Loading...
Permit -r- ,Y4 BUILDING PERMIT Ti 9 CITY F TICj RD PERMIT #: BUP2008 -00024 .i, COMMUNITY DEVELOPMENT DATE ISSUED: 2/20/2008 R R ',"[...119„.A D 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S135DD-05200 SITE ADDRESS: 11708 SW WARNER AVE ZONING: C - SUBDIVISION: HOFFARBER TRACTS NO.2 LOT: 035 JURISDICTION: TIG PROJECT: MIRAGE MINI STORAGE Project Description: Fire sprinkler system. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N sf N: S: E: W: OCCUPANCY GRP: Si TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 90 BASEMENT: sf AREA SEP. RATED: STOR: 3 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: N MEZZ ?: N REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: N PARKING: VALUE: $ 76,058.00 Owner: Contractor: MIRAGE STORAGE LLC WYATT FIRE PROTECTION INC. 9055 SW BEAVERTON - HILLSDALE HW 9095 SW BURNHAM PORTLAND, OR 97225 TIGARD, OR 97223 Phone: Contact #: PRI 503 - 684 - 2928 FAX 503 - 684 - 9657 Reg #: LIC 64077 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 1/30/2008 $496.30 [TAX] 12% State Surch 1/30/2008 $59.56 [FLS] FLS Pln Rv 1/30/2008 $198.52 Total $754.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OU • c� g 503.246.6699 or 1.800.332.2344. 1.0.-- 1►'` / Issued By: i v � Permittee Signature: �, e--- ,- Call 503.639.4175 by 7:00 a.m. for an inspection at business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Fire Protection System Building Permit Appli •, 1 r C EIVED FOR OFFICE USE ONLY City of Tigard ��pp �� �� Received { III 13125 S W Hall Blvd., Tigard, OR�4r2fl33 O 20 , Dar /e _ "" 0.--• 0 , s e• ''. ♦- 0. A: --49a9 Q6 . Pla Re �� � ' /�� Phone: 503.639.4171 Fax 503.598.1960 Date/!, X1 4(Ii1 r8 TIGARD Inspection 1,-- ma Line: 503.639.401 OF TIGARD Dat: ' •':y: Juris: 2 See Page 2 for Internet: Line: gard - or. Notified/Method:p( L Supplemental Information �UI.LDING DIVISION 1,0 ( • , 0 ul,,LY-- TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING — ❑ New construction ❑ Demolition Perm fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ` Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ I- and 2- family dwelling 'Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:'' -7 L/O 5; I j 1/� eu y e,y- , u New dwelling area: square feet City/State /ZIP: I,- 0 e_ " j .. 2....z3 Garage /carport area: square feet Suite/bldg. /apt. no.: project name: PAir 5+ 7Jy 7 Covered porch area: square feet Cross street/directions to job site: CJ Deck area: square feet Other structure area: square feet REQUIRED DATA: COMiMERCIAL - USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. / ` 1' I) ∎A A. JIB aft, Valuation: $ �7 , 0 , J O SAM_ Existing building area: square feet New building area: square feet ice' PROPERTY OWNER I ❑ TENANT Number of stories: Name: fY1 l r—ei6 \J 0 y ..5 / L Z Type of construction: Address: Occupancy groups: City/State /ZIP: Existing: Phone: ( ) Fax: ( ) New: a APPLICANT ❑ CONTACT PERSON NOTICE Business name: See_ All l contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City/State/ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) Fax::( ) E -mail: CONTRACTOR BUILDING PERMIT FEES* I U'V l I t ` , ,� `(�JI _ F- p 4- O � Tor (Please refer m fee schedule) Business name: 1J�f r 4 ' l 30 Sr (n Permit fee: Address: - 1 0 G/ 5 � B ,L-r i r' 5`0 City/State /ZIP: — FL) rd Oit 9 7 2 2 State surcharge /o of permit fee): q `� FLS plan review (40% of permit fee): p sJ Z Phone: 5,'3 Li_ 2 Z � Fax: (53) 10 — q ( D 517 (Due upon application.) ) p . CCB lie.: /„ Lie Total permit fees: '7 5i. 3' � tvv Amount received: Authorized signatur (otr-/-7may/ �� This permit application expires if a permit is not obtained Print name: A ' 4 - / l Date: ,/ " - 05 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Service Board. I: \Building \Permits \FPS- PermitApp.doc 03/23/06 4404613T(1I/02/COM'WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ❑ 1 -10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ '7 , � 05 B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $187.50 2,001 to 3,600 $232.50 3,601 to 7,200 $292.50 7,201 and greater $381.50 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ '7 111'7 8 °% Permit fee based on project valuation (see fee schedule): $ Imo. Permit fee based on square footage (see D above): $ State Surcharge (8% of permit fee): $ 5 5� FLS Plan Review (40% of permit fee): $ ) q'. SZ TOTAL: $ r] 5-4/ 3� Plan review requires a completed application and 2 sets of plans at submittal. Plan review fees are required at submittal. "New" fire protection systems require that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICFT level "3" technicians. http: / /w \v\ .ci.tigard.or.us /city_hall/ departments /cd /dots /FpS- Permit; \pp.doc =1=.-:-.:÷r. ` - ,4 FIRE PROTECTION, INC. G 9095 S.W. Burnham 0 Tigard. OR 97223 � 7 0 (503) 6842928 �lJ" b November 21, 2007 TO: Saj Jivanjee RE: Mirage Storage To Whom It May Concern: The attached water flow information was the result of hydrant flow tests performed on 11/13/07. Wyatt Fire Protection performs hydrant flow tests in TVF&R jurisdiction on a regular basis. As required by TVF&R, we contact them before performing any flow test so they can witness the test. 95% of the time Ryan Smith will witness these tests, but in this case (and a few others in the past) he did not as he was out of the office on vacation. Please let me know if you have any questions regarding the test or test equipment. Thank you, Ken Sutherland Wyatt Fire Protection HYDRANT FLOW REQUEST FORM PROJECT: / tie .e Am; S - la ra ' ADDRESS: !17'I© _SCA/ ( dri" -ter- - 177 0' ,- CROSS STREET: Y qGcI HYDRANT LOCATION: 1/7q4 .4f,/ ekir9ro er RESIDUAL: GPM: J (ico 6pti., W DATED: /1 HYDRANT LOCATION: ° 99 (J G) o-r r t,= Ave STATIC: S s RESIDUAL: GPM: 'I6 'Im 6?"`"" 1 7-Q` Z DATED: 90- Water Availability Curve 80- ® .. -1, 70 -- - �� 80- - - '. . c 50 -- �.,-, 40 — \\ 30, 20 \-1 1 10 - J � r i 600 1000 1500 2000 2500 3000 3600 4000 4500 5000 I ® Static = 85 psi. Flow (GPM) M System demand = 20.00 psi with 4640.0 gpm flowing. n Residual is 80 psi at a flow of 1180 gpm. Pressure available = 20.02 psi when 4640.0 gpm Is flowir Demand is below curve by 0.20 psi (0.10%). This form is recognized by most Building Departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. ppr BUILDING DIVISION e rk�4y�'�f 7hC.AR'�' TRANSMITTAL LETTER TO: OL� DATE RECEIVED: DEPT: BUILDING DIVISION H ` , , FROM ITY OF TIGARb d 3! WING DIVISION COMPANY: / • / t ' r0 "� - PHONE: � 6S`t", 9o,g RE: 1(70'S . ) (- 0-0-e_ u Along -.0ex)c/ (Site Address) (Permtt/fase umber) 'roject name or iF.. tvtston name an. o ATTACHED ARE '1 FOLLOWING ITEMS: Copies: Descrip on: 1 ies: De ription: Additi * nal set(s) of plans. ' -visions: Cross .ection(s) and details. all bracing and /or lateral analysis. Floor /■oof framing. Basement and retaining walls. Beam t alculations. Engineer's calculations. Other (: plain): REMARKS: , ) .a, I� FOR OFFIC U .E ONLY Routed to Permit teta Date: 7 Initi Ar Fees Due: ❑ e o Fee Description: Amount'Due: $ $ Special Instructions: Reprint Permit (per PE): Ti Yes 1O n Done Applicant Notified: Date: 77A r I J Initials: l: \Building\ Forms \Transmittal Letter- Revisions .doc 4/4/07 CITY OF TIGARD Aii BUILDING DIVISION r PERMIT #: BUP2008-000)A 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 2120/2000 Phone: (503) 639 -4171 d I � m 1 Inspection Requests (24 Hrs.): (503) 639 -4175 "IL. INSPECTION WORKSHEET FOR DATE: 10/31/2008- TIME: 7 :00AM PAGE: 30 SITE ADDRESS: 11708 SW WARNER AVE CLASS OF WORK: SUBDIVISION: HOFFARBER TRACTS NO .2 LOT #: 035 TYPE OF USE: PROJECT NAME: MIRAGE MINI STORAGE DESCRIPTION: Fire sprin44er system. OWNER: MIRAGE STORAGE l.LC, PHONE #: CONTRACTOR: WYATT FIRE PROTECTION INC. PHONE #: 603-684-2928 Inspection Request Scheduled For: Date 10/31/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 077464 -01 603.684 -2928 N C 00 3 1%.4 Corrections /Comments /Instructions: 1I T — • tP RC? v (. C (F161-) 14 PP>+ i! MI_ . — 3 i L - 0 __ A Lo PAS I] PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL �'/ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED / .-- 2 l ,c Inspector: A Date: its 2 I ! Ug Phone #: (503) 718- ■Lf ` + Oct 31 08 01:50p WYATT FIRE 5036849657 p.2 AUTOMATIC 3.U�o 0 2 � FORM 2 -J • SPRINKLER SY STEMS (Page 1 of 2) CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractors representative and witnessed by an owner's representattve. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for a It is understood the owner's representative's signature In no way prejudices any claim against contre or for faulty material, or failure to comply with approving a uthority's requirements or local ordinances, PROPERTY NAME I I a e- f 6 6 c /' P ROPERTY AD'. RESS _ S - o8 ACCEPTED BY APPROVING AUTHORITY('$) NAMES •J C7 ADDRESS PLANS INSTALLATION CONFORMS 70 ACCEPTED PLANS EQUIPMENT USED IS APPROVED YE NO IF NO, EXPLAIN DEVIATIONS ❑ YES p NO HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE A MAINTENANCE OF THIS NEW EQUIPMENT IF NO, EXPLAIN YES NO INSTRUCTIONS HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS AND NFPA 13A BEEN LEFT ON PREMISES IF NO, EXPLAIN ❑YES NO LOCATION SUPPLIES BLOCS. • OF SYSTEM • MODEL MA ORIFICE OU TEM PERATURE Tv O SIZE RATING SPRINKLERS ) S T RATING EMIIIIIMMIIMII PIPE CONFORMS TO I _r_ /3 STANDARD PIPE AND FITTINGS CONFORM TD (! J�1 AYES n NO FITTINGS I F NO, EXPLAIN Ir l STANDARD ® YES NO ALARM ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE VALVE • OR FLOW MODEL MIN. DGJ • + INDICATOR ` 5=L DRY VALVE MODEL SERIAL NO. O "D.O" ■ MAKE MODEL SERIAL NO. 1 rETOTRWA.rER AIR TRIP POINT TIME W� ALARM TEST PIPE PRESSURE PRESSURE AIR PRSURE REACHED OPERATED DRY PIPE ® TEST OUTLET PROPERLY _ OPERATING PSI PSI MIN. SEC. YES NO TEST Without O.O.O. 1 L.t �7 With ! L ( MI O.O.D. � - � IF NO, EXPLAIN ' MEASURED FROM TIME INSPECTOR'S TEST PIPE IS OPENED. . O ct 31 08 01:50p WYATT FIRE 5038849657 p.1 TIC = �p FORM 2 -J AUTOMATIC ((Page 2 of 2) SPRINKLER SYSTEMS i toe k... 2 pa OPERATION PNEUMATIC O ELECTR IC ❑ HYDRAULIC PIPING SUPERVISED O YES ONO [DETECTING MEDIA SUPERVISED O YES ONO ODES VALVE OPERATE F ROM THE MANUAL TRIP AND /OR REMOTE CONTROL STATIONS OYES O NO DELUGE & 15 THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO, EXPLAIN PREACTION O YES ONO VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAXIMUM TIME TO SUPERVISION LOSS ALARM OPERATE VALVE RELEASE OPERATE RELEASE MAKE MODEL YES NO YES NO MIN. 1 SEC. H YDROSTATIC: Hydrostatic tests shall be made at not lass than 200 psi (13.6 bars) for two hours or 50 psi 13.4 bars) aoove sonic pressure in excess of 150 psi (102 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. TEST FL SHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as DESCRIPTION hydrants and blow-offs. Flush at flows not lass than 400 GPM 11514 Umin) for 4-inch pipe, 600 GPM 12271 L /min) for 5-inch pipe, 750 GPM (2839 L/min} for 6-inch pipe, 1000 GPM (3785 Umin) for 8-inch pipe, 1500 GPM (5678 L /min) for 10.inch pipe and 2000 GPM (7570 L /min) for 12 -inch pipe. When supply cannot produce stipulated flow rates, obtain maximum available. PNEUMATIC: Establish 40 psi 12.7 bars) air pressure and measure drop which shall not exceed 1 -4 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-15, psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT ) nil PSI FOR D - HRS. IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED OYES ONO EQUIPMENT OPERATES PROPERLY • OYES ONO DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE: RESIDUAL PRESJRE WITH VALVE IN TEST PIPE OPEN WIDE TESTS TEST STATIC PRESSURE: - PSI PSI Underground mains and lead in connections to system risen flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE U FORM NO. 85B O YES O NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER- GROUND SPRINKLER PIPING ❑ YES ❑ NO BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS WELDED PIPING ! YES ONO IF YES ... 00 YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS.OF AT LEAST AWS 010.9, LEVEL AR -3 OYES ONO - DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS 010.9, LEVEL AR -3 JE YES 0 NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE'SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF 1YES O NO PIPING ARE NOT PENETRATED HYDRAULIC NAMEPLATE PROVIDED IF NO, EXPLAIN DATA NAMEPLATE CI YES O NO DATE LEFT IN SERVICE WITH ALL. CONTROL VALVES OPEN: REMARKS NAME OF SPRINKLER CONTRACTOR W YA T I !{. 1)r Tern, i TESTS WITNESSED BY SIGNATURES FOR P•OPERTYpWNER (SIGNED) TITLE , DATE • R S r RI LE ICON RAC OR ( rG 0) TITLE (� -�,j / • D • � T f E ADDITIONAL EXPLANATION AND NOTES CITY aOF TIGARD , iiiii BUILDING DIVISION PERMIT #: Q311P ?008 OC10. 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 2/20/2008 Phone: (503) 639 -4171 l Inspection Requests (24 Hrs.): (503) 639 -4175 °- — INSPECTION WORKSHEET FOR DATE: 10/29/2008 TIME: 7:00AM PAGE: 22 SITE ADDRESS: 1 1708 SW WARNER AVE CLASS OF WORK: SUBDIVISION: HOFFARBER TRACTS NO.2 LOT #: 03; TYPE OF USE: PROJECT NAME: MIRAGE MINI STORAGE DESCRIPTION: Fire sprinkler system. OWNER: MIRAGE STORAGE LLC, PHONE #: CONTRACTOR WYATT FIRE PROTECTION INC. PHONE #: 503 -684 -2928 Inspection Request Scheduled For: Date 10/29/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 999 Sprinkler final 077316 -01 503-684-2928 N Corrections /Comments /Instructions: 46 p K. v , .--- /..t /7- (-> 4- / .-. e_40 .---t. e____ c...-- i f L i __46--...;1% 7 4 ,„--:- -g_.,...:34„-- \,/ - ...L.. -1, ,.._...,..-t PC.— . I - • k CZST ❑ PASS . PARTIAL APPROVAL El CANCEL El NO ACCESS i i r I A � ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: r 'e ) Z- b13 Phone #: (503) 718- Z-o CITY OF TIGARD BUILDING DIVISION •: - '~ PERMIT #: BUP200B Op0t4 13125 SW Hall Blvd., Tigard, OR 97223 `' DATE ISSUED: 2/20/2000 Phone: (503) 639 -4171 Z Inspection Requests (24 Hrs.): (503) 639 -4175 R 'I I.. INSPECTION WORKSHEET FOR DATE: 8/11/2008 TIME: 7:01AM PAGE: 14 SITE ADDRESS: 1'1706 SW WARNER AVE CLASS OF WORK: SUBDIVISION: FIOFFARBFR TRACTS NO.2 LOT # 035 TYPE OF USE: • PROJECT NAME: MIRAGE MINI STORAGE DESCRIPTION: Fire sprinkles system. OWNER: MIRAGE STORAGE LLC, PHONE #: CONTRACTOR WYA FIRE PROTECTION INC. PHONE #: 505.684 -2928 Inspection Request Scheduled For: Date: 8/11/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 910 Sprinkler rough -in /test 074012 -01 503 -680 -9690 N Corrections /Comments/ Instructions: ., II - . - A - 4 , ' AIIIIIE d° 7c 1 f .M_A. A91+ o-t 7 . 1(T c- c— e S c:-1 fi r. _ ❑ PASS , l05 _ - ' • _ •-_ ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR, INSPECTION ❑ ADDITIONAL FEES ASSESSED 6 ...„ ,, Inspector: .. Date: 11 Phone #: (503) 718 - ley CITY OF TIGARD , BUILDING DIVISION PERMIT #: BUP2008-00024 13125 SW Hall Blvd., Tigard, OR 97223 " DATE ISSUED: 2/2.0/2008 Phone: (503) 639 -4171 pI�� Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 9/24/2008 TIME: 7 :00AIv1 PAGE: 42 SITE ADDRESS: 11708 SW WARNER AVE CLASS OF WORK: SUBDIVISION: HOFFARBER TRACTS NO.2 LOT # 035 TYPE OF USE: PROJECT NAME: MII•ZAGE MINI STORAGE DESCRIPTION: Fire sprinkler system. OWNER: PHONE #: CONTRACTOR: MIRAGE STORAGE LLC PHONE #: 1NYAT FIRE PROTECTION INC. 503-6134-2928 Inspection Request Scheduled For: Date: 9/24/2 008 Pour Time: Code # Inspection Description Confirm # Contact # Message 920 Suppression trip test 075829.01 503 -684 2928 � Corrections/Comments/Instructions: 1■49g, - TM ? CO X4 i t )1 t_— • 'cam if--c, C Z�� / — / IS / � 6 r ce--/ aV/ cr si Z.5 1/ A- S P( PP d�O \./ (... sC b fr...--1.7 pc0 s l l ei _ 'Tr, A/, 4WIIWIll - /VU 2Ev/ S / o S .' J- �_ , (i e--'71 ) - Z /off Z f Afia y; � /1 PARTIAL APPR• , • CAN El NO ACCESS rA IL �\ % CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED f . , Inspector: Date: 7 zs as Phone #: (503) 718- e