Loading...
Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT Ili " 8 ' COMMUNITY DEVELOPMENT r7c - r, r Permit #: FPS2011 -00023 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718 r 43' ` "' +- Date Issued: 02/24/2011 2 1 ] Parcel: 2S113AB00600 J Jurisdiction: TIGARD Site address: 16125 SW 72ND AVE Project: Pactrust Building B Subdivision: PACTRUST BUSINESS CENTER Lot: 0 Project Description: Fire alarm. Install panel and connect to existing risers. 3/2/11, reprinted to correct address from 16150 SW 72nd Ave to 16125 SW 72nd Ave. Contractor: STANLEY CONVERGENT SECURITY SOLUTIONS IN( Owner: PACIFIC REALTY ASSOCIATES 15495 SW SEQUOIA PKWY STE 100 15350 SW SEQUOIA PKWY #300 PORTLAND, OR 97224 PORTLAND, OR 97224 PHONE: 503 - 968 -3353 PHONE: 503 - 624 -6300 FAX: 503 - 968 -3398 FEES Description Date Amount Specifics: Permit Fee - COM 02/24/2011 $86.06 12% State Surcharge - Building 02/24/2011 $10.33 Type of Use: COM Plan Review - Fire Life Safety - MF 02/24/2011 $34.42 Class of Work: ALT Type of Const: IIIB Info Process /Archiving - Sm Sheet (up to 02/24/2011 $6.00 Occupancy Grp: F -2 Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Yes Cut Sheets Required: Yes . Total $136.81 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $1,780.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law II work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance r if work i suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility otification Center. Those ules are set forth in OAR 952 - 001 -0010 through OA:.:. -I. 4090. You may obtain a copy of the rules or di ct questions to OUNC by ing 3.2 2.1987 or 1.800.332.2344. - _ Iss ed By: 7., L '' 61 Permittee ignature: Or; g Call 503.639.4175 by 7:00 a.m. for the next available inspection date. I This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. q CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT I"'! , COMMUNITY DEVELOPMENT Permit #: FPS2011 -00023 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 02/24/2011 Parcel: 2S113AB00600 Jurisdiction: TIGARD Site address: 16150 SW 72ND AVE Project: Pactrust Building B Subdivision: PACTRUST BUSINESS CENTER Lot: 0 Project Description: Fire alarm. Install panel and connect to existing risers. Contractor: STANLEY CONVERGENT SECURITY SOLUTIONS IN( Owner: PACIFIC REALTY ASSOCIATES 15495 SW SEQUOIA PKWY STE 100 15350 SW SEQUOIA PKWY #300 PORTLAND, OR 97224 PORTLAND, OR 97224 PHONE: 503 - 968 -3353 PHONE: 503 - 624 -6300 FAX: 503 - 968 -3398 FEES Description Date Amount Specifics: Permit Fee - COM 02/24/2011 $86.06 12% State Surcharge - Building 02/24/2011 $10.33 Type of Use: COM Plan Review - Fire Life Safety - MF 02/24/2011 $34.42 Class of Work: ALT Type of Const: IIIB Info Process /Archiving - Sm Sheet (up to 02/24/2011 $6.00 Occupancy Grp: F -2 Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Yes Cut Sheets Required: Yes Total $136.81 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $1,780.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. ou may obtain copy of the rules or direct questions UNC by calling 503.232.1987 or 1.800.332.2344. Issued By: L — - Permittee Signature: all .� 4175 by 7:00 a.m. for the next available inspect n date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System !� FOR OFFICE USE ONEY 1,11 City of Tigard l itZl y : (/ tl mr f 9.d /- 3 Permit No > �`� - • 13125 SW Hall Blvd., Tigard, OR 97223 () \1 Plan Review Phone: 503.639.4171 Fax: 503.598.1/61.5 � 3 Date/By: �f►./ � rs",� Other Permit: TI G A R D Inspection Line: 503.639.4175 Date Ready/By: luris: H See Page 2 for Internet: www.tigard Notified/Method: err Supplemental Information 4 �. t3 Y� �,,fl ; , W >;, �, A k d 3� r ,.. ,.. �,,w , 1 ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the e > work indicated on this application. ❑ 1- and 2- family dwelling ® Commercial/industrial Valuation: $ ❑ Accessory building ❑ Multi - family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: 1° Total number of floors: Job site address: 16150 SW BO 1 ►I.. "' •i• RD -7L /4-t) New dwelling area: square feet City/State /ZIP: PORTLAND, OREGON 97224 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: PACTRUST BLDG B Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Subdivision: ( Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this a lication. INSTALL AFA PANEL, CONNECT TO EXISTING RISERS Valuation: !1 . j — 7 re • Existing building area: square feet New building area: 1,797 square feet a 1;) Q+ T I t r3 t �,� Number of stories: Name: PACIFIC REALITY ASSOCIATES Type of construction: Address: 15350 SW SEQUIOA PARKWAY Occupancy groups: City/State /ZIP: PORTLAND, OREGON 97224 Existing: Phone: ( ) Fax: ( ) New: S a � . ,r x . x .«..�- .,- ....,.. ..,.« Business name: STANLEY SECURITY SOLUTIONS All contractors and subcontractors are required to be Contact name: GARY TAUSCHER licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 15495 SW SEQUOIA PARKWAY jurisdiction in which work is being performed. If the City /State /ZIP: PORTLAND, OREGON 97224 applicant is exempt from licensing, the following reasons apply: Phone: (503) 968 -3355 I Fax: : (503) 968-3398 E -mail: GTAUSCIER @STANLEYWORKS.COM ��* .1" +; BUILDING PERMIT FEES* " Business name: STANLEY SECURITY SOLUTIONS (Please refer to fee schedule) Permit fee: Address: 15495 SW SEQUOIA PARKWAY State surcharge (12% of permit fee): City /State /ZIP: PORTLAND, OREGON 97224 0 FLS plan review (40% of permit fee): Phone: (503) 968 -3355 Fax: (503) 968 -3398 (Due upon application.) CCB lie.: 161567 Total permit fees: /34 ! Amount received: Authorized signature: � ' , � , � This permit application expires if a permit is not obtained Print name: GARY TAUSCHER Date: 2/23/2011 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Service Board. I:\ Buildin g\Permits\PPS- PermitAppdoc 03 /23/06 440- 4613T(11 /02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information � . 6 � _._?s .... .�".,:.._ ,c_� m:.*.. 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ❑ 1 -10 heads: No plan review required. ® Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: _ Additional description of work: 3 F ". l)aeaaaE t a ", l)1oS`e1` f . ❑ Wet ❑ D Additional Stand! i • es Information: Hazard Grou! Densi Des' Area K. Factor S ! rinkler Pro'ect Valuation: $ Hood Project Valuation: $ ...i�. x....c.,...ua,. .. G. ., ..aa. �� E-. ix s:+wmAm � .�• �. �.r- x.a- 9ei�� s,C,,. <.?H:1xL+ %$�, .• w..e,:...v ....,sru�.�+• ' "..m..9u.,s:. a.s..w�.v $m'_, w,.b, .0 x,n4 ..v- sb.&3`u.un« Submittal shall Batte Calculations ❑ Yes include: Individual Component ® Yes Cut Sheets Fire Alarm Project Valuation: 11 ,, g y a 1lde9'`�t ir�tfe2w�aKxe`i S• uare Foota e: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and eater $381.50 Sprinkler Project Square Footage: sq. ft. - M1arn Project valuation subtotal see A, B & C above : $ Permit fee based on .ro'ect valuation see fee schedule : $ Permit fee based on s • uare foota • - see D above : $ State Surchar•e 12% of .ermit fee : $ an ' eview 40% o • ermit eel $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. C: \Documents and Settings \gmt1026 \My Documents \ Permits \FPS - PermitApp PACT 8 - IAMROCK 18333 BOONES FERRY.doc Fr5Zo 1( —o0 Oz3 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Pactrust Building B Address: 16125 SW 72 Ave Description of property: PacTrust Occupancy type: Name of property representative: Dennis Pagni Address: 15350 SW Sequoia Parkway #300 Phone: 503 - 624 -6300 Fax: E -mail: Authority having jurisdiction over this property: City of Tigard Phone: 503 - 639 -4171 Fax: E -mail: 2. Fire Alarm System Installation, Service, and Testing Information Installation contractor for this equipment: Stanley Convergent Security Solutions Address: 15495 SW Sequoia Pkwy Ste. 100, Portland, OR 97224 Phone: 5039683300 Fax: 5039683397 E -mail: Service organization for this equipment: Stanley Convergent Security Solutions Address: 15495 SW Sequoia Pkwy Ste. 100, Portland, OR 97224 Phone: 5039683300 Fax: 5039683397 E -mail: Location of as -built drawings: Location of Historical Test Reports: Location of system operation and maintenance manuals: A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company: Stanley Convergent Security Solutions Address: 15495 SW Sequoia Pkwy Ste. 100, Portland, OR 97224 Phone: 5039683300 Fax: 5039683397 E -mail: Contract expires: Contract number: Frequency of routine inspections: 3. Type of Fire Alarm System or Service NEPA 72' Chapter Reference of System Type: Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: Stanley CSS Phone: 8778990001 Supervisory: Stanley CSS Phone: 8778990001 Trouble: Stanley CSS Phone: 8778990001 Entity to which alarms are retransmitted! Phone: Method of retransmission of alarms to that organization or location: NFPA 72, Fig. 4.5.2.1 (p. 1 of 5) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. If Chapter 8, note the means of transmission from the protected premises to the central station: ❑ Digital alarm communicator ❑ McCulloh ❑ Multiplex ❑ 2 -way radio ❑ 1 -way radio ❑ N/A If Chapter 9, note the type of connection: ❑ Local energy ❑ Shunt ❑ N/A 3.1 System Software Operating system (executive) software revision level: Site - specific software revision date: Revision completed by: 4. Signaling Line Circuits Characteristics of signaling line circuits connected to this system (see NFPA 72 Table 6.6.1): Quantity: 0#6 Style: c.5-0,,t/ /9L6/4r Class: 5. Alarm- Initiating Devices and Circuits Characteristics of initiating device circuits connected to this system (see NFPA 72 ® , Table 6.5): Quantity: 7V0 Style: 1 d- 5 Class: 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: 0/V- Type of devices: ❑ Addressable pa Conventional ❑ Coded ❑ Transmitter El N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 0 A/6 Type of coverage: ❑ Complete area ['Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: ❑ Addressable gt Conventional ❑ Coded ❑ Transmitter ❑ N/A Type of smoke detector sensing technology: ❑ Ionization g Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: Type of coverage: Type of devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A Type of smoke detector sensing technology: ❑ Ionization ❑ Photoelectric 5.2.3 Heat Detectors Number of heat detectors: Type of coverage: ❑ Complete area ❑ Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: ol/✓C Type of devices: ❑ Addressable Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: ❑ Enabled ❑ Disabled ❑ Set for seconds 6. Supervisory Signal Initiating Devices and Circuits 6.1 Sprinkler System Number of valve supervisory switches: 73✓ Type of devices: ❑ Addressable Wonventional ❑ Coded ❑ Transmitter ❑ N/A NFPA 72, Fig. 4.5.2.1 (p. 2 of 5) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 6.2 Fire Pump Type of fire pump: ❑ Electric ❑ Diesel Type of fire pump supervisory devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A Fire Pump Functions Supervised ❑ Fire pump power ❑ Fire pump running ❑ Fire pump phase reversal ❑ Selector switch not in auto ❑ Engine or control panel trouble ❑ Low fuel Other: • 6.3 Engine- Driven Generator Type of generator supervisory devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A ❑ Engine or control panel trouble ❑ Generator running ❑ Selector switch not in auto ❑ Low fuel Other: 7. Annunciators 7.1 Annunciator 1 ❑ Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 7.2 Annunciator 2 ❑ Local . ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 7.3 Annunciator 3 ❑ Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 8. Alarm Notification Devices and Circuits 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: Number of multiple voice alarm channels: - Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: (94/.6- Number of telephone handsets stored on site: Type of telephone system installed: KElectrically powered ❑ Sound powered ❑ N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system (see NFPA 72 Table 6.5): Quantity: 6/ Style: - Class: 8.4 Types and Quantities of Nonvoice Notification Appliances Installed v / /� Bells: //a Ir /7 G With visual device: Horns: With visual device: Q/vf Chimes: With visual device: Bells: • With visual device: Visual devices without audible devices: Other (describe): • NFPA 72, Fig. 4.5.2.1 (p. 3 of 5) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 9. Emergency Control Functions Activated ❑ Hold -open door releasing devices ❑ Smoke management or smoke control ❑ Door unlocking ❑ Elevator recall ❑ Other 10. System Power Supply 10.1 Primary Power Nominal voltage: 1A 0 V '/ /� A G Amps: 2 0 Overcurrent protection: Type: Ca eel/ r ffaF F,/l Amps: 0 Location (of primary supply panelboard): L LD �, , C • Disconnecting means location: 10.2 Secondary Power Location: Type: Nominal voltage: Current rating: Number of standby batteries: 7tt/ Amp hour rating: 7, Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: 2 Y In alarm mode: • 11. Record of System Installation Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) NFPA 72 ® NFPA 70 760 ❑ Manufacturer's published instructions ❑ Other (please specify): System deviations from referenced NFPA standards: Signed: Printed name: Ken Craft Date: 4/21/2011 Organization: Stanley CSS Title: Fiels Service Technician Phone: 503 - 968 -3300 12. Record of System Operation All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: NFPA 72 ❑ NFPA 70 Article 760 ❑ Manufacturer's published instructions ❑ Other (please specify): ❑ Documental n 'n accord ce with nspection and Testing Form (Figure 10.6.2.3 of NFPA 72 is attached Signed: f Printed name: Ken Craft Date: 4/21/2011 Organization: Stanley CSS Title: Field Service Technician Phone: 503 - 968 -3355 NFPA 72, Fig. 4.5.2.1 (p. 4 of 5) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. r ■ 13. Certifications and Approvals 13.1 System Installation Contractor This system as s ec•fied her�ei has been installed and tested according to all NFPA standards cited herein. Signed: / Printed name: Ken Craft Date: 4/21/2011 Organization: Stanley CSS Title: Fiefs Service Technician . Phone: 503 - 968 -3300 13.2 System Service Contractor This system as spe •f d herein has been installed and tested according to all NFPA standards cited herein. Signed: er rinted name: Ken Craft Date: 4/21/2011 Organization: Stanley CSS Title: Field Service Technician Phone: 503 - 968 -3300 13.3 Central Station This syste specified herein will be m ed according to all NFPA standards cited herein. Signed: tilts V) Printed name: Gary Tauscher Date: 4/21/2011 Organization: Stanley CSS Title: Operations Manager Phone: 503 - 968 -3355 13.4 Property Representative I accept th• system as h ng been installed and tested to its specifications and all NFPA standards cited herein Signed: Printed name: 6 -v C,C Lick Date: 4 ( a -20'I Organization: J I^v 7 Title: ee 6 f Q • is/ ,/1 i- . Phone: (5' J ) ‘ y ' 7 > 13.5 Authori . Having Jurisdiction I have witn ed a satisfactory acce.. ice test of this system and find it to be installed and 'operating properly in accordance with its ass ved plan . . sr -cifications, its approved sequence of operations, and with all NFPA standards ited herein. Signed: , 1 ) Printed name: r ' 7r Date: 0.6 f Organiz.tion: & t Title: f›, , Phone: i !__ NFPA 72, Fig. 4.5.2.1 (p. 5 of 5) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution.