Loading...
Plans �i SUPREME COMFORT INC. 9425 S.W. COMMERCE CIR. # 16 RECEIVED WILSONVILLE, OR 97070 ce 682 -1985 cc DEC 08 7 -1 Gas piping sized for: CITY OFT1Gh.TI'I ul cD 7 "WC Nat. Gas c % ; 25e Equiv. ft. BUILDING Drsi ?:: ;d 550HBLU /Hr `,�' m W r - ` 3 Remove or abandon unit heelers O - m _ `d `c 1 w g' 1 „ Exlsttng 2" - - • - . .. �� a f, o .=• w Venta a CTH2 -108 Existing t -t /2" . Existing 2 ". © - to • a__p —_ ®0 a = + K xi { ' II I O O O O O = O O '., O fn ~ C c� o m • 1 ' • van ag6 - 8 y : M 0 0 a e , l' :I o C r, q ftR Tj .. VTR 4 ' , - Yantsl�s CTH2 -125 '. /tilde ref act • ���� T • ,L r+ $ � �� Z c�oonnditionally Approved............... [ J I c CD _ w�a s -t Cis - �) � �. i 3 � T G " ►1�`?y/* el-GOr Date V ca StyleShock Cheer and Dance "- ., Vantage® Tube Heaters scale: l = 20' co a Radiant Tube Heaters V al Date: 11/14A)8 "" Tigard, Oregon E = .1 Savi • Products, Inc. OFFICE COP - - • I/mm=00000w ,.... :i. •„.. 4-, ,,,,,,,,,,4,4z,,,„,,,t,,.:,%;:,:,,y,-,,:‘qii,,,„,„„.:,,,:., ,.,. ..... . . . .. . ,. . ..., , , .....„.„ . .. ,. ,..% , , , , i,:,:: , ":;:::: - Years of field-proven product performance 0. Diagnostic NI capab ilit y ,,,, Burner box design with incorporated ted in burner design protective enclosure for Design flexibility achieved controls minimizes exposure . to dirt and moisture from with straight, U-tube or L configurations and a broad combustion air range of burner sizes and m Longer life provided by tube lengths durable components W; ,m., N' ,„ ,,,, % , . „. sNN, ',1 1:‘,1 :4) M . - ",, 1* ', 04AN:k: .::.':',:::, - , 4 .,„ ,", N AV !!!::*4,*, W' -'''''' V '' 1 ! : ',i5IV W ni. _.; .,r ;w1 g%i ...04 00 0t It , .,",,I‘,' a a a ali % °M 'k i .., ?., .' ' °':: ., Ms ',,,- :* vw ,.. ..k , , ''''' ' ' ''' i t,v' .k, • :.N 1:::k , -v 1/4 ,,-,°, a ; % a %:, '‘a ' a ‘a A% 1 4'1! a a I aa dt g: C K ), '.:K ": • Z 41 10 1 0 1 40 kk A 00 04 Nc o Ot NI , - , , Ko i. , :.,m ;,,, , ,:o: il; i m ',, \' 'Ig : Vi N i=',C P i ':W: StN Ike* ! t4' o: 4 24! 0 ' 0 0\ = 4t1 4i ', 0° 0004 '001V : - 00M ,., Selling The Standard in Unitdru Infrared Heating icton,10 t, s i G s 0 , o CERTIFIED (csl i'TIV . _ Quality in Any Language --A TM '.il e r I i a Burner End View , Side View To p View ie di • Reflector " __ .... -_I r. . _ r.. .n 1 �� 4A mI ►I - _ — __ . - - . " I p - - (457 mm) - a Turbulator (Some Models) r "" e— ; I. I, Minimum Length 'A" Minimum length `a' Overall Minimum Length 17' ) 4 Overall Minimum Length `e• VANTAGE' H Model CTH2 -40 CTH2 -60 CTH2 -80 CTH2 -100 CTH2 -125 CTH2 -150 CTH2 -175 Minimum Length of Straight Tube (ft, in) A 10 20 20 _ _ 30 _ 40 50 60 Minimum Length of U -Tube (ft, in) B N/A 11,7 11,7 16,7 217 26,7 31,7 Overall Minimum Length of Straight Tube (ft, in) C 11_5.5 21,5.5 21,5.5 31,5.5 41,5.5 51,5.5 61,5.5 Overall Minimum Length of U-Tube (ft, in) D N/A 13,0 .5 13,0.5 18,0 .5 23,a 5 28,0.5 33,0.5 Input (Btu /h) x (1000) -- - 40 _..... - ....... _ 60 ._ - _. _...._.._ ._...._.---- 100 125 150 175 Fuel Natural Gas (NG) or Propane Gas (LP) Inlet Pressure (in wc) NG min. 4.6 4.6 4.6 4.6 4.6 4.6 5 LP min. 11 11 11 11 11 11 11 14 maximum for NG & LP Gas Connection NPT 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" Electrical Supply 120 V, 60 Hz, 1 A (Run) 5 A (Start) Heat Exchanger Tubing 10 ft Sections, 4" dia, 16 Gauge, First 10 ft ALUMI - THERM° Steel Tubing (Remaining Hot Rolled, Heat Treated Aluminized or Double Porcelain Coated Steel Tubing) Exhaust Flue 4" dia Reflector and End Cap_ s......._._.___ ................._.._._._....__._............._.-._.___.—_._....._ ................_- _024Aluminum (Optional - .024 Stainless Steel Type 304) _.._.....___ - Control System Honeywell° SmartValve °II Combines Gas Valve and Hot Surface Electronic Ignition Control Fully Automatic_Four_Try, 100% Shut -Off, Prepurge, Auto Reset, LED Indicator Status Approved As Indoor (Vented or Unvented) Certification ANSI Z83.20 /CSA 2.34, 2.17 Warranty Three-Year Limited (Refer to Installation, Operation and Service Manual for Details) Weights Burner (lb( 40 Overall Length of Tube and Accessory Packages (ft) 10 20 30 40 50 60 70 Hot Rolled or Aluminized Tube with Aluminum Reflector (lb) 52 86 120 161 206 240 281 Aluminized Tube with Stainless Steel Reflector (lb( 66 113 152 208 265 304 360 U-Tube Packages (lb) Aluminized Tube with Aluminum End Caps 19 Aluminized Tube with Stainless Steel End Caps - ......._._._.... ...._...._.._...._20.._........ _........._. - ..........._.. Clearances to Combustibles* (inj Model CTH2 -40 CTH2 -60 CTH2 -80 CTH2 -100 CTH2 -125 CTH2 -150 CTH2 -175 Horizontal 45° Horiz. 45° Horiz.45° Horiz.45° Horiz.45° Horiz. 45° Horiz. 45° Horiz. 45° L A 6 8 6 8 6 8 6 10 6 10 6 12 8 12 .-v -- 8 27 8 35 8 38 8 40 8 46 8 50 8 52 8 C 53 51 63 60 66 66 71 74 77 78 80 84 82 85 1 a D 27 46 35 54 38 60 40 64 46 69 50 74 52 79 *Clearances B. C, 0 can be reduced by 50% for locations 25 ft (7m) or more downstream of the burner. For other mounting options and associated clearances, complete installation, operation and service criteria, please see the current issue of the VANTAGE° II Installation, Operation and Service Manual. Installation Code: ROBERTS GORDON' products are to be installed only in accordance with local laws, codes and regulations, and only by a contractor qualified in the installation and service of gas -fired heating equipment. This product is not for residential use. Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON" North American independent distributors Please contact us for' any further information you may require, including the VANTAGE' ll Installation, Operation and Service Manual, Roberts - Gordon Roberts- Gordon 1250 William Street 76 Main Street West P.O. Box 44 Unit 10 Buffalo, NY 14240 -0044 USA Grimsby, Ontario L3M 1R6 Canada Telephone: 716.852.4400 Telephone: 905.945.5403 Fax: 716.852.0854 Fax: 905.945.0511 Toll Free: 800.828.7450 European Office: Roberts - Gordon Telephone: +44(0) 1902 494425 www.rg - inc.com Fax: +44(0) 1902 403200 ©2005 Roberts - Gordon All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without written permission of Roberts - Gordon. Printed in U.S.A. CTH2SNA 5M 0205 Rev. F '. Fas sent by : 5036928831 ENERGY SAVING PRODUC 12 -04 -08 01 :57p Pg: 2/2 Vantage SeismSeismic r int Support Chain Taut Chain i r - -Slack Chain / • Slack Chain /. • /' t Chain Tumbuckie 4" Tube Tube & Reflector Hanger at burner. • Taut Chains Limit Side Movement To Essentially 0. o Slack Chains Provide Sufficient Slack For Normal Expansion Of System Only, Then Limit Further Movement To Essentially 0. • Slack or Taut 'Chains' may be chain, cable, or wire with a working load limit of 139 lbs or more. ® Provide Seismic Restraints At Burner end of heater.