD) VDC VDC /FWR 15cd 30cd 75cd 110cd Mounting Options ** RSS - 24MCW -FR 9400 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 B,D,E,F,G,H,J,N,O,R,X RSS - 24MCW -FW 9401 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 B,D,E,F,G,H,J,N,O,R,X RSSP - 24MCW -FR 9402 24 16.0 - 33.0 15/30/75/110 .047 .081 .128 .166 D,E,Z Table 2: Specifications & Ordering Information - Single Candela Models Order Input Regulated Strobe Average Model Voltage Voltage Range Mounting Options ** Code VDC VDC /FWR Candela Current* SERIES RSS STROBES - WALL MOUNT RSS- 2415W -FR 7470 24 16.0 - 33.0 15 .051 B,D,E,F,G,H,J,N,O,R,X RSS- 241575W -FR 7471 24 16.0 - 33.0 15 (75 on Axis) .065 B,D,E,F,G,H,J,N,O,R,X RSS- 2430W -FR 7472 24 16.0 - 33.0 30 .081 B,D,E,F,G,H,J,N,O,R,X RSS- 2475W -FR 7473 24 16.0 - 33.0 75 .133 B,D,E,F,G,H,J,N,O,R,X RSS- 24110W -FR 7474 24 16.0 - 33.0 110 .161 B,D,E,F,G,H,J,N,O,R,X RSS- 1215W -FR 7475 12 8.0 - 17.5 15 .123 B,D,E,F,G,H,J,N,O,R,X RSS- 121575W -FR 7476 12 8.0 - 17.5 15 (75 on Axis) .170 B,D,E,F,G,H,J,N,O,R,X SERIES RSS STROBES - CEILING MOUNT RSS- 2415C -FW 7482 24 16.0 - 33.0 15 .072 B,D,E,F,G,H,J,N,O,R,X RSS- 2430C -FW 7483 24 16.0 - 33.0 30 .102 B,D,E,F,G,H,J,N,O,R,X Note: Models are available in either RSS- 2475C -FW 7484 24 16.0 - 33.0 75 .205 B,D,E,F,G,H,J,N,O,R,X Red or White. Contact Customer Service for RSS- 24100C -FW 7485 24 16.0 - 33.0 100 .238 B,D,E,F,G,H,J,N,O,R,X Order Code and Delivery. SERIES RSSP STROBE PLATES - WALL MOUNT RSSP- 2415W -FR 7792 24 16.0 - 33.0 15 .051 D,E,Z * Average Current per actual RSSP- 241575W -FR 7793 24 16.0 - 33.0 15 (75 on Axis) .065 D,E,Z Wheelock Production Testing at RSSP- 2430W -FR 7794 24 16.0 - 33.0 30 .081 D,E,Z Listed VDC. For Rated Average RSSP- 2475W -FR 7795 24 16.0 - 33.0 75 .133 D,E,Z and Peak current across UL regulated voltage range for both RSSP- 24110W -FR 7796 24 16.0 - 33.0 110 .161 D,E,Z Filtered DC and unfiltered VRMS, RSSP- 1215W -FR 7797 12 8.0 - 17.5 15 .123 D,E,Z see Installation Instructions. ** Refer to Data Sheet S7000 for RSSP 121575W - FR 7798 12 8.0 - 17.5 15 (75 on Axis) .170 D,E,Z Mounting Options SYNC MODULES / POWER SUPPLY Table 3: Audibles /Speakers for RSSP Strobe Plate Average Product Series Model Number Order Input Voltage Current Mounting Code (VDC) (AMPS) @ Options** 24VDC Multitone Appliances AMT, MT • SM- 12/24 -R" 6369 24 .025 W Horns AH, NH • DS M-12/24-R" 6374 24 .038 w Motor Bells MB - G6 /G10 PS 12/24 - """ 8114 120 VAC Speakers ET- 1010/1080, E70, ET70 # SM Sync Module is rated for 3.0 amperes @ 24 VDC. Chimes CH70 ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123) for SM and P83177 for DSM). ### Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24 -8 Power Supply. heeti o 3 INC. FIRE ALARM SYSTEMS '.�ADAj� CSFM 7135 - 0785:113 SERIES MB MOTOR BELLS Description Wheelock's Series MB motor bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB bells include higher dBA, low current draw, built -in trimplate for semi -flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB bells is a durable, high torque, permanent magnet motor selected for its high performance and long life. These DC vibrating Series MB motor bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. '"1 Series RSSP Non - Sync/Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. These 15, 15/75, 30, 75 and 110 candela strobe plates are designed for SERIES Americans with Disabilities Act (ADA) applications while meeting or MB exceeding the latest requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), and UL Standard 1971 (Signaling Devices for the Hearing Impaired). These strobe products, when properly specified and installed in accordance with NFPA/ANSI Standards, can • provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the 'illumination which results from ADA's strobe intensity guidelines of 75 K , I candela at 50 feet. This is an illumination of 0.030 lumens per square foot. ? °` By specifying and installing Series RSSP Non - Sync /Sync strobe plates, along with the Series SM or DSM Sync Modules, synchronized strobe flash is achieved. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Features Bell Plate SBL - 2 RSSP Remote Plate • Approvals include: Underwriters Laboratories UL 464, Factory Mutual (FM), California State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) on all models. • Meets OSHA29 Part 1910.165. • Built -in trimplate makes semi -flush mounting simpler and less • High sound output with low current draw. expensive. • Low frequency aluminum shells for better audibility through walls, • Screw terminals permit fast in- out field wiring of #12 to 18 AWG wire. doors, and other structures. • Polarized for DC supervision of NAC circuits. • 6" and 10" shell sizes in 12 or 24 VDC models. • Operate on filtered or unfiltered DC. • Integral RFI suppression to minimize induced noise on the NAC circuit. • For combined audible (bell) and visual signaling convenient retrofit plate • Mounting options for surface, semi - flush, outdoor, and concealed assemblies are available with 15, 15/75, 30, 75 and 110 candela conduit installation. strobes (Refer to Fire Alarm Products Catalog for strobe specifications and technical information). Architects and Engineers Specifications The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built -in trimplate for semi -flush mounting to a standard 4" square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Series RSSP 15 cd, 15/75 cd, 30 cd, 75 cd or 110 cd intensity strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in- out field wiring of #12 to 18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be red enamel. Ordering Information Model Order Shell Input Voltage Input dBA a Mounting*** Number Code Size (VDC) Current 10 n. Options DC VIBRATING MOTOR BELLS Notes: MB- G6 -12 -R 3942 6" 12 0.060 1. Typical dBA at 10 ft. is measured in an MB- G6 -24 -R 3941 6" 24 0.030 a bel chamber. 92 D, E, J, K, R, S 2. For bells all 12 VDC models are UL MB -G10 12 -R 3944 10" 12 0.060 rated for 9.0 to 15.6 VDC and all 24 MB- G10 -24 -R 3943 10" 24 0.030 VDC models for 18.0 to 31.0 VDC. Copyright 1997 Wheelock. All rights reserved. - - STROBE RETROFIT PLATES TO BE USED WITH MOTOR BELLS FOR COMBINATION SIGNALING Average "AVERAGE CURRENT SERIES RSSP WALL MOUNT APPLIANCES (24V) Nominal Current " Wall Only Voltage RSSP -2415W RSSP- 241575W RSSO -2430W RSSP -2475W RSSP- 24110W ' Order Voltage Strobe (Amps) Mounting 20 VDC 0.060 0.076 0.095 0.157 0.199 rr Model Number' Code (VDC) Candela @ 24 VDC Options "" RSSP- 2415W -FR 7792 24 15 .050 E,Z 24 VDC 0.050 0.065 0.081 0.133 0.161 RSSP- 241575W -FR 7793 24 15/75 .065 E,Z 31 VDC 0.043 0.052 0.066 0.108 0.131 P RSSP- 2430W -FR 7794 24 30 .081 E,Z RSSP - 2475W -FR 7795 24 75 .133 E,Z "AVERAGE CURRENT RSSP WALL MOUNT APPLIANCES (12V) RSSP- 24110W -FR 7796 24 110 .161 E,Z Voltage RSSP-1215W RSSP-121575W RSSP- 1215W -FR 7797 _ 12 15 .126 E,Z 10.5 VDC 0.148 0.189 RSSP- 121575W -FR 7798 12 15/75 .161 E.Z 12 VDC 0.126 0.161 15.6 VDC 0.102 0.130 SYNC MODULE SPECIAL NOTE: SM- 12/24 -R 6369 12 - .014 E,N 12 volt Wall Models (RSSP -1215W and RSSP- 121575W) will be available January, 1998. 24 - 025 E,N For applications requiring these appliances prior to this date, refer to Data Sheet #SO400 or call Customer Service for assistance. DSM- 12/24 -R 6374 12 ± .020 W 24 - .038 W Also available in white as a special order, please call customer service for order code and delivery information. Model code suffix: W = wall, F = fire or call Customer Service if other lettering is required (ex. Feugo), R = red, W = white (when 1st suffix). White will be considered a special order on this product. Example: RSSP- 2415W -FR Red Wall Fire "` Average current per actual Wheelock Product Testing @ 10.5, 12, 15.6, 20, 24, & 31 VDC Nominal Voltage. For rated average across the listed voltage range for both filtered DC and full - wave rectified (FWR), see the installation instructions (P83500). Series RSSP 12 or 24 VDC models in all candelas are for wall mount only. •-" Refer to Data Sheet S7000 for mounting options. SPECIAL NOTES 1. Series RSSP require the use of a SM or DSM Sync Module to attain synchronization of the strobe(s). (For more detail refer to data sheet S3000 or installation instructions [P83123 for SM and P83177 for DSM]). 2. SM Sync Module is rated for 3.0 amperes at 12 or 24 VDC; DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty. (Refer to Data sheet S3000 or installation instructions [P83123 for SM and P83177 for DSM]). Wiring Fig. 1 Bell Models Fig. 2 Retrofit Strobe Plate Models (RSSP) // \\ AUDIBLE VISIBLE l -/ t / I t - I t 1 0 "/ L - ^_ Ili PRECEDING APPLIANCE - . TO NEXT APPLIANCE FROM OR FACP OR EOLR PRECEDING + '■ + TO NEXT RED BLK BELL BELL OR OR FACP - - EOLR PRECEDING APPLIANCE ) - TO NEXT APPLIANCE OR FACP OR EOLR A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. 3 YEAR WARRANTY Distributed By: NATIONAL SALES OFFICE • 1- 800 - 631.2148 Canada 800-397-5777 E -mail: Info @wheelockinc.com 1113IA http://winniv.wheelockinc.com MEMBER , WHEELOCK, INC. • 273 BRANCHPORT AVENUE • LONG BRANCH, N.J. 07740 • 732 - 222 -6880 • FAX: 732 - 222 -8707 31500 Rev. P/9 Cheme ironic s ® ..., At Effective November. 1999 x Heat Detectors Series 600 The Heat Detectors Series 600 are supplied with the following standard features: • Rate -of -Rise and Fixed Temperature • Low Profile • One or Two - Circuit, Normally Open • Visual Indication • Easy Installation • Operation Testing Description The Series 600 Heat Detector is attractive, durable and features combination rate -of -rise and fixed temperature Junction Box Mounting Ceiling Surface Mounting operation. Heat detectors are available in 135 °F and 200 °F temperature ratings. + 6 { f t3l' 2 -1 /6 � Rate -of -rise detects heat by quickly responding to a rapid - 4 temperature increase. Rate -of -rise units have a wide spacing allowance of 50 -foot centers. See specification table for 3 - 1/4" or 4" Cut for surface Reversible details. Octagonal Box or mounting Mounting 4" Square Box Plate Fixed temperature reacts to heat by responding to a specific O temperature setting. 0 ° % Reversible Mounting Series 600 Detectors use the same reliable pneumatic rate -of- O �, Plate rise element of former models, but offer added aesthetic r `r / appeal. 11.1111111 The pneumatic rate -of -rise element responds to a rapid rise in . ' r i� temperature, approximately 15 °F. (8 °C) per minute, by =. expansion of air within the sealed chamber faster than it can •� °� escape through a calibrated vent. The resultant increase in pressure depresses the diaphragm, causing the electrical ` 8 - 32" 8 contact to close the circuit. Round Flat Head Head The fixed temperature element uses a fusible alloy. When Screws Wood activated, the external heat collector drops away to provide 5/8 to 1" - Screws quick visual confirmation that the element has operated. The units protrude only 1 -3/8 inch from the ceiling surface with a junction box mounting. They have pleasing contours and an all -white finish that conforms to ceiling aesthetics. Mounting plate is molded of white self- extinguishing thermo- plastic rated at 221°F (105 °C). The plate is extremely strong Installation yet adapts to uneven mounting surfaces. Each detector includes a patented reversible mounting plate. Series 600 Testing Methods In one position, it easily attaches to 4" square junction box, 3.25" or 4" octagonal box, or plaster ring. Models 601/621 and 602/622 can be tested by the quick • application of heat from any convenient source. A portable hair V In reverse, the plate can be used for open wiring without a dryer is recommended. However, do not apply heat that junction box. A 1/4" space between detector and mounting exceeds the fixed temperature rating of the detector. surface allows for wire connections. All mounting screws are Models 603/623 and 604/624 cannot be tested. However, the concealed. fusible alloy element used is considered so reliable that testing The detector attaches easily to the mounting plate with a push is not necessary. and twist motion. No tools are required. All rights reserved {10/99). • ta � rrr�r •iaue Chemeranics Q Effective: November, 1999 Model 601 and 621 Model 602 and 622 Model 603 and 623 Model 604 and 624 No Marking O Gray Ring © Gray Spot Gray Ring and Dot Model 601 (1 circuit) Model 602 (1 circuit) Model 603 (1 circuit) Model 604 (1 circuit) Model 621 (dua circuit) Model 622 (dual circuit) Model 623 (dual circuit) Model 624 (dual circuit) Rate -of -Rise and Fixed Rate -of -Rise and Fixed Fixed Temperature only, Fixed Temperature only, Temperature, 135 °F (57 °C) Temperature, 200 °F (94 °C) 135 °F (57 °C) 200 °F (94 °C) Applications: Normal Applications: Normal tempe- Applications: Unusually violent Applications: Unusually violent temperature fluctuations rature fluctuations and ceiling temperature fluctuations temperature fluctuations and and ceiling temperatures temperatures exceeding 100 °F and ceiling temperatures ceiling temperatures exceeding not exceeding 100 °F (38 °C) (38 °C) but not 150 °F (66 °C) not exceeding 100 °F (38 °C) 100 °F (38 °C) but not 150 °F (66 °C) Maximum Spacing Maximum Spacing Maximum Spacing Maximum Spacing Allowance* - Allowance* - Allowance* - Allowance* - 50x50 ft. -UL 50x50 ft. -UL 25x25ft. -UL 15x15ft. -UL 30 x 30 ft. - FM 30 x 30 ft. - FM 20 x20 ft. - FM 'Refer to National Fire Alarm Code Standard NFPA 72 for application requirements Important Special Notes Screw Terminals Application: Heat detectors should be used for property Standard Single Dual Circuit Detector protection. Reliance should not be placed on heat detectors for Circuit Detector Used to send two Independent Life Safety. signals. CAUTION: When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. Wire from alarm Wire connected to panel or previous next detector or Battery Back -Up: Heat detectors should be electronically detector. end of line resistor. supervised with battery back -up at the panel. \ • / The rate -of -rise mechanism may be subject to reduced (nil \p p/ sensitivity over time. Annual testing of the rate -of -rise mocha- Wire from alarm panel or previous nism is recommended. detector. / -4 • "C Electrical Ratings 44\ / \ 6 -125 Volts A.C., 3.0 Amps. 6 -28 Volts D.C., 1.0 Amps. Wire connected Wire connected 125 Volts D.C., 0.3 Amps. to next detector to next detector 250 Volts D.C., 0.1 Amps. or end of line or end of line resistor. resistor. Listings /Approvals NOTE: All single NOTE: All dual circuit models • Listed by Underwriters Laboratories (UL) circuit models come come with one (2) normally with one (1) open dry contacts. • Factory Mutual Approved (FM) normally open dry • California State Fire Marshal Approval (CSFM) contact. • City of New York (MEA) Listing No. 188 -94 -E • Listed by Underwriters' Laboratories of Canada (ULC) This literature is provided for informational purposes only. CHEMETRONICS assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact CHEMETRONICS, Ashland, MA; Telephone (800) 496 -8383. T il Chemetronics 400 Main Street Ashland, MA 01721 USA Phone: (800) 496 -8383 Fax: (800) 496 -7272 Website: www.chemetronics.com I ,µ All rights reserved (10/99) • AIR PRODUCTS & CONTROLS, LTD. • /12 PAM -1 MULTI- VOLTAGE RELAY MODULE PRODUCT DESCRIPTION The PAM -1 Relay is an encapsulated multi - voltage device providing 10.0 Amp - form C contacts. The relay may be energized by one of three input voltages: 24 V.A.C., 24 V.D.C., or 115 V.A.C. a " A red L.E.D. is provided which, when illuminated, indicates the relay coil is . µ °"`� energized. The PAM -1 may be mounted by using - k � the double -sided adhesive tape, the self- 1 '� "' drilling screw or loosely placed in a back box. These devices are ideal forapplica- tions where remote relays are required for control or status feedback. They are Actual Size suitable for use with H.V.A.C., Tem- perature Control, Fire Alarm, Security, Energy Management and Lighting Control Systems. UNDERWRITERS' LABORATORIES UL LISTED MODEL NUMBERS PAM -1 Single SPDT Relay with L.E.D., double -sided adhesive tape, mounting screw, 12" leads and 6 wire -nuts. INSTALLATION WIRING PRODUCT SPECIFICATIONS RELAY ENERGIZED L.E.D. Power Requirements: zoo WHT ► ��� BLU C C Per position - 0.015 Amps @ 24 YEL Nc 10.0 AMP V.D.C., 24 V.A.C., 115 V.A.C. , ' RED ORG N O CONTACTS Relay: Bum U.L. Recognized SPDT 115 V.A.C. @ 0.015A Contact Rating: 24 V.A.C. @ 0.015 A 10 A @ 115 V.A.C. 7 A @ 28 V.D.C., 24 V.D.C. @ 0.015 A 250 Microamps @ 5 V.D.C. Ambient Temperature: -50 °C to +85 °C 4 Approvals: Distributed By: Underwriters' Laboratories Listed Dimensions: 1.5 "(38.1 mm) Hx1 "(25.4 mm) W x .875" (22.2 mm) D with 12" wire leads 18 ga. Form No. PAM -I, Rev. 2 AP32 __ I� Lw �I 1 1 4 s — j