Permit is CITY TIGARD PLUMBING PERMIT DEVELOPMENT SERVICES PERMIT #: PLM2006 -00361 I I ' 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 DATE ISSUED: 9/6/2006 PARCEL: 1 S12600 -00300 SITE ADDRESS: 09522 SW WASHINGTON SQUARE RD H -7 ZONING: C -G SUBDIVISION: WASHINGTON SQUARE LOT: JURISDICTION: TIG Project Description: TI - other fixture is (1) drinking fountain. CLASS OF WORK: ALT GARBAGE DISPOSALS: MOBILE HOME SPACES: TYPE OF USE: COM WASHING MACH: BACKFLOW PREVNTRS: OCCUPANCY GRP: M FLOOR DRAINS; 1 TRAPS: STORIES: WATER HEATERS: 1 CATCH BASINS: FIXTURES LAUNDRY TRAYS: SF RAIN DRAINS: SINKS: 1 URINALS: GREASE TRAPS: LAVATORIES: 1 OTHER FIXTURES: 1 TUB /SHOWERS: SEWER LINE: ft WATER CLOSETS: 1 WATER LINE: ft DISHWASHERS: RAIN DRAIN: ft Owner: FEES WASHINGTON SQUARE LLC Description Date Amount BY THE MACERICH COMPANY 9585 SW WASHINGTON SQUARE RD [PLUMB] Permit Fee 7/26/2006 $99.60 TIGARD, OR 97223 [TAX] 8% State Surcha 7/26/2006 $7.97 Phone : 503- 639 -8865 Total $107.57 Contractor: MODERN PLUMBING 11120 SW INDUSTRIAL WAY TUALATIN, OR 97062 REQUIRED ITEMS AND REPORTS Contact # : PRI 503- 691 -6166 FAX 503- 691 -6771 Reg #: LIC 87906 PLM 34 -250PB This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 0001 -0010 through OAR 952 - 0001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. Issued By: j �'/��i Permittee Signature: Call 503 - 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Jul 25 06 12:12p MODERN PLUMBING 503 691 6771 p.2 9 ,,.,. kl t ,, ,, p . ‘ Plumbing Permit Applicatio Y- i „441 �' z k o fi o'FFice L ie � L � v r. spa City of Tigard JUL 2 5 200' Received eiB �� ; 0 ' Perm No_: ' N eeio �6 �is 13125 SW Hall Blvd., Tigard, OR 97223 (/ Plan Review Phone: 503.639.4171 Fax: 503.598.1960 ^ J M G � ' 1 Date /By- Other Gf!' l} 24- Flour fns ection Line: 503.639.4175 ., it t . I Internet: www.ci.tigard.or.us .� a iii,... 7c Date Ready /By: /i H See Page 2 for g - � - v. - 1 - ,. : Ni . ; . .. t Notified/Method: y a` Gi d 51.52 for each additional TYPE W ORK FEE. SCHEDULE ❑ New construction ❑ Demolition For special information use checklist Description 1 Qty. 1 Ea. I_ Total ,® Addition/alteration/replacement ❑ Other: New 1-2-family dwellings (includes 100 ft. for each utility connection) • CATEGORY OF CONSTRUCTION SFR (l) bath 249.20 0 1 -and 2- farnily dwelling ,81 Commercial/industrial SFR (2) bath 350.00 ❑ Accessory building 111 Multi-family SFR (3) bath 399.00 Each additional ball kitchen 45.00 ❑ Master builder ❑ Other: Fire sprinkler ( sq. ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities Job site address: a5 ZZ 5 uJ UJQSt,t . _ R Catch basin or area drain 16.60 City /State/ZIP: i 9 a r Q ( 2 , 9 -7 2 3 Drywell, leach line, or trench drain 16.60 Footing drain (no. linear ft.: ) , Page 2 Suite/bldgJapt. no.: P roject name: E ; ' au. -r j Manufactured home utilities 110.00 Cross street/directions to job site: I Manholes 16.60 Rain drain connector 16.60 Sanitary sewer (no. linear ft.: ) Page 2 Storm sewer (no. linear ft.: ) Page 2 Subdi .ision: /3/ $ n (} - w 3, Lot no.: Water service (no. linear ft.: ) Page 2 Tax map /parcel no.: Fixture or item Absorption valve 16.60 DESCRIPTION OF WORK Bacldlow preventer Page 2 1 e no- in+ 1 ran J futfe.� -' ei -1 Backwater valve 16.60 II Clothes washer 16.60 Dishwasher 16.60 ❑ PROPERTY OWNER I ❑ TENANT Drinking fountain 16.60 (o. fpD Ejectorsisump 16.60 Name: Expansion tank 16.60 Address: Fixture/sewer cap 1 16.60 City/State/ZIP: Floor drain/floor sink/hub 1 16.60 ; /l� rtr0 Phone: ( ) Fax: ( ) Garbage disposal 16.60 ❑ APPLICANT ❑ CONTACT PERSON Hose bib 16.60 Ice maker 16.60 Business name: Interceptor/grease trap 16.60 Contact name: Medical gas (value: $ ) Page 2 Address: Primer 16.60 CityJStatetLIP: f dra Heal) 16.60 ( I ( ) Si , asi avatory 2 16.60 13 ZO Phone: ) Fax: : Sub /shower /shower pan 16.60 E -mail: Urinal 16.60 CONTRACTOR Water closet ' 16.60 f ( (, O Business name: )\Ode ( jr) P ` u yv‘. 6 t .-c eu Water heater i 16.60 ( (, ( 0 Address: 1 2 5L..1...) (hd u S` - r { 2- L Other: City/State /Z1P: Tea t t� -nom 0/Z 9-lot'z Subtotal -- ! Minimum permit fee: $72.50 99• � 0 Phone: ( 09 I G (o, Fax: (50 ) 69 ! ( J Residential backflow minimum permit fee: $36.25 CCB Lic.: R -7 Gi C � umbing Lic. no.: 3 Li _ 7. C ! l Authorized signature: y b � / (D State surcharge (8% TOTAL permit fee) � - j� �[/v�/L� / TOTAL PERMIT FEE ' Print name: De_lo k_,.. C� ea I Date: - 7- L[}- This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri -Coun wilding Industry Service Board. I:t BulldinglPermiis tPLM- PcrmitApp. C6/0 440- 4516T(10:02/COM/WEa) 6-7 70- L, #,/0.7 Accumulative Sewer Tally Parcel # 1S12600 -00300 Tenant Name: Eddie Bauer This SW R# 2006 -00159 Site Address: 9522 SW Washington Sq Rd This PLM# 2006 -00361 Fixture Value Previous Previous Credits Capped Fixture Fixture New New # value capped off value added added total total count off #s count # value #s values Baptisery/Font 4 0 0 0 0 0 Bath - Tub /Shower 4 0 0 0 0 0 - Jacuzzi/Whirlpool 4 0 0 0 0 0 Car Wash - Each Stall 6 0 0 0 0 0 - Drive through 16 0 0 0 0 0 Cuspidor/Water Aspirator 1 0 0 0 0 0 Dishwasher - Commercial 4 0 0 0 0 0 - Domestic 2 0 0 0 0 0 Drinking Fountain 1 0 0 1 1 1 1 Eye Wash 1 0 0 0 0 0 Floor Drain /Sink - 2 inch 2 1 2 1 2 1 2 1 2 - 3 inch 5 0 0 0 0 0 - 4 inch 6 0 0 0 0 0 - Car Wash Dr 6 0 0 0 0 0 Garbage Disposal - Domestic (to 3/4 HP) 16 0 0 0 0 0 - Commercial (to 5 HP) 32 0 0 0 0 0 - Industrial (over 5 HP) 42 0 0 0 0 0 Ice Machine /Refrigerator Drain 1 0 0 0 0 0 Oil Sep (Gas Station) 6 0 0 0 0 0 Rec. Vehicle Dump station 16 0 0 0 0 0 Shower - Gang (per head) 1 0 0 0 0 0 - Stall 2 0 0 0 0 0 Sink - Bar /Lavatory 2 1 2 1 2 1 2 1 2 - Bradley 5 0 0 0 0 0 - Commercial 3 0 0 0 0 0 - Service 3 0 0 1 3 1 3 Swimming Pool Filter 1 0 0 0 0 0 Washer - Clothes 6 0 0 0 0 0 Water Extractor 6 0 0 0 0 0 Water Closet - Toilet 6 1 6 1 6 1 6 1 6 Urinal 6 0 0 0 0 0 Previous EDU Count 0 0 Capped EDU Credit 0 TOTALS 3 10 3 10 5 14 5 14 Current Fixture Value 14 divided by 16 = 0.9 Current EDU 1 EDU = $ 2,700 Previous Fixture Value 10 divided by 16 = 0.6 Previous EDU Change 4 divided by 16 = 0.3 over (under) $ 810.00 Enter EDU Change Here 0.3 Notes: Authorized Name /Signature: Debbie ' •am- r�'i�� Date: 7/26/2006 "' g Division Note: The property owner shall retain the ORIGINAL sewer tally record. If credits exist, this document will serve as a voucher which must be submitted to the City of Tigard Building Division to redeem credits towards future system development charges. i:\Building\Sewer Tally \SewerTallySheet.xls 7/1/06 Sep 14 06 03:14p Grey Wolf HVAC 3603262844 p.l Oh 1.bv CX� Carey Wolf BlfVAC, IINC, certified MBE contractor 120 4012 NE 120 Street, Vancouver, WA 98686 E - mail: dosbometc�GREYWOLFHVAC.COM �� `' Cell: 503 -341 -0891 Fax: 360 -326 -3844 ifs,! J�I + � c fii,v To Val C/o City of Tigard Bldg. Dept. From: Darrell Osbome Fa:c 503 - 624 Pages: 7 pages including cover Phone: 503 -718 -2436 Date: 9/14/2006 Re: Eddie Bauer ©Washington Square CC: file ❑ Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle O Comments: Attached is the submittal we received from the owners after the project had begun. Unit weights are circled with an arrow. This is all Grey Wolf HVAC, INC. currently has in documentation of these products. Please let us know if we could offer more. Best regards, Sep 14 06 03:15p Grey Wolf HVRC 3603262844 p .2 ptvy1 .003c9.- Tag Data - Variable Air Volume Fan Powered Terminal Units (Qty: 4) item Tag(s) Qty Description Model Number Al VAV -1 1 VAV Fan Powered Terminal Units VPEF1407SQ A2 VAV -2 1 VAV Fan Powered Terminal Units VPEF1407SQ A3 VAV -3 1 VAV Fan Powered Terminal Units VPEF1407SQ A4 VAV-4 1 VAV Fan Powered Terminal Units VPEF1005SQ Product Data - Variable Air Volume Fan Powered Terminal Units All Units Parallel with electric heat 208 volt, 3 phase 1/2" [13mmj matte faced insulation 2 stages of heat - equal increments Slip and drive connection 24 volt magnetic contactors Single speed motor w/ SCR Disconnect switch DDC with on /off electric heat control Electric heater air flow switch Left hand connection 1 Digital display zone sensor (Fld) Power fuse Item: Al, A2, A3 Qty: 3 Tag(s): VAV -1, VAV -2, VAV-3 14" (356 mm) inlet size 07 super quiet fan 208/60/1 motor voltage 12.0 kilowatt Item: A4 Qty: 1 Tag(s):. VAV-4 10" (254 mm) inlet size 05 super quiet fan 115/60/1 motor voltage 7.0 kilowatt Performance Data - Variable Air Volume Fan Powered Terminal Units Tags VAV -1 VAV -2, VAV-4 VAV-3 Design cooling airflow (cfm) 2190 2120 1000 Min cooling airflow (cfm) 408 408 215 Valve heating airflow (cfm) 408 408 215 Cooling inlet diameter (in) 14.000 14.000 10.000 Cooling inlet velocity (ft/min) 2049 1983 1833 APD @ cooling airflow (in H2O) 0.04 0.04 0.04 Fan airflow (cfm) 1782 1712 785 Downstream SP (in H2O) 0.25 _ 0.25 0.25 Fan TSP (in H2O) 0.27 0.27 0.26 % of fan range ( %) 81.00 74.00 36.00 Fan power (hp) 1.000 1.000 0.500 Plenum EAT (F) 75.00 75.00 75.00 - : 1I - a ED F) , �.-,_55.00 _ 55j`,,, _ „i'.! A, .444(7, O•eratin• wei• lb 164.0 154.0 12;.0 Unit heating a irflow (cfm) 11.----- 190 212 'To i Coil heating capacity (MBh) 40.98 40.98 23.90 Room heat Toss (MBh) 39.25 39.03 22.49 Room heating setpoint (F) 72.00 72.00 72.00 Coil EAT (F) 71.27 71.15 70.70 Unit LAT (F) 88.52 88.97 92.73 Coil LAT (F) 88.52 88.97 92.73 Full Toad amps (A) 39.91 39.91 26.13 Min circuit ampacity (A) 49.89 49.89 32.66 Max overcurrent protection (A) 50.00 50.00 35.00 Electric heater kW (kW) 12.00 12.00 7.00 Sep 14 06 03:15p Grey Wolf HVEC 3603262844 p.3 ,.w '1p111Y01 Vr/ — Vet IMUM s111 V •IYIIIG tams 1 C.Y I llll1lUI %roma Item: Al - A4 Qty: 4 Tag(s): VAV -1, VAV -2, VAV-3, VAV-4 General Unit Information Casing - The unit casing is 22 gauge galvanized steel. Outlet duct connection is flanged. --. Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided. Filter - A filter is provided on the plenum inlet. Agency Listing - UL and Canadian UL listed as environmental air terminal unit. UL Control #9N65. All Trane terminal units are ARI 880 -98 certified. General Unit Clearance Leave a minimum of 36" on control box side of unit for adequate service access. Allow at least 12" on remaining sides for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. 1/2" Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1/2 ", 1.8 lb/cu. ft composite density glass fiber with high density facing. The insulation is UL listed and meets NFPA -90A and UL 181 standards. Ali insulation options will meet the 25/50 smoke developed and flame spread rating (per ASTM E 84 and UL 723 and CAN /ULC S102 -M88) Meets NFPA- 90B. The insulation R -value is 1.9. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve 8, Fan Description (Parallel) (Series) The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring airflow within +l- 5% of unit cataloged airflow. Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft which rotates in a self lubricating bearing. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. Air valve leakage <1% at 4 ". 1005SQ Air Valve/Fan Combination Size (Parallel) 10" Inlet designed for up to 1400.0 cfm. Fan is 1550.0 cfm for Std Motor and 1850.0 cfm for ECM Motor. 1407SQ Air Valve/Fan Combination Size (Parallel) 14" Inlet designed for up to 3000.0 cfm. Fan is 2025.0 cfm. Motor Single Speed, direct drive induction, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR which is standard. Motors will accommodate anti - backward rotation at start up. Motor and Fan assembly are isolated from terminal unit. Transformer The 50 VA transformer is factory mounted in the fan control box to provide 24 VAC for controls. Fuse Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided. SCR- Variable Fan Speed Control Switch The SCR speed control device allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact CFM requirements. Electric Heat Coil Factory provided and mounted. UL recognized, resistance open -type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel-chromium. The heater terminal box is provided with 7/8" knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan- powered units with electric reheat are single -point power connections. For 480 volt 3 phase and 575 volt 3 phase heaters a 4 wire (includes neutral) power supply is required. Sep 14 06 03:15p Grey Wolf HVAC 3603262844 p.4 Electric Heat Coil -- Z ✓ t0 5" Factory provided and mounted. Resistance open -type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is provided with knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan- powered units with electric reheat are single -point power connections. For 480 volt 3 phase and 575 volt 3 phase heaters a 4 wire (includes neutral) power supply is required. Magnetic Contactor An electric heater 24 volt contact for use with Direct Digital Control (D.D.C.) or Analog Electronic VAV Controls. Power Disconnect Switch (for VSEF & VPEF) A factory provided interlocking door disconnect switch located on the electric heater control panel. Airflow Switch An air pressure device designed to disable the heater when the unit fan is off. Power Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. The drive sides are straight flanges which form a "U" shape. The mating ductwork has a similar setup. The two top and bottom pieces are shaped like a compressed "S" with sealant in the hollow of the "S". These pieces will slide over the top and bottom straight flanges. The top and bottom flanges of the mating ductwork will slide into the otherside of these pieces. The two side pieces are shaped like a "C" and are called "Drives ". These pieces will slide over the "U" shaped flanges so the connection can not be pulled apart. These pieces are usually hammered into place. No screws are required, and by removing the drives, the ducts may be disconnected. D.D.C. Actuator Trane 3 wire, 26 GA, 3.4 VA, 1.7W, 24 VAC, 50/60 Hz. with floating point control actuator with linkage release button. Running torque is 35 in-lb minimum and is non -spring retum with 90 second drive time. Travel is terminated by end stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall when Trane controls are not provided. An integral 3 screw terminal is provided for field wiring. Operating temperature 32.0 F to 125.0 F. Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a proportional integral control algorithm and direct control technology. The controller monitors zone temperature set points, zone temperature and its rate of change, and valve airflow, using a differential pressure signal. Optionally, the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller and pressure transducer are installed and factory wired in an enclosure with 7/8" knockouts for remote control wiring. A Trane zone sensor is required. System Communications The Controller is designed to send and receive data from a Central Control Panel or other Tracer family products, or a Varitrac CCP. Current unit status conditions and set points may be monitored and /or edited via this data communication feature. The network type is a twisted wire pair serial communication. Override Commands The following override commands may be received by the Unit Control Module (U.C.M.) from the Tracer System. Control Mode, Action, & Offset (1 thru 12) 1. Control Mode - The U.C.M. Control Mode may be edited from occupied to unoccupied to accommodate night setback/setup. 2. Control Action- The Control Action may be edited from cooling to heating, changing the primary air damper to a heating source. This will accommodate a cooling/heating changeover system. 3. Control Offset- Enabling Control Offset will increase the cooling temperature set point and decrease the heating temperature set point by a control offset value stored at the U.C.M. This function facilitates demand limiting in the occupied mode. 4. Drive damper fully open. 5. Drive damper fully closed. 6. Drive damper to maximum airflow set point. 7. Drive damper to minimum airflow set point. 8. Disable unit fan. CITY OF TIGARD BUILDING DIVISION PERMIT #: PLM 2006.00336•i 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/612006 Phone: (503) 639 -4171 p . I � L � Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 11/13/2006 TIME: 7 :04AM PAGE: 16 SITE ADDRESS: 0.3522 SW WASHINGTON SQUARE RCI A 7`x`.3 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: EDDIE BAUER DESCRIPTION: fixture is (1) drinking fountain. OWNER: WASHINGTON SQUARE LLC, PHONE #: 503. 638 -81365 CONTRACTOR: MODERN PLUMBING PHONE #: 503-691-6166 Inspection Request Scheduled For: Date: 11/13/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 399 Plumbing final 039641-02 818- 314 -2752 N Corrections /Comments / Instructions: 1 (i , ( \, ' ,V- / z ../ V !. -ASS n PARTIAL APPROVAL n CANCEL I 1 NO ACCESS FAIL n CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED �/� Inspector: /1R.. Date: /l 7 A 'f Phone #: (503) 718- 2 YZ- -�' P CITY OF TIGARD . BUILDING DIVISION - PERMIT #: PLM2006- 003$1 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/612006 Phone: (503) 639 -4171 21I Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 9/1512006 TIME: 7106AM PAGE: 30 SITE ADDRESS: 09522 SW WASHINGTON SQUARE RD H - 7 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: EDDIE BAUER DESCRIPTION: TI - ,ether fixture is (1) drinking fountain. OWNER: WASHINGTON SQUARE. LLC, PHONE #: 503- 639.8865 CONTRACTOR: MODERN PLUMBING PHONE #: 5O3-M1 -€;166 • Inspection Request Scheduled For: Date: 3/15/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 320 Plumbing rough -in 036602 -01 503.691- 6166 '¥ Corrections /Comments /Instructions: 17 1 ` , '` C I WA SS PARTIAL APPROVAL CANCEL l NO ACCESS I I FAIL CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED I, 37.-0' dr g 4 0 Inspector: i v Date: P hone #: (503) 718- • CITY OF TIGARD . ___ BUILDING DIVISION . . , _.. PERMIT #: PLM200S-00361 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 91612006 Phone: (503) 639-4171 _Vilit Inspection Requests (24 Hrs.): (503) 639-4175 INSPECTION WORKSHEET FOR DATE: 9/13/2006 TIME: 7:02AM PAGE: 33 SITE ADDRESS: 095 SW WASHINGTON SQUARE RD H CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: .EDDIE BAUER DESCRIPTION: TI - other fixture is (1) drinking fountain. OWNER: WASHINGTON SQUARE LLC, PHONE #: 503-639-8865 CONTRACTOR: MODERN PLUMBING PHONE #: 603-691-6166 Inspection Request Scheduled For: Date: VI:3/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 305 Plumbing underslab 036446-01 8113-314-2792 Y Corrections/Comments/ Instructions: Piv■ — PASS 1 1 PARTIAL APPROVAL n CANCEL NO ACCESS 1 FAIL 1 1 CALL FOR INSPECTION 1 1 ADDITIONAL FEES ASSESSED 1• Inspector: 1,LE Date: ,, Phone #: (503) 718-