Permit C ITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2006 -00371 JIB' DEVELOPMENT SERVICES DATE ISSUED: 8/14/2006 ----- -- 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 1 S 126C0 -01403 SITE ADDRESS: 09483 SW WASHINGTON SQUARE RD ZONING: C - G SUBDIVISION: LOT: JURISDICTION: TIG Project Description: Fire system upgrade • REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: OCCUPANCY GRP: A3 TOTAL AREA: 0 sf ROOF CONST: A FIRE RET? OCCUPANCY LOAD: 174 BASEMENT: sf AREA SEP. RATED: STOR: 1 HT: 30 ft GARAGE: sf OCCU SEP. RATED: BSMT ?: N MEZZ ?: Y READ SETBACKS REQUIRED FLOOR LOAD: 50 psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:y DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:y BEDRMS: BATHS: IMP SURFACE: PRO CORR: Y PARKING: VALUE: $ 5,839.00 ' Owner: Contractor: MAY DEPT STORES COMPANY, THE LAING INVESTMENTS,INC. ATTN: PROPERTY TAX DEPT 3357 SE 21ST AVE 611 OLIVE STREET DBA: NATIONAL FIRE FIGHTER ST LOUIS, MO 63101 PORTLAND, OR 97202 Phone: Contact #: FAX 503 - 232 - 7198 PRI 503 - 323 -6646 Reg #: LIC 143295 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 8/3/2006 $100.90 [TAX] 8% State Surcha 8/3/2006 $8.07 , [FLS] FLS Pin Rv 8/3/2006 $40.36 Total $149.33 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. Issued By: Permittee Signature: d`'y a / ' t . 1 - G - Call 503 - 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. / C�' �€ / k Fire Protect.on ys (/f/�s �� �� • • ..-- �� "' w. '�'i ti n.Ti` Y�" s. fi�° kM:2� « �,`�"" ��r �` -n,„, t : war.,` Building Permit Applicati t 1 a► r rM,. .�. „�,,��'� 1 012'01 I IC 1 ?Util }�0\'I ltr, ti"'`�"""`V y�l'?r� �'' r� 0#4.1 tom 3< < ,- KrUgLd k c eT ra e i "_ '-wlvs Rc i Cl of Tigard a . .:N . r a:.. t ` EC ��IJ}'/ Received / Pertmt No.: � 11 Phone: 503.639.4171 Fax: 503.59811 ¢ `" v 13125 SW Hall Blvd., Tigard, OR 97223 cc`` Plan Revie�j�/ /� 9 7 D , 2 Date Ready :y: Other Permit: ; Inspection Line: 503.639.4175 2006 ®See Page 2 for 7.T I C A I. I) p CI DU Notified/Method: Su lemental Information *'__ =' ++� =�1e Internet: www.tigard or.gov TY op PP B UILDING D I u ARD ' TYPE OF WORK N ' REQUIRED DATA: -1= AND 2- FAMILY DWELLING •. ❑ New construction ❑ Demolition Permit fees' are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Addition /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the • CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling P3f Commercial /industrial Valuation: S ❑ Accessory building CI Multi-family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION' Total number of floors: Job site address: 914 B3 S W W Fk -} l TOkS 5ckvikoveR.D. New dwelling area: square feet City /State /ZIP: 7 RD, OZ. 97zZ3 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: M CbpN Covered porch area: square feet Cross street /directions to job site: N1 C Da NJ /{LDS RESTPt1RI* ky Deck area: square feet 1 IJ kD &SR i /.1C;Tz1J SQ U R Ra✓ kk14L1_ Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees' are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all / equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK ( s: S work indicated on this application. 1) L- 1 O U RFNDE EX t STt KA XNS° L Valuation: $ 5339 S Existing building area: 0 square feet Si/ w, TH n1Ew c�ti RoL CR61I�lETs, TAQ14-5� cr1EMI'CAL c 1 Al2TRtb�j>ES, ND C-ES New building area: square feet t ;_ ❑" PROPERTY OWNER - ❑ TENANT Number of stories: Name: Type of construction: 5 Address: Occupancy groups: is 04i City /State /ZIP: Existing: Phone: ( ) Fax: ( ) New: APPLICANT ' ONTAC• PERSON , , . • NTICE '. Business name: N AT i 0 IJA L Fi RE VIA HTEl2 L'oRf:. . All contractors and subcontractors are required to be Contact name: Rr - T licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 33S7 SE Z ( S I _ A V E , jurisdiction in which work is being performed. If the City /State /ZIP: pf p- L ? C �R , G') 2O Z applicant is exempt from licensing, the following reasons apply: J 00. i b 603) 708 -agog Fax: :(So3) 232 -7,98 $ .D 7 E -mail: ER / ` L' C' & A) Arh6/ 3f-L g Rai/ 'elN , a )4-4 i'o , / CONTRACTOR ` ' BUILDING PERMIT. FEES *, . Business name: N) A 1'i c A-f'_ p"-1 a E r r ii-T-&--/a Ce� (P►easerejertojeesrhedulel Permit fee: Address: L.. N I N I/ 1 ' State surcharge (8% of permit fee): City /State /ZIP: ° FLS plan review (40% of permit fee): Phone: ( ) � l?' t' Fax: ( ) (Due upon application) CCB lic.: 'J z9 5 .t.A, f INt1E5Ta?E/V1s Total permit fees: Authorized signature: j D8A - IV,Inimuin r 4 h7 �? �� Amount received: ,(lg 33 • " /] , "� This per i t application expires if a permit is not obtained Print name: ` ER, . t1Q p.. j Tr Date: 0/2/64, within 180 days after it has been accepted as complete. ' Fee methodology set by Tri- County Building Industry Service Board. 1: \Building\Per its\FPS- PermitApp.doc 03/23/06 440 .4613T(11 /02/COM/WEB) City of Tigard: Fire Protection Permit Checklist , Page 2 - Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only ❑ Addition ❑ 1 -10 heads: No plan review required. g Alteration ID 11+ heads: Plan review required. El Repair Number of sprinkler heads: Additional description of work: Type of System.: (Complete A, B, C or D as applicable): A.) Commercial Sprinkler El Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I Hood Fire Suppression System Hood Project Valuation: $ 5 g 39 C) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.)" Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ . Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (8% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. 1: \ Building \ Permits \ ITS-Permit App.doc 2 / /mitt r 4111‘ l l h August 14, 2006 = I, L .. ; CITY OF TIGARD OREGON National Fire Fighter Corp. Eric Canutt 3357 SE 21' Ave • Portland, OR 97202 RE: R -102 FIRE SUPPRESSION SYSTEM FOR TYPE ONE HOOD erect Information Building Permit BUP2006 -00371 Construction Type: 5 B . Tenant Name: McDonalds Occupancy Type: A3 Address: 9483 SW Washington Sq Rd. Occupant Load: 174 Area: 5,560 Sq Ft • The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), Mechanical Specialty Code (OMSC) 2004 edition and 2004 Oregon Fire Code (OFC) amended by Tualatin Valley Fire & Rescue. The submitted plans are approved subject to the following. 1. The automatic fire suppression system shall be of a type recognized for protection of commercial cooking appliance and exhaust systems of the type and arrangement protected. Pre - engineered automatic dry - and wet - chemical fire suppression system shall be tested in accordance with UL 300. Automatic fire suppression systems, including pre - engineered and engineered dry - and wet chemical fire- suppression systems, shall be listed and labeled for specific use as protection for commercial cooking operations and shall be installed in accordance with this code, its listing and manufacturer's installation instructions. OFC 904.11 -OMSC 509.2 2. The actuation of the automatic fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking appliances. The fuel and electrical power supply reset shall be manual. OFC 904.11.2 - OMSC 509.4 3. Each automatic fire suppression system shall have both automatic and manual actuation means. A manual actuation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual actuation device shall be located a minimum of 4 feet and a maximum of 5 feet above the floor. The manual actuation shall require a maximum force of 40 pounds and a maximum movement of 14 inches to actuate the fire suppression system. OSSC[F] 904.11 4. Automatic sprinkler systems protecting commercial -type cooking equipment shall be supplied from a separate, readily accessible, indicating -type control valve that is identified. OSSC [FJ904.11.4 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 5. Sprinklers used for the protection of fryers shall be listed for that application and installed in accordance with their listing. OSSC [FJ904.11.4.1 6. The automatic fire suppression system shall be acceptance - tested in accordance with OFC 904, and installation standard listed in section OMSC 509.3, and with the manufacturer's instructions. OMSC 509.5 7. The automatic fire suppression system shall be serviced at least every 6 months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. OFC 904.11.6.4 Premises Identtifcation: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittttal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henze!, Senior Plans Examiner y s zona F IRE FIGHTER CORP. flCCEII \/E t AUG 3 2006 CITY OF T IGA UL -3 00 Upgra t ° o N ex is ti n g " Ansul " Pre- engineered fixed fire suppression systems Installation at: Mcdonalds Restaurant 9483 SW Washington Square Rd. Tigard, Or. 97223 Installation Provided by: National Fire Fighter 3357 SE 21S Ave. Portland, OR 97202 JL 3p0 aryl ®, o c Condo . v , ) W . See Li' TTI CE CO Wildland Division: Service Division Locations: L a i n g. C o m p a fl I e s 1574 W 6th Ave 1574 W 6th Ave 3357 SE 21st Ave 594 S Broadway Eugene, OR 97402 Eugene, OR 97402 Portland, OR 97202 Coos Bay, OR 97420 lodu$trial Source ph 800.423.8347 ph 541.485.3566 ph 503.232.6646 ph 541.267.7049 Atie fax 800.891.1982 fax 541.302.6424 fax 503.232.7198 fax 541.269.5728 www.nationalfirefighter.com • Install Date: august `06 Laing Investments, °�' ��L� McDonalds, Washington Square dba - National Firefighter Corp. - 9483 SW Washington Square Rd. 3357 S.E. 21st Ave. Tigard, Or. 97223 Portland, Or. 97202 Eric Canutt Eric Canutt %03- 708 -6808 503 - 708 -6808 ericc @nationalfirefighter.com 2 vat fry hood Untitled Layout Duct 6 in. diameter 1 � - Plenu 37 -ii 1 ., in. 0 401 04. 1 .<1› / i lj." 0 ILO 1 1 F ry vat 14 x 15 in. With dripboard: 14 x 21 in. 1 Fry vat, 14 x1 S in. With dripboard: 14 x 21 in. Flow Summary: Coverage Overall Dimensions Nozzle Flows Nozzle Location Hood: Low - Profile 37 x 24 in. 1N 1 0-4 in. from filter face,center of height dimension, aimed down filter length. Duct: Round 6 x 0 in. 1W 1 2 -8 in. into center of duct opening, aimed up Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Total Flow Points 6 i page 2 of 5 .•', AkreSU L Install Date: august `06 Laing Investments, McDonalds, Washington Square dba - National Firefighter Corp. 9483 SW Washington Square Rd. 3357 S.E. 21st Ave. Tigard, Or. 97223 Portland, Or. 97202 Eric Canutt Eric Canutt %03- 708 -6808 503 - 708 -6808 ericc @nationalfirefighter.com Griddle hood Untitled Layout Duct 12x12 in. 1 iii 11 • enu 4141; in. 10 /4< Griddle platen 39 x 28 in. Flow Summary: Coverage j Overall Dimensions Nozzle Flows Nozzle Location Hood: Low - Profile 41 x 24 in. 1N 1 0-4 in. from filter face,center of height dimension, aimed down filter length. Duct: Square 12 x 12 in. 1W 1 2 -8 in. into center of duct opening, aimed up Griddle 40 x 28 in. 290 2 20 in. -30 in., 0 -2 in. inside perimeter, aimed at center Total Flow Points 4 page 14 of 18 1•®' IA ULn) Install Date: august `06 Laing Investments, McDonalds, Washington Square dba - National Firefighter Corp. 9483 SW Washington Square Rd. 3357 S.E. 21st Ave. Tigard, Or. 97223 Portland, Or. 97202 Eric Canutt Eric Canutt %03- 708 -6808 503- 708 -6808 ericc @nationalfirefighter.com ClamShell Griddle Hood Untitled Layout Duct 12 x 12 in. x18 in. , Griddle platen 36 x 24 in. Griddle platen 36 x 24 in. Flow Summary: Coverage j Overall Dimensions I Nozzle Flows Nozzle Location Hood: Low - Profile 84 x 24 in. 1N 1 0-4 in. from filter face,center of height dimension, aimed down filter length. Duct: Square 12 x 12 in. 1W 1 2 -8 in. into center of duct opening, aimed up Griddle 38 x 28 in. 290 2 20 in. -30 in., 0 -2 in. inside perimeter, aimed at center Griddle 38 x 28 in. 290 2 20 in. -30 in., 0 -2 in. inside perimeter, aimed at center Total Flow Points 6 page 11 of 18 M. ASUL Install Date: august `06 Laing Investments, McDonalds, Washington Square dba - National Firefighter Corp. 9483 SW Washington Square Rd. 3357 S.E. 21st Ave. Tigard, Or. 97223 Portland, Or. 97202 Eric Canutt Eric Canutt %03- 708 -6808 503 - 708 -6808 ericc @nationalfirefighter.com 3 vat fry hood,specialty Untitled Layout Duct 12x12in. • i t l.//1 Plenum //. X18 ; -, ' / ,,,,,aa , Ohk- /'7.0.......• • 4 0 4 Iti vi itit., ....-0 1 i Fry vat, 14 x 15 in. With dripboard: 14 x 21 in. 1 Fry vat, 14 x 15 in With dripboard: 14 x 21 in. 1 Fry vat, 14 x 15 in. With dripboard: 14 x 21 in. l Flow Summary: Coverage Overall Dimensions 1 Nozzle 1 Flows Nozzle Location Hood: Low -Profile 50 x 24 in. 1N 1 0-4 in. from filter face,center of height dimension, aimed down filter length. Duct: Square 12 x 12 in. 1W 1 2 -8 in. into center of duct opening, aimed up Fryer: Split vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Fryer: Split vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Total Flow Points 8 page 8 of 18 ®� Al SUL. Install Date: august `06 Laing Investments, McDonalds, Washington Square dba - National Firefighter Corp. 9483 SW Washington Square Rd. 3357 S.E. 21st Ave. Tigard, Or. 97223 Portland, Or. 97202 Eric Canutt Eric Canutt %03- 708 -6808 503 - 708 -6808 ericc @nationalfirefighter.com 3 vat fry hood, Fries Untitled Layout Duct 12 x 12 in. I Plenum (1 A Or 100 tFry vat, 14 x 15 in. With dripboard: 14 x 21 in. 1 Fry vat, 14 x in. With dripboard: 14 15 x 21 in. 1 Fry vat, 14 x 15 in. With dripboard: 14 x 21 in. Flow Summary: Coverage j Overall Dimensions Nozzle Flows Nozzle Location Hood: Low - Profile 50 x 24 in. 1N 1 0-4 in. from filter face,center of height dimension, aimed down filter length. Duct: Square 12 x 12 in. 1W 1 2 -8 in. into center of duct opening, aimed up Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Fryer: 1 vat, dripboard 16 x 24 in. 245 2 20 in. -27 in., along/within perimeter, aimed at center Total Flow Points 8 page 5 of 18 , ; `, _� DESIGN R -2 RESTAURANT INSTALLATION FIRE 10 SUPPRESSION RECHARGE AND SYSTEM MAINTENANCE (Standard UL 300 Listed) MANUAL i K w . � . k: ' .b i� tk 41 '$ :S g. ! r s t r �- �Yi 5' � t 7 � 4 n ► `✓a gir 5 ""r � t 9 dh M1�1 i � r !,.!,..,14'''.4.::11...c:-...:::.-1:'''!if.57.--;:,-7*t-,ii ��I -C - 4. 7 , . .1 j lb.. � • C -1s, r •�R w l• ' ,7 'w" ' � F: s { � r. at"ir� {^41',P4.-- f f`r' a iC k ^ n . n 1 7 yf, srnr a d✓ x i - 4 r;{. i t r e , Me TT f f `r tt h" k 1 t � F � `�, , y f 'r6' `►,, �jy �' 4, p '4G• f ` e?", � .�# y ; i r e. , ` , t'+ �, ��, 'k- fi� i ) h 17 •l� r r. T' , h � � ,,. jt' T* r y- M ; '' t k kC jx 3lt ! i � 6 ��, t ,p a n 1 r � i��.f tt � q ? ' r '4. {T'4' (Y 1 r le - - l •=7,1.0., �i %." td S f. '� x .� , . I f 1 ' 't + p k `„ i K • ,t . - r ' 4 •n 'u $ ' ..K u r a Nl P ^' 4 r i 1m ' 7 F' ,„ .,. a ? 1 - + � y .,?cdl. •y , `+1���c. iRGi; ..''V''-&''''' d # nv. s ar � Y} xl c c f i aR 1 4 a r T ,. M t .' 4 * G` ` t - K t eem d � I£4' w 43� t't .� 1 MCI » " ' . � a t T ° , yi w� �f +r"4 3h, ki V� A 'r r ` ri'3 At ' ; y44 rl y vChtiY i ` t y �� � Y - dZ • i + y kr e� r i r1 d , tt k F+ 4 4:-,214' .C>< 2 .i. t ,, �r't 2, e' r "? ` L''" A -' ' ' a '''' '' a , . h T , .' t ji . 4. Xfti - .► + ® , f jg"'.% 74 I t r +k r� e� r � .� ! A XI: ` Itrd 1 r r t tY ,, �, ii t (il 1 �{ -` , w v c� t 7 i ± 5 & . 3� 1,, � ! h '` r , { �-' � ' it "y ' ro T ''M`r *. Y 1� 'h y a 4 5 P `_} + ' " 33P. yp ,. 1 r{. ..,r til' f t ,r`t ^� +ra¢ .;- b s '*' xi 1,k _e M .2& r � /r4 �' .�., t y es+ , ,i. d It Yp t f r. p Tf i.� ?` r �ii�i'''itC 4�+oW �rs.w., illui ��r� FFn 4 ■ .r a 1 � . t'"�. T 1 G ' „ ' J y� "w iicxtl ?9 ?� ♦{ .Yr`r1 t "�h ! {t r- � q t y ". "rJ' '� '}' k ) _ er r ���� 5, a � t , ( � ] t. • Vi a i `tom' • ' 4 j ' r ' A� atf`+t'q '�'t a } � i = ,,, � L; ? ' ray S �' r t . A ` f,'9) t , ,y k ` 'A ® i ..rs ! 1 . '� s 0 h, r �eR , br.. 4a i T '�N+r ' i� /r 3 fa3 >. j ,1';' , y ` " �tE l ? i , !d r t�i ' ' it, t., � , . : ` , .fi x 4' L6 ,1 + P : . 44, 1 , ( / yq g r k. ! ! 77 x Cr � n0. --s� -it 4 .43'r , 3r 0.1. + ∎i I f, a .- d u a i4' gwdr,r t� n.' ' d! P x- } ` " R t. � i 11ap it , h-�s t ! 4 ,1 '� :'8;� h. , rI t w S'.o '‘,.""7,:;140,e f ;'"M ! h . 'l ''4 it ' j H"St6' i rt � r.-,q i I ; t." t7 C+ " C%1 I ✓ .,', ' t n 4N t.lp "�" x ; 1 � i tF j , �y t , k, h ` . .a 'Y� ��.$ "„ i,4 + " ' r r'4z+H' ,p r 7 {,` 1� i u +t xA j ra ✓ " '>• ,il'k . a t{ k ti` x i , � Y 1, s. ,,i '' t " f ik �. r i ; ' 14,6 .rr f 1,1iY 77, , t r�` �7 '* ' 3 ! r y ii • � 'fi` . ' , x 5 t ta I t'pF it'' 3 d r'rY: f ; 1 h r h t# -r # d 1 . ra c 4 - h'�", : .p r !' T s G l� f , tx! n r f�,t '� , '1 w� 1, 1 f#` ( R ' ' .. { t a *-. { ` {'i ' , 7 g g; r �� , � a X1 S P�f ^� �� I r i _ „tt�yff t i nt tl J+ h "57' � •' * .' � g �� `kJ rk ¢. p. F . 1 k rJ �''t yY,,'� } r"'"hl`. ■ i�+ fi a, y ,�'�a+s �, " .7h } r+ rt `,k ro� �4 f 1 40, i ; 4t lk ` ., �t 5 r fo i 5 5- 'f tR Fal >-'% q il : # L+ S`s � , J ' r. 3 ,, ��1 i+ tr i.. r &M r4.1.1-,>,;,/,, r a - �' ^ n ` . � F c ' ; � xL4 • � , 5r r J r�"�.�• r n_ x A _ ''Y'gr � i� ' �. 411, F,s r e tt . A Ifr * �{P � 1 x 1,1:1(14,-;.1,-14:•'.7. f' r'$ - 1 - I s "n 1A j F I � �^! at#� z 'p'ha t ct n!+t * f r e ti ry� 'f'. Y� f }� i� ' Ct a� _ - -ot c fz t�., , 'c p c f ,,# Jt y . y d4 ' V ry �1 d �,. a ' +� .1� ;, T'�451 ' k `Y4 f '.\ { t t ,,5`. ✓ ay ! t � 1 r; i .x +A �'+ -,�j` �p`�. � k ' 0 , r , ! , ,� 3 5 4k jf, i ,, K fi I .h.g,t `� ,14-10;4 7s , y.:`, 5'i ' � •: - ! ' ' .K. f > � i % a ' d ,yi.. yttN xv "' Y,' Y 4 rw' t ! T tr Yt 4 1 ,'. A r)7 11� ' , x . i. k t , r , 1 � " 31 t -- t € '< s• li 'Wit-4V., � l� . fk'h i ?yz' ��, t, 1 � i ' ^ ," A O { 1 4 VI a T' '� Vt 1 4 s sl p t � '1' 7 x . ,0 i'1f 44:4; k "' e4. x� �V rt ''. ,L. f 3tf t `h 'K !y a r"". a �,Y,f .1e l' k k � 4 r ,C t o a 5 r :f i r : r + r n r � k Y2c n-rs +T� Y j�v :' L p ++�7 5 �' fy t, r y 4 - { � , ? b : yrl r .e+ # t `���t ! r3 ' t �,yll y � - n t r r ay . { lV1 �i� �,'9t ` !( i s K �p,' �" f . i.� S � I } s •(� .t4.44, , ® d ` 'i, '" , .J�tlrc� ,y) )3!F �F } ` , ` 1 " x a ^ ' " �., itu r F,f'�I� • * r , ;I It ' q x u * ` �� �� - r ' trlL x ` : • iii Efl r + y t 't i.ra fh7 .y, ' Y -4 ; �7 1 ! ` s ,r E fii�ry l .� '?4 ra 3 ' %' k $ 1 t r 1 Y . >' - k ! 1 a s � IlS' j'f , s 1144 f t�r 444: f nO ! -tY ' T r 1 � i r h o $� 1� y C , t ,t +1 x -+ ar yi 7 . tT % r r ;+, r y , , V5 ref AI411. 1 � � ,`�_� p . -. itak � j * ^ 3 -4,-6:14.e. ct+`.+ h1', `0�u{fa- JM11 1'?t'' u'Y'�i + ?i Ymii i. - SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3 -3 3 -1 -04 REV. 7 OEM RELEASE/BRACKET ASSEMBLY TWO TANK ENCLOSURE ASSEMBLY (FOR OEM IN- CABINET USE ONLY) The Two Tank Enclosure Assembly, Part No. 429872, consists of The OEM Regulated Mechanical Release /Bracket Assembly, Part two expellant gas hoses, two grommets, and the mounting enclo- No. 79493, contains the same regulated release mechanism as sure. The assembly is used in 9 gallon systems. It can be coupled the standard ANSUL AUTOMAN Regulated Release Assembly. with a 3- gallon regulated release assembly or a 3- gallon regulated The OEM Regulated Electrical Release /Bracket Assembly, Part actuator assembly to give a total of 9 gallons of agent. Agent tanks No. 418054, is identical to the mechanical version except it con- must be ordered separately. tains a factory installed 120 VAC solenoid and electrical switch. The tank enclosure is designed to mount in a minimum amount of These release /bracket assemblies must be installed in a suitable space. equipment enclosure either horizontally or vertically. They contain all the necessary mounting and conduit holes needed to fully install the assembly. The agent tank is installed separately and need not be bracketed once it is piped and filled. NOTE: OEM • Release /Bracket Assembly must be installed high enough in cabi- net so that there is sufficien • - • - • - 1 and remove cartridge. SH IPPING WT. 26 LBS. (12 kg) , • ro MOUNTING ELEASE I 0 BRACKET ECHANISM -y �� 1 , j 0 FIGURE 10 REGULATOR "IP 002277 i1 24 VDC REGULATED RELEASE ASSEMBLY (ULC APPROVED SHIPPING WT. ONLY) I0 10 LB. (5 kg) The 24 VDC Regulated Release Assembly, Part No. 429859, is used where electric, thermostat detection is required via the use of FIGURE 8 a releasing control unit. This assembly consists of a 24 VDC Oco,.$ ANSUL AUTOMAN II -C regulated release mechanism, expellant gas hose, and enclosure knockouts to facilitate installing actuation OEM REGULATED ACTUATOR ASSEMBLY piping, expellant piping, detection system, and additional equip - The OEM Regulated Actuator Assembly, Part No. 418691, ment. Agent tank must be ordered separately. includes the regulator, pneumatic actuator, expellant gas hose and The system can be actuated automatically or manually. Automatic OEM bracket. Also available is an OEM Regulated Actuator actuation occurs when the control panel receives a signal from the Assembly with all the above mentioned components except for the detection circuit. The panel then sends an electrical signal to the bracket. This assembly is Part No. 418522. 24 VDC regulated release, causing it to actuate. When actuation occurs, the gas cartridge is punctured, pressurizing the agent tank and discharging the agent through the distribution piping. Manual �t. actuation of the system occurs when personnel pull on the remote i manual pull station pull ring. � Ill ® O NOTE: AGENT TANK MUST BE 1,1 t�C�, ` ORDERED SEPARATELY -;'I' SHIPPING WT. I 34 LB. (15 kg) fli Or N f fir' SHIPPING WT. 4 LB. (2 kg) FIGURE 9 002225 FIGURE 11 002279 ' SECTION III — SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-4 REV.6 3 -1 -04 ADDITIONAL SHIPPING ASSEMBLIES GAS CARTRIDGES Several complete shipping assemblies are available containing The R -102 system uses gas cartridges to store nitrogen or carbon both the release or actuator mechanism and the agent tank. When dioxide expellant gases under pressure until the system is actuat- ordering a complete shipping assembly, order the following part ed, at which time the cartridge seal is punctured and the released numbers: gas expels liquid agent from one or more tanks through the dis- Shipping Wt. charge piping and out the discharge nozzles. Part No. Description Ib. (kg) Four nitrogen gas cartridges and three carbon dioxide gas car - 430299 3.0 Gallon Mechanical Release 33 (15) tridges are available as shown in Figure 12. Shipping Assembly including: Cartridges noted as TC /DOT are both Transport Canada (TC) and 429853 Mechanical Regulated Department of Transportation (DOT) approved. Cartridges noted Release Assembly as DOT are Department of Transportation approved only. 429862 3.0 Gallon Tank Assembly Cartridge selection options are provided in Section IV under Tank 430300 1.5 Gallon Mechanical Release 30 (14) and Cartridge Requirements. Shipping Assembly including: NITROGEN GAS CARTRIDGES 429853 Mechanical Regulated Release Assembly 429864 1.5 Gallon Tank Assembly } I } 430309 3.0 Gallon Regulated Actuator 36 (16) (zD �) 11 3/8 I 10 ■ /2 IN. Shipping Assembly including: (28.9 cm) (27 m) 14 5/8 IN. 7 7/8 IN. 429850 Regulated Actuator Assembly (37.1 cm) 429862 3.0 Gallon Tank Assembly 2 1/2 IN. 430316 1.5 Gallon Stainless Steel Enclosure 18 (8) (64 cm) 2 1/2 IN 4 3/16 IN Shipping Assembly including: (6.4 cm) (10.6 cm) 429870 Single Tank Mounting Box 3 9/16 IN. Assembly (9 cm) 429864 1.5 Gallon Tank Assembly LT -20 -R LT -30 -R DOUBLE -TANK LT -A- 101 -30 CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE 418511 Hose Assembly PART NO. 423429 PART NO. 423435 PART NO. 423493 PART NO. 423491 (TC /DOT) (TC /DOT) (TC /DOT) (TC /DOT) 430317 3.0 Gallon Stainless Steel Enclosure 20 (9) 000145 000146 000,47 000148 Shipping Assembly including: 429870 Single Tank Mounting Box CARBON DIOXIDE CARTRIDGES Assembly 429862 3.0 Gallon Tank Assembly I 418511 Hose Assembly 430324 6.0 Gallon Stainless Steel Enclosure 40 (18) 9 1N. 7 7/8 1N. Shipping Assembly including: (22 9 cm) (20 cm) 11 5/8 IN 429872 Two Tank Mounting Box (29.5 cm) Assembly II-0. 429862 3.0 Gallon Tank Assembly (2) - 430332 3.0 Gallon Mounting Bracket Shipping 20 (9) (5.1 cm) (6.4 cm) Assembly including: 429878 3.0 Gallon Mounting Bracket (6,4 cm) Assembly 101 -10 CARTRIDGE 101 -20 CARTRIDGE 101 -30 CARTRIDGE 429862 3.0 Gallon Tank Assembly PART NO. 423439 (TC /DOT) PART NO. 423441 PART NO. 423443 PART NO. 15850 (DOT) (TC /DOT) (TC /DOT) 000149 000150 000151 FIGURE 12 - SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -1 10 -1 -02 REV. 5 SYSTEM DESIGN • GENERAL INFORMATION The Ansul R -102 Restaurant Fire Suppression System may be 1. Nozzles must be located 2 -8 in. (5 -20 cm) into the center of the used on a number of different types of restaurant cooking appli- duct opening, discharging up. See Figure 1. ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre - engineered system. Those individuals responsible for the design of the R -102 system must be trained and hold a current Ansul certificate in an R -102 training program. The R -102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R -102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R -102 or PIRANHA Regulated Actuators. In systems utilizing a All 11 111111111111*. 101 remote release, any combination of the maximum number of regulated actuators can be used. (5 - 2IN. m) • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. 000173 • Adjacent appliances requiring protection must be protected 2. In installations where a UL listed damper assembly is with the same type of system, either R -102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in. unless the center - to-center spacing between the adjacent (20 cm) maximum, to a point just beyond the damper assem- R -102 and PIRANHA nozzles is no less than 36 inches. bly that will not interfere with the damper. Exceeding the max- • When appliances are protected with R -102 nozzles, the hood imum of 8 in. (20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3. Previously listed 3 flow number and 5 flow number duct pro- • Mixing systems in a common plenum is not allowed. n e ai a in�ariter -published - manual _Part _No. 418087- 06, can also still by utilized. '--_" One of the key elements for restaurant fire protection is a correct/ system design. This section is divided into ten sub - sections: Noi- DUCT SIZES UP TO 50 IN. (127 cm) zle Placement Requirements, Tank Quantity Requirements, Act PERIMETER/ 16 IN. (41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Pipng OR yW O5 €E g. LET,,., v;, Sof36 Requirements, Detection System Requirements, Manual Pull a- • One 1100 nozzle (Part No. 430912) = one flow number J tion Requirements, Mechanical Gas Valve Requirements, Elec i 50 in (127 cm) perimeter maximum / cal Gas Valve Requirements, Electrical Switch Requirements, an Pressure Switch Requirements. Each of these sections must be • 16 in. (41 cm) diameter maximum __ _--- completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN. (254 cm) during installation. PERIMETER/ 32 IN. (81.3 cm) DIAMETER • NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle (Part No. 419337) = two flow numbers This section gives guidelines for nozzle type, positioning, and • 100 in. (254 cm) perimeter maximum quantity for duct, plenum, and individual appliance protection. This • 32 in. (81.3 cm) diameter maximum section must be completed before determining tank quantity and • A 2WH nozzle (Part No. 78078) must be substituted for a 2W piping requirements. nozzle for any installation using Option 2 of the 1.5 gallon sys- Duct Protection — Single Nozzle tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi - All duct protection is UL listed without limitation of maximum duct mum diameter of 24 in. (61 cm) of coverage. length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to The chart below shows the maximum protection available from the horizontal and ducts with directional bends. each duct nozzle. The R -102 system uses different duct nozzles depending on the Part 3.0 Gallon 1.5 Gallon . size of duct being protected. Description No. System System 2W Nozzle 419337 Maximum Maximum 100 in. (254 cm) 100 in. (254 cm) - - Perimeter - - -- Perimeter , 1100 Nozzle 430912 Maximum Maximum u t� 50 in. (127 cm) 50 in. (127 cm) --) -W Nc- LG Perimeter Perimeter SECTION IV — SYSTEM DESIGN • UL EX. 3470 ULC CEx747 Page 4 -5 10 -1 -02 REV. 3 Plenum Protection The R -102 system uses the 1W Nozzle (Part No. 419336) or the f i l • 1100 Nozzle (Part No. 430192) or the 1N Nozzle (Part No. 1 t 419335) for plenum protection. The 1W nozzle tip is stamped with 20 IN. (51 cm) MAXIMUM • 1W and the 1N nozzle tip is stamped with 1N, indicating they are 1 one -flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be „. protected regardless of filter length. i MINIMUM • VERTICAL PROTECTION — GENERAL r:7 . One 1W nozzle or 1100 nozzle will protect 4 linear feet (1.2 m) of t plenum. The maximum distance from the end of the hood to the MAxIM511vicm) first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The f . plenum width must not exceed 4 ft. (1.2 m). (The 1 W or 1100 noz- , IN(2.5 cm) zle can be sed on single or V -bank filter arrangements.) See MINMUM . Figure 6. 1 FIGURE 7 2 FT. (.6 m) 000lss MAXIMUM 4 FT. (1.2 m) Option 2: The 1W or 1100 nozzle must be placed perpendicular, MAXIMUM ► 4 FT (12 m) ... .....--- ----4 FT. (1.2 m) 8 -12 in. (20 -30 cm) from the face of the filter and angled 2 FT. (.6 m) MAXIMUM MAXIMUM to the center of the filter. The nozzle tip must be within MAXIMUM 2 in. (5 cm) from the perpendicular center line of the fit- ✓ '�,. ter. See Figure 8. - 12 IN. (30 cm) 4 IN. of Alk0 MAXIMUM (10 cm) I r // r 6 IN. / I /' I� if MINIM UM cm) �, ( �� NOZZLE TIP •••� t MUST BE WITHIN ���� ■ FIGURE 6 THIS AREA ::' 00019] Air . When protecting plenums with the 1W or 1100 nozzle, two options LOP of coverage are available: FIGURE 8 � 000200 • Option 1: The 1100 or 1W nozzle must be on the center line of the — _ -- ---.__ single or "V" bank filter and positioned within 1 -20 in. HORIZONTAL PROTECTION — OPTION 1 - -- (2.5-51 cm) above the top edge of the filter. See ' ► EC `- 1N NOZZLE — PART NO. 419335 — SINGLE BANK PROTEC Figure 7. TION One 1N nozzle will protect 10 linear feet (3.1 m) of single filter bank • plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. See Figure 9. • •',_ 2 -4IN. 10 FT. (3.1 m) �; (5 - 10 cm) MAXIMUM I IL 1 000201 \i il---0 j l .-. lir 000202 \ - FIG E 9 • • SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -8 REV. 5 10 -1 -02 Fryer — Single Nozzle Protection (Continued) Maximum Area Dimensions — Single Nozzle Fryer Protection Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 230 27 in. to 47 in. See Figure • 14 in. x 15 in. 14 in. x 21 in. (69 cm to 119 cm) 15 and 16 5 cm_x- (36-ern-x-.53-cm)-- „-- . , Full or Split Vat Full or Split Vat 245 20 in. to 27 in. See Figure i • 14 in. x 15 in. 14 in. x 21 in. (51 cm to 69 cm) 15 and 16 (36 cm x 38 cm) (36 cm x 38 cm) I I I I I 1 1 II I I I 1 i I I I I i 1 II I 1 I II 1 I I I 1 ii TOP OF FRYER / TOP OF FRYER I I 401i •d I/, • 1114101000 %oil 11111441.11111111111""- - FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SPLIT VAT SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. e. FIGURE 15 ► FIGURE 16 oonao 002283 • SECTION IV – SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -20 REV. 4 10 -1 -02 % 2 -Flow Griddle Protection (Continued) � . 1 Option 2 – Nozzle Perimeter Located (Continued) Medium Proximity Application: 20 in. to 30 in. (51 cm to 76 cm) above the cooking surface. The medium proximity application uses the 290 nozzle, Part No. 1 419342. ', The nozzle tip is stamped with 290 indicating this is a two -flow nozzle and must be counted as two flow numbers. One 290 nozzle will protect a maximum cooking area of 1440 sq. in. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in. (5.1 cm) inside perimeter, and aimed at the center of the cooking surface. See Figure 41 and 42. ��— COOKING AREA TT CENTER OF I COOKING SURFACE r _ I f COOKING • I �� AREA —.8. I -a-- AIM POINT I— — _ ____— j J 1 290 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0 - 2 IN. (0 - 5 cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT CEN- TER OF COOKING SURFACE. FIGURE 41 • 00014, I NOZZLE LOCATION t 1 0- 21N.(0 -5cm) 1 I 1 INSIDE PERIMETER 1 30 IN t••— OF COOKING SURFACE 1 1 (76 an) ( MAXIMUM / 1 HEIGHT 1 1 OF 0 NOZZ TIP 1 I 20 IN. (51 cm) / / I 1 MINIMUM / 1 I HEIGHT 1 1 I OF 290 11 i � NOZZLE TIP I I EDGE OF COOKING ING SURFACE 1I • FIGURE 42 000243 • TYCO SAFETY PRODUCTS ® ONE STANTON STREET ANSUL u MARINt 1 t, WI 54143.2542 e � i 715 735 741 1 - ° -- wowv.ansu .corn GENERAL BULLETIN NO. 5081 DATE: March 30, 2006 TO: ALL ANSUL® Authorized Restaurant System Distributors and OEMs FROM: Mark Neumann — Marketing Manager, Restaurant Systems SUBJECT: 1W Nozzle replaces 1100 Nozzle Effective immediately for ANSUL R -102 fire suppression systems: the 1W nozzle is now listed and approved for all applications currently being protected with the 1100 nozzle. The change will be reflected in the next revision of the ANSUL R -102 Design, Installation Recharge and Maintenance Manual. Upon depletion of the current inventory, the 1100 nozzle (Part No. 430913 — 25 pack; and Part No. 419336 — single) will be discontinued. If you have questions pertaining to this bulletin, please contact you U.S. District Manager, International Area Manager, or call Technical Services at 1- 800 - 862 -6785 / 1- 715 - 735 -7415.