Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT DEVELOPMENT SERVICES PERMIT #: MEC2005 -00090 "�� 13125 SW Hall Blvd., Tigard, O R 97223 (503) 639 -4171 DATE ISSUED: 3/7/2005 PARCEL: 2S1 13AD -01900 SITE ADDRESS: 16600 SW 72ND AVE B10 SUBDIVISION: OREGON BUSINESS PARK I ZONING: I -L BLOCK: LOT: 009 JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: 1 DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Remarks: condensing unit replacement. Owner: FEES PACIFIC REALTY ASSOCIATES Description Date Amount 15350 SW SEQUOIA PKWY #300 -WMI [MECH] Permit Fee 3/7/2005 $77.10 PORTLAND, OR 97224 [TAX] 8% State Surchar€ 3/7/2005 $6.17 Total $83.27 Phone: Contractor: ACCURATE HEATING, INC. P.O. BOX 2276 REQUIRED ITEMS AND REPORTS CLACKAMAS, OR 97015 Phone: 650 - 1229 Reg #: LIC 88423 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -001 through OAR 952-001-0100. You may obtain cop of these rule •- direct questions to OUNC by ca ling (5F) • . \ Issued By: - -c--- Permittee Signature: X f \ Call (503) 639 -4175 by 7:00 P.M. for inspections needed the next busi , -ss day. This permit card shall be kept in a conspicuous place on the job site until compl :,tion of the project. Approved plans are required on the job site at the time of each inspection. Merchanical Permit Appli iu t, 1 \i , FOR OFFICE USE ONLY . City of Tigard Received Date/By: ' ( c— 6 • Permit No.: • 13125 SW Hall Blvd., Tigard, OR 97223 MAR 0 7 v_- — o ' — 6)(.)i% I " Plan Review Phone: 503.639.4171 Fax: 503.598.1960 D/B Other Permit: Inspection Line: 503.639.4175fi�li Date/By: p� �. Date Ready /By: ® See Page 2 for Internet: www.ci.tigard.or.us L1 Y 01- f 3 - Notified /Method: Supplemental Information BUILDING :DIVISION TYPE OF WORK COMMERCIAL FEE* SCHEDULE – USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction ® Addition /alteration /replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. CATEGORY OF CONSTRUCTION Value: $ $2,200.00 RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ I - and 2- family dwelling ® Commercial /industrial ❑ Accessory building For special in formation use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description 1 Qty. I Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling Job site address: 16600 SW 72ND Air conditioning or heat pump (requires site plan showing placement) 14.00 City /State /ZIP: TIGARD, OREGON Furnace 100,000 BTU (ducts /vents) 14.00 Furnace 100,000+ BTU (ducts /vents) 17.90 Suite /bldg. /apt. no.: Project name: FLIGHT DYNAMICS Gas heat pump 14.00 Cross street /directions to job site: DURHAM TO 72ND Duct work 14.00 Hydronic hot water system 14.00 Residential boiler (radiator or hydronic) 14.00 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 10.00 Subdivision: Lot no.: Flue /vent for any of above 10.00 Other: 10.00 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 10.00 Gas fireplace 10.00 REPLACE ONE EXISTING CONDENSING UNIT WITH NEW. Flue vent for r water heater or gas fireplace 10.00 ' Log lighter (gas) 10.00 Wood /pellet stove 10.00 Wood fireplace /insert 10.00 ❑ PROPERTY OWNER ❑ TENANT Chimney /liner /flue /vent 10.00 Other: 10.00 Name: FLIGHT DYNAMICS Environmental exhaust and ventilation Address: 16600 SW 72ND Range hood /other kitchen equipment 10.00 City /State /ZIP: TIGARD, OREGON Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 6.80 ❑ APPLICANT ❑ CONTACT PERSON Attic /crawlspace tans 10.00 Other: _ 10.00 Business name: ACCURATE HEATING, INC. Fuel t m P g Contact name: MICHAEL BLACKMON JR. $5.40 for first four; $1.00 for each additional Address: PO BOX 2276 Furnace, etc. Gas heat pump City /State /ZIP: CLACKAMAS, OREGON 97015 Wall /suspended /unit heater ,1 Phone: (503) 650.1229 Fax: : (503) 650.4845 Water heater . " ! r 5D Fireplace JpU E - mail: MBLACKMONJR @ACCURATEHEATING.COM Range CONTRACTOR Barbecue Business name: ACCURATE HEATING, INC. Clothes dryer (gas) Other: Address: PO BOX 2276 MECHANICAL PERMIT FEES* City /State /ZIP: CLACKAMAS, OREGON 97015 Subtotal 77 /) Phone: (503) 650.1229 Fax: (503) 650.4845 Minimum permit fee ($72.50) Plan review (25% of permit fee) CCB lic.: 88423 State surcharge (8% of permit fee) 6, , t TOTAL PERMIT FEE 5- 3 ,ai This permit application expires if a permit is not obtained within IS Authorized signature: days after it has been accepted as complete. Print name: MICHAEL BLACKM • JR Date: 3.7.05 * Fee methodology set by Tri- County Building Industry Service Board i ".Ruildin 'Permit. \MFF- PerrnitAnn.dnc 12/01 440 -4517T (11 /02/COM /WFRI 561C (60 Hz) B r y a n t\ ELECTRIC AIR CONDITIONER Sizes 018 thru 060 Hang& Ceding Systems Model 561C Energy - Efficient Air Conditioners incorporate inno- . vative technology to provide reliable summer cooling perfor- 400 F , ` mance. Built into these units are the features most desired by `, QQ1 homeowners today including SEER ratings of up to 10.5 when �- ed with components designated by manufacturer. All models t� �� ted with UL, c -UL, ARI, CEC, and CSA -EEV. c, `ANS AVAILABLE OPTIONS `C3 UNIT DESIGN— Copper tube, enhanced sine wave aluminum G �‘ fin coil is designed for optimum heat transfer. Vertical air dis- �� charge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump -style base pan for easy removal of water, dirt, and leaves. ELECTRICAL RANGE —All units are offered in 208 -230v sin - %.'fit « ,!i� �� -4 11 � ; gle phase. Three -phase units are available from 030 through 1` j�1 � `((_ _ � ��� 060 sizes in 208/230v and from 036 through 060 sizes in 460v. • • _ ! ' WIDE RANGE OF SIZES —The 561C is available in 8 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. li I , I WEATHER- PROTECTIVE CABINET —The steel panels are I protected with a galvanized coating then covered with a layer of lj ; „ zinc phosphate. A modified polyester powder coating is then I applied and baked on, providing each unit with a hard, smooth �I a 3 I finish that will last for many years. � . All screws on cabinet exterior are coated for a long- lasting, rust- resistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR—Means greater reliability ) under rain conditions and dependable performance for many years. The permanent- split-capacitor -type motor was designed i ' ) " for optimum efficiency. The motor was then qualified under extreme conditoins to help ensure a long, reliable life. APPLICATION VERSATILITY —The unit can be combined with a wide variety of evaporator coils and blower packages to pro- vide L - quiet, dependable comfort. Unit can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES —The service valves are brass, front seating type. The 561 C has sweat field connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY —One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. COMPRESSOR PROTECTION —Each compressor is pro- tected with internal temperature- and current - sensitive over- loads. An internal pressure relief valve provides high - pressure protection to the refrigerant system. LIMITED WARRANTY — Standard 1 -year warranty on parts, with a 5 -year limited warranty on the compressor. Form No. PDS 561C.18.7 • A so AIR DISCHARGE M AIR IN _ AIR DISCHARGE Ii �#� TT 1 FIELD POWER SUPPLY CONN 7 /e-IN. DIA HOLE WITH \ ° ° - 1 1 /3-IN. DIA KNOCKOUT N ` J 111111 AND 1 3 /8-IN. DIA KNOCKOUT ��� � ' / . I � ` K AIR IIL•�11 FIELD CONTROL SUPPLY AIR IN � 1�1� 1 1 A - - - -- - L CONN 7 /8-IN. DIA HOLE `��1�! �� ``` ,T , 1ll� 11/ B M 1111,1111 3 /8-IN. DIA j � ` {� TIEDOWN , A � ,�If' ,,,� ./ G��I�lILl7g \ � \ 3 /9 -IN. DIA LIQUID �� (2) KNOCKOUTS PLACES �� ���� 1 �I 0. ' I I LINE CONN • 1 • 9 0 AIR DISCHARGE 1 I 1 t�71•� • i'•9 2 7/8" C E AIR IN F - mil D DIA VAPOR LINE CONN 1 1 /4" G H NOTES: p 1. Allow 30 in. clearance to service side of 3 unit, 48 in. above unit, 6 in. on one side, 12 in. R1 on remaining side, and 24 in. between units for proper airflow. z 2. Minimum outdoor operating ambient in cooling mode is co 55°F, max. 125 °F. 3. Series designation is the 14th position of the unit 0 model number. 4 . Center of gravity S. z N 11 J A97017 0 DIMENSIONS (IN.) UNIT DIMENSIONS MINIMUM UNIT - MOUNTING SIZE SERIES A B C D E F G H J K L M N P PAD DIMENSIONS 018 E 18 21 -15/16 3 -3/16 5/8 3 15 16 -5/16 17 -3/4 10 -3/16 16-1/8 17 -3/4 7 -7/8 8 -3/8 9-3/8 18 X 18 024 E 18 23 -15/16 3 -3/16 5/8 3 15 16 -5/16 17 -3/4 10 -3/16 16-1/8 17 -3/4 7 -7/8 8 -3/8 9 -1/2 18 X 18 030 A,E 22 -1/2 21 -15/16 3 -3/16 3/4 3 -11/16 18 -1/8 19 -3/4 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10 -3/8 10 -1/4 10 -3/4 22 -1/2 X 22 -1/2 036 B 22 -1/2 25 -15/16 3- 3/16 3/4 3 -11/16 18 -1/8 19 -3/4 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-1/4 9 -1/2 11 -1/4 22 -1/2 X 22 -1/2 036 E 22 -1/2 25 -15/16 3 -3/16 3/4 3 -11/16 18 -1/8 19 -3/4 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-3/8 10 -3/4 11 -1/4 22 -1/2 X 22 -1/2 036 F 22 -1/2 23 -15/16 3 -3/16 3/4 3 -11/16 18 -1/8 19 -3/4 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-3/8 10 -3/4 11 22 -1/2 X 22 -1/2 042 E 22 -1/2 27 -15/16 3 -1/4 7/8 3 -11/16 18 -1/8 19 -13/16 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-3/8 10 -3/4 11 -1/8 22 -1/2 X 22 -1/2 042 B 22 -1/2 29 -15/16 3 -1/4 7/8 3 -11/16 18-1/8 19 -13/16 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-3/8 10 -3/4 11 -1/8 22 -1/2 X 22 -1/2 047 A 22 -1/2 29 -15/16 3 -1/4 7/8 3 -11/16 18 -1/8 19 -13/16 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10-3/8 10-3/4 11 -1/8 22 -1/2 X 22 -1/2 048 F 22 -1/2 29 -15/16 3 -1/4 7/8 3-11/16 18 -1/8 19 -13/16 22 -1/4 14 -3/8 19 -9/16 22 -1/16 10 -3/8 10 -3/4 11 -1/8 22 -1/2 X 22 -1/2 060 H 30 33- 15/16 3-1/4 7/8 6 -1/2 23 -1/2 27 -1/4 29-3/4 20 27 -1/16 29 -9/16 15 -1/2 14 15 30 X 30 CHECK -FLO- RATER® PISTON CHART PISTON' UNIT SIZE IDENTIFICATION NO. 018-E 52 024 -E 59 030 -A 67 036 -E, F 73 036 -B 70 042 -E 78 042 -B 82 047 -A 80 048-F 80 060 -H 90 * Piston listed is for any approved coil non - capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter (In.) Vapor Tube Diameter (In.) UNIT 0 to 50 Ft 0 to 50 Ft Long -Line Applications* SIZE Tube Length Long -Line Applications* Tube Length (Maximum Diameter) 018, 024 _ 5/8 3/4 _ 030, 036 3 318 3/4 7/8 042-048 7/8 - 1 -1/8 060 1 -1/8 1 -1/8 * For tube sets between 50 and 175 ft, consult Residential Split System Long -Line Application Guideline. SOUND POWER (dBA) UNIT SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL (dBA) 125 250 500 1000 2000 4000 8000 018 -E 80 58.0 64.0 68.5 72.5 71.5 68.0 60.0 024 -E 80 59.5 65.5 70.0 74.0 71.0 69.5 60.5 030 -A 80 55.0 62.5 73.5 74.0 71.0 67.5 59.5 030 -E 80 55.0 64.5 71.0 72.0 70.5 69.0 62.5 036 -B 82 55.0 64.0 73.0 74.5 72.0 68.5 64.0 036-E 82 56.5 70.0 73.5 75.5 74.5 71.0 65.0 036 -F 82 55.5 66.5 70.5 74.5 73.5 70.0 63.5 042 -B 82 59.0 66.5 68.5 75.5 71.5 73.0 65.5 042 -E 82 54.5 67.0 69.0 73.0 72.5 71.5 63.0 047 -A 82 58.5 65.0 69.0 76.0 73.5 71.0 63.0 048-F 82 56.5 69.0 67.5 73.0 72.5 72.5 64.0 060 -H 82 58.0 67.5 72.0 76.0 76.0 73.0 67.0 eS.' 4 , Cor t 0...4. ti -r APPROVALS ,�, „ ,,. ISO 9001 ` S EN 29001 ct c ` ' O L us q s jE: 0 lf o �� PART 1 091 r'••' +4A" 1 .. CERTIFICATE NO. FIN 28768 CERTIFICATION APPLIES ONLY REGISTERED QUALITY SYSTEM WHEN THE COMPLETE SYSTEM /� IS LISTED WITH ARI. -'∎�. III liillAk -3- SPECIFICATIONS UNIT SIZE-SERIES ';'- ; y ' ,. ,561C0 s561CO24E +, „„ . , , -.561CO30 -E , Operating Weight Lb) 115 117 122 124 ,.ELECTRI . •, :„ , , . '' ,, ._. ' .r_ i Unit Volts – Mertz —Phase 208 -230 -60-1 208/230 -60-3 Operating Voltage Range* 197 -253 187 -253 Compressor —Rated Load Am.s 9A 11.6 14.1 9.4 Locked Rotor Amps 48.0 60.0 73.0 68.0 Condenser Fan Motor —Full Load Amps 0.8 1.0 0.8 0.8 Min Unit Ampacity for Wire Sizing 12.1 15.5 18.4 12.6 Min Wire Size (60 °C Copper AWGt 14 Min Wire Size (75 °C Copper) AWGt 14 Max Wire Length (60 °C) (Ft)$ 61 49 41 70 Max Wire Length (75 °C) (Ft)$ 58 47 39 65 Max Branch Circuit Fuse Size** 20 20 30 15 COMPRESSOR & "REFRIGERANT " Compressor— Manufacturer Bristol Copeland Type Reciprocating Temperature and Current Protection Internal Line Break Refrigerant —T • • and Amount @ 15 Ft R -22 and 3.30 R -22 and 3.65 R -22 and 4.25 R -22 and 4.19 CONDENSER COIL& FAN _” Coil Face Area (Sq Ft) 6.18 6.8 7.45 Fins Per In.— Rows --- Circuit 20-1 -1 22 -1 -1 20 -1 -2 25 -1 -2 Fan Motor —PSC Type, HP and RPM 1/8 and 1500 1/6 and 1500 1/10 and 1100 1/10 and 1125 Volts— Hertz —Phase 208/230 -60 -1 Condenser Airflow (CFM) 1500 1600 2000 2000 OPTION EQUIPMENT Coastal Filter KAACF0701SML KAACF1001MED Time -Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA Inlet Grille Kit KSABG0105CMC KSABG0205CMC KSABG0604CSM Start Assist—Capacitor /RelayT pett KSAHS2001AAA KSAHS2001AAA KSAHS0901AAA N/A Start Assist —PTC Type KAACS0201 PTC N/A Sound Hood N/A TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB TXV (Hard Shutoff) KSATX0601HSO Low - Pressure Switch KAALP0101LPS High - Pressure Switch KSAHI0101HPS Filter Drier (RCD) P502 -8083S Evaporator Freeze Thermostat KAAFT0101AAA Liquid -Line Solenoid Valvett KAALS0101LLS Winter Start Control$$ (RCD) KAAWS0101AAA MotorMaster® Control*** (RCD) N/A 32LT660004 Ball Bearing Fan Motor N/A HC34GE232 Thermostat, Auto Changeover, Non - Programmable, °F/°C, 1 -Stage Heat, 1 -Stage Cool TSTATBBNAC01 -B Thermostat, Auto Changeover, 7 -Day Programmable, °F / °C, 1 -Stage Heat, 1 - Sta•e Cool TSTATBBPAC01 -B Builder's Thermostat, Manual Changeover, Non - Programmable, °F / °C, 1 -Stage Heat, 1 -Stage Cool TSTATBBBAC01 -B Thermidistat Control, Programmable/ Non - Programmable Thermostat with Humidity Control TSTATBBPRH01 -B Outdoor Air Temperature Sensor TSTATXXSEN01 -B Backplate for Non - Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder's Thermostat TSTATXXBBP01 Thermostat Conversion Kit 4 to 5 wire TSTATXXCNV10 See notes on page 7. -4- SPECIFICATIONS Continued UNIT!SIZE= SERIES ., ? i61CO3GF_,' �561CO36 E �€ 56;ICO36 B ; � 56 GO 2 E - „ 561COt2 E "` : -�' Operating Weight (Lb) 138 129 138 138 142 ELECTRICAL - ;z_ ` ..z. .- . .? Unit Volts -Hertz -Phase 208 -230 -60-1 208/230 -60-3 460 -60-3 208 - 230 -60-1 208/230 -60-3 460 -60-3 Operating Voltage Range' 197 -253 187 -253 414 -506 197 -253 187 -253 414 -506 Compressor - Rated Load Amps 16.0 10.6 5.1 20.5 12.4 6.2 Locked Rotor Amps 82.0 75.0 33.0 115.0 90.0 42.0 Condenser Fan Motor -Full Load Amps 1.4 1.4 0.8 1.4 1.4 0.8 Min Unit Ampacity for Wire Sizing 21.4 14.7 7.2 27.0 16.9 8.6 Min Wire Size (60 °C Copper) AWGt 12 14 14 10 14 14 Min Wire Size (75 °C Copper) AWGt 12 14 14 10 14 14 Max Wire Length (60 °C) (Ft)$ 58 60 250 70 50 210 Max Wire Length (75 °C) (Ft)$ 55 55 238 70 50 200 Max Branch Circuit Fuse Size** 30 20 15 40 25 15 COMPR ESSOR & REFRIGERANT :. , ' Compressor- Manufacturer Bristol Copeland Copeland Scroll Tech Millennium Copeland Type Reciprocatin. Reciprocating Reciprocating Scroll Scroll Reciprocating Temperature and Current Protection Internal Line Break Refrigerant -T and Amount @ 15 Ft R -22 and 4.60 R -22 and 5.00 R -22 and 5.00 R -22 and 5.00 R -22 and 5.13 R -22 and 5.13 �C ONDENSER.;COIL & FAN Coil Face Area (Sq Ft) 8.28 9.93 Fins Per In.- Rows - Circuit 25-1 -2 25-1 -2 25-1 -2 22 -1 -2 22 -1 -3 25 -1 -3 Fan Motor -PSC Type, HP and RPM 1/4 and 1100 Volts- Hertz -Phase 208/230 -60 -1 460 -60-1 208/230 -60-1 460 -60 -1 Condenser Airflow (CFM) 2500 2500 OPTIONAL EQUIPMENT -,.,-,`-'1:----;'- L. . Coastal Filter KAACF1001MED Time -Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA KAACH1101AAA KAACH1201AAA KAACH1101AAA Inlet Grille IGt - KSABG0704CSM KSABG0904CSM KSABG1004AAA Start Assist-Capacitor/Relay T . - tt KSAHS0901AAA N/A KSAHS1501AAA N/A Start Assist -PTC Type KAACS0201 PTC N/A KAACS0201 PTC N/A Sound Hood KSASH2001BRL N/A KSASH1901CYL KSASH1201COP TXV (RPB) KAATX0501 RPB TXV (Hard Shutoff)tt KSATX0601 HSO Low - Pressure Switch KAALP0101 LPS High - Pressure Switch KSAHI0101HPS Filter Drier (RCD) P502 -8083S P502 -8163S Evaporator Freeze Thermostat KAAFT0101AAA Liquid -Line Solenoid Valvett KAALS0101 LLS Winter Start Control$$ (RCD) KAAWS0101AAA MotorMaster® Control"' (RCD) 32LT660004 32LT660005 32LT660004 321T660005 Ball Bearing Fan Motor HC40GE232 HC40GE462 HC40GE232 HC40GE462 Thermostat, Auto Changeover, Non - Programmable, °F / ° C, 1 -Stage Heat, 1 -Stage Cool TSTATBBNAC01 -B Thermostat, Auto Changeover, 7 -Day Programmable, °F / °C, 1 -Stage Heat, 1 -Stage Cool TSTATBBPAC01 -B Builder's Thermostat, Manual Changeover, Non - Programmable, °F/°C, 1 -Stage Heat, 1 -Stage Cool TSTATBBBAC01 -B Outdoor Air Temperature Sensor TSTATXXSEN01 -B Backplate for Non - Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder's Thermostat TSTATXXBBP01 Thermostat Conversion Kit 4 to 5 wire TSTATXXCNV10 See notes on page 7. -5- SPECIFICATIONS Continued UNIT SIZE;SERIE :`' , '., "x 56 1CJ047- A'3561CPO47 A 5610E047 A • , - ; a ',:.561C048 F -` 'c _ 'S61b060 H ' Operating Weight (Lb) 177 192 231 ELECTRICAL' E ` , .. T Unit Volts-Hertz-Phase 208 - 230-60 -1 208230-60.3 460-60-3 208 - 230-60-1 208230 -60- 460-60-3 208-230-60-1 208230.60 -3 460-60-3 Operating Voltage Range' 197 -253 187 -254 414 -506 197 -253 187 -253 414 -506 197 -253 187 -253 414 -506 Compressor- Rated Load Amps 21.8 12.8 6.4 24.4 14.1 7.1 28.8 16.0 8.0 Locked Rotor Amps 124.0 92.0 46.0 140.0 105.0 52.5 165.0 125.0 66.5 Condenser Fan Motor -Full Load Amps 1.4 1.4 0.7 1.4 1.4 0.7 1.4 1.4 0.7 Min Unit Ampacity for Wire Sizing 28.7 17.4 8.7 31.9 19.0 9.6 37.4 21.4 10.7 Min Wire Size (60 °C Copper) AWGt 10 14 14 8 14 14 8 12 14 Min Wire Size (75 °C Copper) AWGt 10 14 14 10 14 14 8 12 14 Max Wire Length (60 °C) (Ft)$ 69 44 88 97 41 79 82 57 72 Max Wire Length (75 °C) (Ft)t 66 42 83 59 39 75 78 54 68 Max Branch Circuit Fuse Size" 50 30 15 50 30 15 60 30 20 COMPRESSOR & REFRIGERANT ; ` Compressor- Manufacturer Scroll Tech Type Scroll Temperature and Current Protection Internal Line Break Internal Line Break Refrigerant-Type and Amount Qa 15 Ft R -22 and 6.13 R -22 and 6.13 R -22 and 8.31 CONDENSER COIL& FAN "° Coil Face Area (Sq Ft) 10.76 10.76 18.49 Fins Per In.- Rows -Circuits 25-1 -3 25-1 -3 25-1 -3 Fan Motor -PSC Type, HP and RPM 1/4 and 1100 Volts -Her1z -Phase 208/230-60-1 460 -60 -1 208/230 -60 -1 460 -60-1 208/230-60-1 460 -60-1 Condenser Airflow (CFM 2500 2500 3400 :,OPTIONAL :,EQUIPMENT, , , .n ». • 1. ?;:: `.. » . , . ,._ .`'` , hz _.,... ' .... Coastal Filter KAACF1001MED KAACF1001MED KAACF1101LRG Time -Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA KAACH130 ••CH1301 •.CH1301 Crankcase Heater KAACH1201AAA 1AAA KAACH1201AAA AAA KAACH1201AAA AAA Inlet Grille Kit KSABG1004CSM KSABG1704CMD KSABG1804CMD SAHS1601 SAHS1601 1 SAHS1601 Start Assist-Capacitor/Relay Typett AAA N/A AM N/A AM N/A ••CS0201 1 • • CS0201 ••CS0201 Start Assist -PTC Type PTC N/A PTC N/A PTC N/A Sound Hood KSASH2001CYL TXV Kit (RPB) KAATX0601RPB KAATX0601RPB KAATX0701RPB TXV (Hard Shutoff)tt KSATX0701HSO Low - Pressure Switch KAALP0101LPS High - Pressure Switch KSAH10101 HPS Filter Drier (RCD) P502 -8163S Evaporator Freeze Thermostat$$ KAAFT0101 AAA Liquid -Line Solenoid Valvett KAALS0101LLS Winter Start Control$$ KAAWS0101AAA MotorMaster D Control"' (RCD) 32LT660004 32LT66000 32LT660004 ,;: rrr. 32LT660004 32LT660005 Ball Bearing Fan Motor (RCD) HC40GE232 1 C40GE46- HC40GE232 HC40GE462 HC40GE232 HC4OGE• ;o Thermostat, Auto Changeover, Non - Programmable, °F / °C, 1 -Stage Heat, 1 -Stage Cool TSTATBBNAC01 -B Thermostat, Auto Changeover, 7 -Day Programmable, °F / °C, 1 -Stage Heat, 1 -Stage Cool TSTATBBPAC01 -B Builder's Thermostat, Manual Changeover, Non - Programmable, °F/°C, 1 -Stage Heat, 1 -Stage Cool TSTATBBBAC01 -B Outdoor Air Temperature Sensor TSTATXXSEN01 -B Backplate for Non - Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder's Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10 See notes on page 7. J * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. t If wire is applied at ambient greater than 30 °C (86 °F), consult Table 310-16 of the NEC (ANSI /NFPA 70). The ampacity of nonmetallic- sheathed cable (NM), trade name ROMEX, shall be that of 60 °C (140 °F) conductors, per the NEC (ANSI /NFPA 70) Article 336 -26. If other than uncoated (non - plated), 60 or 75 °C (140 or 167 °F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI /NFPA 70). # Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. Time -delay fuse or circuit breaker. tt Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 036 and 042, Series A; 048 and 060, Series A/B single phase; and all 3 -phase units). Do not use hard shutoff TXV with liquid solenoid valve. ## Use with low- ambient controller. " Fan motor with ball bearings required. N/A —Not Applicable NOTES: 1. All motors/compressors contain internal overload protection. 2. Copper wire must be used from service disconnect to unit. 3. Control circuit is 24v on all units and requires extemal power source. ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG -LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS ACCESSORY (Below 55 *F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yest No No Accumulator No No No Compressor Start Assist Yes Yes No Capacitor and Relay MotorMaster® Control Yes No No Wind Baffle See Low - Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended • ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW - AMBIENT LONG -LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS • ACCESSORY (Below 55 °F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yest No No Accumulator No No No Compressor Start Assist Yes Yes No Capacitor and Relay MotorMaster® Control Yes No No Wind Baffle See Low - Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid -Line Solenoid Valve See Long -Line or No Application No Hard Shutoff TXV Guideline Ball Bearing Fan Motor Yes No No * For tubing line sets between 50 and 175 ft, refer to Residential's Split Systems Long -Line Application Guidelines. t Only when low- pressure switch is used. ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low - Ambient Controller (full modulation feature) or MotorMaster® Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist — Capacitor /Relay Type Start capacitor and start relay which gives "hard" boost to compressor motor at each start -up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 °F (40.6 °C). Replacement installations with hard shutoff expansion valve on indoor coil. Installations where Liquid -Line Solenoid Valve has been added. 4. Compressor Start Assist —PTC Type Solid -state electrical device which gives a "soft" boost to compressor motor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 °F (12.8 °C) outdoor air temperature. (Use with Low - Ambient Controller.) All commercial installations. 6. Cycle Protector Solid -state timing device which prevents compressor rapid recycling. Control provides an approximate 5- minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to "play" with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High -rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze -up conditions. SUGGESTED USE: All units where Winter Start Control has been added. 8. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner: 1- direction flow. SUGGESTED USE: All split- system units. —7— ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 9. High - Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Installations exposed to very "dirty" outdoor air. Installations where condenser inlet air temperature exceeds 125 °F (51.7°C). 10. Inlet Grille Kit A field - installed enhanced inlet grille to replace the standard inlet grille on residential air conditioners and heat pumps. SUGGESTED USE: For greater protection against inclement weather, incidental damage, and vandalism. 11. Liquid -Line Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note: Compressor Start Assist – Capacitor /Relay Type must also be used. Do not use with hard shutoff TXV. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain long - line - applications. Refer to Long -Line Application Guideline. 12. Low - Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze -up due to loss of indoor airflow. Provides protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to "dirty" air. All commercial installations. 13. MotorMaster® Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –20 °F, it maintains condensing temperature at 100 °F ± 10 °F. SUGGESTED USE: Cooling operation at outdoor temperatures below 55 °F All commercial installations. 14. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat SUGGESTED USE: All corporate programmable thermostats. 15. Sound Hood Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dBA. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas — bedrooms, etc. Unit installed between 2 houses less than 10 ft apart. 16. Thermostatic Expansion Valve (TXV) A modulating flow - control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. IGt includes valve, adapter tubes, and extemal equalizer tube. Both hard shutoff and RPB valves are available. Do not use hard shutoff TXV with Liquid -Line Solenoid Valve. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 17. Time -Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 18. Winter Start Control An SPST delay relay which bypasses the low- pressure switch for approximately 3 minutes to permit start-up for cooling operation under low -load conditions. SUGGESTED USE: All air conditioners where Low - Ambient Controller has been added. —6— COMBINATION RATINGS FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CC5A/CD5AA018' 17,200 NONE - 10.00 10.00 9.15 CC5A/CD5AA024 17,800 NONE - 10.00 10.00 9.40 CC5A/CD5AW024 17,800 NONE - 10.00 10.00 9.40 CE3AA024 17,800 NONE - 10.00 10.00 9.45 CF5AA024 17,900 NONE - 10.00 10.00 9.50 CK3BA024 17,800 NONE - 10.00 10.00 9.55 CK5A/CK5BA018 17,200 NONE - 10.00 10.00 9.35 CK5A/CK5BA024 17,800 NONE - 10.00 10.00 9.55 CK5A/CK5BW024 17,800 NONE - 10.00 10.00 9.55 F(A,B)4AN(F,C)018 17,200 TDR 10.00 - 10.00 9.25 F(A,B)4AN(F,C)024 17,800 TOR 10.50 - 10.50 9.60 FC4BNF024 17,800 TDR &TXV 10.50 - - 9.65 FF1DNA018 17,200 TDR 10.00 - 10.00 9.45 FFIDNA024 17,800 TDR 10.50 - 10.50 9.50 FG3AAA024 17,800 NONE 10.00 - 10.00 9.35 FK4CNF001 17,800 TDR &TXV 11.00 - - 10.60 018-E FK4CNF002 18,000 TDR &TXV 11.50 - - 10.70 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA018 17,200 TDR 10.50 - 10.50 9.85 CC5A/CD5AA024 17,800 TDR 10.50 - 10.50 10.20 CE3AA024 17,800 TDR 10.50 - 10.50 10.20 CK3BA024 17,800 TDR 10.50 - 10.50 10.50 CK5A/CK5BA018 17,200 TDR 10.50 - 10.50 10.20 CK5A/CK5BA024 17,800 TDR 10.50 - 10.50 10.50 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CC5A/CD5AW024 17,800 TDR 10.50 - 10.50 10.25 CE3AA024 17,800 TDR 10.50 - 10.50 10.25 CK5A/CK5BW024 17,800 TDR 10.50 - 10.50 10.40 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AW024 17,800 TDR 10.50 - 10.50 10.30 CE3AA024 17,800 TDR 10.50 - 10.50 10.25 CC5A/CD5AA024' 23,600 NONE - 10.00 10.00 9.05 CC5A/CD5AA030 23,800 NONE - 10.00 10.00 9.05 CC5A/CD5AW024 23,600 NONE - 10.00 10.00 9.05 CC5A/CD5AW030 23,800 NONE - 10.00 10.00 9.05 CE3AA024 23,600 NONE - 10.00 10.00 9.10 CE3AA030 23,800 NONE - 10.00 10.00 9.20 CF5AA024 23,600 NONE - 10.00 10.00 9.10 CK3BA024 23,600 NONE - 10.00 10.00 9.15 CK3BA030 23,800 NONE - 10.00 10.00 9.15 CK5A/CK5BA024 23,600 NONE - 10.00 10.00 9.15 CK5A/CK5BA030 23,800 NONE - 10.00 10.00 9.15 CK5A/CK5BW024 23,600 NONE - 10.00 10.00 9.15 CK5A/CK5BW030 23,800 NONE - 10.00 10.00 9.15 F(A,B)4AN(F,C)024 23,600 TDR 10.00 - 10.00 9.20 F(A,B 4AN(F,C)030 23,800 TDR 10.00 - 10.00 9.35 FCCCCCC444444BNFF024 23,600 TDR &TXV 10.00 - - 9.20 FC4BNF030 23,800 TDR &TXV 10.00 - - 9.30 FF1DNA024 23,600 TDR 10.00 - 10.00 9.05 FF1DNA030 23,800 TDR 10.00 - 10.00 9.20 FG3AAA024 23,000 NONE 10.00 - 10.00 8.95 FK4CNF001 24,000 TDR &TXV 11.00 - - 10.05 FK4CNF002 24,400 TDR &TXV 11.00 - - 10.15 FK4CNF003 24,400 TDR &TXV 11.00 - - 10.30 COILS + 333(B,J)AVO36060 VARIABLE -SPEED FURNACE CC5A/CD5AA024 23,000 TDR 10.50 - 10.50 9.70 024 -E CC5A/CD5AA030 23,400 TDR 10.50 - 10.50 9.80 CC5A/CD5AW030 23,400 TDR 10.50 10.50 9.80 CE3AA024 23,000 TDR 10.50 - 10.50 9.75 CE3AA030 23,400 TDR 10.50 - 10.50 9.90 CK3BA024 23,000 TDR 10.50 - 10.50 9.85 CK3BA030 23,400 TDR 10.50 - 10.50 9.90 CK5A/CK5BA024 23,000 TDR 10.50 - 10.50 9.85 CK5A/CK5BA030 23,400 TDR 10.50 - 10.50 9.90 CK5A/CK5BW030 23,400 TDR 10.50 - 10.50 _ 9.90 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CC5A/CD5AW024 23,000 TDR 10.50 - 10.50 9.65 CC5A/CD5AW030 23,400 TDR 10.50 - 10.50 9.80 CE3AA024 23,000 TDR 10.50 - 10.50 9.70 CE3AA030 23,400 TDR 10.50 - 10.50 9.85 CK3BA024 23,000 TDR 10.50 - 10.50 9.75 CK3BA030 23,400 TDR 10.50 - 10.50 9.80 CK5A/CK5BW024 23,000 TDR 10.50 - 10.50 9.75 CK5A/CK5BW030 23,400 TDR 10.50 - 10.50 _ 9.80 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AW024 23,000 TDR 10.50 - 10.50 9.75 CC5A/CD5AW030 23,400 TDR 10.50 - 10.50 9.90 CE3AA024 23,000 TDR 10.50 - 10.50 9.80 CE3AA030 23,400 TDR 10.50 - 10.50 9.95 CK3BA024 23,000 TDR 10.50 - 10.50 9.95 CK3BA030 23,400 TDR 10.50 - 10.50 9.95 CK5A/CK5BW024 23,000 TDR 10.50 - 10.50 9.90 CK5A/CK5BW030 23,400 TDR 10.50 - 10.50 9.95 See notes on page 18. -9- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE - SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CD5A/CD5AA030' 28,000 NONE 10.00 10.10 10.10 9.10 CC5A/CD5AA036 29,000 NONE 10.00 10.10 10.10 9.30 CC5A/CD5AW030 28,000 NONE 10.00 10.10 10.10 9.10 CD5AW036 29,000 NONE 10.00 10.10 10.10 9.30 CE3AA030 27,800 NONE 10.00 10.10 10.10 9.15 CE3AA036 28,600 NONE 10.00 10.10 10.10 9.25 CF5AA036 28,800 NONE 10.00 10.10 10.10 9.30 CK3BA030 28,000 NONE 10.00 10.10 10.10 9.10 CK3BA036 29,000 NONE 10.00 10.10 10.10 9.35 CK5A/CK5BA030 28,000 NONE 10.00 10.10 10.10 9.10 CK5A/CK5BA036 29,000 NONE 10.00 10.10 10.10 9.35 CK5A/CK5BNO36 27,000 NONE 10.00 10.10 10.10 9.35 CK5A/CK5BT036 29,000 NONE 10.00 10.10 10.10 9.35 CK5A/CK5BW030 28,000 NONE 10.00 10.10 10.10 9.10 CK5A/CK5BW036 29,000 NONE 10.00 10.10 10.10 9.35 F(A,BAN(F,C)030 27,600 TDR 10.00 - 10.00 9.20 F(A,B AN(F,C)036 28,200 TDR 10.00 - 10.00 9.10 F BNF030 27,600 TDR & TXV 10.00 - - 9.20 FC4BNF036 28,200 TDR & TXV 10.00 - - 9.10 FF1(B,C,D)NA030 28,000 TDR 10.00 - 10.00 9.10 FG3AAA036 28,000 NONE 10.00 10.10 10.10 9.20 FK4CNFOO1 29,000 TDR & TXV 11.00 - - 9.95 FK4CNFOO2 29,200 TDR & TXV 11.00 - - 10.00 FK4CNF003 29,400 TDR & TXV 11.50 - - 10.30 FK4CNFOO5 29,600 TDR & TXV 11.50 - - 10.55 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA030 28,000 TDR 10.50 - 10.50 9.70 CC5A/CD5AA036 29,000 TDR 11.00 - 11.00 10.00 CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.70 CK3BA030 28,000 TDR 10.50 - 10.50 9.70 CK3BA036 29,000 TDR 11.00 - 11.00 10.05 CK5A/CK5BA030 28,000 TDR 10.50 - 10.50 9.70 CK5A/CK5BA036 29,000 TDR 11.00 - 11.00 10.05 CK5A/CK5BNO36 27,000 TDR 11.00 - 11.00 9.90 CK5A/CK5BT036 29,000 TDR 11.00 - 11.00 10.05 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.70 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE 030-A CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.80 CD5AW036 29,000 TDR 11.00 - 11.00 10.15 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.85 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 1020 COILS + 355MAVO42040 VARIABLE -SPEED FURNACE CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.50 CD5AW036 29,000 TDR 11.00 - 11.00 9.85 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.50 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 9.85 • COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CC5A/CD5AA036 29,000 TDR 11.00 - 11.00 9.80 CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.50 CK3BA030 28,000 TDR 10.50 - 10.50 9.50 CK3BA036 29,000 TDR 11.00 - 11.00 9.85 CK5A/CK5BA036 29,000 TDR 11.00 - 11.00 9.85 CK5A/CK5BT036 29,000 TDR 11.00 - 11.00 9.85 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 _ 9.50 COILS + 355MAVO42080 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.55 CD5AW036 29,000 TDR 11.00 - 11.00 9.90 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.60 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 9.95 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.45 CD5AW036 29,000 TDR 11.00 - 11.00 9.80 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.50 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 9.85 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,000 TDR 10.50 - 10.50 9.75 CD5AW036 29,000 TDR 11.00 - 11.00 10.10 CK5A/CK5BW030 28,000 TDR 10.50 - 10.50 9.80 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 10.10 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CD5AW036 29,000 TDR 11.00 - 11.00 10.05 CK5A/CK5BW036 29,000 TDR 11.00 - 11.00 10.05 CC5A/CD5AW030' 28,000 NONE - 10.00 10.00 8.80 CC5A/CD5AA036 29,000 NONE - 10.00 10.00 9.00 CC5A/CD5AW036 29,000 NONE - 10.00 10.00 9.00 030 -E CE3AA030 28,000 NONE - 10.00 10.00 8.90 CE3AA036 28,600 NONE - 10.00 10.00 8.95 CF5AA036 28,600 NONE - 10.00 10.00 9.00 CK3BA030 28,000 NONE - 10.00 10.00 8.85 CK3BA036 29,000 NONE - 10.00 10.00 9.05 See notes on page 18. -10- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CK5A/CK5BA030 28,000 NONE - 10.00 10.00 8.85 CK5A/CK5BA036 29,000 NONE - 10.00 10.00 9.05 CK5A/CK5BT036 29,000 NONE - 10.00 10.00 9.05 CK5A/CK5BW030 28,000 NONE - 10.00 10.00 8.85 CK5A/CK5BW036 29,000 NONE - 10.00 10.00 9.05 F(A,B)44AN(F,C)036 28,400 TDR 10.00 - 10.00 8.85 FC4BN 030 28,000 TDR &TXV 10.00 - - 8.95 FC4BNF036 28,400 TDR &TXV 10.00 - - 8.85 FF1DNA030 28,000 TDR 10.00 - 10.00 8.90 FG3AAA036 28,400 NONE 10.00 - 10.00 8.90 FK4CNFO01 28,400 TDR &TXV 11.00 - - 9.60 FK4CNFOO2 28,800 TDR &TXV 11.00 - - 9.65 FK4CNF003 29,000 TDR &TXV 11.00 - - 9.90 FK4CNFOO5 29,600 TDR &TXV 11.00 - - 10.10 COILS + 333(B,J,)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA030 27,600 TDR 10.50 - 10.50 9.35 CC5A/CD5AA036 28,600 TDR 10.50 - 10.50 9.60 CC5A/CD5AW030 27,600 TDR 10.50 - 10.50 9.35 CE3AA030 27,600 TDR 10.50 - 10.50 9.45 CE3AA036 28,000 TDR 10.50 - 10.50 9.45 CK3BA030 27,600 TDR 10.50 - 10.50 9.40 CK3BA036 28,600 TDR 10.50 - 10.50 9.65 CK5A/CK5BA030 27,600 TDR 10.50 - 10.50 9.40 CK5A/CK5BA036 29,200 TDR 10.50 - 10.50 9.65 CK5A/CK5BT036 28,600 TDR 10.50 - 10.50 9.65 CK5A/CK5BW030 27,600 TDR 10.50 - 10.50 9.40 COILS + 333(B,J,)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AW030 27,600 TDR 10.50 - 10.50 9.50 CC5A/CD5AW036 28,600 TDR 10.50 - 10.50 9.75 CE3AA030 27,600 TDR 10.50 - 10.50 9.60 CE3AA036 28,000 TDR 10.50 - 10.50 9.60 CK3BA030 27,600 TDR 10.50 - 10.50 9.50 CK3BA036 28,600 TDR 10.50 - 10.50 9.80 030 -E CK5A/CK5BW036 28,600 TDR 10.50 - 10.50 9.80 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CC5A/CD5AA036 28,600 TDR 10.50 - 10.50 9.50 CC5A/CD5AW030 27,600 TDR 10.50 - 10.50 9.25 CE3AA030 27,600 TDR 10.50 - 10.50 9.35 CE3AA036 28,000 TDR 10.50 - 10.50 9.40 CK3BA036 28,600 TDR 10.50 - 10.50 9.50 CK5A/CK5BA036 28,600 TDR 10.50 - 10.50 9.50 CK5A/CK5BT036 28,600 TDR 10.50 - 10.50 9.50 CK5A/CK5BW030 27,600 TDR 10.50 - 10.50 920 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AW030 27,600 TDR 10.50 - 10.50 9.35 CC5A/CD5AW036 28,600 TDR 10.50 - 10.50 9.60 CE3AA030 27,600 TDR 10.50 - 10.50 9.45 CE3AA036 28,000 TDR 10.50 - 10.50 9.50 CK3BA036 28,600 TDR 10.50 - 10.50 9.60 CK5A/CK5BW030 27,600 TDR 10.50 - 10.50 9.25 CK5A/CK5BW036 28,600 TDR 10.50 - 10.50 9.60 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA036 28,600 TDR 10.50 - 10.50 9.60 CC5A/CD5AW030 27,600 TDR 10.50 - 10.50 9.35 CC5A/CD5AW036 28,600 TDR 10.50 - 10.50 9.60 CE3AA030 27,600 TDR 10.50 - 10.50 9.45 CE3AA036 28,000 TDR 10.50 - 10.50 9.50 CK3BA030 27,600 TDR 10.50 - 10.50 9.45 CK3BA036 28,600 TDR 10.50 - 10.50 9.75 CK5A/CK5BA036 28,600 TDR 10.50 - 10.50 9.75 CK5A/CK5BT036 28,600 TDR 10.50 - 10.50 9.75 CK5A/CK5BW030 27,600 TDR 10.50 - 10.50 9.45 CK5A/CK5BW036 29,800 TDR 10.50 - 10.50 9.75 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AW036 28,600 TDR 10.50 - 10.50 9.60 CE3AA030 27,600 TDR 10.50 - 10.50 9.45 CE3AA036 28,000 TDR 10.50 - 10.50 9.50 CK5A/CK5BW036 28,600 TDR 10.50 - 10.50 9.70 CC5A/CD5AA036' 33,800 NONE 10.00 10.20 10.20 9.20 CC5A/CD5AA042 33,800 NONE 10.00 10.20 10.20 9.20 CC5A/CD5AW042 33,800 NONE 10.00 10.20 10.20 9.15 CD5AW036 33,800 NONE 10.00 10.20 10.20 9.20 036 B, E CE3AA036 33,400 NONE 10.00 10.20 10.20 9.10 CE3AA042 33,600 NONE 10.00 10.20 10.20 9.25 CF5AA036 33,600 NONE 10.00 10.20 10.20 9.15 CK3BA036 33,800 NONE 10.00 10.20 10.20 9.20 CK3BA042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BA036 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BA042 33,800 NONE 10.00 10.20 10.20 9.20 See notes on page 18. -11- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXVt EERA CK5A/CK5BNO36 31,400 NONE 10.00 10.20 10.20 9.30 CK5A/CK5BN042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BT036 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BT042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BW036 33,800 NONE 10.00 10.20 10.20 9.20 F (A,B)4AN(F,B,C )042 33,800 TDR 10.00 - 10.00 9.15 F(A,6B)4AN(F,C) 36 33,000 TDR 10.00 - 10.00 8.90 FC4BN(F,B)042 33,800 TDR & TXV 10.00 - - 9.15 FC4BNB054 34,800 TDR & TXV 10.50 - - 9.70 FC4BNF036 33,000 TDR & TXV 10.00 - - 8.90 FG3AAA036 32,600 NONE - 10.00 10.00 9.05 FK4CNB006 35,200 TDR & TXV 11.00 - - 10.55 FK4CNFOO1 33,000 TDR &TXV 10.00 - - 9.60 FK4CNFOO2 33,000 TDR &TXV 10.00 - - 9.60 FK4CNF003 33,600 TDR & TXV 10.50 - - 10.05 FK4CNFOO5 35,000 TDR & TXV 11.00 - - 10.35 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA036 33,400 TDR 10.50 - 10.50 9.65 CK3BA036 33,400 TDR 10.50 - 10.50 9.65 CK5A/CK5BA036 33,400 TDR 10.50 - 10.50 9.65 CK5A/CK5BNO36 31,400 TDR 10.50 - 10.50 9.55 CK5A/CK5BT036 33,400 TDR 10.50 - 10.50 9.65 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.85 CC5A/CD5AW042 33,400 TDR 10.80 - 10.80 9.80 CD5AW036 33,400 TDR 10.50 - 10.50 9.80 CK3BA042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.80 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 10.05 CD5AW036 33,400 TDR 10.50 - 10.50 10.00 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 10.10 CK5A/CK5B7042 33,400 TDR 10.80 - 10.80 10.10 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 10.05 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 10.00 036 -B, E CD5AW036 33,400 TDR 10.50 - 10.50 9.95 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 10.00 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 10.00 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.95 COLS + 355MAVO42040 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.75 CD5AW036 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 9.80 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 9.80 COLS + 355MAVO42060 VARIABLE -SPEED FURNACE CC5A/CD5AA036 33,400 TDR 10.50 - 10.50 9.70 CK3BA036 33,400 TDR 10.50 - 10.50 9.70 CK3BA042 33,400 TDR 10.80 - 10.80 9.75 CK5A/CK5BA036 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BT036 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.75 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.80 CC5A/CD5AW042 33,400 TDR 10.80 - 10.80 9.75 CD5AW036 33,400 TDR 10.50 - 10.50 9.75 CK3BA042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 9.85 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.80 COILS + 355MAV060080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.75 CC5A/CD5AW042 33,400 TDR 10.80 - 10.80 9.70 CD5AW036 33,400 TDR 10.50 - 10.50 9.65 CK3BA042 33,400 TDR 10.80 - 10.80 9.75 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 9.75 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 9.75 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.70 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.95 CC5A/CD5AW042 33,400 TDR 10.80 - 10.80 9.90 CD5AW036 33,400 TDR 10.50 - 10.50 9.90 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 10.00 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 10.00 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.95 See notes on page 18. -12- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE -SERIES MODEL BTUH MENT RATING TDRt TXVt EERA COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.80 - 10.80 9.90 036 -8, E CD5AW036 33,400 TDR 10.50 - 10.50 9.85 CK5A/CK5BA042 33,400 TDR 10.80 - 10.80 9.95 CK5A/CK5BT042 33,400 TDR 10.80 - 10.80 9.95 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.90 CC5A/CD5AA036' 33,800 NONE - 10.00 10.00 9.00 CC5A/CD5AA042 33,800 NONE - 10.00 10.00 9.00 CC5A/CD5AW036 33,800 NONE - 10.00 10.00 9.00 CC5A/CD5AW042 33,800 NONE - 10.00 10.00 8.95 CE3AA036 33,400 NONE - 10.00 10.00 8.90 CE3AA042 33,800 NONE - 10.00 10.00 9.05 CF5AA036 33,800 NONE - 10.00 10.00 8.95 CK3BA036 33,800 NONE - 10.00 10.00 9.00 CK3BA042 33,800 NONE - 10.00 10.00 9.00 CK5A/CK5BA036 33,800 NONE - 10.00 10.00 9.00 CK5A/CK5BA042 33,800 NONE - 10.00 10.00 9.00 CK5A/CK5BT036 33,800 NONE - 10.00 10.00 9.00 CK5A/CK5BT042 33,800 NONE - 10.00 10.00 9.00 CK5A/CK5BW036 33,800 NONE - 10.00 10.00 9.00 F(A,B )4AN(F,B,C )042 33,800 TDR 10.00 - 10.00 8.95 F(A,B)4AN(F,C)036 33,400 TDR 10.00 - 10.00 8.75 C4BN(F,B)042 33,800 TDR &TXV 10.00 8.95 FC4BNF036 33,400 TDR &TXV 10.00 - - 8.75 FG3AAA036 33,000 NONE 10.00 - 10.00 8.85 FK4CNB006 35,400 TDR &TXV 11.00 - - 10.25 FK4CNFOO1 33,000 TDR &TXV 10.50 - - 9.40 FK4CNFOO2 33,000 TDR &TXV 10.50 - - 9.35 FK4CNF003 33,600 TDR &TXV 11.00 - - 9.75 FK4CNFOO5 35,000 TDR &TXV 11.00 - - 10.05 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA036 33,400 TDR 10.50 - 10.50 9.40 CE3AA036 33,000 TDR 10.50 - 10.50 9.30 CE3AA042 33,400 TDR 10.50 - 10.50 9.50 CK3BA036 33,400 TDR 10.50 - 10.50 9.45 CK5A/CK5BA036 33,400 TDR 10.50 - 10.50 9.45 CK5A/CK5BT036 33,400 TDR 10.50 - 10.50 9.45 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.45 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.50 - 10.50 9.70 CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 33,400 TDR 10.50 - 10.50 9.65 CE3AA036 33,000 TDR 10.50 - 10.50 9.50 036 F CE3AA042 33,400 TDR 10.50 - 10.50 9.65 CK3BA036 33,400 TDR 10.50 - 10.50 9.55 CK3BA042 33,400 TDR 10.50 - 10.50 9.60 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.60 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.60 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.55 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.70 CC5A/CD5AW042 33,400 TDR 10.50 - 10.50 9.70 CE3AA036 33,000 TDR 10.50 - 10.50 9.65 CE3AA042 33,400 TDR 10.50 - 10.50 9.80 CK3BA042 33,400 TDR 10.50 - 10.50 9.80 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.80 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.80 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.80 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.60 CC5A/CD5AW042 33,400 TDR 10.50 - 10.50 9.65 CE3AA036 33,000 TDR 10.50 - 10.50 9.50 CE3AA042 33,400 TDR 10.50 - 10.50 9.70 CK3BA042 33,400 TDR 10.50 - 10.50 9.75 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.75 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.75 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.70 COILS + 355MAVO42060 VARIABLE - SPEED FURNACE CC5A/CD5AA036 33,400 TDR 10.50 - 10.50 9.45 CE3AA036 32,800 TDR 10.50 - 10.50 9.35 CE3AA042 33,400 TDR 10.50 - 10.50 9.55 CK3BA036 33,400 TDR 10.50 - 10.50 9.45 CK5A/CK5BA036 33,400 TDR 10.50 - 10.50 9.45 CK5A/CK5BT036 33,400 TDR 10.50 - 10.50 9.45 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.50 - 10.50 9.60 CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 33,200 TDR 10.50 - 10.50 9.55 CE3AA036 32,800 TDR 10.50 - 10.50 9.45 CE3AA042 32,400 TDR 10.50 - 10.50 9.65 CK3BA042 33,400 TDR 10.50 - 10.50 9.60 See notes on page 18. -13- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE - STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXVt EERA CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.60 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.60 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.55 COILS + 355MAV060080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.50 - 10.50 9.50 CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 33,200 TDR 10.50 - 10.50 9.60 CE3AA036 32,800 TDR 10.50 - 10.50 9.45 CE3AA042 33,400 TDR 10.50 - 10.50 9.70 CK3BA042 33,400 TDR 10.50 - 10.50 9.50 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.50 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.50 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 . 9.45 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.50 - 10.50 9.65 036-F CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 33,200 TDR 10.50 - 10.50 9.60 CE3AA036 32,800 TDR 10.50 - 10.50 9.45 CE3AA042 33,400 TDR 10.50 - 10.50 9.70 CK3BA042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.70 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA042 33,400 TDR 10.50 - 10.50 9.65 CC5A/CD5AW036 33,400 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 33,200 TDR 10.50 - 10.50 9.60 CE3AA036 33,000 TDR 10.50 - 10.50 9.45 CE3AA042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BA042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BT042 33,400 TDR 10.50 - 10.50 9.70 CK5A/CK5BW036 33,400 TDR 10.50 - 10.50 9.65 CC5A/CD5AA042* 40,000 NONE 10.00 10.10 10.10 9.00 CC5A/CD5AC048 39,500 NONE 10.00 10.10 10.10 8.95 CC5A/CD5AW042 40,000 NONE 10.00 10.10 10.10 9.00 CC5A/CD5AW048 40,000 NONE 10.00 10.10 10.10 9.00 CD5AA048 40,000 NONE 10.00 10.10 10.10 9.00 CE3AA042 39,500 NONE 10.00 10.10 10.10 8.95 CE3AA048 40,500 NONE 10.00 10.10 10.10 9.10 CK3BA042 40,000 NONE 10.00 10.10 10.10 9.00 CK3BA048 40,000 NONE 10.00 10.10 10.10 9.00 CK5A/CK5BA042 40,000 NONE 10.00 10.10 10.10 9.05 CK5A/CK5BA048 40,000 NONE 10.00 10.10 10.10 9.00 CK5A/CK5BN042 39,000 NONE 10.00 10.10 10.10 9.05 CK5A/CK5BNO48 39,000 NONE 10.00 10.10 10.10 9.00 CK5A/CK5BW048 40,000 NONE 10.00 10.10 10.10 9.00 F(A,B)44AN(F,B)048 4� 000 TDR 10.10 - 10.10 9.00 FC4BN(F,B)042 40,000 TDR &TXV 10.00 - - 8.90 FC4BN(F,B)048 41,000 TDR &TXV 10.10 - - 9.00 FC4BNB054 41,500 TDR &TXV 10.50 - - 8.90 FG3AAA048 40,000 NONE 10.00 10.10 10.10 9.00 FK4CNF003 40,000 TDR &TXV 10.50 - - 9.60 FK4CNFOO5 41,000 TDR &TXV 11.00 - - 9.95 FK4CNFOO6 41,500 TDR &TXV 11.00 - - _ 10.15 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.45 042 -B CC5A/CD5AC048 40,000 TDR 10.70 - 10.70 9.45 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.55 CC5A/CD5AW048 40,000 TDR 10.70 - 10.70 9.45 CD5AA048 40,000 TDR 10.70 - 10.70 9.45 CE3AA042 40,000 TDR 10.50 - 10.50 9.55 CE3AA048 40,000 TDR 10.70 - 10.70 9.45 CK3BA042 40,000 TDR 10.50 - 10.50 9.45 CK3BA048 40,000 TDR 10.70 - 10.70 9.45 CK5A/CK5BA042 40,000 TOR 10.50 - 10.50 9.55 CK5A/CK5BA048 40,000 TDR 10.70 - 10.70 9.45 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.60 CC5A/CD5AC048 40,000 TDR 10.70 - 10.70 9.60 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.60 CC5A/CD5AW048 40,000 TDR 10.70 - 10.70 9.60 CD5AA048 40,000 TDR 10.70 - 10.70 9.60 CE3AA042 40,000 TDR 10.50 - 10.50 9.45 CE3AA048 40,000 TDR 10.70 - 10.70 9.45 CK3BA042 40,000 TDR 10.50 - 10.50 9.45 CK3BA048 40,000 TDR 10.70 - 10.70 9.60 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.45 CK5A/CK5BW048 40,000 TDR 10.70 - 10.70 9.45 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.50 CC5A/CD5AC048 40,000 TDR 10.70 - 10.70 9.55 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.50 See notes on page 18. -14- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXVt EERA CC5A/CD5AW048 40,000 TDR 10.70 - 10.70 9.55 CD5AA048 40,000 TDR 10.70 - 10.70 9.55 CE3AA042 40,000 TDR 10.50 - 10.50 9.55 CE3AA048 40,000 TDR 10.70 - 10.70 9.55 CK3BA042 40,000 TDR 10.50 - 10.50 9.50 CK3BA048 40,000 TDR 10.70 - 10.70 9.50 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.50 CK5A/CK5BW048 40,000 TDR 10.70 - 10.70 9.55 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.30 CC5A/CD5AC048 40,000 TDR 10.70 - 10.70 9.45 CK3BA042 40,000 TDR 10.50 - 10.50 9.30 CK3BA048 40,000 TDR 10.70 - 10.70 9.45 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.30 CK5A/CK5BA048 40,000 TDR 10.70 - 10.70 9.45 042-B COILS + 35514AV060080 VARIABLE -SPEED FURNACE CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.30 CK5A/CK5BA048 40,000 TDR 10.70 - 10.70 9.45 CK3BA042 40,000 TDR 10.50 - 10.50 9.30 CK3BA048 40,000 TDR 10.70 - 10.70 9.45 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AC048 40,000 TDR 10.70 - 10.70 9.45 CK3BA042 40,000 TDR 10.50 - 10.50 9.45 CK3BA048 40,000 TDR 10.70 - 10.70 9.45 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.45 CK5A/CK5BA048 40,000 TDR 10.70 - 10.70 9.45 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CK3BA042 40,000 TDR 10.50 - 10.50 9.45 CK3BA048 40,000 TDR 10.70 - 10.70 9.45 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.45 CK5A/CK5BW048 40,000 TDR 10.70 - 10.70 9.45 CC5A/CD5AA042* 40,500 NONE 10.00 10.20 10.20 9.05 CC5A/CD5AA048 41,000 NONE 10.00 10.20 1020 9.05 CC5A/CD5AC048 40,500 NONE 10.00 10.20 10.20 8.95 CC5A/CD5AW042 40,500 NONE 10.00 10.20 10.20 9.00 CC5A/CD5AW048 41,000 NONE 10.00 10.20 10.20 9.05 CE3AA042 40,500 NONE 10.00 10.20 10.20 9.10 CE3AA048 41,000 NONE 10.00 10.20 10.20 9.10 CF5AA048 41,000 NONE 10.00 10.20 10.20 9.05 CK3BA042 40,500 NONE 10.00 10.20 10.20 9.05 CK3BA048 41,000 NONE 10.00 10.20 10.20 9.10 CK5A/CK5BA042 40,500 NONE 10.00 10.20 10.20 9.05 CK5A/CK5BA048 41,000 NONE 10.00 10.20 10.20 9.10 CK5A/CK5BT042 40,500 NONE 10.00 10.20 10.20 9.05 CK5A/CK5BT048 41,000 NONE 10.00 10.20 10.20 9.10 CK5A/CK5BW048 41,000 NONE 10.00 10.20 10.20 9.10 F(A 411, TDR 10.00 - 10.00 9.05 FC4BN( B)042 40,500 TDR &TXV 10.00 - - 8.95 FC4BN(FB)048 41,000 TDR &TXV 10.00 - - 9.05 FC4BNB054 41,500 TDR &TXV 10.50 - - 9.50 FG3AAA048 40,500 NONE 10.00 - 10.00 9.00 FK4CNB006 42,000 TDR &TXV 11.00 - - 10.15 FK4CNF003 40,500 TDR &TXV 11.00 - - 9.60 FK4CNFOO5 41,500 TDR &TXV 11.00 - - 9.95 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE 042-E CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AA048 40,500 TDR 10.50 - 10.50 9.55 CC5A/CD5AC048 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.40 CE3AA042 40,000 TDR 10.50 - 10.50 9.50 CE3AA048 40,500 TDR 10.50 - 10.50 9.55 CK3BA042 40,000 TDR 10.50 - 10.50 9.45 CK3BA048 40,500 TDR 10.50 - 10.50 9.55 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.45 CK5A/CK5BA048 40,500 TDR 10.50 - 10.50 9.55 CK5A/CK5BT042 40,000 TDR 10.50 - 10.50 9.45 CK5A/CK5BT048 40,500 TDR 10.50 - 10.50 9.55 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.55 CC5A/CD5AW048 40,500 TDR 10.50 - 10.50 9.70 CE3AA042 40,000 TDR 10.50 - 10.50 9.70 CE3AA048 40,500 TDR 10.50 - 10.50 9.70 CK3BA042 40,000 TDR 10.50 - 10.50 9.65 CK3BA048 40,500 TDR 10.50 - 10.50 9.75 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.65 CK5A/CK5BT042 40,000 TDR 10.50 - 10.50 9.65 CK5A/CK5BW048 40,500 TDR 10.50 - 10.50 9.75 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AW048 40,500 TDR 10.50 - 10.50 9.60 See notes on page 18. -1 5- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE - SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CE3AA042 40,000 TDR 10.50 - 10.50 9.55 CE3AA048 40,500 TDR 10.50 - 10.50 9.60 CK3BA042 40,000 TDR 10.50 - 10.50 9.65 CK3BA048 40,500 TDR 10.50 - 10.50 9.75 CK5A/CK5BA042 40,000 TDR 10.50 - 10.50 9.65 CK5A/CK5BT042 40,000 TDR 10.50 - 10.50 9.65 CK5A/CK5BW048 40,500 TDR 10.50 - 10.50 9.75 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AA048 40,500 TDR 10.50 - 10.50 9.55 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.40 CE3AA042 40,000 TDR 10.50 - 10.50 9.45 CE3AA048 40,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BA048 40,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BT048 40,500 TDR 10.50 - 10.50 9.50 COILS + 355MAV060080 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.50 CC5A/CD5AA048 40,500 TDR 10.50 - 10.50 9.60 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.45 CE3AA042 40,000 TDR 10.50 - 10.50 9.50 042 -E CE3AA048 40,500 TDR 10.50 - 10.50 9.55 CK5A/CK5BA048 40,500 TDR 10.50 - 10.50 9.40 CK5A/CK5BT048 40,500 TDR 10.50 - _ 10.50 9.40 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.50 CC5A/CD5AA048 40,500 TDR 10.50 - 10.50 9.60 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.45 CE3AA042 40,000 TDR 10.50 - 10.50 9.50 CE3AA048 40,500 TDR 10.50 - 10.50 9.55 CK3BA048 40,500 TDR 10.50 - 10.50 9.65 CK5A/CK5BA048 40,500 TDR 10.50 - 10.50 9.65 CK5A/CK5BT048 40,500 TDR 10.50 - 10.50 9.65 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 - 10.50 9.50 CC5A/CD5AW042 40,000 TDR 10.50 - 10.50 9.45 CC5A/CD5AW048 40,500 TDR 10.50 - 10.50 9.60 CE3AA042 40,000 TDR 10.50 - 10.50 9.50 CE3AA048 40,500 TDR 10.50 - 10.50 9.55 CK3BA048 40,500 TDR 10.50 - 10.50 9.65 CK5A/CK5BA048 40,500 TDR 10.50 - 10.50 9.65 CK5A/CK5BT048 40,500 TDR 10.50 - 10.50 9.65 CK5A/CK5BW048 40,500 TDR 10.50 - 10.50 9.65 CC5A/CD5AA048* 44,000 NONE 10.00 10.2 10.20 8.95 CC5A/CD5AA060 44,000 NONE 10.00 10.2 10.20 8.95 CC5A/CD5AC048 43,000 NONE - 10 10.00 8.85 CC5A/CD5AW048 44,000 NONE 10.00 10.2 10.20 8.95 CC5A/CD5AW060 45,000 NONE 10.00 10.5 10.50 9.15 CE3AA048 44,000 NONE 10.00 10.2 10.20 9.05 CE3AA060 45,000 NONE 10.00 10.5 10.50 9.15 CF5AA048 44,000 NONE 10.00 10.2 10.20 9.00 CK3BA048 44,000 NONE 10.00 10.2 10.20 9.00 CK3BA060 45,000 NONE 10.00 10.5 10.50 915 CK5A/CK5BA048 44,000 NONE 10.00 10.2 10.20 9.00 CK5A/CK5BA060 45,000 NONE 10.00 10.5 10.50 9.15 CK5A/CK5BT048 44,000 NONE 10.00 10.2 10.20 9.00 CK5A/CK5BT060 45,000 NONE 10.00 10.5 10.50 9.15 CK5A/CK5BW048 44,000 NONE 10.00 10.2 1020 9.00 CK5A/CK5BX060 45,000 NONE 10.00 10.5 10.50 9.25 F(A,B)4AN(F,B,C)048 44,500 TDR 10.00 - 10.00 8.90 F(A,B)4AN(F,B,C)060 45,500 TDR 10.00 - 10.00 8.95 FB4ANB070 46,000 TDR 10.50 - 10.50 9.25 047 -A FC4BN(F,B)048 44,500 TDR &TXV 10.00 - - 8.90 FC4BN(F,B)060 45,500 TDR &TXV 10.00 - - 8.95 FC4BNB054 46,000 TDR &TXV 10.50 - - 9.25 FC4BNB070 46,000 TDR &TXV 10.50 - - 9.25 FG3AAA048 43,000 NONE - 10.00 10.00 8.90 FG3AAA060 44,000 NONE - 10.00 10.00 9.10 FK4CNB006 46,500 TDR &TXV 11.50 - - 10.05 FK4CNFOO5 45,500 TDR &TXV 11.00 - _ - 9.75 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AA048 43,500 TDR 10.50 - 10.50 9.25 CC5A/CD5AC048 43,000 TDR 10.50 - 10.50 9.15 CE3AA048 43,500 TDR 10.50 - 10.50 9.25 CE3AA060 44,500 TDR 10.50 - 10.50 9.50 CK3BA048 43,500 TDR 10.50 - 10.50 9.20 CK5A/CK5BA048 43,500 TDR 10.50 - 10.50 9.20 CK5A/CK5BT048 43,500 TDR 10.50 - 10.50 9.20 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA060 ( 43,500 ( TDR 1 10.50 1 - ( 10.50 1 9.50 See notes on page 18. -16- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE - STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CC5A/CD5AW048 43,500 TDR 10.50 - 10.50 9.50 CC5A/CD5AW060 44,500 TDR 10.50 - 10.50 9.70 CE3AA048 43,500 TDR 10.50 - 10.50 9.50 CE3AA060 44,500 TDR 10.50 - 10.50 9.75 CK3BA048 43,500 TDR 10.50 - 10.50 9.55 CK3BA060 44,500 TDR 10.50 - 10.50 9.80 CK5A/CK5BA060 44,500 TDR 10.50 - 10.50 9.80 CK5A/CK5BT060 44,500 TDR 10.50 - 10.50 9.80 CK5A/CK5BW048 43,500 TDR 10.50 - 10.50 9.55 CK5A/CK5BX060 45,000 TDR 10.50 - 10.50 9.95 COILS + 333(B,J)AVO60120 VARIABLE -SPEED FURNACE CC5A/CD5AA060 43,500 TDR 10.50 - 10.50 9.40 CC5A/CD5AW048 43,500 TDR 10.50 - 10.50 9.40 CC5A/CD5AW060 44,500 TDR 10.50 - 10.50 9.60 CE3AA048 43,500 TDR 10.50 - 10.50 9.40 CE3AA060 44,500 TDR 10.50 - 10.50 9.60 CK3BA048 43,500 TDR 10.50 - 10.50 9.50 CK3BA060 44,500 TDR 10.50 - 10.50 9.70 CK5A/CK5BA060 44,500 TDR 10.50 - 10.50 9.70 CK5A/CK5BT060 44,500 TDR 10.50 - 10.50 9.70 CK5A/CK5BW048 43,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BX060 45,000 TDR 10.50 - 10.50 9.85 047 - A COILS + 355MA /060080 VARIABLE -SPEED FURNACE CC5A/CD5AA060 43,500 TDR 10.50 - 10.50 9.30 CC5A/CD5AW060 44,500 TDR 10.50 - 10.50 9.50 CE3AA060 44,500 TDR 10.50 - 10.50 9.50 CC5A/CD5AA060 43,500 TDR 10.50 - 10.50 9.30 CC5A/CD5AW060 44,500 TDR 10.50 - 10.50 9.50 CE3AA060 44,500 TDR 10.50 - 10.50 9.50 CK3BA060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BA060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BT060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BX060 45,000 TDR 10.50 - 10.50 9.65 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA060 43,500 TDR 10.50 - 10.50 9.30 CC5A/CD5AW060 44,500 TDR 10.50 - 10.50 9.50 CE3AA060 44,500 TDR 10.50 - 10.50 9.50 CK3BA048 43,500 TDR 10.50 - 10.50 9.35 CK3BA060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BA048 43,500 TDR 10.50 - 10.50 9.35 CK5A/CK5BA060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BT048 43,500 TDR 10.50 - 10.50 9.35 CK5A/CK5BT060 44,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BW048 43,500 TDR 10.50 - 10.50 9.35 CK5A/CK5BX060 45,000 TDR 10.50 - 10.50 9.65 CC5A/CD5AA048* 46,000 NONE 10.00 10.20 10.20 8.95 CC5A/CD5AA060 46,500 NONE 10.00 10.20 10.20 9.00 CC5A/CD5AC048 45,000 NONE - 10.00 10.00 8.90 CC5A/CD5AW048 46,000 NONE 10.00 10.20 10.20 8.95 CC5A/CD5AW060 47,000 NONE 10.00 10.50 10.50 9.15 CE3AA048 46,000 NONE 10.00 10.20 10.20 9.05 CE3AA060 47,000 NONE 10.00 10.50 10.50 9.20 CF5AA048 46,000 NONE 10.00 10.20 10.20 9.00 CK3BA048 46,000 NONE 10.00 10.20 10.20 9.00 CK3BA060 47,000 NONE 10.00 10.50 10.50 9.15 CK5A/CK5BA048 46,000 NONE 10.00 10.20 10.20 9.00 CK5A/CK5BA060 47,000 NONE 10.00 10.50 10.50 9.15 CK5A/CK5BT048 46,000 NONE 10.00 10.20 10.20 9.00 CK5A/CK5BT060 47,000 NONE 10.00 10.50 10.50 9.15 CK5A/CK5BW048 46,000 NONE 10.00 10.20 1020 9.00 CK5A/CK5BX060 47,000 NONE 10.00 10.50 10.50 9.30 F(A,B)44AN(FB,C; 60 48, TDR 10.00 - 10.00 9.00 FB4ANB070 49,000 TDR 10.50 - 10.50 9.25 048 -F FC4BN F,B 048 46,500 TDR &TXV 10.00 - - 8.95 FC4BN(F,B)060 48,000 TDR &TXV 10.00 - - 9.00 FC4BNB054 48,500 TDR &TXV 10.50 - - 9.30 FC4BNB070 49,000 TDR &TXV 10.50 - - 9.25 FG3AAA048 46,000 NONE - 10.00 10.00 8.90 FG3AAA060 47,000 NONE - 10.00 10.00 9.10 FK4CNB006 48,500 TDR &TXV 11.50 - - 10.00 FK4CNFOO5 47,500 TDR &TXV 11.00 - - 9.70 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AA048 45,500 TDR 10.50 - 10.50 925 CC5A/CD5AC048 45,000 TDR 10.50 - 10.50 9.15 CE3AA048 45,500 TDR 10.50 - 10.50 9.25 CE3AA060 46,500 TDR 10.50 - 10.50 9.50 CK3BA048 45,500 TDR 10.50 - 10.50 9.15 CK5A/CK5BA048 45,500 TDR 10.50 - 10.50 9.15 CK5A/CK5BT048 45,500 TDR 10.50 - 10.50 9.15 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA060 46,000 TDR 10.50 - 10.50 9.50 CC5A/CD5AW048 45,500 TDR 10.50 - 10.50 9.45 CC5A/CD5AW060 46,500 TDR 10.50 - 10.50 9.65 See notes on page 18. -1 7- COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE - STANDARD ACCESSORY ACCESSORY SIZE- SERIES MODEL BTUH MENT RATING TDRt TXV$ EERA CE3AA048 45,500 TDR 10.50 - 10.50 9.45 CE3AA060 46,500 TDR 10.50 - 10.50 9.70 CK3BA048 45,500 TDR 10.50 - 10.50 9.50 CK3BA060 46,500 TDR 11.00 - 11.00 9.75 CK5A/CK5BA060 46,500 TDR 11.00 - 11.00 9.75 CK5A/CK5BT060 46,500 TDR 11.00 - 11.00 9.75 CK5A/CK5BW048 45,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BX060 47,000 TDR 11.00 - 11.00 9.90 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA060 46,000 TDR 10.50 - 10.50 9.35 CC5A/CD5AW048 45,500 TDR 10.50 - 10.50 9.35 CC5A/CD5AW060 46,500 TDR 10.50 - 10.50 9.55 CE3AA048 45,500 TDR 10.50 - 10.50 9.35 CE3AA060 46,500 TDR 10.50 - 10.50 9.60 CK3BA048 45,500 TDR 10.50 - 10.50 9.45 CK3BA060 46,500 TDR 11.00 - 11.00 9.65 CK5A/CK5BA060 46,500 TDR 11.00 - 11.00 9.65 CK5A/CK5BTO60 46,500 TDR 11.00 - 11.00 9.65 CK5A/CK5BW048 45,500 TDR 10.50 - 10.50 9.45 CK5A/CK5BX060 47,000 TDR 11.00 - 11.00 9.80 COILS + 355MAV060080 VARIABLE -SPEED FURNACE 048_F CC5A/CD5AA060 45,500 TDR 10.50 - 10.50 9.25 CC5A/CD5AW060 46,500 TDR 10.50 - 10.50 9.50 CE3AA060 46,500 TDR 10.50 - 10.50 9.50 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA060 45,500 TDR 10.50 - 10.50 9.25 CC5A/CD5AW060 46,500 TDR 10.50 - 10.50 9.50 CE3AA060 46,500 TDR 10.50 - 10.50 9.50 CK3BA060 46,500 TDR 10.50 - 10.50 9.45 CK5A/CK5BA060 46,500 TDR 10.50 - 10.50 9.45 CK5A/CK5BT060 46,500 TDR 10.50 - 10.50 9.45 CK5A/CK5BXO60 47,000 TDR 10.50 - 10.50 9.60 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA060 45,500 TDR 10.50 - 10.50 9.25 CC5A/CD5AW060 46,500 TDR 10.50 - 10.50 9.50 CE3AA060 46,500 TDR 10.50 - 10.50 9.50 CK3BA048 45,500 TDR 10.50 - 10.50 9.30 CK3BA060 46,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BA048 45,500 TDR 10.50 - 10.50 9.30 CK5A/CK5BA060 46,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BT048 45,500 TDR 10.50 - 10.50 9.30 CK5A/CK5BT060 46,500 TDR 10.50 - 10.50 9.50 CK5A/CK5BW048 45,500 TDR 10.50 - 10.50 9.30 CK5A/CK5BX060 47,000 TDR 10.50 - 10.50 9.65 CC5A/CD5AW060* 57,000 NONE 10.00 10.20 10.20 9.20 CC5A/CD5AA060 55,000 NONE 10.00 10.20 10.20 9.05 CK5A/CK5BA060 56,000 NONE 10.00 10.20 10.20 9.15 CK3BA060 56,000 NONE 10.00 10.20 10.20 9.15 CK5NCK5BT060 56,000 NONE 10.00 10.20 10.20 9.15 CK5A/CK5BX060 58,000 NONE 10.20 10.50 10.50 9.35 CE3AA060 57,000 NONE 10.20 10.50 10.50 9.30 F(A,B)4AN(F,B,C)060 57,500 TDR 10.00 - 10.00 8.95 FB4ANB070 58,000 TDR 10.50 - 10.50 9.30 FC4BNB070 58,000 TDR&TXV 10.50 - - 9.30 FC4BN(F,B)060 57,500 TDR&TXV 10.00 - - 8.95 FG3AAA060 56,500 NONE 10.00 - 10.00 9.15 FK4CNB006 58,000 TDR&TXV 11.00 - - 9.75 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE 060-H CC5A/CD5AA060 55,000 TDR 10.50 - 10.50 9.20 CC5A/CD5AW060 56,000 TDR 10.50 - 10.50 9.45 CE3AA060 56,000 TDR 10.50 - 10.50 9.50 CK3BA060 56,000 TDR 10.50 - 10.50 9.35 CK5A/CK5BA060 56,000 TDR 10.50 - 10.50 9.35 CK5A/CK5BT060 56,000 TDR 10.50 - 10.50 9.35 CK5A/CK5BX060 57,000 TDR 10.50 - 10.50 9.65 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AA060 55,000 TDR 10.00 - 10.00 9.05 CC5A/CD5AW060 56,000 TDR 10.50 - 10.50 9.30 CE3AA060 56,000 TDR 10.50 - 10.50 9.35 CK3BA060 56,000 TDR 10.50 - 10.50 9.25 CK5A/CK5BA060 56,000 TDR 10.50 - 10.50 9.25 CK5A/CK5BT060 56,000 TDR 10.50 - 10.50 9.25 CK5A/CK5BX060 57,000 TDR 10.50 - 10.50 9.55 Tested Combination. t In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time -Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD. # TXV must be hard shutoff type; based on computer simulation. NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor /indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other com- binations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. -1 8- DETAILED COOLING CAPACITIES* EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht. s MBtuht Sys MBtuht Sys MBtuht s MBtuht s MBtuht SSyys CFM EWB Total Sens$ 101"` Total Sens$ KW" Total Sens KW Total Sens$ Or* Total Sens$ K W Total Sens$ KIW* S61C018 E Outdoor Section With CC5A /CD5AA018 Indoor,Section 72 20.25 10.25 1.72 19.55 9.99 1.82 18.70 9.68 1.91 17.66 9.28 2.01 16.52 8.85 2.12 15.29 8.38 2.23 525 67 18.76 12.50 1.69 17.85 12.14 1.78 16.78 11.71 1.87 15.63 11.22 1.96 14.49 10.74 2.03 13.30 10.25 2.11 62 16.92 14.58 1.66 15.86 14.07 1.74 14.80 13.55 1.80 13.74 13.00 1.87 12.67 12.40 1.94 11.62 11.62 2.02 57 15.57 15.57 1.63 14.83 14.83 1.70 14.06 14.06 1.77 13.27 13.27 1.85 12.47 12.47 1.93 11.63 11.63 2.02 72 20.51 10.51 1.76 19.85 10.31 1.85 19.04 10.05 1.95 18.02 9.70 2.05 16.87 9.29 2.16 15.62 8.83 227 600 67 19.17 13.10 1.73 18.26 12.79 1.82 17.20 12.41 1.91 16.02 11.93 2.01 14.82 11.44 2.08 13.58 10.95 2.16 62 17.38 15.51 1.69 16.29 15.01 1.78 15.20 14.44 1.85 14.12 13.82 1.92 13.06 13.06 1.99 12.18 12.18 2.08 57 16.33 16.33 1.68 15.55 15.55 1.76 14.73 14.73 1.83 13.91 13.91 1.91 13.06 13.06 1.99 12.18 12.18 2.08 72 20.68 10.74 1.79 20.07 10.58 1.89 19.22 10.34 1.99 18.30 10.08 2.09 17.14 9.69 2.20 15.88 9.26 2.31 675 67 19.46 13.63 1.77 18.57 13.39 1.85 17.54 13.08 1.95 16.35 12.64 2.05 15.08 12.13 2.13 13.80 11.61 2.21 62 17.74 16.35 1.73 16.67 15.86 1.82 15.57 15.24 1.90 14.48 14.48 1.97 13.57 13.57 2.05 12.67 12.67 2.14 57 17.00 17.00 1.72 16.18 16.18 1.81 15.34 15.34 1.89 14.46 14.46 1.97 13.58 13.58 2.05 12.68 12.68 2.14 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 018 1.00 1.00 FK4CNF 001 1.03 0.92 024 1.03 1.01 002 1.05 0.93 CC5A/CD5AW 024 1.03 1.01 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CE3AA 024 1.03 1.02 CC5A/CD5AA 018 1.00 0.92 CF5AA 024 1.04 1.02 024 1.03 0.92 CK3BA 024 1.03 1.02 CE3AA 024 1.03 0.93 CK5A/CK5BA 018 1.00 1.01 CK3BA 024 1.03 0.92 024 1.03 1.02 CK5A/CK5BA 018 1.00 0.92 CK5A/CK5BW 024 1.03 1.02 024 1.03 0.92 F(A,B)4AN(F,C) 018 1.00 0.99 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE 024 1.03 1.01 CC5A/CD5AW 024 1.03 0.95 FC4BNF 024 1.03 1.01 CE3AA 024 1.03 0.95 FF1DNA 018 1.00 0.97 CK5A/CK5BW 024 1.03 0.96 024 1.03 1.02 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE FG3AAA 024 1.03 1.01 CC5A/CD5AW 024 1.03 0.94 - - - CE3AA 024 1.03 0.95 See notes on page 27. -19- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuhf s MBtuht S�yys MBtuht s MBtuht S MBtuht Sys MBtuht Sys CFM EWB Total OM KW** Total Sens$ KW** Total Sens* KW" Total Sens$ KW KW Total Sens$ "* Total Sens# KW'* :_ ', 561CO24 E Outdoor SeationWith CC5AhCD5A''A024.1ndoorSection - 72 27.56 13.98 2.36 26.79 13.73 2.50 25.66 13.32 2.63 24.29 12.81 2.77 22.79 12.23 2.92 21.18 11.61 3.06 700 67 25.58 17.14 2.31 24.41 16.70 2.44 22.96 16.11 2.57 21.42 15.44 2.67 19.89 14.81 2.77 18.36 14.19 2.88 62 23.04 20.01 2.26 21.61 19.33 2.36 20.18 18.62 2.45 18.74 17.87 2.54 17.29 17.12 2.64 16.06 16.06 2.76 57 21.28 21.28 2.21 20.30 20.30 2.31 19.24 19.24 2.41 18.17 18.17 2.51 17.12 17.12 2.63 16.06 16.06 2.76 72 27.93 14.38 2.41 27.24 14.21 2.55 26.16 13.87 2.69 24.83 13.41 2.83 23.34 12.89 2.98 21.69 12.28 3.13 800 67 26.14 18.01 2.37 25.01 17.68 2.49 23.60 17.15 2.62 22.02 16.51 2.75 20.39 15.85 2.85 18.80 15.22 2.96 62 23.70 21.37 2.31 22.24 20.69 2.43 20.80 19.92 2.52 19.25 19.25 2.61 17.98 17.98 2.72 16.89 16.89 2.85 57 22.42 22.42 2.29 21.35 21.35 2.39 20.25 20.25 2.49 19.13 19.13 2.60 17.99 17.99 2.72 16.90 16.90 2.85 72 28.17 14.71 2.46 27.53 14.61 2.60 26.50 14.35 2.74 25.21 13.96 2.89 23.73 13.48 3.04 22.08 12.92 3.19 900 67 26.51 18.75 2.42 25.45 18.56 2.54 24.08 18.11 2.67 22.45 17.51 2.81 20.78 16.84 2.92 19.13 16.17 3.03 62 24.21 22.56 2.36 22.82 21.92 2.48 21.25 21.25 2.58 19.92 19.92 2.69 18.74 18.74 2.80 17.59 17.59 2.93 57 23.35 23.35 2.34 22.25 22.25 2.47 21.12 21.12 2.58 19.93 19.93 2.69 18.75 18.75 2.81 17.60 17.60 2.93 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 024 1.00 1.00 CC5A/CD5AW 030 0.99 0.92 030 1.01 1.00 CE3AA 024 0.97 0.93 CC5A/CD5AW 024 1.00 1.00 030 0.99 0.93 030 1.01 1.00 CK3BA 024 0.97 0.93 CE3AA 024 1.00 1.01 030 0.99 0.92 030 1.01 1.01 CK5A/CK5BA 024 0.97 0.93 CF5AA 024 1.00 1.00 030 0.99 0.92 CK3BA 024 1.00 1.01 CK5A/CK5BW 030 0.99 0.92 030 1.01 1.01 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CK5A/CK5BA 024 1.00 1.01 CC5A/CD5AW 024 0.97 0.95 030 1.01 1.01 030 0.99 0.94 CK5A/CK5BW 024 1.00 1.01 CE3AA 024 0.97 0.96 030 1.01 1.01 030 0.99 0.96 F(A,B)4AN(F,C) 024 1.00 1.00 CK3BA 024 0.97 0.96 030 1.01 1.00 030 0.99 0.95 FC4BNF 024 1.00 1.00 CK5A/CK5BW 024 0.97 0.96 030 1.01 1.00 030 0.99 0.95 FF1DNA 024 1.00 1.01 COLS + 355MAVO42080 VARIABLE -SPEED FURNACE 030 1.01 1.02 CC5A/CD5AW 024 0.97 0.94 FG3AAA 024 0.97 0.98 030 0.99 0.93 FK4CNF 001 1.02 0.93 CE3AA 024 0.97 0.95 002 1.03 0.94 030 0.99 0.95 003 1.03 0.92 CK3BA 024 0.97 0.94 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE 030 0.99 0.94 CC5A/CD5AA 024 0.97 0.92 CK5A/CK5BW 024 0.97 0.94 030 0.99 0.92 030 0.99 0.94 See notes on page 27. -20- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIRTEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht A MBtuhf Sys MBtuhf A MBtuht Sys MBtuhf Sys MBtuht Sys CFM EWB Total Sens# K1iY"" Total Senst KW" Total Senst K1iV'° Total Sens$ KW" Total Sens* KIM• Total Sens# KW" ' " _ • .5610030 A; E Outdoor:Sectiori With CC5A /CD5AA0 0 Indoor Section 72 33.12 17.04 2.80 31.80 16.56 3.00 30.32 16.05 3.20 .20 28.66 15.45 3.40 26.96 14.83 3.61 25.15 14.1 B 3.81 875 67 30.61 21.02 2.74 29.09 20.45 2.92 27.43 19.80 3.11 25.72 19.09 3.29 24.01 18.39 3.45 22.20 17.66 3.60 62 27.70 24.74 2.66 26.08 23.95 2.82 24.48 23.12 2.96 22.95 22.28 3.11 21.36 21.36 3.26 19.98 19.98 3.42 57 26.12 26.12 2.61 24.97 24.97 2.77 23.73 23.73 2.92 22.53 22.53 3.09 21.30 21.30 3.25 19.99 19.99 3.42 72 33.58 17.60 2.87 32.26 17.18 3.07 30.80 16.72 3.27 29.15 16.17 3.48 27.39 15.56 3.68 25.53 14.92 3.89 1000 67 31.21 22.14 2.80 29.67 21.62 2.99 28.00 21.03 3.18 26.27 20.38 3.37 24.45 19.64 3.54 22.57 18.88 3.69 62 28.35 26.34 2.73 26.73 25.54 2.91 25.14 24.62 3.06 23.56 23.56 3.21 22.18 22.18 3.37 20.86 20.86 3.55 57 27.35 27.35 2.70 26.07 26.07 2.88 24.80 24.80 3.03 23.53 23.53 3.20 22.19 22.19 3.37 20.87 20.87 3.55 72 33.89 18.07 2.93 32.57 17.70 3.13 31.10 17.30 3.34 29.50 16.82 3.55 27.68 16.23 3.75 25.79 15.61 3.96 1125 67 31.61 23.13 2.87 30.07 22.69 3.06 28.44 22.19 3.25 26.63 21.55 3.44 24.76 20.80 3.62 22.85 20.01 3.77 62 28.88 27.72 2.79 27.25 27.09 2.97 25.72 25.72 3.15 24.33 24.33 3.32 22.97 22.97 3.49 21.56 21.56 3.67 57 28.28 28.28 2.78 27.03 27.03 2.97 25.70 25.70 3.15 24.34 24.34 3.32 22.99 22.99 3.49 21.57 21.57 3.67 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.04 1.02 CE3AA 030 0.99 0.93 CC5A/CD5AW 030 1.00 1.00 036 1.00 0.93 036 1.04 1.02 CK3BA 030 0.99 0.93 CE3AA 030 1.00 1.01 036 1.02 0.93 036 1.02 1.01 CK5A/CK5BW 036 1.02 0.93 CF5AA 036 1.02 1.01 COILS + 355MAVO42060 VARIABLE -SPEED FURNACE CK3BA 030 1.00 1.00 CC5A/CD5AA 036 1.02 0.97 036 1.04 1.02 CC5A/CD5AW 030 0.99 0.96 CK5A/CK5BA 030 1 1.00 1.00 CE3AA 030 0.99 0.97 036 1.04 1.02 036 1.00 0.97 CK5A/CK5BT 036 1.04 1.02 CK3BA 036 1.02 0.98 CK5A/CK5BW 030 1.00 1.00 CK5A/CK5BA 036 1.02 0.98 036 1.04 1.02 CK5A/CK5BT 036 1.02 0.98 F(A,B)4AN(F,C) 030 1.00 1.00 CK5A/CK5BW 030 0.99 0.97 036 1.01 1.03 COILS + 355MAVO42080 VARIABLE-SPEED FURNACE FC4BNF 030 1.00 1.00 CC5A/CD5AW 030 0.99 0.95 036 1.01 1.03 036 1.02 0.96 FF1DNA 030 1.00 1.01 CE3AA 030 0.99 0.96 FG3AAA 036 1.01 1.01 036 1.00 0.96 FK4CNF 001 1.01 0.94 CK3BA 036 1.02 0.97 002 1.03 0.95 CK5A/CK5BW 030 0.99 0.97 003 1.04 0.93 036 1.02 0.97 005 1.06 0.94 COILS + 355MAV060100 VARIABLE -SPEED FURNACE COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE CC5A/CD5AA 036 1.02 0.96 CC5A/CD5AA 030 0.99 0.93 CC5A/CD5AW 030 0.99 0.95 036 1.02 0.94 036 1.02 0.96 CC5A/CD5AW 030 0.99 0.93 CE3AA 030 0.99 0.96 CE3AA 030 0.99 0.94 036 1.00 0.96 036 1.00 0.94 CK3BA 030 0.99 0.95 CK3BA 030 0.99 0.94 036 1.02 0.96 036 1.02 0.94 CK5A/CK5BA 036 1.02 0.96 CK5A/CK5BA 030 0.99 0.94 CK5A/CK5BT 036 1.02 0.96 036 1.04 0.94 CK5A/CK5BW 030 0.99 0.95 CK5A/CK5BT 036 1.02 0.94 036 1.06 0.96 CK5A/CK5BW 030 0.99 0.94 COILS + 355MAV060120VARIABLESPEEDFURNACE COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CC5A/CD5AW 036 1.02 0.96 CC5A/CD5AW 030 0.99 0.92 CE3AA 030 0.99 0.96 036 1.02 0.93 036 1.00 0.96 - - - CK5A/CK5BW 036 1.02 0.96 See notes on page 27. -21- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sys MBtuht Sy s MBtuht s CFM EWB Total KW"' Total KW"' Total Senst KW"' Total Sens* KW"" Total Senst KIN" Total Sens# Si" 561 CO36 -B E F. Outdoor Section With CC5A /CD5AAO36 Indoor Section ,-_ 72 39.94 20.66 3.29 38.53 20.20 3.54 36.68 19.57 3.78 34.63 18.84 4.04 32.35 18.02 4.31 29.79 17.05 4.56 1050 67 36.96 25.64 3.21 35.15 24.98 3.44 33.06 24.16 3.67 30.86 23.24 3.90 28.56 22.31 4.10 26.07 21.30 4.29 62 33.41 30.21 3.12 31.45 29.25 3.32 29.49 28.24 3.51 27.50 27.12 3.70 25.53 25.53 3.91 23.78 23.78 4.13 57 31.78 31.78 3.08 30.35 30.35 3.28 28.81 28.81 3.47 27.26 27.26 3.69 25.54 25.54 3.91 23.78 23.78 4.13 72 40.47 21.36 3.37 39.07 20.98 3.61 37.28 20.43 3.86 35.27 19.80 4.13 32.89 18.99 4.39 30.32 18.09 4.66 1200 67 37.64 27.06 3.29 35.86 26.50 3.52 33.80 25.78 3.76 31.50 24.87 4.01 29.08 23.89 4.20 26.55 22.86 4.40 62 34.23 32.25 3.20 32.30 31.27 3.42 30.27 30.27 3.61 28.45 28.45 3.82 26.71 26.71 4.04 24.86 24.86 4.27 57 33.28 33.28 3.17 31.73 31.73 3.40 30.16 30.16 3.61 28.46 28.46 3.82 26.72 26.72 4.04 24.86 24.86 4.27 72 40.83 21.96 3.45 39.43 21.67 3.69 37.69 21.21 3.94 35.71 20.68 4.21 33.29 19.90 4.48 30.70 19.04 4.75 1350 67 38.11 28.35 3.37 36.38 27.91 3.59 34.36 27.29 3.84 31.96 26.41 4.08 29.49 25.38 4.30 26.94 24.30 4.50 62 34.91 34.01 3.28 33.08 33.08 3.50 31.24 31.24 3.74 29.49 29.49 3.95 27.70 27.70 4.18 25.73 25.73 4.41 57 34.44 34.44 3.26 32.96 32.96 3.50 31.25 31.25 3.74 29.50 29.50 3.95 _27.71 27.71 4.18 25.73 25.73 4.41 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1.00 1.00 CK5A/CK5BA 042 0.99 0.93 042 1.00 1.00 CK5A/CK5BT 042 0.99 0.93 CC5A/CD5AW 036 1.00 1.00 CK5A/CK5BW 036 0.99 0.93 042 1.00 1.00 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CE3AA 036 0.99 0.99 CC5A/CD5AW 036 0.99 0.92 042 1.00 1.00 042 0.99 0.91 CF5AA 036 1.00 1.00 CE3AA 036 0.98 0.91 CK3BA 036 1.00 1.00 042 0.99 0.92 042 1.00 1.00 CK3BA 042 0.99 0.92 CK5A/CK5BA 036 1.00 1.00 CK5A/CK5BA 042 0.99 0.92 042 1.00 1.00 CK5A/CK5BT 042 0.99 0.92 CK5A/CK5BT 036 1.00 1.00 CK5A/CK5BW 036 0.99 0.92 042 1.00 1.00 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CK5A/CK5BW 036 1.00 1.00 CCSA/CD5AW 036 0.99 0.93 F(A,B)4AN(F,B,C) 042 1.00 1.01 042 0.99 0.92 F(A,B)4AN(F,C) 036 0.99 1.01 CE3AA 036 0.98 0.92 FC4BN(F,B) 042 1.00 1.01 042 0.99 0.93 FC4BNF 036 0.99 1.01 CK3BA 042 0.99 0.92 FG3AAA 036 0.98 0.99 CK5A/CK5BA 042 0.99 0.92 FK4CNB 006 1.05 0.93 CK5A/CK5BT 042 0.99 0.92 FK4CNF 001 0.98 0.94 CK5A/CK5BW 036 0.99 0.92 002 0.98 0.95 COILS + 355MAVO42060 VARIABLE-SPEED FURNACE 003 0.99 0.92 CC5A/CD5AA 036 0.99 0.93 005 1.04 0.93 CE3AA 036 0.97 0.93 COILS + 333(B,J)AV036060 VARIABLE -SPEED FURNACE 042 0.99 0.93 CC5A/CD5AA 036 0.99 0.95 CK3BA 036 0.99 0.94 CE3AA 036 0.98 0.94 CK5NCK5BA 036 0.99 0.93 042 0.99 0.94 CK5A/CK5BT 036 0.99 0.94 CK3BA 036 0.99 0.95 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CK5A/CK5BA 036 0.99 0.95 CC5A/CD5AA 042 0.99 0.92 CK5A/CK5BT 036 0.99 0.95 CC5A/CD5AW 036 0.99 0.92 CK5A/CK5BW 036 0.99 0.95 042 0.98 0.92 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CE3AA 036 0.97 0.92 CC5A/CD5AA 042 0.99 0.92 042 0.96 0.92 CC5A/CD5AW 036 0.99 0.93 CK3BA 042 0.99 0.92 042 0.99 0.92 CK5NCK5BA 042 0.99 0.92 CE3AA 036 0.98 0.93 CK5A/CK5BT 042 0.99 0.92 042 0.99 0.93 CK5A/CK5BW 036 0.99 0.93 CK3BA 036 0.99 0.93 COILS + 355MAV060080 VARIABLE -SPEED FURNACE 042 0.99 0.93 CC5A/CD5AA 1 042 1 0.99 I 0.96 See notes on page 27. -22-- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht Sys MBtuht SSyys MBtuht SSyys MBtuht s MBtuht Sy MBtuht Sys CFM EWB Total Senst KW" Total Senst KW"' Total OM KUIP KW * Total Senst " Total Senst OM Total Senst KW'° 561CO36 B E F Outdoor Section Witty CC5A` /CD6AA036 IndoorSectlon';'continuad 72 39.94 20.66 3.29 38.53 20.20 3.54 36.68 19.57 3.78 34.63 18.84 4.04 32.35 18.02 4.31 29.79 17.05 4.56 1050 67 36.96 25.64 3.21 35.15 24.98 3.44 33.06 24.16 3.67 30.86 23.24 3.90 28.56 22.31 4.10 26.07 21.30 4.29 62 33.41 30.21 3.12 31.45 29.25 3.32 29.49 28.24 3.51 27.50 27.12 3.70 25.53 25.53 3.91 23.78 23.78 4.13 57 31.78 31.78 3.08 30.35 30.35 3.28 28.81 28.81 3.47 27.26 27.26 3.69 25.54 25.54 3.91 23.78 23.78 4.13 72 40.47 21.36 3.37 39.07 20.98 3.61 37.28 20.43 3.86 35.27 19.80 4.13 32.89 18.99 4.39 30.32 18.09 4.66 1200 67 37.64 27.06 3.29 35.86 26.50 3.52 33.80 25.78 3.76 31.50 24.87 4.01 29.08 23.89 4.20 26.55 22.86 4.40 62 34.23 32.25 3.20 32.30 31.27 3.42 30.27 30.27 3.61 28.45 28.45 3.82 26.71 26.71 4.04 24.86 24.86 4.27 57 33.28 33.28 3.17 31.73 31.73 3.40 30.16 30.16 3.61 28.46 28.46 3.82 26.72 26.72 4.04 24.86 24.86 4.27 72 40.83 21.96 3.45 39.43 21.67 3.69 37.69 21.21 3.94 35.71 20.68 4.21 33.29 19.90 4.48 30.70 19.04 4.75 1350 67 38.11 28.35 3.37 36.38 27.91 3.59 34.36 27.29 3.84 31.96 26.41 4.08 29.49 25.38 4.30 26.94 24.30 4.50 62 34.91 34.01 3.28 33.08 33.08 3.50 31.24 31.24 3.74 29.49 29.49 3.95 27.70 27.70 4.18 25.73 25.73 4.41 57 34.44 34.44 3.26 32.96 32.96 3.50 31.25 31.25 3.74 29.50 29.50 3.95 27.71 27.71 4.18 25.73 25.73 4.41 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AW 036 0.99 0.92 CK3BA 042 0.99 0.92 042 0.98 0.91 CK5A/CK5BA 042 0.99 0.92 CE3AA 036 0.97 0.92 CK5A/CK5BT 042 0.99 0.92 042 0.99 0.92 CK5A/CK5BW 036 0.99 0.92 CK3BA 042 0.99 0.93 COILS + 355MAV060120 VARIABLE -SPEED FURNACE CK5A/CK5BA 042 0.99 0.93 CC5A/CD5AA 042 0.99 0.92 CK5A/CK5BT 042 0.99 0.93 CC5A/CD5AW 036 0.99 0.92 CK5A/CK5BW 1 036 0.99 0.94 042 0.98 0.91 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CE3AA 036 0.98 0.92 CC5A/CD5AA 042 0.99 0.92 042 0.99 0.92 CC5A/CD5AW 036 0.99 0.92 CK5A/CK5BA 042 0.99 0.92 042 0.98 0.91 CK5A/CK5BT 042 0.99 0.92 CE3AA 036 0.97 0.92 CK5A/CK5BW 036 0.99 0.92 042 0.99 0.92 - - - See notes on page 27. -23- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIRTEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht S MBtuht S MBtuht SSyys MBtuht Sys MBtuht S�yys MBt_uht S$yys CFM EWB Total KW'` Total Sens# K W'* Total 10I" Total Sens FOP* Total Sens IVV Total Sens$ KW'• • ;.' 5610042-13 Outdo ,Section'With'CC5A /CD5AA042 Indoor= Section 72 46.29 23.66 3.77 45.13 23.29 4.12 43.60 22.76 4.50 41.68 22.03 4.89 39.58 21.23 5.28 37.31 20.36 5.69 1225 67 42.99 29.14 3.68 41.55 28.63 4.04 39.71 27.86 4.42 37.62 26.97 4.77 35.39 26.03 5.09 32.98 25.04 5.41 62 39.32 34.41 3.62 37.52 33.55 3.95 35.54 32.58 4.25 33.52 31.56 4.56 31.37 30.43 4.87 29.04 29.04 5.16 57 36.80 36.80 3.57 35.42 35.42 3.87 33.95 33.95 4.19 32.40 32.40 4.51 30.77 30.77 4.83 28.98 28.98 5.16 72 46.92 24.37 3.85 45.80 24.09 4.22 44.25 23.63 4.59 42.37 23.00 4.98 40.25 22.23 5.38 37.94 21.40 5.78 1400 67 43.78 30.57 3.77 42.31 30.16 4.12 40.50 29.51 4.50 38.44 28.66 4.89 36.16 27.73 5.22 33.63 26.72 5.54 62 40.13 36.56 3.70 38.39 35.75 4.06 36.39 34.71 4.36 34.34 33.58 4.68 32.18 32.18 4.99 30.24 30.24 5.31 57 38.41 38.41 3.67 37.00 37.00 4.00 35.43 35.43 4.32 33.84 33.84 4.65 32.13 32.13 4.99 30.25 _ 30.25 5.31 72 47.40 25.02 3.94 46.26 24.82 4.30 44.69 24.40 4.68 42.90 23.90 5.07 40.76 23.19 5.47 38.37 22.36 5.86 1575 67 44.32 31.89 3.85 42.90 31.61 4.20 41.12 31.09 4.58 39.04 30.33 4.97 36.74 29.40 5.33 34.16 28.37 5.65 62 40.78 38.51 3.78 39.10 37.73 4.14 37.02 37.02 4.47 35.14 35.14 4.79 33.31 33.31 5.13 31.39 31.39 5.47 57 39.71 39.71 3.76 38.36 38.36 4.12 36.78 36.78 4.45 35.12 35.12 4.79 33.32 33.32 5.13 31.41 31.41 5.47 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit 1 Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 042 1.00 1.00 CK5A/CK5BW 048 1.00 0.93 048 1.01 1.00 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CC5A/CD5AC 048 1.00 0.99 CC5A/CD5AW 042 0.99 0.94 CC5A/CD5AW 042 1.00 1.00 048 1.00 0.93 048 1.01 1.00 CE3AA 042 0.99 0.94 CE3AA 042 1.00 1.00 048 1.00 0.95 048 1.01 1.01 CK3BA 042 0.99 0.93 CF5AA 048 1.01 1.00 048 1.00 0.93 CK3BA 042 1.00 1.00 CK5A/CK5BA 042 0.99 0.93 048 1.01 1.00 CK5A/CK5BT 042 0.99 0.93 CK5A/CK5BA 042 1.00 1.00 CK5A/CK5BW 048 1.00 0.93 048 1.01 1.00 COILS + 355MAVO42080 VARIABLE -SPEED FURNACE CK5A/CK5BT 042 1.00 1.00 CC5A/CD5AA 042 0.99 0.94 048 1.01 1.00 048 1.00 0.93 CK5A/CK5BW 048 1.01 1.00 CC5A/CD5AW 042 0.99 0.94 F(A,B)4AN(F,B,C) 042 1.00 1.01 CE3AA 042 0.99 0.95 048 1.01 1.02 048 1.00 0.95 FC4BN(F,B) 042 1.00 1.01 CK5A/CK5BA 048 1.00 0.95 048 1.01 1.02 CK5A/CK5BT 048 1.00 0.95 FC4BNB 054 1.02 1.01 COILS + 355MAV060080 VARIABLE -SPEED FURNACE FG3AAA 048 1.00 1.00 CC5A/CD5AA 042 0.99 0.94 FK4CNB 006 1.04 0.94 048 1.00 0.93 003 1.00 0.94 CC5A/CD5AW 042 0.99 0.93 005 1.02 0.95 CE3AA 042 0.99 0.94 COILS + 333(B,J)AVO48080 VARIABLE-SPEED FURNACE 048 1.00 0.94 CC5A/CD5AA 042 0.99 0.94 CK5A/CK5BA 048 1.00 0.96 048 1.00 0.94 CK5A/CK5BT 048 1.00 0.96 CC5A/CD5AC 048 0.99 0.93 COILS + 355MAV060100 VARIABLE -SPEED FURNACE CC5A/CD5AW 042 0.99 0.94 CC5A/CD5AA 042 0.99 0.94 CE3AA 042 0.99 0.95 048 1.00 0.93 048 1.00 0.95 CC5A/CD5AW 042 0.99 0.93 CK3BA 042 0.99 0.95 CE3AA 042 0.99 0.94 048 1.00 0.95 048 1.00 0.94 CK5A/CK5BA 042 0.99 0.95 CK3BA 048 1.00 0.93 048 1.00 0.95 CK5A/CK5BA 048 1.00 0.93 CK5A/CK5BT 042 0.99 0.95 CK5A/CK5BT 048 1.00 0.93 048 1.00 0.95 COILS + 355MAV060120 VARIABLE -SPEED FURNACE COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CC5A/CD5AA 042 0.99 0.94 CC5A/CD5AW 042 0.99 0.93 CC5A/CD5AW 042 0.99 0.93 048 1.00 0.92 048 1.00 0.93 CE3AA 042 0.99 0.93 CE3AA 042 0.99 0.94 048 1.00 0.94 048 1.00 0.94 CK3BA 042 0.99 0.93 CK3BA 048 1.00 0.94 048 1.00 0.93 CK5A/CK5BA 048 1.00 0.94 CK5A/CK5BA 042 0.99 0.93 CK5A/CK5BT 048 1.00 0.94 CK5A/CK5BT 042 0.99 0.93 CK5A/CK5BW 048 _ 1.00 0.94 See notes on page 27. -24- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht S MBtuht SSyy MBtuht MBtuht ss MBtuht Sys MBtuht SSyys CFM EWB Total I KW** Total Sens$ KW* Total Sens* KW'* Total Sens# KW** Total Sens* la** Total Sens* KW . 1 ` 147 _ 0 1 . ... . l a 1 1 h . o , 1....14:' . i • `;. , i. R 72 50.02 25.82 4.10 48.84 25.47 4.45 47.33 24.99 4.84 45.43 24.28 5.27 43.35 23.50 5.74 41.09 22.66 6.25 1400 67 46.57 32. 4.04 45.06 31.59 4.40 43.20 30.84 4.80 41.17 29.97 5.22 38.92 29.04 5.64 36.47 28.04 6.07 62 42.57 38.09 4.00 40.76 37.19 4.34 38.79 36.20 4.69 36.78 35.14 5.06 34.61 33.94 5.47 32.34 32.34 5.90 57 40.22 40.22 3.97 38.86 38.86 4.29 37.41 37.41 4.65 35.83 35.83 5.04 34.15 34.15 5.45 32.33 32.33 5.90 72 50.64 26.62 4.20 49.53 26.37 4.55 48.01 25.99 4.94 46.12 25.36 5.36 44.02 24.63 5.83 41.73 23.82 6.34 1600 67 47.35 33.74 4.14 45.85 33.38 4.49 44.00 32.72 4.89 41.99 31.93 5.33 39.73 30.99 5.76 37.20 29.99 6.20 62 43.42 40.47 4.08 41.68 39.62 4.45 39.67 38.52 4.80 37.58 37.58 5.18 35.64 35.64 5.59 33.72 33.72 6.03 57 41.99 41.99 4.07 40.56 40.56 4.42 38.99 38.99 4.78 37.38 37.38 5.17 35.66 35.66 5.59 33.73 33.73 6.03 72 51.07 27.31 4.29 49.93 27.16 4.64 48.48 26.88 5.03 46.62 26.35 5.46 44.50 25.66 5.93 42.14 24.88 6.43 1800 67 47.85 35.19 4.23 46.42 35.03 4.58 44.59 34.47 4.97 42.55 33.74 5.41 40.31 32.84 5.88 37.70 31.80 6.31 62 44.09 42.54 4.17 42.40 41.76 4.54 40.46 40.46 4.91 38.68 38.68 5.30 36.87 36.87 5.73 34.90 34.90 6.18 57 43.30 43.30 4.16 41.95 41.95 4.53 40.35 40.35 4.90 38.70 38.70 5.30 36.88 36.88 5.73 34.92 34.92 6.18 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 048 1.00 1.00 CK3BA 048 0.99 0.94 060 1.00 1.00 060 1.01 0.94 CC5A/CD5AC 048 0.98 0.99 CK5A/CK5BA 060 1.01 0.94 CC5A/CD5AW 048 1.00 1.00 CK5A/CK5BT 060 1.01 0.94 060 1.02 1.01 CK5A/CK5BW 048 0.99 0.94 CE3AA 048 1.00 1.00 CK5A/CK5BX 060 1.02 0.94 060 1.02 1.01 COILS +333(B,J)AV060120 VARIABLE -SPEED FURNACE CF5AA 048 1.00 0.99 CC5A/CD5AA 060 0.99 0.94 CK3BA 048 1.00 1.00 CC5A/CD5AW 048 0.99 0.94 060 1.02 1.01 060 1.01 0.95 CK5A/CK5BA 048 1.00 1.00 CE3AA 048 0.99 0.95 060 1.02 1.01 060 1.01 0.95 CK5A/CK5BT 048 1.00 1.00 CK3BA 048 0.99 0.94 060 1.02 1.01 060 1.01 0.95 CK5A/CK5BW 048 1.00 1.00 CK5A/CK5BA 060 1.01 0.95 CK5A/CK5BX 060 1.02 1.01 CK5A/CK5BT 060 1.01 0.95 F(A,B)4AN(F,B,C) 048 1.01 1.02 CK5A/CK5BW 048 0.99 0.94 060 1.03 1.04 CK5A/CK5BX 060 1.02 0.95 FB4ANB 070 1.05 1.03 COILS + 355MAV060080 VARIABLE -SPEED FURNACE FC4BN(F,B) 048 1.01 1.02 CC5A/CD5AA 060 0.99 0.95 060 1.03 1.04 CC5A/CD5AW 060 1.01 0.96 FC4BNB 054 1.05 1.02 CE3AA 060 1.01 0.96 070 1.05 1.03 COILS +355MAV060100VARIABLE -SPEED FURNACE FG3AAA 048 0.98 1.00 CC5A/CD5AA 060 0.99 0.95 060 1.00 1.01 CC5A/CD5AW 060 1.01 0.96 FK4CNB 006 1.06 0.94 CE3AA 060 1.01 0.96 FK4CNF 005 1.03 0.95 CK3BA 060 1.01 0.96 COILS +333(B,J)AVO48080 VARIABLE -SPEED FURNACE CK5A/CK5BA 060 1.01 0.96 CC5A/CD5AA 048 0.99 0.95 CK5A/CK5BT 060 1.01 0.96 CC5A/CD5AC 048 0.98 0.95 CK5A/CK5BX 060 1.02 0.96 CE3AA 048 0.99 0.97 COILS + 355MAV060120 VARIABLE -SPEED FURNACE 060 1.01 0.96 CC5A/CD5AA 060 0.99 0.95 CK3BA 048 0.99 0.97 CC5A/CD5AW 060 1.01 0.96 CK5A/CK5BA 048 0.99 0.97 CE3AA 060 1.01 0.96 CK5A/CK5BT 048 0.99 0.97 CK3BA 048 0.99 0.95 COILS +333(B,J)AV060100 VARIABLE -SPEED FURNACE 060 1.01 0.96 CC5A/CD5AA 060 0.99 0.93 CK5A/CK5BA 048 0.99 0.95 CC5A/CD5AW 048 0.99 0.93 060 1.01 0.96 060 1.01 0.94 CK5A/CK5BT 048 0.99 0.95 CE3AA 048 0.99 0.94 060 1.01 0.96 060 1.01 0.94 CK5A/CK5BW 048 0.99 0.95 - - - CK5A/CK5BX 060 1.02 0.96 See notes on page 27. -25- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacfty Total Capacity Total MBtuht a MBtuht SSyys MBtuht a MBtuht Sys MBtuht Sy MBtuht Sys CFM EWB Total Senst i(W Total Senst K Total Senst KW" Total OM KW'* Total Sens* K61/'• Total Sens* KW'* : '561C048 F:Outdoorr With CD5AA048'Indoor Section -_ 72 52.15 26.71 4.28 50.93 26.32 4.65 49.35 25.76 5.07 47.45 25.07 5.53 45.28 24.23 6.02 42.93 23.34 6.56 1400 67 48.54 32.98 4.22 47.00 32.42 4.60 45.12 31.66 5 .03 42.92 30.69 5.46 40.62 .73 5.90 38 7 .12 26.0 6.36 62 44.42 38.98 4.17 42.53 38.06 4.53 40.48 37.04 4.89 38.33 35.96 5.29 36.07 34 5.71 33.59 33.59 6.15 57 41.62 41.62 4.13 40.15 40.15 4.46 38.59 38.59 4.83 37.00 37.00 5.25 35.27 35.27 5.68 33.41 33.41 6.14 72 52.80 27.51 4.38 51.66 27.24 4.75 50.11 26.78 5.16 48.22 26.17 5.62 46.02 25.37 6.11 43.64 24.51 6.65 1600 67 49.41 4.31 47.91 34.23 4.69 46.00 33. 5.11 43.84 32.65 5.58 41.50 31.69 6.03 38.93 30.67 6.49 62 45.41 41.2( 4.26 43.55 40.60 4.65 41.42 39.49 5.01 39.24 38.27 5.40 36.98 36.98 5.83 34.93 34.93 6.30 57 43.46 43.46 4.24 41.95 41.95 4.60 40.33 40.33 4.97 38.63 38.63 5.38 36.85 36.85 5.83 34.95 34.95 6.30 72 53.25 28.20 4.47 52.20 28.04 4.85 50.61 27.66 5.26 48.77 27.15 5.71 46.55 26.42 6.21 44.15 25.60 6.73 1800 67 50.03 36.13 4.40 48.53 3 5.85 4.77 46.65 35.31 5.19 44.49 34.51 5.66 42.17 33.57 6.15 39.57 32.54 6.61 62 46.11 43.67 4.34 44.33 42.80 4.73 42.08 42.08 5.11 40.08 40.08 5.52 38.20 38.20 5.97 36.19 36.19 6.45 57 44.93 44.93 4.33 43.48 43.48 4.73 41.78 41.78 5.10 40.02 40.02 5.51 38.21 38.21 5.97 36.21 36.21 6.45 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit Cooling Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 048 1.00 1.00 CK3BA 048 0.99 0.94 060 1.01 1.00 060 1.01 0.94 CC5A/CD5AC 048 0.98 0.99 CK5A/CK5BA 060 1.01 0.94 CC5A/CD5AW 048 1.00 1.00 CK5A/CK5BT 060 1.01 ' 0.94 060 1.02 1.01 CK5A/CK5BW 048 0.99 0.94 CE3AA 048 1.00 1.00 CK5A/CK5BX 060 1.02 0.94 060 1.02 1.01 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE CF5AA 048 1.00 0.99 CC5A/CD5AA 060 1.00 0.95 CK3BA 048 1.00 1.00 CC5A/CD5AW 048 0.99 0.95 060 1.02 1.01 060 1.01 0.95 CK5A/CK5BA 048 1.00 1.00 CE3AA 048 0.99 0.96 060 1.02 1.01 060 1.01 0.96 CK5A/CK5BT 048 1.00 1.00 CK3BA 048 0.99 0.95 060 1.02 1.01 060 1.01 0.95 CK5A/CK5BW 048 1.00 1.00 CK5A/CK5BA 060 1.01 0.95 CK5A/CK5BX 060 1.02 1.02 CK5A/CK5BT 060 1.01 0.95 F(A,B)4AN(F,B,C) 048 1.01 1.02 CK5A/CK5BW 048 0.99 0.95 060 1.04 1.05 CK5A/CK5BX 060 1.02 0.95 FB4ANB 070 1.07 1.03 COILS + 355MAV060080 VARIABLE -SPEED FURNACE FC4BN(F,B) 048 1.01 1.02 CC5A/CD5AA 060 0.99 0.96 060 1.04 1.04 CC5A/CD5AW 060 1.01 0.96 FC4BNB 054 1.05 1.02 CE3AA 060 1.01 0.96 070 1.07 1.03 COILS + 355MAV060100 VARIABLE -SPEED FURNACE FG3AAA 048 1.00 1.00 CC5A/CD5AA 060 0.99 0.96 060 1.02 1.01 CC5A/CD5AW 060 1.01 0.96 FK4CNB 006 1.05 0.95 CE3AA 060 1.01 0.96 FK4CNF 005 1.03 0.96 CK3BA 060 1.01 0.96 COILS + 333(B,J)AVO48080 VARIABLE -SPEED FURNACE CK5A/CK5BA 060 1.01 0.96 CC5A/CD5AA 048 0.99 0.96 CK5A/CK5BT 060 1.01 0.96 CC5A/CD5AC 048 0.98 0.95 CK5A/CK5BX 060 1.02 0.97 CE3AA 048 0.99 0.97 COILS + 355MAV060120 VARIABLE -SPEED FURNACE 060 1.01 0.97 CC5A/CD5AA 060 0.99 0.96 CK3BA 048 0.99 0.97 CC5A/CD5AW 060 1.01 0.96 CK5A/CK5BA 048 0.99 0.97 CE3AA 060 1.01 0.96 CK5A/CK5BT 048 0.99 0.97 CK3BA 048 0.99 0.96 COILS + 333(B,J)AVO60100 VARIABLE -SPEED FURNACE 060 1.01 0.96 CC5A/CD5AA 060 1.00 0.94 CK5A/CK5BA 048 0.99 0.96 CC5A/CD5AW 048 0.99 0.94 060 1.01 0.96 060 1.01 0.94 CK5A/CK5BT 048 0.99 0.96 CE3AA 048 0.99 0.95 060 1.01 0.96 060 1.01 0.95 CK5A/CK5BW ' 048 0.99 0.96 - - - CK5A/CK5BX 060 _ 1.02 0.97 See notes on page 27. -26-- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES °F AIR 75 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht z MBtuht Sys MBtuht SSyys MBtuht Sys MBtuht SSyys MBtuht CFM CFM EWB Total Sens KW" Total Sens KW" Total Sons KW* Total Sens KW"' Total Sens WI" Total Senst KW" 561C060 HO ltdoor Section With CC5A /CD5AW060 Indoor Section'-: 72 65.64 33.89 5.33 63.80 33.32 5.81 61.47 32.48 6.34 58.69 31.45 6.92 55.71 30.33 7.54 52.51 29.14 8.18 1775 67 60.86 41.99 5.23 58.67 41.16 5.71 56.15 40.11 6.23 53.36 38.91 6.81 50.21 37.62 7.34 46.77 36.22 7.90 62 55.51 49.61 5.13 53.16 48.46 5.57 50.64 47.19 6.02 47.87 45.76 6.51 44.88 44.10 7.03 41.81 41.81 7.58 57 52.57 52.57 5.07 50.70 50.70 5.48 48.79 48.79 5.96 46.71 46.71 6.47 44.36 44.36 7.00 41.83 41.83 7.59 72 66.37 34.83 5.44 64.52 34.34 5.92 62.25 33.67 6.45 59.43 32.67 7.03 56.43 31.61 7.64 53.19 30.45 8.28 2000 67 61.83 43.95 5.34 59.63 43.24 5.81 57.00 42.23 6.33 54.19 41.11 6.90 51.04 39.81 7.49 47.54 38.42 8.05 62 56.59 52.46 5.24 54.18 51.25 5.72 51.59 49.85 6.17 48.67 48.67 6.65 45.97 45.97 7.20 43.35 43.35 7.79 57 54.51 54.51 5.20 52.64 52.64 5.64 50.62 50.62 6.13 48.40 48.40 6.64 45.99 45.99 7.20 43.37 43.37 7.79 72 66.96 35.78 5.56 65.17 35.42 6.04 62.90 34.87 6.57 60.06 33.95 7.15 57.04 32.93 7.75 53.79 31.82 8.39 2250 67 62.64 45.96 5.46 60.40 45.42 5.93 57.74 44.50 6.44 54.88 43.44 7.01 51.76 42.19 7.64 48.17 40.74 8.22 62 57.48 55.24 5.35 55.10 53.95 5.83 52.51 52.51 6.32 50.04 50.04 6.84 47.55 47.55 7.41 44.79 44.79 7.99 57 56.36 56.36 5.34 54.44 54.44 5.82 52.34 52.34 6.32 50.06 50.06 6.84 47.57 47.57 7.41 44.81 44.81 7.99 Multipliers for Determining the Performance With Other Indoor Sections Indoor Unit I fi I Indoor Unit Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 0.96 0.98 CC5A/CD5AW 060 0.98 0.96 CC5A/CD5AW 060 1.00 1.00 CE3AA 060 0.98 0.97 CE3AA 060 1.00 1.00 CK3BA 060 0.98 0.96 CK3BA 060 0.98 1.00 CK5A/CK5BA 060 0.98 0.96 CK5A/CK5BA 060 0.98 1.00 CK5A/CK5BT 060 0.98 0.96 CK5A/CK5BT 060 0.98 1.00 CK5A/CK5BX 060 1.00 0.96 CK5A/CK5BX 060 1.02 1.01 COILS + 333(B,J)AV060120 VARIABLE -SPEED FURNACE F(A,B)4AN(F,B,C) _ 060 1.01 1.04 CC5A/CD5AA 060 0.96 0.97 FB4ANB 070 1.02 1.02 CC5A/CD5AW 060 0.98 _ 0.97 FC4BN(F,B) 060 1.01 1.04 CE3AA 060 0.98 0.98 FC4BNB 070 1.02 1.02 CK3BA 060 0.98 0.97 FG3AAA 060 0.99 1.00 CK5A/CK5BA 060 0.98 0.97 FK4CNB 006 1.02 0.97 CK5A/CK5BT 060 0.98 0.97 COILS + 333(B,J)AV060100 VARIABLE -SPEED FURNACE CK5A/CK5BX 060 1.00 0.97 CC5A/CD5AA J 060 I 0.96 1 0.96 I - - - * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. t Total and sensible capacities are net capacities. Blower motor heat has been subtracted. $ Sensible capacities shown are based on 80 °F (27 °C) entering air at the indoor coil. For sensible capacities at other than 80 °F (27 °C), deduct 835 Btuh (245 kw) per 1000 CFM (480 US) of indoor coil air for each degree below 80 °F (27 °C), or add 835 Btuh (245 kw) per 1000 CFM (480 US) of indoor coil air per degree above 80 °F (27 °C). When the required data falls between the published data, interpolation may be performed. " Unit kw is total of indoor and outdoor unit kilowatts. EWB-Entering Wet Bulb -27- I I • CONDENSER ONLY RATINGS* SST CONDENSER ENTERING AIR TEMPERATURES °F °F 55 65 75 85 95 105 115 125 ��,_. 561C018E TCG 17.60 16.00 14.40 12.90 11.30 9.90 8.50 7.10 30 KW 90.30 98.50 106.70 114.90 123.20 131.20 139.00 146.60 SDT 1.21 1.27 1.32 1.37 1.41 1.44 1.46 1.47 35 TCG 19.70 18.00 16.30 14.60 13.00 11.50 10.00 8.50 KW 93.00 101.10 109.20 117.30 125.40 133.50 141.10 148.60 SDT 1.25 1.32 1.38 1.43 1.49 1.53 1.56 1.59 40 TCG 21.80 20.00 18.20 16.50 14.80 13.10 11.40 9.80 KW 95.80 103.80 111.70 119.70 127.70 135.70 143.20 150.50 SDT 1.30 1.37 1.43 1.50 1.56 1.62 1.66 1.70 45 TCG 24.00 22.10 20.20 18.40 16.50 14.70 12.90 11.10 KW 98.60 106.50 114.30 122.20 130.00 137.80 145.20 152.20 SDT 1.34 1.42 1.49 1.56 1.64 1.70 1.76 1.81 50 TCG 26.20 24.20 22.30 20.30 18.30 16.30 14.40 12.40 KW 101.50 109.20 116.90 124.60 132.30 139.90 147.10 153.70 SDT 1.39 1.47 1.55 1.63 1.71 1.78 1.85 1.91 55 TCG 28.50 26.40 24.30 22.20 20.10 18.00 15.80 13.70 KW 104.40 111.90 119.50 127.00 134.50 141.90 148.80 155.20 SDT 1.43 1.52 1.60 1.69 1.78 1.86 1.93 2.00 TCG 24.60 22.40 20.40 18.30 16.40 14.50 12.80 11.10 30 KW 92.40 99.70 107.10 114.70 122.20 129.90 137.80 145.70 SDT 1.66 1.73 1.79 1.85 1.90 1.95 2.00 2.06 TCG 27.30 25.10 22.90 20.70 18.60 16.60 14.70 12.80 35 KW 95.60 102.90 110.20 117.50 125.00 132.50 140.10 147.70 SDT 1.74 1.82 1.89 1.96 2.02 2.08 2.14 2.21 40 TCG 30.20 27.90 25.50 23.20 21.00 18.80 16.60 14.50 KW 99.00 106.10 113.30 120.50 127.70 135.00 142.30 149.70 SDT 1.82 1.91 1.99 2.07 2.14 2.21 2.28 2.36 45 TCG 33.10 30.60 28.20 25.70 23.30 20.90 18.60 16.20 KW 102.40 109.40 116.40 123.40 130.50 137.50 144.70 151.70 SDT 1.90 2.00 2.09 2.18 2.27 2.35 2.43 2.51 50 TCG 36.00 33.40 30.80 28.30 25.70 23.10 20.50 17.80 KW 105.80 112.60 119.50 126.40 133.20 140.10 146.90 153.50 SDT 1.98 2.09 2.19 2.29 2.39 2.48 2.57 2.66 55 TCG 39.00 36.20 33.50 30.80 28.00 25.30 22.40 19.50 KW 109.30 115.90 122.60 129.30 135.90 142.50 149.10 155.40 SDT 2.07 2.18 2.29 2.40 2.51 2.61 2.71 2.80 A _ .., - 5610030 • E _... , :.., - , :.. 30 TCG 29.90 27.40 25.10 22.80 20.70 18.60 16.50 14.30 KW 98.20 106.50 114.90 123.20 131.50 139.70 147.80 154.90 SDT 1.91 2.02 2.12 2.22 2.30 2.39 2.47 2.55 35 TCG 32.90 30.30 27.80 25.30 22.90 20.60 18.20 15.80 KW 101.10 109.30 117.50 125.60 133.80 141.80 149.60 156.40 SDT 2.00 2.12 2.24 2.35 2.44 2.54 2.63 2.71 40 TCG 36.10 33.30 30.60 27.90 25.30 22.70 19.90 17.30 KW 104.00 112.10 120.10 128.10 136.00 143.80 151.20 157.80 SDT 2.09 2.23 2.35 2.47 2.58 2.69 2.79 2.87 TCG 39.30 36.30 33.40 30.50 27.60 24.70 21.60 18.80 45 KW 107.00 114.90 122.80 130.60 138.30 145.70 152.80 159.10 SDT 2.18 2.33 2.47 2.60 2.72 2.83 2.94 3.02 TCG 42.60 39.40 36.20 33.10 29.90 26.70 23.30 20.50 50 KW 110.00 117.70 125.40 133.00 140.40 147.60 154.30 160.00 SDT 2.27 2.43 2.58 2.72 2.86 2.98 3.09 3.17 55 TCG 45.90 42.50 39.10 35.70 32.20 28.70 25.00 22.40 KW 113.00 120.50 128.00 135.40 142.50 149.40 155.60 160.70 SDT 2.36 2.53 2.69 2.85 2.99 3.12 3.24 3.31 `r 561 =F TCG 35.60 32.70 29.80 26.80 23.80 20.90 18.00 15.20 30 KW 95.20 103.60 112.00 120.30 128.50 136.60 144.50 151.50 SDT 2.20 2.35 2.49 2.62 2.74 2.84 2.92 2.97 TCG 39.20 36.20 33.10 30.00 26.80 23.70 20.50 17.40 35 KW 97.90 106.20 114.50 122.70 130.80 138.80 146.50 153.30 SDT 2.30 2.46 2.61 2.76 2.90 3.02 3.12 3.20 40 TCG 43.00 39.80 36.50 33.20 29.80 26.40 22.90 19.50 KW 100.70 108.90 117.00 125.10 133.10 140.90 148.40 154.90 SDT 2.40 2.57 2.73 2.90 3.05 3.20 3.32 3.41 45 TCG 46.90 43.50 40.00 36.50 32.90 29.20 25.40 21.60 KW 103.50 111.60 119.60 127.50 135.30 142.90 150.20 156.50 SDT 2.50 2.68 2.85 3.03 3.20 3.36 3.51 3.62 50 TCG 50.80 47.20 43.50 39.70 35.90 31.90 27.70 23.70 KW 106.40 114.30 122.10 129.90 137.50 144.90 151.90 157.90 SDT 2.61 2.79 2.98 3.17 3.35 3.52 3.68 3.81 TCG 54.80 50.90 47.00 43.00 38.90 34.60 29.90 25.80 55 KW 109.30 117.00 124.70 132.20 139.60 146.70 153.40 159.20 SDT 2.72 2.91 3.10 3.30 3.49 3.67 3.85 3.97 See notes on page 26. -28- 1 , . • CONDENSER ONLY RATINGS* Continued SST CONDENSER ENTERING AIRTEMPERATURES °F °F 55 65 75 85 95 105 115 125 TCG 42.90 40.20 37.60 34.80 32.00 29.10 26.00 22.70 30 KW 95.70 104.00 112.20 120.40 128.40 136.20 143.90 151.20 SDT 2.55 2.79 3.03 3.27 3.49 3.70 3.89 4.05 35 TCG 46.80 44.00 41.10 38.10 35.10 31.90 28.60 24.90 KW 98.70 106.80 114.90 122.90 130.80 138.40 145.90 153.00 SDT 2.65 2.90 3.16 3.41 3.64 3.87 4.08 4.26 40 TCG 50.80 47.80 44.70 41.50 38.20 34.80 31.10 27.00 KW 101.70 109.70 117.70 125.50 133.20 140.70 147.90 154.80 SDT 2.76 3.02 3.28 3.55 3.80 4.04 4.26 4.47 45 TCG 54.90 51.70 48.30 44.90 41.40 37.60 33.60 29.20 KW 104.90 112.70 120.50 128.10 135.60 142.90 149.80 156.50 SDT 2.87 3.14 3.41 3.68 3.95 4.20 4.44 4.66 TCG 59.20 55.70 52.10 48.40 44.50 40.50 36.10 31.50 50 KW 108.10 115.70 123.30 130.80 138.00 145.00 151.70 158.30 SDT 2.97 3.25 3.54 3.82 4.10 4.36 4.61 4.84 55 TCG 63.50 59.70 55.90 51.90 47.70 43.30 38.50 34.00 KW 111.30 118.80 126.20 133.40 140.40 147.10 153.40 159.90 SDT 3.09 3.38 3.67 3.96 4.25 4.52 4.77 5.00 561 CO347 =`A . 30 TCG 45.70 43.20 40.60 37.90 35.10 32.20 29.10 25.80 KW 91.70 100.50 109.20 117.90 126.40 134.70 142.80 150.70 SDT 2.78 3.05 3.35 3.67 4.01 4.37 4.73 5.10 35 TCG 49.80 47.10 44.30 41.40 38.40 35.20 31.80 28.10 KW 94.30 102.90 111.50 120.00 128.30 136.50 144.40 152.00 SDT 2.85 3.13 3.43 3.76 4.10 4.46 4.83 5.20 40 TCG 54.20 51.20 48.10 45.00 41.70 38.20 34.50 30.30 KW 96.90 105.40 113.90 122.20 130.30 138.30 146.00 153.20 SDT 2.93 3.22 3.51 3.84 4.19 4.55 4.92 5.29 45 TCG 58.60 55.40 52.10 48.60 45.00 41.30 37.20 32.60 KW 99.60 108.00 116.20 124.40 132.30 140.10 147.50 154.50 SDT 3.02 , 3.30 3.60 3.94 4.28 4.64 5.01 5.37 50 TCG 63.20 59.70 56.10 52.30 48.40 44.30 39.90 34.90 KW 102.40 110.60 118.70 126.60 134.40 141.80 149.00 155.70 SDT 3.11 3.40 3.70 4.03 4.37 4.73 5.09 5.45 55 TCG 67.80 64.00 60.10 56.10 51.80 47.40 42.50 37.20 KW 105.20 113.20 121.10 128.90 136.40 143.60 150.40 156.80 SDT 3.21 3.49 3.79 4.12 4.46 4.81 5.17 5.51 ' '.561 C048 =F TCG 49.30 46.50 43.70 50 30 40.80 37.80 34.60 31.20 27.50 K W 93.80 102.50 111.10 119.70 128.00 136.30 144.30 151.90 SDT 2.80 3.07 3.37 3.70 4.03 4.38 4.74 • 5.09 35 TCG 53.70 50.70 47.70 44.50 41.20 37.80 34.10 29.90 KW 96.50 105.10 113.50 121.90 130.10 138.10 145.90 153.30 SDT 2.88 3.16 3.46 3.78 4.12 4.48 4.84 5.20 40 TCG 58.30 55.10 51.70 48.30 44.70 40.90 36.90 32.30 KW 99.30 107.60 116.00 124.20 132.20 140.00 147.50 154.60 SDT 2.97 3.25 3.55 3.88 4.22 4.57 4.93 5.29 TCG 63.00 59.50 55.90 52.20 48.30 44.20 39.70 34.70 45 KW 102.10 110.40 118.50 126.50 134.30 141.90 149.10 155.90 SDT 3.06 3.34 3.64 3.97 4.31 4.67 5.03 5.38 50 TCG 67.90 64.10 60.10 56.10 51.90 47.40 42.50 37.20 KW 105.10 113.10 121.00 128.90 136.40 143.70 150.70 157.20 SDT 3.16 3.44 3.74 4.07 4.41 4.76 5.11 5.46 55 TCG 72.80 68.70 64.40 60.10 55.50 50.60 45.30 39.80 KW 108.00 115.90 123.60 131.20 138.50 145.60 152.10 158.40 SDT 3.26 3.54 3.84 4.17 4.50 4.85 5.19 5.53 , - r 5 . ,, 61 C060. =H - TCG 62.90 59.20 55.40 51.40 47.20 43.00 38.40 33.30 30 KW 99.60 108.50 117.50 126.40 135.10 142.60 149.80 156.80 SDT 3.57 3.93 4.33 4.76 5.20 5.61 6.01 6.40 TCG 68.50 64.50 60.30 55.90 51.30 46.60 41.60 36.10 35 KW 102.60 111.30 120.10 128.80 137.40 144.70 151.50 158.40 SDT 3.69 4.05 4.46 4.89 5.34 5.76 6.15 6.55 TCG 74.30 69.90 65.30 60.50 55.40 50.20 44.60 39.00 40 KW 105.70 114.20 122.80 131.20 139.60 146.80 153.20 159.90 SDT 3.81 4.18 4.59 5.02 5.48 5.90 6.28 6.67 45 TCG 80.20 75.40 70.40 65.20 59.60 53.70 47.60 42.40 KW 108.90 117.20 125.50 133.70 141.70 148.80 154.80 161.10 SDT 3.95 4.31 4.72 5.15 5.61 6.03 6.41 6.75 TCG 86.20 81.00 75.60 69.80 63.70 57.20 50.60 46.20 50 KW 112.20 120.30 128.40 136.30 143.90 150.80 156.40 161.50 SDT 4.09 4.45 4.87 5.29 5.74 6.16 6.52 6.79 TCG 92.40 86.70 80.70 74.50 67.80 60.60 53.60 54.10 55 KW 115.60 123.40 131.20 138.80 146.10 152.70 158.00 152.80 SDT 4.24 4.61 5.02 5.43 5.87 6.29 6.63 6.30 • ARI listing applies only to systems shown in Ratings and Performance table. SST - Saturated Temperature Entering Compressor (°F) KW - Total Power (Kw) TCG - Gross Cooling Capacity (1000 Btuh) SDT - Saturated Temperature Leaving Compressor ( °F) -29- 1 SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc. 2. Minimum outdoor operating air temperature without low- ambient operation accessory is 55°F (12.8 °C). 3. Maximum outdoor operating air temperature is 125°F (51.7 °C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. 6. For interconnecting refrigerant tube lengths between 50 and 175 ft, consult Residential's Split System Long -Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft. 8. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor. 9. Use only copper wire for electric connection at unit. Aluminum and dad aluminum are not acceptable for the type of connector provided. -30- 1 GUIDE SPECIFICATIONS Air - Cooled, Split- System Air Conditioner 561 C 1 -1/2 to 5Tons Nominal GENERAL Condenser fan motors will be totally enclosed, 1 -phase type System Description with class B insulation and permanently lubricated bearings. Outdoor - mounted, air - cooled, split- system air conditioner unit Shafts will be corrosion resistant. suitable for ground or rooftop installation. Unit consists of a her- Fan blades will be statically and dynamically balanced. metic compressor, an air - cooled coil, propeller -type condenser Condenser fan openings will be equipped with PVC - coated fan, and a control box. Unit will discharge supply air upward as steel wire safety guards. shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Compressor Quality Assurance Compressor will be hermetically sealed. Unit will be rated in accordance with the latest edition of ARI Compressor will be mounted on rubber vibration isolators. Standard 210. Condenser Coil Unit will be certified for capacity, efficiency, and listed in the lat- Condenser coil will be air cooled. est ARI directory. Coil will be constructed of aluminum fins mechanically bonded Unit construction will comply with latest edition of ANSI/ to copper tubes which are then cleaned, dehydrated, and ASHRAE and with NEC. sealed. Unit will be constructed in accordance with UL standards and Refrigeration Components will carry the UL label of approval. Unit will have c -UL approval. Refrigeration circuit components will include liquid line shutoff Unit cabinet will be capable of withstanding Federal Test valve with sweat connections, suction line shutoff valves with Method Standard No. 141 (Method 6061) 500 -hr salt spray test. sweat connections, system charge of R22 refrigerant, and com- Air- cooled condenser coils will be leak tested at 150 psig and pressor oil. pressure tested at 300 psig. Operating Characteristics Unit constructed in ISO 9001 approved facility. The capacity of the unit will meet or exceed Btuh at a Delivery, Storage, and Handling suction temperature of ___ °F. The power consumption at full Unit will be shipped as single package only and is stored and load will not exceed _ kW. handled per unit manufacturers recommendations. Combination of the unit and the evaporator or fan coil unit will Warranty (for inclusion by specifying engineer) have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evapo- U.S. and Canada only. rator at _ °F wet bulb and °F dry bulb, and air enter - PRODUCTS ing the unit at _ °F. Equipment The system will have an SEER of __ Btuh/Watt or greater at Factory- assembled, single -piece, air - cooled air conditioner unit. DOE conditions. Contained within the unit enclosure will be all factory wiring, pip- Electrical Requirements ing, controls, compressor, refrigerant charge (R22), and special Nominal unit electrical characteristics will be ___ v, single features required prior to field start-up. phase, 60 Hz. The unit will be capable of satisfactory operation Unit Cabinet within voltage limits of v to v. Unit cabinet will be constructed of galvanized steel, bonderized, Unit electrical power will be single point connection. and coated with a powder coat paint. Control circuit will be 24v. Fans Special Features Condenser fan will be direct -drive propeller type, discharging air Refer to section of this literature identifying accessories and upward. descriptions for specific features and available enhancements. —31— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Healing &A Cancels PDS 561C.18.6 © 1999 Bryant Heating 8 Cooling Systems, 7310 W. Morns St., Indpls., IN 46231 —32— PRINTED IN U.S.A. Catalog No. 5256 -112 11 -01