Loading...
Report Organization name /phone Representative name /Phone Installer CAPITOL ELECTRIC CO., INC. DAN WILSON, (503) 255 -9488 i - Supplier CAPITOL ELECTRIC CO., INC. DAN WILSON, (503) 255 -9489 Service organization Location of record (as- built) drawings: Location of owners manuals: Location of test reports: A contract, dated , for test and inspection in accordance with NFPA standard(s) No(s). , dated , is in effect. 2. Record of System Installation (Fill out after installations complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by on , included the devices shown below, and has been in service since X NFPA 72, Chapters 1 2 3 4 5 6 7 (underline all that apply) X NFPA 70, National Electrical Code, Article 760 X Manufacturer's instructions Other (specify): Signed: Dan Wilson Date: 11/27/01 Organization: CAPITOL ELECTRIC COMPANY, INC. 3. Record of System Operation All operational features and functions of this system were tested by on and found to be operating properly in accordance with the requirements of: X NFPA 72, Chapters 1 2 3 4 5 6 7 (underline all that apply) X NFPA 70, National Electrical Code, Article 760 X Manufacturer's instructions Other (specify): Signed: Dan Wilson Date: 11/27/01 Organization: CAPITOL ELECTRIC COMPANY, INC. 4. Alarm- Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 3 -5) Quantity: 9 Style: A Class: B MANUAL (a) 6 Manual stations 6 Noncoded, activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations. AUTOMATIC Coverage: Complete: Partial: (a) 1 Smoke detectors 1 Ion Photo (b) 4 Duct detectors 4 Ion Photo (c) Heat detectors FT RR FT /RR RC (d) Sprinkler waterflow switches: Transmitters Noncoded, activating Coded (e) 1 Other (list): building water flow alarm initiation from Honeywell sprinkler panel �5. Supervisory Signal- Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR •' (a) Coded stations (b) • Noncoded stations, activating transmitters (c) Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) Control Valve Supervisory Switches (b) Air Pressure Monitoring Supervisory Switch (c) Building temperature points (d) Site water temperature points (e) Site water supply level points Electric fire pump: (f) Fire pump power (g) fire pump running (h) Phase reversal Engine - driven fire pump: (i) Selector in auto position (j) Engine or control panel trouble (k) Fire pump running Engine- driven generator: (1) Selector in auto position (m) Control panel trouble (n) Transfer switches (o) Engine running ELEVATOR CONTROLS (p) Elevator Shunt Trip Power Monitor SMOKE DETECTION (q) Duct Smoke Detectors 6. Alarm Notification Appliances and Circuits Quantity and class (see NFPA 72, Table 3 -7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 40 Style Y Class: B (a) 26 Horn / Strobes (b) 12 Strobes (c) Horns (d) Chimes (e) Bells Inch (g) 1 Local annunciator (h) 1 Remote Annunciator 7. Signaling Line Circuits Quantity and class (see NFPA 72, Table 3 -6) of signaling line circuits connected to system: Quantity: Style: Class: :8. System Power Supplies (a) Primary (main): 1 Nominal voltage: 120 VAC Current rating: Overcurrent protection: Type: Circuit Breaker Current rating: 20 Amp Location: (b) Secondary (standby): X Storage battery: Amp -hour rating: 12.0 AH X Calculated capacity to drive system, in hours: 9.127 AH 24 60 Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating system software revision level(s): (b) Application software revision level(s): SKSS V1.02 (c) Revision completed by: Silent Knight (name) (firm) 10. Comments: (signed) for central station or alarm service company or installation contractor /supplier (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: (signed) for central station or alarm service company or installation contractor /supplier (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) Address: 15705 SW 72ND AVE., TIGARD, OR Fire Alarm Control Panel Mfg. & Model : SILENT KNIGHT 5208 10 ZONE FIRE ALARM CONTROL PANEL FIRE ALARM TROUBLE & MAINTENANCE LOG DATE DESCRIPTION OF PROBLEM OR SERVICE CORRECTIVE ACTION TECHNICIAN • . • _ FACP BATTERY CALCULATIONS CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office, (503) 257 -7121 Fax JOB NAME: NIKE / BRIDGESTONE GOLF JOB NUMBER: 21 -1153, 21 -1158 DATE: 11/26/01 PANEL DESCRIPTION: Silent Knight 5208 FACP BY: DWW DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE DESCRIPTION QUANTITY CURRENT CURRENT CURRENT CURRENT FACP INTERNAL COMPONENTS _ 0.00000 0.000 Silent Knight Model 5208 FACP 1 0.140 0.14000 0.460 0.460 Silent Knight Model 5235 Remote Annunciator 1 0.030 0.03000 0.050 0.050 0.00000 0.000 0.00000 0.000 0.00000 0.000 INITIATING DEVICES . SPRINKLER WATER FLOW 1 0.00000 0.100 0.100 SMK DET FCI SBS -1101 (Alarm) 1 0.00000 0.100 0.100 SMK DET FCI SBS -1101 (Supv) 1 0.0001 0.00010 0.000 Manual Pull Station 1 0.00000 0.100 0.100 DUCT SMK DET Syst Sensor DH400ACDC 4 0.02500 0.10000 0.100 0.400 SMK DETs FIRE SCREEN (Alarm) 1 0.100 0.100 SMK DETs FIRE SCREEN (Supv) 2 0.00012 0.00024 WHS HEAT DETS, MANUAL STATIONS 1 0.100 0.100 NOTIFICATION APPLIANCES . Wheelock DSM- 12124 -R Synch Module 2 0.038 0.076 Wheelock AS- 24MCW -FR (110cd) 1 0.218 0.218 _ Wheelock AS- 24MCW -FR (75cd) 5 0.165 0.825 Wheelock AS- 24MCW -FR (30cd) 3 0.110 0.330 Wheelock AS- 24MCW -FR (15cd) 11 0.072 0.792 Wheelock RSS- 24MCW -FR (110cd) 0.180 0.000 Wheelock RSS - 24MCW -FR (75cd) 0.137 0.000 Wheelock RSS - 24MCW -FR (30cd) 2 0.085 0.170 Wheelock RSS - 24MCW -FR (15cd) 10 0.049 0.490 FCI SNAC NOTIFICATION PWR SUPPLY 1 0.060 0.06000 0.120 0.120 0.000 0.000 AUXILLIARY DEVICES . "'-' � ' 0.00000 0.000 0.00000 0.000 STANDBY TOTAL CURRENT: I 0.33034 I STANDBY HOURS: 24 STANDBY AMP HOURS: 7.92816 TOTAL NAC CURRENT I 3.021 ALARM TOTAL CURRENT: I 4.431 ALARM MINUTES: 5 ALARM AMP HOURS: 0.3693 TOTAL CALCULATED AMP HOURS 8.297 APPLIED SAFETY FACTOR 1.10 • MINIMUM AMP HOURS REQUIRED 9.127 SELECTED BATTERY SIZE 12 EACH 12 VOLT, 12 AMP HOUR BATTERIES Bridgestone Batt Calc SK 5208.xls NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office (503) 257 -7121 Fax Job Name: NIKE / BRIDGESTONE GOLF Job Address: 15675 / 15705 SW 72nd AVE TIGARD Job Number: Prepared By: Dan Wilson Date: 11/26/01 Panel Description: SILENT KNIGHT 5208 FACP Panel No.: NAC 1.0 ALARM OUTPUT TOTALS OUTPUT 1 1.074. AMPS OUTPUT 2 0.914 AMPS OUTPUT 3 0.913 AMPS OUTPUT 4 0.120 AMPS TOTAL 1 3.0211 AMPS WIRE LENGTH TOTALS OUTPUT # 1 WIRE LENGTH 1 GAUGE OUTPUT 1 366 14 OUTPUT 2 351 14 OUTPUT 3 492 14 OUTPUT 4 6 14 TOTAL 1 12151 FEET Bridgestone EOLv Calc NAC.xls JOB INF SHEET NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office (503) 257 -7121 Fax Job Name: NIKE / BRIDGESTONE GOLF Job Address: 15675 / 15705 SW 72nd AVE TIGARD Job Number: Conductor Wire Guage ( 14 I Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C (167 Deg F) 3.07 Date: 11/27/01 Cable Length In Feet (source to end of line) 366 Total Circuit Current 1 1.074 Nominal System Voltage 24 Panel Description: SILENT KNIGHT 5208 FACP Minimum Device Voltage 20.4 Panel No.: NAC 1.0 Output No.: 1 Point To Point Method EOLv I 22.69 I Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock End Of Line Method EOLv I 21.59 I Circuit Within Limits ? YES Load Centering Method EOLv I 22.79 I Circuit Within Limits ? YES Dev _ Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) 1 FACP CLOSET DSM- 12/24 -R (1 CKT ONLY) NA 0.019 5 23.97 2 Bridgestone Tenant RSS - 24MCW -FW (30) STB WHT 30 Cd 0.085 45 23.68 3 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 26 23.52 4 Bridgestone Tenant AS- 24MCW -FW (110) H/S WHT 110 Cd 0.218 41 23.29 5 Bridgestone Tenant AS- 24MCW -FW (75) H/S WHT 75 Cd 0.165 48 23.08 6 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 45 22.93 7 Bridgestone Tenant RSS - 24MCW -FW (30) STB WHT 30 Cd 0.085 35 22.83 8 Bridgestone Tenant AS- 24MCW -FW (75) H/S WHT 75 Cd 0.165 29 22.77 9 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 25 22.73 10 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 38 22.70 11 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 29 22.69 12 22.69 13 22.69 14 22.69 15 22.69 16 22.69 17 22.69 18 22.69 19 22.69 20 22.69 Bridgestone EOLv Calc NAC.xls OUTPUT 1 NAC EOL VOLTAGE CALCULATION ;CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office (503) 257 -7121 Fax Job Name: NIKE / BRIDGESTONE GOLF Job Address: 15675 / 15705 SW 72nd AVE TIGARD Job Number: • • Conductor Wire Guage 14 Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C (167 Deg F) I 3.07 Date: 11/27/01 Cable Length In Feet (source to end of line) 351 Total Circuit Current 0.914 Nominal System Voltage! 24 I Panel Description: SILENT KNIGHT 5208 FACP Minimum Device Voltage 20.4 Panel No.: NAC 1.0 Output No.: 2 Point To Point Method EOLv I 23.01 I Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock End Of Line Method EOLv I 22.03 1 Circuit Within Limits ? YES Load Centering Method EOLv I 23.02 I Circuit Within Limits ? YES Dev _ Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) a-t':', -� j: "..S`��3 I Y x 2 t'^ w 6 X a+ - $. ,.� + y:�•t . a} + F a,. �,' -r St n.� 4 1 '"' �cr�F„' "• � w #�� s,«.,�� '��; #.'.?�'ti���r��. ". ����ci� +.,& -n >`�' � +., *a4.v, ` t�..a �fi �A`.4!t"�f.t �k ?' #<.,.G Ne... a.�a �c � r:a:�,SR.r.vt f��n, ° iwt?r��.,�4�.�3t+' ;�`p 1 FACP CLOSET DSM- 12/24 -R (1 CK OONLY) NA 0.019 5 23.97 2 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 23 23.85 3 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 23 23.73 4 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 28 23.59 5 Bridgestone Tenant RSS- 24MCW -FW (15) STB WHT 15 Cd 0.049 22 23.49 6 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 5 23.47 7 Bridgestone Tenant AS- 24MCW -FW (30) H/S WHT 30 Cd 0.110 28 23.36 8 Bridgestone Tenant AS- 24MCW -FW (75) H/S WHT 75 Cd 0.165 45 23.22 9 Bridgestone Tenant AS- 24MCW -FW (30) H/S WHT 30 Cd 0.110 39 23.14 10 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 40 23.08 11 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd • 0.072 28 23.04 12 Bridgestone Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 29 23.02 13 Bridgestone Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 36 23.01 14 23.01 15 23.01 • 16 • 23.01 17 23.01 18 23.01 19 23.01 20 23.01 Bridgestone EOLv Calc NAC.xls OUTPUT 2 • NAC EOL VOLTAGE CALCULATION ;CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office (503) 257 -7121 Fax Job Name: NIKE / BRIDGESTONE GOLF Job Address: 15675 / 15705 SW 72nd AVE TIGARD Job Number: • Conductor Wire Guage 14 Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F) 3.07 Date: 11/27/01 Cable Length In Feet (source to end of line) .492 Total Circuit Current 0.913 Nominal System Voltage 24 Panel Description: SILENT KNIGHT 5208 FACP M inimum Device Voltage 20.4 Panel No.: NAC 1.0 Output No.: 3 Point To Point Method EOLv I 22.38 I Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock End Of Line Method EOLv I 21.24 I Circuit Within Limits ? YES Load Centering Method EOLv I 22.62 I Circuit Within Limits ? YES Dev _ Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) EIC -,-. �.... » -- ' b., i7 iTM 'Y' '°Y'�; - � 't'Y.°3 �..°sm -ry , °-� �i„ I,, rvm� � a�+, ''bi; AV i ::. ' *�.,YR ',�. S `,. ,�i' ±h.,,s_ "x re4 ,. a .. ."^�,. ,:w " V kr�v`.E Aa ? a a ..r a i cIZItI f tT 1 FACP CLOSET DSM- 12/24 -R (1 CKT ONLY) NA 0.038 5 23.97 2 Nike Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 145 23.19 3 Nike Tenant AS- 24MCW -FW (30) H/S WHT 30 Cd 0.110 26 23.06 4 Nike Tenant RSS- 24MCW -FW (15) STB WHT 15 Cd 0.049 33 22.92 5 Nike Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 20 22.83 6 Nike Tenant AS- 24MCW -FW (75) H/S WHT 75 Cd 0.165 20 22.76 7 Nike Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 36 22.67 8 Nike Tenant RSS - 24MCW -FW (15) STB WHT 15 Cd 0.049 32 22.60 9 Nike Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd 0.072 32 22.53 10 Nike Tenant AS- 24MCW -FW (75) H/S WHT 75 Cd 0.165 95 22.40 11 Nike Tenant AS- 24MCW -FW (15) H/S WHT 15 Cd • 0.072 48 22.38 12 22.38 13 • 22.38 14 22.38 15 22.38 16 • 22.38 17 22.38 18 22.38 19 22.38 20 22.38 Bridgestone EOLv Calc NAC.xls OUTPUT 3 • NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503) 255 -9488 Office (503) 257 -7121 Fax Job Name: NIKE / BRIDGESTONE GOLF Job Address: 15675 / 15705 SW 72nd AVE TIGARD Job Number: Conductor Wire Guage I 14 I Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F) I 3.07 I Date: 11/27/01 Cable Length In Feet (source to end of line) I 6 I Total Circuit Current 0.12 Nominal System Voltage 24 Panel Description: SILENT KNIGHT 5208 FACP Minimum Device Voltage I 20.4 I Panel No.: NAC 1.0 Output No.: 4 Point To Point Method EOLv I 24.00 I Circuit Within Limits ? YES NAC Devices Mfg By: Wheelock End Of Line Method EOLv I 24.00 I Circuit Within Limits ? YES Load Centering Method EOLv I 24.00 I Circuit Within Limits ? YES Dev _ Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) 1 FACP CLOSET FCI SNAC NOTIFICATION P.S. NA 0.120 6 24.00 2 24.00 3 24.00 4 24.00 5 24.00 6 24.00 7 24.00 8 24.00 9 24.00 10 24.00 11 24.00 12 24.00 13 24.00 14 24.00 15 24.00 16 24.00 17 24.00 18 24.00 19 24.00 20 24.00 Bridgestone EOLv Calc NAC.xls OUTPUT 4