Loading...
Report (13) &/pea/? © 3y(O Submittal Response Letter , ARCHITECTURE SERA URBAN DESIGN•PLANNING INTERIOR DESIGN Date 2022.02.08 Project Name Dartmouth Apartments Project Number 1903007 Attention Company Essex General Construction Inc Address 4284 W 7th Avenue Eugene, Oregon, 97402 Phone (503) 747-0092 Email Submittal Name Acoustical Ceilings Submittal No, 09 51 00— 1.0 Revision The following comments refer to the submittal listed above. They supplement all comments made within the submittal itself and do not necessarily represent all comments within this submittal. General Comments: 1. No Exceptions Sender Charlie Baxter SUBMITTAL REVIEW V NO EXCEPTIONS NOTED E DISAPPROVED cc ❑ NO EXCEPTIONS NOTED IN CORRECTED COPY ri REVISE AND RESUBMIT C NOT REVIEWED Reviewed only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. This review does not affect the Contractor's responsibility to perform all contract requirements with no change in contract price or time. Any actions shown are subject to the requirements of the Contract Documents. Contractor is responsible to confirm and correlate dimensions at the site for information that pertains solely to the fabrication processes for the means, methods, techniques, procedures, sequences, and quantities necessary to complete the contract and for coordination of the work of all trades and the satisfactory performance of his work. Any review is undertaken solely to satisfy Architects obligations, if any, to the Owner and shall not give rise to claim by Contractor or other parties against Architect or Owner. Artur Grochowski REVIEWED BY SERA 2/8/2022 DATE 338 NW 5TH AVENUE PORTLAND OR 97209 T 503.445.7372 F 503.445.7395 SERADESIGN.COM -� --4- Submittal Review Essex 72nd & Dartmouth • GENERAL CONSTRUCTION,INC. Section: 095100-1.0 Date: 01/28/22 Subcontractor/Supplier: Westside Drywall Description: Acoustical Ceilings Contractor: Stamp See Table of Contents on Page 2 Essex General Construction Inc This drawing or submittal has been reviewed for general conformance with plans and specifications.Review does not relieve fabricator/vendor or subcontractor of responsibility for errors,omissions,or non-compliance with contract documents. x_fre;‘,1 01/26/2022 Reviewed Eliot Adams Architect: Sta m p Engineer/Consultant: Stamp 4284 W 7th Avenue.Eugene,OR 97402 I 541-342-4509 www.essexgc.com 17400 SW 65`h Avenue.Lake Oswego,OR 97035 1503-747-0092 CC8#OR 54531 WA ESSEXGC852JC - 14 Essex GENERAL CONSTRUCTION,INC. Section: 095100-1.0 Date: 01/28/21 Subcontractor/Supplier: Westside Drywall Description: Acoustical Ceilings Table of Contents I. ACT-1: ULTIMA 9/16" Beveled Tegular, 30"x30",White 3 a. Product Data 3 b. Installation Instructions 7 c. Grid: Interlude 9/16" Product Data 16 d. Shop Drawings 20 II. ACT-2: Lyra PB Concealed 15/16",24"x72", Filz Felt Olive 27 a. Product Data 27 b. Installation Instructions 29 c. Trim:Axiom Product Data 39 d. Grid: Prelude XL 15/16" Product Data 43 e. Shop Drawings 47 Ill. Engineering: ESR-1308 53 4284 W 7th Avenue.Eugene,OR 97402 I 541-342-4509 www.essexgc.com 17400 SW 65th Avenue.Lake Oswego,OR 97035 1503-747-0092 CCBM OR 54531 I WA ESSEXGC852JC ULTIMA° (6) "..,,< ULTIMA® High NRC V TOTAL SUSTAIN` 24/7 Tegular ACOUSTICS- High Peformance DEFEND" Sound Absorption(NRC) Sustainable Sdufrons for Healthier, fine texture +Sound Blocking (CAC) Ceiling Systems Safer Spaces CONTAIN PROTECT CAD/Revitc,' drawings at: armstrongceilings.eom/cadrevit iC] }t -Fhb . d .+'�` ' u 7 �y,' # �� DESIGNFIex' ,"' L �� . - z t tz d x p a s. 2, fi. A New World of Choice Y � ,,,s .� a 3'i 5 '1 ' for Ceiling Systems -i is`" _'TT v �';3' fin.- _'t', S' +; :R, i a 4 ,� -� d § *£ 5 aksz s*4 _, 1. a a 'a lus capabilities 4 xi za ,s-.r t� ,� tr'''''' --It' ''''- armstrongceilings.com/capabilities i A Ultima®Beveled Tegular panels with Suprafine®9/16"suspension system See more photos at: armstrongceilings.com/photogallery Smooth-texture panels that are washable,impact-and scratch-resistant with a non-directional visual. Offer both Sustain®and Total Acoustics®panel performance for flexible spaces. KEY SELECTION ATTRIBUTES TYPICAL APPLICATIONS • DESIGNFIex'"options include shapes • CleanAssure'"family of products • Item 1912 available with Create!'" • Offices—closed spaces for privacy and made-to-order sizes available to ship includes disinfectable panels, printed images and patterns and confidentiality;open spaces in 3 weeks suspension systems,and trim • Non directional visual reduces scrap for focus,collaboration,and and installation time teaming • Get total noise control and floor plan Mold-and mildew-resistant surface versatility with Total Acoustics®ceiling panels: • Smooth,clean,durable finish— Compatible with the TechZone Healthcare—assists in addressing NRC+CAC=Total Acoustics performance Washable,Impact-resistant, Ceiling Systems HIPAA,HCAHPS,and FGI • Ultima®panels are part of the Sustain® Scratch resistant,Soil-resistant • 30-Year Limited System Warranty acoustical requirements portfolio,and meet the most stringent • Ceiling-2-Ceiling'"Post-consumer against visible sag(excludes items • classrooms sustainability compliance standards today Recycled Content options:items 1911 1905 and 1929),mold,and mildew • Corridors HRC,1912HRC,1914HRC,1915HRC. • 10-Year replacement • Lobbies/reception areas 71%Pre-consumer; panel available for 1O-YEAR Department stores/retail COLOR 15%Post-consumer items 1911,1912, REPrACe ntlt! • • USDA-Certified Biobased 1914,1915 Product—95% • Available with factory-cut holes for USAF • Available with AirGuard'coating trimless downlight fixture integration. White (WH) DETAILS (Other Suspension Systems compatible.Refer to listing on next page.) 1.Ultima®Beveled Tegular \\,,,,, r-.' \,\ 2.Ultima®with Suprafine®9/16"suspension system iiiiii 3.Ultima®with Silhouette®XL®9/16"suspension system with 1/4"reveal TechLine 877 276-7876 ®rmstrong CEILING&WALL SOLUTIONS armstrongceilings.com/ultima RECYCLED ; c . m !- Calculate sustainabi(d1 with OreenGenie" ULTIMA® �� of 0 CONTENT ' armstrongceilingscomlgreengenie ULTIMA® High NRC CERTIFIED O D SUeTAanc J_t 0 Gt'i t' 01 ti 10 t'10; 0 ?0 0!0 PRODUCT High Performance -J CLOSED mmrxrasx Sustainable Ceiling Systems u.i E rn a n Tegular LOOP �° =d �E d oC o s o 0E a E" L a h w fine texture CEILIF;'2 Declare. (details betow) 88 E u'' m E as w 0.m a a E 0 o y? E 0. o f ='B m LOCATION DEPENDENT VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. His- Humi- CleanAssure'" DURABILITY E Block Guard+ •3 cq Disinfectable Panels 0cii C C = J 13 E. R _ d gjtj @ € & N 9. L d UL Classified bl sii c�a e o S .-g i ,5 1 n r Acoustics �8 R a ¢sE .`!Z r73 uR E 3 E Si r9 a g amistrongceilings. Sus . Dimensions _ NRC /�+� '. .� NRC com/catdwgs (Mg Item No. (Inches) .r - cr® ®0 V rib O v) IN ® tt CAC ULTIMA®High NRC 15 1941 24 x 24 x 7/8" ❑ 0.80 35 BEST 170 Class 0.88 • • • ' AC 15/16" • (Of)) • A • v Beveled Tegular 1944 24 x 48 x 7/8" I I 0.80 35 BEST 170 Class 0.88 • • • 1433 24 x 60 x 7/8" I I 0.80 35 BEST 170 Class 0.88 • • • t HRC items not aWJ� 4 A ' Included in made-to-order 1438 24 x 72 x 7/B'1 I 0.80 35 BEST 170 Class 0.88 • • • • • • panels. • l(i0 A - ULTIMA®High NRC 29,44, 1942 24x24x7/8'0 0.80 35 BEST 170 Class 0.88 • • 9/16" 58,52, - • a')) • A 1 Beveled Tegular 1942HRC 24 x 24 x 3/4"❑ 0.75 35 BEST 170 Class 0.88 • • • • • • 1 • • rO • A • 1945 24 x 48 x 7/8" I I 0.80 35 BEST 170 Class 0.88 • • • • Oil HRC items not • ((ii) • A • �Cd included in --------------- -- - -- made-to-order 1431 30 x 30 x 7/8" 0.80 35 BEST 170 Class 0.88 • • • • • panels. • • i(;;) • A t4 1434 24 x 60 x 7/8° I I 0.80 35 BEST 170 Class 0.88 • • • • • • P i . A " 1437 24 x 72 x 7/8" I J 0.80 35 BEST�,���� 170 Class 0.88 • • • `1J „n • • ) • A " 7/8"Thick-15/16"&9/16"Beveled Tegular �J e Made-to-Order 1 Ctn Min Width Length WA WA WA WA Clan 0.88 • • • Sizes ASTSIZ 4^-6" 12'-72" A • t) Visit the product page 3 WEEKS 6-1/2"-30" 4'-72" online and see"Configure order to ship 30-1/2"-48" 4'-30" an tern'to verify capabilities. Questions?email Techllnemarmet®npceW s.Cem MORE ITEMS► (All 1 Total Acoustics®ceiling panels have an ideal combination of sound absorption and sound blocking in one product. Oa GOOD(NRC 0.60-0.65;CAC 35+) BETTER(NRC 0.70-0.75;CAC 35+) BEST(NRC 0.80+;CAC 35+) ♦ 11 SUSPENSION SYSTEMS 15/16" , 9/16" (-1'r Blizzardolo White ou Suspension System Finish j J 7L� A color and texture coordinated suspension Prelude® Silhouette® Silhouette Suprafine® Interlude®XL®HOC system to complement Ultima®ceiling panels 1/4"Reveal 1/8"Reveal for a monolithic look and feel. PHYSICAL DATA r Material VOC Emissions PRODUCT CEaTIFIEO ,, Cleaning and Disinfecting Wet-formed mineral fiber with DuraBrite® GREENGUARD Gold Certified FOR LOW CHEMICAL Cleaning and CDC recommended disinfecting options Pal EMISSIONS acoustically transparent membrane Third-party certified compliant Ix.COM/GG available on armstrongceilings.com/cleaning �� Surface Finish with Cardornia Department of Public UL 2818 30-Year Performance Guarantee&Warranty DuraBrite scrim with factory-applied latex paint Health CDPH/EHLB/Standard Method GREENGUARD When installed with Armstrong®Suspension System. Version 1.2,2017.This standard Is the Details at armstrongceilings.com/warranty Fire Performance guideline for low emissions in LEED®,WELL corn Class A:ASTM E84 and CAN/ULC S102 surface Building Standard'",Living Building Challenge® J Weight;Square Feet/Carton mai burning characteristics.Flame Spread Index of 25 or (LBC),CalGreen Title 24,ANSI/ASHRAE/USGBC/IES 1945-1.14 lbs/SF;48 SF/ctn less.Smoke Developed Index of 50 or less(UL labeled). Standard 189;ANSI/G81 Green Building Assessment Protocol. 1941,1942,1942HRC-1.125 lbs/SF;40 SF/ctn ina SF/ctn Fire Guard'":A fire-resistive ceilingwhen used Acoustical Performance 1433-1.125 lbs/SF; 48 F/ctn in applicable UL assemblies(Clas A) CAC testing conducted using Prelude®XL®suspension system 1436-1.05 60 SF/ctn for 15/16"edge detail and Silhouette®suspension system for 14316-1.04 lbs/SF 72 5 SFtn ASTM Et 264 Classification 9/16°edge detail. p y 1431-1.06 lbs/SF 62.5 SF/ctn Type IV,Form 2,Pattern E 91434-1.05 lbs/SF 60 SF/ctn Fire Class A Primary(Embodied)Energy 1437-1.04 lbs/SF,72 SF/ctn A Humidity/Sag Resistance See all LCA information on our EPDs. Minimum Order Quantity ams HumiGuard®Plus ceiling panels are recommended High Recycled Content 1 carton Ao for areas subject to high humidity,up to,but not Contains greater than 50%total recycled content. Metric Items Available A Including,standing water and outdoor applications. Total recycled content based on product composition of 1941M,1944M,1945M-Metric items are iso Anti-Mold/Mildew post-consumer and pre-consumer(post-Industrial)recycled subject to extended lead times and minimum Ceiling panels with BioBlock®performance resist the content per FTC guidelines.HRC items contain 15%or quantities.Contact your representative for growth of mold and mildew on the tile surface. greater post-consumer recycled ceilings. more details. Insulation Value R Factor-2.2(BTU units);R Factor-0.39(Watts units) TechLine 877 276-7876 &mstrong® armstrongceilings.com/ultima CEILING&WALL SOLUTIONS RECYCLED ULTIMA® USDA • m i O Calculate sustainability with GreenGenie'" CI--IO CONTENT armstrongceilings.coin/greengenie CERTIflED W ULTIMA® High NRC Bl° D SUSTAIN' t'i 0 ,0 ti 0 �' 1010 c't'i01 PRODUCT High Performance -I 1 , CLOSED FRooucrssx Sustainable Ceiling Systems L LI 5 o E E la $= Tegular RECYCLED E S.E. _ E� €f.Z.! u 1 aREENGUARD ` fine texture CONTENT Declare. Gold Certified e,E S 3 d E a a.a E 5 H 19•E =Q to • LOCAmON DEPENDENT VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. $$ Bin- Humi- CleanAssure- DURABILITY m C� - Block Guard+ 3`a Disinfectable Panels ID 11) a € ¢ -3 .=`O. lift- u w UL Classed ' m L -v y F U a E I _ c�i Acoustics �; ¢` dr v3 s c°3 i cA c2 , NRC armstron ceilin s. Dimensions Nnc <- e e Susp. + = CAC co V rl' �.r CAC camlcatdwgs Dwg. Rein No. (Inches) t ULTIMA® 15 1422 6 x 48 x 3/4" ® WA WA WA Class 0.88 • • • 15/16" A Beveled Tegular 1917 12 x 24 x 3/4"o N/A N/A WA Class 0.88 • A ii HOC items not 1993 12 x 48 x 3/4"0 0.65* N/A WA Class 0.88 • included in A di made-to-order 6 panels. 1994 12 x 60 x 3/4"0 0.65* N/A N/A Class 0.88 • • , A • 1995 12 x 72 x 3/4" l ' 0.65* N/A WA Class 0.88 • • • • • . p� A • *CS 1911 24 x 24 x 3/4"❑ 0.75 35 BETTER(lass 0.88 1911 HRC 24 x 24 x 3/4" • • (0) A • IV 1951 24 x 24 x 3/4"❑ 0.60 40 GOOD Class 0.88 • • • • • • G)) A • 1894 24 x 24 x 3/4" ❑ 0.60 40 GOOD Flre 0.88 • • . t Guard'" • 1914 24 x 48 x 3/4"I= 0..5 35 BETTER Class 0.88 • • 1914HRC 24 x 48 x 3/4" l($,) A t) 1985 24 x 60 x 3/4"I I 0.75 35 BETTER Class 0.88 • • • ,(h) A • ril 1981 24 x 72 x 3/4"I I 0.75 35 BETTER Class 0,88 A n . 9/16" 29.44, 1423 6 x 48 x 3/4" ® WA WA WA Class 0.88 • Beveled Tegular 48,52, A 56 1427 6 x 60 x 3/4" WA WA N/A Class 0.88 A HRC items not included in 1916 12 x 24 x 3/4"I=I WA WA N/A Class 0.88 • • • made-to-order A , panels. 1996 12 x 48 x 3/4" 1=1 0.65* N/A N/A Class 0.88 • • A 1997 12 x 60 x 3/4" I I 0.65* N/A N/A Class 0.88 • A , • • 1998 12 x 72 x 3/4" r , 0.65* N/A WA Class 0.88 • • • • A • 1912 24 x 24 x 3/4" ❑ 0.75 35 BETTER Class 0.88 • • all• if!y 1912HRC 24 x 24 x 3/4" • • «/ A am. 1952 24 x 24 x 3/4" ❑ 0.60 40 GOOD Class 0.88 • • • • ui) A • �' • 1895 24 x 24 x 3/4" ❑ 0.60 40 GOOD Fire 0.88 " •� `)))) Guard • I 1915 24 x 48 x 3/4" I I 0.75 35 BETTER Class 0.88 • tip 1915HRC 24 x 48 x 3/4" )))) A • 1 Total Acoustics•ceiling panels have an ideal combination of sound absorption and sound blocking in one product. GOOD(NRC 0.60-0.65;CAC 35+) BETTER(NRC 0.70-0.75;CAC 35+) BEST(NRC 0.80+;CAC 35+) *Item not UL tested TechLine 877 276-7876 ®rmstrong® armstrongceilings.com/ultima CEILING&WALL SOLUTIONS - c' RECYCLED m Calculate sustamabilitywith GreenGenie'" ULTIMA° usi 0 CONTENT armstrongceiiings.com/greengenie CERTIRED ULTIMA® High NRC P OBASED SUSTAIN W ti Cif�'iG O. 01t'i t'i!i'i G ci rink PRODUCT High Performance —1 e. le i• e i eceoaCTsa% Sustainable Ceding Systems LU V, o f F. a 'g, Tegutar Li m m«' COO in' . �mg W gE r�r E, �Ti `�" fine texture r ti3.2,e.;.O Declare. (details below) m E s 3 d E vc w IilliR a E ?o sin.. PST. o f Pig Q m 1 LOCATION DEPENDENT ° VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. S$ Bio Humi- CleanPssure'" DURABILITY m Block Guard+ 3 c Disinfectable Panels c N C _ J. C f` UL Classified g o d , — o,w f cs E o } Acoustics r� L= d` act cf g LF 3 A v3 1 12 g armstron ceilin s. Sus Dimensions NRC CO com/catdwgs Dwg. item No. (Inches) +G. cnc © � fAg` ® Q NCAAC ULTIMA® 29,44, 1986 24 x 60 x 3/4" I I 0.75 35 BETTER Class 0.88 9/16' 48,52, (fit) A AC 56 Beveled Tegular 1982 24 x 72 x 3/4"I I 0.75 35 BETTER Class 0.88 • • • • (('I)) A ° A 1905 30 x 30 x 3/4"I❑ 0.75 35 BETTER Class 0.88 • Std • 1-Yr HRC items not 19USHHC 30 x St.)x 3/4" • • (ji)) A • t Included in made-to-order 1929 30 x 54 x 3/4" I I 0.75 35 BETTER Class 0.88 • Std • 1-Yr panels. 0 1929HRC 30 x 54 x 3/4" • • ')) A • 3/4"Thick—15/16"&9/16"Beveled Tegular Made-to-Order 1 Ctn Min Width Length N/A N/A N/A Class 0.88 a 4 Sizes ASTSIZ=_ 4"—6" 12"—72" A visit me product page 3 WEEKS 6-1/2"—30" 4"—72" lir online and see"Configure order to ship 30-1/2"—48" 4"—30" an hem"to verity capabilities. • Questions?email Techline®armstrongceilings,com 4111, ULTIMA® 15 11 1901 24 x 24 x 3/4"❑ 0.75 35 BETTER Class 0.88 • with AirGuard"Coating 4 A • "15/16" ` Beveled Tegular ,1% 1904 24 x 48 x 3/4"El 0.75 35 BETTER Class 0.88 • • • I 9/16" 29, : i 1902 24 x 24 x 3/4" ❑ 0.75 35 BETTER,,,�T� Class 0.88 • • • Beveled Tegular 48,52, (i )) A ° C' Ll l 56 1906 24 x 48 x 3/4"I J 0.75 35 BETTER Class 0.88 • �� AirGuare Coating actively �) removes formaldehyde from indoor air. t Total Acoustics®ceiling panels have an deal combination of sound absorption and sound blocking In one product. GOOD(NRC 0.60-0.65;CAC 35+) BETTER(NRC 0.70-0.75;CAC 35+) BEST(NRC 0.80+;CAC 35+) 1�� SUSPENSION SYSTEMS 15/18" (-- j�� 9/16" Blizzardol to—Suspension System s Finish �_—a A color and texture coordinated suspension Prelude• Silhouette® silhouette Supratine" Interlude"XL.HRC system to complement Ultma®ceiling panels 1/4"Reveal 1/B"Reveal for a monolithic look and feel. PHYSICAL DATA VOC Emissions PRODUCT CERTIFIED / 'N 30-Year Performance Guarantee&Warranty GREENGUARD Gold Certified FOR LOW CHEMICAL When installed with Armstrong®Suspension System. Material Third-party certified compliant �csu/se Details at armstrongceilings.com/warranty Wet-formed mineral fiber with DuraBrite® with California Department of Public el Me Weight;Square Feet/Carton acoustically transparent membrane Health CDPH/EHLB/Standard Method 1917,1993—1.05 lbs/SF;24 SF/ctn Version 1.2,2017.This standard is the GREENGUARD Surface Finish 1422—1.08 lbs/SF;24 SF/ctn ■• DuraBrite with factory-applied latex paint guideline for low emissions in LEED®,WELL ® cold 1905,1905HRC—1.05 lbs/SF;62.5 SF/ctn Building Standard'",Living Building Challenge l S► Fire Performance (LBC),CalGreen Title 24,ANSI/ASHRAEAISGBC/IES 1.051 a/SFH 48 F/ctn1912 1912HRC,1914,1914HRC,1915— Class A:ASTM E84 and CAN/ULC S102 surface Standard 189;ANSI/GBI Green Building Assessment Protocol. 91lbs/SF; 1.05 lb 1916,1996—1.05 lbs/SF;24 SF/ctn burning characteristics.Flame Spread Index of 25 or Acoustical Performance 1423—1.08 lbs/SF;24 SF/ctn less.Smoke Developed Index of 50 or less(UL labeled). CAC testing conducted using Preludes XL®suspension system 1427—1.07 lbs/SF;24 SF/ctn aso Fire Guard':A fire-resistive ceiling when used for 15/16"edge detail and Silhouette®suspension system for 1929,1929HRC—1.02 lbs/SF;68 SF/ctn in applicable UL assemblies 9/16"edge detail. 1895,1952,1951—1.31 lbs/SF;48 SF/ctn WS ASTM E1264 Classification Primary(Embodied)Energy 1901,1902,1904,1906—1.08 lbs/SF; Type IV,Form 2,Pattern E;Fire Class A See all LCA Information on our EPDs. 48 SF/ctn Humidity/Say Resistance High Recycled Content 1997,1994—1.05 lbs/SF;30 SF/ctn HumiGuard®Plus ceiling panels are recommended Contains greater than 50%total recycled content.Total recycled 1981,1982—11.08 lbs/SF;lbs/SF;726F/ct SF/ctn for areas subject to high humidity,up to,but not content based on product composition of post-consumer and 1894,1985-986 SF 80n Including,standing water and outdoor applications. pre-consumer(post-industrial)recycled content per FTC guidelines. 1894,1985,1986—1.08 lbs/SF; SF/ctn (Excludes items 1905 and 1929). HRC items contain 15%or greater post-consumer recycled ceilings. Minimum Order Quantity mu i. Anti-Mold/Mildew Insulation Value 1 carton Ceilingpanels with BioBlock®performance R Factor—2.2 BTU units);R Factor—0.39 Metric Items Available ( ) (Watts units) 1905M,1912M,1912MHRC,1914M,1915M, SI resist the growth of mold and mildew on the tile surface. Cleaning and Disinfecting 1916M—Metric items are subject to extended Cleaning and CDC recommended disinfecting options lead times and minimum quantities.Contact available on armstrongceilings.com/cleaning your representative for more details. TechLine/1 877 276-7876 LEIN N a registered trademark of the U.S.Green Building Council;Declare"and Living Building Challenge"(LBC)are hatlemarks ( mstrong• armstrongceilings.com/ultima of the International Living Future Institute•;WELL'and Wen Building Standard are trademarks of the International WELL Building Institute;UL and UL Certified are registered trademarks of UL LLC;USN Lighting is a trademark of USA!Lighting,LLC; BPCS-3039-1020 all other trademarks used herein are the property of AM Licensing LLC and/or its affiliates 0 2020 AWI Licensing LLC CEILING&WALL SOLUTIONS INTERLUDE® XL® High Recycled Content SUSTAIN- 24/7 High Performance DEFEND" Sustainable Solutions for Healthier, 9/16" Dimensional Tee Suspension System Ceiling Systems Safer Spaces CONTAIN PROTECT This dimensional 9/16"suspension system offer high-recycled content for improved LEED®credits. KEY SELECTION ATTRIBUTES f "' f • Seismic Re Suspension System saves •Accommodates virtually any fixture, r time and money;offer an ICC-ES especially 1'x 4'light fixtures and air approach handling i. to installations(ESR-1308) • 10-Year Limited System Warranty; • Hot-dipped galvanized coating inhibits 30-Year Limited Ceiling Systems a ± red rust better than electrogalvanized Warranty when used with or painted systems HumiGuard®Plus products • ' • Interlude®XL®is part of the Sustain" • Some items available in metric sizes — /E d portfolio and meets the most stringent • Made-to-order main beams and cross _ I, •t industry sustainability compliance tees can be ordered with special sizing 4 ---""" .—... ' 11, standards today and rout spacing for your project needs " el• CleanAssure'family of products- in one carton minimum • >, includes disinfectable panels,suspension • Continuous rolled single piece system systems,and trim(Cleaning and CDC • Blizzard White powder-coated finish sP approved disinfecting options available dlib „ on armstrongceilings.com/cleaning) coordinates with Calla ,Optima , •. .„ Ultimo ,and Lyra ceiling panels K'` ' • Rotary-stitched during manufacture for a clean,seamless,monolithic Or -,,,,,, for additional torsional strength and installed visual extra stability during installation • Linear lighting integration is easy a • XL®staked-on end detail provides ' secure locked connection with made-to-order main-beam-to- ` cross-tee adapters,rout spacing, " i n . • Unmitered intersections for flexibilityof �k • miter spacing,and short cross cross tee placement tees(3"to 6"lengths) Interlude®XL®suspension system • 10-Year replacement 10-YEAR REPLENT items available AVAILABILITY COLORS AND FINISHES Due to printing limitations,shade may vary from actual product. Standardill i. f44os Powder Coated Finishes a ,,C.....e_517i'f.1, ‘..„. r. rzo , ,-,z4 ._,,, ,......./...,.-, cle...) Itjr�tl>/ NOTE Powder-coated finishes are also available on select White Tech Black Light Grey Grey Stone Stone Mist Sandstone Custom Colors Blizzard Charcoal Mama Classic,Knife Edge®, (WH) (BL) (LG) (GS) (SE) (SMT) (SSS) Available' White(ZN6 Black(ZB) and Vector•trim profiles Fossil Feldspar Boxwood Lilac Rainstorm Oat (SFL) (SFS) (SBW) (SLC) (SRS) (SOT) 'Colors that are pre-qualified to meet Sustain"portfolio requirements are available upon request. ei Other made-to-order colors must be evaluated 6 sustainability criteria is required.Lead time will increase. NOTE 360 paint finishes and custom colors available as special order. s me VISUAL SELECTION PERFORMANCE PACKAGING . l HANGER SPACING* CleanAssuro- LBS./LFT 1 o,4 Disinfectable Grid --.. Rout Dimensions `� ^ 1 t- Item No.* Description Spacing (Inches) 1 Ft. 2 Ft. 4 Ft. 5 Ft. a a c3 7 , INTERLUDES XL® 6100HRC__0 12'ID Main Beam 6"0.C. 144 x 9/16 x 1-3/4" WA N/A 12.6 N/A WA WA • • • 20 240 9/16" 6101 HRC 12'HD Main Beam 6"O.C. 144 x 9/16 x 1-3/4" WA WA 16.79 WA N/A • • • • 20 240 • - 610010HRC__- 9/16"10'Main Beam 6"O.C. 120 x 9/16 x 1-3/4" WA WA 12.6 WA WA N/A ,• • • 20 200 • XL6180NRC_ 4• 8'Cross Tee 12"O.C. 96 x 9/16 x 1-3/4" N/A WA 12.6 N/A N/A • • 20 160 Made-to-Order main beams and cross tees can be ordered with special sizes,rout spacing,and colors for your project needs In one carton minimums. Dots represent high ASTM Claw *Simple Span level of performance. H fD- memeailY ate-duty •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the Item number(e.g.6101 HRC L 0_-Light Grey) Ln- Light-duty •b Available in White(WI-6,and Blizzard White and Charcoal Black powder-coated finishes only TechLine 877 276-7876 ( mstrong° armstrongceilings.com/interlude CEILING&WALL SOLUTIONS o RECYCLED m 0 Calculate sustainabiity with GreenGenie" b J a CONTENT ! armstrongceilings.com/greengenie w ._ INTERLUDE® XL® w_. .000.0, C c SUSTAIN' J WcE 1 m I,,.-m High Recycled Content High e Cesingy +�. IL a T ,. m$2. — _ Sustainable CeYing SysYrs �• .,a, ' c i 1...''me a c I c E c c E a oiA m ac 1 9/16" Dimensional Tee Suspension System Declare-. m E 133 E sal ,m E..1 E ge.ligg2.3 E :a LOCATION DEPENDENT VISUAL SELECTION PERFORMANCE PACKAGING $NISPASPA INB" CleanXssure" LASAFT ,.,o Disinfectable Grid E F, A c rn 8 S N 'i I Rout Dimensions li Item No.• Description Spacing (Inches) 1 Ft. 2 R. 4 R 5 Ftt!g i INTERLUDE®XL® XL6190HRC_ 6'Cross Tee 12"0.C. 72 x 9/16 x 1-3/4" WA WA 12.6 N/A N/A • • • • 20 120 t Iii 9/16" DEF XL6150AHRC__+ 5'Cross Tee 6",20", 60 x 9/16 x 1-3/4" WA N/A N/A 5.8 N/A • • • • 60 300 30"O.C. XL6140HRC___ 4'Cross Tee 12"O.C. 48 x 9/16 x 1-3/4" 3.0 WA 12.6 WA N/A • • • • 60 240 f` XL617OHRC -- 2.5'Cross Tee N/A 30 x 9/16 x 1-3/4" 38.8 N/A WA WA WA • • • • . 80 100 410 XL6120HRC___ 2'Cross Tee N/A 24 x 9/16 x 1-3/4" WA 66.89 N/A N/A WA • • • • 60 120 4 .:7 61.6118H _ 1'Cross Tee N/A 12 x 9/16 x 1-3/4" 66.89 WA N/A WA WA • • • • 120 120 1 CM Min 9/16"Interlude*XI! Size Capabilities ASTSIZ: Main Beams Cross Tees N/A N/A N/A N/A WA N/A WA • • • Varies Varies NOTE:Up to 6 weeks 2 WEEKS Length Length for color and size order to ship -. combinations. 48"-144" 3"- 144" Rout spacing 3"from ends, 6"thereafter Made-to-Order main beams and cross tees can be ordered with special sizes,rout spacing,and colors for your project needs In one carton minimums. Dots represent high ASTM cress *Simple Span level of performance. HD- Heavy-duty ID- Intermediate-duty •When specifying or ordering Items with a color or finish,add the two-or three-letter suffix to the end of the Item number(e.g.XL6140HRC L 6._—Light Grey) LD- Light-duty Available in White(WH),and Blizzard White and Charcoal Black powder-coated finishes only VISUAL SELECTION PERFORMANCE PACKAGING HANGER SPACING* T CleanAssure'" LBS.A.FT d c,3 Disinfectable Grid a 2 •, Qe co q�q9 'po e63' S I p RoutDimensions Q i r Item No.* Description Spacing (Inches) Ftc 2 4 Ft. 5 Ft. Div ttt��� ------- --INTERLUDE XL 6195AHRC__,% 126"HD Main Beam 10",30", 126 x 9/16 x 1-3/4' WA 16.79 N/A WA • • • • 20 210 el HRC items 50",70", forTechZone® 90',110 Ceiling Systems 116 — — — — - 6127AHRC__i' 120"HD Main Beam 15",42", 126 x 9/16 x 1-3/4" N/A 16.79 N/A WA • • • • 20 200 ID 9/16" 48",75", 102",108" XL6164AHRC__w 54"Cross Tee 6",27", 54 x 9/16 x 1-3/4" WA 92 et 4.5' N/A WA • • • • 60 270 48" XL6162HRC__•:• 42"Cross Tee N/A 42 x 9/16 x 1-3/4" WA 20 at 3.5' N/A WA • • • • 60 210 XL6167HRC_ 0 27"Cross Tee N/A 27 x 9/16 x 1-3/4 49.32 WA WA N/A • • • • 60 135 - XL6106HRC • 6"Cross Tee N/A 6 x 9/16 x 1-3/4" N/A WA WA WA • • • • 60 30 • XL6104HRC__O 4"Cross Tee N/A 4 a 9/16 x 1-3/4" N/A N/A WA WA • • • • 60 20 me so — e. NOTE:Additional Interlude XL items for TechZone•Ceiling Systems are listed in the TechZone Technical Guide(BPCS-4486). Dots represent high ND TM Casety Available online at armstrongceilings.com/techzone level of performance. ID- eavy-y-dudty duty la at•When specifying or ordering items with a color or finish,add the two-letter suffix to the end of the item number(e.g.6195AHRC Z W—Blizzard White) LD- Light-duty fe Available In White(WH),and Bliaard White and Charcoal Black powder-coated finishes only Iii TechLine 877 276-7876 ®rmstrong• armstrongceilings.com/interlude CEILING&WALL SOLUTIONS Q RECYCLED •® �p a Calculate sustainability with GreenGenie"" c —1 % O CONTENT armstrongceilings.com/greengenie INTERLUDE® XL® i'i G 001 '�iC' SUSTAIN' W m o i c High Performance E E `—ry o High Recycled Content Sustainable CeiMgSystems Pa E oai i mom �� m E 9/16" Dimensional Tee Suspension System Declare: G • G 'm 6,a 3 E 9 L ypy-e�p"r E c,3 E ac w a E m`6 E °.' _E a' LOCATION DEPENDENT " VISUAL SELECTION PERFORMANCE PACKAGING HANGER SPACING* CleanAssure'" LBS./LFT Disinfectable Grid T ii Rout Dimensions �' c Item No.* Description Spacing (Inches) 4 Ft. 5 Ft. 444 SUPRAFINE XL 360° AX75003___ 12'ID Main Beam, N/A 144 x 9/16 x 1-11/16" 12.75. 5.74 N/A WA • • • 20 240 Painted Grid to match Routs 6"O.C. Axiom®Trim AX75013 __ 12'ID Main Beam, N/A 144 x 9/16 x 1-11/16" 16.86 10.62 WA N/A • • • 20 240 DE F Routs 6"O.C. 9/16" AX75103___ 1'Cross Tee WA 12 x 9/16 x 1-11/16" 51.83 N/A N/A N/A • • • • 120 120 AX75203___ 2'Cross Tee N/A 24 x 9/16 x 1-11/16" 51.83 N/A N/A N/A • • • 60 120 ,e: AX75703___ 30"Cross Tee N/A 30 x 9/16 x 1-11/16" 28.67 N/A N/A WA • • • 60 150 AX75403___ 4'Cross Tee N/A 48 x 9/16 x 1-11/16" 10.34 N/A N/A WA • • • 50 240 'e AX75553___ 5'Cross Tee 6",20",and 30" 60 x 9/16 x 1-11/16" N/A 5.80 N/A WA • • • 60 300 from ends *Simple Span Dots represent high AM crass •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the item number(e.g.Ax75003 L 6_-Light Grey) level of performance. ND- Heavy-duty ID- Interrtredate-duty e. 4.Items available in Blizzard White and Charcoal Black powder-coated finishes only iD- Light-duty JO ♦;:• VISUAL SELECTION PACKAGING ac (A) (B) (C) a_,-2u_ Item No.* Description Length Flange Flange Reveal a� Suggested Wall Moldings 7800HRC__6, 12'Hemmed Angle Molding 144" 7/8" 7/8" N/A 30 360 and Shadow Moldings 7804HRC__+ 12'Hemmed Angle Molding 144" 9/16" 7/8" N/A 30 300 (Additional moldingoptions available) 7873_ + 10'Shadow Molding 120" 9/16" 15/16" 3/8" 30 360 7874__++ 10'Shadow Molding 120" 9/16" 15/16" 1/4" 30 300 7877__+" 10'Seismic Shadow Molding 120" 15/16" 15/16" 1/4" 30 300 7878___" 10'Seismic Shadow Molding 120 15/16" 15/16" 3/8" 30 300 **Suitable for IBC Category D,E,F installations using Armstrong°Seismic Rx•suspension system and BERC2 Clip •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the item number(e.g.7878 L Sa_-Light Grey) 4•Available in White Will,and Blizzard White and Charcoal Black powder-coated finishes only sw 4. all MAXIMUM FIXTURE WEIGHT Drawing Key:Main beam(I) Cross tee(-)Hanger wire(+) i Configuration Item Fixture Planning Module Hanger Spacing Maximum Weight A B No. A B A B A B A B Main Beam to -' 6100HRC 24"x 48" N/A 48"x 48" N/A 48" WA 75.0 lbs. N/A Main Beam .----- i 1- L ----- — ----- Main Beams tested as follows:6100 tested et 12.6 BsAF to 1/360 of 4'span. Cross Tee to EH XL6140HRC I 24'x 46" 24'x 24' 48"x 45" I 48"x 48" 48" 48" 75.0 lbs. 75.0 lbs. Cross Tee ?-17:1 I MD Cross tees tested as follows:)L6140 tested at 12.6 Ibs.yLF to 1/360 of 4'span. - Fixtures weighing more than 56 lbs.should be independently supported.Fixture weight is based on single future only.For end-to-end Mures or other configurations not shown,consult your Armstrong Ceilings representative. NOTE:The above data is based on 48"hanger wire spacing,board weight of 1 lb./SF,maximum deflector of tees not to exceed 1/360 of the span,and suspension system installed in accordance with ASTM C636. a TechLine 877 276-7876 mstrong° armstrongceilings.com/interlude CEILING&WALL SOLUTIONS c3) " RECYCLED !: m a Calculate sustainabilay with GreenGenie-" o0 CONTENT I armstrongceilings.comtgreengenie INTERLUDE® XL® - J G G G G, G G SUSTAIN' LL ` of R 'o, High Recycled Content Nigh Performance _ cz,. • _ d _ N Sustainable,form Systems y, m,8 m ,'�, c" °, cc:,E 'dam c Em.E a 9/16" Dimensional Tee Suspension System Declare. =N B.N .m E a 11-' E d E H B E m E LOCATION DEPENDENT ACCESSORIES • gg t Item No. Description s c"j Item No. Description s c`3 BERC2 2"Beam End Retaining Clip IES3 Interlude Expansion Sleeve Allows you to create a code compliant Seismic ° ° ``\ 4' 1,I D,E,F ceiling installation while eliminating the I `� P need to use 2"wall molding or spreader bars. DE 54,3• <,.;7 BERC2 Steel 200 FZBERC2 Steel 50l,e . IES3 200 ALBERC2 Aluminum 200 FZIES3 50 FZALBERC2 Aluminum 50 GCWA Grip Clip Wall Attachment STAC Single Tee Adapter Clip Joins main beam or cross tee to wall �t �„�, Used to create code compliant non-seismic and / molding via locking barbs without pop I* rivets or screws. l'INI4 seismic C and D,E,Foff-module main beam to li cross tee connections. I �\ OP STAC 120 Illik�.� GCWA 250 FZSTAC 50 FZGCWA 50 C C1430 Variable Placement Hook Clip elk III 1..,Attach to T-Bar to create special length tees and • position anywhere along • the main beams. 11.113. C1430 120 • FZC1430 50 DETAILS m m-1 i-- ve• iem) i 1smml H j INTERLUDES XL® 13t32. l no m 7/8"Hemmed Shadow Molding �� Main Beam INTERLUDE XL INTERLUDE XL Angle Molding Main Beam 1.ya Cross Tee ye (44mm) (Mmmi -� a 7/9' (22mm) _ INTERLUDE XL sna^ slit 17.1 i Cross Tee w,a I ro;) I` I A air 1 (32 Pen) n+mml,� el SEISMIC PERFORMANCE Main Beams Cross Tees ICC Reports 6101 HRC,6127AHRC,6195AHRC XL6110HRC,XL6120HRC,XL6140HRC,XL6150AHRC, For areas under ICC jurisdiction,see ICC evaluation report Minimum Lbs.To Pull Out Compression/Tension XL6161 HRC,XL6162HRC,XL6164AHRC,XL6167HRC, number ESR-1308 for allowable values and/or conditions of 411. 329.0 XL6170HRC,XL6180HRC,XL6190HRC use concerning the suspension system components listed on Minimum Lbs.To Pull Out Compresslon/Tenslon this page.The report Is subject to reexamination,revisions,and 373.0 possible cancellation. To derive maximum lbs/SF,divide the on-center spacing of the component into the lbs/LF given In the load test data table. PHYSICAL DATA Material Cross Tee/Main Beam Interface End Detail Hot-dipped galvanized steel Flush fit and center protrusion Main Beam:Coupling I Surface Finish Design Considerations Cross Tee:Staked-on XL clip Baked polyester paint or powder-coated finish Physical product samples for standard and custom colors are Duty Classification Manufactured and tested in accordance available upon request.Please refer to the physical product Intermediate or Heavy-duty % with ASTM C635 sample prior to making a final selection.While we strive to Cleaning&Disinfecting me Face Dimension ensure exact color matches,various factors such as differences Cleaning and CDC-approved disinfecting options ,� 9/16" in materials,texture,substrate porosity,painting processes, available on armstrongceilings.com/cleaning) tsk lighting,and observer subjectivity can all affect how paint colors Profile appear on ceiling and wall panels,suspension systems,and trim Nib Dimensional tee products.Due to these and other differences,ceiling and wall panels,trim products,and suspension systems with the same color name will coordinate but may not be an exact color match. Product is dye-lotted.Order sufficient initial quantities and attic stock to minimize possible color variation. ///.��� �i TechLine/1 877 276-7876 LEEDx is a tademaze of me U.S.Green Building Coerce,Declare',and limySui.ning Charenge-(LBC)are ,/"'y ins`ronga armstrongceilings.comAnterlude trademarks at the International Living More Institute;WELL"and WELL Building Standard are trademarks `/ of the International WELL Building Institute;UL and UL Certified are trademarks of UL LLC;all other trademarks BPCS-4329-1121 used herein are the property of Awl Licensing LLC and/or its affiliates C 2021 Awl Licensing LLC CEILING&WALL SOLUTIONS ... s~. LYRA® PB Concealed with Plant-based Binder SUSTAIN' 2 a 7 High Performance DEFEND" SusConcealed Suspension Ceiling ms e Sdutions Salerfor SpacesHealthier. smooth texture CONTAIN PROTECT CAD/Revit'®drawings at: armstrongceilings.com/cadrevit DESIGNFIex` A New World of Choice for Ceiling Systems � r y.' ` 0xA 1.`, n^ e s`,.rr, p a 7:41.,t i.,'". v,,, a * lik :: ^""Mii I"' 1s ',., .`t�'.A x e .,' 1. a f .a�*, a„.a t , , . .,,,,,i • „i m - plus casabilities °Lk `1;µ . a, ' yy�� g} Lyra®PB Concealed panels with Prelude XL'15/16"suspension system armstrom/ a See more photos at. armstrongceilingscom/photogalleongceilings.ccap bilities ry Smooth,drywall-like visual with fully-concealed suspension and downward accessibility; Ideal for projects where plenum space is limited.Offers high sound absorption. KEY SELECTION ATTRIBUTES • Large format the Sustain®ra®PB nportfolliio,andsmeetpthe most . Downward accessible for minimal ustical panels ` • � dis nfectable'panels,suspends on systems, ' f n sh y saving,high light reflective il Istringent industry sustainability compliance plenum height and trim 30-Year Limited System Warranty standards today • Outstanding acoustical performance for • Mold-and mildew-resistant surface against visible sag,mold,and mildew • DesignFlex®options include made-to-order open plan areas,both Noise Reduction and • Smooth,clean,durable finish Washable, Available with factory-cut holes for sizes and colors available to ship in 3 weeks Articulation Class NRC 0.90,AC up to 190 Scratch-resistant,Soil-resistant USAI''trimless downlight fixture integration 1 COLORS Due to printing limitations,shade may vary from actual product. e v5 White Available NJIII any color!in Custom Color: Filz Felt Olive DETAILS 1.Lyra®PB Concealed 2.Lyra'®PB Concealed with Prelude®XL®HD 15/16"suspension system ilial ® TechLine 877 276-7876 1mstrong CEILING&WALL SOLUTIONS armstrongceilings.com/lyraconcealed Q RECYCLED Si Calculate sustainability with GreenGenie o.s 0 CONTENT ' armstrongceilings.com/greengenie Lu n LYRA® PB Concealed HI$SUSTAIN' 0 C G' 10 ! rid ( OIO .,� Sustainable Ceiang Systems UJ E iw� with Plant based Binder (white only) =E�1 "s=•, ®c�E ran, Concealed Suspension cREENcuARD y H �= w v a ��:=E n ee��_�c�ee_�r� o c 3 Y erti470eC. Gold Ce f'Ed ec+E aei3 mE v4 :8e ESIEt° E5__ 3E - smooth texture (details below) LOCATION DEPENDENT , VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. $$$$ 810- Humi- CleartAssure DURABILITY t. Block Guard+ . c Disinfectablo Panels y O _C J fail uL tO € K% i'3 E1 'W # U VUL Classified ?o `_a d _ m ee w 5 `� "- Acoustics z` ¢ c� 3 ci A I g armstrongceilings. Susp. Dimensions NRC coin/catdwgs Dwg. Item No. (Inches) 0+t,r, .. 0 0 0 �� 0 3 0 0 LYRA®Concealed 1 8430PB 30 x 30 x 7/8" ❑ 0.90 N/A N/A 190 Class 0.88* • • • AC Quick Kerr --—Edge 8433PB 24 x 48 x 7/8"I I 0.90 WA WA 190 Class 0.88* • • • A • A n 8431 PB 24 x 72 x 7/8"( 1 0.90 N/A WA 190 Class 0.88* Non-support 8432PB 24 x 96 x 7/8"I I 0.90 N/A N/A 190 Class 0.88* • • • • • lip • A • • — Edge 8434P8 48 x 48 x 7/8" 0.90 W190 aimA N/A 0.88* • • • • A rr 7/8"Thick Made-to-Order 1 Ctn Min Width Length WA N/A N/A N/A Class 0.88* • . . • • �44 Sizes ASTSIZ: 4"-30" 9•-96" Visit the product page 3 WEEKS 30-1/2"-48" online and see'Configure order to ship an ttem'to verity capabilities. Questions?email Techllneeeermetrortpce 1Qs.com _-.. 1 Total Acoustics®ceiling panels have an ideal combination of sound absorption and sound blocking in one product. *Advertised values for light reflectance,wash and Oi GOOD(NRC 0.60-0.65;CAC 35+) BETTER(NRC 0.70-0.75;CAC 35+) BEST(NRC 0.80+;CAC 35+) scratch resistance are applicable to white tiles only FIXTURE TRIM ACCESSORIES (must be ordered separately) Item No. Color Length Pcs/Cln Rani No. `•~' CTK4ZW Blizzard White 4"Concealed Fixture Kit 24 441 Border Clip for Vector®panels(required for installations with the suspension system - CTK6ZW Blizzard White 6"Concealed Fixture Kit 24 � resting on the wall molding).Primarily used for corners and special cutouts y CTK24ZW Blizzard White 24"Concealed Fixture Kit 24 442A ', Hold-down Clip for Vector®panels(for all installations) �� I. CTK48ZW Blizzard White 48"Concealed Fixture Kit 24 CTK72ZW Blizzard White 72"Concealed Fixture Kit 24 7425(24") 7431(30"),7445(48"),7461(60")Stabilizer Bars CTK96ZW Blizzard White 96"Concealed Fixture Kit 24 w i _ 523 = Midpoint Clip(Needed for panels over 30"wide) Other Size Blizzard White 4"to 96"Trim Pieces - — Fbthme Dims (custom colors available) — 7870 Spring Border Clip .110 Fixture trim kits Include 24 straight trim pieces and required speed clips. (For Installations with the panel resting on the wall molding) Example:For a space with 24"x 48"fixtures,order(1)24"kit CTK24ZW " and(1)48"kit CTK48ZW This will frame(12)24"x 48"fixtures. AXIOM®TRIM DETAIL Lyra®Concealed Panel SUSPENSION SYSTEMS Fixture Prelude®Grid ■ Lyra®Concealed panels with 15/16" r4s 1 Axiom®Vector trim for cloud friendly �m design.Blizzard White color and r u texture coordinated finish available Quick Kerr Edge Non-support Edge to complement Lyra ceiling panels. Lyra•Concealed Trim Kit 'Prelude*XL.HD i Speed Clip PHYSICAL DATA VOC Emissions PRODUCT UNWIRED 1 Physical product samples for standard and custom colors are GREENGUARD Gold Certified FOR LflHHeMCAL OL available upon request.Please refer to the physical product Material Third-party certified compliant SIONS ULCO Mcc sample prior to making a final selection.While we strive to Fiberglass with acoustically transparent membrane. with California Department of I11.2ete ensure exact color matches,various factors such as differences Public Health CDPH/EHLB/Standard in materials,texture,substrate porosity,painting processes, Surface Finish Method Version 1.2,2017.This standard Is GREENGUARD lighting,and observer subjectivity can all affect how paint colors •• Acoustically transparent membrane with the guideline for low emissions in LEED®,WELL'" Coro appear on ceiling and wall panels,suspension systems,and trim factory applied latex paint Building Challenge,Living Building Challenge® J products.Due to these and other differences,ceiling and wall •• Fire Performance (L8C),CalGreen Title 24,ANSI/ASHRAE/USGBC/IES panels,trim products,and suspension systems with the same Class A:ASTM E84 and CAN/ULC S102 surface Standard 189;ANSI/GBI Green Building Assessment Protocol. color name will coordinate but may not be an exact color match. burning characteristics.Flame Spread Index of 25 or Product is dye-lotted.Order sufficient initial quantities and attic High Recycled Content less.Smoke Developed Index of 50 or less(UL labeled) stock to minimize possible color variation. No- Contains greater than 50%total recycled content.Total recycled ASTM E1264 Classification content based on product composition of post-consumer and pre- Installation Consideration Type XII,Form 2,Pattern E;Fire Class A consumer(post-industrial)recycled content per FTC guidelines. Lyra®Concealed panels must be installed on a square, Humidity/Sag Resistance Acoustical Details level suspension system as tolerance is near zero. HumiGuard®Plus ceiling panels are recommended CAC backing may be available as a special order. Cleaning and Disinfecting - for areas subject to high humidity,up to,but not Cleaning and CDC recommended disinfecting options Insulation Value including,standing water and outdoor applications. R Factor-3.5(BTU units);R Factor-0.62(Watts units) available on armstrongceilings.com/cieaning Anti-Mold/Mildew 30-Year Performance Guarantee&Warranty w Ceiling panels with BioBlock®performance resist the Design Considerations When installed with Armstrong®Suspension System. 1110 growth of mold and mildew on the tile surface. Use fixture trim kit around all lights,diffusers,and other Details at armstron ceilln s.com/warrran y ceiling penetrations to avoid exposed suspension system and panel 9 9 tyu. edges.Panel sizes less than 24"x 24"are not Weight;Square Feet/Carton la recommended for full-field installations. 8430PB-0.55 lbs/SF;75 SF/ctn Border panels in a seismic installation will not be accessible. 8431PB-0.55 lbs/SF;72 SF/ctn To ensure border panels are accessible in other areas,consult 8433PB,8432PB-0.55 lbs/SF;96 SF/ctn installation instructions section 3.7.2 8434PB-0.55 lbs/SF;64 SF/ctn Minimum Order Quantity 1 carton TechLine/1 877 276-7876 LEED*is a trademark of the U.S.Green Building Council;Living Building Challenge"(IBC)Is a trademark of the ®rmstrong® armstrongceilings.coin/lyraconcealed International living Future Institute*;WELL'and WELL Building Standard am trademarks of the International WELL Building Institute;UL and UL Certified are trademarks of UL LLC;USA'Lighting is a trademark of USA Lighting,LLC: BPCS-5344-621 all outer trademarks used herein are the property otAOt Licensing LLC and/or its affiliates C 2021 AWI Licensing LLC CEILING&WALL SOLUTIONS AXIOM® Classic SUSTAIN' 24/7 Trim High Performance DEFEND' Sstraight&curved Ceiling Systeemms Solutions Spaces�ier, CONTAIN CLEAN PROTECT i Irk., ,'''' "" ,„ 4...........„.....,,,.,,„_. / / Axiom Classic Trim Custom slotting,perforating,and cutouts available for this Axiom®product. This extruded aluminum perimeter trim is a solution for use as exposed custom decorative trim with suspended panels or drywall. KEY SELECTION ATTRIBUTES • Adjustable Trim Clip(7239)makes Axiom® • Axiom®trim is part of the Sustain'" • Eight profile heights • Colors coordinate with Armstrong® Classic Trim compatible with WoodWorks® portfolio and meets the most stringent • Compatible with Armstrong®Suspension ceiling and suspension systems and Metal Works*panels that drop greater industry sustainability compliance Systems and Drywall Grid Systems • Design flexibility for straight and than 3/8"below the grid flange standards today • Finely articulated drywall trim with curved applications • Crisp-edge detailing and excellent • CleanAssure'"family of products— beaded edge integrates with all trim • 10-Year Limited warranty, corrosion resistance compared to includes disinfectable panels,suspension profiles for pre-engineered 30-year system warranty roll-formed steel systems systems,and trim(Cleaning and CDC drywall transitions ', • Dynamic curving capabilities available approved disinfecting options available on armstrongceilings.com/cleaning) COLORS Due to printing limitations,shade may vary from actual product. POWDER COATED FINISHES Standard NOTE Powder-coated i "t • s�� ,, finishes available on ' °' select Axiom.Classic, White Ivory Medium Taupe Light Grey Grey Stone Tech Black Silver Satin Silver Grey Gun Metal Basalt Riverstone Blizzard Charcoal Knife Edge',and Vector (WH) V) (MT) (LG) (GS) (BL) (SA) (SG) Grey(MY) (SB1) (SRV) White(ZW) Black(ZB) trim profiles f'°,73.3 /2v ci., (7:i,, C.:-'"': (7,34',.1. (::: (:-4::t ' e Ca, e Polar Limestone Fossil Sandstone Hay Oat Mist Pacific Rainstorm Lilac Twilight •Colors that am pre-qualified to meet Sustain'portfolio (SPO) (SLM) (SF) (SSS) (SW) (SOT) (SMT) (SPC) (SRS) (SLC) (STT) ',4' requirements are available upon e t" fa t;. t r'j , `'� request Other made to order a. + e +:/ +'> a` v�°,,,„% colors must be evaluated d is' - .0 sustainabil cntena is required "% i v:^ �r� : Lead time will increase. "` NOTE:360'paint finishes and Coffee Ocean Boxwood Fern Ivy Feldspar Topaz Bronzite Honeysuckle Marigold Rose Available in Any RAL or custom rows available as (SCE) (SOC) (SSW) (SFN) (SIV) (SFS) (STZ) (SBZ) (SHS) (SMG) (SRO) Custom Color' special order. TechLine 877 276-7876 (Amstrong armstrongceilings.com/axiomclassic CEILING&WALL SOLUTIONS i 0 i RECYCLED m 50 70!a i Calculate sustainability with GreenGenie' J CONTENT i armstrongceilings.com/greengenie AXIOM® Classic SUSTAIN' ; I ai " m' ' I High Performance E �E _y _ i m m i C I > ='I i ., Trim Sustainable Ceiling Systems its`; c Q W C n Igt. m i gE,_$ m W 1 z, straight&curved Declare. 3E s3 °E of E imei5'aE °-'S EWlErtigEl_mob: R LOCATION DEPENDENT VISUAL SELECTION Item No.♦ Description Dimensions AXIOM®Classic AX2STR___ 2"Straight 120 x 3/4 x 2" straight __ 3"Straight 120 x 3/4 x 3" 6I V AX4STR___ 4"Straight 120 x 3/4 x 4" DEE AX6STRB4_ 6"Straight 120 x 3/4 x 6" AXSSTR___ 8"Straight 120 x 3/4 x 8" AX10STR___ 10"Straight 120 x 3/4 x 10" fib' AX12STR___ 12"Straight 120 x 3/4 x 12" AX14STR*___ 14"Straight 120 x 3/4 x 14" AX16STR*___ 16"Straight 120 x 3/4 x 16" O Curved AX2CUR*___ 2"Curved Very x 3/4 x 2" AX3CUR*___ 3"Curved Vary x 3/4 x 3" AX4CUR*___ 4"Curved Vary x 3/4 x 4" AX/ R"___ 6"Curved Vary x 3/4 x 8" AX8CUR*___ 8"Curved Vary x 3/4 x 8" AX16CUR*_ 10'Curved Vary x 3/4 x 10" AX12CUR*___ 12'Curved Vary x 3/4 x 12" AX14Ct *___ 14"Curved Vary x 3/4 x 14" AX16CUR*___ 16"Curved Vary x 3/4 x 16" *Not available In architectural film finishes. i Add the 2-digit color suffix to the Item number when specifying or ordering(Example:Ax2STR Lis),add an extra digit'3"before the color suffix if paint is required inside and outside of trim(Example:Ax2STR 3 d AL Trim Channel:Aluminum extrusions formed with distinct architectural detail groove on top and 3/4"-. I-- bottom flanges and special bosses to receive the T-Bar Connection Clip,Hanging Clip,and Splice Plate,to provide positive mechanical lock with no visible fasteners.Factory-finished to match 3/4" r WV approved samples.Factory or field-cut,mitered,and curved to match approved shop drawings. Or- - 3/4"-i F l 3/4" " WV 3/4' 14" I -E 3. 3/4" I_ 12" 3/4"--I r 7-13/16' IP- r �4. 6-13/16" 3/4"1•-- 3-7/8" r 1-15/16" NOTE No architectural L — L._ .,5 — detail groove MD .4611 TechLine 877 276-7876 (^;rmstronge armstrongceilings.com/axiomclassic CEILING&WALL SOLUTIONS AXIOM® Classic SUSTAIN' 24/7 Trim High Performance DEFEND' Sustainable Solutions for Healthier, straight&curved Ceihng Systems Safer Spaces CONTAIN CLEAN PROTECT . VISUAL SELECTION Item No.+ Description Dimensions es Dynamic Curved AX2DCCt___ 2"Axiom Classic Dynamic 120 x 3/4 x 2" _I� ,�, Corners Curved Corner(STR-CUR-STR) Ei3-2" I 2'41�" AX4DCCt___ 4"Axiom Classic Dynamic 120 x 3/4 x 4" Outside Curve Curved Corner(STR-CUR-STR) Face Side -------► DCC1 DE F rm AX3DCCt___ 3"Axiom Classic Dynamic 120 x 3/4 x 3" a'-11 11/18• Curved Corner(STR-CUR-STR) 2'-10 5/8" 1 2'-11 7/8"� (Th • AX6DCGt___ 6"Axiom Classic Dynamic 120 x 3/4 x 6" Curved Corner(STR-CUR-STR) AX80CCt___ 8"Axiom Classic Dynamic 120 x 3/4 x 8" ' Rr-10 2'-2 11/16" Inside Curve Curved Corner(STR-CUR-STR) Face Side DCC4 AX1 ODCCt___ 10"Axiom Classic Dynamic 120 x 3/4 x 10" Curved Corner(STR-CUR-STR)file 4'-1 1/2" AXI2DCCt___ 12"Axiom Classic Dynamic 120 x 3/4 x 12" tr Curved Corner(STR-CUR-STR) AXI40CC1___ 14"Axiom Classic Dynamic 120 x 3/4 x 14" Curved Corner(STR-CUR-STR) AX18DCCt___ 16"Axiom Classic Dynamic 120 x 3/4 x 16" Curved Corner(STR-CUR-STR) AXIOM®Classic AX120SCP__ 12"Outside Corner Post 7/8 x 7/8 x 12" Axiom corner posts eliminate miter cuts at Corner Posts* corners for a fast and easy installation. AX12ISCP _ 12"Inside Corner Post 3/4 x 3/4 x 12" Ii/Imo` , AX100SCP _ 10"Outside Come Poet 7/8 x 7/8 x 10" .,� sl AX10ISCP__ 10"Inside Corner Post 3/4 x 3/4 x 10" ® ® `j it AX8OSCP__ 8"Outside Corner Post 7/8 x 7/8 x 8" � ` ��` Axiom Outside Axiom Inside AX8ISCP_ 8"Inside Corner Post 3/4 x 3/4 x 8" Corner Post Corner Post AX6OSCP_ 6"Outside Corner Post 7/8 x 7/8 x 6" AX6ISCP 6"Inside Corner Post 3/4 x 3/4 x 6" s • AX4OSCP 4"Outside Comer Post 7/8 x 7/8 x 4" a a • AX4ISCP_ 4"Inside Corner Post 3/4 x 3/4 x 4" i AX2OSCP_ 2"Outside Corner Post 7/8 x 7/8 x 2" i • AX2ISCP__ 2"Inside Corner Post 3/4 x 3/4 x 2" t Multiple radii available in a single direction only. *Not available in architectural film finishes •Add the 2-digit color suffix to the tern number when specifying or ordering(Example:AX25TR HA),add an -of extra digit"3"before the color suffix If paint is required inside and outside of trim(Example:AX2STR 3 fig). ru x all TechLine 877 276 7876 (Armstrong° I armstrongceilings.com/axiomclassic CEILING&WALL SOLUTIONS RECYCLEDI ® m505' g Calculate sustainability with GreenGenie' Cr b J O N CONTENT 1 armstrongceilings.comlgreengenie AXIOM® Classic C�,+t'i�Ci�CI; ici SUSTAIN' 1,I E i El 1 Trim Sustainable C lei ngaSystems „� E v l i ",i 1 1v G i v u 1 12Sz i � straight&curved Declare: o �wi EmE 83 f vc a .mn,aE ;82E2i3 m LOCATION DEPENDENT ACCESSORIES Item No.• Description Dimensions AXIOM®Classic AX16QSOS*_ _ 16"Outside Comer 12 x 3/4 x 16" MINIMUM BEND RADIUS Pre mitered * Axiom factory-mitered inside and outside corner AXI6QSIS___ 16"Inside Corner 12 x 3/4 x 16" pieces are created to match your Axiom Trim FOR AXIOM CLASSIC PIP Corners AX14QSOS*___ 14"Outside Corner 12 x 3/4 x 14" channel order These corners come as 2"—12" 2",4",6",8"—24"Minimum AX14OSIS*___ 14"Inside Corner 12 x 3/4 x 14" long pieces that are assembled in the field for a 12"—36"Minimum AX12QSOS 12"Outside Corner 12 x 3/4 x 12" clean mitered corner intersection. 14"—60"Minimum D E F AXI2QSIS _ 12"Inside Corner 12 x 3/4 x 12" \ AXIOM FACTORY AX1 OQSOS___ 10"Outside Comer 12 x 3/4 x 10' MITER LIMIT AXI OQSIS __ 10"Inside Corner 12 x 3/4 x 10" * 2",4",6",8"—Minimum 30" SQSOS___ 8"Outside Corner 12 x 3/4 x 8" / '-o acute angle(16"per cut) AX �i 10",12",14",16"—Minimum 60" b. AX8QSIS___ 8"Inside Corner 12 x 3/4 x 8" Outside Corner acute angle(30"per cut) AX64SOS __ 6"Outside Corner 12 x 3/4 x 6" AX6QSIS _ 6"Inside Corner 12 x 3/4 x 6" AX4QSOS___ 4"Outside Corner 12 x 3/4 x 4" fit\/l AX4QSIS___ 4"Inside Corner 12 x 3/4 x 4" ir AX2QSOS___ 2"Outside Corner 12 x 3/4 x 2" Inside Corner JO AX2QSIS* 2"Inside Corner 12 x 3/4 x 2" *Not available in architectural film finishes f Add the 2-or 3-digit color suffix to the item number when specifying or ordering(Example:AX2OSIS U A), add an extra digit"3°before the color suffix if paint Is required Inside and outside of trim (Example:AX2OSIS 3 H A). ACCESSORIES Item No. Description AXAC Alignment Clip Sheet aluminum formed to fit into special trim channel bosses.Provides positive mechanical lock and screw-fastened1311 connection to suspension members that intersect below the trim channel. AX2HGC Hanging Clip Sheet aluminum formed to fit into special trim channel bosses.Provides positive mechanical lock and screw-fastened 8 connection to suspension members that intersect below the trim channel, AXTBCSS T-Bar Connection Clip Galvanized sheet steel formed to fit into special trim channel bosses.Provides positive mechanical I lock with factory-installed screw.Screw-fastened connection to suspension members that intersect 00"41"4"."%. the trim channel. y 7239 Adjustable Trim Clip � Allows Axiom®trim to be positioned up to 3-3/4"below the grid face to accommodate deeper panel offsets (best aesthetic with Axiom z 6"tali `i AXSPLICESS Axiom Splice Plate ./� We v0� AiSPLICE •. t z+AXSPLICE2 Axiom Splice Plate / a Galvanized sheet steel formed to fit into the trim channel bosses.Provides positive lock between abutting channels with factory-installed setscrews. AXSPUCE2 OP IP- PHYSICAL DATA Material Design Considerations Warranty i Commercial quality 3003 aluminum alloy Physical product samples for standard and custom colors are 10-Year Limited Warranty;30-Year System Warranty Surface Finish available upon request.Please refer to the physical product Profile Factory-applied baked polyester paint finish sample prior to making a final selection.While we strive to ensure Various options with both Ceiling-to-Wall and exact color matches,various factors such as differences in Ceiling-to-Cellin Light Cleaning 8 Disinfecting h g Ledges in a wide range of ta. Cleaning and CDC approved disinfecting options mat observer texture,r substrate porosity,pat howng paint processes, pe lighting, sizes with 3/4"horizontal flange. available on armstrongceilings.com/cleaning and oba derit subjectivitynes, can all affect ,adcomrp oduappears on Cross Tee/Main Beam Interface A ceiling and wall panels,suspension systems,and trim products. Flush fit Due to these and other differences,ceiling and wall panels,trim Am products,and suspension systems with the same color name will End Detail coordinate but may not be an exact color match.Product is dye- Splice with screws lotted.Order sufficient initial quantities and attic stock to minimize possible color variation. TechLine/1 877 276-7876 LEEm is a trademark of the D.S.Green Building Council;Declare'and Living Building Challenge* ( mstrong armstrongceilings.com/axiomclassic (LedJ are trademarks of me IntemaPanal Living Future Insfitute';WELL and wELL Building Standard are trademarks of the intemationai wELL Building insututei ail other trademarks used herein BPCS-30a0-1021 are the property of Awl Licensing LLC andlor no affiliates C 2021 Awi Licensing ac CEILING&WALL SOLUTIONS PRELUDE® XL® and PRELUDE XL High Recycled Content (HRC) SUSTAIN' 2 4/7 Exposed Tee Suspension System High Performance DEFEND' Sustainable Solutions for Healthier, Ceiling Systems Safer Spaces CONTAIN PROTECT This hot-dipped galvanized steel 15/16"suspension system offers high recycled content for improved LEED®credits. KEY SELECTION ATTRIBUTES • Seismic Re Suspension System saves time • 10-Year Limited System Warranty;30-Year Limited A 4 and money;Armstrong Ceilings offers an ICC-ES Ceiling Systems Warranty when used with approach to installations(ESR-1308) HumiGuardm Plus products • Preludes XL*is part of the Sustain'portfolio • Made-to-order main beams and cross tees can be 1 11 ''">.,` and meets the most stringent industry ordered for your project needs in one carton minimum •.. sustainability compliance standards today •Available with coating that resists dirt,bacteria,mold, • CleanAssure"family of products-includes mildew,and color fading DEE " _.- disinfectable panels,suspension systems,and trim • XLs staked-on end detail provides secure locked connection: •• - (Cleaning and CDC-approved disinfecting options easy to remove,reuse,and relocate • available on armstrongceilings.com/cleaning) • Fire Guard"'options offer ULA design fire-rated performance PeakForms profile increases .� • Some items available in metric sizes strength and stability for improved ,y , performance during installation • Blizzard White and Charcoal Black powder-coated finish Prelude XL suspension system • SuperLock'main beam clip is engineered for • Linear lighting integration is easy with made-to-order a strong,secure connection and fast,accurate main-beam-to-cross-tee adapters,rout spacing,miter C► alignment confirmed with an audible click; spacing,and short cross tees fill V easy to remove/relocate (3"to 6"lengths) • Hot-dipped galvanized coating inhibits red rusting 10-Year replacement p0-YE•AR better than electrogalvanized or painted systems items available AVAILABILITY COLORS Due to printing limitations,shade may vary from actual product. 41 Standard Premium • III 40 „gt,..;:t....r ,,:.,, saLV ° Ili White Tech Black Silver Grey Gun Metal Silver Satin Ivory Medium Taupe Light Grey Grey Stone Custom Colors Camel White Aluminum Natural OW) (BL) (SG) Grey(M`) (SA) (IV) (MT) (LG) (SS) Available* (CM) (WA)T Aluminum(NA)t ,..4) ,„,, • ,....„ ,....„ /„., „. lel ,,,., Basalt Rlverstone Coffee Polar Limestone Fossil Sandstone Hay Oat Copper Bronze Pewter Silver ISBT) (SRV) (SCE) (SPO) (SLR (SFL) (SSS) (SHY) (SOT) (CP) (Hi (PV) (SL) f.. r / s r"' o `. Powder-Coated Finishes , r '` 1 �' , tl Mist Mi Pacific Rainstorm Lilac Twilight Ocean Boxwood Fern Ivy (SMT) (S�) (SRS) (SIC) (Sri) (SOC) (SBW) (SFM (SM Blizzard Charcoal P a 1�-.... White VW) Black(ZB) ill NOTE:360 paint finishes and custom Feldspar T Bronzite Hon ,, colors available as pa Topaz Honeysuckle Mangold Rose special order. 4111. MI (SFS) (STZ) (SBZ) (SHS) (SMG) (SRO) • •Colors that are pre-qualified to meet Sustain-portfolio requirements are available upon request. Other made-to-order colors must be evaluated if sustainability criteria is required.Lead ame will increase. i VISUAL SELECTION PERFORMANCE PACKAGING LOAD TEST DATA CleanAssure•" i (LBS./LIN.FT) ' cn o Disinfectable Grid v Ern a.. m iL ayy: ci, A0. rn U lQ vs- § C C Rout Dimensions U360 U360 //�� �Rn. r Item No.• Description Spacing (Inches) 4 Ft. 5 Ft. 0 fa Q Oa � .c, P - PRELUDE®XL® 73015L_ 12'HD Main Beam 6"0.C. 144 x 15/16 x 1-11/16" 16.73 8.73 N/A • • 20 240 15/16" N/A 20 240 • • • • 8301 20 240 - (Red Numbers 7300 12'ID Main Beam 6"0.C. 144 x 15/16 x 1-11/16" 8.73 6.35 N/A N/A • 20 240 are Fire Guard" 8300__tt N/A • • • 20 240 items) • 7305 140"HD Main Beam 10"O.C. 140 x 15/16 x 1-11/16" 13.5 8.73 WA • • • • 20 233 NOTE Additional Prelude XL items for TechZone.Ceiling Systems are listed in the TechZone Technical Guide(BPCS-4486), Dots represent high ASTM Class and available online at armstrongceiiings.com/techzone level of performance. HD- Heavy-duty 'Simple Span ••Hanger Wire Support Mid-Span ID- Imes-duly a-duty P P 9 LD- Light-duty •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the tern number(e.g.7301 L a_-Light Grey) :•Available in White(WH),and Blizzard White and Charcoal Black powder-coated finishes only tt Available in Tech Black(BL)and White(WH)only ttt Available In Tech Black(BL),White(WH),and Blizzard White and Charcoal Black powder-coated finishes only TechLine 877 276-7876 ®rmstrong• armstrongceilings.com/preludexl CEILING 8,WALL SOLUTIONS � a 0 RECYCLED Calculate sustainability with GreenGenie"" PRELUDE® XL® and L 0 CONTENT : armstrongceilings.com/greengenie PRELUDE XL High Recycled Content (HRC) -1 Hlah Performance L!.! E m _ -y Exposed Tee Suspension System Sustui eCellingsystema E -_ _a., =o E .�) Declare: E El E oc: E I E'.m n a E IA E VIET'.I E my LOCATION DEPENDENT WELL Building Standard"(WELL) Living Building Challenge•(LBC) VISUAL SELECTION PERFORMANCE PACKAGING I LOAD TEST DATA I T CleanAssure' ' (LBSJUN.FT.) d 52 S Disinfectable Grid v E c, s `N N 111N t` a tzi E rn § Rout Dimensions U360 U360 ©0 t j try tttLLL 1 .i Item No.• Description Spacing (Inches) 4 Ft. 5 Ft. r►+/ PRELUDE*XL• 7306__°'r 132"HD Main Beam 10",30",50",56",76", 132 x 15/16 x 1-11/16" 16.73 8.73 N/A 20 220 6 15/16" 96",116",122"0.C. 144 (Red Numbers 7307_ 126"HD Main Beam 10",30",50",70",90", 126 x 15/18 x 1.11/16" WA WA N/A • • • • 20 210 110",116°D.C. are Fire Guard's' terns) 10'ID Main Beam 6"O.C. 120 x 15/16 x 1.11/16" 13.5 6.35 WA WA • • • 20 200 -.,Vy,.- -_- _ _.__ ___. DE F 7302 10'ID Main Beam 6"0.C. 120 x 15/16 x 1-11/16" 13.5 6.35 WA WA • • • 20 200 XL7380 ++ 8'Cross Tee 12"O.C. 96 x 15/16 x 1-11/16" 12.12** N/A WA • • • • 20 160 XL7357__++ 5'Cross Tee 6",12",24",30",36", 60 x 15/16 x 1-11/16" N/A 7.61 WA • • • • 60 300 ` 48",54"0.C. +; V / XL7390$(�9L 6'Cross Tee 12"O.C. 72 x 15/16 x i•11/16" 12.24* WA N/A • • • • 20 120 �' XL7341__4• 4'Cross Tee 12"0.C. 48 x 15/16 x 1.11/16" 16.89 N/A WA • • • • 60 240 XL7341HRC WA • • • • 60 240 XL8341 60 240 XL7340__.• 4'Cross Tee 12"O.C. 48 x 15/16 x 1-11/16" 12.25 WA WA • • • • 60 240 XL8340__tt • • • • • 60 240 XL7342___ 4'Cross Tee 12"O.C. 48 x 15/16 x 1-1/2" 7.8 N/A N/A • • • • 60 240 Sp XL7348__•:• 4'Cross Tee 12"O.C. 48 x 15/16 x 1-3/8" 6.78 N/A N/A • • • • 60 240 XL7330__ttt 3'Cross Tee N/A 36 x 15/16 x 1-11/16" 20.3 at 3' WA WA • • • • 60 180 XL7378__ 30"Cross Tee N/A 30 x 15/16 x 1.3/8" 16.54 at 2.5' WA WA • • • • 60 150 XL7328___ 2'Cross Tee N/A 24 x 15/16 x 1-3/8" 36.0 at 2' WA N/A • • • • 60 120 XL8323__tt 60 120 XL8320HRC 2'Cross Tee N/A 24 x 15/16 x 1.11/16" 61.33 at 2' WA N/A • • • • 60 120 XL8320 60 120 XL7368_ 4• 20"Cross Tee N/A 20 x 15/16 x 1-3/8" 36.0 at 1.67' N/A WA • • • • 60 100 • XL7398__++ 18"Cross Tee N/A 18 x 15/16 x 1-3/8" WA WA WA • • • • 60 90 XL7318__•a 1'Cross Tee N/A 12 x 15/16 x 1-3/8" 38.0 at 1' WA WA • • • • 120 120 ' XL7304__4 4"Cross Tee N/A 4 x 15/16 x 1-11/18" N/A WA N/A • • • • 80 20 XL7306__♦ 6"Cross Tee N/A 6 x 15/16 x 1-11/16" N/A WA WA • • • • 60 30 1 Ctn Min -15/16"Prelude,'XL® Size Capabilities ASTSIZ:Main Beams Length WA WA WA WA WA WA WA WA WAN Vida NOTE:Up to 6 weeks 2 WEEKS 36"-144" for color and size order to ship combinations. Rout spacing 6"from ends,6"thereafter Made-to-order main beams and cross tees can be ordered with special sizes,rout spacing,and colors for your project needs In one carton minimums. Dots represent high •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the hem number(e.g.XL7342 L a_-Light Grey) level of performance. &Available in White(WH),and Blizzard White and Charcoal Black powder-coated finishes only tt Available in Tech Black(BL)and White(WM only • ttt Available In Tech Black(BL),White(WM,and Blizzard White and Charcoal Black powder-coated finishes only VISUAL SELECTION LOADTESTDATA PACKAGING . (LBS.AJN.FT.) s01 Face Dimensions ,, Item No. Profile Description (Inches) 4 Ft 5 Ft c`3 t Prelude XL AX73003___ 15/16" 12'ID Main Beam,Routs 6"0.C. 144 x 15/16 x 1-11/16" 13.5 6.35 20 240 Painted Grid to Match Axiom®Trim(360° AX73013__ 15/16" 12'HD Maln Beam,Routs 6"0.C. 144 x 15/16 x 1-11/18" 16.73 8.73 20 240 Painted-Powder AX73423__- 15/16" 4'Cross Tee,Routs 12"0.C. 48 x 15/16 x 1-1/2" 7.8 WA 60 240 Coated Paint) - AX73283___ 15/16" 2'Cross Tee 24 x 15/16 x 1-3/8" 36.00 2' N/A 60 120 I AX73183___ 15/16" 1'Cross Tee 12 x 15/16 x 1-3/8" 36.0 01' WA 120 120 AX73583___ 15/16" 5'Cross Tee Routs 6",20", 60 x 15/16 x 1-1/2" 7.61 N/A 60 300 ent and 30"from ends AX73793___ 15/16" 30"Cross Tee 30 x 15/16 x 1-3/8" 16.54 0 2.5 N/A 60 150 ® AX83403___ 15/16" 4'Cross Tee,Routs 12"0.C. 48 x 15/16 x 1-1/2" N/A N/A 60 WA AXAL7220___ 15/16" 2'Cross Tee 24 x 15/16 x 1-1/2" N/A WA 60 120 •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the tern number(e.a.7301 L B_-Light Grey) TechLine 877 276-7876 ®rmstrong• armstrongceilings.com/preludexl CEILING&WALL SOLUTIONS RECYCLED ® m '' Calculate sustainability with GreenGenie'" PRELUDE® XL® and a 0 CONTENT armstrongceilings.com/greengenie PRELUDE XL High Recycled Content (HRC) SUSTAIN. High Performance LL E E a,. - o 0. c •� Exposed Tee Suspension System Sustainable Cerfng Systems m E n g� iam E ccr Ec a a' I ern c 3' c Declare. mm E El t'E a r w W E !B m'8 E.re m E LOCATION DEPENDENT WELL Building Standard"(WELL) Living Building Challenge•(LeC) VISUAL SELECTION PERFORMANCE PACKAGING LOAD TEST DATA CleartAssure" • (LBS.AJN.FT.) .0c Disinfectable Grid '2 E IF,, a N V N LE ',58, S a' ,v c c Face Rout Dimensions U360 U360 ©�/yn Rl CD { r c Item No. Profile Description Spacing (Inches) 4 Ft. 5 Ft. III') a 8 8 01) Continuous CLP7301 15/16" N/A N/A 6 x 15/16" N/A N/A WA • • • • 20 240 Load Path 414 (CLP) 7396 15/16" 9'6"Main Beam 6"0.C. 114x 15/16" 16.5 8.73 WA • • • • 20 190 DEF 7376 15/16" 7'6"Main Beam 6"O.C. 90 x 15/16" 16.5 8.73 WA • • • • 20 150 Dots represent high AVM De level of performance. HD- Heavy-duly W. D- Intermediate duty LD- Lpht-duty VISUAL SELECTION PACKAGING Jo A ISO Item No.• Description Length FFllerpe Flange Reveal (Reveal is Suggested Wall 7800___ 12'Hemmed Angle Molding 144" 7/8" 7/8" N/A WA 30 380 Moldings and 7800HRC Shadow Moldings 7808__/." 10'Hemmed Angle Molding 120" 2" 2" N/A WA 10 100 780812_ :" 12'Hemmed Angle Molding 144" 2" 2" N/A WA 10 120 7807 10'Hemmed Angle Molding 120" 2" 1" N/A N/A 10 100 7875__":" 10'Shadow Molding 120" 3/4' 15/16" 1/2" N/A 30 300 7877__s:•""" 10'Shadow Molding 120' 15/16" 15/16" 1/4" WA 30 300 7878___*** 10'Shadow Molding 120" 15/16" 15/16" 3/B" WA 30 300 7897_`t*** 10'Shadow Molding 120" 15/16° 15/16" 1/2" WA 30 300 7888 10'Shadow Molding 120" 9/16" 15/16" 3/8" 1/4' 30 300 7850__ 10'Hemmed Angle Molding 120" 1-1/8" 7/8" N/A N/A 30 300 7851__4:.. 12'Hemmed Angle Molding 144" 1-1/8" 7/8" N/A N/A 30 360 *Simple Span **Hanger Wire Support Mid-Span ***Suitable for IBC Category D,E,F Installations using Armstrong*Seismic Rx•suspension system and BERC2 Clip •When specifying or ordering items with a color or finish,add the two-or three-letter suffix to the end of the item number(e.g.XL7342 L 6._-Light Grey) ":"Available in White(WM,and Blizzard White and Charcoal Black powder-coated finishes only MAXIMUM FIXTURE WEIGHT im Configuration Item Fixture Planning Module Hanger Spacing Maximum Weight A B No. I A B A B A B A B Main Beam to 1 7300/8300/7302 24"x 48' 24"x 48" 48"x 48 48"x 48" 48" 48' 69.27 lbs. 49.27 lbs. Main BeamF1 7301/8301 24"x 48' 24"x 48" 48"x 48 48"x 48" 48" 48' 72.32 lbs. 72.32 lbs. •S<"" 7300/8300/7302 12"x 48' 12"x 48' 48"x 48" 48"x 48" 48" 48" 54.26 lbs. 47.17 lbs. 7301/8301 12"x 48" 12'x 48' 48"x 48" 48"x 48" 48" 48" 100.0 lbs. 63.32 lbs. �_.._. - 7300/8300/7305 24'x 48" 20'x 60" 60"x 60" 60"x 60" 48" 48' 56.47 lbs. 43.21 lbs. l►�I 7301/8301 24'x 46" 20"x 60" 60"x 60" 60"x 60" 48" 48' 56.47 lbs. 65.46 text Main beams tested as follows:7300 tested at 13.0 Ibs./LF to 1/360 of 4'span;7301 tested at 16.5 lbs./LF to 1/360 of 4'span; AID 8500 tested at 13.3 Ibs./lin.ft.to 1/360 of 4'span 48 cross tee tasted at 10.34 lbs./lin.ft.to 1/360 of 4'span. XL6342 -.._ 24"x 48" 24"x 24" T 64"x 60" 48"x 48 --_s.-- Cross Tee t0 Diii XLd31000 7340 24"x 48" 24"x 24" 64 x 60" 48"x 48' 48" 48" 69.27 lbs. 80.55 tus. Cross Tee 1 1��1 48" 48" 40.89 lbs. 52.26�6. -di J It D-IC11 XL8340/XL7340 24"x 48" 12"x 48" 48"x 48" 48"x 48" 48" 48" 49.27 lbs. 42.17 lbs. • XL8341/XL7341 24"x 48" 12"x 48" 48"x 48" 48"x 48" 48" 48" 72.32 lbs. 63.32 lbs. Fixtures weighing more than 56 lbs.should be Independently supported.Ebdure weight is based on single fixture only.For end-to-end Mures or other configurations not shown,consult your Armstrong Ceilings representative. NOTE:The above data is based on 48"hanger wire spacing,board weight of 1 Ib/SF,maaimum deflection of tees not to exceed 1/360 of the span,and suspension system Installed in accordance with ASTM C636. TechLine 877 276-7876 (Jrmstrong• armstrongceilings.com/preludexl CEILING&WALL SOLUTIONS Q RECYCLED e m a Calculate sustainability with GreenGenie'" PRELUDE®XL® and Q 3 0 CONTENT Calculate PRELUDE XL High Recycled Content (HRC) —Li �1�` 0 1 SUSTAIN' I ,o�� Ior High Performance E 'E w 130 c or c a,E m 23 Exposed Tee Suspension System SustainableCelingSystems E�m =_ We0 m_ ZE =r,'mm=1£A — Decktrem. om owl �o1yo:,gym uE o$p,mo )• m N mN aml O y'T•i Q6 i•E �a E, 3 E ml S i3aE m mEcm:.,oE.— m LOCATION DEPENDENT WELL Building Standard'"(WELL) Living Building Challenge"(LOC) ACCESSORIES a= . i U Item No. Description d Item No. Description a a BERC2 2"Beam-End Retaining Clip ES4 Expansion Sleeves Allows you to create a code-compliant Seismic • • For 15/16"Prelude 4' D,E,F ceiling installation while eliminating the • (\� 4 need to use 2"wall molding or spreader bars. 4. i, BERC2 Steel 200 sal' FZBERC2 Steel 50 eik......., ES4 200 D. ALBERC2 Aluminum 200 I F1ES4 50 FZALBERC2 Aluminum 50 GCWA Grip Clip Wall Attachment g Adapter STAC Single-Tee ClipJoins main beam or cross tee to wall • molding via locking barbs without pop Used to create code-compliant non seismic and r I, -seismic C and D,E,Foff-module mom beam to wets or screws. ��• cross tee connections. Ci STAG 120 GCWA 250 FZSTAC 50 FZGCWA 50 Eib s JP DETAILS 4-1/4•(emm) viz°(6mm) PRELUDE®XL® PRELUDE XL 1 �16, PRELUDE XL ens° 7/8"Hemmed 15/16"Hemmed Continuous • Main Beam Main Beam (14mm) 1 Cross Tee (14mm) Angle Molding Shadow Molding Load Path n 1-11/16° li • 1(143mm) (� m) sna• •et' PRELUDE XL i02.01 �''l� e Cross Tee ! L. 1" I ee' --I Rene• 1— (24mm) 1- r�' a CLP7301—20 pcs amm) aamM • SEISMIC PERFORMANCE Main Beams Cross Tees ICC Reports 7301,7301 HRC,7306,7307,8301 All XL cross tees exceed 300 lbs.in both For areas under ICC jurisdiction,see ICC evaluation report number ND Lbs.To Pull Out Compression/Tension compression and tension. ESR-1308 for allowable values and/or conditions of use conceming 335.0 the suspension system components listed on this page.The report i 330.0 is subject to re-examination,revisions,and possible cancellation. PHYSICAL DATA Material Design Considerations End Detail Hot-dipped galvanized steel Physical product samples for standard and custom colors are Main Beam:Staked-on clip i Surface Finish available upon request.Please refer to the physical product sample Cross Tee:Staked-on clip Baked polyester paint or powder coated prior to making a final selection.While we strive to ensure exact Duty Classification color matches,various factors such as differences in materials, Manufactured and tested in accordance Intermediate or Heavy-duty C with ASTM 635 texture,substrate porosity,painting processes,lighting,and observer Cleaning&Disinfecting subjectivity can all affect how paint colors appear on ceiling and Face Dimension wall panels,suspension systems,and trim products.Due to these Cleaning and CDC-approved disinfecting options available 4m •, 15/16" and other differences,ceiling and wall panels,trim products,and on armstrongceilings.com/cleaning) A Profile suspension systems with the same color name will coordinate Exposed tee but may not be an exact color match.Product is dye-lotted.Order .40 Cross Tee/Main Beam Interface sufficient initial quantities and attic stock to minimize possible Override color variation. /� TechLine/1 877 276-7876 LEER.Is a registered trademark of the U.S.Green Budding Council,Declare'and Laing Building Challenge" @,mstrong® armstrongceilings.com/preludexl ABC)are registered Uademarks or the international Living Future Institute';WELL'and WELL Building Standard"are trademarks of the hdemaoonal WELL Building Institute;all other trademarks used herein BPCS-3344-1121 are the property of AWI Licensing LLC and/or its affiliates 0 2021 Awl Licensing LLC CEILING&WALL SOLUTIONS EStcc EiAu non sERvrCE ICC-ES Evaluation Report ESR-1308 • Reissued December 2020 This report is subject to renewal December 2021. www.icc-es.orq I (800)423-6587 ( (562) 699-0543 A Subsidiary of the International Code Council" DIVISION:09 00 00-FINISHES 7305, 7500,7502,6500B,EA7900.7600,and 76008 7602. Section:09 22 26-Suspension Systems 76028, 7603, 76038, 76068, 7607, series.All members are Section:09 53 00-Acoustical Ceiling Suspension classified as intermediate-duty in accordance with ASTM Assemblies C635, except the following, which are classified as heavy- duty: 6501, ES7901, EA7903, 6101, 6121A, 6127A, 6132, REPORT HOLDER: 6195A, 7301, 7306, 7307, 7501, 7504, 7507, 7508, 7509, 7601, 7604, 7605, 7612, 76128, 76018,76048 and 76058. WORTHINGTON ARMSTRONG VENTURE(WAVE) Profiles of runners are shown in Figure 1. The 7300 and 7500 runners are cold-formed from ASTM EVALUATION SUBJECT: A568 steel. The runners have a hot-dipped galvanized FIRE-AND NONFIRE-RESISTANCE-RATED coating and a factory-installed polyester-painted steel cap SUSPENDED CEILING FRAMING SYSTEMS or aluminum cap along the entire length of the bottom flange. The 6100, 6101, 6500B, 6501, ES7901,7600, and LISTEE: 7601 series have a painted coating in addition to the hot- ADDITIONALdipped galvanized coating, and have no cap. The AL 7200, ARMSTRONG WORLD INDUSTRIES,INC. EA7900 and EA7903 runners are cold-formed from 3003- H14 aluminum and have a baked polyester paint coating. 1.0 EVALUATION SCOPE The 6500B, 6501 and ES7901, EA7900 and EA7903 runners have a polyurethane-filled upper bulb in addition to Compliance with the following codes: a polyurethane-coated lower flange. ■ 2018,2015,2012,and 2009 International Building Code"' The ES7901C runners are cold-formed from ASTM A568 (IBC) steel; have a painted coating in addition to the hot-dipped • 2013 Abu Dhabi International Building Code(ADIBC)t galvanized coating; a factory-installed polyester-painted IThe ADIBC is based on the 2009 BC.2009 IBC code sections referenced steel cap ; and include an integral extruded PVC gasket. in this report are the same sections in the ADIBC. The ES7901 C main runners are classified as heavy-duty in For evaluation for compliance with codes adopted by Los accordance with ASTM C635 and shall be used in Angeles Department of Building and Safety (LADBS), see conjunction with ES7920C and ES7940C cross runners ESR-1308 LABC Supplement, listed in Table 3 of this report. For evaluation for compliance with codes adopted by The EA7900C runners are cold-formed from 3105-H24 California Office of Statewide Health Planning and aluminum and have a baked polyester paint coating and Development(OSHPD)and Division of the State Architect include an integral extruded PVC gasket. The EA7900C (DSA),see ESR-1308 CBC Supplement. main runners are classified as intermediate-duty in Properties evaluated: accordance with ASTM C635 and shall be used in conjunction with EA7920C and EA7940C cross runners • Interior finish listed in Table 3 of this report. ■ Fire resistance The SS 7200 runners are cold-formed from 300 series • Structural stainless steel complying with ASTM A480. Table 2 2.0 USES specifies dimensions, lengths, and allowable transverse The Worthington Armstrong Venture (WAVE) ceiling loads. framing systems described in this report are suspended, 3.1.2 EAC Main Runners, Low Voltage, Nonfire- exposed framing systems of ceiling assemblies resistance-rated: Main runners for use with low voltage used in fire-resistance-rated and nonfire-resistance-rated powered lighting systems include the following: EAC construction for interior applications. Prelude Main Runners:DC730112,DC730110,DC730108, 3.0 DESCRIPTION and DC730106;non-powered 730106:EAC Suprafine Main Runners: DC750112, DC750110, DC750108, and 3.1 Grid Components: DC750106; the non-powered 750106:EAC Silhouette Main 3.1.1 Main Runners, Nonfire-resistance-rated: Main Runners: DC760112, DC760110, DC760108. and runners for use in nonfire-resistance-rated ceiling DC760106; and the non-powered 760106. The EAC assemblies include the 6100,AL7200,SS7200,7300,7302, Prelude, EAC Silhouette,and EAC Suprafine are classified ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not cpeeifit ally addressed,as sed,nor are they to be construed M 0 as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC'Evaluation Senn....I.LC,express or implied,as k to nay finding or other mutter in this upon,or as to any product covered by the report. Copyright s 2020 ICC Evaluation Service.LLC.All rights reserved. Page 1 of 21 Arimigur ESR-1308 I Most Widely Accepted and Trusted Page 2 of 21 as heavy-duty In accordance with ASTM C635.See Table 2 structurally as Intermediate-duty in accordance with ASTM for the listed runners, and Figure 1 for a profile of these C635; Models 8301, 8501, and HD 8201 main runners are runners. classified as heavy-duty. Profiles of runners are shown in The EAC main runners are cold-formed from ASTM A568 Figure 1. steel. The runners have a hot-dipped galvanized coating All members have an inverted T shape. Members are and a factory-installed,polyester-painted steel cap along the cold-formed from ASTM A568 steel with a hot-dipped entire length of the bottom flange. The EAC Silhouette galvanized coating. series has a painted coating in addition to the hot-dipped Models 8300, HD 8201 and 8301 have a factory-installed galvanized coating and have no cap on the bottom flange. steel cap along the entire length of the bottom flange. The The EAC Prelude, EAC Silhouette, and EAC Suprafine HD 8201 member has a hot-dipped galvanized coating and main runners have a snap-on upper polymerprofile that a bottom flange cap made from either 3003 H16 or 3105 supports two tin-plated copper conducted strips that serve H16 aluminum. Table 2 specifies dimensions, lengths and to carry the low voltage current. The EAC Silhouette main allowable transverse loads. runners also have a lower conductive snap-on polymer 3.1.6 Cross Runners, Fire-resistance-rated: Cross conductive strip in the lower box profile in addition to the runners for use in fire-resistance-rated ceiling assemblies upper conductive snap-on polymer profile. The snap-on are the XL 8200 series (Prelude Plus Fire Guard), XL 8300 polymer has a flame-spread index of 25 or less and a series (Prelude Fire Guard), and XL 8500 (Prelude smoke-developed Index of 50 or less, when tested in Suprafine Fire Guard) series runners listed in Table 3. accordance with ASTM E84. Profiles of runners are shown in Figure 1. Members are The EAC main runners are used in conjunction with the cold-formed from ASTM A568 steel with a hot-dipped XL 7300 (Prelude), XL 7500 (Supraflne) and XL 7600 galvanized coating. The XL 8300 and XL 8500 series have (Silhouette)cross runners listed in Table 3 of this report. a factory-installed steel cap along the entire length of the bottom flange. The XL 8200 series members have a 3.1.3 Main Runners, Gravity Loaded, and Nonfire- hot-dipped galvanized coating and a bottom flange cap resistance-rated: Main runners for use to support gravity made from either 3003-H16 or 3105-H-16 aluminum.Table loads only in non-fire-resistance-rated ceiling assemblies 3 specifies dimensions, lengths and allowable transverse include 730145 series. The suspended ceiling framing loads. system must be installed in accordance with the IBC Section 3.1.7 Cross Runners, Gravity Loaded, and Nonfire- 808 for ceiling systems up to 4 psf(19.5 kg/m2)of uniform resistance-rated: Cross runners for use to support gravity gravity load.The 730145 main runners are cold-formed from loads only and in non-fire-resistance rated ceiling ASTM A568 steel. The runners have a hot-dipped assemblies are the XL 7325 and XL 7345 series runners galvanized coating and a factory-installed, polyester- listed in Table 3. The suspended ceiling framing system painted steel cap along the entire length of the bottom must be installed in accordance with the 2015, 2012, and flange. The 730145 main runners are used In conjunction 2009 IBC Section 808 for ceiling systems up to 4 psf with XL7325 and XL 7345 cross runners fisted in Table 3 of (19.5 kg/m2)of uniform gravity load. Profiles of the runners this report. Profiles of the runners are shown in Figure 1. are shown in Figure 1. Members are cold-formed from 3.1.4 Cross Runners, Nonfire-resistance-rated: Cross ASTM A568 steel with a hot-dipped galvanized coating and runners for use in nonfire-resistance-rated ceiling a factory-installed, polyester-painted steel cap along the assemblies are the XL6100 series (Interlude), XL6500 entire length of the bottom flange. Table 3 specifies series(Sonata),XL7100 series(Prelude),XLAL7200 series dimensions,lengths,and allowable transverse loads. (Aluminum Prelude),XLSS7200 series(Stainless Prelude), 3.1.8 Materials:Steel runners are cold formed from ASTM XL7300 series (Prelude), XL7500 series (Suprafine), A653 CS Type B steel and have a hot-dipped galvanized XL7600 series (Silhouette), XL76008 series (Silhouette), minimum protective zinc coating of G30,G60, or G90.The EA7900 series(Aluminum 15/16 Inch Clean Room), EA7903 steel runners have a carbon steel composition that conforms series (Aluminum 11/2 inch Clean Room), and ES7900 to ASTM A568 and a zinc protective coating that conforms series(Steel 15/16 Inch Clean Room). to ASTM A653. Aluminum runners are cold-formed from The XL 6100 series, XL6500 series, XL7100 series, XL 3003-H14 and 3105-H24 aluminum,and the stainless steel 7300 series, XL7500 series, XL7600 series and XL76008 runners are cold formed from 300 series stainless steel. series ES7900 series cross runners are cold-formed from 3.2 Hanger Wire: ASTM A568 steel. The cross runners have a hot-dipped Hanger wire for suspended ceilings,framing members, and galvanized coating and a factory-Installed polyester-painted any fixtures must comply with Section 13.5.6 of ASCE 7 and steel cap or aluminum cap along the entire length of the IBC Section 2506.2.1. bottom flange. The XL 6100 XL6500, ES7900 and XL 3.3 BERC Clip: 7600and XL 76008 series have a baked polyester painted coating in addition to the hot-dipped galvanized coating,and The BERC(Beam End Retaining Clip)System is illustrated have no capping on the lower flange. The XLAL 7200, in Figure 3. The BERC dip is used to connect main and EA7900 and EA7903 series runners are cross runners to wall molding at the ceiling perimeter. The cold-formed from 3003-H14 aluminum and have a baked clip is similar to the BERC-2 clip, described below, except polyester painted coating. The XL6500 series, ES7900 the horizontal leg of the BERC dip is shorter than that of the series, EA7900 series and EA7903 series runners have a BERC-2. polyurethane-filled upper bulb in addition to a polyurethane- 3.4 BERC-2 and AL BERC-2 Clips: coated lower flange. The XLSS 7200 runners are cold The BERC-2 and AL BERC-2 clips are illustrated in Figure formedfrom 300 series stainless steel complying with ASTM 2.The dips are used to connect main and cross runners to A480.Table 3 specifies dimensions,lengths,and allowable wall molding at the ceiling perimeter. The BERC-2 clip is transverse loads. manufactured from 0.034-inch-thick (0.864 mm), 3.1.5 Main Runners, Fire-resistance-rated: Main hot-dipped galvanized, cold-rolled steel complying with runners for use in fire-resistance-rated ceiling assemblies ASTM A568. The AL BERC-2 dip is fabricated from are the HD 8201,8300,8301,8500 and 8501 runners listed 0.034-inch-thick (0.864 mm) 3003-H16 or 3105 H16 in Table 2. The 8300 and 8500 runners are classified Aluminum. ESR-1308 I Most Widely Accepted and Trusted Page 3 of 21 3.5 STAC Clip: 4.4.2 Ceiling Framing Systems with BERC, BERC- The Single Tee Adapter Clip(STAC)is illustrated in Figure 2,and AL BERC-2 Clips: 4. The STAC clip is used to connect cross runners to main 4.4.2.1 Alternate Installation with BERC-2 and AL runners in off-module and staggered grid installations. The BERC-2 Clips„for Seismic Design Categories O, E and cross runners must have a minimum steel substrate F: Under this installation, the main runner must be rated thickness of 0.015-inch. The connection capacity between heavy-duty and have a minimum simple span allowable main runner and cross runner exceed 180 lbf(81.5 kg).The uniform load of 16.35 pounds per lineal foot(238 Wm);with STAC clip Is manufadurered from 0.046-inch thick a maximum ceiling weight permitted for systems with (1.17 mm), hot-dipped galvanized, cold-rolled steel BERC-2 clips at 4 pounds per square foot(19.5 kg/m2);with compling with ASTM A568. a maximum ceiling weight permitted for systems with AL BERC-2 clip at 2 pounds per square foot(9.75 kg/m2). With 3.6 Accessories: this installation under Section 4.4.2.1, the main and cross runners must be as described in Table 2 and 3 of this report. Each framing system has accessory items that include support angles and corner caps. Steel for accessory items The BERC-2 and AL BERG-2 clips are used to secure the is manufactured from hot-dipped galvanized, cold-rolled main runners and cross runners to the wall molding, as steel complying with ASTM A568 and ASTM A653. detailed below and shown in Figure 2. A nominally /8-inch (22 mm)wall molding is used in lieu of the 2-inch(51 mm) 3.6.1 TechZone Yoke(TZYK): perimeter supporting closure angle required by Section The TechZone Yoke(TZYK)is illustrated in Figure 5. The 5.2.2 of ASTM E580 and Section 13.5.6.2.2 of ASCE 7-16 TZYK is used in ceiling framing systems with continuous for do 13.5.6.2.2018 IBC ASCE of7 ASCEfor the 2015 for and 20120 IBC and lighting and diffuser configurations; each yoke assembly SeiSection (b) 7-05 for the 2009 IBC]for requires 2 single yokes and when assembled create either mustsmie D prescribed Categoriesthe D,E and leF.The ceilingexc system 4-inch(101.6 mm),6-inch(152.4 mm),or 8-inch(203.2 mm) ofbe as byandapplicable code clips and the widths. The TZYK is manufactured from 0.050-inch thick use of the BERC-2 and AL BERC-2 and the (1.27 mm)hot-dipped galvanized,extruded steel complying 7/8-inch (22 mm)wall molding and elimination of spreader bars. with ASTM A653. The BERC-2 and AL BERC-2 clips are attached to the wall 4.0 DESIGN AND INSTALLATION molding by sliding the locking lances over the hem of the 4.1 General: vertical leg of the wall molding (see Figure 2). The AL BERC-2 clip requires an additional No. 7 by 7/16-inch long The suspended ceiling framing system must be installed in (minimum) self-piercing sheet metal screw connecting the accordance with this report and the manufacturer's AL BERC-2 clip to the wall molding as shown in Figure 2. published installation instructions. The suspended ceiling BERC-2 and AL BERC-2 clips installed on the two adjacent framing system must be installed In accordance with IBC walls where the runners must be fixed (attached wall), are Sections 808, 1613 and 2506.2.1 for ceiling systems up to attached to the runner by a No.7 by'/16-inch long(minimum) 4 psf(19.5 kg/m2). self-piercing sheet metal screw through the fixed hole in the 4.2 Main Runners: clip and the top flange bulb of the runner. BERC-2 and AL BERC-2 clips installed on opposite walls where the runners Main runners must be installed and leveled to within must not be fixed to the clips(unattached walls), the clips 1/4 inch in 10 feet(6.4 mm in 3048 mm),with the supporting must not be mechanically connected to the runner by any wire taut. Vertical support hanger wire must be installed fastener and must allow the terminal runner end to move within 3 inches(51 mm)of the main runner fire expansion 3/4 inch (19.1 mm) towards and away from the wall, and relief.The design loads for main runners must be less than installation of a No. 7 by 7/16-inch long (minimum) self- or equal to the capacities allowed in Table 2 of this report. piercing sheet metal screw through the horizontal slotted Supports for the main runners that consist of vertical hole is optional,as shown in Figure 2. Under the 2018 IBC, hangers,perimeter hangers,and lateral force bracing must as required by Section 13.5.6.2.2 of ASCE 7-16, either be installed in accordance with the applicable code. BERC-2 or AL BERC-2 dips must be screwed to the wall mdding with a total of two(2)screws,and the wall molding 4.3 Cross Runners: must be positively attached to the wall studs or other Main runners, or other cross runners, must support cross supporting structure. runners to within 1/32 inch(0.80 mm)of the required center- BERG-2 and AL BERC-2 clips installed in this manner are to-center spacing. This tolerance must be noncumulative an acceptable means of preventing runners from spreading beyond 12 feet (3658 mm). Intersecting runners must be in lieu of spacer bars(stabilizer bars)required in Section 5 installed to form a right angle to the supporting members. of ASTM E580 for the 2018, 2015 and 2012 IBC (CISCA The maximum design load capacities for cross runners 3-4 for the 2009 IBC). ASTM E580 is referenced in ASCE must be less than or equal to the capacities allowed in Table 7, which is referenced in the 2018, 2015 and 2012 IBC 3 of this report. Section 1613 (CISCA 3-4 is referenced in ASCE 7-05, Section 13.5.6.2.2,which is referenced in 2009 IBC Section 4.4 Seismic Design: 1613). The assemblies described In in this Section 4.4.2.1 4.4.1 Seismic Design Requirements: Seismic design are equivalent to that required by CISCA 3-4 and Section 5 of and installation details of the ceiling systems, excluding ASTM E580. See Figure 2. 730145 main runner, and XL7325 and XL7345 cross A single 1/8-inch-diameter (3.175 mm) steel pop rivet runners, must be in accordance with Section 13.5.6 of complying with Industrial Fastener Institue Standard ASCE 7-16 for the 2018 IBC[ASCE 7-10 for the 2015 and IFI-114 may be used in lieu of BERC-2 and AL BERG-2 2012 IBC and ASCE 7-05 for the 2009 IBC];as referenced perimeter clips to secure the main runners and cross in IBC Section 1613,except as noted in Section 4.4.2 of this runners to the wall molding on two adjacent walls(attached report. Systems classified as intermediate-duty are limited walls). The center of the rivet must be 0.25 inch(6.35 mm) to use in Seismic Design Categories A, B and C. from the edge of the wall angle. See Figure 2. ESR-1308 I Most Widely Accepted and Trusted Page 4 of 21 4.4.2.2 Alternate Installation with BERC-2 and (unattached walls), as detailed in this section and shown in TechZone Yoke (TZYK)for Seismic Design Categories Figure 3. The dip is attached to the wall molding by sliding D, E and F: Under this installation,the 7501 main runner the locking lances over the hem of the vertical leg of the wall must be used,with a maximum ceiling weight permitted for molding; the AL BERC-2 dip also requires an additional systems with BERC-2 clips at 3.35 pounds per square foot No. 7 by 7/16-inch long(minimum)self-piercing sheet metal (16.4 kg/m2), The BERC-2 dips are used to secure the main screw through the dip and into the wall molding.When the runners and cross runners to the wall molding,as detailed runners must be fixed(attached walls)at two adjacent walls, below and shown in Figure 2.A nominally 7/8-inch(22 mm) attach a No.7 by 7/18-inch long self-piercing screw through wall molding is used in lieu of the 2-inch(51 mm)perimeter the fixed hole of a BERC-2 or AL BERC-2 clip and the top supporting closure angle required by Section 5.2.2 of ASTM flange bulb of the runner, or through the fixed hole of a E580 and Section 13.5.6.2.2 of ASCE 7-16 for the 2018 IBC BERC dip and into the web of the runner. BERC-2, AL [ASCE 7-10 for the 2015 and 2012 IBC and Section BERC-2, or BERC clips installed on opposite walls where 13.5.6.2.2 (b)of ASCE 7-05 for the 2009 IBC]for Seismic the runners must not be fixed to the clips(unattached walls), Design Categories D, E and F.The ceiling system must be the clips must not be mechanically connected to the runner as prescribed by the applicable code except for the use of by any fastener and must allow the terminal runner end to the BERC-2 dips and the 7/8-inch(22 mm)wall molding and move 3/8-inch(9.5 mm)towards and away from the wall,and elimination of spreader bars. installation of a No. 7 by 7/16-inch long (minimum) self- The BERC-2 dips are attached to the wall molding by piercing sheet metal screw through the horizontal slotted sliding the locking lances over the hem of the vertical leg of hole is optional,as shown in Figure 2. the wall molding(see Figure 2). BERC-2 clips installed on BERC or BERC-2 or AL BERC-2 clips installed in this the two adjacent walls where the runners must be fixed manner are an acceptable means of preventing runners (attached wall), are attached to the runner by a No. 7 by from spreading, in lieu of spacer bars (stabilizer bars) 7/16-inch long (minimum) self-piercing sheet metal screw required in Section 4 of ASTM E580,which is referenced in through the fixed hole in the clip and the bulb of the runner. Section 13.5.6.2.1 of ASCE 7-16 under the 2018 IBC BERC-2 dips Installed on opposite walls where the runners Section 1613 [ASCE 7-10 under the 2015 and 2012 IBC must not be fixed to the clips (unattached walls), the dips Section 1613; and Section 13.5.6.2.1 and CISCA 0-2 as must not be mechanically fastened to the runner and must referenced in ASCE 7-05 under the 2009 IBC Section 1613). allow the terminal runner end to move 3/4 inch (19.1 mm) Except for the use of the BERC or BERC-2 or AL BERC-2 towards and away from the wall. Installation of a No. 7 by clip as noted above, installation of the ceiling system must 7/16-inch long (minimum) self-piercing sheet metal screw be as prescribed by the applicable code. The maximum through the horizontal slotted hole is optional, as shown in ceiling weight permitted is 2.5 pounds per square foot Figure 2. Under the 2018 IBC, as required by Section (12.2 kg/m2) for ceiling systems using BERC or BERC-2 13.5.6.2.2 of ASCE 7-16,BERC-2 dips must be screwed to clips and 2 psf(9.75 kg/m2)for ceiling systems using the AL the wall molding with a total of two(2)screws,and the wall BERC-2 clip. With this installation, the main and cross molding must be positively attached to the wall studs or runners must be as described in Tables 2 and 3 of this other supporting structure. report, except for CleanRoom AL series (EA7900C, Each TZTK yoke assembly must be suspended from EA7920C, and EA7940C) and CleanRoom Steel series structure with a vertical 12 gauge steel wire through the (ES7901C, ES7920C and ES7940C). center hole of the top of the yoke assembly.Altemativey,the The assemblies described in this Section 4.4.2.3 are yoke assembly can be suspended from two hanger wires equivalent to that required by Section 4 of ASTM E580, secured through the holes at the corners of the yoke which is referenced in Section 13.5.6.2.1 of ASCE 7-16 assembly.The yoke assembly must be attached to the main under 2018 IBC Section 1613[ASCE 7-10 under the 2015 runners and to the cross tees using a single 1/8-inch- and 2012 IBC Section 1613; and Section 13.5.6.2.1 and diameter (3.175 mm) steel pop rivet complying with CISCA 0-2,as referenced in ASCE 7-05 under the 2009 IBC Industrial Fastener Institute Standard IFi-114 at 24 inches Section 1613] A single 1/8-inch-diameter(3.175 mm) steel (609.6 mm)from the perpendicular end of the main runner pop rivet complying with Industrial Fastener Institue and spaced at every 48 inches(1219.2 mm)on center. All Standard IFI-114 may be used in lieu of BERC-2,AL BERC- lighting fixtures must be Installed in accordance with Section 2,and BERC perimeter dips to secure the main runners and 5.3 of ASTM E580. cross runners to the wall molding on two adjacent walls In lieu of splay wire bracing in accordance with Section 5.2.8 (attached walls). The center of the rivet must be 0.25 inch of ASTM E580, rigid bracing members composed of (6.35 mm)from the edge of the wall angle. See Figures 2 21/2-inch (63.5 mm) wide by 25 gage steel studs must be and 3. attached to the web of the main runner using self-tapping 4.5 Lighting Fixtures: screws. The two rigid bracing members splayed 90 degres Lighting fixtures must be installed in accordance with from each other at an angle of 45 degrees from the plan of the ceiling. The location and spacing of the rigid bracing Section 13.5.6 of ASCE 7-16 and ASCE 7-10. Lighting members must comply with Section 5.2.8 of ASTM E580. In fixtures may also be attached to the grid with clips complying addition to the rigid bracing members, a compression post with the ICC-ES Acceptance Criteria for Attachment De composed of a 21/2-inch(63.5 mm)wide 25 gage steel stud vices for Recessed Lighting Fixtures (Luminaires) in connected to the main runner. The length of the bracing Suspended Ceiling Systems (AC184). The lighting fixtures members must be designed by a registered design may also be attached to the framing members with sheet professional. metal screws having a minimum allowable shear strength of 314 lbf(1395 N)and minimum allowable tension strength of 4.4.2.3 Alternate Installation with BERC, BERC-land 137 lbf (609.6 N) for a No. 20/20 gage metal-to-metal AL BERC-2 Clips, for Seismic Design Category C: connection. Terminal ends of the runners are secured by attaching either 4.6 Partitions: the BERC, BERC-2 or AL BERC-2 clip to the wall molding and attaching the runners to the clip.The runners have zero Partitions must be laterally supported as required by Section clearance at the perimeter on two adjacent walls(attached 13.5.8 of ASCE 7, as referenced by the applicable IBC walls)and 3/8-inch(9.5 mm)clearance on the opposite walls Section 1613. ESR-1308 I Most Widely Accepted and Trusted Page 5 of 21 4.7 Two-hour Flre-resistance-rated Floor-ceiling (3657.6 mm).Intersecting runners must be Installed to form Assembly: a right angle to the supporting members. The design loads The floor-ceiling assembly described in Section 4.7 has a for cross runners must be less than or equal to the two-hour fire-resistance rating(refer to Figure 7 for details): capacities shown in Table 3. A cross runner that supports another cross member must have a minimum uniformly 4.7.1 Structural Beams: The structural floor beams distributed load capacity of 12 pounds per linear foot supporting the floor-ceiling assembly are minimum W8x15, (175 N/m). or an equivalent-sized steel beam having a minimum weight-to-heated-perimeter ratio,W/D,of 0.54. 4.7.5.3 Hanger Wire:The suspended ceiling is supported by No. 12 SWG [0.105 inch (2.7 mm) in diameter] In accordance with Section 704.3 of the 2015, 2012,and galvanized steel wire that is attached to the concrete slab 2009 IBC, structural steel floor beams need not be through the steel floor units, before concrete placement, or individually fire-protected when the suspended ceiling forms attached to hanger clips. The hanger clips are minimum the protective membrane for the fire-resistance-rated 0.045-inch-thick(1.14 mm),2-inch-wide(51 mm),31/2-Inch- assembly. However, structural floor beams must be long(90 mm),galvanized steel dips that are hooked at one individually protected,on all sides for the full length with end, for attachment over the male leg of steel floor units, materials having the required fire-resistance rating, when and spaced as required for hanger wire attachment. they support directly applied loads from a floor and roof or more than one floor, or where the required fire-resistance Hanger wires are spaced a maximum of 48 inches rating of such members is greater than two hours. (1219 mm)on center or must be located at every other main 4.7.2 Floor Joists: Floor 'ousts are minimum 10Ki steel runner/cross-tee intersection, whichever dimension is less 1 along main runners. Hanger wire must be located at all four bar joists, spaced a maximum of 24 inches (610 mm)on corners of light fixtures, at mid-span of cross toes next to center.Each joist must be welded to end supports,and must 4-and 5-foot-long(1219 and 1524 mm)light fixtures and air have 1/2-inch-diameter (12.7 mm) steel bar bridging duct outlets,and next to each main runner splice.Additional members welded to top and bottom chords of each joist at hanger wires are required at the mid-span of those cross midspan. tees running parallel and nearest to the walls and those near 4.7.3 Steel-floor Decking: The concrete deck is the end of cut cross tees longer than 2 feet(610 mm)that either supported by minimum No. 22 gage [0.0299 inch abut walls. (0.759 rum)] galvanized steel deck panels with 118/32-inch- 4.7.6 Acoustical Material:Acoustical lay-in ceiling panels deep(32.5 mm)flutes spaced 6 inches(152 mm)on center, used with the suspended ceiling system are the nominal or is supported by minimum No. 20 gage [0.0359 inch panel sizes and types shown in Table 1. Panels are (0.91 mm)] galvanized steel cellular panels having nominally 543 inch (15.9 mm) or 3/4 inch (19.1 mm) thick. 3-inch-deep(76 mm)flutes. Border panels are supported at walls by 24 MSG painted When a blend of fluted and cellular steel deck panels is steel channels, 1 inch (25 mm) deep, with a used, the concrete topping thickness is measured from the 2-inch (23.8 mm) bottom flange. Optional support method top plane of the cellular deck panels.The steel deck panels consists of BERC-2 clip at wall attached to must be welded to supports at 12 inches (305 mm) on 15/16 inch x 15/16 inch No,24 MSG painted steel channels. center. Adjacent deck panels must be button-punched or 4.7.7 Hold-down Clips: Hold-down clips, produced from welded together at 36 inches (914 mm) on center at side No. 24 gage spring steel, must be used for ceiling panels joints. weighing less than one pound per square foot. When the Where fluted and cellular floor deck panels are installed ceiling is composed of nominally 24-by-24-inch (610 by end-to-end,galvanized steel angles must be tack-welded to 610 mm),24-by-36-inch(610 by 914 mm),or 30-by-30-inch the cellular floor deck panels in such a manner as to cover (762 by 762 mm)lay-in panels,one clip is placed over bulbs the cells. of cross tees near cross tee midpoints.When the ceiling is 4.7.4 Concrete Floor: The concrete floor must be a composed of 20-by-60 inch (508 by 1524mm), 36-by- 36-inch(914 by 914 mm),24-by-48-inch(610 by 1219 rum), minimum of 21/2 inches(63.5 mm)thick,measured from the top of the metal deck panels, and normal-weight concrete 152430-b orch 48-by-(76 by 1524 mm),9 36-by-60-inch inch panels,(91 by with carbonate or siliceous aggregates. The concrete must clips524 mm)or er bulbs 48-inchl (each mm)lay-in two have a minimum density of 150±3 pcf(2400±48 kg/m3), u are placed over leg of cross tee neartcross tee and a minimum compressive strength of 3,000 psi quarter-points. One leg of each tees dip is cut off long (20.7 MPa).The middle of the slab must be reinforced with placement is over bulbs of cross adjacent to the long 6x6—W1.4xW1.4 welded wire fabric. side of light fixtures. 4.7.5 Suspended Ceiling Members: 4.7.8 Recessed Ught Fixtures: Fluorescent-lamp-type, steel housing fixtures can be used in the fire-resistance- 4.7.5.1 Maln Runners: Main runners are either the 8300, rated assembly, provided the fixtures measure 1 by 4 feet 8301 or HD 8201. The main runners are 12 feet (305 by 1219 mm),2 by 2 feet(610 by 610 mm),2 by 4 feet (3657.6 mm) long and spaced a maximum of 4 feet (610 by 1219 mm),20 by 48 inches(508 by 1219 mm)or 20 (1219.2 mm)on center. The design loads for main runners by 60 inches (508 by 1524 mm). The nominally must be less than or equal to the capacities shown in Table 1-by-4-foot(305 by 1219 mm),2-by-2-foot(610 by 610 mm) 2. Vertical hangers, perimeter hangers, and lateral-force and 2-by-4-foot (610 by 1219 mm) fixtures may include bracing for the main runners are installed in accordance with vented sides for air boots and vented tops for air-return the code. The distance from the bottom side of the floor purposes.Linear air diffusers and linear air returns must be decking to the bottom side of the main runners is a minimum used with nominally 20-by-48-inch (508 by 1219 mm) of 193/4 inches(502 mm). fixtures.When nominally 20-by-60-inch(508 by 1524 mm) 4.7.5.2 Cross Runners: Cross runners are either the XL fixtures are used, fixture stabilizers are used to 8200 series (Prelude Plus Fire Guard) or XL 8300 series supplement the hanger wires occurring at the mid span of (Prelude Fire Guard). Main runners must be located within the 5-foot-long(1524 mm)cross tees. 1/32 inch(0.79 mm)of the required center distances,and this When nominally 1-by-4-foot(305 by 1219 mm)fixtures are tolerance must be noncumulative beyond 12 feet used,the aggregate number of fixtures must not exceed four ESR-1308 I Most Widely Accepted and Trusted Page 6 of 21 per 100 square feet(9.3 m2)of ceiling area.When nominally Where special inspections are required by the building 2-by-2-foot (610 by 610 mm) fixtures are used, the official,a statement of special inspection must be provided aggregate number of fixtures must not exceed five per as required by 2018, 2015 and 2012 IBC Section 1704.3 100 square feet (9.3 m2) of ceiling area. When nominally (Sections 1705.2 and 1705.3 for the 2009 IBC). 2-by-4-foot (610 by 1219 mm), 20-by-48-inch (508 by 5 CONDITIONS OF USE 1219 mm),or 20-by-60-inch(508 by 1524 mm)fixtures are used, the aggregate number of fixtures must not exceed The suspended ceiling systems described in this report three per 100 square feet (9.3 m2) of ceiling area. The comply with,or are suitable alternatives to what is specified fixtures must be wired in conformance with an approved in,those codes listed in Section 1.0 of this report,subject to electrical code. the following conditions: The recessed light fixture must be protected on the topside 5.1 The ceiling suspension main runners, cross runners, with acoustical ceiling tile panel material having a minimum BERC, BERC-2,AL BERC-2, STAC and XTAC clips, thickness of 5/e inch (15.9 mm). The panels are cut into and accessories must be fabricated and installed in pieces to form a five-sided enclosure which is rectangular or accordance with this report and the manufacturer's. trapezoidal in cross section, depending upon fixture type, published installation instructions. In the event of a and which is approximately 1/2 inch (12.7 mm) longer and conflict between the manufacturer's installation wider than the fixture,with sufficient depth to provide at least instructions and this report,this report governs. 1 inch (12.7 mm)of clearance between the fixture and the enclosure. The pieces are held together with 8d nails. 5.2 Design loads and spans of main and cross runners Spacers provide the 11/4-inch (31.7 mm)clearances when must comply with Tables 2 and 3 of this report. placed on top of fixtures located away from the ballasts. 5.3 Suspended ceiling systems must be designed and When no air-handling or air-return fixtures are used, a installed In accordance with ASCE 7 Section 13.5.6 as maximum 1'/4-inch (31.7 mm) separation must be referenced by the applicable IBC Section 1613. The maintained between the long fixture protection sldepieces documents must be prepared by a registered design and the top piece. When air supply light fixtures with air proffmsional where required by statutes of the boots are used,fixtures and air boots must be fully enclosed jurisdiction in which the project is to be constructed. except for the nominally 28-square-inch (18 064 mm2) opening needed for the connection to air-supply ducts. 5.4 Special inspections must be provided in accordance 4.7.9 Air Duct: Air ducts are permitted in the assembly with Section 4.9 of this report. provided the ducts are constructed of minimum No.22 MSG 5.5 For Seismic Design Category C, D, E or F, a quality galvanized steel and aggregate duct opening area is less assurance plan complying with IBC Chapter 17, than or equal to 113 square Inches (72 903 mm2) per inducing 2015 and 2012 IBC Section 1704.3 (2009 100 square feet (9.2 m2)of ceiling area. The maximum air IBC Sections 1705.2 and 1705.3)must be submitted to duct-opening dimension is 12 inches(305 mm). the code official. 4.8 8500 (Prelude SupraFine Fire Guard) Series One- 5.6 The ceiling framing systems must not be used to hour Fire-resistance-rated Roof-ceiling System: provide lateral support for walls or partitions,except as This exposed grid system consists of the 8500 series main provided for in ASCE 7,Section 13.5.8.1 as referenced runners and the XL 8520 or XL 8540 cross runners,and is in the applicable IBC Section 1613. part of a one-hour fire-resistance-rated floor-ceiling system. 5.7 The ceiling systems must be braced to resist seismic The rating applies to restrained and unrestrained forces as determined from Section 1613 of the IBC. assemblies as described in ASTM E119. See Figure 6 for 5.8 The systems are limited to ceilings not considered assembly details. General requirements in 2015 and 2012 accessible in accordance with Item 28 of 2018, 2015 IBC Section 711 and 2009 IBC Section 712 must be and 2012 IBC Table 1607.1 (Item 31 of 20091 BC Table observed. 1607.1). 4.9 Special Inspection: 5.9 The supporting construction for the ceiling system has Where special inspections are required by the building not been evaluated and Is outside the scope of this official, the suspended ceilings in Seismic Design report.The code official must approve the floor or roof Categories C,D,E and F shall be subject to periodic special construction supporting the suspended ceiling system. inspections during the installation of the suspended ceiling systems and their anchorage in accordance with the 5.10 The ceiling systems recognized in this report have following requirements: been evaluated for use in interior applications. For exterior ceiling systems must be designed for wind • For installations in accordance with Section 4.4.2 of this loads and with due consideration of atmospheric report,special inspection must be conducted as required conditions. by the building official during enforcement of the 2018 and 2015 IBC Sections 1704.5, 1705.1.1 and 1705.13.2 5.11 Lay-in ceiling panels must be justified to the [2012 IBC Sections, 1705.1.1, 1705.11.4 and Item 3 of satisfaction of the code official as complying with the Section 1705.12;and 2009 IBC Section 1704.15, Item 3 interior finish requirements of Chapter 8 of the of Section 1708.1,and 1708.4],as applicable. applicable code. • For Installation in accordance with Section 4.4.1 of this 5.12 The electrical safety of the EAC main runners is report, special inspection must must be in compliance outside the scope of this report. EAC main runners with the following: Section 13.5.6.2.2(h)of ASCE 7-05, must be installed in accordance with the applicable and 2009 IBC Section 1705.3.4,Item 3 for the 2009 IBC; provisions of the National Electrical Code. Section 13.5.6.2.2(h)of ASCE 7-05,as applicable. 5.13 Suspended ceiling system with 730145 main runner, • The special inspector must verify that the ceiling framing and XL7325 and XL7345 cross runners have only been systems are as described in this report,and comply with evaluated for gravity loads only. Seismic design is the this report and the approved construction documents. outside the scope of this report ESR-1308 I Most Widely Accepted and Trusted Page 7 of 21 6.0 EVIDENCE SUBMITTED designations specifying gage of steel, depth of section 6.1 Data in accordance with the ICC-ES Acceptance and length, and the evaluation report number Criteria for Suspended Ceiling Framing Systems (ESR-1308). (AC368),dated November 2019. 7.2 The report holder's contact information is the following: 6.2 Reports of fire-resistance tests in accordance with WORTHINGTON ARMSTRONG VENTURE(WAVE) ASTM E119. 101 LINDENWOOD DRIVE,SUITE 350 6.3 Reports of comparative seismic qualification tests in MALVERN,PENNSYLVANIA 19355 accordance with the ICC-ES Acceptance Criteria for (610)722-1218 Seismic Certification by Shake-table Testing of www.armstronq.com Nonstructural Components (AC156), dated October jrameent armstrongceilings.com 2010(editorially revised September 2019). 7.3 The Additional tastee's contact information is the 7.0 IDENTIFICATION following: 7.1 Cartons of framing members,clips and accessories are ARMSTRONG WORLD INDUSTRIES,INC. identified with the name and address of Armstrong POST OFFICE BOX 3001 World Industries, Inc.; the acronym "WAVE": number LANCASTER, PENNSYLVANIA 17604 TABLE 1—ACOUSTICAL MATERIALS ACOUSTICAL PANEL SIZE(inches) ACOUSTICAL MATERIAL TYPE' STEEL FLOOR DECK PANEL TYPE' 0 by 60 P(S OR P)OR PC(S) F,CorB 20 by 60 P{S OR P)OR PC(S) For 81 24 by 24 BF(S) F,C or B 24 by 24 BF(S) F 24 by 24 or 36 P(S) F,CorB 24 by 24 or 36 PC(S) C or B 24 by 24 or 36 P(S) F 24 by 48 or 60 P(S OR P)OR PC(S) F,C or B 24 by 48 or 60 P(S OR P)OR PC(S) F or B1 30 by 30 P(S) F,CorB 30 by 30 PC(S) C or B 30 by 30 P(S) F 30 by 60 P(S)OR PC(S) F,CorB 36 by 36 PC(S) F,CorB 36 by 36 PC(S) F or B1 36 by 60 PC(S) F,C or B 48 by 48 PC(S) F,CorB For SI:1 inch=25.4 mm. '(S)=surface perforations,(P)=through perforations. •"(F)=all fluted steel deck panels,(C)=all cellular steel floor deck panels,(B)=any blend of fluted and cellular floor deck panels,(B,)=blend of one cellular floor deck panels and one or more fluted deck panels. - ESR-1308 I Most Widely Accepted and Trusted Page 8 of 21 TABLE 2-DIMENSIONS AND ALLOWABLE LOADS FOR MAIN RUNNERS CATALOG NOTE TYPE LENGTH METAL MAXIMUM ALLOWABLE NUMBER (SEE FIGURE 1) (inc THICKNESS SPAN LOADS hes) (inch) (feet) Simple Span Uniform Load (Ib.Hfn_ft.) 6100 1 M 144 0.013 4 12.6 6101 1 M 144 0.019 4 16.79 6121A 1 M 144 0.019 4 16.79 6127A 1 M 120 0.019 4 16.79 6132 1 M 132 0.019 4 16.79 6195A 1 M 126 0.019 4 16.79 65008 5 P 144 0.015 4 15.92 6501 1,5 P 144 0.018 4 19.42 Al 7200 1 B 144 0.021 3 13.47 SS 7200 3 B 144 0.015 4 12.23 7300 1 A 144 0.010 4 13.5 7301 1 A 144 0.015 4 16.73 730106 1,8 S 72 0.017 4 17.35 730145 1,7 U 144 0.0195 4 40.16 7302 1 A 120 0.010 4 13.5 7305 1 A 140 0.010 4 13.5 7306 1 A 132 0.015 4 17.25 7307 1 A 126 0.015 4 17.25 7500 1 H 144 0.013 4 1275 7501 1 H 144 0.018 4 16.86 7502 1 H 120 0.013 4 12.38 7504 1 H 120 0.018 4 16.28 7507 1 H 144 0.018 4 16.28 DC730112 1.8 S 144 0.017 4 17.35 DC730110 1,8 S 120 0.017 4 17.35 DC730108 1.8 S 96 0.017 4 17.35 DC730106 1.8 S 72 0.017 4 17.35 7508 1 H 132 0.018 4 16.28 7509 1 H 126 0.018 4 16.28 DC750112 1 N 144 0.019 4 16.83 00750110 1 N 120 0.019 4 18.83 DC750108 1 N 96 0.019 4 16.83 DC750106 1 N 72 0.019 4 16.83 750106 1 N 72 0.019 4 16.83 7800 1 K 144 0.013 4 13.10 76008 1 L 144 0.013 4 13.10 7601 1 K 144 0.017 4 16.35 76018 1 L 144 0.017 4 16.35 7602 1 K 120 0.017 4 13.10 76028 1 L 120 0.013 4 13.10 7803 1 K 144 0.013 4 12.28 76038 1 K 144 0.013 4 12.28 7604 1 K 120 0.017 4 16.35 76048 1 L . 120 0.017 4 16.35 7605 1 K 120 0.017 4 16.35 76058 1 L 120 0.017 4 16.35 7606 1 K 120 0.013 4 13.07 76068 1 L 120 0.013 4 13.07 7607 1 K 120 0.013 4 12.8 7612 1 K 144 0.018 4 16.48 76128 1 K 144 0.018 4 16.48 DC780112 1 0 144 0.015 4 18.44 DC760110 1 0 120 0.015 4 16.44 DC760108 1 0 96 0.015 4 16.44 DC760106 1 0 72 0.015 4 16.44 760106 1 0 72 0.015 4 16.44 EA7900 5 Q 144 0.026 4 12.26 EA7900C 6,8 T 144 0.021 4 14.09 EA7903 5 R 144 0.022 4 16.74 ES7901 5 Q 144 0.015 4 18.33 ES7901C 6,8 V 144 0.017 4 20.39 HD 8201 1,HD A 144 0.015 4 16.73 8300 1 A 144 0.010 4 13.5 8301 1 A 144 0.015 4 16.73 8500 1 H 144 0.013 4 13.31 8501 1 H 144 0.018 4 16.86 For Si:1 inch=25.4 mm,1 foot=304.8 mm,1 Ib./lin.ft.=14.6 N/m,1 lb.=4.44 N. NOTES: 1 = Single stitched web 2 = Double stitched web 3 = Available stitched or unstitched 4 = Hanger wire support at mid-span 5 = Polyurethane filled upper bulb/polyurethane coated lower flange 6 = integral PVC gasket. 7 = Limited to gravity usage.Seismic design is outside the scope of evaluation. 8 = Lateral support/bracing is required at 24 Inches on center. HD = Hot-dipped galvanized finish ESR-1308 I Most Widely Accepted and Trusted Page 9 of 21 TABLE 3-DIMENSIONS AND ALLOWABLE LOADS FOR CROSS RUNNERS CATALOG NOTE TYPE LENGTH METAL MAXIMUM SIMPLE SPAN NUMBER (Inches) THICKNESS SPAN UNIFORM (Inch) (feet) LOAD (IbJIIn.ft.) 6100 Series XL 6104 2 M 4 0.013 0.3 66.89 XL 6106 2 M 6 0.013 0.5 66.89 XL 6110 2 M 12 0.013 1 66.89 XL 6161 2 M 21 0.013 1.75 66.89 XL 6120 2 M 24 0.013 2 66.89 XL 6167 2 M 27 0.013 2.25 49.32 XL 6170 2 M 30 0.013 2.5 38.8 XL 6162 2 M 42 0.013 3.5 20 XL 6140 2 M 48 0.013 4 12.6 XL 6164 2 M 54 0.013 4.5 9.2 XL 6150 2 M 60 0.013 5 5.8 XL 6190 2,4 M 72 0.013 4 12.6 XL 6180 2,4 M 96 0.013 4 12.6 6500 Series XL6521 5 P 24 0.014 2 42.00 XL6541 5 P 48 0.014 4 15.88 7100 Series XL 7128 1 E 24 0.010 2 33 XL7148 1 E 48 0.010 4 6 AL 7200 Series XLAL7220 2 B 24 0.021 2 44.45 XLAL7240 2 B 48 0.021 4 6.33 SS 7200 Series XLSS7220 3 B 24 0.015 2 61.66 XLSS7240 3 B 48 0.015 4 10.4 7300 Series XL 7304 2 D 4 0.009 0.3 36.00 XL 7306 2 D 6 0.009 0.5 36.00 XL 7318 2 D 12 0.009 1 36.00 XL 7398 2 D 18 0.009 1.5 36.00 XL 7368 2 D 20 0.009 1.67 36.00 XL 7328 2 D 24 0.009 2 36.00 XL 7320 2 A 24 0.011 2 61.33 XL 7325 2,7 U 24 0.0195 2 46.72 XL 7378 2 D 30 0.009 2.5 16.54 XL 7330 2 D 36 0.010 3 20.83 XL 7348 2 D 48 0.009 4 6.78 XL 7345 2,7 U 48 0.0195 2 46.72 XL 7342 2 C 48 0.009 4 7.80 XL 7340 2 A 48 0.010 4 12.25 XL 7341 2 A 48 0.015 4 16.89 XL 7357 2 A 60 0.015 5 7.61 XL 7358 2 A 60 0.015 5 7.61 XL 7390 2 A 72 0.010 6 3.3 XL 7390 2,4 A 48 0.010 4 12.24 XL 7380 2 A 96 0.010 8 1.57 XL 7380 2,4 A 96 0.010 4 12.12 7500 Series XL 7504 1 H 4 0.010 0.3 51.83 XL 7506 1 H 6 0.010 0.5 51.83 XL 7510 1 H 12 0.010 1 51.83 XL 7561 1 H 21 0.010 1.75 51.83 XL 7560 1 H 20 0.010 1.67 51.83 XL 7520 1 H 24 0.010 2 51.83 XL 7567 1 H 27 0.010 2.25 28.67 XL 7570 1 H 30 0.010 2.5 28.67 XL 7530 1 H 36 0.010 3 21.03 XL 7562 1 H 42 0.010 3.5 12.67 XL 7540 1 H 48 0.010 4 10.34 XL 7541 1 H 48 0.013 4 12.73 XL 7549 1 H 48 0.018 4 16.42 XL 7564 1 H 54 0.010 4.5 6.72 XL 7558 1 H 60 0.013 5 5.8 XL 7590 1,4 H 72 0.013 4 12.73 XL 7580 1,4 H 96 0.013 4 12.73 For SI: 1 inch=25.4 mm,1 foot=304,8 mm,1 Ibulin.ft...14.6 Nlm,1 lb.=4.44 N. ESR-1308 I Most Widely Accepted and Trusted Page 10 of 21 TABLE 3-DIMENSIONS AND ALLOWABLE LOADS FOR CROSS RUNNERS(Continued) CATALOG NOTE TYPE LENGTH METAL MAXIMUM SIMPLE NUMBER (Inches) THICKNESS SPAN SPAN (inch) (feet) UNIFORM LOAD (lbJlin.ft.) 7600 Series • XL 7804 1 I 4 0.015 0.3 71.66 XL 7606 1 I 6 0.015 0.5 71.66 XL 7610 1 I 12 0.015 1 71.66 XL 7660 1 I 20 0.015 1.67 71.66 XL 7620 1 I 24 0.015 2 71.66 XL 7670 1 I 30 0.015 2.5 39.86 XL 7640 1 I 48 0.015 4 13.53 XL 7646 1 I 48 0.015 4 13.21 XL 7645 1 I 48 0.015 4 12.85 XL 7650 1 I 60 0.015 5 6.09 XL 7655 1 I 60 0.015 5 5.71 XL 7657 1 I 60 0.015 5 5.90 XL 7690 1,4 K 72 0.013 4 12.59 XL 7680 1,4 K 96 0.013 4 12.59 76008 Series XL76108 1 J 12 0.015 1 69.69 XL 76608 1 J 20 0.015 1.67 69.69 XL 76208 1 J 24 0.015 2 69.69 XL 76708 1 J 30 0.015 2.5 47.76 XL 76408 1 J 48 0.015 4 14.11 XL 76468 1 J 48 0.015 4 13.01 XL 76458 1 J 48 0.015 4 12.6 XL 76508 1 J 60 0.015 5 9 XL 76558 1 J 60 0.015 5 7 XL 76578 1 J 60 0.015 5 7 XL 76908 1,4 L 72 0.013 4 12.6 XL 76808 1,4 L 96 0.013 4 12.6 EA7900 Series EA 7920 5 Q 24 0.026 2 66.62 EA 7920C 6 T 24 0.021 2 41.92 EA 7940 5 Q 48 0.026 4 15.32 EA 7940C 6,8 T 48 0.021 4 12.67 EA7903 Series EA 7927 5 R 24 0.022 2 60.55 EA 7947 5 R 48 0.022 4 17.66 ES7901 Series ES 7920 5 Q 24 0.015 2 60.83 ES 7920C 6 V 24 0.017 2 89.53 ES 7940 5 Q 48 0.015 4 16.83 ES 7940C 6.8 V 48 0.017 4 17.26 XL8200 Series XL 8223 2,HD B 24 0.013 2 38.63 XL 8240 2,HD B 48 0.013 4 12.75 8300 Series XL 8313 2 D 12 0.009 1 45.4 XL 8323 2 D 24 0.009 2 40.45 XL 8320 2 A 24 0.011 2 61.33 XL 8378 2 A 30 0.011 2.5 20.84 XL 8330 2 A 36 0.011 3 23.11 XL 8340 2 A 48 0.011 4 12.25 XL 8341 2 A 48 0.015 4 16.89 XL 8357 2 A 60 0.015 5 7.47 XL 8358 2 A 60 0.015 5 7.53 8500 Series XL 8520 1 H 24 0.013 2 58.5 XL 8540 1 H 48 0.013 4 12.73 For SI: 1 inch=25.4 mm,1 fool=304.8 mm,1 ib./lin.ft.=14.6 N/m,1 lb.=4.44 N. NOTES: 1 = Single stitched web 2 = Double stitched web 3 = Available stitched or unstitched 4 = Hanger wire support at mldspan 5 = Polyurethane filed upper bulb/polyurethane coated lower flange 6 = integral PVC Gasket 7 = Limited to gravity usage.Seismic design is outside the scope of evaluation. 8 = Lateral support/bracing is required at 24 inches on center. HD = Hot-dipped galvanized finish ESR-1308 I Most Widely Accepted and Trusted Page 11 of 21 1 4 b4ii 37 90° 1ti 1R 12 1 • . I .I I: �"1 I 1 1. T I E A TY EB IEC 3 1 32 11 (�4 �4 I. - 64 9 1 32 1I T- 1g 1lib 1a [---16---1 r 1 —d 1---g—I TYPE D TYPE E TYPE F a 1-- 13 �Z 32 III 1\` 90° 142f4 13164 90° 14 12 [6464 i • - bz 1---g—I I`r—I 4 16' TYPE G TYPE H TYPE I FIGURE 1—RUNNER PROFILES ESR-1308 I Most Widely Accepted and Trusted Page 12 of 21 1 4 1 - 14r I 1 /‘...,,,.___ go, , -111 17 1i 111 ' L/ t o i 17 # r" l 1 r tad l i I I I k (-- r 9 TYPE J TYPE K TYPE L 1 --1i1-- i 1 17 E 1 1 I, htl Ft4 t1 1 -- ; _ -� j ib� 16 _7_..... t, TYPE? \I TYPE N TYPF c) I0 ) . )� 9 16 TYPE P TYPE Q TYPE R FIGURE 1—RUNNER PROFILES(Continued) ESR-1308 I Most Widely Accepted and Trusted Page 13 of 21 ) r E �I:o� 64 Mi 1 f 0 1 i ( 90° ,iiip 3i 25 1 f_._, 1 2112 $ '-4 lI6 Hi r _ 41 1 --- � 16-- 6--I TYPES TYPE T TYPE U 1 4 6, III 1E C" 6-I TYPE V FIGURE 1—RUNNER PROFILES(Continued) A A ESR-1308 I Most Misty Accepted and"Misted Page 14 of 21 -i . N... i` A . ...... .... ,........,,,... ,„,....... .........., ...,..... ...„...... .....„ ...s. „., ., ..„.., / . ..., -,.... ...,....,... MA f' - ( .. .,....-". \\0 N, .•..., '...„'.... ''''''`,„,...•„.:^s.2.,„,s'ili ,,,,,, 43, ,,„ i \ ' N. • '.....„'Y , ECK 2 EEPC 2 OP 1 INN TIGHT VALI, . CLEARANCE WALL TIGHT VALL ME TALLATMN IHETAILA T ION INSTALL ATICRI (Ai TArtiF D V.AE I) - il/HAT TACK D vALLf (ATTACHED %ALL) -\ , ...,— Ct , .__,,..,........ ,,,,.., atr-vm, iSZeiiregtrirltritilVs , - RUASIILR4 JERC Z .,..., ....„,7 14.l.R01414 IOC 2 ;lull wAL "* L 141TALIATION; ". itcuu.ATICH ,,,* _....e."-- t AT tt1U,ED WALL> ../ „,.. 4tt0,1 SACtiLLI VA4.1.) ..- 7 .,,,7 . 0,0.1111,11, .7'..'. 0 0 0,.0., ...._ , -• .7.14,,,, . ., •-,,,,,,,,,,,,,, ,..-' ..- ^-.... ... -..., , ., .-.1.,-- .. alit.IN.MMDART ''',„ .4 WS}TE.ALLMOR141 t. Et RCZ RECAARI: `,„„ •,E riEffa PIAMES - .0 L an I ttrRfAS., SCREW ',... ! O $W., CLIP A0AD WW.nt.W41.011,6 .„,„. ASOITIEtWit. SCREW tIgiAiliCAN CLIP PO FIGURE 2—BERC-2 AND AL BERC-2 CLIPS 1 ESR-1308 I Most Widely Accepted and Trusted Page 15 of 21 A r �O� /'f � ,,'' fi' pi 011110 ./'l ,.‹,-A,''''., ( tfr,-,,. ,, ,--.,.6.„...„„ N BERC PERC -- OPTION C_EARANCE WALL TIGHT WALL TIGHT WALL IN3TALLAT10t' 1NSTALLA"ION INSTALLATION (UNATTACHED WALL) A"TACHED WALL) (ATTACHED WALL) , LI Ai 0 0,, ,,, Efi 0 C) -- - O G7 O O 0C O O\i 1. POP PI'.(T =KV UGHIDO TIRDP MAIN OI.FNA vLP KitalfTM;smut TIN no4 vALL KLII/C. FIGURE 3—BERC CLIP ESR-1308 I Most Widely Accepted and Trusted Page 16 of 21 FIGURE 4—SINGLE TEE ADAPTER CLIP(STAC) TechZone Yoke(TZYK) • i• convere«nce avow totes • O O o 0 . 0 a Conwnwxe r*Nocor %.ae hates C ' Mart beam 4.25 MIN txatng tab 6.25(SHOWN) ,11 8.25 MAX Insert ovals n,n w.rcto Mar Dram rout 77' aborr ar rari tab C 1� pdol elate Man!tram plot t«da 1, ® MIN a (2) Ices reQ itrrd per 3sseIntV a c 111 6.02 2SHOWN .10 8.02 MAX — FIGURE 5—TECHZONE YOKE(TZYK) ESR-1308 I Most Widely Accepted and Trusted Page 17 of 21 0 0 0 0 0 0 1 r t 1 r rrffyyl'-yt 4rWJM1:16tItu:f Were+M,••• Nt4t»+ta,aadt(7p1T IR.+.lyt,fCwi-lMCT/ifMU1J*+t.Yik:M-K""W+.fA.L tJI'SATJ't4(:{:{J/.":. t+a"O�- 1111111. MI — MI 1111111 -\\N\ cs/fl ° p • fD C} 4,1 • / t 1 rr Y V/ For SI: 1 inch=25.4 mm. 1 foot=304.8 mm,1 psf=4.88 kg/m2,1 gallon=3.81 L, 1 sq.ft =0.0929 m2,1 psi=6.89 kPa, 1 ibm=0.45 kg,1 sq.in.=645.16 mm2. 1. Roof Covering:Roof covering consisting of hot-mopped or cold application materials compatible with insulation(s)described in Item 2 that provide Class A.B or C coverings. 2. Roof Insulation—Mineral and Fiber Boards:The boards must comply with ASTM C612,Type 1A or 1B;24-by-48-inch minimum size, maximum size 48 by 96 inches,to be applied in six layers.Boards to be installed perpendicular to gypsum wallboard direction,with end joints staggered 2 feet in adjacent rows.Each layer of board must be offset,in both directions,from layer below a minimum of 12 inches in order to lap all joints.Minimum board thickness is 1 inch(No limit on maximum overall thickness.) 3. Sheathing Material(Optional):Vinyl film vapor barrier,applied with adhesive to the gypsum wallboard.Adjacent sheets overlapped 2 inches 4. Gypsum Sheathing:Water-resistant core gypsum sheathing complying with ASTM C79.Supplied in sheets nominally 2 by 4 feet to 4 by 12 feet,by nominal inch thick.Minimum weight is 2.0 psf.Applied perpendicular to the steel roof deck direction with adhesive,or laid loosely.End joints to occur over crests of steel roof deck,with end joints staggered 2 feet in adjacent rows. 5. Steel Roof Deck:Minimum 0.019-inch-thick(26 gage),minimum 1-inch-deep,minimum 25-inch-wide,painted or galvanized,fluted steel deck.Flutes must be approximately 4 inches on center.crests approximately 2'/s inches wide.As an alternate,1'/,-inch-deep,minimum 18-inch-wide fluted galvanized steel deck is permitted.Minimum 0,029-inch-thick(22 gage)flutes must be 6 inches on center,crest width ranging from 31/2 to 5 inches.Deck must be welded to supports with welding washers spaced 12 inches on center.Side lap joints of adjacent units welded or secured together with No. 12 by'l2-inch self-drilling,self-tapping steel screws midway between steel joists. 6. Fasteners: A. Adhesive(Optional):BMCA Insulation Products Inc.:May be applied between crests of steel roof deck and gypsum sheathing in V2-inch-wide ribbons,8 inches on center,at 0.4 gallon per 100 square feet.May also be applied in'lrinch-wide ribbons.6 inches on center,at 0.4 gallon per 100 square feet,between gypsum sheathing and vapor barrier,and between gypsum boards and roof insulation when vapor barrier is omitted.May also be applied at the same rate between layers of roof insulation. B. Mechanical Fastener:(Not shown)Any steel nail or steel clip designed for the purpose may be used to attach one or more layers of insulation to steel roof deck(through gypsum sheathing).The gypsum sheathing may also be attached directly to the steel roof deck with the mechanical fasteners, C. Hot Asphalt or Coal Tar Pitch:(Not shown)May be used as an alternate to adhesive between layers of roof insulation,at a rate not to exceed 35 pounds per 100 square feet. 7. Steel Joists:Type 10J4 or 12K1 minimum size. 10K1 size may be used when limited to a span of 12 feet 0 inches.maximum.As an alternate,any LH Series steel joists spanning no greater than 60 feet may be used.For spans greater than 60 feet.LH Series joists may be used,provided their vertical deflection under total load must not be greater than'has of the joist span. 8. Bridging:Steel bars,'/2 inch in diameter,welded to top and bottom chords of each joist. 9. Cold-rolled Channels:Number 16 MSG cold-rolled steel channels, 1 V2 inches deep with'he-inch flanges must be placed on lower chord of joists and secured with 18 SWG galvanized steel wire.Installed perpendicular to joists,the channels must be located as required to provide hanger wire attachment points. When steel joists are spaced more than 5 feet on center,Iwo cold-rolled channels must be placed back to back and tied together with a double strand of 18 SWG galvanized steel wire at 24 inches on center.The double channels installed perpendicular to the joists and spaced a maximum of 48 inches on center may be placed on top of the joists'bottom chord and tied to each joist with a double strand of 18 SWG galvanized steel wire,or suspended below the joists with 12 SWG galvanized steel wire wrapped around the cold-rolled channels and with the other end wrapped around the bottom chord of the joists. FIGURE 6-8500 SERIES ONE-HOUR FIRE-RESISTANCE-RATED ASSEMBLY ESR-1308 I Most Widely Accepted and Trusted Page 18 of 21 10. Hanger Wire:Number 12 SWG galvanized wire must be twist-tied to steel joists or cold-roiled steel channels.When the ceiling consists of nominal 24-by-24-inch panels or 24-by-48-inch panels,hanger wires must be spaced a maximum of 48 inches on center on main runners adjacent to cross tee intersections.Henger wires must occur at all four corners of light fixtures,at midspan of cross tees adjacent to 4-foot light fixtures and air duct outlets,end adjecent to each main runner splice.When the ceiling consists of nominal 20-by-60-inch panels,hanger wires must be spaced 40 inches on center along main runners,end one wire must occur at each corner of light fixtures,at mldspen of ell cross tees,end adjecent to each main runner splice. 11. Air Duct:Minimum 0.019-inch-thick(26 gage)galvenlzed steel.Totel area of duct openings must not exceed 576 square inches per each 100 square feet of ceiling area.Area of individual duct openings must not exceed 576 square inches.Meximum opening dimension is 18 Inches.Inside and outside faces of duct throat must be protected with'/,a-Inch-thick ceramic fiber paper,laminated to the metal. Maximum dimension of opening is 30 Inches.Duct supported by 1'/2-lnch-deep,minimum 0.053-inch-thick(16 gege)cold-rolled steel channels spaced not over 48 inches on center,suspended by No. 12 SWG galvenized steel wire. 12. Damper:Minimum 0.056-inch-thick(16 gage)galvanized steel,sized to overlap duct opening a minimum of 2 inches.Protected on both sides with Via-inch-thick ceramic fiber paper,laminated to the metal,and held open with a fusible link. 13. Fixtures,Recessed Light:Fluorescent-lamp-type steel housing,nominally 2 by 4 feet or 20 by 60 inches In size.Fixtures must be spaced so their total area does not exceed 24 square feet per each 100 square feet of ceiling erea.When 20-by-60 inch fixtures must be used,fixture stabilizers formed from No.16 gage steel channels,must be used in addition to the hanger wires at midspan of the cross tees.Fixture must be wired in connformence with the National Electrical Code.Fixture and ballasts must be considered for ambient temperature conditions before installation. 14. Fixture Protection—Acoustical Materiel—Armstrong World Industries,Inc.:Type 5/8-inch P(S)or 5/8-inch PC(S)is cut to form a five-sided enclosure,trapezoidal In cross section,approximately 1/2 inch longer and wider,and 5/8 Inch higher,then the light fixture housing.For 2-by-4-foot fixtures,the protection consists of a 233/4-by-473/4-inch top piece,two 5718-by-473/4-inch side pieces,and two 4/2-by-233/4-inch end pieces.For 20-by-60-Inch fixtures,the protection consists of e nominal 20-by-60-inch top piece,two nominal 6-by- 60-inch side pieces,and two nominal 41I2-by-20-Inch end pieces.The top edge of each fixture protection side piece mey be provided with a 1-Inch-deep-by-maximum-20-Inch-long notch near its midpoint.The side and top pieces must be laid in place and the end pieces must be held in place with three 84 nails spaced 8 inches on center.(S)-Surface perforations. 15. Steel Framing Members—Armstrong World Industries,Inc.:Type 8500 systems with a 15/1a-nch-wide flange grid must be used.Main runners,nominally 12 feet long,must be spaced 4 feet on center.Cross tees,nominally 4 feet long,must be installed perpendicular to main runners and spaced 2 feet on center.Cross tees,nominally 2 feet long,must be Installed perpendicular to 4-foot cross tees and spaced 4 feet on center.Grid modules containing light fixtures must employ a fixture-centering dip at each corner.The No.24 gage electrogelvanized steel clip is nested on the flange of the intersecting grid tees,has two 17/la-inch-long legs with their sides perpendiculer to each other,and has a U-shaped return at the top of each leg for engaging over the bulb of the intersecting grid tees. 16. Acoustical Materiel:Nominal 24-by-24-Inch or-48-inch lay-in panels.Border penels must be supported et walls by minimum 0.016-inch- thick(26 gage)painted steel angles with 7/8-inch legs;or,minimum 0.016-Inch-thick(26 gage)painted steel channels,l'/a inches deep with 7/a-inch flanges. 17. Hold-down Clips:(Not shown)Number 24 MSG spring steel,placed over cross tees at 2 feet on center. FIGURE 6-8500 SERIES ONE-HOUR FIRE-RESISTANCE-RATED ASSEMBLY(Continued) Q © 0 ra zra 0 Fir Ca 1. Beam: 2. Normal-weight Concrete 3. Welded Wire Fabric 4. Steel Form Units 5. Steel Joists 6. Bridging 7. Hanger Wire 8. Air Duct 9. Damper:No. 16 MSG minimum galvanized steel,sized to overlap duct opening 2 inches,minimum.Protected on both sides with '/,a-Inch-thick ceramic fiber paper laminated to the metal with adhesive and held open with a listed fusible link. 10. Fixtures,Recessed Light 11. Fixture Protection—Batts and Blankets 12. Steel Framing Members—Worthington Armstrong Venture 13. Acoustical Materiel 14. Hold-down Clips(Not illustrated) For Si:1 inch=25.4 mm. FIGURE 7—TWO-HOUR FIRE-RESISTANCE-RATED FLOOR-CEILING ASSEMBLY(REFER TO SECTION 4.6 OF THIS REPORT) ICC-ES Evaluation Report ESR-1308 LABC Supplement Reissued December 2020 This report is subject to renewal December 2021. www.icc-es.org I (800)423-6587 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:09 00 00—FINISHES Section: 09 22 26—Suspension Systems Section:09 53 00—Acoustical Ceiling Suspension Assemblies REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE(WAVE) EVALUATION SUBJECT: FIRE-AND NONFIRE-RESISTANCE-RATED SUSPENDED CEILING FRAMING SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Fire- and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems.described in ICC-ES evaluation report SR-1308,have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety(LADBS). Applicable code editions: ■ 2020 City of Los Angeles Building Code(LABC) 2.0 CONCLUSIONS The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems described in Sections 2.0 through 7.0 of the evaluation report ESR-1308,comply with the LABC Chapters 8, 16 and 25, and the LARC, and are subject to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Fire-and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems described in this evaluation report supplement must comply with all of the following conditions: • All applicable sections in the evaluation report ESR-1308. • The design, installation, conditions of use and identification of the Fire-and Nonfire-Resistance-Rated Suspended Ceiling Framing Systems are in accordance with the 2018 International Building Code'`'(IBC) provisions noted in the evaluation report ESR-1308, • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. • Main runners shall be identified by indentation or by nontransferable decal with letter not less than Vs—inch high and shall include manufacturer's name and runner designation. This supplement expires concurrently with the evaluation report,reissued December 2020. WC-EV Evaluation Reports ate not to he construed as representing aesthetics or anv other attributes not yet-Orally addressed,star are they so he construed .Itl1� as an endorsement ui the suhjret o(the report or a recommendation for its use,There i.e no warranty hr ICC Evaluation Service.LLC'.express or implied,asm'finding A to am' or other matter in this report.or as to any product covered by the report Copyright t 2020 ICC Evaluation Service.LLC. All rights reserved, Page 19 of 21 E1} ;li;ii ICC-ES Evaluation Report ESR-1308 CBC Supplement Reissued December 2020 This report is subject to renewal December 2021. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council' DIVISION:09 00 00—FINISHES Section:09 22 26 Suspension Systems Section:09 53 00—Acoustical Ceiling Suspension Assemblies REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE(WAVE) EVALUATION SUBJECT: FIRE-AND NONFIRE-RESISTANCE-RATED SUSPENDED CEILING FRAMING SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in ICC-ES evaluation report ESR-1308, have also been evaluated for compliance with the codes noted below. Applicable Code Edition: ■ 2019 California Building Code(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)and Division of State Architect(DSA),see Sections 2.1 and 2.2 below. 2.0 CONCLUSIONS The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Sections 2.0 through 7.0 of the evaluation report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, provided the design and installation are in accordance with the 2018 International Building Code(IBC)provisions,as applicable,noted in the evaluation report,and the additional requirements of CBC Chapters 8, 16, 17 and 25,as applicable. 2.1. OSHPD: The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Section 2.0 through 7.0 of the evaluation report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, with applicable amendments, and Chapters 16A and 17A, provided the design and installation are in accordance with the 2018 International Building Code (IBC) provisions noted in the evaluation report, and the additional requirements in Sections 2.1.1 through 2.1.2 of this supplement: 2.1.1.Conditions of Use: 1. All loads applied shall be determined by a registered structural engineer and shall comply with applicable loads from CBC Chapter 16 and its amendments,and Chapter 16A. 2. Section 13.5.6.2 of ASCE 7 shall be revised in accordance with CBC Section 1617A.1.21 [OSHPD 1 &4]. 3. Design and installation shall comply with the requirements of OSHPD Preapproved Details(OPD)OPD-0002-13 and OPD-0003-13,as applicable. 2.1.2.Special Inspection Requirements: 1. Periodic special inspection is required,in accordance with Section 1705A.12.5 of the CBC[OSHPD 1 &4]. 2. Where gypsum wallboard is used in suspended ceiling installations, additional inspection shall be in accordance with CBC Section 2503.2(OSHPD 1, 1R,2,4&5]. 2.2. DSA: The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Section 2.0 through 7.0 of the evaluation report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, with applicable amendments, and Chapters 16A and 17A, provided the design and installation are in accordance with the 2018 International Building Code (IBC) ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specircally addrevsead,nor are they to be construed AIRS! as an endorsement of the subject o f the report or a recommendation far its us u e.There is no arrunro by ICC'Evaluation Service.LLC.express or implied,as t to any finding or other matter in this report,or as to any product covered by the report ,. _-, Copyright©2020 ICC Evaluation Service,LLC.All rights reserved. Page 20 of 21 ESR-1308 Most Widely Accepted and Trusted Page 21 of 21 provisions noted in the evaluation report, and the additional requirements in Sections 2.2.1 through 2.2.2 of this supplement: 2.2.1.Conditions of Use: 1. All loads applied shall be determined by a registered structural engineer and shall comply with applicable loads from CBC Chapter 16 and its amendments,and Chapter 16A. 2. Section 13.5.6.2 of ASCE 7 shall be revised in accordance with CBC Section 1617.11.16[DSA-SS/CC]and Section 1617A.1.21 [DSA-SS]. 3. Design and installation shall comply with the requirements of DSA Interpretation of Regulations(IR)DSA IR 25-2.13 and DSA IR 25-3.13 as applicable. 2.2.2.Special inspection Requirements: 1. Periodic special inspection is required,in accordance with Section 1705A.12.5 of the CBC[DSA-SS&DSASS/CCJ. 2. Where gypsum wallboard is used In suspended ceiling installations, additional inspection shall be in accordance with CBC Section 2503.2[DSA-SS, DSA-SS/CC]. This supplement expires concurrently with the evaluation report,reissued December 2020. rt w.. ,, FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT i II E II I Transmittal Letter h-I G;A R 1) 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: TOM DATE RECEIVED: DEFT: BUILDING DIVISION RECEIVED FROM: ELIOT ADAMS FEB g 2022 COMPANY: ESSEX GENERAL CONSTRUCTION,INC. CITY OF TIGAHV PHONE: (503)951-9912 BUILDING DIVIS C .. EMAIL: ELIOT.ADAMS@ESSEXGC.COM RE: 11974 SW 72ND AVE BUP2019-00346 . (Site Address) (Permit Number) DARTMOUTH APARTMENTS,LOT 31 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: sa.:4 `.3~��y� .,R4i�Rt�N .,,.z+!Ki�Y'"',�#� i4xe�.� +,�i�:g{�s 61t 4et r�9 i-..h' a�k���.'b. � 4 x«g4:C��s�*.. �1'a%v`r m,4' .z -I�s'. �:i -nag :�O�le�:,q�,?��.'S.�!'1;1Q ,.Qwpe��crtUr;�f'�f1T&!:'�`�'ae,4c�,n,�tti..3st�+sV.�ix14�° �k#'r�tfii;�'�.�d.�C•lY� �.Vi�!a7�..Sptl����k`.�;`. � �. t Additional set(s) of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. 2 Engineer's calculations. 2 Other(explain): Shop Drawings REMARKS: DEFERRED SUBMITTAL:Acoustic Ceilings Product Data,Engineering Reports,&Shop Drawings VALUATION:$30,600 ,, FOR OFFICE USE ONLY .;:+rF Routed to Permit chnician: Date: a--- ,,y- J._ Initials: J it Fees Due. es E No Fee Description: Amount Due: $ 22 {t s l }5�t i tZ " ';' :'` � / 1 c.W1 1 'C v , t'/ $ p�v , . /3 4 w� 1y' t>y�Ik4xxaY�'t 4����t, ��x� ��'�'�� ,,i, ,. :- . $ a 73 . 73 Special Instructions: Reprint Permit(per PE): ❑ Yes No ElDone Applicant Notified: ` -�— -'Pate: ,' �/ /.2-,Z Initials: V