Loading...
Plans BU P2009-00062/M EC2009-00156 PANDA EXPRESS 46230 SW PACIFIC HWY 100 City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 r r ® April 21 2009 � ® Reiter Design Group Architects 7965 SW Cirrus Drive Beaverton, OR 97008 RE: RESTAURANT TENANT IMPROVEMENT Project Information Building Permit: BUP2009-00062 Occupancy Type: A2 Mechanical Permit: MEC2009-00156 Construction Type: VB Tenant Name: PANDA EXPRESS Occupant Load: 53 Address: 16230 SW PACIFIC HWY Stories: 1 Area: 2,100 SQ FT Sprinklers: YES The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition, the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The submitted plans are approved subject to the following. BUILDING • All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC • Exit doors shall be provided with panic hardware.1008.1.9 OSSC Exception: Main Exit Door. • The main exit shall be provided with signage indicating"THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" Section 1008.1.8.3 OSSC • Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 1/2 hours of illumination in case of primary power loss. 1011.5.3 OSSC FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. • The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1006.1 OSSC Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard-or.gov • TTY Relay: 503.684.2772 • Provide one 2-A rated fire extinguisher in the new area. The extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguisher. Standard 10-1, Chapter 3 TVFR99-01. • Deferred submittals such as Fire Alarm, Fire Sprinkler,Truss Joist Shop Drawings, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. Deferred items; • Hood Suppression System •'• Fire Sprinklers MECHANICAL • The piping system shall be tested at 10 pounds per square inch for not less than 15 minutes with no perceptible drop in pressure. C406.4.1 OMSC • Ductwork shall be supported in accordance with Sheet Metal&Air Conditioning Contractors National Association, Inc. (SMACNA) • Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room and within six feet of the appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC • Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC • Permanent equipment supported by the structure, 400 lbs and over, shall have their attachments designed in accordance with the Building Code. 301.16 OMSC • Appliances shall be accessible for inspection, service,repair or replacement without removal of permanent construction. 306.1 OMSC • Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC • Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC • Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer,Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information,please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and pro essing the documents. Respectfully; ) /7/ ,BBinn Bla194 Building Official This form is recognized by most Building Departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. IN BUILDING DIVISION T I G A R D TRANSMITTAL LETTER a TO: DATE RECEIVED: DEPT: BUILDING DIVISION FROM: COMPANY: PHONE: By: RE: (Site Address) (Permit/Case Number) (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: Fees Due: ❑ Yes C No Fee Description: Amount Due: Special Instructions: _ Reprint Permit(per PE): — Yes ❑ No fl Done Applicant Notified: Date: Initials: T:\Building\Forms\TransmittalLetter-Revisions.doc 4/4/07 _._ _ _ _ _ _ _ _ GENERAL FINISH NOTES PROJECT DIRECTORY . • * "- . • • • 1. ALL SURFACES TO RECEIVE PAINT FINISH SHALL BE PREPARED TO SHOW NO DEFECTS. - _ _ A. APPLY ONE (1) COAT PRIMER-SEALER. LANDLORD PANDA EXPRESS APR 10 2109 B. APPLY TWO (2) COATS FINISH. NO STIPPLE FINISH ON ALL PAINTED SURFACES. SEE SCHEDULE ON PLANS FOR COLOR TENANT COORDINATOR/ OWNER �, - AND TYPE. LANDLORD'S REPRESENTATIVE CI 0 TIC PANDA RESTAURANT GROUP,INC. _= 17 MARY ANN KOLEN ILDIG DIV ION O 1683 WALNUT GROVE AVE. U �C 2. ALL INTERIOR GYPSUM BOARD TO RECEIVE PAINT FINISH SHALL BE TAPED, SEALED, AND SANDED TO RECEIVE FINISH. GYPSUM HARSCH INVESTMENT PROPERTIES ROSEMEAD,CA 91770 _ BOARD UNDER FRP OR STAINLESS STEEL SHALL ONLY BE FIRE TAPED AND SANDED. ALL INTERIOR GYPSUM BOARD TO BE 1 121 SW SALMON STREET,5th FLOOR iiiiirl____ _ _.__ IIP TRUE AND LEVEL. TEL. 626-799-9898 (f) PORTLAND,OREGON 97205 {' FAX. 626-372-8288 (� TEL. (503) 242-2900 t 3. GYPSUM BOARD SHALL EXTEND AT MINIMUM OF 6" ABOVE LAY-IN CEILING SYSTEMS OR UP TO GYPSUM BOARD CEILING. FAX. • • JERALD EARL, PROJECT MANAGER • p GYPSUM BOARD ON DEMISING WALLS SHALL EXTEND TO THE STRUCTURE ABOVE UNLESS OTHERWISE NOTED. 16420 SE McGILLIVARY SUITE 103-353 4 VANCOUVER,WA 98683-3461 G::4. ALL GRILLES SHALL BE PAINTED TO MATCH THE CEILING OR ADJACENT WALL FINISH. TEL. 360-210-5248 a JURISDICTIONAL AUTHORITIES MOBILE 360-936-2482 'A �c° 5. ALL FLOORS SHALL BE SMOOTH AND LEVEL WITHOUT DEPRESSED OR RAISED AREAS, EXCEPT PROVISION SHALL BE MADE TO lc:::)1N BUILDING DEPARTMENT FAX. 626-372-8865 �`7, � HAVE SMOOTH, EVEN SLOPE TO FLOOR DRAINS. THE SURFACE SHALL BE ACCEPTABLE TO RECEIVE FINISH. CITY OF TIGARD CHINE 6. VERIFY AND COORDINATE THE LOCATION OF ALL WALL OR CEILING ACCESS PANELS WITH THE ARCHITECT. 13125 SW HALL BLVD. TIGARD,OREGON 97223 ARCHITECT 7. PROVIDE METAL CORNER BEAD, TRIM AND CASING FOR ALL EDGES AND CORNERS OF GYPSUM BOARD SURFACES ON PAINTED TEL. (503) 639-4171 SCOTT A. REITER WALLS. CLEAN GYPSUM BOARD CORNERS WITHOUT METAL CORNER BEADS SHALL BE UNDER FRP, TILE, OR STAINLESS STEEL. REITER DESIGN GROUP ARCHITECTS, INC. PANDA EXPRESS INC. FIRE DEPARTMENT 7965 SW CIRRUS DRIVE 8. PROVIDE STIFFENERS, BRACING, BACK-UP PLATES, ETC. AS REQUIRED AT STUD WALLS FOR SUPPORT OF FIXTURES AND OTHER \ TUALATIN VALLEY FIRE BEAVERTON, OREGON 97008 & RESCUE TEL. 503-574-3036 1683 Walnut Grove Ave. EQUIPMENT. \ 20665 BLANTON STREET Rosemead, California On ALOHA, OREGON 97007 FAX. 503-574-2916 9. ALL EXISTING SURFACES SHALL BE INSPECTED AND ALL NECESSARY PREPARATORY WORK SHALL BE DONE IN ORDER TO • TEL. (503) 649-8577 Telephone: 626.799.9898 RECEIVE NEW FINISHES. `) MECHANICAL, PLUMBING, ELECTRICAL Facsimile: 626.372.8288 HEALTH DEPARTMENT 0 10. BEFORE PAINTING OR FINISHING WORK IS TO BEGIN, ARRANGEMENTS SHALL BE MADE FOR PROPER VENTILATION AND LIGHTING BRUCE MEYERS Q IN ALL AREAS. OF HEALTH &N COUNTY SERVICES SYSTEMS DESIGN CONSULTANTS,INC. 1515 SE WATER AVENUE,SUITE 400 155 N. FIRST AVENUE,SUITE 170 PORTLAND,OREGON 97214 11. ALL FLOOR MATERIAL CHANGES SHALL OCCUR AT DOOR CENTERLINE UNLESS OTHERWISE NOTED. �i HILLSBORO, OREGON 97124 All ideas, designs, arrangement `'' O TEL. (503) 248-0227 9 and plans indicated TEL. (503) 846-4402 { j or represented by this drawing are the property of FAX. (503) 248-0240 Panda Express Inc. and were created for use on 12. FLOOR MATERIALS SPECIFIED ON THE FINISH SCHEDULE SHALL EXTEND UNDER ALL EQUIP. AND COUNTER AREAS. this 1 h s spec fic project. None of these ideas, designs, ELECTRIC UTILITY arrangements or plans may be used by or disclosed to any person, firm, or corporation without the 13. FLOOR CONTRACTOR SHALL SUBMIT TO OWNER THREE COPIES OF MANUFACTURER'S MAINTENANCE MANUALS FOR THE FLOOR PORTLAND GENERAL ELECTRIC written permission of Panda Express Inc. MATERIAL INSTALLED. 121 SW SALMON STREET • PORTLAND, OREGON 97204 1.� 14. ALL TILE SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN THE HANDBOOK FOR CERAMIC TILE C H I N TEL. (503) 228-6322 INSTALLATION OF THE TILE COUNCIL OF AMERICA (CURRENT ADDITION). 15. ALL INTERIOR FINISHES SHALL COMPLY WITH APPLICABLE LOCAL CODES AND REGULATIONS. WATER AND SEWER REVISIONS: TIGARD PUBLIC WORKS DEPARTMENT 16. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ADEQUATE SURFACE CONDITIONS THAT EXIST FOR THEIR WORK. IF TIGARD TOWN SQUARE 8777 SW BURNHAM STREET A TIGARD,OREGON 97223 n ADEQUATE SURFACE CONDITIONS DO NOT EXIST THE SUBCONTRACTOR SHALL NOT PERFORM THEIR WORK UNTIL THE CONDITION 503 TEL. 639-4171 IS CORRECTED. ( ) 17. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. GAS COMPANY IP A NORTHWEST NATURAL GAS A 18. ALL TILE DIMENSIONS ARE DESIGNED TO LAY OUT IN AN EQUAL MANNER. IF TILE MUST BE CUT, THE GROUT LINES SHALL 220 NW 2nd AVENUE n ALIGN WITH ADJACENT TILES OR BE CENTERED AND CUT IN OBVIOUS LOCATIONS. THE GENERAL CONTRACTOR SHALL PORTLAND,OREGON 97209 COORDINATE THE INSTALLATION OF GYPSUM BOARD WITH TILE DIMENSIONS TO PERMIT EVEN INSTALLATION. TIGARD ,. TEL. (503) 422-4012 GENERAL NOTES VICINITY MAP N.T.S. PROJECT INFORMATION ISSUE DATE: q �..:� -.,_i�-��. 'f-`�i�.-j �i f:- }�(-:.mss ti � .f� -.5` 'r'JX _ �...ii +Ill _ 1. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FULLY EXAMINE THE TENANT SPACE. ALL EXISTING I r l -_- "" %, ,, -f � . d Y ;, , ;'.r° I �,>.,, _- ,m �, rc ` ' 1ST PERMIT APPLICATION 01/09/09 :f 1 ( -'; � ' -.,.L_?r e ,,t� » 1[.:..,, v 4 it r_..__,� j x, �� :\ii=4:71, 12tT `,�STRUCTURES AND ALL OTHER EXISTING STRUCTURE ON THE PROJECT SITE BEFORE COMMENCING THE WORK. GENERAL � .:-:::;��-�=-;�-�:-�-_�, �, r � �, . _;;, �{ �, --,r -,�-.� � N.� dD � �i ;. �' ',, �, � �- 3 I :l a, �; , _ .sVV�t 'ti's , 2ND CONTRACTOR SHALL VERIFY ALL DIMENSIONS VERTICAL HOR r ." �r -- 1 ° 4 "•�,::,,;,`- 1`t ,9 -= 7.71 °� - ' w.' 1 l `- �; APPLICABLE CODES: ALL WORK UNDER THIS( IZONTAL AND OTHERWISE), AS WELL AS TO VERIFY THE CONDITIONS . ,, 'I fi / I ; CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE AND NATURE OF THE TENANT CONSTRUCTION MATERf 1 i t ��y `; -« ''' .t r z __ tig ' +�= =__ ,� . SPECIFICATIONS AND DRAWINGS AND SHA 3RD ALS, AND AVAILABLE UTILITIES AND STRUCTURAL ELEMENTS AND TO NOTIFY ( ry � mgt a {• - - / �_ __ r e LL SATISFY ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS OF r 1 -,-r- 11 ''-_ ,: j( `�A 3'D:� 1 :-ic..�i �, ' i - 1 - 1) * :!`^ J iJ--"t.C--1 ri -, `^ - (i --'••``THE OWNERS REPRESENTATIVE, IN WRITING OF ANY AND ALL DISCREPANCIES BETWEEN THE SAID EXIS ="� '` �Y. �� =� 1 .. �`, ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE 4TH TING CONDITIONS AND _� � ___ _lI 1 --� ?� I? " _ .� _----I " WORK SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR INVOLVED. APPLICABLE CODES INCLUDE, BUT 5TH THESE DRAWINGS. FURTHER, IT SHALL BE THE JOINT RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL ;, a` -' ' , , a;ice �. / l i J-1,l f 1= b, II j - '„ '` .7-w._= _ 4 t-' tiles i t .,,^�'__`(.. -9 �r ii' ;6.SUBCONTRACTORS AND SUPPLIERS OF MATERIALS TO SECURE ALL NECESSARY ADAPTATIONS TO SAME AS RE UIR lY,� '';� r iI �`, tip _.-.1 _ I .= - -, ,,_4_Y, ARE NOT LIMITED TO THE FOLLOWING: Q ED FOR THEIR u : _ 7:_-- - - e n RESPECTIVE WORK PRIOR TO ORDERING, FABRICATION OR INSTALLATION OF ANY MATERIALS E UIPM _ y I ! T "- ='�-° -`1 ' _.w � ' -�" 1 '� � L.___' _ . 6TH EQUIPMENT OR COMPONENTS WHICH l-, . =_.-__- - �-(- i _ ,. f/ '. ._.,.� = - �� ' �;i-�---'` _if � 1� � t; .�= � u...� ,\:.=..^ it � `--- 6 _ i ��-- -_i rnf7,41;i1 ARE TO BE INTEGRATED INTO THE WORK OF THIS PROJECT. NO CLAIMS FOR ADDITIONAL COMPENSATION SHALL BE MADE OR _,_:,i j_ I, V >� ., ,� ` " _° !;` Vi____It K. }�, ! I CODES SHALL BE VALID UNLESS WRITTEN NOTIFICATION IS RECEIVED BY THE OWNER'S REPRESENTATIVE AND THE ADDITIONAL - �' 1. STATE F` 1 ai �f�' �'� , Il , _ OF 2007 OREGON STRUCTURAL SPECIALTY CODE, COMPENSATION IS APPROVED IN ADVANCE OF PROCEEDING WITH THE - - ; ;. 1 `- ai '' °LL E WORK. -, I __ , , ' 3 ll .r 1° '' ' l' t ' BASED ON THE 2006 INTERNATIONAL BUILDING CODE. 2. COMMENCEMENT OF WORK IN ANY AREA BY THE CONTRACTOR SHALL BE CONSTRUED AS ,� ,y - -� -,�� , s Q c� c� _} 2. 2007 OREGON MECHANICAL SPECIALTY CODE, BASED ON S THAT THE CONTRACTOR HAS CHECKED i�,; p c H � ,s : , __,i,N � :::-- . ( „_ =__3,= „ ;;r 0 THE 2006 INTERNATIONAL MECHANICAL CODE. DRAWN BY: SAR THE EXISTING CONDITIONS AND FOUND THEM TO BE SATISFACTORY TO ACC ` ``' ' ! '� i '' ' � ` ACCEPT THIS PORTION OF THE WORK. 1 _'a- ' 4 � ' __31 ( _ f �._. 'I :�_�.,-1.1---' _-_ -.-,---(4.,)----I�__.,� �, :::' ,t w - �- --,t4 ', �� 3. 2005 OREGON PLUMBING SPECIALTY CODE, BASED ON THE 2003 UNIFORM PLUMBING CODE.3. 4 2005 OREGON ELECTRICAL SPECIALTY CODE, BASED ON THE 2005 NATIONAL ELECTRICAL CODE. ALL WORK SHALL BE PERFORMED AS TO COMPLY WITH ALL GOVERNING STATUTES, ORDINANCES, REGULATIONS, CODES AND i ,.,.--=-"_- � '� :�E�,-w,�,. �;} .� ,%.�-� t� ,; ;,, -. - ,1! �„ � 1�--��l f _�C7,-;.\---1,_- 1#--; � � � :� . ,,r �- I ra //'rL ird ,tr i,,,, .?` -s:� �r Ai 1 5 - $Dfl4= =1 !, f!,_�^{.6 Exrt29:::t `� .. INSURANCE RATING °' "-' C TING BOARDS. NO WORK SHALL CO 4 T ,tt_' - s_: .� ry z�. ! F.,o „ : R,.,, COMMENCE UNTIL ALL GOVERNMENTAL AND JURISDICTIONAL PERMITS AND 1 ._mot a_ �:-;r- " � :C 5. OREGON 2007 FIRE CODE AMENDMENTS, BASED ON THE 2006 INTERNATIONAL FIR E FIRE CODE. ,; APPROVALS t-° �' - �� _ _ _� !I .rMr ,.r..-• LS ARE OBTAINED. , r - �- -= ._.�r 1 'I' 1 f i,.. a, ;I :tF' =f� ;fW 3w lasic#t r; - j $rr--..`_`1I ? + il'r II r•: -; iC '.. `�� f)------A .t%�,' >` �I := ;i BUILDING > - . -�--� ,, 1 1 `''� �� :. _ _�� ,� _ -% '~� G INFO PANDA PROJECT#: S4-09-D2116 4. ALL WORK SHALL BE PERFORMED IN A FIRST CLASS MANNER AND SHALL BE IN GOOD AND USABLE CONDITION AT THE DATE r:~'` '� .. . a.' ` ` �� j!-" . zu r '' :7,/,-; _ ii _ 11 i ,i� i�,-1fIt---:--Lit _� BUILDING I NFORMATION: OCCUPANCY GROUP ARCH PROJECT#: 0821 OF COMPLETION THEREOF. �• -:_s- • - -, d/----17- A 2 1 _'? i - �71 CONSTRUCTION TYPE V-B NON-RATED !� } %i (_ °: � -i 1( l 7f`-c j'i�t� i ? 1 F6 Exit } ii " m ,'r a^ _�'�, I��� _._li��';� a-� - - --•- � ,.-'"� ti{ -�.I�` 290 .. .i_ � � �;Intl�� -,:--'1-----a'�_ � � iti `�I -f--�{��,,��t _��� - � ¢��i �d t!!�+� ;� il FULLY 5PRINKLERED 5• ALL WORK SHALL BE COORDINATED WITH THAT OF THE LANDLORD AND OTHER TENANTS IN THE CENTER SO THAT THE : i 1 d I`,-1 - - I` - �;J-° ; (FULLY SPRINKLERED) N .� 1 CONTRACTOR'S WORK SHALL NOT INTERFERE WITH OR DELAY THE CONSTRUCTION OF OTHER CONSTRUCTION IN THE SHOPPING ,," _ ;;IHL ;Fes.. ITE t �, PANDA EXPRESS RESTAURANT TENANT IMPROVEMENT ARCHITECT:,, CENTER. t' :. ,r_~. �L�, n , >! --->< "' 1 � • - . RESTAURANT AREA: 2095 SQ. FT. .-Ci�i=k'tNitlflf0l'''S *`',,. .---,°i ,r i l "-•ct±- '" - a --, ;, -, -- A ''Y�-'I Ex,l2� 6. CONTRACTORS ARE REQUIRED TO GIVE THE LANDLORD TWENTY FOUR (24) HOURS ADVANCED WRITTEN NOTICE OF SAID WORK. --= a, , ,, ,--1 - . i . -_- -� _ f_� ,_;��p,1R - ?' FURTHERMORE, CONTRACTORS, SUBCONTRACTORS, AND MATERIAL MEN AGREE TO COMPLY WITH ANY LANDLORD it " _ `�- -- ' `� � - B a /. ^ 'c--;! ,� EMPLOYEES: 3 EMPLOYEES SHIFT (2 SHIFTS PER DAY RPG PROCEDURE ,� ? ;I �,'--- ii r ( DAY) HEREAFTER ADOPTED WHICH REQUIRE AND IS NOT LIMITED TO THOSE PERFORMING TENANTS I' = I' i.I `'`! - .:' 1. ''' " - " I � f ,` f ' 1�ENANTS WORK AFTER REGULAR SHOPPING / SIC .__r; - _ i t, �, � SEATING: 48 SEATS CENTER HOURS TO "SIGN IN" AND "SIGN OUT" WITH THE SHOPPING CENTER. - l _..,-.,r._ 4 `, - 2 �t i' ,, 1 r{ � ... , �.-' �- { 't m i, i� °" <° , -;1 [ OUTDOOR SEATING: 0 SEATS '.�a. mil';..3: k3rd St ,,r'"/�`t�%f - dp `� -!1 - _ '-- ►=st;� `� 1 / -7 -- , 'ci_f, 1; ....Y.., REITER DES 1 G N GROUP 7. ALL WORK SHALL BE PERFORMED IN A MANNER WHICH DOES NOT GENERATE NOISE, VIBRATION, ODOR OR DUST WHICH, IN I ( DEFERRED SUBMITTALS - �al�r;��ti ,l' wr>.:Y.{ r Exrt289, :P ... e1»1¢ ARCHITECTS, INC. LANDLORD'S SOLE DISCRETION, IMPAIRS WITH THE OPERATIONS OF THE SHOPPING CENTER OR THE CONDUCTING OF BUSINESS otCommar f fir` w,a 4 BY THE TENANTS THEREIN. ,`,�,:. k 1. THE FIRE SUPPRESSION SYSTEM IS UNDER A SEPARATE PERMIT AND WILL BE A DEFERRED SUBMITTAL. r�^•� 1 -=T�alh 4 7965 SW CIRRUS DRIVE 'fit, i -s' ,,,,..9.,Court r �} BEAVERTON,OREGON 97008 8. - { _004'341' � = � ,. ;�,= , .. (503)574-3036 FAX(503)574-2916 UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR INSTALL OR PERMIT TO BE INSTALLED, ANY MATERIALS CONTAINING j 3 �r. � �f,, x. ASBESTOS WITHIN THE SHOPPING CENTER OR THE TENANTS LEASE PREMISES. 7001 Microsoft Corp_All rights reserved. r- {; 1 1 ,;.; � ?'' '> .. r a,fib► ' 9. ALL WORK SHALL BE CONFINED TO THE PREMISES AND CONTRACTORS, SUBCONTRACTORS OR MATERIAL MEN ARE NOT A PERMITTED TO PERFORM ANY OF SAID TENANT'S WORK (OR STORE ANY MATERIALS OR MACHINERY) OUTSIDE OF THE PREMISES, B B R E�/I AT I O N S SYMBOLS D RAWING I NDEX SUBJECT TO LANDLORD'S APPROVAL OTHERWISE. . STAMP: A PPI D PLANS INCLti ► INATTA►. • II G' 10. NO CONSTRUCTION MATERIAL OR DEBRIS SHALL BE PLACED IN ANY OF THE LANDLORD'S TRASH RECEPTACLES OR COMPACTORS T_1.0 COVER SHEET STRtCTURAL,C. AT ANY TIME. THE CONTRACTOR SHALL ARRANGE (IF REQUIRED) FOR A TRASH DUMPSTER, SIZE AND LOCATION OF WHICH IS T 2.0 SPECIFICATIONS LATERAL CY CS GEORGE T. RQBISON SUBJECT TO LANDLORD'S APPROVAL, FOR THE REMOVAL OF REFUSE. T-2.1 SPECIFICATIONS C") . AFF ABOVE FINISHED FLOOR ID INDIRECT DRAIN D1 DOOR TYPE C1 CEILING FINISH T-2.2 HANDICAPPED NOTES TRUSOv-pjAAL.:73 11. THE ABBREVIATION OF "N.LC." INDICATES WORK AND OR MATERIAL IS NOT IN THE CONTRACT OF THE GENERAL CONTRACTOR, T-4.0 FINAL PUNCH LIST ,` tJ�, R POOREGON HOWEVER THIS DOES NOT RELIEVE THE G.C. OF THE RESPONSIBILITY OF COORDINATION. ALUM. ALUMINUM INT. INTERIOR 2520 1 A-0.1 OVERALL SITE PLAN ,� 12. REPAIR ALL DAMAGE OR VOIDS CAUSED DURING CONSTRUCTION TO ANY AREA OF THE PROPERTY TO THE ORIGINAL CONDITION. BV BALL VALVE (FULL PORT) KEC KITCHEN EQUIP. CONTRACTOR WINDOW TYPE so WALL FINISH A-1.0 FLOOR PLAN/FINISH SCHEDULE PROTECT ADJACENT AREAS FROM DIRT AND DUST. A-1.1 REFLECTED CEILING PLAN/LIGHTING SCHEDULE OF C. CONDUIT LL LANDLORD A-1.2 FINISH FLOOR PLAN 13. ALL CONCEALED WOOD BLOCKING IN WALLS AND CEILING SHALL BE FLAME RETARDANT TREATED. A-2.0 INTERIOR " CO CONDUIT ONLY MC MECHANICAL CONTRACTOR FLOOR FINISH 34 KITCHEN EQUIPMENT OR ELEVATIONS A-2.1 INTERIOR ELEVATIONS 14. ALL FIRE EXITS ARE TO REMAIN CLEAR AND OPEN DURING ALL PHASES OF CONSTRUCTION IF APPLICABLE. CW COLD WATER (N) NEW A-2.2 KITCHEN ELEVATIONS 15. THE LOCATIONS OF EXISTING UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN INDIVIDUALLY VERIFIED A-3.O ARCHITECTURAL DETAILS PAN DA EXPRESS BY THE OWNER OR HIS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES (E) EXISTING NIC NOT IN CONTRACT WALL TYPE 101 ROOM NUMBER BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY A-3.1 ARCHITECTURAL DETAILS TIGARD TOWN SQUARE THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES. EC ELECTRICAL CONTRACTOR NTS NOT TO SCALE K-1.0 KITCHEN EQUIPMENT PLAN DEFERREI, 16. THE TERM "OWNER" OR "TENANT" SHALL REFER TO PANDA EXPRESS AND ITS AGENTS OR REPRESENTATIVES. THE TERM EWH ELECTRICAL WATER HEATER OA OUTSIDE AIR 11� F-1.0 CASEWORK/COUNTER B 1.0 ELEVATIONS STRUCTURAL GRID �� "GENERAL CONTRACTOR" AND "G.C." SHALL REFER TO THE PERSON AND/OR PERSONS WHO HAVE CONTRACTED OR r, E-1.0 POWER PLAN 16230 PACIFIC HWY. SUITE 100 SUBCONTRACTED FOR THE WORK. EXT. EXTERIOR OC ON CENTER E-2.O LIGHTING PLAN Mechanki TIGARD, OREGON Plumbing 17. ALL WALL & CEILING CONSTRUCTION SHALL BE SUPPORTED BY STRUCTURE & NOT BY METAL DECK IF APPLICABLE. FOF FACE OF FINISH PC PLUMBING CONTRACTOR A E-3.0 ROOF PLAN Electric A-2 SECTION POINT OF ORIGIN E-4.0 ELECTRICAL DETAILS & SCHEDULES ` ► . ► E • . .. ,,v , .. , 18. CONTRACTOR SHALL SUBMIT (4) COPIES OF SPRINKLER SHOP DRAWINGS FOR APPROVAL TO LANDLORD'S FIRE ENGINEER PRIOR FOS FACE OF STUD RAR RETURN AIR REGISTER M-1.0 HVAC PLANS other Hoop 50 iW�A/ 5 TO CONSTRUCTION IF APPLICABLE. • FS FLOOR SINK RI ROUGH-IN M-2.0 DETAILS, LEGENDS AND SCHEDULES 19. GENERAL CONTRACTOR SHALL CHECK-IN WITH LANDLORD'S ON SITE TENANT COORDINATOR PRIOR TO COMMENCING M-3.0 DETAIL CONSTRUCTION. GC GENERAL CONTRACTOR STRUCT. STRUCTURE, STRUCTURAL A-2 DETAIL DETAILS M-3.1 HOOD DETAIL PLAN 20. IN ADDITION TO THE GENERAL NOTES LISTED HEREIN, A.I.A. DOCUMENT A201 GENERAL CONDITIONS OF THE CONTRACT FOR HW HOT WATER WCO WASTE CLEAN OUT -1-. 1 . 0 M-3.2 HOOD DETAIL PLAN CITY OF TIGARD CONSTRUCTION SHALL APPLY. P-1.0 PLUMBING WASTE, VENT, WATER AND GAS PLAN �r ,./ Approved .. .4/26:-..` .. .C4..ZJ... 21. TENANT'S GENERAL CONTRACTOR SHALL ARRANGE AN ON-SITE MEETING WITH LOCAL MALL MANAGEMENT PRIOR TO STARTING P-2.O PLUMBING LEGENDS AND SCHEDULES Conditionally Approved ANY PORTION OF THE WORK, SUBSEQUENT TO LANDLORD'S CONSTRUCTION RELEASE. P-3.0 PLUMBING DETAILS AND SPECIFICATIONS For only the work as described in: TITLE SHEET PERMIT N4 'D ‘ P-4.0 PLUMBING DETAILS AND RISER DIAGRAMS See Letter to:Follow . ( )r { Job ••• ss: / , ( ' l ee9 By: `l`' 4-Date: -,-/` t -O4-, orEic---z, C _ _ __ _ _ _ _ _ _ S P EC I F i CATI O S N _ _ presumptive that all said items have arrived undamaged, and in TEMPORARY BARRICADE: DIVISION 8 DOORS AND WINDOWS the proper quantities, and it shall then be the Contractor's SECTION 08210 FLUSH WOOD DOORS TILE PRODUCTS CERAMIC TILE, TiLE INSTALLATION SYSTEMS &ACCESSORIES Install temporary barricade as required by mall officials in Unglazed Quarry Tile: Provide square edged flat tile LATICRETE INTERNATIONAL GUIDE SPECIFICATION '_.' «.•:. . ' ' responsibility (AT HIS OWN COST) to promptly reorder, replace PROVIDE AND INSTALL standard solid core flush wood door. ARTICLE 1 GENERAL PROVISIONS and/or repair any such items needed for the proper completion of manner stipulated by same. SOLID CORE DOORS FOR PLASTIC LAM. FINISH: complying with the requirements specified in the tile schedule GC1.1 GENERAL CONDITIONS this project, on the agreed to date of completion. LIGHT AND POWER: FACE: Birch Sheet A1.2 1. WATERPROOFING, ANTI-FRACTURE, CRACK SUPPRESSION MEMBRANES FOR = TILE INSTALLATIONS The Standard Form of General Conditions, 1987 Edition of the Wearing Surface: Abrasive aggregate embedded in surface MEASUREMENTS: Provided by Electrical Contractor or-reuse existing from GRADE: Paint Grade A. Waterproofing, anti-fracture and crack su suppression membrane shall be thin, cold a lied, American Institute of Architects, Document No. A-201, pages one where indicated; non abrasive elsewhere. PP PP twenty-four, are hereby made a part of these The Contractor shall be responsible for an accurate taking of job location of Landlord's service and pay all cost for same, for all CONSTRUCTION: Solid Core and load bearing. Manufacturers standard factory prepackaged system consisting of EXP- through Y p P 9 J Glazed Wall Tile: Provide flat tile complying with the proprietary latex and specifications and shall » p p ry non-woven polyester reinforcing fabric. Materials shat! be non-toxic, d apply the same as if repeated here in site measurements, verifying same, and promptly furnishing exact Contractor(s) to subject space. PREFIT doors at factory with clearances of 1 8 at each vertical p PP Y p Y 9 P P Y 9 O J P rY / following requirements and the tile schedule, sheet Al A1.2 non-flammable and non-hazardous (V.O.C. compliant) during manufacture, storage, -full. Copies of same shall be on file at the office of (REITER DESIGN job site measurements to all parties requiring same. Contractor edge and at top, 1/2" at bottom, and 1/8" in 2" bevel at lock application and after cured. - - - GROUP ARCHITECTS, INC., 7965 CIRRUS DRIVE BEAVERTON, OR. 97008) must notify Tenant/Architect of any discrepancies immediately. WATER SUPPLY: edge, 3/8" clearance above floor without threshold, 3/4" above Trim Units: Provide tile trim units to match PP All interested parties shall be governed by those The Contractor shall check sales casework shop drawings as to floor with threshold. characteristics of adjoining flat tile. Waterproofing, crack suppression and anti-fracture membranes shall meet the following P g The Contractor shall make all necessary arrangements for standards compliance and physical requirements: [� General Conditions in all matters pertaining to this project, correct angles and fit to the existing space as shown. The permanent water service, water meter, and pressure regulator for all , SETTING MATERIALS ANSI A118.10 ""'�'! (i) during the period of construction, and participation in the Contractor shall permanently layout the casework on the floor purposes of construction, paying all costs in connection with same, and INSTALL doors to com I with manufacturer s instructions. Fit Standards Compliance e P Y Latex-Portland Cement Mortar: ANSI Al 18.4, composition Nil 0 project will be considered presumptive evidence of the prior to the construction of wall, ceiling, light fixtures, etc. for all water used. This shall include all means of conveying doors to frames with uniform clearance and bevels. Machine doors as follows: Water Permeability (at 30 ft.hydro/0.9 atmos/91.2 kPa) O Y g Hydrostatic Pressure (FHA 4900.1; 615-5;C Pass (40 Hours) �'" participant's full understanding of, and agreement with, the for hardware, if required. Refinish or replace doors damaged Y ( ) same to place where required. Pre acka ed dr mortar mix com osed of ortland Hydrostatic Resistance ASTM D751 - Modified 120 lbs/in (827.4 kPa) O Q conditions of the referenced General Conditions. Written dimensions shall take precedence over scaled dimensions. during installation. P 9 Y P P ( ) z cement, graded aggregate, and the following dry Elongation at Break (ASTM D-751) 20 to 30% Larger scale drawings shall take precedence over smaller scale ELECTRICAL ENERGY: Service Temperatures -20' F to +280' F G CJ LiL1016-92 SECTION 08710 FINISH HARDWARE polymer additive in the form of a re-emulsifiable P ( ) (-28' C to +13T C) 'A �C The General Conditions, Special Provisions, General Requirements, drawing. The Contractor shall make all necessary applications, pay all powder to which only water is added at job site with 4 and Technical Specifications, along with the other condition:; dues and charges, obtain necessary permits, provide and maintain Tensile Breaking Strength 2400 psi (16.55 MPa) � which follow, and as provided, as well as all applicable SUBSTITUTION: PROVIDE finish hardware throughout the Work as needed for Dry Polymer Additive: Manufacturer's standard. T S energy p p g Thickness 20 mils 0.5 mm C H I T . provisions of the Specifications, form part of the Contract and electrical ener from developers permanent electrical facilities ) P P P Bidders may offer substitutions for any item specification by for lighting, power for all electric tools and equipment required complete installation as specified on the Drawings. GROUTING MATERIALS Bond Strength to Concrete 250 psi (1.72 MPa) shall govern each Contractor engaged in work on the project submitting in writing as outlying in space provided on proposal in construction of all branches of the Work and pay for all Latex-Portland Cement Grout: ANSI Al 18.6, color as Crack Suppression (ZBD 02-1988) "Extra(>0.4 mm) whether the work be let under separate contracts or under a form. current used. NOTE: All hardware shall be installed to allow for vinyl wall covering indicated in tile schedule, sheet A1.2. TCA Service Rating (ASTM C627, Robinson Floor Test) Extra Heavy single contract. and wood trim where such occur. IT SHALL BE UNDERSTOOD by all herein concerned that any TELEPHONE: 1, composition as follows: Resistance to Chemicals (90 Day Immersion): PANDA EXPRESS INC. Prepackaged dry grout mix composed of portland cement, Brine, Sugar, Milk, Urine, 10% Acid, 10%Alkali Not Affected GC1.2 BASIC The Contractor shall DEFINITIONS proposal substitution shall have the written approval of Architect Toluol furnish FASTENERS: Softens urnish and maintain on the job site, a graded aggregate, and the following dry polymer additive Not Recommended 1683 Walnut Grove Ave. and/or Owner's Representative, before being used by Contractor, temporary telephone at the beginning of project for the use of PROVIDE all hardware with all necessary screws, and other in the form of a re-emulsifiable powder to which only water Rubber Solvents, Aromic Solvents or Ketones Rosemead, California 1.2.1 The Contract Documents otherwise it will be assumed that the Contractor's total bid is Calcium Chloride Excellent those connected with the Work and furnish free telephone services fasteners of suitable size and type to anchor the hardware in is added at job site. 91770 The Contract Documents consist of the Agreement between Tenant based upon the material or item of equipment specified. position for ion life under hard use. Furnish items complete lAPMO - Suitability for Use as Shower Pan Liner Approved/File #: 3524 on all local calls. if store telephone already exists, provide p long p to Latex Type: Manufacturers standard. Telephone: 626.799.9898 and Contractor, Conditions of the Contract and all documents additional phone. Beepers do not qualify as telephone. with expansion shields, toggle bolts, and other anchors, in Application: Use dry-set grout combined with latex listed below. EXAMINATION OF SITE AND DOCUMENT: accordance with the material to which the hardware is to be additive for grouting joints in glazed wall tile. 1. Products: Subject to compliance with requirements, provide the following: Facsimile. 626.372.8288 Before submitting a proposal, each bidder shall examine all FIRE PROTECTION: applied and the recommendations of the hardware manufacture. a. LATICRETE 9235 Waterproof, Anti-Fracture, and Crack Suppression Membrane 1.2.2 The Contract Documents shall include: Fastener finish shall harmonize with the hardware material. EXAMINATION b. or equal as determined by project architect documents, visit the site, verifying with LL any special charges or Tenant's Contractor shall provide fire extinguishers within the Drawings as listed in the Table of Contents of this set. requirements, comparing each to the other and informing themselves premises as required by code and/or insurance companies, or Examine substrates and areas were file will be installed, Specification Division 1-16 inclusive. of all conditions under which work is to be performed. All Proposals verify that one is existing in the case of a remodeling. COORDINATE with other trades to assure proper and adequate with Installer present, for compliance with requirements for Y 9 9• P P q SECTION 09510 ACOUSTICAL CEILINGS All modifications issued after execution of the Contract. shall include the costs for L.L. services and chargebacks to Tenant provision in the Work of those trades for interface with the Work installation tolerances and other conditions affecting 9 Disconnect and seal utilities serving structure to be demolished, p Landlord provided Tenant construction hand book. and for using L.L. required contractors. Such items shall include, but prior to start of demolition work. ' of this Section. performance of installed tile. All ideas, designs, arrangement and plans indicated Verif PROVIDE all labor, materials, equipment, etc., required to supply or represented by this drawing are the property of Equipment installation hand book. is not limited to, demising studs, neutral piers, roof patching, or y that substrates for setting tile are firm, dry, clean, and install all Armstrong lay-in tile and Chicago metallic Panda Express Inc. and were created for use on and free from oil or waxy films and curing compounds. this specific project. None of these ideas, designs, sprinkler contractors, etc... Include all relevant matters which may STRICTLY PROHIBITED WORK AND PRACTICES: INSTALL hardware items in accordance with the schedule included Y 9 P suspension system, including wire hangers, main tee runners, arrangements or plans may be used by or disclosed Y ceilings Verify that installation of grounds, anchors, recessed cross tees, angle molding and hold-down clips, where required. y firm, or corporation without the Institute, except as specifically required to comply with local Y 9 g p q to an person, GC1.3 DEFINITIONS affect the work or the bidding. Each bidder shall base his proposal Installation of any combustible materials above finished ceitin s p p Y q p Y frames electrical and mechanical •r written permission of Panda Express Inc. on material, methods and/or equipment complying with the specifications or in any other concealed, non-sprinklered space. on the drawings and as recommended by the Door and Hardware = a units of work, and p similar items located in or behind tile has been com MATERIALS: Phrases used in the specifications are defined as follows: and drawings. codes. Install hardware in compliance with the manufacturer leted s P as shown" - As shown on the accompanying drawings. Imposing any structural load, temporary or permanent, on any part instructions and recommendations. Set units level, plumb and before installing tile. ACOUSTICAL CEILING: SEE CEILING TILE SCHEDULE, SHEET A-1.1 true. "provide" - Provide and install complete, with all necessary The words "The Contractor Shall" are intentionally omitted from of the Landlord's work or structure without approval. Do not roceed with installation until unsatisfactor accessories and incidental materials and supplies. the specifications. Where directions or instructions are stated, P y SUSPENSION SYSTEM: conditions have been corrected. REVISIONS: "provided by Tenant" - Materials or goods will be delivered without specific reference as to who is responsible, the inference ADJUST and check operation 48"P P Cutting any hole in Landlord-installed floor slabs, walls or p ation of every unit. Replace units which 01. Main tee runners shall be installed at 48 o.c. having cross F.O.B. jobsite by the Tenant at no expense to the General is intended to be the Contractor for the Work in the specification roof without proper approvals and not in accordance with cannot be adjusted to operate freely and smoothly. ANSI Tile Installation Standard: Comply with ports of =_ tees at 24 o.c. including #425 accessible hold-down clips and Contractor. Unloading, storage, installation, and/or assembly of section in which the directions or instructions are intended. DIVISION 9 FINISHES perimeter wall molding at all vertical abutting surfaces. » instructions herein and proper construction procedures. ANSI 108 series of tile installation standards included p g g items provided by Tenant shall be by General Contractor unless under "American National Standard Specifications for the A otherwise noted. CODES AND STANDARD: Attaching any work to metal deck or hanging from plumbing and SECTION 09250 GYPSUM DRYWALL Installation of Ceramic Tile" that apply to type of setting INSTALLATION: "install" - Install items, complete, providing ali incidental and All Work, materials and installation shall be in strict sprinkler piping or conduit. PROVIDE all Work in accordance with manufacturer's directions as necessary supplies and materials. P P P g and grouting materials and methods indicated. COMPLY WITH MANUFACTURERS instructions and recommendations and accordance with all ordinances, state and local building codes, required herein, and as shown on the drawings for complete » protection. /4\ General Contractor - The General Contractor or any oor all of latest edition, of the authorities having jurisdiction. g drywall partitions, TCA Installation Guidelines: TCA "Handbook for Ceramic Y POLLUTION CONTROLS: erection and finishings for wall artitions, soffits, etc., his various subcontractors. g J Tile Installation ; comply with TCA installation methods (STORAGE AREA ONLY) A "Tenant"is various s subcontractors. All General Conditions references to "Owner shall Use water sprinkling, temporary enclosures, and other suitable including metal studs and all accessories as may be required. indicated. MATERIALS: refer to PANDA EXPRESS, INC. Design Loads: Loads and code restrictions for all design methods to limit dust and dirt rising and scattered in air to A\ ' considerations shall confirm to the Local and State codes, and lowest practical level. Comply with governing regulations MATERIALS: Extend tile work into recesses and under or behind Vinyl Composition Tile - See FINISH SCHEDULE Landlord - Owner of the Shopping Center property, developer Vinyl Cove Base - See FINISH SCHEDULE of the Shopping Center property or any of their agents authorized all governing codes. pertaining to environmental projection. Do not use water when it PRODUCTS herein specified are identified by reference to United equipment and fixtures to form a complete covering to act in their place. PERMITS: may create hazardous or objectionable conditions such as ice, States Gypsum Company. However, similar products of the National without interruptions except as otherwise shown. INSTALLATION: flooding and pollution. Gypsum, Penn Metal or Inland Steel Companies will be acceptable. Terminate work neatly at obstructions, edges, and corners COMPLY with manufacturer s instructions and recommendations for The Contractor shall be responsible for the proper Clean adjacent structures and improvements of dust, dirt and without disrupting pattern or joint alignments. preparation of substrate, installation requirements, and cleaning. ARTICLE 2 INSURANCE application for and securing of all necessary permits, as well adjacent ' 1.GYPUSM WALLBOARD (GYP. BD.): P 9P � 9 P P q g• pP 9 rY P debris caused by demolition operations, as directed by Architect Accurate! form intersections and returns. Perform cutting as the observance of all applicable City, County, and Accurately 9 ISSUE DATE: PP y= Y or governing authorities. Return adjacent areas to condition Tapered edge 48" wide in len9ths as required. Firecode 5/8" and drilling of tile without marring visible surfaces. 2.1 The General Contractor and all subcontractors are required Federal Laws, Regulations, or Ordinances, Mall requirements and existing prior to start of work. �� 9 9 SECTION 09650 RESILIENT FLOORING 9 P one hour fire rating and 1/2' where indicated, or as Carefully grind cut edges of tile abutting trim, finish, or 1ST PERMIT APPLICATION 01/09/09 to obtain the following Insurances, and at their request furnish shall include in their proposal cost of same. required. built-in items for straight aligned joints. Fit tile closet to - evidence to the Owner or the Landlord. All insurance shall name DIVISION 3 CONCRETE _ Y MATERIALS: PANDA RESTAURANT GROUP, INC., and Reiter Design Group Architects, inc. APPLICATION OF MATERIALS AND/OR EQUIPMENT: electrical outlets, piping, fixtures, and other penetrations so 2ND 9 p Provide concrete as specified in drawings. 2.WATER RESISTANT GYPSUM WALL BOARD. p P g' Vinyl Composition Tile - See FINISH SCHEDULE as additional insured parties. Attention is hereby directed to the following requirement for p g =_ that plates, collars, or covers overlap tile. Y P 3RD each prime and subcontractor: DIVISION 5 METALS 1/2 water resistant board for tile work within 48" wet areas. Vinyl Cove Base - See FINISH SCHEDULE 4TH P SECTION 05000 LIGHT GAUGE METAL FRAMING 3. METAL STUDS: pattern. Align joints Unless otherwise shown, lay tile in grid 2.1.1 Workman's Compensation Insurance in accordance with the Y g INSTALLATION: laws of the State in which the property is located and the That the application of a material and/or equipment item to pattern. Align joints when adjoining tiles on floor, base, 5TH Landlord's requirements. Owner shall keep a copy in file all time unsatisfactory work installed by others, constitutes acceptance MATERIALS: Channel - type roll form 25 gauge min. (Unless otherwise walls, and trim are same size. Lay out tile work and center COMPLY with manufacturer's instructions and recommendations for 6TH of that Work and assumption of full responsibility for prior to FURNISH galvanized structural steel C studs sizes, minimum 18 indicated) electrogalvanized steel in width as shown. tile fields in both directions in each space or on each wall preparation of substrate, installation requirements, and 2.1.2 Comprehensive General Liability Insurance including starting the specific application, notify in writing the gage or as indicated on drawings and as required with all Include metal runners. area. Adjust to minimize tile cutting. Provide uniform cleaning. Contractural Liability with limits set forth by the lease and the Architect and/or Owner's Representative of any defect or necessary accessories. 4. CARRYING CHANNELS AND HANGING WIRE: joint widths unless otherwise shown. Landlord's requirements. deficiency which would impair complete and satisfactory INSTALLATION: 1 1/2" deep, 475 lbs per 1,000 feet. Grout the to comply with the requirements of the following applications or installation of his Work or guarantee. installation standards: SECTION 09800 PENETRATING SEALER (TILE GROUT) 21.3 Automobile Liability Insurance including Contractural INSTALL metal framing systems in accordance with manufacturer's Minimum 8 gauge hanging wire at 48" o.c. each way. DRAWN BY SAR Y g For ceramic tile grouts (sand-portland cement, d set, PROVIDE stain resistant, invisible, below surface nonflammable grout sealer Liability as set forth by the lease and the Landlord's MANUFACTURERS INSTRUCTIONS: printed or written instructions and recommendations, unless 9 P rY- Y Y 5. FURRING CHANNELS: commercial portland cement, and latex-portland cement at all tile locations. requirements. Where installations include manufactured products, comply with otherwise indicated. Install continuous tracks-sized to match P = P Secure tracks as recommended by stud manufacturer for 7 8" hat shaped. grouts), comply with ANSI Al 8.10. manufacturer's applicable instructions and recommendations for studs' y / P MATERIALS: type of construction involved. 2.1.4 Builder's Risk Insurance in the amount of the estimated installation, to the extent these are more explicit or more yp 6. JOINT TREATMENT: FLOOR INSTALLATION METHODS PRODUCTS herein specified are identified by reference to Aqua Mix cost of Tenant's improvements. stringent than requirements indicated in the Contract Documents. Latex-Portland Cement Mortar: ANSI A108.5. Set studs plumb, except as needed for diagonal bracing or Perf-A-Tape and cement. Incorporated, Penetrating Sealer. PANDA PROJECT#: S4-n9-D2116 required for non-plumb walls or warped surfaces and similar Quarry Tile: Install tile to comply with requirements 2.2 indemnification Provide attachment and connection devises and methods for 7. CORNER BEAD: indicated below for setting-bed method, TCA installation EXPECTED WEAR ARCH PROJECT#: 0$21 securing work properly as it is installed; true to line and requirements. The Contractor agrees to indemnify and save harmless the Shopping g P P Y Standard or multiplex types. method related to type of subfloor construction, and grout * 3 to 5 years on exterior applications. Center Tenant, its agents, servants, and employees, and the level, and within recognized industry tolerances if not otherwise type:Latex-Portland Cement Mortar: ANSI A108.5., indicated. Allow for ex expansions and building movements. install supplementary framing, blocking and bracing in metal 8. CASING BEAD: Concrete Subfloor, Interior: TCA F113. * At least 5 years on interior applications. Tenant's Architect and Engineer from and against any and all P g framing system whenever walls or partitions are indicated to _ liability or damage to property occasioned by any act or omission * Adversely affected by abrasion and repeated exposure to acids. of the Contractor, his subcontractors, servants, or employees, VISUAL EFFECT: support fixtures, equipment, services, casework, heavy trim and WALL TILE INSTALLATION METHODS Install types * Wipe all excess sealer from surface after 2 to 3 minutes. including any and all expense, legal or otherwise, which may be Provide uniform joint widths in exposed work, organized for best furnishings, and similar work. No. 200 and 300 only in sizes as appropriate for edges and of file designated for wall application to comply with ARCHITECT: " incurred by the Tenant, its agents servants, or employees in the possible visual effect. Refer questionable visual-effect choices recesses of board where exposed. requirements for setting-bed methods, TCA installation COVERAGE: to Architect Owner's representative esti for final decision. Recheck Secure studs to top and bottom runner tracks by either welding or methods related to subsurface wall conditions, and defense of any claim, settlement or suit. / screw fastening at both inside and outside flanges. 9. RERF-A-BEAD AND EDGE TRIM: grout types measurements and dimensions of the work, as an integral step of g g g YP Gallon (3.78 L) will seal from 300 to 1,000 sq. ft. RPG Perf-A-Trim. WATERPROOFING INSTALLATION (28 to 93 sq. m.) per coat. starting each installation. Install horizontal stiffeners in studs stem as required, spaces ARTICLE 3 EXTRA WORK system q P 10. FASTENERS: * Varies depending on porosity and texture of surface, MOUNTING HEIGHTS: (vertical distance) at not more than 4'-6" o.c. Install waterproofing to comply with waterproofing manufacturer's written temperature, humidity, and method of application. REITER DESIGN GROUP 3.1 Any and all work which is performed by the Contractor, or by Where mounting heights are not indicated, mount individual units DIVISION 6 CARPENTRY Type S bugle head self-drilling, self-tapping in lengths instructions to produce a waterproof membrane of uniform thickness bonded securely * One thin coat sufficient to seal most dense surfaces. as required. Use with power screw driver. to substrate. * Additional thin coats may be necessary for more porous ARCHITECTS INC. any Subcontractor, without having specific approval from the of work at industry-recognized standard mounting heights for GENERAL NOTES: , General: Provide products that comply with ANSI A118.10 and the surfaces. 7965 SW CIRRUS DRIVE Tenant in writing, shall be performed by said Contractor at his applications indicated. Refer questionable mounting height PROVIDE AND OR INSTALL all rough carpentry, finish carpentry INSTALLATION: P PY own risk without any obligation or responsibility of the Tenant choices to Architect/Owner's representative for final decision. / g p ry' P O` » descriptions in this article. METHOD OF APPLICATION: BEAVERTON,OREGON 97008 including millwork, finish hardware, rough hardware, fastening COMPLY with Gypsum Construction Handbood by United States or the Architect. All work which is above and beyond the scope (503)574-3036 FAX(503)574-2916 of the Drawings and Specifications, or any part of the PROTECTION AND CLEAN UP: devices, and miscellaneous accessories as may be required herein Gypsum Co, and "Recommended Specifications for the Application * Surface must be sound, thoroughly clean, and free of any and/or shown on the drawings. and finishing of Gypsum Board" by the Gypsum Association for all CLEANING AND PROTECTION foreign matter including previously applied sealers or grout. Construction Documents, must be specifically authorized by the The Contractor shall be responsible for the proper protection of installation work. Tenant in writing. All requests for additional payments must be adjacent items and surfaces from damage resulting from the SECTION 06000 ROUGH CARPENTRY Cleaning: Upon completion of placement and grouting, * Apply using dense sponge-mop, sprayer or brush. approved by the Tenant prior to the start of that work. furnishing or installation of his Work and shall promptly FURNISH AND INSTALL all framing as may be required for interior SECTION 09300 TILE clean all ceramic tile surfaces so they are free of foreign * Thin even coats recommended for best results. replace, at his own cost, such damaged Work. He shall also be * Wipe all excess sealer from surface after 2 to 3 minutes. STAMP. The following General Requirements supplement and/or supersede responsible for the proper protection of his and others Work from Partition, baffle, walls, soffits, ceilings, storefront as noted STANDARDS: matter. ARe & where shown using members as required. MORTAR and grout materials and installation standards of the Finished Tile Work: Leave finished installation clean and INSTALLATION: the foregoing General and Supplementary Conditions for Contract damage by any including freezing or overheating. Use plastic American National Standards institute (ANSI) and Standard Specification free of cracked, chipped, broken, unbonded, and otherwise Work and are hereby considered a part of the Contract Documents. covering over furniture, display cases, equipment and finishes. DIMENSION LUMBER AND BOARDS: for Ceramic Tile ANSI A137.1 apply to the work, except as otherwise defective tile work. * ALWAYS TEST A SMALL AREA first to determine ease of .,.'''GEORGE T. RO8ISON C The Contractor shall remove all debris from the premises on a No.1 Pine or No.1 Fir, sound, thoroughly seasoned, free from indicated. Provide grout sealer at all locations. application and desired results; test for stain repellency using . DIVISION 1 GENERAL REQUIREMENTS daily basis; all dust and construction debris are to be removed. likely contaminants. warp. Construction as required for framing, blocking, furring, Any broken, damaged, marred, unclean, or otherwise imperfect work etc. This Section includes the following: * Gloves an eye protection should be worn during application; • • SECTION 01000 SUMMARY OF WORK: shat! be corrected by the Contractor before his Work shall be if spraying wear respirator rated for dusts and mists. PO''i LAND, OREGON •� considered complete. Use dust barriers. PLYWOOD PANELS: 1. Unglazed quarry floor tile reference tile schedule, sheet A1.2 * Avoid overlapping, over spraying, puddling and rundown. 2520 �Q NOTE: All of the work under each heading of these specifications g ( for specified tile and grout, sizes, color, texture, and manf. * Immediately wipe off all surrounding materials, particularly any shall be governed by the General Conditions, Special Provisions, FOR USE as indicated on drawings. (Wall mount self, electrical, 1��j 9 Y P Upon completion of the Work interior and exterior of all glass 2. Glazed wall tile, tileschedule, sheet A1.2 for specified OLD tel and security panel backup, etc.) � p metals, glass and other very dense or shiny surfaces. OF the Drawings and the Specifications, as well as the following and glazing, floors, walls and ceiling surfaces, electrical tile and grout, sizes, color, texture, and manf. * AQUA MIX SEALER'S CHOICE is recommended in place of 0/Zcvi �: General Requirements: fixtures, mechanical equipment, etc.; it is necessary to remove FASTENING DEVICES: 3. Water proof membrane - (second floor applications only) PENETRATING SEALER in food preparation of serving areas or tr) all dirt, stains, and marks. The Folding Closure, sign, glass and Installer Qualifications: Engage an experienced Installer when maximum stain protection is required. FURNISH all anchors, bolts, screws, etc., as may be required; SCOPE: wood shall be cleaned and polished. The store shall be made non-corrosive and non-stainin g exposed osed to exterior. who has successfully completed tile installations similar P CURE TIME: The Work under each heading of these specifications shall include clean and fit for immediate occupancy by an independent cleaning in material, design, and extent to that indicated for Project. all labor, material, equipment and services necessary for and agent, with the approval of Owner, at the Contractor's expense. PRESERVATIVES: ANSI Standard for Ceramic Tile: Comply with ANSI * Ready for surface traffic within 2 hours. o 0. said heading as indicated on the drawings, set forth in the A137.1 "American National Standard Specifications for * PANDA EXPRESS o PRESSURE TREAT all wood to be permanently fastened into place Allow at least 2 hour drying time between coats if more than c� specifications, or otherwise required. General Contractor is to supervise and schedule proper Ceramic Tile for es, and grades of file 1 coat is needed. with "Non-Corn" chemical process as manufactured by Koppers types, 9 a installation of all parts of Work pertaining to a finished by him Company, Inc., Forest Products Division, complying with indicated. Furnish tile complying with "Standard Grade" Sealed area should be kept I F * pt dry for at least 12 hours. TIGARD TOWN SQUARE Work done hereunder includes furnishing all labor, material or by the Tenant. Underwriters Laboratories, Inc., fire hazard classification of requirements unless otherwise indicated. Will achieve full cure in 24 hours. services, and equipment necessary and/or incidental to perform flame spread 15 or less, all such wood to be properly labeled ANSI Standard for Tile Installation / Materials: Comply with all work through the proper completion of all Work as may be GUARANTEE: prior to delivery. HANDLING AND STORAGE d further specified and/or a shown on the plans, or otherwise The Contractor shall guarantee the Work to be free from defects P y. ANSI standard referenced with products and materials cv required. indicated for setting and grouting. * Use full strength; no not dillute. 1.-- 9 of materials or workmanship, including discoloration, rattling SECTION 06200 FINISH CARPENTRY 9 = 16230 PACIFIC HWY. SUITE 100 * Store tightly capped in original container to prevent evaporation. and leaking, for a period of one year from the date of final Colors, Textures, and Patterns: Where manufacturer's g y PP P P TIGARD, OREGON N In case of conflict between drawings and specifications the payment. Application by the Contractor for final payment shall FURNISH AND INSTALL all that is required for doors and frames, standard products are indicated for tile, grout, and other * Unused stored product is freeze/thaw stable. 0. o Contractor will be deemed to have estimated on and agreed to be considered as presumptive evidence of his full understanding finish trim and paneling. products requiring selection of colors, surface textures, ONGOING MAINTENANCE: provide, the greatest quantity and better quality of materials of and agreement with conditions of the guarantee provision, and Types of finish carpentry work include: (if required) patterns, and other appearance characteristics, provide P g q y q y g his p YP P ry ( q ) P PP p * Use AQUA MIX TILE AND GROUT CLEANER and/or AQUA MIX and Work. he shall remove and replace with new, at his own expense, all specific products or materials complying with the following i such work P P P P 9 * / Q = o k or materials found by the Owner's Representative to be Moldings requirements: TILE PLUS MORE for routine cleaning U Include general construction, electrical, plumbing, HVAC, and defective within the guarantee period. Trim * AQUA MIX HEAVY-DUTY DILE AND GROUT CLEANER is t as hereinafter may be Provide the trim and accessories that match color and Q installation of all such Work except Y finish of flat tile. recommended for heavy duty cleaning/degreasing. required. APPROVAL OF SUBCONTRACTOR: HARDWOOD: cv ITEMS FURNISHED BY THE TENANT AND INSTALLED The Contractor agrees that he is fully responsible to theTenant Paint grade hardwood for interior moldings and trim in sizes as in...2 I 0 0 BY THE GENERAL CONTRACTOR. for the acts and omissions of his subcontractors and of persons indicated on the drawing. (Note: Prefinish wood per Millwork o. directly employed by him. Nothing contained in the Contract Schedule provide by Owner installed by G.C.) o It shall be the Contractor's sole responsibility to receive, i check and confirm the arrival in good order, of all items called Documents shall create any contractual relation between any for to be furnished by the Tenant and installed by the subcontractor and the Owner. DIVISION 7 MOISTURE PROTECTION co Contractor. The Contractor shall notify the Tenant (IN WRITING) SECTION 01200 TEMPORARY FACILITIES SPECIFICATIONS o of any such items missing or damaged within 3 days of receiving Provide and complete all preliminary work and temporary date. Failure to so notify the Tenant will be considered proof construction required as indicated and required. . SECTION 09900 PAINTING SECTION 09986 SANITARY WALL&CEILING PANELS TURNOVER REQUIREMENTS •- •• ••• GENERAL FINISH NOTES .. • The Contractor shall arrange for all inspections and furnish Owners - WORK INCLUDES surfaces preparation and painting or finishing of representative with the certificate of occupancy. G.C. is also to 1. ALL TiLE DIMENSIONS ARE DESIGNED TO LAY OUT IN AN EQUAL MANNER. IF _.. all interior surfaces exposed to view, throughout the Project. Submit manufacturers product data including installation literature. TiLE MUST BE CUT,THE GROUT LINES SHALL ALIGN WiTH ADJACENT TILES OR P g Submit maintenance data as art of project closeout. Maintain 65 provide a type written list of names, addresses and phone numbers of BE CENTERED AND CUT IN OBVIOUS LOCATION. G.C. SHALL COORDINATE THE E Where items or surfaces are not specifically mentioned, paint P p 1 all sub-contractors and material suppliers. INSTALLATION OF BYP. BD.WITH TILE DIMENSIONS TO PERMIT EVEN INSTALLATION. ,# the same as similar adjacent materials or areas. The Work of degrees in spaces for 48 hours before, during and 48 hours after _ this Section includes, but is not necessarily limited to painting application. Variation in face alignment of adjacent panels shall The Contractor shall be responsible for having the entire store 2. ALL SURFACES TO RECEIVE PAINT FINISH SHALL BE PREPARED TO SHOW NO / y --, _- 40K\ or finishing of the following items. not exceed 1/32". P g DEFECTS. _ - _ 9 9 clean and spotless at the time of furniture installation and at A. APPLY ONE(1)COAT PRIMER-SEALER All interior drywall surfaces not finished otherwise. turn over B. APPLY TWO(2)COATS FINISH. NO STIPPLE FINISH ON ALL PAINTED _ (painted). PRODUCTS SURFACES. SEE SCHEDULE ON PLANS FOR COLOR AND TYPE. Prior to the store opening, Contractor is to arrange for an 3. ALL INTERIOR GYP. BD.TO RECEIVE PAINT FINISH SHALL BE TAPED,SEALED, CI 6 0 N °I) Acrylic wall panels shall be Lasco Board FRP Panels. Panels shall be Independent Balancing Contractor to balance the HVAC system and AND SANDED TO RECEIVE FINISH. GYP. BD. UNDER FRP OR S.S.SHALL ONLY • MATERIALS: PVC; .090" thick by 4'-0" wide; #924; Pearl Gray-Luster, Class A, or provide a copy of the balancing report to the Landlord and Owner's BE FIRE TAPED AND SANDED. ALL INTERIOR GYP. BD.TO BE TRUE AND LEVEL. O equal USDA accepted, semi rigid fiberglass reinforced plastic paneling, representative. 4. GYP. BD.SHALL EXTEND AT MINIMUM OF 6"ABOVE LAY-IN CEILING SYSTEMS 0 Q PROVIDE products equal to materials listed in the Finish Class A: UL classified flame-spread less than 20, fuel contributed 0, OR UP TO TYP. BD. CEILING. GYP.BD.ON DEMISING WALLS SHALL EXTEND Q P TO THE STRUCTURE ABOVE UNLESS OTHERWISE NOTED. Schedule. Note that proprietary names used to designate colors and smoke-developed less than 200, per ASTM E-84. Contact Lasco If required by Landlord the Contractor shall secure any necessary c �O (on the Drawings) or materials (scheduled herein) are not in Anaheim, California at 800-626-1220. Fabricate panels within approvals for the store sprinkler system for the Landlord's 5. ALL GRILLES SHALL BE PAINTED TO MATCH THE CEILING OR ADJACENT WALL �! intended to imply that products of named manufacturer are FINISH. P Y P specified tolerances in accord with approved shop drawings to sizes insurance carrier. �. SSG required to exclusion of equivalent products of other and shapes indicated. 6. ALL FLOORS SHALL BE SMOOTH AND LEVEL WITHOUT DEPRESSED OR RAISED C H 1 N� manufacturers. Prior approval of Owners Representative required. Contractor to turn over all keys to the Owner's representative and AREAS,EXCEPT PROVISION SHALL BE MADE TO HAVE SMOOTH,EVEN SLOPE TO marking each key for identification. FLOOR DRAINS. THE SURFACE SHALL BE ACCEPTABLE TO RECEIVE FINISH. EXECUTION 9 Y SURFACE PREPARATION: The Contractor shall set all time clocks, thermostats, etc. per 7. VERIFY AND COORDINATE THE LOCATION OF ALL WALL OR CEILING ACCESS Install two panels full height as mockup for Owner's acceptance. Owners representatives requirements. PANELS WiTH THE ARCHITECT. PANDA EXPRESS INC. CLEAN surfaces of dirt, rust scale, rease, moisture, or other Install wall panels in accord with approved shop and erection drawings. 8. PROVIDE METAL CORNER BEAD,TRiM AND CASING FOR ALL EDGES AND g The Contractor shall explain the operation of all mechanical CORNERS OF GYP.BD.SURFACES ON PAINTED WALLS. CLEAN GYP.BD. 1683 Walnut Grove Ave. conditions otherwise detrimental to formation of a durable t Install sall panels using manufacturers recommended adhesive (or P systems to the Owner's representative and providing copies of CORNERS WITHOUT METAL CORNER BEADS SHALL BE UNDER FRP,TILE,OR S.S. Rosemead, California film. Perform preparation and cleaning procedures in accordance manufacturers non-fume adhesive where solvent vapors cannot P p g p operation, maintenance and warranty manuals. 91770 with paint manufacturer's printed instructions for each be ventilated) to back of panels for 100% 9. PROVIDE STIFFENERS, BRACING, BACK-UP PLATES, ETC.AS REQUIRED AT STUD particular substrate condition. coverage, with a notched trowel. Install panels with surface texture WALLS FOR SUPPORT OF FIXTURES AND OTHER EQUIPMENT. Telephone: 626.799.9898 grain aligned. Provide edge molding at exposed joints between panels 10. ALL EXISTING SURFACES SHALL BE INSPECTED AND ALL NECESSARY Facsimile: 626.372.8288 WOOD: and at top and bottom edges. Seal bottom edge of panels, whether FIRE PREVENTION NOTES PREPARATORY WORK SHALL BE DONE IN ORDER TO RECEIVE NEW FINISHES. exposed or concealed. 11. BEFORE PAINTING OR FINISHING WORK iS TO BEGIN,ARRANGEMENTS SHALL BE CLEAN surfaces of dirt, oil and other foreign substances with All work shall comply with the version of the Uniform Fire Code (U.F.C.) MADE FOR PROPER VENTILATION AND LIGHTING IN ALL AREAS. mineral spirits, and sandpaper and dust off prior to finishing. SECTION 10522 FIRE EXTINGUISHER as amended and adopted by the local agencies having authority. 12. ALL FLOOR MATERIAL CHANGES SHALL OCCUR AT DOOR CENTERLINE UNLESS REMOVE hardware, accessories, plates, lighting fixtures, and OTHERWISE NOTED. All ideas, designs. arrangement P g g The Contractor shall provide min. one 2A1OBC fire extinguisher within g gement and plans indicated or PROVIDE minimum of one (1) Class ABC 10 lb. d chemical or as P g similar items in place and not to be finish-painted, or provide dry 75 ft. travel distance for each fi 000 s.f. or portion thereof on each 13. FLOOR MATERIALS SPECIFIED ON THE FINISH SCHEDULE SHALL EXTEND UNDER Panda Express nc.tand dwere c created for ruse�onof required by the State Fire Marshall and furnished by G.C. at the start of p surfaced-applied protection prior to surface preparation and floor. (U.F.C. Article 10, division III, U.F.C. Standards 10-1 and ALL EQUIPMENT AND COUNTER AREAS. this specific project. None of these ideas, designs, Construction. arrangements or plans may be used by or disclosed painting operations. Remove, if necessary, for completion of C.A.C. T-19, Sec. 3.29). Provide one portable fire extinguisher which 14. FLOOR CONTRACTOR SHALL SUBMIT TO OWNER THREE COPIES OF to any person,fi m, or corporation without the painting of each space or area, reinstall removed items. SECTION 11400 FOOD SERVICE EQUIPMENT INSTALLATION has a classification of not less than K-Type for kitchen (U.F.C. Sec. MANUFACTURER'S MAINTENANCE MANUALS FOR THE FLOOR MATERIAL INSTALLED. written permission of Panda Express Inc. GENERAL 10.313 . Location to be approved by the Architect prior to installation. COMPLY with manufacturer's printed directions in applying paint ) PP Y P 15. ALL TiLE SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS - materials. Use applicators and techniques best suited for CONTAINED IN THE HANDBOOK FOR CERAMIC TILE INSTALLATION OF THE TILE substrate and type of material being applied. Permits and Certificates: Provide for inspections and procure permits Penetrations of rated walls shall be protected by assemblies of COUNCIL OF AMERICA(CURRENT EDITION). and certifications of acceptance as may be required by governing appropriate rating, including doors, ducts, etc. 16. ALL INTERIOR FINISHES SHALL COMPLY WITH APPLICABLE LOCAL CODES AND SCHEDULING: authorities. REGULATIONS. REVISIONS: All required fire damper assemblies including sleeves and installation APPLY first-coat material to surfaces that have been cleaned, Arrange for delivery ry of food service equipment to project, receive at procedures shall be approved by the Building Department Inspector 17. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ADEQUATE SURFACE CONDITIONS THAT EXIST FOR THEIR WORK. iF ADEQUATE SURFACE CONDITIONS A I, pretreated or otherwise prepared for painting as soon as site. Unload, protect, set-in-place, and coordinate final connections, prior to installation. DO NOT EXIST THE SUBCONTRACTOR SHALL NOT PERFORM THEIR WORK UNTIL practicable after preparation and before subsequent surface and adjustment. THE CONDITION IS CORRECTED. deterioration. Allow sufficient time between successive coating All air-handling cutoff and smoke-detected fire damping equipment �3 required by the local agencies having authority and the Landlord shall 18. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. to permit proper drying. Do not recoat until paint has dried to Existing Conditions: Drawings are schematic in showing location and q Y 9 9 Y At where it feels firm, does not deform or feel sticky under sizes of equipment. Report in writing to Owner at time of shop be provided and installed by the Mechanical Contractor. 5 moderate thumb pressure, and application of another coat of paint drawing submittal, for Owner's evaluation and instructions, conflicts or does not cause lifting or loss of adhesion of the undercoat. minor deviations necessary to complete the work. Coordinate All work done on existing rated walls shall be repaired to maintain FIRE DEPARTMENT NOTES: electrical equipment to ensure compatibility with available building the existing rating. 8 APPLY PAINT to completely cover previously painted surfaces, to electrical supplies. EXITS provide an opaque, smooth surface of uniform finish, color, The Contractor shall provide new fire proofing as required 1. No latch or locking device except panic hardware permitted appearance and coverage. Cloudiness, spotting, holidays, lap by code throughout the space. 2. Exit doors must swin in the direction of exit travel when marks, brush marks, runs, sags, ropiness or other surface Equipment Installer: Equipment installation shall be under direct 9 supervision of qualified personnel having at least five years satisfactory serving any hazardous areas, or any other occupancy serving imperfections will not be acceptable. P q P 9 Y -, performance in food service equipment installation, testing, service Where required, flame spread ratings of material used in the an occupant load of 50 or more. and usage instruction. construction will be supplied to the Fire Department by the ISSUE DATE: Contractor ordering the materials. FIRE PROTECTION EQUIPMENT APPLY ADDITIONAL PAINT coats when undercoats, stains or other 1sT PERMIT APPLICATION 01/09/09 1. The installation of Automatic Fire Sprinkler System shall comply - conditions show through final coat of paint, until paint film is PRODUCTS Illuminated exit signs with battery packs and audible signals shall be with the U.B.C. Standards No. 9-1. 2ND of uniform finish, color and appearance. Give special attention provided as shown on the drawings and as required by code. 2. All commercial-type cooking equipment shall be protected by to insure that surfaces, including edges, corners, crevices, and Food service equipment will be furnished by Owner and shall be All exit signs to be wired to a dedicated circuit. 3RD g 9 9 an approved Automatic Fire Extinguishing System. exposed fasteners receive a dry film thickness equivalent to that installed by Contractor (OFC!). 4TH if flat surfaces. Remove, refinish or repaint Work not in Coordinate smoke evacuation system requirements with the Landlord. 3. Provide one portable fire extinguisher which has a classification compliance with specified requirements. EXECUTION Provide systems in accordance with applicable codes. of not less than K-Type for the kitchen. 5TH Confirm locations and correctness of rough-in work prior to MISCELLANEOUS 6TH equipment installation. Coordinate fire alarm system requirements with the Landlord. 1. All decorative materials shall be maintained in a flame CLEAN-UP: retardant condition. Uncrate, assemble, install, erect, connect and adjust all items of Coordinate fire sprinkler system requirements with the Landlord. DURING the progress of the Work, remove from site discarded paint equipment, ensuring proper fit and operation. Installation shall comply with the "NFPA 13". Fire sprinkler protection 2. Building occupant shall secure permits required by the fire dept. materials, rubbish, cans and rags at end of each work day. Upon shall be provided above and inside walk-in coolers and freezers. from the Fire Dept. Bureau prior to occupying this building. completion of painting Work, clean window glass and other paint- Install and make connections to services and supplies in accordance All sprinkler work to be done after hours. DRAWN BY: SAR splattered surfaces. Remove spattered paint of otherwise or with manufacturer's instructions, making final leveling and adjustments 3. Building numbers shall be easily visible and legible from the st. interior finish shall comply with applicable & local ordinances as or road fronting the property. defaced painted surfaces after completion of Work of other as connections are made. stipulated by governing agencies. trades. If Owner deems clean-up is not satisfactory, an independent cleaning service will be brought in, at the Ensure that water lines are equipped with operating shutoff valves Provide an approved automatic fire extinguishing system in the ,.... Contractor's expense to complete the clean-up. near each item of equipment and that connecting points are clean. cooking exhaust hood (U.F.C. Sec. 10.313(d)) or as stipulated PANDA PROJECT#: S4-09-D2116 by local governing agencies. ARCH PROJECT#: 0821 PAINT SCHEDULE: Provide strainer, check valves, pressure-reducing valves and other All decorative materials shall be maintained in a flame-retardant accessories needed for proper installation. condition (C.A.C. T-19, Sec. 1.14, 3.08, 3,21 and SEE PAINT SCHEDULE, SHEET A1.0 U.F.C. Sec. 11.204, Sec. 25.104). * Final finish is subject to approval by Owner, if finish is install equipment in accordance with NSF Manual on Sanitation deemed unsatisfactory, another application will be required Aspects of installation of Food Service Equipment. Ducts serving a cooking exhaust hood shall be enclosed in a at the contractors expense. ARCHITECT: P fire rated enclosure (see mechanical drawings for requirement). Where appropriate, anchor equipment rigidly into place with appropriate The enclosure shall be separated from the duct by at least R. P G anchors and provide filler plates between adjacent equipment and 3 inches and by not more than 12 inches. structural elements using concealed clips. Maintain required clearances between equipment and walls. Plans for all fixed fire protection equipment shall be submitted to the Fire Marshal approval prior to installation. REITER DESIGN GROUP Testing, cleaning and calibration: Building occupant shall secure permits required by the Fire Department ARCHITECTS, INC. from the Fire Prevention Bureau prior to occupying this building. 1. Provide on-site testing of equipment to ensure proper operation, 7965 SW CIRRUS DRIVE making such modifications, corrections, calibrations and Building numbers shall be easily visible and legible form the street BEAVERTON,OREGON 97008 adjustments as necessary for proper operation of equipment or road fronting the property (U.F.C. Sec. 10.208). When applicable. (503)574-3036 FAX(503)574-2916 for its intended use. The construction, remodel, or demolition of a building shall 2. Clean equipment upon installation and adjustment and again comply with U.F.C. Article 87. when demonstrated at close of project. Remove all protective film from locations. Provide occupant load sign complying with the codes as referenced STAMP: c, under PROJECT INFORMATION on sheet T-1. 3. Lubricate all working parts as recommended by manufacturer. A's .z.S. GEORGE T. ROBISON 'C' Demonstration: G II.` C') 1. Demonstrate operation and maintenance equipment to Owner's • • - personnel at close of project. Set up by Owner Representative. t PORT 1•ND, OREGON , 2520 O 2. Provide operating assistance when kitchen is first put into 6' ")4'operation, including one full working day of instruction in OF g operation, adjustment and servicing equipment in each kitchen < - area Set up by Owner Representative. CV DIVISION 12 FURNISHINGS - All store furnishings not in contract. 0 PANDA EXPRESS O CV ,..._ 0. TIGARD TOWN SQUARE 0) 3 16230 PACIFIC HWY. SUITE 100 o TIGARD, OREGON r CV in 0. O cn / 0 Ce Q No '(.71 T...2 . 1 ck 0 -4- i SPECIFICATIONS CV co O '.L r � � � ' � � ' SIT E DIV=LOPMINT: E NTRA\ C S: T_LEPI- ON _S: • . 42. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29- INCHES _z` 17. PROVIDE AT METALLIC SIGN OVER EACH STOREFRONT DOOR STATING: "THIS DOOR FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER '�"� MUST REMAIN UNLOCKED DURING BUSINESS HOURS". LEI IERS SHALL NOT BE LESS THE FRONT LIP EXTENDING A MINIMUM OF 30-INCHES IN WIDTH WITH 8-INCHES nix:- EXPlit\ 1. SURFACE SLOPES OF PARKING SPACES FOR THE PHYSICALLY DISABLED � =at � " 58. IF PUBLIC TELEPHONES ARE PROVIDED, THEY SHALL COMPLY WITH _ THAN 1 HIGH ON A CONTRASTING BACKGROUND. THE SIGN SHALL BE INSTALLED BY MINIMUM DEPTH AT THE TOP. TOE CLEARANCE SHALL BE THE SAME WITH AND SHALL NOT EXCEED 1/4-INCH PER FOOT IN ANY DIRECTION. 1 z DISABLED ACCESS REQUIREMENTS. m THE GENERAL CONTRACTOR ON THE STOREFRONT ALUMINUM HEADER FRAME. SHALL BE A MINIMUM OF 9-INCHES HIGH FROM THE FLOOR AND A MINIMUM OF 'N. 17-INCHES DEEP FROM THE FRONT OF THE LAVATORY. 59. PROVIDE 30' X 48' CLEAR SPACE AT TELEPHONE. THE CLEAR SPACE '0. 2. PEDESTRIAN WAYS THAT ARE ACCESSIBLE TO THE PHYSICALLY DISABLED \ 0 Co SHALL BE PROVIDED FROM EACH DISABLED PARKING SPACE TO RELATED `' 18. ALL NEW PRIMARY ENTRANCES TO THE BUILDINGS AND FACILITIES MAY INCLUDE KNEE SPACE UNDER THE TELEPHONE. .. FACILITIES, INCLUDING CURB CUTS OR RAMPS AS REQUIRED. ♦ SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED. 60. THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN 48- ig" 44. 0 0 )1 43. A PROJECTION OF LAVATORY BOWL INTO THE 8-INCH CLEAR SPACE. THEREBY INCHES OF THE FLOOR IF FORWARD APPROACHED AND UNOBSTRUCTED SIDE 0 19. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE 10" • • 3. THE SURFACE OF EACH PARKING SPACE SHALL HAVE A SURFACE REDUCING THE CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN REACH AND 48-INCHES MAX IF SIDE APPROACHED WITH 10 MAX OBSTRUCTED • 0 Nir IDENTIFICATION DUPLICATING THE SYMBOL OF ACCESSIBILITY CONSISTING MINIMUM PASSAGE WIDTH FOR ONE WHEELCHAIR STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, 27-INCHES AT 8-INCHES BACK FROM THE APRON, MEETS THE REQUIREMENT AND 46" MAX WITH 24" MAX OBSTRUCTION. OF A WHITE FIGURE ON A BLUE BACKGROUND, AT LEAST 3 FEET SQUARE. AND ONE AMBULATORY PERSON THE COUNTER SLOPE OF VISIBLE FROM APPROACHING PEDESTRIAN WAYS. FOR PROVIDING KNEE CLEARANCE. ADJOINING GUTTER AND ROAD 61. SIDE APPROACH TELEPHONES REQUIRE THAT THE ENCLOSURE OVERHANG BE O 0 TORFACE IMMEDIATELY ADJACENT 20. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO NO MORE THAN 19-INCHES AND BE AT LEAST 27-INCHES FROM THE FLOOR. G 0 ROTE SHALL RAMP OR BE STEEPER 44. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR q ROUTE SHALL NOT BE STEEPER PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT THAN 1:20 LESS THAN 6 FEET-8 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES i ; , I 1 ; 1 ADJOINING SURFACES SHALL OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR UNDER LAVATORIES. 62. THE CORD FROM THE TELEPHONE TO THE HANDSET SHALL BE AT LEAST �� 'E.S� -fi- __�--- _, _,_�� NOT EXCEED 1:20 X=12 C H I N _ yY_ ,__� _�-____�._ WIDTH OF DOORWAY IS NOT LESS THAN 32-INCHES. 29-INCHES LONG. r HL i I -I----I--------1--. Y= 45. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH --1.---I-..-L-- ! i --- 63. TELEPHONES SHALL BE HEARING AID COMPATIBLE PER ICC/ANSI SEC. 704.2.5 �i-i-{ 1- : LEVEL LANDING ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING / F_�.�____I- ;__ _ -I 1-- 21. WHERE PAIR OF DOORS IS UTILIZED AT LEAST ONE OF THE DOORS SHALL . j Ht OF THE WRIST THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO ii_ EEJ' PROVIDE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WITH THE PANDA EXPRESS INC- -- LE AF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED GREATER THAN 5 LBS. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY 64. TELEPHONES SHALL HAVE PUSH-BUTTON CONTROLS WHERE SERVICE FOR I I- i -a POSITION. CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN. SUCH EQUIPMENT IS AVAILABLE. 1683 Walnut Grove AVE',. I I MEASUREMENT OF CURB RAMP SLOPES 4 SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT Rosemead, California _.4__ --._. ; ____ LEAST 10 SECONDS. 1._�-_ __ _-1-___L-__ {_, 22. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN ADDITIONAL R E REQUIREMENTS:I R E M E I� TS: � 91770 __I- �..__�__a�_- _� PATH OF TRAVEL SHALL BE OPENABLE WITH A SINGLE EFFORT BY LEVER TYPE 1 1 1 - Telephone: 626.799.9898 -i.- -- .t , ' --I A 24" WIDE TACTILE PATTERN OF RAISED HARDWARE, THAT DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING 46. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NOT MORE THAN r I TRUNCATED DOMES COMPLYING WITH SECTION OF WRIST TO OPERATE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER 40-INCHES FROM THE FLOOR. 65. THE CENTER OF RECEPTACLE OUTLETS SHALL BE NOT LESS THAN 15- Facsimile: 626.372.8288 -r - ? -C HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO INCHES ABOVE THE FLOOR OR WORKING PLATFORMS, 1 -_j ! ! 705.3.3.3 THRU 705.3.1.3 OF ICC/ANSI SHALL GRASP THE OPENING HARDWARE. REFER TO SECTION 404.2.7 OF !BC 1 i_ ___' 1-- BE PROVIDED ON THE WALKING SURFACE AT RETAINING WALL IF NECESSARY 47. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL 66. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES 1 1 ; } I L ! I ! I ? '_. THE PLATFORM EDGE, TYPICAL AT EDGE OF SIDEWALK OPERABLE PARTS NOT MORE THAN 40-INCHES FROM THE FLOOR. 23. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO BUILDING OR LANDSCAPING LINE 34-INCHES MIN AND 48" ABOVE THE FLOOR. CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, PROPORTIONS 48. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 7-9 INCHES OF HEATING AND VENTILATING EQUIPMENT, SHALL BE 48" MAX HEIGHT FOR All ideas, designs, arrangement and plans indicated INTERNATIONAL SYMBOL OF ACCESSIBILITY "O ' o `-'O" O THE FLOOR AND LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR THE FRONT EDGE OF THE TOILET SEAT. UNOBSTRUCTED FORWARD AND SIDE REACH. 4$" MAX HEIGHT WITH 10" MAX. or represented by this drawing are the property of O ` O O O O O O 24. Panda Express Inc. and were created for use on r : SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A OBSTRUCTION AT SIDE REACH. 46" MAX HEIGHT AT 24" MAX OBSTRUCTION this specific project. None of these ideas, designs, 0 O 0 O 0, )O O o O 0 = LENGTH OF 60 INCHES IN THE DIRECTION OF TRAVEL AND THE LENGTH OF 48 AT SIDE REACH arrangements or plans may be used by or disclosed to any person, firm, or corporation without the 8.33% 0 0 0 0 x }0 0 0 0 0 8.33%z INCHES IN OPPOSITE DIRECTION OF TRAVEL. SEE DIAGRAM "MANEUVERING written permission of Panda Express Inc. A 4 ' Q " SEAT COVER DISPENSER o o O O o o CLEARANCE 67. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED %�' '/';'iii;, - r /�/i;;, � to TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY 07 = o, O o 0 0 0 //� ��,:;,<,f o o o O 12" 42" G- DISABLED PERSONS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A ''�'%% "' 25. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE / / / Co,% /7' g 0 0 «0 O O O WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO , -% DOOR SWINGS SHALL EXTEND 24-INCHES PAST THE STRIKE EDGE OF THE ° rC�Of�Oe �O(_)OC)O % ;. %'' \ DOOR FOR EXTERIOR DOORS AND 18-INCHES PAST THE STRIKE EDGE FOR COLOR N0. 15090 (N FEDERAL STANDARD 595A. THE INTERIOR DOORS. 1-1/4" TO 1-1/2" REVISIONS: DISPLAY CONDITIONS 48" MINIMUM C GRAB BAR 3 / DIAMETER r, A INTERNATIONAL SYMBOL OF ACCESSIBILITY 26. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2-INCH LOWER THAN THE ROLL PAPER HOLDER 48" A THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4- INCH AND r� l ' --#SIDEWALK CURB 1/2-INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 ' - _ WATER CLOSET rr, _ N. 27. THE BOTTOM 10-INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING DOORS c„ WALL , hill WWII _ 0 r BUILDING OR LANDSCAPING LINE SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE _1 Fil ■" OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS n j os 5 -` `.HANDLE ` TRUNCA DE DOMESECOMPLYING WITS I SEDCTION CONDITION. SHALL BE�NSTARLOED ON M DOORS ARE USED, A POLISHED SIDE OF THEODOOR, WHICNSMWILL L ' / i , ` 11 ♦ �`= o �- ARMREST 705.3.3.3 THRU 705.3.1.3 OF ICC/ANSI SHALL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING 1-1/2" . LAP BE PROVIDED ON THE WALKING SURFACE AT A TRAP OR HAZARDOUS CONDITION. 12 'r '�' -f 1 / / „�� THE PLATFORM EDGE, TYPICAL SEAT • tI ~ 30" 30" 36" 19" \ dank.. f o 28. A NARROW FRAME WITH A BEVELED TOP (30 DEGREES MAX. BEVEL TO VERTICAL -1 1- -1 / / i . w Ii�. �. m PLANE) INSTALLED AT THE BOTTOM OF THE GLASS DOOR (WITH NO SIDE TOILET SIDE ELEVATION GRAB BAR ISSUE DATE: N a, `�� "� FRAMES) MAY BE USED IN LIEU OF PROVIDING THE REQUIRED 10- INCH -\ TOE tai..�' J q v UNINTERRUPTED SURFACE AT THE BOTTOM OF THE DOOR. ACCESSIBLE SANITARY FACILITIES 1sT PERMIT APPLICATION 01/09/09 o x. 111 -OOOC�- :)f� 00 2ND '� '� \ -> 0 O o j 0 0 29. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR EXTERIOR 8 3RD o O O C O DOORS AND 5 LBS. FOR INTERIOR DOORS. SUCH PULL OR PUSH EFFORT BEING /" 10% �OOOOC��o0 0��0 10% 48" CLR. 4TH .► D��0 0 O{,O{�0��0 n' -.. APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF / / ) 0) 0 O 0 0 = SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR 5TH t 1 6" 42" OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE 6TH / • DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE �-I I �_ C -----,-_�, ) \ INCREASED NOT TO EXCEED 15 LBS. +� \ �, _ _- >, .� r 1- ` D CORRIDORS AND AISLE: 48" rietfiirN ----� -..g"- 6 SIDEWALK CURB G / J 2" MAX. FOR METAL TABLES ��;�; D co _ 4 MAX. FOR WOOD TABLES N '-, "it-4:41' +� * 30. FLOOR SURFACES SHALL BE SLIP-RESISTANT. _- o w 1 „Hu DRAWN BY: SAR Cr 1 WHERE BOTH CLOSER AND LATCH ARE PROVIDED _, r, _I ` ''��jL �•, Y ��- 31. EVERY PORTION OF EVERY BUILDING IN WHICH ARE INSTALLED SEATS, - I `r 1 ti " 1 \. N. `(- 1 \ _n_ I TABLES, MERCHANDISE, EQUIPMENT OR SIMILAR MATERIALS SHALL BE / I " " �' I,--r- ---,V PROVIDED WITH AISLES LEADING TO AN EXIT. J �m _ _ _ MINIMUM CLEARANCES FOR SEATING AND TABLES 10 i I I -f ` PANDA PROJECT#: S4-09-D2116 4 DIMENSIONS OF ADULT-SIZED WHEELCHAIRS ! 18" I I - 32. EVERY AISLE SHALL BE NOT LESS THAN 3 FEET WIDE IF SERVING ONLY ONE / co 54" MIN f 18 min 12" min.* I I -4- SIDE, AND NOT LESS THAN 3 FEET 8 INCHES WIDE IF SERVING BOTH SIDES. / ,1 ` ARCH PROJECT#: 0821 I SUCH MINIMUM WIDTH SHALL BE MEASURED AT THE POINT FARTHEST FROM AN I 1 1 EXIT, CROSS AISLE OR FOYER AND SHALL BE INCREASED BY 1 1/2 INCHES 1 I I _ MIRROR CURB RAMPS, WALKS AND SIDEWALKS: FOR EACH 5 FEET IN LENGTH TOWARD THE EXIT. CROSS AISLE OR FOYER WITH 1 �' I I I co I' I I• I CONTINENTAL SEATING SIDE AISLES SHALL BE NOT LESS THAN 44 INCHES IN 1 I I I i 7" MIN. 4. WALKS AND SIDEWALKS SHALL HAVE CONTINUOUS COMMON SURFACE, NOT WIDTH. �\ I I �� a 19 Max- LEVER ARCHITECT: INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2- „ \ r___��__ __-4.___, -1 i/ INCH AND SHALL BE A MINIMUM OF 48-INCHES IN WIDTH. (A) FRONT APPROACH, (B) FRONT APP OACH \ I / 1111111ftwa... lie PULL SIDE PUSH SIDE I z' (- _" ., R. P G 5. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 SANITARY F-A C I L I T I E S: I I )1111.,_%, l�/�,t, PROTECTED PIPING VERTICAL TO 20 HORIZONTAL (5% GRADIENT) IT SHALL COMPLY WITH THE " o --- -- 8" MIN, In PROVISIONS FOR PEDESTRIAN RAMPS. 33. ACCESSIBLE SIGN CONTAINING TACTILE CHARACTER IS PROVIDED AT DOOR, THE I -, I Ittt.. I �'�' Z g. = REITER DESIGN GROUP r- SIGN SHALL BE ALONGSIDE THE DOOR ON LATCH SIDE AND AT DOUBLE DOORS, - o THE SIGN SHALL BE RIGHT OF THE RIGHT HANDED DOOR. THE SIGN CONTAINING I `� I 6. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4-INCH PER FOOT. E 1 n -,,,,'�_ ■_-'--„�'_ - rn tr.) ARCHITECTS, INC. TACTILE CHARACTERS SHALL HAVE 18" MIN BY 18" MIN. SPACE ON THE FLOOR +___ '`1 Z c., N 7. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED c CENTERED ON SIGN. THE SIGN TACTILE CHARACTER SHALL BE 48" MIN AND 60" ���`� 7965 SW CIRRUS DRIVE 1/2-INCH. WHEN CHANGES IN LEVELS DO OCCUR, THEY SHALL NOT BE BEVELED I _E MAX ABOVE FLOOR. ----- ' BEAVE ETON,OREGON 97008 WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT I d " 60" MIN (503)574-3036 FAX(503)574-2916 EXCEEDING 1/4-INCH MAY BE VERTICAL. 36" min 42" min 'n 34. CLEARANCE AROUND THE WATER CLOSET SHALL BE 60 MIN MEASURED 1 MIN 'Mill 1 iiiiiiiiiiiiiiii PERPENDICULAR FROM THE SIDEWALL, AND 56" MIN. MEASURED PERPENDICULAR ' s" Max. FROM REAR WALL. NO OTHER FIXTURES OR OBSTRUCTION SHALL BE WITHIN 8. WHEN CHANGES IN LEVELS GREATER THAN 1/2-INCH ARE NECESSARY, THEY SHALL COMPLY I' 'I I' 'I WATER CLOSET CLEARANCE WITH THE REQUIREMENTS FOR CURB RAMPS & PEDESTRIAN RAMPS. 35. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS <N E E CLEARANCES 0 MINIMUM REQUIREMENT FOR ACCESSIBLE SANITARY FACILITIES 9 STAMP: AOD Akejo, 9. NOT USED {C} HINGE APPROACH, (D) HINGE APPROACH, AN AUTOMATIC CLOSING DEVICE OPENING WIDTH OF 32-INCHES AND SHALL HAVE A CLEAR UNOBSTRUCTED WHEN LOCATED AT THE END AND 34-INCHES `1' 10. CURB RAMPS SHALL BE CONSTRUCTED AT EACH CORNER OF STREET PULL SIDE WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 INTERSECTIONS AND WHERE A PEDESTRIAN WAY CROSSES A CURB. PUSH SIDE DEGREES FROM ITS CLOSED POSITION. r:1 GEORGE T. ROBISON`� 68. EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES C� 11. CURB RAMPS SHALL BE A MINIMUM OF 4 FEET IN WIDTH AND SHALL LIE � 54" MIN � r � 36. EXCEPT FOR DOOR OPENING WIDTH AND DOOR SWINGS, A CLEAR UNOBSTRUCTED CRAB BARS: IMMEDIATELY ADJACENT BY TO AND VISIBLE IZFROMIGEACH PERMANENTLY OR SPACE DCaNSISTING • eft-Tif2(44-9 GENERALL Y, IN A SINGLE SLOPED PLANE, WITH A MINIMUM OF SURFACE r -I ACCESS NOT LESS THAN 44-INCHES SHALL BE PROVIDED TO WATER CLOSET OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE PORON , . WARPING AND CROSS SLOPE. z I 49. GRAB BARS FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED ' z I COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE SPACE IMMEDIATELY FOR 250 LBS. PER LINEAR FEET LOAD. BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 SQUARE INCHES IN 2520 12. THE SLOPE OF CURB RAMPS SHALL NOT EXCEED 1 VERTICAL TO 12 z I IN FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN ARE AND WHEN IN PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM OF ��..,,,, HORIZONTAL. THE SLOPE OF THE FANNED OR FLARED SIDES OF CURB " . I 48-INCHES AS MEASURED AT RIGHT ANGLES TO THE COMPARTMENT DOOR IN IT'S 60-INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED '4' 0 RAMPS SHALL NOT EXCEED ONE VERTICAL TO 10 HORIZONTAL. 24 min CLOSED POSITION. 50. GRAB BARS SHALL BE LOCATED ON EACH SIDE, OR ONE SIDE AND THE BACK GRADE. AN ADDITIONAL SIGN SHALL ALSO BE POSTED AT ENTRANCE TO v� 1 OF THE PHYSICALLY DISABLED TOILET STALL OR COMPARTMENT AND SHALL BE OFF-STREET PARKING FACILITY OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM `C - 13. A LEVEL LANDING 4 FEET DEEP SHALL BE PROVIDED AT THE UPPER END OF I' ,I SECURELY ATTACHED 33-INCHES ABOVE AND PARALLEL TO THE FLOOR. EACH STALL OR SPACE. THE SIGN SHALL NOT BE LESS THAN 12-INCHES BY 0)- 0. EACH CURB RAMP OVER ITS FULL WIDTH TO PERMIT SAFE EGRESS FROM THE I' 'I 37. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 18-INCHES IN SIZE WITH LEI HERING NOT LESS THAN 1-INCH IN HEIGHT. REFER RAMP SURFACE, OR THE SLOPE OF THE FANNED OR FLARED SIDES OF THE INCHES AND A MAXIMUM OF 19 INCHES MEASURED TO THE TOP OF TOILET TO DETAIL 4/A-0.3 CURB RAMP SHALL NOT EXCEED ONE VERTICAL TO 12 HORIZONTAL SE(F)r (F) LATCH A P P R 0 A C H, 51. GRAB BARS AT THE SIDE SHALL BE AT LEAST 42-INCHES LONG WITH THE FRONT END POSITIONED 24-INCHES IN FRONT OF THE WATER CLOSET STOOL, AND GRAB PANDA EXPRESS 0 14. THE LOWER END OF EACH CURB RAMP SHALL HAVE A 1/2-INCH COUNTER PULL SIDE 38. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL BARS AT THE BACK SHALL BE NOT LESS THAN 36-INCHES LONG. N SLOPE IMMEDIATELY ADJACENT TO RAMP OR ACCESSIBLE ROUTE SHALL NOT NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. o BE STEEPER THAN 1:20 CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE 69. AT KITCHEN: SINKS, FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE TIGARD TOWN SQUARE (E) HINGE APPROACH, OF THE TOILET AREAS, NO MORE THAN 44-INCHES ABOVE THE FLOOR. THE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING 15. THE SURFACE OF EACH CURB RAMP AND ITS FLARED SIDES SHALL BE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 52. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 3 SLIP-RESISTANT AND SHALL BE OF CONTRASTING FINISH FROM THAT OF PUSH SIDE POUNDS. 1-1/4 INCHES TO 1-1/2 INCHES OR THE SHAPE SHALL PROVIDE AN OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS THE ADJACENT SIDEWALK. EQUIVALENT GRIPPING SURFACE. SHALL BE NO GREATER THAN 5 LBS. LEVER- OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE 16230 PACIFIC HWY. SUITE 100 16. 24" WIDE TACTILE PATTERN OF RAISED TRUNCATED DOMES COMPLY WITH r- DESIGN. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS FOR AT ,�, 39. WHERE URINALS ARE PROVIDED, AT LEST ONE SHALL HAVE A CLEAR SPACE 53. IF THE GRAB BAR IS MOUNTED ADJACENT TO A WALL, THE SPACE LEAST 10 SECONDS. TIGARD, OREGON SECTIONS 705.3.1.1 THRU 705.3.1.3 SHALL BE PROVIDED ON THE WALKING 30-INCHES WIDE X 48-INCHES LONG IN FRONT OF THE URINAL. (Ti SURFACE AT PLATFORM EDGE z BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES. a 40. WHERE URINALS ARE PROVIDED, AT LEAST ONE WITH A RIM PROJECTING A o w 54. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT SHALL BE vi 24" MIN `- MINIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE PROVIDED. FREE OF ANY SHARP OR ABRASIVE ELEMENTS. U 41. A CLEAR FLOOR SPACE 30-INCHES WIDE X 48-INCHES LONG SHALL BE 55. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. cx PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH I 'I CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND 56. EDGES SHALL HAVE MINIMUM RADIUS OF 1/8-INCH. T..2 • SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. 2 Z.--1 *48 MIN WHERE (0) LATCH APPROACH, CLOSER IS PROVIDED 57. WHERE LOCKERS ARE PROVIDED, AT LEAST ONE AND NOT LESS THAN ONE o PUSH SIDE PERCENT OF ALL LOCKERS SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED. A PATH OF TRAVEL NOT LESS THAN 36-INCHES IN CLEAR WIDTH (I,, SHALL BE PROVIDED TO THESE LOCKERS AND A CLEAR SPACE FOR A CIRCLE HANDICAPPED NOTES WITH DIAMETER OF 60-INCHES. N co MANEUVERING CLEARENCE AT SWINGING DOORS 0 O • • . • • r •r • • r • • --,,p _ FA'A-)4 i Fryer timer installed Banner rod painted old and gold balls installed N 4c) _ -- EW STORE FINAL PUNCH LIST 1 ry P g g _�_...._�____._,___________� ::::�-C:::::: .:.G:: -. -��-� G�CI�������" -�� Ansel pull station is in n . Building exterior ...G.........*R...-. C t 1e................................atria.. p inspected and tagged Decor installed per plans -- - Date t ' '_.__ ` — Lintels painted on masonry buildings All equipment tested and operational Table base core drills neat, no tile chips, filled flush with tile r I i j _ V' Store Name All gaps between building and walks caulked and allow for Restraint cables installed on fryers top for easy cleaning Store Number i ; drainage All drain lines installed with proper air gap to floor sink and Wall mural installed, caulked to trim and clear corner guard Q.. (.0 General Contractor i i � i All pipes, conduits, electrical boxes, and bollards are painted larger pipes centered in floor sink to avoid spash installed at outside corner. • e O • © Project Manager ( 1 i Building lights installed and aimed (at Night)for proper Grease cups and hood joiner installed on hood Install clear plastic comer guards (2'high)on all outside 0 4 1 ; coverage Glass doors on walk-in cooler installed and operational corners Q Building lights are level and timer set properly All pipe and conduit wall penetrations completely sealed and Pepsi and tea equipment installed and calibrated Item Responsible to g g p P y G 4 Area i Item Description Date Completed Awnings are installed and cleaned escutcheons installed Ice machine on top of Pepsi machine installed and operating, "PA_ 4 OK complete Properly install 1"x 1" SS angle at hood to wall unction, side closure pieces installed, sealed to counter �:: :: Building signs are installed and timer set properly P Y 9 1 p �` General �G� PR�� {3#�i��` -�� -:�Paa� � j' S - :: --•::::::::.;,::•:•,::•:.:...,,,i.: -:------- Sidewalks are clean and level with no trip hazards install with SS rivets Pepsi drain pipe insulated C H 1 Final Certificate of Occupancy in hand Sidewalks sealed at patio areas Drink sign installed, clean, and operational All final inspections completed and signed off Rear door painted Bolt down SS sleeve at SS outlet panel for underground elec A/C diffusers and returns installed per plan _ Start-up Health inspection completed and signed off secure and stable, no chips on file Rear door viewer installed SS rail installed, — As-built drawings complete PANDA EXPRESS INC. Operations Manuals provided-Electrical/HVAC/Plumbing Rear door anti-break-in panel installed Thermostats and remote test switches labeled Subcontractors List-Phone Number/ Contact Names Heavy duty rear door stop/hold open installed Zolatone paint coverage and texture per sample 1683 Walnut Grove Ave. General Contractors Written Warranty Procedure Door sweeps installed All wall finishes clean and free from defect Rosemead, California General Contractor I Sub-Contractor Warranty Letters Exterior music speaker installed Window shades installed (roll out, away from glass)and 91770 Roof Warrant Exterior cameras installed and not view is not blocked operational, cord clips installed. Telephone: 626.799.9898 Y Address lettering is installed pre code Seal between wall and window/door frames HVAC Air Balance Facsimile: 626.372.8288 - Patio furniture in place with table and umbrella base bolted to Kitchen :' :: PRG Other:=::: 0::: ::Pal ida: Seal rubber base to floor at booth seating Equipment Serial Number sheet completed concrete FRP installed on all walls, clean, with no bubbles, film V Ancor display case base to floor and seal ADT installation complete and system operational Clean excess grout at wall tile' Chairs unwrapped and in place removed _ 9 Fast Track Timer installed and operational , ->- � . Muzak System installed and operational -- Patio"marquee" complete Ceiling grid level with no bends, tiles clean and tight, joint to Ensure beverage counter back and side splash align with GNISEC Closed Circuit TV Camera installed& operational Hose bib installed wall sealed with caulk _ wainscot All ideas, designs, arrangement and plans indicated P - Cut off nails below roof sheathin at o n ceilin or represented by this drawing are the property of Phone Line and DSL live Electrical outlets installed on building corners in A/C diffusers and returns installed per plan 9 Pe 9 Panda Express Inc. and were created for use on weatherproof box Stainless steel corner guards installed, caulked in place Install door decals and stops this specific project. None of these ideas, designs, Managers Trained on Thermostats and Remote Enunciators arrangements or plans may be used by or disclosed Stucco/ EIFS installed in professional manner with no All light switches and outlets have SS covers Ensure all glass is clean and break free to any person, firm, or corporation without the NCR Hook up register& computer - written permission of Panda Express Inc. cracks or patches visible All light switches and outlets are tabled Artwork glued to the walls. Start-up form completed for CaptiveAire heat and evap units - Proper sealant installed around window and door frames All equipment installed, level, and operational. Sealed _ , All pipe and conduit wall penetrations completely sealed around all joints. Keys to OPS , All wall shelving installed and caulked all around - In-use water-proof cover installed on outlets at 2-comp sink ' REVISIONS: Walk-in cooler and freezer base sealed to floor _Walk-in cooler and freezer up and running I - A Condensate lines are insulated and heat tape is installed on Additional Items ! = : G Other Pan a:: A P freezer Site { j GC PR :: let::::GC: : ::Pa a: - - _ - n Cooler running at 38 degrees and freezer at-10 degrees A Approaches/Curb-cuts installed per plans : : ' Restrooms j :: C::: : t e :: :CC:: ::=::Pe ; : Freezer defrost cycles set at 4x per day 5 Asphalt pavement installed and smooth - ....... ....... ....... ........... ........... No areas of ponding or holding water All fixtures operational Soap and paper towel dispensers installed and filled All accessories installed and functional, keys to OPS Product shots, training aids, bulletin boards installed Lot striping completed per plans - A Lot striping and lettering free of defects Door closes properly and locks (if applicable) Soap dispensing system installed at mop sink on it own Curbs complete and free of defects Caulk all dissimilar materials, fixtures to tile, tile to door water supply Landscaping complete, beds free of weeds/papers frame Soap dispensing system installed at 3-compartment sink on , Trap primer for floor drains installed with access panel facing it own water supply Irrigation operational w/proper coverage on plants and grass kitchen Irrigation timers set for non-peak watering times - ISSUE DATE: Site lights installed and aimed (at Night)for proper coverage Light occupancy sensor installed and operating correctly CO2 tank in place and remote fill box installed, key to OPS _ I Site light timers set for correct ON and OFF times - Exhaust fan operational and properly controlled by sensor in Hot water heater running and maintaining temperature. I 1 { t 1 1sT PERMIT APPLICATION 01/09/09 Trash enclosure complete with latch and hold opens either restroom Pipes insulated, drain pan installed, all per code 2ND Correct signage on doors Rear door painted, silencers installed, hardware correct Trash bins and waste oil recovery tanks in please HC pipe wraps installed properly Electrical panels labeled outside and have legends inside 3RD Handicap signage installed ' 4TH Site signs installed and operation with correct timer setting HC grab bars installed properly Time clocks labeled and set for proper operation Floors slope to drain Trap primers installed on all floor drains 5TH D/T speaker, sign, menu boards, and clearance bar installed Stall partitions installed correctly and door swings per code Lockers in place, legs removed, screwed to wall 10" aff 6TH Site clean, all materials removed, parking lot swept , Construction trailers, containers, dumpsters, removed -� Kick plates installed on doors Floor has been test flooded to insure proper drainage 1 Door silencers installed on frames Mop has SS "Z' channel installed under FRP and over rim Temporary toilet removed Surrounding property cleaned and dressed off Tile pattern correctly installed Mop Holders and other accessories are installed Mail box installed(if applicable) - Excess grout cleaned off top of tile at painted drywall Sinks anchored to walls with SS screws and sealed all Cleanouts installed on grease interceptor 1" cut off door bottom around DRAWN BY: SAR Bollards installed per plan and painted Mixing valves installed and set on hot water at lavatories Hot water pipes insultated Knox-box installed (if applicable) ' All pipe wall penetrations completely sealed and Use SS rivets to secure base at WiC/WIF, extra at door escutcheons installed Floor sinks installed in correct location per plan Bike rack installed (if applicable) All protective wrap removed from lights and accessories All floor sinks have correct grates installed, cut to allow - proper drain (if applicable) PANDA PROJECT#: S4-09-D2116 All drain lines installed with proper air gap to floor sink and ARCH PROJECT#: 0821 larger pipes centered in floor sink to avoid spash Hood control panel frame installed Roof :GC::::PRG: Ot ier::::GC::: ::Pa a: ARCHITECT: Hose bib installed for cleaning equipment :CC: : E ": : C :::-.E-Pd :- RPG Service area :: Vent stacks installed per plan with required clearances Counter set level, trimmed, and base installed. Caulked to Exhaust fan has grease pan installed properly . walls Exhaust fan has hinge kit installed to allow full opening POS, printer, credit card machines installed and operating RE l TE R DESIGN GROUP Flexible conduit installed to allow the exhaust fan hinge to Caulk all dissimilar materials Manager station g : GC:: :PRG: Other : GCS: :Pa €a:= open for cleaning g ARCHITECTS, INC. Gas lines to all equipment painted yellow Menu board installed, painted flexible sealant to wall, sticks Desk, overhead cabinet, file cabinets installed and sealed No obstruction in front of scuppers (if applicable) out 1/2" in front All time clocks, switches, annuciators, and thermostats are 7965 SW CIRRUS DRIVE Roof drain and overflow have grates installed (if applicable) Security cameras installed and operational labeled and OPS has been instructed on operation BEAVERTON,OREGON 97008 Roof inspection by certified inspector (if applicable) HME intercom installed and operational (if applicable) Computers, printer, fax, music system, DSL, and phone (503) 574-3036 FAX(503) 574-2916 • - Floor tile installed, level, cleaned, and grout lines straight installed and operational _Roof has been tested flooded with water and no leaks Floor slope to drain Security system installed and functioning Refrigeration units on platform and secured down Floor drains cleaned, flushed with water, and drain well Safe anchored, keys to OPS _ . . , . . MUZAK satellite is weighted and on membrane sheet-wire All equipment installed, level, and operational. Sealed Camera system installed and operational, box bolted down penetration properly sealed STAMP: ARe A/C condensation drain lines piped to floor sink in kitchen around all joints Ceiling level, clean, ainted, and free of all scratches and A/C condensation drain lines have union at unit and proper scuffs P GEORGE T. ROBISON 'C" ) vent and trap FRP caulked to ceiling r) Replace all HVAC filter with new just prior to turnover _ Stainless steel above hood and cooler enclosure caulked to MAU overflow drain line piped to floor sink inside of kitchen ceiling, SS rivets and no gaps • MAU auto anti freeze drain-down valve wired and operational PORT D, OREGON , Stainless steel outlet wall installed correctly and sealed 2520, and piped to floor sink inside of kitchen (if applicable) Ceiling grid level with no bends, tiles clean and tight ir,, Roof is clean of all materials and debris , ,Z7- t� All steam pans installed, tested, and controls correct pan Dining ::GC: _ 'Rfiiir :: t := : :Pafii: �! Allroof units are properly labeled I :.... ......... . ...•::::::::::::::::: -.:::::•,::::::::::::•.. F QSign power supplies in troughs or raceways and all holes Sneeze guard glass installed correctly and lines up Ceiling, trusses, conduits, and other items painted, free from o properly sealed Silicon bumpers installed on corners of sneeze guard glass scratches and scuffs, and clean (if applicable) ,n All conduits, gas and water lines properly supported i Floor sinks installed in correct location per plan Ceiling grid level with no bends, tiles clean and tight, joint to o Work Lights on HVAC Units Floor slopes away from wall under cook line and front wall sealed with caulk (if applcable) o GFI outlets installed on HVAC units - counter to avoid water ponding at wall base Light all operational PAN DA EXPRESS o All access panels installed and properly sealed All floor sinks have correct grates installed, cut to allow Lighting is aimed at decor items cv a Roof walk pads in place (if applicable) proper drain (if applicable) Hanging lanterns level at 9'-2" aff and lamp is centered in TIGARD TOWN SQUARE Parapet flashing properly sealed and complete Stainless steel corner guards installed, caulked in place middle of lantern 3 ' _ D/T timer equipment installed and operational (if applicable) Caulk all dissimilar materials, painted walls to tile(clear), No water ponding on roof -a D/T intercom system isntalled and operational (if applicable) and around window frames d - A/C diffusers and returns installed per plan Tables, booths, chairs in place, tops screwed to bases with o - Light switches labled 8 screws, booth base installed. 16230 PACIFIC HWY. SUITE 100 '--' - Outlets labled Music system installed and operational TIGARD, OREGON a in-use water-proof cover installed on outlets at cookline CCTV system installed and operational, no views blocked o Exhaust hood smoke tested and balanced Floor tiles installed level, clean, with straight joint lines Grout joints sealed per specifications _ U < i '0 'RI Q T.4 . 0 0O cry N FINAL PUNCH LIST CD _ • •• • ,, e • .• • • ._ . • • • • • l'S. ---...E_X- .. e0r7 i (f) AiLty-� e O O 0 p 0 0 G o 'AA. << T CH1t�ES PANDA EXPRESS INC. • 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.799.9898 Facsimile: 626.372.8288 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. • SW PACIFIC 1-4W REVISIONS: ---- ___________ , A A o o o _ o a A 1 — �-- _.:- __ _-.-- C� 0 0 . �. # O TRANS- 0 . b. e. PA n n •n a s • 9 F jUt:i1 _ i I _ ISSUE DATE: EXISTING BUILDING f f-= 1sT PERMIT APPLICATION 12/18/08 z 2ND 1 ■ . a I 0 3RD iii #' : 4TH i� � 5TH 6TH • . Al.fd C:) .. I-- PANDA 4.�-- NEIU S(DEtd)ALK EXPRE55 ,,;, By LANDLOSUITE 1OO Ellin a,r,•111--_, 0111): – == —, D RAW N BY: SAR _ iii.� ,i j . . T ' ,. \,.., 8 1 PANDA PROJECT#: S4-09-Q2116 ...boil. I.. .7 _} ..,...... ARCH PROJECT#: 0821 N/ . EXISTING ACCESSIBLE PARKING SPACES ARCHITECT: R PG 0 0 0 0 0 \c,scI REITER DESIGN GROUP ARCHITECTS, INC. 7965 SW CIRRUS DRIVE BEAVERTON,OREGON 97008 (503) 574-3036 FAX(503)574-2916 STAMP: 0 c..,`c.°) GEORGE T. ROBISON n y• •i'D 44 RORT�.ND,2s2o 6IZEGON 0 11.7>4, 0 ce * (53 0 1141P 0 0 0 0. 0 0 PANDA EXPRESS 0 "' TIGARD, OREGON co ...14 Z3 0... 16230 PACIFIC HWY. SUITE 100 <,...is 0 _,_,------ - TIGARD, OREGON D O. O v) Z U ce ..'t N fcrL\c) A.0 . 1 © ? eShT i d' - ,.., OVERALL SITE PLAN N Do ___ _ _ _ _ - - FINISH SCHEDULE S3-A10-FSO1 02/14/07 • ROOM NAME FLOOR , BASE WALL CEILING = T-90 6"x24» TILE T-96 6"x12" PORCELAIN TILE P-9E PAINTED GYP.BD. 100 DINING ROOM C1 2'X2' SUSP. GRID T-91 4"x24" TILE T-98 12"x24" BLACK TILE ACOUSTICAL TILES 1-93 6"x 12" PORCELAIN TILE EXIST. AWNING `__ 1-92 6"x24" ACCENT TILE W/COVE BASE FOR i E T-97 12"x24" RED TILE C3 GYP. BD. SOFFITS REMOVE (E) MTL. V SERVING & BEV. COUNTER WALL AT DRINK STATION P-9B GYP. BD. SOFFITS ROOF 4 REPLACE QT2 6"x6" CONT. 3/8" RAD. W/ FABRIC PER QT 6"x6" CONT. QUARRY TILE / 34I_9 I/4" 9/A30 (1,01) SERVICE MIN. (KITCHEN EQUIP ON P-9D SMOOTH WASHABLE PAINT C3 GYP. BD. W/ / / O AREA QT1 IN HIGH TRAFFIC AREA 6" NSF APPROVED LEGS T-95 8"x13" YELLOW TILE P-9As SMOOTH WASHABLE PAINT 4. 0 v T-96 6"x12" PORCELAIN TILE 91---,001----- 11'-9 3/4" 2'-9 1/2 11 -2 AI\ o �„ • — — -- _ _--/ - r / /QT 6"x6" CONT. QUARRY TILE QT2 6»x6" CONT. 3/8" RAD. __----_._--___---_.__-- ,-_ -- _--- - _- / 4 102 MANAGER QT1 (N HIGH TRAFFIC AREA MIN. (KITCHEN EQUIP ON P-9As GYP. BD. C2 W X4' SUSP. GRID D - -� • OFFICE 6 NSF APPROVED LEGS WP1 FRP PANEL WASHABLE VINYL _ — — — �� — 5 0 / 3 -! y 3 -1 y G Q COATED GYP. BD. PANELS d -t ,� t> I 6" HIGH CONC. PAD Fes" NIGH CC*NC. PAD ', _> " QT2 6"x6" CONT. 3/8" RAD. FOR C20 TANK FOR WATE NEATER F 103 KITCHEN QT 6x6 CONT. QUARRY TILE MIN. (KITCHEN EQUIP ON WP3 S.S. BEHIND COOK LINE C2 WASHABLE VINYLID I COVER W/ S.S. COVER w�g.5. C H I ��5 QT1 IN HIGH TRAFFIC AREA 6" NSF APPROVED LEGS WP1 FRP PANEL I i _ COATED GYP. BD. PANELS D ( I • T 6"x6" CONT. QUARRY TILE QT2 6"x6" CONT. 3 8" RAD. \ D I ( _ ci 04 STORAGE Q Q MIN. KITCH N / WP1 FRP PANEL C2 2X4 SUSP. GRID 04 r QT1 IN HIGH TRAFFIC AREA (KITCHEN EQUIP ON WASHABLE VINYL WALL PANDA EXPRESS INC. 6 , , Q ALL LEGEND NSF APPROVED LEGS COATED GYP. BD. PANELS I ___A _ _ 1683 Walnut Grove Ave. CH-3-5) WALK-IN QT 6"x6" CONT. QUARRY TILE SS/ALUM. EXT S.S. ALUM/GALV. STL ELEC. r 1 -- /^ `��" _ i EXIST. E XTC R I O R WALL_ Rosemead, California PANELS -� r 91770 COOLER QT1 IN HIGH TRAFFIC AREA INT, ALUM/GALV. STL ' r t Telephone: 626.799.9898 /'�i%-1 //%/'f"'�i NEW WALL 105 WALK-IN GALV. STL. SS ALUM. EXT S.S. ALUM/GALV. STL B ,_ Facsimile: 626.372.8288 / 1. �, r" FREEZER INT, ALUM/GALV. STL A22 - '' lOb `. T N 104 - m N ,d A C MEN'S W 1 T-90 6"x24" TILE T-94 6"X 12" = ; I I 10 STORAGE Co �� -ROOM -` � :� �, T-95R 8"X13" PORCELAIN TILE C3 GYP. BD. W/ _ __r_ __.; I NEW LOW WALL 1 06 MEN T-91 4"x24" TILE PORCELAIN TILE W/ 1-95W 8"X13" PORCELAIN TILE P-9As SMOOTH WASHABLE PAINT 6, ! A22 I D cQ 3/8 RAD. COVE A22 All ideas, designs, arrangement and plans indicated — -,--r---1---- ; A22 or represented by this drawing are the property of Panda Express Inc. and were created for use on -_ _---- > I' WALK--IN BOX PANEL -f -2 3._�*" (0'-0 41iP D3 this specific project. None of these ideas, designs, > arrangements or plans may be used by or disclosed f to any person, firm, or cor oration without the 1-90 6"x24" TILE T-94 6"X12" T-95R 8"X13" PORCELAIN TILE C3 GYP. BD. W/ PROVIDE 6" SOUND f" :, Y P (1-67) WOMEN T-91 4"x24" TILE PORCELAIN TILE W/ 1-95W __ _ \ �'" - -: 2� / NOTE: THE FOLLOWING STAINLESS STEEL written permission of Panda Express Inc. INSULATION IN DEMISING '//" '` " \ 8 X13 PORCELAIN TILE P-9As SMOOTH WASHABLE PAINT =y \ _ �:.�___, �i ' 3 8 RAD. COVE '� `� PROVIDED BY OWNER--INSTALLED BY G.C.: PARTITION, TYP. ; !f IlllIlilil c 0 %;z` ,•W3 1\9" 1 . WP3 PANELS C 1 2X2 SUSP. GRID ::�_ r _�_- 0 I1i T-90 6x24" TILE T-94 6"X12" ' �' _� 2. PANEL DIVIDERS AT WP3 T-95R 8"X13" PORCELAIN TILE - ACOUSTICAL TILES r --� ...,. m �, 108 VESTIBULE T-91 4"x24" TILE PORCELAIN TILE W/ 1-95W 8"X13" PORCELAIN TILE 17Y/'' 1 = 07 < EXIST_ AWNING 3. WALL END CAP AND HEADER AT WP3 REVISIONS: 3/8" RAD. COVE C3 GYP. BD. W/ iT, Eii -- r P-9As SMOOTH WASHABLE PAINT 5 I ---_ I ` ~ _ -�, --_T © WOMEN'S 108 REMOVE (E) MTL. 4. INSIDE CORNER AT WP3 TO WP2 < i_ 105 � • ` ; ' ROOF REPLACE 5. FLASHING AT TOP OF BASE AT WP3 A -.4- ' E qv G ROOM VESTIBULE A22 /� ALK-IN I UJ/ FABRIC PER 6 4' WP2 PIECE AT END OF HOOD 2 °I ,REEZER ; -I t_ T 3'- -- ''�, H S'-�" D3 I 5' �" 9/A3.0 .1 36X84" i i h( I a DOOR SCHEDULE S3-A10-DS01 03/18/02 ` , ' ALL OTHER STAINLESS STEEL BY G.C. 4 4;- ? ==� • a., n ,'oLt7NER ; G.C. TO PROVIDE VERIFIED DIMENSIONS • NO MANUFACTURER MFG# SIZE FRAME FACE/EDGE THK. CORE LITE RATE HOW INSTALL BY GLC ;;; �, �v ti:-<, v x Y<;<r. < — - ,� ,�. x�\. ��;t y;,-�y,' Y:�= ,� — START OF PROJECT. �` PROVIDED BY TEMP. °°rr.0,,,,, f " 1 t/ — — yr.: �-r !'vv.w.v.v.^. •nnw::.w•:vrm•'tw•,m••,+v:mv:.vrt:wx bivx:xw:n:•:•rx.x••rxii•:,q, xtg'{ ': �_ - - - -� ` TO OWNER AT T D1 - PROVIDED BY _';�,' f, �--- - ---- _ / n GLASS DOOR LANDLORD 6-0 x7-0 ALUM. CLEAR ANODIZED GLASS GLASS LANDLORD ;,-- ___7_____ ___ -._ _._-----.---_-------------___-- -.-- 6 �r W6 - =�� NEW STOREFRONT D2 PROVIDED BY ALUM. CLEAR ANODIZED - GLASS TEMP. - PROVIDED BY `� ' r "i GLASS DOOR LANDLORD 3p-0,,x7,-0" a ' SYSTEM - GLASS LANDLORD 8 m / NOTE. ' _ ___ BY LANDLORD) TO INSTALL MIN 3 " WALK-IN ' ; ,; o..._. " i D3 CECO - 3-0 x7-0 H. METAL S.C. WD MAPLE FIN. 1 3/4" - - HW-4 AT WOMEN'S 107 * _, \ n - / ( L „ _ " 105 ( 36X84 A22 G.C. 1/2 NON—COMBUSTIBL W/ CLR. SEALER / SOLID HW-5 AT WEN'S 5 1 ; COOLER I ,` \ __-- � . : , „-. .-J, PROVIDED BY OWNER alilluu = MINERAL FIBERGLASS BATTS SOUND INSULATION AT EXIST. DOOR „ HW-3 -- INSTALL P��'-�iG,, �_T_� J , % ;; ..--- �� ALL RESTROOM PARTITIONS AND CEILINGS. D4 METAL DOOR 3-0 x7-0 H. METAL METAL PAINTED 1 3/4 HOLLOW - - GC TO PROVIDE DELAYED = '1 ,, / _ ISSUE DATE: TO REMAIN D 5 -10 i/2 9 4 EXIT PANIC W/ALARM :;; I I ; I I I 1 ( ,, /1 , H ARDWARE SCHEDULE ; t I 1 ° I I I : I LINE of SOFFIT 1ST PERMIT APPLICATION 01/09/09 u_,___ i INSTALLED AND FURNISHED BY. G.C.G C. I I I I I I I r `� ' %' I t t 1 1 , 1 1 1 , 1 ';',11/i i'///2/:!/:f�//,"/ri ,'f.// ABOVE /J i •. 2ND :vn:w,v,:rs..v;..,v;...,...,vr.:..,.,.y..:...,�I--- _' _T-_s._WT_Am.1_ 1 —_ ..rw�. I 3RD SET HINGES CLOSERS PUSH/PULL LOCKSET STOPS THRESHOLD ADA SIGNAGE DOOR BELL VIEWER KICKPLATE SILENCERS / OFFSET PIVOTS DORMA KAWNEER THUMBTURN - PEMKO - - - - - >a — I h _ 11 HW-1 TOP, BOTTOM & RTS88 BEE 90' CO-9/CP-II 2005AT l I N 4TH •3.0 10'-9" 3'49"9" '1'�-0 /4" 1V-3" 3.-3.. 5TH INTERMEDIATE NHO 626 #14 I OFFSET PIVOTS DORMA KAWNEER - TRIMCO - - - - - - 2'_ " 2'_0" ; 1'_/ / I HW-2 TOP, BOTTOM & RTS88 BEE 90' GO-9 CP-II ��� 2 1 2 - ` _ — J 6TH / 1215CKU !____-0______ j INTERMEDIATE NHO 626 #14 - �� / ; -- _ SELECT PRODUCTS DORMA DELAYED EXIT ALARM LOCK - PEMKO - - PEEK-0 TRIMCO - `� - HW-3 LIMITED TS93-5 PT PANIC BAR SIRENLOCK 710 2005AT #595 K0038 35"x10" Q I A� IX \ /7/ II • ' r L J 1• 2 SL11 689 DELAYED EXIT Er . r \ j�; .:. .. ,, . , . . . ., ..-_. 630 r LLM f� j i 2 <> STANLEY DORMA - MARKS USA TRIMCO - SBH, BLUE - - TRIMCO „ „ IVES 'n ' 1/ - 4,, '7 (; r�' •3.0 DRAWN BY: SAR HW-4 FBB179 4-1/2x4 TS93-5 PT 195 L / 1215CKU SB445, SBH12M K003 =� -600 689 US 32-S 1 SB443 SBH 12W 8 35 x 1 Q SR64 GRAY + _ D= � ( _ -I 630 (BOTH SIDES) _ -- STANLEY DORMA TRIMCO - TRIMCO - SBH, BLUE - - TRIMCO IVES ! 1 I-" = 1 I HW-5 FBB179 4-1/2x4 TS93-5 PT 7141, 630 1215CKU SB445, SBH12M K0038 35"x10" SR64 GRAY = =� ilk iI = /7/\ DASHLINE INDICATES 600 689 7001, 630 SB443, SBH 12W 630 (BOTH SIDES) 4 ` ;' I1''M11 _ )ii SOFFIT ABOVE F PANDA PROJECT#: S4-09-D2116 - _ 1 - A-�, - ,� // LINE OF TRAY _ ARCH PROJECT#: 0821 1. ALL DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL, KNOWLEDGE OR EFFORT IN ACCORDANCE WITH LOCALLY ADOPTED = f/ !��r SLIDE ABOVE CODES. AT STOREFRONT DOORS WITH KEYED LOCK G.C. IS TO PROVIDE A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THESE DOOR TO �' N U ; _ REMAIN UNLOCKED DURING BUSINESS HOURS." _ 407! < EXIST. ALUM. 2. HW-4 IS USED ONLY ON PROJECTS THAT HAVE SINGLE OCCUPANCY TOILET ROOMS. * +I i R I I : ► STOREFRONT S. INSTALL OCCUPIED UNOCCUPIED HARDWARE. �,.:, ,\ ,;, I /// , 1 . -,. :. - i `` ; t < EXIST, AUJNINCx WALL PANEL SCHEDULE S3-A10-WPSO1 02/14/07 �` A2.2�� FLANGE CONDUIT ARCHITECT: <, *kJ I SEE K-1.0 = REMOVE (E) MTL. `- — - A22 ROOF REPLACE imAiih NO MANUFACTURER DESCRIPTION MFG# COLOR FINISH REMARK EXHAUST 0 , UJ/ FABRIC PRE-FABRICATED PER R. P G wP1) KIMLITE / LASCO THICKNESS: .090 LBCS.14 #636 (LIGHT GRAY), SM/SM TEL 800.820.3235 (KATRINA THOMAS) O HOOD A•;�r1/Er// I TRAYSLIDE COUNTER 9/A3.0 / ( ) o E� �! = PROVIDED BY OWNED' •W2 `? WP2) - S.S. PANEL (22 GA) - BRUSHED FINISH . 103 r.. 101 ; `,' INSTALLED BY(WP3) S.S. PANEL (24 GA) - RIBBON FINISH FURNISHED BY OWNER, INSTALLED BY G.C. KITCHEN ,y 1 r en REITER DESIGN GROUP kw.,:_ Y-1---,11, t 3'-10" , SERVICE ! �; AR H1TE T INC.wP4) FORMICA CUSTOM PLASTIC LAM. - CHINA RED (BEECH WOOD PATTERN) FURNISHED BY OWNER, INSTALLED BY G.C. 'liffilirM' , ,� AREA ' - - C C S,• ��.�•�.�•—J...... L 7965 SW CIRRUS DRIVE ,7 e r r --J , �SPECIAL S SCHEDULE S3-A 10-SSSO 1 02/14/07 '{ 102 a``. O A2.I I .; • BEAVERTON,OREGON 97008 ry ,�. i _ h / (503)574-3036 FAX(503)574-2916 MANAGER NO MANUFACTURER PRODUCT MFG# STAIN/COLOR FINISH REMARK - 1 A � / • RE A K di_ STATION , i �-- �� A2.1 A2.0 I. (GR-90) --- GRANITE (SLAB) .--- MADURA GOLD POLISHED FURNISHED BY PANDA, INSTALLED BY G.C. �4 -- , ',t, --r�~ - '..- EXIST. STOREFRONT-- Ali .u ,�i A22 L L � yg DOOR RELOCATED. 'n (BY LANDLORD) STAMP: A,V-11) ilke (GR-91) --- GRANITE (SLAB) --- CASHIMIA GOLD POLISHED FURNISHED BY PANDA, INSTALLED BY G.C. _���� I.1 .. . ...... •A •: GEORGE T. ROBISON._..s. ... . '. /-.,:,%.,-;;/,./klimmusgr., SMII 4,-..) w4 - - ,�- WA LL SCHEDULE S3 A10-WSO1 03/18/02 NO. DESCRIPTION 'j'_-j+� 100 -;-.-- -: • PORT NQ O EGON f / DINING ROOM - ` • ,- 1' Z 2s2a p-. ::_, wl EXISTING EXTERIOR WALL FLOOR FINISH PLAN •SEE SNT_ A-I2 4 EXISTING STORE FRONT GLAZING W - OF 5 '. L. - w3 6" MTL. STUD WALL W/ 5/8" GYP. BD. BOTH SIDES (SEE A-2 FOR HEIGHT, FINISH, & DETAIL) z w4 3 5/8" MTL. STUD WALL W/ 5/8" GYP. BD. BOTH SIDES (SEE A-2 FOR HEIGHT, FINISH, & DETAIL) W2 .- 0 W1 -. ; a � •. , --.I_ - e EXIST. 6" MIL. STUD WALL. PROVIDE W/ 5/8" TYPE "X" GYP. BD. PANDA SIDE (G.C. TO INSTALL VAPOR BARRIER ON PANDA SIDE OF WALL) `;• `TI 1 n ._• 7__ w6 3 5/8" MTL. STUD LOWER WALL W/ 5/8" GYP. BD. BOTH SIDES (SEE A-2 FOR HEIGHT, FINISH, & DETAIL) c • -- PANDA EXPRESS INTERIOR PAINT SCHEDULE A1O-IPSO6 08/22/07 ° TIGARD TOWN SQUARE NO MANUFACTURER MFG# COLOR FINISH D1 � �' < EXIST. AWNING REMARK _� C> L REMOVE (E) M1 C] L L •(P-60 ) BENJAMIN MOORE 2132-10 BLACK SATIN FINISH RESTROOM DOOR FRAMES L C' �� �� �� ROOF REPLACE C> 2 -5 -0 2 -5 / W/ FABRIC PER - - 1 6230 PACIFIC HW (P-9A) BENJAMIN MOORE OC-30 GRAY MIST (WHITE) EGGSHELL, LATEX RESTROOM CEILING > 'I' ' 9/A3.0 C Y. SUITE 100 C> TIGARD, OREGON (P-9As) BENJAMIN MOORE OC-30 GRAY MIST (WHITE) SEMI-GLOSS KITCHEN CEIILNG, WALLS __ ____.__7>-_—_ ______ __ ___ _�__. _ __ - _ _N.>________ (P-98 ) BENJAMIN MOORE 2087-10 NEON RED (RED) EGGSHELL, LATEX DRINKS ROUND SOFFIT, SERVING LOWER SOFFIT \> (P-9C) DUNN EDWARDS DE-980-U2 SUNBURST (ORANGE) EGGSHELL, LATEX SOFFIT, & PROJECTION EDGE Q SERVICE LINE C • NEW DOORS IN _ (P-9D) BENJAMIN MOORE 2018-40 NACHO CHEESE (YELLOW) EGGSHELL, LATEX MENU BOARD WALL, UPPER SOFFIT WALL EXIST STOREFRONT C> (P-9E ) SHERWIN WILLIAMS SW6370 SAUCY GOLD EGGSHELL, LATEX DINING AREA, PERMETER WALLS Q (BY LAORD) Q L SHENANDOAH TAUPE C] (P-67 ) BENJAMIN MOORE AC-36 (WARM GRAY) EGGSHELL LATEX REAR DOOR AND FRAME (-- ({) . TILE SCHEDULE I SEE SHEET A-1.2 GLAZED CERAMIC TILE ( SEE SHEET A-1.2 FLOOR PLAN AND FINISH SCHEDULE QUARRY TILE ( SEE SHEET A-1.2 ) FLOOR PLAN AND FINISH SCHEDULE ri) . ... . . ..._ ... .... . ,.. , . ... : ... _ ......._ , • . • • I .'. • • • Al,. •. • .:r..., a: • ._,„ - - - - LIGHTING FIXTURE SCHEDULE S3-A11 03/18/02 vITEM SYMBOL DESCRIPTION QTY. MFR. &CAT.NO. LAMPS X WATTS REMARK - - Str KITCHEN LIGHTING . \\ 44- oir CP T-BAR CEILING RECESS MOUNTED • e • --- FLUORESCENT LIGHTING FIXTURE, 2'x4', LIGHTOLIER T8 KITCHEN CEILING LIGHTS. L1 ® L1 120V WITH ONE ELECTRONIC BALLASTS AND 8 FIXTURE: D830 FURNISHED BY 0 Q 148 T-8 LAMPS. CLEAR ACRYLIC PRISMATIC XP2GVA332-UNV-SO 3x32W OWNER Q LENS. BAKED-ON WHITE ENAMEL FINISH. ,A �0 T-BAR CEILING RECESS MOUNTED MEN'S ROOM CEILING 4 . ' T8 KITCHEN CEILING LIGHTS. +1'-10" AFF. T C H I N '5 L1A FLUORESCENT LIGHTING FIXTURE, 2x4, LIGHTOLIER m 12OV WITH ONE ELECTRONIC BALLASTS AND FIXTURE: D830 FURNISHED BY 148 L1A 2 3xU32W OWNER P-79 C3 T-8 LAMPS. CLEAR ACRYLIC PRISMATIC XP2GVA3321200-12043 LENS. BAKED-ON WHITE ENAMEL FINISH. —1 I- � PANDA EXPRESS INC. ® EMERGENCY LIGHT, DUAL HEAD LIGHTOLIER 2X12 WATT LAMPS SUPPLIED W/FIXTURE U WITH BATTERY PACK, 120V, WHITE 3 E1-25NH-12W 1683 Walnut Grove Ave. w L3 COLOR HALOGEN FURNISHED BY OWNER Rosemead, California 91770 UNIVERSAL MOUNT EXIT SIGN, LIGHTOLIER FIXTURE SUPPLIED FURNISHED BY Telephone: 626.799.9898 L4 (5i0 LED LIGHTED, 120V WITH BATTERY PACK, 2 FIXTURE: LUNW2G (DBL. FACE) LED LIGHTING OWNER 20 L4 i Facsimile: 626.372.8288 2 FACE, GREEN LEI I ER FIXTURE: LUNW2G (DBL. FACE) 1 r 1 -J - ^� L6A {-,---+ HOOD LIGHT, INCANDESCENT, 120V FURNISHED & INSTALLED SYLVANIA CF34EL ELECTRICAL CONTRACTOR 1 - _ --`,--I',-:::',.---.:-: 10 4 d L4 L3 .,; 30 BY EQUIPMENT SUPPLYER TWIST 3000 K LAMP TO DO THE WIRING ,:'} WALK-IN COOLER FLUORESCENT LIGHT, FURNISHED BY : -'.: '. -- �:< _ L6B _____��; 2 FURNISHED & INSTALLED T8 D830 - 32 FIXTURE 8'W x 4'L OWNER All ideas, designs, arrangement and plans indicated L6B BY EQUIPMENT SUPPLYER 2x32W '' J or represented by this drawing are the property of c', Panda Express Inc. and were created for use on _ this specific project. None of these ideas, designs, DINING AND BATHROOM LIGHTING j J - ! ' ' , arrangements or plans may be used by or disclosed to any person, firm, or corporation without the :-.<' written permission of Panda Express Inc. WALL MOUNTED LIGHTOLIER SYLVANIA DULUX CENTER OVER MIRRORS :- ::.--;,--:,--..'.-...:•.:•-..,7.:: ' �':' ",.'- L71 L71 FLUORESCENT ALL MOUNTEt FIXTURE 2 FT40D/830RS IN BOTH TOILET ROOMS . 30 11 11 CENTER ABOVE MIRROR IN BOTH RESTROOMS ALTER QVW8SPFOS2FT-120-BR (2 PER FIXTURE) \r- ( ) FURNISHED BY OWNER 0 O O U - ' r L72 L72 CEILING MOUNTED LIGHT, FLUORESCENT LIGHTOLIER: ALTER WINDOWS WALL(2)SYLVANlA 18W TRIPLE FURNISHED BY • REVISIONS: 3 TUBE DULUX QUAD BASE OWNER KITGNEN CEILING r 3Q 120V, 13" SQ. WHITE FIXTURE: QVW1 SPASQ2QT120F4 CF-18DT/E IN 830 +10'-0" AFF. C2 i "�: A A i: .' WOMEN'S ROOM CEILING LIGHTOLIER SYLVANIA 37 W ^•, `` ..,. ,..... : . • FREE STANDING DINING LIGHTING AK 0 17 22GR6WH AND MP MONO MR16 ACCENT LIGHTING @ END CAPS I �:y TS' ,; � : `, . ;: ; '' _•ALCYON GLASS RING MR16 TRACK HEAD )`:. ® L73 POINT POWER FEED FURNISHED BY OWNER0 3 =`#.: }:; +1'-10" AFF. (P-9As) 1 C3 , LIGHTOLIER: LYTECASTER SYLVANIA 37 W IN SOFFIT @ SODA LINE _ 'L 2- " `= ® O DOWNLIGHT, RECESSED IN GYP. BD. SOFFIT 14 2004LV W/2008 MR16 & SERVING LINE = , °.' ";l : : GYP. BD. OVER METAL STUD A 7, L74 FURNISHED BY OWNER L6B 0 , '�.'� _ -:: : BOTTOM OF SOFFIT e 10'-6" AFF. BRUSHED SPECULAR CLEAR ��`` � ��� SHORTEN CHORD IN FIELD _. ._. 5.5. ENCLOSURE FROM TOP OF _ 0 :,::::V.,.,.;1-'1i.,.--iii.:::_;,:-.4,--,-,::--,:--E.=$.4,.-----....r:-:-:::,.- --.-:-.:--:: (P-9B) C3 SEAGULL LIGHTING SEAGULL 97102 - =`��f�C'3�:�'`'�-,���:- t '::.-:' :--� °--' :�,-� , L76 �Q _ :: DECOR LIGHT FOR CHINESE LANTERNS 10 6905XBLE-962 AND MP INSTALL W/O GLASS SHADE WALK-IN COOLER TO CEILNG BY ';';: :` >:. ' :. ,: '(2).___ -� 13 L76 13W BI PIN BASE G.C. FABRICATION DIMS. OF = }::-'=. `,;:.. fi . . ' , L73 MONO POINT POWER FEED FURNISHED BY OWNER i.: ENCLOSURE SHALL BE VERIFIED AND MATCH COOLER 1M. r. ISSUE DATE: LIGHTOLIER: LYTECASTER SYLVANIA 15W CFL D LER D ,t :,E24•..,,.. :-1.- 74: .,=-:M L77 0 I 27 1002 P 1 W 1005 END CAP ONLY ;a�` r.` -"': DOWNLIGHT IN CEILING TILE (END CAPS ONLY) 3000K f O O •' L�7 ..," 'µ --1„,`` -� - 1ST PERMIT APPLICATION 01/09/09 18 L17A ( } / DINING LIGHTING _ _ � '� :- � ,rk I�•-. BAFFLE FURNISHED BY OWNER <, = .-3'=. 'va, :.'2'; 2ND NO CEILING WORK ABOVE 0 Y 'I _ ,/0 L3 3RD• 4 JUNG TRAC 12/25 SERIES 25 WATTS/LF WALK-IN BOX TYP.- r - ® 4TH _ I TS SINGLE CIRCUIT LOW VOLTAGE TRACK, WHITE 17 WITH END FEED CONNECTOR FURNISHED BY OWNER L17A AND REMOTE TRANSFORMER II 5TH A3.0 0 6TH MP 0 LIGHTOLIER RECTANGULAR MONOPOINT FOR 14 LIGHTOLIER 6170 POWER SUPPLY FOR L73 C-cYP. SD. OVER METAL STUD _ WHERE NOTED BOTTOM OF SOFFIT 6'48" AFF. �,_ ,,� i--- i. L17A MP MOUNTIGN TO OCTAGONAL OR ROUND J-BOXES t1 f11 f - Ll7a FURNISHED BY OWNER (P-9D) C3 I L6A 1 I -'� `` `- 1 / i-L74 .^ L17A KITCHEN EQUIPMENT LIGHT FIXTURE / • .._-;. PROVIDE BY I L6A I J '-' =,_..I.- _I DRAWN BY: SAR WIRING BY ELECTRICAN, � :-.<,�.---.: �,. MANUF. AND INSTALLED BY G.C. TYP. 1 • •;-:' '-'' .. ..-' L17A T18(2') 1 I 4 - :.�:. L73 I 1J L74•:= ! .. . 0 il • 0 - ., . .1 / ,t CEILING SCHEDULE S3-A11-CS01 12/01/00 ONE-HR DUCT WRAP FOR GREASE _� 11 / L17A HOOD EXHAUST DUCT, SEE DETAIL "' -_ - MP PANDA PROJECT#: S4-09-D2116 NO MANUFACTURER DESCRIPTION MATERIAL FINISH M3_ID / 1 ' ' L73 o / _ �: M3 2'-6" ,-- ARCH PROJECT#: 0821 2 X 2 SUSPENDED T-BAR GRID ANGLED TEGULAR CIRRUS #584 WHITE WITH WHITE TRACK S.S. ENCLOSURE FROM TOP OF Out t y L17A I Cl ARMSTRONG CEILING SYSTEM 1 t / `:'t` _- EXHAUST HOOD TO CEILING BY GC. I 1 '- 2 X 4 SUSPENDED T-BAR GRID 'VINYL ROCK VINYL - CLAD SMOOTH & WASHABLE - WHITE L6A 1 t l 'Y-`_ :, ;,: :, C2 USG KITCHEN CEILING t 1 1;7� '': r CEILING SYSTEM GYP. BD. PANELS + p 4 / -r ,, L17A 10-0 AFF. C2 ---- - _ ;. •L t �-. C3 MONOLITHIC CEILING 5/8" GYP. BD. SMOOTH PAINT - WHITE & WASHABLE ti L6A♦1 v I / < < - - f- _ =�i . ", ARCHITECT: GOLD BOND ON METAL FRAMING 11 • 1 J © ___ . _ ♦0 1 I `Y' MP--t- EXPRESS A3m 1 '� F--.; L17A 1 / .O. 1f' d0 ,;, INSTALLED BY G.G.GENERAL CEILING PLAN NOTES J / EXHAUST HOOD SEE 1 : .'= t� 7-. ---- -S3-A11-GCNO1 12 Oi 00 / .t L73 »: ,.L6A t °. ;: ' `�,, P 1.) LOUVERS, 1 J .:.';:;`.:.,_ := ;`.,, �� L17A L17A AND PANEL FRONTS SHALL BE SPRAY 6.) LOCATE ALL LIGHTS AND CEILING REGISTERS SYMMETRIC- _ 1 J .:: -`:-;.-.-.- - . - .,. : PAINTED TO MATCH ADJACENT SURFACES INCLUDING ALLY CENTERED OVER DOORS WINDOWS OR BAYS OF ONE-HR. DUCT WRAP FOR GREASE 1 , t J / -:,•,••• -`7: :-..- -,1? ::.>-w" � V;, ' - CONTINUOUS SINGLE N I L6A 'ti -::. :: :: : .; :E'_Cy. - = BETTER DESIGN GR.C)VP FACTORY FINISHED ITEMS. NO BRUSH PAINTING OF CEILING DESIGN AS INDICATED. HOOD EXHAUST DUCT, SEE DETAIL i `•r A p / ::?;;. :`,; ::'; -':'. `,._r , _ p - SOFFIT,SEE RED DETAIL ARCHITECTS, INC. THESE ITEMS WILL BE PERMITTED 7.) LAYOUT FOR DINING ROOM ACOUSTICAL TILE SHALL M3.0 x -• 2.) ALL EXPOSED GYPSUM BOARD SHALL BE SEALED WITH COMMENCE AT CENTER POINT OF CEILING AREA. --•i +; - — 18/A-3.0 :. .;... . `.;�..,.. .. MP 7965 SW CIRRUS DRIVE ONE COAT OF SEALER AND FOLLOWED BY TWO COATS 8.) FOR ALL REGISTERS AND DIFFUSERS SEE M DRAWING. SERVICE AREA L6A `.'=`":: :A. .': '-:°L0q.;.:.3. �MP L73 $EA 965 SW ,OREGON 97008 PER PAINT FINISH WITH SMOOTH FINISH. 9. FOR ALL ELECTRICAL LIGHTING FIXTURES SEE E at 10'-0" AFF. �•� i • `.:' .'�.-- - 3.) FOR DETAILS NOT CALLED PUT ON REFLECTED CEILING DRAWINGS. P 9As t 1 ' - ;•' �; L17A L73 L17A (503) 574-3036 FAX(503) 574-2916 PLAN SEE INTERIOR ROOM ELEVATIONS. 10. CONTRACTOR TO PROVIDE ALL FLUORESCENT TUBE LAMPS ( - ) C3 J 1 4.) REFER TO SECTIONS AND DETAILS FOR VERIFICATIONS (USE WARM WHITE ONLY) 11 L6A 1/ _`,., 3 ,- = `:=+:-:,` .--0. '<:� OF ALL CEILING HEIGHTS. - 5.) CEILING HEIGHTS SHOWN ARE FROM FINISHED CEILING LI_ __ ____ �,, t / SURFACE TO FINISH CONCRETE FLOOR I- , ..: - -' -" 0 o. 0 STAMP: 0-1) Ake• : :. '._ `:L7,4'.:'. ' Li 7A L17A L17 0 :L7 ' :;:✓: 21-P" 2 - _ - 1,.,_ DINING ROOM CEILING (' NOTE. ,.V,'..A-4.:.� <:'-,. '-'��-��.`:.:: . ;: , ��� 2 2,� L, �„ GEORGE T. ROBISON�' ROOF STRUCTURE- PROVIDE BLK'G AT _ 2 rr--. - �� - 12'-0" AFF. C1 104 y BOT. OF TRUSSES WHEN CONDUIT -'�- PROVIDE 4 VERT1Cl WIRES _ C` --- - - (ATTACHED TO MAT' RUNNERS) - .� ' -- + FALLS IN BETWEEN - J .. 117A ' , ` ' 'RUN WE THRU CENTER WITN 3 SPACED 76` L76' L7E' ` ' Li fi' PORT EGON 3/4CONDCOMPRSION STRUCT ' FIXTUR'. 4 FEET ON CENTER �- `- ' `� -- --- `' --,) �-• L17A t 2520 O (PLUMB WITHIN 1 !N fi) .� PRESSURE FIT BETWEEN ROOF TO ROOF STRUCT. WITH �,-g„ - -- , STRUCT. & CEILING MAIN RUNNER EYE LAG SCREW L73 i , \ ; `, ' J 1� O 0‘)'‘ LATERAL BRACING (4) 12 GAGE 9 9 9 - ®P OF AT 12 -0 O.C. EA. WAY WITH Q Q �, , WRAP WIRE THRU TS(4) L17A L76� L76 • L7€' ` L76' ' L�6 FIRST POINT WITHIN 6'-0" OF _ - _ „ PREDRILLED SLOTS IN LJ LIGHT FIXTURES WEIGHTING LESS THAN 2,_6.i 2 -6 PERIMETER WALLS. - / i RUNNERS & AROUND 10 LBS ONE 12 GAGE HANGER WIRE '� OP T18(2')-� START CEILING HERE BOTTOM OF CONDUIT FROM FIXTURE TO STRUCTURE ABOVE _ L17A L17A L17A L73 PERIMETER WIRE AT LATERAL FORCE BRACING: LIGHT FIXTURES WEIGHTING MORE THA'U EA. TERMINATION -. 4-12 GA. SPRAY WIRES 10 LBS AND LESS THAN 56 LBS 11 L7832) T18(2') Q T18(2') � POINT _-____ _ (AT 200 LB. DESIGN , j TWO 12 GAGE HANGER WIRES Q L73 t 3 PANDA EXPRESS / » L05TO STRUCTURE ABOVE — ® 8 ,8 MAX. L17A TIGARD TOWN SQUARE 4, . ■\ 45 S -� L17A l n l L17A L17A L4 �) J L17A•, I 1 1 •P (1----I , ___I I n...,............_, \ ACOUSTICAL CEILING \ 2'-��� 16230 PACIFIC HWY. SUITE 100 CROSS RUNNER TIGARD, OREGON BOARD \ AT 2 -0 O.C. il -/ /--- N LECORATIVE LIATTERN, PROVIDED ! -- 2 MIN. WALL MOLDING \-------- MAIN RUNNER ® 4 o.c. LIG „T FIXTURE SEE E DWGS FOR FACE OF WALL ATTACH RUNNER TO WALL SPECS. PROVIDE SCREWS OR CLIPS 31' OWNER, INSTALLED BY G.C. MOLDING, OR USE & FASTEN FIXT. TO T-BAR SPREADER BAR. _1 I Efl--) PROVIDE "HEAVY-DM” CEILING SYSTEM AS DEFINED BY ASTM C 635-00 A..... 1 • i . NO SCALE NO SCALE REFLECTED CEILING PLAN T-BAR CEILING DETAIL LIGHT FIXTURE DETAIL REFLECTED SCALE: 1/4" = 1'-O" CEILING PLAN PREPARATORY WORK Tile installation must be fully cured. with joints clean • . f TiLE SCHEDULE Al2 from excess mortar and constructiordebris. With a slightly dampened sponge. •Tsob �2�o1�os ._ ... �� _ • • wipe face of tile to remove did or dust. Do not allow standing water in the joints. _ NO MANUFACTURER DESCRIPTION SERIES MFG# COLOR FINISH JOINT GROUT REMARK mixing: See Manufacturer's specification for details. (r_19_9) TBD 6"X24" WOOD - MIX BROWN - B.JT. - DINING ROOM FLOOR TYPICAL FLOOR TILE Thin set in latex modified Portland cement mortar E bond coat with latex modified Portland cement grout. (T 91) TBD 4 X24 WOOD - MIX BROWN - B.JT. - DINING ROOM FLOOR OA, - - W�� FLOOR TILE COOKLINE Thin set in chemical resistant epoxy grout with (-92) TBD 6"X24" WOOD - ACCENT - B.JT. - DINING ROOM FLOOR chemical resistant epoxy grout in color as indicated on color schedule. 0.-93) TBD COVE BASE - - - - - SERVICE LINE LOW WALL&DRINK STATION BASE TILE GROUT SEALER Auqa Mix Sealers's Choice 15 Gold j TBD penetrating sealer or approved equal. a. ! (T 94) COVE BASE - - - - - RESTROOM COVE BASE k 0 0 \ (1) , (T-95R) EURO WEST F-714.309.9551 8"X13" TEXTILE - RED - 3/16" TBD ACCENT TILE ON RESTROOM WALL GROUT APPLICATION See Manufacturer's specification for details. O 9sw} 8"X13" .'„ •EURO WEST F-714.309.9551 GROUT PROTECTION Light traffic can be allowed in 18 hours at 75 degree F, GI 4 TEXTILE - WHITE - 3/16" TBD RESTROOM WALL -` WEST F-714.309.9551 3/16" normal traffic in 24 hours and heavy traffic in 72 hours. G O (./...95,0 EURO 8"X 13" TEXTILE - YELLOW - TBD SERVICE AREA WALL k RICHFIELD TILE CO. 6"x24" " FOR WALL BASE THAT RECEIVE BLACK TILE WAINSCOT FLOOR MUST BE PROTECTED WHEN MOVING HEAVY EQUIPMENT. !' 0-96) T-626.810.1819 X139 PORCELAIN _ BLACK POLISH 3/16 G-64 OWNER PROVIDED, G.C.TO INSTALL �T Cjv (1-97) TBD 12"x24" _ RED _ 3/16" TBD LOW WLL BEHIND DRINK STATION G.C. TO SEAL THE GROUT THE ENTIRE FLOOR INCLUDING THE DiNING AND KITCHEN AREAS. C�--! t m' 0-98} TBD 12"X24" - BLACK _ 3/1 6" TBD DINNING WAINSCOT oar SOLIDS EPDXY GROUT 0-71} SPEC CERAMICS T-714.399-1720 6"x6» SPEC COPPER - COPPER DECORATIVE TILE FOR EXTERIOR TOWER 1 PANDA EXPRESS INC. F-714.808.1041 QT QI (QT) DAL TILE 6"X6" QUARRY Q40 RED BLAZE PLAIN 3/16" G-63 KiTCHEN,SERVICE FLOOR TOP OF 1 TOP OF 1683 Walnut Grove Ave. (QT1) DAL TILE 6"X6" QUARRY Q40 RED BLAZE ABRASIVE 3/16" G-63 KITCHEN,SERVICE FLOOR CONC. PAD CONC. PAD Rosemead, California < (T-9o) 91770 (QT2) DAL TILE 6"X6" COVE EIASE Q3565 RED BLAZE PLAIN 3/16" G-63 KITCHEN,SERViCE BASE _ GROUT 1I '� ; ; ; Telephone: 626.799.9898 --- - r, ! i -. -. _ _ Facsimile: 626.372.8288 (G-6 MAPEI T-714.399.1720 LATEX MODIFIED GROUT. SANDED RESTROOM WALL , - -/. F-714.808.1041 39 IVORY / / I yi,--i J-T-714.399.1041 LATEX MODIFIED GROUT. SANDED l ) , , , , ,; ( . :/X// ,r', /,'- ,`i'„,,,,,_/ /,,,-/ ,,,, r' / - - G 6 MAPEi LA E MOD F ED G U 11 SAHARA BEIGE S DED DINING ROOM FLOOR, RESTROOM FLOOR. 3/16» JOINTS (T-91 J (QT1 J /`/,'r i � i r' ' ' ' C F-714.808.1041 _.1_t- ?-/�; -4 ;'tom -' / , ; /_,%_�` 14! ,7- �_ , - _ -i ( lf:� r 4� j !rl •' r"r �{ -,iY � f�7,` / ,cif .1/ KITCHEN, SERVICE AREA FLOOR / / / /> /,, '/ �_Y a , '/' '',- -`"- , G-b MAPEI T-714.399.1720 LATEX MODIFIED GROUT. 16 MALT SANDED ; { ! : //' i X,' ,;,, <, r,fi /' f t,i • ,'„ , ;r,, ?., All ideas, designs, arrangement and plans indicated ( 100% SOLIDS EPDXY GROUT © COOKLINE AREA ± I __j- ' I ! / 1 I ' ; ; } ✓%:,'/,4,4 7 . f' /, ' ' `r - ” — — F-714.808.1041 I 1 �, f / or represented by this drawing ore the property of y ; -�� , 1--- --! - +—� I. ,, e ; v , ,„ , •7,�Y/` 4,/,/t ;/,{/ z, ! —i ;�; ±;; - - Panda Express Inc. and were created for use on 111111111 T-714.399.1720 10 BLACK l X / /,/ / / {'` / X i/ ,;!fr , ,'x, "" 't __ _ _ this specif,c project. None of these ideas, designs, (G-b� MAPEI LATEX MODIFIED GROUT. SANDED DINING ROOM WALL BASE TILE, T-69 I i , / /1,, rt I ,$/ ,(„/, 1� // j �/ // ;_�: F-714.808.1041 1-1--; r f ✓ -r r/r ;fil,, , T` /, , /, ' arrangements or plans may be used by or disclosed I ,�.■r�! '! r--;. �tf// !y-;.,,f/ ,/'/+/' / l. f-- ____,_. .-.4_! �. _ to any person, firm, or corporation without the _ ______ T-92 , I /� ' 'l / - - written permission of Panda Express Inc. ADDITIONAL 5/8" TYPE X GYP. BD., FULL it` - / _ _ LENGTH UNDER HOOD AND UP TO 10'-0" "■■■' I { f I' i• '% // • { '.v ,...,(212,4.../t,../...„,/ f i g, r �_t - _ HIGH ' `� „ --ir ':� ..�/ i / fi*�,1 fy/r/y � /� f ,�,�� �ft' �'"' ,- TWO LAYERS OF 5/8 GREEN BD. .-)..,� l i /`�,',/ < -Fl,r. �,`,>= , r, ,' /2- '- ',�"C;; i!,! ,-, �'''t dd -0;■�■a■■�a ' I _ WOK RANGE rt _ 4 N T F TWO LAYERS i _ T: I/r / /, rr / / ., h;' / � x/., %, 8 HIGH, 0 OP 0 ;-! -,7 ,#• /r ,;/� � i i r ,,/, /' "," "/'''' _ _ I 18 GA. METAL STRAP BACKING, SIZE AND OF 5/8" X 12" CEMENT BD. i % -t ; ; ;� J fir,'u, . , � ; ` � / I 1 _ _ , / ! ippilli R ELEVATION PER DETAIL 2 / A-4.2, / , _t ? > .� r " " __r •-- ' i REVISIONS: c, i ! -{_ i /%'�j1r r`_i _!_IlNllllli� 'O IIIIIIIIII I� 1 1/2" S.S. SCREW FOR SECURING C ( ) ! /',' ``'' L J_!__ -._i___i Lea - - A EQUIPMENT TO WALL WALL FINISH WP3 '1- \ J t - } \`,'\ STUD WALL r _ QT _-t. ;_. i �--L---�--.--- �����>�:,�- ._, - /, SILICONE JOiNT SEALANT / / N\ i i ' ' ± ; - �;' i,.t/' _ ;ter,/,/ / //,. //// , /'//',/,;-//-�,' \ - /L\ /Ng LENGTH OF EXHAUST HOOD /` \ / ! � _ �- % - SS FLASHING BEHIND / - I i-!� ``/ter/� /////4 ,),/,/y! 1 _ -�' s I � I�_. __; ,' Ai- SS WALL PANEL AT TOP / �y I i F � QT1 INSTALL FREEZER ! 1.%f `9',* r r, -•, i-, - , �f; i, � OVER TILE / i , ;/ -1'�-1`='r '/4 /../'% `"%`% ' ! Plo.1111 11111111 - _• ,� `- LATICRETE 9235 WATERPROOF G - ,' _�.r rrrr�r�rrr .rr rrrrrrrrrr rrr „ ;f, , ; - - --_ - r ,/e f 1 1 I ����,�/���� , 1�� �� t�}�+;��� `� +�r MEMBRANE, 8 UP ON WALL I . 20 GA. GALV. PLATE BETWEEN 1 ' i I ' �-'1. j t i `L ii, / , , i`! ft -i_ ,.-% �.i•.�.�1 1 _ �>1 �+1�����/���►� .��♦ ♦���������J ����� & 24" ON FLOOR BETWEEN I /'f ' ' 4 i i -r --,1 }- ' . .,..:-- ' I--; / �'' .: /k- k L / ,. mot s ,.��■i MTL STUD AND CEMENT BD. ■, _ _-- ; 4_ Z • CEMENT BD. & QUARRY TILE . ., aura•,*.�• ..�•.a•I *.• o - � - J % �/ i `<- ,�% I ; '' I , 8 UP & 1.5 ON FLOOR. & _ ,. .�� vv.ri - - �.y.f r. .�; t r, , _ /-- _ / 1» OVERLAP ON GALV. PLATE �. 'i ' _ / 4 . 1 0 '/,,,/1/72,1;/'/:, I'. ,177, NOT E UND i' QUARRY TILE BASE ,,//,/ .,,_ I - l -I -T ,; ,rt, n , - - - E STUD WOOD OR METAL) ® 16" O.C. QT 0 I-i i - I 1 f/- / %. ,/ /. �<, . w DRf STATIC' : ISSUE DATE: - ili, ) SLOPE FOR POSITIVE DRAINAGE /( .., O - _ - I . INSULATION IF REQUIRED 1/4" IN 24" TYP. __ _____1) /// � 1 i /;, ;r,: �� l - ,• ;T, .- -1'` _..1:, j-_I- L_- j_ - �/ _ _ » » --- - �` _-, • , - _ _ _ PERMIT APPLICATION 01/09/09 —5/8 TYPE X GYP. BD. OVER STUDS �� QT1 - sx/�f� ,� /�`,�"'//l F�= f # 1illI -_ j _ _At iriffiff tAtAtAtAVA! �11 ! i—_, // L ' — /r• /--/,/' I''1 /r .,I { > ! / — a.-_ - _ _ i 1 ��I� i�m�®lniI® r;:U I 1 r- ;_;_ '�►� _ 3RD 44 DRY PAD FOR SEALANT, GE SILPRUF ,412 .6I - 1 1 t ; t ,I , T ; 2 1 7 ;( -T ; i 7 "�' - - - - - 4TH i f ' 1_: _ _ _ _ _ — SLOPE DRAINAGE SCS 2000 _ i I ! t -_f _ - Ir+e& 's.'. '1,• isr; '�i•p`_n -- ._ I _ - 6 I'r �' �' ." '+ _ - r r f' r , i.r � l ©, r-- r 6TH t �' /',- f_l , fr • y.z.,/-y -(- 'WATER PROOFING REQ. QTi _GYP, BD. BEHIND COOKLINE 4 8WALL BASE @ COOKLINE / - ' :w:� _ :�:�NTS SCALE: 3 =1 -O" ,, „ • , `i, , ' 4,�,,/• , ,,„, _ - __ - _ 24 OUT ON FLOOR TYP. 2- 1 ,- _ _ _ _ _ J . . . ... .. .. . .. . . _. .:. .. .. : . NOTE: IL1P w , _ � _T �,',����;� �-- - �- / �/,, DRAWN BY: SAR QT1 �; y / 1 /. �4 , INSTALLER TO PROVIDE A WATER-TIGHT SEAL BETWEEN ----- --- /v_;../. - � - - ii__ii__i_E BOTTOM OF COOLER BOX WALL & QUARRY TI E FLOOR / •il. 'r,{,r _ _D _ _3 !N FONT OF � > � I„ _ I>� � • ;• , �,COOLER ” — - -I / _ _ DUROCK. • / -- i ; ' f , �r - i - - - - - 4- 9-D2116 ____ 1111114111» ` < METAL -' / _ _ _ _ _ PANDA PROJECT#: S 0 8 R. COVED BASE S.S. ' � r� ' � �� • '. `'3/ ( CLEAR ,OUTSIDE, ALUM. INSIDE BY STUD I • ;- - , r i�__....! - _- -- ), SILICONE {_�__� i i_�_ � %�,�.;, - .�, � � ARCH PROJECT#: 0821 KfTCHEN EQUIP. CONTRACTOR, LANT GRANITE BASE \ _' � � i�rr I �- - �� ` - _ _ _ _ _INSTALLED BY G.C. SEA / `N Al2 t :__.T ( 1.--_-3_7 j ! L ,X/�rri 'r _ ! _ _ - _ _ikii 041 < \.. -I - - - II I LATICRETE 9235 i MTL STUD SCREW; TOP ,, { --fi- ;- �,,-- _.s. ,4 T AT / T-91 TYP IR / OTTOM c� 16 o.c. QT -. '' —T — —� �r�_=� T91 ARCHITECT: CLEAR WATERPROOF G MEMBRANE, / & B _f ►' �, /, ±SILICONE S.S. RIVET ® 12 8 UP ON WALL & 24 ON i` U1/ EPDXY CsROUT °�' +- 1 • ty ,,,/,_ - �� !:O.C. F WEN CEMENT < ! ?? "0 GALV. PLATE UNDER COOKING " 1 ' / ,i% :,pl y 4" i a - SEALANT CLEAR LOOR, BET E / ETN MTL STUD AND t`%% /` ' ' I`? T /. r RPG NI, BD. & QUARRY TILE / EQUf PMENT �_� 1/ .., _. y '� I I- ' ;!;'4,-t/,• >, L ! % _ fi 1_/ _ t, �,' �� ^, -�,i FLOOR TILE V. PLATE E r' / ��) - - - - SLOPE FOR POSITIVE ` SLOPE FOR POSITIVE � t ;Y/ - ' t -� _ _ - " , DRAINAGE 1 4" IN 24" - ,/7;4,?//1,'. '' REITER DESIGN GROUP DRAINAGE 1/4 IN 24 / / ` n -r ' ,! %i #' - �z°')r�� _ TYP. QT 1 \f T,A1(''/-7-/t1,Y ' / _i._.S. f//1!« '-•.!1 ' fi t l)TYP. II ITYP• / + _ ,� ' - . ALTERNATE tU T-gm T90 ARCHITECTS, [NC. / W/ EPDXY GROUT � /i Al — — \ h I \ 3ro" IN FRONT OF IILJ '`. ' '' / '/ .�/ � �_ 7965 SIN CIRRllS DRIVE j � -', ''-//• :, Y,' ' , k_� BEAVE53n: RR S DRI 97008 r COOKING EQUIPMENT -� - � ,f_ �-- — __ j•7 / / Q N I- -, - .7_-fit %% '_ /t/4_2/1-_ 't i; _ r - /: �',' s - ! _ .._, _., (503)574-3... FAX 05 . , 574-29. • SEALANT, GE 1 li i 1-I`I r ; ' :/�' ',f i/ ' ,;/``7rf/ / i _ _ f• ___ • TILE OVEN"THIN SEA .. SILPRUF SCS _ __ A/ ,,;� ri' , i 4PIiT. SPREAD FOAM BEWTEEN SEALANT, GE / r ' - - - A/ MORTAR 2000 -�' i ' /` , ! �' _ ___ VERIF 4 ADJUST TILE y ?` - _ I_ _- -- QUARRY TILE AND WALK-IN SILPRUF SCS �, di►,+�� i- � - - __- ; G_, ' ; /,) ! /- _ — , ; _ _ INSTALLATION AT WALL PANEL 2000 �� _ �/_ �_- t---�--'- - - / - ,�; ' �-'-'- --�- � �.� ' ---�' TNRE OLDS TO PROVIDE �R�'" %� = r � _ - ; , _„..„; !,/ STAMP: �y I r v / r'= t _ _ LEVETRANSITiONS. (.WALK-IN COOLER BASE ;_!11 . y�T,r=-�- 0 t - - _WALL BASE DINING RCJONI �_ , /_,-, - + - - - - SCALE: 3"=1'-0" " ' ` 1--- i /I r+ , , . I "' " — �'� _ _ _ I " GEORGE. T. ROBISON `C SCALE: 3 =1 -0 �■ 7! t" i ; ' ��"- ■ - .... t i '1(WATER PROOFING ON KITCHEN SIDE ONLY ;//,,',� I _ _ _ I ;� - - o, �, uN l i, uI _ - �PO l 2520 OREGON ,r 1111111111, . Niill 11_ I 5/8'' GREEN BD. 48 - J cEMCO METAL • 1111111111111°11/ 5/8 GREEN BD. 48 HiGf�, / STUDS ICBO # _ — s.f.P4' OF d HIGH, ON TOP OF 5/8" X '� ,/ - 12" CEMENT BD. BY / ocEMEOP OBD5 B8„ DUROCK. /i;; . �� '/ M - _`.. /� STU -_LAR # 22646 E:� =`''- ,� ACCENT TILE\ `' - --ON 0----F/ E _ _ _ PANDA FOEEN / NN - - - CEMENT BD. & / ' Ii _ _ _ _I' < IUlLCREW, SEALANT MTL STUD SCREW, �_ ,, ,, ', ,' ' ,' '' ' _ ,� _ TIGARD TOWN SQUARE CLEAR SILICONE SEALANT /,- TOP & BOTTOM ® TOP & BOTTOM @ 16 �����������. ■■... ,,.��_ ■..■._�_��.�_�_��.��,,,�_�_!_..�( �C GALV. PLATE LATICRETE 9235 Qr 1 1 1 I�:LSI \�.I 4 I S.S. RIVET @ 12" O.C. '� vA BETWEEN MTL STUD WATERPROOF'G MEMBRANE, vA B T GA. GMT STUTE AND BETWEEN L D 3/8" R. ALUM. COVED' / AND CEMENT BD. 8" 8" UP ON WALL & 24" ON CEMENT BD. 8" UP & 1" I I pp BASE BY KITCHEN EQUIP. UP & 1" ON FLOOR. FLOOR, BETWEEN CEMENT ./ 1" V P I VERIFY d ADJUST TIL 1 6230 PACIFIC HWY. SUITE 1 CONTRACTOR, INSTALLED BY BD. & QUARRY TILE ON FLOOR 0 ERLA I �' INSTALLATION AT TIGARD, OREGON G.C. ��, 1" OVERLAP ON QUARRY TfLE BASE ON GALV. PLATE�, GALV.» PLATE » „ LEVELNTORANS TIONS OvlDE QUARRY TILE BAS w , HILTi POWER DRIVEN HILTI POWER DRIVEN I SPREAD FOAM BETWEE ' !• SLOPE FOR POSITIVE PINS CO 24 O.C. MAX.'� PINS © O.C. DRAINAGE 1/4" IN 24" TYP. 'QUARR Y TILE AND 1, _ s,= A r MAX. TYP_ U.N.O. f, i-- -J TYP. U.N.O. I.C.B.O. # _J I I WALK-IN WALL PA ::{ 1 =--�__ _ _ . .. •- '! I.C.B.O. # �290 ..,-.�.. _ TILE OVER THIN TILE OVER THIN SET MORTAR - `' SET MORTAR EF) ' SEALANT, GE DRY PA -FOR SEALANT, GE A IMMO 1 . 2 - SILPRUF SCS 200 SLOPE DRAINAGE SILPRUF SCS 2000 WATER PROOFING REQ. WALL BASE @ WALK-IN BOX WATER PROOFING REQ. FiNISH '8 UP WALL AND STUD WALL 6 8" UP WALL WALL BASE @ KITCHEN FINISH FLOOR PLAN FLOOR PLAN 24" OUT ON FLOOR TYP. SCALE: 3"=1'-0" 24" OUT ON FLOOR TYP. SCALE: 3"=1'-0" SCALE: 1/4" = 1'-0" - - _ - - - - : • • ` 4ir lo . ' •• o + • - - - — _ _ - . . 3/4 ALUMINUM . CEILING MOUNTED ID -- --!---_ -_-------_--,,_ - 3/4 3/4" 1 T 98 TYP. - OFFSET 374 EXIT SIGN, L4 (if)ie ie .11f \ T 98 BUTT JOINT ---- 3/4 ALUMINUM TRIM EXIT - ALIGN TRIMS (P-9E) 1 TILE/TRIM FIELD DETAIL C H I 1•1 0 C .I''''"'":**:-...'6%.1.- ..:.■••••••••!* ::1 4.0 3" = V-0" I I PANDA EXPRESS INC. / „/"/ I ///:// / // // // (P-9E) ///:: 1 683 Walnut Grove Ave. (P-9E) /-/ /// FACE OF GYP. BD. Rosemead, California 91770 'INN" 3/4 QUARTER ROUND . 6 Telephone: 626.799.9898 ALUM. TRIM CAP ///\\\ , 2 0 _J Ci z Facsimile: 626.372.8288 . . / \ I I .. . . . SS T-98 WALL TILE Allilk FULL TILE START LAYOUT ' AIM >,- CJ . . . . ' . ., . , A4.0 HERE / \ A4.0 C5 All ideas, designs, arrangement and plans indicated / //// / /// C6 or represented by this drawing ore the property of Panda Express Inc. and were created for use on - //:// /// / , / /11 \ // _______ __________ .,________ ...., //; this specific project. None of these ideas, designs, 1 1 i \ / I > --1— I arrangements or plans may be used by or disclosed to any person, firm, or corporation without the ' - 2 TILE/TRIM WALL DETAIL 1 I r_.........AIMININO MMINOM-71 written permission of Panda Express Inc. 1 1 40 3" 11-0" N I IT? 7 [ ;\ ,j, , , Il il 1 _-_, - 11/ REVISIONS: . t \-,:•A- \ 1, . ...__ _7 7._ —1 __ T-98 TILE SILL A I , 1, _ , . . 1, Ai NOTE-: , : , . CT -- -- -1;, , . ALL EXPOSED t_DGE: OF WALL TILE i - : , I \ /4/1 1, , ' . MUS I RI-. FiNisl-ILD Jo mAtal 'r- -- -- 1---ii , tik--*--- 3/4 QUARTER ROUND i] ' -,/,/ //%/ -1 :1 11=. -_-_-_-., — : . SURFACE_ FINISH. EA',.-:;E TILL EDGE A 1 I 11-, \ / / ALLowABLE__. I ALUM. CORNER TRIM 1 i I:: : i E--- - -- - ) \ . A ______ __„_______ \ , ll , , , ., 1 \ i-- I I \\,/// I ,\ H . , , . .. ,. ' A i, ., , , I I CANE RAt. DECOR NO1 I..: - T-98 WALL TILE A All WALL DECORATIONS, PRINT LOCAI IONS, ETC. TO I-11- VERIFIED WITH I A PANDA EXPRESS BY (..C. A4D C.C. c.-ThIAI I PROVO} ANY P1 IA (T-98) (T-96) FULL TILE FULL TILE ' RFOUIRLMENIS OF NcoR ii[m EXIST. ALUMINUM 6'-0" EXIST. ALUMINUM EXIST. ALUMINUM , . START LAYOUT START LAYOUT INS[AI I Al ION ONTC) WAI I S (HIDDEN TILE/TRIM SILL DETAIL STOREFRONT SYSTEM / / STOREFRONT SYSTEM STOREFRONT SYSTEM RLOCKING, FTC.) 3 HERE HERE 4.0 3" = ii-a" NEW STOREFRONT 8c DOORS (PROVIDED BY LANDLORD) ISSUE DATE: 1ST PERMIT APPLICATION 01/09/09 SOUTH DINING ELEVATION 2ND SCALE:1/2" = 1 '-0" 0 3RD 4TH 5TH 6TH . . DRAWN BY: SAR . . - . . . . . PANDA PROJECT#: 54-09-D2116 CEILING MOUNTED . PROJECT#: 0821 EXIT SIGN, L4 . . . ARCHITECT: - „ EXIT • (P-9E) (P-9E) k P G REITER DESIGN GROUP ARCH I TECTS, I NC. 7965 SW CIRRUS DRIVE BEAVERTON,OREGON 97008 (503)574-3036 FAX(503) 574-2916 , / / / / ,/ (P-9E) (P-9E) / /2 ///,./ // (P-9E) ///: / ,// //2 i // /, • . . - STAMP: 0Y-.11) ARc — . / . rrO\"... ....,,,nRGE T. ROBISON t* -) GEORGE / c-) 2 FULL TILE FULL TILE FULL TILE 2 . A4D START LAYOUT START LIWOliT START LAYOUT , A40 • HERE /i. HERE HERE / / PORT ND, REGON 4 .._ ///// --/// // /// % 2520 / _________, -------------------------------- \\ / r*IMAM&1111••••■■■■•••■■•■■•■1 . OF .00 ,/,/ I I , . . . . . . . . I I r,-, /----- c,-) 177 \-1 T1 71+ 77 I/, ( . 1 .. . . „, ,/ \i r- I .1/ ___ ____ -- - -- \ I ,I i I PANDA EXPRESS \ / , 1, , „ , ,, ii ,, . 11 I (' -■ .1 I , I ;r ■ I . , „ ., ; : I' I . .t I 1;--- — -- —, . * — 7 I / 1 i--: — ------ -Th 1 h: --1 . . . - . !7- - --- - \ , ,=..- == == 1 1 1 ///( /.//° r . . ,: / i: - ---- 1 . ' . :I I , 1 1 i 1- — TIGARD TOWN SQUARE ,, I .//,/ ,,/!'-_,. : =1 I 1 .- = __, ,)1 fi /.-( , , i, , / i, , . /'/,'=, , '. \ / i , 1 '1 . t_, — -, . i il 1 . J ,, ,. :, \1 II I .1 ii , , i i . , _ , , i ,, ,1 t; ,I , ili , 1 . . // II i \‘\ t 1 ' 1 I .; . , ,, , . . 1 : , \ Ji 1 i ii 7— \I ,i' • ,, * .. . . ,1 ,, , ' " \ 16230 PACIFIC HWY. SUITE 100 TIGARD, OREGON A4.0 . .--- (T-98) 0-96) 0-98) (T-96) (1-98) (1-96) EXIST. ALUMINUM EXISTING DOOR EXIST. ALUMINUM FULL TILE 1O'-4 1/4" STOREFRONT SYSTEM RELOCATED STOREFRONT SYSTEM START LAYOUT / / (PROVIDED BY LANDLORD) HERE NEW STOREFRONT (PROVIDED BY LANDLORD) . .. EAST DINING ELEVATION SCALE:1/2" = 1 '-0" INTERIOR ELEVATION - - -- - - - - . . _ ..... _ - - - : • • ., • • • ''' •.• • • • * 4k:•liP.' .* .,• _„....- • • • :e., *:,1!" :• . '•.- - - - -- - - _- ELEC. OUTLET FOR ICE-MACHINE BY G.C. PVC DRAIN PIPE TO FLOOR SINK BY I WATER INLET PIPE BY MANITOWOC. MANITOWOC TO SEAL GAP MANITOWOC • 0 • THRU THE PRE-DRILLED GRANITE-TOP ELEC. OUTLET, PAINTED COLOR AS LOW WALL TO SAME %.. ................,........... .....,1 4-, CONTINUOUS SINGLE RADIUS GYP. BD. 1/2" COLD WATER OUTLET W/ v. .,... STROKE OF RED NEON SOFFIT BALL VALVE SHUT OFF BY G.C., C H 1 FOR FURTHER EQUIPMENT (T-95Y) 1 2'-O" A.F.F. * PANDA EXPRESS INC. \ /I , . . . , , ' : , , ,, ;,.. ' ; ; , , ! 1 , ! ; , ' , . . : , 1 , : ': B.O. LAY-IN CLG. \ .' i 1 , , i h 1 . • : , , , ,. , . \ ., 1 , . , ' , . i , , . , , 1683 Walnut Grove Ave. \ -7' , 1 : 1 (P-9B) : . , . : . 1 i : ; ; Rosemead, California \ , (P-9B) ; i ; 1 1 i 1 ; ; , ; 1 1 1 ! ,, 91770 . , ,- —/ 11 i 1 ; : . : . . . 1 ! 1 i: 10'-6" A.F F 66„ . . I./ \ .. / I 1 I B.O. SOFFIT Telephone: 626.799.9898 I i T , \ ' 1 Facsimile: 626.372.8288 • /' . _ . _ . •„. /9 -3" A.F.F. 1. . ...._...Cp29c).__ . t_____. . ____ . ___. . t___. • .................4 \ ; I FULL TILE , PANDA / B.O. SOFFIT 7 '- ... _ (P-9E) (1-97) START LAYOUT MURAL ,,,...,,. MENU BOARD ...----- HERE 8'-6" A.F.F. All ideas, designs, arrangement and plans indicated MENU (lie) 1 / . or represented by this drawing are the property of Panda Express Inc. and were created for use on (NOf{AINT --... / B.O. SOFFIT (P-9E) (761:D (.1)-90 (ID-9E) (P60 ) . PRIMER 0NLY SMOOTH FINISH) ..---- >< , ,,, (P-9D) - - , this specific project. None of these ideas. designs, ifI \ ..„---- ,--- --,,, ..,,,.... *II Um 41 I arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. / ,.// 6.' 8" A.F.F. ,., ' . , . -,....._ I , . , , / / \ I \ B.O. SOFFIT -1 1 ., , .1 _ ______ / BRAILLE SIGN ..., .. , „ I I I `, . . ,„ , -,...,,, -- - , . . . . .., ., .. .. ._ . ....,,. . . 2 / KITCHEN BEYOND _--- . : . , 2 \ ' .. ‘, FULL TILE , FULL TILE FULL TILE , -----.„, rri*11=1- L ...,---,_--1,7 , , , ,, REVISIONS: ‘,START LAYOUT ,./li_ 7' / 44.0 START LAYOUT \ , . I I 1 \ ., , A HERE ! „; HERE - _____\ i ;`•;i: \\.;\ / HERE \ \ --... , . ._ ID ' (GR90) 2 I I ., _______ ______ ____________ ___ . ' . 1 I. 1 , , . , . , . ,• , / '----- ' ' :: 0 , ------'- 1 : / 1 I , - A 1 , . ' \ / . ,, .. -,...,, \ • AI 2 i \ I . • . •, , . 0 I 1 i . . _ _ . - ' ' • _ .- • I I I t I , . , 70 1 -to '1 TI_E BEHIND cy , ; ,, I . r. ......... 1- 1 NO COUNTER/ ' . , -4- •. \ i / 1 oo -- - , , . \ ' 1 :..- , . . . . , -4- 1 . ,. , I 1■1 / , , .. . , , PO , I ' - , , , , y L . ISSUE DATE: • KICKPLATE \\ I , I / K1CKPLATE — _ . . . , . . •• I , . , / 'IL 1 / i / , ., (T-916) 2ND , y )1°, PERMIT APPLICATION 01/09/09 1 3'-10 \9/1 6" 3RD TRAY POCKET, SEE SERVICE COUNTER, 5'-9 9/16" CUT 1 " AT (T-98) (T-96) CUT 1 " AT (T-98) (T-96) DETAIL 3/A3.0, 7/A3.0, (T-97) 0-93) SEE 3/A3.0, 4/A3.0 FULL TILE START LAYOUT 1/2" COLD WATER OUTLET, W/ BALL VALVE DOOR BOTTOM DOOR BOTTOM AND 8/A3.0 HERE 6'-0 9/16" SHUT OFF BY G.C., HOOK UP TO WATER 5TH DRINK COUNTER '7( 44- INLET OF ICE MACHINE BY MANITOWOC 6TH SEE SHEET F-1.0 POWER OUTLET FOR SODA 011) DISPENSER BY G.C. . . DRAWN BY: SAR VESTIBULE ELEVATION 0 NORTH DINING ELEVATION e . SCALE:1/2" = 1 '-0" SCALE:1/2" = 1 '-0" .... . ,. . . ,. PANDA PROJECT#: S4-09-D2116 ARCH PROJECT#: 0821 ARCHITECT: CONTINUOUS SINGLE RADIUS GYP. BD. (T-95Y) STROKE OF RED NEON SOFFIT RPG 1 2'-0" A.F.F. Qk - , NOIT: \ / , : , ----T i i i . / i ! ' B.O. LAY-IN CLG. l REITER DESIGN GROUP ALL EXPOSED EDGEF., Of WALL 111E \ , 1 ; I ' MUSI Br. rtNr.mrD 10 MAJC1 I / I I ' (P-9 ) ARCHITECTS, INC. SURFACE FINISH. E_ASE FIEF EDGE_ AS \ , (P-9D) ■ / . I i , 7965 SW CIRRUS DRIVE A[1 OWABLE ! , , I 1 1 10'-6" A.F.F. $4 BEAVERTON,OREGON 97008 \ , / i ! ROUND SOFFIT (503) 574-3036 FAX(503)574-2916 . i i i , I { . GENERAL DECOR NOTE: ALL WALL DECORATIONS, PRINT / - • - - - • - • - ' - • . -. . -. - - - - • - • - • - - - • - ' - ' - ' - - I °CATIONS, FIC. 10 HI VI-RI111 0 Wri I I \ , PANDA EXPRESS BY C.C. / I I I I [ I G.C. SHALL PROVIDE AN y snrciAL \- PANDA / STAMP: REQUIREMENTS OF DECOR ITEM .. _.___. _______.__________________________.___________. IftifAl I ALION ON10 WA! I S (HON-N "MURAL / I I MENU BO RD 17'-6 5/8" 2'-6 9/16" I I 1- 1 c„ Alit) BLocKING, ETC.) (NO -:>1\INT OPENING 1-i'-6 3/4" X 2'- 5/8" CLEAR 1 (P-90 ••" gGEORGE T. ROBISON 't"4 yA PRI)itER\ONLY ' I I I CF---9-E) S, 00TH FINISH) . 014 . 0 0 r) / . , 3_,PORT .2N5D,20OREGO,N \ _L __L __I I I L_ 0 (iib • Li —i / \ ___. ._ ___, _ __ _,_ .. .___ ._,.... ____, ...._ . _ - _. -6!-8"--A:r.E. -- - ---- - ---- - I ‘./.7z, / ... ....._...........________ ___ _ __ „_ _ Ali _, _ _ .._._ _ __ _ - .___, ._- -- - B.O. SOFFIT 0 04)‘1 FULL 1-11\_ \ KITCHEN BEYOND T , / A40 START LAYOUT\ CD QM — — — ____ .-- -._ ___ ____ _ ._ A4.0 . . - - / HERE ,\ / ____ - ___, ____ _____ - - _ _ ___ .__ __. __ 40) CIO I--- _. ____ — ____ _____ , - _--il ri-- -- rr _ - 11 R90) — -- - - fl _ -- ---.. lf It 11 .-.-- ---11- 1 I r ––1 ---- -_r- --.1 _ II II II II / 1 1 - .-A__ it _____ ____ - -- (-- PANDA EXPRESS 4- „ ,, __ ___ . i____ ___L i r.i--__---....--L --___ _ - - ..._ / '• . _ _11_ _11_,--- II _ _ - B B ji _II [3---- - E3 E3 B 1 C::3 i_ ...1 C::3 -'-'-' ------- _._ ____. — TIGARD TOWN SQUARE _ _________ _____ _f_____ ____\_._ _ -.\ ------- ------------- \ ./ , ao 16230 PACIFIC HWY. SUITE 100 i \ I --11 , TIG. AR. D' OREGON . • . .„ . . / IN ., FULL TILE SERVICE COUNTER, START LAYOUT 44.0 SEE 3/A3.0, 4/A3.0 HERE (T-98) (T-96) (T-96) (T-97) (1-93) (T-98) (T-96) A MIMI 2 . 1 WEST DINING ELEVATION SCALE:1/2" = 1 '-0" INTERIOR ELEVATION S • • • • .. ,..f •. • • • a • ,« ;.• .•.::.. !ft,r•, ! ,.-. - FULL TILE FULL TILE FULL TILE FULL TILE =„ :_,_ - - P0 10 I I F T ACC S S 0 R Y S C - D _ F START LAYOUT START LAYOUT START LAYOUT 6 START LAYOUT HERE HERE HERE ) HERE N 0 DESCRIPTION t I ' 1 r�-- -- : it?•:• •: F::::1:-::::r--' ::-:-:- --- :-- .:-- :�:: - i I -1 REVISED 02/13/06 t I .�.__.�......::.::....�.:::: ,.::. : �::::. ..:.�....._., 1 ; i I ► I �� _ ! �r _ BOBRICK GRAB BAR 36 LONG ;- -. _ _� __ -::•:ti j::::: - :--�:::::� :.I .::: ::•:-:, -; j-_ ;_ ; HizJ _ _B 6806 SATIN INISH RU i a j / i i RMS 1 r_ II BOBRICK GRAB BAR, 42 LONG kL f r - -...+.... ,b j__ ,RG42 1 RG42 ---,tf: :::::•:! r-::.: I \ 1 r--- B-680fi 1 1/2" SATIN FINISH _ _l ,__/__L____, .l, - RG36 _ ( : �:.:_: :::::'::::_ ..- , ^ HL- I _ 1 - •i n■c I i { ©T OD 20 3 8 W X 30 3 8 H 0RT =••r > "-=`�--�:: ::r �r:::':- :.. ...:.:::.: ..:.. .:. ::... 1 - � } ED)� / / � [ I "' r`' -� I I_ i - I , NK BACKSRT 1 I � < ! � � , � �. ' � SHALL CONSIST OF THE FOLLOWING: 'P � SOAP DISPENSER ` �. �F RS � � � STAINLESS STEEL �---\-------________.______._� T (BY VENDOR) (T94� RMT (T94� PROTECT PIPES FROM H TD (� T94 KICK PLATE �T94� - BLOCKING @ALL RATED WALLS AND AT WALL UNDER C y I N __-.__.___.._---___---.-_.__.___------_-___.__-._-- ----------------__-- ------.--..___.-__-------------_-_— ---___-_-- A B HOT AND ABRASIVE SURFACES l.� D MEN N BOBRICK RECESSED SEAT COVER DISPENSER — EXHAUST HOOD SHALL CONSIST OF 12". 18 GA. METAL RMS B-301 STAINLESS STEEL, SATIN FINISH FULL TILE FULL TILE FULL TILE STRAPS INSTALLED PRIOR TO INSTALLATION OF GYP. FULL TILE START LAYOUT START LAYOUT START LAYOUT P60� START LAYOUT BOARD @ALL AREAS REQUIRED FOR FASTENING PANDA EXPRESS INC. SANJAMAR TOWEL DISPENSER (AUTOMATIC) SANJ-T1400TBL HERE HERE HERE HERE EQUIPMENT SECURELY TO STUD WALL. TD i i ; I 1 , I 1 -: :1::-::•it:':::::::'::-::::,•:::-i.:::1':::-:-::::-i:_:::: _-: -1::.:-: 1 1 I I i __` 1683 Walnut Grove Ave. CLASSIC ARCTIC BLUE 15 1/2" H x 13"W (PROVIDED BY PANDA INSTALLED BY G.C.) -_- �_-- - 1 t-� ,<- •.•- :: i__ I - -I =,-::.::.�:: :�.,..-1::�-- .r.-.-,.�:_� .� � ,_ i ,- � L_� Rosemead CaliforniaI _ -------.___.- -_----------------------------. _�_�_____. _____._ �_-_��-_._-- -.------_..__--.--_- --.-----_.__. 1 95R :::: . :::. :::::::: ,.:.:::::::::'; Y,::•:-: - - 1 1 , 1 91770 �- `i __ --. _ ' ^-' — BLOCKING @ ALL OTHER WALLS SHALL CONSIST OF RMT BOBRICK MUTT-ROLL TOILET TISSUE DISPENSER __ =-=- '==- -=----:=- :-I: B-2888 STAINLESS STEEL SATIN FINISH _ ` I 1 i :::=#•��::- :-::-: :::::�::::• :-}:-,:-::�:=:-: RM ., >/, - -- i ! 1 � Telephone: 626.799.9898 }•=' \ 1' S 8" PLYWOOD SHEATHING IN PLACE OF GYP. BOARD i - - - 95 __I:5- '> - I -- ........ .....:: ::..a::::j:::::�::':::::- _- - ! 95 Facsimile: 626.372.8288 I -! „ RMS ::::: :: ::::: :-::::: ::_:a::::: _ _ - _ I ; _ _ WITHIN DASHED BOX AREAS. FINISH OVER WITH AMERICAN STANDARD FLOOR MOUNTED ELONGATED TOILET 1 �� _ RT i I ; i -._::1 :-:j::::� :: : =t: •::i :::,-=- ---- - = RL RL f p t I �I ' (- I CADET 2168.100, WHITE _--- RG42 R �. ::::::�:::::—��;`::, ,::::"[:.:::.*::1]....::;:::::::::::": - d _ U - c �- -j — SPECIFIED WALL PANEL FINISH PER KITCHEN ELEVATIONS....,.„.. .. .- C r-7 G36 _ .. - / - . _ . , RL 1 AMERICAN STANDARD WALL HUNG LAVATORY = — - ``� _ - - ' ' �_ :=-'}= - -- 1 -� ``� - ';� .:, I:::-I =i='= - 1 -- i I —I j Ali ideas, designs, arrangement and plans indicated DECLYN 0321.026, WHITE h__ __ e = :::- ::: :::�:::__:;: }:-_::-:::::;:__:i:: _=::= I _ I �- — — I I I 1 I represented by drawing property< RT r :::::::: -} -� - d O d cV 1 ( or re resented b this drowin ore the ro ert of --- - - '' :::•t N r� d- ro ' — Panda Express Inc. and were created for use on RU AMERICAN STANDARD URINAL ''ti ,-� 1 \ ` \ this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed STAINLESS SH±L to any person, firm, or corporation without the 6601.100 LYNBROOK 1.0 GPF WITH SLOAN ROYAL #180-1 FLUSH VALVE (T94) RMT T94) TD (T94� KICK PLATE T94 written permission of Panda Express Inc. E F I- G WOMEN - —! MEN BOBRICK SURFACE-MOUNTED SANITARY NAPKIN DISPOSAL - PROTECT PIPES FROM — — RD B-254-STAINLESS STEEL, SATIN FINISH HOT AND ABRASIVE SURFACES INSULATE TRAP & HOT WATER AT HANDICAPPED LAVS. RESTROOM ELEVATIONS GEN. WALL BLOCKING NOTES REVISIONS: RESTROOM PARTITION BY GLOBAL, STAINLESS STEEL FINISH SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1'-0" A A A A A A A STAINLESS STEEL ENCLOSURE AREA REQUIRING FROM TOP OF HOOD TO BLOCKING RE: CEILING BY G.C. 1/A-2.2 ..� .. _ .,, : . -; , : � . - � :�;,_ ;_ _ _ AREA REQUIRING FABRICATION DIMENSIONS OF SERVICE AREA SECURITY MONITOR BLOCKING RE: ENCLOSURE SHALL BE ISSUE DATE: SOFFIT AREA REQUIRING BLOCKING 1/A-2.2 VERIFIED AND MATCH HOOD (P64) RE: GENERAL NOTE 1/A2.2 SOFFIT FIRE SUPPRESSION DIMENSIONS. 1sT PERMIT APPLICATION 01/09/09 TANK 2ND (WP1) WP2 \ -- - (WP') \ i 0 J 3RD SS EXAUST HOOD (W1� MENU BOARD 17 -fi 5/8" X 2-6 9/16" \ k: *®w , I ,, »1'-3" ,° _ ` ` OPEN TO DINING '" - 5TH OPEN TO DINING OPENING 17'-6 3/4" X 2'-6 5/8" CLEAR �/% / i 9 7 -7 9,,1' 9 3 -6 94%1'-9 Z -- _ i/� / / / / �' \ ' 6TH :2 - `` - OPEN TO SERVICE AREA -- 1 _ CWP1� _ �' 1 i/ WP3 BEHIND COOK LINE -t-- �f �I _ I �. �` (-D -y - - - I C-a C3, I----I L��• i�l�:i� �L_L i`_y _L, __ \� L�_ _, '�-��.•, ,_:_•.�-. --- ---- ...---,,' ,, . 1 ,,,,::::: a - !�__J ' I� - — C-) - -_------_____ __�_ _.___I_ t' �` \• ' _ ►�, - ' d d ,a DRAWN BY: SAR �._e d ry / p , , u u , u u a O _ ..i� i16 a fit• N L-FT- 4 LIMIITIlj`_' j I ' 1 E I'LO 1 I .---g E"_---i- il t ..... -al _ _ . al LP - f - :ca. I � J �'l�������111���1BI��1����i1 11S�1 ,� ! f Ti �I � � -� I I I I 1 I I I 1 L � `" tl//���/1���,� ,, ~ i;�i l i i i����l l l l f�//��i��t l l�i I'�Nll�l�I!IIII 1 I i Mil i -��,�v Mill - \ \ 1 1 I 1 I I I I I 1 1�_ I I lU I! I � { I I lE II I I 1 I [ 1/( I . I SAFE F.S. .S. F.S. PANDA PROJECT#: S4-09-D2116 (QT2) ( 84C (34H) (32G) (34A) QT2 (QT2) (21D) QT2 (20A) 21D 21D 20Q (25A) (24H) (81 ) (81 ) QT2 ARCH PROJECT#: 0821 (26AAA� ARCHITECT: RPG MANAGER STATION ELEV. REF. PREP. COOLER ELEVATION EAST WOK RANGE COOK LINE AND MANAGER STATIOR ELEVATION SERVICE COUNTER ELEVATION - 1'-O" SCALE: 1 4"= 1'-O" SCALE: 1 4"= 1'-O' „_ 4 REITER DESIGN GROUP SCALE: 1/4 - 1 -0 / / SCALE: 1/4 - 1'-O" ARCHITECTS, INC. 7965 SW CIRRUS DRIVE BEAVERTON,OREGON 97008 (503) 574-3036 FAX(503)574-2916 MOUNT EXIT SIGN STAMP: TIGHT TO CEILING GRID. AREA REQUIRING 4 71",i, 2'-6" 1/A-2.2 AREA REQUIRING AREA REQUIRING ''� 40 BLOCKING RE: BLOCKING RE: GEORGE T. ROBISON'C� BLOCKING RE: © 59" 1/A-2.2 1/A-2.2 ! r •JT I PORT D, OREGON „ . .e/4 { (wpi) WP 1 2520 7.4.1(WP-0 (WP1� pT -7=7777'7-- V #./ t .i/.i/. (WPO 8'-0„ 8'-0" OF �� %iilifi� (WP1) ir f f /:40/.,l � . . _. , 0 I : 0 Liril❑ P67 •{ *--:-/ L._.I 1 1 ' ...,. c 0 ,,,, ., ,.! , il , _, ? ri T ri r it 1 1 LV-in PANDA EXPRESS 1 ii,.=. • • Si rd r .17- NN, NO I a �, t , .-..� n t ! � � �� � � •� � ��� � _ `0 TIGARD TOWN SQUARE r -! N I i --r � L-- , . t t 1 it_ It L._.1 N ■mumumsuu�ii1a�1i •ausm•aaat I I F 1 T I II I I I I I II I�I I I I I I I I I I ■�RUIRR1$11AWI`vu�'u3!IIIIIRU I !AIL!1a*1!I�1a*t►1*II��IIU•11 RUIIt11 ■I!1 IIIUUSIi1000I11aa11tt1I1U■ I iA F.S. F.S!• 16230 PACIFIC HWY. SUITE 100 F.S. TIGARD, OREGON 6" HIGH CONC. BASE(P1 ) (55) (55) QT2 (4D) 6" HIGH CONC. BASE(P2) 44C QT2 61 A QT2 41 JA 41 JB (10J) 40A (QT2) W/(9 T2) FOR WATERHEATER W/(QT2) FOR CO2 TANK A-2 , 2 KITCHEN ELEVATIONS MOP SINK ELEV. MICRO ELEVATION CO2 AND SODA RACK ELEVATION ICE MACHINE ELEVATION 0...p VEGETABLE SINKS ELEVATION 9 POT SINK ELEVATION 8 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4"= 1 -o SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 A • • ROOF STRUCTURE - PROVIDE BLK'G ,,\\ - @ BOT. OF TRUSSES WHEN CONDUIT /' `�' \\ // \ ._..E FALLS IN BETWEEN -----RUN WIRE THRU CENTER ,; 6 CENTERLINE OF o OF CONDUIT - CONNECT `� DOOR AND SIGN 3 » ' » ,ep_/4 CONDUIT COMPRESSION STRUCT TO ROOF STRUCT. WITH \` /' \ -' \ ' 1 1/2 S.S. TUBE WITH ROUNDED CORNERS - _ , .�� SATIN FINISH WELDED & 3/4 RADIUS s 0 -�' _ _ `� PRESSURE FIT BETWEEN ROOF EYE LAG SCREW GRIND SMOOTH AT TURNS „ STRUCT. 8c CEILING MAIN RUNNER FABRIC: JOHN BOYLE �, gNLINE ETER „ - 1'-0" DIAMETER , 3-#10 SCREWS F SIGN @ 12 --0 O.C. EA. WAY WITH -WRAP WIRE THRU SIGNMASTER SUPREME w r ~ FIRST POINT WITHIN 4'-0" OF PREDRILLED SLOTS IN #604 RED SUPREME A ROOF TRUSSES CL ` V� PERIMETER WALLS PER UBC - RUNNERS 8c AROUND �� 0 ,..,/ A 0 BOTTOM OF CONDUIT REMOVE EXIST. - 20 GA. 4" MTL. STUDS „ PERIMETER WIRE @ MTL. ROOFING V'- ALTERNATING @48" O.C. • © X01' • 5 -o... .4 EA. TERMINATION ----4-12 GA. ■ 12 ' A.F.F. POINT SPRAY WIRES \. ' `\ ./\\ G O „ 1111 T ) 44. 8' MAX. ---- „/i ii \ %-x--_---,-----,:,,,; ? '--;-.7-r '';- ,. -,/ 1154 �' 4 i' ! WHITE 71P----\\ CEILING PER PLAN - 1/4" THICK EQUILATERAL • 1/4" THICK ROUND j • j MEN'S ROOM SIGN WITH WOMEN'S ROOM SIGN WITH i EXISTING AWNING AWNIN SHOULD EXTEND - 5/8" GYP. BD. PANDA EXPRESS INC. GRADE 2 BRAILLE GRADE 2 BRAILLE , FRAME-PAINT BLACK BEYO D' WDW FRAMES � METAL STUDS --C-2 - CROSS RUNNER SAME EQUAL DISTANCE, CEILING PER PLAN I /, 1683 Walnut Grove Ave. @ 2'-0" O.C. TYPIC L. Rosemead, California NOTE: ALTERNATE BLACK & WHITE \ ,, „ r �► ' 91770 SIGNAGE COLOR AND LEI IER SIZE SHALL COMPLY - -FACE OF WALL MAIN RUNNER MODULES PER PLAN I y H(LTi POWER DRIVEN PINS 12" X12" SQUARES ON 45 DEC ANGLE SEWN TO MAID AWNING @ 24" O.C. MAX. Telephone: 626.799.9898 WITH LOCAL CODE AND ADA REQUIREMENTS. @ 4'-0" 0.C. WELDED FLUSH ELBOW \ CONNECTOR Facsimile: 626.372.8288 TOILET SIGNS CEILING DETAIL AWNING DETAIL TYPICAL PARTITION DETAIL QUEUE RAILING DETAIL :.. NOT TO SCALE NOT TO SCALE SCALE: 1 1/2"= 1'-0" SCALE: 3/8"=1'-0" SCALE: 3»=1'-0 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of 3 Panda Express Inc. and were created for use on TYP this specific project. None of these ideas, designs, 1 1/2" S.S. TUBE WITH arrangements or plans may be used by or disclosed �� �� KITCHEN CEILING to any person, firm, or corporation without the SATIN FINISH, PROVIDED BY written permission of Panda Express Inc. O LEGEND: SEE SHT. A-1.1 T-BAR CEILING, SEE PANDA & INSTALLED BY G.C. 1 NOT USED .f i f `: SHEET A-1.1 , 1 1/2" O.D STAINLESS STEEL f 162" UAI < s �n_�. ___E =, = _ TUBE SET IN EPDXY GROUT 1 1 DE > EQUAL EQUAL - REVISIONS02# CS AT H INT,TYP ; 5 ; MTLF @ \4 ;o , ' 0 . » �' \ �� -'r ( 4®GYP.BD.. FINISH PER ARCHITECTURAL , 1/2 t ` t 1 / I' . 1 t� DO NOT PENL I RATE \ ` \�P �. � , © OPREMANUFACTURED OPEN WEB Eft ' VAPOR BARRIER / `__ / / 4 �l 1,y WOOD TRUSSES LEGEND: 1/2" BOLT @ 36" O.C. T 1/A3.0 1/A3.0 1/A3.0 n A roK© ®WOOD TRUSS BOTTOM CHORD `�/rn' ®NEW 2x4 DOUGLAS FIR (LARCH) #1 °� FLOOR TILE _' ' ` ` F OR #2 @ 24 O.C. WITH SIMPSON MENU BD. MTD. TO ( o l�KITCHEN I t'�ALTERNATE DIRECTION 0 LU24 FACE MOUNT HANGERS (OR METAL FRMG. w ' CONCRETE SLAB ►� 8 CEILING SEE i r 0 DIAGONAL BRACES EQUAL) AT EACH END `� 1 1 SHT. A-1.1 ; ; 24" orb ` 12" ® x 20 GA STEEL STUDS @ 24 SERVICE KITCHEN . i , r , t') 27:972727127277717/17717- ow,,w9'ow)7 II r, 7_I°'I r»riri177.4,77 r•��r/7//7.,/177.17777%/7".6977/717724,,i,7717Yz �e' ` %' NEON LIGHT d0# 10 SCREWS AT EACH JOINT, 4. I ' l ' ; ; �•; 4 jw TYPICAL 1/2" BOLT @ END OF SOFFIT ) $ z.' n , -_ 0 z 1 1 1 INN i ,,, ISSUE DATE: _--t If...-'1 00 ®GYP.BD,. FINISH PER ARCHITECTURAL TYP. 3 ON EACH END j T v / \ • , ` t�5 PREMANUFACTURED OPEN WEB - F �" 1 ' a J a 1sT PERMIT APPLICATION 01/09/09 ® 10„ ' WOOD TRUSSES 7" `1 / 2ND /_____________.____._ 3'-0 t' » / ()WOOD TRUSS BOTTOM CHORD \ / 3RD ()ALTERNATE DIRECTION OF 6/A3.O DIAGONAL BRACES 4TH 5TH 6TH SOFFIT DETAIL » 18 14 MENU BOARD COVED LIG - TS 10 QUEUE RAILING BASE DETAIL 6 QUIUE RAILING ELEVATIN REF:A-1.1 (REFLECTED CLG PLAN) FOR DETAIL REFERENCE SCALE: 1/2 =1 -0 NOT TO SCALE SCALE: 3 =1 -0„ SCALE: 3/4"=1'-0” - 1'-8» - » 4" 101" » 4'-0" TYP DRAWN BY: SAR SQUARE 5/8 GYP.BD. _� y____.___-__ 2 l _ P�. -.---_ ,7.-r-_-- � - ------ - - - ---->�TQP OF S.S. W 0 FINISH ' - _ -_. ': - 18___ - 1 1/2" DEMOUNTABLE PLYWD. COUNTER -- 1 I 8'-3" A.F.F. T.O. t DASHED LINE 18" " ',=� INDICATES EDGE Ilk �� `' 3/4" PLY. WD. I J 7 SHORT WALL PANEL Wj WOOD VENEER POCKET OF STAINLESS A80 STEEL EQUIPMENT. (PL61D--- GR61 ` - (P L61 (PL6D �PL6��-1 PANDA PROJECT#: S4-09-D2116 V /:/-1 ..,:<-1 \\ :! - ARCH PROJECT#: 0821 'L. 1._, _:�_ _ , , , �i 1 i- ,_ ,. ,. . -, , ,. . -,. _ •,. -. '• _- '- ,. ., , 9/16" HOLE / ,..:�; : ., : _, V. ,` • -, -TRACK LIGHT ,.�I'.. , .,_!�,.' �,_ .,_,. .,:,. . ,. ,. . :,. 7 -9 A.F.F. I I , , ,� , ,. ',. .. -,. . . . . .. . . . . . . - -, SAFE BODY 1\ �`\ ` ''!i:''!i:'-!i:' !- - ' ' �- , ,.' ARCHITECT: 7'-4" A.F.F. �' \--EXHAUST HOOD-- is :: 3/8 0 A.B. w/ 1 \ -i:�GR61 ; , ,.- It ►� _ T.O. RESTROOM \ : , SPRING WASHER CEILING " :'= G61" - , •, , . & NUTS /'_"--5/8 GYP.BD. - - - -,. - P -to RPG LAN / ~ 5/8 TYPE"X" GYP.BD. / TAPED & SANDED li - -,,- ,•,- ,- ,-, ;"', - ,:,.:,<,:<:,'•;:<•,• - •' z L. NEW 6 TAPED & SANDED W/ �\ W/ FINISH (P-A) ,\ 1" X 1" S.S. ANGLE ; \\ ° a; a..` CONC. CURB FINISH CP—off \ WITH S.S. RIVET @ 24" 0.C. " • '/ kEITER DESIGN GROUP • c° EXISTING / PROVIDE & INSTALL BY G.C. I ARCHITECTS, INC. .'Q: .. CONC. SLAB \ ;r, -- 20 GA. MTL. ri`-y 18" ( 7965 SW CIRRUS DRIVE l BEAVERTON,OREGON 97008 % - --- (WP3) (503)574-3036 FAX(503) 574-2916 \,.- _ ' 3" DOWEL w/ ).-- - - - - SIMPLSON - ------\�.. -(T61 B) , » - PL61 '-{T61 B� SECTION EPDXY TYP ( ) .1 -10 NOM. . A—PLAN A—ELEVATION PANEL STAMP: ARc CONCRETE PAD- SAFE E DETAI L 1\ g SHORT T WALL CEI LI I\ G CURB DETAIL HOOD TO WALL CONNECTION TRAY SHELF DETAIL TRAY SHELF ELEVATION '/1,... GEORGE T. ROBISON v....A NOT TO SCALE NO SCALE NOT TO SCALE SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" \ - GRANITE GR61 ON COUNTER TOP-- GRANITE GR61 ON COUNTER TOP-1 • <SX�-'• `• r \ PROVIDED BY OWNER, INSTALLED BY G.C. PROVIDED BY OWNER, INSTALLED BY G.C. I PORTLA o, OREGON , . INT. FIN. OVER 5/8" GYP, BRD. WALK-IN CEILING PANEL - ,,i /1 �' 2520 Q ..;- 2--- STAINLESS STEEL SERVICE COUNTER 1:7).4.7 sl,SERVICE TABLE W/ I J / _,.,• \. BUILT—IN STAINLESS I t 1 �� 2X BACKING / I �.y' fi ff.- _. CLR. SILICONE NOTE: STEEL SHELVES J {; ; . ::�__ GR61 , WALK-IN WALL PANEL --- PROVIDE WALK-IN FREEZER I T="%;" ' -(GR61� 3/8" �� G.C. TO FURN & INSTALL r .L... MANUFACTURER FORM PLASTIC I '''c., 3/8 CLEAR GLASS AT FRONT ,�'' ` I "Z" - INSULATION COMPLIANCE LABEL -- 1.___ S/S Z BAR 2 SIDES I ,�" PER OSSC SECTION 2603.2 WP-1 OVER 5/8" WATER I - PREFABRICATED WOOD 1 2 CLEAR GLASS ON TOP FRAMES PROVIDED BY -- _______________ PANDA EXPRESS {PL61� I: - PANDA, INSTALLED BY HATCO DISPLAY LIGHTS - 1-= --------_ I „- I - - _ _ ,'� G.C. ; '_ '• _ ,�_ G.C. TIGARD TOWN SQUARE 4 /2» _ ------ 60" A.F.F. 1 1 5/8" 1 1 3/4" I 7 ( 1/2" DEMOUNTABLE 12" HIGH 5/8 W.P. .�----- -.t- --- _ -._ ___ ___ _ 54" i t — PLYWD. » 11 1/4" N { PLASTIC DLAMINATE \�; -_-- 54 A.F.F. L — i `: METAL COVE BASE 1" x 1" PLYWOOD GUIDE rni �-\, Ira Cam- __; 1 '- WP-1 OVER 5/8" WATER„ �.� • FILL ALL GAP SPACE NAILED DOWN PREFABRICATED WOOD - co 16230 PACIFIC HWY. SUITE 100 �''��' BETWEEN MOP SINK AND SUB-FLOOR PANEL 1 1/2” HILl] SHOT PIN FRAMES PROVIDED BY O GECSISTANT GYP. BD. BY I N TIGARD, OREGON 0.- 1 r �, WALL WITH FOAM. �: @ 24" O.C. (ICBO 2388) PANDA, INSTALLED BY - - - {PL61� MOUTH ZONE ► '. G.C. 0,; �► 24"X24"X10" MOP SINK \ I M 1►, - SEE K-1 \\ , SILICONE SEALANT SERVICE I L _ _ _ _ _ r! . SERVICE O CUSTOMER ��� T ? T CUSTOMER --; : ii ` COVE BASE TILE t I -.- , I ___Og 11:1 ►� SET MOP SINK IN \ I m . •-. il T i i r it �,�� / i; MORTAR BED I I ? ._-- -.- ----{T61 BD 1 i -------- -- --. -_ . -_----(T61 B) A.....3 • 0 iIId ' °�- 1 �.���,..= QUARRY TILES UNDER SPREAD FOAM BEWTEEN QUARRY -T/70,�.,,,,,, 1, �, - . — d. SUB-FLOOR PANEL TILE AND SUB FLOOR PANEL QUARRY TILES - COVED BASE TILE a • - • . - .. - - .. a .• a QUARRY TILES •- -- COVED BASE TILE - ARCHITECTURAL SNEEZE GUARD D -TAIL MOP SIN TYPICAL WAL'( - IN FREEZER SECTION • TRAY SHELF DETAIL TRAY SLIDE COUNTER DETAILS 4 DETAILS SCALE: 3"=1'-O NO SCALE NO SCALE SCALE: 1 1/2 = 1'-0" NO SCALE • • _ _ _ _,_ •• --% . . -11.) ,. . - iN E _ 33 . . .. .... . X A. STUCCO SYSTEM ;' { EXIST. 2X6 STUDS . .. • . •. . . .01 - • (MATCH EXIST.) - a V eo STUCCO SYSTEM/ p:;;;c:: ST, WOOD - : : :" . TI.FOR FN, / . �;,`I 1 2j FT C NES� BACKUP ROD BACKUP ROD H AND SEALANT ii AND SEALANT • aDoi "'` — m CAULKING PANDA EXPRESS INC. { ALUM. WINDOW FRAME 1683 Walnut Grove Ave. � r CLEAR ANODIZED 1C ALUM.WINDOW FRAME j.1 CLEAR ANOD1zEp Rosemead, California AND INSULATED GLASS A AN INSULATED GLASS 91770 ---4.--- B ' Telephone: 626.799.9898 ^•./ _ ti Facsimile: 626.372.8288 ALlik 9 S ALUM.• WINDOW HEAD 1 WINDOW HEAD DETAIL . . . .. . A31 A31 A31 3" = 1'-0" 0821-D104 A31 3" = 1'-0" 0821-D100 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. V EXISTING BRICK ;;r %. REVISIONS j4(/ A A A — / I Aril lig A ALUM.WINDOW FRAME .1111111 ALUM. WINDOW FRAME . —1. -.._ :,--iiimA CLEAR ANODIZED CLEAR ANODIZED Q { AND INSULATED GLASS ` AND INSULATED GLASS r\SI 1/4 WOOD SHIM / \ / AND SEALANT ALUM. DOOR FRAME = ISSUE DATE: WI TEMP.GLASS /--, — GLASS " r SEE FINISH SCHED. 1ST PERMIT APPLICATION 12/18/08 5/8" GYP. BD.SEE INT. ELEY.FOR FIN. 2ND LINE OF TILE BEYOND 3RD 4TH EXIST. 2X6 STUDS 5TH 6TH C6) ALUM• DOOR JAMB WINDOW JAMB DETAIL ��� 1Q� 2 X431 A31 3" = 1'-0" " _ '_ „ 0821-D108 A31 3 - 1 0 0821-D103 . DRAWN BY: SAR STUCCO SYSTEM PANDA PROJECT#: S4-09-D2116 (TO MATCH EXIST.) ARCH PROJECT#: 0821 EXIST. PLYWOOD SHEATHING BACKUP ROD u 4 SEALANT ... . .- . = ARCHITECT: %iii%%%riAIIlar%� ALUMINUM WINDOW EP ALUM. WINDOW FRAME CLEAR ANODIZED I CLEAR ANODIZED REITER DESIGN GROUP I R P G iimmi i ■ . AND INSULATED GLASS ARCHITECTS, INC. X --W ALUM. WINDOW FRAME �X 1/4" WOOD SHIM 79b5 SW CIRRUS DRIVE ALUM. DOOR FRAME INSULATED CLEAR ANODIZED W/ TEMP.GLASS AND SEALANT BEAVERTON,OREGON 97008 GLAZING AND INSULATED GLASS SEE FINISH SCHED. — ./; (503)574-3036 FAX(503)574-2916 5/8" GYP. P.SEE INT. ELEV.FOR FIN. LINE OF TILE BEYOND STAMP:�}}.. EXIST. 2X6 STUDS t, WINDOW INTERMEDIATE A � GEORGE T. ROBISON All% (r\ VERTICAL , ALUM.• DOOR JAMB ci--) WINDOW JAMB DETAIL A31 A31 SCALE: 3" = 1'-0" 0821-D026 A31 3" = 1'-0" '_0.1 0821-D101 ,43 3 = 1 0821-D102 3POR ND, OREGON 2520 11,Z) OF C Q - .e- BACKUP ROD ,o AND SEALANT NI- INSULATED GLAZING PANDA EXPRESS � '—' )1"r N -< ALUMINUM WINDOW ALUM. DOOR< W/ TEMP CaLASFRAME CLEAR ANODIZED TIGARD, OREGON SEE FINISH SCHED. SI-!I1"t n1T�11101 ‘...._.04411 .1_��' Z�� SEALANT D. ± 1 - ALUMINUM WINDOW CLEAR ANODIZED SWEEP STRIP 1 PACIFIC HWY. SUITE 100 �� 1 TIGARD, OREGON NO III I I- THRESHOLD INSULATED o GLAZING CERAMIC TILE -4. .. , (/// (SEE FINISH) N rY `-j < _ . WINDOW INTERMEDIATE 1 ,... o • d% 0 16 12 HORIZONTAL $ ALUM• DOOR SILL 4 WINDOW SILL DETAIL % A31 A31 SCALE: 3" = 1'-0" 0821-D025 A31 3" = 1'-0" 0821-D105 ,�31 SCALE: 3" _ 1.-0" 0821-D012 ARCHITECTURAL DETAILS N co O • I" •S • • •• • «.;,• •. . • a •; . • EQuipmENT SCHEDULE S4-08-D0000 2-25-08 -- --_ PLUMBING ELECTRICAL DESCRIPTION -E-)fin7i FS INDIRECT CONNECTION TO FLOOR SINK D DIRECT CONNECTION 0 OWNER(PANDA EXPRESS, INC.) S SERVING AREA _ - D DIRECT CONNECTION C CONVENIENT OUTLET GC GENERAL CONTRACTOR K KITCHEN Is-- fp- ciP RIH ROUGH IN HEIGHT (TO CENTER OF CONNECTION) FS FLOOR STUB OUT EC ELECTRICAL CONTRACTOR (E) EXISTING rW , DC DROPPED CORD KEC KITCHEN EQUIPMENT CONTRACTOR 44. ‘\\, (i) 0 0 SUPPLY GAS WASTE COLD WATER HOT WATER CONNECTION LOAD PHASE H.P. VOLTS REMARKS DIMENSIONS MANUFACTURE MODEL# EQUIPMENT NO. Q BY � - O O K BTU R.I.H. SIZE TYPE SIZE R.I.H. SIZE R.I.H. SIZE R.I.H. TYPE WATT W x D x H (0 x H) G O SERVINGAREAEQUIPMENT -, r- -1 -P,A (< 20" 1/2" SEE DETAIL SEE PLAN KEC CUSTOM SERVICE COUNTER 1 J ( J T C H I N E�' 24" D 1500W 1 115 SEE DETAIL SEE PLAN KEC CUSTOM SNEEZE GUARD 2 421. • FS 1/2"-1" 24" D 3600W 3 208 USE 15 AMP BKR CUSTOM STEAM WATER WARMERS 3 J I I PANDA EXPRESS INC. FS 3/4" 16" C 1.5A 1 115 W/LID DISPENSER 3O"x30"x35" CORNELIUS ED-2000 BEVERAGE DISPENSER 4AB J 1/2" 96" C 7.2A 1 115 ON S/S SHELF 15"x11"X16" -CORNELIUS CARBONATOR 4B T I 1683 Walnut Grove Ave. --r Rosemead, California 29"x18" CORNEUUS SODA RACK 4C �� I a 1 , n n 9 n n ON 6" CURB X20" CO2 TANK 4D �, -+� w ;j^ >♦� I Q� °�y 91770 " " CARBONATOR F } --'�' %� 1i- ---0" Telephone: 626.799.9898 SEE ELEV. DWG 24x18 _KEC CARBO A OR SHEL 4E r�, �/ Facsimile. 626.372,8288 96 1/2" WALL MOUNT 20 x4 x20 EVERPURE WATER FILTER 4F - ' ,� FS 1/2" 24"x24"x6 1/2" KEC CUSTOM 24"COLD PAN 5B o ago i w WI TOWEL & SOAP 33"x24x36" EAGLE S.S.HAND SINK W/CABT. 6F ' ° " ° I I I� I _•.__.-'--•// •elf i S FS 1/2 32 1/2 32 D 7.8A 1 115 --- 34 X 22 X 66.5 MANITOWOC QY-0424A 400 LBS.ICE MACHINE 10J , All ideas, designs, arrangement and plans indicated I (7...---7 or represented by this drawing are the property of FS 1/2" 50" 1/2" 84" C 1.1A 1 115 --- 22" X 14° X 26.5° MANITOWOC IB-0824YC 800 LBS.ICE MACHINE 10K ! '' i Panda Express Inc. and were created for use on ' ' this specific p project. None of these ideas, designs, 6" D 11.7A 1 208/230 ON ROOF 34° X 24.13° X 25.75" MANITOWOC CDV-0$75 REMOTE CONDENSER 1 OKc , }__'__;__ .' tc4) 51 A , arrangements or plans may be used by or disclosed i r r -,4 �{ to any person, firm, or corporation without the try . • + +f, written permission of Panda Express Inc. • %;/, is,i j;`i ''i/,%i///i.; ,, ��; /i,/, .�.i _ K ITCHEN E QUIPMENT s� .// -- j(-/ 450 10 1 1/2" FS 2 10 3/4" SEE DETAIL 91"x42" KEC CUSTOM 91 CHINESE RANGE (L) 20A cr, ; ti --1-=-1 - l -- --_-_ no 190 10" 1 1/2" FS 2" 10" 3 4" 20Q `•/ / SEE DETAIL 42"x42" KEC CUSTOM 42"CHINESE RANGE 20 l ;Ul �. r ,, ,, „ `` -, REVISIONS: 110 EA. 3/4"X2 f, .r vJV:.rr vwx& /, % ,/'l,/, n / C 1 1 15 16 X 30 (EACH) FRYMASTER MJ35-SD FRYER(2) 21 D � 'ii cr A 24H !? ��\ FS C 15A 1 120 NEMA 5-20P 19.9"X34.5 X41.3 WINSTON HA4005 RICE HOLDING CABINET 2 3, i , - -� c W 32 30" 14" 22" x15" RINNAi PER-55A-N RICE COOKER 25A �__ y. --_ -', 4 ED ti" 24" CUSTOM RICE COOKER STAND 26A '`f' n 24 x 30" x 24 KEC Ole , , 36X8,4 :I v I I I/ '�FS 3 4 130" D 500W 1 1.5 115/208 SEE PLAN KEC CUSTOM WALK-1N COOLER UNIT 31 0 � � ' _�' .r .r __: ;. - ____ }iii i FS 3/4" WALK-IN FREEZER 32 — — - 130 D 500W 1 1.5 115 208 SEE PLAN KEC CUSTOM i .! `i + y` � �v {��h `� —— n r, FS C 8.5A 1 1/3 V...vJ.::..JJM,••JJ..:..:..A..:.::.v: --- -- 1 SELF CONTAINED 27"X30"X36" RANDELL 9404F-7 27'WORKTOP FREEZER 32G � _ °°°°° °x °° /{2 ME FS C 12A 1 1/2 115 SELF CONTAINED 84"x33"x35" RANDELL 9050K-7 84"REF.PREP.TABLE 34A :� - FS C 5.5A 1 1/4 115 SELF CONTAINED 32"x32.75"x36" RANDELL 9412-32-7 32"REF.PREP.TABLE 34H 1 -P 0 '� 0 --- 0 '� _n;■fir,■�■:■t■ , - --3 / FS 2" 14" 1/2" 14" 1/2" _ 98"X30" KEC CUSTOM-(PS-98L) POT SINK 40A 1' -._ ' 36X84 I FS 2" 14" 1/2" 14" 1/2" 1 COMPARTMENT 42"x30" KEC CUSTOM-(VS-42) 42"VEGETABLE SINK(L) 41Ja r 44A - �"I!!�Ii1 .�.-- - r- S1) ISSUE DATE: FS 2 14 1/2 14 1/2 1 COMPARTMENT 42"x30" KEC CUSTOM-(VS-42) 4T VEGETABLE SINK(R) 41 Jb 3FT r - -T— — ' ' S7 CO 4AB 1ST PERMIT APPLICATION 01/09/09 I I I I I 4- ! ° C__-_) 18GA POLISHED (WALL MTD. @ 59" A.F.F.) SEE PLAN KEC CUSTOM (NSF) 12"D S.S.WALL MTD.SHELF 43A ; I ; + I I I I I ! 2ND 5FC 15F`fl I I I I ; �t 18GA POLISHED (WALL MTD. ® 71" A.F.F.) SEE PLAN KEC CUSTOM (NSF) 16"D S.S.WALL MTD.SHELF 43B I ; I I I I I ;/,;,,,;,;''%%%%% /,,/ ,;, ;.- = 3RD » » 54" 72" 1,0 ' .:.V:.Y'.•'Y!'.7JR34FE¢dp$1V.•r'J•JN.• nMWJ.t T J cc, � .-. 4 SHELVES MTD. @ 8 A.F.F., 26 A.F.F., 54 A.F.F., 72 A.F.F. SEE PLAN GOLD BOND VARIES 18"D WIRE SHELVES 44A 0 in n RECESS / 4TH 4 SHELVES MTD. @ 36" A.F.F., 48" A.F.F., 60" A.F.F., 72" A.F.F. 24" X 36" GOLD BOND VARIES 24"D WIRE SHELVES 44C 0 U PULL BOX / / I 5TH 3 SHELVES MTD. CO 36" A.F.F. 54" A.F.F. 72" A.F.F. " 4:11 / / } P� __ 6TH 24 X 42 7 I 50 C 1 1/3 115 12 1/2"x21" GENERAL GSM-1/66 FOOD PROCESSOR 45A ! I 0_, -- J (( 1 f RI / / � I TYP. �.�=f_� t" / 7 1 2"X8 1 2"X20" # BLENDER 46A , L_ W__j "--f- .. t 50 C 1 i 2 115 / / VITAMIX 748 - , / �--, - - t i SMALL EQUIPMENT €c) ii a- - ' -' _ L if.� 741 i'/' i►� DRAWN BY: SAR WALL SHELF BY OTHER CUSTOM DETERGENT SHELF 51 A 1 + j , ' I /1/ i 2 a 4" C 100W 1 115 ON S.S. COUNTER 160 AROMA ARS-1055S RICE WARMER 54 � \`��_ _� « - 1111 i '�"- � DC 1600W 1 208 PLUG: NEMA 6-15R 20 1/8"x13 1/4"x18 1/2' SHARP R-23GT MICROWAVE 55 a. - t�, �/ ,..______ C BY G.C. AS REQUIRED BY LOCAL FIRE DEPT., CHECK LOCATION WITH PROJECT MANAGER FIRE EXTINGUISHER 56 ' _ ( PANDA PROJECT#: S4-09-D2116 a) 2" 24" 1/2" ,24" 1/2" W/TOWEL & SOAP 14 1/4"x18 1/2" EAGLE HSA-10-FK HAND SINK 57B E _u� % �' t 6B ARCH PROJECT#: 0821 1 SEE DETAIL KEC PAPER TOWEL&SOAP DISP. 58 'I i u - i/ ` i I _._. I _ I' ,—_--- = WALL MOUNT 12"x15"x78" KEC 5-T1ER LOCKER(2) 61A A t \ ;P = /// ;�; __ i _ _ _ .„ 20"x20"(+4")x23" USA SAFE B2320WD-LG6 SAFE 62A ' /r C�;j ! L _ - l ARCHITECT: PoS EQUIPMENT �+ , . o.'i ; @ ) FE,_ =0 24" C 500W 1 115 CUSTOM 11 1 4"x14 1 2"x9" RESNOS S 460 CASH REGISTER SYS.(2) 81 \ (� l 50" C 100W 1 115 SEE DETAIL CUSTOM COMPUTER 83A _�_• � I l ;` + R, P G » » » I ;i a I Cox._._ + 4$ X 28 X 42 KEC CUSTOM MANAGER STATION 84C /, O!('Thl _24 C 50W 1 115 sEE PLAN POS PRINTERS(2) s6A j+10" == i= ' , :f-N `4x, } RE I TE R. DESIGN GROUP 'M �` ARCHITECTS, INC. 50" C 50W 1 1 15 FAX 87 �' /�/ �� i f` j \' � -E P EQUIP ENT FUTUSE u �i, i O < <>' 'TIP. BEAVERTON,OREGON 97008 7 I l IG!a (503) 574-3036 FAX(503) 574-2916 132" D 1000W 115 SEE MECH. DWG. SEE PLAN CAPTIVE AIR CUSTOM EXHAUST HOOD M1 s"' c_, i f TANK •!! ;r ' � HIGH I TYP.» 83A 84C , — 1 E � n �/X 18 CAPTIVE AIR CUSTOM HOOD CONTROL PANEL M4 /; \8� %% __ C2 » » FIRE SUPPRESSION SYSTEM M I, �� /'�� wn� �--' SEE MECH. DWG 24 x24 CAPTIVE AIR 6 E4B ,,� - • �� �, 7 y __ (, STAMP: ,(4111) /Ike -BY G.C. D 3„ 36" 3/4" 36" 3/4" FLOOR TYPE 24" X 24" X 10" MOLDED STONE MSB2424 MOP SINK PI ( ,V� in / l ` ) , ,�' BY G.C. SEE PLUMB'G DWG. 30 C 115 SEE PLUMBING DWG GAS WATER HEATER P2 - � ;D ' -/' �� // GEORGE T. ROBISON 84" C 100W 1 115 IN S.S. COUNTER SEE PLAN MUSIC EQUIPMENT/SHEL. E 1 A / \ H�•'H� -..� T ` i r. i I ,( )-`- t - HIGH( - _1 __I— SEE CEILING PLAN MUSIC SPEAKER E1 B <a ;;# _-- -� • ► • .1 ---1)-:1 PORT►,•ND, #REGON BY G.C. 44 J-BOX 50W 1 SEE PLAN DOOR BELL 1 1 E3 �� �"� 2520 Q WI DOME BASE SEE PLAN PANASONIC AA-336 CCD SECURITY CAMERA E4A }� �.,, 1 1N� nn.1 84" C 50W 1 115 W/ EMI LOCK SEE PLAN TOSHIBA (TIME LAPSE) SECURITY VCR E4B 0 i � OF v - 84" C 50W 1 _115 SEE PLAN 14"X12 1/2"X14 1/4° SHARP (13" COLOR) 13L-M100 SECURITY MONITOR E4C 'P• nP• _ . , , BY G.C. SEE ELEC. DWG ELECTRICAL PANEL E7 `' SIGNAGE r :IJ) r- - ----1 T_,i _ 1 n I _ [I:LZ1I:] � � PANDA EXPRESS VERIFY D 20A 1 115 SEE SIGN DWG DETAIL CUSTOM I.D.SIGN Si - 1,___._.__ -- VERIFY D 200W 1 115 SEE SIGN DWG DETAIL CUSTOM LOGO S2 1 H � . �� �� � n c _ ____�__ TIGARD TOWN SQUARE VERIFY D 500W 1 115 SEE SIGN DWG DETAIL CUSTOM MENU BOARD S6 99" D 500W 1 115 SEE SIGN DWG DETAIL CUSTOM BEVERAGE SIGN S7 J J ( J J J 16230 PACIFIC HWY. SUITE 100 F URNITURE J J J ( J TIGARD, OREGON SEE DETAIL CUSTOM BEVERAGE COUNTER F2 J 1_ J SEE DETAIL CUSTOM TRASH RECEPTACLE F3 N . _ . . . SEE DETAIL CUSTOM 24"X32"TABLE(ADA) HT1 SEE DETAIL CUSTOM CHAIR C 1 1(1-:) SEE DETAIL CUSTOM STOOL C2 SEE DETAIL CUSTOM SETEE C3 K.... 1 SEE DETAIL CUSTOM EXTERIOR CHAIR C4 a 21"X24"x30" _ CUSTOM 24"X 21"TABLE T1 : : " CUSTOM 24"X 2T'TABLE HIGH T2 CUSTOM EXTERIOR TABLE T4 FURNITURE AND EQUIPMENT PLAN FURNITURE AND _ EQUIPMENT PLAN 36" DIA. CUSTOM ROUND HIGH TABLE T5 SCALE: 1/4"=1 '-0" NOTES: (1) ALL CUSTOM EQUIPMENT SHALL BE APPROVED BY NSF. (21 Al 1 FOIJIPMFNT SHAI 1 RF APPROVFI) RY AGA. Ill AND NSF IF APPI IFD. (3)Al I FOUIPMFNT SHAI I MFFT I OCAI GOVFRNMNFT CODE. ;, . • 8,-4„ • . • III • ... • ••• • _- — __ 2'-10"__-------.,__ _____--2_-- -_ ^ FINISH WALL = I oo SIDE ,, ;0 /;----- 1 : -.'.- - - SPLASH , ,,. z - - -- 1(k noczY V _____. .... _ ' ID ,,, _ _. ,t. 1 d- ^ / 01 ,. rc CO oO / � � � � COLUMN , _ BELOW p p / o / Fr 5� CHINE 4,-2» 9„ 2'-2" ° PANDA EXPRESS INC. T CORE DRILLED TABLE BEVERAGE COUNTER PLAN N / 1683 Walnut Grove Ave. 1/2"=1'-0" / Rosemead, California 91770 - Telephone: 626.799.9898 00/ . Facsimile: 626.372.8288 a i>.,... '��' CERAMIC TILE- - / \ / ',,, W/ 3/8" RADIUS COVE BASE ° < �< FLOOR SINK NOTE: ' G.C. TO C 0 0 D I NATE WITH PANDA FOR CORE DRILL LOCATION AO ideas, designs, arrangement and pions indicated N / � or represented Inc.y this drawing are the property of . . - Panda Express I and were created for use on �/ \f this specific project. None of these ideas, designs, SECTION A arrangements or plans may used or disclosed to any person, firm, or corporation without the --------- ( written permission of Panda Express Inc. 1 1/2"=1'-0" 410 1/2".i'-o"FRONT ELEVATION .1- GRANITE TABLE TOP REVISIONS: 3,_61, „ A ----- __ ---_ - -, 2'-8" 2'-10" , W -• 3"s COLUMN » 1" W —J COLUMN, —_ _ _ _ 1 __2'-8'' � 1 6 1/2" Q CAST IRON BASE n OPENING '- _ A o \- O� Z z li Iiill! 11:l1 ; jj(I� jii:ui ill! Z I�.;I�it;;�!I i;'i �+:f I, ;il{ j _ C? 5 w iii if C'Illil ,I lltiiillj; ij;i�ii 1 II ;Ili{{i i! �'i;;l;I '+ i i I _ L_ o o ii<<ti?:i t!iilii�i� =-=l i,.!,ii il�fifl�lfli vL_ 0" o" ° ^ 6 . tw, N 1 ;- 5" �r K, 2'-7 1/2" PAN WIDTH I I ISSUE DATE: 3" » SECTION i 1 CORE DRILL 3 1/2" 3 PLAN �-- 1ST PERMIT APPLICATION 01/09/09 3 1/2" SIDE: ELEVATION SIDE ELEVATION DRAI\ PAN DETAIL 3ND 0 0 3RD 1/2"=1'-0" 1/2"=1'-0" 1/2"=1'-O" CORE DRILLED TABL- SECTIO \I 4TH 5TH PROVIDED BY PANDA BEVERAGE COUNTER DETAIL PROVIDED BY PANDA STANDARD TABLE DETAIL 6TH INSTALLED BY G.C. F2 INSTALLED BY G.C. Ti - T4 SCALE: 1"=11-0" c --- DRAWN BY: SAR 2'-6" F10-F507 08/22/07 3" 1 �11. NOTES: MATERIAL SPECIFICATIONS COLUMN - SEATING PANDA PROJECT#: S4-09-D2116 _ BELOW :+,' _ _ CASEWORK CONTRACTOR TO PROVIDE THE FOLLOWING: A. FORMICA 5165-15 QULITED BRASS LAMINATE ARCH PROJECT#: 0821 �' 1. WHITE MELAMINE FINISH FOR ALL EXPOSED NO. ITEM MODEL # and�IANUFACTURE DIMENSIONS WOOD and FINISH MATERIALS B. SOLID SURFACE COUNTER TOP W x D x H (0 x H) I PARTITIONS, SHELVES & PANELS FOR INTERIOR GRANITE: TBD = OF SERVICE COUNTER C-1 CHAIR 189-UPS MTS 15 1/2»x18 1/2" MAPLE W/CHERRY STAIN VINYL: MTS PROVIDED NAVY BLUE \:1:,t �+ C. REVEALS: TBD 18 " SEAT HT (BACK) COLOR: CY17 NAVY ISA 2. BRUSH CHROME STATION PULLS & PIANO HINGES » 1/2" / ARCHITECT: I D. BASE: T-61c C-2 STOOL 187-30 MTS 15 1/2 x18 1/2 MAPLE W/CHERRY STAIN VINYL: MIS PROVIDED NAVY BLUE EUROPEAN HINGES FOR DRINK COUNTER (NO 30" SEAT HT (BACK) COLOR: CY17 NAVY ISA PULLS) C-3 SET 1 EE CUSTOM CUSTOM TNT, DESIGN SEE DRAWINGS N/A VINYL: NAUGAHYDE, PAl TERN: "SPIRIT Mil I FNIUM" LOCK FOR ALL CABINET DOORS AS SHOWN BACK / SEAT: US-370 PAPRIKA R P G ..., - 3. WHITE PLASTIC VENT ON DOORS FOR MANAGER C4 EXTERIOR CHAIRS 400.1 CUSTOM BY RICHFlELDS 15 1/2"x18 1/2" N/A CABINET AS SHOWN, APPROX. SIZE: 4"X10" 18 " SEAT HT SIRTAKI CHAIR - COLOR ANTHRACITE BETTER DESIGN GROUP 2'-0" 3'-0» ARCHITECTS, INC. 4. OPENINGS THRU DRINK COUNTER TOP FOR PIPES 24 X 32 TABLE AND DRAIN PAN PER OWNER PROVIDED DRAWINGS - 7965 O CIRRUS DRIVE 36" R O L [\D TABLE AND MANUFACTURER'S CUT SHEET TOP DIMS. TOP MATERIAL COLUMN SPIDER BASE (FINISH: BLACK WRINKLE) BEA 574-3036 ,OREGON 97008 NO. ITEM MANUF. L x W x H (503)574-3036 FAX(503) 574-2916 DATA CONDUIT. 5. OPENINGS THRU REAR COUNTER PARTITION FOR , 4'-0" L, (SEE SECTION FOR DETAIL) /4" UBA TUBA GRANITE ON MAPLE 3" DIA. BLACK ELECTRICAL ( ) Ti T1 21" X 24" TABLE CUSTOM 21"x24"x30 H" -- CORE DRILL 4" INTO CONCRETE WOOD SUB TOP CAST IRON r T2 24" X 27" TABLE CUSTOM 24"x27"x42H" 3/4" UBA TUBA GRANITE ON MAPLE 3" DIA. BLACK -- CORE DRILL 4" INTO CONCRLIL STAMP: WOOD SUB TOP CAST IRON 18" WIDE x ? " 3" DIA. BLACK __ " � 2'-6" T3 COUNTER TABLE CUSTOM 3/4 ?JB GRANITE ON MAPLE CORE DRILL 4 INTO CONCRETE EE NS) WOOD S TOP CAST IRON (-1-) (4-) ° T4 EXTERIOR TABLES CUSTOM SEE DRAWING BLACK METAL TOP VI/UMBRELLA HOLE N/A N/A PER MANUF. (SEE DWGS FOR BOOTH & Sk l I EE MODULES) AND BLACK METAL BASE PO ND, OREGON 4, --, 36" 42H" 3/4" 3" DIA. BLACK " ��� 2520 A09161 T5 36" DIA. HIGH TABLE CUSTOM 36 DIA. x 42N 3/4 UBA TUBA GRANITE ON MAPLE -- CORE DRILL 4 INTO CONCRETE ,� WOOD SUB TOP CAST IRON 1? OF 6'N>N-r ISA T6 48" X 24" ACCESSIBLE CUSTOM 48x24 x30 3/4" UBA TUBA GRANITE ON MAPLE 3" DIA. BLACK CORE DRILL 4" INTO CONCRLIL < - N, TABLE WOOD SUB TOP CAST IRON (2) Q, - 24 X 48 TABLE PLAIN BACK STYLE < VINYL UPHOLSTERED --------o PANDA EXPRESS 2'-6" BOLTAFLEX #364020 cs. color: AUTUMN GENERAL TIGARD TOWN SQUARE : -, 1,...1.) v NO. ITEM MODEL # & MANUFACTURE DIMENSIONS MATERIALS �� ► 16230 PACIFIC HWY. SUITE 100 LI VINYL UPHOLSTERED M F1 SERVICE COON TER CUSTOM SEE DRAWINGS TOP: GRANITE, BLACK GALAXY "GR-61" AND TILED COVE BASE "T-61B" 6"X 12", TIGARD, OREGON o .. <- BOLTAFLEX #364028 > FACE: PLASTIC LAMINATE "OCTOPUS", COLOR: 585, PREFINISHED 0 ,-E; ;M; = color: MALT �, ir, F2 BEVERAGE COUNTER CUSTOM SEE DETAILS THIS SHEET TOP: GRANITE SLAB, COLOR: COAST GREEN, o ISA i CABINET : PIONITE, CARAMEL CREPE, ATM, SUEDE, W/I-61 B COVED BASE U ^ BLACK VINYL BASE F3 TRASH RECEPTACLE CUSTOM BY RICHFIELDS 21 1/2" x 21 1/2" FIBERGLASS TO MATCH FORMICA #7202-58 "BRICK" `s' < ON 3/4" PLYWOOD > 39" HIGH WITH S.S. TRAY RAILS F 11111111111111 1 * 0 - 24" X 36" TABLE O Lel PROVIDED BY PANDA CASEWORK/COUNTER CV INSTALLED BY G.C. AD A TABLE D=TAIL Ti - T4 STANDARD BOOTH/SETTEE - ELEVATIONS C3 . SCALE: 1"=1'-0" SCALE: 1"=1'-0" _ _ _ _ .. _ _ . • • •••• a CNRAL R011S : . . . • . . . . 1. VERIFY ALL HVAC & KITCHEN EQUIPMENT PRIOR TO ROUGH IN, S3-00-00 03/18/05 �'''"! PROTECT EXISTING A/C UNIT ON ROOF AND CONNECT TO NEW PANEL E _ - A•01.‘ AS SHOWN ON ROOF PLAN. ELECTRICAL DESCRIPTION 2, FROM MANAGER R M vl NA R / - COMPUTER DATA LINE: ROUTE 1" CONDUIT 0 A GE D DIRECT CONNECTION • 0 OWNER(PANDA EXPRESS, INC.) S SERVING AREA (©24") TO CASH REGISTER (©24") W/4 CAT. 5E CABLE $ 4 RJ45 JACK __ r�"'� C CONVENIENT OUTLET GC GENERAL CONTRACTOR K KITCHEN 7/7 - •'AT MGR STATION & CASH REGISTER. n' -A.- _ rn 0 3.PHONE LINE: PULLPHONE WIRE & INSTALL PHONE JACK FOR MAIN PHONE FS FLOOR STUB OUT EC ELECTRICAL CONTRACTOR (E) EXISTING M �i• FOR SIGN. IELD r J � • � Q • LINE (MANAGER STATION AT 48" & 96", CASH REGISTER 24") FAX LINE DC DROPPED CORD KEC KITCHEN EQUIPMENT CONTRACTOR FOR N. FJ E ON ® `r (MANAGER STATION AT 24") CREDIT CARD LINE (CASH REGISTER 24") 0 4 444> a 4.POWER SUPPLY FOR COMPUTER, CASH REGISTER (81, & 86, OR 87A, & 81) CONNECTION LOAD PHASE H.P. VOLTS REMARKS DIMENSIONS MANUFACTURE MODEL# EQUIPMENT NO. G Q SHOULD BE ON THE SAME CIRCUIT BREAKER, W/ISOLATED GROUND & R.I.H. TYPE WATT W x D x H x H _ a I�! ORANGE RECEPTACLE. I { ) T CHN��' I SERVINGAREAEQUIPMENT 4B < EY N 0 T E s : 24" F 1500W 1 ■ 115 SEE DETAIL SEE PLAN KEC CUSTOM SNEEZE GUARD 2 J 24" F 3600W 3 208 43 1/2"x23 1/21 APW HFW-3 3 PAN FOOD WARMER 3C j1 j i -- GFCI F3-.36 PANDA RESTAURANT GROUP INC. O1 STAINLESS STEEL PANEL WITH OUTLETS. 24" F 4800W 3 208 57 3/4"x23 1/2" APW HFW-4 4-PAN FOOD WARMER(2) 3D PANEL A & B C +96' �� ' SEE DETAIL / -�-GFCI I 1683 Walnut Grove Ave. • 16" C 1.5A 1 115 W/UD DISPENSER 30"x30"x35" CORNEUUS ED-2000 BEVERAGE DISPENSER 4AB Rosemead, California �� / A_14 A-19 •�.a I A-39 91770 2 ALL CONDUIT TO BE ROUTED IN CASEWORK 96" C 7.2A 1 115 ON S/S SHELF 15 x11"X16 CORNEUUS CARBONATOR 4B ,�� �"9 P-1 -"', I� WH_1 2 t I - Telephone: 626.799.9898 FOR FRONT LINE EQUIPMENT TO WALL. 32" D 7.8A 1 115 ICE BIN: S-420 22'X 34'x 76.5' MANITOWOC 0Y-0424A 400 LBS.ICE MACHINE 10J , -t-.; CANCEL IN WALL TO ABOVE CEILING AND 84" C 1.1A 1 115 --- 22'x 14'X 26.5* MANITOWOC IB-0824YC 800 LBS.ICE MACHINE 10K GFCI I _ Facsimile: 626.372.8288 CONTINUE TO PANEL. 6" D 11.7A 1 208/230 ON ROOF 34'X 24.13'X 25.75' MANITOWOC CVD-0875 _REMOTE CONDENSER 10Kc 3O ROUTE VIA 10 POLE LIGHTING CONTACTOR, CONTROL WITH SWITCH "z" .,, T ....--) I<ITCH TN EQU I PM ENT 4O MOUNT BOTTOM OF CABINET AT +7-0 AFF. MOUNT HOOD LIGHTS AND FAN SWITCHES AT +48"AFF. SEE HOOD CONTROL DIAGRAM 30" C 1 1 15 15 1/2"x341/2'(EACH) FRYMASTER MJ45 FRYER(2) 21D ROUTE FEEDERS TO EXISTING SHELL DISTRIBUTION EQUIPMENT APPROXIMATELY I All idas, designs, arrangement and plans indicated or r represented by this drawing are the property of 90' SOUTH OF DEMISING WALL. FIELD Panda Express Inc. and were created for use on �'�'� 30" C 11A 1 115 35.5'°(30.4"X32.75' RATIONAL CPC 61 GAS COMB!OVEN 24E VERIFY AND COORDINATE EXACT ( B-19 this specific dent project. may be these used by ideas,designs, % REFER TO DETAILS 2, 3, AND 4 ON SHEET E3 FOR WIRING 130" D 500W 1 1 115/20$ SEE PLAN KEC CUSTOM WALK-IN COOLER UNIT 31 REQUIREMENTS WITH SHELL CONTRACTOR. i GFCI to any person, firm, or corporation without the DIAGRAMS. PROVIDE SEALS AND EXPANSION COUPLINGS ON ALL written permission of Panda Express Inc_z- 0 CONDUITS ENTERING OR LEAVING IN DIFFERENCE TEMPERATURE. -3.0 -3.0 -3.0 130" D 500W 1 1.5 115/208 SEE PLAN KEC CUSTOM WALK-IN FREEZER UNIT 32 REFER TO ONE-LINE ON SHEET E4. o ') 0 - FS C 8.5A 1 1/3 115 SELF CONTAINED 27"(30"X36" RANDELL 9404F 27"WORKTOP FREEZER 32G diAl. _ - 6Q SWITCH FOR WATER PUMP FOR MAKE UP AIR UNIT ON ROOF FS C 12A 1 1/2 115 SELF CONTAINED 8433"x35" RANDELL 9050K-7 84"REF.PREP.TABLE 34A q-.i_. -. I GFC + ' - t$ A-38W A-41 ' - 48"REF.PREP.TABLE L B 3 O 7 FS C 9A 1 1/3 115 SELF CONTAINED 48 x33 x35 RANDELL 9030K 7 ( ) 34D B- CIJ - T- BANK $y REVISIONS: O PROVIDE (2) 1 CONDUIT IN LOW WALL FROM MANAGER. STATION TO CASH REGISTER. IN ONE CONDUIT, RUN (4) CAT 5E CABLES AND FINISH WITH 4 50" C 1 1/3 115 12 1/21x21" GENERAL GSM-1/66 FOOD PROCESSOR 45A +7 -21 RJ-45 JACKS AT EACH END, LABELED Fl, F2, F3, AND F4. 50" C 1 1/2 115 71/2'x81/2'X20' VITAMIX #748 BLENDER 46A a , +132 B 120 l __ B 8 AIM ' B-40,42 SEE MGR STATION ELEVATION ON THIS SHEET -1.o MALL EQUIPMENT ■► 17 1 1 sl I o CO A 24" C 100W 1 115 ON S.S.COUNTER 160 AROMA ARS-1055S RICE WARMER 54 L iii 8k o ' 0 ��� Ti I 9� SURFACE MOUNT ON FREEZER BOX PER CODE _ ( 15 ! �� O e 411 DC 1600W 1 208 PLUG:NEMA 6 15R 201/8"(131/4'X181/2' SHARP R-23GT MICROWAVE(2) 55 +99 +50 +84 +24 OD A-21,23,25 FOR SI FIELD 10 ANSUL PULL STATION REFER TO DETAIL THIS SHEET. 0 ' B-37,39 + �� VIA SW $z FOR 4CATION P OS E QUIPMENT 4$t> 11 POWER FOR LIGHT, FAN & DOOR HEATER AM 24' C 500W 1 115 CUSTOM 11 1/414 1/21x9* RESNOS S 460 CASH REGISTER SYSTEM(2) 81 ,,+132 5 5 SEE LIGHT & DOOR HEATER WIRING DIAGRAM ON 50" C 100W 1 115 SEE DETAIL CUSTOM COMPUTER 83A • • SEE EVAPORATOR COIL WIRING DIAGRAM ON 24' C 50W 1 115 SEE PLAN POS PRINTERS(2) 86A B-33 35 ME. 'MEM 4AB 50" J ISSUE DATE: 1c�7 - 2 O13 WALL MOUNTED SHOW WINDOW OUTLET `�� S0 C 50W 1 1 1 5 FAX 87 1 1 1 1 1 1 L HOT TEA DISPENSER 6" 1 1ST PERMIT APPLICATION: 1/09/09 AT 6 BELOW CEILING. J MEP EQUIPMENT 44z, 2ND O14 FIELD VERIFY J-BOX LOCATION FOR SIGN, CONTRACTOR TO B " 0 +,-* +111 { 132 D 1000W • 115 SEE MECH.DWG. SEE PLAN CAPTIVE AIR CUSTOM EXHAUST HOOD M1 PULL BOX a i I 3RD PROVIDE LIGHTING CONTROL CONTACT AND TIMER �� � 4TH • PROVIDE DEDICATE NEUTRAL FOR ALL SIGNS _ SEE MECH.DWG. 12"X 6"X 18" CAPTIVE AIR CUSTOM HOOD CONTROL PANEL M4 - I I SEE MECH.DWG 24"x24" CAPTIVE AIR FIRE SUPPRESSION SYSTEM M6 B 10,12,'34,36 5TH 8::. PROVIDE CONTACTOR TO SHUNT CIRCUIT FROM FIRE SUPPRESSION 88" C 5.1A 1 1/2 115 36 1X 11 1/4"X14" MARS 36 N FLY FAN M8 401 • a rte ,. 6TH SYSTEM. 30" C 115 SEE PLUMBING DWG GAS WATER HEATER P2 tr_ + " - _ ICI ! !ME / �i iiina ` -T- OSEE17 EVAPORATOR I WIRING DIAGRAM ON 84" C 100W 1 115 IN S.S.COUNTER SEE PLAN MUSIC EQUIPMENT/SHELF E1A B 28 � �,II jIV I- COIL �� " �--- --�i 44 J-BOX 50W 1 115 SEE PLAN DOOR BELL E3 / ��18 ROUTE VIA 2 POLE CONTACTOR, CONTROLLED BY SWITCH "y" Mil lati , HIGH HIGH u • W/DOME BASE SEE PLAN PANASONIC M-336 CCD SECURITY CAMERA E4A 1/2HP _G....:.,. " / �.�.,., (FUTURE I ,� 41 DRAWN BY: SGW L--)19 DISCONNECTING MEANS, PROVIDED BY MANUFACTURER, REQUIRED FOR EACH 84" C 50W 1 115 W/EMI LOCK SEE PLAN TOSHIBA(TIME LAPSE) SECURITY VCR E4B it 0 GFCI.Iii B-22 O SYSTEM MEANS RE UIRED TO �� � SIGN AND OUTLINE LIGHTING S STEM Q BE READILY ACCESSIBLE, OR CAPABLE OF BEING LOCKED IN OPEN POSITION 84" C 50W 1 115 SEE PLAN 14.3a x 14.2 x 12.6 PANASONIC CT-13R17B SECURITY MONITOR E4C { O 'l - <>Ole"I I {AS NOT WITHIN SIGHT. MUST COMPLY WITH ART. 600.6 GROUNDING OF SIGNS SEE ELEC. DWG ELECTRICAL PANEL E7 sir, �, _ '►'fit; 40 �+ �"^' V A SW i AND METAL EQUIPMENT MUST COMPLY WITH ART. 600.7. BRANCH CIRCUIT I __- / 1 ►„RATINGS MUST COMPLY WITH ART. 600.5.8. BANK � � L PANDA PROJECT#: S4-09-D2116 I �NAGE 0 • CONNECT HEAT TRACE FOR FREEZER CONDENSATE DRAIN. VERIFY D 20A 1 115 SEE SIGN DWG DETAIL CUSTOM I.D.SIGN S1 0 5 , 1�� 1 B-2,4,6,25 �. r PROJECT#: 0821 / RDG0809 4110 Q �� HIGH HIGH _ 0 21 PROVIDE 120V CONNECTION TO TIMECLOCK PROVIDED BY DIVISION 15. ROUTE VERIFY D 200W 1 115 SEE SIGN DWG DETAIL CUSTOM LOGO S2 •ajr;wRECIRCULATION PUMP VIA TIMECLOCK. VERIFY D 500W 1 1 15 SEE SIGN DWG DETAIL CUSTOM MENU BOARD S6" I ' ESL, B-7,9,11, 0 .99 D 500W 1 115 SEE SIGN DWG DETAIL CUSTOM BEVERAGE SIGN S7 0 o { ARCHITECT .iiiii, l 0 llI EEC RICOPERATED GAS 1FaI!I � iij ALVE FOR FUEL SHUTDOWN A• RPG -.1* "B" N SERIES COMBINATION 65KAIG � ± � , �-�- JJJ4OII EQuI ED ELY U.M.C. PROVIDE J BOX WITH CONDUIT PANEL ( ) 1 •O N N ECTI O N TO ABOVE CEIUNG BY G.C. �� r //L/ l BEATER DESIGN GROUP ir--- SPEAKER WIRES INSTAU_ED 120/208V VOLTS 4 WIRE TYPE -- MAIN BKR. SIZE � 11 is BY OWNER'S VENDOR B-14,25 ARCHITECTS, INC. CAMERA WIRES INSTALLED 3 PHASE 400A BUS AMPS FLUSH MOUNTING 400A MAIN LUG SIZE I �, ' a`""' €) BY OWNER'S VENDOR LOAD (VA) lo UM ABOVE 1��) - • �•� �� 111! 7965 SW CIRRUS DRIVE LOAD (VA ( ) ,,._ 'p7 " / TO PHONE BOARD - _ � �� REMARKS LTG REC MISC BKR CIR CIR BKR MiSC REC LTG REMARKS 4WD Q '�- ��rV1+� CIS BEAVERTON,OREGON 97008 MUZAK SYSTEM OA (DB t�C OA m6 OC 8 4 =1 1{ ta�l / ►� {503 574-3036 FAX(503) 574-2916 SECURITY SUSTEM • M4 3 8 767 1 2 2 20 1 1200 t +'241 i`.+►��:-�-O Q 1 2 Sc 3 PAN FOOD C1 � "1 ,1 __ 1200 t E4B I �,�� � wow/1w. B-13,15,17 CREDIT CARD UNE& 1 1196 1 3 4 WARMER 0 1 4 ,sfrSEGURITY LI __ 1 ��� I �� - '�-vGR 2� SNEEZE GUARD 3000 2 5 6 3 1200 Q = y B 1,5 { , �, 14 O�T ..,.�..- IN$IOES.SS SHELF 4 PAN FOOD 1600 1 ji 8 ;9i#1 1500 HOT TEA DISPENSER ___s. �� ° ° HIGH , _p» I STAMP: WARMER 1600 -- 9 10 t 1035 Q O TRAY POCKET �p PROF SECURITY LOCK 1 .! �, %� ill "��"' �� FS___ =- = 0 11 II 12 , 1380 .0 �� ��G1NEE1' `siv 13 . g, 14 2 200 HIGH �' 18197 AL) 1 I- ORANGE OUTLET W/ 3D 4 PAN FOOD 1600 0 ISOLATED GROUND © 1600 -- 15 16 v 1 , 1107 ta Q FOR COMPUTER WARMER 1� 20 55 1 ��1 '+ 17 „ 18 t 800 Q � , 1 <>-(\i OREGON lsk ° El __VOICE(FOR BUSINESS UNE) O 828 ' 19 20 2 800 o FAx 3P< 3 1 7 t I I • I It A-27,29,31 OF 4'C Ali 0�!` 500 21 22 32 ®a 0 - VIA SW $z oyy • 6, 1 � ORANGE OUTLET W/ t 23 „ 24 20 1 1217 OK ICEMAKER A-37 FRANK RO ISOLATED GROUND ���-. FOR COMPUTER 81 a 4A 730 6 25 26 2 -- 1217 CONDENSING itl> , ''t ' ` t3 13 � { EXPIRES 12/31/10 I v) 0 AC-2 (28.9A) (N) 3468 27 „ 28 2 1 2 400 11i. ' 'i' 'i•3/4 CONDUIT FOR TEL :��� . - TO FRONT COUNTER 0 3468 -- 29 „ 30 1 1500 Q SNEEZE GUARD II I I - : I - - ' I I )--1- -1.CONDUIT FOR DATA 0 3468 -- 31 a, 32 1 1200 COOLER& FREEZER O TO FRONT COUNTER 31 COMP. 920 1 33 ,I 34 1 , 978 2a i 920 -- 35 36 6 1380 PANDA EXPRESS 1•4614t STATION ELEVATION ON Q COMP. 1150 1 37 „ 38 3 360 RECEPTACLES a 1150 -- 39 � 40 20 1 800 d 0 FOR SIGN. FIELD TIGARD TOWN SQUARE • S HOOD LIGHT _ 1000 1 �''� 41 � 42 2 -- 800 0 VERIFY LOCATION 3/4" DIA. CONDUIT-ONLY, PROVIDED AND TOTAL 101431043412088 6657 7892 7977 TOTAL �����'j INSTALLED BY ELECTRICAL CONTRACTOR. TOTAL CONNECTED WATTS 55191 FACTOR DEMAND • 1 fi230 PACIFIC HWY. SUITE 100 ACC CONDUIT, INSIDE SPA SPACE TO ABOVE A/C OR HEATING WATTS 10404 Q 1.00 10404 LOCK ON DEVICE OF BREAKER SERVICES. 2'" TIGARD, OREGON PROVIDE 4" OCTAGONAL JUNCTION BOX WITH KITCHEN EQUIPMENT p 26000 0.65 16900 D KITCHEN EQUIPMENT ,r'�- LIGHTING LCL 0 1.25 0 Q LARGEST MOTOR INCLUDED -, SCREW THREADS SET AT THE 2 & 8 O'CLOCK#-:'.., POSITIONS REMAINDER 18787 1.00 18787 -i e ki-?, \� � J �---� J-BOX PROVIDED BY u.: --...(e TOTAL DEMAND WATTS 46091 Ct TOTAL DEMAND AMPS. 120 _ M NC R CIAN. F. a - FLANGE CONDUIT REMOTE FIRE PULL STATION. CABLE, AND ANY � - � co OTHER MISCELLANEOUS EQUIPMENT SHALL BE BOLT TO F.F. El . 0 PROVIDED BY OTHERS _. - ..t_.__ U Li- S.S. 1-5/8" DIA. SYSTEM POWER PLAN., - ., . TUBE. COREDRILL 6" DESIGN POWER PLAN ANSUL PULL. STATION 1 3 t�`" INTO FINISH FLOOR. 1 CONSULTANTS tic. El .Q 1/4" = 1 --0 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 5.5. OUTLET PANEL vETAIL ( � ) 503-248-0227 FAx 248-0240 NTS L--' CONTACT: STEVE WATKINS ww 11.0• ww • • w w • • •w w • ® A , (ON: 7......„....„* / • • - \\(,P 2007 LIGHTING t� Q w LIGHTING FIXTURE SCHEDULE PROVIDED FOR INFORMATION ONLY. VERIFY AND INSTALL PER ELECTRICAL DRAWING ISSUED 5/1/07 113E4 } , I:�. 0 0 ) (i) ITH� SYMBOL DESCRIPTION QTY. MFR. & CAT. NO. LAMPS X WATTS REMARK I V.) ® • � Q KITCHEN LIGHTING I ( G O T-BAR CEILING RECESS MOUNTED KITCHEN CEILING LIGHTS. t,_ 4< ;8) LIGHTOLIER 120V WITH ONE ELECTRONIC BALLASTS 8 D830 AND T-8 LAMPS. EXTRUDED VIRGIN LENS. XP2GVA332-UNV-SO 3x32W BAKED-ON WHITE ENAMEL FINISH. / T-BAR CEILING RECESS MOUNTED LIGHTOLIER T8 KITCHEN CEILING PANDA RESTAURANT GROUP INC. l� FLUORESCENT LIGHTING FIXTURE,2'x4', FIXTURE: D830 NIGHT LIGHTS. � � 120V WITH TWO ELECTRONIC BALLASTS AND 2 XP2GVA3321200-12003 3x32W FURNISHED BY OWNER " ���=■�■1 =���o4allbo. ���■� � � `_—=--� �_� '' T-8 LAMPS. EXTRUDED VIRGIN j''''k L4�' MI �""' n L7� 1 1583 Walnut Grove Ave. LENS. BAKED-ON WHITE ENAMEL FINISH. MN u 111 Ro semead, California A-- 7 91770 AM EMERGENCY LIGHT,DUAL HEAD 3 LIGHTOLIER E1-25NH-12W 2X12 WATT HALOGEN LAMPS SUPPLIED W/FIXTURE T ® WITH BATTERY PACK, 120V,WHITE COLOR uI Telephone: 626.799.9898 Facsimile: 626.372.8288 A UNIVERSAL MOUNT EXIT SIGN, LIGHTOLIER FIXTURE SUPPLIED W/ FURNISHED BY OWNER I ■■�1� ■- ■- L72 LED LIGHTED, 120V WITH BATTERY PACK, 2 FIXTURE: LUNW2G (DOUBLE FACE) LED LIGHTING t 2 FACE, GREEN LETTER FIXTURE: LUNW1 G (SINGLE FACE) rilluipl 0 FURNISHED&INSTALLED SYLVAMIA CF30EL ELECTRICAIGONTRACTOR ,iv' HOOD LIGHT, INCANDESCENT, 120V 10 BYE IPMENT PPLYER TWIST 3000 K LAMP TO DO THE WIRING ti...��rWl ,'o'' ! o a , 9 9 EQUIPMENT SUPPLYER �_�I 1 , t �. I P Y 9 property�_�■■����� �' All ideas. designs, arrangement and plans indicated Ij or represented b this drawing are the ro of Panda Express Inc. and were created for use on FURNISHED BY �•' h this specific project. None of these ideas, designs, 6B WALK-IN COOLER FLUORESCENT LIGHT FIXTURE, FURNISHED&INSTALLED T8 D830 ( r arrangements or plans may be used by or disclosed ' ! s3� 8"W X 4L' 2 BY EQUIPMENT SUPPLYER 2x32W OWNER to any person, firm, or corporation without the written permission of Panda Express Inc_ „ L71 DINING AND BATHROOM LIGHTING . 0 =NM I ill A-`3 Lam, FLUORESCENT WALL MOUNTED FIXTURE 2 LIGHTOLIER SYLVANIA DULUX ULU VIA '�.a ';.b '�.� � FT40D/830RS CENTER OVER MIRROR IN 1�1 1< t ) CENTER ABOVE MIRROR IN BOTH RESTROOMS ALTER QVW8SPFOS2FT-120-BR (2 PER FIXTURE) BOTH TOILET ROOMS i 111 i m Iiik � I � REVISIONS: CEILING MOUNTED LIGHT,FLUORESCENT LIGHTOLIER:ALTER WINDOWS WALL 2-SYLVANIA 18W TRIPLE FURNISHED BY OWNER ( SEE El _ BELOW \ 0 L� T 3 TUBE DULUX QUAD BASE MY t I -- 120V, 13"SQUARE,WHITE FIXTURE: QVW1 SPASQ2QT12OF4 CF18DT/E IN 830 1 L6B 0 (`_ - ,\ • 1 hs, Am LIGHTOLIER SYLVANIA 37W IR FREE STANDING DINING LIGHTING W 1.�l C� MY ® ALCYON GLASS RING MR16 TRACK HEAD 27 22GR6WH AND MP MONOPOINT POWER FEED MR16 FL35(OR EQ.) ACCENT LIGHTING(�i END CAPS ' k 2') �'N. i 4n'IN L _ _ '" _ _ -I 413• ,�.� I i& A FFIT LIGHTOLIER: 2000LV W/2008 SYLVANIA 37W IR IN SOFFIT©SODA LINE ® •I 4 j (� DOWLIGHT, RECESSED IN GYP BD SO 14 SPECULAR CLEAR REFLECTOR MR16 FL35(OR EQ.) I = b V4 • �`�b ti„, SEE El ® -�r,, ,� Affil p DECOR LIGHT FOR CHINESE LANTERNS 10 SEA GULL LIGHTING 6905XBLE-962 SEAGULL 97102 SHORTEN CORD IN FIELD ■ �.:;._ 10, j �'�' ® O AND MP MONOPOINT POWER FEED 13W BI PIN BASE INSTALL W/O GLASS SHADE Afilk LIGHTOLIER: LYTECASTER 1004F18ES W/ SYLVANIA 18W TRIPLE END CAP ONLY I all t1 TUBE DULUX QUAD BASE DINING LIGHTING A- ■ ISSUE DATE: • 0 DOWLIGHT, IN CEILING TILE(END CAPS ONLY) 26 1008 BRUSHED GOLD REFLECTOR TUB DT/E IN 830 VIA A 1 O ■ { i ' �� L77 �� ' 1ST PERMIT APPLICATION: 1/09/09 © SINGLE CIRCUIT LOW VOLTAGE TRACK, WHITE JUNO TRAC 12/25 SERIES PROVIDED BY I OWNER I �/ .' d I \ 2ND Ai 0 WITH END F NN T A `v? _ 1 TS I FEED CONNECTOR OR 3RD AND REMOTE TRANSFORMER I I L741_, I L77 4TH LIGHTOLIER RECTANGULAR MONOPOINT POWER SUPPLY FOR L73 0 I a i t AEA In / a .� 5TH LIGHTOLIER 6170 WHEN REQ'D BY CODE s 10 FOR MTG TO OCTAGONAL OR ROUND J-BOXES 7 � NL j�”' T1 (2') sTH MP V4' 1IiIIII Ls�,r:� / � iiiIun EXTERIOR LIGHTING I ° -�� i J� i, 1..,.:.=��I •WUIII1"'. 601119=1 8 DECORATIVE AWNING LIGHTS SYLVANIA 32W TRIPLE SEE ELEVATION FOR Nis I �� / t,��j •`t73' �� .d 111,111�� 0 AD 200 32-CFL-US-GWT-LDS96-PG3-WL TUBE DULUX QUAD BASE �, L6A14% / -iG _ (,30 WP GOOSENECK' ARM CF32DT/E IN 830 LOCATION ►,. �--; / .. :lti■.�.urt'/ - DRAWN BY. SGW LIGHTING GENERAL NOTES ' (� �� '.. •� 11 am A HAVE ELECTRONIC BALLASTS WITH 20% OR - 1 1. ALL FLUORESCENT FIXTURES SHALL E ELEC - ----1111111�� N I. :: ...--� ... i ' 7 LESS THD. �; 111111140511 2. CONTRACTOR TO PROVIDE ALL REQUIRED HARDWARES, BRACKETS, LAMPS, TUBES, ...ETC. FORA COMPLETE INSTALLATION. i c� • 3. ALL LIGHTING FIXTURES SHALL BE PERMANENTLY ATTACHED TO THE CEILING PER -I ! �.� / .�U 'Q■flj� i t 73 � � d PANDA PROJECT#: S4-09-D2116 N.E.C. 410-16(C). •• / 1,r iiii.h+. L77 / PROJECT#: 0821 / RDG0809 IF 4. CONTRACTOR TO INSTALL ALL LIGHTING FIXTURES INCLUDING OWNER-FURNISHED FIXTURES. ° ill gm 5. ALL FIXTURE BALLASTS SHALL BE U.L. LISTED. N sf!. , / I �` a L77 i 6. LIGHTINGS AT FOOD AREA ARE AT LEAST 20 FOOT-CANDLES IN BRIGHTNESS AND ARE SHATTERPROOF OR HAVE SHATTERPROOF GUARDS. li e 661 IlliW I __��,�1 111 /• I moulamma I ARCHITECT . NOTE: to 1 — PROVIDE 4 VERTICAL WIRES __ i �l�rff j it. ,� _„._ .'`t � (ATTACHED TO MAIN RUNNERS) HANGER WIRE SEE DET.ABOVE / i�1 ■�r� , 1 / WITHIN 3"OF EACH CORNER n �; / nib ' P A rN RI S OMBINATION 65KAIC �, S'• L77 3 i� T OF EACH FIXTURE. PANEL (N) SERIES COMBINATION ■, 120/208V VOLTS 4 WIRE - TYPE -- MAIN BKR. SIZE L6Ar,� / In IGN O LATERAL BRACING SEE DET. ABOVE 3 400A BUS AMPS SURFACE MOUNTING 400A MAIN LUG SIZE ���' / / ., EITER DE IGN GROUP PHASE I ���� KEE i L77 1111 � R S LOAD(VA LOAD(VA) = giiran f....... �I ARCHITECTS, I N C. #8 GA. MIN HANGER WIRE co REMARKS } LTG REC MISC BKR CIR CIR BKR MISC REC LTG REMARKS I -� i .r.• / � I OPP. CORNER FOR FIXT. PHA PH B PH C PH A PH B PH C - ■_ 2t B 41 �■�■■�� _ A �, 7 ,✓ 7965 SW CIRRUS DRIVE WEIGHTINGLESS THAN 56 LBS. 2 NIGHT T 102 35 1 3471 AC-1 (28.9A)(N) 3 �;.:;,, N�,,,��• L74 III G --�}-Q EMER& G L 1 2 ( 0 '�� BEAVERTON,OREGON 97008 „ - i �i � ��M; �t� a (503)574-3036 FAX(503) 574-291b_ -I K) !iIE 501 ■ 4 - 347i 683 ■ 5 „II 6 -- 3471■ 7 „ 8 t -_ SPARE 2 309 9 10 RE ■ 1 1 Ns , 12 v I t,■t_ NIIJI INSTA LED Lit- -A �� ril 1_4� 4' -"L77 I SPARE ■ 13 14 1 828 4a STAMP: _ 2 SERVING LIGHT 287 15 16 ' SPARE A 9` p' 7 + 76 ‘117_,6 L S --I I-{2 KITCHEN&RESTRM LT 1054 ■ 17 „ 16 t HOOD - VIA $g i. ( i �� ��GINEF�, /* �' f L77 'L WATER HTR 200 19 �� 20 ' �,, CONTROL L 3 , N� _ ►, g - ' / 18197 l' LIGHT FIXTURE SEE "E" DWGS FOR SHOW WINDOW 1800 1 ■ 21 „ 22 1 , 793 EF--1 PANEL h 9 ���1►���0,,���„ .,it, �} C�� �) 1111111111lbth -I I1 _ ..11 10421 �► � 6 L70 SPECS. PROVIDE SCREWS OR CLIPS 1� I ■�r�._ , L7 & FASTEN FIXT.TO T-BAR 1800 1 ■ 23 „ 24 — 793 T1-�' ~ ' O1600 ■ „ 793 I ( !1 18� / _ � L73( •)/I' �C�L' 1°�°'h 1200 1 ■ 27 „ 28 ' 540 ROOF RECEPT. 111 i "� � /' y�FRANK R��'�, LIGHT FIXTURE DETAIL 1200 1 E 29 30 2 1200 31 Ij 32 2928 EF- /MA-1 I I EXRES 12/31/10 NEON UGHT 32FT 33 34 2928 • Irgramani r ■ - SPARE ■ 35 36 -- 2928 -- - _ _ -I F- CR�► SIGN 1200 ■ 37 �� 38 04/ 500 CZ:' SIGN II �—-.— � ..�� � I - it -I I- Ql€► SIGN 1200 • 39 �� 40 ,,'�i 500 , SIGN �, -IF- mom► SIGN 1200 ■ 41 �� 42 r: SPARE PANDA EXPRESS TOTAL 4687 5937 7137 8520 7692 7698 TOTAL �__ TOTAL CONNECTED WATTS 41671 FACTOR DEMAND • LOCK ON DEVICE OF BREAKER SERVICES. TIGARD TOWN SQUARE 7C OR HEATING WATTS 22082 1.00Q. 22082 0 KITCHEN EQUIPMENT KITCHEN EQUIPMENT (N/A) a 0.65 0 - © LIGHTING CONTINUE LOAD LIGHTING LCL © 3321 1.25 4151 REMAINDER 15240 1.00 15240 © LARGEST MOTOR INCLUDED 16230 PACIFIC HWY. SUITE 100 TOTAL DEMAND WATTS �_ 41473 IF-AUTOMATICALLY CONTROLLED. SEE A/E-2, TIGARD, OREGON TOTAL DEMAND AMPS. 116 A/E-5. B/E-5, C/E-5 _ LIGHTING KEY NOTES Q SWI TCH BANK FOR SWITCHES "a""b""c""d""e""f""g"h""i""x""y""z". PROVIDE DISTINCT LABELING FOR EACH SWITCH. E 2 ■ SYSTEM GENERAL NOTES DESIGN LIGHTING PLAN Am% CONSULTANTS NC. 1. ALL SWITCHES SHALL HAVE STAINLESS STEEL COVER PLATES IN KITCHEN E2.0 1/4" = 1'-0" 1515 SE WATER AVE, SUITE 400 AND UTILITY SPACES. SWITCHES IN DINING AREA SHALL HAVE COVER PORTUWO OREGON x7214 503-248-0227 FAX 248-0240 PLATE FINISH TO MATCH SURFACE FINISH, COORDINATE WITH ARCHITECTURAL. CONTACT: STEVE WATKINS • •• ® A - --.7.-- . - - Elc : . I _ _ ,AN■,5 ROOF EQUIPMENT NOTES: 40IP-' ---',\\ 'I _ _- v. :_ ,d)v, 230/208V. 60CY. 1 PH. 1. ALL ROOF MOUNTED EQUIPMENT SHALL BE IN NEMA-3R ENCLOSURES. 6 - - - _ - • \ i" 2. ALL CONDUIT RUNS SHOWN ON THE ROOF SHALL BE RUN BELOW THE TEMPERATURE WILL BE BELOW 30 C. • 0 0 • CEILING SPACE WHERE AMBIENT 230/208V FINAL CONNECTIONS TO THE ROOF • EQUIPMENT IS LIMITED TO 5'-0' OF ® Lt I L2 DIRECT SOLAR EXPOSURE. O O FUSED k-: 3. ALL ROOF RECEPTACLES SHALL BE GFI TYPE. I G �O DISCONNECT BY T G ' 'A 4. VERIFY ALL FUSE SIZES AND TYPES WITH THE AIR CONDITIONING 2!� ,� ELECTRICIAN I 1 \ EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. -� T C N ti�5 2P 30AS 5. REVIEW THE MECHANICAL PLANS FOR THE AIR CONDITIONING CONTROL I REQUIREMENTS AND SCOPE OF WORK PRIOR TO BIDDING AND INCLUDE �/ i� EFAC6NDENSING PANDA ALL COSTS IN BID. 6. VERIFY CONNECTION POINTS OF ALL HVAC EQUIPMENT PRIOR TO - RESTAURANT GROUP INC. UNIT INSTALLATION. PROVIDE CONTROL VOLTAGE CONNECTION TO DUCT MTD. SMOKE DETECTOR AS REQUIRED BY MECHANICAL DRAWINGM-2.0 1683 Walnut Grove Ave. HI-LO i Rosemead, California PRESSURE 7. SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF MECHANICAL 91770 CONTROL EQUIPMENT AND THERMOSTATS. PROVIDE RACEWAY SYSTEM FOR AI Telephone: 626.799.9898 (PRE-WIRED) ALL CONTROL WIRING AS REQUIRED BY MECHANICAL.DRAWING M-2.0 qv,. I �ir� Facsimile: 626.372.8288 0= G NOTES { 1PH 2O8V 1 HP I N N ING UNIT <>SEE WIRING DETAIL 1PH 208V 1.5HP 1PH 2O8V 11.7A designs, arrangement and plans indicated C 0 DES or ideas.1 Panda Express Inc. and were created for use on or represented by this drawing are the property of Alk @KITCHEN EXHAUST SYSTEM DIAGRAM PROPOSED LOCATION "'-~-- I this specific project. None of these ideas. designs, �! I ICE MAKER I arrangements or pions may be used by or disclosed FOR COMPRESSORS. 32 31 to any person, firm, or corporation without the O2 SEE WIRING DETAIL 11111k =IELD VERIFY LOCATION. I written permission of Panda Express Inc_ Iiipl APPROX. 620 LBS 2 _- TYPICAL FREEZER SINGLE. PHASE -37/39 --33/35 lieiT/26 120V-1PH WIRING DIAGRAM 2P-30AS-15AF 2P-30AS 1/6HP os.(w.P.) -15AF A-30 REVISIONS: INCOMING POWER A-2/4/6 2P-30AS-15AF DS.(W.P.) & 115V_60CY.1 PH. VAPOR PR 3P, 3 0 A S, I 3P, 30AS, 3P, 60AS, 3P, 60AS, 3/4 C 3#8 +#10GND DS.(W.P.) & - + UGHTBASE N.F. (W. P.) N.F. (W. P.) 35AF. (W. P.) 35AF. (W. P.)RED ROOFTOP ROOFTOP ROOFTOP ROOFTOP IA7, 7 SEE A\ YELLOW "i 7 , W I 4 (,viiir BLACK 3P--35AS-60AF V Ell I WHITE /r \ I O I DS.(W.P.) A-28 I RELEIF A � ! ��� %�� GFI e PORT 1111F/ © Illiri 1141r/HEATER --' ,_./ .. ,.•.- { i 3/4"C_4#12 3/4"C 3/4"C , DOOR HEATER { - 3#8 3#8 ISSUE DATE: PILOTS LIGHT +1 #10 G N D +1 #10 G N D I 1ST PERMIT APPLICATION: 1/09/09 SWITCH PROVIDE AC TO FIRE ALARM J-BOX CONTROLS AS I 28.9A(MCA)O I 2ND CONTROL PNL. REQUIRED 3RD AS REQUIRED j� 4TH A WIRING DIAGRAM //// "ft, ® ® ® ® . MAGNETIC STARTERS W/ FREEZER LTG & DOOR HEATER I G Z / p 5TH TO FCP , SEE MANUAL ON-OFF P.B.'S 2 8V-3PH 6TH A/E-4.0 AND PILOTS 1.5 HP fy - - 230/208V. 6OCY. 1 PH. TO RELAY FOR A-22/24/26 I -� • TIMER PARAGON 8345-20 SHUT OFF POWER CHEF-2 B -1,41 TO A-22/24/26 230 V. 230/208 V UNDER GAS VALVE "A"-32/34/36 "E"-27/29/31 VIA CONTROL PN 0 1.-- - SWITCHIN &� UNDER THE HOOD. SOLENOUDE L1 L2 3/4"C,3#8+1#1 OGND 1"C 3#8 +1#10GND ��� DRAWN BY: SGW Al I I _ ©MA-1/EF-1/EF-1 A-28 - I I - A M MA �' --G TO A-32/34/3: V N w I © I uIFUSED NNECT ANSUL FIRE CONTROL / T ' • 1 VIA CONTROL PNL 1 I SWITCH BY I \ f L © © CO Q _ ELECTRICIAN PANEL, FCP TO SHUT 2P-30AS-15AF DOWN MAKE UP AIR, NOTE: VERIFY "CAPTIVEAIRE CONTROL PANEL" .3/4"C 3#8 +#10GND 208V-3PH PANDA PROJECT#: S4-09-D2116 TURN OFF POWER AND DIAGRAM BEFORE BIDDING SEE E-4 5HP PROJECT#: 0821 / RDG0809 GAS UPON FIRE IN HOOD. n O c a Y tov: 1 W lV m 208V-3PH I ARCHITECT c. KITNXUST SYSTEM IARAH A 1.5 HP A-28 JUNCTION N. T. S. E-3.0 TO A-32/34/36 B-27/29/31 3 4 N • x 1 BOX ON COIL VIA CONTROL PNL 1"C 3#8 +#1 OGND RPG 1 230 V SOLENOIDS 12'230 v • z COIL&VALVE I GFI I REITER DESIGN GROUP crj HEATER CABLE a SPORLAN MODEL I W'P' ARCHITECTS, INC. ON COIL ' #MKC1 &E6S130) 4 I DRAIN UNE 7965 SW CIRRUS DRIV TEMPERATURE CONTROL FA BEAVERTON,OREGON 97008 (PENN MODEL A198BC-2 SIM (503) 574-3036 FAX(503) 574-2916_ LI 3P-35AS-60AF FREEZER EVAPORATOR COIL 3 DS.(W.P.) I I 1 15V. 60CY. 1 PH. I e 115V SUPPLY UNE 3PH 208V I STAMP:-a_ 28.9A(MCA) N pRO F� G •• � , tV WHITE I- -I TBEoRx MIo L • HOT •-'1 • c /F1G81N19E7 F ssi op 1"0"- gy,-------- WOMEN'S MEN'S i OREGON R=STRM LTS RFSTRM LTS I V o RED I I CIRCUIT --MI `moo F s, l�� �� tiN FRANK R4GI' '� RED A-25 EXHAUS FAN COIL �"' � � � )20:( EXPIRES 12/31/10 SERVICE . PILOT > EF o SWITCH N © 1 r _ _ J I I) +-D L_ - - --- � / LIGHT & � �- SWITCH TEMPERATURE kt(PENN MODEL • 12 POLE WALL �� I C T T PANDA EXPRESS D A19BBC-2) • SQUARE D SWITCH TYP. 115V SOLEN01 E -G aPV02 -- COIL&VALVE CIRCUIT OF 2) I TIGARD TOWN SQUARE (SPORLAN MODEL BLOWER FAN(S)MOTOR UGHT B-26 • HOT # MKC1 & E6S130) CV ' N . 16230 PACIFIC TIGARO, OREGON SUITE 100 COOLER EVAPORATOR COIL (11.7 NOTE: LIGHTING $ EXHAUST FAN CONTROL t?I AGRAII IB' \ 1. WIRING SHOULD BE DONE ACCORDING WITH NATIONAL AND LOCAL CODE. FOR RESTROOMS. N.T.S. E-3. 2. CHECK VOLTAGE ON CONDENSING UNIT AND EVAPORATOR • COIL BEFORE ANY WORK lS DONE. • 3. SOLID LINES TO BE WIRED BY LICENSED ELECTRICIAN ON SYSTEM SITE. DOTTED LINES ARE MANUFACTURE PRE--WIRED. DESIGN ROOF PLAN 4. ANY PENETRATIONS THROUGH BOX SHALL BE SEALED AIR CONSULTANTS tic. TIGHT. E3.0 1/4" = 1'-o" 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: STEVE WATKINS • • •• • •• . • • • • • • •• • • • • • • _ _... ELECTRICAL PREWIRE PACKAGE " NAME DATE 10/20/2004 NN GENERAL NOTES S YM B 0 LS AND NOTES DRAWING NUMBER 321110A0 JOB NUMBER DRAWN BY = CONTROL INPUT 120VAC H1=UNE, N1=NEUTRAL 3 Phase, W/ 2 Exhaust Fans, 1 - E )( DEPARTMENT REEW, AND TO SECURE THE NECESSARY CONSTRUCTION PERMIT ONLY. CONTRAC- • SHADED OUTLET INDICATE FIXTURE WITH 90 MINUTE BATTERY PACK 2 ci- iSA 15A BKR Supply Fan, 2 Relays w/ 2 -DPDT ( EMERGENCY LIGHT WITH 90 MINUTE BATTERY PACK t - on/off w/ Supply Fan, Exhaust THE ELECTRICAL DRAWINGS, SPECIFICATIONS ANC) GENERAL NOTES DESCRIBE THE RECOMMENDED on in fire condition SCOPE OF WORK AND THE DOCUMENTS SHALL BE USED FOR THE PRUPOSE OF BIDDING, BUILDINGS • - ag (Fan switch Shown Instono}IT ONLY. CONTRAC- SHADED OUTLET INDICATE FIXTURE WITH 90 MINUTE BATTERY PACK 2 Et a_ TOR SHALL PROVIDE CONSTRUCTION DRAWINGS AND OBTAIN WRITTEN APPROVAL OF ALL A1oA2 96 WH babel Description INSPECTION AUTHORIZED GOVERNMENTAL AGENCIES AND UTILITY COMPANIES PRIOR TO START ® SELF CONTAINED EXIT SIGN WITH 90 MINUTES BATTERY BACKUP, PROVIDE 3sT�-z a-2 ��.. LOW LEVEL EXIT SIGN AS REQUIRED BY FIRE DEPARTMENT OR U.B.C. '°"A "" s Starter ghte FS Fan Switch lr ) • OF AFFECTED WORK. R1 e%oSU��ST�Ansul/PyroChem) g 4 LS Light Switch Nur A. NOTES: 1. FIXTURE TYPE TO BE SELECTED BY ARCHITECT I. Hood Li ht(s} Q 2. CONTRACTOR SHALL PROVIDE CONSTRUCTION AND SHOP DRAWINGS BASED ON THESE DRAWINGS, GP General-Purpose Relay DPDT SPECIFICATIONS AND ADDITIONAL DESIGN CRITERIAS FURNISHED BY OWNER AND SUBMIT TO 2. FIXTURE SHALL HAVE MINIMUM 25 LUMENS/WATT EFFICIENCY REQUIRED 5 TX Transformer BY CALIFORNIA ENERGY COMMISSION C.E.C. C Contactor ARCHITECT. CONTRACTOR SUBMIT CONSTRUCTION DRAWINGS TO ALL GOVERNMENTAL AGENCIES (C.E.C.) GR Ground �� AND UTILITY COMPANIES HAVING JURISDICTION INCLUDING POLICE AND FIRE DEPARTMENT FOR 3. BALLAST AND LAMP SHALL BE ENERGY SAVING TYPE CERTIFIED BY 6 R1-1 AF Air Flow Switch CALIFORNIA ENERGY COMMISSION C.E.C. •2 MS-1, MS-2 MlcroSwitch 1• ��� THEIR REVIEW AND APPROVAL FOR CONSTRUCTION. (C.E.C.) NO Ansul Pyrochem CHIN S SINGLE POLE TOGGLE SWITCH 20 AMP, 120 V ' ST-3 a-3 -R0 C-RD C-RD HEIGHT AS REQUIRED '"" A '� wit NC-PR NO-8K No-BK 3. CONTRACTOR'S BID SHALL NOT BE LIMITED TO THE WORK SHOWN ON THE PLANS AND SPECIFICA- Ss THREE WAY SWITCH 20 AMP, 120 V NC-BR NC-BR TIONS. ALL PREMIUM OVERTIME COSTS, UTILITY CHARGES, COST FOR TEMPORARY UTILITY FOR ADA BETWEEN a _i_NC SPARE RELAY CONTACTS CAN ' S4 FOUR WAY SWITCH 20 AMP, 120 V 36"-48"AFF _4_No z. REQUIRING t I °TO cet4 VOL DOWN ITEIAS PANDA RESTAURANT GROUP INC. SERVICES, ALTERATION, DEMOLITION AND EXTENSION WORKS, PLANCHECK/INSPECTION FEES, 2.00,ji. SH T MHON MISCELLANEOUS CONTINGENCY COSTS, ETC., SHALL BE INCLUDED IN THE BID.(THE CONTINGENCY SO DIMMER SWITCH 1800 WATTS, 15 AMP MINIMUM, 120 V 9 ,-16-`x"-$ DISCHARGES,SUCH AS SHUNT R1-R5 TRIP. SIGNALS,ETC... 1683 Walnut Grove Ave. COST SHALL NOT BE LESS THAN 25% OF OVERALL ELECTRICAL BID. CONTRACTOR SHALL �'Y r> e I a v Contacts____„__, Rosemead, California IDENTIFY THE CONTINGENCY AMOUNT IN BID DOCUMENT) SM MOTOR RATED SWITCH H.P. RATED t0 R4 R2-1 TER NAL FOR FIELD -el SINGLE RECEPTACLE, NEMA RATING AS NOTED 0 wH = G PANEL,o1DRY BUILDING N is 91770 R3 "° FOR SIGNAL ONLY 4. ALL EQUIPMENT SHOWN IS NEW, CONTRACTOR FURNISHED AND INSTALLED, UNLESS OTHERWISE i DUPLEX RECEPTACLE 20 AMP, 120 V GROUNDING TYPE. 04.G. TYPE. - HEIGHT AS ii 'Yw 0 wH _ R2-2 MS-2 Telephone: 626.799.9898 NOTED. IF CONTRACTOR PROPOSED TO SUBSTITUTE FOR EQUIPMENT SPECIFIED, HE SHALL REQUIRED �,�, , ' � NC C Facsimile: 626.372.8288 SUBMIT HIS REQUEST FOR CONSIDERATION TO THE OWNER AND ENGINEER PRIOR TO THE BID IN DOUBLE DUPLEX RECEPTACLE 20 AMP GROUNDING TYPE �G. TYPE. - FOR ADA 12 G, .' --•ac-'"" I - 1' ° •- = R3-1 �'� R4-1 WRITING. ALL SUBSTITIONS MUST BE REVIEWED BY THE ENGINEER. SUCH REVIEW SHALL NOT BETWEEN _ No •- _ Nc c - c c RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE REQUIREMENTS OF THE DRAWINGS AND .i11, CEILING MOUNED DUPLEX RECEPTACLE, SAME AS ABOVE 15 -48 AFF 13 _-.214C +�o� -244CNe SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE AT HIS OWN EXPENSE FOR ANY ��& �"'°` -0c77 11: CEILING MOUNTED DEVICES FOR CASH PODS AND PRODUCT ISLAND. _ ,, NC3-2 �„�, c4"2 CHANGE RESULTING FROM HIS PROPOSED SUBSTITIONS WHICH AFFECT OTHER PARTS OF HIS OWN t4 ;,a,a„ c All ideas, designs, arrangement and plans indicated - ''��'t`= 0 or represented by this drawing are the property of WORK OR SUBSTITUTIONS WHICH AFFECT OTHER PARTS OF HIS OWN WORK OR THE WORK OF REFER TO ARCHITECTURAL FOR EXACT LOCATION - WINE_ Panda Express Inc. and were created for use on OTHER CONTRACTORS. LIGHT INPUT 12OVAC H2-H5=LINE, N2-N5=NEUTRAL - �- this specific project. None of these ideas, designs, Of P.Q.S. DATA OUTLET TO DATA TERMINAL AND - 1S - BKR LS-o1 s --�� --MT '�'O � '' � - _Motor Tips PH volt HP FLA BREAKER arrangements or plans may be used by or disclosed Exh-1 Exh 3 208 1 3.6 15 Amp to any person, firm, or corporation without the 5. THE ELECTRICAL DRAWINGS, CONDUIT RUNS, WIRINGS AND ELECTRICAL INFORMATIONS ARE DIA- TELEPHONE OUTLET WITH 3/4" CONDUIT TO TEL BACKBOARD 16 written permission of Panda Express Inc_ Sup-3 Sup 3 208 1 3.6 -- Amp P P GRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION Exh-2 Exh 3 208 1 3.6 15 Amp OF EQUIPMENT OR OUTLETS. DI P.O.S. DATA OUTLET WITH 3/4" CONDUIT TO DATA TERMINAL - HEIGHT AS 17 REQUIRED 3 PHASE 201V 6. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL ON TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD FOR ADA _ ST-1 °1-n_� LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENTS. 1e ` BETWEEN - ;,�,r;;► ALT?_xl «H_1 GR REVISIONS: [I► FLOOR TYPE DUPLEX RECEPTACLE 20A GROUNDING TYPE 15"-48"AFF 3 - >� T T3-- - NQIES 19 3 PHASE 208Y -` DENOTES FIELD G Q ST-3 of-3 DENOTES INTERNAL VAR DIG 7. ALL RECEPTACLES AND OUTLETS MOUNTING HEIGHTS AND EXACT LOCATION SHALL BE COOR- V CLOSED CIRCUIT TELEVISION ANTENNA OUTLET L1 E.r ,T1_ ARE caOR DINATED WITH ARCHITECTURAL DRAWINGS ELEVATIONS PRIOR TO ROUGH-IN WORK. 20 I-TZ-,�C�T --� SUP-3 BK-BACK mar-YELLOW L3 T3 T3 �¢ /O/ MOTOR OR CEILING EXHAUST FAN ~` - - PR-PUAe BROWN PURPLE 3 PHASE 208Y OR-ORANGE OR/BL- ORANGE/BWE 8. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY TYPES OF CEILING SYSTEM AND J JUNCTION BOX TO SUIT THE FIELD CONDITIONS 21 sT-2 a-2 =wI�eTE ? BLUE/RED TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED .+PUr _ : ,"2 ''M EXH-2 GR (SD'E) &/GN CEILINGS. FIXTURES SHALL BE COMPLETED WITH NECESSARY MOUNTING HARDWARE AND B. NOTES: 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS INDICATES DEVICE 223,x_ ,;TM; U 4,3_00,13__21 RDS ) RED/ N ACCESSORIES. FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE LABELED FOR USE CONTROLLED DRAWING SHOWN DE-ENERGIZED IN SUCH LOCATIONS. 2. DEVICES AND COVER PLATE COLOR AS SELECTED BY ARCHITECT, SEE 23 NOTE IF WALL MOUNT PREWIRE,OR FIELD INSTALLED FIRE SYSTEM MICROSWITCH. THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLET, UNLESS TERMINALS SHOWING FACTORY WIRING 9. ALL RECESSED LIGHTING FIXTURES, PANELBOARDS, SWITCHES, ETC., MOUNTED IN FIRE RATED NOTED. 24 MUST BE FIELD WIRED. 18 x 18 x 6 Box Si STRUCTURES SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE 3. RECEPTACLES IN BATHROOM, LAUNDRY ROOM, AND KITCHEN Size RATING AS THE STRUCTURE. SINK AND EXTERIOR LOCATIONS SHALL BE GROUND FAULT TYPE (GFI) 4. COVERPLATES IN KITCHEN AND UTILITY AREAS SHALL BE STAINLESS XAUST _ /��, �` ISSUE DATE: 10. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR STEEL. K I 'C N S I A RA I A 1ST PERMIT APPLICATION: 1/09/09 SHALL STRATEGICALLY LOCATE ACCESS BOXES, ETC., WHICH SHALL BE READILY ACCESSIBLE. EMERGENCY CIRCUIT. LOCK ON DEVICE FOR BREAKER SERVING ___ ALL LIGHTING FIXTURE WIRING, BALLASTS, J-BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE N. T. S. 2ND OPENING. ._/'1_._ BREAKER 3RD 11. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING EQUIPMENT -- 4TH -fi"1- SWITCH AND FUSES 5TH SHALL BE IN ACCORDANCE WITH DIVISION 15 AND ASSOCIATED DRAWIGS. CONTRACTOR OBTAIN al SWITCH THE REQUIRED MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE ALL EQUIPMENTS, 6TH RACEWAYS, WIRINGS, ETC., AS INDICATED THEREON AS PROVIDED UNDER THE ELECTRICAL WORK. DISCONNECT SWITCH WITH FUSE -- N �.�-� SHORT CIRCUIT COMPLIANCE NOTES 12. ALL FINAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT SHALL BE MADE BY THE CONTRACTOR Q11 '� } M ) 1. VERIFY AVAILABLE FAULT WITH SHELL CONTRACTOR UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL CHARACTERISTICS AND U.L. LISTING PRIOR TO PUSHBUTTON OPERATOR FOR ELECTRIC DOOR �- AND SERVING UTILITY COMPANY AND ENSURE CONNECTION. r'\ 2 SETS OF (4)-3/0 & THAT THE MAXIMUM AVAILABLE FAULT WILL NOT Q WATT/HOUR METER SOCKET (1)-#3 GND IN 2-1/2"C. EXCEED SHORT CIRCUIT RATING OF EQUIPMENT. DRAWN BY: SGW 13. THE CONTRACTOR SHALL VERIFY THE LOAD INPUT VOLTAGE OF ALL EQUIPMENT PRIOR TO INSTALLATION. ACCEPTING ANY EQUIPMENT RESULT IN LOAD INCREASE SHALL BE THE © TRANSFORMER 400A-3P)RESPONSIBILITY OF CONTRACTOR. M M l 2. ALL CURRENT CARRING DEVICES SHALL BE U.L. W' CURRENT TRANSFORMER \____,/ LISTED AND BRACED TO WITHSTAND THE MAXIMUM 14. ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE RATED WALLS AND PARTITIONS MUST BE AVAILABLE FAULT AT ITS TERMINUS SEPARATED BY DISTANCE OF 24 IN. HORIZONTALLY, IN ACCORDANCE WITH I.B.C. SEC. 711.3.2. ® SWITCHBOARD I PANDA PROJECT#: 54-09-D2116 OPENINGS IN FIRE RATED WALLS GREATER THAN 16 SQ. IN. MUST BE FIRE STOPPED. i 3. SERIES/COMBINATION SHORT CIRCUIT RATING PROJECT#: 0821 / RDG0809 .. PANELBOARD M i MAY BE USED WHEN OVERCURRENT DEVICE 15. PROVIDE AN ADDITIONAL JUNCTION BOX (SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS ' \� COMBINATIONS ARE LISTED UNDER U.L. 67 EXCEEDS THE MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET. ® TELEPHONE CABINET WITH BACK BOARD ALL C.B. IN STANDARD AND INSTALLATION SHALL COMPLY IZl 0-2 HR. MANUAL BY-PASS TIMER FOR LTG.,ZONE CONTROL. PROVIDE AS REQUIRED 1 PNL"A" PNL"B" PANELBOARD WITH NATIONAL ELECTRICAL CODE (N.E.C.) ARCHITECT : 16. CONDUCTORS SHALL BE COPPER THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED. BY C.E.C. FOR ELECTRIC METERED SPACE OF GREATER THAN 5000 S.F. SHALL BE ARTICLE 110-9, 110-22 AND OTHER USE PROPER TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE ROUTE FEEDER TO SHELL ELECTRICAL TYPE BAB APPLICABLE SECTIONS. RPG WHERE CONDUCTORS ARE BEING USED. HIGHER AMPACITY CONDUCTOR AND LARGER RACEWAY C. NOTES: 1. BREAKERS, SWITCHES, FUSES, METER SOCKETS, AND CURRENT CARRYING DISTRIBUTION EQUIPMENT. VERIFY 400A 400A SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS AS INDICATED IN NEC DEVICES SHALL BE DESIGNED TO WITHSTAND MAXIMUM AVAILABLE FAULT REQUIREMENTS AND COORDINATE WITH 125A 128 4. APPLICABLE SERIES/COMBINATION RATED TABLE 310 AND ELSEWHERE IN CODE. CURRENT (AFC) ESTABLISHED BY SERVING UTILITY SHELL CONTRACTOR PRIOR TO BID. EQUIPMENT ENCLOSURES SHALL BE CLEARLY 17. ALL FLUORESCENT BALLASTS AND LAMPS SHALL BE CALIFORNIA ENERGY COMMISSION(CEC) 2. SWITCHBOARDS AND PANELBOARDS BUSSING SHALL BE BRACED TO WITH- \- MARKED "CAUTION - SERIES COMBINATION REITER DESIGN GROUP CERTIFIED ENERGY SAVING TYPE. A-1-3-5 STAND MAXIMUM AVAILABLE FAULT 2 SETS OF (4)-3/0 & SYSTEM RATED __ AMPERES. IDENTIFIED ARCHITECTS, INC. CONDUIT HOME RUN TO SOURCE INDICATING PANEL "A" CIRCUITS #1, 3 & 5 (1)-#3 GND IN 2-1/2"C. REPLACEMENT COMPONENTS REQUIRED." IN 7965 SW CIRRUS DRIVE 18. DO ALL DRILLING, CUTTING, CHANNELING AS REQUIRE TO ELECTRICAL WORK AND INDICATED OR COMPLIANCE WITH 2002 NEC SECTION BEAVERTON OREGON 97008 HEREIN SPECIFIED. ALL HOLES, CURBS, ETC., IN FLOORS, CEILINGS AND WALLS SHALL BE CONDUIT RUN CONCEALED IN CEILING SPACE OR IN WALL TOTAL DEMAND LOAD = 125A+ 128A= 253A< 400A 110-22. END-USE EQUIPMENT SHALL ALSO (503)574-3036 FAX(503) 574-2916_ PATCHED, UNLESS INDICATED OTHERWISE. PAINT ALL EXPOSED ELECTRICAL RACEWAYS, CABINETS, BE MARKED WITH THE HIGHER SERIES ENCLOSURES AND FITTING TO MATCH IN COLOR ADJACENT SURFACES IN FINISHED AREAS. - - - CONDUIT RUN BELOW FLOORS OR IN GRADE I I I ASAM COMBINATION INTERRUPTING RATING AS PER 19. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC., TO MAINTAIN > >\ HASH MARKS INDICATE QUANTITY OF CONDUCTORS. NO HASH MARK INDICATES 2002 NEC SECTION 240-83(c). N THE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENTS #10 2 #12 AWG. U.O.N. (#10 INDICATES #10 AWG. CONDUCTORS) SIZE OF CONDUIT SHALL .T.S. STAMP: PENETRATING INTO FIRE RATED ENVELOPS, SPACES ETC. BE BASED ON TABLE 1, CHAPTER 9 OF N.E.C. AMD TABLE 3A AND 3B SHALL ��F,© PROFe DETERMINE THE CONDUIT SIZES. MINIMUM CONDUIT SIZE SHALL BE 3/4". c.,'`\ �LyGINEFR Sio 20. EMERGENCY LIGHTING SHALL BE PROVIDED PER U.B.C. AND SHALL BE DESIGN TO PROVIDE i719 y� MINIMUM REQUIRE FOOTCANDLES AND LUMENS. PROVIDE ADDITIONAL EMERGENCY ILLUMINATION -'T TELEPHONE CABLES IN CONDUIT r AS REQUIRED BY INSPECTION AUTHORITIES HAVING JURISDICTIONS. -TV TELEVISION ANTENNA CABLES IN CONDUIT -D DATA/COMMUNICATION CABLES IN CONDUIT OREGON 21. ALL ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE D. NOTES: 1. ALL CONDUIT SHALL BE RIGID STEEL OR EMT. FLEXIBLE CONDUIT SHALL v0 'AFC, fi, NO�`'D ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA. [NON HEALTH CARE FACILITY INCLUDE BE LIMITED TO 72" FOR FINAL CONNECTION TO LIGHTING FIXTURES OR TIME SWITCH y�F RO��`' OSHPD NOTES FOR HEALTH CARE FACILITY] (- I RANK MOTORS, INCLUDING GROUNDING CONDUCTOR. P.V.C. CONDUIT MAY BE MECHANICAL WITH EXPIRES 12/31/10 FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT USED ONLY FOR UNDERGROUND, RE-SIZE CONDUIT AS REQUIRED ASTRONOMICAL DIAL.C5- 50% OF OPERATING WEIGHT MOUNT ABOVE PANEL. FIXED EQUIPMENT ON STRUCTURE o 0 0 TO INCLUDE GROUNDING CONDUCTOR. EMERGENCY POWER AND COMMUNICATION EQUIPMENT ON GRADE 50% OF OPERATING WEIGHT EMERGENCY POWER AND COMMUNICATION ON STRUCTURE 75% OF OPERATING WEIGHT 2. TELEPHONE AND TELEVISION CABLES MAY BE PREWIRED BY LOCAL LIGHTING CONTACTOR TEL/COMM/CABLE T.V. COMPANY. FOR FLEXIBLE MOUNTED/3 X HORIZONTAL FORCE.? X THE ABOVE VALUES. SIMULTANEOUS VERTICAL FORCE SE -I I- 20 AMP MECHANICALLY HELD (TWO WIRES CONTROL) RELAY CONTROLLING CKT. PANDA EXPRESS NEUT • INDICATED WITH PROGRAMMABLE TIME SWITCH CONTROLLING COIL. ASSIGN CONTROL /TO EXTERIOR SIGNS CONDUIT, BUSDUCT, CABLE TRAY, WIREWAYS, ETC., SHALL BE BRACED IN A ACCORDANCE TIGARD TOWN SQUARE WITH "GUILDELINE", PUBLISHED BY SMACNA AND PPIC. CHANNEL AND DURATION. 22. BRANCH CONTROL CIRCUITING AND WIRE COUNT MAY NOT BE INDICATED ON THESE PLANS. NL NIGHT LIGHT CONTROLLED BY CHANNEL 1 © + ..L .l CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE MIT A - I T EL EVENING LIGHT CONTROLLED BY CHANNEL 2 37 39 41 16230 PACIFIC HWY. SUITE 100 WITH PLAN NOTES AND AS PERMITTED BY AUTHORITY. CONTRACTOR HA SHALL SUBMIT S BU L DRAWINGS AS A PART OF RECORD DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING TO PANEL °A" FOR SIGNS TIGARD, OREGON JURISDICTION (ANJ). DL DAY LIGHT (INTERIOR LIGHT) CONTROLLED BY CHANNEL 3. PROVIDE 120 VOLT + 0 • , 23. ELECTRICAL INSTALLATION SHALL COMPLY WITH NATIONAL ELECTRICAL CODE (2002 NEC) ADAPTED CONSTANT CIRCUIT TO EMERGENCY INVERTER, IF ANY. CIRCUIT VERIFY QUANTITIES OF POLES BY THE JURISDICTION AND ANY LOCAL SUPPLIMENT. REQUIRED WITH CIRCUIT QUANTITIES AC AIR CONDITION (24V CIRCUIT) CONTROLLED BY CHANNEL 4 BYPASS SWITCH E EXISTING LOCATE ADJACENT NOTICE TO CONTACTOR. UON UNLESS OTHERWISE NOTED THESE DRAWINGS ARE SUBJECT TO AN APPROVAL OF THE SI 6N CONTROL. SYSTEM E4 • O BUILDING DEPARTMENT, FIRE MARSHAL, UTILITY COMPANY AND GFI GROUND FAULT INTERRUPTER N.T.S. SYSTEM OTHER AGENCIES AUTHORITY HAVING JURISDICTION (AHJ). DC DEDICATED CIRCUIT ELECTRICAL DETAILS BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE DESIGN AND SCHEDULES CONTRACTOR HAVE REVIEWED THE PLANS THOROUGHLY AND +12" INDICATES MOUNTING HEIGHT AM% CONSULTANTS Nc. ACCEPT FULL RESPONSIBILITY OF PLAN CORRECTIONS AND FROM FINISHED FLOOR TO CENTER OF DEVICE 1515 SE WATER AVE, SUITE 400 ASSOCIATED CONSTRUCTION COSTS REQUIRED BY AHJ. MO PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: STEVE WATKINS s • • • • • • • ••• • • • • • • ••• • • • • • •• • • - - Cz. B A B A %// 4.7:- : (5) E _ _ w • to ® •. 0 0 0 �F � ' MECHANICAL KEY NOTES: '' cN � N�s — - -; - I INSTALL GREASE EXHAUST HOODS FURNISHED BY PANDA. HOOD 1 ' ' - - - - -- - I ' 1 SHALL BE ONE CAPTIVEAIRE 4824-ND HOOD EXHAUSTING 3,000 1 ( CFM. SUPPORT FROM STRUCTURE ABOVE WITH UNISTRUT AND ALL PANDA RESTAURANT GROUP INC. I -----n �. --- I - - THREAD ROD. MOUNT HOOD PER LOCAL CODE REQUIREMENTS. 1683 Walnut Grove Ave. REFER TO PLAN FOR HOOD CONNECTIONS. SEE CODE COMPLIANCE Il / ' i DRAWINGS ON SHEET M-3.0 AND CAPTIVEAIRE HOOD DRAWINGS Rosemead, California i I / ' ' � � % I FOR ADDITIONAL REQUIREMENTS. 9 �7 ( / I \ I Telephone: 626.799.9898 ' _ - I-) ' _ __�_ - - _ ____ _ _ _ _ GREASE EXHAUST DUCT, FROM INLET OF ROOF MOUNTED GREASE Facsimile: 626.372.8288 2 \\ - - — ' . �`'-�o `.. 250 p 2 EXHAUST FAN, CONNECT TO EXHAUST HOOD COLLAR. FABRICATE DUCT / En� 12x1 • FROM 16 GA. STEEL WITH WELDED SEAM CONSTRUCTION. SEE HOOD \ �' 15• DRAWINGS ON SHEET M-3.0 AND CAPTIVEAIRE DRAWINGS TO VERIFY COLLAR 1 + / \ j 500 CE-1 _ I I 12x12 4 j Odd 8x8-4 SIZE. ENCLOSE DUCT IN 1 HOUR FIRE RATED SHAFT OR WRAP DUCT WITH - - \ CS_1 1 CS-2 3M 15A, UL 1978 FIRE BARRIER DUCT WRAP OR EQUAL. All ideas, designs, arrangement and plans indicated I 1 - ` \ ! -'-�'-` —' fC �- Panda Express Inc. and were created for use on II i or represented by this drawing ore the property of / ' \ \ I \ Lid l_�Ii I J I M PROVIDE A NEW PROGRAMMABLE THERMOSTAT W/ REMOTE SENSOR this specific project. None of these ideas, designs, / `� \ -!— \ 111 I 8� orrongements or pions may be used by or disclosed I / N \ CEIL 0, Ir FOR EACH A/C UNIT AT THIS LOCATION. STACK THERMOSTATS AT 48" to any person, firm, or corporation without the I N I . 200 l A.F.F. FOR UPPER UNIT AT THIS LOCATION. LOCATE SENSORS written permission of Panda Express Inc_ + I // { I i SEON OF 24x2 :�.,3`�� 250 , NEAR RETURN GRILLES VERIFIED WITH PANDA'S PROJECT MANAGER. SEE / I ; ® ��) o CR-1 ,p �I, 12x12, TEMPERATURE CONTROL DIAGRAM ON SHEET M-2.0 FOR ADDITIONAL \ i ACE-1 1R 10 5 INFORMATION. THERMOSTATS TO HAVE 5 DEGREE DEADBAND. — / + ` \ / I \ ! ©� kr, � ,....! � �� � REVISIONS: / \ I I r INSTALL GREASE EXHAUST FAN WITH CURB (EF-1 AND EF-2), AND 1 / I \ ISk 100 11 4' MAKEUP AIR (MA-1) FURNISHED BY PANDA. COORDINATE UNIT LOCATIONS nl \ I I \ + 1200 WITH STRUCTURE AND THE OWNER'S FIELD REPRESENTATIVE. ' \ / 20 I $ I n 24x24 ADJUST DUCTWORK ACCORDINGLY. FIELD VERIFY WITH LANDLORD Gil REFRIG. COMPRESSORS / 1 1 -- __�=1 1 I \ ■ CR-1 FOR ALL ROOF PENETRATIONS I \ I / � PR /��a� '� ;�i 12x12 '1 \ , \, 20'' 7 ';: '� 12x1 INED 5 UNIT AND DUCTS, ROUTE DUCTS DUC THROUGH ROOF CURB AND TRUSSES. —�JI Anil" / I INSTALL DUCT MOUNTED SMOKE DETECTOR AT MAIN RETURN AIR e•8 Imo, ` ' I —1� $,, . ,,,. . I DUCT PER IMC 2003, SEC. 606, PROVIDED BY ELECTRICAL N\ w� I ii� CONTRACTOR. DETECTORS SHALL BE INTERLOCKED TO SHUT DOWN L._... AC \ 14 / ■■w.. ' 00 15Q // ROOFTOP UNITS UPON DETECTION OF SMOKE. PROVIDE ALL CONTROL 9 \ , _ _ / ' I -4 ( � WIRING NECESSARY TO PERFORM THIS OPERATION. \ I / r �� I 1 / ' ISSUE DATE' - r/� \ / I 7 4 'j % ! 2S)i __i - J / I 7 12"x 18"SA & 26"x 12"RA UP THROUGH ROOF AND CONNECT TO UNIT. 1sT PERMIT APPLICATION: 1/09/09 10 -0" RADIUS FROM INTAKES / K-• • • .�♦ .�i, 105 / 2N0 / I �� a '� --- —' :I NEW ROOFTOP HVAC UNIT PROVIDED AND INSTALLED BY LANDLORD. 3RD ♦♦ ►♦♦v� .♦.♦i�♦♦♦♦♦,,,♦���♦♦♦♦♦♦�♦♦♦♦♦,1� CONNECT DUCTWORK TO UNIT AND 0 PROVIDE THERMOSTAT AND 4 ���� �v�v:♦v;6.4�♦���;��♦v:��•�'��` ♦♦:♦_♦♦_,'_�♦�♦��♦v �� 6! I TEMPERATURE CONTROL WIRING FROM THE UNIT TO THE THERMOSTAT 1 1 \ N /�' ►�♦ Z:Cwi=1 - ♦gymmom I 1 J16-4 1-. AND OTHER CONTROL DEVICES. 5TH 6TH / \ - _ ` - ` - ! ■ 00 A 9 FOR GAS OR WATER CONNECTION, SEE PLUMBING DWG. / \ , 1111 I pr ii. � • \ 1 i -� 16"x 1 2 MA DUCT CONNECT TO 24x12 RISER FROM SUPPLY PLENUM. I ■� 1 1,200 CFM EACH. DRAWN BY: BLM -- �I►1 • >^ I r. 1. 12 ►►■■t■■■ _ - I - - - — - 1 - - - - - - - - - - - - - /J 1 \ani °�■■ice`■ 40a / / W - 1 1 PROVIDE DUCT LINER AT MAIN TRUNK. 20x24 UP.III® 1 1 x12 �2� ■ sh I Q 4 1 \ 16x16 _ 2 © +0 1x,12 • - - - - _ + �I �� :� r� f��^ CS 1 j III _ 12 3 INCH PVC FLUE VENT AND COMBUSTION AIR +�••••���• I _, '-� –' — -- �'- INTAKE FOR WATER HEATER UP THROUGH ROOF PANDA PROJECT#: S4-09-D2116 ,+ -r- _ -� I � ::;� J , ro. : :O::T:: :::FI . PROJECT#: 0821 / RDG0809 MA ,- ' . / I )( I \ / 1\ / I I / k. _ . \ / Mr __u�'____' *;:.2:0� // ` _ 1 MIN. 3 -0 ABOVE ANY AIR INTAKE i / +� , Is : I WITHIN 10 -0 OF DIRECT DISTANCE. RPG / \ / \ / _ I �" \ ♦ 400 L/ ! ,' .e v I \ + / \ 1 ,16x1 ►♦4 t4 1 I it ' ARCHITECT 4 9 I ' �,�,� { /��I��♦�� 14x14- + NEW RESTROOM FAN PROVIDED BY PANDA AND INSTALLED BY AI — -- 1\, / ', I�, ._ ` �� �`I�j±♦� CS- �; \` W� - L0 ' . 14' CONTRACTOR_ COORDINATE EXACT LOCATION OF UNIT WITH " I , ' \ A ►�I�♦♦:♦� o ' '� 16 6 4 OWNER'S REPRESENTATIVE. SHIM ROOF CURB LEVEL. .a►.... CS 1 10'-0" FRO OSA 4fNTAKE } ' // 16x16~�t- }1 400 I « - / I I 'COQ ,, _ 20x24 LINED DUCT UP THROUGH ROOF TO MA-1. PROVIDE TRANSITION LTi // ►,� ;��// 14x14-4 + III -- 1 RErIER DESIGN GROUP D 4 ,� ... ' i CS-2 I 0 ,,� AND FLEXIBLE CONNECTION TO FAN DISCHARGE. VERIFY SIZE WITH ARCHITECTS INC.II ,.. \ i 1 / 16x1 I I I 2 .1 — /Ate/ I © © CAPTIVE HIRE DRAWINGS. 7965 SW CIRRUS DRIVE \ _`�` I — / / I I T i `' I 12� I BEAVERTON,OREGON 97008 I I 5'-0" FROM / CEILI G M• ENSO I _ ,,�►, �� =��= p (503) 574-3036 FAX(503) 574-2916_ EQUIPMENT / / AC n 0) n ' . 1:-,��- „ -ir...; _„,tei�►��_ _ .4,. _�►.lip _ _ _ „ , _ _ _►� �� �. ,00 -. I 1 __a■ ♦♦♦♦♦,. .♦-♦-♦-♦-♦.♦.♦-♦-♦-.A.. .♦...♦.♦4►-♦-♦-♦-♦i-♦-♦-♦-A-♦-♦..♦-�.♦�♦-♦-♦�1►♦-♦-♦.1,fr I 1 , /� I IF:IL, --�' ■'=!=*=�� ��= I � 20� , �0 STAMPPRo,4 t, ‘1• ° ® la IIII _.., '�CNINE si 1 8x8 cV 1400 : , 5, 9- -- 8 9 I } Cs-1 tool. ��`i �� i P I + I 6 24x2 t O / _ — OREGON cq�Y C. B AR�tiS 600 f 600 16x16 4 \ ° )( a )( * )\ * /( I• 16x16-4 .t EXPIRES 12/31/09 4 I ' CS-1 CS-1 I g I I I 1I ` I I ® PANDAEXPRESS 7iiiii 0 JIM= 1 -- - - - - _ - - - ,4 , _ - : _..: .. TIGARD TOWN SQUARE 1 I I 0 II le 0 0 \ . . , , ,,, \ I i i ' ! \_ 1 ' ! __ 16230 PACIFIC HWY. SUITE 100 I i TIGARD, OREGON 1 I I ' . M I •SYSTEM ROOF 1 PLAN 2 DESIGN HVAC PLANS M 1 .0 1/4” = 1'-0” M 1 .0 1/4" = V-0" CONSULTANTS tic. 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: BRUCE MYERS • • • . . ••••• •• •• • • • • MECHANICAL SPECIFICATIDNS: ' : : ' ' ••EXHAUST FAN SCHEDULE PAC <AGED A / C UNIT SCHEDULE A/C UNIT 1. THE WORK INCLUDES installation of HVAC systems, including grease �,r•�" ""`�.,� exhaust fans and make-up air unit for kitchen hoods, kitchen FAN NO. ® UNIT SYMBOL La m (-_ .- hoods, space heating/air conditioning systems, supply, return, exhaust, W © W © P� E)c:4, :: and grease exhaust ductwork, grilles, registers, diffusers GASKET (SUPPLIED g g 9` com plete control system, interlock wiring on the operation of LOCATION ROOF ROOF ROOF W/CURB) the kitchen hood, exhaust fans, and make-u air unit, duct, insulation, and LOCATION ROOF ROOF - 2 WIDE-18GA. G_I. P � �f r ANCHORS. SECURE related items necessary for a complete functioning system as AREA SERVED KITCHEN GREASE KITCHEN GREASE RESTROOMS / '- - .1). 1- (r) NAILER STRIP "" . 1---' TO UNIT W/(2) #14 SMS indicated on the plans. Furnish all new materials and equipment. EXHAUST HOOD #1 EXHAUST HOOD #2 4J CFM 2,500 2,400 . (I) �j��! � MIN. (4) PER UNIT � •A A 1 ( ) 2. DRAWINGS for HVAC work are diagrammatic, showing the general FAN DUTY AIR EXHAUST AIR EXHAUST AIR EXHAUST -' 1 • ° • 26 GA. G.I. COUNTER location, type, layout and equipment required. ThegDrawings shall U �" TSP (IN W.G.) 0.6' 0.6' ® r► / BELT- Et DRIVEN not be scaled for exact measurements. Refer to architectural and FAN TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL O 0 // manufacturer's standard installation drawings for equipment BELT DRIVEN BELT-DRIVEN DIRECT-DRIVEN TOTAL (BTU/HR) 62,000 62,000 0 ROOFING FELT BY OTHERS connections and installation requirements, as required. Furnish .Q and install ductwork, connections, accessories, offsets, and FAN ARRANGEMENT UPBLAST UPBLAST DOWNBLAST �l L3 SENSIBLE (BTU/HR) 51,800 51,800 �, DUCT ft / CANT STRIP BY OTHERS materials necessary to facilitate the system's functioning as J �g 7. _ a /� indicated by the design and the equipment indicated. PANDA/CAPTIVEAIRE PANDA/CAPTIVEAIRE PANDA/CAPTIVEAIRE °o CHI N PROVIDED BY: �i ROOFING BY OTHERS � AMBIENT ( F) 105 105 4.44....\.N...,... 3. CODE COMPUANCE: All work covered by this section shall conform to the Oregon Mechanical S ecialt Code 2007 and other Authorities C.F.M. 3,000 3,000 600 Specialty COIL ENTERING 67 WB/80 DB 67 WB/80 DB PANDA RESTAURANT GROUP INC. ` having jurisdiction. In case of conflict between requirement, the most � PRE-FAB CURB '4 ' T restrictive one shall apply. �,,,, T.S.P. 1.50' 1.50' 0.25' ���. HEATING (BTU/HR) 82,000 , 115,000 (INPUT) 2 STAGE 82,000 , 115,000 (INPUT) 2 STAGE 1683 Walnut Grove Ave. Rosemead, California 4. COORDINATE with the work of other Sections, equipment furnished by 1 B.H.P. 1.28 1.28 0.14 91770 others, and requirements of the Owner. Provide duct rises and o POWER SUPPLY 208V/30/60HZ 208V/30/60HZ ROOF STRUCTURE drops as required for field installation and trade coordination. °; Telephone: 626.799.9898 SEE STRUCTL DWG'S Notify Architect of any discrepancies before starting work. Work a- FAN R.P.M. 1001 1001 1400 COMPRESSOR (RLA) 17.3 17.3 Facsimile: 626.372.8288 shall be performed by experienced tradesmen and their work shall be Q of high standard acceptable to the Architect. MOTOR H.P. 1.50 1,50 1/6 f-'5.- CONDENSER MOTOR (FLA) 1.5 1.5 5. DUCTWORK: Duct systems shall be rigid and shall be constructed, installed, ROOF CURB DETAIL sealed and insulated as provided in the International Mechanical Code_ ELEC. CHARACTERISTICS 208V/3PH/60HZ 208V/3PH/60HZ 120V/1PH/60HZ ``' EVAPORATOR MOTOR (FLA) 7.5 7.5 Sheet metal shall be in accordance with ASHRAE and SMACNA standards. Sheet or ideas, designs, arrangement and he property indicated 0 or represented by this drawing are the property of N.T.S. metal shall be galvanized sheet metal of lock-forming quality, ASTM A-525. o Panda Express Inc_ and were created for use on MOTOR R.P.M. 1725 1725 - MIN. CIRCUIT AMPACITY 30.6 MCA, MOCP = 35 30.6 MCA, MOCP = 35 this specific project None of these ideas, designs, Unless otherwise noted, duct dimensions on drawings are net inside arrangements or plans may be used by or disclosed clear dimensions on lined ducts, or sheet metal dimensions on to any person, firm, or corporation without the unlined ducts. All angle iron used for support shall be galvanized. MOTOR SPECIAL FEATURES OPEN DRIP-PROOF OPEN DRIP-PROOF OPEN DRIP-PROOF REMARK BY CARRIER 48HJR-006 BY CARRIER 48HJR-006 written permission of Panda Express Inc_ Round rigid ductwork shall conform to SMACNA standards. VERTICAL DISCHARGE VERTICAL DISCHARGE 1. VENTED ROOF CURB 1. VENTED ROOF CURB 1, ROOF CURB COMPLETE WITH ROOF MOUNTING COMPLETE WITH ROOF MOUNTING 6. SEAL all duct seams, transverse and longitudinal, air-tight. ACCESSORIES 2. HINGED AND CHAINED 2. HINGED AND CHAINED 2. BACKDRAFT DAMPER CURB, ECONOMIZER, CURB, ECONOMIZER, FAN INSTALLATION FAN INSTALLATION ELECTRONIC PROGRAMMABLE ELECTRONIC PROGRAMMABLE Provide turning vanes at all elbows or offsets exceeding 30 THERMOSTAT WITH REMOTE SENSOR. THERMOSTAT WITH REMOTE SENSOR. (- degrees. FOR DUCT ACCESS FOR DUCT ACCESS HIGH STATIC MOTOR HIGH STATIC MOTOR REVISIONS: r - - - 1 7. GREASE EXHAUST SYSTEM: Provide all grease exhaust ducts fabricated CAPTIVEAIRE CAPTIVEAIRE CAPTIVEAIRE STAINLESS STEEL HEAT EXCH, STAINLESS STEEL HEAT EXCH. NOTE: of welded joint construction of 16 gauge galvanized steel or 18 gauge MANUFACTURER MODEL: NCA16FA MODEL: NCA16FA MODEL: DR12HFA OPER. WT. : 875 LBS APPROX. OPER. WT. : 875 LBS APPROX. PROVIDE ROOF stainless steel. Provide access doors at elbows and offsets per code WT. 190 LBS WT. 190 LBS WT. 35 LBS SEER=13.0 EER=11.0, AFUE=82X SEER-13.0 EER=11.0, AFUE-82X LEVELING CURB - .1 requirements. All elbows shall be long radiused. Duct shall be wrapped AS REQUIRED. r • r •U_ ,. - in UL listed firewrap insulation per manufacturer's installation instructions. _ _ _ _ • 8. DUCT INSULATION: Provide 1" duct liner on all interior rectangular supply & and return air ducts. Provide 2 duct liner on all exterior supply COUNTERFLASHING '. air ducts. Provide 1-1/2" duct wrap on all concealed supply M AKE - U P AIR UNIT S C H E D U L_ E AIR B A L A N C E S C H ducts. Duct liner shall be 3 pounds per cubic foot density neoprene coated E D U L E (1) 2x6 CURB -_ 'i duct liner complying with NFPA 90A, having a "K" value not to exceed LOCATION FLASHING : 0.23. Flame spread and smoked developed ratings shall not exceed BLOWER ITEM SUPPLY AIR RETURN AIR MAKE-UP AIR EXHAUST � � �, 25/50. Apply to sheet metal ductwork with 100% coverage adhesive. SYMBOL & TYPE COOLING MFR. & MODEL CANT STRIP ' Provide additional mechanical fasteners on ducts over 12 wide or SERVICE AREA CFM ESP MOTOR MA-1 0 0 +4 800 0 i 16" high. Mechanical fasteners shall be "Gripnail" or welded pin ISSUE DATE: PACKAGED ROOFING / E-7 7/ and speed clips spaced per SMACNA standards. EF-1, EF-2 0 0 0 -3,000 x 2 1sT PERMIT APPLICATION: 1/09/ 09 /--- l // a r� ROOF-TOP DIRECT FIRED UNIT NONE 5 HP @ CAPTIVE AIRE MODEL: AD-2 AC-1 +2,400 -1,400 0 0 2ND FOR WITH MODULATING 4,800 0.5' 208V/3PH/60HZ APPROX, WT, 870 LBS AN____ ji 9. ACCESS DOOR: Provide hinged access panels in ductwork where shown Q KITCHEN HOOD BURNER AND 3RD ROOF DECK DUCT SIZE TO FIT FAN. and as required for access to dampers or equipment. Provide insulated AIR MAKE-UP INTERMITT. IGN, AC-2 +2,500 -1,400 0 0 TRANSITIONS BY MECH. access doors in insulated ductwork. 4TH BACKDRAFT DAMPER P CONTRACTOR. VERT. DISCHARGE EF-3 - - - -600 5TH 1 0_ AUTOMATIC TEMPERATURE CONTROL: Provide all 350 MBH INPUT. interlock and control wiring for the kitchen hood system, which x TOTAL +4,900 -2,800 +4,800 -6,600 6TH includes EF-1, EF-2, MA-1, and the Ansul system shut down x FOR MAKE-UP AIR UNIT POSITION CONTROL, SEE CAPTIVE AIRE CONTROL DIAGRAM ON M-3.2. THIS DETAIL DENOTES GENERAL FLASHING AND CURB interlock to the make-up air fan. Provide the interlock wiring TENANT SPACE PRESSURE _ +300 CFM CONFIGURATION. VERIFY THE EXACT REQUIREMENTS OF from the kitchen hood ansul system. Upon activation of the ansul THE EQUIPMENT CURBS AND THE ARCHITECTURAL system the make-up air fan shall be deactivated. Provide all ROOFING SYSTEM USED. INSTALL CURBS IN ACCORDANCE necessary controls and wiring for a complete and operable system. WITH THE ROOFING MANUFACTURERS INSTRUCTIONS. Interlock the grease exhaust fans and the make-up air unit to start DRAWN BY: BLM COORDINATE WITH ARCHITECTURAL DETAILS AND simultaneously from the switch at the hood provided. & G SPECIFICATIONS. Provide a seven day programmable thermostat with night setback for DIFFUSER & RILLE S C - E D U L E each air conditioning system. Thermostats to have remote sensors. Provide thermostat and control package to control MA-1 heating. Heating to maintain minimum of 50 degrees (adjustable) EXHAUST FAN (RESTROOM) D ETAIL discharge air temperature. - PANDA PROJECT#: S4-09-D2116 DESIGNATION MANUFACTURER MODEL NO TYPE NECK SIZE MOUNTING STYLE NC MAX REMARKS PROJECT#: 0821 / RDG0809 N.T.S. 11. TEST AND ADJUST each piece of equipment and each system as . required to assure proper operation. CS-1 ANEMOSTAT X 1 C4 ADJUSTABLE CURVED BLADE _ 24x24 LAY-IN TEE BAR < 30 SQ. TO RD. ADAPTER. 24x24 FACE Eliminate noise and vibration, and assure proper function of CS-2 ANEMOSTAT X 1 C40 ADJUSTABLE CURVED BLADE FLAT SURFACE MOUNT < 30 SQ. TO RD. ADAPTER, OBD. controls, maintenance of temperature, and operation. Obtain inspections - required by local code. Guarantee the work and the installation for ARCHITECT : one year after acceptance by the owner. Furnish the Owner with CR-1 ANEMOSTAT GC5 1/2" x 1/2"x 1/2" EGGCRATE 24x24 TEE BAR < 35 24x24 FACE two complete sets of as-built drawings indicating all installed CE-1 ANEMOSTAT S3HOD FIXED LOUVERED FACE w FLAT SURFACE MOUNT < 35 SQ. TO RD. ADAPTER, OBD. RPG work including all control wiring diagrams and interlock for system operation. CE-2 ANEMOSTAT GC5 _ 1/2" x1/2"x1/2" EGGCRATE 24x24 TEE BAR < 35 SQ. TO RD. ADAPTER. 24x24 FACE 12. Owner to provide system balance and certified report showing HR-1 ANEMOSTAT S3HOD FIXED LOUVERED FACE FLAT SURFACE MOUNT < 35 design and measured air volumes, static pressures, fan RPM s etc. _ _ _ BETTER DESIGN GROVP �.,, ARCHITECTS, INC. NOTES: HVAC LEGEND ABBREVIATIONS 7965 SW CIRRUS DRIVE 1. KITCHEN EXHAUST FANS SHALL BE ELECTRICALLY BEAVERTON,OREGON 97008 (503)574-3036 FAX(503) 574-2916_ INTERLOCKED WITH MAKE-UP AIR UNIT. VENTILATION ANALYSIS HR HIGH RETURN GRILLE 2. FOR WIRING DIAGRAM, SEE CAPTIVEAIRE DWG M-3,1, M-3.2 AIR FLOW DIRECTION 8 4 ROUND DUCT DIAMETER, INCHES SPACE SPACE SQ. PERSONS TOTAL OSA/ MINIMUM 12x8 RECTANGULAR DUCT SIZE, INCHES HS HIGH SUPPLY DIFFUSER TYPE FT. PER 1000 PEOPLE PERSON DESIGN SUPPLY OR OSA DUCT SECTION CU CONDENSING UNIT SQ. FT AT 50% OSA OSA ROUND, RECTANGULAR AUD AUTOMATIC DAMPER (CFM) NOTE 1 LE LOW EXHAUST STAMP: 208V/3PH, BY E.C. KITCHEN AREAS KITCHEN 815 20 9 15 135 1100 Ø RETURN OR EXHAUST DUCT SECTION CC COOLING COIL LR LOW RETURN �`��'� PR�FFSs ROUND, RECTANGULAR CE CEILING EXHAUST GRILLE GiNEE. i RTU-1 CR CEILING RETURN GRILLE OAD OUTSIDE AIR DAMPER �'N ti �y CIRCUIT BREAKER, BY E.C. DINING AREA - DINING 940 70 33 20 660 1000 �_ _� INTERNALLY INSULATED DUCT OSA OUTSIDE AIR , ] ��/ `� HOOD CONTROL PANEL RTU-2 '��•'�'•'•'•'�` DOUBLE LINE, SINGLE LINE CS CEILING SUPPLY DIFFUSER // I AT KITCHEN, S ELECTRICAL RAD RETURN AIR DAMPER +RE +' _ DISCONNECT E.C. ONEDWRE PACKAGE DIAGRAM EXTRA RELAY NOTE 1 FLEXIBLE EQUIPMENT CONNECTION EAD EXHAUST AIR DAMPER RF RETURN FAN e� AC-1 AC-2 MINIMUM DESIGN OUTSIDE AIR IS THE MINIMUM OUTSIDE AIR SETTING TO MAINTAIN BUILDING AIR BALANCE. �/��, 10�� r. _____ --- UNITS ARE CAPABLE OF 1007. OUTSIDE AIR AND HAVE CAPACITY TO SUPPLY THE MINIMUM OUTSIDE AIR EF EXHAUST FAN SD DUCTMOUNTED SMOKE DETECTOR c 13' S - --- r SETTINGS REQUIRED BY TABLE 403.3 OF THE IMC WHILE MAINTAINING COMFORT CONDITIONS. HR HIGH RETURN GRILLE IRr C. BARN' NC NC OUTSIDE AIR MAY BE HIGHER IF THE SYSTEM IS IN ECONOMIZER COOLING MODE. FLEXIBLE DUCT SF SUPPLY FAN EXPIRES 12/31/09 I DOUBLE LINE, SINGLE LINE OBD OPPOSED BLADE DAMPER I 1/2' CONDUIT ONLY BY E.C,, KC. SHALL PULL f ROUND TO RECTANGULAR TRANSITION 0 ROOM THERMOSTAT VD VOLUME DAMPER I LOW VOLTAGE WIRES RETURN/EXHAUST GRILLE 0 ROOM THERMOSTAT REMOTE SENSOR PER AC UNIT MFR'S / 0 INSTRUCTIONS SMOKE DETECTOR PANDA EXPRESS SUPPLY AIR DIFFUSER SD DUCT MOUNTED IONIZATION TYPE SMOKE - - X - WITH THROW DIRECTIONS TIGARD TOWN SQUARE - DETECTOR ON AC UNIT RETURN DUCT MAINS TO SHUT DOWN UNIT IN CASE OF ELECTRONIC I FIRE. SMOKE DETECTOR SHALL BE UL n' SPIN-IN WITH VOLUME DAMPER HEATING/COOLING LISTED, SFM CERTIFIED, 24 VAC, BY ELBOW WITH TURNING VANES PROGRAMMABLE ROOM 16230 PACIFIC HWY. SUITE 100 EDWARDS, DH 500 HOUSING WITH 1551F T'STAT, WALL MOUNTED ROOM T'STAT SENSOR TIGARD, OREGON @+48' WITH LOCKING Q 1, 2, , BY M.C. UNACCEPTABLE AIWA" IW RADIUS ELBOW COVER - 410 ELBOW ii R=W REMOTE SENSORS f ELBOW DOWN WITH TURNING VANES AC-1 AND AC-2 TO BE INTERLOCKED TO PREVENT SIMULTANEOUS C ;xy I HEATING AND COOLING kit r ELBOW UP WITH TURNING VANES 500 CFM M2 . 0 AC CONTROL WIRING DIAGRAM 12X12-4 NECK SIZE - NO. OF THROWS SYSTEM N.T.S. DESIGN DETAILS, LEGENDS Apo% CONSULTANTS tic. AND SCHEDULES NO 1515 SE WATER AVE. SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACTS BRUCE MYERS • • •• •• *••• • •• • • • • ••• • • •• ••• *• :• s • •• • H 10'-0" MINIMUM FROM BUILDING ELEMENTS ►I 2X4 STUD WALL W/ 5/8" TYP X H f 11111111111111 1 GYP. BD. ON BOTH SIDE - IN • •, 0 1 iiiiiiiiiiiiiii ---1-- 3/8X3 LAG SCREW TO STUD 11.140* DISCHARGE LEVEL WITH 0 t BUILDING ELEMENT IF 6" 48" ® DISTANCE IS LESS THAN MINIMUM 40'° — L 4X4 X 1/4 X 6 © 48 O.C. 101-0" � EXHAUST HOOD TRANSITION TO EXHAUST EXTEND FIRE WRAP G O FAN INLET SIZE. 0 18" ABOVE ROOF �C SEE CAPTIVEAIRE DWGS. I i // �` —I jr T C H I NEC' MIN. 12 I ROOF DECK I V I. �� IL TACK WELD --� 3" MIN. AIR SPACE PANDA RESTAURANT GROUP INC. MINIMUM 16 GAGE WHERE OFFSET IS REQUIRED. �-UL LISTED GREASE DUCT STEEL WELDED DUCT SLOPE MIN. 1/4" PER FT. FIRE WRAP INSULATION. 1683 Walnut Grove Ave. _--- --- EXTEND 18'° ABOVE ROOF. Rosemead, California '�~ 91770 1W UL LISTED GREASE DUCT ACCESS DOOR ASSEMBLY WHEN REQUIRED. Telephone: 626.799.9898 7 LOCATE IN ACCESSIBLE LOCATION -- -- — "'�'� FOR REGULAR CLEANING. Facsimile: 626.372.8288 \ (______, I DETAIL (N.T.s.) R=6 MINIMUM >< MAKEUP AIR I --MANUAL VOLUME SYSTEM FLOOR/ROOF STRUCTURE IDAMPER MIN 2"x4" A!i ideas, designs, orrongement and plans indicated PERFORATED PANEL 2—#12X1-3/4" or represented by this drawing are the property of ER ORATED SS ANEL SEE CAPTNEAIRE DRAWINGS 1/2» HANGER ROD / WOOD SCREWS Panda Express Inc_ and were created for use on �r za I 1 TO STRUCTURE, '�` this specific project_ None of these ideas, designs, DUCT WRAP SYSTEM TO BE INSTALLED » » » „ arran ants or lane m be used b or disclosed 2X2 X 1 4X2 to any person, firm, or corporation without the /�J STRICTLY IN ACCORDANCE WITH MANUFACTURERS MAX. SPACE <<�` / written permission of Panda Express Inc_ // �--� INSTALLATION INSTRUCTIONS. CLIP ANGLE 12FT ,� REMOVABLE GREASE FILTER W/ HANDLES 3" MIN. - -- / AUTO FIRE EXTINGUISHER (SEPARATE REVISIONS: PERMIT BY FIRE EXTINGUISHER CO.) ,� MTL. HOOD 22 GA. S/S PROVIDE MACHINE BOLT 48"VERIFY NUT & WASHER MTL. WALL FLASHING 24 GA_ S/S SHEET MIL. WELD -- I-•— 3" MIN. —�- 6" TYP. © ALL OPEN SIDES HOOD BY HOOD SUPPLIER o DETAIL (N.T.s_) 2x4 STUD WALL COOKING ISSUE DATE: W/ 5/8" TYPE "X" EQU I P v ENT 1ST PERMIT APPLICATION: 1/09/09 GYP. BD. ON 2ND BOTH SIDE I--- FIN. FLOOR .. •i._ • • .. . . . .,...._t *T. .:;. . .:. •,:•• . • -.,. 3RD I r . Tr Tl . . .-• ". -. _ +" ; J TRACK 4TH T ' •r • • ' ' MTL_ STUDS(TYP.) 5TH 4.. N Q cC3z 6TH SECTION OF' EXH. HOOD & DUCT(N.T.S.) ,:`'..,•2" I �.; METAL STUDS MAX. MAX.?' 16 O.C. • _ EXHAUST .... ' DUCT '• PANELS BY UNITED STATES GYPSUM DRAWN BY: BLM 9,6 ---6 •f COMPANY MIN. MIN. N c° TYPE S SCREWS © 24" O.C. CORNER BEAD t '"" • :" •" PANDA PROJECT#: S4-09-D2116 PROJECT#: 0821 / RDG0809 ••. ..•,':ti•'•. ••!. .. ..•i• • • • .•! . !' . :s, .i� 'f. . .s N.. ;_• 4. : FIRECODE C CORE 1" SHEETROCK BRAND GYPSUM LINER PANELS ARCHITECT CAPTIVEAIRE DRFA DIRECT DRIVE BY UNITED STATES GYPSUM COMPANY CENTRIFUGAL RADIAL EXHAUST FANS DIMENSIONAL DATA ASSEMBLY NUMBER : WP7008 (1 —HR) U.L. R1319, 88NK2747 R P G FAN MODEL HT W B C R RO WEIGHT LB SHAFT DETAIL (N.T.S.)PITCHED CURBS ARE AVAILABLE 7 BETTER. DESIGN GROUP DR12L/HFA 16 1/4 23 3/4 2 19 10 5/8 13 35 FOR PITCHED ROOFS. NOTE: NOTE: 30 GREASE EXHAUST DUCT INSULATION TYPE 3M FIRE BARRIER GREASE EXHAUST DUCT INSULATION TYPE 3M FIRE BARRIER ARCHITECTS, INC. SPECIFY PITCH= 12 DUCT WRAP 20A + SILICON SEALANT APPROVED DUCT WRAP 15A + SILICON SEALANT APPROVED 7965 SW CIRRUS DRIVE EXAMPLE: 7/12 PITCH = 30 SLOPE FOR 1-HOUR OR 2-HOUR STRUCTURE. FOR 1-HOUR OR 2-HOUR STRUCTURE. BEAVERTON,OREGON 97008 DRL/HFA SERIES RADIAL EXHAUST FANS FEATURES: LOCATION OF VIBRATION (503)574-3036 FAX(503) 574-2916_ - ISOLATOR-SEE DETIAL BELOW 004 0.4 _ W ROOF MOUNTED FANS CURB DIMENSIONAL DATA - UL705 'A. A/ - DISCONNECT SWITCH FAN MODEL D E ©© �''�\ t� STAMP: - STANDARD BIRD SCREEN SECURE TO UNIT WITH � �' ©a 0 PRpF - SPEED CONTROL DR12L/HFA 17 1/2 12 5/8' STUD & DOUBLE $'.tiN FJAM NUT (TYP) ii ;LNG Ef. /�/4A1 I- ,_,. 0 a OPTIONS: i di S err TABILIZER (TYP) �� �� O ` \ . = BACKDRAFT DAMPER MOUNTING FRAME OR fiiiiiiiiiii�� '• I ��� % N _ I/ HINGED FAN �� t3,1 05)HT PITCHED CURB D SCREW TD PAD CHANNEL BY UNIT MFR. , Ry C B INSULATED 4CURB - SCREW 1/2' LAG 'CAL-DYN' TYP 'RJ-C' © EXPIRES 12/31/09 I P • WITH 1'G' SEISMIC RATING ��� MIN. DEFLECTION 2.5' LEGEND LEGEND 0 0 1/4' SOUND PAD 1 TWO LAYERS 3M FIRE BARRIER DUCT WRAP 1 ONE LAYERS 3M FIRE BARRIER DUCT WRAP ROOFING • CURB "' 1 1 "' 2 FILAMENT TAPE 2 FILAMENT TAPE Ai /131 0 - 3 BANDING 3 BANDING PAN DA EXPRESS L )1N@Z. B E 1-41 -� ØGAUGE ROOF DECKiN EQUIP. MTG PAD IN 4 3—INCH PERIMETER OVERLAP 4 3—INCH PERIMETER OVERLAP TIGARD TOWN SQUARE -7_ R /� OTHER SECTION SEE 3—INCH LONGITUDINAL OVERLAP ARCH. DWG'S FOR DETAIL 5 5 3—INCH LONGITUDINAL OVERLAP -- RO 6 GREASE DUCT 6 GREASE DUCT 4, C - _ EL SPRING ISOLATOR DETAIL STRUCTION 16230 PACIFIC HWY. SUITE 100 N.T_S. FOR SL 1 INCH=25.4 MM UL # YYET—R14229 FOR SI' 1 INCH=25.4 MM UL # YYET—R14229 TIGARD, OREGON 3' FLANGE FIGURE 1 2—HOUR FIRE—RESISTIVE FIGURE 1 2—HOUR FIRE—RESISTIVE .`` PROTECTION SYSTEM FOR GREASE DUCTS PROTECTION SYSTEM FOR GREASE DUCTS 1 — HOUR OR 2 —HOUR DUCT WRAP EXHAUST FAN (RESTROOM) D ETAIL ------- —. R° R OOF OPENING DIMENSIONS M 3 •O 0 N.T.S. SYSTEM DESIGN DETAILS CONSULTANTSc. 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 503-246-0227 FAX 248-0240 CONTACT' BRUCE MYERS HOOD INFORMATION /2" DIA. HEL_VY DU-14 NUT- 1/2" DIA. ALL THREAD ROD ` 1 1- REVISIONS HOOD MAX, EXHAUST PLENUM SUPPLY PLENUM HOOD CDNFIG, RISER(S) RISER(S) HOOD CONNECTED TO ROOF JOIST ONE ABOVE AND ONE BELOW I DESCRIPTION DATE: NO TAG MODEL LENGTH COOKING TOTAL TOTAL END TO I -- - THROUGH ANOTHER HANGING ` HANGING ANGLE ANGLE `--- CONSTRUCTION ROW •tiii TEMP. EXH, CFM WIDTH LENG, DIA, CFM S.P. SUP. CFM WIDTH LEND, DIA. CFM SP, END _ 4824 10' 0,00" 12" 22" 3000 -0.675" 430 SS Q 1 H-1 600 Deg. 3000 0 LEFT ALONE ND-2 Where Exposed 4824 10' 0.00" 12" 22" 3000 -0,675" 430 SS 2 H-1 600 Deg. 3000 0 RIGHT ALONE ND-2 Where Exposed 246 10' 3'00" 430 SS *ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR 3 PSP 300 Deg. 0 2400 LEFT FRONT HANGING ANGLE IS PRE-PUNCHED AT FACTORY MISC-PSP Where Exposed **ALSO USED WITH TYPE 2 HOOD MODELS VH B & VHB-G EXHAUST RISER VOLUME ONLY 111111111 246 10 3.00 430 SS 1.00W LIGHT FIXTURES SUPPLY DAMPER N D-2. HANGING ANGLE D ETA I L 4 PSP MISC-PSP 300 Deg. 0 2400 RIGHT FRONT BULBS BY OTHERS 1/2" DIA. ALL THREAD ROD 1/2" DlA. HEAVY DUTY NUT E Where Exposed a o HANGING ANGLE CONNECTED TO ROOF JOIST ONE ABOVE AND ONE BELOW ' ' U HOOD INFORMATION -4, 2./5' ANGLE THROU ANOTHER HANGING V HANGING ANGLE II• FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE , f �. HOOD NO, TYPE QTY, HEIGHT LENGTH QTY, TYPE WIRE LOCATION FIRE SYSTEM ELECTRICAL SWITCHES HOOD 3" INTEGRATED STANDOFF ) I, �7 1 �I! :.`\r `� SYSTEM WEIGHT A \�/ ,EEn� GUARD TYPE SIZE MODEL # QUANTITY LOCATION PIPING 16' - 1'�` ���,,,�,���'' I ' ll cc14 IJ " co � ��i�i+U S EEL HANGING ANGLE Iii 0) 6 16" 20" �,., ., 1 SS Baffle with Handles 5 Incandescent Light Flxt NO NO LBS IT IS THE P 24' � � i HE RES DNSIBILITY 24 NOM � �r" 378 DF THE ARCHITECT/OWNER TO „ 23.51 OPEN LL 2 SS Baffle with Handles 6 16 20 5 Incandescent Light Fixt NO ND ENSURE THAT TH HD 16 U.L. CLASSIFIED STAINLESS STEEL LBS THE OD CLEARANCE � BAFFLE-TYPE � N . . FROM LIMITED-COMBUSTIBLE • PERFORATED PANEL o GREASE FILTERS 3 o ND 99 LBS AND COMBUSTIBLE MATERIALS �, :,IMO t *ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR Q N. IS IN COMPLIANCE WITH HANGING ANGLE IS PRE-PUNCHED AT FACTORY 1 8 LOCAL CODE REQUIREMENTS **ALSO USED WITH TYPE 2 HOOD MODELS VH1-G VH2 & VHC 4 0 ND 99 LBS 0 4 I 4 1. GREASE DRAIN ND HANGING ANG DEAIL c� °' WITH REMOVABLE CUP HOOD STYLE DIM FROM D FROM DIM FROM 41 HOOD OPTIONS REAR N FRO 1111 ill HOOD -48' H (30"H} W o Ibil ....ND, OPTION CANOPY „ = o 9'6" OILING ND2/ND2-PSP-F 4.17 2 2.25 33' MIN VERIFY WITH �, „ 0441 rn/ 48' MAX ND/ND-PSP-F 2.00 . 6.00 1 LEFT END STANDOFF (FINISHED) 3" Wide , ARCH SHEETS ,Q BACKSHELF ``28478D 2.00" . N/A it z 2 RIGHT END STANDOFF 3" Wide �' O FRONT/BACK 36"X36" 42"X42" 48"X48" � DIMS BY SIZE .r„ PERFORA TED S UPPL,Y PLENUM(S) I n VERI' AFT. WITH - �} •4 VHB/VHB G 2.25 2.25 2.25 HOOD RISER(S> ARCH SHEETS POS. LENGTH WIDTH HEIGHT VH 1/VH 1 -G 5"/9.5O" 1 1 "/9.50" 1 1 "/9.50"ND. WIDTH LENG. DIA, CFM S,P, S/S BACKPLASH, TRIM PIECES AND HANGING ANGLE LOCATIONS W 3 Front 13" 24" 6" 12" 24" 1200 0.182" CLIPS BY OTHERS.12" 24" 1200 0.18 1,4r EQUIPMENT CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: 2 SEE ARCHITECTURAL SHEETS N, 4 Front 123" 24" 6" 12" 24" 1200 0,182" FOR INSTALLATION BY OTHERS p 12" 24" 1200 0.182" INSTRUCTIONS /� y �,_,NSE C zsTE ��.._ , PA® U & 3054804-001 NFPA® 3054804-002 co CL A \ SL GAS VALV - T , , BUILDING CODES ( co 0 MATERIAL CLEARANCE REDUCTION SYSTEM T` / / 0 SECTION VIEW - MODEL 4824-ND-2 THE ANSUL GAS VALVE IS PROVIDED BY NON-COMBUSTIBLE NONE REQUIRED CAPTIVEAIRE SYSTEMS. CONTACT OUR OFFICE / WITH MISC. PSP SECTION LIMITED-COMBUSTIBLE COMBUSTIBLE 3" UNINSULATED STANDOFF WITH THE VALVE SIZE 3 DAYS IN ADVANCE OF 3" INSULATED STANDOFF WHEN IT IS NEEDED ON SITE. EXPANDED VIEW OF ND2 SECTION CLEARANCE TO COMBUSTIBLES INSTALLATION n 1. ALL ELECTRICAL "FIELD' CONNECTIONS AND RELATED W INTERCONNECTIONS BY ELECTRICAL CONTRACTORS. e--i 3,00 `` 3' UNINSULATED STANDOFF 3' UNINSULATED STANDOFF W1,1 00„ 2. ALL PLUMBING 'FIELD' CONNECTIONS AND RELATED �� INTERCONNECTIONS BY PLUMBING CONTRACTORS. (� ' I 1 3. HANGING BRACKETS LOCATED AND WELDED AS SHOWN ON `-1 F 11,00" 11.00" Q ` � PLANS, ALL OTHER HANGER MATERIALS PROVIDED BY INSTALLING CONTRACTORS. a 4. ALL CONNECTIONS FROM CAPTIVE-AIRE DUCT PER I 1.,_ 12,00 12,00° MECHANICAL CONTRACTORS'S PLANS. rn z / 5. COOKING EQUIPMENT TO SHUTOFF IN EVENT OF FIRE. V G.) 6. EXHAUST FANS TO TURN ON IN EVENT OF FIRE. O 7. ALL LIGHT FIXTURE SHOWN INSTALLED CAPTIVE-AIRE ALLED BY CAPTIVE AIRE z ARE FACTORY PREWIRED. INTERCONNECTIONS BETWEEN I Li.i I 22,00' l L ' I ' HOODS AND TO SWITCHES BY ELECTRICAL CONTRACTORS. Q 22.00 C 8. LAMPS FOR LIGHT FIXTURES BY INSTALLING 118,00" CONTRACTORS. ! �, z U.L. Listed Incandescent Light Fixture 48'00" 9. SEISMIC RESTRAINTS ARE RESPONSIBILITY OF (/J 9 U.L. Listed Incandescent Light Fixture L=) INSTALLING CONTRACTORS. `/ II . 10, INSTALLING CONTRACTORS ASSUME ALL RELATED D 0 S S S . n REPONSIBILITY FDR VERIFICATION DF DIMENSIONAL DATA CONTAINED flN THESE DOCUMENTS FOR ACCURACY, 1 A N INTEGRATION, AND ADMINISTRATION OF CODE REQUIREMENTS V 1 -9 IN EFFECT PRIOR TO ANY RELEASE FOR PRODUCTION OF V t LI -n EQUIPMENT SHOWN. ^t in BALANCE L 11. KITCHEN HOODS MUST BE BALANCED WITH KITCHEN. Q N. iri �j{ /I 1a KITCHEN SHALL BE NEGATIVE WITH RESPECT TO DINING L "+ (�j AREA. X 0 I 13. RESTAURANT SHALL BE POSITIVE WITH RESPECT TO I 0 II I 0 1 I 0 AMBIENT PRESSURE. '� /'�� _�'�� 4'�/// ADDITIONAL c.{ �� ' ��/ ��� 14. WRITTEN HOOD DIMENSIONS HAVE PRECEDENCE OVER d 7 .� SCALE.Pr. 24,00" 12.00' i 12.00' �� 12.00' '� 12.00' �` 2,4,00/' 15. SIGNED AND 'APPROVED' C❑PIES OF THIS DOCUMENT A.{ COMMENCEMENT DFIIFABRICATION.CTORY PRIOR T❑ C V / . . /ice. l Vii.. /.ii.•. , c_) 12,00 12,00 ��I " (j ` 24.00' I 24.00' -1 I 24.00' I 12.00 I I 12.00 Q_ F- I o I I 0 j I o f i 24.00 I 0 1 GENERAL NOTES RESISTANCE VS.AIRFLOW- r Kleen-Gard Baffle Type Grease Filters DATE: 1/16/2009 ,A ' 022$ 60.00" 60.00" 60.00" 60.00" - .. DWG-#: .._1 0.$ 0J5 Hood-1-899848 30,75" 61.50" 30,7 30.75'5 30,75 61,50 30,75 w z n DRAWN < 0.6 0.125 rn n 10' 0.00"Nora./10' 0.00"DD 10' 0.00"Nora,/10' 0.00"DD BY. 3,00" 3.00" 10' 3,00"Horn,/10' 3.00"OD 10' 3,00 Non/10 3.00 DD SCALE: • " ,r 0.4 0.076 Not To Scale 246.00' -u , 0.025 150/0.76 200/m 250/1.27 300/1.52 350/1.70 400/m HOOD FER QUESTIENS, CALL AIRFLOW(fpm/m/s) PLAN VIEW - Hood #1 PLAN VIEW - Hood #2 RUSTY CASE, STEVE SANKEY ALLEN PRESILDA, 6165 RESEARCH PRODUCTS ccepatimon 10' 0.00" LONG 4824ND-2 10' 0,00" LONG 4824ND-2 OR ALBERTO HERNANDEZ JR, PLAN VIEW - Hood #3 PLAN VIEW - Hood #4 17910 SKYPARK CIR STE 210, IRVINE, CA 92614 Kleen-Gard Baffle Type Filters are PHONE: (949) 660-7701 (800) 967-7701 UL Classified Grease Extracting Filters. 10' 3.00" LONG 246MISC-PSP 10' 3.00" LONG 246MISC-PSP FAX: (949) 660-7702 MEA # 168-78-M Aluminum SHEET NO- MEA # 247-96-E Stainless Steel FILTER DETAIL M3. 1 EXHA US T FAN INFORMATION - 7 REVISIONS DESCRIPTION DATE: FAN tYT UNIT FAN UNIT MODEL # MODEL TAG CFM SP, RPM H,P, 0 VOLT FLA WEIGHT <LBSJ C e n t r i f u Q t U ol Q st Belt (E Q n #1 & =2 NCA16FA (E E -1 & IF-2)) = � j�J =��- 1 NCA16FA NCA16FA EF-1 3000 1.250 1129 1.500 3 208 4,7 155,72 FEATURES: W - ROOF MOUNTED FANS D 2 NCA16FA NCA16FA EF-2 3000 1250 1129 1.500 3 208 4.7 155,72 - RESTAURANT MODEL D j - UL762 3 DD9FA DD9FA EF-3 600 0.250 916 0.250 1 115 4.8 81,98 _ - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH VENTED- WEATHERPROOF DISCONNECT RB HEATER/MUA FAN INFORMATION n - HIGH HEAT OPERATION 300°F (149°C)FAN - GREASE CLASSIFICATION TESTING UNIT FAN UNIT MODEL # BLOWER HOUSING TAG CFM S.P, RPM H,P, 0 V❑LT FLA WEIGHT (LBS,) '�` ° d ' dF N❑, n ' p ' _ 0 NORMAL TEMPERATURE TEST 20 GAUGE c� HT EXHAUST FAN MUST OPERATE CONTINUOUSLY 41 STEEL 4 A2-D,500-G15 G15 A2-D,500 MA-1 4800 0.500 1014 5,000 3 208 14,1 801,40 t TT-- , F WHILE EXHAUSTING AIR AT 300°F (149°C) CONSTRUCTION Q UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY `►,�. GAS FIRED MAKE-UP AIR UNIT(S) DETERI❑RATING EFFECTS TO THE FAN WHICH ' 00:4 NM ., If FLANGE WOULD CAUSE 3 Ii D C USE UNSAFE OPERATION, I a� •FAN INPUT OUTPUT L UNIT TEMP, RISE GAS TYPE GREASE DRAIN C1 -I NO. BTUs BTUs ABNORMAL FLARE-UP TEST IIII i NW ,- EXHAUST FAN MUST OPERATE CONTINUOUSLY w B WHILE EXHAUSTING BURNING GREASE VAPORS RO ROOF OPENING © 4 306470 281952 55 deg F Natural AT 600°F (316°C) FOR A PERIOD OF DIMENSIONS 15 MINUTES WITHOUT THE FAN BECOMING RO f . FAN OPTIONS _ DAMAGED TO ANY EXTENT THAT COULD CAUSE Z, R AN UNSAFE CONDITI❑N. FAN `'' � UNIT OPTION (Qty. - Descr,) _ G R+3 _ 2G a� I y G=R+3 OPTIONS: amca W NO. RO CERTIFIED �: GREASE BOX HINGED FAN RATIAGS W o 1 1 - Grease Box C ti SOURD I 11 ba E Fi end 2 1 - Grease Box AIR DUCTWORK BETWEEN PERfoRmiMCE Q 3 1 - I 15-BDD Damper EXHAUST RISER ON HOOD `' Iii P AND FAN (BY OTHERS) c us ,, if Oz<isr fiR 4 1 - Inlet Pressure Gauge, 0-35" mu,con T = nn�conTROt °- nssocinTion •. InTERnfTiOnnt. inc. : ic--,3, 1 - Manifold Pressure Gauge, -5 to 15" we V �t U 1 - AC Interlock Relay - 24VAC Coil gl z FAN ACCESSORIES IIIIIII 064144: N (U EXHAUST EXHAUST uy FAN FAN 6 UNIT UNIT N❑, TAG GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL Y L CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT i U?x 1 EF-1 YES o 0 co 2 EF-2 YES • 3 EF-3 YES 4 MA-1 n CURB ASSEMBLIES • NO ON CU ITEM SIZE Centrifugal 1ownb1Qst Bert (Fan =3 DD9FA (EE -3)) FAN Q 19.5 I x 19,5 �`� ON 1 # 1 Curb 26,500'W 26 500 L x 20,000 H Vented Hinged - 26.25 - C> FEATURES: i 2 # 2 Curb 26.500"W x 26,500"L x 20,000"H Vented Hinged \ - ROOF MOUNTED FANS - UL705 �' "L CURB 0 - AMCA SOUND AND AIR CERTIFIED 20 `-/ - WIRING FROM MOTOR TO DISCONNECT SWITCH Vr 3 # 3 Curb 19,500"W x 19,500"L x 12,000"H - DISCONNECT SWITCH ./P 1/1 - STANDARD BIRD SCREEN VI 411111111" REKUGE 4 # 4 Curb 31.000"W x 79,000 L x 20,000"H Insulated 25,5 I I �' — ° �:- —=-� --- - SELECTED OPTIONS: CONSTRUCTION a rz / i 3" FLANGE X 0 W 1 BACKDRAFT DAMPER ROOF OPENING 75 16 16 DIMENSIONS CS i 1::::::) ( . 75 S._ 2 l I C CS -- 12.125 BACKDRAFT DAMPER INSTALLATION • C5 O) - 16 -I AIR FLOW 21 4 BACKDRAFT DAMPER DATE: 1/16/2009 DWG.#: Fan-2-899848 L 16 1 amca DRAWN CERTIFIED BY: (ROOF OPENING) RATINGS SCALE, SQUAD Not To Scale and . > PERT OR®RRAOE FAN NOTE: UNLESS OTHERWISE STATED, PANDA RESTAURANT GROUP SHALL PROVIDE ALL c us EQUIPMENT ON THE FOLL❑WING CAPTIVEAIRE <�S mOVEmEnT SHEETS, INCLUDING: HOODS, FIRE SYTEM, nap conTROt nssoclnTlon EXHAUST FANS, SUPPLY FAN, BATHROOM FAN InTERnnTionnt. Inc. AND ELECTRICAL INTERLOCK PACKAGE SHEET NOE M3.2 • _} ELECTRICAL PACKAGES _- -I- REVISIONS -'\\ DESCRIPTION DATE: SWITCHES ROOFTOP FANS CONTROLLED _ - - At Mooular Direct-Fired Heater (Fan 44 A2 -D,500-615 (MA-1)) NO, TAG PACKAGE # LOCATION STARTERS OPTION r LOCATION QUANTITY TYPE 0 H,P. VOL 1 F__A-- - _ - (Model* SFIH-02MDF-F) Sloped Foam Filtered Intake for Size #2 Modular Heater, 26.813" Wide X 53.625" Long X 31,313" High, Includes 2" Foam 1 Light EZ Kleen Metal Mesh Filters, 1 321110AQ Wall Mount In SS Box Ship Loose With Exhaust in Fire, Relay w/ 2-DPDT on/off Exhaust 3 1.500 208 4.7 -- --- - (Model#: A2-D,500-G15) Direct Gas Fired Heated Make Up Air Unit with 15" Blower Prewire 1 Fan w/ Sup Fan (Qty2) - Down Discharge - Air Flow Right -> Left Exhaust 3 1,500 208 4.7 Suppl y 3 5000 208 141 ° d ' JF ' ' V o 82.375 53.625 CIS CD Q. Cu UD CD 16 - - - r I ° 10,8125 JOB NAME Panda Express Tigard OR C 4 9 211 S .)ATE ELECTRICAL PREWIRE PACKAGE p g O S O D 1/16/2009 `�, i' I ° DISCHARGE DRAWING NUMBER 321110AQ JOB NUMBER 899848 DRAWN BY v LJ ° OPENING CONTROL INPUT 120VAC H1=LINE, N1=NEUTRAL 15A BKR - DO NOT WIRE TO SHUNT TRIP ILL) " o 3 Phase, W/ 2 Exhaust Fans, 1 18,75 BREAKER__ 37, 75 FLEX CONDUIT --- Supply Fan, 2 Relays w/ 2 FOR FIELD 1 -DPDT On/Off w/ Supply Fan, "� WIRING H1 N1 Z FS-01 Exhaust on in fire condition I --3--- ° _e_ • BL ? • - — � {Fan Switch Shown WH m 2 .§' • (� a% �. W Al SItISltalle�_1 a � 6,125 CURB OUTER -OR Al 612 96.95 WH WALL `�J' 3 ST-2 OL-2 Label Description U o LIFTING LUGS 01.2. 0;12 Al 96 .95 WH FS Fan Switch (Lighted) 'I 8 39.5625 — 4 PLACES MS MicroSwitch (Ansul/PyroChem) V„ co R1 Relay DPDT Q E 4 LS Light Switch (1400W max) 0 ° L Hood Light(s) III Q rn GP General Purpose Relay DPDT ' SERVICE P y w TX Transformer DISCONNECT INTAKE 5 C Contactor BLOWER/ ®" SWITCH HOOD GR Ground % ILL i 36 75 ACCESS 'DIRECT FIRED `` DOOR MODULE 6 RI-i *4 rn # • BK NC • 4. • 7,8 25 �o-C-- t Z U ROOF OPENING 2" SMALLER THEN CURB EQUIPMENT 7 NO ST-3 OL-3 a.` Z 3.75 DIMENSION CURB YW Al A2 96 95 WH W••31 - 79 - • Spare Relay MS-1, MS-2 MicroSwitch Z T. 8 Contacts Ansul Pyrochem ~ NO-BL C-RD C-RD N 76.375 -, NO-BK NO-BK 2 1 NC-PR NC-BR NC-BR can 9 1 NC 3 SPARE RELAY CONTACTS 4 NO 6 CAN BE USED TO CONTROL 7 COM 9 ITEMS REQUIRING SHUT �j DOWN WHEN THE FIRE Y 10 R4 A C❑IL B SYSTEM DISCHARGES, SUCH Cu a • YW 0 WH e R1-R5 AS SHUNT TRIP, SIGNALS, 0 R3 RELAY SpaqC"Relay Contacts u JOB NAME Panda Express - Tigard DR <S4-09-D2J1�ATE JOB NAME Panda Express - Tigard DR CS4-09-D2J1�ATE 1/16/2009 \ 11 w YW WH R2-1 TERMINAL FOR FIELD O Installation Wiring 9 1/16/2009 Direct Fired Heater Wiring - ,,NO ■NC• WIRING TO BUILDING ( E") DRAWING NUMBER RP899848-4 JOB NUMBER 899848 MODEL A2-D.500-G15 DRAWING NUMBER 1/F899848-4 JOB NUMBER 899848 MODEL A2-D.500-G15 _ 0 O •C FIRE PANEL, DRY Installed Options MS-I Rl _ �, ��NO CONTACTS FOR SIGNAL � � ONLY Installed Options 12 • BK 0 Cl 6�- -''_C�NCl� BK NR-2 N�S-2 NO--0N01�9 BK R - oNO.0 C � �, o • C H • - Min ''N0.o • NO 120 V 1 PH. 240 V 1 PH. 208/460/600 V 3 PH, Discharge Temp. Control 13 _ �� C4 ��NO --- ,� E 1 N R3-1 CONTACTS NC 4-1 /'� Gal-flex Gat-flex Gat-flex - ,ENO �' C 5 & 6 ,,NO7O� • C sw-01 ST-01 OL-01 TURN ON— • conduit conduit conduit K ___ o • L1t TT1 T1 BK 14 — MIME • & OFF — !i O • (in unit) (in unit) (in unit) 2 K 4 L 4.-5-----c41--- 2 BK GR NO WITH THE NO r•^I •.$i .�, �•i ♦*1 0BK———4 061 L 3 BK MT-01 _ — �i O SUPPLY-` �i �� r'4 � ♦� .� L_--J 24V AC Interlock Relay R3-2 R4-2 GR Gom o nt Identifica son CONTACTS .„4. ♦ ♦ Component Identification 0-_———z BK 208 BK p LIGHT INPUT 120VAC H2-H5=LINE, N2-NS=NEUTRAL _ NC• NC k Disconnect * Disconnect Mr Disconnect 3 CB-01 e,s Label Descrr t�ion ocation 15 NO C 7 & 8 — ONO•o • C ^ �' Switch N Switch Switch Label Description Location B1S o p BK QTR-Of CB-01 Circuit breaker <2amp) C33 15A BKR LS-01 • TURN ON • H ■ / ■ ° BK 115 WH d _ B B�R y, BK�W_H WH — _ ._ • NO & OFF `- _i :_N❑• - H2�' -t�' B i9 _ �-- W 0 N2 t--- 1 al/ SUPPLY ■ Factory Factory I Factory 4 2 — ,, C6 .r WITH THE. p C8 �� wiring r, wiring wiring FR-01 Flame rod C163 �\ FSC-01 Fireye FSC [11-141 V ' MA-01 Modulating amplifier [193 16 O 5 Motor Type PH Volt HP FLA BREAKER MT-01 Supply motor [23 Exh-1 Exh 3 208 1.5 4.7 25 Amp /® ® ® D es ® iy it OL-01 Supply motor overload [23[73 Sup-3 Sup 3 208 5 14.1 -- Amp d- / 6 ® OL-01 ST-01 17 Exh-2 Exh 3 208 1.5 4.7 15 Amp / ( 3 PHASE 208V 0 95,130A1 96 A2 WH Customer Customer Customer PS-01 Low Airflow Switch [93 \../ /� supplied supplied supplied 7 PS-02 High Airflow Switch [93 ST-1 OL-1 / wiring from wiring from wiring from 18 - �� ,, L1 T1 T1 21 building building building INPUT _ power or pre power or pre power or pre 3 WIRE — I L2 1�T2_ 22 GR BK WH GR wired control BK RD GR wired control BK BK BK GR wired control 8 panel panel panel 3 PHASE. �, & L3 TP 3 - T3- 23 - l _o PS-02 RE-10 ST-01 Supply motor contactor [21(71(9) 19 3 PHASE 208V ai 9 S 31 BK C 01..NO BK C NC OR 0 7 C D 1 1111R -v--='--�° OR RE-10 AC Interlock Relay [103[19] ST-3 OL-3 BK NC Li T� `T1 24 NOTES CL. CZ 10 R gEa RD L2 T2 T2__ 25 GR - — Main disconnect switch [23 20 L3 T�3 ` T3 26 SUP-3 _ - DENOTES FIELD WIRING X Q TS-03 lL DENOTES INTERNAL WIRING ii 0114" TR-01 Power transformer(200va133 3 PHASE 208V WIRE COLOR ,.. TS-02 TR-02 Power transformer(20va)[12J C NC 21 BK - BLACK YW - YELLOW TR-03 Ignition transformer [143 BK°�°OR TR-04 Power transformer(20va)[17J ST-2 OL-2 BL - BLUE GY - GRAY d 12 (LINE 4) OR o Li TI T1 27 BR - BROWN PR - PURPLE �. 7 0 14 BI TS-02 High temp limit switch C103 INPUT — .� � TS-03 Intake air thermostat [103 3 WIRE - 'a �� L2 T2 T2__ 28 EXH-2 GR OR - ORANGE OR/BL -ORANGE/BLUE d 13 60 • 2 L3 T3 T3 29 - RD - RED E) BLUE/RED (STRIPE) Motor Connection 20 WH. TS-05 Discharge Air Sensor C213 PHASE_ �, �� I--- 1- WH - WHITE RD/GN - RED/GREEN 0) See above details. GY GY GY 115 WH WH DRAWING SHOWg'TEL NERGIZED -�i= / 14 0__ BIC RE-10 WH _ 3. NOTE: IF WALL MOUNT PREWIRE, OR CL TR-02 VA-01 Pilot gas valve [133 BR BL 23 FIELD INSTALLED FIRE SYSTEM '•, 24VAC Coil - Signal From Condenser BK K VA-02 Main gas valve [181 MICR❑SWITCH, THE TERMINALS SH❑WING 'Call For Cooling Interlock' 40 BR 1016 TR-03 g FACTORY WIRING MUST BE FIELD WIRED. DATE: /16/2009 ••��'•..,, 15 �}VA-01 VA-03 Modulating gas valve [203 50 }017 tS WH 1L2 • Motor Info 24 16 0 A S�BK PLUG Supply HP 5 .,.F.-1G SI? VOLTS 1 phs 208 V 18 1 1+L2 V x Box DWG #: FSC-01 CatTACT 100-C16D10 17 OOVERLOAD D 193-T1AC16 ECP-3-899848 FR-01 18 C DRAWN BR its WH BY: TR-04 YW 2, BL 19 SCALE: LO i NOTES AMPLIFIER AMPLIFIER 0 2 MINIMUM CIRCUIT AMPACITY. 18.78 Not To Scale 20 00000 0 NOTES 2 3 7 8 MA-01 ------ DENOTES FIELD WIRING DENOTES INTERNAL WIRING ECP 4 5 6 21 BL YW a WIRE COLOR VA-03 me* TERMINAL 11 PROVIDES COOLING BK - BLACK YW - YELLOW 22 010 D CONNECTION BL - BLUE GR - GREEN 02OBK WIRE COLOR BR - BROWN GY - GRAY 03o YW - YELLOW RD - RED OR - ORANGE PR - PURPLE 23 TS-05 BR - BROWN GY - GREEN PK - INK WHITE RD - RED PK - PINK WH - WHITE OR - ORANGE PR - PURPLE SHEET NO- M3.3 .� } A •. . • .. . •* • • • it.911\-- 1 le \ I \� CP-1 1:1::°;6\`■,...- •�i 16 ET_1 �- (125 CFN)!�I 10 WH-1 GR SE TANK PIPING FR ,� �PBP �- \;W -1 . 1-1 2"V �� WC-1 C 0 1-1/4 G t\ F J�2"V - - wHA--1 3/4 GW \ C I C ...'_ .r • • I I t A A ; Q A A A 1./7 1 ---- 1� f --I-- I WI I1cQ ___ ( r i ��l _ %I I- I_ ♦ HB-b �i�,� I I U „� { V i�. j11;;;:h 11 u-1 I $ ' ��i 1 _I I PANDA RESTAURANT GROUP INC. 1 HW '�� U-1 , L-1 lid-- ���FS-2 WCO L-1 - - 1 2"HWR (.4)f-i HW 1" W + N 1 _ 1683 Walnut Grove Ave. / C ( 1 ____ \\ FO-1- 14"W 2"W — --- G opilL 1 CW +� 1 Rosemead, California�- 4 HW_ \\ U I2"V EXISTING CW, I CONNECT TO EXISTING f� _ 3/ I TO OWNER PROVIDED GREASE 1 ' i t_I_ ____ Ei9 FD- " 1 1 I t- -11, / __ ___� /' __ 91770 ' ' ' ' ' , �� 12"GW /'� 1-1/2 1 1 I f " f Telephone: 626.799.9898 INTERCEPTOR, SEE SHELL I ' 1 1 1 I \ MS-1 VERIFY 1 1 41:r_f 1-1/4 CW - - - • ♦ � - r 1/2 HW ' P DRAWINGS. tit�E�l�fiI E (STING 3"GW I 4" �� �� " Facsimile: 626.372.8288 I Ill ► 1 1 , WCO LOCATION 1 ,� BALANCING VALVE, EXISTING 4"GW 1 ► I i I a .., 2-1/2"VTR •� TYP 2 1 23HWRCW ; VERIFY LOCATION (' 14 FS-1 F _1 �" �::,��.. 2 /14 S 4 GW -► �► 1 ' 1- G H B-1 rt. /4 GW C 2 W � __WCO 4"W F 3"G, IN CEILI G SPACE 11"CW c 3»G " Mo'-1____ WCO FCO EXISTING GAS - � - i---- LINE 6.5 W.C. r WM." :�.;• — __.,,,,, — ��„� ��,� r I ��� '�! CAME -GAS SHUT—OFF VALVE AT 1 " M� i of ideas, designs, arras ement and pions indicated" ,� r !► VERIFY SIZE F ■_ - _3/. HW RPBP 3/4 CW --' Panda Exprrtesss nc t and were created for use onof 1t 1 i�::.UL ��I�:F \ NO HIGHER THAT 12' OF _ , L1 m p p y g p p �r J '� W w 4. 111 Li 1, L 1 PRESSURE AND I �- - -1 FAIMI-111111 HB o fl _ this specific project. None of these ideas, designs, EXISTING 4"W ( ' I 1 I `� c I ��° HE FI 1SH D �LOOR. i _ _1 �� 3 �W � "� �� EXACT LOCATION T I_ ihre'lli� _ , TV 1 arrangements or pions may fie used by or d+scfosed VERIFY LOCATION E 1 1 1 1 .- - �.��_ _ \. 1 ! I 1 ��!,�' 1 \ to ony persn, firm. or Corporation without the 1 , 1 1 N A - - "tr t \\ WC-1 \ BEFORE I I I 1 041111L1.21111111111/%11 W A A AIA=r written permission of Panda Express Inc. -- i I es .,\ '\hkD-1 2"W CONSTRUCTION. " "''•,=' '� WC-1 WHA-1 1'It 11 -J4- I I \1 _ri 1 CW i 1 2 I I - 1 1 1"HW ` ' 1 1 ICW i II 1 I U u i �=i - -T .s WCi,o 2i GW n -1 \\ 2'"V -- - 1 2 HWR ,I ---1 • I - . , 8 1 fli a 1/2 CW 2"V gl m I REVISIONS: _ ,_J� I f -i+--L11r- +--�+ f FD_+� E. ` _ ( ! i I - e --�r L` -��� 1 13/4"CW 1 1 I 1' i 'I' t �! le --Jr- 1 1 I i' `f' 1 1 1 1 Ii 1 JI; I ' L J i 1 1 ( ( i, p 3;/4"-IW -_. J A !► V ' ' 3 I --+-- I`--+--a -1'•� 7-1._ ?'. '�:.1❑ 1 / ...� 1 `'__' _emu_,. _• I " j '----- , / irk. + I 1 --1 I I 1 1 ! _1 � (� L,. J��if' 1 - 1 I I 1 ""1 11 1 G 01 I MD Dill L ,11 T'1 I E 1 , 1 "GW 1 1 �0� - •• ; ill I 1 1 A`.f 1 ' - -'-1— • ❑� A I it I 1 l i �, 2nV •i1 ' i OA ,j . ■ 1 .' ' _ _ ! / 1 f . .----// to RrJ 31 40A _ .,r,;;.��;�.._ 1 1-1/4„(�® Iaf (i, -_ 000a30m. & 9 __L; V WCO 4AB FS-2, 1 113/4"cw" I , 40A 11 i I 3 L r 1 f -T -1 I 1 FCO r WGO 1 1 1 �.__ w =� 1 1 I , ' 1 i.--1J I I I 1 ! 1 1: I � lI � f i1 i i 1 i _ " _ ,1 � i II 11 ( 1 11 ! = 1/2HW 1 1 I I Il 1 ( [ 11 ( � _ � , r i n ,; ,i I 1; vi 2"CW 1 k 1'\ i ` " p' :3 4 W 8 ' I ISSUE DATE: 1 o - - - 3/4 W f 1 + ' 1 / j i i `� G� " 3/4W ; ; 1ST PERMIT APPLICATION: 1/09/09 f rl ■ I I , , I 1 1 I..._--- + + I 1/2 Hw BELOW 1/2'�H R I ' ' 2ND { ! 1 I , = A { r ' 1 = © �� ' ' © "��vi �+ �i 1/2"CW FL00 � �_wco r _ -+--{ r--+- wco 3 4 G �il) ��r { i = ' • m.� '.� / .!!e,.J � � �► 4TH I �' its 117 _:IL:*� in 1 Er,,�ii�.'� _ ■ _ j .. rear �1Ni :� i �' f I vf><•i l TV-1 � ° j r 1 IllrAt --,�_ 1 3ihow p\try / �.'! _r_t •n��� ,�, ry 'a� %� 5TH 1 4" •� VII i - 3/ CW 6TH © 2"V 11111F, 'S- 1,�, 4_" 1 �C NORDIN WAS " I ' /2 !, s 0, -4 1 I - /4 G �I� � � 1 + 1 " �, _�► ` � i1 � /2 i FOOT! I 4 fiD ©I�2"V {I I 1 1 G �Irb , Nfr 0 I u � . \ DRAWN BY: NLB AI U, r n / S— tiiai II _r\ \It{ ( \ f { i 1 t II c la El P 4110 IL' ��� {{ PANDA PROJECT#: S4-09-D2116 0 , { -- ! ! `�`�'i 2 " 1 PROJECT#: 0821 / RDG6809 .„ 410 H 7 2"v ;' J �� 1 t mi. .G ""' 1Lu ; ( I ice.... %� -� r { � , . I f .- 0 ,....-, , CO r-�� + { ■�..� III _ t ,ir�s� I c Ccsi K' • - .i�._ r 2-1/2"G lif1 ISH ! �{ ARCHITECT ... FCO‘, / � �� (�j r �... I ,„Hi , I I I u•Rr� .1f■f I I �' �'jam! r 1 --- 1 i 1 �� '{ / FUTURE USE 4 v Jt i 1 3 ``1i ICs , / C-2 �, .. + l 1( Pi C) r ' ,1 1,, ,--s!IJ ii1 { / i U! i; '� i R PG 9 0- i 2"VTR ---- ” /1 ���� " N.., .�____'u , � 15 MB,. �� •-- 2 /2G - -- �1 /2"V cr-v--0-0, , `tip'a � <<_,.� ' It�itt ! REITER DESIGN GROUP 1 ..� fi t�t� f / 1 , �-ollw rt,�tl_� �-, I I I tip '•/ I trrrrt► w A R H I TECTS I N C. I ' t 7 so o ANSUL VALVE© f ' I C , 1 _ I�_ j _ `�/ _ 7965 SW CIRRUS DRIVE I SHUTOFF VALVE �' 1 / BEAVERTON,OREGON 97008 1 I 1008 CFH ► ,,�� } 1 1 I M,) °� I (503) 574-3036 FAX C503)574-2916_ ---4-i ,:t10` 0 2-1/2"G ____ c' 4 ______ I , m y -iI„40 wco TV-1 STAMP: �0- PROF S I I � � GIN E�,� �o L 1 ' • � / 12 'i' A A 1 1 -- I _ , I V' 1I REGON -- )Q2' G:::-Esalt32';!09'i fr131 1 i 1 '11 1 - - - U I I [_ - - - - - - I i , .. . .� :� 1, f - - - - _ _ --I__ \ , 2 WATER AND GAS FLOOR PLAN /4” = 1 /4" = 1'-0" PANDA EXPRESS P� .o / P� .o _ TIGARD TOWN SQUARE PLUMBING PLAN NOTES g ° . 1 6230 PTIGARD, OREGON SUITE 100 111140 . Imaimpain U 1-1/4" GAS DOWN TO WATER HEATER W/ SOV. (125 CFH) 6 SEE HAVC DRAWINGS FOR FLUE. 9 CONDENSATE: PROVIDE 1" INSULATED CONDENSATE f] CONNECT HOT WATER TO TEMPERING VALVE (TV-1) TO IE SEE EQUIPMENT GAS CONNECTION DETAIL #15 ON W LOCATED ROOF HOSE BIBB NEXT TO ROOF FRAMING Vic- 9e Q 3/4" GAS DOWN TO RICE COOKER W/ SOV. (32 CFH) © COORDINATE ROUTING OF PIPE WITH HOOD AND DRAIN PIPE FROM THE EVAPORATIVE COIL IN THE PROVIDE 110 DEGREE TEMPERED WATER TO HAND DWG P-3.0. STRUCTURE TO PROVIDE MAXIMUM STABILITY_ ►• , .. © SEE ISLAND SINK DETAIL, SHEET P3.0. EQUIPMENT. COOLER. REFER TO WALK IN COOLER/FREEZER" SINK/LAVATORY. SEE WATER HEATER DETAIL SHEET P4.0.. Ed INSTALL PIPING FROM GREASE TANK THROUGH OUTSIDE 0 pa ,, A SODA CONDUIT: PROVIDE PVC CONDUIT BELOW DETAIL#3 ON DWG P-3.0. DISCHARGE TO FLOOR an GAS THROUGH ROOF TO HVAC UNITS. WALL. PIPING FOR TANK TO BE TANK INSTALLATION KIT , 4 1 GAS DOWN TO DEEP FRYER W/ SOV. (110 CFH) 8 FLOOR FROM SODA STORAGE TO SODA DISPENSER. SINK WITH AIR GAP OF TWICE PIPE DIAMETER. 1 HOT AND COLD WATER PIPE DROPS TO FOR FRONTLINE 1NTERTAIONAL MODEL 2478-NA © 1-1/2" GAS DOWN TO 91" CHINESE RANGE W/ PER DETAIL #11, ON DWG P-3.0. HEAT TRACE AS SHOWN ON DETAIL. j PROVIDE PVC WASTE AND VENT PIPING SERVING U7 ISLAND HO D COL H E 0 0 S O SERVE CONTAINMENT TANK SUPPLIED WITH THE TANK PROVIDED ISLAND SINK PROVIDE SHUTOFF VALVES. LOCATE SOV. (450 CFH) ' ® P&T RELIEF: PROVIDE 3/4" P&T PIPE FULLY INSULATED FLOOR SINK TO THE TIE-IN WITH THE NEXT VALVES IN WALL WITH ACCESS PANEL. BY THE GENERAL CONTRACTOR. COORDINATE +1 1-1/4" GAS DOWN TO 42" CHINESE RANGE w/ CONTINUE AND STOP AT 6" ABOVE TOP OF MOP SINK. DOWNSTREAM FLUSHING FIXTURE AND VENT. INSTALLATION WITH GENERAL CONTRACTOR. • 0 SQV. (190 CFH) PIPE CONDENATE DRAIN FROM WH-1 FLUE TO OVER 1 q PROVIDE TRAP PRIMER AND LINE FOR FLOOR DRAINS, BACKFLOW PROTECTED WATER FOR CHINESE RANGES. SYSTEM PLUMBING WASTE, MOP SINK. FLOOR SINKS AND TRENCH DRAINS. DESIGN VENT, WATER AND CONSULTANTS Nc. GAS PLAN 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: BRUCE MYERS ••• •• • •• • • M • •• •••PLUMBING FIXTURE SCHEDULE • •• •• • • •GENERAL PUJMBING NOTES KITCHEN EQUIPMENT SCHEDULE PLUMBING LEGEND . • • ` '�' •• Items in this schedule or their approved equivalent are Items in this schedule are furnished by the Owner & installed by the _`.t A. LANDLORD: Meet Landlord's Tenant Criteria w/ regard to Y Y -- - �- CW COLD WATER - � construction features & special requirements, etc. verify when furnished and installed by the Plumbing Contractor. Contractor & connected to the plumbing utilities by the Plumbing E,p,P q Y & how work may be performed in other spaces, where required. WC-1 TANK WATER CLOSET (Handicapped): American Standard #2168.100 Contractor (PC). PC shall install plumbing devices furnished w/ - - HW HOT WATER "Cadet 17"H Elongated pressure assisted" floor mounted, white vitreous equipment. HW=Hot Water, CW=Cold Water, R1=Rough-!n, BV= Ball - - - HWR HOT WATER RETURN • - . • 0 B. FOOD SERVICE EQUIPMENT: Refer to other portions of Plans china. Elongated siphon jet bowl. pressure assisted 1 .6 GPF. Rim 17 Valve (full port), AS=Angle Stop (chrome-plated, wheel-handle), 55:1 •& Specifications for further information about food service 1 4" a.f.f. Olsonite #95 o en front seat less cover. Tank cover lockin IW=Indirect Drain_ FS=Floor Sink, VB=Vacuum Breaker_ Where "FLEX" V VENT - (� items furnished & work performed by others. Verify rough-in / P locking is called for, provide a six foot coiled length f fl i -f - - - -�- - - -.--- • O • Y 9 p e oo c ed of flexible reinforced FV BELOW GRADE FLOOR VENT requirements w/ equipment furnished. device. Loose key angle stop. #4086.800 tank with right trip lever as •'. q / plastic tubing from the RI to the equipment, using adapters & hose O p re uired to put handle on wide side of stall. pasc ung rom e o e equipmen , usng aapers ose q P clamps as required. See Kitchen Equipment Drawings for Rough--in G G NATURAL GAS in O C. HEALTH DEPARTMENT: Comply w/ local Health Department (HD) U-1 URINAL (Handicapped): American Standards #6541 .132 "Allbrook" 1 .0" heights. / / WATER OR GAS BELOW GRADE G,A �O regulations. Omit escutcheons in food service areas. Seal pipes elongated rim. Vitreous china, Wall mounted, Siphon Jet, 1 " 4, neatly w/ grout at wall, floor, or ceiling penetrations. Omit - SERVICE COUNTER: Provide' 1 /2" HW RI at 20" a.f.f. for each --- --- GW GREASE WASTE BELOW FLOOR/GRADE r �5 insulation on exposed piping behind & under equipment. Provide GPF, 3/4" inlet spud, Flushing rm. Two wall hangers; Sloan C H � N P P P g Royal #186-1 (1 .0 GPF), RI 17" a.f.f. to rim. » --- w SANITARY WASTE BELOW FLOOR/GRADE clearance for cleaning behind &: under exposed piping as required 0 WARMING TABLES: Provide 1 " 1W valved header to FS, with by HD. Wherever possible, install all piping concealed. Conform to L-1 LAVATORY (Handicapped wall hung): American Standards #0356.015 connections to pan drains. CTG CTG CLEANOUT TO GRADE PANDA RESTAURANT GROUP INC. Y P P P 9 » » 3D � HD requirements for locations of floor sinks. Lucerne 20x18 wall hung vitreous china, front overflow, FCO faucet ledge, soap depression, wall hanger; ica o Faucet '� FCO FLOOR CLEANOUT 1683 Walnut Grove Ave. g � p P � g er-� g 4AB BEVERAGE DISPENSER: Provide 3/4" 1W from ice bin to FS. II —, II Rosemead,, California D. WORKMANSHIP shall be first class, acceptable to the Tenant & #404A-317 with 4" wrist blades; Grid strainer drain with WCO CO WCO,CO WALL CLEANOUT, CLEANOUT � Landlord. tailpiece, Chrome plated cast brass P-trap with cleanout and 1/2 CW W/BV Telephone: 626_799.9898 waste arm to wall with escutcheon, loose key angle stop �- _ SHUTOFF VALVE, BALL VALVE Facsimile: 626.372.8288 E. MAKE COMPLETE: Provide items 8c work as required to complete valves. Insulate water and waste piping under lavatory with 4 CARBONATOR: Provide 1/2"/2" CW w/ BV and stainless steel reduced PTRV PRESSURE/TEMPERATURE RELIEF VALVE the installation of plumbing systems to fixtures & equipment: pressure backflow preventer and connect to equipment as required. au es, gas & water pressure regulators, flexible t"ub"e "Handi Lay-guard" #102 kit. RI 34" a.f.f. to rim. Make connection from BV to CARBONATOR with Watts 009SS reduced I SHUTOFF V traps, strainers, g g g g � U.L.U L LISTED GAS SHUTO VALVE connections, stop valves, unions, etc. Provide & connect FD- 1 FLOOR DRAIN: Zurn # 415-B cast iron drain with 5" round nickel pressure backflow preventer. Install owner furnished water filter system. All ideas, designs. arrangement and pons indicated l u m b i n pipe from rough-ins i n t o items a s shown, specified c i f i e d & H B H B HOSE BIBB or represented Inc.this drawing are the property of plumbing P P 9 P bronze top, membrane flashing a s h i n clamp.a m . Provide 2" outlet with �i Panda Express in and were created for use on P' g P 4F WATER FILTER: Provide 1/2 CW with BV and connect to equipment as this specific project_ None of these ideas. designs. required. P-trap. Clean and polish after installation. Refer to detail. PRV PRESSURE REDUCING VALVE arrangements arty penis or plans corporation without Inc.ou oSed required. written permission of Panda Express In PROVIDE TRAP PRIMER o PIPE UP F. VERIFY LOCATIONS: Existing piping, POC shown on Drawings has 5B COLD PAN: Provide IW to floor sink. been located from information provided by others. Verify exact FS- 1 FLOOR SINK: Zurn # Z-1900-4-33-KC, cast iron 12" o PIPE DOWN locations on job site before start working. acid-resisting enameled interior, seepage pan, 12 square top 10J ICE MACHINE, AIR COOLED: Provide 1/2" CW. Provide BV and Watts with porcelain enamel loose set grate with center hole; aluminum 1 PLAN NOTE REVISIONS: G. BACKFLOW PREVENTION: Provide backflow preventers (BFP) in anti-splash inter•or dome strainer, 3" outlet. #288A VB and flex. Provide IW from bin, Cuber, Condensate to FS. P 10K See ICE MACHINE connection detail on sheet P-4.0 CI } KITCHEN EQUIPMENT IDENTIFICATION p water lines only if required by local authorities. Use devices of type Refer to detail. (vacuum breaker, double check, reduced pressure) & manufacturer FS-2 FLOOR SINK: Zurn # Z-1900-4-33-KC, cast iron body 26A)CHINESE RANGE: Provide 3/4" water line from reduced pressure DN DOWN approved by local authorities, only in locations required. acid-resisting enameled interior, seepage pan, 12" square top backflow preventor and BV to cooling water connection. Provide AFF ABOVE FINISHED FLOOR with porcelain enamel loose-set grate with center hole; aluminum 1 -1/2" gas stub with shutoff cock. Connect cold water line to AFG ABOVE FINISHED GRADE H. TRAP PRIMERS: Provide trap primers at all floor drains and anti-splash interior dome strainer, 2" outlet. faucet and gas to burner Provide 2" IW to FS. Provide 25 GPM flow floor drains. Use Precision Plumbing Products or approved equivalent Refer to detail. control fitting. Install owner supplied gas regulator (450 CFH). TYP TYPICAL A. trap pimer valve, installed in an exposed but unobjectionable location, or above the ceiling. Provide a continouous length of MS-1 MOP SINK:10" #MSB-2424 24"x24" molded stone unit with 20Q CHINESE RANGE: Provide 3/4" water line from reduced pressure SOV SHUTOFF VALVE 1/2" soft copper tube from primer to trap, sloping to trap. minimum 10 high sides, stainless steel drain body internally / PP primer P P g P• hi Faucet with integral in hank backflow preventer and BV_ Provide 1 -1/4" gas stub with shutoff VTR VENT THROUGH ROOF Provide elastomeric Insulation on pipe Installed below floor slab. cast, C cage aucet stops s s, ISSUE DATE: Use Precision Plumbing Products distribution units to connect wall brace, hose threads, pail hook, vacuum breaker; Rough cock. Connect cold water to faucet and gas to burner Provide 2" IW more than one floor sink to one primer. brass finish; Three foot rubber hose; 2" trapped and vented to FS (190 CFH). Provide 25 GPM flow control fitting. Install owner isr PERMIT APPLICATION: 1/09/09 waste connection. Provide 3/4" HW & CW RI 8" oc, 36" a.f.f. supplied gas regulator (190 CFH). PIPE MATERIAL SCH E D U LE 2ND 3RD I. WATER CONSERVATION: Contractor shall provide water flow TV-1 TEMPERATURE MIXING VALVE: Watts Model L111 , 1/2" CW & HW inlet, 1 p FRYER: Provide 1 " gas cock, for each of two fryers, Connect to SERVICE UNDERGROUND ABOVE GROUND 4TH limiting features on fixtures if/as required by local authorities. 1/2" tempered water to hand sink/lavatory. Set tem temperature to 105 5TH / P P burners w/ flexible metal gas connectors furnished by FSEC (110 CFH HARD DRAWN COPPER TUBE HARD DRAWN COPPER TUBE J. COLD WATER: Connect to domestic cold water supply Degrees_ each), install owner supplied 3/4" gas quick disconnectors COLD & HOT WATER TYPE "K" OR "L" TUBE "L" �" from civil. Provide double check and shutoff valve. route to HB-1 HOSE BIBB: Acorn #8121 with vacuum breaker, polished chrome plated. SANITARY WASTE SCHEDULE 40 ABS DWV SCHEDULE 40 ABS DWV above ceiling, suspended from structure above ceiling & down HB-2 HOSE BIBB: Woodford #RHY-2 freezeless roof h Brant with ASSE 1052 25A RICE COOKER: Provide 3/4" gas cock, Connect to in partitions, to serve fixtures & equipment_ y burner with flex connector furnished by FSEC. (32 CFH) SANITARY VENT SCHEDULE 40 ABS DWV SCHEDULE 40 ABS DWV approved backflow preventor. Route drain to over service sink, or Y . ( ) K. HOT WATER: Provide water heating stystem as shown floor sink install owner supplied 1/2 gas quick disconnect. DRAWN BY: NLB water heater. Run hot water pipe, suspended from structure HB-3 GAS BLACK STEEL, SCHEDULE 40 PiP P HOSE BIBB: Woodford #B65 freezeless with vacuum breaker, loose key • WALK-IN COOLER/FREEZER: Provide IW from DX evaporator above ceiling & walls to serve fixtures & equipment handle in recessed locking box_ coil to discharge over floor sink. Refer to detail sheet P-4.0. INDIRECT DRAIN HARD DRAWN COPPER TUBE - - go TYPE "M" L. SANITARY: Connect to sanitary waste line provided by WH-1 GAS WATER HEATER: A. O. Smith 48TH 120 or approved equivalent, PANDA PROJECT #: S4-09-D2116 civil. natural gas fired, 94% thermal efficiency meeting IBC- 1315, fully 40A POT SINK: Provide 3/4" HW & CW. Provide BV's and extend copper PROJECT#: 0821 / RDG0809 condensing, internal combustion, 60 gallon storage, 125,000 BTUH piping to faucet. Provide 2" copper piping to each compartment. FIXTURE N Pr vI hot and or cold water I es down in ut 142 GPH recove CO 100 F rise lass lined tank with anode UNIT SCHEDULE M. BRANCHES: Provide / ,p p input, recovery rise, glass tank, anode, connect to grease waste. Provide 25 GPM flow control fitting, _ in partition to serve various equipment per Kitchen Equipment burner controls, drain valve, and temperature & pressure relief valve. WATER FU SEWER FU Schedule", VEGETABLE SINK:Provide 3 4" HW & CW. ITEM FIXTURE QTY T ARCHITECT ET-1 EXPANSION TANK: Atrol ST- 12 , 4.5 Gallon tank volumn. 41 Ja / EACH TOTAL EACH TOTAL N. SODA CONDUIT: Provide conduit below floor from soda Diaphragm type, pre-charged, steel outer sheet with Provide BV's and extend copper piping to faucet. Manifold - ol ro lene liner. 41 Jb 2 waste lines from two compartments together and discharge WC 1 WATER CLOSET 2 2.5 5 4 8 storage to soda dispenser. P YP PY RPG into floor sink with air gap. Use copper pipe, fitting, L-1 LAVATORY 2 1 2 1 2 0. CONDENSATE: Provide 1 " insulated primary & secondary CP-1 HOT WATER CIRCULATING PUMP: Grundfos, UP 15-42-SF, In- line, oil and connectors, see Utility Sink detail for waste piping. lubricated, bronze body, 2 GPM at 6 feet of head, 115 Volt, 1 REITER DESIGN GROUP condensate drain pipes from fan-coil unit above ceiling to phase, 1 22 HP. Provide with timer set to normal work hours. 57B HAND SINK, WALL MOUNTED: Provide 1/2"/2" HW and CW U-1 URINAL 1 4 4 4 4 ARCHITECTS, INC. nearest floor sink. p / Provide AS and chrome-plated risers to faucet. ' FD-1 FLOOR DRAIN 4 WHA-1WATER HAMMER ARRESTER: J. R. Smith #5005 or equal. PDI size "B" Provide elbows where risers connect to faucet behind 2 $ 79b5 CIRRUS DRIVE P. CUT AND PATCH existing wall or partition as required to PDI, ASSE listed, pressurized air chamber See detail 1 , sheet P3.0 » BEAVERTO N,OREGON 97008 install new plumbing Install in accessible location with access panels where required. backsplash. Provide 1 - 1/2 vented waste. FS-1,2 FLOOR SINK 5,3 3,1 18 C503) 574-3036 FAX(503) 574-2916_ P g Provide 1 - 1/2" chrome-plated semi-cast brass RPBP REDUCED PRESSURE BACKFLOW PREVENTOR at carbonator and for P-trap with cleanout and waste arm to wall. MS-1 MOP SINK 1 3 3 3 3 Q. GAS SERVICE: Connect to 2- 1/2"G pipe provided by Landlord chinese ranges. See Kitchen Equipment Schedule for model and size at for natural gas service to this shop. Coordinate w/ gas each piece of equipment where required. Pipe discharge to floor sink. HB-1 HOSE BIBB 3 2.5 4.5 STAMP: utility company for meter requirements, permits & fees. Route 1 0 PROFFs pipe as required, suspended from structure above. Use all TD-1 TRENCH DRAIN: ZURN #Z-664-AR, 6" Wide top modular trench drain, TD-1 TRENCH DRAIN 1 3 3 �4 ENGINE`• s% welded pipe, fittings & joints in ceiling space & in wall. heavy duty slotted grate. WATER SERVICE PRESSURE • ,;�/ , ;;,. 9 P P � 9 � 9 P Y Y iron 40A POT SINK % � � `� Dura-Coated cast iron drain section with bottom outlet and seconday LOSS CALCULATIONS 1 3 3 3 3 ',// ,I/ / ..- dome strainer. Both 12" long grain module and 12" long extension MINIMUM SITE STATIC PRESSURE 55 VEG. SINK 3 6 FS ' :�' OR • module are complete with integral seepage pan and loose extra heavy 2 Pfr 1�c°c Total Fixture Units 39.5 '4'r C BARNN5 duty slotted grate. - 578 ' Design gpm Flow Rate (Flush Tank) 24 HAND SINK 3 1 3 1 3 –4.5 46 1 1 1 EXPIRES 12/31/09 Elevation Loss – 10 ft. x .433 psi FILTER SYSTEM FS FIXTURE BRANCH SCHEDULE GAS EQUIPMENT SCHEDULE Flush Valve Required Operating Pressure – psi –15 1000BTU Water Meter Pressure Loss – psi -8 (iii)) BEVERAGE DISPENSOR 1 1 1 FS FIXTURE COLD HOT WASTE VENT ITEM QTY EQUIPMENT ._._.----- CFH Double Check Valve Loss – psi –8 WATER WATER EACH EACH TOTAL 10J 400 LB ICE MACHINE 1 1 1 FS PANDA EXPRESS . Pressure Loss Available for Branch Piping – psi 19.5 WATER CLOSET (WC-1) 3/4" -- 4" 2" WH-1 1 WATER HEATER 125 125 125 Design Friction Loss – psi/100 ft 350 ft 5.5 6.1.0 800 LBICE MACHINE 1 1 1 FS TIGARD TOWN SQUARE URINAL (U-1) 1" -- 2" 1-1/2" 21D 3 DEEP FRYER 110 110 330 inc es SIZE GPM Fu VELOCITY 20A CHINESE RANGE 1 2 2 FS LAVATORY (L-1) 1/2" 1/2" 1-1/2" 1-1/4" 20 1 91"CHINESE RANGE 450 450 450 1/2" 2 1 3 20Q CHINESE RANGE 1 1 1 FS 1 6230 PACIFIC HWY. SUITE 1 00 TIGARD, OREGON 2 AND 3 – COMP SINK SEE KITCHEN EQUIPMENT SCHEDULE 20 1 42"CHINESE RANGE 190 190 190 3/4" 6 7 4 3C,D FOOD WARMER — -- 1 FS HAND SINK SEE KITCHEN EQUIPMENT SCHEDULE 1" 14 20 5 CD RICE COOKER 32 32 32 — — 1 1-1/4" 25 42 6 SERVICE COUNTER 1 1 — MOP SINK (MS-1) 3/4" 3/4" 3" 2" AC-1 1 AIR CONDITION 115 115 115 1-1/2" 38 7 8 7 413, FOR FUTURE USE 1 1 1 EQUIPMENT SEE KITCHEN EQUIPMENT SCHEDULE AC-2 1 AIR CONDITION 150 150 150 TOTAL 39.5 52 P2 • O FLOOR DRAIN (FD-1) -- -- 2" 1-1/2" MA-1 1 AIR CONDITION 350 350 350 " SYSTEM FLOOR SINK (FS-1) -- -- 3 2" TOTAL DESIGN PLUMBING LEGENDS 1742 FLOOR SINK (FS-2) -- -- 2" 1-1/2" CONSULTANTSuic. AND SCHEDULES 1515 SE WATER AVE, SUITE 400 ... PORTLAND OREGON 97214 TRENCH DRAIN (TD-1) -- ---- 3 2" 503-248-0227 FAx 248-0240 CONTACT: BRUCE MYERS • • • • • • • • : • • • • .. •• • • • • • • COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS. HOT •OR COLD . • • ••• .•' WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN P LUMBING S PECIFICATIONS _ _ 20'j 20 LONG, PROVIDE ONE WHA AT END OF PROVIDE VACUUM BREAKER VB----� 1/2" COLD WATER \ LINE BETWEEN THE LAST TWO FIXTURES. 1. THE WORK includes connection of plumbing utilities to Landlord's PROVIDE CLEANOUTS IN DISCHARGE INTO CENTER ABOVE BALL VALVE, MINIMUM ' SUPPLY DOWN IN IF BRANCH IS GREATER THAN �- utilities and installation of a complete plumbing system within the TURNS/ENDS OF PIPE. �� SIX INCHES ABOVE ICE MACHINE, 20'p p g y U S/ENDS 0 I E. ,� OF FLOOR DRAIN OR NEAR S C ES BO E CE M CH NE, PARTITION WHERE 20 LONG PROVIDE ANOTHER shop. Provide new materials, fittings, accessories, fixtures and USE DWV FITTINGS IF SIZE CENTER OF FLOOR SINK MOUNTED ON PIPE. • SHOWN ON PLAN. • + , i INSTALL PER PDI WHA IN MIDDLE, EACH SIZED equipment necessary for o complete and properly functioning system i' _ ,.�� . .i PDI I STANDARDS AND FOR HALF THE FIXTURE UNITS. 9 Y IS LARGER THAN 1 GRATE WITH AIR GAP SUFFIC ADAPTER AND SIX Fl- SIZE MANUFACTURERS -= as shown on the plans and as required. The work includes final PROVIDE FULL • p q FICIENT TO REMOVE GRATE - "A" INSTRUCTIONS. • connections to equipment and fixtures provided by others. Furnish SLOPE PIPE PORT BALL FOOT LONG 3/8" MITER THE INSULATION AT TAPE JOINTS OF FI • (P all new materials. Work shall be performed by experienced AS MUCH AS O AND STRAINER. MINIMUM SHUT-OFF VALVE REINFORCED FOOD TEES AND ELBOWS SO THAT `� � BERGLASS INSULATION. ,r- 1 i " tradesmen, and their workmanship shall be high standard, acceptable POSSIBLE GAP - TWICE PIPE DIAMETER. oN ROUGH-IN. GRADE PLASTIC THERE ARE NO GAPS AT JOINTS IF "' to the Architect, Tenant, and Landlord. . `� CUBER TUBING TO CUBER PROVIDE A ONE FOOT TOWARD POSSIBLE, THEN TAPE THEM. OTHERWISE ° ° • • II/ INSTALL WATER ' LENGTH OF NONCOMPRES- ® �• DISCHARGE. FILTER PER MAN- WATER INLET. USE FILL THE GAPS WITH BLANKET FIBER- SIBLE INSULATION AT SINGLE FIXTURE MULTIPLE FIXTURES 2. CODES: All work shall be in accordance with local codes, safety 'IV I UFACTURER'S HOSE CLAMPS AS GLASS AND PROVIDE ONE-PIECE PRE- HANGERS FOR ALL PIPE 0 0 regulations, or ordinances. Pay for any permits required, and call MAKE CONNECTION INSTRUCTIONS REQUIRED. MOULDED PVC FITTING COVERS. 2" AND LARGER. for any required inspections to be made by local authorities. TO EQUIPMENT _ FIXTURE UNIT TABULATION �,Q 44. IF FURNISHED ICE BIN o CONNECT TO CUBER PDI PIPE FIXTURE AS REQUIRED. WITH ICE MACH. AND ICE BIN DRAIN PROVIDE 1/2" UNICELLULAR ELASTOMERIC C"� REFER TO OTHER DETAILS SIZE SIZE UNIT LOAD 3. THE INTENT of the drawings is to indicate the general extent of the INSULATION ON DOMESTIC HOT AND COLD FOR TREATMENT OF INSU- FIXTURE COLD HOT T Cj VERIFY WITH LOCAL INSTALL WHERE �• OUTLETS AS REVD. � i work required for the project. The drawings for plumbing work are MAKE PIPE MINIMUM ONE SIZE ACCESSIBLE. 3/4 WATER PIPES IN WALLS AND CHASES. LATION AT PENETRATION A 1/2" 1-11 CODES WHEN TRAP '► C f•••I I N diagrammatic, showing the general location, type, piping, fixtures LARGER THAN EQUIPMENT CON- ,,,....-- REFER TO "INDIRECT MITER THE INSULATION AT TEES AND EL- OF WALLS, FIREFLOORS and equipment re required. Provide all fittings, accessories, NECTION, MINIMUM 3/4 . USE "M" AND VENT ARE RE- ID I I f+4 DRAIN" DETAIL FOR B 3/4" 12-32 WATER CLOSET 10 -- q 9 " " FLOOR BOWS. SEAL ALL JOINTS WITH ADHESIVE. FLOORS, AND FIREWALLS. offsets, and materials necessary to fulfill the intent of the " " " QUIRED FOR THE LENGTH .C'I MORE INFORMATION. C 1" 33-60 Plans. The drawings shall not be scaled for exact measurements- OR "L" HARD COPPER UP TO 1 OF DRAIN PIPE INSTALLED. -' - �' • `. "�'� •• •d,' :• ° ' • . .• •• . ' ' . ' . ° ' • '. ,• •• . �- URINAL 5 -- use dimensioned Architectural drawings. Refer to manufacturer's AND TYPE DWV FOR LARGER. FS -•-( PROVIDE FLOOR SINK AT FRONT EDGE OR SIDE D 1-1/4" 61-113 PANDA RESTAURANT GROUP INC. standard rough-in drawings for plumbing fixtures, and to EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR PROVIDE 1/2" FIBERGLASS INSULATION (2.175 R-VALUE) WITH ALL-SERVICE JACKET WITH " LAVATORY/HAND SINK 1.5 1.5 E 1-1/2" 114-154 1683 Walnut Grove Ave. Architectural drawings for exact locations. 1" CLEANING - NOT UNDER ANY EQUIPMENT. VAPOR BARRIER ON ALL COLD WATER, CONDENSATE, AND STORM DRAIN PIPE UP TO 4". , ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS PROVIDE 1" 4 35 R-VALUE INSULATION ON STORM GRAIN PIPE ABOVE 4" SIZE. PROVIDE F 2" 154-330 SINK/JANITORS SINK 3 3 Rosemead, California 4. USE ROUGH-IN DRAWINGS: Refer to rough-in drawings furnished by the REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE WHEN INSTALLED PROVIDE COLD WATER ROUGH-IN AT TOP OF ICE MACHINE. - ) 91770 Food Service E ui merit su lier, for exact location of water i in EXPOSED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES FOR ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO 1" FIBER- GLASS INSULATION WITH ALL-SERVICE JACKET ON DOMESTIC HOT WATER PIPING. supplies and drain locations t o serve Food Service Equipment P p n FURTHER INFORMATION. SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL PC TO PROVIDE WATER HAMMER ARRESTORS BY JAY R SMITH, SIOUX CHIEF, Telephone: 626.799.9898 ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. MAINTAIN VAPOR BARRIER PRECISION PLUMBING PRODUCTS OR WATTS WITH PISTON AND 0-RING not layout the work of this Section without such drawings. ON COLD PIPING BY MEANS OF SEALANT AND TAPE. FLAME-SPREAD AND SMOKE-DEVELOPED CONSTRUCTION, HAVING PDI #WH-201, ASSE # 1010 AND ANSI # A112.26.1M Facsimile: 626.372.8288 INDEXES SHALL NOT EXCEED 25/50.50. SEAL EXPOSED ENOS OF FIBERGLASS INSULATION WITH CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER 5. COORDINATE with the work of other sections and trades, with ADHESIVE MASTIC. UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. equipment furnished by others, and with the constraints of the conditions of the project site. PROVIDE ACCESS DOOR FOR SERVICING. 6. MISCELLANEOUS EXPENSES such as hook-up charges, permits, INDIRECT D ;AIN �' ICE MACHINE CONNECTIONS PIPE INSULATION WATER HAMMER ARRESTERS _ inspections, and other expenses related to a complete and NOT TO SCALE 9 All ideas, designs, arrangement and plans indicated P p P NOT TO SCALE CID or represented by this drawing ore the property of functioning system are included as port of this Section. NOT TO SCALE NTS Panda Express Inc_ and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed 7. PIPING SYSTEMS, GENERAL: All piping shall be run parallel to to any person, firm, or corporation without the building lines and supported and anchored as required to facilitate written permission of Panda Express Inc. expansion and contraction. All piping shall be concealed except in PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE unfinished spaces. Install as required to meet all construction TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP conditions and to allow for installation of other work including WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET ducts and electrical conduit. At all connections between ferrous MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED piping and nonferrous piping, provide an isolating dielectric FLOORS). PROVIDE PLASTIC PLUG IN CAST IRON BODY. union. Seal pipe penetrations of fire 'floors and firewalls with CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. 2"V REVISIONS: fireproof putty or grout. Provide Sumner or equivalent pipe hanging system in chases. Provide hangers as recommended by MEMBRANE CLAMP FLOOR SLAB ON GRADE EQUIPMENT VENT hanger manufacturer and MSS-SP-58, 69 and 89. . CEILING +... ...." ' . .. • + UNION 8. WASTE PIPING: Provide all drain, waste and sewer piping within the it .'* TEST FITTING AS REQUIRED FOR SAME SIZE AS SEWER f project space with connection to the Landlord's sanitary waste system on " � GAS EQUIPMENT REGULATOR site. All piping below floor slab and above floor shall be schedule 40 DEPTH OF SEWER ,�-UP TO 4 MAXIMUM. AS REQUIRED DWV Acrylonitrile-Butadiene-Styrene ABS plastic pipe and fittings HUB AND SPIGOT !I LONG SWEEP ELBOW AT 2"V LOOP VENT conforming to ASTM F 628-93. Plastic pipe joints will be made in a CAST IRON PIPE END OR TURN OF RUN. SHUTOFF VALVE - WA manner approved by the pipe, solvent, fitting manufacturer as an BELOW FLOOR. --.,,��...� 1,_ AGA AND UL APPROVED approved method for the intended use. All piping shall be sloped SANITARY OR STORM COMBINATION WYE ANDr,, FOR NATURAL GAS SERVICE uniformly at 2% unless otherwise requried by existing conditions. SEWER LINE EIGHTH BEND IN RUN. �' HAND SINK AT ISLAND ` ENTER TOP OF PIPE. �� 9. VENTS: Provide a complete system of vent piping consisting of schedule < = ',' ■.. I i �� < DIRECTION 6" DRIP LEG it �(�r� 40 DWV Acrylonitrile-Butadiene-Styrene ABS plastic pipe and fittings OF FLOW TEST FITTING ♦ r . conforming to ASTM F 628-93. Combine the vent risers in the ceiling TWO-WAY CLEANOUT FOR ,./ 1_1/2„,, ISSUE DATE: space and route through roof. LOCATION, SEE DWG P-1.0 10. WATER PIPING: Connect to existing water piping and provide a new LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS WCO ' CO 1ST PERMIT APPLICATION: 1/09/09 domestic hot and cold water piping system inside the building as shown on OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS I 2"W FLOOR 2ND drawings. Lay out water piping so that entire system can be drained. Hot ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. I 3RD and cold water piping shall be Type "L" copper tubing above grade, Type "K' PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. `2y LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. FOOT - tubing below grade ASTM B-88 with wrought copper fittings and sweat -17--\ 2"W 4TH connections using lead-free solder. Flush the water piping clear of debris and CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. VENT l ' 5TH clean the aerators and strainers at the termination of the installation. 2"W 6TH 11. NATURAL GAS PIPING inside and outside the building above grade shall Scnd black steel ASTM A-33 pipe with lb FLOOR CLEANOUT EQUIPMENT GAS C ISLAND VENT DETAI malleable iron screwed fittings where exposed, and welded d fittings and joints where concealed. Primer and point exterior gas piping NOT TO SCALE j NOT TO SCALE NOT TO SCALE to prevent rust. Provide all unions, shut off valves and drip legs required by NFPA-54 and governing codes. Provide all tests, inspections, hangers and appurtenances required for a complete and DRAWN BY: NLB operating system. Tap on utility gas main and gas meter shall be by gas company. Extend piping from meter to equipment as detailed on drawings. PROVIDE 1" ELASTOMERIC INSULATION STUB ELBOWS ABOVE FLOOR AT LOCATIONS ( • `'� COLUMN OR DRILL HOLE IN OVER HEAT TRACING ON CONDENSATE 12. PIPE INSULATION: Insulate all cold water and condensate piping SHOWN ON PLAN, 5" ON CARBONATOR END, PROVIDE CLEANOUT TEE SIDE OF BOX LINE (FOR FREEZER BOX ONLY) BY WALK with 1/2", and hot water piping with •I", preformed fiberglass with 5" ON DISPENSER END. WITH SCREWED COUNTER- I I I PARTITION AS SHOWN AND PROVIDE IN BOX INSTALLER, (ELECTRIC HEATING PANDA PROJECT#: S4-09-D2116 all-service jacket with vapor barrier (by CT, OC, JM, PPG, or SEAL TO CABINET WITH SILICONE. SUNK ABS PLASTIC PLUG: I I ON FLOOR SILICONE SEAL CABLE IS BY CONTRACTOR). PROJECT#: 0821 / RDG0809 Knauf). At contractor's option, plenum-rated elastomeric TAPERED-THREAD WITH J PLAN AROUND PIPE insulation (by Armstrong, Rubatex or equal) may be used. TFE JOINT COMPOUND. PENETRATION. I� I CLEANOUT 3/4" 1 -.-- DX COIL 13. SHUT-OFF VALVES with unions shall be provided at branches to groups WHERE CLEANOUT CONCEALED I TEE FACE SHALL �• of more than two fixtures, and at the water heater, to facilitate IS CONCEALED fN A BE WITHIN PROVIDE TRAP CO _ 0 I`li COORDINATE ' ' a . i • 4 •. CHASE OR PARTITION, 4" AT BOTTOM OF Y``'�isolation for repair or replacement. Use chrome-finished forged ° 4 PROVIDE A ROUND 18 I I 4 OF WALL RISER AND DIS- - ---. CO ROUTING OF ARCHITECT : SURFACE. PROVIDE CLEANOUT DRAIN WITH bronze body boll valve, with teflon seats and packing, 400 lb WOG, I I i i�i i�i�--1 { i i i i i i�i i�--iii=a i i�i i -i i I I- GAUGE STAINLESS STEEL 1 CHARGE INTO IN TURNS AND ENDS with solder ends, equal to Jenkins #902-T. Gas valves shall be all l=111_111 I-III-111-�-1 1hI-1T1-111 Tai-�-III=III-111111=1 111_111-1 COVER WITH BEVELED PROVIDE FLOOR DRAIN SHELVING IN bronze lubricated plug cocks for screwed pipe, by Walworth, I1a l l-1�a 11111 1111 11 11-1 I-I1 11111111=�11�1 I�1 I.a I Ia i I: I I PIPE EXTEN- OF PIPE. WALK-IN BOX. 9 Y I-1 I I-111=1 I I-I I l=l (11=i I I-1 11=1I 1=1 11=1 11=1 11_1 EDGES AND FLATHEAD OR FLOOR SINK 111-111 111-III^ Rockwell, Nordstrom or approved equivalent. i 1�11I 1 I I�11�I I-III 41�I I�I I-�I H I I�I 1=11 I�111 I I�I I 1�j 1� MACHINE SCREW. ( ( SIGN IF WITH AIR GAP MAKE CONNECTION 11=111=111_ 1 I II i I(I1 I li I I I I I I}I I I I1 I II I l i I I II I I I III!II I I I II II I II I1= I 11_1 I1_ I ( REQUIRED. OF TWICE PIPE TO COIL AS REQUIRED. I Ia 1 1111 •I I..„,=„ _ 14. ACCESS PANELS shall be provided in ceilings or walls where -►11-111-1 I�„111,�,1 I„III;,I ;,III„I „I!I„III„)I, ,III lit Ill_Ill_ ' : , d d Q DIAMETER_ k PG concealed control devices are located, except where access for , _ NO INSULATION ON PIPE RISER. p •��111 11111111-111.-111 I n • FLOOR fZ E i TE R DESIGN GROUP adjustment and maintenance is possible through lay-in ceilings. WALK-!N COOLER OR FREEZER BOX. ARCHITECTS, INC. CONCRETE 111 I I�I IE I I�I III I-REFER TO PLUMBING -I 11- I I, I -I 11 FLOOR i} = II_FIXTURE SCHEDULE 15. SUPPLIES AND TRAPS: Provide water sealed traps and supplies LENGTH AS REQUIRED SLAB. 111=11IFOR FURTHER 7965 SW CIRRUS DRIVE installed as close as possible to all plumbing fixtures, drains, I M III- ^ SEE FLOOR PLAN FOR RECEPTACLE LOCATION. p p g INFORMATION. BEAVERTON OREGON 97008 and food service equipment or beverage dispensing equipment items --III-III-III I P 9 _1 I I I I�' �I I I I I 1 1=111= INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX (503)574-3036 FAX(503)574-2916_ furnished by others, having a waste connection, or requiring water USE MINIMUM QUANTITY OF COUPLINGS REQUIRED, PROVIDE WCO AT BASE OF ALL RAIN-LEADER DOWNSPOUTS. Y 9 q 9 WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" SEALED WATER-TIGHT. USE LONG SWEEP service. Exposed traps and su pp lies in exposed areas (including HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY cabinet interiors) shall be chrome plated brass. ELBOWS AT BOTH ENDS, MINIMUM TWENTY FOUR INCH RADIUS. JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. AVOID ELBOWS IN HORIZONTAL RUN IF AT ALL POSSIBLE. WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. 16. INSTALLATION: Thoroughly clean items before installation. Cap CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. pipe openings to exclude dirt until fixtures are installed and STAMP: final connections have been made. Proceed as rapidly as . .) PROFF construction will permit. Set fixtures level and in proper ��'�NGINEE,Q`r4 alignment. Install supplies in proper alignment with fixtures, per ,4 y manufacturer's rough-in dimensions. Install silicone sealant %�" ;"� r between fixtures and adjacent material, for sanitary joint BELOW-GROUND SODA CONDUITEI WALL CLEANOUT WALK-IN BOX CONDENSATE DRAIN // %'' Provide clean conditions at termination of work. 1 NOT TO SCALE NOT TO SCALE „� NOT TO SCALE ORE ON 17. TEST water, gas, vent, and waste systems per local code ROOF " " v(� �I` requirements. When testing indicates materials or workmanship are 1/4 x 1-1/2 CADMIUM- GALVANIZED STEEL CLAMP. �y 1°� deficient, replace or repair as required, and repeat test till PLATED LAG SCREWS �,i' �-DO NOT CLAMP PIPE TIGHT. cgRy 13Bikikk\c' standards ore achieved. PIPE WITHOUT JOINTS " " " 4" x 6" x 12" REDWOOD CEILING-\\ IN CEILING SPACE S DO NOT INSTALL VALVES 18 x18 x1/2 THICK ROOF !�� SUPPORT BLOCK OR CCA EXPIRES 12/31/09 _� IN CEILING SPACE WALKWAY MATERIAL 18. GUARANTEE the work and the installation for one year after STEPPED FLEXIBLE PVC OR NEOPRENE COUPLING CLAMPED FOR BASE SHEET. ROT-PROOF TREATED TIMBER. formal acceptance by the Landlord and Tenant. TO FLASHING AND PIPE WITH STAINLESS STEEL SCREW CLAMPS. ("CAREY-TRED" OR Y ""Y-"'"" V-NOTCH TIMBER o�,�..--MANUAL GAS VALVE (ACCESSIBLE) PER ARCHITECTURAL PROVIDE MULTIPLE EXHAUST HOOD `�' SPECIFICATIONS.) BASE SHEETS OR AUTOMATIC SOLENOID FURNISHED GAS VALVE, RIGHT AND LEFT NIPPLE & COOPINGS ��������//�����///1�./�/�� TRIM THE TIMBER GAS PIPE HEADER ALONG WALL BEHIND PROVIDE IF NOT FURNISHED WITH \I198 CPC SEE #1211.10 ROOFING AREQUIRED TO PANDA EXPRESS KITCHEN HOOD AND COORDINATE ROOF INSULATION COOKING EQUIPMENT, APPROXIMATELY 12" REQUIREMENTS WITH EC. INSTALL ACCOMODATE ABOVE FLOOR, WITH SCREWED FITTINGS, VALVE AND COORDINATE WITH EC TO DIRECTION VARIATIONS IN SIZE AS SHOWN ON PLANS. PROVIDE OF GRAIN. ROOF DECK ROOF ELEVATION. TIGARD TOWN SQUARE QUANTITY AND SIZE OF CONNECTIONS AS WIRE. PROVIDE REQUIRED FOR EQUIPMENT BEING PIPE DROP OF SIZE AND LEAD OR j [ ,_'4- ELBOWS TO PRIMER COAT AND PAINT EXTERIOR GAS PIPE LIGHT GREEN COLOR. �'LOCATION SHOWN ON PLAN COPPER COMPENSATE SERVED. FLASHING OR ROOFING OVER FOR PIPE FLEXIBLE APPLIANCE SPUN ALUMINUM METAL FLASHING E EXPANSION. GAS LINE SUPPORT S PACING CHART 1 6230 PACIFIC HWY. SUITE 100 CONNECTOR FURNISHED DISTANCE FROM TIGARD, OREGON TYPICAL PIPE SUPPORT BASE IN BED >* BY ROOFING ANCHORED FROM WALL BY OTHERS AND INSTALLED OF MASTIC. 1 1 CONTRACTOR. • BY PLUMBING CONTRACTOR, COORDINATE ROOF SUPPORT. SPACING SLEEVE END, OFFSET .4., OR MAKE CONNECTION WITH ROOFER. I REFER TO DETAIL. PIPE SIZE MAXIMUM OR CORNER �' I S . G 0I AS REQUIRED FOR EQUIP. ----�' 1 UP TO 1 1/4" 6'-0" O.C. 2'-0'° T .•----TYPI A 6" DIRT II I I ROOF INSULATION FLOOR "�"- DIRT LEG '-' TO 6" ABOVE FLOOR II I I 1 1/2" TO 2" 5'-0" O.C. 2'-0" ROOF DECK SLEEVE ROOF is I I 2 1/2" AND UP 4'-0" O.C. 2'-0" -MANUAL GAS SHUT-OFF VALVE FOR EACH APPLIANCE �.,�� LOCATED AS REQUIRED BY THE LOCAL JURISDICTION. IF REQUIRED. ANCHOR PIPE TO ROOF DECK OR JOISTS. ROO F PIPE S U P PO RT REFER TO PLANS FOR PIPE SIZE(S) AND LOCATION(S). USE A P3 . 0 RRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. WELDED OR SCREWED FITTINGS AS SPECIFIED FOR PIPE SIZE. NOT TO SCALE MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. LOCATE PENETRATION MINIMUM 18 FROM ADJACENT WALLS. SYSTEM REFER TO KITCHEN CONSULTANTS DRAWINGS. DESIGN COOKING APPLIANCE GAS PIPE GAS PIPE ROOF PENETRATION® PLUMBING DETAILS NOT A CONSULTANTS INC. AND SPECIFICATIONS Mill 0 TO SCALE NOT TO SCALE 1515 sE WATER SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: BRUCE MYERS • •!•• •!• •• • • • « • • •• • ! •! .• • • • • • • • • •••.. •• , - - ,..-------,"---, ;/y/ 4P • _ •- )1 w , T a.' - _ _ _ . - 0 N. 0 4 G Q 4( 1/2 CW / F T CHIr1'.5 1"CW FUTURE '{" AC-2 (\ 4 3/4"CW I\ 1/2"HW ROOF (1 15 CFH) » 1/2"HWR �'"/� 1"CW , 3/4»HW 3/4"CW ' . 1-1/4"G PANDA RESTAURANT GROUP INC. ` 3 4CW / 2-1 2G ` �\ / '� / 1683 Walnut Grove Ave. .' ' <> \ /' ' 4AB 3/4"H 3 4"CW . , ,.�,. {1002 CFH) Rosemead, California MA-1 WHA-1 1 / »L�'' \ 3 G ROOF (350 CFH) 91770 �,,� � » � � • � 578 (1467 CFH) 1 Telephone: 626.799.9898 3/4' N �, 10K 1 TV-1 ( ) ,,� SHUTOFF VALVE (1002 CFH) L-1 , » Facsimile: 626.372.8288 ::> '� 2-1 2 G TV-1 , 2 G / ANSUL VALVE 2-1/2"G •' » L.,, ,.. - 10J ' 40 ' ` 3"G AC-1 {1117 CFH) 2-1 2"G 3 q CW ,i 3/4 HW » \ , (1582 CFH) / / " `� 1 CW �,ts> (115 CFH) " (892 CFH) ' , 1 CW 3/4 CW ROOF 2"G ,/ 3 4 HW 1_1/4"G. -1 4 G (442 CFH)1 / `�� / / ( ) ►. Ail ideas, desi ns. arrangement and plans indicated 3 q,"Cw 1 / ' / 1�-J" , ' ' 1-1/2"G presented by this drawing are the property of or re / `` x,176 , ,/ , �. Panda Express Inc_ and were created for use on / / 1 ( CFH) this specific project. None of these ideas, designs, 1 3/4"CW / TV-1 , ' " 578 �'' 1-1 4"G32 CFH arrangements or plans may be used by or disclosed �\, to any person, firm, or corporation without the 1 CW „ ).,(''./A(1 1 CW 1 �, 3/4 HW T. 1 / � / , / �_1 (222 CFH) • written permission of Panda Express Inc. HB-3 ' , WHA-1 .,/� WC-1 ' \ 1 20A 3"G 1"G » ” ,\`• �c.--1/2 HWR L,.'� 1/2 HWR , (1707 CFH) 1 CW 21 D 1 2CW & 1 2HW '\` FIB- .,. 20Q CONNECT TO 6.5 W.C. GAS (110 CFH) 1 (,W \ RPBP STUBOUT PROVIDE BY SHELL, 1-1/2"G REVISIONS: / ' 1»CW -.---•-BALANCING VALVLE , 1"CW ' ' VERIFY SIZE AND PRESSURE . 1"G 20A L-1 1 1"O .T.YP 2 , 1- 1-1/4"G BEFORE CONSTRUCTION. 21 D (450 CFH} TV-1 �.�, 1 G 0 U-1 ' / 1-1/4"CW \ / WH-1 21D (110 CFH} �, � \, Kf(1 2 HWR TOTAL CFH= 1707 ` (110 CFH) / " �, �/ " \ 41Jb (125 CFH) 6.5 W.C. 1-1 4»G WC-1 / SEE WATER 1-1/4 CW 1 HW \ ESTIMATED TOTAL DEVELOPED LENGTH= 270 / A HEATER DETAIL - » 20Q FOR PIPE SIZES PER 2007 OREGON MECHANICAL 3/4 G (190 CFH) CONTINUATION. CONNECT TO STUBOUT FROM SPECIALTY CODE, TABLE C402.4(2) 25A SHELL. VERIFY LOCATION OF (32 CFH) STUBOUT. ISSUE DATE: RPBP 1ST PERMIT APPLICATION: 1/09/09 4B gIAK 2ND 4F 3RD 4TH 5TH 6TH WATER RISER DIAGRAM €E SCALE Nittit GAS RISER DIAGRAM NONE 2 FIRST STUD NOT LINE CONNECTING DRAWN BY: NLB POINTS OF SUPPORT BEHIND WATER HEATER -\ �1 �,�___ IF N i 6"MAX. PANDA PROJECT#: S4-09-D2116 3 4" X 24 GAUGE PROJECT #: 0821 / RDG0809 I '\ PERFORATED STEEL 111. I \ PLUMBER'S TAPE WITH A r TINSEL STRENGHT OF 100 lit 7"MIN 1 �' POUNDS ENCIRCLING TANK 2"\/ / FRONT AND BACK. ARCHITECT : I FS-2 '' I �. N`■ I 2"VTR I� �` 2"W N• PLAN i \ / I 2"V I EXPANSION TANK \ FD-1 2 11 WCO / / 40A I / I REITER DESIGN GROUP L'-' . L-1 » \ -/ I WCO ,. FCO ,,L WCO _I - I�I _�� TIMER ARCHITECTS, INC. 2 W ■`` /`,,,,,. '�` FS-1 " 2 j 1r (TYP) THERMOMETER 7965 5W CIRRUS DRIVE —1 „VTR /2"V \. FS-1 2"FV 57B BEAVERTON,OREGON 97008 2 2 / BELOW/ \ 2"V " E 0 2"V/ fFC0 _ HWR (503)574-3036 FAX(503) 574-2916_ 3 Gw 1,, /--1 -1/2"V �' 2-1 2"V r /2"V \ / (TYP) I \ q"W 2"W / / .► FD-1 _ 2"\i,, I 2 GW FCO \ / � " �?_G G I IN-LINE RECIRC. PUMP FCO I N. '� 2"V \ + SWING CHECK VALVE �.YP �/ '\ 11 / I I U.L. LISTED FOR GAS 1 ( \ FD-1 " ( I i`'. " SHUTOFF VALVE, TYP. ci) I -- ----e L-1 I I �\ 4 w / I / 2 Gw I ,/� I T4LI1I STAMP: PROGAS EQUIPMENT _ ��„ �_1 2 , 1 WC 1 ” I2"v I R GENE s,2 W ,�J I I 3 GW I REGUTO -- F� O I WCO \ / I 2"V / )>,; 1� I I UNION, TYPICAL ;- ►; 9 /1J _ " 3 GW I I -/ 3 GW I PRESSURE/TEMPERATURE I I I ISOLATION VALVE, TYPICAL �� �' I WC 1 4 W I " I FCO 1 '/ RELIEF VALVE `j :::;;kL%..,.% 4` w �` 3 GW I 57B 2"V / ( \ I I .� FLEXIBLE GAS CONNECTION, TYP. 1 IR Ii/ " \', I ( 3"GW J PROVIDE FULL SIZE TO ' 2"W '� �/ �I � I WCO / mil✓ �°` WCO 41 Ja / ( I I OVER SERVICE SINK OR , , DRIP LEG 'y �°� 1I (TYP) I r`` 57B TD-1 I 20A FLOOR DRAIN I I Cq 13, �- ( ) FS-1 I I I FS-1 I �--- I ___,_,_ TEST FITTING 4'Y C 6p,RN MS-1 4"GW WCO �I +-- 3"GW 4 I ISLAND SINK I '�`�_ " EXPIRES 12/31/09 1/4" DIA. X 3" LAG SCREW WITH FLAT WASHER .�► I ,/ SEE HVAC DWG FOR nP. I FD 1Q FD-1 3"GW FCO 1� WCO 3"GW I " SOLID CORE PVC GAS I i (.1:0jb \ I 3 GW FLUE AND COMBUSTION 2"GW FS-1 (� AIR INTAKE. INSTALL PER �'`�-GAS FIRED WATER HEATER, SEE PLUMBING �\ I MANUFACTURERS l EQUIPMENT SCHEDULE. ''11 4"W FS-1 RECOMMENDATIONS I I PANDA EXPRESS FS-2 ' 1 rnIN, I — 4 Gw 3Gw 20Q I `. I TIGARD TOWN SQUARE 712"FV ROUTE CONDENSATE HOSE n _ , GRAIN VALVE LOCATED FOR EASY ACCESS BELOW SLAB OFF EXHAUST ELBOW TO FLOOR DRAIN. I HOSE MUST N� ( ' �) CONNECT WATER PIPING TO WATER HEATER CONDENSATE OEL US .� __ CONNECTIONS PER MANUFACTURE'S 16230 PACIFIC HWY. SUITE 100 BE BELOW EXH. ELBOW. INSTALLATION INSTRUCTIONS. TIGARD, OREGON it CONNECT TO EXISTING FLOOR ELEVATION CONNECT TO EXISTING-----' EXISTING 4"W R - I SCALE,___EXISTING 4 GW \ _._ ._._ NONE ,40:' P4 . 0% SYSTEM - SCALE DESIGN PLUMBING DETAILS WASTE AND VENT RISER DIAGRAM CONSULTANTS tic. AND RISER DIAGRAMS NONE 1515 SE WATER AVE, SUITE 400 PORTLAND OREGON 97214 503-248-0227 FAX 248-0240 CONTACT: BRUCE MYERS