Loading...
Permit 1 - ( ITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2008 -00222 j' ` ° ' COMMUNITY DEVELOPMENT DATE ISSUED: 7/21/2008 TrG 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2S 10X8 - 00100 SITE ADDRESS: 12850 SW GRANT AVE ZONING: R - SUBDIVISION: CF TIGARD ELEMENTARY LOT: 041 JURISDICTION: TIG PROJECT: BROADWAY ROSE THEATRE CO Project Description: Fire alarm. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5 -1HR sf N: S: E: W: OCCUPANCY GRP: Al TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 641 BASEMENT: sf AREA SEP. RATED: STOR: 2 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 13,975.00 Owner: Contractor: TIGARD TUALATIN SCHOOL DIST. #23 MASTER ALARM LLC 6960 SW SANDBURG ST 1110 NW FLANDERS TIGARD, OR 97223 PORTLAND, OR 97209 Phone: Contact #: PRI 503 - 222 -5083 FAX 503 - 227 -4992 Reg #: LIC 125364 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 6/27/2008 $148.30 [TAX] I2% State Surch 6/27/2008 $17.80 [FLS] FLS Pin Rv 6/27/2008 $59.32 Total $225.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 thr ugh OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.234 Issued B • , / �j i ;/ Permittee Signature: € Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building-} ernnit Applicatioi;i Fire Protection System ; '�' ' Q� ° N FOR ` y RECEIVE r OFH ICE USE ONLY _`-.r to I t_ f , i :, :rs c City Of Tigard Date / : ��� Permn No. P • a 13125 SW Hall Blvd., Tigard, OR 97223 Plan Rev' f I Phone: 503.639.4171 Fax: 503.598.1960 JUN 2 7 2008 Date;. : �At9/�T7i� Other Permit: /� °uT Inspection Line: 503.639.4175 Date Read /By: A ,. See Page 2 for Wit'^?• Internet: and -or. oV Internet: www.ti Notifies I t,.d j'1S Q` 1 i Supplemental Information g g CITY OFTIGARD w BURLING DIVISaO . r, , : ' / - TYPE OF WO / RE (I, I ' D ATA : 1- AN 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all RI Addition /alteration /replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling IN Commercial /industrial Valuation: $���G�' ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: / 2-,8,5b . (A- G'C.,1 t f New dwelling area: square feet City/State /ZIP: T c ,- l , 97 22 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: 1 2u ( ,v ; , i Rc2 ` ? b- Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. _ Valuation: $ -Z' ot� - Srr"-LP'' l tit de,/ d-e pi av2 v C� ef / ✓ Existing building area: C' / squarefeet New building area: square feet 0 PROPERTY OWNER ❑ TENANT - Number of stories: Name: Type of construction: Address: Occupancy groups: City/State /ZIP: Existing: Phone: ( ) Fax: ( ) New: 0 APPLICANT ❑ CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City/State/ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) I Fax::( ) E -mail: CONTRACTOR • BUILDING PERMIT FEES* Business name: // ; � .5re /�� .4e ! '"�C.� (Please refer to fee schedule) l ( • ,s ��Pr z9�wc�t Nr C Permit fee: yG Address: / / (0 i r=(0p in/r,Qo — ° D • 3l� State surcharge (12 /° of permit fee): / 7, 2,-.0 p City/State /ZIP: /2 { 0 4 c..0., n d' l 249v FLS plan review (40% of permit fee): 1 Phone: (S'-- ) 22 , 408 Fax: ( ) 2 2 7 _ 4 7 ,, (Due upon application.) ,3d� CCB lic.: 1z .z, .- 3 4 Total permit fees: /s '/- Amount received: 0 14 -5 Authorized signature: (42„,_ � This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: l � �z��o/2640a � 1. Sul 74,..44/1. Date: * Fee methodology set by Tri- County Building Industry Service Board. f / 6e- , \BuildingTermits \ FPS-PermitApp.doc 03/23/06 440- 4613T(1 I /02/COM/WEB) —� 373'Y‘.1— City of Tigard, Oregon m 13125 SW Hall Blvd. O Tigard, OR 97223 iF x , ; ";r q Vi '' kK h Y Tj :''' ' f r July 18, 2008 �h f r it . T ' RE: FIRE ALARM SYSTEM ra t Proiect Information Building Permit: BUP2008 -00222 Construction Type: 5A Tenant Name: Broadway Rose Occupancy Type: Al Address: 12850 SW Grant St. Required: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), 2007 edition the Oregon Fire Code 2007 edition and 2002 edition of NFPA 72. The submitted plans are approved subject to the following. General Requirements A separate low- voltage electrical permit is required for installation and inspection of alarm wiring. A completed inspection and testing form is required at the time of final inspection containing the information as outlined in NFPA section 10.6.2.3. TESTING — NFPA 72 Chapter 10, OFC 901.2.1, 901.5, 903.5 1. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the building inspector. All functions of the system or alteration shall be tested. 2. A record of completion in accordance with NFPD 72 verifying that the system has been installed in accordance with the approved plans and specifications shall be provided. VISUAL ALARMS — NFPA 72 - 5.14.5, 7.5.4, OSSC chapter 9 & 11 3. When required; Visual alarms shall be located not less than 80 inches and not more than 96 inches above floor level. When a low ceiling exists, the visual alarm shall be mounted within the dimensions stated above and at least 6 inches below the ceiling. No place in a room shall be more than 50 feet from a visual signal. In corridors spacing between devices shall be no more than 100 Ft. and no more than 15 Ft. from the end. MANUAL ALARM - 1109.2.3.5, 1109.2.3.6 OSSC 4. Manual Fire Alarm activation devices when installed shall be mounted in the following reach ranges: • Forward Reach - 15 inches to 48 inches above the floor. • Side Reach — 9 inches to 54 inches above the floor. Phone: 503.639.4171 • Fax: 503.684.7297 o www.tigard- or.gov o TTY Relay: 503.684.2772 ALARM SIGNALS — OFC 903.4 5. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA 72 or, when approved by the fire code official, shall sound an audible signal at a constantly attended location. 6. Duct smoke detectors shall be connected to the building's fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open -area detection. 7. Automatic fire - extinguishing systems shall be connected to the building fire alarm system where a fire alarm system is required by another section of this code or is otherwise installed. OSSC 907.13 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull , Dan Nels•n, Senior Plans Examiner (503) 718 -2436 dann @tigard- or.gov • C& l � qt. 45') oe nnv \ s O 41 11 PHILLIPS W ftmsga ELECTRONICS EST. 1952 (503) 222-5083 1110 N.W. FLANDERS STREET PORTLAND, OREGON 97209 FAX (503) 227 -4992 The Broadway Rose Theatre 1285 S.W. Grant Tigard, Or. 97233 Scope Of Work Sprinkler Monitoring System, which includes one Fire Alarm control panel, with dual telephone line Dialer for 24 hour monitoring.System also includes One smoke detector above the control panel,manual Pull station adjacent to the sprinkler riser.Connection To one flow and two tamper switchs.Eighteen Horn Strobe units throughout, and four strobe only units in The rest rooms.Installation of six manual pull stations Near the exit doors. CT OF TIGARD Approver Conditionally Approved.. t See Letter to: Follow.-..,.. ( j � ' . .- OFFICE COPY I ! . . ..- .. , _____________■---_____ :.,.. -----"-- ' \ 0 1 ___________I- - - • .,, ----''' -.-c - 7 '.` . SI 0 • -..., , 0 lair • __ - CE - r. ICE 7 ' OFFICE 1 -- OFFICE j ak , OFF ICE SW ' = 7.. \ ........r■- --- - ---. 1= ,.n'' 41 "I ° ' W 1 ‘, ' r-,f.1 • A — -----.----------------• ■ ,-- - 7,.p ,,‘ T , . gik: .,, , ..., ----7 '. • ..?...fq V ---- , / \ i ' . ; • .__., - , ... ;U '---S asj ii-i .- -Sp/Ai/del/ ko[ge L.,,;-i-h \ ,, GREEN Ark '' r -3 \ ' ""I" • c ItiM, . . age -Flow .4 . lip / ,.. '''. lair . a . ,.._,_,. p c. z OFF IC% • i N I - -- -525ir--- .., ilic6.--- - • gm ,eill : PI• --,)-1EN ;' ' 41111 ' ' AI. in IN, • .w 'W. %iv ,— . .....1,,„ . ■ _------,, Mignolliw abi ••• /7 f'••111 i---- p ---1- : . ,t ,, / : . •, G is vei.- ON M C:=3...• ME. c --- ii . ,_, Ili If ir ,,... NE C ... • • , ._ '! ,r, •--■-7.-- ; /I H TOR S . 0 ....—:. _ , ' .._____,_. 1 1. SPA. A ,,. 7_. 0 .,.___r.- r _,r= = , . ! , , ,.......,,, 7 ,--,_RRI --. e , , ! 1,,JI • , a a.„., 1 . 1 3..0. i ink s , 7 MI= . 0 Y L '-)" ' Li ' - . lug. ' - _ 7, 1;&? ' 0 0 01 0 . ' , ■.:.) / TS r1 LW II , • . • IE! • . • 1 C*'71 67, , Q2/ ailli . I% A :, . 1 i-1- Di. om .,.,., i ,..i.... , , _____,, _, ,, .- 71F0 1 !I „. L . : we we . ,,._.:,-__..__i.___,_;. :. iumtsi ..... i 1 , ii ' NW , , :-. ,, 6 4 sI-4op. gh •-•, . • , , •il= ,..<-.) -s. CI ', '• w ,.__ , ,,__, 71 ,,_ j , 1 C=. I ; I 1 .■ ' ; < .k.r 4 1 :0 ' " . • Ai 0 5TAr...E 0 ucus:- . - .- r-1 • ' ' ' 6 v , . r cl:P . --,..,.... - -• AI ' M = ,_. 7 ,-- 7 !--J :7 ' • '''::- I ''' 1.- L.* z 1 , CONF OFFICE ' i - / <7) :. • t , 1G, , . . . . s , ak , ak . ti • ' 411\ ' • ' . . , -- r7 ' r''' ,--. •--- •.- :S.- - ,--. , ..- , ..,-;. , - : ' . Mg, : , ilp !.i. ■ H ' --J, r H ,,,,--, H ---4, _ ic ,„: ! . =] !I as 7 • : ' >---. ' ' %-1 . I '!-. '..--- H ICCNICESSION " CM ,- 7 ' .Fin !ffil, \\ 1 ;17'' ' fi 7 \ Q ,_- .! ,--- '-'. : ' .-- !....., - ' c L : ' .--------- —1 DI ; ,,,, , .: ,_., r -, .„.. n-, .__, 7- s • . ,.\\ (ii) ; „ IOCET\ ; ow ; . , , i Irlik • : ' I ,/ : WM ,, AI ..-■ , ...--, . • , -. . i D " . 4; 10 ow IE 1-1DrN .S4 vi-..e 51 ..-., ..___; ,... 7 , , HI , , r _, HI I ! , . ■ Pk) ta /,.., I; El Li 0 1__:, 'El ..__, (-- L_ cj 1 ! ' r HI - . • 0 . 1 \ .‘ P C31, !!ct ‘'ll II II il II ll 11(1141 i i ' El Stre.)...e_ ioNI , Loe313 eLmi ! i _ , .-. A .1 . I • 1 ; i ON. =1 ■ I '. : e...s , 4 . P PI am iActi PuAt _C-64-1 ; ;= g • 1 4 I , t • z ! ....I 0 . . ... El Ah Al UV e c' do r PCt.N 1 1 ---- o r*. ma : 1" .* 11•1 • ' ' ' ffl El ,..__ ,. 0 • Ar)Dge, be+ eC:PQ/' FiLLA .' \ , 1 ■ . , . t■- • irk mm . • ) , : ."-• i ID , • . • -- ' . . 41111 , ' Al Tke &"od LI Le; ci.. P,o_s g, ttte..ari-re- . : IZir CIF ; : c 12S5 g M. 6,ranri• : " . 7 ---5 TCayA , Or, 43 1 2.2.3 '''- n FIRST R_OOR PLAN .- .., (i.is _cease) — .• se . . <DI KI> IN 4 --- 4 , ,s --1 . 1 ' riff CD +11 ' 1 ' hi NV i,___:___,Cilk\b■ — _. 0 – -- -- -- - - - _-- . . a_-_11-11EICTI: ITELET.11117_1=-7. ua 41( >" '- LfIll Iii 1 ICE T_IT_TiLTEIS 7-- • 1 • TUT::11 IITTI .T J_LLILITIEETII 1 a - t --1- 11. T 1 I.11.1_1_11TIT_Tt_T_TU b c27 titil_litir 1.LI TiTr.E1ClifT_Ilfi 1 ,.; 1..1.1_1 I_ .1_1 1 L 1 1 II 1 r" --- 1: IN 'A Ill> (ifi> LIT - 1 - .I 1 LI. I L'CLT11711 ----- , , Tr — „="C — Flit TirriatELL1.71T. Eli : =--:-: t t:11 T_J =----- :=11711T 1TX FT - 11 T 1 1:1.13.111:1 -:-:-.= 1 L - [ 1 L11,1 FT T1 - - -- -7 ,..1 - - 1.....•1 —_, qi CI .-7./ i , a1 - -- p• • ce • t 4 -.- , 4_ 4 Q 0 7= " ----• 1 [g El 0 E1 ® ,.; x y- h 'Js o�P "h x + " 'r �x"K P jt, -i *w. ,6 w .:.� +r r >Y , S+"kM: 0 "5 ,, i 3� T� a' ij � .... ,, #� �d��'�rek, °� ��, ,`?i �"��3 aka•... , t+wb+'�- �'�.+si.� is e al ��{. 'St` as � f�:t - . d'vrM �'n � a"� „ � a: x^ k;3y >.r2C.� Y zx, .,,.4 :13^, y a �?,« s �� ,," FIR ELARIv1 y �s t(.,r,� ,, ' ',Y • '', � *', -'<'y ,. �. ' 4' , , . � X43 .:n # ... zs x 4 a ,; Y b��± J '1 , . ; `. ', ii;; t ri g s x �w r ' a ? r , � a Model 52 08 s ` F ire Alarm Control Panel with 'f Digital Communicator r 1,,,,,.., , �� � , The Fire Alarm Control Designed to Grow with Y our Systems Needs, Without The Growing . L,....4. ,, ;.,-...,;NA, T1 , ' , "- Pains. r te " x The SK -5208 is a microprocessor based control panel with built -in UL listed communicator designed for applications requiring smoke detection, , i 79, manual pull stations, and sprinkler supervision. It features an easy to read ' ' . . 'G <\ . � ,,: LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features • Built -in synchronization fo appliances fr om AMSECO ®, � ;a • 10 zones, 8 Class B (Style B) and 2 PP -,-," .., Class A (Style D) or Class B (Style Gentex®, Faraday, System Sensor®, B) zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O Programmable date settings for 41 modules can be mounted remotely Daylight Saving Time" from the main control panel Clock source setting options for 50 �°� • Event History Buffer (150 events) Hz, 60 Hz, or internal (uses the x ��'`. • with date /time stamp panel's intemal clock) f -£ .t'. • All zones are compatible with 2- or Specifications ',� ' � �f� , 4 -wire detectors Operating Voltage: 24 VDC b� iA' • 8 selectable /programmable output , � . y � ' ' li. patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp „ �� � ` • Built -in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140mA art„ • 4 Notification Appliance Circuits Alarm: 460 mA kt , :, ,s' • 4 programmable general purpose Flush Mounting Dimensions: ` ru-, -3 ' -• ,-, #,,,,, .; , , relays Height: 24.75” (62.9 cm) s . • Programmable smoke verification, Width: 14.5" (36.8 cm) `_ s.. pre -alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding SK - 5208 that can help minimize false alarms Overall Dimensions: • Programmable from the built -in Height: 26-3/8" (67 cm) SKSS Downloading Software control panel touchpad, remote Width: 17 -3/16" (43.66 cm) annunciator, or Windows® SKSS Total Depth: 4" (10.16 cm) Plex 2 Door Option downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on -site (0° to 49° C) • UL Listed up /downloading with Windows® Humidity: 10 - 93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429 -92 -E Vol. XIII • Built -in walk test feature Optional Accessories • Single or dual interlock water • SK -5235 LCD Remote Annunciator • SK -5217 10 Zone Expander releasing capability • Plex door option combines a dead (2 max. per system) front cabinet door with a clear SK -5280 Status Display Module (8 window, limiting access to the pane max. per system) y "" ' " . SILENT while providing single button ▪ 7181 Fire Zone Converter d operation of the reset and silence • 5220 Direct Connect Module 4 KNIGHT functions • 5824 Serial /Parallel Printer Interface `` °'(` by Honeywell • Programmable AC trouble relay Module u Ii1N T , yr . «. sp . v„ ,t .,�... s• Kw ft ,�5 Sa •`�M hS i c sk.m ,: M C t # � � ��r! Model 5208 a "' ` " Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled /disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 -,;, Telephone Line 2 Direct Connect - • For On- Site Programming 2 Class A (Style D) or Classy B (Style B) Initiation Circuits a : Programmable 09a r Form C Relays t,•;, mg y. �, disc - 8 Class B (Style B) „ hu a Notification t Initiation Circuits Appliance Circuits an 1 l 3 5235 Remote 1• " Annunciators SBUS Devices ::i �.... 5280, 5217, & 5824 To AC (° -) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIG keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev B, 11/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. • Control Panel Installation Table 3 -2: Current Draw Calculations Device # of Devices Current per Device Standby Alarm Current Current For each device use this formula: This column X Ilus column = Current per number of devices. SK -5208 Fire Panel (Current draw Standby: 140 mA 140 mA from battery) 1 Alarm: 460 mA 460 mA Panel Accessories SK -5217 Zone Expander (2 max.) Standby: 60 mA mA Alarm: 260 mA mA 5824 Serial/Parallel Interface m m (1 max) Standby: 45 mA -..A Gateway Module Alarm: 45 mA _..._._... A 5220 Direct Connect Standby: 15 mA �,U; Alarm: 15 mA - • mA SK -5235 Annunciator (6 max.) Standby: 30 mA 30 mA Alarm: 50 mA - D mA Relay Standby: 10 mA --mA SK -5280 Status Display Module (8 max.) (max.) Alarm: 80 mA mA Outputs Per output 100 mA ,-, . mA Max. 700 mA mA 7181 Zone Converter Standby: 35 mA - rnA Alarm: 65 mA mA A Total System Current / 7f) SAD Smoke Detectors s Se_ a / Standby: • 2Z - 0,904-- inA at mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA B Smoke Detector Current . w mA ,2,� mA Notification Appliances - 42 .rr..42/ P2E 22 Alarm: 90 mA I I /7a2, mA Alarm: mA mA Alarm: mA mA Alarm: mA mA C Notification Appliances Current / 9O mA Additional Devices Standby: mA Alarm: mA Standby: mA Alarm: mA D Additional Devices Current mA E Total current ratings of all devices in system (line A + line B + C +D) /70 mA 2.5 3 mA F Total current ratings converted to amperes (line E x .001): a 1 7 A A G Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1- 5.2.5): H 2473 H Multiply lines F and G. Total standby AH 4.0,f AH I Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) « 0843 H J Multiply lines F and I. Total alarm , AH K "Add lines H and J. Total ampere A AH hours required `t. P/N 151204 3 -7 6-r-_ . ENSO .. Premises: Circuit: Broadway Rose Theatre Class B @ 18 AWG 1285 S.W. Ceder Filtered (DC) 24 -volt Supply (1 amp circuit) Tigard, Or. 97223 Starting Voltage = 20.4 Prepared By: Notes: David Smith There are four separate appliance outputs on the SK 5208 Phillips Electronics This voltage drop calculation shows approximate 1/4 of 1110 N.W. Flanders the entire system. Portland, Or. 97209 (503) 222 -5083 Type and Model Candela ?Current Next i Total 12 14 16 18 Wall Horn /Strobe (2 Wire) P2R 15/75 ' 0.08 100 1 100 20.24 20.14 19.99 19.75 E E Wall Horn /Strobe (2 Wire) P2R 15/75 1 0.08 100 1 200 20.11 19.94 19.67 19.24 1 Wall Horn /Strobe (2 Wire) P2R 15/75 0.08 100 j 300 20.01 19.79 19.42 18.85 , Wall Horn /Strobe (2 Wire) P2R 15/75 a 0.08 100 j 400 19.95 19.69 19.26 18.59 Wall Horn /Strobe (2 Wire) P2R ' 15/75 9 0.08 100 1 500 19.92 19.63 i 19.18 18.46 __ � Total current /amps 0.4 vdc Toss 0.48 0.77 1 1.22 1.94 t. INSTALLATION Alp M4t€NTENANICE INSTRUCTIONS Series Y, Photoele c r c Smoke Detector 3825 Ohio Avenue, St. Charms, Illinois ( 1",'- l- 800- SENSOR2, FAX: 630 -3 -6495 Models: 2W -B 2WT -B INW1V.sy,teu)sefisur.COW 4W -6t, 4YVT-B Before Installing Please read thoroughly System . Sensor manual A05- .1003, Two LEDs on the detector provide a local visual indication of the Applications Guide for System Smoke Detectors, which provides detector's status: detailed information on detector spacing, placement, zoning, wir gable 1: detector LED Modes Mg, and special applications. Copies of this manual are available front System Sensor LED -- ` Red LED - c nsor at no charge. _ -- _- ____ -_ -_-___ Power -up [Mink 10 sec Blink 10 sec NOTICE: This manual shall be left with the owner /user of this -- Norma) (t 1[ 1by j Blink i sec - -- equipment. _ _ - - -- - -- - -- Out of sensitivity _-- I Blink 5 sec IMPORTANT: This detector must be tested and maintained regu.- Freeze Trouble -- - -- Blink t0 se_ larly following NFPA 72 requirements. At a minimum, cleaning Alarm -• Solid should be performed annually. .After an initial power -up delay, the red and green LEDs will blink General Description synchronously once every ten seconds. It `.dill lake approxiiwitely SO tvlocle.h, 21h' -B and 2l -I3 are 2 -wire photoelectric smoke detect seconds for the detector to finis) the power -up cycle (Se, 'Llble 2). tors; models 4W -B and 4WT -B are 4 -wire photoelectric: smoke Table 2: Power -up sequence for LED Status tndicatiora* detectors. All models incorporate a state -of -the -art optical sensing - - -- — -- - -- - - -- Condition Duration chamber and an advanced microprocessor. The microprocessor - - - -- - - ______.- .__�_- ---- -- ,--- -_�_ -_ Initial LED Status Indication 80 seconds allows the detector to automatically adjust its sensitivity back — °--- ---- ------ .-- - - - --- .— --- -- - - -- ---- - -- - -- to the when it becomes more sensitive due to initial LED Status Indication 4 minutes LUAU!'" contaminants settling in its cliaruber. In order for this feature if excessive electrical noise is present) - Refer to Electrical Specifications for scar[ -up nine tr. cunjucetio tt .it1) pi. 21 at:u to wort: properly, the chamber rnust never be opened while verification. power is applied to the smoke detector. This includes cleaning, become necessary, maintenance or screen 1eplacernt ni.. Should ti. NOTE: I[, during power -tip, the detector determines there is the screen/sensing chamber is field replaceable. Models 2'WTB excessive electrical noise in the system such as those caused cry and 4\ \r'I' -B also feature a restorable, built -in, fixed temperature irrlproper grounding of the system. ur the conduit, both LEDs will 1 :i5' ) thermal iletei lot and are also capable of sensing a freeze blink for up to 4 minutes before displaying detector status [see condition if the temperature is below 410F. Table 2). All i Series detectors are designed to provide open area protec Alter power up has cc ;nlpieteti and cite detector is urt ica)in : lion. Two wire models must be used with compatible UL Listed normally within its listed sensitivity range, the greets LED blinks panels only. once every five seconds. If the detector is in need of maintenance because its sensitivity has shifted outside the listed limits, the red \Vbeti used with an i Series compatible control panel or the i` L,EI) blirdcs once every five seconds. When the detector is in 111e Series 2W-MOD module (refer 10 installa000 manual D500.46 -00), alum mode, the reel 11 D latches tin. - Me Lf:]_7 inchc ;t1O0 int1S1. [101 the 2W-b and 2W -B are capable of generating a "maintenance be used in lieu of the tests specified under Testing. 10 a freeze needed" signal. The 2W -MOD can indicate a need for cleaning, trouble condition, the red LED will blink once every 10 seconds replacement, 01 a freeze condition (DA/TB only) al. the c :onttol (refer to Table 1). panel or module. • To measure the detector's sensitivity, the i' Series Model SENS- Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is RDR Infrared Sensitivity Reader tool (see Figure 4) should he simplified by the use of a mounting base that may be pre -wired used. to the system 3llowir[g the detector to be easily installed or removed. The mounting base installation is further simplified by Models 2W b and 2WJ 13 aide, include an output that allows an the incorporation of features compatible with drywall fasteners. optional Model RA400Z Remote Annunciator to be connected. • Mounting Each i` Series detector is supplied with a mounting base that can be mounted: 1. To a single gang box, or 2. To a 31/2-inch or 4 -inch octagonal box, or 3. To a 4 -inch square box with a plaster ring, or 4, Direct mount: 01 t0 ceiling using drywall fasteners (Figure 2)• 1)100.96 -00 . 1 1S6-1 Sti0 • / Remove ,b~de,tcqo, cover by turning counterclockwise. (See Figure 6: Chamber Figure 6.) 2. Vacuum the cover or .use canned air to remove any dust or 1771 debris. DETECTOR 6.1 COVEfi. 3. Remove the ,op half of the screen/sensing chamber by lifting straight ny (Figure W. 4. Vacuum or use canned air w remove any dust m particles that CHAMBER o,rp�x�uuubo'bcbumhobahr,. (TO? HALF) 5. Replace the m; half u[the screen/sensing chamber by align- ing the anuw on d`, s:re*u/,cnxiug chamber with U`~ arrow on the housing_ Press down firmly until the screen/sensing chniher is fully seated. 6. Replace the detector cover by p]acing it over the scJeen/sensing ___uoECron chamber and turning it clockwise until 11 snaps mb place. ,0 7. Reinstall me detector and test. (See the Testing section.) S. Notify the proper auUmubeswbco thcsys/rm is back in service. Electrical Specifications 2 4 • Physical Specifications System Voltage - Nominal: 12/24 12/24 Volts Non-polarized Heat Sensor Min.: 8.5 8.5 Volts (Model zvvTo and 4vI-a): e57 (57.2~c) Max.: 35 Volts , Freeze Trouble Wax. Ripple YnUage: 30 30 % peak to peak (Modellu/T-B and 4WT-B): *1.^[ (5^[) of applied voltage Operating Temperature Range: • Max. Standby Current.: 50 2W-13 and 4\f43: 32 to )z0°F (3m49°C) Peak Standby Current: 100 — /IA -- 2WT-Dood4\vT-B: 32 to 00~P (0/a37.8`C) Max. Alarm Current: 130 20 rnA 12 Volt Systems Operating Humidity Range: 0 /n95% RH non-condensing (For 2W-B ^ Storage Tenmperature Range: —« to 158^T (-20 to 70^C) panel must limit current) BO Diameter (including base): 5.3 inches Alarm Contact Ratings: -- 0.5 amp ao YAC/DC Height (including b^^r : 2.0 inches Alarm Reset Time: 0.3 0.3 sec Weight: 6.3 oz. Max. Start-up Capacitance: 0.1 -- uy Latching Ala Ern: Reset by momu'uq/ power jilt eou\ukx Maximum initial • Start-up Time: 45 l; sec Alarm Verification' Sux -vpTime: 15 15 sec 'Assumes 1110 0101111 in:rift reset ,ne.a/oseLotuis= less. smtld the alarm verification 1 exceed m seconds. =,ntellici.X1/1=^mw..na°-a;:*= ���� refer to insert for �����^��� of Fire ����� Systems ^ ~� ~�^~ ~ ^~^ the ~~ ~~~~~ ~^ ~ ^ ~- -�--- TMee-Year mmited Warranty Syu°usaye, xyn^mS m":thxu SML)ke oazxzu be tree from detects /r. Repair oepsthuwth ux � _ ~ 3uzs Onto Avenue, St. coarh :OU 1r4. and °"*~,,^i./, tinder ,.=^^/ use ~^°°,"^lo," ..~i.u^^"^/. a"^"e.i.u.'`""`"x"nc.°" and ~."p''^/ cause ^/ '^'`"". years x"" date a manufacture. System Sensor makes u" other express war- The Company shall not b~ obligated to repair ", replace ""u, ale m""/ ram) for this smoke detector. No ^:*m. representative. dealer. ^, employee of xe defective :,mvs of damage, unreasonable. use, modifications, ", alterations the Company has a" authority °increase or alter the obligations ", limitations occurring after the date of manufacture. m= CaSe shall the Company be i/ableu" "/,uyxan^"». The Company's obligation ofw"Warranty ohall be 11(11111113 10 any consequential s;acu"wm u"rn°ew" for breach "' this ° ally other vu=v. ` '"°pl"^°°"`of .rtnv part of o° smoke detector which is 00113 u expressed or implied whatsoever, "°" x the loss ",damage u '°", the oefee,/°/" materials ",w"a.,ansh4 under mwo^/ And service during Company's negligence or fault. Some states uo Jim a the exclusion ",m"& the three year period commencing wilts, xe date of manufacture. After plum- non of incidental m consequential damages, su the above limitation ",exclusion ,.0 System Sensors mu free number !WO-SENSOR! (no-7672 ) for ^ Return may not apply m you. This Warranty gives you specific /":ai rights, and '". a^' Authorization number, send detective units postage prepaid to: System Sensor, also have other rI$I1IS O'lIIc(l ','Ory 1(0(15 03010 10 0010. • FCC Statement "This device complies with part a../ the FCC Rules. Operation a subject m the foluw/xxm" This device may nut cause harmful o./,,^,,um. and u`this ' device !mist accept any interference received, including interference that tu* cause undesired operation. Note 'This °c,,=p"°.^=,»"^'. tested and found m ""."plv with the x.=a fur ^ Class o digital device. ou,".umm Pan /E.^/.he FCC: Rules. These are .1"^.«",d'" provide reasonable protection against harmful i"°rf"rence/"" residential installation. This equipment u".°=tes. uses and can radiate radio ^"v"""cy and, If • not installed and used o. accordance with the instructions, may c^u,,/.axm/m interference m radio communications. u"°".a. there i,"" o,^""u" :"".°"`"^ will not occur /,^ particular installation. /: this equipment does cause harmful interference m ratite m television reception, which can be.e/",0 tinning the equipment *t anti on, the user 10 encouraged /^ !Sy m eo°°, the /"terfere^°/v one ","""" the ^wOWi"o measures: keor"xm relocate the receiving mteua Increase the separation between the ewipaeu,and/ece*a cmm,ct the equipment into u. outlet m.o" different from that m which the receiver ucun.ec,.ct. Consult the um/Kv,mepui.ncm radio/TV technician for help. n/ou.v:uo 156-1800a8x ^zoosxyswmSensor . Flre•LITe• ALarrns BG -8 Series z incorPoraTeD Manual Fire Alarm Pull Stations April 11, 1995 + GENERAL The BG -8 Manual Fire Alarm Pull Station provides a single - action, normally -open contact alarm initiating point for use with ,- A L� f L �- California UL listed Fire Alarm Control Panels. State Fire 38 -93 -E ® . u' Marshal FEATURES • Complies with Americans with Disabilities Act. A D q S711 iii 7150- 0075:148 • Sturdy metal construction. 6� �A • Simple operation. • Operation does not require replacement of parts. x i TV,,'y ,�n�i ' (7.74' , 71 t °2T 14a /'r �f''1'"LA rtFar43 • Drawing of flames on cover helps communicate purpose of this . h ¢ r 7 „ . device to people who do not read English words. i • Designed to prevent false alarms when bumped, shaken, or , . ,: , jarred. ' t • Listed to UL 38. ; ' P � � 1 Designed for indoor use in atmospheres which are not poten - �� 1 G F 7 r y Y kk y . . il , tially explosive. Use as a means of allowing anyone on the premises to turn in a non -coded alarm quickly, without chance ' of error. Typical uses include:u 1. Schools. x yt 2. Hospitals. 3. Retail stores. ' w rte, ‘ :t.. 4. Industrial plants. '' " 5. Warehouses. ; I ,� r F t Compatible with any appropriate control panel to: Y r " 3 , ,, i s 'yN 4,4* y C 4,...,',..".'',' o t < < t '.. l 1 , ' , r 1 r �} . s � � 1 , ,,4'/2`,:' ah ',,:,,o.'.1!. y 1. Initiate local alarm signals. 2. Trip a municipal fire alarm box. � 1,4 I 3. Start fire pumps. , d, !'!::. f 4. Any other function that can be initiated or controlled by the w+ closing of a switch contact. k ' ;, . $4 9 r � t f � � OPERATION The stations feature non-break-glass operation. ; k'; , � `.` ., i s ', 1 They are operated by a pull on the pull cover. This causes a key , , u r I. latch to act against a retaining mechanism until adequate force L r a ` is applied to open the station. As the station opens, a switch is �'; released to initiate an alarm. The retainer in Model BG - is a ik ; ©r , r� F.re t permanent high tensile spring, which eliminates the need for a , t .r � f f glass retainer. When so operated, the cover hangs down (and * .� cannot be reset without use of a reset key) indicating that the station was used to initiate an alarm. (OPERATED STATIONS BG - CAN BE SEEN UP TO 100 FEET AWAY.) (Shown full size) The attractive design of the stations highlights its engineered VI simplicity and unusual dependability; bumping, shaking, or jar- 5 ,.I ring will not activate the switch or circuit. Instructions for opera - tion of the station are clearly marked on the front of the pull cover. We try to keep our product information up to date and accurate. We cannot cover all specific ISO - 9001 .;::::::::1::::;= ' applications or anticipate all requirements. All specifications are subject to change without notice. For : Engineering and Manufacturing more information conta FIre•Lite. Phone: (203) 484 - 7161 FAX: (203) 484 -7118 Quality System Certified to ® Flreure warms 12 Clintonville Road, Northford, Connecticut 06472 International Standard ISO -9001 Made in the U.S.A. rrcorr•orateo Page 1 of 2 INSTALLATION AND MAINTENANCE INSTRUCTIONS S TE SPECT ` 1� � �,`� SENSOR' ®r U o Y!l�lN.% U /' %'(r.�/i /"'r,; / � /J,� i'�i•.:•: f%8 3825 Ohio Av'entt, Si. Chilli's, tlll�loi5 60174 • �. . % l� /�!�.:55Gi.� %�G %�/✓'»%�if��'�i 800/736 -7672, EAA: 610!3.':' 1;49= Selectable Output Strobes, Horns, and Horn /Strobes Yor us,• WI; ;1 the iullo.Jiug models: 21 , P2Kk1. P2RK, P2RHK, P2W, P2WH, P4R, 1'1RH P4RK, P4la hK, i'4V,'. I'4WH, SR, SM. 512K, SRHK, SW, SWH, I'C.'It. PC2R1-i, Pt:211K, 1'i:2R1 ;R, PC::'. , 1'C2W1-I, l'C4R, f'G1Ioi, f'<:.RK. PCi1KHK, PC4V', PC4WH, SCR, SC(flt, scio , SCKHK, SCV,', SCWH, HR, 1-1RIC, HV. SR -1', SW-P, Sl H -1', P21: r', P3i' :' 1-'21:1-LP h'S +.'Ii -I, SCR r', SC;k -P, SCR.1-1 -Y, SCWI-1-P, PC2R•l', PC2W -P, Pf ?KH-P, PC2W'H-P, P4R P, P4Rii -P, F -IW -P, P46Vli -1', SR -SP, SRI-1-SP, P2K-SP. P210-1 SP, SCV, SCWH -SI', PC2W -SP, PC2:)H-SP Specifications • General Specifications Standard Operating Temperature: 32 °F to 120 "F (0°C to 49 "C) K Series Operating 'Temperature: -40°F to 151`F (FM approved to - 31'F'); See note for Table 2. Humidity Range: 10 to 93% non-condensing (indoor products) Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12DC /FWR or regulated 24DC/FWR Operating Voltage Range: 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Operating Voltage with MDL: 9 to 17.5 V (12b' nominal) or 17 to 33 V (24 V nominal) 1 P, S, PC, & SC products will opemie at 12 l% nominal only for 15 , 15/75 id. Mechanical Specifications input terminal wire gauge: 12 to 18 AWC Ceiling mount dimensions (including lens): 6.8' diameter 2.5" high (173 runs diameter x 64 nun high) 'Nall riloullr. dimensions (including lens): 5.61. x 4.7 "W x 2.5 "I) (142 rum 1.x 119 nuts W x 64 nun D) Horn dimensions: 5.61 x 4,7"W x 1.3 (142 nun 1. x 119 mm W x 33 mni D) The pwoducts in this manual may be covered by one or more 01 the following patents: 5,914,665; 5,830,178; 5,598,139; 6.049,446; 6,522,261; 6.661,337; 6,822,400; 6,833,783; 6,856.241. General Description Calculations are based on using the device current found The SpectrAlert Advance series of notification appliances in the subsequent charts and must be compatible with the offers a comprehensive range of red and white wall, ceiling, current specified for the panel or power supply used. and outdoor products including horns, strobes, and horn / wire Sizes strobes. These products are electrically backward compat- ible with the previous generation of notification appliances. 1 The designer must be :;ore that the Iasi device on the circuit While there are products specifically designed for use on voltage to operate. the device within its rated the ceiling or the wall, the products are listed to be used voltage. When calculating the voltage available to the last in either apph•t:ation, i.e., wall products could be used on device, it is necessary to consider the voltage drop due to the ceiling. SpectrAlert products are designed to be used the resistance of the wire. The thicker the h=ire, the smaller in either 12 or 24 volt L } {, or full wave rectified (FWR) sys the voltage drop. Gen rally, for purposes of detennininf; the terns. 11 required, the MD1, module may be used in order to wire size necessary for the system, it is best to consider all provide synchronization. of the devices as "lumped'' on the end of the supply circuit to simulate worst case. For the most accurate voltage drop NOTICE: This manual shall be left rwrith the owner /user of calculations use the System Sensor voltage drop calculator this equipment. available on the web or CD -ROM. Fire Alarm System Considerations Approximate wire resistance: The National Fire Alarm Code, NFPA 72, requires that all 18 AWG solid: 8 ohms /1000 it. horns, used for building evacuation installed after July 1, 16 AWG solid: 5 ohms /1000 ft. 1996, produce temporal coded signals. Signals other than 14 AWC solid: 3 ohms /1000 ft. chose used for evacuation purposes do not have to produce 12 AWC solid: 2 ohms /1000 ft. the temporal coded signal. NOTE: If Class A wiring is installed, the wire length may be Power Supply Considerations up to twice as long as on non - fault tolerant circuits. Panels typically supply DC filtered voltage or FWR (full NOTE: For 24 volt applications, the total number of strobes wave rectified) voltage. The system design engineer must on a single NAC must not exceed 40, with a maximum loop calculate the number of units used on a loop based 00 the resistance of 120 ohms. For 12 volt applications, the total type of panel supply. Be certain the sum of all the device number of strobes must not exceed 12, with a maximum currents does not exceed the current capability of the panel. loop resistance of 30 ohms. D690 -03 -00 1 156- 2769 -003R Table 7. 3 -wire Horn /Strobe Standard Candela Range (15 -115 cd) Current Draw (rnA) E 8-17.5 Volts 16-33 Volts • oc Input - --- l 15 15/75 15 15 75 __ - Temporal - High - :137 2 — 157 - -- - 182 201 _ 210 _ Temporal Low 132 _ 143 66 • r _ 93 _ 154 1.79 198 - 207 Non - temporal High -_— 141 152 91 100 116 176 201 221 229 Non- temporal Medium 133 _45 75 85 102 163 __ - 187 207 216 Non-temporal Low ` 131 144 68 79 96 1 56 182 -__ 201 210 F'WR Input - _— ---- - -- - -- --- - - - --- - --- --- - -- --- Ternporal Hi l -1 _ 136 155 80 97 112 168 190 21u 218 -- - ------ ---- - - - - -- --------- - - - --- ----- -- - - -- -- - - - - -- Ten.oral Medium r 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 _ 76 86 101 160 184 194 201 Non-temporal High 142 161 _ 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 _ 95 110 166 189 208 216 Non - tem poral Low 132 154 80 90 105 161 184 202 211 Table 8. 2 - wire Horn /Strobe High Candela Range (135 -185 cd) Current Draw (niA) 16-33 Volts ` I ` 16-33 Volts DC Input 135 150 177 185 I • FWR Input 135 150 177 i 185 Temporal t -ligh 245 259 ] 290 297 Temporal High 215 ; 231 258 i 265 Temporal Medium 235 253 `` 288 . 2.97 !Terriporal Medium 209 224 250 58 Temporal Low f'_ P �32 2'�1 202 292 Temporal Low 2r,7 221 2 %t5 } 256 - Non - temporal High 255 270 303 309 Non temporal High 233 248 275 281 Non- temporal Medium 242 25r9 293 299 INon- temporal Medium 219 232 262 ` -267 Non - temporal Low 238 254 i 291 295 Non - temporal Low 214 ) 229 256 i 262 Table 9. Horn & Horn /Strobe Output (dl3A) Figure 3. Any combination of models powered by a ---------------------------- _ - _ - -_ ._� 4l circuit Switch Sound 8 -17.5_ Volts 16-33 Volts_ Position Pattern dB _ DC FWR DC - FWR { +} 1 - -- Temporal _ H h_ _78 - - - 78 - 84 84 ■∎ {• }.) /----- • - - - - -- - { +)/'- 2 Temporal -� Medium_ 74 74 80 80 H / H II 3 Temporal Law 71 73 76 76 O ; 0 E a 4 Non tempo High 82 82 88 88 N 1 -N R \ v i 1 5 Non - temporal Medium 78 78 85 85 {_) J_ \ I ■ 6 Non-temporal Low 75 75 81 81 -- ___._ -__ _ { ) r _ -__ / (-).- - - - --- -- - - -_ -1 7* Coded High 82 82 88 88 :0 •0 8° Coded Medium 78 78 85 85 'tit 9" Coded Low 75 75 81 1 81 _ _ :B 'Horn & 4 -wire Horn/ Strobe only { ) Wiring r \ / - ; T f \ / Figure 1. Non-Synchronized devices; any combination a L R [ 1 o of models powered by a 2 circuit e , B -/ - ( +) Horn Hom /strobe Strobe Only _ V/ \ +) ( 1 / / ALr;; orr \ E Two Wire System O Any Mlx of Models \ 0 Wired tor Tandem Operation (-9 ( -) ( --) ( -) Terminal Definitions Figure 2. Synchronized devices; any combination of Figure 4. Figayre 5. models powered by a 2-wire circuit Power Supply 0) Saohe Supply ( + _ � i _ ) Supply pply i ( +) M( ran Ho (! strobe Strobe Only 0 ,r��, 0 © J ` E Two Wire System �j/ o HCIII p / Any Mlx of Models F lowor u Wired for Tandem SuPPIY ('1 - PPIY ; - 1 ;Supply ( +) \ Operation A035G00 _JL.. Synchronization Module „„ -� P2 , PC S r S kit H Series P4 & PC4 Series NOTE: For further information on synchronization see MUL, panel, or power supply installation manual. . D690 -03 -00 3 156- 2769-003R CIITY OF TI1C21 AIR D AuS:rec =6c4 2Z 7.., BUOLDONG 1111VISIION PERMIT t 13125 SW Hall Blvd., Tigard, OR 97223 A:.,,-- DATE ISSUED: fl ifii;;I:)U Phone: (503) 639-4171 ktrglille Inspection Requests (24 Hrs.): (503) 639-4175 AVAii.ita ...,......,...6..,,,,e. INSPECTION WORKSHEET FOR DATE: 1 )13/201M TIME: - i 0NA PAGE: 23 SITE ADDRESS: i Lwq (.:4 AvE CLASS OF WORK: SUBDIVISION: (.71 C_I rAin" LOT #: 011 TYPE OF USE: PROJECT NAME: I : - it=::AI'RE CD DESCRIPTION: F pr Symou Alt lring 176 Triok lei ito;,IdT7:. OWNER: i ioARD OJAI A :'Y::1 10(1A .Ftsz -#:n, PHONE #: CONTRACTOR: 1p'101'; C:C.) PHONE #: 6(K3 G2G ( 1‘10 Inspection Request Scheduled For: Date: i 2Roorn Pour Time: Code # Inspection Description Confirm # Contact # Message ... ) irt!•1 iii 1, ; , ' - - _...... — . .,-" ' , ='0:-: - '' y *N. ',.. /, i • rrections / Co m me n c 'i - f i r - .. • ,----: - ' -N, F___ e) = -C.:--_--- . • — '''',....,'■Pli_.!..,-..,--`:: - li ie - z- ■,-"( t f----- -A — e= 4- 1- ictrfp(4- 4 ) '1 Z_ R C:Po 0-- i g._(- ---, _ t (9 / fl PASS / ' . APPROVAL CANCEL I I NO ACCESS / fl FAIL Igi CALL FOR INSPECTION fl ADDITIONAL FEES ASSESSED - _ .... Inspector: . Date: i Z /S/CE Phone #: (503) 718- ler RECEIVED . • DEC 05 2 0 08 FIRE ALARM SYSTEM CITY ®F TIQAR® RECORD OF COMPLETION Name of protected property: a rota 1.011.10 R 0 SSG 7A 7 4 e. BUILDING DIVISION Address: 4 g.so SL✓ /A 6 raw* 1 T/ � , (7 le Representative of protected property (name /phone): Authority having jurisdiction: C.-1 1 C> Address /telephone number: 1. Type(s) of System or Service NFPA 72, Chapter 3 — Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 3 — Emergency Voice /Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 6 — Auxillary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: NFPA 72, Chapter 5 — Remote Station Alarm: Supervisory: NFPA 72, Chapter 5 — Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: 7 Indicate how alarm is retransmitted: V NFPA 72, Chapter 5 — Central Station Prime contractor: AM 7 t MOi - 6 r:+Ai (.g ✓/' f Central station location: 404491Mbet A 1/ 6J V,' e J , Ca l i 4 ;tin: t Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -way radio Y Digital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: (NFPA Record of Completion 1 of 4) Organization name/phone Representative name /phone Installer Pkil; l y / k�a a �Y,� ti r..� t�e7 Sev " Supplier S %1-'4 f Service organization Location of record (as- built) drawings: IN,l '774 Ft'e,, 7 Location of owners manuals: O IA g 111 Location of test reports: A contract, dated , for test and inspection in accordance with NFPA standard(s) No(s). , dated , is in effect. 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by 1e,hQ t'/,eL' //'h on /v14 )S /7K, includes the devices shown below, and has been in service since �NFPA 72, Chapters V ( - 3 ® 6 ( (circle all that apply) ✓NFPA 70, National Electrical Code, Article 760 'Manufacturer's instructions Other (s ecify): Signed: Date: / 2 ®t • Organization: Ph:/ i "r ;IC C c ti 3. Record of System Operation All operational features and functions of this system were tested by t7' '-' ,'LD9` on 12/3/9f and found to be operating properly in accordance with the requirements of: PA 72, Chapters 3 (J ® 6 6) (circle all that apply) 1/NFPA 70, National Electrical Code, Article 760 s Manufacturer's instructions Other (specif ): Signed: _ Date: /1 /t /1$ Organizat on: ph; /4 4' 4�./ 4. Alarm- Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 3 -5) Quantity: /7 Style: A Class: MANUAL (a) ! Manual stations Noncoded, activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: Partial: (a) f Smoke detectors Ion 1 Photo (b) 3 ` Duct detectors Ion Photo (c) Heat detectors FT RR FT/RR RC (NFPA Record of Completion 2 of 4) • (d) Sprinkler waterflow switches: •— Transmitters Noncoded, activating _— Coded (e) Other (list): 5. Supervisory Signal- Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded stations (b) Noncoded stations, activating transmitters (c) Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) 3 valve supervisory signaling attachments Value supervisory switches, activating -- transmitters (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) Fire pump running (g) Phase reversal • Engine -driven fire pump: (h) Selector in auto position (i) • Engine or control panel trouble (j) Fire pump running Engine -driven generator: (k) Selector in auto position (1) Control panel trouble (m) Transfer switches (n) Engine running Other supervisory function(s) (specify): 6. Alarm Notification Appliances and Circuits Quantity and class (see NFPA 72, Table 3 - 7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: Style: A Class: 8 (a) 1 Bells /7" Inch (b) Speakers (c) I Q Horns (d) Chimes (e) Other: (NFPA Record of Completion 3 of 4) (f) 22 Visual signals Type: s U 1.R with audible S w/o audible (g) _l_ Local annunciator 7. Signaling Line Circuits Quantity and class (see NFPA 72, Table 3 - 6) of signaling line circuits connected to system: Quantity: _ Style: Class: 8. System Power Supplies ,-, (a) Primary (main): '),46 Nominal voltage: /20 ✓ Current rating: �� Overcurrent protection: Type: i3ctpki/ty . .24/ Current rating: 23 4AM Location: /V e Z2 - PA mt. (b) Secondary (standby): V Storage battery: Amp -hour rating: 7 S Ail 1 Calculated capacity to drive system, in hours: 1 : - / ..a 9 24 60 Engine - driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software / (a) Operating system software revision level(s): f' (b) Application software revision level(s): (c) Revision completed by: (name) (firm) 10. Comments: (signed) for central station or alarm service company or installation contractor /supplier (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: "--- ;, — 12 (Vog (si ) o t" ce ntral station . . arm service company or installation contractor /supplier (title) (date) Up pletio qi he s tem(s) satisfactory test(s) witnessed (if required by the authority having juri diction): �1 '6o cZiDK /1 IZ.. / t (s' ed)`repr�sgDtative of the authority having jurisdiction (title) (date) (NFPA Record of Completion 4 of 4) CITY OF TIGARD BUILDING DIVISION J PERMIT #: t311P2008 0(I?2 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 7/21/2008 Phone: (503) 639 -4171 u Inspection Requests (24 Hrs.): (503) 639 -4175 .,' 'I_t .. . INSPECTION WORKSHEET FOR DATE: 12J1/2009 TIME: ,/ : 00AM PAGE: 113 SITE ADDRESS: 12050 SW GRANT AVE CLASS OF WORK: SUBDIVISION: CI: TIGARD ELEMENTARY LOT #: 041 TYPE OF USE: PROJECT NAME: BROADWAY ROSE THEATRE CO DESCRIPTION: Fire, alarm. OWNER: TIGARD TUALATIN SCHOOL DIST. #23, PHONE #: CONTRACTOR: MASTER ALARM LLC PHONE #: 503 - 222450133 Inspection Request Scheduled For: Date: 12J1/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 0713618 -t)1 503222 -6083 0 Corrections /Comments /Instructions: I IJ/ 2 — Pgr / ki b1= Y /ce & vmi 70 ,4 LA ✓Ut PG4- Z . ? g-ov (b(1 (9 0 .i r r coo r c 1--7� • s j/ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS if 0 FAI, // CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED IMO- K.,:z====:, Inspector: Date: 1� ( O) Phone #: (503) %�(Jg , P � ) 718