Loading...
Permit - 6/9.€(70 - '(.2.,(1 . s.j.4 - , - ; _e_A.Lec .eAt 0 t ,. :::iiirro CI F TIGARD ELECTRICAL PERMIT '_:. COMMUNITY DEVELOPMENT Permit #: ELC2010 -00225 4t.1 GARD' 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 05/07/2010 ,; Parcel: 25111 DB13800 Jurisdiction: Tigard Site address: 15085 SW DAWN CT Subdivision: LAUNALYNDA PARK Lot: 3 Project: Kribs Project Description: Rooftop solar photovoltaic installation. 5/28/10, adding (1) service. Owner: FEES KRIBS, GORDAN J AND LINDA J Quantity Description Date Amount 15085 SW DAWN CT TIGARD, OR 97224 1 crt Branch Circuits 05/07/2010 $56.18 wo /Purchase Service or PHONE: 503 - 620 -9471 Feeder 1 ea 12% State Surcharge - 05/07/2010 $6.74 Electrical Contractor: 1 ea Services or Feeders - 200 05/28/2010 $100.70 PRO STAT SERVICES LLC amps or less 2904 E 24TH STREET 0 ea 12% State Surcharge - 05/28/2010 $12.09 VANCOUVER, WA 98661 Electrical PHONE: 503 - 539 -7772 FAX: 360- 718 -7092 Type of Use: SF Class of Work: ALT Type of Const: Occupancy Grp: Total $175.71 Required Items and Reports (Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTIO. • • -lion law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001 -0010 rough OAR 9 001 -0100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. ` ___d i......2______ Issued By. . Permittee Signature: �c / OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease or rent. OWNER'S SIGNATURE Date: .---" CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' r 1,4�ct.1 Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD ELECTRICAL PERMIT = -, COMMUNITY DEVELOPMENT Permit #: ELC2010 -00225 Date Issued: 05/07/2010 TIGARD' 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 parcel: 2 /07/ D613800 Jurisdiction: Tigard Site address: 15085 SW DAWN CT Subdivision: LAUNALYNDA PARK Lot 3 Project: Kribs Project Description: Rooftop solar photovoltaic installation. Owner: FEES KRIBS, GORDAN J AND LINDA J Quantity Description Date Amount 15085 SW DAWN CT 1 crt Branch Circuits 05/07/2010 $56.18 TIGARD, OR 97224 wo /Purchase Service or PHONE: 503 - 620 -9471 Feeder 1 ea 12% State Surcharge - 05/07/2010 $6.74 Electrical Contractor: PRO STAT SERVICES LLC 2904 E 24TH STREET VANCOUVER, WA 98661 PHONE: 503 - 539 -7772 FAX: 360- 718 -7092 Type of Use: SF Class of Work: ALT Type of Const: Occupancy Grp: Total $62.92 Required Items and Reports (Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR •520 100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. / Issued By: eel/ � Permittee Signature: CAI f/°/' ('�77e/ OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' Date: LICENSE NO. Cali 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Apr 26 01 05:19p Dale Krueger 360- 260 -7064 p.2 Electrical Permit Applica s l r : �rL,� Fo l r � n • , Gi)� ,,,, "< .„ ,..„ , ,, t r " R �, P ���� :. 1o �I 2,M & 1 : &' rr L.. ��; i r k r � �ih'. III . orsve ,� r • '➢NJi 9 l#'�J1L`'.'MJ�`.i"u'�l h�lil IFaAt7P• �' r � � r �' �d� 111 City of Tigar MAY — 6 2010 Dat&B Received Pe rmlNo: ar a �� o Date/By: 5 CO �6 ekCo?O!D -� 13125 SW Hall Blvd., Tigard, OR 9722 plan Review Phone: 503.639.4171 Fax: 503.59& TIGARD Date/By: Other Perm: "' r "' ''' ' Ii Inspection Line: 503.639.417 %.#1 Date Re / 1211 See Page for f1�;AEt °` BUILDING DIVISION sod '�'� wrw +.v¢' i ";Y! Internet: www.tigard-or.gov DIVISION Notified/Method: � � (� Supplemental Information TYPE OF WORK PLAN REVIEW ❑ New construction ® Addition/alteration /replacement Please check all that apply (submit 2 sets of plans w /items checked below): O Service or feeder 400 amps or more ❑ Building over three stories. ❑ Demolition ❑ Other: where the available fault current ❑ Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑ Floating buildings. less to ground, or exceeds 14,000 ❑ Commercial -use agricultural ® I- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building amps for all other installations. buildings. 111 Multi-family 0 Master builder ❑ Other: ❑ Fire pump. ❑ Installation ef75KVAnr JOB SITE INFORMATION AND LOCATION ❑ Emergency system. larger separately derived system. ❑ Addition of new motor load of ❑ °A ", "E ", t -2 "! - ", Job no.: Job site address: 15085 SW Dawn CL I00HP or more occupancy. ❑ Six or more residential units. ❑ Recreational vehicle parks. f City /State /ZIP: Tigard, OR 97224 ❑ Heath -care facilities. ❑ Supply voltage for more than ❑ Hazardous locations. 600 volts notnieal. Suite/bldg. /apt. no.: I Project name: KRIBS ❑ Service or feeder 600 amps or inure. FEE SCHEDULE Cross street/directions to job site: Dacriytfun I city. I Fee 1 Total New residential single- or multi - family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq. ft. or less 1 68.54 4 La. add'. 500 sq. ft. or portion 33.92 I Tax map/parcel no.: Limited energy, residential DESCRIPTION OF WORK (with above sq, ft.) 67.84 2 Limited energy, multi - family Roof top Solar PV installation residential (with above sq. fl.) 67.84 2 Services or feeders installation, alteration, and/or relocation 14 modules 200 amps or less 100.70 2 ® PROPERTY OWNER , 0 TENANT 201 amps to 400 amps 133.56 2 Name: Gordon Kribs - 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Address: 15085 SW Dawn Ct Over 1,000 amps or volts 552.26 2 City/State/ZIP: Tigard, OR 97224 Temporary services or feeders installation, alteration, and /or relocation Phone: (503)620-9471 Fax: ( ) 200 amps or less 59.36 1 Owner installation: This installation is being made on property that l on which is not 201 amps to 400 amps 125.08 2 intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. 401 amps to 599 amps 168.54 2 Branch circuits - new, alteration, or ex tension, r panel Owner signature: Date: A. Fee for branch circuits with ® APPLICANT ❑ CONTACT PERSON above service or feeder fee, each branch circuit 7.42 2 Business name: PROSTAT SERVICES B. Fee for branch circuits without service or feeder fee, first 1 56.18 56.18 2 Contact name: Brandon Krueger branch circuit Each add'I branch circuit 7.42 2 Address: 2904 E 24 Street Miscellaneous (service or feeder not included) Each manufactured or modular City/State /ZIP: Vancouver, WA 98661 dwelling, service an B4 2 dtor feeder Phone: (360) 521 -5742 l Fax: : (360) 718 - 7092 r Reconnect only 67.84 2 E-mail: Pump or irrigation circle 67.84 2 Sign or outline lighting 67.84 2 CONTRACTOR Signal circ or limited - energy Business name: PROSTAT SERVICES panel, alteration, or extension. Page 2 2 Each additional inspection over allowable in any of the above Address: 2904 E 24 Street Additional inspection (1 hr min) I 66.251 hr I I City /State /ZIP: Vancouver, WA 98661 Investigation (I hr min) 66.25/ hr Industrial plant (1 hr min) 78.181 hr (360) 521 -5742 Fax: (360) 718 - 7092 Inspections for which no fee is A specifically listed (% hr min) 90.001 hr ` CCB Lic.: 189902 Electrical Lic.: C597 Suprv. Lic.: 5523S ELECTRICAL PERMIT FEES Suprv. Electrician signature, required: Subtotal: 56.18 � Plan review (25% of permit fee): Print name: Ben Sparlock ea. Date: �, l i •, State surcharge ((2 %ofpermit fee): 6.74 Authorized signatu . ✓ _ • TOTAL PERMIT FEE: 62.92 _41r11 This permit application expires if a permit is not obtained within 180 Print name: Brandon Krueger Date: t O • days after N has been accepted as complete. Nuunber of inspections allowed per permit Apr 26 01 05:19p Dale Krueger 360- 260 -7064 p.4 1 50 25 s u/ Davrr C , , T; -cwc) oP ; 3 ?. - it Co — i 4. 5 o f a'rn i -tor, . �30 wa4-45 cacti €.:,. i.s.j, r i J am! S 5 -- .ihk.r.. for-, C sn (4 r © o ' 1 kn 2 k'4 f - V - v.ss L..,,. ,,..:.., a.� -._ p sys+Rw (vs 4- : 2 5 ! AO (C20" . M f -.1.t.-- 1e,ss�wuv� I T r Iiiiiiiiii I 1 i"-- i 5I' > N) 6 AWG Inverter Ratitrss ti k y J at to rn _ Ili Rail Grounding Inverter Make , c/1 ,4-.. — Utility Service o Inverter Model # 13 t l k f),)f cn Max DC Volt Ratai= (CO V ( Lk' �� Max Power i' 40 C= 'JC X) wV -a f Modules in Series Nominal AC Voltage 240V DC Run ' M Utility Input Max AC Current= ( 7 A 0 -- feet AC Run v inverter ) feet DC Discoruteet M E Modules in Series Ac Disconnect OCPD cQ •"--. + AC ---v r PV Output M DC s r tiIc 1,) -------- OCPD U j Intergrated UL listed DC Grounding' Main Service Panel Intergrated Disconnect Electrode AC Disconnect Ratings Service Panel Ratings Disco JUG Rating = 30A Service Voltage = 240V Voltage Drop Calculations: Disco Volt Rating = 240V Main OCPD Rating = 200V PV Module Rating at STC Assuming: If 06 Vdc 9 A Za3 • ' pc Disconnect Ratings Inverter OCPD Manufacture - jph Amp Rating = - C) A 240 Vac 35 deg. C Disco Amp Rating =30A - ,67 % panel leads qy'` Model # l / c) / %t : )W Disco Volt Rating =600V 690.53 Photovoltaic Power 0 OS %Return to Combiner � Open - Circuit Voltage= 3C, ( V pV Array Information Source Sign on DC Disco .10 % Combiner to DC disco .: 4 # of Modules in Series U RATED CURRENT 3 , q A 4. 4t2,2... °�° Total DC Vdrop o Operation Voltage= V RATED VOLTAGE LIOG V Total AC Run= 1 ` t 7 N of Parallel Cur•cuit 1 MAX SYS VOLTAGE ,Li Re V Max System Voltage= GOO V o NIAfi CURRENT 9,.5 A 0) Lowest Record Temp 0 F Operating Current= 7, q' A Highest Record Temp IQ5 ° F Job Name: Site Address Short- Circuit Current= A Conductor Types: ) S 0Cg S i W or, livv, c. 1 Max Series Fuse (OCPC ) ! r ; ,q Outside- PV wire 12awg MC4 connectors .1_ ; c u v ` O l ii `! t ` ;. ) -' maximum Powel= 2 - 30 W Inside Conduit- THWN -2 10 AWG Generic Photovoltaic System Electrical Diagram 0 , Voc Temp Coeff' 3i %C ALL GROUNDS- 6 AWG For PV Systems under 10kW NATIONAL SOLAR, INC, Apr 26 01 05:18p Dale Krueger 360- 260 -7064 p.1 TELEPHONE: 360-521-5742 503539-7772 + : Tr V s, Ew P,ROS� :�A�T� SERVICES ' EMAII. bbkru90909mait -com �.l' w�wd}5�1 :i�! m� +i tt�� ����pfd� ' 1 ": �ro1 1 ��a lid �'�I`�',�r4,1 6` da ie.kruegenti)conicast.net : ?aa. 6"\° n r`u d�� MAY' " �! `'` "I IV OF TIG141I3 BUILDING DIVISION To DEBBIE Fn in DALE KRUEGER CITY OF TIGARD BUILDING DEPT. Pages: 5 (includes cover) Fac 1-503-598-1960 Date: May 6, 2010 Phone+: 1- 503 -718 -2439 Re: KRIBS JOB ❑ Urgent ❑ For Review ❑ Please Continent X Please Reply ❑ Please Recycle Comments: Hi Debbie: Thanks for your time on the phone today. You were very helpful. Please find 4 pages following this cover which include Electrical permit app, Credit Card authorization form, and required drawings and wire diagram. Just let me know if you need anything else. Regards. Dale