Loading...
SGN2020-00064 CITY OF TIGARD SIGN PERMIT INi Permit#: SGN2020-00064 COMMUNITY DEVELOPMENT Date Issued: 10/5/2020 T I V AR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 1S136CD02000 Jurisdiction: Tigard Name of Business: AutoZone Business Address: 7805 SW DARTMOUTH ST Applicant/Agent: McCormick, Tony Work Description: New wall sign, approximately 243 square feet, located on the south facade. The sign will be internally lit. Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 5'x 48.5' Total Sign Area: 242.5 Wall Area: 4968 Wall Face(Direction): South Sign Height: 26.5 ft. Projection From Wall: 5 in. Illumination: Internal Materials: Aluminum, Lexon Electrical Permit Required: Yes Building Permit Required: Yes Total Permit Fee: $231.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: PlkirLa OfANletrb Permittee Signature: See application ( ' * ► ) RECEIVED City of Tigard OCT 1 2020 :III " COMMUNITY DEVELOPMENT DEPARTTiEN'f CITY OF TIGARD SignPermit A hcation cAi�1pp PLANNING/ENGINEERING SIGN LOCATION REQUIRED SUBMITTAL Address: 7e0$ �.w -�. A*-rM 1)011-1 Suite#: ] 7 ELEMENTS City state: ! J 6/1M?/ OIL -r Zip: J(�7 ) 3 0 2 copies of elevations on tl',2"x 11" Tenant or business: 4v i 7-41"E or I1"x 17"pages(Mall sign elevations must include dimensions Property owner name: t $ c Pro 7 O l iJ la L-L- of sign and wall face and show the �J P /� location of sign on the wall. ,yiL Address: r / 78 Ay . C /�, 674)6 - Freestanding sign elevations must CI -state: f / t} YJJ/✓t1l.S/T17 i}l� L-r / Zip: 5 zej - '-/37 be drawn to scale.) Phone: Email: 0 2 copies of site/plot plan,drawn to scale,on3'iz"x II"or11"t17" /1/iEy47 - iil a /n. 0i Q ,+kQ� pages(not required for wall signs) Sign contractor: I U ❑ List or diagram of all existing sign Address: 15 Zc 5- (�. Ave p dimensions and square footage City/state: t ' 6frpo a Q 1 ip: 97, 14 0 Application Fee Phone: 171 Z,2- J-O 1J Email: ;e r5�./l9Fy-,t.J/o,J di), et) CCI3 license#: 6 / a/Y f27 NOTES: Expiration date; OA)/ I y 'A�n7 e • Freestanding signs over G ft.in height Contact person: ( fib and walls signs of which any clement weighs 20 lbs.or more require a building permit for construction. SIGN DATA(Complete all items in this section) If any element of a wall sign weighs 70 lbs.or more,plans must be prepared TYPE (Check all that apply)ff‘ New sign by a structural engineer. 0 Freestanding 0 Electrical • Building permits require 2 sets of ❑ Alteration to El Wall construction drawings and,if sign is 0 Freeway existing sign ❑ Roof 0 Other freestanding,2 copies of site/plot plan and 2 sets of engineering must Be Isubmitted with building permit t � Sigs��s,n#: application. dimensions: (h) 1_(w) = Z�2 18 sq.ft. sign area J 1 I (III `,1 1I l- 1 '-I. ONLY Nc�vsign:Z7Z•,,//1�q.ft.+ Existing sign area -��sq.fc=_Total 2T L �yY �� Tool sign area:Z7l.I8sq.lt./48 building face sq.ft. _416 ./.of bldg face Case No.: S��W- T 1 I• Height to top o���: �' 0 ft. Projection from wall: 5 in. Related Case No.(s): Materials: t A ' "' Fee: $231 Application accepted: Is the sign under 20 lbs.? W Yes ❑ No By: it-- Date: 1 w(S[w (Building Permit required if over 20 lbs) Direction wall faces (circle one): N 0 E \X' NE NW SE SWApplication determined complete: By: Date: (<)I5I24) Will the sign have illumination? d/ Yes 0 No If yes,what type: i�7 Internal 0 External t�Canmunity oeveropmentkURtl us ons142 APIALS roans Rnd � temptetes\lrnd Vse Appliutbns Rev 12/14/2012 City of Tigard • I.iI 2i SAC I fall Blvd. • 1 iganf,(Irri()11 '712 + • v wu:tigard ongov • 503 7I 8 2421 • Page 1 of2 APPLICANTS NOTE: Person specified as"Applicant"shall be designated`Termittee"and shall provide financial assurance for work. *When the owner and the applicant arc different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S)SHALL CERTIFY THAT: • if the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby acknowledge that I have read this application,that the information given is correct,that I am the owner or authorized agent of the owner,and that plans submitted are in compliance with the City of Tigard. GN CURES each owneri f the subject grope aired. • /0 `t . � C It a2� a7-6 pplica '•signature Print natfie D to lo l w O er s si a Print name to Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 2 APPLICANTS NOTE: Person specified as "Applicant"shall he designated"Permittee"and shall provide financial assurance for work. *When the owner and the applicant arc different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby acknowledge that I have read this application,that the information given is correct,that I am the owner or authorized agent of the owner,and that plans submitted are in compliance with the City of Tigard. SI RES each or of the subject prope gaited. /� • • y Applican s si ature Print name Date 91'4v •PM l i 01,E' 2' �Lo O er s si ature Print name to Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of 2 Agnes Lindor From: Tony McCormick <permits@meyersignco.com> Sent: Monday, October 5, 2020 11:49 AM To: Agnes Lindor Subject: RE: Autozone Caution!This message was sent from outside your organization. Allow sender I Block sender He does. From:Agnes Lindor<agnesl@tigard-or.gov> Sent: Monday, October 5, 2020 11:48 AM To:Tony McCormick<permits@meyersignco.com> Subject: RE:Autozone Great,thanks! Does Stephan represent 7805 SWD, LLC? From:Tony McCormick<permits@meversignco.com> Sent: Monday, October 5, 2020 11:45 AM To:Agnes Lindor<agnesl@tigard-or.gov> Subject: RE: Autozone Here you go Agnes, sorry about that, I forgot to send the 2nd page? From: Agnes Lindor<agnesl@tigard-or.gov> Sent: Monday, October 5, 2020 11:24 AM To:Tony McCormick<permits@meyersignco.com> Subject:Autozone Hi Tony- We received your Sign and electrical permits for Autozone. Please sign page two of the application and provide owner authorization for the signs.Thanks, Agnes Lindor I Associate Planner City of Tigard I Community Development 13125 SW Hall Boulevard Tigard, Oregon 97223 Phone: 503.718.2429 Email:AgnesL@tigard-or.gov DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." 1 6OLS FACE LIT CHANNEL LETTERS w/ STRIPES (Qty 1) AZ1CL60-581-5LINT Auto Zone 7805 SW Dartmouth St. Tigard , OR 97223 SQUARE FOOTAGE: 242 AZ1 CL60-581-5LEXT ( Sign # 1 Drawing ) 48'-51/4" RECEIVED Ie'-0' f f 30'-2 1/2" O C T 12020 CITY OF TIGARD //Rad I I FDA i 2,000 PLANNING/ENGINEERING 4 Wil CITY OF TIGARD Approved y Planning Date: lol5p2 FRONT VIEW Q� SCALE:3/16'=1'-0" Initials: AL MATERIAL BREAKDOWN GEMXPO-1 Modules P/S Si 12 52 14 S3 18 1 J 54 26 !�i T f��- 55 41 > ft f / 7-2�� i 56 52 1 ffI f I�j�/�/�)f� r/f// I .�....-..�* Y y � !�J MATERIAL LIST157 56 rJf�- _ i GEMxPO-1 366 Mod 1fi3 Ft GEM%RP1 147 Modules P/S ---- LED Module GEMXRD-1 466 Mod 233 Ft A 81 1 LED LAYOUT u 52 SCALE:NTS 1 Power GEP512-60U-NA 8 Ea T 36 Supply 0 52 1 Supply Wire 9409 235 k Z 84 1 0 Choose one wire 192160005 62 Ea 0 52 0 l 1 connector 191600041 62 Ea N 55 I I 1 End Caps 191600041 30 Ea E 54 SPECIFICATIONS 0 1. 3/16"THK PIGMENTED PLEXIGLAS RED 2662 AUTOZONE LETTERS 2. AUTOZONE LETTERS INTERNALLY ILLUMINATED wl GE TETRA MAX RED LED • 3. 5"16"THK PIGMENTED 0 LACK/ HI E ORANGE UM211 AUTOZONE STRIPES -,,,///90/02V0/70 4. AUTOZONE STRIPES INTERNALLY ILLUMINATED wl GE TETRA MAX ORANGE LED 5. 5"PRE-FINISHED.040 BLACK/WHITE ALUMINUM RETURNS LETTER LOCKED&RIVETED TO BACK AND CAULKED I INSIDE OF LETTERS AND STRIPES TO BE WHITE Q0 6. 7 GLOSS BLACK JEWELITE TRIM FASTENED TO LETTERS&STRIPES wl MINIMUM 2'GAP IN BACK PANEL #8 SHEET METAL SCREWS PAINTED P-8/SPACING SHALL NOT EXCEED 18'/NO FEWER TO ALLOW ACCESS TO THAN FOUR(4)SCREWS PER FACE ©0 ELECTRICAL WHIPS 7. WHITE/WHITE ACM BACKS LETTER LOCKED&RIVETED TO RETURN AND CAULKED (Attachment Detail) ® NIGHT VIEW WALL SYSTEMS APPROVED FASTENER 8. WHITE ALUMINUM TAB w1®VINYL APPLIED FIRST SURFACE V-3 SCALE:NTS 9. AUTOZONE REQUIRED MOUNTING HARDWARE:TOGGLE BOLTS-EIFS WALLS OR 9. 3(8" DIA. Lag W/3/8" Shield &Washer 0 ® WOOD,CONCRETE BLOCK OR EIFS 3/8"THREADED ROD THRU BOLT elim p. MASONRY LAGS-CMU/MASONRY WALLS/INSTALLER TO PROVIDE HARDWARE wl NUT&WASHER - (REFER TO WALL SYSTEMS w/APPROVED FASTENERS CHAR COLORS/FINISHES m T) 4 +-i318"THREADEDR�THRU-BOLT wIMETAL OR EIFSe 0 10. 1/2"FLEXIBLE CONDUIT/GREEN FIELD I I P-7 SW 6091 RELIABLE WHITE ,NI limir, TOGGLE ANCHOR 11. 1/4"DIA WEEP HOLES _ P-8 GLOSS BLACK 12. 120V-20 AMP PRIMARY ELECTRICAL CONNECTIONS I TO BE MADE BY LICENSED V-3 ARLON 143 POPPY RED HI PERF.TRANSLUCENT VINYL Ill( T�l CONCRETE,MASONRYAND BRICK r 14 ELECTRICAL CONTRACTORSEN _ 1 r: -EMBED A MINIMUM OF 3" 918"DIA LAG w/3/8"SHIELD&WASHER 13. ETL APPROVED ELECTRICAL SHUT OFF SWITCH 4" ® 31e^DIA RED HEAD LARGE DIAMETER 14. TETRA POWER SUPPLY MOUNTED TO BOTTOM OF TRANSFORMER BOX TILT-UP CMU-EMBED A MINIMUM OF 7" TAPCON FASTENER 15. INTERIOR RACEWAY AS NEEDED:4"x 5°H x.063 WHT/WHT ALUMINUM BREAKFORMED 0 0 --.A.,—, — INTERIOR TRANSFORMER BOX w/REMOVABLE FACE I PAINTED P-7 BUILDING "FORALL OTHER WALL CONDITIONS NOT USTED ON THIS APPROVED FASTENER SCHEDULE,INSTALLER IS TO DETERMINE Clio US CONFORMS TO A SUITABLE METHOD OF ATTACHMENT FOR SIGNAGE AND OBTAIN APPROVAL FROM JONES SIGN. NAOLL VISIBLE SCREW HEADS&POP RIVETS PAINTED P-B FASCIASECTION DETAIL "' UL STD 48 - 'IF INSTALLER IS UNSURE OF AMETHOD,JONES SIGN MUST BE CONSULTED.f-0RALLATTACHMENT METHODS,INSTALLER SCALE: NTS Intertek MUST ADHERE TO GUIDELINES ON USE AND SITE PREPARATION RECOMMENDED BY FASTENER MANUFACTURER p� REV. I DATE I or I DEea FT I WENT APPROVAL DATE ��jj SHEET NUMBER JOB#:000000-R2 1 0118.19 JE RISTALLERTO PROVIDE HARDWARE r ACM BACKS.LETTER LOCKED AND RNE'^.: Site# .J O N ES SIGN DATE 00.00.0000 2 02142I XX IIPDATEVaGLLfIt1TFROM3MTOMlONrRELINEucfFAACE WEIL 3 00010.00 XX XXx°. 4 00.00.00 XX ,xo LANDLORD APPROVAL DATE Your Vision.Accomplished. DESIGNER Jenee Sotka 5 00.00.00 XX xrxx ftOI ON CITY,STATE ZIP .O c 00.0000 XX xxxx 4��Jv�..N SALES REP:XXX ' °0°°°° XX'' WWW,JONESSIGN-COI a 0s XX s.N XX XX.v OC II PROJ MGR:Sandy Mansfield o°uum XX XX XX xx. DESIGN PHASE:CONCEPTUAL This is an original,un unpublished drawing Jones Sign Co.,Inc.It isyour personal use in conjunction with a project being planned for you by JONES SIGN.It is not to be shown to anyone outside of your organization,nor is it to be used,reproduced.copied or exhibited in any fashion.Use of this design or the salient elements of this design in any sign done by any other company.without the express written permission of P abY JONES SIGN,is forbidden by law and carries a civil forfeiture of up to 25%of the purchase price of the sign.JONES SIGN will endeavor to closely match colors,Including PIS,where specified.We cannot guarantee enact matches due to varying compatibility of surface materials and paints used.All sizes and dimensions are illustrated for clients conception of project and are not to be understood as being exact size or exact scale. Ti Auto Zone 7805 SW Dartmouth St. and OR 97223 g ( South Elevation Drawing ) ( Sign # 1 ) , \ / "VAIPArti/0100Z0 3111 ii ., (.5) ... 1 , . I. co Ell N 1. ir ■■■■■ ®._ is ■■■■ .--.-- i =I-- Scale = 1/4" = 3' • 1 84'-0" ' FILE INFO: REVISIONS: CUSTOMERAPPROVAL, � sales@meyerslgnco.cam PROJECT: Auto Zone - ACCT.MGR: _ ... o If ay: This u an orlginU unpubllAed dressing created f« Attention: Meyery .customer and ne project planned Ck DRAWING: specific www.me ersl neo.eom ADDRESS: 7805 SW Dartmouth St. SHOP MGPo I. INITIALS DATE for me stxde< needs N Meyer Sign Customers Corm shownMMlS artwork are for representational purposes only. y 8 -' 2- 3- 4- 5- 6- These drawings are not to be Mown outside your Wilkie rinter,printing lysp an copier or computer manila display phone: 503 620-8200 PHONE: Tigard, OR 97223 SCALE : LANDLORD APPROVAL: organization nor asm,roofed rer»muKee,a ummnaa In day wry unless y of Oregon. n.writing q an oFfl<er a cannot exaall duplic the ate tual he true color of the materials used 0 fax:it, 503 620-7074 DESIGNER TLM D A T E Meyer Sign eOnpnyofOe$On making tl OF ',NITIAI5 ()AII. • , SITE PLAN ° � ,% ... L',.._. 7805 SW Dartmouth St. - .t-ice r < ' Tigard, OR 97223 - Ti a mow '' r r -,..c as i .r L � , P n.� --. r �..y* f x 1 !- Description of work: r di. a r , a y �• Install 1 set of Auto Zone p ".= ' .- . , ,a ! � ' - ' ', , a channel letters with stripe, and , 1: ,y . -© a l 2 sets of Auto Zone channel • : —.r r a, -r _fix"* l $ W ," �' letters without stripe on ' " r a r. x - ,, � � '� tenantsNorth, South and West ,. ;: s' No h, ' . , '�� _ f — Elevations illidie /.sue• z ...- Meyerign Contractor: L _: _ •., .. _ _ i- Sign Co. ofOregon V . f ' � ' .� _ -� 7805 S Dartmouth St i /' 15205 SW 74t" Ave W -''' 4 • i • Tigard, OR 97224 _ ,_ - • - r gj. - ;,f n 50 620 8200 • _ ' . • • r Contact: Tony McCormick ' , ® - ° Business to receive sign: cb I Auto Zone t 3- r , * • �° = k r 11 7805 SW Dartmouth St. Tigard, OR 97223 ` rt' r i^ •• - — .mod -- r r t ii Scale: 1/1 6r, 9' .^ r r r r_r r .. .. ( I - kru r r r r r r r G.i' -�. _ r�5 • r r r r r r r. ! ,:.� , ,. North . r -nit r r r r r i` r re 1 r r ' ..., .. ♦ u$. r�.. :; 1• NU �� r ,' r- r r r r r f 5 � ) = xs .., , ■S rAl�' �'� r r r A r ., ' - r I - ,; _ r "AA r .go '' II Si — a. - r 4 ,. 1 f - . . , Sig'ii (jo. of . • 0 Y F �{ OF OREGON -• _ _., 15205 SW 74th Ave • Tigard, OR 97224 /rnol c-an o,nn