Plans (2) Markup Legend SPRINKLER SYMBOL DEFINITION , MOST HYDRAULICALLY REMOTE HEADS COLOR/LINETYPE LEGEND ` z HEAD GPM PRESSURE REQ'D AT STREET BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). e o //' 9 XXX-XX EXTERIOR WALL 7 ELe�,=IDe• 1 HEAD H.16 13 28.33 GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. ' Delete Line \ / BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O . D MAXIMUM SPACING(TI'P) / \ 2 HEAD H.15&H.11 26.08 43.3 —u— = 1/2"PIPE SIZE w Add One — — — — — SPRINKLER MODEL(TYP) K"/ £ T HEAD SYMBOL(TYP) l / S 1-1/4" •AQUAPEX ^ �R� =3/4"PIPE SIZE $ama Add Tee ( I ( �TO SYSTEM �''A^7 /�- =e= = 1"PIPE SIZE 0 Vogl l O i i V L. =1-1/4"PIPE SIZE CIO '�a• g / TO HOT WATER HEATER I t�� f Sm6� T CURRENT STATIC s'I Add Elbow —I 1"WATER METER / m'"R=,' WATER PRESSURE / ELEV=104 N m<W 3 STANDARD LOSS PER NFPA 13D / i''� CC 1 5 Z'?0 = = �o a Add Coupling (--I STATIC: 55psi (3P5I LOSS FLOWING 26GPM) / 0 1--_1-1/4'FULL PORT uu"i e+m e o I, I, / BALL VALVE CO �JF T1L �/'��]R e R 912 Add Heat ;Q-,�-,Q- / SCN pIDO IllC7 ItD LF ] el esidential Hat Concealed Pendent SS8464 / 0 - - - 15 ��Fy7-�®I axlmum Spacing 16'x16' 1 Of oG F—z gPn` Delete Heed - - STR MTR / RC-RES-16 demo 19gpmCO 7.D4 „o}, � goS „3 ELEV=100' ELEV=108' // LF SENMU Model RC-RES2OS Residential Flat Concealed Pendent SS8464 -`ri<'2.''5`882 Move Head -O- -0- '0."'zm<xo xpm 1"METER 0 - - - 1 K=4.9,205Fe,7/16"Orifice,Maximum Spacing 14'x14' 0moo P-_ixl- _ms Nate:All revisions must be reviewed by Uponor 35'OF 100'OF RC-RES-14-205 Sprinkler head demand: 13 gpm 7.04 zo J o g 3 o s z Table FO02-1 1"COPPER-K 1-1/2"AQUAPEX o0.�ooe tz a >ggi_ 1 Lower Floor o<m< omm<, Multipurpose Fire Safety Systems v Middle iioox o0<eva, The U nor Residential Fire Safe System is aresof the residential potable B U , om< Safety y p WATER SERVICE DETAIL Upper �,roe<> ,- system installed In combination tra She cold side of the or tan install potable .�1 W m p m w B a o water system. Only licensed contractors trained by Uponor can this 16 TOTAL T M°m F zo z._z E 2 s<c 3 - system. \ F1Oo/ NTS W V meC2a"H2-2V�S2gE What to do If Changes are Required / BlI B2an .tou'<B Cola) If any features or obstructions require the addition or on Sr sprinkler J 0--m0c°<i_z}BB' NM heads,or significant relocation of sprinkler heads,contact the Uponor Design = r a Department to determine if observed changes require a redesign n55EEb.n rqxny z.�.E cal* I (BBB.69aJR6). _L I xm Buaivm,0, <�z ri ;1 Mech. �sog=i;r=40-N2P vS}mq wU Porch ate(.—r --"^ iy 0 I 8p„2,2ew„:,,,=De / nl �a ^ \ \I xNyq SSF51ilZZy 4 ROOF LINE ABOVE r.� i y LOW ROOF(BELOW) / i r�r'� "�`� 't m m 3�b xoQ6 / Oz 3y3y S F< =7.--T)— F------- , r- � -O �AA s. Fr I1 J—I 4,1 efts st y VA VEyp y I I •V II y qRN I IIIL r n c I here by certify that this plan,spetlflotlon, S. RC-RES-1$ ( I I I Q W .0 • `\ t I - I or report was prepared by me or under my H.. , I Q \ .{ ( direct supervision and that I am NICET .. I CC Certifie . �.,q MENACE n RG S 1 i RGRES-16 '0R (/) % .1�#jTW -' ( H. ! H 2 I co Q I / y Brent otula Date: 2020 m • 1...-: " I Yr ---J BEET certification No.113889 ( -. .--.1--. I .v Y 1 I rq Water eased Systems Layout-Level N j e -= Certification Expires;June I,2023 ( I �_ I > O 6 3 = I / I I I - O 1 GRES•16 I k ( 0 ( 3 v� �6 "' 2 "�'� __ ?" - plift 11 Q f► O I 9 F•' • `T — AQUAPEx S FRL EL — — ,� F I T.1(8�I C.) Tct; "' Q O N / 1�eru1 � P w - • i CONNECTIONS FROM MIDDLE - \ I z ._. Cr) vcu L 1 Y( _ FLDDR TO UPPER FLOOR ` ,, L 2 i G ?Da-, a • ��` 16 •'n-.'R 41.Pni ( /// \\ \• I \II ;� ILRIr R:t 1� d C H � / / _ - ( u eNN 11 �� ( / \\ pi�" +F ES 1G /y'\ ob 'Y J Q / OGRES l ( 3 m II —5D/OM . r / T:P.-6 4: ,2 g-=.$ repo fl-V L� cw. (n m //�_�.1 T.3LLJ m W lif .� %I . NAMIIIIT.31 ' ,.- ,:,AU 1D_ 31 I'� �� // 7 , 01 `LLJ as 44 aG m ,. PEN TO r .9' - I f I IL _ `\ // ,/ -w / OO 'n wg 6 BELOW I -lt= J ;, F.2r I 1—� u u u¢".�n o o Z WALL I_` �� I \ \� t"AQUAPEX INTERLEVEL ���/' a 1 '? u C-RE' / _-_. / H I(I \ \ N,II CONNECTIONS FROM LOW ER w - >' - ,- --� FLOOR TO MIDDLE FLOOR tt 1. t • RGRE'..1, • II— , \ ® 1 <)- 5 I Q I2 = ¢ l P - RGRES I6 i .„,__Iop ,Y Si s f . •. 13 Pooch ,,_:11 jogs MOVE < IfJ Q m x i m I —� L,in1-�I-° I `� can z = i p • 5 1: i c_�b F61 I a�f RG 16 i O € °w Fa Iii l I r _._ ✓ _ 1--L- a. I— - 5 IT R S16 t.S=. ?, 2-. oDe rT -LOWER FLOOR SHEET DESCRIPTION ALL FLOORS 3 F.,io� 1/4" = 11-0" Di 3 UPPER FLOOR �Z1 MIDDLE FLOOR _ — SHEET NUMBER 9 B b 5 = I ua1 Fl00 • F100 1/4" = 11-0" �I.o� 1/411 1 0 © UPONOR - CONFIDENTIAL Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). z o TxxxGREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. w " Delete une //� - BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. 6 z MAXIMUM SPACING(TYP) =1/2"PIPE SIZE w^ m Add Line — — SPRINKLER MODEL(TYP) —F— =3/4"PIPE SIZE -®o HEAD SYMBOL(TYP) / 4SN`.wN —I— = 1"PIPE SIZE IO Add Tee 1 1 —I= =1-1/4"PIPE SIZE e;2 W o w m �D TH CID E h',16E Add Elbow te9o3 ..a� Add Coupling � i w,'^„m<� Add Head .®-.€ 0,I - n e-d 3 $ Wd W [7IC�� ay fi`0 7^-Op< Delete Head ---ul ,., !e EgoPv+ �_ yniyo n.,22gy Move Head iO `O Note:NI revisions must be reviewed by Uponor b4<o Qe-1f 03a8 6 Z,n} 26- � Table FDD2-1 o<°mQ,^5'4wyi z Multipurpose Fire Safety Systems « w ° The Uponor Residential Fire Safety System Is a residential fire protections ar,° °z B 0 p w gi system installed In combination with the cold side of the domestic potable q' f o£< z 3' water system. Only licensed contractors trained by Uponor run install this W o °tl£<W<r. , . ic.oz1ooc£v<,p3z System. Jyy uy�S�r>u£iggF What to do If Changes are Required V Ez-`3<G15=aRgdN If any features or obstructions require the addition or deletion of sprinkler Hz<Boe°,i°°O u ci heads,or significant relocation of sprinkler heads,contact the Uponor Design Gn<a °2<~o }Z0G o� ue�g c° m Department to determine if observed changes require a redesign `s X I=°z0 i=H a a ii 1 ff e w °a EwE7 ,zz 3PA • oozo Y'o.+°+i y. S • } •I "Oleo° `6 E 5 opym i I f: uo _ �� ? J.� . -BE=n368E oEgj m ��1 L J ` T i T I —` 5.1 MAIN SHUTOFF m 1 1 f � ' lmlll I VALVE LOCATION . ( Y^I Zi l�"A9uaPIX — II f} / TO SYSTEMI v RC-RES-16 j "� 4 - or reportcertify that thls plan, by me or undermy N I /�`\1 '.'I.I CleNfie uPervlion and that I am NICET I , i • RC-RES-16 j RG SS-16j�' FIREPLACE � - -I Brent Imtula/Date:wi /20� 20 1 ////��tk��H 2 'Y H.3 I�LI 1.-- 1 lY 1 NICET Certification No.113889 I • I I — '1111. l / I Water-Basetl SYslertS ne 1, -Level IV I Certification Expires:lune 1,2023 ©'I [L47019 :-. 4 i - I ' T.16 � T.21 . i , 7 j � � � W p V s I 1pqpy .„,RC-RES-1 61 .. `g` I\ i 4• ' II i 3 ¢ d 1t� �, \ ® �_ 1"AQUAPEX INTERLEVEL '^" E�16 - `\ 1"AQUAPEX INTERLEVEL 'm ry II J Ai Y' • CONNECTIONS FROM MIDDLE I H. CONNECTIONS FROM LOWER �` �_ LLL.. ,� c ", q FLOOR TO MIDDLE FLOOR R�RFS16 p ^ F,i1 / ' i OOR TO UPPER BOOR �\ ` E ce T,33 1 3 V&W �� r uwi ` - / 0 7.F 2 T.26 I� / ,., W m e J � i /z \ `►�1' . T.31I // 11,380,,... �, aowg z 32 i',;_. ii f 2 T.29 ail _F.1 II // T '/ W Q G t o ^ ® RC- _t - Ow HALF / ` 'T.3: H 8U0 an m0 p= R gE > © j 1 ' 10� ► F.1 8 ct y REST: (1 Y pp a2 3 —� T / I 4JI 0 3 : RGRES 16 9 aHl OD g x 0 q. �`� - } I H�g a J Q wp m ® +x RC R 1s \ 4 T 39 AO ` I I = z i;; : ys ` - RG -16 0 � Dk,§ _ - i I 2 52gd 2" EA I SHEET DESCRIPTION I -VI CCC ice\ LOWER FLOOR - MIRROR ALL FLOORS-MIRROR e 101/ 1/411 = 1'-Oil 3 UPPER FLOOR — MIRROR z MIDDLE FLOOR — MIRROR L 7 -- SHEET NUMBER F101N F101 1/4" = 1'-0" \ioi 1/41I = 1'-0" © UPONOR - CONFIDENTIAL r Sena RC-RES:Open Web Truss TJI Construction Insulation Recommendations R 7 P See General Notes 8.2.5.7 for Architectural ., AquaSAFETM GENERAL NOTES: In areas subjectspoon to AquaPEX ing, re tubing del akeninunheated sulattic ionce Feature Requirements ' SrpPE%LF Bass Flre to coverldf Uponor delin t completely ullat o with imanufacturer. Insulation q SprinklerkingAdapter Tee should fallow the guidelines of the insulator man Guldli a See Uponor - y £o 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDDON AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor PquasAFE Attic Insulation Guldlines"for attic SECTION 3.3.11.3. Required.If '-Pus n-on Nut installation guidelines(Provided In Contractors Documents package or online O U. UPONOR COMPANY RESERVES THE IXtl.USNE RIGHTS TO ALL DETAILS AND DRAWINGS PS SHOWN ON Blocking Is used, 1�•Mqp, atwww.UPonuroro.com). -i <,.0 THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF 1.0W. COMPANY AND Sce The 2 Tap Screw Holes. J �('I I '�Beim MNountlng Extreme Temperature Installations Planter Bvz Window,say Window or Slmller Feature. G ,n®u UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. ii If no addibnal floor area is Created No Additional Sprinkler is Required. Bracket t°race or AquaSAFE Residential Flre Safety systems are often installed in attics or <in d 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter other areas exposed to temperature extremes of heat and/or cold. Follow / 8'-0"or less O w L12 RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket `-_� • the recommended extreme weather Installation instructions to Isolate and M;°'>o PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE I protect system components from extreme temperatures. Because this RCRESt6 I d e N z0 SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE . system also delivers domestic cold water directly to plumbing fixtures, 9'-D'or less Iv .F. z 0 SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-010 x 1 1/2' Uponor highly recommends that you protect the tubing with adequate / , _ WLn'� 0 '- Full Course tl� insulation in warm weather areas to minimize heating Of the cold water = N S<m; 9. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws supply. 0 3 In Bottom Holes i N'J"'3 NFPA 13D 2016 EDrtION. ' - om � Mmmam 5. 'STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ ' = Installation methods Include,but are not limited to: ry° m n ry m Z ru Tenting over the fire sprinker piping. O H m?: 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead Free flat..- '�'' Additional layers of batt Insulation. If additional floor area Is created.Cannot exceed 18 ft,be more than 2'-0• Concealed • Semu \ r° ` 3a__Concealed •Flat Increased depth of blown-In Insulation. deep,more than g'-0"wide and be with in the coverage area of the tl�,r o.° DAMAGED MUST BE REPLACED. Sprinkler Head sprinkler.No Additional Sprinkler is Required. z:F z rc p Cover Plate oG� '" Caution: If you will be Installing spray foam insulation,make sure to E e F 2 o °S- ], WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. �':' ,� 3 Senu RC-RES:Traditional Wood FramingConstruction rotect all components during application.Consult with the spray foam NFPA 13D Table 7.5.5.3 Distances From P.gV-p° n"<oD 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju manufacturer to ensure compatibility with all products before application, w<,,F W Ez..i 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources i5o�sis 9 WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance y2 „M n S_- ❑ F M 0s D with local building codes. Ordinary Intermediate _f So .-f°z030< PRESSURESUTOMAI L FISHT OFF TIE WATERTEB THATTHE FIRE FLOW SYSTEM,OR SUCH AS WATER OR SmPiX Leda ters Tee - - 00v 6'o1;,'rd rz Fire SpOnM=f Adapter Heat Source Temp. Temp. > GG_ AUTOMATICALLY SHUT THE STOHUTOFF THE VALVES, SHALL NOBE ADDEDD WATER SOFTENERS, Sprinkler Adapter Tee - Push-on Nu, 135*-170• 175.-22S. o o 2 o <o -< o FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES, NOT TO THIS SYSTEMI o z_< 0 5 WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE Bending PEX Tubing Sitle of Fireplace ES, 12" 'o o<'x'p r <s2 THIS SIGN". I )F jj gal ' 11/ Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W c c,h-'oy Z a4� r o 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPIX®"UNLESS NOTED. 1 Max. the outside diameter(a x OD). as' 12" F u'a z-+E t_vi z o H Fire Sprin der Adapter Bottom•f Mounting Bend supports are available for 3/8",1/2',3/4"and 1'Uponor AquaPIX Wood Burning Stove M et Szi ocr£<>3z ll. UPONOR"AquaPIXX"TUBING TO BE SUPPORTED PER NFP0.13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket hi Bracket to am o(TP2S tubing to facilitate 90-degree rigid bends. Kitchen Range 16" 9' Q u E<i-22F <d 1 a 9 `��/ - 18" 9' Li ESc8.n2WU...3 �^Y/ Wall Oven 12. MINIMUM SPACING BETWEEN SPRINKLERS IS R'-0' REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-<10 X11/2" ©� ( Recommended Tubing Length Between Fittings Hot PP Flues IS' 9' V)°m E8iif'e<za <ru BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course . ES' 9' G S R h 85 <r.`- d e RESTRICTIVE SPACING LIMITATIONS. Thread Strews t_.; T� Fitting Sloe Minimum Tubing Length UNnsulated Heat Ducts M Q zs cmH c j _:- In Top Holes LLJ CJ 3/8"ProPEX Fitting 2" Unnsulated Hat Water Pipes 12" 6' = o g 3 N' i<o'U o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING -� 1/2'ProPIX Fitting 2 1/2" Side of Hot Air Diffuser 24" 12" z<w< c 4 t-,,o MOUNTED OBSTRUCTIONS. \.� Mcno Front of Hot Air Diffuser 3 iZ;e 1 a<".Z e a 9 36" 18" 2�a Fvo> <'O 3/4"ProPE%Fitting 31/2' Hot Water Heater 6" 3" o2.2622xo-,0w5,-o 14.THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Leadealed a i.i ,v 1"POPEX Fitting 4 1/2' Furnace 6" 3" ii o e m o 0 N e,. ,-.2 SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Pnnkalelerd SHSeendlu Concealed Flat SOW-250W Light Fixture 6" 3" u•2"'t ut.w Z e m 6 15.THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Nate 11/4"ProPEX Fitting 5 1/2" 12' b" u W W s p o�o w�,�i z 250W-999W Light Fixture S w,n3"uwn FS0°S_ e CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT, If IS e r c .}la_w E THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ 2-noC Uicuu-Oubztx-o'�< w 16.NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. \ • 8.2.5.6. SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPE tubing(white)and ProPEXT"EP Fittings and " Brass Fittings are approved for exposed Installation where the following THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT2 PER SPRINKLER conditions are met(UL 1821 Approved) • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: EXpOSed Wood JOISt Ceihn9 A55Cmb11e5. o H �� V re I here by certify that this plan,specification, p (I)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO 1. Iois[s are of dimensional lumber,engineered wood,wood 1-Joist or open ^' r� m or report was prepared by me or under my 2) ADDITIONAL ADADDI TONAL SPRINKLER PROTECTION ISE REQUIRED. (2)WHERE PROTECTION FLOOR AREA IS CREATED BY AN ARCHITECTURALE FEATURE,NO ADDITIONAL web wood Joists. ® direct supervision and that I am NICET SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Hoist are of depths from 6-162.4In (152-204 mm). ❑ CertNe . (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.]Ma) 3. Joist are of sparing from inches(52-20 10 tom)on center. Q Ft o (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \� THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Mal pipe hangers spaced at maximum 29 inches(610 mm)on center 'IL. 1.55• 1.66" 4. n ALONG THE FINISHED FLOOR are used. Brent Kotula Date: 2020 o (c)THE FLOOR SHALL NOT SE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation Zn -an Hanger 1" Hanger NICET Certification No.113889 PLANE OF THE PRIMARY WALL temperature ating of I55°F(68°C), Water-Based Systems Layout-Level IV v (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Tubing Support Spacing: Certification Expires:lone 1,2023 SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. (Anchor AquaPIX Tubing Securely Enough to Support the Tubing,Yet Relaxed al (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall he used. Enough to Allow the Tubing to Expand and Contract) e ARCHITECTURAL FEATURE. 2. Do not use supports that will damage the tubing.Inspect metal supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32',if Horizontal Runs are t 17.NFPA 13D 6.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor AquaPIX'"tubing with supports.Allow Continuously Supported,Place Tubing Supports SR Six-Foot Intervals. • • • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing Mr freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each THROUGH 8.3.8. a • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FTa(5.1 Ma)AND LESS Floor and at a Mid-story Guide- W z 46. m • M. .3ET SPRINKLERSTH SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT In-line Flow Test V 5 a- '5 MEET ALL OF THE FOLLOWING CONDITIONS: 2 5 o The In-line Flow Test can be constructed on site. It performs a flow test[v m (1)2 THE AREAOATID EEPANEDARE SUREXCEEDIT NONCOMBUSTIBLE Ma). Standard Riser Assembly ensure proper system operation and flow(see Figure F0Ol-8). ko f, (2)THE MATERIALS AND DEFINEDI IN ARE SURFACED WITHIARD ONCOMBUS OF BUILDING CONSTRUCTION.COMBUSTIBLE ��// AS IN NFPA 220,STANDARD ON TYPES BUILDING In amulti-purpose system a single antral valve ivntroh both domestic and L-I_ m n n o • 6,3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety reeds. O='om„rvw,, <' SIMILAR STRUCTURES YY/�/ Uponor AquaPE% 3 ,n..m.. o • B.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE %/////\\ Tubing w °) EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND / \ LLJ V D CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, r U CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING ,,/"" ^/ z a PURPOSES. I p L( z w` O U A • 8.3.5.3 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 0.3.51.1 OR yy%% , w s.3s.1.z. �- - --- - I a¢Gro nA 8`o a • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING J/// fzr70� m UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. o • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THEO O z P. W w uu8 aainz o� DWELLING UNIT AT LEAST ONE UICKRESPONSEINTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling J \-ProPIX Fire E-1 O o QUICKRESPONSE u 12G LL INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE - Spdnkler Adapter EQUIPMENT FROM THE OCCUPIED SPACE. 1'Ball Valve e 8.3.E SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OFTHE PAULDING AT To Hot Water Heater Male Threaded Coupling m • ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. Female Threaded Y • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING - < ,-✓ { CONDITIONS: vJ Tee with Water LL z 8 (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Pressure Gauge O Q F rc 100 FT'(2.83 Ma). m Sprinkler Orifice (Optional) O m ^ ouaix (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS - W IJ '�'m m a) AT THE LOWER CEILING ELEVATION. s Uponor Warning Signs Flow Test w (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE n N ,./ m O rc In r n TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL L To f rmae the,you should ld conduct ct a flow water car pn test. sprinkler = z nil z m M.�-+ (4)SKYLIGHTS NOT EXCEEDING 32 FR(2.97 Ma)SHALL BE PERMITTED TO HAVE PLASTIC COVER. N performance,you should conduct a verification test • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS m ir Q m a-5 L. a o m (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR c p Note: The NFPA 13D Installation Standard does not require flow O J 5 r to m verification, fy z w g e w ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED I- PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. a a. Main Fire Sprinkler ��.s// a G u c a • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR MR-CONDITIONING Shut-off Valve comae contacting the g a flow verification etest, atconfirm the water pressures th ILL ' a qA i F c R O.. ,_ '= z Before mg the Water and Sewer Department of your loaf Ensure the d O u m z S'. EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3,8. _ available water pressure matches the pressure used In the system design. ' SHEET DESCRIPTION 18. Note: The sprinkler plan Indicates the most hydraulically remote sprinkler • 9.1.1,1.1*WETTN PIPFEE GUIDELINESPEANFPA 13D,SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE c_ ," (or pair of sprinklers). FOr rest requirements on other sprinklers,consult GENERAL NOTES&DETAILS $ NCLUDING AREAS PROPERLY a your local code. USEDSEDATERT ALLIITNNIBINSTALLED IN AREAS MAINTAINED ABOVE 40°F, sn INSULATED TON RCAS SUBJECT JE°F. •• A.9.1COVE 1 IN ARIAS BUBINGT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTICO SPACES TO Note: It Is a good idea toat notify the tire inspector at least Inspection2 hours poor to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing an a flow avtei the test.This thmae speed spe or. p, GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the the c SHEET NUMBER ^ SHOW SEVERAL IONWIMETHODS THAT CAN CONTRACTOR CONSIDERED. THESE ARE FOR MENDEDPURPOSESONLY. Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided In FO o i CONSULTATION AN GENERALMATERIALSARECONSIDERED. ORE 90eF WILLBEILLUSTRATIVE RECOMMENDED TO ENSURE Contractors Documents package Or online at www.Uponorpro•com)for T., PROPER METHODS AND ARE USED TO MAKE SURE 40°F BE MAINTAINED. I ' 2 more information In Flow Test nytgp,stone please Performing the r. an Troubleshooting. If there are any questions please contact Uponor. © UPONOR - CONFIDENTIAL