Loading...
Plans • grit µ R " t 4 ,. T ..4 p .� S r Y:, tti v f ''s a � • 1 ' f a i n e. s �-� eon. f• r f/ * f ir. • t 1 , ,� - f i A a .p. iikliir ,, � �,� e. c , -•sir ,'i E t fr.' `. `.: �,' Y ` 4 C 1 s . - se +y 41 z y : � yi.' �p rt � i h - ` ' k i W RL N. a " arf f f70 sw Al' 5 F = Carrier Gas Furnace 80,0000 BTU ! 59SP5AOSAE 17 -16 AC = Carrier Air Conditioner 4 ton I 24ACC648 � f B uz zi. " % � .�� `� a „ , tk . ,tt x 9u r ' ' 1 .sb r `� P S , s s c ., ,,,, :, ''- - -: ,: - : ,:' . ' ::,.. . ..g , p� � <,E � T r Y < T y Furnace SPECIFICATIONS Heating capacit and Efficiency 040 -10 060 4 080 -16 ,,,1 +0 -16 120 -22 Input High Heat (BTUH) 40,000 60,01s 80,000 1'0,000 120,000 Output High Heat (BTUH) 39,000 58,010 78,000 9:,000 117,000 Efficiency AFUE % (ICS) 96.5 96. 96.5 •6.5 96.5 Certified Temperature High Heat 40 - 70 40 - '0 40 - 70 4r, - 70 40 - 70 Rise Range °F (°C) (21 -38) (21- 8) (21 -38) '1 -38) (21 -38) Airflow Capacity; and Blower Data 040-10 060 - • 080 1 t - 16 120 -22, Certified External Static Pressure (in. w.c.) Heating 0.10 0.1' 0.15 1.20 0.20 Cooling 0.5 0.. 0.5 0.5 0.5 Airflow Delivery High Heat 695 100'• 1360 1730 2125 @ Rated ESP (CFM) Cooling 925 15# 1610 •720 2055 Cooling Capacity (tons) 400 CFM /ton 2 3. 4 4 5 @ 400, 350 CFM /ton 350 CFM /ton 2.5 4 4.5 5 6 Direct -Drive Motor Type Elect onically Commutated Mo , ECM) Direct -Drive Motor HP 1/2 3/' I 3/4 I 1 1 Motor Full Load Amps 6.8 8. 8.4 1.9 10.9 RPM Range 600 -1200 Speed Selections 5 Blower Wheel Dia x Width I in. 11x7 I 11 : I 11x8 I 1 x10 I 11 x 11 Air Filtration System :c ory Supplied Media Cabin t Field Supplied Filter Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1 • FR KGAWF1406UFR KGAWF 506UFR KGAWF1506UFR Etec* I $Oa. x l r• 0 0 10 : 0801$;... i r 16 120-22 - -----*Input Voltage Volts -Hertz -Phase 115 -60 -1 Operating Voltage Range Min -Max 104 -127 Maximum Input Amps Amps 8.1 9. r 9.7 1:.2 12.2 ---+ Unit Ampacity Amps 11.0 1 .0 13.0 ..' 16.1 Minimum Wire Size AWG 14 1 14 12 Maximum Wire Length @ Minimum Wire Size Feet 33 28 5 35 (M) (10,1) (8 •) (8.5) (11.7) (10.7) Maximum Fuse /Ckt Bkr (Time -Delay Type Recommended) Amps 15 1 15 -s 20 Transformer Capacity (24vac output) 40 VA External Control Power Available Heating 24.3 VA Cooling 34.6 VA co 1 ‘ 040,10 I 06044 I 000-16. Gas Connection Size 1/2" - NPT Burners (Monoport) 2 I I 4 1 5 I 6 Manufacturer White Rogers - Minimum Inlet Gas Gas Valve (Redundant) pressure (in. W.C.) 4.5 Maximum Inlet Gas 13.6 pressure (in. W.C.) Gas Conversion Kit - Natural to Propane KGANP50011SP Gas Conversion Kit - Propane to Natural KGAPN42011 SP Manufactured (Mobile) Home Kit KGAMH0301 KIT Ignition Device Silicon Nitride Limit Control 165 I 1 :0 I 170 I : ' I 160 Heating Blower Control (Heating Off - Delay) Adi .ble: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System none Thermostat Connections Y1, DHUM, G C W, Y/Y2, R Accessory Connections EAC (11; ac); HUM (24vac); 1 -stg AC (v . Y/Y2) - RECEIVED NOV 152011 CITY OF T GA,D 2 OFFICE �' BUILDh±C Di ViSfOti y Furnace AIR DELIVERY - CFM (BOTTOM RETURN WITH FILTER) INPUT RETURN - AIR SPEE EXTERNAL STATIC PRESSURE (IN. W.C.) BTUH SUPPLY 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 5(Gry) 1120 1080 1030 980 925 875 820 760 690 630 4(Yel) 880 845 810 780 740 710 680 640 615 570 40000 SIDE/BOTTOM 3(Blu) 695 665 620 575 535 495 455 420 370 280 2(Org) 640 595 540 495 460 420 370 310 260 230 1(Red) 570 525 475 425 385 330 255 220 - - 5(Gry) 1720 1670 1620 1565 1505 1440 1375 1295 1220 1135 4(Yel) 1325 1285 1255 1220 "1185 1145 1115 1075 1040 1000 60000 SIDE /BOTTOM 3(Blu) 1010 970 925 875 835 785 745 690 660 620 1(Red) 785 71 655 595 530 490 435 385 340 285 5(Gry) 1810 1770 1720 1665 1610 1540 1475 1400 1315 1235 4(Yel) 1535 1500 1475 1435 1405 1370 1340 1310 1245 1160 1 80000 SIDE /BOTTOM 3(Blu) 1380 1340 1305 1270 1240 1200 1165 1130 1090 1050 2(Org) 1180 1130 1095 1060 1015 975 935 895 850 800 1(Red) 1100 1045 1010 970 920 885 845 790 745 690 w 5(Gry) 2040 1970 1885 1795 1720 1635 1540 1450 1360 112 vim". 1 5 05r rW� .i, 30 _.- 1 5 100000 SIDE /BOTTOM 3(Blu) 1780 1730 1690 1645 1610 1555 1481 1400 1310 1210 2(Org) 1345 1295 1250 1195 1155 1105 1055 1000 955 915 1(Red) 1390 1350 1295 1260 1200 1180 1105 1050 1010 965 5(Gry) 2275 2230 2185 2130 2055 1950 1825 1710 1610 1500 4(Yel) 1875 1820 1770 1720 1660 1600 1550 1505 1450 1390 120000 BOTTOM OR 3(Blu) 2170 2125 2075 2025 1975 1900 1790 1695 1590 1470 TWO SIDES _ 2(Org) 1475 1420 1350 1280 1215 1165 1105 1050 995 930 1(Red) 1625 1565 1505 1445 1385 1325 1275 1225 1170 1130 *A filter Is required for each return —air inlet. Airflow performance included 3 /4 —in. (19 mm) washable filter media such as contained in factory— authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure. — Indicates unstable operating conditions. 5 _ • 1761 t� [176.11 I '41Z __{ FURNACE SIZE A B C D SHIPPING O (MODELS) (CABINET WIDTH) (OUTLET WIDTH) (BOTTOM INLET WIDTH) WEIGHT (598P5) Mabee mm inches mm Inches own Inches mm LBS KG 120.0 54.0 141.0 63.4 151.0 67.9 0 3 176.21 040-10 143/16 361 12 1/2 319 129116 322 7118 181 O VENT 060-14 1712 445 15 718 403 16 406 8314 222 -.-.0. 080-16 g 0 100-16 21 533 19318 492 191/2 495 1012 267 185.5 74.5 AIR IMAKE 12422 241x2 622 22 7/8 581 23 584 121!4 311 189.5 85.3 611/1b 1170.11 8901E ALL DMH4810N8 M INCH 84261 r 2611/16 ..a 291/2 ;678.1( (749.31 .... ____...__. _- ...__263/8 283/4 1670A1 1730.51 --. - - - -- - 251/8 2611/16 r 1638.71 1678.11 •-- -._ -_ - -_ 235/16 263/8 ti ti (592.91 (370x1 A r 1918 217/16 y. (485.81 1670.01 lli 8 r 211116 OUTLET WIDTH 15338] CA Q 6191 Q 0 AIR FLOW MR MdTANE 58 X73/4 f15.871 Apt FLOW 03 AIRFLOW • • (94.SF OASCONN (762] I.y r 07/8 L )A1 AIRIMAKE �1 A'4 r p� [22.21 rJ �, CONDENSATE DR4INTM GAS P �/ 16 GAS CONN \/ LOCATION A VENT ' .. I '.(22.21 ►� 17E631 0 78 22.21 err THERMOSTAT ENTRY IH (737/9 2 I 7/8 (2221 (22.21 POWER CONN THERMOSTAT ENTRY ,. • X78 078 1 1 1 / 122.21 _� (2221 POWER CONN 283/16 325/8 07/8 015.9] (8293] 35 (22.21 _ 3 2851726 18 1901 307!16 ,2872318 SIDE INLET X .1 . (0.4] SIDEINLET (22.21 /4 169/16 1513.9( (639.11 (7691 (609.71 tq4�� 1222.21 la 13/16 (420.91 2215/16 175/16 (581:91 201/4 169/16 1376.31 [4392] 1513.91 (420.9) - -� 1 11/16 I C ..-.1 I.-- 11/16 1 i *.t 1 ---.. (25.41 (1751 BOTTOM RETURN [17.51 15/16 J . 233/8 (25.41 22 WIDTM [333] (592.01 (5543] _ _ NOTE: Doors may vary by model. 21 26 5/16 (534.01 a. For 800 CFM- 16 -in. (406 mm) round or 14 1/2 x 12 -in. (368 x 305 min) rectangle. 1668.81 265/16 b. For 1200 CFM- 20 -In. (508 mm) round or 14 1/2 x 19 1/2 -in. (368 x 495 mm) rectangle. D5024.4 (66891 c. For 1600 CFM- 22 -in. (559 mm) round or 14 1/2x22 1 /16 -in. (368 x 560mm) rectangle. ° S " d. For airflow requirements above 1800 CFM, see Air Delivery table in these installation instructions for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0.5 in. W.C. E.S.P. D 0l PP MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N N N A/N A/N A/N N N 2 4 A C C 6 3 6 A 0 0 3 0 Product Product Major Cooling Grille Series Family Tier Series SEER Capacity Variations Open Open Voltage Series O =Not 0 -Not 3= 208/230 - 0 - 24 =AC A =RES AC C= Comfort C =Puron 6 =16 SEER A = Standard Defined Defined Original Series IP Outdoor Unit P.1-1, P uron. tie ■ CEaRTIFItu k us - w. n.�m,ecto.r.o,y �� the envlronmentaAy sound refrigerant ww C REGISTERED ENERGY STAR 0 This product has been designed and manufactured to 0 meet Energy Star® criteria for energy efficiency when .4 matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical N to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Maximum SEER * 16.0 16.0 16.5 16.5 16.0 16,0 16.0 Scroll Compressor X X X X X I X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X High Pressure Switch X X X X X X X Low Pressure Switch X X X X X X X Compressor Sound Blanket X X X X X X X Louvered Coil Guard X X X X X X X • * With approved combinations X = Standard PHYSICAL DATA UNIT SIZE - VOLTAGE, 18 -30 24 -30 30 -30 38 -30 42- • 48 -30 80 -30 SERIES Operating Weight lb (kg) 138 (61,7) 163 (73.9) 167 (75.7) 180 (81.6) 234 (106. 248 (112.5) ; 7 (152.9) Shipping Weight lb (kg) 163 (73.9) 198 (89.8) 204 (92.5) 219 (99.3) 281 (12 .5) 291 (132.0) • 2 (188.7) Compressor Type Scroll REFRIGERANT Puron® (R -410A) Control TXV (Puron® Hard Shutoff) Charge lb (kg) 4.60 (2.09) I 6.00 (2.72) I 6.81 (3.09) I 7.00 (3.18) 1 8.62 (3.!1) I 10.50 (4.76) I 1 • 50 (6.58) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1881 2614 2614 3223 381 4046 4046 Motor HP 1/12 1 /10 1/10 1/12 1/5 1/4 1/4 Motor RPM 1100 800 800 800 80. 800 800 COND COIL Face Area (Sq ft) 11.50 15.10 17.20 17.60 25.1 20.10 30.15 Fins per In. 25 25 25 25 2 20 20 Rows 1 1 1 1 1 2 2 Circuits 3 4 4 4 6 7 8 VALVE CONNECT. (In. ID) . Vapor 3/4 3/4 3/4 7/8 7: 7/8 7/8 Liquid 3/8 3/8 3/8 3/8 3/ : 3/8 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 1 7 8 I 1 1/8 Max Liquid Line 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when u ' : other sizes and lengths .f lineset. Note: See unit Installation Instruction for proper installation. t See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 2 °° ELECTRICAL DATA MAX OPER VOLTS* COMPR FAN MIN MIN MAX MAX FUSE** WIRE WIRE LENGTH LENGTH UNIT SIZE V /PH MCA SIZEt SIZEt ft (m)$ ft (m)# or MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C AMPS 18 -30 48.0 9.0 0.50 11.8 14 14 67 (20.4) 64 (19.5) 20 24 -30 58.3 13.5 0.70 17.6 14 14 46 (14.0) 43 (13..1) 25 30 -30 64.0 12.8 0.70 16.7 14 14 44 (13.4) 41 (12.5) 25 38 -30 208/230/1 -60 253 197 77.0 14.1 0.50 18.1 12 12 57 (17.4) 54 (16.5) 30 42 -30 112.0 17.9 1.20 23.6 10 10 85 (25.9) 81 (24.7) 40 • 48 -30 109.0 19.9 1.20 26.1 10 10 70 (21.3) 67 (20.4) 40 60 -30 135.0 21.4 1.20 28.0 8 10 91 (27.7) 56 (17.1) 40 * Permissible limits of the voltage range at which the unit will operate satisfactorily t If wire is applied at ambient greater than 30 °C, consult table 310 -16 of the NEC (NFPA 70). The ampacity of non - metallic- sheathed cable (NM), trade name ROMEX, shall be that of 60 °C conditions, per the NEC (NFPA 70) Article 336 -26. If other than uncoated (no- plated), 60 or 75 °C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70). # Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time -Delay fuse. FLA - Full Load Amps LRA - Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps c0 NOTE: Control circuit is 24 -V on all units and requires external power source. Copper wire must be used from service disconnect to unit. U All motors /compressors contain internal overload protection. Q Complies with 2007 requirements of ASHRAE Standards 90.1 CV A- WEIGHTED SOUND POWER LEVEL (dBA) Unit Size - Standard TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) Voltage, Series Rating (dBA) 125 250 500 1000 2000 4000 8000 018 -30 73 49.5 58.5 64.5 69.0 63.0 59.5 52.4 024 -30 74 54.5 62.0 67.0 71.5 66.0 62.0 53.0 030 -30 74 56.0 62.5 66.0 68.5 64.5 61.0 53.5 038 -30 72 52.0 61.0 64.0 66.0 61.0 58.5 51.5 042 -30 74 56.5 61.5 65.0 66.5 63.5 61.0 56.5 048 -30 73 58.0 61.0 65.0 66.0 62.0 58.0 51.0 080 -30 74 56.5 82.5 66.5 68.0 63.0 59.5 51.5 NOTE: Tested in accordance with AHRI Standard 270 -08 (not listed in AHRI). CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE) UNIT SIZE - VOLTAGE, SERIES REQUIRED SUBCOOLING °F ( °C) 18 -30 10 (5.6) 24 -30 10 (5.6) 30 -30 10 (5.6) 38 -30 10 (5.6) 42 -30 9 (5.0) 48 -30 10 (5.6) 60 -30 9 (5.0) 8 • a DIMENSIONS - ENGLISH UNIT 55 ELECTRICAL A B C D E F G K L M N P OPERATING SHIPPING SHIPPING CHARACTERISTICS WEIGHT (bs) WEIGHT (bs) DIMENSIONS L x W x H) 24ACC618 0 X 0 0 0 25 3/4' 28 11/16' 3 3/4' 3/4' 4 7/16" 21 1/4' 1 13/16' 2 13/16" 112' 13 1/4' 13 3/4' 12 3/4' 136 163 26 7/8' X 30 1/16" X 32 9/16' 24ACC624 0 R 0 0 0 31 3/16' 28 5/16" 3 3/4' 314' 6 9/16" 24 11/16" 9 1/8' 2 13/16' 1/2' 15 5/8' 15 1/2' 14' 163 198 32 3/8" X 35 1/2' X 32 9/16' 24ACC630 0 0 0 0 0 31 3/16' 32 5/16' 3 3/4" 3/4' 6 9/16" 24 11/16" 9 1/8" 2 13/16' 112' 16 1/2' 15' 14 3/4' 167 204 32 3/8' X 35 1/2' X 35 15/16' 24ACC636 0 X 0 0 0 35' 28 5/18' 3 7/8' 7/8' B 9/16" 28 7/16' 9 1/8" 2 15/16' 518" 18 1/4' 16 1/8' 14' 180 219 36 1/8' X 39 5116" X 32 0(16" 24ACC642 0 X 0 0 0 35' 39 1/8" 3 7/8' 7/8" 6 9/16" 28 7/16' 9 1/8" 2 15/16' 5(8" 18' 16' 17 1/2' 234 281 36 1/8" X 39 5/16' X 42 3/4" •-•—•—••• 24ACC848 0 X 0 0 0 35' 32 5/16' 3 1/8' 1/8' 6 9/16" 28 7/16' 9 1/8' 2 15/16' 578' 17' 17 1/2' 14' 248 291 36 1/8" X 39 5(16' X 35 15/16" 24ACC660 0 X 0 0 0 35' 45 15/16' 3 7/8' 1 /6' 6 9/16" 28 7/16' 9 1/8' 2 15/16' 5(8' 17 1/8' 18 5/8' _ 20 1 /4' 337 372 36 1/8' X 39 5/16' X 49 9/16' 0 NOTES: CD in O X= YES c4 o c W � 0 = NO 1. ALLOW 30' CLEARANCE TO SERVICE SIDE OF UNIT, 48' ABOVE UNIT, 6' ON ONE SIDE 12' ON REMAINING SIDE, cgl 6 AND 24' BETWEEN UNITS FOR PROPER AIRFLOW. O N N m 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING !V MODE IS 55 MAX. 125 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY di>. 5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. A SO. M AIR AIR IN DISCHARGE AIR DISCHARGE G j M r r IIIIIIIIIIIIIIIIIII I II IIIII I FIELD CONTROL IIII11111111111111 I II �e SUPPLY CONN. $ 7/B' HOLE II11 I�� 11 1 1 1 1 IIIIIII IIIIIIII I II B AIR IN FIELD POWER SUPPLY CONN. L nnnrnn mmninn n„1 ) -.------AIR IN �/ F 0 7 /6' HOLE WITH `� Jl y61 1/8' KNOCKOUT o 11111111111111111111 11111111 \. �__ N LIQUID LINE CONN. „ I! ' IIIIIIIIIIIIIII P � • l s� � E / + i 1 b 1 7/8' f L 5/16"-- O DVAPOR LINE CONN. K IAIR IN MINIMUM UNT SIZE MOUNTING PAD 03/8' TIEDOWN KNOCKOUTS DIMENSIONS 12) PLACES 18 26' X 26' 24,30 31 1/2' X 31 1/2" 36 THRU 80 35' X 35' 24ACC6 . °i CERTIFIED., www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4765146 Date: 11/11/2011 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 24ACC648A * *30 Indoor Unit Model Number: CNPV *4821A ** Furnace Model Number: 59 *P5A080E17 * *16 Manufacturer: CARRIER AIR CONDITIONING Trade /Brand name: COMFORT 16 PURON AC Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING p 9 Y Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 42000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.50 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION A LAOS The information for the model cited on this certificate can be verified at tivtivw.ahridirector Air- Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on 11® 1S.� and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No.. which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129655279670074672