Loading...
Specifications Fire Systems West, Inc, 600 SE Maritime Ave. Suite 300 Vancouver, WA 98661 CITY O TIGARD (360) 693 -9906 Approved .5 1,1 [ - Conditionally Approved........,..... [ I See Letter to: Follow......... [ I Atta L ......�� P mit ber .0 dt_Awira *17 � 'ri Date: Coro'!a • • REVIEWED FOR CODE COMPLIANCE OFFICE COPY FIRE SPRINKLER t. TENANT IMPROVEMENT SUBMITTAL PLAZA WEST, 5 FLOOR, SUITE 500 9600 SW OAK STREET TIGARD, OR 97223 10/3/11 FSW JOB NO. Job# 271118 INDEX °ROJECT: PLAZA WEST, 5TH FLOOR, SUITE 500 TENANT IMPROVEMENT Number Description I Manufacturer I Model No. 1 Sprinkler Head, RA1414 Reliable F1 FR `(, 2 Outlet coupling Victaulic Style 72 3 Pipe Nap Steel Sch 10/40 4 Flex Connection AquaFlex AQU i 5 Ring Hanger Afcon 300 6 Sammy Verical for Concrete Sammy Screw Vertical r� Bulletin 014 Rev G CO h am. ` �� : Y T:: § .`� ' -ad.. L. (:'a:.. _ _. .- ... ...._ _.v+,' 3 y Y� ; C • Model F1FR56 Series Quick Response Standard Spray ' 0 Model Fl FR56 Sprinkler Types , : ,.. Standard Upright " �4; z ., Standard Pendent V � Conventional ° f, ' Vertical Sidewall`' "" .k' Horizontal Sidewall a ,w' - Model Fl FR56 Recessed Sprinkler Types Standard Pendent /F1 /F2 /FP Upright Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent jot d Listing & Approvals "' 4 -› 1 Underwriters Laboratories Inc and Certified for Canada (cULus). ', ,1 2 Factory Mutual Approvals (FM) Conventional Horizontal Sidewall 3 Loss Prevention Council (LPCB, UK) 4 VdS Schadenverhutung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) l l �, ,, Quick Response Sprinkler t. , ',., - CPI - - ;'"°:, TA, Product Description Reliable Models F1FR56 Series Sprinklers are quick re- a'14;m . ; sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative Recessed Recessed sprinkler. Pendent/F1/F2 Horizontal Sidewall The Models F1FR56 Series Recessed automatic span- :, , , < ;, .µ,; klers utilize a 3.0 mm frangible glass bulb These span- k klers have demonstrated response times in laboratory tests K e which are five to ten times faster than standard response ���� �, r� � a , sprinklers. This quick response enables the Model F1FR56 f �2A., x� ., i ,. � 4. Series sprinklers to apply water to a fire much faster than I.,:� .-2 �a standard sprinklers of the same temperature rating ' "'. ,•: +�:: 1 �� "'` 4' The glass bulb consists of an accurately controlled amount .-r_ •• ... s ; . „:'. of special fluid hermetically sealed inside a precisely manu- Concealed Recessed i' factured glass capsule. This glass bulb is specially con- Pendent Pendent /FP structed to provide fast thermal response At normal temperatures, the glass bulb contains the fluid Application in both the liquid and vapor phases The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems Wet, Dry, Deluge or Preaction. Care must be expands, forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec- uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- opening the waterway and allowing the deflector to distrib sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as specified in NFPA 13 Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1 FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Identification Number Nominal Thread Nominal K Factor Sprinkler Approval (SIN) Orifice Size Height Organization US Metric Upright Pendent Standard - Upright (SSU) and pendent Deflectors Marked to Indicate Position 1 /2 ' (15mm) Y2" NPT(R' /z) 56 80 2 25" (57mm) 1, 2, 3, 4 RA1425 RA1414 h"' Conventional- Install in Upright or Pendent Position 15mm 1 /2" NPT(R' /2) 56 80 57mm 3,4 RA1475 cULus listed corrosion resistant (Polyester coated) sprinkler. 2) Polyester coated FM approved sprinkler '3 x a Upright Pendent Conventional Model F1 FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) Y2" (15mm) Y2' NPT(R/2) 5 6 80 2 25' (57mm) RA1414 Refer to escutcheon data table for approvals and dimensions f 2 5/8 ° D/A [68 7mm] 2 HOLE ON HOLE IN CEILING s /IS z 5 /I6 ° o/A [587mm] `/) -- =1 L — _ = J /? 72222' I I 1" X 1/2" REDUCER /Ur — III L..LLI -R i UNTIL IIGI1 r. ✓dNSr sn.cINILES 1 1 I I NRENCO 50 5 . \ // \\ // L/!L /_//J � �— J7LU I7CC E7 ITONC EO ('l CEILING L cErumc 5ruEN5roN I' N ®�d� �INII a FACE OF FITTING " TO FACE OF CEILING 4r) Illpil III�II 4 DIMENSION (r � � � I � [[ J2mm) J !' 111 I— ADJUSTMENT(r1 t � - •A •• ' /- = 2' VIA � r , CC( I m 1�22. -i „) (I) REILR 20 Cl & 17 'sfu2Clfl On' 1021 TOGLE FOR «000'.OL5 AND O02EI,5r00''5 (I) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS Model F1FR56 /F1 or F2 Model F1FR56 /FP 2. (A r.. Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Nominal Sprinkler Approval Orifice Thread Size Identification Height Organizations , US Metric g Numbers (SIN) /2" (15mm) 1/2" NPT (R1/2) 5 6 8 0 2 25" (57mm) 1,2,3,4 RA1485 15mm Y2" NPT (R1/2) 5 6 8 0 2.25" (57mm) 4 0) LPC Approval is for pendent position only I 21 cULus Listed corrosion resistant (Polyester coated) sprinkler Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) '' Upright 4" (102mm) - 12" (305mm) c P� Pendent 4" (102mm) 12' (305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification SIN US Metric Light Hazard Ordinary Numbers Hazard (SIN) 1/2" (15mm) 1/2" NPT (R1/2) 5 6 80 2 63" (67mm) 1,2 1 RA1435 ") cULus Listed corrosion resistant (Polyester coated) sprinkler FACE OF FITTING (1) _ s TO FACE OF CEILING S D IMENSION _ - 1 1/4" MIN • t - 2 7/4 (37 8mm] HOLE DIA 4"-12" (2) (57 2mm] y ( 3 78 m] (107 6mm -304 8mm] ,..':` • l z . CEILING TO J ' X J 2 REDUCER & DEFLECTOR 1" � l P1 1 Horizontal Sidewall / 7 7 5 16 "' DlA �/ �_ (49 2m n II��II �IIII �' 2 27/32" D.A (72 2mm] �" I ' TURN COLLAR UNTIL � TIGHT AGAINST . SPRINKLER `\ WRENCH BOSS LI —_I 1 -f- ADJUSTMENT (1) 13FG03B (7) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS (2) FM APPROVED FOR 4 - 6 ' (101 6MM - 152 4MM] CEILING TO DEFLECTOR Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K" Factor Temp. Rating Max. Sprinkler Nominal Thread Model Ambient Bulb Approvals Identification Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN) ' /2" (15mm) 56 j 80 1/2" NPT F1FR 135 °F /57 °C 135 °F /57 °C 100 °F /38 °C Orange 1 RA1414 1/2" (15mm) 5 6 80 h" NPT F1FR 155 °F /68 °C 135 °F /57 °C 100 °F /38 °C Red 1, 4 (12 RA1414 1/2" (15mm) 5 6 80 1 /2" NPT F1FR 175 °F /79 °C 165 °F /74 °C 100 °F /38 °C Yellow 1 RA1414 1 /2" (15mm) 5 6 80 /2" NPT F1FR 200"F/93°C 165 °F /74 °C 150 °F /65 °C Green 1 RA1414 ii For VdS only = 155 °F /68 °C Norbulb and 1/2" [12,7mm] adjustment. 7 " x ,/2" REDVCING TOE ON El L2v 1 , _ _ / 1/2' Rr= ouuA'S - � 1T 1 T/± ON TIEavI _ H f f i', -- 11 It -- —�) l �- - -- - i i _ -,rS,- - - - ' i L -- - 2 5/N DMA m – – �.' III / L 5/i 5 Cl/ – h. - -_ -- , :',_%,L IN CEILN!, – - '--'– 2 './8 DIA 5//i6"" Pi _ ' � FI01F_ IN CEiuNO rat �J 41' ti - ti i � i 1 /2' MAX cur> �_�° ��-- � — r – ; 1, „ _ . ' `' ° "�� FACE OF OTTwC. r ��i�I ,:? J i ', k , i /2_' Na, /� t .j i F ' , iG FACE CO CEILING - -- – -{, �' FACC OF FIRING % — = C -T7. 0/2221ION �, ;' a � – – _, FO FACE OF CFil INC uNG "� �_, �r 1..I1.4EN=ION l — == i / COVER 'OJUS I, ✓t,VT �� �� CO ✓Lft , „,j TM[NT �V d r / T couEFZ FU rs / covEr HA fC — SSEHO, r SsCM Lt _ 3 5 /iC" OM -- – / r 5 /!6 LEA SPRINKLER / 5P�NNLER ■ ■ 7 /2 ADJUSTMENT i 5ji6 ADJUSTMENT Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- Important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination ed by the installation of the attractive, low profile, 135 °F Installation (57 °C) or 165 °F (74 °C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly The cover plate and sprinkler cup as- as specified in NFPA 13 Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement A choice of two cover The Model F1FR56 Recessed Quick Response Sprin- plate assemblies provide either 1/2" (13mm) or 5 /16" (8mm) klers are to be installed as shown. The Model Fl or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers The use positive pressure in the space above of any other recessed escutcheon will void all approvals After a 2 (67mm) diameter hole is cut in the cell and negate all warranties, ing, the sprinkler is easily installed with the Model RC1 When installing Model F1FR56 Sprinklers, use the Mod- Wrench A Teflon* based thread sealant should be el D Sprinkler Wrench Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting When NOTE: A leak tight 1 /2" NPT (R112) sprinkler joint can inserting or removing the wrench from the sprinkler /cup be obtained with a torque of 8 -18 ft-lbs (10,8 - 24,4 N -m) assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler DO NOT WRENCH ON ANY OTHER PART torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER The cover plate is then pushed klers onto the cup. Final adjustment is made by hand turning The Model F1FR56/ CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact 1 /2" orifice, 1 /2" NPT (R1/2), 135 °F (57 °C), 155 °F (68 °C), with the ceiling. Cover plate removal requires turning in 175 °F (79 °C) or 200 °F (93 °C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. v „1 I After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above Conventional Concealed cover plate /cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate /cup assembly with the Model F1FR56 Horizontal Sidewall Pendent Spi inkier or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will p -, void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation REMOVE THIS PROTECTION AT THE TIME Finishes t'> THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION Removal of the protectors before this Standard Finishes Sprinkler Escutcheon Cover plate time may leave the bulb vulnerable to damage. RASCO Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place REMOVE PROTECTORS BY UNDOING THE Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated (4)(5) White Painted THE PROTECTORS. Special Application Finishes Sprinkler I Escutcheon Cover plate Temperature Ratings Bright Brass (3) Bright Brass Bright Brass Sprinkler z Black Plated Black Plated Satin Max. Ambient Black Paint Black Paint Off White Classification Temperature Temp. Bulb Color °C °F p' Off White i' Off White Black Paint Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100 °F (38 °C) Orange iii Other finishes and colors are available on special order. i Ordinary 68 155 100 °F (38 °C) Red Consult the factory for details I Intermediate 79 175 150 °F (66 °C) Yellow (2) cULus Listed only Intermediate 93 200 150 °F (66 °C) Green ,3) 200 °F (93 °C) maximum High (1) 141 286 225 °F (107 °C) Blue (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 1 ' ) Not available for recessed sprinklers (HSW). RA1485(VSW), RA1425 (Upright) and RA1414 (Pendent) in standard black or white Escutcheon Data (1) 15) FM Approvals finish as "Polyester coated" applies to SIN Number Face of Fitting to RA1414 (Pendent) in standard black or white Escutcheon Approvals Adjustment Dimension Ceiling or Wall Dimension Ordering Information Max Recess 11/2" (381mm) S he " - /2 Specify: 1 F1 1,3.4 Min Recess 3 /4 "(191mm) _(5mm -24mmL 1 Sprinkler Model Max Recess 1 VI (38.1mm) She " -17he' 2. Sprinkler Type F2 1, 2, 3, 4 Min Recess 1 "(25mm) (5mm -17mm) p yp 3. Orifice Size FPPushon/ Max Recessed 7 /16 "(11mm) 1 (381mm) Thread-off Min Min Recessed 15 /16(24mm) 1 "(25.4mm) 4. Deflector Type ") SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for "light 5. Temperature Rating hazard" only, while FM limits use for same hazard with F2 escutcheon only 6. Sprinkler Finish 7 Escutcheon Type Maintenance 8 Escutcheon Finish (where applicable) The Models F1FR56 and F1FR56 Recessed Sprinklers 9. Cover plate Model should be inspected quarterly and the sprinkler system 10 Cover plate Thread size i. maintained in accordance with NFPA 25. Do not clean 11 Cover plate Temperature sprinklers with soap and water, ammonia or any other 12. Cover plate Adjustment cleaning fluids Remove dust by using a soft brush or 13. Cover plate Finish gentle vacuuming Remove any sprinkler which has been painted (other than factory applied) or damaged Note: When Model F1FR56 Recessed sprinklers are ordered, the sprin- in any way A stock of spare sprinklers should be main- klers and escutcheons are packaged separately tained to allow quick replacement of damaged or oper- ated sprinklers Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. 5. Reliable...For Complete ProtectiOn Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by 41 The Reliable Automatic Sprinkler Co., Inc Recycled Reliable° (800) 431 - 1588 Sales Offices P (800) 848 - 6051 Sales Fax Revision lines indicate updated or new data (914) 829 -2042 Corporate Offices • §_' www reliablesprinkler corn Internet Address EG Printed U S A 08 /11 P/N 9999970300 t �\ ?�vr �.�m .. �u� ,... x aiw � x f & .... -.mod, _ � ® U� FM ... I LP'^i gl ,,, Mechanical-T Bolted Branch Outlets 0 ® [VdS ) SEE VICTAULIC PUBLICATION 10 01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical -T Outlet provides a direct branch connection at any location a hole can be cut in pipe 1 he hole is cut oversize to receive a "holefinder" locating collar which secures 4- the outlet in position per rnanently A pressure responsive gasket seals on the pipe 0 D Cross type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections NOTE Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet Specify choice on order Units are supplied painted with plated bolts Galvanized hous- PATENTED ings are available, supplied with plated bolts All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe They may also be used on high density polyethylene or poly butylene (HDPE) pipe Pressure ratings on HDPE are dependent on the pipe rating Contact Victaulic for ratings on other pipe Style 920 and 92ON are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface Additionally, the Vic -Tap H° hole cutting tool which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical -T in conjunction with the Series 726 Vic Ball Valve to create the Style 931 Vic -Tap II Mechanical -T unit See page 8 for further information MATERIAL SPECIFICATIONS Housing /Coating: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, with orange enamel coating Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request • Optional: Hot dipped galvanized Gasket: (Specify choice *) • Grade "E" EPDM EPDM (Green color code) Temperature range —30 °F to +230 °F / -34 °C to +110 °C Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services UL Classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +180 °F / +82 °C NOT RECOMMENDED FOR PETROLEUM SERVICES • Grade "T" nitrlle Nitrite (Orange color code) Temperature range —20 °F to +180 °F / -29 °C to +82 °C Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range Not recommended for hot water services over +150 °F / +66 °C or for hot dry air over +140 °F / +60 ° C *Services listed are General Service Recommendations only It should be noted that there are services for which these gaskets are not recommended Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended Bolts /Nuts: Heat treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183 JOB /OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC 0 A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED iCtau�lC ...... REV_L 11.02_1 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS . . .; a ri 4 i„ t. x h p,. L , a _� + e _ Approx ��' F ° `Size - ._ No. Pressure@ ° ° Dimensions = < * x ' Weight Each` '14C-144 z �� �. ice' ». 4�,T.<,:av: E.._ a`S :.G' `.: 1 v, ` �'� i :� � � �� � � �a � ,�. t . `�w . , , Y ,- .— G —,- 7 4 1 :h ki ' ,, 4,S e r. w � Via.. '_ 2 Y (1 '5)' _ 500 1 50 2 00 2 53 1 61 5 35 2 75 3 1 V � ` 50 x 1 5 92oN 3450 381 51 64 41 136 70 15 m �A� � �i� � % (a) ❑ 92oN 500 1 50 1 97 2 53 1 5 35 2 75 3 1 _ �_ ,� 20 3450 381 50 6 136 70 15 (.3)a 500 150 185 253 161 535 275 30 — W ��� 25 92oN 3 381 47 6 �1 1 70 1 1 1/4 (a) r a' 920N 500 1 75 2 05 2 75 3 00 1 61 5 35 3 00 3 5 3 2 GROOVED OUTLET 32 3450 44 5 52 70 76 41 136 76 17 15 115 (a)ta 920N 500 175 203 275 312 161 535 325 36 32 40 3450 44 5 52 70 79 11 136 83 1 7 1 5 r Y a . 7 > 2'/ % (a) 5a 500 1 50 2 21 2 74 1 82 S 64 Z 75 3 0 A 65 x 15 920N 3450 381 56 70 46 143 70 1 I 35 (a) § a 920N 500 1 50 2 18 274 _ 1 82 5 64 2 75 3 0 V z . �� ` Nix jai 20 3 331 55 70 46 143 70 14 j r 4. 1 (a) §❑ 920N 500 1 50 2 06 2 7 1 82 5 64 2 75 2 9 — - ' - }t 25 3 381 52 70 46 143 70 1 o / W pli l 3 (a) ❑ 920N 500 1 75 2 30 3 00 3 25 1 82 6 29 3 00 3 5 3 2 • 32 3450 44 5 58 76 83 46 160 76 1 7 1 5 FEMALE THREADED OUTLET 1 1/2 t (a). 920N 500 2 00 2 28 3 00 3 25 1 82 6 26 3 25 3 6 3 3 40 _ 3 50 8 58 76 83 46 159 83 1 7 , 1 6 1/2 (a) 300 1 50 2 22 2 75 2 25 6 4 6 318 1 3 9 761 x 15 920N _ — 2065 381 56 70 57 164 81 18 • Provides a direct branch connection at 3 /, ( a ) 300 150 219 275 225 646 318 39 any location where a hole can be cut 20 92oN 2065 381 56 70 57 164 81 18 in the pipe ' ( a ) ' 92oN 300 1 50 207 275 _ 225 646 318 1 38 , _ 25 2065 381 53 70 57 164 81 17 • A pressure responsive gasket piovides i "' (a) a 920N 500 175 2 30 3 00 3 31 192 6 29 3 00 3 5 3 2 the seal 32 3450 445 58 76 8 49 160 76 1 6 1 s 11 (a) a 9201• 500 2 00 2 28 3 00 3 31 1 92 6 29 3 25 3 5 ' 3 3 • Request Publication 11 03 for 40 3450 508 58 76 84 49 160 83 16 1 5 Mechanical -T cross assemblies 3 x ' 92oN 500 150 252 305 — 228 615 275 34 80 15 3450 381 64 78 58 156 70 16 ) • Pressure rated up to 500 psi/3450 kPa % (a) a 920N 500 150 249 305 228 615 275 34 on steel pipe, also available for use 20 3450 331 63 8 58 56 0 6 with HDPE pipe a) 920N 500 150 238 306 228 615 275 33 25 3450 381 61 78 58 156 70 16 • Sizes from 2 x'1"/50 x 15mm 1'4(4)tal 920N 500 175 255 325 356 , 228 615 300 38 37 through 8 x 4 "/200 x 100mm 3 2 (b) ° 3450 44 5 65 __ 83 90 58 156 76 1 8 ' 1 8 — - 1 'h (a)-ta 920N 500 2 00 2 78 3 50 3 56 2 28 615 3 25 41 3 8 40 (b) 3450 50 8 71 89 90 58 156 83 ` 1 9 1 8 2 (4)1 500 2 50 2 75 3 50 3 56 2 28 6 75 3 88 4 9 i 4 6 50 -;;, 92oN 3450 635 70 89 90 58 172 99 2 3 1 21 31/2 2 - 500 250 300 375 244 672 388 _ 38 90 x 50 92oN 3450 63 5 76 95 62 _ 171 99 J 18 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate) mated to one another t Available with grooved or female threaded outlet Specify choice on order to achieve cross connections ,r E Center of run to end of fitting # Female threaded outlets are available to NPT and BSPT specifications @ See page 7 for Fire Protection approvals and pressure ratings (a) British Standard female pipe threaded outlet is available as listed Specify "BSPT" clearly on order (b)For 761 mm threaded outlet, specify 2' /a' BSPT clearly on order § Vds approved for fire protection services ❑ LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAUI IC COMPANY ALL RIGHTS RESERVED iCtc'11.1lIC` 11.02_2 REV_L CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 1..02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS r Style Max. Work ` # Approx Size ,. No. Pressure ®. ' „� :,:r 1 %Dimensions' ,` Weight Each .,. ti K " y : °"�`"°> ��= ". ?; -i'- a.._:y:�,Y may:: r ` Z�w & q ��. 3 �i �: - , - �^?�u�� �m^i� _d, r �'S a tRl ? _' s��r 1,... 8, :•e .t1 ��:. s? +t • tl � ��': c�I .a � ` `ti:a; 1 ` i-:F' -. $$=4 -�, . i;.. _ 5 s ue • . Z . ... a >: i -a' n 1 „? F;:., l' : ti� F a — =«z _ TABLE CONTINUED FROM PAGE 2 4 x V (a) a j 920N 500 1 50 3 03 3 56 2 69 701 2 75 3 7 — /i1 Al IA IGI 100 5 3450 381 77 90 68 178 70 1 8 - I' r T %r " o ' + 92 500 1 50 3 00 3 56 2 69 701 2 75 3 7 _ r 20 , 3450 381 76 90 — 68 178 70 18 MI I (a) a 920N N 500 1 50 2 88 3 56 2 69 701 2 75 3 6 25 I 3 381 73 90 68 178 70 18 GROOVED OUTLET 1' / 920N 500 175 308 378 400 269 701 300 40 36 32 (b) 3450 44 5 78 96 102 68 178 76 1 9 1 8 _ Th (a)i "; 500 200 328 400 4 00 269 701 325 42 39 Y .. r Z > 40 (b) I _ _ 920N 3450 50 8 83 102 102 68 178 83 _ 2 0 1 9 _ ♦ 2 523N 500 250 325 4 00 400 269 701 388 50 46 PR 1 „ 50 3450 63 5 83 102 102 68 178 99 2 3 Z 1 I /Iii . #1 " ..• MI 7 1�r 2'k I 920 500 275 238 400 400 269 734 463 58 50 G 7 65 ( 3450 699 73 102 102 68 186 118 26 23 V t J ( 500 275 288 _ 400 269 734 463 — 64 1 o y 761 mm 920 3450 69 73 102 68 186 118 r 29 ist 3(a)t 500 350 331 450 412 269 773 512 84 64 80 920 _ 3450 88 9 84 114 105 68 196 130 3 8 2 9 FEMALE THREADED OUTLET - _ 1'/<(a). 500 175 308 378 _ _ 263 764 305 50 108 0 x 32 I 920N 3450 44 5 78 96 67 194 78 2 3 1'L>(a)❑ 920N 500 200 328 400 263 764 325 50 _ • Provides a direct branch connection at 40 3450 508 83 102 67 194 83 23 any location where a hole can be cut 2 (a) 920N 500 250 325 400 263 764 4 -00 40 in the pipe 50 3450 63 5 83 102 — 67 194 102 1 9 767 920 500 275 288 4 00 400 263 764 429 80 78 • A pressure responsive gasket provides 3 699 73 102 102 67 19 109 36 35 the seal 3 (a) 920 500 350 331 450 4 50 263 763 488 68 65 80 3450 889 84 114 114 67 19 124 31 3 0 • Request Publication 11 03 for 5 x 11/2 (a) 1 ( 920 500 200 403 475 475 316 970 369 74 76 Mechanical -T cross assemblies 125 40 i 3450 508 102 121 121 80 246 9 34 34 2 ( a ) ) 920 500 250 400 475 475 316 970 438 82 80 • Pressure rated up to 500 psi/3450 kPa 50 t 3450 635 102 121 121 80 246 111 37 36 on steel pipe, also available for use 2% (a)t, 500 275 363 475 475 316 970 463 83 79 with HDPE pipe 65 920 3450 699 92 121 121 80 246 118 38 36 761mmc 920 500 275 375 475 316 970 463 80 • Sizes from 2 x 1/2"/50 x 15mm 3450 699 95 121 80 246 118 36 through 8 x 4 "/200 x 100mm v3, -u ; 3 (a);tsy 920 500 350 381 500 463 316 970 531 84 88 , ^ , 80',` 3450 889 97 127 118 80 246 135 38 40 1330 :44,-' <- 2 •, 920N 500 250 375 4 50 _ 317 800 388 80 5 0 n ' 3450 63 5 95 114 81 203 99 _ 3 6 _ _ 1. ' 500 350 387 500 300 946 531 �80 80 920 — 3450 889 97 127 76 240 135 3 6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Center of run to engaged pipe end female threaded outlet only (dimensions approximate) Style 920 and Style 920N housings cannot he 1 Available with grooved or female threaded outlet Specify choice on order mated to one another to achieve cross connections to of run to end of fitting 8 Female threaded outlets are available to NPT and BSPT specifications @ See page 7 for Fire Protection approvals and pressure ratings (a) British Standard female pipe threaded outlet is available as listed Specify "BSPT' clearly on order (b)For 761 mm threaded outlet, specify 2 BSPT clearly on order § Vds approved for fire protection ser vices o LPCB approved for fire protection services 0 Approved fur use in China by Tianjin Approvals Company www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ICt.`dl.1lIC5 REV_L 11.02_3 1 CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 1.02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS .a,. zc ' 4 iiiiiiy :;, - I + ' _ s a' *r ,.t "'stile Moo .Work yi °a A `? ., ' e i ght Eaeha z. Size - No. Pressured ' -, w' Dimensions' -. . ' '• W � �k^ceight - �"N moo` @\ .trial d;-, i RZ. E';.. .. A x, a e \ �, t5� �E. � 4 �n . TABLE CONTINUED FROM PAGE 3 gammul 1 Yz 40 t 500 2 508 00 3 96 78 4 11450 3 30 3 209 23 3 83 25 370 2 /a �� In V � Me 1397 x 920N — I01 3450 - -- 84 0 2 t 920N 500 2 50 3 75 4 50 3 30 8 23 3 88 9 0 T � 50 3450 63 5 95 114 8 209 99 41 6 1 �/� (a) 500 175 43 5 513 379 915 325 51 4 3 v w I� 150 x 32 (b) 920N 3450 44 5 112 130 130 96 232 83 2 3 2 2 GROOVED OUTLET 1'1 (a) to 920N 500 200 4 513 513 379 915 325 54 51 40 (3)) 3450 50 8 112 130 130 96 232 83 2 4 2 3 2 920N 500 250 438 513 513 379 915 388 60 56 Y > .— Z —> 50 3450 63 5 111 130 130 96 232 99 2 7 2 5 • 761 mm0 920 500 275 415 521 369 1051 .63 [ 84 3450 699 105 132 94 267 118 3 8 A �� t ID 3( a ) t 500 350 4 31 550 513 369 1051 531 99 84 1i1 I T ` 1� 1 920 � � 80 3450 88 9 110 140 130 94 267 135 4 5 3 8 4 (o) 920 500 4 50 3 81 5 /5 538 369 1051 625 101 10 1 W I�I 100 3450 114 3 97 146 137 94 267 159 4 6 4 6 r 1590 x 1 %z (a) 920N 500 2 00 X 12 4 1 239 5 13 _ 3 63 3 7.5 73 40 3450 50 8 112 130 92 239 83 _ 3 5 FEMALE THREADED OUTLET - --- — 2 (a) 92001 500 250 438 513 _ 363 9 338 ' 80 50 3450 635 111 130 92 239 99 36 767mm'920 500 275 438 550 513 363 940 463 ) 95 95 • Provides a direct branch connection at 3450 699 111 140 130 92 239 118 ' 43 43 ^ any location where a hole can be cut 3 500 350 431 550 513 363 940 531 , 81 > 140 in the pipe 80 t 920 3450 889 110 140 130 92 239 135 [ 37 64 108 0111111 920 500 4 50 445 _ 538 363 9 612 _ 100 • A pressure responsive gasket provides 3 114 113 i37 92 239 155 4 5 the seal 4 500 450 ' 381 575 363 940 625 180 100 920 3450 114 3 96 80 146 92 239 159 8 2 • Request Publication 11 03 for TABLE CONTINUED ON PG. 5 Mechanical - cross assemblies "` Center of run to engaged pipe end, female threaded outlet only (dimensions approximate) • Pressure rated up to 500 psi/3450 kPa t Available with grooved or female threaded outlet Specify choice on order on steel pipe, also available for use Cente of run to end of fitting with HDPE pipe # Female threaded outlets are available to NP1 and BSPF specifications @ See page 7 for Fire Protection approvals and pressure ratings • Sizes from 2 x 1 /2'150 x 15 mm (a) British Standard female pipe threaded outlet is available as listed Specify "BSPT" clearly on older through 8 x 47200 x 100 mm (b)For 761 mm threaded outlet, specify 21/2' BSP1 clearly on order § Vds approved for fire protection services e LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ICtallllc 11.024 REV_L • CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS -`'.. Size` ` No Pressure@ , 'Dimensions; t_ '" , Weight Each 0 1 � = ' t P� I. T . r ry as x Q Z ti �r ;;: v o � ' z., � i < y .. < 7 • � ,,.. \c045:14 itaQ ak s e .;!.� a... _ -�, w.. ,: y <•_� . ; . .. 'z.,- ° 1c :,IP'' �?, D- .. ■ TABLE CONTINUED FROM PAGE 4 wwili V 1651 x 1 920N 500 1 50 3 88 4 56 _ 3 79 9 34 2 75 8 0 (i1 �� 1i 1 1Gr _25 3450 381 99 6 96 237 0 , 3 6 ,� 1' /,a 500 175 443 513 _ 379 934 325 84 - -4 -? V 32 920N 1' /z (a 3450 44 5 113 130 96 237 83 3 8 \_ _ Ili W � 500 200 44 1 513 513 379 934 325 84 54 v 40 ) f ❑ 920N 3450 50 8 112 130 130 96 237 83 3 8 2 4 GROOVED OUTLET 2 (at1 920N 500 250 438 513 513 379 934 388 85 60 _5_0 3450 635 111 130 130 96 237 99 39 27 761 mm) 920 500 2 /5 401 513 521 363 1051 463 86 76 Y .-- Z —> _ 3450 699 110 130 132 92 267 118 3 9 3 4 r 3 500 350 431 550 513 363 1051 531 102 84 _ 30 920 3450 889 110 140 130 92 267 135 4 6 3 8 – A T 4 (a) f❑ 500 450 381 575 538 363 1051 625 105 84 V 181 �� 181 T Nome 920 t 64/ 100 3450 11 3 97 146 137 92 267 159 4 8 3 8 8 2 (a) t 500 2 75 5 44 619 6 25 4 81 12 4 2 4 50 11 6 11 6 7 i I 200 x 50 920 3450 699 138 157 159 122 316 11 53 5 3 2 13 (a) 2 500 , 2 75 5 07 619 619 4 81 12 4 2 6 50 11 6 11 6 65 920 3450 699 129 157 157 122 316 114 5 3 5 3 FEMALE THREADED OUTLET 76 1 mm 1 = 1 920 500 2 75 5 25 _ 6 25 4 31 12 42 4 56 _ 11 6 3450 699 133 159 1 316 116 53 3 (a) to 500 3 50 5 31 6 50 6 50 4 81 12 42 5 31 12 6 11 6 • Provides a direct branch connection at 80 920 3450 889 135 165 165 122 316 135 57 53 any location where a hole can be cut 4 500 450 4 81 675 638 4 81 1242 625 153 125 In the pipe , 100 920 3450 1143 122 171 162 122 316 159 69 57 *' Center of run to engaged pipe end, female threaded outlet only (dimensions approximate) • A pressure responsive gaskel provides t Available with grooved or female threaded outlet Specify choice on order the seal Center of r un to end of fitting • Request Publication 11 03 for 8 Female threaded outlets are available to NPT and BSPT specifications Mechanical - cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings' • Pressure rated up to 500 psi /345O kPa (a) British Standard female pipe threaded outlet is available as listed Specify "BSPT" clearly on order on steel pipe, also available for use (b)For 761 mm threaded outlet, specify 21/2" BSPT clearly on order with HDPE pipe § Vds approved for fire protection services a LPCB approved fo1 rue protection services • Sizes from 2 x 1 /2'/50 x 15 mm 0 A roved for use in China by Tianjin A through 8 x 4 "/200 x 1OOmm pp y ) Approvals Company IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections www.victaulic.com iiictauluc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED >" REV_L 11.025 CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 1.02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920 920N and 929 Mechanical -r' fittings can best be expressed in terms of the pressure difference across the Inlet and branch The pressure difference can be obtained from the relationship below ® C and Kv Values Values for flow of water at +60 °F / +16 °C are shown in the table below Formulas for CvtK, Values: /� 122 = Q= Where: 122 = Q` Where. 0— IU�I ►1 C - Q = Flow (GPM) K Q = Flow (rn /h) Bug = Pressure Drop (psi) pP= Pressure Drop (bar) Q = C, x JP C„ = Flow Coefficient 0 = K x 4P K = Flow Coefficient Exaggerated for clarny Equivalent Length�,of ¢ S . r o e. _ - Outlet Size Schedule ,..•,,rz >, ^y>:. , 7 '' ,i. : ' , r 40 Carbon Steel Pipe o. - , ( 1, � ..., ,,, A ° ,�, , , r F (per UL 213 Sec. 16) .•g " `^ OUTLET : ' (C` 120)t FT, ',, , . _G/KV Values ,, _, �✓�:a '> , ,,� � .: =.� . `e. t ��� * '.:. ; r'" e? e x ? �a�g > .�,�� � ; ■ r ::-._,ittrmta : :fvNfo,v1;:ok:.mts;artat : ,.,.:��F•k... : e �,,• "p � .?1�� :<- ' � =::1� .y;,, ��.� >. ;ate �- - -�:r: t` =n: ':e� _ ��= Y= z:' a ?kv "��"�',`E � :�`°= •z ?�': �` =x,.� . , ��r'� �, ?°,a: ,; 1 .,�. :, a,.s.. ... 41E "✓,i;�Y�.,c,,, � ;: >i.E %�,�se%' a3V�,• " '�1•`aL�'.,���. ,. "��." x)e .„ 8 a ; i° H- , " , ,,,, ^ . ? ^.�: �.ar av�" %,:>�..:: >; �� : Fig' 1 I 08 it 15 _ I 213 _ 2 94 _. __ _ _ " "3l4 -- 1 050 4 16 20 267 137 1 1315 .._..__ _ ."_ ...... _ _._.... - - 21 25 337 8 18 .1:% 5e 48 • 1660 5' /z - - -.. 6 32 427 429 411 1 1/2 1 900 53 51. 40 98 11 11 454 454 2 2 375 112 10 50 603 _ 2 j 9 10 96 891 ��� "_____ " "� 2875 20 12 Yz 119 150 65 _ 730 102 1285 761 mm 3000 - - 16 161 761 1381 3 3 500 249 237 80 889 14 15 'h 2134 2031 4 , 4500 421 401 , , 100 - 1143 1 20 22 3608 3436 t Hazen - Williams coefficient of friction is 120 *Pipe with a wall thickness of 0 1651n /4 2mm www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED lictaulic` 11.02_6 REV –L CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication Listings /Approvals die subject to . change and /or additions by the approvals agencies Contact Victaullc for performance on other pipe and the latest listings and approvals Ap Run Size Outlet' Size ' Pipe - - Rated Working Pressures - psi/kPa �-.`? ' •�,� . Wit= - �.� � :a. \ a . �.> �:�:� ` :�� La�ass , <_:.a >e� ^ --„,,,,L, '� � y .� .- �ac:� ,�4'� ,•� , a _ w• s ` � .•�€ -ate;` 43,7— �`- ,, `• � � , o :"`-` a . � z 2 3 to i 21/2 - 6 2 875 - 6 625 All 10, 40 X 400 400 400 290 232 362 65 - 150 73 0 168 3 2755 2755 2755 1999 1599 2496 21/2 - 4 2 875 - 4 500 All DF 300 300 300 290 232 362 6 5 - 100 730 - 114 3 2065 2065 2065 1999 1599 2496 21/2 -4 2875 - 4500 All SF 300 _ -- 300 300 290 232 ' 362 65 - 100 73 0 - 114 3 2065 2065 _2065 1999 1599 2496 _.�..._ - �� 6625 - - -- 300 300 250 7.90 232 362 150 168 3 3,4 10 2065 2065 1724 1999 1599 2496 6 6625 300 300 300 290 232 362 150 1683 3 4 30,40 2065 2065 2065 1999 1599 2496 £ 8 625 400 145 200 2191 21/2 10,40 2755 1000 8 8 625 300 _ 250 145 200 2191 3 4 10 2065 1724 1000 8 8 625 300 300 _ 145 a _ 200 2191 3,4 30, 40 2065 2065 ■ 1000 NOTES 10 r efers to Listed /Approved Schedule 10 steel sprinkler pipe 4 0 refers to Listed /Approved Schedule 40 steel sprinkler pipe DF refers to Listed /Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company SF refers to Listed /Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC -TAP II HOLE CUTTING TOOL FOR The Vic -Tap II hole cutting tool is designed for use with the Style 931 Vic -Tap II Mechanical -T unit, 4 - 8" /100 - 200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical -T and Series 726 Vic -Ball Valve The Vic -Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi /3450 kPa I The Style 931 Vic -Tap II Mechanical -T unit is a full port ball valve which can be mounted on 4" /100mm, 57125mm, 67150mm and 8"/200 mm diameter pipe The Style 931 comes with a 2' 765mm z f grooved outlet A,. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with ., 4„, safety codes For more Information refer to publication 24 01 3 , it Si i rO www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED I REV_L 11.02_7 r a y ,' t t t v..r '.:a�` T ! yy q r.. t.r. t•� t- x f ,, i L # .k„ , .M .,; r� 3, w 40•044$10. s +~ t. o �:� � � � �., ,, I ke; FeA . .... .. , >. �..e a< .. ...,6 .. Mechanical -T Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the I -100 Vrctaulic Field Installation Handbook for the product • you are installing Handbooks are included with each shipment of Vrctaulic products for complete installation and assembly data, and are available in PDF format on our website at wwwvictaulic corn WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details NOTE This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly Instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without Incurring obligations For complete contact information, visit wwwvictaulic corn 11 02 1480 REV L UPDATED 05/2011 tct'c�UI.0 VICTAULIC IS A REGISTERED TRADEMARK Or VICTAULIC COMPANY © 2011 VICTAULIC COMPANY AU RIGI ITS RESERVED H < <« 11.O2_L , . . . ivt7.12 1.6 , ci FN STOCK: HEAVY WALL, SEAIVILESS, STANDARD WALL PIPE, FITTINGS AND FLANGES STEEL_ PIPE I GENERAL DATA sQ-Kif IA. 'A Slar0tird (P - Sci" -- , 11•00:4 4 41 f (Am SIrung Scrk Schcovikv 100 Schtici411 20 Sk;414K114 v 140 . .ktom.,k 1 1(10 X.X.S11v E , f)13 wr b WI l',1 WI fr&MI '#T IrmiE WT ' W ill VoT Ibm)/ Itfr EC' VIT 114 VIM trot VIM 11.101 'NWT L14. YoT iho :AT 4ffixt 1 .11111111 0,w 024 00E2 , 0.24 ISM -- El III 1 116' 11.405 0.040 0, 3 0 (4,,t 0:31 all I 1:4° 5- n•5°40 NIFIS -^ 3-5'. all f),W ma 4.). C41#1 ' 0,43 mg ,,,,..54 , .1,c., C S4, I ;Yr 1 0.2:76 0,1125 17.43 MI o.cioi 0 ::::: 0 01 ii.,5 i . 1=11 . 1 .-'6 C, la' 01;40 0.o3 mg 1111 mg 0 26 0 109 ; 1)a5 0.140 1,I30. ( I14 1.09 al ° 0": 1 1 11: : EI 121 0.31.2 mg O:1 113 fl 11 1 1.1 OEM fi 11 1.40 al I .. L1 1 , 1:,315. cw 141 all 3.1....-1 t 53 0.133 , 1,64' IIIIIMIIIIIIIMII 11111.1111111 EMI 3.fifi : 0...Fri 1 1,°4' t - .F4S0 0.19ID 1,31 11,140 2 ? ' 0140 i 1,1°C; 11.1Q13 3 00 fi1c • 9,00 I 1 17 ' 1.900 0100 2.0 0,14.5 ? , ,s, 0 145 ` 2 ,E2 0.70 , 3 63 o A:41 3. 11111111111111E 0;#1 4.m° ),-4. 7 ', 2.3'S 0.100 2.24 (1.1.f,4 3 EE 0 12 . n.e.6 0.716: 203 II 21# s.on al 0.3 ,, ME gasp: i 2 ilr 1 fi Es 0.1 v...1 . , S. 41, • Ma - r°E6 13e43 ":451111/111111111111111111 0.3:16 1102 0.052 13,r,1 =, 3 3' .40 0.170 4. NM M2 0 2 el -.56S 11=1 (I X4 1111111.111111111111111 0.45 o.fic 1a 1 En IIII_,_ - _ rEilestimillilisliM EIN111111111 3 14r 4.0) 0,1N 4,0E 1.1.11 mg t12 <MO 3.12 0,31$ f 1.62 112,313 12%52 ENE 0,fi rg 0 .1 Zg. Z2•011 4' 4.01* 0170 6.2:7 :,-..- - fi.F0 i1. 3j 33 1b.111) 0.43E 0.511 0.6% mg ral 4 1 5' 5.5E3 0134 0 14 rill 0.2,54 . 0.."41,113 , , 11.3,..* 2030 EMI 20 SUN - . - 040) 7 , . all " 0357,6 Egli 0.160 M.% ; ,..._.......,_ c 2.2;.S 0.14 9,3-fl 0,2:K. 1$ cal aZao ',Ogg 11.4:: 2E.20 o43°.) moil 0.24; 32.43 0.-1Q 45.3.9 0.061 63.21 0.145 13 7,2.3,5 0.201g 14 ix5.12? n5.1 42 ?IL% 0.4011 35.21 11,5001 4343 o 43 0.504 5101 0.., 2011 0.312 67.27 09(4 r:F...L6 0,j5 m44; 10" , t0.:11 0.125 162.. 0.222 22.06 0301 34.2:. 0.36 s 40.02 0.262 ' 40.E2' 0.500 24.. 2 0.5001 54.,,...9 0.934 64.49 0,19 ....10 0.244 89.35 1.1100 104.23 1.'25 115. 5 4 .930 104.231 12' 1 1;2.1113 0.1E0 24.19 0250 33.41 2.3& curs 49.21 0.402 63.5 0.222 3.22 0.500 69.48 ak26 ez.01 0.244 10,:42 1.003 125.61 1.22 139.21 1.312 t 20.42 t.000 125,21 14 I - 4.07. , 0 0.250 26.. .5 0.312 mog 13.321 2422 13.36 mg 0.432 ' 6 3.50 0.594 89.1 3 0 .2.* 2. C. 0..60 1C2.2111221 13056 1.094 100.93 1.250 1 1.422 0 - 16' 015.0:0 0.29.1 42.03 mg 52.32 11:312 2224 a.ors mg mon eza5 0.220 10,_oo 0.9,0 K.ss 0.844 124.14 1.031 MEI 1.219 192,61 El 229.85 1.254 2'5.46 1S: to.oco 0.2rzi 4 144 lar 2 mg 14.121 2223 0.3:6 ro.ss 0.E 2 *1441 0.. no 112.30 0.5K 95.24 .0.912 1.118 1.52 =2 1.355 242..4 1.522 2'4.43 1. 131 3013_0 ------1 ,.. ....- - , - ar 20.000 0.2sci 62.L.2 0312 12,611 13.500O31114.23 09r6 13.2.2 0.29 : 12322. 0.212 162.55 0.500 ,104.23 1.05t Z1.5.05 1.2E1 256.24 1.500 26E25 1.,. 34 1.929 re 22.1:1X1 0.25'0 69.13 03-5 22.59 1500 '14.92 13.316 en 02 2I7 _53 0 .r.ex .° 114:92 1.125 224.05 1.2.2 mg 1.225 223.94 1.22 403.38 2.25 451.40 -1 - elm 24' '24.000 0.220 63.4.% 0.3..2 94_1 0.%2 140.8" 0.3E6 06213 .W1.43 0.953 223 51i 0.5(I0 125.21 1.210 mg 1.031 Egg 1.531 22A14 2022 463.51.. 2.344 54 2.&1 26' 25.060 0.312 mg 0.208 132.30 13.9[6 rEll o.i.y..x. 1:6.30 Ell 26° i 2BCCO 0.312 0Z35 0.2GO 142.02 2620 1E120.0 0.319 110.14 0.50) 146.09 1 -------4 L 1 . , DY 30./X0 0.312 9002 asap 10-018 2.629 122.22 11.3r6 112,..76 11.500 15.7:63 I , -I- : 32" 32.000 0.312 1015.29 0.520 162.31) 2.629 52 0.S 126.12 0.232 23029 11.9X1 169.30 f I 209 3E . , .- i I I 1 34' 34.06() 0.312 MI 0.51.11) 1,2 0 .06 .625 222, 0.3 0. .2 1:g. .21 532 '24500 IMO , 1E9.132 L I I i i I 1 1 . w , 21.6.CCO 0.312 11;0.15 0902 125216 2.622 23519 0.316 142.81 0.50 222)32 MI 129.C3 AquaFlex Stainless Steel COOS Z ® 3 LISTED Sprinkler Fittings SERIES AQB BRAIDED AND SERIES AQU UNBRAIDED FLEXIBLE HOSE ASSEMBLIES AquaFlex" stainless steel sprinkler fittings piowde spnnklei installation on suspended ceiling grids, wood or metal stud or hat furring channel sheetrock ceilings utilizing a Flexible, stainless steel hose Refer to Installation Manual (I- AquaFlex) for all applicable ASTM ceiling material and installation standards AquaFlex Stainless Steel Flexible Drop 1 -Bee° bracket (patented) allows complete lateral alignment of sprinklers during installation The bracket provides center points and reference marks 6' and 12 " /152mm and 304mm from the tile edge (on the 24" bracket) for ease of positioning without need for measuring The system requires no welding for assembly I The Series AQB braided 1" nominal diameter system is FM Approved for T Bar Grid suspended ceilings and metal or wood frame sheetrock ceilings For system dimensions, see pages 6 -13 2 The Series AQU unbraided 'V" nominal diameter system is UL 2443 Listed For system dimensions, see pages 14 15 3 See pages 2 -3 for specific Series AQB VdS Approvals • Braided flexible stainless steel hose lengths (length includes branch line nipple and E 5 5 " /140mm straight reducer) 31, 36, 48, 60, 72 "/790, 914, 1220, 1525, 1830mm OPEN-GATE BRACKET HOSE RO B B raided D e -BEE g OPEN -GATE BRACKET (Series AQB Braided hose shown). Unbraided flexible stainless steel hose lengths (length includes branch -line nipple and 5 5 " /140mm straight reducer) 24, 31, 36, 48, 60, 727533, 790, 914, 1220, 1525, 1 -BEE 2w 1830mm • Branch line nipples for attaching to rigid pipe • Ili and 1/4"/15 and 20mm straight and 90° reducers for connecting sprinklers • FM Approved, cULus Listed, patented, light - weight pre - assembled, ready -to- install 1 -Bee mounting bracket available in 24 and 48" widths Note 48' width not cULus Listed • FM Approved Institutional bracket for wall or ceiling installations also available (see Submittal Publication 10 88) • Optional pre - assembled systems with factory - installed sprinkler heads available In these systems, spunkier connections are leak- tested by Victaulic Contact Victaulic for sprinkler model availabilty TECHNICAL SPECIFICATIONS Maximum Working Temperature: 225F/107 2 ° C Maximum Working Pressure: • 200 psi/1375 kPa (Series AQB Braided) • 175 psi /1206 kPa (Series AQU Unbraided) Connections: To branch line (inlet) via 1 "/25 4mm NPT /BSPT male thread To sprinkler head (outlet) via 1/2" or 3 /4 " /15mm or 20mm NPT female thread Minimum Bend Radius: • 7 " /178mm (Series AQB) • 4 " /102mm (Series AGO) Maximum Number of Bends per Flexible Drop: See friction loss charts later in this document • Do not bend within 21 "/63 5mm from connection nut Maximum K- Factor of Sprinkler to be Connected to Reducer: • K5 6/8,1 (S I) ('/z" reducer) • K8 0/11,5 (S I ) (Series AQU - 1/4" reducer) • K14 0/20,2 (S I ) (Series AQB - 3 /4" reducer) JOB /OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED IC.t.`calJllc REV_I 10.85_1 FIRE PROTECTION PRODUCTS - FITTINGS 10.85 0.85 AquaFlex Stainless Steel Sprinkler Fittings FRICTION LOSS DATA - STRAIGHT REDUCERS * .. ': Equivalent'; q b'5 . sEguivalent : x _ Length'of v .Length of !.'` 5 y;,..• "steel pipe. t - steel, pipe' . .. - - according to .r according to r, - Equivalent Maximum " Equivalent' Maximum DIN 2448 DN25 i Maximum DIN 2448 0N25 .. Maximum a`6 Actual Length of Length of Number of Length of Number of (33,7 x 2,6) and r Number of (33,7 x 2,6) and Number of ngth'of. ,Stainless Steel 1 inch /33.7mm 90' Bends at 7 1 inch/33.7mm 90' Bends at 4 relating to a flow 90' Bends at 3 relating to a flow • 90' Bends at 3 ' 'Stainless; Steel 'Flexible,Hose' Outlet Sch. 40 Pipe inch/102mm- Sch.40 Pipe . `inch /102mm velocity of inch/76.2mm - velocity of inch/762mm Flexible Hose inches /mm ". Size feet/meters Bend Radius' feet/meters Bend Radius' 5 m /s;(m) "'" Bend Radius' 5 "m /s, (m) Bend Radius' '"` ""'a s? tf .e `?- , '�otc'e �. r : : - ;`7 i y: - ^ _ F t :".:.� . gym �. � , � , v`� " .`iii e � y � �� ,.�� ..., p '' �+ v '` ' � . ,�;.� " '' '1. �� i . '� - � :,� � "., .. 3E xt 3 F°e. F y �� � -C. c• ` � 3�. :.,�; � �- � l 0 •, aFf �b�;a -�,£ F: n.^3 � -..� 4 i: °�., �1- \u ` ��� r _ .>:,.. .. �.�..� ,. \\ = � o� �� � � � � t om. -. : �? 4' , s;. ,~`;ag� 1iP \ Y N/A N/A - 18 28 5 5 24" N/A 700 N/A N/A 32 2 N/A N/A N/A N/A t. 98 /2 9 6 , 27 173 144 31 31 31 29 82 53 44 790 780 3/ 82 1 33 2 173 3 14 2 2 5 _ 101 53 44 ._ -- - - - - - - - '/z 11 4 44 200 - -- - - - 16 - - - - - 36 40 34 F 13 61 50 36' 915 1000 99 2 48 3 200 3 164 3 30 1 61 50 V 171 53 269 223 48 48 52 162 82 68 48 1220 1220 3 3 3 165 55 269 223 50 168 82 68 %z 214 -- -- -'- - - 8 - - - - 33 275 60 61 65 ! 207 102 84 60 1525 15 a 4 4 4 20 1 63 33 4 275 61 192 102 8 -- - - - ---- - -- — 273 --- - - -- - 3 - - - - -�- ;00 331 -- - -- 72 72 8 3 22 3 12 2 101 72 1830 1830 n . 3 3 3 . 3/4 26 2 76 40 0 331 79 232 122 101 FM and UL NOTES: 1 Series AQB and Series AQU systems have been tested and Appioved by FM Global and Listed by UL respectively foi use in wet, dry and preaction systems per NFPA 13, 13R, and 13D FM 1637 and UL2443 standaids for safety include but are not limited to, pressure cycling, corrosion resistance, flow charactensitics vibration resistance, leakage, mechanical and hydrostatic strength 2 Differences in equivalent lengths are due to varying test methods per UL 2443 and FM 1637 and VdS standards Refer to these standards for additional infor mation regarding friction loss test methods VdS NOTES: Series AQB is VdS Approved for use in wet systems only Only VdS- approved pendent spray sprinklers of nominal diameters 10 mm, 15 mm, and 20 mm with K- factors 57 80 and 115 may be used This approval only applies to the use in suspended ceilings of the following manufacturer's ceiling systems 1 Odenwald, Systems S2, S3, and S15 2 Richter, Systems 4l -<5 111 -116, 133 -134, and 165 'Number of Bends- A higher number of bends may be permitted provided the sum of degrees is equal to or less than the total maximum allowable degrees of bend (e g Two 90° bends equal 180 Three 90° bends equal 270 °) EXAMPLE: A 48 -inch Series AQU hose installed with two 30° bends and two 90° bends at a 4 -inch bend radius is permitted and considered equivalent to the data in the table shown above In this example, the total number of degrees is 240 °, which is less than the allowable 270° *These length hoses are only available in certain regions Contact Victaulic for details , www.victaulic.com VICTAUL IC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VIC1AULIC COMPANY ALL RIGHTS RESERVED tfa o'11.1�IC.F 10.85_2 REV_I FIRE PROTECTION PRODUCTS — FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings FRICTION LOSS - ELBOW REDUCERS F '. y 4 Length of .steel pipe; ` " according Equivalent, Maximum Equivalent . Maximum ;• DIN 2448 DN25 Maximum ' Length of Actua - Length of` Number of Length of Number of (337'x2,6)and Number'of Stainless Stainless'Steel 1 inch/33.7mm 90' Bends at i7 1 inch /33:7mm 90' Bends at 4 relating to 'a' flow 90' Bends at 3 4 8"/123 mm Steel Flexible Flexible Hose- Outlet Sch. 40 Pipe inch /102mm . Sch. 40 Pipe' inch /102mm - velocity of 5 'inch/76.2mm Ti. Hose • inches/mm Size . feet /meters' Bend Radiu feet/meters Bend Radius'' ,m /s; (m) Bend Radius. c ' ,EE €y _��:�w�- ;�.. «�.«�4' �_ . a�!_r -�.,.f # .� § r�'`�'.�mtY e...�2, :,.�� *< .. ::�.�Q , � a 1/2 N/A N/A N/A N/A Short 90° elbow reducer 24° N/A N/A • N/A N/A ,a N/A N/A N/A N/A V, 3 N/A N/A 5 3 A 31 31 790 N/A - / 6 9 3 N/A N/A l 5 3 l -- --" -- "' 298 - - - N/A N/A 200 36' 36 N/A - - - �t- _ - - 63 "/161 mm 915 242 2 N/A N/A 200 3 74 61 48 1/2 31 4 N/A N/A 8 9 48 1220 N/A / 299 3 N/A N/A 2 3 869 33 A Long 90° elbow reducer 60 60 N/A '/2 � 6 N/A N/A o z 1525 3/ 3 3 4 N/A N/A 3� 4 3 _.... __._- -- -- iz 4 6 S -- -- -- -- - N/A N/A x'00 72 la l 12 2 72 1830 N/A 386 4 N/A N/A c00 3 11 7 12 2 FM and UL NOTES: 1 Series AQB and Series AQU systems have been tested and Approved by FM Global and Listed by UL respectively for use in wet, dry and preaction systems pei NFPA 13 13R and 13D FM 1637 and UL2443 standards foi safety include, but are not limited to, pressure cycling, corrosion resistance flow charactensitics, vibration resistance, leakage, mechanical and hydrostatic strength 2 Differences in equivalent lengths are due to varying test methods, per UL 2443 and FM 1637 and VdS, standards Refer to these standards For additional information regarding friction loss test methods Vd5 NOTES: Series AQB is VdS Approved for use in wet systems only Only VdS- approved pendent spray sprinklers of nominal diameters 10 mm, 15 mm, and 20 mm with K- factors 57, 80, and 115 may be used This approval only applies to the use in suspended ceilings of the following manufacturer's ceiling systems 1 Odenwald, Systems S2, S3, and 515 2 Richter Systems 41 -45, 111 -116, 133- 134 , and 165 'Number of Bends: A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bend le g Two 90° bends equal 180° Thiee 90° bents equal 270 °) • EXAMPLE: A 48 -inch Series AQU hose installed with two 30° bends and two 90° bends at a 4 -inch bend radius is permitted and considered equivalent to the data in the table shown above In this example the total number of degrees is 2 °, which is less than the allowable 270° *These length hoses are only available in certain regions Contact Victaulic for details www.vlctaulic.com VICTAULIC AND AOUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ictalL.111lC REV_I 10.85_3 FIRE PROTECTION PRODUCTS - FITTINGS 10.85 AquaFlex® Stainless Steel Sprinkler Fittings PRODUCT DETAILS - Series AQB Braided System • Ck� kid Ik Yf� P 5 5'/140 mm straight reducer C 1 HI II it i ilil II��IIIII I ) -- Item Description i 7 0 1 n 9 0/229 mm straight reducer 1 Hose 1( }' 2 Adapter Rin IIIIIIII I I �--, a CIIIIIII I 11111111 ) 4 Nut 3 Seal I I IIII'Ijlll ll��Illfllllljll i 'llillllllli��llilllillllll � uu 1u II Inn 1 1 r :t5 t4�s tkt �.. r ���������j� ■krill 1 3 0 7330 mm straight reducer 5 Nipple 6 Biaid I•- 21/4 --..] 7 Collar Series AQB Flexible Hose - Braided (1" nominal diameter) T 63"/161 mm 48 "/123 mm V Short 90° elbow reducer Long 90° elbow reducer PRODUCT DETAILS - Series AQU Upbraided System ® a P Item Description. / 1 Hose �; � :, z Adapter Ring _ 1.1.111.1111111 dd ► Idl1111IIII��II 11111 1 3_ Seal tt�1II111Wt I CII IIIIIIIIII II IIIIIIIIII _ a Nut • • ululm m 111 1111 111 5 Ni • •Ie r- 21/4 Series AQU Flexible Hose - Upbraided 5 5 7140 mm straight reducer (Ye" Nominal Diameter) NOTE For assembly options, including factory - installed sprinkler heads, consult Victaulic Product Ordei Form SF - 35 which can be downloaded from wwwvlctaulic corn Regional availability www.vlctaulic.com VICTALILIC AND AOUAFLEX ARE REGISTERED TRADEMARKS OF VIC IALILIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED - ..„ —„,a, 10.85_4 REV_I FIRE PROTECTION PRODUCTS — FITTINGS 1 0.85 AquaFlex Stainless Steel Sprinkler Fittings COMMERCIAL SUSPENDED CEILING INSTALLATION - aZu 1 -BEE BRACKET 1 -BEE .Item .- . Description - - , 1 247610mm or 4871219irrm Square Bar 1C1 ,13 2 Center Bracket Assembly 3 End Bracket Assembly � 4 Sheet Metal Screw ` 4871219mm vers FM Approved only 2 7 ,1 1 V ra . , -- O 0 I �'I • c Patented 1 -BEE One -piece bracket with center open -gate assembly 1 -BEE BRACKET WITH ADJUSTABLE END BRACKET (REGIONAL AVAILABILITY) Item Description 1 2757700mm or 5571400mm Square Bar © 0 2 Center Bracket Assembly 3 End Bracket Assembly 4 Sheet Metal Screw 5 Ad ustable End Bracket Assembly 2757700mm and 5571400mm sizes FM and VdS Approved � CO - 71; ..,....,—; 2 . 3 OS tt Optional adjustable end - bracket to allow system Installation outside of standard ceiling panel dimensions www.victaulic.com VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ictaullC REV_I 10.85_5 FIRE PROTECTION PRODUCTS — FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings 1-BEE ADJUSTABLE BRACKET FOR HAT FURRING CHANNEL APPLICATIONS ' (REGIONAL AVAILABILITY) Item. ' Description • • I`* 0 1 247610mm Square Ba, _ �. 2 Centel B∎acketAssembly , I� 3 Ad ustable End Bracket Assembly " FM Approved only it ✓ A �fr O v„ 0 X4 0 www.victaulic.com VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICLAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ictaulic' 10.85_6 REV_I FIRE PROTECTION PRODUCTS – FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly SUSPENDED CEILING GRID A FLEXIBLE DROP ASSEMBLY WITH RECESSED SPRINKLER / 7 / R See Chart 11/2 / 1'k "/ 38mm 38mm' fi 1 "/254 mm Nom ID 21/2"/64 mm 111 A min straight sectioi_ ITT before bending r , See Chart SIM IMO rism ttt i !_ __ 2 /60 mm max hole __ RIM M(T)c=) W ^ -1 2 "/51 mm O — J� —I 3 /a "/ urn hole 180 mm 3146/ 40 60 mm = I (�) PA 11E7110 IIM 98 mm si lm ■ upj t ) l k" /38mm v 1 " /13mm lid \ 10/45mm i Typical ceiling �_� tile Typical finished ceiling face ��r WARNING: Typical T -bar grid and ceiling tile 24 "/610 mm or 2'5/67 shown Variations oft bar and tile r 48 "/1219 mm OC > r 74 mm may be used but may result in dimensional changes from V2708 /12.7 mm MAX. RECESS V2708 MAX. EXTENSION layouts depicted in this submittal NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical T -Bat installation and the corresponding minimum clearance dimensions if one 90° bend is impai ted to the hose Hose Clearance Chart R Minimum 7 Bend Radius 178 A Min 14 '/ 368 www.victaulic.com octaulic VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED — . <-- .w-.. ma- --- REV _I 10.85_7 FIRE PROTECTION PRODUCTS – FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly SUSPENDED CEILING GRID FLEXIBLE DROP ASSEMBLY WITH CONCEALED SPRINKLER i /" / / R See Chart 11/2 " /� 11/2 / _ I 38mm 38mm i T um 1 " /254mmNom ID 2'/z "/64 mm min straight section ME before bending i∎ == See Chart !_ -ii ICI WARNING: IAI �� Typical T -bar grid and ceiling tile MILIM shown Variations ofT -bar and tile =� may be used but may result in dimensional changes from == layouts depicted in this submittal __ ____ �= 2'/6"/68 mm ` max hole ' 2 mm ._. _ tat ==== — — _ ._. ` mi n hole ' 1 .._,......7„...,, ____ _ _ _ E a E= - -E . 1 ip " 80 mm KV 60 mm III iriiim■:7m= NW= © ■ o j 40 i� r 1' /z /38mm ------ Yz /13 mm Typical finished 3116 " / Typical ceiling tile 24" /610 mm or ceiling face 78 mm 48 mm OC V3802' "/12.7 mm MAX. RECESS V3802 MAX. EXTENSION NOTE Hoses permitted to be bent in alternative configurations What is shown is a typical T - Bar installation and the corresponding minimum clearance dimensions if one 90 bend is imparted to the hose Hose Clearance Chart R Minimum 7 Bend Radius 178 A Min 6/ 410 www.victaulic.com VICTAULIC AND AOUA[LEX ARE RFC ISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ictaulic' 10.85_8 REV_I FIRE PROTECTION PRODUCTS - FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly SUSPENDED CEILING GRID FLEXIBLE DROP ASSEMBLY, LONG ELBOW WITH RECESSED SPRINKLER . /_,,, 1'/ / " / ,,,,,p._ _ _ 38 mm 38 mm ■ A 63 "/161 mm See Chart 2 % "/60 mm -- max hole 7JN — —�� — 3Ya / min hole' i / 6 MI it'll. 313/fi , 60 mm — IIMMIP 11 — !! P1/2 "/38 mm ME 7_--- A emigiughrxe Lfl I R. ., Yz "/13 e/ . •,11r• 1'/0 "/32 mm s �.° /45mm �I I Typical telling . 1/a n <. tile Typical finished ceiling face -n. WARNING: Typical T -bai grid and ceiling tile 24 "/610 mm or 2 / shown Variations ofT -bar and tile 48'71219 mm OC 74 mm may be used but may result in V2708 "/12.7 mm MAX. RECESS V2708 MAX. EXTENSION dimensional changes from layouts depicted in this submittal NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical T -Bar installation and the corresponding minimum clearance dimensions if no 90. bend is imparted to the hose Hose Clearance Chart Min 515 /me 151 A Max 6 %„ 163 • www.victaulic.com VICTAULIC AND ADUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED .t`dJul.cfi REV_I 10.85_9 FIRE PROTECTION PRODUCTS — FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly SUSPENDED CEILING GRID FLEXIBLE DROP ASSEMBLY, SHORT ELBOW WITH CONCEALED SPRINKLER 1Y"/ 1Y „ / 38 m m' r-38 mm WARNING. ' I 1 i TypicalT - bargridandceilingtile 01111111; I shown Variations ofT -bat and tile - may be used but may result in dimensional changes from 48 "/123 mm -- layouts depicted in this submittal A 2c /iC /68 mrn See Chart max hole 21//60 mm _ _ A min hole 0 i v 3va °/ 80 mm W � \ I♦E / L0 r nn ME � i ∎iW�i I O Mw 11 PIIi r k �r rl �I _ N I II ' 1 �A II 1 �+ 1� III -, f � t.a _ I 1 I _ -� \ i� / ' it II u�111 -,{ !! P/: "/38 mm j l i. Et � � I gill i ---- - „ /13 mm Typical ceiling tile lypical finished f I 24 "/610 mm or ceiling face 3 /,."/ I 48'/1219 mm OC ' 78 mm V38021/2"/12.7 mm MAX. RECESS V3802 MAX. EXTENSION NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical T -Bar channel installation and the coi responding minimum clearance dimensions if no 90° bend is imparted to the hose Hose Clearance Chart Min 6V:6 154 A Max 16 167 www.victaulic.com VICTAULIC AND AOUAELEX ARE REGISTERED TRADEMARKS OF VICEAIJLIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED A'C21UlICm 10.85_10 REV FIRE PROTECTION PRODUCTS — FITTINGS 1 0.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly HAT FURRING CHANNEL INSTALLATION FLEXIBLE DROP ASSEMBLY WITH RECESSED SPRINKLER S i R ' See Chart 1 '/z" /,,,[ 1'h I 39mm 38mm t 1 "/254 mm Nom ID 2Yz "/64 mm A mm straight section before See Chart 1Tro7 ' Z ' 2'/e /60 mm = bending max hole .. _u 2 "/51 inm min hole aaaaaaa� _ _ Max ? 79 mm ri _ _— Clearance / \ = = 3Y4 "/83 min 2 / ` _ _ 1MI 5 0 in l . I . Iwo I o � 3° "/ 94 mm ■ i1 InnNE �i M 1 I 1 1 Np /a /23 mm Ili \11 � 'o � gm . \ � ��� T �, j � m m ad' I lr : +•�I s // "/13 mm ' P /n "/32 mm 1 " /45 rnm $T11 ...6 / ----__ Typical ceiling tile Typical finished ceiling face 1 �.... WARNING: Typical 16 "/406 mm - 2'`- /is "/ , Typical Hat Furring Channel and 24 "/610 mm OC 74 mm ceiling shown Variations of channel and ceiling may be used but may V2708 1/2"/12.7 mm MAX. RECESS V2708 MAX. EXTENSION result in dimensional changes from layouts depicted in this submittal and /oi irnpiopei lit NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical hat - furring channel installation and the corresponding minimum clearance dimensions if one 90° bend is impacted to the hose Hose Clearance Chart a R te � F: , —,. vii v .4 7 R Min 178 Min 14 /16 370 Max 15'616 383 www.victaulic.com s. VICTAULIC AND AOUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED 1�.ta1�- 1lI�i5 REV_I 10.85_11 FIRE PROTECTION PRODUCTS – FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly ■ HAT FURRING CHANNEL INSTALLATION FLEXIBLE DROP ASSEMBLY WITH CONCEALED SPRINKLER I . i / i / R See Chart 1 \ I'/z "/ _� 11/2 "/ 38mm �38mm� 1 1 "/254mm Nom ID 2Yz "/64 mm min straight F section before Fg‘-1° belling _ See Chart I t i Iw Max 2"66'/68 mm — — — = Clearance inax hole 3'4"/83 mm 2 /e" /60 mm � .III._� _ � min hole ' /13 1 ___ X1 1. El l it i o r 1 = = = la i . t em iz .. ,/,‘ _ /: \ U 79 mm 2',// MI 58 mm 1116,1 r ''- l i d + ` - - ii �l iii 1110,1 � T 1 ^ " II �r� 1 : . 11 1 'Ay 23 mm / 414 _ 7 � N. ,� �� � �1 1/2 /13 mim � 3'bo / t 78 mm V2'/13 mm Typical finished V3802 MAX. EXTENSION WARNING: Typical ceiling tile ceiling face Typical Hat Furring Channel and ceiling shown Variations of channel and ceiling Typical I6 "/406 mm > may be used but may result in dimensional 24'/610 mm OC changes from layouts depicted in this V3802 1/2"/12.7 mm MAX. RECESS submittal and /or improper fit NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical hat furring channel installation and the corresponding minimum clearance dimensions if one 90° bend is imparted to the hose Hose. Clearance C hart. Ir. 4 7 R Min 178 Min 391 A Max 15% 397 www.victaulic.com •ctaulicc VICTAULIC AND AOUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ��..>. 10.85_12 REV_I • • p FIRE PROTECTION PRODUCTS - FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly ■ FIAT FURRING CHANNEL INSTALLATION FLEXIBLE DROP ASSEMBLY, LONG ELBOW WITH RECESSED SPRINKLER • F 1'/ 7 11/21/_„ 2'/7/60 mm 38 mm 38 mm max hole 2"/51 mm iii I- II � min hole I' II pi A See Chart �■b � � , * , _ �, 1'1 • _ ` � ' - 11111 � �Jb , Max 3 ,7 f / : �79 mm Clearance / III 31/2783 mm F 2'/ "/ \ 311/16 " /�I 58 mm iir 94 mm � 1 : 11 ' 1 ' ��f i w�iloD 7 0 y y ill , „, 23 MITI 1 / I '' < "/ mm \ rir 111 32 " /13 mm 4 -I / "/45 mm Typical ceding .- -.. 1/4 WARNING: tile - typical Ilru shed ceiling face - �. -.- Typical hat furring channel and ceiling Typical 16 1 /406 mm - 21V161/ _� shown Variations of channel and ceiling 247610 mm OC 74 mm may be used but may result in dimensional V2708 MAX. EXTENSION changes from layouts clepicted in this V2708 1/2"/12.7 mm MAX. RECESS submittal and or iii ipropei lit NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical hat furring channel installation and the corresponding minimum clearance dimensions if no 90° bend is imparted to the hose Hose Clearance Chart VII P17;''' > C[ '�, s _1•_T . is �. Min 6 152 Max 6 A1 165 • www victaulic.com V VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED aOtallJllC` REV_I 10.85_13 FIRE PROTECTION PRODUCTS - FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQB Braided Hose Assembly • HAT FURRING CHANNEL INSTALLATION FLEXIBLE DROP ASSEMBLY, SHORT ELBOW WITH CONCEALED SPRINKLER - 11/2 / 1' "/ �_ Smm38mm 2 "/�e /68 mm („---- / iIiIIIIIII 2/s " /60 rmm d min x hole ole A SeeChait A — III •I — ®i11 6 • m ) . r - 3 / ' / '1�.� " /83mm 58 � , Max —. Clearance 2 "/ 31/4 mm . � , I I. 1 -1k02' 11 79 mm y x / : ; ' / 23 mm lailIVIII WAR N ' / � /1 mm Typical finished Yz "/13 mm 3 / / Typical Hat Furring Channel and ceiling Typical ceiling tile ceiling face 78 mm shown Variations of channel and ceiling Typical 16 "/406 mm — V3802 MAX. EXTENSION may be used but may result in dimensional 24 " /610 mm OC changes from layouts depicted in this V3802 1/2"/12.7 mm MAX. RECESS submittal and /or irnpioper fit NOTE Hose is permitted to be bent in alternative configuiauons What is shown is a typical hat furring channel installation and the corresponding minimum clearance dimensions if no 90° bend is imparted to the hose Hose Clearance Chart It. it ' ,k , , ,, r3.1.4, Min 133 A Max 51/2 140 • .. www.victaulic.com VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED ictaullc‘ 10.85_14 REV_I • G FIRE PROTECTION PRODUCTS - FITTINGS 10.855 AquaFlex Stainless Steel Sprinkler Fittings • SERIES AQU Unbraided Hose Assembly SUSPENDED CEILING GRID FLEXIBLE DROP ASSEMBLY WITH RECESSED SPRINKLER - 1 /z" ADJUSTMENT %Or R See Chart T 0 2 " /64 mm U/a "/222 mm Nom ID A ........ min straight �C See Chart section befoie OA bending o um IA w ____ - -- - - - - 2% /60 mm rP 0 a� til= r z am ii: 3' /d'/ 80 �2 /51 mm -- � '11 mm min hole 2 / — _ — _ _ _ ____ 60 mm ___ R .' '417 � _; j= 3 98 mm * I 6 i v L�j !! ' :t h "/13 mm ` \N ,�. �+®�°.> iii, 1` ' o ,.��'.�_ 11 1/ ' 1 '/4 "/32 mm rill l,,l 1 k "/13 mm Ne 13/4 " /45 mm WARNING: Typical ceiling ��. Typical T -bar grid and ceiling tile Typical finished ceiling face - tile shown Variations of T -bar 24 "/610 mm or 2 " / 74 > and tile may be used but ` 48 "/1219mmOC ' mm may result in dimensional changes from layouts V2708 1/2"/12.7 mm MAX. RECESS V2708 MAX. EXTENSION depicted in this submittal NOTE Hose is permitted to be bent in alternative configurations What is shown is a typical 1 -Bar installation and the corresponding minimum clearance dimensions if one 90° bend is imparted to the hose n Hose Clearance Chart R Minimum 4 I Bend Radius 102 A Min 111/2 292 www.victaulic.com ■ VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED �Ot21Ul1 Cw REV_I 10.85_15 FIRE PROTECTION PRODUCTS - FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings SERIES AQU Unbraided Hose Assembly SUSPENDED CEILING GRID FLEXIBLE DROP ASSEMBLY WITH CONCEALED SPRINKLER - ' " ADJUSTMENT la, Chart See Ch �'% N �C N 1 '/z " / __ P/ / _� �� X 37 mm 39 mm 2Vz "/64 mm �� min straight section �� before bending v A See Chart Oen 01 WARNING: Iv ■11■1 Typical T -bar grid and ceiling tile shown Variations ofT -bai and tile may be used but may result in dimensional changes from _s layouts depicted in this submittal _ 2'Y6 " /68 mm max hole E_ _ 2 °/60 mm "_ � — =•� � � i ll � � � � min hole 0 8 0 m m • 0 _ � / 60 in F0) I1� * , I ll _ __ _ II ilp I I 111 '� iamb :�� / ip1 i ,, !, 1'/2''/ mm 1, ._ IN IIl a 1 � F * I -- --- '/2 " /13 mm Typical hnished 1, " „ Typical ceiling the 24 ^/610 mm or ceiling face . 3/ / 48 "/12.19 mm OC 78 mm V3802 1/2"/12.7 mm MAX RECESS V3802 MAX. EXTENSION NOTE Hose is pei milted to be bent in alter native configurations What is shown is a typical T -Bar , installation and the corresponding minimum clearance dimensions done 90° bend is imparted to the hose 6 Hose Clearance Chart ; :iai ..y -i s s R Minimum 4 Bend Radius 102 A Min 13 V. 333 www.victaulic.com VICTAULIC AND AQUAFLEX ARE REOISTCRLD TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED A 10.85 REV_I • • Q FIRE PROTECTION PRODUCTS — FITTINGS 10.85 AquaFlex Stainless Steel Sprinkler Fittings FLEXIBLE HOSE IN -PLANE BEND CHARACTERISTICS ONE BEND TWO BENDS THREE BENDS Minimum 2X 2X Minimum Minimum Minimum bend radius 2X radius bend radius ( bend radius ■n° 1 � OR OR Minimum Minimum bend radius bend radius ' Minimum bond radius Minimum bend radius \ MMrnrrmm -/ bend radius Note For out -of -plane (three - dimensional) bends, care must be taken to avoid imparting torque on the hose www.victaulic.com VICTAULIC AND AQUAFLEX ARE REGISTERED TRADEMARKS OF VICTAULIC COMPANY © 2011 VICTAULIC COMPANY ALL RIGHTS RESERVED jictaulad REV_I 10.85_17 a= = s t v"'., t "=1 ?R'c AquaFlex Stainless Steel Sprinkler Fittings MATERIAL SPECIFICATIONS Corrugated Flexible Hose: SS304 Adapter Ring: SS304 (Series AQB), Nylon (Series AQU) Seal: EPDM (Series AQB), Nitrite (Series AQU) Nut and Nipple: Zinc- Plated Carbon Steel Reducer (' or 3/41: Zinc- Plated Carbon Steel 90° Reducer (' or 3 /4 "): Zinc- Plated Carbon Steel Braid and Collar: SS304 Bracket Stock Bar Zinc- Plated Carbon Steel End and Center Brackets: Zinc- Plated Carbon Steel Staked Center Bracket Wing Nut: Zinc- Plated Carbon Steel End Bracket Screw Zinc- Plated Steel Optional Tamper - Resistant Screw: Zinc- Plated Steel MODEL NUMBER CORRELATION ., Series AfiB :.... •r.. r: ;> %0 - Ala: iNkiA4444o0161441&11kAi AFB31HLD 3r(AQB3IHLD) AF 31H 31" (AQU -31H) AFB36HLD 36" (A0836HLD) AF -36H 36" (AOU -36H) AFB48HLD 4 8" (AQB48HLD) AF -48H 48" (AQU 48H ) AFB6OHLD 60" (AQB6OHLD) AF -60H 60' (AQU -60H) AFB72HLD 72' (AQB72HLD) AF -72H 72 (AQU-72H) AFB31TLD 31" (AQB3ITLD) AF -31T 31" (AQU -31T) AFB36TLD 36 "(AQB36TLD) AF -36T 36'(AQU -36F) _ AFB48TLD 48 "(AQB48TLD) AF -48T 48" (AQU-48T) AFB6OTLD 60'(AQB6OTLD) AF -60T 60" (AQU-60T) AFB72TLD 72(AQB72TLD) _ _ ' AF -72T 72 " (AQU -72T) WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details 4 NOTE This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations For complete contact information, visit www victaulic corn 1085 5839 REV I UPDATED 09/2011 ✓ctaullc° VIr'IAu lc AND AONACi CX ARC RCCISi Du A, I RMrMARKS f,UMI'AN'/ it /u1l Vi ;IAN IC COMPANY Al 111(1115 10.85 �w P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 inch pipe 1/2 8 3/4 inch pipe LISTED FOR STEEL /CPVC 5 thru 8 inch pipe NFPA 13 UL 1 WT 5 WT. , -250 TEST PIPE ROD LOAD 1 3/8 30 75 403 75 750 1 1/4 3/8 43 95 469 75 750 1 1/2 3/8 54 15 520 75 750 SIZE - ROD- 3/8" or 1/2" 2 3/8 76 95 634 75 750 SIZE - SYSTEM PIPE - 1/2" thru 8" 21/2 3/8 11835 84175 850 MATERIAL - Carbon Steel, Mil. Galvanized to G -90 spec. 3 3/8 16230 106150 1050 LISTING/APPROVAL - 4 3/8 24600 148000 1500 5 1/2 349 45 1996 75 2000 Ui us 203 -EX 2551 1 "- 8" u9n:o 6 1/2 47635 263175 2650 <> Approval guide -I " -8" 8 1/2 71100 380500 4050 OSHPD OPA -0601 Sec Website CONFORMS WITH: Federal Specification WW- H -171E, Type 10 Manufacturers Standardization Society ANSI /MSS -SP -58 Type 10. MAXIMUM TEMPERATURE - 650 ° F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and PIPE A B the CPVC or copper pipe manufacturers instructions. 1 8293 25259 FEATURES - 11 /4 21382 27850 112 22673 29140 * Sized and listed exclusively for use with #310 Surge Restrainer. B 2 26048 32516 * Band edge is offset for EASY pipe insertion A 21/2 34929 41159 * 3 Custom fit swivel nut for better retention in ring. 3 7945 4 4311 WII ORDERING - Part #, pipe size. + „ 43592 49992 � 6 60668 58180 ' 8 75768 83298 11/09 I : < » ^�i ;- �;:''� f . .fir. " "�;,' " ,- ; " °.� S x '. e ; . rn' ��;2e , r E, �y i nr 4• b. eR Y`> ''YZr '3� y „<y a f ' Sqq�� ✓ 4. �� �� - M , r Y . r�'F • R < 'C% BN ` r � g b crW, @ { Yi . ., s 4 c Si4MMYS FOR "NCRETE Vertical Applwcatrong w .. ' is - 3 _ � ' Application Product Features r ? _�..,,s_� - . � ., :.�:.. �. - � °• ' •Easy two step process (Dell hole & "§ . wry. ' ,- r = ; ∎',,=i • drive Sammys concrete anchor) ,� %d' pre - drilled pilot hole regwred , % , Concrete Instal To available fo i . a pro cess ;.:7:2;;:!1::iiiiiiil:::: `' `� a one t o ol Installation pro = G ,,,, - "y a 3_ :.a �trJ� r 9 �y r , Made in theU.SA • ,„4,. r - y PS r a ", , „ .�. . y r ; 1.• _mow _ U , 7 ,., i i l 3I � �. i zi '.1f,, I :s■ :i. .r - r,s s s - , Watch a video demonstralron a( www.itwbuddex.com 3 nt r ' Rod+ Part i { b s, Screw Ultimate FM Test Box ' Approvals Model c x Sae Number 5 Degcdpbons Puliout(Ibs) iLoad(Ibs) Q t fi VERTICAL MOUNT -q f #14 Black 4' 7 CST 200 5 11 6 x 1 2400 25 125 a• k` Nut Driver " ,: .- #8113910 : .m G a d . � � :•:, fi•t 2 X12 E 3tB " 805895 CST 20 5116 x- :1?3 14 " "� 2406::8 • . 14 5= 5. ••, , , r = Part v; = ...,�. - ,,, »,» , Iv� _.. _ �'; ".. x�i..- . .. „, ,rc. ,. , ,gy a 318' 8145925 C S T 39,,,t.- SS 5 11 6 x 1 31 24 25 125 #14SW Red N,. m :: ` Part X112 , 8060925. s V 2 5 ;; V- Vagili; �, CS 2 5 t1 6 �c - 24 0E3 - = 2 5 � Part # 8114910 „� �� a.. '�' am e _ _ � � 0� ' " e _ _ _ - . . ,�`u.. ..�. � ,< . �-�• 1 < <,;..'s ' Tested m 3000 P51 concrete S/DEWINDER FOR CONCRE TE Hor on ta l A '' %►cat a .,,+.»td�u .. �� e ; r,. --�. �, - -, ;7, - °`' mss V... 4 jl e.., v a x t ii Application Product Features s ' } Easy two step process (Drill & drive Sammys ' 1 , ^f ' ' f cf 5 s ° r concrete anchor) ' € s � GI rF Va " pre - dulled plot hole required .. > ' t.;f s I , c a Concrete Tool available for a one tool MA WIiH I r mstallabon Installation process k� e i aE _ "C • Made in the U.S.A. , C ' u ,i d K i Y Watch a video demonstra o ar; . www.rtwbuildex.cm 1 y l Approvals �? x Sae Number ;Model Descn ons Pul bs L (Ibs Q X, r + q v NORkii,i4 L MOUNT _ �� = , s 1/4" 8062957 SWC 200 5116 x 1 314 2450 25 125 >a s so-s; :. ,'' ":318': , -- - 6NC 20 V =5 .., ,. " `.�, , ;';�a••=•. "`:``' " . ;' .24 5 0;.' =; .: .:..;x;:1 `' «x,., 25 '= < - "" 125 trisiiiiitifilii £ #145W Red *Tested in 3000 PSI concrete Nut Driver ti Part # 8114910 k @ SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe Installation k oHS each time When the face of the driver comes into contact with the material you are installing in o, continue drdting until nut dnver spins MADE IN U S A `s ^' free Installation is then complete Warranty requires the use of the appropriate nut driver for installations . :'.�, ry v a r t ' g " 3 r, a ' `. �, s 4 W s'H"a '�- .,.,.. .'--- v ' : ,,- , 5g ,. y a 5: . i.,.. 1`,4 :.+ + 5 R � a '?a` -r :-� e '' f n'�vf i nv, I s 5 2I' i t i. a' `, -' 3,: ^rC: ;a :, ' v r . W i d am' e 4::: i '� i '`'$ a s : h , 1 t w "' i- r t a 'k. 4 3- R ,� t•r i P r "- .�. _ . c � �. � r t : � . ry r F d r a: �,'%- .. a y _ , a, �h . For the m ost up to date Informatio visit ww Itwb coin ra,y ""10 I E` t i11.'i x, i as a a 4wo- S f,�i .:w _ •7 _ . _ � 4 ,x x5- 'a �.`� �`r.:n .__._ .�_rt a ; ,a # - :., , t v z - �' .I - rrtS -k8�, .. k i i , a.�, ` x... y y -# _ .- t { -+` �. , 1 9. s . s - 't t t .. 3 .+h _ , S; 'k1 �k ,y s <,? ,d� s' : k -4k:- » -, � . °ate .m , t. _ ... to .. , =a - SEE GENERAL N ❑TES FOR DESI CRITERIA ' '_ H ��j���, } u CONCRETE OIL -,"` �_ n :jr'' IC= m; E "l t . 1 ^ _ _T EWJ i'z F CL E F IC I L°3: F :L:L CENTER, g' 1" 6' 6" 8' 6" 4' -4" I 6' -11" OCT 1 7 201 QUARTER 1 TYP. • IF❑W HEADS IN I.F.O.W. LF❑W . .. °_ I.F.D.W. ; 1 EXIN , ® 1 I 1 r , CITY O� 1 �p META DEC KING �� BUIL�I�IVISI�N ACT IST TYP.G . 1-6 1 1 1 0-10 3 - 4 ' 6 - 9 I N = G �� T SEE SAMMY VERTICAL co - ° NFPA 13 AFCON BAND HANGER PIPE — 1 a, I 8.6.3.2.4 6' -7" , 13' -3" 1 t t 0 - r--• / I.F.❑.W. , , 1 -0 1 -0 1 -0 r 7 ' , i m , 1- o 6 9 CENTER, 1 1 7 C} 1 1 p .J � ' , k QUARTER = HEADS IN EXISTING __ jr 1vY VERTICALL HANGER 1 ACT. TYP. t( TYP. < o o � - r ) o I 10 ,_.� 1(„1: �� / 6' -3" 16' -0" , 5' -4" ) 1 TYPICAL 24" AQUAFLEX I.F.D.W. I.F.O.W. 1 0 SERIES UNBRAIDED ', \ '. \ ,s \ FLEX CONNECTION REPLACE SEE _ 1 1 r K 1 t EXISTING t d NFPA 13 1 -7 0-- 1 l t - t o 90° W 1 -0 CENTER, m 8.6.3.2.4 FIRE \ / NEW TEE 1 QUARTER SPRINKLER L ` RECONNE , HEADS IN BRANCHLIKE, 3 1t;t ^ ^ -co ^ /MAIN 1 ; ^ EXISTING 1 0 AQUAFLEX T BAR GRID i :: + CONNECTION BRACKET ACT. TYP. 1 ED 7 2 2 ,.,,•_ . _,, ,,.�.,,.,..,,., 2w,.«,2 ».w... N 2 � 2 2 2 II: . -r APPROX. LOCATION OF 0 -6 8 -8 - 7 7 -4 2 -8 �9 -11 n -r —. EXISTING 2Yz" MAIN g 1 ,, " 1 7 SEE • -°® t 0 1 0 NFPA 13 "��1,0 AREA J >- 8.6 3 2 4 A.0 T. RECESSED AUTOMATIC COVERED i 7' -3 10' -0" 2' -8'�� 1 CEILING SPRINKLER LOCATE AT I F.O.W. "'0 1 -0 CENTER /QUARTER OF TILE BY C❑RRID ❑R COVERED BY TYPICAL EXISTING EXISTING SPRINKLER SYSTEM. } AREA COVERED BY EXISTING FLEX DROP DETAIL 24 " SYSTEM LINES TO BE CONNECTED TO sf' SYSTEM -- ',1: -- IC> EXISTING 1Y2" OUTLETS = PROVIDED IN C ❑RRID ❑R MAIN, BUSH ACCORDINGLY OR L CONTRACT NAME: PR ❑VIDE NEW OUTLET. % `1 i 1 PLAZA WEST, 5TH FLOOR T.I. 1 i / 9600 SW OAK STREET .III FIRE SPRINKLER PLAN -5TH FLOOR, SUITE 500 T.I. - -- TIGARD, OR 97223 . �� 1/8 = 1 -0 0' S 10' 20' / CONTRACT WITH: = ■IIImi, SUITE 500 AREA OF NORRIS, BEGGS +SIMPSON NOR T H WORK: 2,840 SQ, FT. 121 SW MORRISON, STE 200 06 PLAZA WEST PORTLAND, OR 97204 Ea PLAN 5TH FLOOR / PROJECT MANAGER: BEVERLY FOSTER .■ NOT TO SCALE 17,300 TOTAL SQ. FT. PHONE: (503) 352 -8113 NOR T H � '1 re Systems West SYMBOLS GENERAL NOTES SPRINKLER HEADS 1 G 600 SE Maritime Avenue, Suite 300 SYMBOL DESCRIPTION 1. ALL MATERIAL & EQUIPMENT TO BE NEW & UL OR FM APPROVED. �!, EXISTING FIRE SPRINKLER MAIN 2 DESIGN, FABRICATION & INSTALLATION SHALL BE IN ACCORDANCE M11H NFPA /13 2001 EDITION SYM. TYPE MFG /MODEL SIZE TEMP. FINISH CANOPY QUANTITY 1r_= :€ " Vancouver, WA 98661 3 PIPE HANGERS AND METHOD OF HANGING SHALL BE IN ACCORDANCE MTH NFPA /13 2007 EDITION (360) (360) 693 -9906 far (503) 289 -2208 NEW HANGER LOCATION 4 ,PINING OF PIPE AND FITTINGS SHALL BE IN ACCORDANCE WIN NFPA /13 2007 EDITION ® PENDENT RELIABLE F1FR56 RA1414 1/2" 155* CHROME REC. CHR. 23 ru CENTER- CENTER LENGTH OF PIPE 5.PIPING LENGTH DIMENSIONS SHOW CENTER TO CENTER CUTS 6 SCREMED PIPING TO BE BLACK SCHEDULE 40 PIPING W/SCREMED CAST IRON FITTINGS WA ST, CONTR LIC NO: FIRE SWI 14081 OR ST. CONTR LIC NO: 49732 7. PIPE SIZING ACCORDING TO EXISTING DESIGN CRITERIA AND PREVIOUSLY APPROVED FIRE SPRINKLER I DESIGNER DATE JOB NUMBER SHEET SUBMITTAL FOR EXISTING BUILDING (CITT OF TIGARD, BUILDING DIVISION, NOVEMBER 21, 2008) 0.10/900 SOFT., LIGHT HAZARD OCCUPANCY SAFETY MARGIN OF 15.1% ON 5TH FLOOR CALCULATION. TOTAL THIS PROJECT 23 B. CULLINANE 10/3/11 271118 1 of 1