Loading...
Permit CITY OF TIGARD MASTER PERMIT III IS COMMUNITY DEVELOPMENT Permit #: MST2010 -00181 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 10/26/2010 Parcel: 1S133CA11100 Jurisdiction: TIGARD Site address: 10973 SW SAGE TER Subdivision: VILLAGE AT SUMMER CREEK Lot: 34 Project: Village at Summer Creek, Lot 34 Project Description: Building 9. New SFA. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 60 sf Basement: 0 sf Left: 3.5 Parking Spaces: 2 Height: 33 Bathrooms: 3 Second: 703 sf Garage: 620 sf Front: 12 Smoke Dwelling Units: 1 Third: 697 sf Right: 3.5 Detectors: Yes Total: sf Value: $169,855.22 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Catch Basins: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Other Fixtures: 0 Tubs /Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Bckflw Prevntr: 0 MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum <100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0 Ea add'I 500 sf: 3 20 1-400 amp: 0 201 -400 amp: 0 1st W/O Svc/Fdr: Limited Energy: 401 -600 amp: 0 401 -600 amp: 0 Ea add'I Br Cir: 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY SF Residential Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: Owner: Contractor: Required Items and Reports (Conditions) CENTEX HOMES CENTEX HOMES 1 MST Ersn Cntrl 503 - 681 -4444 16520 SW UPPER BOONES FERRY 16520 SW UPPER BOONES FERRY RD STE 200 RD, STE 200 PORTLAND, OR 97224 PORTLAND, OR 97224 PHONE: 503 - 608 -3060 PHONE: 503 - 608 -3060 FAX: Total Fees: $13,057.64 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. A • . •: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -00 -0010 through ■ • R 952- 001 -0100. You may obtain a copy of the rules or direct questions to OUNC b callin e 1 46.6699 or 1.800.332.2344. i Iss • d By: L G U / 4 _' Permittee Si. • � � d' 21,,, W! • _ . . Building Permit Applicati �� 7 3i'M (3.__ og., R es dent>aa (� I�,�JJ.' � , �� __vj _ _. ___r._.. FOR OFFICE USE ONLY City of Tigard S E P 6 3 2 010 Received ii 13125 SW Hall Blvd., Tigard, OR 97 223 Date/B _ i2 3 /8 71 Penult No.: H19T/��O 6G i �! g Plan Revie� /� Phone: 503.639.4171 Fax: 503.59 Date/B : ,� /�It � /'„ 0 Other Permit: 5W2- ?o/O -Go 139 Inspection Line: 503.639.4175 �� OF TIGARD Received Read lug TIGARD P Y °Y H SccPage2for Internet: www.tigard- or.gov BUILDING DIVISION Notified/Method: Supplemental Information RE UIREp A x-" :1-c- ` : '-' �` " ..4 _ - -_ , :.4. -' - E �©E YYO { --- _ _ ..._ .. ..__, :.� !z..., 7_::: A `2` III 9DWJ!7i II�Cs '. 1 ® New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the i work indicated on this application. ® 1- and 2- family dwelling ❑ Commercial /industrial Valuation: $169,855.22 ❑ Accessory building ❑ Multi- family Number of bedrooms: 3 ❑ Master builder ❑ Other: Number of bathrooms: 3 r JOB `S E'.?[NQ„ l� i)O %AD13 D iI"s,OCAtI'ON( Total number of floors: 3 Job site address: !09.73 5 1 e, New dwelling area: 1460 square feet City/State/ZIP: TIGARD OR, 97223 Garage/carport area: 620 square feet •b4 Suite/bldg. /apt. no.: I Project name: VILLAGE AT SUMMER CREEK Covered porch area: 33 square feet 7C3 Cross street/directions to job site: CORNER OF SW BARROWS RD, Deck area: 160 square feet SW 135 AVE, AND SW SCHOLLS FERRY RD Other structure area: ir)E30 j ' square feet - � .lr �SO" Subdivision: VLLAGE AT SUMMER CREEK Lot no.: St Permit fees* are based on the value of the work performed. — `` Indicate the value (rounded to the nearest dollar) of all Tax map/parcel no.: equipment, materials, labor, overhead, and the orofit for the DpS�@R'IPr71I01YY (01 }'}YO--Rk work indicated on this application. NEW SFR TOWNHOUSES Valuation: $ UNIT A 1460 SQ. FT. Existing building area: square feet New building area: square feet r tt1 iP.R© bRII'nY -- O iNiii1 i ',450474 ; Number of stories: Name: CENTEX HOMES Type of construction: Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Occupancy groups: City/State/ZIP: PORTLAND OR, 97224 Existing: Phone: (503)608 -3060 Fax: (503)608 -3061 New: IbI ASP PiCA> j#I ®' CUNII CT PDRSON J L — .__w •f _._ --_ -_ _:_ -._ ----_ _ _,,... Business name: CENTEX HOMES All contractors and subcontractors are required to be Contact name: GARY CULP licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 16520 SW UPPER BOONES FERRY RD, STE 200 jurisdiction in which work is being performed. If the City / State/ZIP: PORTLAND OR, 97224 applicant is exempt from licensing, the following reasons apply: Phone: (503) 608 -3060 Fax: : (503) 608 -3061 E -mail: gary.culp @pultegroup.com `; CONTRACTOR ' Business name: CENTEX HOMES -- - -- - . - `._BUII,DIN *:.. '' .' " - ". , .:' Address: 16520 SW UPPER BOONES FERRY RD, STE 200 (P /edse;r ejenro jdsclicrlulej City /State/ZIP: PORTLAND OR, 97224 Structural plan review fee (or deposit): FLS plan review fee (if applicable): Phone: (503) 608 -3060 Fax: (503) 608 -3061 CCB lie.: 182591 Total fees due upon application: Authorized signature: / \ Amount received: 4 .766.4Q A � / .....-.A...4 / This permit application expires if a permit is not obtained 9 within 180 clays after it has been accepted as complete. Print name: GARY CULP / Date: ! /� ` T// f x Fee methodology set by Tri- County Building Industry Service Board. 1:\Building\Permits \BUP -RES PermitApp.doc 10/01/09 440- 4613T(I I /02 /COM /WEB) • A Electrical Permit ApplaloCI 1 4 . . , .;, - --14. :k r:( - :"A4iT'4. '.--:'Snitatealliftaieistist7 • ''. - ,..4r ,:. - ;-. 7.1, WC71 City of Tigard SEP ?= 3 ZOICI Received pik. n ,.., Date/13y: : "P / (Z•h Permit No.: W/rpe,,ito —Celle/ re - -1- . .. . .,.. 13125 SW Hall Blvd.. Tigard, OR 97223 Plan Review Ap- , .-L. Phone: 503.639.4171 Fax: Date/By: Other Pernik: cthe-s 7— evieSf 0} W#M Inspection Line: 503.639.417 01TOMIGARD Date Ready/By: luris: El See Page 2 for tali ii i i i pl 61 Internet: www.ligard-or.go\BOLDING DIVISIO. Notificd/Method: Supplemental Information El New construction El Addition/alteration/replacement Please check all that apply (submit 2 sets of plans w/items checked below): 0 Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. gPtGOi;V:01F' e:ON:Stitif01ON. :'.. : 1:':-.,, ... - T::: ,- . ;:::; exceeds 10,000 amps at 150 volts or 0 Floating buildings. less to ground, or exceeds 14,000 0 Commercial-use agricultural 0 1- and 2-family dwelling 0 Commercial/industrial 0 Accessory building amps for all other installations. buildings. 0 Multi-family 0 Master builder 0 Other: CI Fire pump. 0 Installation of 75 KVA or 0 Emergency system. larger separately derived system. 4013: S1,7q::1NEOPLIN4:TIOpl'/AND:LOCATNISIL.. _ q , :, -7 . .,,,.,7, 0 Addition of new motor load of Job no.: Job site address: / 1, Me46 la< 100HP or more. 0 Six or more residential units. 0 occupancy. Recreational vehicle parks. City/State/ZIP: TIGARD OR 97223 0 Health-care facilities. 0 Supply voltage for more than 0 Hazardous locations. 600 volts nominal. Suite/bldg./apt. no.: Project name: VILLAGE AT SUMMER CREEK 0 Service or feeder 600 amps or more. ,. .t :f* Cross street/directions to job site: CORNER OF SW BARROWS RD, Description I OtY. I Fee. 1 Total I • New residential single- or multi-family dwelling unit. SW 135 AVE, AND SW SCHOLLS FERRY RD Includes attached garage. Subdivision: VILLAGE AT SUMMER CREEK Lot no.:0 1,000 sq. ft. or less 1 1 168.54 168.54 1 4 Ea. add'I 500 sq. R. or portion 3 1 33.92 161:3„, 1 i Tax map/parcel no.: Limited energy, residential 1 75.00 75.00 2 ;:::: 0*i1 ;-[;:VEk;;Zei-"-1''' (with above sq. ft.) Limited energy, multi-family NEW SFR TOWNHOUSES residential (with above sq. ft.) 75.00 2 Services or feeders installation, alteration, and/or relocation 200 amps or less 100.70 2 ErtROPERTY..DWNtiii s, i ., : , ,. , . ,.. : ' mi:TENAINT-; . ,-.., :, ,- - .2-.. 201 amps to 400 amps 133.56 2 401 amps 10 600 amps 200.34 2 Name: CENTEX HOMES 601 amps to 1,000 amps 301.04 2 Address: 16520 SW UPPER BOONES FERRY ROAD, STE 200 Over 1,000 amps or volts 552.26 2 City/State/ZIP: PORTLAND OR 97224 Temporary services or feeders installation, alteration, and/or relocation Phone: (503)608 Fax: (503 200 amps or Icss 59.36 I 201 amps to 400 amps 125.03 2 Owner installation: This installation is being made on property that I own which is not ; 401 amps to 599 amps 168.54 2 intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. Branch circuits - new, alteration, or extension, per panel Owner signature: Date: A. Fee for branch circuits with .,..... . ,..., above service or feeder lee , =i1.,:imi ‘0 7.42 2 each branch circuit Business name: CENTEX HOMES B. Fee for branch circuits without service or feeder fee, first 56.18 2 Contact name: GARY CULP branch circuit 1 Each addl branch circuit 7.42 2 Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Miscellaneous (service or feeder not included) Each manufactured or modular City/State/ZIP: PORTLAND OR, 97224 67 .8 4 2 dwelling, service and/or feeder Phone: (503) 608 Fax: : (503) 608 Reconnect only 67.84 2 Pump or irrigation circle 67.84 2 E-mail: gary.culp@pultegroup.com 1 . .,_ . ., Sign or outline lighting 67.84 2 Signal circuit(s) or limited-energy Business name: GARNER ELECTRIC panel, alteration, or extension. Page 2 2 Each additional inspection over allowable in any of the above Address: 2920 SE BROOKWOOD AVE, STE A Additional inspection (1 hr min) 66.25/ hr Investigation (I hr min) 66.25/ lir City/State/ZIP: 1IILLSBORO OR, 97123 Industrial plant (1 hr min) 78.18/ hr Phone: (503) 648 Fax: (503) 642 Inspections for which no fee is 90.00/ hr specifically listed (V: hr min) CCB Lic.: 182591 Electrical Lic.: 34-305C Suprv. Lic.: ., .: : : : E.L11,C:14104; PutiOry FEES Subtotal: Suprv. Electrician signature, require./ ,A Plan review (25% or permit fee): . • Print name: CHUCK GA , / ER / 1 ," State surcharge (12% olpennit fee): 4r( ,114,— / / Date: TOTA L PERMIT FEE: f :74 Authorized signature: / il i t / . , '---A Ay i t Tith permit application expires if a permit is not obtained within 180 – r *•,,--'----- 7 r 4/ days after m fter it has been accepted as coplete. Print name: Date. . li.j j . Number of inspections allowed per perntit 1 d 07/01/10 440-4615T( 11/05/CO NIAVEB i .. . . : .- ' „ .. , . . , Mechanical Permit Applicati '----, ' ''' ' ' NM; IN 2 3 zolo R g a. 9 h (0", 13125 SW Hall Blvd., Tigard, OR 97223 sEp Permit No.: Plan Review Phone: 503.639.4171 Fax: 501598196° • . CI I - Y Tr RD OF ' ....... ,.._ Date/BY: Other Perniit: atA/i2 p.oto-eu2/ 357 TIGARD Inspection Line: 503.639.4175 ak D te Ready/By: Juris: 21 See Page 2 for . Internet: WWW . tigard BUILDING DiVISial Notified/Method: Supplemental Information New construction 0 Addition/alteration/replacement Mechanical permit fees* are based on the value of the work CZ performed. Indicate the value (rounded to the nearest dollar) of all 0 Demolition 0 Other: mechanical materials, equipment, labor, overhead, and profit. _ _. '_. ......._ , .,....... _ ,. Value $ 7 5:: • __________________ .., ,„.....„_,,_,._,,,...,,,,t.:.•=_ ,..,-_-_,,...__,,,-,t ,,t,-_ := -,--2_,,,,,-___ , : --___ 2 `1. - 7. - li ti-wia i y , tri tz r : :., :,_: :. __- • zn A .2_''`‘ ...^.22 , 4..a.,... -. 5 ,....;, _-__, El I- and 2-family dwelling 0 Commercial/industrial 0 Accessory building _, For special information use checklist. 0 Multi 0 Master builder 0 Other: Description 1 QtY. 1 Ea. 1 Total p,:i. : :;(14i$:17:71001nOWATIVN!". A/!.4)7.4:04 .f,.::: - .1.,'-:.,Li -, ; Heating/cooling Air conditioning Job site address: /073 34) 0,68 7 (requires site plan showing placement) 46.75 City/State/ZIP: TIGARD OR, 97223 Fumace 100,000 BTU (ducts/vents) 1 46.75 46.75 Furnace 100,000+ BTU (ducts/vents) 54.91 Suite/bldg./apt. no.: Project name: VILLAGE AT SUMMER CREEK Heat pump 61.06 Cross street/directions to job site: CORNER OF SW BARROWS RD, Duct work 23.32 Hydronic hot water system SW I 35TH AVE, AND SW SCHOLLS FERRY RD Residential boiler (radiator or 23.32 hydronic) 23.32 Unit heaters (fuel-type, not electric), in-wall, in-duct, suspended, etc. 46.75 Subdivision: VILLAGE AT SUMMER CREEK Lot no.: 14 Flue/vent for any of above 23.32 . Other: 23.32 Tax map/parcel no.: Other fuel appliances 7.:T_T" : .::•: : ; =-.,:,:,off : Water heater 1 2332 23.32 '-'--------'- '.-- '''.- - -.'"------- --'-' - --- - --- -----.- Gas fireplace 33.39 NEW SFR TOWNHOUSES Flue vent for water heater or gas UNIT A 1460 SQ. FT fireplace 23.32 . Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 « Chimney/liner/flue/vent 23.32 L'...:..::::: :-:_::..: ___,....: • _:. -..:..-4,..-,..“.....:_, ..:..4.:..'-1.,,,....._:;1.,,.:,.....,..:.,:4,:_-:-...-:=..--- Other: _ 23.32 Name: CENTEX HOMES Environmental exhaust and ventilation Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Range hood/other kitchen 1 33.39 33.39 equipment City/State/ZIP: PORTLAND OR, 97224 Clothes dryer exhaust 1 33.39 33.39 Single-duct exhaust (bathrooms, Phone: (503)608-3060 Fax: (503)608-3061 toilet compartments, utility rooms) 4 23.32 93.28 4-4***11:: :i.. -..-::.,! i : _,...:-. _ - ,141 , _ : i' , ;:;:l Attic/crawlspace fans 23.32 Other: 23.32 Business name: CENTEX HOMES Fuel piping Contact name: GARY CULP $14.15 for first four; $4.03 for each additional Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Furnace, etc. 1 14.15 Gas heat pump City/State/ZIP: PORTLAND OR, 97224 Wall/suspended/unit heater Phone: (503) 608-3060 Fax: : (503) 608-3061 Water heater 1 Fireplace E-mail: gary.euIp@pultegroup.com Range I 67 , : -,.: :- 7, ::. ':.=" :_::: ::: .:''':1 Barbecue Business name: MUEHE QUALITY HEATING INC. Clothes dryer (gas) Other: Address: 7301 SW KABLE LANE, STE 500 ;:. .:,.:-. . • _ iymeHANWAUPERMITTEES* City/State/ZIP: PORTLAND OR, 97224 Subtotal 2,44-.2e Minimum permit fee ($90.00) Phone: (503) 598-0966 Fax: (503) 598-8498 Plan review (25% of permit fee) CCB lic.: 50096 State surcharge (12% of permit fee) 2, 1 1 TOTAL PERMIT FEE 27Sr i This permit application expires if a permit is not obtained within 180 Authorized signature: 1 1 days after it has been accepted as coplete. Print name: KYLE BIRMA '. Dale: ',A.7io * Fee methodology m odology set by Tri-County Building industry Service Board i: \ Building \ Permits \ MEC-Pcrm it App doc 10/01/09 40.46 IT (11/02/COM/WEB) Plum bin • Permit A 1 1 li _,a. .• M t Building Fixtures p ' , VEO FOR OFFICE USE ONLY City of Tigard � Received Isil g c 'p ° 209 Date/By: 9A /O ; PernitNo.: /��l/ �,0 /O ._ f ' 13125 SW Hall Blvd., Tigard, OR 122 ( Phone: 503.639.4171 Fax: 503.598.1960 f� Plan Review TIGARD Inspection Line: 503.639.41750Y OF I Y I171A ® Date/By: Other Permit No.: O . /�-6 45y Internet: www.tigard - or.gov BUILDING DIVISION Date Ready /By: luris• !�I See Page 2 for D IIVl77 Notified/Metbod: Supplemental Information ' 'T1/PE .OP WORK . , . ® New construction ❑ Demolition FEE *• SCHEDULE ' ❑ Addition/alteration/replacement ❑ Other: For special information use checklist. Description 1 Qty. 1 Ea. 1 Total CATEGORY OF CONSTRUCTION New 1 - 2- family dwellings (includes 100 ft. for each utility connection) ® I- and 2- family dwelling ❑ Commercial /industrial SFR (1) bath 312.70 SFR (2) bath 437.78 ❑ Accessory building ❑ Multi- family SFR (3) bath 1 500.32 500.32 ❑ Master builder ❑ Other: Each additional bath kitchen 25.02 ' ' JOB SITE INFORMATION' AND' LOCATION • Fire sprinkler ( sq. ft.) Page 2 Job site address: 10,-2 649 .5466 l t Site utilities: Catch basin or area drain 18.76 City /State /ZIP: TIGARD OR, 97223 Drywell, leach line, or trench drain 18.76 Suite/bldg. /apt. no.: Project name: VILLAGE AT SUMMER CREEK Footing drain (no. linear ft.: 100) 1 Page 2 Cross street/directions to job site: CORNER OF SW BARROWS RD, Manufactured home utilities 50.03 SW 135 111 AVE, AND SW SCHOLLS FERRY RD Manholes 18.76 Rain drain connector 1 18.76 Sanitary sewer (no. linear ft.: 100) 1 Page 2 Storm sewer (no. linear ft.: 100) 1 Page 2 Subdivision: VILLAGE AT SUMMER CREEK Lot no.:M Water service (no. linear ft.: 100) 1 Page 2 Tax map /parcel no.: Fixture or item: DESCRIPTION OF WORK • Backtlow preventer 31.27 . Backwater valve 12.51 NEW SFR TOWNHOUSES Clothes washer 1 25.02 UNIT A 1460 SQ. FT. Dishwasher 1 25.02 Drinking fountain 25.02 ® OWNER ❑ TENANT - . , Ejectors /sump 25.02 Name: CENTEX HOMES Expansion tank 12.51 Fixture/sewer cap 25.02 Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Floor drain/floor sink /hub 25.02 City /State/ZIP: PORTLAND OR, 97224 Garbage disposal 1 25.02 Hose bib 2 25.02 ❑ APPLICANT • 1M CONTACT PERSON lee maker 1 12.51 Business name: CENTEX HOMES Interceptor /grease trap 25.02 Medical gas (value: $ ) Page 2 Contact name: GARY CULP Primer 12.51 Address: 16520 SW UPPER BOONES FERRY RD, STE 200 Roof drain (commercial) 12.51 City /State /ZIP: PORTLAND OR, 97224 Sink/basin/lavatory 6 25,02 Fax: : (503) 608 -3061 Solar units (potable water) 62.54 E -mail: gary.culp @pultegroup.com Tub / shower /shower pan 2 12.51 Urinal 25.02 CONTRACTOR • Water closet 3 25.02 Business name: CRAFTWORK PLUMBING INC. Water heater 1 37.52 Address: 7737 SW CIRRUS DR Water piping/DWV 56.29 City/State/Zit': BEAVERTON OR, 97008 Other: 25.02 Subtotal r a Minimum permit fee: 572.50 CCB Lic.: 79666 Plumbin; Lic. no.: 20 -148PB Plan review (25% of permit tee) Authorized signature: � State surcharge (12% of permit tee) f • 'IOTA I. PERMIT FEE 6:6 . Print name: PETER POLLARD Date: K- 17°0 1:\ Building \Permits1PLMU- PcrmitApp.doc 10/01/09 440- 7616T(10 /02/COM/\VEB) Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I, 1 U e.��p , am the general contractor or the owner- builder at the following address: 20C113 ' 10C•1 Site Address: 1096( - tO4gR gre Tggeopc e,� City: 4064-2 - -_. h�I 2.0 Lo - Permit #: voi•ro■ . coo i WZ. 0#11M. 00(% Subdivision/Lot #: d CRceZe and /or Map and Tax Lot #: 7 ■� .3° To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and OAR 918- 480 -0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section 8318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture- sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: W Date: (a- Ge al Contractor or Owner - Builder l:\HuildingWorni\Rf S- MoistureSensiuvcWood.doc 09/25/08 Oregon Residential Specialty Code N1107.2 HIGH - EFFICIENCY INTERIOR LIGHTING SYSTEMS MSS"20Io 0o'z► oo — i Permit No.: 00 v3 v oo 1g Jurisdic "�' Site Address: c 't 3 -tog V togs. t - I0959 Subdivision/Lot #: and /or Map and Tax Lot #: 34 ..... 3 I By my signature below, I certify that a minimum of fifty (50) percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code NI 107.2) Signature: L' Date: 6 " Owner/ eral Contractor /Authorized Agent Print Name: 6 �ii✓�u ' ORSC Section N1107.2. High - efficiency interior lighting systems. A minimum of fifty (50) percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. Screw -in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent, or a minimum efficacy of 40 lumens per input watt. I:\BuildingWormAtliS-HighlMiciencyLighting.doc 07/01/08 S TREE T TREE CERTIFICATION I, 131 l ( 46 , owner/ agent for 'RA \. 4-to . (PLLASF. PRIN1 ) IPI Rt1TT iIOLDLRj do here certz that the following location meets City of Tigard land use and development standards for street tree installation and is consistent with the approved site plan. ii45 -r 2,0 t PERMIT NO.: 0 Y — 60e2c '7' kr / —log SITE ADDRESS: '/ y – /o g�� br S(1 S'�, f L, S(JBDIL'ISIO� �u��,� CZe R LOT #: 3t/ -3 ;Z .S'IGy /1TURF: , l/ DATE- ( $ -f, \1.R/ -1(d.\ T/ REC.EI I TD . l 'ERII7ID BY: 1)f1TI: ((f or- RI)) Tree lo( al /oil tien//ed per app no red she plan. - . -,,,..„...„ PERMIT NO. --s, CleanWater ' Services Our commitment is ci,tar. LOT !, , EROSION CONTROL INSPECTI•N REPORT DATE - . INSPECTOR SUBDIVISION OWNER/PERMITEE SITE ADDRESS ....„. .. , „...... ......, .....„ ,,,.„. .:. .... .. „ ..., ,... . -,.. , . . . . „... ..., ., .. ..... ...„,.. ,. ..... ..., .. .,,,,,, ., .. ..... ,„. . ...... - - . . ...,., ., , .. . , ... ... ...... ......„ . . .. .....,. .,.. A ,i,i.:;.,,..,,i:i.,!:::,:ili!,,,!,, .,i-,..,,:',:,.,,:.:::;-::.,,-..„:..:,,,,i s,;'' ,,!:::!!!!;,,,'•,!..,,:'...,.,,:::-.:,::,...',-,:.,::-.,,.3 oNTE ,.. ,.,. ......,., ,,,„„ ..,....„, ,,„....,, ,..,.. ,,.. ...,.,., „,... „.„...,.. _.,. , ...,........, .,..,. ,.., , , , ,, FIN AL INspE TioN THIS SITE MEETS THE POST-CONSTRUCTION EROSION CONTROL REQUIREMENTS SET FORTH IN CLEAN WATER SERVICES RESOLUTION AND ORDER NOTE: IF POST-CONSTRUCTION EROSION CONTROL MEASURES ARE STILL B EMPLOYED ON THIS SITE TO MEET CRITERIA FOR AN APPROVED FINAL il"NSPI:CTION, THE MEASURE(S) MUST RENIXIN IN PLACE UNTIL LANDSCAPING IS COMPLETT- OR PERMANENT GROUND COVER IS ESTABLISHED, A COPY OF THE FINAL EROSION CONTROL INSPECTION REPORT MUST BE FORWARDED TO THE NEW OWNER, AT WHICH TIME NEW OWNER ASSUMES THE RESPONSIBILITY FOR MAINTENANCE, REPAIR AND REMOVAL. • OTHER T YOU FOB YOUR COOPERAHON 7 TNsPEcTc . PHONE __ _ V illage at _X , _ ,Y „_ , V __X • Y f wrILT4 ummer Creek 15.3' 15.1 ' I 15.0' I 15.0' I 15 2' I RECEIVED I I I I I 1 1 23,1' 23.1' 23.0' 23.0 I i0 © 0 CITY OF TIGARD I I I I I l©. I p- BUILDING DIVISION I I ' ' ' ik 3.5' �-- [.._ 3.5' 1 I I I I I Building Plan: 9 34 35 36 37 Lots 34, 35, 36 & 37 I FF /TOW 193.50 1 FF /TOW 194.50 FF /TOW 194.50 FF /TOW 194.50 Units A -B -C -A I GS 192.80 I GS 193.30 GS 193.80 � GS 193.80 TOP 192.96 1 TOP 193.96 TOP 193.96 1 TOP 193.96 SITE PLAN I I I Scale: 1"-10' ti 0 X 2%9 I I I I ....... I _ I \ I I �_ , L L •..I _ .�._ 3.5 , - -- I • , I — — ti . .. I r 3 5 ,,,,,, IN, rat 2..I., I 1 • :. -. • ® r Q - �' 18.2' • - 2 L . -.: - .. © 2.1•.2 e 19 2 2 ;t� 1 9.2, 21;x • ®O cn .: } :1`•,- ui:�±: yr V `'e: . - Lti .1 r: -` =� V ! ,_•C -' ;: ?1.. :..v -:r -:.; �r. }ij::C: r.:.'•+�. Xx. .A/.. .rePir:M...'.. 4 J :� ?��r ='' "x •.:`dt.. .' u. ",-f L'' _ •. •' �a "�. 'mil'. ' -, • xt+•ty/rrsr: ': :ttd :':71..:;c ::rat'•, ,:A .., f.a5lr: r.':ririlA:M }:vd:r .... i . 4.i.« � ...:.......:...::: 1 II :.....:.,: :'le rr:. ;1,: .:. r:'i:rri r l } i::. , :.:: ? : ?:�i',:r' :'. Q Q III •.. `: .:...... ...... ::` ) rl : . :; l.? r:•:'• � . ''''•'' . °'': ::}• '''.J }: 5' + :: . . . ... . ... .. .... . ............. .. .... ... ..... . ....... .; S W SAGE TERRACE s s s ; ENGINE AS SOCIATES CORPORATION " 17757 Kelok Road Lake Oswego, OR 97034 Tel_ (503) 636 -4005 Fax (503) 636 -4015 r . iiiirb- CITY OF TIGARD - SITE PLAN REVIEW BUILDING PERMIT NO.: l'{Gj I o /0 OtO 18C ,!, PLANNING DIVISION: s ?e i=;nal Sift. Play/ y /3/ Required Setbacks: fp Approved ❑ Not Approved Side Street Side: J k� � ooto -iovo I . PPR 2voto - 0,90 Front. Garage: Rear: t Visual Clearance:N /A ❑ Approved ❑ Not Approved i . Building Height- feet 1 ' `A S Service Provider Letter Required: ❑ Yes K,I No .' ❑ Rece ed s) • (4 4ij . 0 - ext . Date: f o —0 —(0 ENGINEERIN DEPA TM ENT: Actual Slope °/ „ Approved ❑ Not Approve(/ 1. Site lilt : (- AApproved 9ed Date: D 6 l Notes: CITY Of TIGARD - SITE PLAN REVIEW BUILDING PERMIT NO: , • Street Trees: Approved 0 Meg Apiploaed Pro Appebved Q" ed f BY 'O 11.0. D e: / d/ 8 0/0 Notes: j j • [iA - T— t ,9d0-60 /t /t f - 3 RECEIVED Structural Calculations 5E 4� SEP 2 [010 for CITY OF TIGARD BUILDING DIVISION Full Lateral & Gravity Analysis of Plan A 1460 Lot 34, Summer Creek Townhomes Tigard, OR Prepared for Pulte Group September 21, 2010 JOB NUMBER: CEN -090 ** *Limitations * ** Engineer was retained in limited capacity for this project. Design is based upon information provided by the client, who is solely responsible for the accuracy of same. No responsibility and /or liability is assumed by, or is to be assigned to the engineer for items beyond that shown on these sheets. 117 sheets total including this cover sheet. P S ZRUCTUR 44 1,07 -C-01St S PRO City of Tigard t( ��` 01 S/� ; p • roved Plans I - �, 12,320 , ; i Date IcMGS Ms - c© Co tez cl • vu - GoI3 `A ` coy, � 4S . OFFICE COPY ® E J. Et� (^/ T 2 (0 ` � CO !84- 'EXPIRES* 12 -31 -2011 I This Paa of C is Null and Void if Signature above is not Original • Harper • Houf Peterson Righellis Inc. cuoivccns • - - l A P I D 3 C A P l ARL H I I : C . 7• f , U k L 205 SE Spokane St. Suite 200 • Portland, OR 97202 • [P] 503.221.1131 • [F] 503.221.1171 1104 Main St. Suite 100 • Vancouver, WA 98660 • [P] 360.450.1 141 • [F] 360.750.1 141 1133 NW Wall St. Suite 201 • Bend, OR 97701 • [P] 541.318.1161 • [F] 541.318.1 141 • • Structural Calculations RECEIVED SEP 2 4 2010 for CITY OF TIGARD Full Lateral & Gravity Analysis o fBDILDINGDIVISION Plan B 1332 Lot 35, Summer Creek Townhomes Tigard, OR Prepared for Pulte Group September 21, 2010 JOB NUMBER: CEN -090 ** *Limitations * ** Engineer was retained in limited capacity for this project. Design is based upon information provided by the client, who is solely responsible for the accuracy of same. No responsibility and /or liability is assumed by, or is to be assigned to the engineer for items beyond that shown on these sheets. 96 sheets total including this cover sheet. ss Ruc TuR ` k 12,320 J • OREGON } ' 15.� 9$ ,s1/44` Q' f EXPIRESI 12 -31 -2011 1 This Packet of Calculations is Null and Void if Signature above is not Original Harper • Houf Peterson Righellis Inc. l Atl , V3GAYE ARCH Ii EC • UVI IVN} 205 SE Spokane St. Suite 200 ♦ Portland, OR 97202 • [P] 503.221.1131 ♦ [F] 503.221.1171 1104 Main St. Suite 100 • Vancouver, WA 98660 ♦ [P] 360.450.1 141 ♦ [F] 360.750.1 141 1 133 NW Wall St. Suite 201 ♦ Bend, OR 97701 • [P] 541.318.1161 ♦ [F] 541.318.1 141 Structural Calculations RECEIVEE for SEP2,42130 CITY OF T1GARL Full Lateral & Gravity Analysis of BUILDINGDIVISIC N Plan C 1 186 Lot 36, Summer Creek Townhomes Tigard, OR Prepared for Pulte Group September 21, 2010 JOB NUMBER: CEN -090 ** *Limitations * ** Engineer was retained in limited capacity for this project. Design is based upon information provided by the client, who is solely responsible for the accuracy of same. No responsibility and /or liability is assumed by, or is to be assigned to the engineer for items beyond that shown on these sheets. 98 sheets total including this cover sheet. OS\ „ NROF �i k � �12,32 0 R . r J &4,tz%- tI OREGON Y15,�`��� J E !EXPIRES' 12 -31 -2011 1 This Packet of Calculations is Null and Void if Signature above is not Original Harper '• Houf Peterson Righellis Inc. t A ND$GAFL ` AHGiII ?EC' 3 4U :L V: NO 205 SE Spokane St. Suite 200 o Portland, OR 97202 0 [P] 503.221.1131 0 [F] 503.221.1171 1104 Main St. Suite 100 o Vancouver, WA 98660 . [P] 360.450.1 141 0 [F] 360.750.1141 1133 NW Wall St. Suite 201 • Bend, OR 97701 • [P] 541.318.1161 • [F] 541.318.1 141 / Structural CaIcuIation for S E P 2 4 21"1 Full Lateral & Gravity Analysis •, ' I'IYOFTIGARD ILDING DIVISION Plan A 1460 Lot 37, Summer Creek Townhomes Tigard, OR Prepared for Pulte Group September 21, 2010 JOB NUMBER: CEN -090 ** *Limitations * ** Engineer was retained in limited capacity for this project. Design is based upon information provided by the client, who is solely responsible for the accuracy of same. No responsibility and /or liability is assumed by, or is to be assigned to the engineer for items beyond that shown on these sheets. 117 sheets total including this cover sheet. s/ Ruc T uRA op , PROF E R � �� 12,320 .41e.' 4.- d t...=. t OREGON = - Y 15, AO 4- J E 'EXPIRES 12 -31 -2011 1 This Packet of Calculations is Null and Void if Signature above is not Original O t Harper Houf Peterson Righellis Inc. nn.n¢EHI. ,e. eas IANUYCA,'E AnGr.TEC Vl YCF9 205 SE Spokane St. Suite 200 ♦ Portland, OR 97202 • [P] 503.221.1131 ♦ [F] 503.221.1171 1 104 Main St. Suite 100 • Vancouver, WA 98660 ♦ [P] 360.450.1 141 ♦ [F] 360.750.1 141 1133 NW Wall St. Suite 201 ♦ Bend, OR 97701 • [P] 541.318.1 161 ♦ [F] 541.318.1 141