Loading...
Specifications SUBMITTAL FOR AN INERGEN FIRE SUPPRESSION SYSTEM AT 72 Ave. Office Building 13535 SW 72 Ave. Tigard, Oregon Oat CITY OF TIGARD Approved.».»....» ...... ».. »..... »....»....». »..» » ». Conditionally Approved, ): For omT Ne � X PERMIT 00 6 6 is PtO. See Letter to: Follow. .. »....» »... »». ». »...( ) Job Address: .7 05 . 3� B . (c) Ansul INERGEN Design Job Number. 6351 Ver 0 Designed By: JOHN A. GOKEY Company Name: ANSUL INCORPORATED Address: ONE STANTON STREET MARINETTE, WI 54143 USA Customer Name: Sanderson Safety Address: 1101 S. E. Third Ave., Portland, OR 97232 USA Phone Number. 503-889-3119 Fax Number. 503- 238 -6443 Contact.Name: Jerry Mollencop Description: Computer Room, C. Schiewe & Assoc., Inc. VOLUME CALCULATIONS AREA 1 computer room - Area Name: server Length (ft): 29.00 Width (ft): 16.92 Height (ft): , 9.50 Area (sq ft): 491 Volume (cu ft): 4661 Volume Reductions: Structural Reductions (cu ft): Reduced Volume (cu ft): 4661 ROOM MINIMUM AMBIENT TEMP (Fahrenheit): 70 DESIGN CONCENTRATION: 37.5 FLOODING FACTOR: 0.470 INITIAL INERGEN QUANTITY CALC. INERGEN Quantity (cu ft):I 2190.9 ALTITUDE CORRECTION Height Above or Below Sea Level (ft): 150 Factor. 1.00 ACTUAL INERGEN QTY (cu ft): L 2190.9 TOTAL INERGEN QTY (cu ft):I 2190.9 I CYLINDER REQUIREMENTS Cylinder Quantity. 5 Cylinder Size (cu ft): 439 INERGEN Agent Supplied (cu ft): , 2195 Page 1 of 2 Ansul INERGEN Design Job Number. 6351 Ver 0 Designed By: JOHN A. GOKEY Company Name: ANSUL INCORPORATED Address: ONE STANTON STREET MARINETTE, WI 54143 USA Customer Name: Sanderson Safety Address: 1101 S. E. Third Ave., Portland, OR 97232 USA Phone Number. 503 -889 -3119 Fax Number. 503- 238 -6443 Contact Name: Jerry Mollencop Description: Computer Room, C. Schiewe & Assoc., Inc. AREA 1 REQUESTED INERGEN AGENT PER AREA (cu ft):I 2195.0 INERGEN AGENT PER AREA (cu ft):I 2195.0 (From Fbw Calculation) ACTUAL INERGEN FLOODING FACTOR:1 0.471 CONCENTRATION RANGE CHECK: (Must be Between 37.5% - 42.8% For Ocpd. Spaces) Room Max Ambient Temp (Fahrenheit)f 74 Design Concentration at Max. Temp: 37.8 DISCHARGE TIME: Normal Ambient Temperature (Fahrenheit): 72 U Design Concentration at Ambient Temp.: 37.7 90% of Agent Discharge Time (Sec): 41.38 90% of Agent Discharge Time (Min): 0.69 ESTIMATED FLOW RATES: Estimated System Fbw Rate:1 2864 Estimated Orifice Union Pipe Size: J 1.25 Nozzle Quantity. I 1 Estimated Nozzle Flow Rate:( 2864 Estimated Nozzle Pipe Size: Pipe Length Factor (S = Short, L = Long): S Pipe Size (Inches): 1.25 Actual Discharge Time (Sec): 40.24 (from Nozzle Report) Open Area Required: Wall Strength: 5 Estimated Free Venting Area (Sq Inches): 328.6 Required Free Venting Area (Sq Inches): 337.9 (from Fbw Report Time) Page 2 of 2 Aaent Storaae Conditions Prepared By: JOHN A. GOKEY Company Name: ANSUL INCORPORATED Address: ONE STANTON STREET MARINETTE, WI 54143 USA Designer (sign name here): INERGEN Designer v1.2 UL:EX-4510 FM RC: (J.I.)2Y0A9A.F. ULC:CEx1151 Date: 3/30/01 9:43:45 AM Job Number 6351 Ver 0 Customer Name: Sanderson Safety Address: 1101 S. E. Third Ave., Portland, OR 97232 USA Phone Number: 503 -889 -3119 Fax Number. 503- 238 -6443 Contact Name: Jerry Mollencop Description: Computer Room, C. Schiewe & Assoc., Inc. Nozzle Performance Start End PipeSize Nozzle Code Cubic Feet Discharged 9 301 1 1/2 40 T .8594 2195 Total Cubic Feet of Inergen Discharged: 2195 Ninety Percent Discharged in Approximately: 40.24 Seconds Ninety Percent Discharge Pressure is Approximately: 195 PSI Jerry Mollencop on behalf of Sanderson Safety Supply Company Has completed a training course in • INERGEN Clean Agent Systems Training Date: January 19, 2000 Expiration Date: January 19, 2005 ANSUL RRE PROTECTION, MARINETTE, WI 54143-2542 715-735-7411 Be it known that Jerry Mollencop on behalf of • Sanderson Safety Supply Company has completed a training course in INERGEN Clean Agent Systems conducted by Msul Fire Protection instructors. This certificate is considered valid only if the above named individual is an employee of the Authorized Ansul Distributor Listed. Training Date: January 19, 2000 t Expiration Date: January 19, 2005 s` I f �� L n E I� i L' \I I; \ - ' In uctor 5:42)5; \ / it se,s� Manager of Training ANSUL ANSUL® MARIN FIRE PROTECTION MATERIAL SAFETY DATA SHEET . MARINE IR E, WI PROTECTION INERGEN QUICK IDENTIFIER (In Plant Common Name) Manufacturer's ANSUL FIRE PROTECTION Emergency CHEMTREC Name: Telephone No.: (800) 424 - 9300 Address: One Stanton Street, Marinette, WI 54143 - 2542 Other Information (715) 735 - 7411 Calls: Prepared By: Safety and Health Department Date Prepared: January 23, 1995 SECTION 1 — IDENTITY Common Name: (used on label) INERGEN CAS No.: N/A (Trade Name and Synonyms) Chemical Mixture of Inert Gases and Carbon Dioxide Chemical Inert Gases: Nitrogen, Argon Name: Family: Nonmetallic Oxide: Carbon Dioxide Formula: 52% N2, 40% Ar and 8% CO2 SECTION 2 — INGREDIENTS PART A — HAZARDOUS INGREDIENTS Principal Hazardous Component(s) (chemical and common name(s)): % CAS No. ACGIH TLV Acute Toxicity Data None PART B — OTHER INGREDIENTS Other Component(s) (chemical and common name(s)): % CAS No. Acute Toxicity Data Nitrogen 52 7727 -37 -9 N/A None Argon 40 7440 -37 -1 N/A None Carbon Dioxide 8 124 -38 -9 5000 ppm ihl -hmn LCLO 100,000 ppm/ 1 min SECTION 3 — PHYSICAL AND CHEMICAL CHARACTERISTICS (Fire and Explosion Data) Boiling — 320 °C Specific .084 lbs. /ft.3 Vapor Pressure 2205 psi ® 70 °F Point: Gravity (H20 =1): (mm Hg): Percent Volatile 100 Vapor Density 1 Evaporation Rate N/A Gas at room temperature. by Volume (%): (Air = 1): ( = 1): Solubility Slight Reactivity in N in Water: Water: Appearance Colorless gas with no odor. and Odor: Flash Point: None Flammable Limits N/A Extinguisher N/A Auto - Ignition N/A in Air % by Volume: Media: Temperature: Special Fire Though gas cylinders are equipped with pressure and temperature relief devices, they should be removed Fighting Procedures: from high temperatures or fire to avoid risk of rupture. Unusual Fire and None Explosion Hazards: SECTION 4 — PHYSICAL HAZARDS Stability: Unstable ❑ Conditions Stable ® to Avoid: None Incompatibility Does not apply (Materials to Avoid): Hazardous None Decomposition Products: Hazardous May Occur ❑ Conditions N/A Polymerization: Will Not Occur Oil to Avoid: SECTION 5 — HEALTH HAZARDS INERGEN (Continued) Threshold No TLV value cited, material can be an asphyxiant Limit Value: Routes of Entry: Non irritating gas Eye Contact: Skin Contact: Non irritating gas Inhalation: Not an asphyxiant at its normal design concentration of 34 — 70% V/V Ingestion: Non irritating gas Signs and Acute Overexposure: Dizziness, disorientation, loss of motor control Symptoms: Chronic Overexposure: Dizziness, disorientation, loss of motor control Medical Conditions Generally Not determined at this time. Suspect respiratory impairment. Aggravated by Exposure: Chemical Listed as Carcinogen National Toxicology Yes ❑ I.A.R.C. Yes E OSHA: Yes or Potential: Program: No X Monographs: No X No X SECTION 6 — EMERGENCY AND FIRST AID PROCEDURES Eye Contact: Avoid direct contact of high pressure gas discharge — use safety glasses. Skin Contact: Avoid direct contact of high pressure, cold gas with skin — wear gloves. Inhalation: Avoid direct inhalation of undiluted gas — gas mixture is an asphyxiant. Ingestion: N/A SECTION 7 — SPECIAL PROTECTION INFORMATION Respiratory Protection The normal discharge of INERGEN at its designed concentration between 34 — 70% V/V in a fixed en- (Specify Type): closure does not present any hazard. Any exposure outside of these limits should result in the use of self- contained breathing apparatus. Respirators will not function in 02 deficient atmospheres. Ventilation: Local As required Mechanical As required Exhaust: (General): Protective Loose fitting gloves of impermeable Eye ' Chemical goggles or safety glasses recommended. Gloves: materials such as leather. Leather Protection: work gloves are recommended when handling compressed gas cylinders. Other Protective None Clothing or Equipment: SECTION 8 — SPECIAL PRECAUTIONS AND SPILL /LEAK PROCEDURES Precautions to be Taken Normal precautions for handling high pressure gas in Handling and Storage: Other None Precautions: Steps to be Taken in Case None, material is a mixture of normal atmospheric gases Material is Released or Spilled: Waste Disposal Not applicable, material is a mixture of normal atmospheric gases. Methods: HAZARDOUS MATERIAL IDENTIFICATION SYSTEM RATINGS HAZARD INDEX: 4 Severe Hazard 1 HEALTH 3 Serious Hazard 2 Moderate Hazard 0 FLAMMABILITY 1 Slight Hazard 0 REACTIVITY 0 Minimal Hazard N/A = Not Applicable NDA = No Data Available • ANSUL and INERGEN are registered trademarks. ANSUL FIRE PROTECTION, MARINETTE, WI 54143 -2542 715- 735 -7411 Form No. F- 92130 -2 ©1995 Wormald U.S., Inc. Litho in U.S.A. ANSUL® INERGEN® FIRE EXTINGUISHING SUPPRESSION AGENT SYSTEMS DATA SHEET • APPLICATION that still allow a person to breathe in a ORDERING INFORMATION reduced oxygen atmosphere. It actually INERGEN® extinguishing agent used in INERGEN filled cylinders for use in Ansul engineered systems is particularly enhances the body's ability to assimilate engineered systems may be ordered in useful for hazards where an electrical, non- oxygen. The normal atmosphere in a room sizes of 200, 250, 350 ft. and 435 ft. contains approximately 21% oxygen and 3 3 conductive medium is essential or (5.7, 7.1, 9.9 m 12.3 m ) desirable; where clean -up of other agents less than 1% carbon dioxide. If the oxygen presents a problem; where hazard obstruc- content is reduced below 15 /o, most ordi- APPROVAL lions require the use of a gaseous agent; nary combustibles will not burn. INERGEN or where the hazard is normally occupied agent will reduce the oxygen content to INERGEN agent complies with the NFPA and requires a non -toxic agent. approximately 12.5% while increasing the Standard 2001, Standard for Clean Agent carbon dioxide content to about 4%. The Fire Extinguishing Systems and EPA Pro - The following are typical hazards protected increase in the carbon dioxide content gram SNAP, Significant New Alternate by INERGEN systems: increases a person's respiration rate and Policy. • Computer rooms the body's ability to absorb oxygen. Simply Agent is listed and approved by Under- stated, the human body is stimulated by writers Laboratories, Inc. (UL) and Factory • Subfloors the carbon dioxide to breathe more deeply and rapidly to compensate for the lower Mutual Research Corporation (FMRC). • Tape storage p y p Containers meet the applicable Department oxygen content of the atmosphere. PP � P • Telecommunications /Switchgear of Transportation (DOT) specifications. • Vaults PERFORMANCE • Process equipment INERGEN is an effective fire extinguishing ANSUL and INERGEN are registered trademarks. All normally occupied or unoccupied agent that can be used on many types of • All normally equipment fires. INERGEN extinguishing system units a reas very sensitive where electronic ctro or equipme nt id is are designed for total flooding protection against Class A surface burning, Class B ENVIROMENTAL IMPACT flammable liquid, and Class C fires occur- ring within an enclosure by lowering the INERGEN agent is a mixture of three natu- oxygen content below the level that sup - rally occurring gases; nitrogen, argon and ports combustion. carbon dioxide. As INERGEN agent is der- INERGEN agent has been tested by FMRC ived from gases present in the earths for inerting capabilities. Those tests have atmosphere, it exhibits no ozone depleting shown that INERGEN agent, at design con - potential, does not contribute to global centrations between 40% and 50 %, has warming, nor does it contribute unique successfully inerted mixtures of propane/ chemical species with extended air, and methane /air. atmospheric lifetimes. Because INERGEN agent is composed of atmospheric gases, it PHYSICAL PROPERTIES OF INERGEN does not pose the problems of toxicity associated with the chemically derived Specific gravity Halon alternative agents. 0.085 lbs. /cu. ft. (1.36 kg /m DESCRIPTION Vapor pressure 1925 psi c 32 °F F (132.7 bar @ 0 °C) INERGEN agent is a plentiful, non- 2175 psi @ 70 °F (149.9 bar @ 21 °C) corrosive gas that does not support com- 2575 psi @ 130 °F (177.5 bar @ 54 °C) bustion nor react with most substances. INERGEN agent contains only naturally- Vapor density occurring gases which have no impact on 1.1 (Air = 1) the ozone or the environment in general. Approximate molecular weight INERGEN agent is a mixture of three 34 inerting (oxygen diluting) gases: 52% nitrogen, 40% argon, and 8% carbon dioxide. INERGEN agent extinguishes fire by lowering the oxygen content below the level that supports combustion. When INERGEN agent is discharged into a room, it introduces the proper mixture of gases ANSUL FIRE PROTECTION MARINETTE, WI 54143 -2542 715 -735 -7411 Form No. F-9313-6 ©1995 Wormald U.S., Inc. Litho in U.S.A. ANSUL® System Components UL EX -4510 3 -1 -99 Page 1 -1.1 REV. 1 I n - CV-98 Valve /Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN® agent. A single Component Material Approvals cylinder may be used or multiple cylinders can be manifold - ed together to obtain the required quantity of agent for total Cylinder Steel Meets DOT flooding. The cylinder valve can be actuated electrically, 3AA2300 or pneumatically, and/or manually with approved valve actua- 3AA2015+ tion components. All valves are equipped with an anti- recoil Valve Brass feature. Safety Relief Valve Brass The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck Valve/Cylinder FMRC Approved of each cylinder. This cap entirely encloses and protects the Assembly UL Listed (EX -4510) valve while in shipment. Shipping Cap Steel The equivalent length of the valve is equal to 20 ft. (6.1 m) of 1/2 in. Sch. 40 pipe. Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 Ib. (kg) in. (cm) in. (cm) • Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) ' 217 (98) 59.7 (152) 10.7 (27.3) r 426620 LC -350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) L 426594 LC -425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435 (12.3) 439 (12.4) 260 (117.9) 65.5 (166.4) 11.3 (28.7) • Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) i 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC -425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 65.5 (166.4) 11.3 (28.7) ► Canadian TC Approved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 Ib. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426715 435 (12.3) 439 (12.4) 260 (117.9) 65.5 (166.4) 11.3 (28.7) t . Shipping Assemblies - Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426719 435 (12.3) 439 (12.4) 260 (117.9) 65.5 (166.4) 11.3 (28.7) CVUNDER A/ SHIPPING CAP 0 MN VALVE SHIPPING CAP GAUGE �� PRESSURE -. GAUGE r RECORD _■ VALVE • TAG l SAFETY 1 I _ VALVE RELIEF ■ 0 f HEIGHT TO OUTLET CENTER A / \\\ • .."\o. 002251 O02232 CV-98 INERGEN Valve The CV valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed • closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. NOTE: Use Flexible Discharge Bend, Part No. 842424, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are registered trademarks. ANSUL INCORPORATED. ONE STANTON STREET. MARINETTE. WI 54143 -2542 715-735-7411 Form No. F- 9877 -1 01999 Ansul Incorporated litho in U.S.A. ANSUL® System Components UL EX -4510 11 -1 -99 Page 1 -12 In � REV.4 rrcomnua.o j ® .�.n Flexible Discharge Bend Description • The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra -heavy flexible hose which con- Shipping Assembly nects the valve discharge outlet to the fixed piping or head- Part No. Description er manifold. The discharge bend has a special female 427082 Flexible discharge bend • thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. 842430 Washer • The discharge bend will withstand a pressure of 9000 psi - • (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built -in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. Thread Size/Type Component Material Valve End Manifold End Approvals • 5/8 in. Flexible SAE 100 R2 Special to 1/2 in. NPT Male FMRC Approved ( • Discharge Bend Type AT mate with UL Listed (EX -4510) • CV90 and CV -98 Valve • 18 7/8 IN. (47.9 cm) FEMALE ADAPTOR 12 IN. NPT (BRASS) WASHER MALE COUPLING CHECK SWAGE ON mi p: /Ace ; / /! "�• \ \` �.- �.�.�.�... •... . �� VALVE END MANIFOLD/ENO 111101.1 s \ ���\�.� � �� �r= 7111■1 — • wiwows ANSUL and INERGEN are registered trademarks iIhn in U.S.A. ANSUL® System Components UL EX -4510 3 -1 -99 Page 1 -2.1 REV. 1 . In - vi:en CV-98 Electric Actuator Description • Electrical actuation of a CV-98 INERGEN valve is accom- 1 1/8 - 18 plished by a CV-98 electric actuator interfaced through an CP AUTOPULSE Control System. This actuator can be used in ) hazardous environments where the ambient temperature range is between 32 °F to 130 °F (0 °C to 54 °C). The elec- t tric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A 1/2 IN. maximum of two CV-98 electric actuators can be used on a ra C C► N��B single AUTOPULSE release circuit. When using either one or two CV-98 electric actuators, an in -line resistor, Part No. C ssns IN. 426001, must always be used. fi `�` �s.s cm) CAUTION The Actuator Shipping Assembly contains: 23 ohm resis- LABEL tor, (2) female connectors, and instruction sheet. The actuator specifications are: \ � Nominal Voltage _ / 24 VDC @ 1.5 amps 1 IN. ) ~/ 11/8 -18 In auxiliary or override applications, a manual cable pull 00139S i , actuator can be installed on top of the CV-98 electric actuator by removing the safety cap. The METRON PROTRACTOR must be replaced after Three manual lever actuators are available for use with • discharge of the INERGEN system. the CV-98 electric actuator: Part No. 423309, 423310, and 423311. Shipping Assembly The actuator contains a standard 1/2 in. threaded female Part No. Description straight connector for electrical conduit hookup. The CV -98 electric actuator uses a replaceable 423684 CV-98 Electric Actuator METRONe PROTRACTOR which is a device designed to 423958 Replaceable METRON produce a high force mechanical output. The actuator is PROTRACTOR electrically actuated and will operate within milliseconds. Component Material Thread Size/Type Approvals CV -98 Electric Actuator Body: 1/2 in. Straight Female UL (E91021) Brass on Conduit Connection FM Approved METRON PROTRACTOR Plunger: Stainless Steel ___ ___ ..... .,_ ,......—,� 1 fine in U.SA ANSUL® System Components UL EX -4510 4 -1 -94 Page 1 -15 REV. 1 Inercen. Orifice Union Description The orifice union is required to restrict the flow of INERGENTM agent thus reducing the agent pressure down stream of the union. The 3000 psi (20685 kPa) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.' The orifice plate provides readi- ly visible orifice identification. The orifice union is avail- ® • i .4 able in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., 7 and 2 in. NPT. 4111110 ' ,If ' I r 404 . 1 0 Shipping Assembly * , �l' Part No. Description ' \! - t 416677 . 1/2 in. NPT orifice union OF FLOWN t i 416678 3/4 in. NPT orifice union tap 1 416679 1 in. NPT orifice union i 416680 1 1/4 in. NPT orifice union I 416681 1 1/2 in. NPT orifice union VISIBLE ORIFICE IDENTIFICATION 416682 2 in. NPT orifice union Component Material Thread Size Approvals Orifice Union Body: Forged 1/2, 3/4, 1, FMRC Approved Steel 1 1/4, 1 1/2, UL Listed (EX -4510) 2 in. NPT Orifice Plate: Stainless Steel ANSUL is a registered trademark and INERGEN is a trademark. 'Orifice diameter must be specified when placing order. NOTE: For larger sizes. contact Ansul Applications Engineering Department for availability and Part No.. .. ______ ... �..... ..e. ... l-= le.= 7w44 a ■•••• u.. c_ev.._o n.oaa Wnnnnli II C Inr lithe in 11 . S.A. ANSUL® System Components UL EX -4510 5 -1 -00 Page 1 -18 'n em REV.2 oft &Mau bee Pressure Switch — DPST Description The pressure switch is operated by the INERGENTM agent The pressure switch can be installed either before or after pressure when the system is discharged. The pressure the pressure reducer in the distribution piping. switch can be used to open or close electrical circuits to • Minimum operating pressure is 50 PSI (3.5 bar). either shut down equipment or turn on lights or alarms. The double pole, single throw (DPST) pressure switch is con- structed with a gasketed, water tight housing. The housing Shipping Assembly is constructed of malleable iron, painted red. A 1/4 in. NPT Part No. Description pressure inlet is used to connect the 1/4 in. pipe from the 846250 Pressure switch — DPST INERGEN system. Component Material Thread Size/ Type Electrical Rating Approvals Pressure Switch Switch: ` Conduit Inlet: 3/4 in. NPT Female 2 HP — 240 VAC/ FMRC Approved DPST BAKELITE Pressure Inlet: 1/4 in. NPT Female 480 VAC UL Listed (EX -4510) Housing: 2 HP — 250 VDC, Malleable 30A — 250V AC/DC Iron 5A — 480V AC/DC Piston: Brass Cover. Brass 3 5/B IN. ~ — (92 cm) • MALLEABLE IRON BRASS RESET 2 7/6 IN. FINISH - RED PAINT �-e PLUNGER ~ — (7.3 cm) TO ELECTRICAL \ • EQUIPMENT TO \ \` MOISTURE-PROOF BE CONTROLLED JOINT a � �� • `§ GASKET NUT � _ —� '0' RING GASKET O O .__. 11111H1 � NAMEPLATE DOUBLE POLE - — HEAVY DUTY 4 9/16 IN. TOGGLE SWITCH (tt.5 cm) WITH FULLY . I \ o \ BAKEOTE BASE 1121 ` ; 1 ENCLOSED II � BRASS PISTON I � Z • PISTON `0' RING O O �� yiiiiii ; - GASKET TO ;'. POWER 3/4 1N. r i.. —I ‘-- tEr r 1 ELECTRICAL ,—rL - — I . CONDUIT OUTLETS 14 _ _... LI 1/4 IN. UNION —e- • 1 /41N. PIPE J FROM CYLINDERS �< CO37 , I1 BAKELITE is a trademark of Union Carbide Corp. ANSUL is a reentered trademark and INERGEN is a trademark ANSUL INCORPORATED. ONE STANTON STREET, MARINETTE, 1M 541432542 715-735-7411 Form No. F-9327-4 02000 Maul Incorporated Una in U.S.A. ANSUL System Components UL EX -4510 12 -1 -93 Page 1 -23 I ® Warning Plate — Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area Shipping Assembly when the alarm sounds. The warning plate is furnished with Part No. Description four mounting holes for ease of installation. The plate is 416265 Warning Plate — inside room constructed of aluminum. with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (.64 cm) FMRC Approved UL Listed (EX -4510) r " 12.00 - 1 0 1 O WHEN ALARM SOUNDS VACATE AT ONCE INERGENTM AGENT 7.00 BEING RELEASED In - n -• = - . O LABEL NO.416265 O 002746 ANSUL is a registered trademark and INERGEN is a trademark. c.,.,., NetF.aarsa 8r4aa wwmamtl.S_ Inc. Litho nU.S.A. ANSUL System Components UL EX -4510 5 -1 -00 Page 1 -24 REV. 1 In �� Warning Plate — Outside Room Without Alarm Description The warning plate is available for mounting outside the hazard area to warn the personnel that the space is pro- Shipping Assembly tected by an INERGENTM system and no one should enter Part No. Description after a discharge without being properly protected. The 416266 Warning Plate — outside warning plate is furnished with four mounting holes for ease room of installation. Component Material Mounting Hole Size Approvals • Warning Plate Aluminum 7/32 in. (.56 cm) FMRC Approved UL Listed (EX -4510) f- 8.00 j O • W ARNING THIS SPACE IS PROTECTED BY AN INERGENTM FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. 7.00 DO NOT ENTER WITHOUT APPROVED SELF - CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. In - n FIFIZ WOOGINS. MG 11147 AGENT LABEL NO. 416266 CO • (.' 002147 ANSUL and INERGEN are registered trademarks. ANSUL System Components UL EX -4510 3 -1 -99 Page 1 -16.1 REV. 1 ifle(ft ., 180° Discharge Nozzle Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- Shipping Assembly ders. Ten sizes of nozzles are available. The system design Part No. Description specifies the orifice size to be used for proper flow rate and 426138 1/4 in. NPT nozzle distribution pattern'. The nozzle selection depends on the 426139 3/8 in. NPT nozzle hazard and location to be protected. The 180° nozzle is 426140 1/2 in. NPT nozzle commonly used when nozzle placement is at the wall. 426141 3/4 in. NPT nozzle Standard nozzles are constructed of brass. 426142 1 in. NPT nozzle An index mark is stamped on the bottom of the nozzle to 426143 1 1/4 in. NPT nozzle indicate the aiming direction. 426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle Component Material Thread Size 426145 2 1/2 in. NPT nozzle Nozzle Body: Brass 1/4, 3/8, 1/2, 3/4, 1, 426146 3 in. NPT nozzle 1 1/4, 1 1/2, 2, 21/2,3NPT UL/ULC Part Orifice • Size No. Range — In. 1/4 in. 426138 .073 to .255 e 3/8 in. 426139 .099 to .345 I - 1 /2 i n. 426140 426141 .124 to .435 / � .� 3/4 in. .165 to .577 ° ` 1 in. 426142 426143 .210 to .734 to .966 I .276 . 1 1/4 in. (� 1 1/2 in. 426157 .322 to 1.127 2 in. 426144 .388 to 1.550 r� INDEX 2 1/2 in. 426145 .465 to 1.852 MARK 3 in. 426146 .580 to 2.301 002742 Size A -In. B -In. C-In. /h., 1/4 in. 5/8 1 9/16 21/32 • � 3/8 in. 3/4 1 5/8 23/32 1/2 in. 15/16 1 31/32 27/32 7/8 3/4 in. 1 1/8 2 5/32 , 1 in. 1 13/32 2 9/16 1 22.5% 1 1/4 in. 1 3/4 2 3/4 1 1/16 1 1/2 in. 2 2 31/32 1 1/16 2 in. 2 3/8 3 1 \ ."-- 002743 2 1/2 in. 3 3 1/2 1 3 in. 3 1/2 4 1/8 1 1/4 A s ... • Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. • ANSUL and INERGEN are registered trademarks. ANRl 11 INOY1RPfRA7Fn ONE STANTDN STREET MARINIFTTE. WI 54143 ?Sd? 7157.'787111 :.nnn Nn F.0002n (1990 anc, 1 Innmmetmtan I ifhn in Ll.3.A ANSUL System Components ► UL EX -4510 3 -1 -99 Page 1 -16.2 w In - .. n ( n n u me.o g .r r Nozzle Deflector Shield Description The INERGEN® system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. Component Material Approvals The deflector shield helps keep the agent discharge away Nozzle Steel FMRC Approved from false ceiling tiles and fragile light fixtures, avoiding Deflector UL Listed (EX -4510) damage to them. Shield The deflector shields are constructed of steel and painted with a cameo cream colored paint. They are available in five sizes. Shipping A B C D E Assembly Inlet Length of Overall Deflector Coupling Part No. NPT Coupling Length O.D. O.D. 417708 1/2 in. 1 7/8 in. 3 in. 3 3/8 in. 1 1/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2 in. 3 1/4 in. 3 3/8 in. 1 3/8 in. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) � 417714 1 in. 2 3/8 in. 3 13/16 in. 4 7/8 in. 1 3/4 in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 11/4 in. 25/8 in. 43/16 in. 47/8 in. 21/4 in. (6.7 cm) (10.6 cm) (12.4 cm) (5.7 cm) 417720 1 1/2 in. 3 1/8 in. 4 29/32 in. 5 21/32 in. 2 1/2 in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) • NOTE: There are no deflector shields available tor the 2.2 1/2. or 3 in. models. E A 1 8 C ‘41881 003651 o� ANSUL and INERGEN are registered trademarks. wwma ua.nnmawtcn nwic crw w.rnwcro¢r wwwournr un ew. wn ..�.n - ..�- .n��... .. .._ - ........ --- . .. __ _._, ANSUL.® System Components UL EX -4510 11 -1 -95 Page 1 -17 i rl =sr% n. REV.4 Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing com- Component Material Approvals ponents are constructed of heavy structural steel. Bracket Bracketing Steel FMRC Approved assemblies are available in modules for two to six cylinders UL Listed and can also be connected together for any combination (EX -4510) over six. Bracketing can be assembled to support single - - row, double row or back -to -back rows of cylinders. Bracketing components are painted with a red enamel coating. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) ► 845122 350 ft.3 (9.9 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) I. 845245 350 ft.3 (9.9 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) , 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright (used either for right or left side) 873553 Single row or back -to -back row bracket foot (left side) 873554 Single row or back -to -back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 873256 Center upright (required when connecting seven or more cylinders in a row) 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) cylinders) • 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) cylinders) • 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) r Multi- Cylinder Single Cylinder f� ( UPRIGHT F4 J \ 4211' A gl A.... t1, ( 47.\ \ . iii. t 11 I J t \ I I I I ( BACK FRAME l I I I I ( ��� CYLINDER CLAMP t I I I I II _�►4 I ���► �/ / I I� ;�\ CARRIAGE BOLT 1 WITH NUT I I I I I I 1 I j CLAMP RIGHT I I I BRACKET FOOT 1 I CHANNEL I I ../ I I I I \_ I — .,‘, Imo ___ ,. '1 \ LEFT BRACKET FOOT ANSUL and INERGEN are registered trademarks. 1 ANSUL INCORPORATED, ONE STANTON b 1 Htt i. MARINETTE, WI 54143 -2542 715- 735.7411 Form No. F- 9309 -4 01995 Ansul Incorporated Litho in U.S.A. A ; PASUL. DETECTION AND AUTOPULSE ®4428 CONTROL AGENT EQUIPMENT RELEASING ( DATA SHEET CONTROL UNIT FEATURES • General Alarm And Trouble Relays • Steel Cabinet 14 in. (36 cm) Wide x 16 in. • Complies with: • Optional Module For 4 Zone /Function (41 cm) High x 5 in. (13 cm) Deep NFPA 71 Central Station Signaling Relays (4XZM) • Dead -Front Dress Panel Option Systems • Optional Transmitter Module (4XTM) • Trim Ring For Flush Mount Between 16 in. NFPA 72 Local, Auxiliary, Remote • Optional Volt/Amp Meter Module (4XMM) (41 cm) Center Studs (TR -4XR) Station, and Proprietary Protective • Optional Supervised Remote Annunciator DESCRIPTION Signaling Systems (RZA -4X). Requires LED Interface Module NFPA 12 CO2 (High pressure only) (4XLM) The AUTOPULSE 442R is a cost effective Extinguishing Systems detection and releasing control unit utilizing • Optional digital communicator conventional wiring methods for protection of NFPA 12A Halon 1301 Extinguishing (NOTI•FIRE 911) a single hazard area. Cross zone detection Systems • Disable /Enable Controls Per Initiating Zone with programmable time delays and abort NFPA 12B Halon 1211 Extinguishing • Battery /Earth Fault Supervision capability, immediate manual actuation, two Systems alarm circuits, two release circuits, alarm and NFPA 2001 Clean Agent Fire • Last Event Recall Feature to Identify trouble relays, and auxiliary 24 VDC make Intermittent Trouble Conditions this a very flexible control unit ca able of Extinguishing Systems rY P • Microprocessor - Controlled • RMS Regulated 24 VDC Output Power, releasing INERGEN, Carbon Dioxide, and 2.25 Amperes Dry Chemical fire suppression systems. • Power limited on All Circuits Except • 7.0 AH to 15 AH Battery Options, Up To 90 Municipal Box output Circuits Hours Standby • Alarm And Trouble Resound INPUT CIRCUITS: • 230 VAC, 50 Hz International Option ( .. • 2 Initiating Circuits (Style B /D) 1. Detector Zone 1 (Style B /D) • 4 -Wire Detector Resettable Power Output • Abort Switch Input Circuit (Style B /D) 2. Detector Zone 2 (Style B /D) • Non - Resettable Regulated 24 VDC Power • Manual Release Input Circuit (Style B /D) Output 3. Abort (Style B /D) • Supervisory Input Option (Style B) • Extensive Transient Protection 4. Manual Release (Style B /D) • 2 Indicating Appliance Circuits (Style Y/Z) • Watchdog Timer to Supervise 5. Supervisory (Style B) • 2 Release Circuits (Style Y) Microprocessor OUTPUT CIRCUITS: • Cross -zone Option • Output Circuits Protected Against False 1. Indicating Circuit 1 (One Zone In Alarm) • Delay Timer: 0, 10, 20, or 30 Seconds. Activations By 2-Ste p Command Sequence 2. Indicating Circuit 2 (Pulse With 2 Zones • Special Abort Options For IRI, New York • Slide -In Labels For Zone Identification • In Alarm And Sound Steady On City, And Other Local Jurisdictions Release) • Distinct Audible Indications For: 1 Zone in 3. Releasing Circuit 1 Alarm; 2 Zones in Alarm; Release 4. Releasing Circuit 2 AutoPulse. 442R + . i . :: . f t .: ,s, ., _„ ----r __— .4 I 1 it� tii-ta li .:,.° .l y �11 j W. r. 3I i - I i[5 P 1 . , 1 1 111-1 rI iCI 7 ® :; i I r " � :" I •,.�. r�.,.� .,r� � is ( G ANSUL. I FRONT PANEL CONTROL SWITCHES: • Short circuit current: 40 mA maximum Field Program Selections: 1. Switch 1 Tone Silence • Maximum detector current in standby: 2 6- position dip switch to select: 2. Switch 2 Alarm Silence milliamps (peak) per zone • Cross Zone Operation 3. Switch 3 Alarm Activate •Maximum loop resistance = 200 ohms • Supervisory Input 4. Switch 4 System Reset •End of -line resistor: 4.7 K, 1/2 watt • Delay Time: 0, 10, 20, or 30 seconds • Detector loop current is sufficient to ensure • Abort Mode . . Optional Boards operation of one alarmed detector per zone The Ansul AUTOPULSE 442R Control Unit • Supervisory current: 5 mA. Cabinet Dimensions has mounting slots for two option boards. Door: 16.125 in. High x 14.625 in. Wide (40.9 Indicating/Releasing Circuits cm x 37.2 cm Any two of the three option modules may be cm) installed: • Power - limited circuitry Backbox: 16.0 in. High x 14.5 in. Wide x TRANSMITTER MODULE (4XTM): • Maximum voltage drop due to wiring: 4.75 in. Deep (40.6 cm x 36.8 cm The Transmitter option provides a supervised 2 VDC x 12.1 cm) output for local energy municipal box trans- • Voltage: 24 VDC RMS regulated (not Cabinet: 5.375 in. Deep (13.7 cm) mitter (for NFPA -72 Auxiliary Protective filtered) LISTINGS AND APPROVALS Signaling System) and alarm and trouble • Total current to all external devices: 2.25 UL S4935 reverse polarity (for NFPA -72 Remote amps max S Station Protect Signalng System). Also (Listed for Manual and Automatic Fire Alarm r ive ig . A ti ond a D S s S and ) Al o • Maximum signaling current per circuit: Service. Suitable as Releasing Service trouble LED. A jumper option allows the 1.5 amps Control System) reverse polarity circuit to open with a System • End -of -Line Resistor = 4.7 K, 1/2 watt ULC CS412 Trouble condition if no alarm condition exists. Alarm and Trouble Relays FMRC Approved LED INTERFACE MODULE (4XLM): • Dry Form -C contacts rated for: CSFM Approved The module supports the RZA -4X Remote 2.0 amps 1 30 VDC (resistive) MEA Approved Annunciator module. The module mounts to 0.5 amps @ 30 VAC (resistive) (City of New York) the main board occupying one of the two Digital Communicator NOTI•FIRE 911: European Community option connectors. LED wiring is supervised For Central Station service: (NFPA 71 Conformity Approved for opens. Faults will activate System Central Station Protective Signaling System) (220VAC Model) Trouble condition. or Remote Station Service (NFPA 72 Remote ORDERING INFORMATION ZONE RELAY MODULE (4XZM): Station Protective Signaling System) Approximate The Zone Relay module provides Form -C Transmitter Module (4XTM) Shipping general alarm and trouble contacts and the Weight following Form -C relays: For Local Energy Municipal Box service Part No, Description Jb, (kgl One detector in alarm (NFPA -72 Auxiliary Protective Signaling Two detectors in alarm System): 417696 AUTOPULSE 442R, 25 (11.3) Releasing Circuit 1 Activated • Supervisory current: 5.0 mA Agent Releasing Con Releasing Circuit 2 Activated • Trip current: 0.35 amps. (Subtracted from 120 trol Unit, Red, ^ NOTE: Relays can be silenceable/non- Indicating Appliance power):'' 417697 AUTOPULSE 442R, 25 (11.3) , silenceable by jumper option. • Coil Voltage: 3.65 VDC Agent Releasing REMOTE ANNUNCIATOR (RZA -4X): • Coil resistance: 14.6 ohms ' Control Unit, Red, The Remote Annunciator mounts on a stan- • Total wire resistance between panel and 230 VAC dard single -gang box and provides the fol- trip coil = 3 ohms 417692 Battery Pack, 7 AH, 15 (6.8) lowing: 24 VDC For Remote Station service (NFPA -72 System Trouble LED (yellow) Remote Station Protective Signaling 417693 Battery Pack, 12 AH, 22 (9.9) Local Piezo Sounder System): 24 VDC Silence Switch (for local sounder) • Maximum current allowed for both circuits 417475 TR -4XR, Trim Ring 2 (0.9) Indicating Circuit 1 LED (red) shall not exceed 10 mA per circuit. for Semi -Flush Indicating Circuit 2 LED (red) Mounting, Red Releasing Circuit 1 LED (red) • Reverse polarity output voltage = 24 VDC. Releasing Circuit 2 LED (red) 417472 4XMM, Ammeter - 2 (0.9) 9 ( ) Zone Relay Module (4XZM): Voltmeter Module NOTE: The Remote Annunciator requires Dry, Form -C contacts rated for. l R Zone Relay use of an LED Interface module 2.0 amps 0 30 VDC (resistive) 417881 4XZM, y 2 (0.9) Optional Meters 0.5 amps 0 30 VAC (resistive) Module F our -wire Smoke Detector Power Output 417882 4XLM, LED Interface 2 (0.9) VOLTAGE AND CURRENT METER Module (4XMM): Terminals: - Up to 200 mA of current is available for 4- . 417883 . RZA -4X, Remote 2 (0.9) The 4XMM provides a voltmeter to measure wire t t smoke detectors. Annunciator the voltage across the batteries and an 417470 4XTM, Plug In 2 (0.9) ammeter to measure the charging current to RMS Regulated 24 VDC Power Output Transmitter Module, the batteries. The meters are provided as an Terminals: Tr Tr Municipal Box and assembly that mounts to the lower left -hand Total DC current available for wens Po g Remote Station comer of the cabinet. external devices is 0.5 amp (subtracted from Connection SPECIFICATIONS indicating appliance power dedicated to all 417890 Dress Plate, 2 (0.9) AC Power output circuits). Full Length Dead • 120 VAC, 60 Hz, 1.2 amps Non - resettable 24 VDC Power Output Front (ULC and FM) • Wire size: 14 AWG with 600 V insulation Terminals: Initiating Circuits Total DC current available from this output is up to 200 mA (subtracted from four -wire • Power - limited circuitry smoke power). • Operation: Style B (Class B) /Style D (..L:.'. (Class A) • Standby voltage: 24 VDC (ripple = 10 mV ANSUL, AUTOPULSE and INERGEN are registered peak -to -peak) trademarks. • Alarm current: 15 mA minimum ANSUL INrYIRPORATED. ONE STANTON STREET. MARINETTE. \M 54143 - 2542 715- 735 -7411 Form No. F- 94124-1 01998 Ansul Inmrnoratart Litho in U.S.A. ANSUL Detection and Control Components / J 4XZM Zone Relay Module Description Ordering Information The 4XZM Zone Relay Module is an optional module with Shipping zone /function relays for use with the AUTOPULSE® 442R Weight and AUTOPULSE 442D control systems. Listings for this Part No. Description Ib. (kg) module are under the control unit. 417881 4XZM Zone Relay Module 0.5 (0.23) The Zone Relay module provides Form -C general alarm and trouble contacts, plus four Form -C relays that activate with ANSUL and AUTOPULSE are registered trademarks. each of the four output circuits. These relays can be silenced/non- silenced by jumper option. Technical Information Dry, Form -C contacts rated for: 2.0 amps © 30 VDC (resistive) 0.5 amps © 30 VAC (resistive) 4XZM ZONE RELAY MODULE 21/2 IN. 1 ~ (64 mm) I • I 0 1, © 2 1 NO1 0 NC ) RELAY #1 —Q— I 0 3 C 0 - 4 NO 0 5 NC RELAY #2 I— 0 6 C P i V, I —1=— , I 0 7 NO 8 NC RELAY #3 9 C 4 IN I NO (102 mm) I % 11 NC RELAY #4 0 12 C 1 0 - 13 NO 1 0 14 NC ALARM —�' 0 15 C Pii I I 0 16 NO 0 17 NC TROUBLE 0 ' O 18 C RELAY 81 THROUGH 04 WILL ACTIVATE WITH OUTPUT 01 THROUGH 04 AND REMAIN LATCHED CUT JUMPER FOR NON- 1 UNLESS JUMPER LATCHING (SILENCEABLE) USE DISABLE SWITCH TO 'LATCH' IS CUT RELAY OPERATION DISCONNECT THE RELAYS : 3 -2 ANSUL INCORPORATED. ONE STANTON STREET MARINETTE, WI 54143 -2542 715. 735.7411 Form No. F -9579 ©1995 Ansul Incorporated Litho in U.S.A. ANSUL® Detection and Control Components (AMPLfirte- . _. PS Series Batteries Features CHARACTERISTIC DISCHARGE CURVES • Provide secondary power for control units 6.5 -13 • Gelled electrolyte -- • Sealed and maintenance free W 6.0 . 12 —__ �� • Overcharge protected o 5.5 .- 11 - • Extended shelf life > 5.0 -10 _ o.175C0.1C • Easy handling with leak -proof construction W ,' 0.25C • Ruggedly constructed, high - impact ABS plastic case < 4.5 .- 9 ' 0.6C • Long service life 4.0 - 8 � • Compact design 3c -— 2C 1c ' 0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 Applications [—MINUTES ►I-4— HOURS —el PS series batteries provide secondary power for the DISCHARGE TIME @ 68 °F (20 °C) AUTOPULSE® control systems. Use these batteries to pro- vide backup power for control units. Select batteries based on current requirements for your system and the capacity of EFFECT OF TEMPERATURE ON CAPACITY its charger. These batteries can be used over a temperature 120 range of –76 °F to +140 °F ( -60 °C to +60 °C). • Description 100 � - - -- 0.1c . ., . The sealed construction of the battery allows trouble -free, • - -- 0.25C safe operation in any position. There is no need to add elec- o w� -- - -o.sc trolyte, as gases generated during overcharge are recom- Q 11.2 M ----�c bined in a unique "Oxygen Cycle." The battery is sealed, m leak- proof, and maintenance free. The case is made of ABS, < 40% �� a high- impact plastic resin (acrylonitrile butadiene styrene o copolymer) with high resistance to chemicals and flam- �, 20°i mability. ,.- Shipping assemblies consist of two (2) 12 VDC batteries pro - 0% - viding 24 VDC to the control system when connected in -4° 14° 32° 50° 68° 86° t04° 122° 140° ( - 20 ° ) ( -1 0 ° ) (0 ( ° ) (20 ° ) (30 ° ) ( ° ) (50 ° ) (60 series. TEMPERATURE °F ( °C) Technical Information The capacity of a battery is the total amount of electrical energy available from a fully charged cell. Its value depends PS SERIES BATTERIES on the discharge current, the temperature during discharge, the final cutoff voltage and the general history of the battery. + Capacity expressed in ampere -hours (AH), is the product of the current discharged and the length of discharge time. The rated capacity (C, where C = rated Capacity of the battery in AH) of the PS series batteries is measured by its perfor- r mance over 20 hours of constant current discharge at a tem- J 1 ¢ t perature of 68 °F (20 °C) to a cutoff voltage of 1.72 volts, per 1 cell (10.32 V on a 12 V battery). For example: Model SEALED RECHARGEABLE = o z PS -1242, with a rated capacity of 4.0 AH, will deliver 200 BATTERY W = cr milli -amps (1/20 of 4 AH, or 0.05C) for 20 hours before the voltage drops to 10.32 V (1.72 x 6 cells). I mo — LENGTH ►I WIDTH —►I 3 -46 Technical Information (Continued) Rated 20 Hour Height over Capacity Discharge Length Width Height Terminal Weight 20 Hour Rate in. in. in. in. Ib. Model Rate (AH) (mA rate) (mm) (mm) (mm) (mm) (kg) ..' .,, PS -1242' 4.0 200 3.54 2.76 3.98 4.13 3.8 (90) (70) (101) (105) (1.7) PS -1270 7.0 325 5.94 2.56 3.70 3.86 5.7 (151) (65) (94) (98) (2.6) PS -12120 12 600 5.94 3.86 3.70 3.86 8.8 (151) (98) (94) (98) (4.0) PS -12170 17 850 7.13 2.99 6.57 6.57 12.8 (181) (76) (167) (167) (5.8) PS -12250 25 1300 6.89 6.54 4.92 4.92 18.7 . (175) (166) (125) (125) (8.5) PS -12600 55 3000 10.25 6.60 8.20 9.45 39.7 (260) (168) (208) (240) (18.0) Note: Individual batteries have a nominal voltage of 12 volts. Ordering Information Shipping Weight Part No. Model No. Description Ib. (kg) 68709* PS -1242 PS Battery Pack, 8 (3.6) 4.0 AH, 24 VDC 417692 PS -1270 PS Battery Pack, 12 (5.4) 7.0 AH, 24 VDC ;;,; 417693 PS -12120 PS Battery Pack, 18 (8.2) , 12 AH, 24 VDC 417694 PS -12170 PS Battery Pack, 26 (11.8) 17 AH, 24 VDC 417695 PS -12250 PS Battery Pack, 40 (18.1) 25 AH, 24 VDC 417997 PS -12550 PS Battery Pack, 84 (38.1) 55 AH, 24 VDC • Supplied with wire harness; battery for use with AUTOPULSE FOUR only. ANSUL and AUTOPULSE are registered trademarks. e 's,.:.: ' .1.:'''1:. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143 -2542 715- 735 -7411 Form No. F - 95122 - ©1998 Ansul Incorporated Litho in U.S.A. 05/21/01 MON 14:07 FAX 715 732 3479 TSS • Z002 ONSUL® Detection and Control Components anM ■............OM.......•••..... •• 11 U I. ■ • ... • • ■M •1 • .., A. t• N ■ II IN' ' M t . " SIJ- 24 1onlzation Smoke Detector Features , DIMENSIONS – NS6 -224 BASE -.— 1 7/81N • Highly stable operation, RF/Transient protection TO 4 IN. SQUARE 7/18 IN. r _ ( mm) OR 4 1N. OCTAOON (11 mm) • Low standby current, 40NA at 24 VDC OUTLET 90X • Two built -in power /alarm LEDs for 360° viewing -y • Non - directional smoke chamber o 1�;�; o 5 7/e IN. ■ • Vandal resistant security locking feature (149 mm) , • Built -in magnetic detector sensitivity test feature meets r 7 � NFPA 72, Chapter 7 Inspection Testing and Maintenance 0 ,,, cow.. • Compatible with SLR -24 photoelectric detectors • Backwards:compatible with SLK and SIH smoke detectors DIMENSIONS – NS4 -224 BASE _ ins IN • 5118 IN. (47 IN _al Applications Tog N1. 0 mm) The SIJ -24 Ionization Smoke Detectors are Intended for use OCT ETONBOX in commercial, industrial, and institutional buildings. The ��y detectors are placed primarily in clean, Indoor environments �,- where early waming fire detection is required. ��� t00 's/18 �� � ( IN; The detectors are used in combination with an Ansul ` AUTOPULSEe Control System and an Ansul fire suppression V• system for automatic detection, alarm, equipment control, and fire suppression system release capabilities. COME 00.41:1. The SIJ -24 ionization smoke detector utilizes two bl -color LEDs for status indication purposes. In a normal standby DIMENSIONS – HSB-21 BASE condition the LEDs flash Green approximately once each t• * t lute IN second. When the detector senses smoke and goes into TO 4 IN. SOUARE OUTLET BOX 9/16 IN. (49 mm) alarm the status LEDs will latch on Red, remaining lit until the detector is reset. The design of the detectors allows use In a wide range of I humidities, temperatures, and air velocities. fi` s ve IN. Ill ( ' ,d'J (toe mm Description . A single radioactive source of Americium -241 Ionizes two ■ chambers within the detector, a reference chamber, and the TO S OR 4 IN. CC'••° smoke - sensing chamber. The air is ionized by this source and OCTAGON OUTLET BOX a small DC current flows between the electrodes of each chamber. Smoke can freely enter the sensing chamber while the inner chamber Is virtually sealed to smoke. Smoke enter- DIMENSIONS – HSC -224RA BASE ing the sensing chamber causes a reduction In the DC current 121/2 IN. /B IN. (63 mm) flow, the voltage imbalance between the two chambers Is pro- 1 1 t 1 mm) .-- portional to the smoke density. When the voltage differences W N. ON SOUARE OR become great enough It causes the detector to go into alarm. OUTLET eox The two-chamber design is utilized to compensate for i changes in atmospheric and environmental conditions. ` t. `1<3. � 5 4 IN. t.!--.1 � (t48 mm C04211s I-- gawk. 3.17 05/21/01 MON 14:08 FAX 715 732 3479 TSS 2)004 ANSUL® Detection.and. Control Components aaiva■ sum"! stie ru a, 2 l i di sa win SLR -24 Photoelectric Smoke Detector Features " DIMENSIONS – NS6 -224 BASE 1 7/81N. • Low profile, 1.8 In. (46 mm) high – with base TO 4 IN. SQUARE OR 7/16 IN. (47 mm( IN. OCTAGON • 2 or 4 wire base compatibility, relay bases available 4 eox (11 mm) -i- • Highly stable operation, RFtTransient protection : � . 1 • Low standby current, 45pA at 24 VDC iklab-airt, i =. 6 „�,N. • Two built -In power /sensitivity supervision/alarm LEDs ° 0 (( 49 m ) • Non - directional smoke chamber • 1 + • Vandal resistant security locking feature • O _ ,•,,,,, • Built -in magnetic go/no go detector test feature • Removable smoke labyrinth for cleaning or replacement DIMENSIONS – NS4224 BASE (7/9 IN. • Automatic Sensitivity window verification function meets (47 fn"') outlined requirements In NFPA 72, Chapter 7, Inspection, ro 9 IN, 5/16 IN. Testing and Maintenance OCTAGON (6 nun) OUTLET BOX • Compatible with SIJ -24 Ionization detectors • Backwards compatible with SLK and SIH detectors �1::. - " a 1sn6 (N. [i Applications c4-` (+OOmm) The SLR -24 Photoelectric Smoke Detectors are Intended for "'~T • •mil. use in commercial, industrial, and institutional buildings. The i detectors are placed primarily in clean, Indoor environments — . ••«i• ••'•" • where early waming fire detection Is required. The detectors are used in combination with an Ansul DIMENSIONS – HSB-21 BASE AUTOPULSE® Control System and an Ansul fire suppres- 1 15/16 IN sion system for automatic detection, alarm, equipment con- TO 4 w SQUARE OUTLET eOX 9/16 IN. � (49 mm) trol, and fire suppression system release capabilities. (14 mrn) Description , The SLR -24 photoelectric smoke detector utilizes two bicolor , 7/8 IN LEDs for indication of status. In a normal standby condition lT . I,+ a� ( 149 ^•^) the LEDs flash Green every 3 seconds. When the detector / senses that its sensitivity has drifted outside the UL listed �� ' sensitivity window the LEDs will flash Red every 3 seconds. 0 When the detector senses smoke and goes into alarm the TO 3 OR 4 114. COMM — `°"" status LEDs will latch on Red. OCTAGON =LET 130X The detector utilizes an infrared LED light source and silicon DIMENSIONS – HSC-224RA BASE photo diode receiving element In the smoke chamber. In a i 2 (/2 IN. normal standby condition, the receiving element receives no 1 1/8 IN. (63 mm) (29 mm) —4. r-- light from the pulsing LED light source. In the event of a fire, m 4Ir. SQUARE OR r NC smoke enters the detector smoke chamber and light is 4 ET reflected from the smoke particles to the receiving element The light received is converted into an electronic signal. /f Signals are processed and compared to a reference level, or L dela and when two consecutive signals exceeding the reference I � -i (149') level are received within a specified period of time, the time i y circuit triggers the SCR switch to activate the alarm - -- - V, signal. The status LEDs light continuously during the alarm Weis , ,,.,, period. 3 -18 ANSUL® Detection and Control Components ( AO©PUIse Strobe 15 and 75 Candela Features STROBE WITH DIMENSIONS • Complies with Americans with Disabilities Act (ADA) 4 IN. 3IN. • 15 and 75 candela light intensities F(102 mm) � (76 mm) • No measurable in -rush in excess of peak current 0 0 • Unique design for maximum visibility and reliability I • Mounts directly to standard 4 in. (102 mm) back box 4 IN. M1.1 • Surface or semi -flush mounting available (102 mm) Description 0 FIRE C The strobe is suitable for primary signaling in public mode for life safety applications and complies with the Americans with 23/4IN. J 1/4 IN. Disabilities Act (ADA) and the demanding requirements of the (70 mm) ~ (6.4 mm) UL 1971 Standard for the Hearing Impaired. Both 15 and 75 candela strobes are available to meet the Tight intensity requirements for the space being protected. MOUNTING WITH OPTIONAL SEMI -FLUSH PLATE The strobe is intended for wall mounting only to a 4 in. STANDARD (102 mm) square electrical back box. Semi -flush mounting BACK BOX is available with the addition of an MP -SF mounting plate. ... r / MP -SF The unique lens/reflector design maintains a consistent Tight PLATE ( dispersement pattern at 15 or 75 candela light intensities /' while flashing at the ADA minimum of 1 flash per second. SIGNAL Stand alone strobe versions incorporate "installer easy" fea- STROBE tures: plug -in terminal strip, wiring guide, and strip gauge. Screw terminations provide secure attachment for field wiring k / of up to 12 AWG wire size. I�� Technical Information l ®Q,j Input Terminals 18 to 12 AWG Size: 4 in. x 4 in. x 3 in. (102 mm x 102 mm x 76 mm) eft Weight: 5 oz. (141 g) Color Red Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) WIRING DIAGRAM Mounting — Surface: 4 in. x 4 in. x 1.5 in. (102 mm x 102 ' mm x 38 mm)standard back box (2.5 in (64 mm) recommended) Semi - flush: 4 in. x 4 in. x 1.5 in. (102 mm x 102 ii I IA i, mm x 38 mm) standard back box TO NEXT (2.5 in (64 mm) recommended) with DEVICE + I - FROM mounting plate (order separately) OR EOL - CONTROL + UNIT Voltage Range 20 — 30 VDC Current (15 Candela) Peak 180 mA— regulated 290 mA — FWR unfiltered F Inrush: 0 mA over peak Operating 75 mA — regulated r' 90 mA — FWR unfiltered Current (75 Candela) Peak 400 mA — regulated 370 mA —FWR unfiltered Inrush: 0 mA over peak Operating 170 mA — regulated 200 mA— FWR unfiltered 3 - 36 Technical Information (Continued) Listings and Approvals* STANDARD LIGHT DISTRIBUTION UL S5512 VERTICAL DISPERSION Factory Mutual Research Corporation (FMRC) ... 0X8A3.AY ZERO AXIS DEGREES California State Fire Marshal (CSFM) 7125 - 1209:154 0 MEA MEA53 -94 -E 'Listings and Approvals are under System Sensor A 10 15 Ordering Information 20 Shipping Weight 90 85 807570 65 6055 50 45 40 35 30 25 Part No. Model Description Ib. (kg) FLOOR DEGREE PERCENT OF RATING 415453 SS2415ADA Strobe, 15 Candela 2 (0.9) 0 100 415454 SS2475ADA Strobe, 75 Candela 2 (0.9) 5 -30 90 35 65 415455 MP -SF Semi -flush Plate, 0.5 (0.2) 40 46 45 34 Composite 50 27 55 22 ANSUL and AUTOPULSE are registered trademarks. 60 18 65 16 70 15 75 13 80 12 85 12 90 12 HORIZONTAL DISPERSION 0° 45° -45° ip IGHT 90° -90° WALL DEGREE PERCENT OF RATING 0 100 5 -25 90 30-45 75 50 55 55 45 60 40 65 35 70 35 75 30 80 30 85 25 90 25 f- ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143 -2542 715 - 735-7411 Form No. F- 95113 -1 ©1996 Ansul Incorporated Litho in U.S.A. ANSUL® Detection and Control Components A utoPu I se J Electronic Sounder with Strobe Description DIMENSIONS The electronic sounder with strobe provides either indepen- _ IN 5 3/32 IN dent or simultaneous audible and visual alarm indication. I (102 m _� I (129 mm, ' The electronic sounder is UL listed for primary or secondary c signaling and the strobe is suitable for primary signaling in 1 public mode for life safety applications. OIN. The strobe complies with the Americans with Disabilities Act (102mm) III (ADA) and the demanding requirements of the UL 1971 _____ Standard for the Hearing Impaired. Both 15 and 75 candela 1 c FIRE 0 strobes are available to meet the light intensity requirements for the space being protected. _ 3314IN y (95 mm) One of eight different warning tones can be selected during 1 11/32 IN (34 mm installation by arranging three programming jumpers. The removed jumpers can be conveniently stored on the sounder for future tone program changes. The electronic sounder/ MOUNTING WITH OPTIONAL SEMI -FLUSH PLATE strobe mounts directly to a 4 in. (102 mm) square back box STANDARD with an optional semi -flush plate. BACK BOX Screw terminations provide secure attachment for field wiring MP.SF of up to 12 AWG wire size. ' / MOUNTING ✓ PLATE Technical Information ELECTRONIC Input Terminals: 18 to 12 AWG ®ID SOUND WITH STROBE Size:. 4 in. x 4 in. x 5 3/32 in. (102 mm x 102 mm x 129 mm) 011r0 1 Weight 10.4 oz. (293 g) Color Red O 1 111 6 „,, ,co perating Temperature 32 °F to 120 °F (0 °C to 49 °C) Mounting — Surface' 4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard back box Semi - flush: 4 in. x 4 in. x 1.5 in. (102 mm x 102 mm x 38 mm) standard TONE SELECTION TABS back box with MP -SF mounting 1 plate (order separately) ``� _ Voltage Range* 20 — 30 VDC " �- - Strobe Current (15 Candela) It ,� l L .. C 1� • : 08.1.-.4.....A. i08.1.-.4.....A. . � Peak 180 mA — regulated I ' A 8 290 mA — FWR unfiltered Inrush: 0 mA over peak . Operating: 75 mA— regulated CLIP STORAGE 90 mA — FWR unfiltered Strobe Current (75 Candela) Peak• 400 mA— regulated 370 mA — FWR unfiltered Inrush: 0 mA over peak • Operating: 170 mA — regulated 200 mA— FWR unfiltered Sounder Current: ... Dependent on tone selected, see chart • 3-38 Technical Information (Continued) SOUNDER CURRENT AND OUTPUT FOR 24 VDC r Program Sounder Current Sounder Output Tone Jumper (on) Regulated FWR Unfiltered Peak Rev. Room Slow Whoop ABC 34 81 92 85 800 Continuous' BC 36 77 93 85 800/1000 Alternating AC 31 75 92 85 2400 Interrupted AB 47 90 90 85 2400 Continuous C 47 90 94 85 1200 Interrupted B 29 62 91 82 Swept Frequency A 31 80 92 85 Fast Warble NONE 36 77 92 85 1 Tone factory set for 800 Continuous. 2 Peak sound output measured at 10 feet in an anechoic chamber; Rev. Room sound output measured in a UL reverberant room. 3 Add strobe current for total value. STANDARD LIGHT DISTRIBUTION INDEPENDENT OPERATION WIRING VERTICAL DISPERSION TO NEXT + — STROBE ZERO AXIS DEGROEES DEVICE OR , I� ■.I + SOUNDER w 5 _"1,"___ '\%. A t0 ��� 1 - L 1$ L 20 25 STROBE STROBE 90 85 80 75 70 65 60 55 50 45 40 35 30 FLOOR SOUNDER SOUNDER DEGREE PERCENT OF RATING COMBINATION OPERATION WIRING 0 100 5.30 90 TO NEXT — FROM 35 65 DEVICE OR + CONTROL 40 46 EOL n, a UNIT 45 34 50 27 MIr•��r•MIr• 55 22 60 1 65 6 Ft l �io1'' 16 70 15 75 13 80 12 85 12 90 t Listings and Approvals* UL S4011 HORIZONTAL DISPERSION Factory Mutual Research Corporation (FMRC) ... 0X8A3.AY 0• California State Fire Marshal (CSFM) 7125- 1209:154 es• -45' MEA MEA53 -94 -E 'Listings and Approvals are under System Sensor Ordering Information LIGHT Shipping 90• WALL -90• Weight DEGREE PERCENT OF RATING Part No. Model Description Ib. (kg) s 25 100 415450 MASS2415ADA Sounder /15 2 (0.9) 30.45. 75 Candela Strobe 50 55 55 45 415451 MASS2475ADA Sounder/75 2 (0.9) 65 35 Candela Strobe 70 35 75 30 30 415455 MP -SF Semi -Flush Plate, 0.5 (0.2) 85 25 Composite 90 25 ANSUL and AUTOPULSE are registered trademarks. ANSUL INCORPORATED. ONE STANTON STREET. MARINETTE. WI 541432542 715.735.7411 Form No. F.95115 -1 ©1996 Ansul Incorporated Litho in U S.A AIVSUL® Detection and Control Components A J Alarm Bell — 6 or 10 Inch Features 6 INCH BELL • High sound output with low current draw 6 IN. (152 mm) • Low frequency aluminum shells for better audibility through walls, doors, and other structures • Integral RFI suppression to minimize induced noise on the alarm circuit Q 3 3/8 IN. • Mounting options for surface, semi - flush, outdoor, and con- (86 mm) cealed conduit installation ; - - -� • Built -in trimplate makes semi -flush mounting simpler and less expensive 3 3/8 IN. • Screw terminals permit fast in -out field wiring of (86mm)y 22 -12 AWG wire } • Polarized for DC supervision of alarm circuit 2 3/4 IN. (70 mm) • Operate on filtered or unfiltered DC Description Ansul alarm bells may be used to alert the occupant before 10 INCH BELL IN. • and/or during actuation of the Ansul automatic fire suppres- 10 sion system and/or a general fire alert. (254 a mm) The Ansul motor driven alarm bell is designed to meet the special requirements of fire alarm /release systems where low power consumption and high sound output is essential. Due to its low current drain, high level output sound can be achieved with multiple units on a single 2 -wire output circuit. The bells are constructed of high quality materials to ensure -� reliability and long life. The basic mechanism, gong and accessories have a baked, red enamel finish. Holes are I I I 33/8 IN. located to mount to a standard 4 in. (102 mm) square outlet (86 mm) box. A weatherproof back box is available for outdoor use. 4. Technical Information -- —� Input Terminals 22 to 12 AWG 3 3/81N. ~ (86 mm) Bell Sizes 6 in. (152 mm) and 10 in. (254 mm) t -^ Voltage Rating 18 - 31 VDC 2 3/4 IN. (70 mm) Current Draw: 30 mA 4 Decibel Level: 92 dBA @ 10 ft. (3048 mm) Operating Temperature:.. -31 °F to 150 °F ( -35 °C to 66 °C) 95% humidity (when used with WIRING FOR BELL WBB, weatherproof back box) TO NEXT 0 0 FROM DEVICE + + CONTROL • OR EOL — — UNIT Listings and Approvals UL E71424 • ULC ML338 Factory Mutual Research Corporation (FMRC). OV1A5.KY California State Fire Marshal (CSFM) 7135 - 0595:110 Ordering Information Shipping Weight Part No. Description Ib. (kg) 417805 Alarm Bell, 24 VDC, 6 in. (152 mm) 7 (3.2) 417806 Alarm Bell, 24 VDC, 10 in. (254 mm) 9 (4.1) 24747 WBB, Surface Mount Back Box, 2 (0.9) Weatherproof ANSUL and AUTOPULSE are registered trademarks. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143 -2542 715- 735 -7411 Form No. F -95116 ©1995 Ansul Incorporated Litho in U.S.A. 05/21/01 MON 14:10 FAX 715 732 3479 TS 008 • ANSUL® Detection. and Control Components A , , it ..e ., toy P:..4 E lectrc Manual Pull r S v , • Features STANDARD PULL STATION • UL Listed/FM Approved • ' A'" \›` • Approved for ADA • Dual action FIA • Die -cast metal construction A `�f,I FIR ./ • Terminal block rii 411/18 IN • Optional auxiliary contacts n19 /NM • Flush mounts on single gang box _ • Surface mount back box available 1` • Weatherproof back box available • High-gloss red enamel finish • Customized labels 31/4IN. !83 na1) • Keyed to match AUTOPULSE control units awn Applications The Electric Manual Pull Station is a cost - effective, feature- WEATHERPROOF PULL STATION packed, non -coded manual fire alarm pull station. It was designed to meet multiple applications with the installer and , end -user in mind. • The pull station provides •the AUTOPULSE 442R, Egito AUTOPULSE 442D, AUTOPULSE I0 -301 and AUTOPULSE IQ -396X with an alarm initiating Input signal. 14E Its innovative desgn, durable construction, and multiple mounting options make the pull station simple to install, maintain, and operate. '11 1 : 4 11/161N. TILL I (1/o mm) Description The Electric Manual Pull Station is a high quality, die -cast ,' ,� metal dual action fire alarm pull station available with a SPST, DPST or DPDT switch, with terminal strip connec- � dons. The contacts are rated for 1 Amp at 30 VDC. Gold plat- _ �a 31/41N. ing on the contacts avoid the risk of corrosion. AU models in Oa a, ...,>0......./ .....<" 03 m"� the series have been tested by UL for compliance to the lat- est requirements of the American with Disabilities Act (ADA). The Electric Manual Pull Station is operated by pushing in °°K'r t the top bar and pulling the handle on the front of the station . as far down as it will go; at which point the handle locks into place and Is easily visible from up to 50 feet. Opening the station with the key, placing the handle in the normal upright position and re- locking the station resets the pull station. The addressable ready pull station comes with a bracket on the back for securing the FMM -101 Mini Monitor Module. The terminal block provides clamping plates for easy con- nection to the SLC loop and N. 0. switch contacts. An end - of -line resistor for the AUTOPULSE 10 -301 and AUTOPULSE 10 -396X is factory installed across the switch contacts. 3 -32 05/21/01 MON 14:10 FAX 715 732 3479 TSS 0 009 • Z r . WIRING - SPST PULL STATION !� . ►. li- 1 A114 I I I , ; . r 1; 1 1 • =� -f 1.. . I • f .. I =1 _ VIM' _ • TO /UlTOPUL.SE TO NEXT EOIR • CONTROL UNIT DEVICE • ao..: • C041102 TECHNICAL INFORMATION WIRING - DPST PULL STATION ConvantionaVAddresaable Ready Switch Ratings: 1 A 0 30 VDC 1 A 0 120 VAC Switch Type: SPST or DPST Terminal Size' Up to 14 AWG Color Red with raised white letters, white PUSH/PULL HANDLES with raised red letters • Weather Proof with Weather Proof Back Box NEMA 3R HHHH u 1 Hf Switch Ratings 1 A 0 30 VDC, 3C V� — EDLR 10 A 0 120 VAC Switch Type: . DPDT CONTROL wet DENACE Terminal Size: Up to 14 AWG °o..a, Humidity 90% Relative at 100 •F (37.7 °F) Explosion Hazard Classifications' Class t Groups B, C, D; WIRING - EXPLOSION PROOF PULL STATION Class 11 Groups E. F, G; Gass 111 r r Weatherproof Classifications' NEMA Type 4X Other Classifications: UL Marine Listing HHH HHH Conduit Fittings: 2 IL IL Conduit Fitting Size: 3/4 in. - 14 NPT Color Red with raised white letters, white PUSH/PULL handles with raised red letters ir USTINGS AND APPROVALS* HHH UL E 192508 '! — _ — - I. — A ULC wed 1 1 Factory Mutual Research Corporation (FMRC) Listed ° TO AUTOPULBE TO NEXT EOLA CCNTROLUNrT DEVICE California State Fire Marshal (CSFM) • 7150-1408:107 , coup MEA 382 -94 -E ORDERING INFORMATION WIRING - ADDRESSABLE READY PULL STATION Shipping - M -to, Weight • Part No, Description Ifs. fk91 RACK 428655 Manual Pull Station, SPST 1 ( ' 428656 Manual Pull Station, DPST 1 (0.45) I RED V10lET J 428657 Explosion Proof Manual Pull Station 1 (0.45) 428658 Manual Pull Station, Addressable Ready 1 (0.45) 428659 Weatherproof Back Box 1 (0.45) yEUCw 428660 Surface Back Box 1 (0.45) 4.-- _ EOLR 428661 Break Rod 1 (0.45) to �UL .• 6 ►*. OP SE . tt 418336 Key 1 (0.45) cc'rROLtiter — 428654 Label Packet 1 (0.45) • UMa and Among. we under loyal Csnwraralw. Corpontoo C04101 ANSUL and AUTOPULSE an r.gM.r.d tnwarnalMa. gNSUI tuCOFtPORATEO ONE STANTON STREET, MARTETTE, WI 54143 - 2542 715 0200% maul Incorporated OM in U.S A. • PULL TO ACTUATE FIRE SUPPRESSION SYSTEM • • - • - • - • "- • pa., N., ANSUL® Detection and Control Components c Aut) P u l s Key Maintenance Switch Features TYPICAL WIRING DIAGRAM • Stackable, screw - terminal, contact blocks KEY - OPERATED CONTROL UNIT LOCK -OUT SWITCH RELEASE CIRCUIT • Compatible with AUTOPULSEe control units ACTUATOR r 7 TERMINALS' — — — – • Surface -mount assemblies listed by Ur•,lerwriters I MOE I Laboratories, Inc. '' ( ) • Components mounted on stainless steel switch plate I N O I I ( +) I Applications I A 1 POLARITY IS The Key Maintenance Switch is used to interrupt the release 1 '• q i IN ALARM circuit signal to the fire suppression system. It is ke -o erat- I_ _ — _ _ 1 24 VDC POWE I CONDITION S PP Y Y P SOURCE ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, 24 VDC located on the switch plate, will light when the switch is in the INDICATOR LAMP "lock -out" mode to serve as a reminder that the release cir- • SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. cuit has been disconnected. Description Ordering Information The Key Maintenance Switch assembly consists of a key- Shipping operated switch, 24 VDC indicator lamp, normally -open con- • Weight i, tact block, normally- closed contact block, and stainless steel Part No. Description Ib. (kg) switch plate with silk- screened label. Surface -mount assem- blies include a double -gang weather -proof box with three 1/2 , 76498 Maintenance Switch, Surface -Mount 2.0 (0.9) in. I.P.S. threaded conduit outlets and gasket. 76499 Maintenance Switch, Flush -Mount 2.0 (0.9) The stackable, screw - terminal contact blocks are rated for 28 76485 Extra Contact Block, N.C. 0.25 (0.11) VDC @ 1.1 amp make/break or 6 amp continuous carry. 76486 Extra Contact Block, N.O. 0.25 (0.11) Listings and Approvals • 78179 Spare Key . 0.25 (0.11) The switch is UL listed (S3623) when installed in the surface - mount box (with gasket) that is provided with the surface- ANSUL and AUTOPULSE are registered trademarks. mount assembly. MOUNTING DIMENSIONS • SURFACE -MOUNT FLUSH -MOUNT 4 11/16 IN. 3 1/8 IN. 2 3/4 IN. ~ (119 mm) ` —� I I — (79 mm) ~ — (70 mm) —y 0 0 NORMAL LOCK -OUT 4 O ip 45/8 IN. II (117 mm) _ I ANSUL FIRE SUPPRESSION SYSTEM ABORT ( :' 0 0 / 3 -33 ANSUL INCORPORATED. ONE STANTON SI Fitt i .MARINtI it. WI54143.2542 715 - 735.7411 Form No. F-95110 ©1995 Ansul Incorporated Litho in U.S.A. ANSUL® Detection and Control Components AjlPuIse Abort Switch Features TYPICAL WIRING DIAGRAMS • Stackable, screw - terminal, contact blocks ABORT SWITCH (SERIES) • Compatible with AUTOPULSE® control units EOL RESISTOR r • Surface -mount assemblies listed by Underwriters Laboratories, Inc. I 0 ( +) • Components mounted on stainless steel switch plate ; - -1 (-) I CONTROL UNIT Applications N.C. ABORT I ABORT CIRCUIT [TERMINALS' The Abort Switch is used to momentarily interrupt the release SWITCH circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- ABORT SWITCH (PARALLEL) sion system will not release. (Note: When the control unit is r --- — programmed for IRI compliance, the abort will not be effec- EOLRESISTOR 1 tive after pre - discharge.) When the pushbutton is released, ,, (,) the release circuit is activated (unless the control unit has ) l been reset to the non -alarm condition). 1 t I %(a Description '---_— L.____—J I CONTROL UNIT N.O. ABORT S WITCH ABORT CIRCUIT The Abort Switch assembly consists of a momentary - 'TERMINALS' contact pushbutton switch, normally -open contact block, • SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. normally- closed contact block, and stainless steel switch , plate with silk- screened label. Surface -mount assemblies Ordering Information include a single -gang weather -proof box with three 1/2 in. Shipping I.P.S. threaded conduit outlets and gasket. Weight The stackable, screw - terminal contact blocks are rated for 28 Part No. Description Ib. (kg) VDC @ 1.1 amp make/break or 6 amp continuous carry. 76494 Abort Switch, Surface -Mount 1.0 (0.45) Listings and Approvals 76495 Abort Switch, Flush -Mount 1.0 (0.45) The switch is UL listed (S3623) when installed in the surface- 76485 Extra Contact Block, N.C. 0.25 (0.11) mount box (with gasket) that is provided with the surface- 76486 Extra Contact Block, N.O. 0.25 (0.11) mount assembly. ANSUL and AUTOPULSE are registered trademarks. MOUNTING DIMENSIONS SURFACE -MOUNT FLUSH -MOUNT 2 7/8 IN. �_2 5/8 IN. ---." +_ 2 3/8 IN. _► (73 mm) I (67 mm) (60 mm) N t 0 ANSUL FIRE SUPPRESSION SYSTEM ABORT Illit O I ; I 4 5/8 IN. i (117 mm) IB ( PUSH AND HOLD — J 0 3-34