Loading...
Plans Nu/c r ` f • A $ Baltimore AJrcofl Company 0 Your BAC Representatives in Oregon and SW Washington Equipment Submittal Date: August 23, 2006 To: Smitty © American Heating RECE VE Project: Lincoln Center ocT D claw OF Tritagi Model Number, VF1- 018 -02H Ull� 1 E1 � 1� Quantity: 1 Capacity: 60 USGPM of Water from 95 F to 85 F with 68 F entering air wet bulb temperature. Fan Motor: One (1) 5 HP fan motor: totally - enclosed, fan - cooled (TEFC), inverter duty, suitable for 460 volt, 3 phase, 60 hertz electrical service. CTI Certification: CTI Certified Thermal Performance Materials of Construction: Steel Panels and Structural Members are Constructed of Galvanized Steel Fan Wheel Material: Galvanized Steel Fan Wheel(s) Coil Type: Galvanized Steel Coil Drift Eliminators: Polyvinyl Chloride (PVC) Drift Eliminators Water Outlet: End Outlet for Integral Pump Spray Water Pump Assembly: Close - Coupled Centrifugal Spray Water Pump with Electrical Requirements Matching Fan Motor(s)' Spray Piping: PVC Spray Distribution Branches Basin Heaters: Electric Immersion Heaters Sized to Maintain +40 °F water at a 0 °F Ambient with Electrical Requirements Matching Fan Motor(s) Basin Heater Controls: Electric Immersion Heater Controls Basin Water Level Control: Mechanical Float Valve Assembly Ph — 360 -883 -3962 Fax — 360- 885 -3188 Your BAC Representatives in Oregon and SW Washington Baltimore Alrcbt! Company CTI Certification: The thermal performance of this BAC unit has been certified through performance tests conducted by the Cooling Technology Institute in accordance with their standard STD -201. Such certification by an independent third party assures engineers and users that the published thermal capacities accurately reflect the actual unit performance. CTI certification eliminates the additional costs of on -site, individual unit testing, oversizing the equipment or operating cost penalties from deficient equipment. Materials of Construction: All steel panels and structural elements of the unit are heavy -gauge G -235 (Z700 metric) galvanized steel. This is the heaviest galvanizing commonly available in the industry, and is the accepted standard for evaporative cooling applications. This standard corrosion protection system will provide reliable protection and long life for most industrial cooling, air conditioning and refrigeration applications. The five -year warranty provided on all BAC evaporative cooling equipment is the most comprehensive fan motor and mechanical equipment warranty available in the industry. Included in the five -year warranty are the mechanical equipment support, fan(s), fan shaft(s), bearings, sheaves, and fan motor(s). Fan Wheel Material: The centrifugal fan wheels will be constructed of galvanized steel. Coil Type: Coil(s) will be 1.05" O.D. all prime surface steel tubes encased in steel framework with entire assembly hot - dipped galvanized after fabrication. Tubes will be sloped for liquid drainage. Coil(s) will be pressure tested to 375 psig air under water. Drift Eliminators: Drift eliminators will be constructed of polyvinyl chloride (PVC), and will be removable in easily handled sections. They will impart three distinct changes in air direction to effectively strip entrained moisture from the leaving airstream with minimum air resistance. Water Outlet: The spray water outlet will be a pipe stub, sized for pump suction, and located at the standard pump suction location. Spray Water Pump Assembly: A close - coupled, bronze -fitted pump with a mechanical seal will be mounted on the basin. A drainage connection will be provided to allow free draining when the basin is drained. The pump motor will be totally enclosed, fan cooled (TEFC). Ph — 360 - 883 -3962 Fax — 360- 885 -3188 A Baltimore AircoII Company 0 Your BAC Representatives in Oregon and SW Washington Spray Piping: Water distribution system is constructed of Schedule 40 PVC spray branches. Basin Heaters: Units exposed to below freezing ambient temperatures require protection to prevent freezing of the basin water when the unit is idle. Heater selected to maintain +40 °F basin water temperatures provide you with a simple and inexpensive way of providing such protection. Factory installed heaters are electric immersion heaters. Basin Heater Controls: The heaters are installed in the basin and are controlled by a remote thermostat with the sensing bulb in the basin. A low -water cutoff switch prevents heater operation unless the heater elements are fully submerged. Basin Water Level Control: Bronze make -up valve with unsinkable polystyrene filled plastic float arranged for easy adjustment. The make -up valve is suitable for water supply pressures between 15 psig (103 kPa) and 50 psig (345 kPa). Ph — 360- 883 -3962 Fax — 360 - 885 -3188 B.A.C. Closed Circuit Cooling Tower Selection Program Release 6.2 NA Age Program data and calculations are correct as of Oct. 1, 2003. Copyright © 2000 Baltimore Aircoll Company, Inc. All rights reserved. 44 u To: American Heating Inquiry No.: Attn: Smitty Project Name: Lincoln Center From: Tom Berger Date: Mar. 6, 2006 Selection Parameters Model & Fan Motor Model Accessories Product Line: Series VF1 Unit Intake Option: (None) Number of Units: 1 Unit Internal Option: (None) Model: VF1- 018 -02H Unit Discharge Option: (None) Coil Type: Standard Coil Unit Access Option: (None) Standard Total Fan Motor External Static Pressure: 0.00 in. of H2O Power Per Unit: 5.0 HP Fan Motor: Standard Motor Total Pump Motor Power Per Unit: 0.5 HP Maximized Capability, per Unit, Wet Operation Thermal performance for this selection is certified by the Cooling Technology Institute (CTI). Flow Rate: 64.22 GPM Fluid: Water Heat Rejection: 320,972 BTUH Fluid Pressure Drop: 0.95 psi Entering Fluid Temperature: 95.00° F Leaving Fluid Temperature: 85.00° F Wet Bulb Temperature: 68.00° F Range: 10.00° F .. BAC- 11544A 20000BoKimore Pircoil Company. M Was Resolved. 3' -6 1/4" 17 1/8" 13" ...._r 12 1/8" 1/2" FPT VENT \� I I 0 4" BFW FLUID OUT •IllIIIIIIIIIIIIrIIIIIIIIII O Pit:: IN . 4" MPT DRAIN 0 4" BFW FLUID IN WITH CAP I _ _ _1=. MPT MAKE_U I �, ,i I.::::: _ .. 1 I I I v a I _2 " M OVER 11 �� � ' 1 ' \ e 1 , ' M co I N me la " \ .: t `� Y MPT DRAIN ;Q i 1 I • ' l i l t 2 1/4" --. lo I-- I 13 1/4" -- (- 6' -0 "" 1 BFW BEVELED FOR WELDING. M 17 1 /4" -- G4 () FAN MOTOR LOCATION. 30" L- 0 E —MOTOR LOCATION. -- 3'-11 1/2 "" UNIT NORMALLY SHIPS IN ONE PIECE. APPROX. APPROX. HEAVIEST MODEL NO. SHIPPING OPERATING SECTION F H WEIGHT WEIGHT (COIL) VF1- 018 -02 2175 2635 2175 • 13 1/4" 6' -7 1/4" E— II 4r1 010 12 - . . " /'1 T'1 . ��� _ . " " ACCESS access NOTES: 1. ALL DIMENSIONS ARE IN FEET AND INCHES. WEIGHTS ARE IN POUNDS. 2. UNLESS OTHERWISE INDICATED. ALL CONNECTIONS 6 INCHES AND SMALLER ARE MPT AND CONNECTIONS 8 INCHES AND LARGER ARE BEVELED FOR WELDING AND GROOVED FOR VICTAUUC CONNECTION. 3. DIMENSIONS SHOWING LOCATION OF COIL CONNECTIONS ARE APPROXIMATE AND SHOULD NOT BE USED FOR PREFABRICATION OF CONNECTING PIPING. 4. FOR SUPPORT REQUIREMENTS, REFER TO THE SUGGESTED STEEL SUPPORT DRAWING. B.A.C. RIGHT HAND UNIT ORDER NO: � BALTIMORE AIRCOIL END OUTLET WITH PUMP COMPANY DRAWING NUMBER: DATE: 0 BAC- 11544A I c . , • BAC - 15839A 2000(0 Baltimore &coil Company. All Rights Reserved. , . , . II ' • i ' 1 I i il f i i 1 1 1 , i i I ; I i i i 1 I i i 1 ,L2 1 m El N S 0 N,'. * q I i AiR ENLEI ciDE .-" -- .. ) NO. .,,.. ,,, .r". :.!. : .7,r?. 5) i I' . / L-OUTUNE OF UNIT ....1. DF :::, A suffv.y 1: A:,-,- 'N , ,,q, i-: F_Nr: LDIEL =,.• 542 ? ;,.., !,54, 17:p -E F&,, ,:r. a c- 5545 f .,-.,„ , ..: , ! .--, W , ._OP,D T(3 EACH 9EM 3LAF,.. :-.-,3H , . - ' , E 1 - .-',G - - - .. ,- -.C.C , D"--Tf;: , Ct.... 1 3/5 - 41V,50550 si * (REFER TO CHART) - 1 - :Nc; Hc: AR' 71/.;3 Di P-..i INC ( ..:=CAMCi.J:::, '....' . r ) : h:. ':::, RI: , - :. , UE - :•. 7 E: E Ci it f YO VENUS :55 i555450P ;3./..- S ij 0 C E. S ;1:. ,,') 5 E ::;., su pi 1 ::, T P f'-.C,; (irs \',, --,', .7 i :',f' -'.,- V: 0 .it _:: A.1 P. (I ', I , ,TR i ' ---- — - — .-- C,/I ,,. ,,..s DRAWING NUMBER: