Loading...
Plans 2006 ROOFING MATERIALS AND SYSTEMS DIRECTORY ' 70 ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU) Continued Roofing Systems (TGFU) Continued Foam: Resin Technology "RT- 2031 ", 1 -1/2 in. thick min. brane), utilizing any of Carlisle's membranes, can be surfaced with two coats Base Coat: "Mult -I -Therm 500 ", at 1 -1/2 gal /sq. of "Sure -Seal Acrylic Coating" at a max 1 -1/2 gal /sq /coat and improve it's • Top Coat: "Mult -I -Therm 600 ", at 1 -1/2 gal /sq. slope up to a max 2 in. slope. OTHER SYSTEMS A membrane assembly, utilizing any of Carlisle's membranes, can be 1. Deck: NC Incline: Unlimited surfaced with two coats of "Sure -Seal Acrylic Coating" at a max 1 -1/2 Insulation: Any UL Classified, any thickness. gal /sq /coat and maintain the slope of the uncoated assembly Membrane: "CCW- 707 ", "CCW -701P" (modified bitumen), self Unless otherwise indicated in the systems described below, any adhesive adhered. splice may be overlaid with pressure- sensitive flashing. Surfacing: Any UL Classified steel roofing panel, installed in accor- "Sure -Seal FR EPDM ", 90 mil is an acceptable alternate to the 45 and 60 . dance with the manufacturer's installation instructions. mil thick "Sure Seal FR EPDM" in any applicable Classification. Any UL Classified United Solar Systems Corp Photovoltaic (Solar) Module CARLISLE COATINGS & WATERPROOFING INC R15066 System may be installed over any UL Classified Carlisle roofing membrane 900 HENSLEY LN, WYLIE TX 75098 assembly that utilizes gypsum board, provided that the roofing membrane • ' SINGLE PLY MEMBRANE SYSTEMS is applied directly over the gypsum (either adhered to, mechanically fas- Class A - Ballasted tened over or loosely -laid over the gypsum). The Module system is either • 1. Deck: NC Incline: 2 self- adhered directly to the roofing membrane in the field or self- adhered to Membrane: One or more layers of either "CCW MiraDRI 860/861 ", an intermediate roofing material layer in the factory and then attached to "Firestone /SBS /SA" or "Firestone /MB /SA" (modified bitumen) self- the roofing membrane in the field using liquid adhesive, tape adhesive or adhering or "CCW-500R" applied as a hot fluid coating. fasteners. The Classification applies to combustible and non - combustible decks. Any UL Classified insulation, any combination, any thickness, may Insulation: Dow Chemical Co.'s "Styrofoam RM ", U.C. Industries be installed below the gypsum. The maximum incline and Classification "Foamular 150, 154, 250, 254 or 404" or Amoco Foam Products Co.'s (Class A, B or C) shall be in accordance with the Classification established "Amocor P84, P86, P864, PG38 or PG39 ", any thickness laid loosely. for the membrane roofing assembly, however the incline can not exceed • Scrim (Optional): Roofing fabric. 1- 1/2:12. Surfacing: Crushed stone (1/2 to 3/4 in.) at min. 600 lbs. /sq. ft. or For Combustible Decks: A minimum 2 in. thick layer of Carlisle Polyiso • • concrete pavers, min. 6 lbs. /sq. ft. HP -WLC or Atlas AC Foam III is placed directly over a combustible deck . and is covered with any Carlisle roofing membrane used in any of the fol- . , CARLISLE SYNTEC INCORPORATED R8103 lowing minimum Class B assembly listings to achieve a Class B fire Classifi- 1285 RITNER HWY PO BOX 7000, CARLISLE PA 17013 cation. As an alternative, any UL Classified insulation (except expanded or SINGLE PLY MEMBRANE SYSTEMS extruded polystyrene), any combination, any thickness, may be used below j In the fully adhered and mechanically fastened systems described below, the the Polyiso FIP -WLC or AC Foam III 2 in. minimum thickness layer. All I "Sure -Seal EPDM" membrane coated with "EM -8 Hypalon" coating at 2/3 insulation joints must be staggered a minimum of 6 in. from the deck joints gal /sq and dry silica sand (35 lbs /sq) may replace the "Sure -Seal FR EPDM" or from the insulation joints below. The maximum incline shall be in accor- i • or "Sure-Seal FR -PLUS EPDM" membrane. dance with the Classification established for the membrane roofing assem- b When a classification does not require a hypalon or hypalon and sand bly, however the incline can not exceed 1/2:12. • coating, the classification of any EPDM roofing system is retained when Unless otherwise indicated, Classifications for "Sure -Flex PVC" include 50 • surfaced with 1 or 2 coats of "EM -8 Hypalon" coating using of coverage rate mil, 60 mil and 80 mil thick membranes. For adhered "Sure -Flex PVC" of 2/3 gal /sq /coat limited to max 3 -1/2 in. slope. assemblies, the membrane is adhered with Carlisle "PVC Bonding Adhe- I, Unless otherwise indicated, when referring to gypsum board in the follow- sive" at 45 to 65 ft /gal. i ing classifications, the following will be referenced: G -P Gypsum DensDeckOO, Unless otherwise indicated Atlas Roofing "FR 50" is an acceptable alter- , 1/4 in., Regular gypsum board (not Classified) laid with staggered joints (6 in. nate for the "FR Base Sheet" at a maximum incline of 1 -1/2 in. offset) measuring 0.463 in. thick min and weighing 184 Ibs /sq min or Georgia Class A - Ballasted .4: . Pacific "Sound Deadening" Board, measuring 0.208 in. thick min and weighing Unless otherwise indicated in the systems described below, the insulation 109 lbs /sq min. and the membrane are laid loosely and surfaced with river bottom stone, nom q 1/4 in. thick (min) G -P Gypsum DensDeck®, V4 in. thick (min.) Owens 1 -1/2 in. diam, at 1000 lbs/sq min. Suitable alternates are size Nos. 1, 2, 3, 4 Corning Strataguard or regular gypsum board may replace "HP Recovery and 24 (as per ASTM D448), also at 1000 lbs /sq min. In addition, concrete Board" in any existing noncombustible deck Classification. When this is done, pavers or crushed stone may be used. Pavers must weigh 1000 Ibs /sq min and t i. he resulting roofing system is acceptable for use over combustible (15/32 in. spaced no more than 1/8 in. apart and the crushed stone must meet the above min) roof decks. The joints in the gypsum board are offset 6 in. with the joints size and weight requirements. Carlisle HP Protective mat (not Classified) in the deck. weighing,4 oz /sq /yd may be used between membrane and ballast, insulation •; 1/2 in. thick (min) gypsum board, '/4 in. thick (min.) Owens Corning and ballast (Irma System) or membrane and deck. Membrane splices, 3 to 4 in. Strataguard or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in wide are adhered with "Sure -Seal EP -95 Splicing Cement" at 130 to 150 lin .s'4. any existing noncombustible deck Classification. When this is done, the ft /gal and may be sealed with "CCW -704 Mastic "; .•,l resulting roofing system is acceptable for use over combustible (15/32 in. min) Before the splice is assembled, a 3/16 in. bead of "Sure -Seal In -Seam Sealant" A roof decks. The joints in the gypsum board and overlayment board are offset or "Sure -Seal In -Seam Sealant 1124" is applied to the seam area. Splice edges R; s.. 6 in. with the joints in the deck. are covered with "Sure -Seal Lap Sealant" at 11 oz /22 lin ft. • ..ti ,: Unless otherwise indicated, Johns Manville "ENRGY 2 Plus" (composite) Unless otherwise indicated, any of the reinforced membranes ( "Sure -Seal . insulation may replace the ' HP Recovery Board" over polyisocyanurate Reinforced EPDM ", "Sure -Seal FR Reinforced EPDM" or "Sure - Tough ") may 4 insulation in any of the systems mentioned below. be substituted for the membrane described in the following ballasted systems. Unless otherwise indicated, any UL Classified wood fiber board may replace Unless otherwise indicated in the systems described below, "Sure-Seal "HP Recovery Board" in any of the systems mentioned below. SecurTapeTM ", or " Sure -White SecurTapeTM Splice Tape ", 3 to 11 in. wide, may Straight or tapered insulation may be used in the following assemblies be used in any Classification where a black or white EPDM membrane is *" provided they do not exceed the indicated incline or thickness and carry a UL specified, respectively . An appropriate primer may be used to clean mem - label. brane surface. '' Unless otherwise indicated, the term "Referenced Insulations" will include Unless otherwise indicated in the systems described below, any completed .; , the following.. Carlisle "Polyiso HP ", "Polyiso HP -H ", "Polyiso HP -W ", splice may be overlaid with pressure- sensitive flashing. :4 'Polyiso HP R" 'Polyiso HP- WLC ", "Polyiso HP -HCG" or "Polyiso HP -N ", Unless otherwise indicated, any UL Classified Carlisle membrane may be -i Atlas Roofing "ACFoam Il" or "ACFoam III ", Dow "Hy -Therm AP ", Hunter utilized in the ballasted assemblies described below. ;' >, :: ; .( ti Panels "H- Shield ", Johns Manville "ENRGY- 2 ", or ' ENRGY -3 ", Firestone 1. Deck: NC Incline: 2 :€ Building Products "ISO 95 +GL ", "GW" or "HF ", Rmax "Multi-Max ", any Insulation: Any UL Classified insulation, any thickness, any combina- i : thickness. • Sure Tough" membrane may be used in lieu of "Sure -Seal Reinforced Membrane: "Sure -Seal EPDM ", 0 or 0.060 in. (System Designation ;,, EPDM" membrane in any of the following systems. - "Weather Bond Pro(TM) 101 Rubber Roofing Membrane" may be used in Design B.) i ' lieu of "Sure -Seal EPDM" in any applicable Classification. 2. Deck: C-15/32 Incline: 2 ;rn, Membrane: "Sure-Seal EPDM", 0.045 or 0.060 in. (System Designation Sn ation 1 :v Seal EPDM " S "Weather Bond Pro(TM) 310 Multipurpose Lap Sealant" may be used in lieu :� of "Sure -Seal® Lap Sealant" and "Weather Bond Pro(TM) 121 Rubber Roofing - Design B.) Adhesive" may be used in lieu of "Sure -Seal® 90 -8 -30A Bonding Adhesive" in 3. Deck: C -15/32 incline: 1 ^' any applicable Classification. Insulation: 3/4 in. min perlite over 1/2 in. min wood fiber; 3/4 in. min ?s„ A membrane assembly, (without polyisocyanurate directly below the mem- perlite over 1/2 in. min wood fiber over 5 in. max polystyrene. •'f;"i -' LOOK FOR THE UL MARK ON PRODUCT ,•% 2006 ROOFING MATERIALS AND SYSTEMS DIRECTORY 76 ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) ' Roofing Systems (TGFU) Continued Roofing Systems (TGFU) Continued Membrane: Any UL Classified Carlisle EPDM membrane. combination, any thickness, cellular concrete, precast concrete with 4. Deck: C -15/32 Incline: 1 grouted joists or structural (poured -in- place) concrete. Insulation: Carlisle HP Recovery Board or any UL Classified wood Membrane: "72 mil Sure -Weld EXTRA" or "80 mil Sure -Weld EXTRA" fiberboard, 1/2 in. thick min. 13. Deck: NC Incline: 1/2 Membrane: Any UL Classified Carlisle EPDM membrane. Insulation: See: "Referenced Insulations ", any combination, any thick - Class A - Mechanically Fastened (T P 0) ness. 1. Deck: NC Incline: 1/2 Membrane: "72 mil Sure -Weld EXTRA" or "80 mil Sure -Weld EXTRA ". 14. Deck: NC Incline: 1/2 Insulation: See "Referenced Insulations ", any combination, any thick- Insulation: See: "Referenced Insulations ", any combination, any thick- ness. ness. Membrane: "Sure - Weld ". Membrane: "Sure -Weld FleeceBACK® 100 or 115" (TPO). 2. Deck: NC Incline: 1 -1/2 15. Deck: NC Incline: 1 -1/2 Insulation: Carlisle HP Recovery Board, 1/2 to 3 in.; Carlisle Recovery Insulation (Optional): Any UL Classified, any thickness. Board, 1/2 in. min, over any Classified insulation, any combination, any Insulation: 1/2 in. thick "HP Recovery Board ". thickness; cellular concrete, precast concrete with grouted joints or Membrane: "Sure -Weld FleeceBACK® 100 or 115" (TPO). structural (poured -in- place) concrete. 16. Deck: NC Incline: 3 Membrane: "Sure - Weld ". Insulation: Any UL Classified, any thickness. 3. Deck: NC Incline: 1 -1/2 Barrier Board: 1/4 in. G -P Gypsum DensDeck® or 1/2 in. gypsum Insulation: See "Referenced Insulations ", any combination, any thick- wallboard. ness. Membrane: "Sure -Weld FleeceBACK® 100 or 115" (TPO). Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". 17. Deck: C -15/32 Incline: See Note 4. Deck: NC Incline: 1 -1/2 Slip Sheet: Two layers Carlisle "FR Base Sheet ", Elk " VersaShield Insulation: Carlisle HP Recovery Board, 1/2 to 3 in.; Carlisle Recovery Underlayment" or " VersaShield FB -2S ". Board, 1/2 in. min, over any Classified insulation, any combination, any Insulation : Any UL Classified (except EPS ), any combination, any thickness; cellular concrete, precast concrete with grouted joints or thickness. structural (poured -in- place) concrete. Membrane: Any UL Classified Carlisle TPO membrane. . Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". Note: Max incline shall be in accordance with Classification estab- 5. Deck: NC Incline: 3 lished for the insulation /membrane roofing system, but can not Insulation (Optional): Any UL Classified, any combination, any thick- exceed 2:12. ness. 18. Deck: NC Incline: 1 Barrier Board: 1/2 in. thick gypsum wallboard or 1/4 in. thick G -P Insulation: Any UL Classified expanded or extruded polystyrene, any Gypsum DensDeck® combination, any thickness Membrane: "Sure Weld ". Slip Sheet: One layer Atlas Roofing "FR -10" or "FR -50 ", Carlisle "FR 6. Deck: C -15/32 Incline: See Note Base Sheet" or Elk "VersaShield Underlayment" or " VersaShield FB -2S" Slip Sheet: Two layers Carlisle "FR Base Sheet ", Elk " VersaShield Membrane: Any UL Classified Carlisle TPO membrane. Underlayment" or "VersaShield FB -2S ". . 19. Deck: C -15/32 Incline: See Note Insulation: Any UL Classified (except EPS), any combination, any Slip Sheet: Three layers Elk " VersaShield FB -IS ". thickness. . Insulation: Any UL Classified (except EPS), any combination, any Membrane: Any UL Classified Carlisle TPO membrane. thickness. Note: Max incline shall be in accordance with Classification estab- Membrane Any UL Classified Carlisle TPO membrane. • lished for the insulation /membrane roofing system, but can not Note: Max incline shall be in accordance with Classification estab- exceed 2:12. lished for the insulation /membrane roofing system, but cannot exceed 7. Deck: C -15/32 Incline: Unlimited 2:12. Insulation (Optional): Any UL Classified, any combination, any 20. Deck: C-15/32 Incline: See Note thickness. Slip Sheet: Three layers Elk "VersaShield FB -1S ". Barrier Board: 1/2 in. min gypsum board or 1/4 in. thick G-P Gypsum Insulation (Optional): Any UL Classified (except EPS and wood DensDeck® with staggered joints (6 in. offset). fiberboard), any combination, any thickness. Membrane: "Sure -Weld HS" or "Sure -Weld GSD ". Membrane: Any UL Classified Carlisle TPO membrane. 8. Deleted Note: Max incline shall be in accordance with Classification estab- 9. Deck: C -15/32 Incline: See Note lished for the insulation /membrane roofing system when insulation is Slip Sheet: One layer Atlas Roofing "FR -10" or "FR -50 ", Carlisle "FR used or established for the membrane roofing system applied over fiberboard or gypsum when insulation is not used. Base Sheet" or Elk "VersaShield Underlayment" or " VersaShield FB -2S ". Class B - Mechanically Fastened (T P 0) Insulation: Atlas Roofing "ACFoam III ", 1.5 in. thick with joints 1. Deck: C-15/32 Incline: See Note staggered min 6 in. from the deck joints. Base Sheet: One layer, mechanically fastened, of one the following: Membrane: Any UL Classified Carlisle membrane. Note: Max incline shall be in accordance with Classification established A.) Owens Corning "Perms Ply No. 28" . B.) GAF "Gafglas #75 Base Sheet" . for the insulation /membrane roofing system. C.) Johns Manville "Glasbase" . 10. Deck: C -15/32 Incline: 1/2 D.) Tamko "Glass Base" . Slip Sheet: Two plies Atlas Roofing "FR -50 ". E.) Celotex Type G2 "Vaporbar GB" . Membrane: Any UL Classified Carlisle membrane. F. Carlisle "FR Base Sheet ". 10A.Deck: C -15/32 Incline: See Note G Elk "VersaShield Underlayment" or "VersaShield FB -2S ". Slip Sheet: Two layers Carlisle "FR Base Sheet" or Elk " VersaShield Insulation: See "Referenced Insulations ", min 1 -1/2 in. thickness; Underlayment" or VersaShield FB -2S ". Carlisle HP Recovery Board or UL Classified wood fiber board, min 1 in. Membrane: Any UL Classified Carlisle TPO membrane. thick; Carlisle HP Recovery Board or UL Classified wood fiber board, Note: Max incline shall ire in accordance with Classification established min 1/2 in. thick over any Classified insulation (any combination), min for the membrane roofing system applied over fiberboard or gypsum, 1 in. thick. The bottom insulation layer joints are to be staggered a min 6 but can not exceed 1- 1/2:12. in. from the deck joints. 11. Deck: C -15/32 Incline: 2 -1/2 Membrane: Any UL Classified Carlisle membrane. Insulation (Optional): Any UL Classified, any combination, any Note: Max incline shall be in accordance with Classification estab- thickness. lished for the insulation /membrane roofing system but not to exceed Barrier Board: 1/2 in. min gypsum board. 1 in. Membrane: '72 mil Sure -Weld EXTRA" or "80 mil Sure-Weld EXTRA" 2. Deck: C -15/32 Incline: See Note 12. Deck: NC Incline: 1 -1/2 Insulation: Carlisle HP Recovery Board or UL Classified wood fiber Insulation: Carlisle HP Recovery Board, 1/2 in. to 3 in., Carlisle board, min 1 -1/2 in. thick. The bottom insulation layer joints are to be Recover Board, 1/2 in. min, over any Classification insulation, any staggered a min 6 in. from the deck joints. LOOK FOR THE UL MARK ON PRODUCT October 9, 2006 Norris & Stevens 621 SW Morrison, Suite 800 DEC 2 , ; 2nr3 Portland, OR 97205 CITY Ur Attention: Scott Perry BldtLD@ Reference: Tigard Central Industrial Park Buildings E & F Dear Scott: Per your request, we herein submit the following revised proposal for reroofing the above referenced buildings: Membrane Roofing Specification 1. Over metal roofing mechanically attach one layer of 1 -1/2" polyisocyanurate rigid insulation and one layer of 1 /4" DensDeck cover board. Note: Upon installation of new roof system we may encounter decking or conditions outside of our scope of work that will require repair. All repairs necessary will be made with owner approval at an additional charge of $60 per hour and materials at cost plus 15 %. The insulation will provide an additional R factor of 10 for increased heat Toss protection and prevent condensation. 2. Over insulation, in accordance to manufacturer specifications, furnish and install a Firestone TPO membrane roofing system. This system consists of a mechanically attached layer of .060 white TPO membrane. This system carries a Class A fire rating. 3. Install pressure treated 2 "x 6" lumber along gutter and rake edges. Furnish and install 24 gauge prepainted drip metal along external gutter edges and gravel stop metal along rake edges. 4. Install new sheet metal drops to connect to existing downspouts at built -in gutters. Reuse external gutters. 5. Furnish owner with a 2 -year Snyder Roofing of Oregon LLC guarantee and a 10 -year manufactures material warranty. Tigard Central Ind -Bldg E +F- 10 -9 -06