Plans (74) SIT2018 - 00003 O-FICF COPY TTSD MODULAR CLASSROOMS TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLSCEIVED MAR 13 2018 TIGARD OREGON CITYOFTIGARD / BUILDING DIVISION GENERAL SITE NOTES GENERAL UTILITY NOTES HMart o t '.'' Edge :vv SI 1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO THE 1. LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE PLOTTED FROM RECORD COMMENCEMENT OF WORK AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. DRAWINGS AND INTERPOLATION OF PHYSICAL EVIDENCE ON THE SITE AND ARE °o • O s" CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE AND BECOMING FAMILIAR SUBJECT TO FIELD VERIFICATION BY THE CONTRACTOR. CONTRACTOR SHALL o o s WITH THE SITE CONDITIONS PRIOR TO BIDDING. VERIFY ELEVATION SIZE AND MATERIAL OF ALL UTILITIES PRIOR TO COMMENCING o CONSTRUCTION. ] - o 2. CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THAT NEW FEATURES TIE INTO o`er / o • • • o o ° Fes` Skin EXISTING SITE DEVELOPMENT, PAVEMENT JOINTS MATCH CORRECTLY, AND THAT 2. ALL LOCATIONS FOR WORK SHALL BE CHECKED AND COORDINATED WITH EXISTING Thrift Store GENERAL DESIGN ELEVATIONS FOR NEW CONSTRUCTION PROVIDE PROPER CONDITIONS IN THE FIELD BEFORE BEGINNING CONSTRUCTION UNDER THIS ° o o 'Q PAVEMENT AND DRAINAGE SLOPES FROM EXISTING TIE IN POINTS. REPORT SECTION OR ANY OTHER SECTION. I 0 SW McDonald S1 SW McDonald St SW McDonald St SW Mr,Donald St SW McDonald Si S''N McDonald <1 DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION. O 3. THE WORKING DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW p 3. ALL CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH CITY INSPECTOR(S). EVERY OFFSET, BEND OR ELBOW REQUIRED FOR INSTALLATION IN THE SPACEPROJECT SITE QL CONTRACTOR SHALL NOTIFY CITY INSPECTORS) 72 HOURS PRIOR TO START OF PROVIDED. THEY DO NOT SHOW EVERY DIMENSION, COMPONENT PIECE, OR p s n CONSTRUCTION. FITTING REQUIRED TO COMPLETE THE PROJECT. CONTRACTOR IS RESPONSIBLEO @ o > n Hall Boulevard FOR PROVIDING A COMPLETE AND WORKING SYSTEM. DO \°° ° T o m Baptist Church 4. DURING CONSTRUCTION, THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL TWALITY PROJECT SITE HAVE A MINIMUM OF ONE (1) SET OF PERMIT APPROVED PLANS AND 4. ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE _ SPECIFICATIONS ON THE JOB SITE AT ALL TIMES. OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR DO ' MIDDLE 952-001-0010 THROUGH OAR 952-001-0090. YOU MAY OBTAIN COPIES OF 5. UPON COMPLETION OF THE CONSTRUCTION PROJECT, THE CONTRACTOR SHALL THE RULES BY CALLING THE CENTER. (NOTE: THE TELEPHONE NUMBER FOR THE x SCHOOL q LEAVE THE PROJECT AREA FREE OF DEBRIS AND UNUSED MATERIAL. ALL DAMAGE OREGON UTILITY NOTIFICATION CENTER IS (503) 232-1987). EXCAVATORS MUST m ° CAUSED BY THE CONTRACTOR SHALL BE RESTORED TO AN "AS GOOD OR NOTIFY ALL PERTINENT COMPANIES OR AGENCIES WITH UNDERGROUND UTILITIES 3 IN THE PROJECT AREA AT LEAST 48 BUSINESS-DAY HOURS, BUT NOT MORE ° BETTER" CONDITION. THAN 10 BUSINESS DAYS PRIOR TO COMMENCING AN EXCAVATION, SO UTILITIES o MAY BE ACCURATELY LOCATED. / . o SW Inez St z St Sw Inez St s'.r!, °. 6. THE ENGINEER OR OWNER IS NOT RESPONSIBLE FOR THE SAFETY OF THE in CONTRACTOR AND HIS CREW. ALL OSHA REGULATIONS SHALL BE STRICTLY 5. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO UTILITIES, FEATURES, AND 111 Q p' �o o =_� a ADHERED TO IN THE PERFORMANCE OF THE WORK. STRUCTURES LOCATED ON THE SITE. LOCATE, PROTECT, AND AVOID DISRUPTION T I i OF ALL ABOVE AND BELOW GRADE UTILITIES DURING CONSTRUCTION. ° ° • SW Pembrook St 7. TRAFFIC CONTROL SHALL BE PROVIDED BY THE CONTRACTOR THROUGHOUT e o � ?' CONSTRUCTION. CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN TO CITY 6. ALL UTILITY CONSTRUCTION ON PRIVATE PROPERTY SHALL CONFORM TO THE TEMPLETON OF TIGARD FOR REVIEW AND APPROVAL PRIOR TO COMMENCING CONSTRUCTION. LATEST EDITION Of THE OREGON PLUMBING SPECIALTIES CODE. ALL UTILITY = ° n SW Pinebrook Or SW Pinebrook W ELEMENTARY ot 8. PROVIDE TEMPORARY MEASURES TO PROTECT EXISTING TRACK FROM DAMAGE DUE CONSTRUCTION WITHIN THE PUBLIC UTILITY EASEMENT SHALL CONFORM TO THE \ SCHOOL J -- y• SNI Murdock St SW Murdock St TO CONSTRUCTION ACTIVITY. ANY DAMAGE TO TRACK SUBGRADE OR TRACK STANDARD REQUIREMENTS OF THE CITY OF TIGARD. �` W o 4 SURFACING SHALL BE REPAIRED TO THE SATISFACTION OF THE DISTRICT AT NO SW=URDOCi. K STREET ^ i l /o- ° o James Templeton 7. ALL BURIED LINES TO HAVE 2 FEET MINIMUM COVER, UNLESS NOTED OTHERWISE. / o- o 10 10 Elementary School0 ADDITIONAL COST. o O s Cr 8. ALL EXISTING UTILITIES AND TIE-IN POINTS SHOULD BE CONSIDERED ACTIVE a o • UTILITIES UNLESS OTHERWISE INDICATED. o ° o s to Dr Sw GENERAL GRADING NOTES 9 rQ s �P N 9. ADJUST ALL INCIDENTAL STRUCTURES, MANHOLES, VALVE BOXES, CATCH BASINS, _ o ngSt FRAMES AND COVERS, ETC. TO FINISHED GRADE �° �p ° o o ° o o m 1. SURVEY OF EXISTING CONDITIONS PREPARED BY KPFF. THE CONTRACTOR IS 3 0 ° o ad y Marl4'0 ? ID ID %0 N .a RESPONSIBLE FOR FIELD VERIFICATION OF ALL SURVEY DATA. CONTRACTOR IS 10. CONTRACTOR SHALL ADJUST ALL EXISTING AND/OR NEW FLEXIBLE UTILITIES °� < n a n b n RESPONSIBLE FOR ESTABLISHING RIGHT-OF-WAY LINES, SLOPE EASEMENTS, AND • ° ALL HORIZONTAL AND VERTICAL CONTROL PRIOR TO CONSTRUCTION. (WATER, GAS, TV, TELEPHONE, ELEC., ETC.) TO CLEAR ANY EXISTING OR NEW v 0 / t ° ° D r`c two `m m GRAVITY DRAIN UTILITIES (STORM DRAIN, SANITARY SEWER, ETC.) IF CONFLICT " / I • SW Sattler St SW Sattler St SW Settler St SW Sattler St SW S 2. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION STAKING AND SHALL ARRANGE OCCURS. - SW Hoodview Or SW Btaebwi FOR STAKING WITH A LICENSED SURVEYOR. STAKING WILL BE REVIEWED BY - • 11. CONTRACTOR SHALL COORDINATE WITH PRIVATE UTILITY COMPANIES FOR THE • ARCHITECT FOR CONFORMATION TO DESIGN PRIOR TO CONSTRUCTION. I o SW Lodi t. INSTALLATION OF GAS, ELECTRICAL, POWER, AND TELEPHONE SERVICE. 3. ALL GRADES BETWEEN SPOT ELEVATIONS SHALL HAVE UNIFORM SLOPE UNLESS12. BEFORE BACKFILLING ANY SUBGRADE UTILITY IMPROVEMENTS CONTRACTOR SHALL SWBettflowerS1 OTHERWISE INDICATED. MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL BUILDING • o ° ° ° o ,� N SURVEY AND RECORD MEASUREMENTS OF EXACT LOCATION AND DEPTH AND ° WALLS AND DOORS. ° ° o SUBMIT TO ENGINEER AND ARCHITECT. o- y ° ° o ° t o SW Plppen Ln Ss 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF ALL CONSTRUCTION. • • The Church of ADEQUATE SHORING BRACING, TIES, AND SUPPORTS SHALL BE USED TO PROVIDE 13. CONNECTIONS TO EXISTING STORM AND SANITARY SEWERS SHALL CONFORM TO PROPER TEMPORARY INTEGRITY DURING ALL PHASES OF CONSTRUCTION. THE 2015 OREGON STANDARD SPECIFICATIONS FOR CONSTRUCTION SECTION 00490, "WORK ON EXISTING SEWERS AND STRUCTURES". GENERAL SITE ARRANGEMENT VICINITY MAP 5. ALL EXISTING LANDSCAPED AND UNPAVED AREAS WHICH ARE DISTURBED BY 14. BEGIN LAYING STORM DRAIN AND SANITARY SEWER PIE AT THE LOW POINT OF SCALE: 1" = 150' SCALE: 1" = 500' CONSTRUCTION OR EARTHWORK OPERATIONS SHALL BE HAND RAKED SMOOTH THE SYSTEM, TRUE TO GRADE AND ALIGNMENT INDICATED WITH UNBROKEN AREAS SHALL RECEIVE BARK DUST AND REPLACEMENT PLANTINGS. DISTURBED AND RETURNED ORIGINAL EXISTING CONDITIONS. DISTURBED LANDSCAPED CONTINUITY OF INVERT. THE CONTRACTOR SHALL ESTABLISH LINE AND GRADE ABBREVIATIONS PROJECT CONTACTS LAWN AREAS SHALL BE HYDROSEEDED TO REPLACE NATIVE COVER. DISTURBED FOR THE STORM AND SANITARY SEWER PIPE USING A LASER. NOTICE TO EXCAVATORS: GRAVEL AREAS SHALL RECEIVE REPLACEMENT GRAVEL OR CRUSHED ROCK AC ASPHALT CONCRETE MIN MINIMUM ATTENTION: OREGON LAW REQUIRES YOU OWNER: PROJECT MANAGER: SURFACING. 15. ACTUAL LINES AND GRADES SHALL BE STAKED BY A QUALIFIED SURVEYOR, AD AREA DRAIN N NORTHING TO FOLLOW RULES ADOPTED BY THE TIGARD-TUALATIN SCHOOL DISTRICT DAY CPM BASED ON COORDINATES, DIMENSIONS AND BEARINGS INDICATED ON THE PIANS. APPROX APPROXIMATE OF OUTFALL OREGON UTILITY NOTIFICATION CENTER. 6960 SW SANDBURG STREET 12745 SW BEAVERTON RD, #120 OH OVERHEAD THOSE RULES ARE SET FORTH IN OAR TIGARD, OREGON 97223 BEAVERTON, OREGON 97005 CONTRACTOR SHALL RETAIN A SURVEYOR LICENSED IN THE STATE OF OREGON. BLDG BUILDING OVH 6. ALL DITCHES, SWALES, GUTTERS, CONVEYANCE PIPE, DRYWELLS, ETC. SHOULD BE / CONSIDERED ACTIVE STORM CONVEYANCES UNLESS OTHERWISE INDICATED. CB CATCH BASIN P/L PROPERTY LINE 952-001-0010 THROUGH OAR TEL: 503-431-4016 TEL: 503-641-4100 16. PROVIDE SHOP DRAWINGS FOR SITE UTILITIES THAT INCLUDE SITE CIVIL, CL CENTERLINE 952-001-0090. YOU MAY OBTAIN CONTRACTOR IS RESPONSIBLE FOR MAINTAINING STORM WATER DRAINAGE AND ELECTRICAL, AND DATA LINES, CONDUIT, AND VAULTS TO ILLUSTRATE NO CO CLEANOUT PP POWER POLE COPIES OF THE RULES BY CALLING THE CONTACT: DAVID MOORE CONTACT: ANGELA CAFFREY DEWATERING OF WORK AREAS DURING CONSTRUCTION. P.U.E PUBLIC UTILITY EASEMENT CONFLICTS. REFINEMENTS TO UTILITY LAYOUT AND DIRECTIONAL BORING CONC. CONCRETE PVC POLYVINYL CHLORIDE CENTER. CIVIL ENGINEER/PROTECT MANAGER: ARCHITECT: 7. DURING WET WEATHER PERIODS, CONTRACTOR IS RESPONSIBLE FOR SEQUENCING ALIGNMENTS CAN BE CONSIDERED, PROVIDED THAT LATERAL SERVICE COTG CLEANOUT TO GRADE RD ROOF DRAIN (NOTE: THE TELEPHONE NUMBER FOR OFFICE COPY CONSTRUCTION IN A MANNER TO MINIMIZE IMPACT ON OPEN EARTHWORK AND CONNECTIONS CAN BE ACCOMMODATED AT THE MODULAR UNITS, AND A MINIMUM CP CONTROL POINT R.O.W RIGHT-OF-WAY THE OREGON UTILITY NOTIFICATION KPFF CONSULTING ENGINEERS DOWA COMPACTION OPERATIONS. PIPE SLOPE OF 0.5% IS MAINTAINED ON GRAVITY LINES. DIP DUCTILE IRON PIPE S SLOPE (FT/FT) CENTER IS (503)-232-1987). 111 SW FIFTH AVENUE, SUITE 2500 907 SW STARK STREET E EASTING SO STORM DRAIN I PORTLAND, OREGON 97204 PORTLAND, OREGON 97205 8. ALL EXISTING MONUMENTS SHALL BE PROTECTED DURING CONSTRUCTION. IF ANY EXIST./EX EXISTING SDMH STORM DRAIN MANHOLE POTENTIAL UNDERGROUND FACILITY OWNERS TEL: 503-227-3251 TEL: 503-226-6950 MONUMENTS ARE DISTURBED OR DESTROYED DURING CONSTRUCTION, FDC FIRE DEPARTMENT CONNECTION SHT SHEET CONTACT: PAUL DEDYO CONTACT: REBECCA STUECKER CONTRACTOR SHALL RETAIN THE SERVICES OF A REGISTERED LAND SURVEYOR TO SURVEY NOTES FG FINISH GRADE SS SANITARY SEWER m RESTORE THE MONUMENT TO ITS ORIGINAL CONDITION AND FILE THE NECESSARY 1. CONSTRUCTION LAYOUT (ALL ACTUAL LINES AND GRADES) SHALL BE STAKED BY FH FIRE HYDRANT SSMH SANITARY SEWER MANHOLE Dig Safely, ELECTRICAL ENGINEER: CITY OF TIGARD a SURVEYS AS REQUIRED BY STATE LAW. A PROFESSIONAL SURVEYOR, REGISTERED IN THE STATE OF OREGON, BASED ON GND GUTTER FOUNDATION ST STREET Call the Oregon One-Call Center PAE ENGINEERS REVIEWED FOR CODE COMPLIANCE o COORDINATES, DIMENSIONS, BEARINGS, AND ELEVATIONS, AS SHOWN, ON THE STA STATION 522 SW 5TH AVENUE, SUITE 1500 9. COMPLETELY COVER ANY SOIL STOCKPILES WITH 6 MIL BLACK PLASTIC AND PLANS. GB GRADE BREAK STD STANDARD 1-800-332-2344 Approved: I > PROVIDE RESTRAINTS TO HOLD PLASTIC IN PLACE. MONITOR PLASTIC COVER AS GL GAS LINE TC TOP OF CURB PORTLAND, OREGON 97204 OTC: [ I PART OF CONTINUOUS EROSION CONTROL PLAN. PLACE SILT FENCE COMPLETELY 2. PROJECT CONTROL SHALL BE FIELD VERIFIED AND CHECKED FOR RELATIVE GV GATE VALVE TG TOP OF GROUND TEL: 503-226-2921 I AROUND STOCKPILE. HP HIGH POINT TP TOP OF PAVEMENT EMERGENCY TELEPHONE NUMBERS CONTACT: MICHAEL LOPEZ Permit#:_S I 1 O 1 R 00 D d HORIZONTAL POSITION PRIOR TO BEGINNING CONSTRUCTION LAYOUT. SEE SHEETS Address: y C,1 ,SO ° C2.1 FOR PROJECT CONTROL INFORMATION. IE INVERT ELEVATION TYP TYPICAL 0 10. TEMPORARY AND PERMANENT EROSION CONTROL MEASURES SHALL BE INV INVERT W WATER NW NATURAL GAS SHEET INDEX Suite#: IMPLEMENTED. THE CONTRACTOR SHALL ADHERE TO CLEAN WATER SERVICES3. PROJECT CONTIRR. IRRIGATION WV WATER VALVE _ ___ ____ Data _ CONTROL SHALL BE FIELD VERIFIED AND CHECKED FOR RELATIVE M-F lam-bpm 503-226-4211 Ext.4313 Sheet BY' " i STANDARDS FOR MINIMUM EROSION CONTROL MEASURES. THE ESC FACILITIES VERTICAL POSITION BASED ON THE BENCHMARK STATED HEREON, PRIOR TO LP LIGHT POLE AFTER HOURS 503-226-4211 o SHOWN IN THESE PLANS ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED BEGINNING CONSTRUCTION LAYOUT. MH MANHOLE Number Sheet Title PGE503-464-7777 SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, ESC FACILITIES SHALL BE CO Cover Sheet UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT CENTURYLINK 1-800-573-1311 0 4. WHEN DIMENSIONS AND COORDINATE LOCATIONS ARE REPRESENTED - C2 Site Plan Q SEDIMENT AND SEDIMENT LADEN WATER DO NOT LEAVE THE SITE. DIMENSIONS SHALL HOLD OVER COORDINATE LOCATION. NOTIFY THE CIVIL CITY BUREAU OF MAINTENANCE 503-823-1700 0 C3 Grading Plan 0) ENGINEER OF RECORD IMMEDIATELY UPON DISCOVERY. CITY WATER 503-823-4874 11. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL ROADWAYS, KEEPING VERIZON 1-800-483-1000 C4 Utility Plan - m THEM CLEAN AND FREE OF CONSTRUCTION MATERIALS AND DEBRIS, AND CS Details 0 PROVIDING DUST CONTROL AS REQUIRED. C6 Erosion and Sediment Control Plan C6A Erosion and Sediment Control Details 0 12. RESTORE DISTURBED AREAS FROM UTILITY TRENCHING AND AFFECTED AREAS :2 ALONG NEW ASPHALT AND GRAVEL SURFACING TO MATCH GRADES AND BLEND A1.0 Code Analysis n IN WITH ADJACENT LANDSCAPING. F1 Classroom Foundation Plan & Details FIA Restroom Foundation Plan & Details Rl ADA Ramp Plan & Details o a R2 ADA Ramp Plan o I o E1 Symbols, Legends & Abbreviations o E2 Site Plan - Power (n T m E2A One-Line Diagram - Electrical _ ,� E E3 Details - Electrical o' o V) E3A Schedules - Electrical 0 o ADD-03 Issue Date : 03/09/2018 %o cc ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMSJ PRCFFS JOB No.: 1700395 9500 SW MURDOCK,TIGARD, OR 97224 j00 V\`�� O t N F s/O DESIGNED BY: J. ADAMS TTSD MODULAR CLASSROOMS ADD-o3 79701 PE DRAWN BY: R. CADUA TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS O / - z 0 111 SW Fifth Ave., Suite 2500 .r/ CHECKED BY: P. DEDYO CITY OF TIGARD, OREGON Portland,OR 97204 OREGONpqTE: 03/09/2018 0 p i>- FO: 503.224.4681 ,O 7Ur. 10, 11� PLOTTED BY: PDedyO SHEET OF co www.knlf.com MARKD1700395-COV.dw COVER SHEET RECORD N0. 7 a DWG NAME: 9 N REVISION DATE DESCRIPTION BY EXPIRATION DATE t8/3V3o19 TAB NAME: CO 1700395-XX 9� a pEE Hill - -Lm }o 0 D TWALITY MIDDLE SCHOOL AUXILIARY GYM om m 1� \ 0 30.06 36' 18'— 36' 22'--j Im N=132431.94 E=321781.90 N=132467.32 ' . '. 0 FUTURE PHASE — — — E=321801.12Ln CIDO LO f0 w R1 R2 1 R3 `r? ■ 14'-11 ■ r ■ r • ---- � ® 1 � '� �� I 93.08'- AS 3.08' AS'ALT OVERLAY N=132502.94 7 _ N=132877.52 0 TRANSITION E=321862.71 ---- GRAD .'< ' 1-E=321990.86 •. ::' 1 -' �: : . .:: . I 20' 20' f'": ! x' N o :; •t 't I •t.' . . .. •• ' '' .. CLR . .. t. BETWEEN BETWEEN �••" 9• �� • UNITS UNITS `•t' ? t •*!�. ' �, i : t'• r .j s 10 !.• 10 r - t I t-: 10 0 10 ... r o'r 2 .0 •l/• • t- : 76.13 . •' : : :. . 76.13 . 76.12 . ;'• t .• u7 •, n { n 0 P1 P1 P1 _ t 1 2 3 a ! - ••l 4. 4" 4• 4" 4 5 t.�• 't I Y ..r} 2 Pi P2 P4 P5 P7 P8 r .•t, OWNER FURNISHED .. . . �• •. is �.�. •. :. '. .. �:. ' C. ',. • '• .r. t.• £•: C D WALKWAY ONTAINERS l L '• J Hm I 6. 6, 6, I ® N=132486.85 : :r CLR ': . ': CLR ` r CLR -• ♦ N=132727.25 d; ASPHALT OVERLAY ,�1 0 E=321941.23 BETWEEN..' ' ' ., .. TO TRANSITION m - BETWEEN,' ' '•r: 'BETWEEN.-` ' ' I E=322060.54 I GRADES C UNITS b UNITS e. • UNITS n- n� .P3 4 . �;.•; -.f •P6 - 4 . "y : -.'r P9 .. 4 ';• F O \ ° � � ❑ °� d �F� 13.06' 70' 16.13' 70' 16.13' 70'' _ \ o cp- w cp- 0 o sp d% `'o Ps D' SCALE 1 INCH = 20 FEET 20 0 20 40 a SHEET LEGEND O KEYNOTES SHEET NOTES 3 — — PROPERTY LINE # DESCRIPTION 1. SEE SHEET CO FOR ADDITIONAL SURVEY NOTES REGARDING o LAYOUT. V GRAVEL BASE 1 ALIGN PATHS ACROSS TRACK 1 S'1 2 ASPHALT PATHWAY 2 GRAVEL,EUNLESS NOTED OTHERWISE. ASPHALT OR EDGE OF rn 0 3 MODULAR RESTROOM 3. MODULAR CLASSROOM AND RESTROOM UNITS, AND THE 4 NEW MODULAR CLASSROOM RAMPS, STAIRS, AND DECKS PROVIDING ACCESS ARE OWNER j ASPHALT PATHWAY 5 FURNISHED AND INSTALLED BY SUPPLIER. 0 5 RELOCATED MODULAR CLASSROOM 4. GRAVEL BASE PADS ARE SIZED TO ACCOMMODATE ASPHALT OVERLAY FOUNDATION COMPONENTS FOR MODULAR UNITS AND 5.1 ASSOCIATED ACCESS RAMP, STAIRS, AND DECKS. 5. FINAL CONFIGURATION OF RAMPS, STAIRS, AND DECKS MAY o a MODULAR CLASSROOM ID VARY TO MEET ADA ACCESS REQUIREMENTS. P=CLASSROOM 6. MINOR ADJUSTMENTS TO GRAVEL BASE PAD SIZE MAY BE 0 R=RESTROOM REQUIRED IN COORDINATION WITH MODULAR BUILDING c ® INSTALLER. � TREE TO BE REMOVED 7. PROTECT EXISTING TRACK SURFACING FROM DAMAGE DUE TO C) CONSTRUCTION ACTIVITY. - T o -o 3 0 0 I d 0 � T ~ m • � d o ADD-03 Issue Date: 03/09/2018 %o ro ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMS ��CD �Ep PROFFJ Ir/1 JOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 j\ �V\S�a� 1 N FF9�O,yq DESIGNED BY: J. ADAMS TTSD MODULAR CLASSROOMS 79701 PE l DRAWN BY: R. CADUA TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS ADD-03 i� � CHECKED BY: P• DEDYO CITY OF TIGARD OREGONC 2 111 SW Fifth Ave.,Suite 2500 o Portland,OR 97204 OREGON DATE: 03/09/2018 0:503.227.3251 d F: 503.224.4681 P '7G<, IU 1�®� n www.kvlfxom •4 PLOTTED BY: PDedyo SHEET OF N U� MARKpY�� DWG NAME: 1700395-SITE.dwg SITE PLAN 2 RECORD NO. REVISION DATE DESCRIPTION BY exFirsnrioN Dare: U/7V70■ TAB NAME: C2 1700395-XX \ -275' / -275- �� ' 275- o v • �/ zm ° J �` -�/'-\x-275 \ $1 TWALITY MIDDLE SCHOOL AUXILIARY GYM _- -- \\ --_---- ---- - -- -- --- -'.275------------------------- \ �\ \ --- - 10 /-�\ \\ <o ® /- r - - - - - - - - - - - - �/ \` - - '274- - - -- -- - - - - - - - - - - - -- -- -/ \ - - 274--\ MATCH TOP OF a // 274- CURB ELEVATION / _ - -- - --' \ \ 273.65 274.20 _ _ - 274.75 FUTURE PHASE 5.h 1.4% I - - - - - 7g: -< :t•: i \ \ \ - - - - 4 � 275.33 / � ": ` .: :• ` .: r •i, •••: \ \ 273.571 274.90 274.46 274.15 \ \ _ >2 ` \\ 275.30 / 274.15 ■ ■ ■ Y � • II�� \\ 1 \ I 274.93 MATCH DECK ELEV / / in OF COVERED WALK 8` WIDE PATH MEETING / / I / 2 274.38 274.00 274.00 -ADA REQUIREMENTS \ 01 \ \ 1 1 1 I / -'• � `'•.. ::.. •. r• •: •. :t. r •. J• •r.. : ` •: '_: '•. •:. • •T+ - 273 �.�-�=• -r:-�^! •- ..t : : .r• f• \ \ o / . -273.90*.- 'r !. + 273.90' 273.90 '. - . 273.90 273.90 ` •:. . •.273.90 _ , : + /. . •. •. ;' : •r °.,• 's '., •s :� 'r .r •sem.--- - T.-:'. - - - .- �,. •.•� w .•J '.i• \ I 1 N ` i•• J•: A \ T .i'• I .f•• Il 1 I g•r I t.• J. -270- .2w \ r• 0- \ I - I - _ •i •i i• .. i _ r• -j : T I / I f• \ j:. r � t •< / I I w•t� •t m t � I': ,' : i.." + '•f I •. t .t• � I I I I I K •! � !. .Y•.. 2 1 / r •r .'I Ln v 1 I[1 'r• .s' .. 1 o .r I � =k •r• { W I I 1 I I t� a I 1 I • I t I " Y• I ' r.• ''r I I 1 \ • w r i , 'f• •f I . I I r r n'f . i. l •+r . ..i. t•• \ 1 .. t .. .. I •� I I I I I ••T . • i - • •J• • I I ,•I• I \ I I ••t. J• / / / MATCH DECK ELEV \ � � ••• '• _' •• •' 272.93 . 272.92 272.92 ` i: . : . :':: .. .' : • ' ••. •, .. 2 t : '. . / / 1 OF COVERED WALK- MATCH ALK : is I I+. I ': . :r's I :. •." :. •., : ' .� / I 272.92 •''. 272.92 .. .. 272.92 . 272.92 }'.. 272.92 272.92 272.92 . 272.92 ' ., .' 272.92 `.: _ ':. ' :.; , :_ • . : :•'• I / / / / /�I \` \ \ \ \ r `��• 72.85. - •.� �• -::� �.:r, ,,� � i�:,�, b // // / / / / � 1.5X 1.5X 1.5% RAMP MEETING \ \ \ \ \ 272.85 °272.85 ;. : : . 272.85 272.85 :.. :•:272.85: :272.85 -272 ADA REQUIREMENTS \ r✓1 \\\ \ \ \ \\ `-:272 .__ , . ` a .. :}• •:t / / !Jt !t• \ / � . \ -272- - � '- - - - - - - - - - \ - - - O - � ' \\`- - - - - - - - - - -'_ _ - - - - `\\ \ � \ SEE SHEET NOIE 8 _ � _ � _ - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - -- - - 2- - - - - - - -- - - - - - - - - -- - - - -- - - - - - - -- - - - - - -273- - - -274- - - moi' ---/� \ .o tip \ - - - - - - - - - - - - -- - -- _ - --- - - - - - - - - ----------- \ \ mm- 26 \ ?6 \2� \\ \\\ \\\-275-- 0. m \ d11 - _ \ _ 1270 267/ --� -- - - 265-- -- - - - - - - --- -- -- - - - - - - - - - - -v- - �-- - - ----- _ _ - - _ f I ----- ---• - - - - P _ - __ ,yo m ^ I NyF I \- - - - - - - - - -- -- -$ -� - - - - --- - -.- - - -sem - - - - -- -. - .-- - -- _ - - - - - - - - -SCALE- 11NCH 2O FEET \?6>� • �� `\\\ \ \ II, //'/ - - - - - - - _ _ - �2 °1 20 0 20 40 Q SHEET LEGEND GRADING LABEL LEGEND SHEET NOTES 66 ~ „w.� DRAINAGE FLOW DIRECTION CALLOUT DESCRIPTION 1. SEE SHEET CO FOR ADDITIONAL GENERAL GRADING NOTES. o, - - -- - -49- - - - EX. CONTOUR MINOR 2. SLOPES PROVIDED ON SLOPE ARROW ARE FOR REFERENCE ---- -50---- - EX. CONTOUR MAJOR X Xy GRADING SLOPE AND DIRECTION (DOWNHILL) ONLY. SPOT ELEVATION 3. LANDINGS ON ACCESSIBLE ROUTES SHALL NOT EXCEED 2% DESCRIPTION LISTED BELOW. IN ANY DIRECTION. 0 NO DESCRIPTION MEANS TP OR TG 4. ALL ACCESSIBLE ROUTES SHALL COMPLY WITH CURRENT ADA o �XX.XX XX ACCESSIBILITY GUIDELINES FOR BUILDING AND FACILITIES j TC TOP OF CURB (ADAAG). a TG TOP OF GROUND TP TOP OF PAVEMENT 5. GRAVEL BASE PADS DO NOT HAVE TO BE LEVEL, AND CAN FOLLOW EXISTING SLOPES. rn m r(XXX.X±) EXISTIN(MATCHG GRADE APPLICABLE) 6. UNDER MODULAR CLASSROOM UNITS, ADJUST FINISH GRADE o OF GRAVEL BASE PADS TO DIRECT SURFACE RUNOFF UNDER ELEVATED DECK AT GAP IN ASPHALT PATH, AND TOWARD 0 EXISTING DRAINAGE STRUCTURES. 7. UNDER MODULAR RESTROOM UNITS, ADJUST FINISH GRADE 2 OF GRAVEL BASE PADS TO DIRECT SURFACE RUNOFF NORTH 0 OR SOUTH TOWARD AREA DRAINS. = T O � 8. ADJUST GRADING OF LAWN ON UPSLOPE SIDE OF MAIN ASPHALT PATH TO DIRECT SURFACE RUNOFF TO NEW AREA 51 DRAINS. � m E 9. ADJUST EMBEDMENT DEPTH OF GRAVEL BASE SECTION TO M N MAINTAIN SURFACE RUNOFF TO EXISTING DRAINAGE o STRUCTURE. ADD-03 n Issue Date: 03/09/2018 0 o ^ ao ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMS J C) � \��Ep pRpFFSJ' JOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 cq V\S O 1 N F /O DESIGNED BY: J. ADAMS 79701 PE 9 y9l DRAWN BY: R. CADUA TTSD MODULAR CLASSROOMS ADD-03 TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS / - CHECKED BY: P. DEDYO CITY OF TIGARD OREGON z 111 SW Fifth Ave.,Suite 2500 OREGON C3 03/09/2018 --• Portland,OR 97204 DATE: ui a 0:503.227.3251 ji 0- F: 503.224.4681 A !G�• 10 2® 0 PLOTTED BY: PDedyO SHEET OF M www.koffrom 9U/ MARKp� GRADING PLAN 3 v DWG NAME: 1700395-GD.dwg RECORD NO. a EXPIRATION DATE: 12/31/2019 C3 1700395-XX REVISION DATE DESCRIPTION BY TAB NAME: OHU z I I� � } ° P° s, z p S, N - - O o [ss] fss] [ss] -- [ss] [ss] - so [® [ss] - po: TWALITY MIDDLE SCHOOL m AUXILIARY GYM SO COTG-20 SD COTG-21 SO COTG-22 SD COTG-23 0 4 IE 4" OUT=271.86 (SE) IE 4" OUT=272.01 (SE) IE 4" OUT=272.11 (SE) IE 4" OUT=272.31 (SE) / s. 33 LF - 4"SD 33 LF - 4"SD - 33 LF - 4"SD - 33 LF - 4"SD S=2.24% �- S=2.27% S=2.34% S=2.22% m 4" STUB TO SD COTG-24 SURFACE FOR IE 4" OUT=272.31 (SE) �oyc " A DOWNSPOUT, TYP. 33 LF - 4"SD 4" STUB TO CONNECT TO EXISTING 8 SANITARY _ S=2.00% SURFACE FOR O IE 6" IN=266.90 (NE) `y MANIFOLD OF (5) 1" WATER SANITARY, TYP. 4' SERVICE LATERALS TO EACH II FUTURE PHASE MODULAR RESTROOM WITH GV II S COTG-27 \ IE 6" our=269.27 (SW) \ yc B 2" GV SD AD-13 w w w w w' S=1.00% mss, w, - `s, 1 237 LF - 6"S SD AD-14 IE 4OUT=271.50 E O SO AD-10 S=0.50% 5=0.50% " ( ^ RIM=272.75 " 72 LF - 4"SD ) w. IE 4" OUT=272.12 (NE) 108 LF - 6 SD �G 15 LF - 4"SD SD AD-11 \_SD COTG-25 I 'I _ S=6.57% RIM=273.00 IE 4" IN=271.64 (NW) k P �� __ IE 4" OUT=272.00 (SE) IE 4" IN=271.64 (NE) ISS- \ 3 - 4"SD IE 6" OUT=271.55 (SW) a"� 1- F_ S=11 9.82% SD COTG-26 SD AD-12 -- __ IE 4" IN=271.11 (NW) RIM=273.00 ° IE 6" IN=271.01 (NE) IE 4" OUT=272.00 (SE) IE 4" IN=271.11 (SW) 3 LF - 4"SDcn I I o ws ZF io IE 6" OUT=271.01 (SE) S=10.11% I ( I FL ° Ln -- N cp, 235 LF - 2"W-,,,,,,-' I I II I I I � I I I I I I I i I d�. G7 y tp sN Ot DOWNSPOUT SPLASH PAD, �G2 ?, °� CONNECT TO EXISTING CB TYP. Q`-° `n IE 6" IN=270.50 (NW) I O I No �O -'- _-- w [ D] [SDI [SD] [SD] [SDI [SDI - [SDI -[SDI [SDI [sDI [SDI [SDI [SDI -- [SD[ [SDI [Sol CONNECT TO EXISTING CB � � ,2 /G IE 4" IN=270.50 (W) B m, yo cF � Nf \ o r A CIS% cp o n 1 0 0 0 wo e-a , Yo m, ro SCALE 1 INCH = 20 FEET CO 20 0 20 40 m UTILITY LABEL LEGEND O UTILITY KEY NOTES SHEET NOTES Q 3 STRUCTURE LABEL STRUCTURE TYPE NOTE DESCRIPTION 1. SEE SHEET CO FOR ADDITIONAL GENERAL UTILITY NOTES. UTILITY TYPE (SD=STORM DRAINAGE, S=SANITARY CALLOUT DESCRIPTION DETAIL REF. FIELD VERIFY LOCATION AND IE OF EX LATERAL 2. ON-SITE PIPE BEDDING AND BACKFILL FOR ALL UTILITIES SHALL SD STRUCTURE TABLE SEWER, W=WATER, FP=FIRE PROTECTION) AD AREA DRAIN 5/C5.1 1 PRIOR TO CONSTRUCTION BE DONE PER DETAIL 4/C5.1. STRUCTURE TYPE CALLOUT COTG CLEANOUT TO GRADE 6/C5.1 CONNECT TO COLD WATER SYSTEM. SEE PLUMBING NO STRUCTURE ID NORTHING EASTING XX XX-XX ID NUMBER WHERE APPLICABLE GV GATE VALVE W PLANS FOR CONTINUATION. SIZE AS NOTED. ( ) 3. COORDINATE LOCATION OF UTILITY LATERAL STUBS SERVING AD-10 132540.59 321864.62 N=XXXX.XX ]- LOCATION WHERE APPLICABLE STUB STUB B BORE UNDER TRACK TO PROTECT TRACK SURFACE RESTROOMS WITH MODULAR RESTROOM SUPPLIER. COORDINATE E=XXXX.XX ( ) UTILITY TRENCHING AND LAYOUT WITH PROPOSED ELECTRICAL o AD-11 132586.15 321887.18 RIM= AND DATA INFRASTRUCTURE SERVING NEW MODULAR UNITS. UTILITY CROSSING PROVIDE 12' MIN. CLEARANCE, J o_ IE IN = XX.X STRUCTURE INFO (WHERE APPLICABLE) II UNLESS NOTED OTHERWISE. o/ AD-12 132634.29 321911.01 IE OUT = XX.X 4. SUBMIT SHOP DRAWINGS TO ILLUSTRATE COORDINATION OF AD-13 132714.68 321950.82 PIPE LABEL UTILITY TRENCHING AND LAYOUT WITH PROPOSED ELECTRICAL AND DATA INFRASTRUCTURE SERVING NEW PORTABLES. AD-14 132835.19 322010.29 UTILITY LENGTH ED I o COTG-20 132567.40 321844.29 UTILITY SIZE D o COTC-21 132601.26 321861.06 XXLF - XX" XX --UTILITY TYPE (n COTG-22 132615.79 321868.25 S=X.XX% SLOPE (WHERE APPLICABLE) o COTG-23 132649.65 321885.02 0 3 COTG-24 132663.95 321892.10 � o a 0 COTG-25 132649.25 321921.77 n >, °' COTG-26 132552.73 321873.98 E M N COTG-27 132675.43 321922.74 o ADD-03 00 Issue Date : 03/09/2018 %o m ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMSJ / BRED PROFFS JOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 N V\5� ° IN SAO DESIGNED BY: J. ADAMS �\ `�79701PE 9 y9l DRAWN BY: R. CADUA TTSD MODULAR CLASSROOMS ADD-03 TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS C4 Z 111 SW Fifth Ave., Suite 2500 � - CHECKED BY: P. DEDYO CITY OF TIGARD, OREGON Portland, OR 97204 OREGON pq�: 03/09/2018 O o 0:503.227.3251 i d F: 503.224.4661 A �U[ Ip 101 www.koff.com 9 PLOTTED BY: PDedyo SHEET OF N U� MARKD��� DWG NAME: 1700395-UTIL.dwg UTILITY PLAN 4 RECORD NO. REVISION DATE DESCRIPTION BY ExP1 TION;ATE: t4/300M TAB NAME: C4 1700395-XX [MEDIUM DUTY 15"± 3- 1/2- DENSE GRADED LEVEL 2 HMAC TOP OF PAVEMENT SQ. TRAFFIC GRATE. 3" MIN RIM=PER PLAN 8" MIN COMPACTED WIDTH (WHERE TOP OF GROUND SHOULDER BASE COURSE APPLICABLE) (WHERE APPLICABLE) PER PLAN EX. GRADE . . . . . . . . . . . t t 0° 000 *0 .•00.0 . 0 '000 0 ENGINEERED FILL PIPE SIZE APPROX. -'5"-4- 0.0.1., -.010 1. '0'0 PER PLAN STRIPPING DEPTHep• '0 L 11 L 11�l 3- NOTE 1 12" T COMPETENT, GEOTEXTILE COMPACTED 12m IE PER SUBGRADE PLAN 4" COMPACT SUBGRADE 1111V 11111 W�7\/\ 1 ASPHALT PATHWAY NOTE SCALE: NTS 1. 10 GAGE STEEL PLATE, BITUMINOUS COATED, AS MANUFACTURED BY GIBSON STEEL BASINS OR APPROVED EQUAL. AREA DRAIN SCALE: NTS 6" MIN COMPACTED BASE COURSE HARD SURFACE LANDSCAPE AREA — ,' �0 --- —EX. GRADE 00 0 0 0 0 0.4 .0 00 0*4 0 0 0, CAST IRON FRAME AND MECHANICAL PLUG APPROX. 0 0 .01.%.. . . .0.0 4. 0--0.0 00 00 . 00 Y-4- '0 COVER TO FINISHED WITH GASKET STRIPPING DEPTH GRADE IN PAVED AREAS RISER O.D. CAST IRON FRAME AC PVM'T OR CONIC. PAVING y2- MIN SET IN CONCRETE COMPETENT, GEOTEXTILE OR OTHERSURFACING COMPACTED SUBGRADE Ll" MAX. 2" MIN. c '- AII= GRAVEL BASE • #4 HOOP 5- MIN. .0 9:' CENTERED IN 3000 NTS . 0 A' I I 1—PSI CONCRETE PAD. 0 oe 4" MIN. PROVIDE Y4" MIN. CLEARANCE FOR CONCRETE PAD 1/2- DENSE GRADED, AND RISER PIPE LEVEL 2 HMAC. ----� PLACE IN 2" MIN OR 4" MAX LIFTS. 000.0 L RISER PIPE o•°0 .00- 00 .0.c TRENCH BACKFILL EXISTING ASPHALT .-. 0 , e0 '60CEIN .0 N W < N 0 WYE BRANCH 0,,.0 45* BEND *.c CARRIER 0100*1. PIPE a 0-.%." INSTALL PLUG WITH GASKET IF END OF LINE ASPHALT OVERLAY .0 SERVICE CONNECTION .0 . 0 .'.. .0. SCALE: NTS 0 0 ' 0 0. IF REQUIRED 0 . .0 BEDDING MATERIAL NOTES RESURFACING MATCH 1. CAST IRON FRAME AND COVER SHALL MEET H-20 LOAD REQUIREMENT. EXISTING PAVEMENT PAVED UNPAVED SECTION AREAS AREAS 2. FOR CARRIER PIPE SIZE 6"0 AND LESS, PROVIDE RISER PIPE SIZE TO MATCH EXISTING AC—\ SAWCUT —\ DETECTABLE CARRIER PIPE. PAVEMENT LINE WARNING TAPE 3. FOR CARRIER PIPE SIZE 8"0 AND LARGER, RISER PIPE SHALL BE 6"0. 4. RISER PIPE MATERIAL TO MATCH CARRIER PIPE MATERIAL.< 0 0. *.a ,* CLEANOUT (COTG) 0 f7N , m0 12" 0 x X SCALE: NTS 0 V) 0 —j C) z < U- > z < < cn 01 IL m x U) co z n 01 a- 0 0 Li .0".0 ..'*.0: 0 /\TRACER WIRE 0 < 0 u- °o ,eea -.0*0 m -j LU 12" 0 •eo ..0*00; ;i 0 < D/2 00 0 0. 0 -.0 . f z .0..0 Q 0 m U) 0 6- D 6- o MIN. MIN. cf) 51 TYPICAL AL PIPE BEDDING AND BACKFILL Ty'l E SCALE�TS LOQ 0) CN ro 0 0 .. ADD-03 Issue Date : 03/09/2018 00 ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMS 0 PROFSJOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 'SA N I N 4F DESIGNED BY: J. ADAMS TTSD MODULAR CLASSROOMS 7 701 PE DRAWN BY: R. CADUA TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS ADD-03 111 SW Fifth Ave.,Suite 2500 CHECKED BY. P. DEDYO CITY OF TIGARD, OREGON C5 Portland, OR 97204 OREGONDATE: 03/09/2018 0:503.227.3251 L,- a_ F: 503.224.4681 10 10, I PLOTTED BY: PDedyo SHEET OF www.kpff.com 90� NARK DETAILS 5 DWG NAME: 1700395-DTLS-dwg RECORD NO. REVISION DATE DESCRIPTION BY EXPIATION DAT�E 12/3V209 TAB NAME: C5 1700395-XX 2�5— O U / —275' _275— z o / 27 y — [ss] ��_[ss] [ss] [SS] ssE [ss�— [ss] \ TWALITY MIDDLE SCHOOL \\ i G AUXILIARY GYM ` \y -- ----- --------- \ ° \ --- --- -- --------- ---- 10 m / _ _ _ — — — — — — — — — — — / / \ / \ \ — — ° /27yi / - - _ � - - - 274- - - - - - - -- '- - 274- - \ 274– \ / \ ` \ / - - - - - - Uk 4' \ 2� TQv�`y / / / FUTURE PHASE — — — _ \ `\\ s\ Kz - - - - SG v/ - -274 1 - - - -N — 74- - / M 1 1 \ \ \ Ir�'2 LEE e FI:E M / / EE 1 \ i - - - o - / I / --- _._- — - - - - 273 8'SS --270 �,. '\ \ 2 3- — — — - -- w - - , \ - _ _ - _ - - _ - 2 Lq \ , I // ,1 I \'`\ 2619 Ll I - 1 / 272- - - - - - _ 272 up VA I Ol [SO] [$D] —[SDI� / ISD] [$D] \ ISD] [SD] —yam—[ — [SD —[SDI ISD] [SDI [SDI -... [SD] \\ I50] - - - - - - - - - - - - - - - - - G - - - - - - - - - - - - - - - - - - - - - - - - - - -#"G- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -273- - 26>� — ---- — _ // / - - - - — / � \ e': - - - _ -_�� ._ _ _ --- --- •270 — _ ''— — — - - - — - - - - — — _ - - — — - -_ --- -- -- - __-- _ � �� �- � ��./ - - - - - - - - J '''n= if �4 267 I i\� - - - - - - - - --- -// - - - -SCOL-E - 1INCH = 20 FEET - - - - - - - - - - - - - _ _ 20 0 20 40 – \ \ c / -> > // - - - - - - - - - - - - -zfi7 - �ZF c �` EROSION CONTROL LEGEND SHEET NOTES t- 01 LIMITS OF DISTURBANCE SHOWN 1. APPROVAL OF THIS EROSION/SEDIMENTAT]ON CONTROL (ESC) 4. CONTRACTOR TO COMPLY WITH EROSION CONTROL NOTES ON OFFSET FOR CLARITY PLAN DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT COVER PAGE FOR MINIMUM EROSION CONTROL REQUIREMENTS 0- / ROAD OR DRAINAGE DESIGN (E.G., SIZE AND LOCATION OF AND INSPECTIONS. N P° \ v� w�ti / — " — 164 — EX. CONTOUR MINOR ROADS, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES, ETC.). 5. DISCHARGE POINT FROM THE FIELD SITE IS SOUTH TO THE 165 — — EX. CONTOUR MAJOR CONVEYANCE SYSTEM THAT ENTERS THE PUBLIC STORM M 2. THE IMPLEMENTATION OF THESE ESC PLANS AND THE SYSTEM AT THE EAST EDGE OF THE TEMPLETON ELEMENTARY o 0 0 PERIMETER CONSTR. FENCING CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING SCHOOL. OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE o TREE PROTECTION FENCING CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND 6. TREE ROOT REMOVAL MAY INTRODUCE UNANTICIPATED SOURCE J (REF. LS PLANS) APPROVED AND PERMANENT VEGETATION/LANDSCAPING IS OF SEDIMENTS. CONTRACTOR USE CAUTION AND PROPERLY j ESTABLISHED. DISPOSE OF TREE ROOTS OFF SITE WITHOUT ALLOWING ANY SW ( 7 ?j STRAW WATTLE 1 SEDIMENTS FROM LEAVING THE PROJECT LIMITS. 6.2 3. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE DRAINAGE FLOW DIRECTION (EX) CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND 7. TREE REMOVAL AND TREE PROTECTION FENCING SHOWN FOR m GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO ENSURE REFERENCE ON THIS SHEET. SEE LS PLANS FOR ADDITIONAL +► DRAINAGE FLOW DIRECTION (PROP) THAT SEDIMENT AND SEDIMENT LADEN WATER DO NOT ENTER INFORMATION AND TREE PROTECTION FENCING DETAILS. o THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER STANDARDS. �° ® INLET PROTECTION C62 I O TREE TO BE REMOVED 0 O 3 O I � cn >, � 0] E 'n a � N o ADD-03 Issue Date : 03/09/2018 %o a 00 ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMS \BRED PROFESS JOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 j00 V\5 GINE /O DESIGNED BY: J. ADAMS k aF �y TTSD MODULAR CLASSROOMS 79701 PE 9 l DRAWN BY: R. CADUA ADD-03 TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLSC 6 --- P. DEDYO z 111 SW Fifth Ave., Suite zsoo .�� CHECKED BY: CITY OF TIGARD, OREGON Portland, OR 97204 OREGON DATE: 03/09/2018 N o 0:503.227.3251 i� El- F: 503.224.4681 ,o ". fo, 1,P p PDedyo SHEET OF n www.koF.com q�! MARKD�- PLOTTED BY: EROSION AND SEDIMENT CONTROL PLAN 6 a DWG NAME: 1700395-ESCP.dwg NRECORD N0. 77 REVISION DATE DESCRIPTION BY e 7771ON 77E. 12/30= TAB NAME: C6 1700395-XX 0 o o m " A z WOOD STAKE (TYP.) A ADJACENT ROLLS SHALL TIGHTLY 4 yo � ABUT o (1\9�0 ��., ' J PLAN VIEW WOOD STAKE (1" SQ. MIN.) STRAW WATTLE (8"-10° DIA.) INBED WATTLE 3"t INTO P EXISTING GROUND SURFACE i� TO PROVIDE CUTOFF EXISTING SLOPE SECTION 'A' NOTES: 1. STRAW WATTLES TO BE PLACED ALONG SITE CONTOURS. 2. HORIZONTAL SPACING VARIES DEPENDING ON SOIL TYPE AND STEEPNESS, SEE PLAN (5' MIN - 25' MAX.) 3. RUNOFF MUST NOT BE ALLOWED TO RUN UNDER OR AROUND ROLL. 4. STRAW WATTLE SHALL BE RICE STRAW ONLY. USE OF FIBER ROLLS, WHEAT GRASS, OR RYE STRAW NOT PERMITTED. STRAW WATTLE ON SLOPE SCALE: NTS 2 EACH FOAM DUMP STRAP EXPANSION RESTRAINT (Ya" NYLON ROPE, 2" FLAT WASHERS) DUMP STRAP 1" REBAR FOR BAG BAG DETAIL REMOVAL FROM INLET a - Q REGULAR FLOW SILTSACKO DUMP STRAP 3 !n o Dep�\o D_ U N W M V"O O i <F O a d < ed. U a . a. e U d 0] i NOTE: 0 1. DO NOT USE HIGH FLOW INSERT BAGS. 7L—, INLET SEDIMENT PROTECTION o � o SCALE: NTS la 0 U T � m E In d mN 0 .. ADD-03 0 'j- Issue Date : 03/09/2018 %o oo ADD-03 3/9/18 ADDENDUM 3 MODULAR CLASSROOMS Q\ ���ED PROFFS JOB No.: 1700395 9500 SW MURDOCK,TIGARD,OR 97224 C\j EF yy TTSD MODULAR CLASSROOMS U �5 g 1 N �O DESIGNED : J. ADAMS TWALITY MIDDLE AND TEMPLETON ELEMENTARY SCHOOLS Q ` 9 l R. CADUA ADD-03C6A 7J701PE DRAWN BY: 111 SW Fifth Ave., Suite 2500 CHECKED BY: P. DEDYO CITY OF TIGARD OREGON z �/ o Portland, OR 97204 OREGON' DATE: 03/09/2018 lq)ff 0:503.227.3251 www.kpfcom81 AgG�U�' °. 1p0��.�o PLOTTED BY: PDedyo EROSION AND SEDIMENT CONTROL DETAILS SHEET of N MARKS DWG NAME: 1700395-ESCP-DTL .dwg RECORD NO. C6A 1700395-XX REVISION DATE DESCRIPTION BY EXPIRATION DATE U/3 2019 TAB NAME: