Loading...
Specifications 1,u 6r 97079 ,54J e( American Veterans Security 01 SW 135 Ave. �1\ I verton, OR 97008 REG v 503.469.9554 FEg °.1*5 00 SI LD I146 Fire Plan Southwest Church of Christ 9725 SW Durham Rd Tigard, OR 97224 John Kelly American Veterans Security 503.319.4754 OFFICE COPY ` T American Veterans Security 8301 SW 135 Ave. Beaverton, OR 97008 503.469.9554 January 30, 2005 SW Church of Christ — Fire Plan Vista 128FB Fire panel 6128 Fire keypad one 2WT -B System Sensor smoke det Five Wheelock Series MPS Pull Stations Nineteen Wheelock Series NS -24MCW Hornstrobes One Amseco MBA dc (24vdc) 10" Bell 24vdc 12 AH backup battery Possible connection to new riser at a later date N0Gt) eoti v Fcr Tv S u"Povs c ■ • Honeywell ADEMCO VISTA -128 FBN128 FB -24 Commercial Fire and Partitioned Alarm Platform Designed to integrate seamlessly with CCTV, access addressable V -Plex technologies. A diverse line of control and Honeywell's full range of fire and burglary Honeywell initiating devices, notification circuits, digital components, the VISTA -128FB provides the ultimate dialers, keypads, RF receivers and relays support this protection of life and property. The UL listed extremely powerful control platform. The VISTA -128FB Commercial Fire and Burglary Control Platform controls has been designed to mount quickly and easily up to eight partitions, and supports up to in an attack resistant cabinet, and is available in 128 zones /points using hardwired, wireless and 12V and 24V models. FEATURES • Supports addressable V -Plex • Stores up to 512 events and can • Can control eight separate area access control points using accommodate 150 user codes independently (8 partitions) VistaKey (1 to 8 doors) • New E2 software simplifies • Two on -board notification (bell) • Supports up to 15 doors of programming circuits delivering 2.3A @ 12V or access control using Vista .Easily programmed and 3.4 amp @ 24V Gateway Module (VGM)* maintained with newly upgraded • Automatic smoke detector • Supports CCTV applications with Compass Downloader software sensitivity maintenance testing the new VistaView 100 CCTV • Eight hardwired zones standard, switcher module expandableto 120 V -Plex p • Connects to Honeywell's Passpoint Access • Identifies the point or zone of a fire addressable points /zones Control Systems. Maximum 32 doors. or alarm, using the new FSA -8/ or 128 wireless points /zones FSA -24 Fire system annunciator • r w ADEMCO VISTA- 128FBN128FB -24 Commercial Fire and Partitioned Alarm Platform SPECIFICATIONS Cabinet dimensions Additional Features — Up to 50 two - wire glass break • 18 "H X 14.5 "W X 4.3 "D • Notification Appliance Circuits detectors on zone eight Environmental (two) • Patented addressable V -Plex • Storage temp: 10 °C to 70 °C — Programmable polling loopV-Plex technology: • Operating temp: 0 °C to 50 °C — Temporal code compliant — Supports up to 120 two -wire • Humidity: 85% RH — Individually silenceable zones /points EMI • Programmable on -board auxiliary — Global polling technology for relay faster processing Meets or exceeds the following • SIA false alarm reduction — Increased current draw requirements: features: capacity — FCC Part 15, Class B Device P tY (128mA) — FCC Part 68 — Exit Error Logic — Supervised by panel — Exit Delay Reset — Individually assignable to — IEC EMC Directive — Cross Zoning partitions, notification circuit p; Agency Listings — Call Waiting Defeat (bell) output or aux relay r , : Burglary — Recent Close Report — 4,000 ft capability without the • UL609 Grade A Local Mercantile • Supports commercial hardwired, use of shielded cable Premises and addressable V -Plex polling loop — Extender /Isolation bus module • Mercantile Safe and Vault and wireless zones — Two -wire smoke detector • UL611/1610 Grades A, AA, • Hardwired zones: zone /group expansion module Central Station - Provides nine style B adds two or four zones • UL365 Grades A, AA Police hardwired zones — Eight zone - Class A and B Connect — EOLR supervised for Fire and Extender Module Fire UL burglary installations • — One zone supervised Contact • UL864 /NFPA72 Local, Central — Supports N.0 or N.C. sensors Monitor Module Station and Remote Station — Individually assignable to one • UL Listed wireless expansion • Factory Mutual or all eight partitions — Supports up to 128 wireless • California State Fire Marshal — Up to 16 two -wire smoke zones using 5881 Receiver • MEA detectors each zone 1 and 2 • UL985 (32 total) I VPI•x Loop I __ I I L l _ I Tifiic GIas56r Sensor E 4 „ v4 Atla plet 5172 Belles ∎ Expansion Module 06tect Moo le i With Two Class A - V-PLEX Loop _ ` _. :,. 58BW zones Commercial Receiver 5 Qn 1 ,,,, II Ali i Con xw VlsteKey V -Flex 1 V4staVlew -100 Access Control CCN Malule Swittlnr Notification Appliances 4204 NAC I IBeq Circuit Relay 4204CF }I- Eight Class B Hardware Zane 4146 51401 Key Comnaticata I Switch Status Modie { � ir 4100ter 1. _ M Pun mace Module RS232 Notification Appliances 82205 Printer IAN Phone lJne to Central Slauon i 1 7720lRF Long II 7845C Comb, Ranoe Redo Honeywell — Supervised by control for Applications Alarm power check -in signals Supported by a diverse line of • 12VDC, 1.7A max for each — Tamper protection for Honeywell initiating devices, the notification (bell) circuit output transmitters powerful VISTA -128FB is the ideal Aux. standby power — Individually assignable up to integrated fire and burglary control • 12VDC, 1A max eight partitions for applications where a higher Total power — Supports UL864 /NFPA level of security is necessary • approved wireless smoke including medical and professional from all 12VDC, 3.4A at 24VDC from all sources detectors buildings, supermarkets, churches . • Access control integration and synagogues, office buildings, Standby — Full integration with PassPoint • 24 hours with 1A standby load or 9 schools, universities, strip malls, Access Control System larger residences and factory or 60 hours with sing 3 max Complete Gateway in access warehouse environments. standby load using 34AAH functions Installation battery • Event reporting The VISTA -128FB alarm system has Fusing • Local printer of access or VISTA been designed to mount both • Battery input, aux. and notification related event quickly and easily in an attack (bell) circuit outputs are protected • Scheduled uploading of events to resistant cabinet. It meets all using PTC circuit protectors. All central station applicable requirements for UL outputs are power limited. • Stored events for one call retrieval commercial burglary installations. Main dialer • Communication Electrical: • Line seize: — Phone mapping by zone Primary power: — Double Pole response type — 18 VAC@ 72 VA No. 1451 — Supports VIP Interactive Phone Quiescent current draw: Voice Module — 300mA — Panel operation during Backup battery download — Uploading equipment list to • 12VDC, 12AH min to 34AAH max central station • Lead acid battery (gel type) — Communication to PassPoint via Vista Gateway Module (VGM) I I Manta Pull Stations Stat •-c 1 5140MPS - 1' -t 5140MPS - 2' WNW V 41905N 1; L12260SN Mretiplex V -Flex Two-Zone s DUAL TEC Motion Detector ?7aDC Quad PtA 4193SN Expender 4944SN Serial inteAue Addressable Module 1 Recessed Mount 1111 Contact ■ Temper Switch' 5881 _..i._._..._.. �Q Flow Switch' Wireless Receiver �fl Law Tenn Bch' . . ECP Bus (Max Two) 61398 Snwl,e S i di 32 Character \ Red -Apha DetwY °s w oou PIP r Keypad 58C0 Sams Devices (- 7 4204CF a ''4 E' zatalyT, _ 4111641Iss 41111 Module d:�_ OoodNh,dow Sr5801BLaT _...t_,,. .- .d..,.. haNakee Detectors -slelaM�s,,, support. up To is Cf TmaritOx Two- �11F % VVtrs Notification � . 4 014111 4 . Smoke Detectors MPllrenrce • Sass Carmardal � � Fold -Up Svatch 581708 _ _- . Wieless � OP T - Transmitter VGM(PfVGM) owe* -/a\. Yana Gateway Supports Up To 84 Mole Conventional Two-Wire PassPoint Smoke Detectors Honeywell ADEMCO VISTA- 128FBN128FB -24 Commercial Fire and Partitioned Alarm Platform SPECIFICATIONS Ringer equiv. • 4190WH Two Point Multiplex RPM Upgraded software — 0.713 • 4193SN Two Zone Serial Interface . Upgraded Compass Downloader Formats: Modul Windows compatible — ADEMCO Low Speed, ADEMCO • 4208U Loop Expansion Module - Wireless devices eight zones 4 +2 Express, ADEMCO High • 5804 - Wireless Key • 4208SNF Class A/13 Expander Speed, ADEMCO Contact ID, • 5804BD - Bi- Directional Key Sescoa and Radionics Module • 5804BDV - Bi- Directional with • 4209U Group Zoning Module - Auxiliary devices voice • 6160CR Alpha Keypad two /four zones • 5816 - Door/Window Transmitter Commercial Fire • 4293SN One Zone Serial Interface • 5819 - Shock Sensor Module • 5827BD - Bi- Directional Keypad • 6139R Red Alpha • 4297 Isolation /Extender Module Keypad /Annunciator V (addressable) smoke 5849 - Glassbreak Detector • FSA -8 & FSA -24 Fire System • 5881 Series - RF Receiver Annunciator detectors supporting 5800 wireless • 4204 - Relay Module, four form C • 5192SD detectors contacts • 5192SDT • 5890 - PIR • 4204CF - Two supervised output Passive infrared detector Access control circuits • 998MX • VistaKey V -Plex (addressable) • 6220S - System printer used with • 4275EX -SN Access Control 4100SM Serial Interface Module • 4278EX -SN • VistaKey -SK Starter Kit • 5140DLM, FSA -8, FSA -24, • Quest 2260SN • VistaKey -EX Expansion Kit FSAKSM Fire Annunciator V - Plex (addressable) contacts • VGM Vista Gateway Module to Two - wire and four - wire smoke • 4939SN -WH PassPoint Access Control detectors conventional: • 4944SN -WH (Honeywell Access Systems) • System Sensor smoke detectors • 4959SN CCTV Horn /Strobes Glassbreak detectors • VistaView 100 - CCTV Switch • System Sensor notification • 9500SN Module appliances VISTA Interactive Phone Module Commercial wireless devices Manual pull stations: • 4286 Voice Module • 5869 - Hold up Transmitter • 5140MPS -1 Optional 24V power supply • 5817CB - Wireless Commercial • 5140MPS -2 • PS24 - 24V power supply - 3.4A Transmitter V - Plex (addressable) devices: Long range radio • 5881ENHC - Commercial • 4101SN Single Relay /Zone • Long range radio 7720ULF -XX, Fire /Burg Receiver Module 7845C, 7835CFPK • 5808LST - Wireless Smoke • 4190SN Remote Point Module - Detector two zones • 5809 - Wireless Heat Detector ORDERING VISTA - 128FB Commercial Fire and Partitioned Burglary Alarm Platform 12V Model v128FB - 24 Commercial Fire and Partitioned Burglary Alarm Platform 24V Model Honeywell Security & Custom Electronics 165 Eileen Way, Syosset, NY 11791 www.ademco.com Copyright ©2004 Honeywell International Inc. UVIS12BFBID 1/04 Honeywell ADEMCO VISTA- 128FBN128FB -24 — Supervised by control for Applications Alarm power Commercial Fire and Partitioned Alarm Platform check -in signals Supported by a diverse line of • 12VDC, 1.7A max for each SPECIFICATIONS — Tamper protection for Honeywell initiating devices, the notification (bell) circuit output • transmitters powerful VISTA -128F8 is the ideal Aux. standby power Cabinet dimensions Additional Features — Up to 50 two -wire glass break — Individually assignable up to integrated fire and burglary control • 12VDC, 1A max • 181H x 14.51N X 4.3'D • Notification Appliance Circuits detectors on zone eight eight partitions 9 P for applications where a higher ya wv Environmental (two) • Patented addressable V -Plex — Supports UL864 /NFPA Po level of security is necessary . from at sources 3.4A at 24VDC • Storage temp: -10°C to 70°C — Programmable polling IoopV -Flex technology: approved wireless smoke including medical and professional • Operating temp: — Temporal code compliant — Supports up to 120 two-wire detectors from all sources g mp: 0 to 50 P P pP P buildings, supermarkets, churches Standby time • Humidity: 85% RH — Individually silenceable zones /points • Access control integration and synagogues, office buildings, EMI • Programmable on -board auxiliary — Global polling technology for — Full integration with PassPoint schools, universities, strip malls, • 24 hours with 1A standby load or Meets or exceeds the following relay faster processing • Access Control System larger residences and factory or 60 hours with 205mA max requirements: • SIA false alarm reduction — Increased current draw Complete Gateway in access warehouse environments. standby load using 34AAH • — FCC Part 15, Class B Device features: capacity (128mA) functions Installation battery — FCC Part 68 — Exit Error Logic — Supervised by panel • Event reporting Fusing — Exit Delay Reset — Individually assignable to The VISTA -128F8 alarm system has — IEC EMC Directive y 9 • Local printer of access or VISTA • Battery input, aux. and notification — Cross Zoning partitions, notification circuit been designed to mount both Agency I istln related event gs — Call Waiting Defeat quickly and easily in an attack (bell) circuit outputs are protected . Burglary — Recent Close Report — 4,000 ft capability 9 (bell) output or aux relay • Scheduled uploading of events to using PTC circuit protectors. All without the resistant cabinet It en meets sf all central station outputs are power limited. • UL609 Grade A Local Mercantile • S applicable requirements for UL Supports commercial hardwired, use of shielded cable • Stored events for one call retrieval Main d commercial burglary installations. • Communication EieRrlaL• • Line seize: • Mercantile Safe and Vault and wireless zones — Two -wire smoke detector — Phone mapping by zone — Double Pole • UL611/1610 Grades A, AA, • Hardwired zones: zone /group expansion module response type Primary power: Central Station — Provides nine style B adds two or four zones — 18 VAC@ 72 VA No. 1451 • UL365 Grades A, AA Police — Supports VIP Interactive Phone Quiescent current draw: hardwired zones —Eight zone - Class A and B Voice Module dule ui 300mA Connect — EOLR supervised for Fire and Extender Module — Panel operation during Fire UL burglary installations — One zone supervised Contact download Backup battery 12AH • UL864/NFPA72 Local, Central — Supports N.0 or N.C. sensors Monitor Module — Uploading equipment list to • 12VDC, d bat min to 34AAH max Station and Remote Station — Individually assignable to one • UL Listed wireless expansion central station •Lead acid battery (gel type) • Factory Mutual or all eight partitions — Supports up to 128 wireless — Communication to PassPoint • California State Fire Marshal — Up to 16 two-wire smoke zones using 5881 Receiver via Vista Gateway Module • MEA detectors each zone 1 and 2 (VGM) • UL985 (32 total) I rose I. =I ?, y.�.. AE M �� . 011.1 . . ate• 5 1Nt M �n.: Wotan LI r � .`� �� - . �_ IIvIFxtM 4 i Bx1 _a - 1.,...,n Boer �bn Ec1 Bus 1.....1 ..a 32 &M. nn.m. 1.rw■ .."1 .a N €€ -ear' + sole. ti, , ,, wa war. Nemo « .��� . Manion y„.........:...... 14..••• -Y 5140.0 . et. __� � I 1M1M - � . M••— t€ r ... "°'=" IhmItin Z.I.U. )MSC<:rb il • . American Veterans Security 8301 SW 135 Ave. Beaverton, OR 97008 503.469.9554 January 30, 2005 SW Church of Christ — Fire Plan Wire List Run Number #1 Keypad 24ga solid fire wire 75' #2 Front pull stations 16ga solid fire wire 75' #3 Office Horn/strobes 16ga solid fire wire 95' #4 Stage pull stations 16ga solid fire wire 68' #5 Utility/hall pull stations 16ga solid fire wire 112' #6 Classroom Horn/strobes 16ga solid fire wire 204' Bell Ckt #A 190ft, Alarm Current 1.16ma, 1.93 ohms, veol 24.00 vdrop .01 Bell Ckt #B 408ft, Alarm current 1.97ma, 4.15 ohms, veol 223.99, vdop .03 - How many . Enter powered Standby tarn (aux Alar 1 �� ', ' - - - �, ' ' , AUXILIARY POWERED DEVICES Quantity externally? tarn Current (Aux) Polling Loop ,., 1„,,,, ,,,,,,, . -. 4 volt er Supply Module 1 0 50 100, \��\ \\ 50 100 0 4100SM (no more than one per system) Y 0 0 25 0 \� \�� �� 0 0 0 a2 �� PS24 2 4204: Enter no. of relays used 0 0 40 0 �, 0 0 0 4204CF:Enter no. of relays used \ , , 0 0 0 4285 Voice Module 0 0 160 \ \� 4286 with warning speakers 0 0 220 300 \ \ \ \ \ \ \ \ \\ \00 \ N 0 \� o 0 0 5140DLM Backup Dialer Module 0 0 5 15 0 0 0 5800RP wireless repeater module � 5800TM wireless xmtr module 0 0 1 20 - 0 0 0 5881 EN receiver 0 0 60 \ 0 0 0 5883 hi- security receiver 0 0 80 \\ , .7 0 0 0 7845C Cellular Radio ❑ Current Limited? 0 0 400 &\ �� \\��' 0 0 0 7845CV2 Cell Radio ❑ Current Limited? 0 0 600 � \. 0 0 0 7845i Internet Communicator 0 0 110 L\\„ ' \ . ,„ 0 0 o 997 Ceiling Mount PIR U LED Active? 0 0 12 ,asVVVV 0 0 0 998 Wall Mount PIR IDLED Active? 0 0 13 \ \ \ \ \\ \, 0 0 0 Motion Detctrs (enter quant. & currents) 5 0 0 0 V \ \ � \� \� 0 0 0 Motion Detctrs (enter quant. & currents) 0 0 0 0 \� 0 o 0 Motion Detctrs (enter quant. & currents) 0 0 0 0 t • � �\ ., 0 0 0 Motion Detctrs (enter quant. & currents) 0 0 0 0 � �_. 0 0 0 FSA -8 fire zone annunciator 0 0 35 65 \ ' 0 0 0 FSA -24 fire zone annunciator 0 0 35 130 \\ �� 0, 0 0 UVS 0 0 75 110�1; 0 0 0 \� VA8200 Panel Linking Module 0 0 88 0 ���\ VA8201 Alpha Pager Module 0 0 165 0 � \� >\ \ \ \� 0 0 0 , 0 0 �\\\\ \\ \ \\ ' 0 0 0 Adel Device (enter quant. & currents) 0 0 0 0�� \�� \ 1 ,f,, 0 0 0 POwer Overdraw if highlighted Panel Max Output Exceeded it highlighted grayed -out devices are not supported by selected panel How many Total Enter powered by Standby (aux Alarm Total Polling Standby Tote! External POLLING LOOP DEVICES Quantity 4297? - pwr) Current(Aux) Polling Loop Loop Current Total Alarm Current Cvrrent Required 4101 SN Single Output Relay Module 0 0 \\ ����� \ \\ ? 7 0 k, ,, ,��� \•,: �������\ 419OSN Two Zone SIM 0 0 �\\\\0\\ 000\0\\ \ \ \\ \`00\0\ \ \ \ \ \ \ \ \ \ \ \ \\ 2 0 \ \ \ \ \ \ \0 \ \ \0 \ \ \ \ \\ \\\ \ \ \ \ \ \ \ \ \ \ \ \ \�\\ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ 4190WH 0 0 ��Y\\\00\� \ \\ \0\00 \ \0...���`�'?\ \ \ \\0\ ' 2 0 \ \ \\ 000` \ ..000\\00\\ \\\ �0\\\ 0\���0\\\l\ \ \O\O\\\\� \ \ \ \ \ \ \° 4191 SN -W H 0 0�����.; 0.5 0�����.\ \ \ \����������•I \ \ \ \� \���� \������ 4192CP 0 0 O \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ O \ \ \ \0\ \ \ \ \ \ \ \\ 0.4 0 \ 00\\\ O\\\\\\\ 00\\\\\ 00�\\\\\\\\ O\\\ ` \0 \0\\\0\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ 4192SD Photoelectric Smoke Det. 0 0 \:1. 0.4 0 \\ \\\����� \������ \� 4192SDT 0 o, ��\\\\ 0\\\\\\\\ \ \ \ \ \ \ \ \ \ \ \ \� \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ 0.4 o��0\\\\\\\\ 0\\\\\ 0�`\\\\\\\\\\\\\\\\\ \ \ \ \O \\00\ \ \ \ \ \ \ \ \ \ \ \O \ \ \ \ \, 4193SN Two Zone SIM 0 0 >r \ \ \ \ \�� � \\1������� \\\�� . 1.5 0 • � ������•� \\ \\ \ \\.•.������ ;�\ • 4194 Contact 0 0 \ \ \ \ \ \ \ \ \ \ \ \ \0\ \ \ \\ \..\000 \ \ \ \ \ \ \ \ \�' 1 0 O \ \ \ \ \ �00 \ \ \\ \ \ \ \ \ \ \ \ \ \ \O \ \ \\0 \ \ \ \00 \ \ \0 \O\ \ \ \ \ \ \ \ \ \\\\0 \ \O 4196 0 0 ,k\O\\\ \��� 1 0 • . \\\ \ ��� \ \ \ \\ \ , 7L \\\ \\ \�� 15.5 0 4275EX Dual PIR ■ LED Active? 0 0,� 1 0 \\\ �����\\\\������������� \� \��� 4275EX -SN Dual PIR ❑ LED Active? 0 0 \ \ \ \ \ \\ \� 1 0 �� \� \ \ \�\�� • „\ , ,,\ Z • •��,Igg 4278EX-SN U LED Active' 0 0 �� � \\ \ \�� 1 0�������� �������� 4293SN 0 0 \ \ \ \ \ \ \ \ \ \ \ \�\ \0�\ \\ \ \ \\\\\ \ \\� 1 0 \\\\\\\\ 0\\\\\\\\\ O\\\\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \` O \ \ \ \ \ \ \ \ \ \O\ \ \ \ \ \ \ \ \ \ \0\ 4939SN WH /BR/GY Surf Mt. Cntct. 0 0 \ "1, \. \l 1 0 , ��������� ��\�����\\\\��� ������ \,.��\ 4944SN Recessed Contact 0 0 ������� \������ \�\ 1 0 ���������� \�������� \���� ��� 4945SN -WH 0 0 \ �Q \��� 0.5 0 ���\\\ ����\\� � \ '\ \�������\���\ 4959SN Overhead Door Contact 0 0 ��� \ \ \ \ „� 0.5 0 ������ \ �� \u \�� \��������������������\ 5192SD Smoke Detector 0 0 \ \ \ \u \��� \���� �� \���� \ ;, 2.8 0 ��������\ �� ���������� � \� 5192SDT Smoke Detector with Heat 0 0 ' , 2.8 0 N: \''\ \\\\\\ 998MX PIR • LED Active? 0 0 \ \\ \ \l �\\� ::. 1 0 \\\\\\\\\\\���� ���� ������ \ \ \ \ \ \ \���������� FG- 1625SN Glass Break Detector 0 0 `��\ � \ 1 0 k� �� 1 , ����� „���� • ���\ • Quest226OSN 0 0 00 \0 \ \ \0\� \ \ \ O O \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ 6 0 \\\\\\ 0\ 0\\\\\\\ \ \ \ \0\ \ \ \ \ \ \ \ \ \ \ \ \ \ \0\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \0 \ \ \ \ \ \ \ \ \ \ \\ . . Vistakey 0 0� \��� 2 0 ���\ ���� \\� \ \ \O \�������������� \����� . Add'! VPlex (enter qnt y &current) 0 0 �� \����� ��������\ 0 0 ��\����\\\\\ 0�\\\\\�\\\��\ \ \�� \ \ \ \ \ \\ Add'! Vpiex (enter qnt y & current) 0 0 \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \O \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \`r 0 0 \\\\\\\\\\\\\\\\\, ���\\\O \ \ \ \ \ \ \ \0 \ \ \ \ \ \ \ \ \ \ \ \\00 O\ \ \ \O \ \ \ \ \O\ \ \ \ \ \ \ \ \ \ \ \ \\ _ - w ®€ "r e i-,:' ;';',, - Otti,hgV4Kgiverdraw if highlighted, E 4287 „ # „:. P. t401 44g_ - htighted C O N V E N T I O N A L D E T E C T I O N � Series Photoelectric �� SYSTEM Smoke Detectors �� SENSOR Models Available Two -Wire Models 2W -B 2 -wire standard 2WT -B 2 -wire standard with thermal Four -Wire Models 4W -B 4 -wire standard • • 4WT -B 4 -wire standard with thermal Accessories 2W -MOD2 2 -wire loop test /maintenance module - x; SENS -RDR Sensitivity reader Removal/replacement tool RT A77-AB2 Retrofit adapter bracket = - i Product Overview Plug -in detector line — mounting base System Sensor's i " series smoke detectors represent a significant advancement in included conventional detection. The i family is founded on three principles: Installation ease, Intelligence, and Instant inspection. Large wire entry port Installation ease. The i line redefines installation ease with its plug -in design. In - line terminals with SEMS screws This allows an installer to pre -wire the bases included with the heads. The large Mounts to octagonal and single - gang wire entry port and in -line terminals provide ample room for neatly routingthe backboxes, 4 - square backboxes, or wiring inside the base. The base accommodates a variety of back box mount- direct to ceiling ing methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug -in to the base with a simple Stop -Drop 'N Lock Stop - Drop 'N Lock" attachment to base action. Removable detector cover and chamber Intelligence. i detectors offer a number of intelligent features to simplify for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are standard with the i line, to minimize nuisance alarms. When connected to the Built - in remote maintenance signaling 2W -MOD2 loop test/maintenance module, or a panel equipped with the i protocol, 2 -wire i detectors are capable of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleaning. This signal is indicated via an LED algorithms located at the module and the panel. To read the sensitivity of i detectors, the SENS -RDR is a wireless device that displays the sensitivity in terms of percent Simplified sensitivity measurement per foot obscuration. Wide angle, dual color LED indication Instant inspection. The i series provides wide angle red and green LED indica- tors for instant inspection of the detector condition, indicating: normal standby, Loop testing via EZ Walk feature out -of- sensitivity, alarm, or freeze trouble conditions. When connected to the Built - in test switch 2W -MOD2 loop test/maintenance module or a panel with the i protocol, the EZ Walk loop test feature is available on 2 -wire i detectors. This feature verifies the initiating loop wiring by providing LED status indication at each ® ® � _ MEA MSFM LISTED approved approved detector. 1 7 5911 3011446 7272 - 1209:210 290-01-E 2093 Architect /Engineer Specifications Smoke detector shall be a System Sensor with a plaster ring, or direct mount to the The detector shal 1 provide dual color LED i Series model number , listed to ceiling using drywall anchors. Wiring con- indication which blinks to indicate power Underwriters Laboratories UL 268 for Fire nections shall be made by means of SJMS up, normal standby, out of sensitivity, , Protection Signaling Systems. The detector screws. The detector shall allow pre - wiring alarm, and freeze trouble (model 2WT -B : shall be a photoelectric type (model 2W -B, of the base and the head shall be a plug- 4WT-B) conditions. When used in conjurtc, 4W -B) or a combination photoelectric/ in type. The detector shall have a nomi- tion with the 2W-MOD2 module, 2 -wire thermal (model 2WT-B, 4WT-B) with Cher- nal sensitivity of 2.5% per foot nominal models shall include a maintenance signal mal sensor rated at 135 °F (57.2 °C). The as measured in the UL smoke box. The to indicate the need for maintenance at the detector shall include a mounting base for detector shall be capable of automatically alarm control panel, and shall provide a mounting to 31/2-inch and 4 -inch octagonal, adjusting its sensitivity by means of drift loop testing capability to verify the circuit single gang, and 4 -inch square back boxes compensation and smoothing algorithms. without testing each detector individually. Electrical Specifications Operating Voltage Standby Current Peak Standby Current • Nominal: 12/24V non - polarized --)2-wire: 50 pA maximum average 2 -wire: 100 pA Min.: 8.5V 4-wire: 50 pA maximum average 4 -wire: n/a Max.: 35V Maximum Alarm Current Alarm Contact Ratings Maximum Ripple Voltage ) 2-wire: 130 mA limited by control panel 2 -wire: n/a 30% peak to peak of applied voltage 4 -wire: 20 mA @12V, 23mA @ 24V 4 -wire: 0.5 A @ 30V AC /DC LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds i,``. Freeze trouble off Blink every 10 seconds Alarm off Solid Physical Specifications Operating Temperature Range Sensitivity Mounting 2W -B and 4W -B: 32 °F -120 °F (0 °C -49 ° C) 2.5 % /ft. nominal 3%-inch octagonal back box 2WT -B and 4WT -B: 32 °F -100 °F (0 °C- 37.8 °C) Input Terminals 4 -inch octagonal back box Single gang back box Operating Humidity Range 14 -22 AWG 4 -inch square back box with a plaster ring 0 to 95% RH non - condensing Direct mount to ceiling Dimensions (including base) Thermal Sensor 5.3 inches (127 mm) diameter • 135 °F (57.2 °C) fixed 2.0 inches (51 mm) height . Freeze Trouble Weight 2WT -B and 4WT -B only: 41 °F (5 °C) 6.3 oz. (178 grams) Ordering Information , Model Thermal Wiring Alarm Current 2W -B No 2 -wire 130 mA max. limited by control panel - >2WT -B Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA @ 12V, 23mA @ 24V 4WT -B Yes 4 -wire 20 mA @ 12V, 23mA @ 24V Model Description 2W -MOD2 2 -wire loop test / maintenance module SENS -RDR Sensitivity reader RT Removal / replacement tool A77 -AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor - Far East System Sensor - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800 /SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 ® 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0318-005.8/04•#1280 • Y l , 11AEA 1 ADA_ ...SY6TEM5 I il .'.._ ..._.. Helping People Take ActionsTM Description: Series MPS Wheelock Series MPS non -coded Manual Pull Manual Pull Stations Stations are constructed of high quality, die -cast metal for long lasting performance and may be mounted on a single gang backbox. Available in either single or dual action configurations for indoor or outdoor use with SPST contacts and �— .�.t�i � terminal strip connections. The normally open ;FIRE E i I contact will close when the pull station is activated F+ 4"` FIRE and is rated for 1 amp @ 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The single action explosion -proof model Series'�� s MPS -400X is UL Listed and Factory Mutual approved for use in Class I, Groups 8, C and D; Class II, Groups E, F and G; and Class III hazardous environments. It also has a marine rating and is WheebCk approved for NEMA -4X applications. All models are painted red with raised white MPS -100 M PS -400X lettering and a locking mechanism to prevent MPS -200 unauthorized reset. Features: Operation: • Approvals Include: UL Standard, Factory The Series MPS is operated by pulling the handle on the Mutual (FM), California State Fire Marshal front of the station as far down as it will go, at which point (CSFM) and New York City (MEA) the handle locks into place and is easily visible from up to • Single or Dual Action 50 feet. The handle is reset by opening the station with a= ' • Key Reset key, placing the handle in the normal upright position and • Terminal Strip Connections relocking the station. • Corrosion resistant, gold plated SPST contacts On dual action models (not shown), the push bar rotates` • Mounts on single gang backbox inward allowing the Pull handle to be grasped in a one • Surface and Weatherproof backboxes available handed motion. • Plastic breakrod • High -gloss red enamel finish with raised white lettering Specification and Ordering Information: Model Order Description Mounting Number Code Options MPS -100 8400 SPST, Single Action, Terminals, Key Reset MPS -ISB, MPS -WP • MPS -200" 8401 SPST, Double Action, Terminals, Key Reset MPS -ISB, MPS -WP MPS -300" 8402 DPST, Single Action, Terminals, Key Reset MPS -ISB, MPS -WP • ,t MPS -400X 8403 Explosion Proof, Single Action, Key Reset (Backbox provided) MPS -ISB 8404 Interior Surface Backbox Red MPS -WP 8405 Weatherproof Backbox with Gasket Assembly MPS -RODS 8406 Scored Acrylic Breakrods (dozen) • Consult Customer Service for Availability Copyright 2004 Wheelock, Inc. All rights reserved. heeloUc • M EA ADA _•• • Ilk Helping People Take Actions" SERIES NS SINGLE & MULTI - CANDELA HORN STROBE APPLIANCES SERIES NH HORNS Description F: _ F The Series NS Horn Strobe Appliances will satisfy virtually E R all requirements for indoor, wall mount applications. The Series NH Horn and the horn portion of the Series Series NH Series NS NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. t _ : * . , t"' Strobe options include 1575cd or Wheelock's patented Multi - Candela strobe with field selectable candela settings of 15/30/75/110cd. Multi- Candela Indicator These versatile Horn Strobe Appliances can be (bottom of Strobe Lens) synchronized using the Wheelock SM, DSM Sync Modules or the PS- 12/24 -8CP and PS- 12/24 -8MP Power Supplies with Wheelock's patented Sync Protocol. Features Additionally, the audible may be silenced while Approvals include: UL Standard 1971, UL Standard 464, maintaining strobe activation. New York City (MEA), California State Fire Marshal All models of the Series NS and NH are designed for (CSFM) and Factory Mutual (FM) Pending: Chicago maximum performance, reliability and cost - effectiveness (BFP) • while meeting or exceeding the latest requirements of ADA/NFPA/UFC /ANSI compliant NFPA 72 /ANSI 117.1 /UFC and UL Standards 1971 and • Complies with OSHA 29, Part 1910.165 464 as well as meeting ADA requirements concerning • Field Selectable Candela Settings 15/30/75/110cd photosensitive epilepsy. (24 VDC Multi - Candela models) or 1575cd in 12 or 24 VDC • Wheelock's patented 2 -Wire Series NS Horn Strobes and Selectable Continuous Horn or Temporal (Code 3) Series NH Horns offer more features with low current draw. • 2 Selectable dBA settings of 90 and 95 dBA in both tones • Patented Universal Mounting Plate • 12 and 24 VDC models with UL "Regulated Voltage" using filtered DC or unfiltered VRMS input voltage • Wall Mount • NH horn is selectable 12 or 24 VDC in 1 unit • The strobes can be synchronized using Wheelock's sync modules or power supplies with built in Sync Protocol • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wires Copyright 2003 Wheelock Inc. All rights reserved. • NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. • A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL Standard 1971 Table 2: dBA Ratings for Series NS /NH Horn In put Regulated Reverberant dBA p Voltage Strobe Description Volume @ 10ft per UL 464 Anechoic dBA@ 10 ft Model Voltage Range Candela (CD) p VDC VDC /FWR 12VDC 24VDC 12VDC 24VDC NS -24MCW 24 16.0 - 33.0 15/30/75/110 Continuous High 83 87 89 95 Horn Low 76 81 84 90 NS- 241575W 24 16.0 - 33.0 15 (75 on Axis) NS- 121575W 12 8.0 - 17.5 15 (75 on Axis) Code 3 High 79 82 89 95 Horn Low 72 76 84 l 90 - 7 1 ". Table 3: Average RMS Current* Audible Wall Mount Audible Strobe Models Series NS /NH NH -12/24 NS- 241575W NS -24MCW 24 VDC @24VDC 15/75cd 15cd 30cd 75cd 110cd 24VDC 0.035 0.082 0.061 0.085 0.129 0.167 High (95) dBA UL max* 0.044 0.104 0.074 0.107 0.184 0.244 24VDC 0.014 0.067 0.049 0.072 0.117 0.154 Low (90) dBA UL max* 0.018 0.096 0.066 0.101 0.177 0.232 Audible Wall Mount Series NS /NH NH -12/24 Aud /Strobe * RMS current ratings are per UL average RMS • 12VDC method. UL max current rating is the maximum @12V NS- 121575W RMS current within the listed voltage range (16 -33v 12 VDC 0.016 0.160 for 24v units). For strobes the UL max current is High (89) dBA usually at the minimum listed voltage (16v for 24v UL max* 0.021 0.262 units). For audibles the max current is usually at i 12VDC 0.010 0.155 the maximum listed voltage (33v for 24v units). For Low (84) dBA unfiltered FWR ratings, see installation instructions. UL max* 0.012 0.257 • • CORPORATE OFFICE & WAREHOUSE St. 2081 Louis, Craig Road annece, St. Louis, Missoouri 63146 (800) 325 -3936 Fax: (800) 768 -8377 A (P t�UTifR 6a Local: (314) 878 -4321 Www.amscco- kai.com /sa lcsia pottersign al.com MBA Series Indoor /Outdoor Fire Alarm DC Motor Driven Bells Description_ AMSECO's MBA Series Indoor /Outdoor bells utilize a specially designed gong, that gives out a loud mechanical resonant tone. This improvement is designed to make the whole series more effective and provide performance and dependability at a low current consumption. The bell design incorporates a micro -motor with built -in varistor suppression element, to reduce RFI and EMI interference found in today's mgri highly integrated microprocessor driven control panels. The U(. © MEA terminal design makes it convenient when wiring or trouble- shooting. The design features as a result saves you time and APPROVED iii provides a more effective installation for maximum performance. The MBA series bells are made available in 6 ", 8" and 10" gong size and are painted red to enhance its Features:_ appearance and provide a long durability. " Indoor / Outdoor motor driven design " UL Listed for fire protective service * Polarized models with wide listed voltage range Application: using filtered DC or unfiltered FWR input voltage. The MBA series bells is recommended for use Indoors or " Terminals for fast in /out field wiring. Outdoors in areas such as: schools, corridors, apartments, * High sound dB output with low current draw. office buildings, hotels, and any other application where *Built-in trim plate for a clean flush mount installation. effective audible warning is required and approved by *All models mount to a 4" square back box. Federal, State, or local authority having jurisdiction. *A complete range of gong sizes 6 ", 8 ", and 10 ". " Input terminals for field wiring using AWG 12 to 18. RFI and EMI noise suppression element built -in. Gong Size 6, 8, and 10 inch: Red color only. 10" Wiri ng : $" Control To Next Device or Panel End -Of Line - Resistor 6 „ L ,■ fl 1, WARNING: J Conductor Size (AWG), Lenght and capacity should be taken into consideration prior to design and installation of these products, particularly in retrofit installations. Ordering Information: Rated Rated Operating Indoor Operating Model Gong Voltage Current Range UL Rating Measurement Temperature Number Size ( VDC) ( Amps) ( VDC) (dBA) (dBA) Range MBA -6 -24 61 24 0.012 I 16 - 33 83 86 - 89 -31 F - 150 F MBA -8 -24 81 24 0.025 16 - 33 83 90 - 93 (35 C - 66. C ) lip MBA-10-24 10" 24 0.023 16 - 33 85 92 - 94 . Engineering Specifications: - I MBA-Series or equivalent device. The Bell s The alarm indicating appliance shall be AMSECO mode MBA Se es shall be listed for Indoor and q h Outdoor under UL Standard and shall be approved for fire protective service. The typical dB output shall be 87 -- 91dB. The signaling device shall operate on 24VDC from a non -coded regulated DC supply or full -wave rectified, unfiltered supply. The signaling device shall be designed to produce an indoor dB signal output of 86 - 94 with continuously applied minimum voltage. The signaling device shall be capable of mounting to a 4" x 4" x 1 -1/2" standard back box. Specifications:. Rated Current I Sound Output 16VDC 24VDC 33VDC Model Gong uL 1 Typical UL ULC Typical UL Typical Number Size DC mA. FWR mA. dB dB mA. AR dB dB dB DC i mA. FWR mA. dB dB MBA -6-24 61 7.0 8.0 77 1 81 12.1 12.4 83 85 87 13.5 24.2 85 89 MBA - - 24 81 13.0 15.6 76 j 80 0 30.6 83 85 87 40.0 43.9 86 90 MBA - 10 - 24 10" 11.0 13.6 79 , 83 23. ( 26.8 85 85 91 34.0 46.0 87 91 Indoor /Outdoor Measurement Sound level in the Indoor /outdoor installation may vary depending upon the spaces. Typical dB measurements with conventional sound level meters will be significantly higher in actual installations. UL and ULC dB measurement method are different. Horizontal Dispersion: Vertical Dispersion: Angle _ 6 "dB /m 8 "dB /m 10 "dR /m Angle 6 "dB/m i 8 "dB/m 10 "dB/rrt -90 -5.1 0.3 3.4 -75 -4.3 0.8 4.8 9O° -60 -1.9 1.8 4.5 -45 1.4 0.8 1.3 90°4 -30 -3.4 -0.6 -1.0 -15 -4.5 -2.1 0.0 tAk 1 0 0.0 0.0 0.0 0,4,.... 15 -4.0 -0.9 0.8 30 -3.0 -3.3 -1.3 0° W 4 5 -1.5 -0.4 1.9 60 -2.9 1.8 2.9 �° 75 -2.1 1.8 2.9 -9 90 -1.8 -1.0 2.9 Dimensions: Inches (mm) 0 10 (77)2 ��� (� 0 (250) _ rn 92 c (g) ir .*---(T 1 c c 200 3 ° g n O °� WI 1 6 N 0 ' (150) N st Mal q List = .r .Il'J �� 3 -3/8 (60.5) - _ 3 29) 2.382 (60.5) (85.7) Mounting Holes 3.374 (85.71 =mum Mounting Options: 2 -3/8 (60.5) 4.724 120 Single gang backbox 4" x 4" x 1 -1/2° backbox BBX-4 weather -proof backbox t I 4 1:1 r e r P: % - °- ._,° 5 \!� ! i / aI ( \ is, 4 IS . , s , 14 9 i • Due to continuous development of our product line, specifications ere subject to change without notice. MBA 10/04