Loading...
Permit a ' Y OF TIGARD BUILDING PERMIT PERMIT #: BUP2007 -00037 COMMUNITY DEVELOPMENT DATE ISSUED: 1/25/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S135AB-01004 SITE ADDRESS: 10220 SW GREENBURG RD 200 ZONING: C -P SUBDIVISION: LINCOLN CENTER /TWO LINCOLN LOT: JURISDICTION: TIG Project Description: CRUISE MASTER Fire alarm modification. REISSUE: `p5 FLOOR AREAS EXTERIOR WALL CONSTRUCTION m CLASS OF WORK: f r FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 2FR sf N: S: E: W: OCCUPANCY GRP: B TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 2,175.00 Owner: Contractor: EQUITY OFFICE PROPERTIES TRUST T & L COMMUNICATIONS INC ONE SW COLUMBIA #300 PO BOX 87387 PORTLAND, OR 97258 2800 NE 65TH AVE SUITE A VANCOUVER, WA 98661 Phone: Contact #: PRI 360 737 - 9725 FAX 360- 737 -9648 FEES Reg #: LIC 67787 Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 1/25/2007 $72.10 [TAX] 8% State Surcha 1/25/2007 $5.77 [FLS] FLS Pln Rv 1/25/2007 $28.88 Total $106.75 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 -001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Permittee Signatur li i� Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 4 Fire Protection System Building Permit Application I o-R (EI?1CI USE ONLY City of Tigard R C I V E : 1 l J 2.5/01 £ ' Permit No. I y� lay) _ 13125 SW Hall Blvd., Tigard, OR 97223 Pao Rene j '"' ' • >s ,, .. Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit: ( f Inspection Line: 503.639.4175 JAN 2007 Date Ready/By: Juric 10 See Page 2 for TI GARD Internet: www.tigard- or.gov F TIGARD -r Supplemental Information CITY T Y" OF �'IGAR ® " 13?4:; t' . x Sc;4•d '.° :?1llf. r 3:r ? a* ::' v4' i !:�?:_'S�:4�4; <R"F' AU:= � ° au ' r • r tR h�..:T,VNA """^0.,4 V,Ii.f;�iree4.1v : *r a. 3c.. a ,� e �..c,:, � . � � §« .,d,, `�tys;'`:='"' t - ,;x : �_, . � ,s xsir_ .:.a n`a:.,raan."•.�sw- w � °, Ti, ',; el 7 aat y - CW:: . a ltdat ktTYEE t )F U ;r :46 4 zt ; 'x .n c N • I) AN Ft1 sw ''��.. r � r , ;;�� . .� .< � � �'� , y �� .�'.��.' -,' ;:. �.� :�-' � " RE . IRS a �NIII;YD. Lti � �+�eY�Br r�t.2 -:s4 , >. �a�.; ��x�. �nvex;,! �;. wg::;:,.<. a�, AMS>' �. �. �_ �,,. �, F a n,:. T#z 41 , e�r_ ' , - �kM�. • s�,:.vts ' Y.�'�,' • . t� a: ags,+ �. f....., r9�' aszW „ei3�rv�� ?laz;;'!H�:ar irk' a�� k- i'+ "a:Cv� %��x? ?:a�tS ±l�,�&�8 =�v�.� ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the :. -,. ; n 7 .- c S ri ; a. +�.snr..-.; ::nrr:,s..v:;;:.. ;ire:sz,41,�:ilre+'_ .w .�, ..-. •o < , r: `,��:� � '� � x Ala �� �i- � work indicated on this application. 4, ' i i ` = 'CATEGORYtOF CONSTRUGTI01 . ,tis .' = " ,_. t ' "� aPP ❑. r.>:.;, �• W,,,.+ a.,..!.. �,,. u. �.; �s> sn::= cee.., �, �n.: aa- s�:,+-< 3.:!' c•: 4-..:. mep�! s,>`:;^-:- r, s`. a:: xr. EaY=' n.+; w.» se!'.- i!xi..a..�..ti�..:,s..�.�;�c�� ..:::,a:�za�:i a. Valuation: $ ❑ 1- and 2- family dwelling © Commercial/industrial ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: ;Ha t: *u' ^ > % r .. m ...,., ;;w :- ;: , teas "ice:: t : r a ; v .u:a H x: i Y =(''xazv �,S:fi k " t 1 ' 11t,. JO egifE,tINFO rANDr3 rdifo i y, k Total number of floors: Job site address: 10220 SW Greenburg Road (Two Lincoln) New dwelling area: square feet City / State/ZIP: Portland, OR Garage /carport area: square feet Suite/bldg. /apt. no.: Suite 200 I Project name: Cruise Master Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet • f•lx:'s•>.� Id " ' its, �'+ Girk>:..,. S; iiSf:f. �,Y.:'h::.asar�rTtsS.:.tB ".'avw a� t '� "f i Am D'AATA COIVIMEI2CIAI yirdH1i`GI o Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all a:: =R ,., 5 h �� .,�', � : i'. ',. sr r a:sx.4z r.-.rs „ *: "d �'� " ,:i''`°,� `a - "'..tip',. -..,ti,^ , and the profit for the equipment, materials, labor, over ea a e ro , ifit� , � vi ta l ? IP Th OF atidtI � 40' � � , work indicated on this application. Fire alarm modification for tenant improvement Valuation: $ 2,175.00 Existing building area: square feet New building area: square feet . v ", � 41' \ .,..,4dvlr-_Y.,- ,...YU¢Y': ,,-... 3,.� ,, it "':44 ,,,,, A • ,,Te ..„- ,ma:,..2.,,,,,. , hir, 1 -1 n } tzt9 P.ERTi Y <1�W iVEI�' „> o ` , a ,, , t nrg tg a : Number of stories: ..z: r.+” s .:, . � ,.�s�n�t�'r,�ee-,;,:x�?�iw..�a. , ,r�rz,�''r'.,I�`i��...:�. �..�vA`��< ..,- n_�?�...,�.¢....,. - . _ �ua ��,.�..r Name: Type of construction: Address: Occupancy groups: City /State/ZIP: Existing: Phone: ( ) Fax: ( ) New: ' i �`.'¢.q.''. -. ..�.� ;; m' :�+'�i�' „ '7h''' �r /c. ':i3•Y'vt� = --. ..m�i,`�.oue7e:.a�-u•�:. „�x,:,r +..x.ca:- •r�.u7�.xe� a - - - - : �. ,,•`;� 4�il - Wi -; ,fb - .aa .., ea�s . tt v„kvv —,, �u' ass; + - %.d.FS ,'. ®yAYYLICAN'1' . , . • �'” =;�� - ,�CONT:��T °PERSUN " ��-•,'...'.' °'�: - �. < -. _,�..t. � - . �- :- �.,t „�.:: . , . ......:. ��,.. � >. <_.� w�n�< e-�:�..x:�>l�.z,�,,:h „"gym >., .-� ;; - _� -�'t�'��f�'"`�; 1V(1TICE���^�` ���`�” Business name: T &L Communications, Inc. All contractors and subcontractors are required to be Contact name: Ross Bushaw licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: PO Box 87387 jurisdiction in which work is being performed. If the applicant is exempt from licensir^ a-- o_ "- --•'ng reasons City/State/ZIP: Vancouver, WA 98687 app t Phone: ( 360 ) 737 -9725 1 Fax: : ( 360) 737-9648 , _ .:, - E -mail: office @ tl- communications.com .�'�'` ;�w- t;`,:1:i,:.'t,`s. >-� � . a'?" a _ � - _ ram ;mzra,°'�'z'.r�t <ars: -� �z�tr,- �tw <tx:•• ��ss�r�� '� :ta.��” ' .. .va'' " =''(iUNTRAC'IUR ` : •VV•,_,-V,,., s� r 1 - x� '-u� � c >�.. n� �i+� - - r . ;: Kr' Y' w�. ~�'�B `:'�I3IIiDING''EPRI�'M1Tw' 4` -E .�•� �,, �is��'�i�.r�*2, k����, �i ..;�i <1��,4- w- .��',m';srca..... ,,a:asc..w,�� :a..+�a���ixw!�YwM:.�h.�<� �,.,�3 ,4., k'EES" .:�'.: r '. e� Business name: T &L Communications, Inc. ):•11, <CQSe:" fe8 's c hedu te l a Address: Permit fee: ' •7 i PO Box 87387 City /State/ZIP: Vancouver, WA 98687 State surcharge (8% of permit fee): S . Phone: 36 737 -9725 !Fax:( 360) 737 -9648 FLS plan review (Due upon — o of permit fee): ( ( (Due upon application.) zr CCB lie.: 67787, Portland Metro 6981 Total permit fees: / Authorized signature: Amount received: �o This permit application expires if a permit is not obtained I Print name: Larry Bushaw Date: 1/25/07 within 180 days after it has been accepted as complete. L_—.... * Fee methodology set by Tri- County Building Industry Service Board. '/ I:\ Building \Permits\FPS- PermitApp.doc 03/23/06 4404613T(I I /02/COM/WEB) lt I 8 -life 1,�., C "1 - Co 3 4 FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 -31 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: �. f u i l C mt,sig 5 � �' y Address: r Z Representative of protected property (name, phone): Authority having jurisdiction: Address/ telephone number: C1-1-1.._ Organization name / phone Representative name / phone Installer mtl , t C- G,v, - n i, 1,10-)1,)- 5" Z C cr"' � Supplier. c � • Service organization: Location of record (as -built) drawings: t"%►. 5, rt. Location of operation and maintenance manuals: ■ CT- l( CM/ O.fa C.c Il , d� Location of test reports: '"y �) rUL� A contract for test and Inspection In accordance with NFPA standard(s): Contract no(s): Effective Date Expiration date: System (a) Operating system (executive software revision level(s): (b) Site - specific software revision date: (c) Revision completed by: (name) (firm) 1. Type(s) of System or Service NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving alarm: Alarm Supervisory: Trouble: If alarms are retransmitted to public fire service communication center or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communication center or others, indicate location and telephone numbers of the • organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Central Station Prime Contractor: Central Station Location: I FIGURE 4.5.2.1 Record of Completion (NFPA 72 , 1 of 4) 0 a „ 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Mutiplex One -way radio Digital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System Location: NFPA 72, Chapter 9 - Auxiliary Indicate type of connection: Local energy Shunt Parallel Telephone Location of telephone number for receipt of signals: 2. Record of System Installation (Fill out after Installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching but prior to conducting operational acceptance tests.) This system has been Installed in accordance with the NFPA standards as shown below, was inspected by on ,Includes the devices shown in 5 and 6, and has been in service since L NFPA 72, Chapters (check all that apply) ❑ 1 ❑ 2 ❑ 3 04 [2. 5 ®.6 ®' 7 a. 090,9 ❑ 11 NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (specify) Signed: 0 Date: . ) ^ G) Organization: di L Lbyyw, 3. Record of System Operation Documentation In accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by Date: and found to be operating property in accordance with the requirements of: NFPA 72 , Chapter (check all that apply) ❑ 1 ❑ 2 ❑ 3 04 ❑ 5 ❑ 6 ❑ 7 ❑ 8 ❑ 9 10 ❑ 11 NFPA 70, National Electrical Code, Article 760 L Manufacturer's Instructions Other (specify) Signed: Date: ) ' Z )` G ) Organization: L. 64-rimy, 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72 table 6.6.1): Quantity: Style: Class: (NFPA 72, 2 of 4) FIGURE 4.6.2.1 Continued • FUNDAMENTALS OF FIRE ALARM SYSTEM 72-33 5. Alarm- Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5) Quantity: Style: Class: MANUAL (a) Manual stations Noncoded Transmitters Coded Addressable (b) Combination manual fire alarm and guard's tour coded stations: AUTOMATIC Coverage: Complete Partial Selective Nonrequired (a) Smoke Detectors Ion Photo Addressable (b) Duct Detectors Ion Photo Addressable (c) Heat Detectors FT RR FT/RR RC Addressable (d) Sprinkler Waterflow indicators: Transmitters Noncoded Coded Addressable (e) The alarm verification feature Is disabled or enabled , changed from seconds to seconds. (f) Other (list): • 6. Supervisory Signal- Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded stations (b) Noncoded stations (c) Compulsory guard's tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour SPRINKLER SYSTEM Check if Provided (a) Valve supervisory switches ❑ (b) Building temperature points ❑ (c) Site water temperature points ❑ (d) Site water supply level points ❑ Electric Fire Pump: (e) Fire pump power ❑ (f) Fire pump running ❑ (g) Phase reversal ❑ Engine -driven Fire pump: (h) Selector in auto position ❑ (i) Engine or control panel trouble ❑ G) Fire pump running ❑ ENGINE - DRIVEN GENERATOR (a) Selector in auto position ❑ (b) Control panel trouble ❑ (c) Transfer switches ❑ (d) Engine running ❑ Other supervisory function(s) (specify): FIGURE 4.6.2.1 Continued (NFPA 72 , 3 of 4) 72-34 NATIONAL FIRE ALARM CODE 7.Annunciator(s) Number: Type: Location: 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones : Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): pp Quantity: t Style: [ Class: D Types and quantities of notification appliances installed: (a) Bells With Visible (b) Speakers With Visible (c) Horns With Visible 1 1.. (d) Chimes With Visible (e) Other: With Visible (f) Visible appliances without audible: 5 po I- u. IA f use 6 wd (3cli s 9. System Power Supplies (a) Fire Alarm Control Panel: Nominal Voltage: Current rating: Overcurrent protection: Type: Current rating: Location: (b) Secondary (standby): Storage Battery Amp -hour rating: Calculated capacity to drive system , in hours: Engine - driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency system used as backup to primary power supply Emergency system described in NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s); System deviations from the referenced NFPA standard(s) are: • C r-e, '2- - /7 ) (signed) fo ' nstallation contractor /supplier (title) (date) (signed) for alarm service company I (title) I (date) (signed) for central station I (title) I (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) I (date) FIGURE 4.5.2.1 Continued (NFPA 72, 4 of 4) ., � ` �U ��~�� ��������������� ����'m����'n mn���mna�� BUILDING,. ON PERMIT #: OUP2007-00037 13125SVV Hall 8lv2��l DATE ISSUED: 1/25/2007 Phone: (503) 639-4171 Inspection Requests (24 Hrs.): (503) 639-4175 "� ^�� INSPECTION WORKSHEET FOR DATE: 2/21/2007 TIME: 7:008m PAGE: 80 SITE ADDRESS: 10220 SW GREENBURG RD 200 CLASS OF WORK: SUBDIVISION: L|NC0LWCEMTEQ/TWO LINCOLN LOT #: TYPE OF USE: PROJECT NAME: CRUISE MASTER DESCRIPTION: CRUISE MASTER Fire alarm modification. OWNER: EQUITY OFFICE PROPERTIES TRUST, PHONE #: CONTRACTOR: T & L COMMUNICATIONS INC PHONE #: 360-737-5725 Inspection Request Scheduled For: Date: 3/21/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 998 Alarm final 043609-01 603-780'3222 Y Corrections/Comments/Instructions: k AI .. 1 i ,.._ _ , ,m o iiii r imiliamor.twoomp *J .__ illigifildginumw I ... 1 ASS . El PARTIAL APPROVAL I] CANCEL n NO ACCESS n FAIL CALL FOR INSPECTION ADDITI AL F ES ASSESSED Inspector / Date: �~� 7.--"( � � � Phone #: (503) 718- ------- t- ` ' ' �� .. .