Permit . - q .' ------ CITY OF TIGARD • IIII MECHANICAL PERMIT r COMMUNITY DEVELOPMENT PERMIT #: MEC2008 - 00252 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 DATE ISSUED: 5/22/2008 PARCEL: 2S 102CC -00500 SITE ADDRESS: 13600 SW PACIFIC HWY ZONING: C -G SUBDIVISION: TIGARD MARKETPLACE LOT: JURISDICTION: TIG PROJECT: H MART Project Description: Intalling (2) hood systems. Valuation: $18,000. CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: M VENTS W/O APPL: VENT SYSTEMS: STORIES: 1 BOILERS /COMPRESSORS HOODS: 2 FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Owner: FEES 13500 PACIFIC CORP Description Date Amount BY CAP ADVISORS 38345 W TEN MILE RD, STE 170 [MECH] Permit Fee 5/22/200€ $339.50 FARMINGTON HILLS, MI 48335 [MECPLN] Plan Rev 5/22/200E $84.88 [TAX] 12% State Surch 5/22/200€ $40.74 Phone: Total $465.12 Contractor: A -1 STAINLESS STEEL FABCO. BOX OR EGON CITY, OR 97045 R QUIRED IT f' AND REPORTS OR ,/ a Contact #: PRI 503 - 631 -8896 FAX NA Reg #: LIC 165278 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952-0010100. You may obtain copies of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued B l� // - --rmittee Signature: / . hat Call 50175 by 7:00 a.m. for inspection- at busin-ss • -y. This permit card shall be kept in a conspicuous place on the job site until completion of the project. . Approved plans are required on the job site at the time of each inspection. iikAN .1 k J (CJC '9-) - , NcAF1 r -: .� ti a Sf a - s r r t• ; + Mechanical Permit Application ` ' FoliioH f I isto�'�"4 1`. . "ya .ani ,... , x •'4,1 tfi�'ltA 11 C of Tigard * 1 . , Date/B • Received rmit No.: a ' 3125 SW Hall Blvd., Tigard, OR 972 t� 1 i Plan Revi ' � a e . Phone: 503.639.4171 Fax: 5o3.598.1 'r Date/By: „ALP l � / `' Other Per "�( ' Ins ection Line: 503.639.4175 ^ * y AL . / '� " T I G A(RD p Q (.O Date Ready ty: - = See Page 2 for - ti Internet: www.tigard or.gov \ Notified/Method: A/ -uJ/ Supplemental Information G ��,��-_ �� ta l TYPE OF WORt, Q� CO MERCIAL FEE * SCHEDULE - USE CHECKLIST ❑ New construction A Addition /alterati00acement Mechanical permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. CATEGORY OF CONSTRUCTION . Value: $ 1�j 000 °— • RESIDENTIAL EQUIPMENT /SYSTEMS FEES* ❑ 1- and 2- family dwelling OCommercial/industrial ❑ Accessory building , ❑ Multi- family 0 Master builder For special information use checklist. 0 Description 1 Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling 3rOo S (U Air conditioning or heat pump Job site address: t 4�l�� P (requires site plan showing placement) 14.00 City /State /ZIP: 'fl A 2 fl Furnace 100,000 BTU (ducts /vents) 14.00 !-T��1 (7)/2_. � J A' AKA-- Furnace 100,000+ BTU (ducts /vents) 17.90 14 Suite/bldg. /apt. no.: I Project name: — 1 Gas heat pump 14.00 Cross street/directions to job site: Duct work 10.00 Hydronic hot water system 14.00 Residential boiler (radiator or hydronic) 14.00 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 14.00 Subdivision: i Lot no.: Flue /vent for any of above 6.80 Other: 10.00 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 10.00 Gas fireplace 10.00 2 EA T4 PG -I. L + E= 5 at, 0 0 sLesirc Flue vent for water heater or gas fireplace 10.00 Log lighter (gas) 10.00 Wood/pellet stove 10.00 Wood fireplace /insert 10.00 ❑ PROPERTY OWNER I . ❑ TENANT Chimney /liner /flue /vent 10.00 Other: 10.00 Name: Environmental exhaust and ventilation Range hood/other kitchen Address: equipment 10.00 City /State /ZIP: Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 6.80 ❑ APPLICANT . . • ❑ CONTACT PERSON Attic /crawlspace fans 10.00 Business name: Other: 10.00 Fuel piping Contact name: $5.40 for first four; $1.00 for each additiona Address: Furnace, etc. Gas heat pump City /State /ZIP: Wall /suspended/unit heater Phone: ( ) Fax:: ( ) Water heater Fireplace E -mail: Range CONTRACTOR Barbecue ` Business name: 4_ L t. S PA -0A i. i`-1rL Clothes dryer (gas) Other: Address: 7 t 0 ` k 6 MECHANICAL PERMIT FEES* City /State /ZIP: ` © er,. / C__ 1 ®/ �� S Subtotal Phone: (?) _ �3 j 9S� ! Fax: ( ) Minimum permit fee ($72.50) Plan review (25% of permit fee) CCB lic.: t V 52-75 State surcharge (12% of permit fee) TOTAL PERMIT FEE Authorized signature: This permit application expires if a permit is not obtained within 180 A444 AA', days after it has been accepted as complete. Print name: 6 �j 3, -� c Date: 20 A44 A • Fee methodology set by Tn- County Building Industry Service Board 1 \ Building \Permits\MEC- PermitApp.doc 01/19/07 440 -4617T ( „ 11/02 V 2 /COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information . Commercial Fee Schedule: • Total Valuation: Permit Fee: • $1.00 to $2,000.00 Minimum fee $72.50 $2,001.00 to $5,000.00 $72.50 for the first $2,000.00 and $2.30 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,001.00 to $10,000.00 $141.50 for the first $5,000.00 and $1.80 for each additional $100.00 or fraction thereof, to and including _ $10,000.00. $10,001.00 to $50,000.00 $231.50 for the first $10,000.00 and $1.35 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 to $100,000.00 $771.50 for the first $50,000.00 and $1.25 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,000.01 and up $1,396.50 for the first $100,000.00 and $1.10 for each additional $100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I: \Building\Permits\MEC- PermitApp.doc 01/19/07 2 CITY OF TIGARD . BUILDING DIVISION PERMIT #: MEC2000.00252 13125 SW Hall Blvd., Tigard, OR 97223 r DATE ISSUED: 5/2212000 Phone: (503) 639 -4171 I ° , j' Inspection Requests (24 Hrs.): (503) 639 -4175 1� - '� i.. INSPECTION WORKSHEET FOR DATE: 6/4/2008 TIME: 7:01AM PAGE: 19 SITE ADDRESS: 13600 SW PACIFIC H1NY CLASS OF WORK: SUBDIVISION: TIGARD MARKETPLACE LOT #: TYPE OF USE: PROJECT NAME: 11 MART DESCRIPTION: Intalling (2) hood systems. Valuation: $18,000. OWNER: 13500 PACIFIC CORP, PHONE #: CONTRACTOR: A - STAINLESS STEEL FABCO. PHONE #: 503- 631 -8896 Inspection Request Scheduled For: Date: 6/4/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 610 Exhaust hood 070840.01 503. 631 -8896 N Corrections /Comments /Instructions: ThL)S ( 1 — c.JS i -2 v t. pj c -Zth CZ:> cam Rc=�P 1 - 1 j2 &-Th / - 1(z C c—` NI f '- _ _ M 0 • - m • Ste- v V • .---- t r ] fr ❑ PASS a PARTIAL APPROVAL 111 CANCEL ❑ NO ACCESS 74 a. CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 442-- 6 Phone #: (503) 718- CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2008 -00252 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 5122/200/1 Phone: (503) 639 -4171 ido t � Inspection Requests (24 Hrs.): (503) 639 -4175 °I I.. INSPECTION WORKSHEET FOR DATE: 5/23/2008 TIME: 7:00AM PAGE: 6 • SITE ADDRESS: 13600 SW PACIFIC HWY CLASS OF WORK: SUBDIVISION: TIGARD MARKETPLACE LOT #: TYPE OF USE: PROJECT NAME: Fl MART DESCRIPTION: InW:alling (2) hood systems. Valuation: $163,000. OWNER: 13500 PACIFIC CORP, PHONE #: CONTRACTOR: A -1 STAINLESS STEEL FABCO. PHONE #: 503 631 - 8896 Inspection Request Scheduled For: Date: 5123/2006 Pour Time: Code # Inspection Description Confirm # Contact # Messa• - 640 Exhaust hood 070331 -01 503- 631 -8896 CV 1!3° o Corrections /Comments /Instructions: f a ° CO r l _ 1 ./ • -\ n PASS /2 PARTIA • APP' • , ❑ CANCEL ❑ NO ACCESS n FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED r L Inspector: _ - Date: �= V Phone #: (503) 718 - L�