Loading...
Correspondence C T E N G I N E E R I N G PLLC 180 Nickerson St Suite 302 •t,'�. ' r� . ti 981Vy (20(4285-1512(V) JUL 21 2006 (2.06)285- 061€(F) CITY Ut 20 July 2006 Dana Hunt Potygon Northwest 109 East 13 Street OFFICE COPY Vancouver, WA 98660 Re: Canterbury Crest (a.k.a. Canterbury Woods) SW Canterbury Lane, Units 101 and 102 id gY Dear Dana, We understand that there was a broken gas line and subsequent fire on the Canterbury Woods site in Tigard, OR. The location of the fire was at the northern corner of building number 3 near the patio and deck of unittypes 0 and Dl. We have reviewed the photos of the post -fire condition of_units D and D1 at building #3. It appears that_the_damage to structural members is limited to the exterior of the deck area of Unit D1 over the Unit D patio. Structural framing members and sheathing showing char will most likely require replacement. We recommend that the rim joists, deck beam, beam hanger, and a portion of the ledger be replaced. We should be notified if additional fire damage Is discovered. We also recommend that the membrane installer review the deck membrane, the building wrap material, and any flashing We trust that this letter along address your concerns and provides adequate direction for repairs. Please phone if you have any questions_ Sincerely, Todd R. Eaton PE CT Engineering • Structural Engineers ■,4,<