Loading...
Plans (8) ll 1I I � REVISIONS BY GENERAL NOTES DEMOLITIONENEAL GCODES FOJECT IDATA S - EET I 05/23/18 BIDSET/ PC I. PRIOR TO COMMENCING WORK NE CONTRACTOR IN COTERENCE WITH THE BUILDING I. THE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS ALL WORK SHALL CONFORM TO APPLICABLE GOVERNING STATE CODES: TENANT: TRILLIUM HEALTH, INC.(CENTENE CORP) ARC)-IITECTURAL MANAGER, SHALL PREPARE A LIST OF ACTIVITIES THAT WILL, IN ANY WAY, AFFECT THE WORK AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME. NO EXTRA NORMAL OPERATIONS CF THE BUILDING AND NEIGHBORING TENANTS, AS COMPENSATION WILL BE ALLOWED THE CONTRACTOR FOR THE EXPENSES DUE TO H15 TIGARD MUNICIPAL CODE - TITLE 14 - BUILDING CODE ADDRESS: 13221 SW 68TH PARKWAY, 5TH FLOOR, SUITE 500 APPLICABLE. PROTECTIVE MEASURES AND SCHEDULING SHALL BE ESTABLISHED TO NEGLECT TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS WHICH AFFECT HI5 WORK TIGARD, OR 91223 A-0000 TITLE SHEET, GENERAL NOTES, PROJECT DATA, VICINITY MAP MINIMIZE DISRUPTION AND PROTECT PROPERTY NOT RELATED TO THIS PROJECT. 2014 OREGON STRUCTURAL SPECIALITY CODE (0550) (BASED ON 2012 IBC) 2. THE CONTRACTOR SHALL SCHEDULE THE WORK 50 AS NOT TO INTERFERE UNDULY WITH A-001 REFERENCE SITE PLAN 2. THE CONTRACTOR 15 LIABLE FOR DAMAGE TO THE BASE BUILDING AND TO TENANT NORMAL BUSINESS OPERATIONS. HE SHALL ALLAY DUST BY APPROVED MEANS AND 2014 OREGON PLUMBING SPECIALITY CODE (OPSC) TAX LOT ID A: 2510IDA00102 WOK THAT 15 TO REMAIN_ EXISTING WORK AFFECTED BY CONSTRUCTION. SHALL BE MINIMIZE NOISE AS MUCH AS 15 PRACTICAL. IN NO CASE SHALL THE WORK Nil tra-ttEt A-002 EGRESS AND SIGNAGE PLAN PATCHED AND REPAIRED OR REPLACED AS REQUIRED TO MATCH THE ORIGINAL WITH EXISTING STREETS, DRIVES, WALKS, PASSAG=EWAYS, PEDESTRIAN TRAFFIC AND THE 2014 OREGON MECHANICAL SPECIALITY CODE COMSC) LOT SIZE: 5.81 AC R CII VED CONDITION. LIKE. 4-100 DEMOLITION FLOOR PLAN E 2014 OREGON ENERGY EFFICIENCY SPECIALITY CODE (OEESC) ZONING: MIXED USE OVERLAY:MUE MAY 2 9 2018 N F;if• U 3. THE CONTRACTOR SHALL CHECK THE CONTRACT DOCUMENTS, FIELD CONDITIONS AND 3. WITH THE EXCEPTION CF ANY SALVAGEABLE ITEMS (AS DIRECTED BY THE OWNER TO A-101 FLOOR 4 FURNITURE PLAN a a DIMENSIONS FOR ACCURACY AND CONFIRM THAT THE WORK 15 CONSTRICTABLE AS BE SALVAGFD) ALL REMOVED MATERIALS SHALL BECOME THE PROPERTY OF THE 2014 OREGON ELECTRICAL SPECIALITY CODE (0E5C) SEISMIC DESIGN CATEGORY: D CITY OF TIGARD - _ ° a� � SHOWN, PRIOR TO COMMENCING WORK IF THERE ARE ANY QUESTIONS, THE CONTRACTOR ITEMS TO BE RELOCATED WILL BE INDICATED ON THE PLANS. A-200 DOOR 4 HARDWARE SCHEDULE, DOOR DETAIL3~ JILDING DIVISION .� 6 n � - CONTRACTOR SHALL INFORM THE ARCHITECT IN WRITING AND OBTAIN CLARIFICATION 2014 OREGON FIRE CODE (OFC) BUILDING DESCRIPTION: EXISTING 5-STORY OFFICE BUILDING 133,134 G.S.F. ^� :� 'O o 4. ALL ITEMS DEEMED SALVAGEABLE BY THE OWNER WILL EITHER HAVE BEEN INDICATED WITH MULTIPLE BUSINESS USE TENANTS. A-300 DEMOLITION REFLECTED CEILING PLAN W - n a) FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK !N QUESTION OR RELATED -E, W ON THE DRAWINGS OR REMOVED PRIOR TO THE START OF DEMOLITION OR WILL BE ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDING FACILITIES. p1 °` " N a°7 DIRECTED BY THE OWNER TO BE STORED BY THE CONTRACTOR AND SHALL REMAIN OVERALL FLOOR 5 AREA: 24324 SF GROSS 4-301 REFLECTED CEILING PLAN ❑ a `;''N`° a 4. THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT DISCREPANCIES THE PROPERTY OF THE OWN -' EFEER NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) E FOUND BETWEEN EXISTING CONDITIONS AND THOSE SHOWN ON THE DRAWINGS SO THAT PRIMARY BUILDING OCCUPANCY CLASSIFICATION: B BUSINESS USE (NO A-400 FINISH PLAN J C > c0 A CLARIFICATION MAY BE ISSUED. 5. CONTRACTOR PRIOR TO ANY DEMOLITION WORK, SHALL COORDINATE WITH ALL OTHER CHANGE IN USE PROPOSED) (FORMER UNIVERSITY OF PHEONIX ADULT ^ u ., Ep° TRADES (ELECTRICAL, PLUMBING, ETC.) IN ORDER TO CONFIRM EXACT EXTENT OF EDUCATION - B OCCUPANCY) A-500 ENLARGED RESTROOM PLAN, FINISH LEGEND, 1 SOLID SURFACE 5. ?Krrtt¢NCE TO MAKE, BRAND, AND MODEL 15 TO ESTABLISH TYPE AND QUALITY DEMOLITION WORK TO BE PERFORMED. IF THERE ARE ANY DISCREPANCIES, CASEWORK DETAILS 714' Q oDESIRED. SUBSTITUTIONS FOR "EQUIVALENT" PRODUCTS WILL NOT BE ACCEPTED IMMEDIATELY CONTACT THE ARCHITECT FOR COF CTION, CLARIFICATION OR CONSTRUCTION TYPE: II-A. FULLY FIRE SPRINKLERED. U TUNLESS SPECIFICALLY APPROVED BY THE ARCHITECT. ADJUSTMENT. A-501 P-LAM CASEWORK DETAILS 6. THE DESIGN CONCEPT OF THIS PROJECT I5 BASED ON THE COLOR DESIGN AND 6. CONTRACTOR SHALL R E R TO CONSTRUCTION PLAN DRAWING FOR EXTENT OF NEW A-600 ENLARGED BREAK ROOM 4 MOTHER'S ROOM PLANS, �eD 49cECONSTRUCTION AND INTERFACE OF NEW TO EXISTING WORK COMPLIES AND SHALL FIRE RESISTIVE RATINGS (IN HOURS) TABLE 601. ELEVATIONS, EQUIPMENT 4 HARDWARE LEGENDSTEXTURE OF FINISH)=D Pi�JDUCTS SPECIFIED. fF THE GONIRACTOR FAILS TO ORDER MATERIALS IN SUFFICIENT TIME FOR ORDERLY INSTALLATION, THE ARCHITECT WILL COORDINATE AS NECESSARY_ .•TH : H. '•SEN c1NOT ENTERTAIN ANY REQUEST FOR MATERIAL SUBSTITUTION WITHOUT THE OWNER'S CONST. TYPE II-A C�<3UILDING ELEMENT TYPE_ A-lOO ACCESSIBILITY 4 CONSTRUCTION DETAILS APPROVAL. INSTEAD, THE CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY 1. AREAS UNDER CONSTRUCTION ARE TO BE KEPT BROOM CLEAN AND ALL EXISTING 1 R0 Mr... ...>:, CALIFORNIA MATERIAL TO REMAIN f5 TO BE PROTECTED 50 A5 TO ENSURE THAT NO DAMAGE WILL STRUCTURAL FRAME, COLUMNS, GIRDERS 4 TRUSSES A-800 CEILING SEISMIC SUSPENSION 2 FINISHES AND INSTALL SPECIFIED MATERIALS UPON ARRIVAL. - cls ARI-11468 d OCCUR BEARING WALLS - EXTERIOR 4 INTERIOR 1 qT EXP.1231-18 3. 1. THE CONTRACTOR SHALL DETERMINE ALL LEAD TIMES FOR CrtCIFIED MATERIALS AT �• OF THE TIME OF BIDDING TO ASSURE AVAILABILITY FOR THE PR OJECT A.5 THE 8. THE CONTRACTOR SHALL REMOVE ALL WALL CONDUITS LEFT AFTER WALL DEMOLITION, DEFERREED /SEF=',ARATE 61/4 SCHEDULE I�QUIR7=5. fNCLUDIIJG SWITCH BOXES, PLATEb, BRIDG�sES, OR ANY OTHER TELEPHONE OR PERMITS NON-BEARING WALLS 4 PARTITIONS - INTERIOR 0 MSCI-IAN I CAL ELECTRICAL WIRING OR EQUIPMENT. 1 M-100 MECHANICAL TITLE SHEET a DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 1. MODIFICATIONS TO EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEMS, FLOOR CONSTRUCTION INCLUDING BEAMS 4 JOISTS 9. REMOVAL OF EXISTING GYP. BOARD SHALL BE MINIMIZED AND PERFORMED ONLY AS SEPARATE FIRE PERMIT, AS REQUIRED. D 9. ALL WALL DIMENSIONS ARE FACE OF FINISH TO FACE OF FINISH UNLESS SHOWN OR NECESSARY TO ACCESS NEW ELECTRICAL OR PLUMBING CONNECTIONS. ROOF CONSTRUCTION INCLUDING BEAMS 4 JOISTS M-101 MEGHANIGAL SCHEDULES AND DETAILS Z NOTED OTHERWISE. M-20I PARTIAL FIFTH FLOOR CEILING PLAN - MECHANICAL �- O 10. RE-ESTABLISH COMPLETE SERVICE TO ALL EXISTING FACILITIES, WHERE DISRUPTED BY Q 10. ALL CLEAR DIMENSIONS ARE REQUIRED TO BE EXACT WITHIN 1/4 TOLERANCE ALONG THIS CONTRACTOR DEMOLITIONEs Es _ FULL HEIGHT AND PDLL WIDTH OF WALLS. "CLEAR" OR "HOLD" DIMENSIONS ARE TO DESIGN OCCUPANT LOAD CALCULATIONS `'` - o M-301 PARTIAL FIFTH FLOOR CEILING - MEGHANIGAL J FACES GF FINISHED CONSTRUCTION. 11. CONTRACTOR SHALL REFER TO ALL OTHER DRAWINGS INCORPORATED IN THIS WORK `CONTRACT FOR THE EXTENT OF DEMOLITION WOR5COPF OF Z 11. ALL ANGLES ARE 45 OR 90 DEGREES UNLESS OTHERWISE NOTED. SUMMARY DEMOLITION OF NON-LOAD BEARING WALLS, DOORS, FINISHES 4 CABINETS. NEW OCCUPANT ELECTRICAL Z O 12. ALL WALLS ARE TO BE "CHALKED" ON FLOOR FOR ARCHITECT'S APPROVAL PRIOR A�ARD OI I S MATERIALS NOTES LIGHT RECOTENANT NF URED HVAC, ELECENTS TOTALING TRICAL, P MBING 4 FIRE SPRINKLERS69 SF. NEW WORK INCLUDES WALLS, ,AND USE AREA LOAD OCC. LOADE_1OO ELEGTRIGAL TITLE SHEETILING, W U TO FRAMENG, AT THE GONERS pISGRETICN �,} FINISHES. FACTOR r 13. THE CONTRACTOR SHALL FREPARE ALL EXISTING SURFACES A5 REQUIRED TO I. GUAR ACRQ+IOl1,LEDGES THAT ARCHITECT SHALL HAVE NO RESPONSIBILITY FOR THE SUITE 500 E-1OI ELECTRICAL SCHEDULES AND DETAILS RECEIVE C4 tCIFIED FINISH, PER MANUFACTURER'S RECOMMENDATIONS. DISCOVERY, R TIOVAL, PRESENCE,HANDLING, DISPOSAL OF CR EXPOSURE OF PERS( +IS TO HAZARDOUS SUBSTANCES,MATERIALS, WASTES IN ANY FORM AT THE PROJECT SITE, I E-102 ELECTRICAL SCHEDULES AND DETAILS 14. SHOP DRAWINGS (MUST BE PROVIDED FOR ARCHITECT'S REVIEW BEFORE MILLWORK INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBEEBTO6 9ROD'UCTS, FCB MOLD, OR OTHER A C C E 5 5 I B I L I T Y RE M E D I A T I O I �t BICE/ PRIVATE OFFICES/ CORRIDOR 14,111 SF * 1:100 141.11 FABRICATION COMMENCES. TOXIC SUBSTANCES. E-103 ELECTRICAL SCHEDULES AND DETAILS PRINT/9-ACNE/MAIL/COLLABORATION/ HOTEL 1,140 SF 81 1:100 11.4 15. GENERAL CONTRACTOR SHALL SCHEDULE AND COORDINATE OWNER'S/ TENANT'S 2. THE OWNER/TENANT 4C(NOU.EDGES THAT IT ACCEPTS RESPONSIBILITY FOR NOTIFYING THE PATH-OF-TRAVEL AND FACILITIES SERVING THE MODIFIED AREA OF SUITE 500 E-104 ELECTRICAL SCHEDULES 4 DETAILS TELEPHONE SYSTEM AND COMMUNICATIONS VENDORS FOR INSTALLATION OF THESE Ama,riiATE FEDERAL,STATE ,AND LOCAL GOVERNING AGENCIES FOR ANY DEMOLITION, ARE 100% DISABLED ACCESSIBLE PER CITY OF TIGARD BUILDING PERMIT MOTHERS ROOM/ RESTR3OC^'IS/LOBBI 962 SF 6 1:100 962 SYSTEMS. CONSTRICTION CRREPAIR WLC ( BUP2011-00265 RECENTLY COMPLETED. E-201 PARTIAL FIFTH FLOOR PLAN - ELECTRICAL DEMOLITION 16. WHERE NEW OR FUTURE WALL HUNG CABINETRY OR SHELVING OCCURS, PROVIDE 3. ANY Q.ESTICNS NAT ARISE RELATED TO A56ESTO6 (CR Act)SHALL BE ter rEKEE) TO STORAGE/ NETWORK/ IT/ ELECT/JAN. 1,046 SF eo 1:300 3.46 E-30I PARTIAL FIFTH FLOOR PLAN - POWER AND SYSTEMS ADEQUATE BACKING IN WALL AS REQUIRED. TI-E OWNER/TENANT FOR RESOLUTION. INTERIOR ARCHITECT SHALL NOT BE REaJIRED TO DO ANY WORK NCR RENDER ANY OPINIONS RELATED TO ASEESTOS. COFFEE ROOM 236 SF 6 1:100 236 E-302 ENLARGED PLANS - POWER AND SYSTEMS C Il. ALL WORK SHALL MATCH EXISTING CONSTRUCTION, QUALITY AND METHODS UNLESS ZZ OTHERWISE NOTED. 4. THE CANER/TENANT SHALL RETAIN AN IMIDE IT CONSULTANT WHO 15 TRAINED AND TRAINING 1315 SF 1:20 65.15 E-401 PARTIAL FIFTH FLOOR CEILING PLAN - LIGHTING E) ERENGED N IDE TIFICATICN AND SURVEY OF EXISTING SITES FOR HAZARDOUS X IS. LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE. DETAILS TAKE MATERIALS PRIOR TO START CF DEMOLITION CONSTRUCTION E-501 PARTIAL FIFTH FLOOR PLAN - FIRE ALARM AND W PRECEDENCE OVER ALL. CONTRACTOR SHALL NOTIFY ARG IITECT OF ALL CONFLICTS HUDDLE ROOMS 451 SF 6 1:100 4.51 SECURITY SYSTEMS Q IN WRITING FOR P1�IMPCONTRACTORS T RESOLUTION. 5. ALL CONTRACTOAND SJR'A BCGNTCTORS SHALL REPORT THE PRESENCE § OF ANY MAIJr4AL OR AS5EJ15LY SUSPEc.1ED TO CONTAIN AS ESTOS U CN DISCOvERY. THE WORK CONF. ROOMS (POSTED OCC. LOAD) 1,423 SF 9 1:34 AVE. 42 IS. GENERAL CONTRACTOR SHALL PROVIDE FINAL CLEANING INCLUDING, BUT NOT LIMITED SHALL B E CARRIED OUT PER THE CONSULTANT'S RECO`T'ENDATIONS. TO: GLASS AND FRAMES, NEW AND EXISTING GLOSSY SURFACES, MILLWORK, FLOORS, D DOORS, FRAMES, HARDWARE, WALLS, BASE, AND LIGHT FIXTURES. BREAK ROOM (POSTED OCC. LOAD) 1,123 SF * 1:24 46 PLUMBING U ., , � N P-100 PLUMBING TITLE SHEET ilei N 20. CONTRACTOR SHALL VERIFY DIMENSIONS AND COORDINATE WORK WITH INSTALLATION FIRE NOTES TOTAL SUITE 500 23,091 SF 339.11 CC E. CF ITEMS 'NOT INCLUDED IN THIS CONTRACT" (NUL.).) Z P-101 PLUMBING DETAILS `� CC 21. THE PATH OF TRAVEL FROM THE PUBLIC WAY, DISABLED ACCESSIBLE PARKING TO I. THIS REMODEL MAY NECESSITATE THE RELOCATION AND/ CR ADDITION C FIRE SPRINKLER 2 EXITS REQUIRED, 2 EXITS PROVIDED EE LL O 1S THE AREA OF IMPROVEMENTS AND TO THE RESTROC SHALL CONFORM TO STATE SYSTEM RE -FADS BECAUSE OF WALL CR CEILING VISIONS AND/OR A CHANGE IN USE OR P-201 PARTIAL FIFTH FLOOR PLAN - PLUMBING DEMOLITION _ AND FEDERAL DISABLED ACCESSIBILITY STANDARDS INCLUDING DOOR HARDWARE OCCUPANCY GROUP FOR WHICH A SEPARATE SUBMITTAL AND FERMI IS REQJIRED.SUBMIT131ECA ' THRESHOLDS,KICKPLATES, MANEUVERING CLEARANCES, AND SIGNAGE, ETC., U.ON. SHOP DRAWINGS (4 COPIES)OF ALL FIRE SS-FRINCLER SYSTEM I-EAD RELOCATIONS AND/OR P-301 PARTIAL FIFTH FLOOR PLAN - PLUMBING ADDITIONS TO THE CITY CF TIGARD,PLANNING AND DEVELOPMENT SER'ACES FCR REVIEW Z Q P 22. THIS PERMIT DOES NOT APPROVE ANY EXTERIOR SIGNAGE. SEPARATE PERMITS ARE AND AFYF VAL UNDER A SEPARATE EER`'IIT.1.1J-ERE IT 15 DETERMINED THAT FIRE REQUIRED FOR SIGNS_ SPRINKLER SYSTEM HEAD RELOCATIONS AND/CR ADDITIONS ARE NOT NECESSARY,A oz III STATEMENT TO THAT EFFECT SIGNED BY AN APPROVED, LICENSED FIRE SPRINKLER 0 23. DISABLED ACCESS SIGNAGE SHALL BE EXISTING AT ALL ACCESSIBLE ENTRANCES CONTRACTOR OR A ORECCON STATE LICENISED ARCHITECT CR PROFESSIONAL ENGINEER J IL FROM THE PARKING LOT, AT ALL ACCESSIBLE PARKING STALLS, AT PRIMARY SHALL BE 5UBMI 1!EU TO THE TIGARD FIRE DEPARTMENT'S FIRE CODE OFFICIAL AT THE CITY ENTRANCE TO THE TENANT FACILITY, AND AT ALL DISABLED ACCESSIBLE OF TIGARD PERMIT CENTER 13125 SIJ HALL BLVD.,TIGARD,OR,91223. RESTROOMS, STAIRS, EXITS, ELEVATORS AND PERMANENTLY LABELED ROORMS. 2 2. THIS REMODEL MAY NECESSITATE THE RELOCATION AND/OR ADDITION OF FIRE ALARM 24. CONTRACTOR SHALL ESTABLISH CONSTRUCTION WASTE DIVISION PLAN TO MEET SYSTEM DEVICES BECAUSE OF WALL OR CEILING REVISIONS AND/ORA 0-64IN sE N USE CR PROJECT D F S I GN TEAM CITY OF TIGARD co LOCAL SITE ORDINANCES. OCCUPANCY GROUP FOR WHICH A SEPARATE SUBMITTAL. AND PERMIT IS REQUIRED.SUBMIT &j SHOP DRAWINGS(4 COPIES)Of ALL FIRE ALARM SYSTEM DEVICE RELOCATIONS AND/OR REVIEWED FOR CODE COMPLIANCE N 25. CONTRACTOR SHALL RECYCLE AND/OR SALVAGE FOR RE-USE A MIN. OF 50% OF ADDITIONS TO THE CITY CF TIGARD,FLAWING AND DEVELOFi'1I=NT SERVICES FOR REVIEW PROPERTY MANAGER Approved l ] 1.1 V NON-HAZARDOUS CONSTRUCTION 4 DEMOLITION DEBRIS, IF REQUIRED BY AND APPROVAL UNDER A SEPARATE PERMIT.WERE IT IS DETERMINED THAT FIRE ALARM IRI JURISDICTION SYSTEM DEVICE RELOCATIONS AND/CR ADDITIONS ARE NOT NECCESSARY, A STATEMENT CBRE ASSET SERVICES OTC: I I - TO THAT EFFECT SIGNED BY AN APPROVED L1C NSED FIRE ALARM CONTRACTOR CR A 26. THE EXISTING BUILDING ENVELOPE 4 THERMAL INSULATION IS EXISTING TO REMAIN. OREGON STATE LICENSED ARCHITECT OR PASSIONAL B INEFR SHALL BE SURlMI I Ikl> 421 T AND, AVENUE Addrit #: t t) -=l J TO THE TIGARD FIRE DEPARTMENT'S FIRE CODE OFFICIAL AT THE CITY CF TIGARD PERMIT PORTLAND, OR 91204 13125 SW HALL BLVD., TIGARD,OR, 51223. VICINITY P: (503) 980-1129 Airitc #:• � � `S� e-‘6,;-) 1:- A/\(� CENTER P PROJECT / \ C: (503) 333-0561 S • 13221 SW 65TH CONTACT: CHELSEA PARKWAY, 5TH FLOOR � By: +T I DAC: LZ CO TIGARD, OR 5223 OC �TIOlEMAIL: CHELSEAGOBELCBRECOM W NT5 CONTACT: KALIF PAPASADERO I- co- 0 CC ` EMAIL: KATHERINE.PAPASADERO*CBRE.COM ADDITIONAL PERMITS REQUIRED Z Z I T IONS 5 TENANT! CORPORATE PROJECT MANAGER 2 Fire Sprinkler �'/ a 0 S.F.LIE SQUARE FOOT J BOX JUNCTION BOX O SHEET NOTE O DOOR KEY • Fire Alarm �1 CC CO CENTERLINE LT LIGHT CENTENE, INC. 0 A :... 1100 FORSYTH BLVD. (FACILITIES) Mechanical W W ADJT. ADJUSTABLE MAX MAXIMUM GH MECHANICAL REVISION REFERENCE a INTERIOR ELEVATION ST. LOUIS, MO 63105 Plumbing �� Z ADJ ADJACENT ME , KEY P: (314) 349-3606 X 8088606 Electrical I rLrU� AFF ABOVE FINISHED FLOOR MFG MANUFACTURER A-I G: 0314) 349-8842 V Q CAB CABINET MIN. MINIMUM OR MINUTE 1 I i Truss Engineering w Q CTR CENTER (NNEW A 1 DETAIL KEY CONTACT: STEPHEN COCHRAN CLG CEILING NIC NOT IN CONTRACT `' ' EMAIL: SCOCHRAN*CENTENE.GOM Shop Drawings IIS CLO CLOSET NTS NOT TO SCALE 100 SF ROOM AREAE. Other c�c CLR CLEAR OG ON CENTER SECTION KEY 1 OCCUPANT LOAD w F'^ C COL COLUMN OFF OFFICE A-1 ,n PROJECT ARCI-IITECT 2 U CBC CAL BUILDING CODE PLAM PLASTIC LAMINNATE ',.�� CO CEC CALIFORNIA ELECTRICAL PO PRIVATE OFFICE C 7 .E, )--IDL DESIGN 0 W - CODE PLYWD PLYWOOD �~���� �;� - "s' 1410 GLEN VIEW CT. ROSEYILLE, CA 95141 (� J Z CFC CAL FIRE CODE (R) RELOCATE 't O - CMC CAL MECHANICAL CODE REF REFRIGERATOR 'P, P (916) •113-6158 w I- cc 0 DF DRINKING FOUNTAIN RE ) REQUIRED 9P F (916) 113-0518 DET DETAIL STD STANDARD CONTACT: HEATHER LARSEN, ARCHITECT o I-- �" DN DOWN STO STORAGE `' EMAIL: HEATHER�'HDLAIA.GOM U- ., p DWR DRAWER 55 STAINLESS STEEL �O - 0 05/23/2018 DATE ELEV ELEVATION OR TEL TELEPHONE ti ELEVATOR TYP TYPICAL `E-).. MEC)-I, ELECTRICAL AND PLUMBING ENGINEER SCAB AS NOTED EQ EQUAL T-24 CALIF. ADMIN. CODE, (E) EXISTING TITLE 24 G4LU ENGINEERING, CORP EF EXHAUST FAN UON UNLESS OTHERWISE - MGR HHL FE FIRE EXTINGUISHER NOTED 52 MILL HILL ROAD, PO BOX 55 JOB FLUOR FLUORESCENT VCT VINYL COMPOSITION " ? - BLOOMSDALE, MO 63621 CEN014 FOG FACE OF COLUMN TILE P. (314) 731-4220 SHEET FUT FUTURE VIE VERIFY IN FIELD C: (314) 541-0425 GYP. BD. GYPSUM BOARD - 0 A.000 W/ WITH r>: . _ ;. . F- (314) 469 542 HT HEIGHTW/O WITHOUT CONTACT: JEFF AST, PE . I OF SHEETS HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE 40-1 TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIiSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I �� REVISIONS BY I 05/23/1E L '8T 4 STREET ODE BIDSET/ PC I - - 0 PU$L IC SE 11�t - - \SIDEWALK / 1 T 1 / • - - / ci I I Illy/ __.-4-11------, to r•-• ov (I) ni 00 Ng . - v r 1 i h h ° 0 co ,,,2..4 O V Y Ol Of E 0 PI , gp 1 1 0 1 _. T1'P_ �, � u � 8 4:i I , o 1 'SSIIED 49% Etttij HEA ER 11 1g NV .4N1 i g ) 1 1 „_,/ �� _ �R05EVILLE, CAl1FORNIA- 45.1b. r iii �'! f _ CAS ARI-11468 ml.J 1 r .4T Ems.tz-3118 `fes ., it �� r== { �PUBLIc ' �' SIDEWALK 7 Z ,• r 11 ihk. siT �L,ar� s�+EEt r�otEs ! L7 • \ \\ _ ' _ 0 r C.3 ill DISABLEDESSIBLE STLS, CURB GUT <SICdVAGE. HOFTRAVEL FROMri 04 AGCE551BPARKING: TO PRIMARY BUILDINGENTRANC:CI) DISABLED AGGESSIt3LE VIAEXISTING= CRETE WALKWAYS. / I r (E) PATHRAVEL FROM THE PUBLIC WAY, r INDICATEH HEAVY DASHED LINE. \ 3. (E) LEVEL C NGI�TE (MAX GROSS 4 RUNNING \ I / SLOPES 2%) LANDING AND W4LKWAY IMAXIf 1 ik \\.\\ GROSS SLOPE 2�, MAX_ RUNNING SLOPE 59�) Z E 0 0- AT EXTERIOR EXIT DOORS TO REMAIN AS-IS. J h I1 O 4. (E) DRIVEWAY ENTRANCE W/ ACCESSIBLE ` ? Q PARKING. AI S I ING (WHITE). j f ici" .\ . 5. (E) ACCESS SLE TRP co I 6. (E) ACCESSIBLE PARKING STALLS AND I CESS TO BE MAX2% SLOPE IN ANY �� AGE LE DI}�GTIDN USE (E)FLUSH CURB ELEV. r \ . I mt_m�t. p j �. CxG TO ADJUST ALL EXtERIOR DOOR CLOSERS PER 12/A-20ra, AS NEEDED. TYP- I J [� 8. (E) ACCESSIBLE PARKING SIGNAGElPOLE Z s"; IL O -l- ,7re, I:L-----"'''a=-=---= I/ 0.___3___., CENTERED ON (E) PARKING STALLS. F. O r . (E) PARKING STALLS t GROSS WALK TO 0 Prl I REMAIN TVP- TVP• k3UILD IMGs III a F 5 STO .X OFFICE W 133,134 SQ. FT, r rp I I \\\�k� 3z \ `;. \ "r\\.. :: ..: 1111 ...,....,:::...„,,,m,,,\--ritic...,,nctwx,vix.. ...-..,.. :::::m" ...,,,--::..„..,\• ....,..-ii:. „iii ,,,,„---. :..j,!#::,.t:!T..!--!:!_!,.!-.i..i.,i., ,i;!,,nukt::.:]\,..:-.."z•tk: :::!:.::::,:..,.::-.,,,,.!!_ciiiiiiiik:itti.zi::2.-:!:::-:,,.:::,1, - . . v!i.::::!::,:,.,:,:::.::•: .t.:-:.,,, -.:-!-;::,.*Hlo-.), ;k,-, ',,,, ,,,,.4N,,,k,t% ..,.:..„..::,:i,,,,,. ....,41%\„4...:..:,,,„. ...:.,:m*:.:.•.....,....,.:,..:,,,,,,:k4,,v,„,,..„ 1,,, ,., ,„,.,:::,,,,„t<,...,,;:t....„:::„,.. ...,. :,..,..::.,.:,,„,,,,:..::: ..,.,,,,,,, ,t,,,:\,,,:,,.,,,,,), . ,,\.N.. '.1.... . _ . -. )k1(11767410K • '\• A'... ..'''''L ::.•\ ‘‘NzW:":.' 1.,\L-...\\V....•-'1VV... ''''.:.:: \":\ \ 1''IC .,.„...••„.„''..-..:''''''.:'::: k *.::, vvvt»\\\\vi\v\, , „ �' Tal co � '�� .. ° :air' , � � ��f� � �,,*,...,,,,-\.;v:,, -. \��"' ;:i:::::i-,iiiW.3:,, .:.:-.WC:::ajP,NO.::,]i:.ili,iii:?.:"..".; ' ...::.W:;$.:\ . "\\. M1 ,M1 q, 4 t. CC uL CC IfS1 Zil.::: :::,,,,,,,:.\k,INIT.vm.,„:::::.,.:,,,,!,k::::,:::%,,...,,,,:.::..,..1„,:,....„.. ::::::. ,. .!:1;t:4,711Z::;:' Iiiikii :::.;iiiVN'tW..]::.:;:ii,i,:ift!, +1„..:! .:::::iklIgUt'VE:.!.:j:.:..:Aiii0 4•t;04„ 7, , N4.-.i:,,i,...:-:::::! \ �\ �� 1 , Q -,::.::::i:,:--:::,::Aa.:,:t:--ptim-......:..:miiii'.L:oolviit,. ]:.-y.,.,..r.:itk, , \\.,:;t, .-',---k4EN,01„...,a-44:E \ hw. gkilt: ., v' �\ , \\�\�� \171 9 0 0 ^ „, ,\\ , ,,,.‘ ...,:,.:::..._.::::.*,,,N:::‘,. ..:%.:::r.::,-AR:]:::,:„:4:;: .:,.. ,e::,,A...,..-..::: :-.1)ra::..:**,:„,:k\,::::.1:iii:%,..:.V.iit: , • i.,.... ..: .. .. ,., ......., ......., ........ ..,\_........„.......,,‘.,,,,,,.., . ;:....„..:.....,: . • , •.. th.,par,„\I SIS i�5�\s4�Sl` i ' ” * ,.. . v \ I .ii.1!:.!:." . ' ' '.:',..i:i.iAlL*, :.. :! ..!!...:.:.. X Y�Lt � a NI.\N „.,„41..„.0*,..4.:::•:-.....;::,;,k,,,,,,,,mi;i_tie5:,.:.-:.-,',:::N 5w:-:.4:i.1::: :ftii:-.:*.x..li \It' ' , \\\N:, . ,' ' " `' .2 i \ w `� L�1 I.'',� \.f \ y.t\l'l I ti,.. x \11104%* YYY \ld�`� nliV.. V �i * i .e - .�\\*\4. a tw.'4� t° `\��� ��R��l .,,, ` t\ , `\' % * 'Aik .yeti r vk :� e V� \ v in k:':'-it104:,,-JlikiNII:-:;k:':4:aii*:*.ii::t.1 74A '•'''s:'\ ' ' ' " ' ky,.,, '•.•,:". .]::".' a...„::::n... ''.•::f-•.Nz:i::-,2*.n..:': -..:',. ::',:':••.-- 1-...•• •'''•%:.'...:k:-.i.::: IN-L...- ', ‘‘, .''''s' : `. <:>v �.,' >" 11 \'" ,t 1\\\.\\14.; 1 DATE p5/23/201 B FLOC1R ..� � \~t\ti.,. _ \ �sC.:Y ', �I, 4o 1�A,il"'Pt \tiUljIR 0 J r \�\ ... .; \\ r„',, AS NOTED v MGR .'N\34 N\\....'k..-') '.***k4:::. : -•-•••4": ::•.'• ..:.... .7:- ':".1'\,'1' HHL t� �.;:,:-''''''N''.."....1: ...:, \\\,4! ..V , INi !:":NUtlik v . IV�M� I �� \ JOB \\� � ,`� _ �� I CEN014 ���yt17$t.�C « :' � �, <A�vvv�� �':��. •`'�x ��ati` d a� �a:c$�,�i �( \ ......FQ` :�::.��� - ��\��\V�� ., ;,i*.,,"e�� SHEET � � TE PLAN � 'tet 2�i ��' � � EXISTING SITE MAP NO SCALE REFERENCE SI SCALE : , = 2O'-O A_001 I I t I OF SHEETS HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE 4)T TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I TACTILE EXIT SIGNAGE: (PER 2014 OSSC 1022.9 4 1011.4) - WHERE REQUIRED, TACTILE EXIT SIGNS SHALL EE REQUIRED AT THE FOLLOWING LOCATIONS: REVISIONS BY I. EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE ExIT WITH THE WORD°EXIT•. POSTED OCCUPANCY SIGNS EGRESS PLAN LEGEND SUMI''ARY 05/23/18 BIDSET/ PC 2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS CF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BT A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: 1100 5F ROOM AREA OCCUPANT A. 'EXIT STAIR DOWN' REQUESTED REDUCTION IN DESIGN OCC. LOAD B. "ExIT RAMP DOILN" BASED ON SEATING PROVIDED, PER 0550 1004.1.2, USE LOAD FACTOR OCC. LOAD C. "EXIT STAIR Up" 15 1/OCCUPANT LOAD FACTOR (ACC. 0:= ACCESSORY USE PER IBC 4 0550) D. "ExIT RAMP UP" EXCEPTION. POST SIGNS IN VISIBLE LOCATION, PER 3. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS of AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY OSSC- 6 6 OCCUPANT LOAD PER IBC (0560) SUITE 500 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS,"EXIT ROUTE". 4. EACH ExIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY NAT 15 REQUIRED TO HAVE A VISUAL EXIT SIGN, O CONF. 1: MAX. 12 OCCUPANTS (6;f:)- ACTUAL ACCUMULATED OCCUPANT LOAD X1`1 LIGE/ PRIVATE OFFICES/ CORRIDOR 14, 11 5F I:lmm 147.11 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS,"EXIT ROUTE". (ARROW POINTS IN TI-4E DIRECTION OF EGRESS) 5. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS, TO EXIT". B CONF. 2: MAX. 6 OCCUPANTS SIGN REQUIREMENTS: PRINT/ Pl-IONFJ MAIL/COLLABORATION/ HOTEL 1, 40 SF 1:100 114 1. FINISH 4 CONTRAST. CHARACTERS,SYMBOLS 4 THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS 4 SYMBOLS SHALL CONTRAST WITH • 4. E THEIR BACKGROUND,EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR G CONF. 3: MAX. 14 OCCUPANTS MOTHER'S ROOM/M/ RESTRX11S/ LO6BY 962 SF w 1:100 9.62 c u, n ° DAR<CHARACTERS CN A LIGHT BACKGROUND. EGRESS WIDTH PER OCCUPANT (IBC 100532) (OSSC) ,n 2. CHARACTER HEIGHT. CHARACTER 4 NUMBERS ON SIGNS SHALL BE SIZED O o .6 2. CHAR INT TO THE vIEWING DISTANCE FROM WHICHRSO THEY ARE TO BE READ. 3„ O CONF. 4: MAX. 10 OCCUPANTS DOORS: =02 IN/ PERSON STORAGE/ NETWORK/ IT/ ELECT./JAN. 1,046 SF Q 1:300 3.46 'q g 2 2 THE MN.HEIGHT 15 MEASURED USING AN UPPER CASE"I". LOWER CASE LETTERS / ) ( I y ARE PERMITTED. <>BREAK: MAX. 46 OCCUPANTS MIN. INDIVIDUAL DOOR CLEAR WIDTH ALLOWED: =34 ^� 3. RAISED CHARACTERS.WHEN RAISED CHARACTERS ARE REQ'D ON SIGNS, r"ExIT" " COFFEE ROOM 236 SF w 1:100 236 W -6 n n a, THEY SHALL CONFORM TO THE FOLLOWING REQUIREMENTS. Lu A CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISEDY,-INCH ZDgE 2 �tR;4INING: MAX. 65 OCCUPANTS EXIT DOOR CLEAR WIDTH PROVIDED 34" x 2 DOORS: =68" TRAINING 1,315 SF 1:20 65.15 V (0.794 MM)MIN,4 SHALL BE SANS SERF UPPERCASE CHARACTERS n BRAILLE 4 `''" ACCOMPANIED BY GRADE 2 BRAILLE. CHARACTERS SHALL NOT BE ITALIC, LU OBLIQUE,SCRIPT,HIGHLY DECORATIVE OR OTHER UNIUSUAL FORM. `nw R,AISED CHARACTER EXIT DOOR CLEAR WIDTH REQ'D: 339.11 OCG. x 2: =6182" OK HUDDLE ROOMS 481 SF 6 1:100 4.81 •- z z a B.CHARACTER SIZE: RAISED CHARACTERS SHALL BE 5/5-INCH(I5.9 III) 9C�hl U C7 d �` �} HIGH MIK 4 2"(51 III)HIGH MAX. 16 VERBIAGE ` 0 D LLI CD T MEET EXIT STAIR WIDTH: =52" CONF. ROOMS (POSTED OCC. LOAD) 1,423 SF 19 1:34 AVE. 42 Z Q o C.CHARACTER PROPORTIONS:RAISED CHARACTERS ON SIGNS SHALL BE : CONDITION SELECTED FROM FONTS WHERE THE WIDTH CF THE UPPERCASE LETTER"0" 0 (BRAILLE Is e0z MIN.4 Ilmx MAX.of THE HEIGHT of THE UPPERCASE LETTER°f. Y TENTER OR GAPACITY(SPRINKLERED): 52"/.2.260 BRROOM (POSTED OCC. O OCC. EACH X 2 STAIRS: =520 OCG. - OK !BREAK M ( STELAD) 1,123 SF 6 1:24 46 STROKE THICKNESS OF THE UPPERCASE LETTER"f"SHALL BE IS%MAX.OF THE HEIGHT CF THE CHARACTER 6 49 JU5TIF EG^D) 49 LU D.CHARACTER SPACING:CHARACTER SPACING SHALL BE MEASURED Z BETWEEN THE TWO GL05E57 POINTS OF ADJACENT RAISED CHARACTERS a CD BLACK W,, O COLOR TOTAL SUITE 500 23 091 SF 339.11 �(+ Lu WHHI COMMON PATH OF EGRESS TRAVEL (IBC 10062.1) (0660) s/ HEATH H. LAR ) MINI-()(i"MN.•BASE CF NON-RECTANGULAR CHARACTER CROSS Z LETTERING �C SECTIONS)4 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAX. Q f l - q�D NOT TO EXCEED IN B OCCUP. W/ FIRE SPRINKLER SYSTEM =100' 2 EXITS REQUIRED, 2 EXITS PROVIDED r f -d E.LINE SPACING:SPACING BETWEEN THE BASELINE OF SEPARATE LINES OF X- co SIDE CF ROSEVILLE, CALIFORNIA CHARACTERS WITHIN A MESSAGE SHALL BE 135%MINI 17096 MAX OF THE CHARACTER HEIGHT. r RIGHT OR _ �� ARI-11468 0 HAND SIDE EXIT ACCESS TRAVEL DISTANCE (ICC TABLE 10112) (OSSC) y EXP.12-31-18 4. BRAILLE. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER CF DOOR �� 61/4BRAILLE IS RECD IN pTHER PORTIONS of THESE STANDARDS. POTS SHALL BE FOR�"(254 MM)ON CENTERS ON EA CELL WITH "(7b MM)spACE BETWEEN DOUBLE NOT TO EXCEED IN B OCCUP. W/ FIRE SPRINKLER SYSTEM =300' F CELLS,MEASURED PROM THE FIRST COLUM4I OF DOTS IN THE FIRST CELL TO THE LEAF FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED Y,." DOORS (0,635 MM)MINI TO)n"(0.3nm)MAX.ABOVE THE BACKGROUND.BRAILLE SHALL MINIMUM NUMBER OF EXITS (IBC TABLE 10063.1) (OSSC) BE SEPARATED "MN.AND)4"MAX FROM OTHER TACTILE CHARACTERS. , ' w TACTILE EXIT SIGNAGE OCCUPANT LOAD < 49 e--, Zi, wo SCALE: NTS D.TACTL.OR OCCUPANT LOAD > 49 < 500 =2 l"- Q 5 201E OREGON Z EXITS PROVIDED =2 W J 2 MAX SEPARATION SHALL BE 1/3 DIAGONAL OF SPACE IN FILLY SPRINKLERED BUILDING z 2J W - (.) r . , ,.............. ....______,T--,.._____ _______________________„ . -------- , = _ m---. =, _ :L.: ,�; SI-IEET NOTES: O rio,..,. ._ car.i. . 812m. ca.Laxisorat wf:_a_2. -,-.7. - m2:4_ z ~�-'' 412 • 611 342 206 �`'- .� I I I 1 163 O SEE A-S00 FOR ENLARGED EXISTING TOILET ROOM PLANS. 163 OPEN OFFICE 4 I 34.3 • 100 100 343 1@0 100 `--`'''-.�- 1 2 348 I 12 6.11 3.42 6 I 2. PROVIDE NEW TACTILE "EXIT ROUTE" SIGN ATO LOCATION CI- 163 I 100 OPEN OI*IC 1 I 1-63 NOTED ON PLAN PER DETAIL 1, THIS SHEET. (PROVIDE BACK W ..'` PLATE IF MOUNTED ON GLASS). PRICE OPTION TO MATCH X13 ``. 123.48 O 1 2,430 �. BUILDING STD. WOOD SIGN PLACARDS. V.I.F. LOCATE SIGN ON g 141 ~'''- \ rIL I 100 IN ACTIVE LEAF OF PAIRS Off DOORS. 1 839 N I 243 144 W 100 '' 11.46 �A}; I 100 N _ � �. 7 1 100 3. POSTED EMERGENCY EVACUATION PLANS SHALL BE v I 83c� • I 5� �j 144 SUPPLIED BY TENANT E INSTALLED BY GC AT TENANT EXIT CO 0 1.41 `-.. 100 1,141 �/ �. '� y - J I 100 DOORS 4 IN A TYPE LARGE CONF. ROOMS 4 TRAINING ROOMS CC N �'- 0�6 100 10.56 AS REQUIRED.I� - 11.41CAE= ''''''-' 8 6 146 ENTRY/EXITpa 2 144 4• TENANT TO MAINTAIN MIN. 44" MIN. CLEARANCE AT ALL EXIT J 146 TSAR 1 � 113 I P>P� Li" 1 100 All84 / 84 V 9� _ '�``:�,` ,..,...,. / ACCESS AISLES. SEE FURN. PLAN A-101. LL O 1.46 1 100 1 100 I 1 100 / 4 300 138 100 100 CC 1.44 O 084 I 0_84 0.9i / «I FAIL 8 0.48 100 5. NOT USED. 1 103 1.13 :.::><::'< ._ j. 6. EXISTING EXITS WITH 5' X 5' MIN. LEVEL LANDINGS AT GROUND g .,.............. .........,, ....... .. I - SAFE 138IIIIIIV IC © D �..........: _ LOOK - �1 F Q F StOR4C�3..../ STORAGE I �� 206172 Y _ � 198 _ '---„ 142 139 I - . ---..<> 1. REMOVE EXISTING "STAIR" SIGN IF NON-COMPLIANT ANDcc 1 235 300 '-.. ELEvatOR g - 1 300 300 300 • 1 10@OW4 100 DN 6 / 0b6 '- j_OBBY O I 0,_&9 6 � PROVIDE NEW TACTILE EXIT STAIR DOWN SIGNS AT LOCATIONS 4.. O O pN, + I 1�2 454 NOTED ON PLAN PER DETAIL I/ THIS SHEET. V.IF. 1F REQUIRED. < 0.4� 0.46 I 235 �" .,._____.,,I . r�'�. ~1``- -- � 1 COORDINATE COLOR ¢ DESIGN IN COMMON AREAS WITH -1('; - ��' LinI _ 1 325 rE -- / ., O O 431FAIL 4` •• I 14 BUILDING MANAGER ¢ CO 1 123 / I 100 SAFE © 21rO S. EXISTING ELEVATOR SIGNAGE TO REMAIN, u.ON. -DISTANCE liilr = Ili I_ - - J BETWEEN I 123 0 43110FA ��� `' -� I `/ l i ,�� O S. EXISTING FIRE ALARM PULL STATION g STAIRS. N c/:ii 16356 EXITS = , -. / 144'-5", OK I/MIMI ' I 1.4 b .. DISTANCE TO in OPlcN OFFICE 3 EXIT = 132'-9" 0 0 i r ��'� � � OPEN OFFICE 2 144 14,000 OK % ,( 24.4 I 2 , 52 1 100 `�‘‘ / ® O r,` \ .�,-''� I 100 I 1.44 I I 100 40 �`� F / rr 1 TRAVEL 121.52 .`. / i 11caug ►! -�D15TANCE t0 .w,4 Z STORAGE 2 `. / 1 24 EXIT = 11'-2" '-.._ I 144 J 215 .\ / I 46 / , �'' 1 100 300 \`� _-.. r u - I 1.44 i, 111 0.12 •` I ' W / 71._____7 `� TRAVEL OFFICE 8AOFFICE11 DISTANCE 1 156 1 155 '- 163Q 1. `163 I 135 1 135 4 �. TO EXIT= �'' 100 1 351 / �. 124'-9" OK �I I 100 1 100 DIAGONAL DISTANCE OF SPACE = 263- .,� 1 Z 100 1 10@ 1 100 / •� I 1.56 I 1.55 REQ'D DIST. BETWEEN EXITS: 1/3 x 263 - 5-1'-a" 1630 Fl I 1.35 I 135 I .-:, lb3Co 10 / tR4MM�i SOI `� ' ' 0 I 236 / 1,315 . / Er . ,' 1 100 1 20 �. - Z / r a 236 165.-15 / CO.4_ -.i..:: - Ill - 4=1 - d 0010000000 ,00 \ ' ,�, �' DIAGONAL DISTANCE = 5i'-4" 0� REQ'D DISTANCE BETWEEN EXITS= 1/3 x 51'-4"= 11'-1" W TOTAL OL.=339.11 TYPICAL O -DIAGONAL DISTANCE OF SPACE = 48'-g" DATE 05/23/2018 ©©0 REQ'D DIST. BETWEEN EXITS: 1/3 x 45'-9"= 16`-3" SCALE AS NOTED MGR HHL JOB CEN014 SHEET 0FIFTH FLOOR EGRESS AND SIGNAGE PLAN A002 __ SCALE . 3/32" = 1'-0" z ... OF SHEETS HDL DESIGN HEREBY EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NIDI TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I DEMOLITION PLAN SHEET NOTES: SYMBOLS LEGEND REVISIONS BY 05/23/18 0 ALL IMPROVEMENTS INDICATED ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 14. REMOVE PORTION OF (E) WALL AS REQUIRED FOR NEW DOOR OPENING. SALVAGE 29. REMOVE ALL PREVIOUS CARPET TILES (ORANGE) 4 RUBBER EASE. - - - -- - WALLS TO BE REMOVED BIDSET/ PC TILE BASE AT RESTROOM FOR PATCHING. EXISTING WALLS TO REMAIN 2. REMOVE ALL CONSTRUCTION, WINDOWS AND WALLS SHOWN DASHED (AND 30. REMOVE WOOD BASE ON DEMO WALLS. SALVAGE FOR RE-USE. ASSOCIATED OUTLETS 4 SWITCHES). SALVAGE DOORS FOR RE-USE. SEE PROPERTY 15. REMOVE EXISTING EVACUATION SIGNS. TENANT TO REPLACE. 0 DOOR KEY. SEE A-100 4 A-200 MANAGER FOR STORAGE OF EXCESS SERVICEABLE DOORS 4 FRAMES. SEE FLOOR 31. WOOD CORNER GUARDS TO BE REMOVED. PLANS 16. REMOVE 4 SALVAGE EXTERIOR BLINDS WHERE WALLS REMOVED OR ADDED 4 NEW BLINDS WILL BE REQUIRED. SEE FINISH LEGEND/ PLAN. 32. REMOVE FLOOR OUTLETS THROUGHOUT NEW WORK AREA IN SUITE 500. SEE 3. REMOVE AND SALVAGE EXISTING PAPER TOWEL DISPENSER AT BREAKROOM, FOR ELECTRICAL. PROVIDE FIRE SAFING IN FLOOR PENETRATIONS EQUAL TO FLOOR RELOCATION. Il. REMOVE ALL INTERIOR SILVER COLORED MINI-BLINDS A INTERIOR SIDELIGHTS. RATING. SEE A-000. SALVAGE FOR LANDLORD IF DESIRED OR DISCARD. 4. FIRE EXTINGUISHER 4 CABINET TO REMAIN AS-IS. 33. REMOVE AND SALVAGE EXISTING PURELL DISPENSER AT BREAKROOM, FOR IS. EXISTING MDF WINDOW SILL 4 CHAIRRAIL TRIM TO REMAIN, WHERE OCCURS. RELOCATION. ■ n E 5. REMOVE ALL FLOOR FINISHES (VCT 4 CARPET TILES) 4 RUBBER BASE THROUGHOUT "' ^ c°) REMODELED AREA. SCRAPE/ BUFF ADHESIVE TO PREP FLOOR FOR NEW FLOOR 19. REMOVE AND RELOCATE CARP READER SEE FLOOR PLAN FOR NEW LOCATION. 34. REMOVE 4 SALVAGE CABINET FOR RELOCATION. SEE FLOOR PLAN NOTE 30. Q a .0- PATCH WALLS AS REQUIRED. •-- C v FINISHES, THROUGHOUT. N 6 2 35. (E) CENTENE CARPET/ BASE TO REMAIN WHERE NOTED. PROTECT DURING CONST. OR (I) d tO c 6 6. EXISTING COLUMNS TO REMAIN. U.O.N. 20. REMOVE EXISTING CASEWORK (AND ASSOCIATED PLUMBING FIXTURES, OUTLETS 4 REMOVE 4 PROTECT FOR RE-INSTALLATION. n} - . n n2 SWITCHES). w • tien i. 1. SEE DEMOLITION REFLECTED CEILING PLAN 4 DEMO MEP PLANS FOR ADDITIONAL 36. REMOVE 4 SALVAGE CENTENE CARPET TILES FOR RELOCATION. • . INFO. 21. REMOVE AND RELOCATE EXISTING FURNITURE. SEE FLOOR PLAN FOR NEW U vv E LOCATIONS. 31. REMOVE RESILIENT FLOORING. S. REMOVE ALL OBSOLETE WINDOW DECALS 4 INTERIOR ROOM ID SIGNAGE. - x TD 22. REMOVE AND RELOCATE EXISTING EQUIPMENT TO NEW PRINT ROOM. SEE FLOOR 38. REMOVE WALLCOVERING 4 PREVIOUS TENANT SIGNAGE h� LOBBY. -,F2 t7 a 4 S. EXTERIOR BLINDS TO REMAIN, UON. PROTECT DURING CONSTRUCTION. VERIFY EXT. PLAN. o BLINDS THAT ARE DAMAGED 4 REQUIRE REPLACEMENT. • 35. REMOVE WOOD BASE AT PREVIOUS CORRIDOR. Z -173 23. REMOVE EXISTING IT RACKS. 10. EXISTING CASEWORK, SINK, GARBAGE DISPOSAL, SOAP DISPENSER 4 DISHWASHER 40. REMOVE WOOD CASINGS AT DOORWAYS 4 PREP FOR NEW PAIR OF DOORS. VERIFY TO BE REMOVED IN BREAK ROOM. SALVAGE REFRIGERATOR FOR REUSE. 24. REMOVE 4 SALVAGE EXISTING FIRE EXTINGUISHER SEE FLOOR PLAN FOR NEW CLEAR WIDTH AVAILABLE. SALVAGE WOOD TRIM FOR POTENTIAL PATCHING. '�Fn LOCATION. ..c ""' ' Q 11. REMOVE PLYWOOD FROM (E) WALLS AT FORMER SERVER ROOM. 41. RELOCATE POWER I DATA FEEDS SERVING EXISTING MODULAR FURNITURE TO HEA1H H. LARSEN 25. REMOVE EXISTING WHITE BOARDS. NEAREST WALL OR COLUMN. (PROVIDE NEW FLOOR OUTLETS WHERE REMAINING �f 12. REMOVE (E) VINYL WALL COVERING AT COMMON CORRIDOR I PATCH HOLES IN GYP. FURNITURE IS AN "ISLAND"). SEE ELECTRICAL PLANS. R '�'{ BD 26. RETAIN (E) PLUMBING ACCESS PANEL. ROSEVILLE, CAUFORNIA2 42. REMOVE 4 SALVAGE S.S. REFRIGERATOR FOR RE-USE. c. , ARI-11465 (3- 13. 13. RETAIN WOOD' PILASTERS, WAINSCOT BASE 4 CASING 8 ELEVATOR LOBBY. 21. EXISTING SHAFT TO REMAIN. MINIMIZE SIZE AND REPAIR WALL FINISH. - q��02-31-188 28. EXISTING ELECTRICAL PANEL. �i W LIMIT OF WORK (SUITE 500 EXPANSION) EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 (HATCHED AREA) 7` Z 00 ED 0 0 0 0 �o 0 0 0 z o xil . z - �' L_ " t5 I ' C f.. • , n . ,,,' ..:-.J riLii Z R §t:1 II, .1t, . 0 U 0 E...,.. . , 1(1-0-3 - I0 - 0 r.11. .a C A r . II a m nI InI D II II L] 0. % `1 ,1 d1 7.I illi II 0 � 1 _ - - - - 0 ____ � OTYP. _ 0 29 ® 29 TVP. � c- TCR / 0 o TYP. o = - - - - - 1. _ - b SIIm II 36 35 0 dp / Z @.1 Q II ® I o - - 0 E2 I I I� ND 1 I is € cR I 0 I #a 20 1 20 - - - _ _ 1 1 0 13 000 -o X imm\s„. /\ r r 2_1 L __I LF?:r . 2 Eit • 0 0 , a • , 0 n ice, ... ily 1,1 ..... ., ti 0 4_,,,..„ _ _it w___B? _ _ _ _se_ ____,i-c,,,,,-, _i.e . , e. .,r-E s_ hi, ,11, ,,,, . ., , -r-, k-a' jr- 6 0 ' o 000 o - 0 COQQ 1 T1'P. TYP. �' m. l i 1 l + as Er.::::i .';'::'::::'::1::1::1::1::1::1::1::::1::-i..i:EII:ELL' III"'"'"'"'"'"'"'!"!'"'":'""'"i'l.'.::11 ��,- F \ , ., .., , • 1 I2 , . a. i ii ., , o ( -\ lit-t7,-,--':. 8 'a • w�1 CI I" lav....... .... IX 1 � � R �.. ... .`..i - L r� ,_. � ../ .. : ,Kr 7. - -7) oft 1 -0 C _ II z < P ® 1II 1 �` Cli)wiL O I 1 - ' r' 0 i 5r 5 , ,ars- L IIII I , ` � $,T ' I {qX i r - 5433 a�]Box �y 3 (2g 111 �--� J 4 ° I J J 0 •Q Q ®mm e 0 7 _ o •ip. ••• • ® o 0 0 8 obil ,IIL - 1 0 .... I I C) V- _ I11 0 M EREc 'Tali 1 7 IT I clr /\ ri'Lm' ® o I1 2 at :i 41 35 AU -1 0 0 4 I I U r O can T 0 0 CO 0 I V+8 0 0 01 - \ _ __ - I 1 b 30 TYP. _ _ TVP. N 1 0o� O 20 �� �� �� �I- ��1 IL - - b 11 11 II III L � � JTF---, �oO \\ A\/ '� - - � III O - _ -B, ,,,, ; ,+�1 1 N II II I I (�o ~ 1 +8 +s ® - �� v 11 11 11 11 LCR >, 11 25 11' II II 35 I If11 0 � " oOGOIr 0 I TVP. 1 II II II IJ O �i I TVP. 1 0 29 2 29 2 II II II II o o � ;' o - - 11 0 . I 11 II 11 II I7„.-- II ' &I II II II II L _ _ I-I$ 7_ g_�J®I _ss: _ CO I 2 - _ _ _ �� �. 0 11 11 H I1 I \Il -j 1 f II LL_---II=---11-_-,lJ 35 11 0 I - � 1 ° II 1 '-' rlid Cil) II A -EL 14113 L c' 0 .7 '- 7 . 0 1 __I 3Z �� 35 35 Q ,, . CD �0 0 0 0 035J 0 35 L O TYP. 0 � � � 0 ® s CD - - - I - i44 + 41 - � � � Z j I I_ 1 To : `� '� � Y - - VE:1 o II `L >Deea� Y a� Y A Y Y Y , II 0 TYPICAL NOTES EEail cl < > 6 •o•00000 : , >./-<> 0,ti „,,,,„ ... . ::::3LYM />/-< - 0 ....... F;;;;:i Eli :::::::. , ,,a, 42 CD DATE ; i0oN -fel0 � ti 05/23/2018 ED 0 0 oir o . „, �1 ` �� ---- O �/ o 0 SCALE AS NOTED ll' EXISTING SUITE 500 TO REMAIN - HATCHED AREA MGR HHL J LIMIT OF WORK (SUITE 500) P EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 (HATCHED AREA) L J0O cENa14 / SHEET 0 DEMOLITION PLAN A-100 SCALE : 1i8�� . 1 -0 . , , • OF SHEETS HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NIDI TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIiSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. REVISIONS BY FLOOR PLAN NOTES DET4!LS STI"E3OLS LEGEND 05/23/18 0 ALIGN.FINISH El EXISTING COLUMNS a EXTERIOR WALLS TO BIDSET/ PC 16. SEE A-200 FOR DOOR LEGEND 4 A-6120 FOR EQUIPMENT LEG'ND. 29 ADD SEALANT BETII.EEN WINDOW SILL 4 MILLIONS • CURYED WINDOW SECTIONS NOTED- REMAIN 2. SEE A-600 FOR ENLARGED BREAK R'JGi'1,MOT'-ERS R1`1, 4 PRINT ROOM PLANS 4EXISTING WALLS TO REMAIN CASEWGRC ELEvATIONS. 11. WORK STATIONS(BY TENANT)SHALL HAVE AN ACCESSIBLE WORK CANTER CR BE 30. RELOCATE RASE CABINETS FROM OLD COPT ROOM. ADD NEW CCUNItt1'1'OP, BACK.SPLASH, ADJUSTABLE TO ACCCJ"i'1ODATE EMPLOYEE NEEDS. 4 RIGHT-HMD END PANEL 12/4-100 r 1 EXISTING FULL 1-IEICsHT WALL OR SEE PONT' WALL 3. ALL ITEMS NOT INDICATED OR NOTED ARE (E)TO REMAIN AS-IS. 14/4-1100 DETAIL 14/A-100 IF NOT FULL HEIGHT. 18 EXISTING SHAI=T TO REMAIN.MINIMIZE SIZE. 31. EXISTING DOOR A55'(. TO REMAIN AS-IS, 4. PATCH AND REPAIR WALLS W4-1EIRE WALLS OR OTHER CONSTRUCTION REMOVED,TYPICAL 13/4-100r NEW CEILING HIGH WALL TH 4OJT SUITE- Ie. RELOCATE WALL-MOUNTED TV FROM PREVIOUS BREAK ROCK PROVIDE BACKING IN WALL 32. VERIFY FLOWER 4 DATA FEED FOR(E)PJRdNIT'JRE CLUSTER PROVIDE NEW. AS REQUIRED TO SUFPORt WALL-MOUNTED TV. 12/4-100 NEW FULL HEIGHT WALL 5. (E)STAIRS TO R'''AIN A5-15. 33. AT SECURE WALL LOCATIONS WIRE DUCTING IS CONFLICTING, INFILL GAPS BERIEEN WALLS/ 20. VERIFY ACOUSTICAL SEAL IS CONTINUOUS WITHOUT GAPS AT WALL-TO-MILLION JOINT- CEILINGS 4 DUCTS WITH IARC JARS CLOTH CN MEL. STUDS TO WITHIN 4" OF OBSTRjCTIONS. 0 DOOR 4 HARDWARE KEY. SEE A-200C ■ E 6. RELOCATED P URELL DISPENSER IE-SEAL IF ANY GAPS EXIST EYP. AT ALL EXISTING CONDITIONS. m i o CR CARD READER (NEW U.ON.) 'J J O a .o 'NIDE IDE BACKING IN WALLS A5 REQUIRED TO SUPPORT NEW WALL-MOUNTED EQUIPMENT, 21. ALL R�,IIRNISHINGS SUrtJLIED AND INSTALLED BY TENANTS VENDOR,U.ON.ELEC. •- g FURN/TURE, CABINETS 4 HVAC EQJJIPI`1ENT,EYP. CONNECTIONS BY GC. V „ M n 0_ a� 22. EXISTING FIRE E)CTINGUISI$R CABINET W/ ABC FIRE EXTINGUISHER TO IET1AIN, WITH FIRE S. (N)ABG FIRE EXTINGUISHER IN SEMI-RECESSED CABINET W/1=1k�MARSHAL APPROVED Q cc n n a SIGNAGE ABOVE. SEE 4/A-1�FOR MOWTIN!s HEIGHT. MAR 41.-APPROVED SIGN ABOVE. VERFY MOUNTING HEIGHT MEETS I.EQUIRET ETITS ON i� - 4/A-100 FOR PR:711DING OBJECTS. i.-',":.-; E 9 REQ'WALLS SHALL WAVE LEVEL 4, SMOOTH TF=XTUR7 UON1 FLOAT EXISTING WALLS AS 23. INFILL WALLS U,HIERE DOORS 4 FRES ARE REMOVED, EYP. m = X - 10- SEE SHIEET A-100 FOR ACCESSIBILITY REQUIREMENTS. 24. FIELD VERIFY WALL I-EIGHTS ABOVE CEILING. F RIDE CLOSURE PONY WALLS ABOVE L �o Z EXISTING, IF WALLS AIE NOT RLL HEIGHT 4 SECURE WHERE NOTED. SEE WALL SYMBOLSZ Q 11. SEE FINISH LEGEND AND FINISH PLAN 4-400 FOR NEW FINISH MATERIALS. LEGEND,TYP. AT SECURE= ROOMS. ■ T 12, ALL DOORS SHALL COMPLY WITH' 12/A-200 4 1/A-100. ALL DOCS ARE TO REMAIN U.ON_ 25. EXISTING FULL HEIGHT WALL .ctftED " DEEP PHONE BOOTH COUNTER SEE DETAIL 14/A-501- '�C NEA i ER H.444-10013. ALL ACCESSORIES, WALL MOUNTED ITEMS, HARDWARE 4 GCNT13�L5,ETC.SHALL C.GR"ff'LY fill 26. NEW 20 ; --1 4/A-� 21. RELOCATED REMOTE DROP DOJ' EJECTOR SCREEN FROM 1 CEILING, SEE RCP. >••,; 14. RELOCATED OR NEW EVAG BOX BY TENANT. ROSEVILLE, CALIFORNIA , 28. NOTIFY AIa:H11TECT IF NEW WALL OVERLAPS SIDELIGHT (53,4 ARI-11468 O 3. 15. SEE FI FGTttICAL DRAWINGS FOR POLER 4 CO'11.NICATIGN REQUIREMENTS 4 LOCATIONS. ,9,' EXP.12 31 18 OF UQ`V W LIMIT OF WORK (SUITE 500 EXPANSION) MF y ,k EXISTING SUITE 520 TO BECOME 4 PART OF SUITE 500 (HATCHED AREA) II.Z 8�^ W 0 0 0 CD () �_ r_,_ 0 0 C.) 0 o 8 oTYP. ------(%. W J � - '"- " # # it- If , . .. 0 A CbdD db . a db C' o a W L., . J OIIGE �� 11-1--r.---4. 532 Errij "'*-71 Er-1] C -� ." 4 I� " 6. C - e r ,,, 5N _ L 1„.. ,1 r- ili..........1 , - 17 ��11 f' 15 i: . .D . ..: a_ . . , ,,, . , �� ' "'.I o �'.'7c � 00 o ���1 r o / {� ' f'�r �, i s - I J o d o 0 i=' f 41 [C01 - WO TION - _ ...................._„� j P IITT- _ = ,, 1 �i o 502 1 �,.. C .. .. J - I C� 501 a = \-� ti r ID 40 N 5' 2 - - Y Y_ "EI IIS__ B 9 9. o I ll p pt z.ns�r C A D �p�� I I I ,_ 03 �� _ I,. , ` ( C:\.3 0-700 Com] CHI=F.'- t--'] -8.. C .a � 0 3'_S.. F7 D '' Com] p ., 8'-11" OPEN OFFICE 1 I®Tl'P.- ri 508 OFFICE45, f - x-I MIN. 11.-4a-,Pr o o MIN. �� �� ® ,�Y z MIN_ © p , 0 531 P,i-m_14 I CR IEE) Z O1_311 - OFF' CITYP- 6i FE� 8' " 81410'-52 10'-5i11 11' li" CE ¢ o Et) - C. ,, y �' 533 ' +/-52" 6' Q io NON-RATED COR�?IDOR x ■■ 3' ..rt ,� . _ 3r HUDDLEr , i 01.. 1 2 ®. F4 5551. `� chi E '4 © \ C)r.'7:. WE I-I 4P 5® 536v `r r- U �"I�� �� sag 510 7 fl o OFF' 12 - �--' r' :11111 (NVK 39> Pt. . ll L- �� 504 505 50� / ' x - 12 E 539 26 , 3i .. c.i. 530 �� �j - 1. 86 + i►��1 gee same L-; �� G �� CR Ire ... ,.,...,.,,,,,, c'r� till�YCV Nt �'' :...:::::::::::::.:::: .,:,..:: .: _ +'4 I. • 0,....a o- 53aJA \ ELE - PRINT I ` ., p r = �/ I 511 GT T ' 0 EQUIP I § 0) .. 0 C 9 C ,mac , , .- I `t ST T 5 6 �� / ..„. (A .. _ c) . ,..- O [ ---_ ST,41R-1 ` 1, STAIR 2 O C Z° -I 6 W C] I ! 7T-e-DNi C 9 1 �l.E1/AT cR M( 1 I ! I in- cc 6 -3 " I I I 0542 \ ` f LL LI : ®D D 14 m0 D I m m -I 4) : o } L • 0 -•- ' 4, v.. �........, :� 5Q3 U _- r u` F D I + �° p 5 e" ,� _ •�l. : 5k ILI - \ o�� NON-RA coRRl �x 11 (1) ' ^�� io m . - ® ® CIRC ( IC �� �� ° 1� 6'-'1 I�� F `� 540 �,i � I IJLI .;, 1 C) ' - CR .�/ CO , FE 1 180 OPEN OFFICE 3 CI Ca z 6'-3 �� 4'-4 " 5'_21IC) /� 528 +/-9'-104" +/-9'-l0l" +/-9'-104" E / 0 ' 113t-. r1.1LTI-FUR=OeE CO 4 4 d' 3 // p J EYP. it' 60" yletroll - %in z 1 01- .....-""" 81 lir 01 24 4. MIN p _ Igo r (- 0 :.,,, EP :in Li . I : CRV 3� +Yu LI -IP (o \ , , C) Cran 7: �[1� I and I �_ ,3'_8.. ®� LSI ® m� i �� 0 I 4,!1 [ 11 ;C) 'ill [1:1] ri ' Cj CD CI C19 11 C . m� cR ;a 541 © - , �, _ (N) 0 1.� . .ir . , ,, .., , ..... U I ® ®SIJ IW 0 , �� 0 IT T MIN. - I ? II I °� . 'r 11] Im ®� _ It 5'-2 " 6' 8.. 523 IFI I C # Cn nj rt TRAIN ia 1 t fr'- C'2 r U ' CCI +/-10'-94c �1 _.-._ ! _ �° <><> OI*'ENO� IGE 2C) Q l_ CA [is:, i �1 1�'-i"+/- �I �,, RAI I ' Qp9DI0-y 3 C .� 1011 I � 7c),_ 31 _ OFFICE 11 � 0 31 '1P:., m P ,. ___ . ,,_ 1 ===r EEO ."41• . all. r (1) I I tl I■I I t l I I■I :; CC 8 ! �. �� 0 4 I I ' OFF' _ - OFFICE -I i -700 529 I520 •- 10 OFFICE 9 25 5 I I I _._. I � � ' t o Z C,1=---) 526 I I I I I C I ` 1 ® ■ ■ ■iI :I i I IS - 0 • CC .i!:1:1•N) ) 1 . .d 11 11 0 1 - _•.jj I L-J i - ... .......... ... 111 _ 6 rt ima .,::., , : .,: ....... ...... .Mil :14- I Ell D -' , -_.Et_ - + tom LL ', , . I, -, : ti, u. i, - ,., ir.:=t u 0 ., ' , -:-- -0---, -4" --- 1 iffiti m --ij,,, g -., +T i I�I .k . .. ,..:... II-91 (.4 .<>/ -, ?i- CC ( .E1) i I, :' . :,i..::' .. ..,::•,,.,. ...:,;.,,!.L.. 1-.. ...x-Ilf 1 c=1-4„...4_.q 4.......i.. 1 1 ...,.. 1,. -'- 0 TY-f GAL NOTA ' 7 0isi■I i■i i I i■7 111.4......4_1i p - 000000 . ifil sti. I LL 000000® , 0 \1ED '0 :::1.1 in 1 601514 " 5'-5" 13'-4" DATE p y' sc,k 'n +� / / 05/23/2018 0 0 0 0 0 _ __ _i- 0 o o SCALE AS NOTED 1' EXISTING SUITE 500 TO REMAIN - HATCHED AREA, U.ON. MGR HHL / LIMIT OF WORK (SUITE 500) EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 - HATCHED AREA, U.ON. / JOB CEN014 / SHEET 0SCALE : 1/8FLOOR + FURNITURE PLAN A-1O1 " = I -0" \ , , OF SHEETS HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE +7 TO BE REPRODUCED, CHANGE° OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. : ::::::::>< REVISIONS BY . .... . . . D ." .rm. ...._..... ., . ....... ....... • .. ... . ........ .............•• .....•....... ...........................................L.,2001RSci-1 , ..i.all.1 I. „:, i _ ::::::::::::::::::::::::::::::: ::: :�:::: :: :::::::::::::: ::::::�::::�::� : :: D00R 8c HARDWARE G NOTES ::::::::::::::::::.. :... ::::::::::::::::::::: : HARDWARE GROUPS >:>_:.... 05/23/18 DOOR/ REMARKS/NOTES: ST - STEEL GROUP 1 - PRIVATE OFFICE/ CONF ROOM (PASSAGE) 0. PROVIDE SOLID BLOCKING OR STRAPPING IN WALLS BEHIND WALL BUMPERS. BIDSET/ PC FRAME N=NEW AL = ALUMINUM (4) PLAIN BEARING HINGES 51ZE DOOR FRAME STATUS SIDELIGHT R=RELOCATED GL = GLASS (1) LEVER HANDLE PASSAGE LATCHSET 2. REUSE SALVAGED METAL DOOR FRAMES FOR NEW LAYOUT.REPAIR ANY DENTS BEFORE PAINTING, E=lEXfSTING ANDD = ANODIZED (ll FLOOR MOUNTED DOOR STOP TOUCH UP DOORS FROM GOUGES AND SCRATCHES.PROVIDE ADDITIONAL METAL FRAMES AS NO. ROOM REQUIRED PER FLOOR PLAN.RATED DOORS MAY BE RE-USED AT LOCATIONS WHERE RATED DOORS 55 = STAINLESS STEEL (3) DOOR SILENCERS N=NEW ARE NOT REQUIRED,CONTRACTOR TO VERIFY WITH PROPERTY MANAGER HOW TO STORE ANY O R=RELOC MTL = METAL (1) COAT HOOK - CENTERED ON DOOR, MOUNTED INSIDE ROOM REMAINING UNUSED DOORS. SEE DEMO I NEW FLOOR PLANS FOR DOOR COORDINATION WxH TYPE RATING HARDWARE TYPE MAIL. FIN. E=EXIST'G LU H RATING PL = PLASTIC LAMINATE GROUP PT = PAINT GROUP 2- PASSAGE DOOR (W/ CLOSER) 3. CONTRACTOR TO COORDINATE KEYING WITH rrwrtre.i r MANAGER AND PROJECT MANAGER ALL (4) PLAIN BEARING HINGES KEYS ARE TO SE KEYED TO THE BUILDING MASTER AND THE TENANT SPACE PLACED ON A TENANT 501 3'-0" x 8`-0" A - I A ST PT R/R I +/-23" 8'-0" CONF. - 501 NOTE 25 (1) LEVER HANDLE PASSAGE LATCHSET SUB MASTER FOUR COPIES OF THE TENANT SUB MASTER SHOULD BE SUPPLIED TO THE TENANT. (1)FLOOR MOUNTED DOOR STOP 522 3'-0" x 8'-0" A - 2 A ST PT R/R 1 +/-23" 8'-0" BREAK - 522 NOTE 25, 21 (3) DOOR SILENCERS 4. DOOR OPERATING DEVICES SHALL BE CAPABLE OF OPERATION WITH ONE HAND AND SHALL NOT „ „ �, REQUIRE TIGHT GRASPING,TIGHT PINCHING OR TWISTING OF THE WRIST.ALL DOORS SHALL HAVE ADA ■ r E 522A 3 -0 x 5 -0 5 - 1 5 ST PT R/R +1-23 5 -0 MULTI-PURPOSE ROOM - 522A (1) CLOSER COMPLIANT LEVER HANDLES UNLESS NOTED OTHERWISE. 6 3 5225 3'-0" x 8'-0" A - 2 A ST PT R/R +/-23" 5'-0" BREAK - 522 O a 6 GROUP 3 - POCKET DOOR (PASSAGE/ PULL) 5. ALL MEANS OF EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE WHICH EGRESS 15 TO 'LT: o (1) POCKET DOOR CAGE 4 OVERHEAD TRACK BE MADE WITHOUT THE USE CF A SPECIAL KEY OR SPECIAL KNOWLEDGE OR SPECIAL EFFORT. W 6 2 r° 5234 PR. 3'-0" x 8'-0" C - 5 C 5T PT N/N I 20" 8'-0" TRAINING ROOM - 523 (1) INVERTED STOP V) }' N `(' j � 5235 PR. 3'-0" x 8'-0" C - 5 C ST PT N/N 20" 8'-0" TRAINING ROOM - 523 (2) C-PULLS 6. ALL CLOSERS SHALL MEET THE REQUIREMENTS OF THE ADA AND IBC (MAX OPENING FORCE 15 LBS. A 1 C � �;, �;a , AT INTERIOR,5 LBS.AT EXTERIOR DOORS). SEE 15/A-100. W oS r N 5230 3'-0" x 8'-0" A - 60 B 5T PT N TRAINING ROOM - 523 (E) ACCESS CONTROL HARDWARE 4 CLOSER GROUP 4- EXIT STAIRS ALL DOORFABRICATIONN °G n N R 1. FIELD VERIFY SIZES PRIOR TO AND INSTALLATION. 0 L . e o -c- 529 HARDWARE TO REMAIN EXCEPT CHANGE LATCHSETS TO LEVER HANDLED .) 'Fr) O73E 529 3 -0 x E3 -0 A - 1 A 5T FT R/R +/-23 51-0" OFFICE 11 - 529 NOTE 25, 21 CONFIRM STOREROOM LOCKSET. 8. CIRM THAT ACCESS CONTROL SYSTEMS ON ALL (N) 4 (E)DOORS COMPLY WI ALL APPLICABLE ' E 530 3'-0" x 8'-0" A - I A ST PT R/R +/-23" 8'-0" OFFICE 12 - 530 NOTE 25, 21 • ADD LATCHGUARD 4 NRP HINGES e STAIRWELL SIDE OF DOOR BUILDING CODES. l > ;� E. E = a 0 531 3'-0" x 8'-0" A - 1 A ST FT R/R +/-23" 8'-0" OFFICE 13 - 531 NOTE 25, 21U t7 a `` 1 GROUP 5- PR TRAINING ROOM DOORS 9. ALL HARDWARE FINISHES TO MATCH BLDG. STD.('1625 BRIGHT CHROME PLATED)FINISH LEON.HINGES, L c a 5toP5,CLOSERS,STRIKE PLATES, COAT HOOKS MAY HAVE SATIN CHROME FINISH. Q 532 3'-0" x 8'-0" A - I A ST PT R/R +/-23" 8'-0" OFFICE 14 - 532 NOTE 25, 21 (2) 1 PR BALL BEARING HINGES mn . ; (2)3 DOOR SILENCERS13 535 3'-0" x 8'-0" A - I A ST PT R/R +/-23" 8'-0" HUDDLE 1 - 535 NOTE 25, 21 (2)DOOR CLOSERS 0. ALL KICK PLATES TO BE INSTALLED ON THE PUSH SIDE OF DOOR MFR: ROCKWOOD,SIZE: 8"x34", (2)FLOOR MOUNTED DOOR STOPS FINISH; MATCH EXISTING TENANT HARDWARE FINISH. 536 3'-0" x 8'-0" A - I A 5T PT R/R +/-23" 8'-0" HUDDLE 2 - 536 NOTE 25, 21 (2) 10" 'C' PULLS x 625 II. ALL COAT HOOKS TO BE PER TENANT SPEC,MOUNTED AT MAX 48" AFF.(AN ADDITIONAL HOCK MAY .cSfeD`' it! 531 3'-0" x 8'-0" A - I A 5T PT R/R +1-23" 8'-0" HUDDLE 3 - 537 NOTE 25, 21 (2) 10" x 3" PUSH PLATES x 625 BE ADDED AT +12" IF DESIRED).ALL COAT HOCKS TO BE INSTALLED ON THE INSIDE OF ROOM. • WHERE (E)COAT HOOKS OCCUR ON REUSED DOORS THAT DO NOT REQUIRE COAT HOOKS,REMOVE 4 HEA 1' H. LARSEN 538 3'-0" x 8'-0" A - 60 B ST PT R/R STORAGE - 538 (E) ACCESS CONTROL HARDWARE 4 CLOSER GROUP 60 - AGS DOOR (SINGLE W/ ELEC. LOCK - FAIL SECURE) FILL HOLE TO MATCH DOOM'COLOR(E)COAT HOOKS TO REMAIN ON DOORS THAT REQUIRE COAT _ f; (3)HINGES WITH BALL BEARINGS (NRP AT OUTSWINGING SUITE DOORS) HOOKS 4 ARE ACCEPTABLE AT PRIVATE OFFICES,CONFERENCE ROOMS,STORAGE ROOMS 4 UTILITY r.-. 539 3'-0" x 8'47" D - 3 D 5T PT N/N PHONE - 539 (I) ELECTRIC TRANSFER HINGE ROOMS,PROVIDED THAT THE HEIGHT IS WITH IN THE ACCESSIBLE REACH RANGE- •` ROSE 1LLE, CALIFORNIA= 540 3'-0" x 8'-0" A - 60 B ST PT RM MOTHER'S ROOM - 540 (E) ACCESS CONTROL HARDWARE 4 CLOSER (1) LEVER HANDLE ELECT. LOCKSET (FAIL SECURE) 12. ALL DOOR FRAMES AND CABINETS SHALL HAVE SILICONE SILENCER TABS OR 51=ALS. - N� ARI-11468 0 (I)FLOOR MOUNTED DOOR STOP EXP.1231-18 541 3'-0" x 8'-0" A - 60 B ST PT R/N STORAGE - 541 (E) ACCESS CONTROL HARDWARE 4 CLOSER (I) SMOKE SEAL (IF REQ'D BY CODE) 13. PROVIDE NRF'HINGES AT OUTSW€NGING TENANT SUITE DOORS. REPLACE (E)AS NEEDED.ALL SECURITY 9T$. OF C'C' (3) DOOR SILENCERS DEVICES,HARDWARE, 4 ROUGH-INS INSTALLED IN ADDITION TO 11E1E5 LISTED IN DOOR SCHEDULE/GROUP. 542A PR 3'-0" x 5'-0" E 20 MIN, 10 C 5T PT N/N ELEVATOR LO$i3Y - 542 FAIL SAFE (I) DOOR CLOSER 542$ PR 3'-0" x 8'-0" E 20 MIN. 10 G ST PT R/N ELEVATOR LOBBY - 542 REPLACE LOCKSET, FAIL SAFE (I) STRIKE LATCH GUARD (OUT SWINGING DOORS ONLY) 14. ALL GLAZING IN HAZARDOUS LOCATIONS SHALL BE ICI ircrctU OR SAFETY GLASS AS INDICATED (I) BADGE READER, MOTION SENSOR, DOOR CONTACT - PROVIDED BY OTHERS WITH 'T' ON WINDOW AND DOOR ELEVATIONS. 543 3'-0" x 8'-0" F 60 MIN. 4 F ST PT E/E STAIR 2 EXIT ONLY • REFER TO ROUGH-IN DETAIL FOR HARDWARE AND ROUGH-IN INSTALLATION LOCATIONS/ SPECIFICATIONS. SEE ELEC. PLANS. 15. REPLACE WEATHER STRIPPING ON ALL EXISTING AND RELOCATED EXTERIOR DOORS.(NOT USED) Z 544 3'-0" x 8'-0" F 60 MIN. 4 F ST PT E/E I STAIR 1 EXIT ONLY • IN THE EVENT LOCAL CODE REQUIRES THE USE OF FAIL SAFE 16. CONTRACTOR 15 RESPONSIBLE FOR SELECTING DOOR STRIKE FACEPLATES COMPATIBLE WITH c :: 0 DOOR STRIKES CONTRACTOR TO PROVIDE AND INSTALL: (1) NES HARDWAREQ g HARDWARE LISTED IN DOOR SCHEDULE/GROUPS. ALL (INCLUDING SECURITY DOOR �� 2005M3 SMART PAC III. HARDWARE 4 ADA HARDWARE)AND ROUGH-INS TO BE PROVIDED I INSTALLED BY CONTRACTOR Z E O GROUP 10 - ACS DOOR (DOUBLE DOOR STRIKE - NO INTERCOM)- FAIL SAFE 11. ALL CONDUIT WILL BE CONNECTED TO JUNCTION BOX AND RAN TO DEVICE/HARDWARE LOCATION. Lir J 2 (1) HINGES WITH BEARINGS (6 HINGES FOR 1' DOORS, 8 HINGES FOR 9' DOORS, NRP m W OUT-SWINGING DOORS) 18. ALL CONDUIT WILL CONTAIN A PULL STRING FROM JUNCTION BOX TO DEVICE/HARDWARE LOCATION. 0 D (I) ELECTRIC TRANSFER HINGE 19. ONLY THE SPECIFIED DEVICES AND HARDWARE LISTED ARE APPROVED FOR USE.NO SUBSTITUTIONS 0 z 8 (2)FLOOR MOUNTED DOOR STOP ALLOWED UNLESS REVIEWED 4 APPROVED BY CLIENT OR ARCHITECT. J (2) SMOKE SEALS (IF IREQ'D BY CODE) la (2) DOOR CLOSER 20. ADD METAL VENTILATION LOUVER AT BOTTOM OF SERVER ROOM DOOR, IF NOTED FOR MAKE-UP AIR U (I) SET AUTOMATIC FLUSH BOLTS ON MECH'L PLANS. PT.FINISH TO MATCH FRAME. (I) ASTRAGAL - C.,:4 r (I) COORDINATOR 21. SENSOR RELEASE OF ELECTRICALLY LOCKED EGRESS DOORS SHALL COMPLY WITH IBC 1010.1.98. (I) 24V FAIL SAFE ELECTRIFIED MORTISE LOCKSET (I) BADGE READER,MOTION SENSOR, DOOR CONTACT - PROVIDED BY OTHERS 1)SENSOR INSTALLED ON EGRESS SIDE,TO DETECT OCCUPANT APPROACHING.DOORS UNLOCK BY • REFER TO ROUGH-IN DETAIL FOR HARDWARE AND ROUGH-IN A SIGNAL FROM OR LOSS OF POWER FOR SENSOR D 0 0 R TY P E S/ FRAM E TY P E SINSTALLATION LOCATIONS/ SPECIFICATIONS. SEE ELECT. PLANS. • CONTRACTOR RESPONSIBLE FOR ALL DOOR CORING AND FRAME2) LOSS OF POWER TO THE LOCK SHALL AUTOMATICALLY UNLOCK THE DOORS (FAIL-SAFE) PREP REQUIRED FOR TRANSFER HINGE. 3)PROVIDE A MANUAL UNLOCKING DEVICE (PUSH BUTTON) 40"-48" AFF., 4 WITHIN 5' OF SAID DOORS.SIGN "PUSH TO EXIT".PROVIDE CLEAR ACCESS. DEVICE SHALL DIRECTLY INTERRUPT 13 ITh 13 14 13 (173-\ 14 POWER TO THE LOCK OR CONTROLS 4 DOORS SHALL REMAIN UNLOCKED FOR MIN.30 SECONDS. A-200 A-2DD A-200 A-200 A_2Q0 A-2DD A-200 4.)ACTIVATION OF BUILDING FIRE ALARM SYSTEM,AUTOMATIC SPRINKLER SYSTEM OR FIRE 3' 2r 1 ,, 3' 3' J� JIB 6 t3'-6" D TILCTIACON S STED SHALLSTEM )S RESET. UNLOCK THE DOORS.DOORS TO ) MAIN UNLOCKED ZO j T I `J EI 22. ELECTROMAGNETICALLY LOCKED EGRESS DOORS SHALL COMPLY WITH IBC 1010.1.9.9.DOOR SHALL Z ..i. • 13 HAVE A BUILT-IN SWITCH THAT DOES ALL: Q A-200 0- GLASS 61' 6' VIEWPORT 1.) IS AFFIXED TO THE DOOR LEAF AND IS OBVIOUS 4 READILY OPERATED. W - I---TEMP. -,- \ ✓•- 2)OPERATION CAPABLE WITH ONE HAND. - tO \ \ GLASS 3)OPERATION OF THE HARDWARE INTERRUPTS THE POWER TO THE MAG LOCK 4 UNLOCKS THE DOOR , SIDELIGHT LD- C PULL 4)LOSS OF POWER UNLOCKS THE DOOR -I -I - I` 5)WHEN PANIC HARDWARE REQUIRED BY SECTION 1010.1.10,OPERATION OF IT ALSO RELEASE MAG LOCK co CV el N - I - N t ` e - CV T �t I I' �t ` T T `L _t II , OSI 6.)LOCKING 5TSTEM LISTED IN ACCORDANCE WITH UL294. EN �I 23" �r 23" �� ��/-20',� +/-20'�„ 23. ALL SECURITY DEVICES TO BE PROVIDED 4 INSTALLED BY TENANT OR ON BEHALF OF TENANT BY OTHERS. Z C) -I 6 U.ON. U.ON. 24. REPAIR MINI-BLIND SCREW HOLES IN WINDOW FRAMES PRIOR TO REPAINTMG. a"}' A OFFICE/ CONF. DOORS - SC WOOD DOOR Al- ENTRY DOOR - SC WOOD DOOR W/ B SINGLE DOOR - SC WOOD DOOR C DOUBLE ENTRY DOOR - SC WOOD DOOR W/ D POCKET DOOR - SC WOOD DOOR W/ d W/ CHERRY VENEER W/ CUSTOM MEDIUM CHERRY VENEER W/ CUSTOM MEDIUM W/ CHERRY VENEER W/ CUSTOM CHERRY VENEER W/ CUSTOM MEDIUM CHERRY CHERRY VENEER W/ CUSTOM MEDIUM 25. WHERE GLASS SIDELIGHTS ARE RELOCATED FROM CORRIDORS TO WITHIN TENANT SPACE,WIRE GLASS IS NOTA CHERRY STAIN W/ 1/4" GLR TEMP.GLASS CHERRY STAIN W/ 45 MINUTE FIRE MEDIUM CHERRY STAIN IN TIMELY STAIN W/ INTEGRAL SIDELIGHTS W/ CLEAR CHERRY STAIN W/ CLEAR TEMP. REQUIRED. REPLACE WIRE GLASS W/CLEAR TEMP.GLASS. 6 INTEGRAL SIDELIGHT IN TIMELY STANDARD RATED CLEAR SAFETY GLASS INTEGRAL STANDARD PROFILE BROWNTONE TEMP.GLASS IN TIMELY STANDARD PROFILE GLASS VIEU.IPORT IN TIMELY Z Q F 26. REPLACE ELECT.TGEE. RANSFER HINGE. PROFILE BROILNTONE PAINTED FRAME. SIDELIGHT IN TIMELY STANDARD PAINTED FRAME. PAINT FRAMES BROW'�IONE PAINTED FRAME. PAINT FRAMES STANDARD PROFILE BROWNTONE 3 PAINT FRAMES PT-4 PROFILE BROWNTONE PAINTED FRAME PT-4 (ON TENANT SIDE ONLY IN PT-4. PAINTED POCKET DOOR TRIM KIT. W Y 21 OR HM FRAME WHERE NEEDED PAINT MOTHERS ROOM) PAINT FRAMES PT-4 . REPLACE LOCKSET WI PASSAGE LATCHSET. OK TO RETAIN CLOSER :0 e Q FRAMES ESPT-4ONTENANTSIDE. (NOT HARDWARE SPECIFICATIONS O LEVER HANDLEDerEF PASSAGE LATCHSET: SARGENT 10LP x 15 x 625 LEVER HANDLED Cl) \ 6 OFFICE LOCKSET: SARGENT 10LP x x 625 iNLEVER HANDLED e) - ADD STOP IN DOOR POCKET TO wi ` �� �� � GYPSUM BOARD OVER STOREROOM LOCKSET: SARGENT 10LP x 04 x 625 W b x36 20W LIMIT DOOR OPENING TO MAINTAINMETAL STUD ELECTRIC MORTISE MIN. TEMP. GYPSUM BOARD OVER LOCKSET (FAIL SECURE): SARGENT 5200 ELECTRIC MORTISE LOCKSET 10LP x 211 x 625 CLEARANCE AT PULLS. m FR GLASS METAL STUD YLINDRICAL 5/8" GYP. BOARD cA ` LEAFCTIVE 3/8" 3/8" L RTRLOCKBET IPI (FAL SAFE SARGENT 10G10 LB 24V T405 STEEL CASING I7'rte f METAL FRAME ELECT. STRIKE: VON DUPRIN 4200 OR 6400 SERIES (7-4 �� METAL FRAME ), ,t - - FLAT STUD FRAMING AS REQUIRED = ___ 2r -------ELPLAIN BEARING HINGES: STANLEY F119, 4'i2" x 4'i2" x 625 co AT POCKET DOOR RECESS i '(y /' BALL BEARING HINGES: STANLEY FBB119 4112" x 41/2" x 625 MINIMAL 1. SLIDE-IN SEAL Q 112" MIN. GLR IN _ � (.1 A �� DIMENSION ELECTRIC TRANSFER HINGE: STANLEY CEFBB119 4'i2" x 4E2" x 625 �� CLOSED POSITION ELEVATOR LOBBY DOOR SG WOOD DOOR �,j 4.1 / ` BB/ NRP HINGES: :TEA5N1LcEoYF NBP/ FBB119, 4'/2" x 412" x 625 W E W/ CHERRY VENEER WI CUSTOM MEDIUM 0 CE �1i2" CLR/ �� 32" MIN. CHERRY STAIN W/ 6"x42" 20 MIN. TEMP.FJZ ROLL-IN SEAL GOORDfNATOR: 52 - FL20 US28 W r HEAD q �- SMOKE SEAL I��AD MIN. GLR CxLA55 e INACTIVE LEAF IN TIME=LY V� WHERJ= RJ^Q'D f/4" THICK CLEAR STANDARD PROFILE BROWNTONE PAINTED AUTOMATIC FLUSH BOLTS CCQ e ,--, FRAME OR HM FRAME WHERE NEEDED. PAINT TEMPERED GLASS 4 DP STRIKE: IVES FB 41P 630 W/ 481-4S9 0 FRAMES PT-4 ON BOTH SIDES. / n �3/4'y I /8" /� CLOSER: LGN 401DEL ALUMINUM 626 2 x \\ \ \ \�POCKET / DOOR LJ DOOR CI3 NEOPRENE SETTINGWALL STOP: fVES W5 401 CGV 626 a00EV BLOCK 3, / DOOR HINGE DOMED DDDR STOP: EVES FS 436 626 = J o J.-7 KICK PLATE: TRIMCO K6000, 13" H., SATIN CHROME US26D I " I . o �- FLOOR CLIP-SECURELY �_C-PULL ATTACH TO FLOOR ELECTROMAGNETIC LOCK: RCI MODEL 8312 W/ FILLER BARS, BRUSHED ANOD. ALUM.FINISH CC w STRUCTURE Et6 _ THRESHOLD: PEEKED SADDLE 5"-211D (OR EQ) O •I C -(ETEMP F R - - SMOKE AND DRAFT SEALS: PEMKO 588W - WHITE (MATCH DOOR FRAME) 0 Cl) TIMELY PRE-FINISHED KNOCKDOWN c0 - GLASSBASE (KD) POCKET DOOR FRAME YIEWPORT DOOR STRIKE: SCHLAGE 10-025 (OR EQ) TO REMAIN LATGHGUARD • STRIKE: (OUT-SWINGING DOORS ONLY) DATE 05/23/2018 HEAT TREATED CASING RETAINER , •, t BADGE READER PROVIDED BY OTHERS SCALE CLIP FOR FLOOR MATERIAL, AS NOTED DRYWALL SCREW (I)NEXT TO SEE FINISH PLAN/ PANIC EXIT DEVICE: VON DUPRIN 3000 SERIES EXIT DEVICE W/ CONCEALED VERTICAL MGR HI-IL CLIP JAMB RODS W/PULLS, SATIN CHROME. LEGEND SILL �, BIFOLD DOOR TRACK: GRANT OR EQ. JOB CENO14 F SINGLE STAIRWELL DOOR - SG WOOD DOOR METAL DOOR FRAME (SIM) �14 T FRAMEPOCKET DOOR JAMBW/ CHEWY VENEER W/ CUSTOM MEDIUM METAL SIDELIGHT COAT HOOK: 3M "COMMAND" •b85621 FOREVER CLASSIC BRUSHED NICKEL SHEET CHERRY STAIN WI 60 MIN. TEMP. FJZ GLASS LARGE METAL HOOK MOUNT a +48" AFF- VIEWPORT IN TIMELY STANDARD PROFILE CillBROU.NTONE PAINTED FRAME. PAINT FRAMES 0 1 " 2" 4" c-PULL TRIMCO 1111-IA.200 SCALE: 6" = 1 '-0" D-DR,PCKT PT-4 ON TENANT-SIDE. SCALE. 6 - 1 '-0" D-DRAIL SCALE: 6 = 1 '-0' D-WNSL-mtl2 ASTRAGAL: F'EMKO 355DV(ON CORRIDOR SIDE USE DARK BRONZE ANODIZED) OF SHEETS HDL DESIGN HEREBY)EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NIOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION ANO CONSENT. I 1 REVISIONS BY DEMOLITION CEILING PLAN NOTES: LALL LEGEND SYMBOLS LEGEND 05/23/18 0 ALL IMPROVEMENTS ARE EXISTING TO REMAIN, U.ON. WALLS TO BE REMOVED BIDSET/ PC EXISTING 2x4 SUSPENDED ACOUSTICAL CEILING TO EXISTING WALLS TO REMAIN REMAIN. 2. EXISTING SUSPENDED CEILING, GRID AND HVAC DIFFUSERS, SPRINKLER HEADS TO REMAIN, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. EXISTING 2x2 UPGRADED SUSPENDED ACOUSTICAL SEE MECHANICAL AND ELECTRICAL PLANS. CEILING TO REMAIN. 3. DASHED ITEMS INDICATE (E) WALLS, CEILING TILES/GRID, LIGHT EXISTING 2x4 SUSPENDED CEILING GRID AND TELES TO BE FIXTURES ETC. TO BE REMOVED. VERIFY PER ELECTRICAL DRAWINGS. t t REMOVED FOR NEW WALL CONSTRUCTION (TI-IRU-GRID). H' -- SEE FLOOR PLAN. SALVAGE ALL TILES (COORDINATE 4. REMOVE CEILING GRID 4 TELES FOR REPLACEMENT WHERE WALLS ARE WITH LANDLORD) FOR FUTURE RE-USE. REMOVED AND WHERE NEW WALLS ARE TO BE BUILT. SEE FLOOR PLAN AND RCP FOR NEW LAYOUT (SHADED AREA). SALVAGE ALL TILES FOR D D ■ r E EXISTING 2x2 4 2x4 LAY-IN LIGHT FIXTURE RE-USE PER RCP. 6 o L,,,,,; 0 5. (E) LIGHTED EXIT SIGN TO REMAIN AS-IS. SEE ELECTRICAL ¢ EXISTING FLUORESCENT SCONCE TO REMAIN (ELEVATOR �� ; 6 ^ 1 6. (E) HVAC SUPPLY AND RETURN REGISTERS TO REMAIN AS-IS UNLESS LOBBY) ^l ' '4' M 1 MODIFICATIONS ARE REQ'D- SEE MECH. DIIL. �Y °`'� O EXISTING FLUORESCENT BOWL PENDANT FIXTURE TO °C n N. o T. EXISTING CEILING HEIGHT TO REMAIN AS 15 THROUGHOUT (+/- e'-I/2") REMAIN (ELEVATOR LOBBY) �j c r S. RELOCATE LIGHT SWITCHES AS REQUIRED FOR NEW LAYOUT. SEE ° EXISTING RECESSED CAN LIGHT FIXTURE TO REMAIN W > x 0 ELECTRICAL PLANS. (RESTROOM VESTIBULE) U 0 ,_ `` lel® LIGHTED OR LUMINOUS EXIT SIGN (ARROWS INDICATE EXIT Q_ o 3. REMOVE x SALVAGE ILLUMINATED EXIT SIGNS FOR REINSTALLATION AS DIRECTION). ■ r 6F, NEEDED. SEE NEW REFLECTED CEILING PLAN 4 ELECTRICAL. lm. REMOVE TRACK LIGHTING 4 REPLACE CEILING TILES PER RCP. FIRE SPRINKLER HEAD (E) - SEE FIRE SPRINKLER PLANS 77, '4190 SUPPLY AIR DIFFUSER (E) - SEE HVAC PLANS 11. REMOVE 4 SALVAGE 5' RECESSED PROJECTION SCREEN 4 SWITCH .% 'EMI-1ER H. LARSEN (BEST ONE) FOR RELOCATION TO NEW TRAINING ROOM. A " RETURN AIR GRILLE (E) - SEE HVAC PLANS 12_ REMOVE GYP. D. SOFFIT 4 RELATED FRAMING, LIGHTING 4 FIRE $ LIGHT SWITCH (E) ROSENIU.E, CAUEORNIA2 SPRINKLERS. SEE RCP FOR REPLACEMENT. cAPA ARI-11468 O OO SMOKE DETECTOR (E) .9J, EXP.12 31 18 13. (E) WALL TO BE REMOVED. SAVE (E) FRAMING/ GYP. BD. TO RECEIVE S F OF O" (E) SUSPENDED CEILING 6 NEW SOFFIT 6 +e'-0" (FIELD VERIFY). RE-FRAME AS REQUIRED TO SUPPORT SOFFIT TO REMAIN. w r•, D LIMIT OF WORK (SUITE 500 EXPANSION) y EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 (HATCHED AREA) Z 0 _ C1) 0 0 o E) _4� . -ter`, CD CD CD o z v O ol W ,"� J 2-tr.. .', 41 + is / / U3 r ...LI _ _J� / _i" • r tar Z 1 .§. / •r: i la 0 0 71 r-- it,11 4 1 i , 1 ...,- .. .,„. =...' ' / .'. ..- .....--t.!...- , , . ; . i. ...:..: .r->_.: ::::.:::::::.:.::#....... -,...::. . .....: ::.. -.. .-.. .T._ �.: - rte.' r _ ____4 7 .. ..' ' 1=t. :tti . -' 0 I'.II 'tW1 .._ :: 1 :A ,,,,,0:,, F 7 ' ^I w:: 1 F w Y— /' - . TII •5 _ : • 7 i m a 1-- • : • ` : . ....v.. ......: > V! III � `•, 1: i , 0 p 1 ✓ F • It:a, gg::: ' •' F k IIITH . , Yv I ! Y CI 1 rn ✓� n- I I V � I II � �_ .� � __ _.:v� ..__ __: ._... __�J ��- ._:;� ....41.1 E' ��. .:_...� ' 0 a aPI �� - { u I L�1 - tYP. _ n O_,...._...._ ....,:i. ,...... ___ _1 _ _ 4 — -.• ._ 1 : 0 g ' 1 1 -..„ I n - ,I fi 1 I :MIL, ;� II I �- I I s �„ r I P �' 1` I. 1 ::: -- - , 1 1. n �:. i ^ I I ! .r .._..1 T- I � I.L. � � �e I :� G �a :r X II f I 1 I -� ISIo is I� I;' � .� • I is I . -4-/:�f � .. ...-. 4�-�..--4..- IL ---. _ �.>:- H l • I CD i I _ � •i 7 : �1 I fi II iI I Ill' :� %` � � I :',.. � i;r `I I I I n• f •i� , I = T,. • f '1 t err , I s ! 1 i , : : _ _ 1 al -�+ I� , d / , , , , 1 i; 1 ��VJ _r- Iii ••••N.,... 11 lFi! i 1 f - i0', - •7ILL v . : , _ I f $� { 7 l> 4, W.atlt,.... r' • I � F 4..' I � 3 i' � 0. I � o � 1 d�- Z O f a n I - I l � � x 1 Y }IIII I 1 3r,,,. I I� � � : } I i ❑ : iii_ :r l 11 1'1'r: 1 d+ I I - ., ... , . „ , .f? : I � � I ! rr , I r z a : ;,r : . 1„ . .. 1 ; ; a I I l' �I � � 1 _,,,� LLLH ± �' _.__ ---- ...."s ' .' '. ill: '7: '--r---7./ T/L / .. >-- a - --:!.:— 7. 'it —:'."'-'" -r--,1. _71. 7---4-: -i.-,.-2,1i-- -L- --1,. --Ifi-- i' zL____M-- , II 1 1 I ''.4'''''''', 7 -1-Tin--4._-_„._ ____: • 'IliT....„_..,>,; _ ••' 1111:441Hil i.ii".,-4i.i rii.:.:i iiz'' '.:,:,: I 1 1 ,.1`-• >: : :r i i . 7 . 0 - 1 i-- '1 4---I - I ---' ----g-"'t.-/ .---''-=1 LI- 1 d• „, Nr 4 �,r y 1 /' cw : :i : ' ,',./. /,s i_.,L,/ s-ailT7i---/- // . ''''' ,./ // s . . ' cn CD 1° --'-5 , Mir • 1 _III o .I .r :` I'II I�t((/(.r°6� _ I • i. C.i- ,fi ....v.,.,.. ..:.,..,..,.... . ' ' 7/77:> ! g 3 _ _- _ _ • i d r H _ T _ c1._I1 • c. • :'-r •\ 1 / I 1 • % I' • I • I I I N NV-,--,-,g� r 1 I: I € 101,,:,:1,-, ,1 1 __ 1 L . L i, 1_ I fi` I II : e ».;. , I Ti , : I R 3 — — '-j 0 -- - -O - £'J - } - - - I I 1 1 I 5 s E • �i O • I I I I ` r Ir 7c } • __ - --I-- ._a- -L 'a'm `'"�p�( I _ T. I .....E ,' n n i o f 1 - 1 1 `• r { : r - - 1. 1 _ � O - _�_ 13:r ---1- I-- -�-1 � ,-€ � �-• � �--- ^ rte- � ,:- /,• r' / �. "1 1 I — �r '- j I Amik• °".,... ! t F q i1 7 - I I , ab T I I / it- , ` i I — ---Hr <; O I ! n• _ a I 1 I I I v' •- ' 12 10 /`' �F- 1 1 %. O� }r. „ ' :� 1 % z LU o o I o_J : : ' ' i % W/ • r.% ti i ! � I • CC' 7 r %. 1 ' / r • _ y d+ /` f rr f /J ' • 4 1 0 - I r .11;1 d I 1 1, ____ _.„,.,..:._ •.. ,- .L. 49--., ,,, , ,- ._ ... . . .... ,L.-. ._ „, i0 • - .. .. , 1- a _ _ ..._ , : r I tif . ' I � il pz TYPICAL NOTES - W W 000000tsi - --- ::,::..1 • ..:....„. j R11 0 ... „ r „:...:_.. ...:m "_, , _1 0 4,( ,, ,,, _______--* • .. „„,„:.„.... :.. .4.0, DATE 05/23/2018 O 0 Ci) (1) — ...I O 0 ® 0 • SCALE AS NOTED '' EXISTING SUITE 500 TO REMAIN - HATCHED AREA, U-ON. .o'. MGR HHL LIMIT OF WORK (SUITE 500) EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 - HATCHED AREA, U.O.N. JOB — ,' ,' CEN014 SHEET 0 DEMOLITION REFLECTED CEILING PLAN A-300 SCALE : 1/8” 1'-0” Z k OF SHEETS 1 HDL DESIGN HEREBYI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE riDT TC BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. i REVISIONS BY REFLECTED CEILING PLAN NOTES; SYMBOLS LEGEND SYMBOLS LEGEND CONT.... DETAILS SYMBOLS LEGEND 05/23/18 OI. ALL IMPROVEMENTS ARE EXISTING TO REMAIN U.ON. 14. ALL CEILING TILES SHALL MATCH WITHIN A ROOM. REPLACE DAMAGED OR NEW 2x4 SUSPENDED ACOUSTICAL CEILING ASSEMBLY TO QBE® LIGHTED OR LUMINOUS EXIT SIGN (ARROWS INDICATE EXIT DIRECTION). BiDSET/ PC MISMATCHED CEILING TILES AS REQUIRED. MATCH EXISTING. SEE A-800 FOR SUSPENSION_ (15/16 WHITE NEW, U.ON. El EXISTING COLUMNS 4 EXTERIOR WALLS TO 2. EXISTING 2'x4" SUSPENDED T-BAR CEILING GRID, TILES AND HVAC DIFFUSERS, T GRID BY ARMSTRONG OR EQ. W/ 2x4 "SECOND LOOK" TYPE REMAIN SPRINKLER HEADS, ETC. TO REMAIN, UNLESS OTHERWISE NOTED OR REQUIRED 15. REMOVE CROSS-TEES WHERE REQUIRED TO ACCOMMODATE NEW LIGHT TEGULAR TILES) V.I.F. RE-USE CEILING TILES AS AVAILABLE • FIRE SPRINKLER HEAD (E) - SEE FIRE SPRINKLER PLANS EXISTING WALLS TO REMAIN BY CODE. CLEAN ALL AIR DIFFUSER GRILLES AND REGISTERS. PATCH AND FIXTURES ORIENTATION. (TED) SEE ELECTRICAL FROM DEMOLITION. REPAIR WHERE WALLS REMOVED. - SEE SHADED AREA. -� C\ SUPPLY AIR DIFFUSER (E) - SEE HVAC PLANS 12/A-100 ,- EXISTING FULL HEIGHT WALL. SEE PONY WALL 16. PAINT GYP. D. CEILING 9 LOBBY 4 RESTROOM VESTIBULE PT-3. 14/A-100 NEW 2x2 SUSPENDED ACOUSTICAL CEILING ASSEMBLY TO DETAIL IF NOT FULL HEIGHT. 3. SEE ELECTRICAL AND MECHANICAL PLANS FOR LIGHTS AND HVAC ' : MATCH EXISTING. SEE A-500 FOR SUSPENSION. RE-USE RETURN AIR GRILLE (E) - SEE HVAC PLANS DIFFUSERS/DUCT DISTRIBUTION. I1• RELOCATED S' RECESSED ELECTRIFIED PROJECTOR SCREEN. CENTER IN ROOM. -1... CEILING TILES AS AVAILABLE FROM DEMOLITION. 13/A-100 NEW CEILING HIGH WALL PROVIDE RELOCATED SWITCHING. SEE DETAIL II, A-100. $ LIGHT SWITCH (E) 4. NEW CEILING GRID TO MATCH 4 ALIGN WITH EXISTING ADJACENT GRID, TYP. EXISTING 2x4 SUSPENDED ACOUSTICAL CEILING 12/A-100 NEW FULL HEIGHT WALL IS. NEW RESOLUTE "PUNCHEON" PENDANT LIGHT FIXTURE (5.5" DIA. x 9"H). INSTALL CEILING TO REMAIN. o SMOKE DETECTOR (E) C ■ n E 5. PROVIDE NEW HEADER/ SOFFIT WALL TO ALIGN WITH EXISTING FOR ACOUSTICAL B.O. FIXTURE 32" ABOVE COUNTER IN BREAK 4 TRAINING ROOMS. s i ° COCEILING TRANSITION. SEE DETAIL 6/A-100 EXISTING 2x2 UPGRADED SUSPENDED ACOUSTICAL .8 ci 19. RELOCATED AIR DIFFUSER TO KEEP PROJECTION SCREEN FROM FLUTTERING, CEILING TO REMAIN_ (MATCH EXISTING) L= g 2 m 6. PROVIDE NEW CEILING TILES TO MATCH EXISTING AS REQUIRED FOR FOR NEW AND TO PROVIDE CLEARANCE ABOVE CEILING. (I) E1 v L o 6j WWALL LAYOUT, (AREAS SHOWN SHADED) n• EXISTING 2x2 4 2x4 LAY-IN LIGHT FIXTURE - • n Pr: I e, n n . 1. PROVIDE EMERGENCY BATTERY BACK-UP IN CEILING LIGHT FIXTURES, PER EXISTING FLUORESCENT SCONCE TO REMAIN n v n o _E CODE. SEE ELECT. PLANS. (ELEVATOR LOBBY) u 1 vv o 8. (E) JANITORS CLOSET, RESTROOMS, ELEVATOR LOBBY 4 STAIR CEILINGS/ C EXISTING FLUORESCENT BOWL PENDANT FIXTURE TO L 5 = o LIGHTING 4 EXIT SIGNS TO REMAIN, UON. REMAIN (ELEVATOR LOBBY) a U C7 a `` o_ o 9. PROVIDE NEW WALL ANGLES WHERE CEILING REMOVED AT NEW FULL HEIGHT o EXISTING RECESSED CAN LIGHT FIXTURE TO REMAIN Z j WALLS. SEE A-800 (RESTROOM VESTIBULE) _c 10. UPGRADED CEILING ASSEMBLY AND TILES AT TRAINING ROOM V.I.F. D5 NEW 2'x2' 4 2'x4' METALUX 02 4AC-LD4-55-UNV-L535-CPI-U NEW LIGHTED EXIT SIGN. SEE ELECTRICAL. ���,q9c 11. LED LAY-IN LIGHT FIXTURE (OR MATCH EXISTING) gtlEATH.' H. LAR,1 T, • NEW RESOLUTE "PUNCHEON" SMALL DECORATIVE 12. RE-USE AVAILABLE ILLUMINATED EXIT SIGNS. SEE ELECTRICAL. PENDANT LIGHT FIXTURE (5.5" DIA. x 9"H) - :-> ROSPALLE, CALIFORNIA 13. SEE SHEET A-800 FOR CEILING SEISMIC 4 SUSPENSION DETAILS. _, cpx ARI-11468 O EXP.12-31-1 B '..if),. TF OF 6" w c" z LIMIT OF WORK (SUITE 500 EXPANSION) EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 (HATCI-•IED AREA) o 0 Z 8 / / CD 2 CD (_-__)) 0 t a • ,,_ 6 0 — CO9'-01/2AFF. (TYP-) CEILING EI 9:..+. 'III QF ni , r :° 'III` IVI, r. • L_ .n. Imaij cli • 8 • 7 \ - ...., ,..., ...:: :::: . . . . . .. ., „ .. .• ir--4 7 - Fri I :-ri- , . wQ aTYP. HEIGT — r l + U0 .. I n r f r ` nG � i , la r` q , -� t I . r f ' - 0 r _. :..,..,. .,..,..,..,...,..,..:..:...:..:. _i_ ______:Fil • r'}I � Oc D ,, r Ir _ _____.. ___, , .. . „ L : 1 o ;. . n l ,..„ .., ........ c„---)„ ____EL..._ _____ . .,;!' . , ..: • • ,....... .. .. .. f• . L. • -p • , El_____, 0 ro0 r iwirl ! : -4- (Si) 1\ • OL- _,® • 1 • /-• . e1 • i e s 7 ,./. • I ,,--,7-7,„-, _._-. ate. " � a • n • 1 O Ain. os ♦i 1 I r c ri . 1 H I — 1 rr: 3 • i :, r � 1 } I CO �..•� / , L 1 ,_.,. r r r r ; .:::: °�� 1 _____LJ D ..., ., 0 i , : I: N o • n 1 r? � _ • :;.;\)'' J r'J i li; r .r- r,. : , , . . • r-iv. f \ o: Z � f f (:3 �•y•- S �1. Y:� W. o o :o. �`r ..-// . r : r i .nv. Foil) : 1 • / .... CJ f : : • •: i 11iL:, - / XIII a .. . „. ' ±L.,6....,_. ........ , e` Il Z , : -'-' i O -7--- L .. 7 IF . . . . V j..,) 2M J} : 2L , cri • 0-3s. [, :r . .:-......::::--. ...::.:,..... .. \ r=1 : w CD Ik :....• ' - ___-11- s I I 5 A - '^ 1<' • - • to \ {;i r f Cr) _ i r s �' csi % - - .... ,r .,- _ l 1 I• -.... ..d..... - -- • ® ��--•------ ,.6 ,•+damo j x ' _ T Cr'. --Li- i . / ' 1+1 :L.n' 1i . I if L C NCx;� ..3 i l F 1. ...rAir r f r 115. - L ' zTi 18 ......J c1 i r� y' • • • b V I 1._,, • O In 1 lir :, [741;1 -la- -a., ,.. _. _ , .H --SD— n 0 -.ham, "42L- S = I r E fr. 0 O it ' l•`r I I • I • TYP. �---- =�r o / ) ► d •r {] 1 :-!." :-! •:..:!.::.:-..i:L !':•:':!.:-.1'1!:'.;.:11 .....- '.... ........., ,... i �, �. .�.� - �. ' • . fir• sin 1 .. .:Ii.../ .., Z ; 3 � ______4---- • m ...„ r`" g 6._ ill .. .. . .. i .. :.: , .. . r r rJ' 4- 0 : : i � : ; •ice ; Li , • . . . 1 CI • C) .....--.. . ._.., ' I 1 I+ f • • I' o I i L. /1 err , w r r ; r :' 1$ I, I' U , i r r r , 1 • � n- r ..L r wo c I r I - � I I 1 r " I �- - ._, .. .. ii '' I .... ._-,1--. ____._., �Y 3 .. W SOFFITS [ 6. "., ^ - \ , I T � a TYPICAL NOTES ''" 1 .. .. ° ' •I • ,i� ' TYPICAL NOTES W 0_ 00000 ......... .. .. 1 DATE ,,,,,,,,,:,,, • • E / . • Z. l• • s 00000 0+0+Cte. 1 , s ,: 4ti CD 05/23/2018 CD. O 0 0 O �„1 _- „•0+0+01 I 0+0 : , • i...rivi'l - �� 00 0 SCALE AS NOTED EXISTING SUITE 500 TO REMAIN - HATCHED AREA, U.ON. 0 J, / 0 MGR HHL 1 - LIMIT OF WORK (SUITE 500) EXISTING SUITE 520 TO BECOME A PART OF SUITE 500 - HATCHED AREA, U.ON. JOB CEN014 / SHEET 0 SCALE : 1/8" • 1'-0" z NEW REFLECTED CEILING PLAN A301 ___________ I 1 1■.■ , I OF SHEETS 1 HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE Nix TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIiSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. i REVISIONS BY FINISH FLAN SHEET NOTES DETAILS SYMBOLS LEGEND FINISH FLAN GENERAL NOTES 05/23/18 CD SEE A-600 FOR NEW CASEWORK, WALL ELEVATIONS AND FOR 15. REMOVE GREY FABRIC WAL I-COVER ING IN ELEVATOR LOBBY. EXISTING WALLS TO REMAIN I. CONTRACTOR SHALL PREPARE ALL FLOORS AS REQUIRED FOR PROPER DIDSET/ PC ADDITIONAL FINISHES. PREP 4 PRIME FOR PAINT (PT-1). PROTECT (E) WOOD WAINSCOT. INSTALLATION OF FLOORING MATERIALS. PAINT CEILING PT-3. r 1 EXISTING FULL HEIGHT WALL. SEE PONY WALL 2. ALL GYP. W. WALLS 4 CEILINGS SHALL SMOOTH FINISH LEVEL 4, DETAIL 14/A-100 IF NOT FULL HEIGHT. 2. ALL AREAS TO BE PAINTED SHALL RECEIVE A MINIMUM CF TWO (2) COAT U.ON. 16. PROVIDE FULL HEIGHT CORNER GUARDS Q WALL COVERING (WC-H.1). 12/A-100 •. NEW CEILING HIGH WALL LVT-3 (1) ROW - DARK GRAY APPLICATION THICKNESS, AS RECO MENDED BY PAINT MANUFACTURER TO OBTAIN TRUE, EVEN COLOR OVER PVA PRIMER 3. SEE 1/A-100 FOR FLOOR TRANSITION REQUIREMENTS. 11. EXISTING COMMON AREA FINISHES TO REMAIN AS-IS, (TOILETS, 13/A-100 NEW FULL HEIGHT WALL STAIRS, ETC) U.ON. -LVT 2 (2) ROWS MEDIUM GRAY 3. INSTALL RIBBER TRANSITION STRIP WHERE CARPET ABUTS VCT OR SHEET 4. PRIOR TO FLOORING INSTALLATION, CONTRACTOR SHALL PERFORM X-1 FINISH TAG _ , \sr VINYL, TYPICAL. STRIP TO MATCH RUBBER BASE. MOISTURE 4 PH TEST ON CONCRETE SLAB FLOOR TO RECEIVE 18. REPLACE I" ALUM. MINI-BLINDS AT EXTERIOR WINDOWS WHERE �� .� ( LVT-I (3) ROWS -LIGHT GRAY CARPET TILES AND RESILIENT FLOOR CONTRACTOR SHALL WALLS ARE ADDED. MATCH (E) LIGHT BRONZE METALLIC COLOR, k , -, i , 4_ INSTALL ALL MATERIALS PER MANUFACTURERS' PUBLISHED INSTRUCTIONS_ VAPOR SEAL CONCRETE FLOOR IF RECOMMENDED PER TESTING. V.IF. =`� , ` C ■ E o . 5. THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT MIN. (2) 8 1/2 X 11 O „^, ° 5. EXTEND FLOOR TILE 4 BASE INTO WHEELCHAIR SPACE UNDER SINK 19. RES IL[ENT LVT-2 FLOOR TILE ORIENTATION IN MOTHER'S ROOM. �� `� \' BRUSHOUTS OF PAINT COLORS AND SAMPLES OF ALL FINISHES CrtCIFIED ._ °` g (ASHLAR INSTALLATION) �� FOR REVIEW PRIOR TO PROCEEDING WITH INSTALLATION AND/OR o� 6 2 6. CARPET TILE ORIENTATION PER LAYOUT. TYP. � ?. APPLICATION, IF REQUIRED BY OWNER V) ... V o 0. PROVIDE BASE UNDER SIDELIGHT WINDOW FRAMES, TYP. SEE , Ni,�� e� 21 PEAK ROOM 4 W - 'i ^ n `9- 2 1. NO INTERIOR WINDOW FILM OR MINI-BLINDS ARE REQUIRED. FRAME ELEVATIONS SHEET A-200. :N MULTI-PULSE 6. PRIME AND PAINT ALL ACCESS PLATES, PANEL BOXES, ETC. TO MATCH �. . :;� ROM ADJACENT SURFACE, UNLESS OTR-HEi�.JISE NOTED. SUBMIT SAMPLE TO Q .; s 8. (E) MDF CHAIR RAILS 4 WINDOW SILLS TO REMAIN. PAINT TO MATCH 21. RESILIENT LYT FLOOR TILE ORIENTATION IN BREAK 4 i ARr"HITECT FOR APPROVAL IF CUSTOM COLOR IS DESIRED. .~ v c-, ADJACENT WALLS. MULTI-PURPOSE ROOM. SEE LVT PLANK PATTERN DETAIL 2, THIS , -. , '"'" ° SHEET. `` `\ 1. EXISTING CONSTRUCTION TO kEMAIN SHALL BE PROTECTED FROM ` 5 z a o 9. TRANSITION BETWEEN CARPET COLORS. �. ` C7 a `` (Sj ;�, 't DAMAGE AND DUST. a 2 0 22. REMOVE 4 CHERRY WOOD BASE FROM PREVIOUS CORRIDOR U. 10. USE CG-I AT ALL CORNER GUARD LOCATIONS SHOWN IIU.ON. REPLACE W/ RB-i. :� - ;� S. ALL EXPOSED FIXTURES AT SUSPENDED CEILING TO SE WHITE , INCLUDING Z Q In .- --moo -- ` -- ` -- ` -- -- , A -- HVAC GRILLES, TRIM AND ACCESSORIES, UNLESS OTHERWISE NOTED OR TO s 11. TAPE, PRIME, AND PAINT INFILL AND PROVIDE MATCHING BASE. 23. PAINT TENANT SIDE OF (E) DOOR FRAMES PT-4_ MATCH BUILDING STANDARDS. 12. EXISTING FLOOR FINISHES TO REMAIN IN HATCHED AREA, UON. 0 LVT PLANK PATTERN Z `3 ALL FINISHES SHALL CONFORM TO THE 2012 ISC/2014 OSSC. tlEATHER � 44.0 H. LARSEN it 13. SEE A-500 FOR FINISH LEGEND. 10. ALL WALL FINISH MATERIALS SHALL BE MIN. CLASS 'G', FLAME SPREAD SCALE : 1/8" = 1 '-0" INDEX 16-200, SMOKE DEVELOPED INDEX 0-450, PER 2012 IBC. • # ..'• 14. WHERE WALL COVERING IS REMOVED, PREP. 4 PRIME FOR PAINT. ROSEVIULE, CAUFORNIA2 II. PAINT TENANT-SIDE OF COMMON AREA DOOR FRAMES WITH PT-4. _, CP, ARI-11468 O 1 EXP.12-3118 TF OF 61/4 W U' Z z > O :_ J m W , W 0......i � Z0 CIS 0 ‘ •in . • e ee u Y u u u O , - .... :� :.:.:.:.. .fid.,: .:.�`� ::�, `„ � :='`�� Z � � I W 1 Lia . 11 .'� U 1 HOTEL �' I . • �f'�IQd . ØITP. T OFFICE 14 7 FT-2 P7-12 ` 2 CPT-2 - 0 OFFICE 4 0 ni m ' : . .. COIF 1 .` ::: .......ry...... PLANK :•' r -. } a � T-2 .-/- ../ ` - : • . . . - - 1 , . . . .. -- '. ...- ....' dp....-=k dui. •- P OFF' 13 � f J I': F I DR ter'' / f PT-2 _: ,.,,,. -- 0 .• CPT-2 :' : .• ../ ; �• :� �=T-12 CPT-2 , CES Z t ØTYP O : 0 ' , 1 fi; GPT (N) GOER DORS 1 -I s 22 TYP. • fi I O1,ICE 12 . .. 0 -1 LT STOFt/ r +3 DLE 2 HUDDLE 3 PT 2 1 JDDLE 1 }41D - , ' W GPT I 1 .... P «, 1 - - CPT-2r :. RIDDLE 1 HU I / § 'CPT 2 GPT 2 DOLE 2 7 i f :r r COD CO f "i I - , T 2 • ....� P , rb,, $ :...... .h...:::::::::::::.:. .... I I • ` PT a. i r `1;' - ,r+: ELECT,. - - ,t.t : : 1 '`I 4VVi�9 4'G� h 0 I I1) . T ILV 8 0 • : : : .f, EQUIP ,., a/ ) v�4TORS � I� • - LE it o o s :orIc; r T � 7 PT-5 T � �' STAIR t ` 15 fi-` W o Fr I f } o C � > '�iI o - - _CPT-1 :` �' f Q limb..'f ` o• .y F y a ØTYF - - . - . - _ I MOTHERS 1� 0 ,. 5 =�i� IL u$.: ® I PT-10 LII of . Z g _i 0 IZ J4111 Y PLANK fiA". _, PL I� PT-2 �p •TYP. eII Q DIR �O YT 1 \ MS r : , 0 r (\,,,)„_ n�� i•! L [C' _ T 2 LYT-2i' WALL0321_ o LVT-3 0 fi fre� /r O O • ,� �_ TI E N : -----y--\ n Al • 1 •TYP E J j i � G f •y ,: ST .�: C -i , PT f . °° r OFF' , PLANK % _ : �:.. OPEN OFF' 2 , > > ID f I2 ØTYP. 0 ,fs o r /f 1 OBE4( - 0 LVT1 � / fi LVT-2 . - LVT-3 ``.. �.: rt. i`` r` .T, Li 0 . ,Qiir .. m ; r ' , ..7Q-- . --\if - _--- ..-. -- - / I ,,- .-.- ... /- //.. TRrs PT 2 OFFICE 11 f CPT-2 OFFICEB OFFICE �' PT 12?E) i' T' (W PT 5 CEJ PT-2 ,1� OI�FI g. I I CPT-2 0 . { f : : 0 - J LC-1I0 11' ' 45 •PZ Ofi . { fi: „ / /iff i -N-, J o CL TYPICAL NOTES: :' (}r� . `: TYPICALNOTES: / (E) 00000 �- oo �-0200000140 _ I _ J Z • Y ' '' // TYP. FINISHES THROUGHOUT U.D.N. � �� � ?,� �3 - -. TYP. FINISHES THROUGHOUT U.O.N. IRS-11CFT-1IFT-ISACT-1I(E) ` � ° IRB-RCPT-IIPT-I AGt-11(E) - f 14- DATE 05/23/2018 SCALE AS NOTED MGR HHL JOB CEN014 SHEET 0 FINISH PLANA.400 SCALE 1/8" = 1'-0" Z OF SHEETS I 1 1 1 HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE N}7T TO BE REPRODUCED. CHANGED 0R COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMI4SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. � r ... .... .Luu.. l .... .. ...... ..... ..:.:::........................ 1 /Ii...1.....c ... I [LLL............I i.m.luuuu ..i:.. .......cc.............. . i I REVISIONS Y RESTROOM NOTES ::::::: f _ ENLARGED R E : . ::. ::.:... . .. . ....— ::.: ..... ......�. ...................... :.:.> :.. .�... .................... ... .... 05/23/1 e KE 1=iNISN MATERIA(. SUPPLIER CONTACTS A N RLIENE (314) 365-225 RB�1 RJDBER BASE MANUF. 4 VINYL 123 CI-ARCOAL STANDARD Aft B4 E USE STRAIGHT &E LW C/ T, COVE E ASE U'ALL errLE BIDSET/ PC O EXISTING: REStROOMS TO REMAIN AS-IS, U.ON. OTtERFL0oR5u�A! Suox INTERFACE: v -� CTS-I TILE SASE DAL-TILE "FA19RIOUE" USE CT-4(€2x24 AND CUT TO 6x14 CREME LINEN P666 RE6TROOM WALL BASE - USE WITH ST-I'IN5T4L L 1 /SC4.LUTER GAS I: DENNIS UPSNAW (314) 381-3191 KOROSEAL: ‘ ///all... 2. 5' DIA. TURNING CIRCLE. _ SONDRA CARL SON (515) 321-1282 •:: CA '1 - 3. EXISTING HIGH 4 LOW DRINKING FOUNTAINS. ARMSTRONG: KEY MATERIAL MANUF. STYLE COLOR REMARKS L J u BRENT TESREAU (314) '109-0185 GOLTERMAN 4 SABO (DESIGN TEX): CARPET TILE, SILVER LININGS, SL' 2a GENE OFFICE, 4. INSTALL NEW CARD READER MOTHER'S ROOM. CPT-1 INERTFAGE 104513 GRAPHITE LINE GYNDI WALKER (636) 225-8800 PLANK (9 ads"X3938")_ 20 r (INSTALL PER PLAN) GI SELECT (ENCORE, TNEMEC. ROPPI, CARPET TILE, SILVER LININGS, SI-S30 PRIVATE OFFICES/CONFERENCE ROOMS/MISC. • JOI-1NSONITE): COMPI DISTRII.UTORS (WILSONART CPT-2 PLANK INERTFAGE f9�g"X3 &") 104525 GRAPHITE FADE (INSTALL PER PLAN) ELLEN ZUCKER (314) 4S6-0591 P-LAM): ... I > 'TELE` { " ' ;;. .. L� PATRICK ANGEVIN (314) 809-5114 'i INERTAGE' ( ;�K ) 1'D4944 IRON NON-DIRECTIONAL �! F I-- ) (:::::: A T1 11 NCo T<• LtOR'.NG JOANNA ANDERSON (314) 629-0215 AMERHART (FORMICA): "" """"" '""' ' SCOTT FARRIS (309) 635-2 50 KEY MATERIAL MANUF. STYLE COLOR REMARKS coV• .� °` 5 �� ISG SURFACES (AMERICAN OLEAN): LVT-I RESILIENT - LVT INTERFACE *4001 "STUDIO SET" (9.845"x3938"1 400101 SILVERLIGHT STANDARD RESILIENT FLOORING:(BREAK ROOMS 4 COFEE BARS) N u� 2 6 KEVIN PARDO NATIONAL OFFICE FURNITURE: • (LIGHT GREY) ��i Ti' JILL JONES SURFACE MATERIALS LVT-2 RESILIENT - LVT INTERFACE *A001 "STUDIO SET" (9545"x3938") A00102 PEWTER STANDARD RESILIENT FLOORING(BREAK ROOMS,COFFEE BARS,4 MOTHER'S ROOM) °� S © III MAPEI: MANAGER (MEDIUM GRAY) ,. ,. o BOB DIENSTBACN (314) 484-5300 OFFICE FOR PERMISSION TO BL11' LVT-3 RESILIENT LVT INTERFACE *4001 "STUDIO SET" (9$45"x3938") 400103 PEPPER STANDARD RESILIENT FLOORNG(BREAK ROOMS 4 COFFEE BARS) L V rn rn E I I -1 I I SHE RWIN-WILL IANS: (812) 634-3006 (PARK GRAY) U & o HANK MEINKING (314) 281-1485 iR -s 1R1=5ILIENT- VCT I ARMSTRONG I IMPERIAL TEXTURE STANDARD EXCELON± 1 5ISII CLASSIC WHITE INSTALLER TO PROVIDE 1ST tt)AX APPLICATION I'ERt'Ff,INSTRUCTIONS. -1 0; > — WILSONART SOLID SURFACE: a WOLF GORDON: TERESA NUMPHREY u. 0 0 ;FL, 1rIC L "[1N, Ta — /'�M IC M NS DAVID SMITH (314) 302-8002 (214) 695-8521 KEY MATERIAL MANUF. STYLE COLOR REMARKS mr Q ; 'o �,/I I I�lJ I I J ■ PL-1 PLASTIC LAMINATE WILSONART STANDARD HPL FINISH 4941K-18 COSMIC BASE AND WALL CABINETS, BREAK AND COPY AREAS (LINES TO RUN s OLINEARITY FINISH WITH AEON' I8(PREMIUM FINISH) STRANDZ VERTICAL U.ON.) (1.) 0 0.) PL-2 PLASTIC LAMINATE WILSONART STANDARD HPL FINISH ORGANIC COTTON COUNTERTOPS COPY/ WORK ROOMS, MOTHERS ROOMS, OPEN OFFICE FINE VELVET TEXTURE FINISH •d945-38 AREAS U M LABS dd% _ I 1 KEY MATERIAL MANUF. STYLE COLOR J REMARKS HEATHER H. LARSEN �1 C� DE OF 1................................................ 88-1 SOLID SURFACE WILSONART ACRYLIC BLEND MORNING ICE *9204GE STANDARD SOLID SURFACE C04NTER5, ALL 11ET AREAS EXCEPT MOTHER'S ROOM,LION. •( • ... .............................. .:.:..... � .... ............�.. ... ROSEV! CALIFORNIA .... ,....-. EXP.12-31 18 KEY MATERIAL MANUF. STYLE J COLOR REMARKS 9� 4 ) © / PT-1 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 1551 GREEK VILLA STANDARD WALL 0 F C / PT-2 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 0023 I`'EWTER TANKARD WALLS - PRIVATE OFFICES, CONFERENCE ROOMS, PUBLIC RESTROOMS PT-3 PAINT SHERW{N WILL PANS FLAT SW TI3l HIGH REF ECTIVE U•IITE STANDARD DRYWALL CEILING I I PT-4 PAINT SHERWIN WILL IAMB SEMI-GLOSS FINISH SW 1551 GREEK VILLA RAMP RAILINGS,HANDRAILS AND POSTS,SASE PAINT,DOOR 4 WINDOW FRAME PAINT PT-5 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 6516 DOWN POUR ACCENT PAINT (BLUE) is Z 0 ENL. RESTROOM PLAN Z PT-6 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 6111 PARAKEET ACCENT PAINT (GREEN) PT-10 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 6219 RAIN MOTHER'S ROOM (LIGHT BLUE) Q G= SCALE : 1/4" = I'-0" PT-12 PAINT SHERWIN WILLIAMS LATEX-SHEEN: EGGSHELL SW 6824 FOW_ET -ME NOT ACCENT PAINT (PURPLE) a` J CONFERENCE ROOMS, WALLS OVER SPECIFIED PAINT NOTED ON FINISH PLAN E _, �, 31" U.ON. �, DRY ERASE `: u " i\ - CLEAR GOI-4 *11124209 PT-15 WOLF CORDON WINK (SEEPLAN) 6 -6 = -- UNDERMOUNT SINK NOTES: COATING 4 40OFolic, C13 PROVIDE UNDERMOUNT >: >:; ` COPED SOLID 24" MAX . S.S. SINK. SEE EQUIP. KEY MATERIAL MANUF. STYLE I COLOR REMARKS —I SURFACE .)/ LEGEND. W Q _� 2" TALL SINK RAIL CT-3 CERAMIC WALL TILE DAL- TILE "ELEVARE SEFIVE3" (4'x16u) LUNAR EL4O (W1-�€TE) RESTROOM WET WALLS., BRICK/ASHLAR INSTALL. USE W/GT-2 lil a SCREWED TO CABINET 2. PROVIDE SINGLE LEVERV "ESTRADA" *AGW-511S0 FULL WALL E9.AGIfSPLASI-1 OPTION ON WET WALLS IN BREAK AREAS, ACCENTci,) r CAULK JOINT �` SIDES AS REQUIRED. FAUCET. IC WALL ARC-COM LIME RICKET *2m TYPE 11 VINYL (55/56" WIDE) WALLS#U/APPROVAL 1�" "ESTRAD,4Z" ♦ iU-51198 FULL 41.4 ACKSPL.AS I OPTION ON WET WALLS IN BREAK AREAS, ACCENT ----------- u1C 6 WALLC�OVERING ARC-COM MOODY BLUE "25 SOLID SURFACE- SEE FIN. Trt 1 VINYL11�Z4;" MIDI»1 44 > #f . 11.. 3. PROVIDE BACKING= IN LEGEND. WALL D. FOR WC.--I WALLGOVERING ARC-COM "ESTRADA *AC.IU-$1138 ROYAL PURPLE "18 FULL WALL BACKSPLASH OPTION ON WET WALLS IN BREAK AREAS, ACCENT ,k MOUNTING REQ YP. ALL TYPE III VINYL (55/56" WIDE) WALLS W/ APPROVAL �- (ABI)I TRY. TYPE fI VINYL, CUSTOM GRAPHICS ON NO DRIP EDGE. SEE WG--u WALLCOV'ERING KOROSEAL WALL COVERING, GROUND: SATIN BLUE LOCATIONS PER PROJECT, AS NOTED ON PLANS. DESIGN BY CENTENE • t, DETAIL, THIS SHEET. MAX. (36915"W x 125"H) _.� 34" AFF. TOOFDRIP ,.:::: �:� TOP ,,,...::::::::::::::::::..::::::::: ... .«.. . ...............::::::::::...................... ..- :,�: SINK ........_ .:.. _ � �.::'�`��"'!;>: : , ............. : :te z. ti...:,:,:,: ,:.:xN>:. _ r'' tiri 't KEY MATERIAL MANUF. STYLE COLOR REMARKS I _ VIII 1 CG-1 CORNER GUARD INPRO IPC TAPE ON 1 " FEATHER 0238 VERIFY LOCATIONS, SEE PLAN. I - N :::... .,. .,.,::.,..:::�.:::�.::::�:::::.::::::::::::::::::::.�.:.. .:.:.::: -�:.........:.;...:.,..:�-- ... '� :':. -:-'--.:-.:: ...... :.:.::..444 P-LAM. EXTERIOR ... Z .......--. -..-r.. .... ... ... ... :.............:...,.,r.,,,,r�� .:.:...:.... ...::.:.:.,,,,,..r:rv:C:ti:4.:{.{.,,-{.,,,,.i{. ,-:.,,,xx,�,x,riiii .-- .......................... ... ....:................ ....:r::rrrr r............:.......,,„rr,s:;::iiiii'_` , ii;......-:'�_ ..... ............................................n................................................... ..... ... '��........ ....,:{,.......................-.-.xu,,,:,:.::::::::::.r:v.r.. .....n :.x:::........... , - .........xx,rv.�:.:�.::.:::::...., .\.:x::m•:{?{-iiiiiiiiii}r, CABINET FINISH 0I ... ..... ..... ......::,... _ .......,..ia���o.���. n:�:;�.,.:::...... ,;» ......... ..:. ::... ... .. -.... / P-I TD'LET PARTITION I ACCURATE ! COATED g 314 PART. BD. I(,I,Il:/J:17.11.//IL:...,-::•:::- :,. ..,y{:..w.///LI 11.1.1.'. 111111, \ : . ;;, C2fit r l ILII II111L............................. .0.111111._ I Z CONST GTION (TYp) • ,: _.. >:>; {;{;{;{;.»:;{;:;.:;:.»:.>::.>:::>:::::;:.::.;;:.;:>;>: »>:.» »»:.>:.>:>.<.>:;:;:;::;:::.>:>:::.:-.:-.: - _ MIN- _ I INSTANT WATER la KEY ITEM MUNUF. MODEL FINISH REMARKS W NEATER WHERE EXTERIOR MATCH BUILDING STANDARDS 1" METAL BRONZE MATTE O I WB I N/A INSIDE MOUNT U {� WINDOW BLINDS MINI-BLINDS METALLIC OCCURS we-2 FILM LI UMAR OPAQUE WINDOW FI f"€ t P52,i14•i€TE FROST USE AT BORROW LITER + NETWORK ROOM 4 IT STC)t E1£# REMOVABLE TRAP WB-3 WINDOW FILM LLLMAR STATIC: GR PIANT INSTALL WITH SOLID STARTING AT +18" AFS. m 0 - - -I- - -�\-- , IL. COVER SCREEN, NO uniuuul uuu / Z Z SHARP EDGES WB-4 WINDC7W FILM 3M ULTRA-SECURITY FILM PROVIDE 4 ALL S 1 T FACING STOREFRONT WINDOWS D f(-) C's CO CO X - - j _ r n KEY _ MATERIAL MANUF. STYLE COLOR REMARKS Y w o N �- WI-IEELGHAIR 11111 R', 86 r litACCESS CLEARANCE ACT-1 CEILING TIL ARMSTRONG 2x4 "DUNE SECOND LOOK If" 02112, WHITE DR MATCH BUILDING STANDARDS Z;I''''r • REQUIREMENTCEILING TILE GRIP: 15/16 ANCsLI=D TECsULAR J ac cc) (DASHED LINE) --- -:-: :: : : - R N&TS ►. ... . . 2n6u 3n :.: Ili KEY MATERIAL MANN. STYLE COLOR REMARKS c•' MAX- 1,_�,i ' Q - CABINETS BEYOND t 0cc I ) 1 T-1 TRANSITION STRIP SCHLUTER RENO-U-AEU-100 SATIN ANOD. ALUMINUM TRANSITION I TILE TO CARPET,RESILIENT FLOOR OR CC NCRETE.SEE DETAIL 1/A-100 ):I RUBBER BASE AT T-2 TRANSITION STRIP JOHNSONITE CD-XX-C MATCH RB-I TRANSITION FROM CARPET TO RESILIENT FLOOR. SEE DETAIL 1/A-100 Q F FLOOR SINK LJ =� I Q BACK 4 SIDES. T-3 I TRANSITION STRIP JC7}-WSONiTE ] S XX B I MATCI-4 RB-1 I TRANSITION FROM CART OR RESILIENT FLOOR TO CONCRETE, DETAIL 1/4-100 (WHERE APPL-) - ` 1 OW `, `� 1 E OOR T ` }I_— — — _i rCT-1 F .Al P4GRTILE DAL-TLE j "FABRIQUE" (12"x24"1 j CREME .LINEN P+'SS I RESTROOM FLOORS. BRICK/ASHLAR INSTALL. USE LITH GT-I _I BASE CABINET W/ SINK 48" ACCESS TO FIXTURE Cx�'O�1T - FLEXGDI C7R CO RE4A ''1I' TO E GROUT G 6'' 1 '° tt .ALABASTER �3: I USE WITH CT-1, 014 4 CTEV-1 CO �O III 1 SCALE: 1 -1/2" = 1 '-0" 0 4 8 16 CABASECLR4CO N —V\— PAINTED GYP. BD. ABOVE CONTINUOUS SPLASH 25" OR 31" - IF 31" NOTED, PROVIDE FALSE 31" U.ON. AT ALL SIDES (SEE PLAN) BACK PANEL FOR NEW 22-5/8" (SEI= PLAN) SOLID SURFACE * TOP 4 DEEP CABINET. 25" OR 31" , IF 31" NOTED, PROVIDE FALSE ` SPLASH W/ SQUARE EDGE 10" 45 CIRCULAR WASTE SQUARE EDGE SQUARE EASED EDGE SOL ID SURFALEGEND,SEE FIN. CE- C� CHUTE, THICKENED CONTINUOUS SPLASI4 AT BACK I SIDES BI (SEE PLAN) DEEP CANET. ••••-- COVED SOLID SURFACE SQUARE EDGE l/2" EDGE OF SOLID 1/Z"r' SOLID SUR>=AC(=- 5EE FIN. In"�' SCRIBE TO WALL 31" (U.ON. 25") SURFACE MATERIAL -- AT SPLASH I� LEGEND, SCRIBE TO WALL AT COVED SOLID SURFACE , � SEE ENLARGED PLANS SPLASH (n 1/2"� SOLID SURFACE SEE FIN. LEGEND, SCRIBE TO WALL AT - EQ ID" EQ� FOR LOCATIONS. a COVED SOLID SURFACE NO DRIP EDGE. SEE tr r NO-DRIP EDGE- J I-112" / SEE DETAIL. �t f - NO-DRIP EDGE. SEE DETAIL- Z Q SPLASH LOOSE BACKSPLASN SEE EDGE DETAIL. DETAIL. '1 _ _ ],,,I 118 , , III/2" Q �W/ SIL IGONE SEAL x n � L- = 1/8" W 41. / ! \1-I/2" __ �, �I/S.. - • cc oo II - 22 SOLID SURFACE DRWR SLIpES `4 -i 24" DEEP BASE CABS. C _I MATERIAL PER NOTES PULL O Q WASTE BIN r PULL ( 1/4" PLYWOOD • 1/4" PLYWOOD O w ba- I 1 ( P. LAM. EXTERIOR 3�� y" �( PULL - SEE PROVIDE M . LATCH I z __I11 CABINET FINISH i ' SHELF STANDARDS I IO I SWINGING DOOR D SLg HARDWARE LEGEND '/ (2) ADJUSTABLE Cl) W P-LAM INTERMEDIATE - W Z — 1/4" PLYWOOD W/ SHELVES ' CC SUPPORTS AS REQ'D. I C Q co MELAMINE (WHITE) �� i i/ / s, - SEE ELEV S. I Q �ffffljf/f/f /lffff1.1i �' ��- LU Q 1 1 a I INTERIOR OR NO-BACK TO _ \ P. LAM. EXTERIOR ALLOW FOR TRASH/REC. • - m 2214" CABINET FINISH m E— C- LAM. FINISH OR o 0 U ,`. 1 0 1 RECEPTACLES TO FIT IN _ : 4 CABINET �"' ( P-LAM EXTERIOR I m I SHALLOWER CABINET PLYWOOD ( 3/4" PART. BD. 1 � J0 m CABINET FINISH 1 j UNDERLAI'MENT MELAMINCONSTRICT ION WI T1-1 CC E INTERIOR 314 PART. BD. = Q i 3/4 PART. SD. F.5...! 4" RUBBER BASE I CONSTRUCTION (TYP.) "` (TVP-) I Q W } � REMOVABLE NOTE: PROVIDE BACKING I 1 ,-- / CONSTRUCTION WITH MELAMINE INTERIOR Z Z � IN WALL AS REQ'D. FOR 1 I WASTE BINS DRWR SLIDES (TYP.) W _ NOTE: PROVIDE NOTE: LL CO MOUNTING - TVP. ALL 1 I RUBBER BASE 4 _ BACKING IN WALL AS IxT-C , CABINETRY BASE, SEE X( FLOOR FINISH TO /// . . . / WA!PROVIDE AS REQ'D.1 FOR DATE FIN. LEGEND ` 1 / REQ'D. FOR MOUNTING \ - I / IE�_� EXTEND INTO B. JX �,` :rte - TVP. ALL tr MOUNTING: - TVP- ALL 05/23/2018 I • f SUNBELT PLASTIC "PF NG IN /\ CABINETRY CABINETRY SCALE -1-\ r `t ,� -11-1f=7:-"N 2 3/4" CAN TOE KICK" 22" 3" �� 21I,z, �` AS NOTED \- 2� 1'7 1, a BNSLEGEND 'I/ MGR HHL I. BASE, SEE 3 29�" 1/16" / 23 z / 291/2" FIN. LEGEND / 7 31" f 2" X WOOD BLOCK 1 I 2" X WOOD BLOCK JOB CEN014 OPEN BASE CABINET S. SURF. WASTE BIN SECTION (T'I'P.) NO—DRIP EDGE DETAIL BASE CAB. WI DWRS. S. SURF. BASE CABINET SOLID SURF. SHEET 0 ., 0 4" 5" 1i!Mil 6" 4 _ = 0 4" 8" 16"IIIIMIMIMMI D-WASTE-LOW2 SCALE: 3" = 1 '-0" 0 2 4E e,„ D-NDRPEDG 14 SCA 1- 1 2' — A.500 SCALE: 1-1/2" = 1 —0 D-084-COUNTER30 SCALE: 1 1/21 0 LE / — 1'-0" D-084—DIC SCALE: 1 -1/2" = 1 '-0" 0 4 8" 16" D-0$4-DIA OF SHEETS HDL DESIGN HEREBY EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IJT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I 25" U.ON REVISIONS BY 25" 25" UDR / (SEE PLAN) / /2 1 / PLASTIC LAMINATE- (SEE PLAN) SQUARE EDGE 0 DjPC 3/4" SEE FIN. LEGEND, CONTINUOUS SPLASH AT ,J SCRIBE TO WALL AT SACK 3/4�� P-LAM- SEE FIN_ LEGEND, �� I / •COPED LAM. SPLASH I CAULK SCRIBE TO WALL AT SPLASH WATERFALL EDGE SEE FIN. LEGEND, P-LAM - COVED LAM. �r WATERFALL EDGE �' /..L7 ---2 /4 -SCRIBE TO WALL * / 1- " �� d2" TALL SINK RAIL SPLASH '- ` 2 X �a , �,-,1- I/8" X' �I Q rYl1. SCREWED TO CABINET • _ \� SINK f -` SIDES - COVED LAM. WATERFALL EDGEC cr k. s _ 1 \jp-LAM. MELAMINE OR ; , '4 �(s WET COUNTERTOPS) _ 1 I - ZEXTERIOR iii �/ !� CABINET FINfSH 0I x' xt�18 � 3/4" PART. BD. �� < 1/4" PLYWOOD O a .o Y t MIN. CONSTRUCTION (TYP.) 1-1/2" ,_ - aoco 2 PULL - SEE R_ • �` HARDWARE LEGEND {'/� t w `(0 o ' I DR SLIDES a� M4;, 5O oz h p I I 1f r v4° PLYWOOD x Q N . „ ) 0 - � WHEELCHAIRP-LAM INt1= MEDIATE \ vvE I SUPPORTS AS REQ D. t P. LAM. EXTERIOR U o _ z z ACCESS CLEARANCE `^ - J (9 > ". F _ -/ ! E E (DASHEDML REQUIREMENT SEE ELEV'S. �^ v 2214" /�► CABINET FINISH 2 0 a Lim s f 1., n ( 3/4" PART. BD. o CI _� - CONSTRUCTION WITH Z ,n r FINISHED CABINET - MELAMINE INTERIOR 14i11 FACE BEYOND ( P-LAM EXTERIOR �r ■ T -E. CABINET FINISH "' (TYP.) m _ /11 6" RUBBER BASE I MAX. I BEYOND 4" RUBBER BASE - _p SLIDE5 [ '� " '�C �' dc Ni j' NOTE: PROVIDE SINK NOTE: PROVIDE BACKING _ NOTE: PROVIDEHEATHER H. LARSEN it 11 THAT ALLOWS FOR IN WALL AS REQ'D. FOR BACKING IN WALL AS I /-1r GD SPACE BEHIND MOUNTING - TYP. ALL = REQ'D. FOR MOUNTING r �; !l REMOVABLE PANEL. / CABINETRY BASE, SEE tr TYP. ALL ROSEVILLE, CALIFORNIA_,. 1'-5" FIN. LEGEND r ` CABINETRY - 5. ARI-11468 / NOTE: PROVIDE / yT EW.12-31-1S 2). 24" / MIN. BACKING IN WALL AS ' � (27 � 22" J 3" �G REMOVABLE TRAP REQ'D. FOR MOUNTING ,. = f 231/2" { / BN. LEGEND OF COVER SCREEN, NO - TYP. ALL / / SHARP EDGES CABINETRY 3„ \ 2" X WOOD BLOCK LAVATORY SECTION (MOTHER'S RM.) OPEN BASE CABINET' (MOTHER'S RM.) BASE CAB. W/ DWRS. (MOTHER'S RM) Z461.6.1m6:''' Lc, � � ' " = ' m 4" 8" D-084-COUNTER30.2 SCALE: 1 -1/2" = 1 '-0" D-084-D1 D-PLAM Q SCALE: 1 -1/2" = 1 -0 D.SNK.TS.LAYS SCALE: 1-1/21 -0' Wryimii3 giG -J M 30" U.ON. 30" U.ON. co / (SEE PLAN) / J (SEE PLAN) Z SQUARE EDGE SQUARE EDGE Z J 3/4')/ P-LAM- SEE FIN. 3/41 a P-LAM- SEE FIN. 11111 U LEGEND, SCRIBE TO LEGEND, SCRIBE TO - e \ WALL AT SPLASH 1 WALL AT SPLASH _a- I ` SQ- JOINT WATERFALL EDGE II SQ_ JOINT WATERFALL EDC:E . / .7 / , 1 I-1/2" _ - . , _,� X - '- 1%8" /� L `I/S" Z4 \ _ 24" DEEP BASE CABS. - DRWR SLIDES_ _ I PER NOTES �, PULL 1/4" PLYWOOD t { 1/4" PLYWOOD \ I t L - SEE Z - --,\ SHELF STANDARDS - `�( = ALRDWARE 0 r DRWR SLIDES (2) ADJUSTABLELEGEND 2 SHELVES Q ( P. LAM. � - P. LAM. EXTERIOR m I EXTERIOR W CABINET m CABINET FINISH m FINISH ( 3/4" PART. BD. W 24" DEEP BASE CABS. / ;r CONSTRUCTION ( 3/4" PART. BD. / m WITH MELAMINE D CONSTRUCTION WITH PER NOTES ' INTERIOR ,, - N MELAMINE INTERIOR _ (TYP.) �' N (TYP.) DRWR ID _ N. 111.1%e _ NOTE: PROVIDE NOTE: Z'''l _ CPROVIDE BACKING IN IBACKING !N EE WALL AS REQ'D. FOR ' / \ \ WALL AS REQID- FOR MOUNTING - W r-,,._......A - MOUNTING - TYP. ALL `t TYP. ALL ' 10 Cr . -X1CA fNT Y B E R CABINETRY (8 261i21F �� BASE, SEE 261i2H �� BASE, SEEZ Q F / 28'2" i� FIN. LEGEND / 2S'2" Jr FIN. LEGEND W Y 0 W O / / / 2" X WOOD BLOCK 2" X WOOD BLOCK J BASE CABINETS (a TRAINING RM) BASE CAB. W/ DWRS. (TRAINING RM) SCALE: 1-1/2" = 1 '-0" D-084-D1 D-PLAM30 0 SCALE: 1 -1/2" = 1 '-0" D-084-D1 B-PLAM30 1 co — N 25" U.ON. / (SEE PLAN) 20" e PHONE ROOM CONTINUOUS SPLASH / / SQUARE EDGE AT BACK I SIDES 25" 0 MOTHER'S ROOM CONTINUOUS SPLASH AT SEE FIN. LEGEND, BACK 4 SIDES 1/2"�`7/ / P-LAMINATE -SCRIBE TO WALL e SPLASH WATERFALL EDGE SEE FIN. LEGEND, P-LAM En �� -SCRIBE TO WALL e 1-1/2" 3/4 Vii- SPLASH ,1, , , , , , , , , , , _ ` 1,B" J -� / WATERFALL EDGE X - i; s `t /r/ - - - � - DRIB SL_D� W S Q / ' PULL - SEE NL - - - - - 1-I/2 HARDWARE LEGEND CC 221/411 O --I P. LAM. CABINET FINISH d W X tu 3/4" FIXED SHELF CJ) P-LAM INTERMEDIATE < PART. SD. Q SUPPORTS AS REQ'D OR _ CONSTRUCTION WITH / 1 END CLEATS AT WALL. fi P-LAM FINISH V SEE PLANS FOR 0 LENGTHS. I m\ Q I/4" PLYWOOD W/11 . t P-LAM I EL 4" RUBBER BASE 4" RUBBER BASE t, LU NOTE: PROVIDE NOTE: PROVIDE BACKINGX / BACKING IN WALL A5 DATE 05/23/2018 IN WALL A5 REQ'D. FOR REQ'D. FOR MOUNTING MOUNTING - TYP. ALL - TYP. ALL SCALE AS NOTED 4. CABINETRY BASE, SEE \ ‘1 \- CABINETRY BASE, �� FIN. LEGEND 232" SEE FIN. LEGEND MGR NHL it FRT WOOD BLOCKING joa CEN014 SIT-DOWN COUNTERTOP BASE CAB. W/DWR. + OPEN SHELF SHEET 14SCALE: 1-1/2" = 1'-0" D-084-COUNTER SCALE: 1-1/2" = 1'-0" 0 4 S A-501 D-084-D 1 B eineiMMINEMi WDRAWER OF SHEETS " HDL DESIGN HEREBYI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE +I TO 8E REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. 1 OPEN OFFICE ::.:.....:........ :.::::::::::::::::.. REVISIONS BY :. r CA� � �,�T �ARD�.AR� ACC��SC�RI�� � G��� _ .: : : � P � _ 1�� � D _ ; 4'_5 FE / 3' )11�° HARDWARE MANUF. PART/ DESCRIPTION FINISH REMARKS KEY ITEM MANUF. MODEL FINISH REMARKS 5U 1ED BALLED 05/23/18 I BIDSET/ PC Y/// CABINET PULL HAFELE 4" WIRE FULLS SATIN CHROME INSTALL HORIZONTALLY AT DRAWERS AND VERTICALLY AT AUTOMATEDCABINETS AED EXTERNAL TBD TBD WALL MOUNTED ABOVE FIRST AID KIT CTFTI) TENANT TENANT / DEFIBRILLATOR DRAWER SLIDE ACCURIDE AC3832-20 SATIN CHROME GCs-I / BY TENANT, PROVIDE DUPLEX GFCI RECEPTACLE 4 WATER LINE "l Ll ! HD DRAWER SLIDE ACCURIDE 1951 HEAVY DUTY 28" SATIN CHROME FOR 30" DEEP CABINETS CM COFFEE MAKER (TFCI)BREAK 4 COFFEE ROOMS ANT CC�ITRJaCtcR it COPY / -4- �U i EUROPEAN CABINET HINGE SLUM BH 1315580 SATIN CHROME CV`s EVAC BOX TBD TBD TBD SY TENANT TENANT TENANT 120 DEGREE OPEN/ SELF CLOSING + `' / i - AMERICAN PEKOE SEMI-PROFESSIONAL SINGLE HOLE STAINLESS u / - HEAVY DUTY BRACKETS KNAPE 4 YOGI KVI81LL 14" OR Is" ANOCHROME OR PEG 4 HOLE F FAUCET STANDARD KITCHEN FAUCET ••4332350 STEEL (PVD) BREAK ROOM 4 MOTHER'S ROOM CQLTR�GrCfz CCHiRa7Gro M \ L O HEAVY DUTY STANDARDS KNAPE 4 YOGI KV81 12" LONG ANOCHROME PROVIDE WALL SACKING OR PEG t HOLE FA FIRST AID KIT TBD TBD TED TENANT FURNISHED 4 TENANT INSTALLED. SEE DETAIL 9/A-100. TENANT TENANT // SB MODEL "534'B-2150DM-2, DOUBLE BOTTOM HID312A-I COUNTERTOP NUGGET ICE DISPENSER W/ 12 RECIUIRES M11(6'CLEAR4NCE AT ALL SIDES. PROVIDE REWIRED / BRUSHED/ WHITE INCLUDES FULL-EXTENSION SOFT CLOSE BALL-BEARING SLIDES 4 2 20 ■ n E / b / PULL-OUT TRASH INSERT REV-A-SHELF MOUNT WASTE CONTAINER DOOR MOUNT KIT COUNTERTOP ICE J LB STORAGE, 1625"W x 2438"D x 35" ELECTRICAL,WATER SUPPLY AND INDIRECT DRAM PLUMBING. r / I4-13/16"W x 22-15/16"H x 22-I/8"D, 19LBS. ALUMINUM PREMIER DOUBLE 50 QT WHITE WASTE CONTAINERS IWp SGOTTSMAN CGNiR�c-TGR CLN1RaCiC? O ,^n �'; nl WATER DISPENSER 115 V/60 Hz/1-PH,1A,4-9 kW,3,200 BTU HEAT INPUT, PROVIDE_ SSMI-P SINGLE PRIMARY WATER FILTER CARTRIDGE 5 2 va 1.5 Ft.CORD AND NEMA 5-15 PLUG INCLUDED. Y, `�//�� L 6 o ?_2 -,Ti - ; •-600 SB a � It 10 9 LKR1 LOCKER LYON ITEM•4JXG5,2 15"W x }5'D x 18"H,W/OUT ADA SHELF METAL/ DOVE MOTHERS ROOM.CFCI 'T� RdGTpR v I C o I RII V I TYPICAL NOTES A-501 A-501 TIER MODEL VD5252SU GREY - M 7 ' 2 LYON ITEM 04JXC5,2 METAL/ DOVE n n / ACCENT 2'-0" 2'-0" LKR2 LOCKER TIER MODEL 'DD52525J 15"W x 15"D x 18"H, W1 ADA SHELF GREY MOTHER'S ROOM. CFCI CONT CTCR rcR Q cc n ._ ts `4 PT-5 WALL •••••• ` S 0 0 c f0 �O L f (,) / v v O PT-I -011 I �, 9'-01I HANCOCK MIRROR, MHE1083t, 28"W x 34"H x I"D BRUSHED 01 O1 CEILING CEILING M1 MIRROR MDC MOUNT BOTTOM OF REFLECTING SURFACE AT BRIGHT MOTHER'S ROOM, VANITY MIRROR ABOVE SINK CCNTR4CTCR CaliteAclaR _J j u. � c a 8 ' / ,c, RB-I .40" AFF MAX- SILVER += x .t-\--/(' INSETt ^ a I / REG Q CPT-1 PT-2 BRUSHED ` ` o ��i n TYP- HANCOCK MIRROR MHE1084± SILVER. Z ■ - BRIGHT MOTHER'S ROOM,FULL LENGTH MIRROR o SILVER TYPICAL NOTA DECORATIVE M2 MIRROR SIZE: IS"w x 54 H x 1 D ILvE � i 2 1 ri � Z w / C O 6 ®CSRELOCATED CABINETS E PT-5 PENDANT • MODEL JES20515NSSGE, 13.25"H x 24.{25"w x 13.5"D STAINLESS Ai? O '( LIGHT MW MICROWAVES (2) GENERAL ELECTRIC 2-CU Fr, 1 00 WATT STEEL PROVIDE (1)NEW DUPLEX GFCI RECEPTACLE (CPC!) 20 aNTR4CTCR CiNR -TGR ' '`[S`- I U ¢ PL-2 PP 4OPUTIR(N) j,cENTEIR ON COUNTER`FIXTURES PURELL HEATH H. LAR�I�j ► ` TENANT TENANT O iv PD DISPENSER MOUNT PER II/A-500 (TFTIJ �..� PL-I SHELVES (E) PL-2 PAPER TOWEL •,,.-co - V-- COPYe c. �� PTD DISPENSER TED TED TED I TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANT RbSEV1LLE CALIFORNIA,. 1 _ i / Q / \ 1 3 TI ii SI SINK ELKA-7 LUSTERSTp �LIJHAD281645,SIZE: 309�i" x 18�ia" x STAINLESS UNDERMOUNT AT BREAK ROOM �r EXPARI-11468 .121 16$ O / U / 4" I 1 33�� 4' � I � � 33��� 4�" SINGLE BOWL STEEL CL7 tiRA:TC�R GCt�1RtCTC� V �� - _ _ COUNTERTOP }s - _ - ,rte COUNTERTOP CELEBRITY ADA-COMPLIANT SINGLE Bowl SINK STAINLESS OF / I I \ 52 SINK ELKAY "DROP-IN" AT MOTHER'S ROOM CR p CR / 86 -NEW FINISHED - ' • _ "rsECR2521 STEEL . I END PANEL I I I I I PL-I SB SHRED BIN TED TBD TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANT 4la • ' ILI -5" 3' 2' TO MATCH (E) RB-1 I REC �TR - --is ___ SD SOAP DISPENSER TED TBD TED I TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANT r- �/ / i r` I 1 I LAMINATE , 0 _0 I , y N 0,-0�� REC RECYCLE BIN RUBBERMAID OR E . 23 GALLON TBD TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANT Z GCs-1 4 1 I I I STAINLESS RELOCATE EXISTING REFRIGERATORS FROM PREVIOUS UOP 4 : ijj Q.FINISH FLOOR FINISH FLOOR REF REFRIGERATORS(2) EXISTING EXISTING CCMRACTCR CGNiR4CCR �,, +/-4'-I1 3/4" 2'-101a STEEL CENTENE BREAK ROOMS NoC,,, Q -1\--////v//7,/�r ..s.....:: \ 2'-2 1/2" I'-6" 2'-2 1/2" I'-I1 3/4" ( COPIER) '-0" / 8 ,� 3'-0" TB TAGKBOARD J TENANT FURNISHED t TENANT INSTALLED TENANT TENANT i` / 'i / 1/ LL-OUT TRASH t 1" TR TRASH BIN RUBBERMAID OR EQ. 23 GALLON TBD TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANT -i O OPENOFFICE3 � 1° I la J � RECYCLING CABINETS ADJUSTABLE SHELVES BLACK 4 TSTR TOASTER COFFEE PRO MFR MODEL •OGFOG8166, STAPLES ITEM •982841 STAINLESS TENANT FURNISHED 4 TENANT INSTALLED TENANT TENANTZ E cd 0 Z c2 O ENL. PRINT RM 534 PLAN ENL_ PRINT ROOM 534 ELEVATION ENL. TRAINING ROOM 523 UNDER COUNTER U-LINE ADA SERIES STEEL REFRIGERATOR •ADA24RSI3, 53 CU. 24"W x 23.25"0 x 32"H STEEL ESS PROVIDE I DUPLEX GFCI RECEPTACLE (CFCI) 0 cairfucraR W41RCCTR La Q SCALE : 1/4" = 1"-0"" 0 SCALE : 3/8" = 1 '-0 CABINET ELEVATION SCALE : 3/8"" = 1"-0" FT. (� /��/ ENLARGED PLAN SHEET NOTES - 0 r BREAK ROOM I 6'-2" O NEW MICROWAVES (MW) BY TENANT. i' 7 2. NEW COFFEE MAKER (CM) BY TENANT. PROVIDE PLUMBING. WC-1 ACCENT WALL (WET WALL) }� tI I �y p PT-6 ACCENT WALL / • \ / I IO I I-IER'S ROOM SIM. TYPICAL. NOTES SEE PLUMBING PLANS. PT-15 "WINK" WALL 3. RELOCATED PURELL DISPENSER (PD). PT-f0 Q © 4 00040a A-501 A-501 A-501 A-501 PT-I HALL i / RB-I 4. SEE INTERIOR ELEVATIONS FOR ADDITIONAL FINISH R5-1 TYPICAL NOTES / 6° LVT-2 9 0 MATERIALS/ INFO. SEE FINISH LEGEND SHEET A-500. CEILING LVT-1 ♦0♦ II TYPICAL NOTES 5. NEW 31" DEEP COUNTERTOP WITH 291/2" DEEP BASE CABINETS. LVT-2 000 ,A a' 00000 -PT-I0 ,PT-10 I DESIGN TO SUPPORT LOADED ICE MAKER + 200 018. LVT-3 _ II ( T_2 7 0 r Ml 6. SEE EQUIPMENT LEGEND ON THIS SHEET FOR KEYED ITEMS. / 11 1 [. _ _ . -41 \ �` :� ,4,>„„•,"...K.),,,•,>,>,,,1 LKRI KR2 6,-0„ OVIDE POWE AND PLUMBING AS REQ D FDR ALL EQUIPMENT. W PR R " Ml I PL-2 SEE ELECTRICAL AND PLl1MBINCs DRAWINGS. EE T MULTI-PURPOSE M2 MIRROR (M2) Q } , / ROOM 6' ), - - ' +40" MIN. 1. PROVIDE AND INSTALL NEW C-FOLD SSTL PAPER TOWEL t`�j - BOTTOM of V DISPENSER CPT). MOUNT WITH DISPENSING SLOT AT +40" AEF. `�' ( 10 MAX. ON WALL, WITHIN REACH RANGE. LC11 I �� 'y \ �- a r-- MIRROR � � -2 = x PL IvE > , r lb Q ,� ' 1 CR I PT SURF1REFLECTACE ACCESSIBLE 8. LCX.ATIGN KFIT(2A)TIREL448CCA" TEDREFRIGER"4T01 i. GGTDVERIFYWIDTH6. N> aocp A ' ' F ,�� 331,2 ( ( LOCKER W/ 331,2�f ■} ■ Sl-IEL1= +35 9. FIRST AID MAX TO TOP WITH "FIRST AID" SIGN AB01/E. f 11 g! Ill: 600 tt - UCR 3. 51 1 COUNTERTOP r __ COUNTERTOP > W11 UCR 0 -___2! \ 7c } PL-I PL-1 10. 30" X 48" WHEELCHAIR ACCESS APPROACH TO SINK : U > B LKR LKR - OPS / / ry"` tQ.- >} t M2 - - '-- I1. CONTINUE SPLASH AT SIDE WALL. /i7, 7///////7/ ////i//// / irk ' _� R15-I ( slH RB-1 Y TYP_ _ii 12. TENANT TO PROVIDE ADDITIONAL FREE-STANDING SOAP 1 2'-1" I 1 0'-0" II � I c 1 ... 01-03 } 1 i y FIN151-I FLOOR FIJR1�1. BY TENANTS 2'-1" FINISH FLOOR DISPENSER (WITHIN 24" REACH RANGE) IF NEEDED BY STAFF Z 3 F } A OPEN OFFICE 2 4'-1 3/16" 10'-0 1/8" 1'-6" 2'-1" 3'-0" 1 / MEMBER. • W / " 4'-1 3/16.. 10 0 1/8 13. SEE PLUMBING PLANS FOR INDIRECT DRAIN FOR ICEMAKER/ } 11, 1" III 1" I" / / /� ..1 > U CI <1:::: WATER DISPENSER y A NORTH l al WEST 14. PROVIDE AND INSTALL ICE MACHINE/ WATER DISPENSER (OD). } › -._ .< - PROVIDE PLUMBING AND POWER AS INDICATED ON ELECTRICAL I �� T-2 I 41) AND PLUMBING PLANS. 17-- E ® 6 ENL. MOTHERS ROOM 540 PLAN ENL_ MOTHERS ROOM 540 ELEVATIONS SCALE . 3/8" = 1"-0„ CO_ I " 15. SEE ELECTRICAL PLANS FOR ALL POWER 4 COMM. OUTLETS. N } I SCALE 1/4'" = 1`-0 16. PROVIDE ACCESSIBLE CONY. DUPLEX OUTLET ON SIDE WALL. GG-1 SEE ELECTRICAL PLANS. /////� CCs-I J 5'-h° 11. FURNITURE BY TENANT. > ( ® ed-al) , , 18. RELOCATED LGD 5G N l Y T A--- r �1 1 14 12 TYPICAL NOT REE B TENANT). l 19. NEW PURELL DISPENSER (PD). (TETT) EC 1 0 , -\- i /////// -,//// ,� `' �A-500/ A-500 A-500 I , . _ 1 \� ••••• 8 20. GFCI = CONTRACTOR FURNISHED, CONTRACTOR INSTALLED, TFTI = W CO / CENTER ON COUNTER m 6 ® TENANT FURNISHED, TENANT INSTALLED. (NO APPLIANCES OR J A-500 A-500 A-500 A-500 FURNITURE ARE PROVIDED BY LANDLORD). (n II y1DECORATIVEHTFIX- PENDANT 2 -0 2 -0 _O / 111" 9'-0" LIGHT FIXTURES/ . AI 4,91-0" 0 z Q / �1 I� CEILING CEILING 21. NEW TOASTER (TSTR) BY TENANT. M < + W 12 / 22. PROVIDE (2) DISABLED ACCESSIBLE TABLE LOCATIONS 0 ,. B , _600A i TVP. O PROVIDE ISA STICKER ON TABLE AS REQUIRED. 0 W co- - � CC 0 CL Z `- TWD ,CO 0 PT-I WC-7 23. ANCHOR LOCKERS TO BACKING IN WALL OR STUDS. O v '_ �� �� =----I9 CABINET ELEVATION NOTES: C W I CM 0 ® _rli'ff i.'. COUNTER SS-I - - i 11WD 1II 1 W W IO O� y t SPLASH REF i i REF SEE CABINET HARDWARE LEGEND, THIS SHEET. Q 0 / - COUNTER ..04, �'---I� 0 J �F "' t SPLASH 55-1 I --\ ---� 6+40" r---� �I� �Id 2. SEE EQUIPMENT LEGEND, THIS SHEET. 0 Z W F / __ • 1 PAPER 1 1 so m n n 111 0 \ I o O I�rrill irii1 PT i t---� rri'll-j ���il TOWEL DISP� i i -1 l IIIIIIIII U U IIu1 / >1 II If I� L---J Ir$TR1 II 11 • L J L_J Mn===i4 O a 20 CMI__ „ 3. SEE A-500 FOR FINISH MATERIALS LEGEND. W . ,... / 1 1 1 " _ 4. SEE PLUMBING FOR WATER LINES 4 DRAIN. + Q 33 2 J��1_---__I__; IL----_IL1 1 33/2 , 1 YJP � �' 4-P ////////V 11111 / COUNTERTOP 11 1 1 4 1 COUNTERTOP I - s� - - 7.-- 0 . - /////j/\ _ _ IIS _ _ �_IN < o w 0 rt �� �� CABINETS PL-1 I I CABINETS PL-1 5. CAULK JOINTS BETWEEN COUNTERS AND WALLS, TVP_ t O 2 -I 2 -11 H / \ k` I Z o ..1 Q \ CG-I I OPEN - \IREGI TR - 2'-5" OPEN - / ---- . - - - -- W W REF �5„ CG-1 I I I I -- 6. P-LAM TRAP SCREEN REMOvABLE PANEL. CONTRACTOR OPTION �/� TO PROVIDE VERTICAL SWINGING PARTIAL HEIGHT DOORS W/ ,.Ci( ® ;r -I(>1- • I 4 T III MAG LATCH TRAP SCREEN. DATE 05/23/2018 11.+6 in INISH FLOOR FINISH FLOOR - ' /,,,.,, }� 3' 2'-4 1/4" 3' 3' 1'-11 1/8" 1'-11 1/8" 3' 3' 1. PROVIDE 51LICONE BUMPER PADS / SILENCERS AT ALL CABINET SCALE 1 / / � / / r 1I, DOORS 4 DRAWERS. 1° 31-8" I'-6 3 16 31-8" 1 ___9 ' / / AS NOTED z ,.,.. .� \ RUBBER BASE CxAP W/ Z-PLATE RUBBER BASE PULL-OUT TRASH CABINET ADJUSTABLE SHELVES MCR HHL .144 / 8. SEE DETAIL 4/A-"100 FOR DEVICE 4 ACCESSORY MOUNTING ,.. MIVA:: 0 `: ...< A SOUTH RB-1 B B NORTH RB-I 6 HEICcHTS A... �, UE d ON BEYOND 4 ON 2'-l" . ?r. 16'-11" 5'-5" / 13'_4" Jr CABINET SIDES. CABINET SIDES. - JOB CEN014 / 7. TRASH 4 RECYCLE SIGNS BY TENANT. SHEET' 0 ENL. BREAK ROOM 522 PLAN SCALE : 1/4" = 1"-0"" ENL. BREAK ROOM 522 ELEVATIONS SCALE : 3/8" = 1 '-0" A-600 , I I OF SHEETS HDL DESIGN HEREBYI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS- THESE PLANS AND DRAWINGS ARE +I TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. NQTES REVISIONS BY 111- 11I. AT LEAST ONE ACTIVE LEAF OF DOORWAYS WITH `,../ 05/23/18 r� TWO LEAVES SHALL COMPLY WITH THESE _ _ NOTE: INSTALL ELECTRICAL AND TELEPHONE BIDSET/ PC 48" CLR MIN. f` DETAILS. —I' NOTE: ALL MULTIPLE \ - -FE SIGN (CENTER ABOVE FE) WALL OUTLETS AND SWftGHPLATES AT i l ( > I` 2. DOOR OPENINGS SHALL PROVIDE A CLEAR GROUPS OF NEAREST STUD FROM SCALED LOCATION ON WIDTH OF 32"MIN.MEASURED 6ETWEEN THE FACE SWITCHES, DIMMERS, I PLAN UNLESS SPECIFICALLY DIMENSIONED OF THE DOOR AND THE STOP(WITH THE DOOR EDGE OF WALL CCG- WHERE / \ OPEN 9m"J. THERE SHALL 5E NO PROJECTIONS ETC, SHALL BE il �f OCCURS - NTO THE REQUIRED CLR OPENING WIDTH BELOW HORIZONTALLY / 34" AFF.PROJECTIONS NTO THE REcLIRED CLR 0 "4 GANGED LESS AT 34" TO S0" AFF.MUST BETH ~4 i AND PROVIDED WITH \ POOR A COMMON COVER FRAME �-. 3. FLOOR SURFACE AT MANEUVERING CLEARANCES PLATE. FIRE STROBE SHALL BE LEVEL AND CLEAR LEVEL CHANCiEs I- LIGHT SWITCH (LESS THAN 4" AT THRESHOLD5 SHALL ESE PERMITTED PER THERMOSTATS SHALLSCHEDULED DETAIL 6 THIS SHEET. DEEP) BE INSTALLED DOTTED DSR �- _�� ! r E 6 -� 32 CUR. INDICATES LOCATION 0 Ill - DIRECTLY ADJACENT \ ' MIN. ' OF LARGER PLATE LIGHT SWITCH p o 0 SWITCHES, U.ON. '� _ 3 f HINGE - - LATCH FOR GANG SWITCHES 6E DOTTED LINE 6 L 4 �, 4$' CLR Mik ! FRONT APPROACH, FRONT APPROACH, APPROACH, APPROACH. / / / / — lJ PULL SIDE FULL SIDE PULL SIDE PULL SIDE C ° v yf IUDIcarES LocATION (/� C ) d ORFIREALARM "' "' CZ OF LARGER PLATE - I I a) LU FOR GANG SWITCHES \ n n / / r v PZ \/ u PULL STATION Q N a LATCH i '-'s a) / / ci U 1 36" CLR IN z APPROACH }' ~ THERMOSTAT —�� U E 7 \ 1 \ 1 \ f '--- o -1F- -IF 0 9 18" CLR 18" CLR \ HINGE = E < cU WARE SET ASHASCHEDULED REDUCED x a 0 si El i i 6 0 a MN (ADD MIN (ADD 24" CLR. U 4 24" CLR s Q 0 _ `� �. L 6" AT EM. \ 61 AT EXT. \ MN.LATCH Ul MIN LATCH / X N Q a 1 ,....„ gm SIDE OF 9� SIDE OF SO 1 APPROACH APPROACH d -' 2 " / ,- Ti EXTERIOR EXTERIOR x y 8„ 41 B _ BRACKET 4 �� . _E V DOORS) .. DOORS) v I MOUNTED FE. OC / lir (SURF.) E ] 'lit •_I ,, 6 �, VER W/ A. 1 32" CLR 32" CLR. C 12" x> 22" CLR 32" CLR 24" CLR a 22" CLR. i�6"� 32" CLR ELECTRICAL r O U p RDWARE / .c0-D 490 MIN. CLR MIN. 'GLR. ' MIN.HINGE �� MIN. MN.LATCH p P ' MN.HINGE M . 0 Q '" N% z `•flN FOR IN. APPROACH APPROACH F 5 3 APPROACH OUTLET------- _ i N HEATHER H. LARSEN DOOR DOOR sY a , FIRE 0 d ›X' :�_t-{ 48 CLR MIN. tX U �„ Q . . ( ) 1 LOSER GLasEJJITH \ EXTINGUISHER ex 4 / U E U HINGE = WALL g R05EVILLE, CALIFORNIA 2 /� 4 LATCH /N, I LATCH �' CABINET - _ d ARI-11468 O ----.. i ' HINGE > LATCH A APPROACH TELEPHONE r m 9 EXP.12 31 18 I4 I APPROACH, APPROACH, cv FRONT APPROACH, FRONT APPROACH, PUSH SIDE PUSH SIDE J OUTLET E V '93 3 Tc OF d'"# PUSH SIDE PUSH SIDE /11J -14 DOORS 4 GATES IN SERIES PROW APPROACH FRONT APPROACH* 0IDE APPROACH \ '- RECESSED DOORS 4 GATES LU DOOR MANEUVERING CLEARANCES TYPICAL MOUNTING HEIGHTS SCALE: 3/8" = 1 ' d"0 D.DR.CLR 4SCALE: 3/4" = 1 '-0" 0 MTG.HTS 2LIU Q 5=' L O 1.FLOOR OR WALL ASSEMBLY - MIN 4-1/2 N. THICK LIGHTWEIGHT OR NORMAL WEIGHT 1100-150 PCF) STEEL STUD MANUFACTURERS ASSOC. ICC REPORT ER-443P CONCRETE.WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCI3ETE BLOCKS.MAX DIAM OF �' Z 2 1/2" MAX. THROUGH OPENING 15 12-1/4 IN.SEE CONCRETE BLOCKS (CAZT)CATEGORY IN FIRE RESISTANCE DIRECTORY O O I �1 � Z CC AT 1:2 SLOPE 216""x25 GA.MTC. STUDS 0 24" D.G. (2505125-15) (MAX- HT. 10'-1") FOR NAMES OF MFG'S. J 2 "x25 GA. MTC. STUDS m 16" O.G. (2508125-18) (MAX. HT. 11'-3") 2. THROUGH PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER la(1) < 3%,"x15 GA MTI. .TUDS * 16" O.G. (362 125-15) (MAX. HT. 18'-3") CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FNRESTOP SYSTEM.MN ANNULAR SPACE BETWEEN PIPE, / I \ 3 %"x25 GA. MTI. STUDS 24" 0.0. (3628125-IS) (MAX. HI. 13'-5") CONDUIT OR TUBING 4 EDGE OF OPENING IS ON. (POINT CONTACT).MAX ANNULAR SPACE INDEPENDENT ON - 0 co HANG FROM/BRACE TO \ \ 3 5/8"x25 GA. MTC. STUDS € Ib" O.G. (3625125-18) (MAX. HT. 14'-4") PIPE, CONDUIT OR TUBING TYPE t SIZE AS WELL AS THE F RATING OF THE SYSTEM, AS SHOWN N THE TABLE STRUCTURE ABOVE. SEEr-- 3 5/b"x20 GA. MTL. STUDS * 16" O.G. (3625125-33) (MAX. HT. 16'-5") BELOW. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OWALL ASSEMBLY.THE WALL DETAILS 1/4" 3 %"x20 GA. MTC. STUDS B 24" O.G. (3625125-33) (MAX. HT. 14'-9") / / A METAL THRESHOLD SEAL FULL HEIGHT 1U/ b"x25 GA. MTC. STUDS g 16" O.G. (6005125-18) IMAX. HT. 19'-9") FOLLOWING TYPES 1 SIZES of METALLIC PIPES,CONDUITS OR CUBING MAY BE USED: / MAX. A.STEEL PIPE - NOM 10 IN.DIAM (OR SMALLER)SCHEDULE 10 (OR HEAVIER)STEEL PIPE. PRINTABLE SEALANT AT ALL 6"x20 GA. MTL. STUDS 6 16" O.C. (6005125-33) (MAX. HT. 21'-1") B.CONDUIT - NOM 6 IN. DIAM (OR SMALLER)RIGID STEEL CONDUIT. (E) TI-!R! GRID MTL. STUD WALL GAPS. b"xI6 GA.MTC. STUDS 16" O.C. (6005125-54) (MAX. HT. 30'-0") C.CONDUIT - NOM 4 IN. DIAM (OR SMALLER)STEEL ELEC.METALLIC TUBING OR STL. CONDUIT. / TO REMAIN b"x16 GA. MTL. STUDS e 12" D.C. (6005125-54) (MAX. HT. 321-6") D.COPPER - TUBING NOM 3 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER)COPPER TUBING. I 1 r COMPRESSED CARPET IP 1 6"x16 GA. MTL. STUDS 6 12" O.G. (6005200-54) (MAX. HT. 34'-0") E. COPPER - PIPE NOM 3 IN. DIAM (OR SMALLER)REGULAR (OR HEAVIER)COPPER PIPE. �• 1/4" MAX. BELOW / PROVIDE AND INSTALL ANOD. 5"x18 GA. MTL. STUDS A 16" D.C. (8005125-43) (MAX. HT. 34'-4") F. IRON PIPE - NOM 10 IN.DIAM (OR SMALLER)CAST OR DUCTILE IRON PIPE. I THRESHOLD ALUM. CHANNEL TO MATCH — STOREFRONT. NOTCH AND DESIGN BASED ON 5 LBSJ SF LOAD 4 MAX. L/240 DEFLECTION COMPOSITE WALL PIPE CONDUIT MAX NOM PIPE CONDUIT F RATING HR MAX ANNULAR' ADJUST. TRIM AS REQUIRED SHEATHED W/ MN.X�" GYP. WALLBOARD BOTH SIDES W/ *6 SCREWS m 12" O,G MAX. OR TUBING TYPE OR TUBING DIAM IN. SPACE IN. FINISH FLOOR EVEN ABOVE AND BELOW WINDOW 2-1/2 1/2-12 3 3/4 Z NEW SUSPENDED , 401 OPENING. METAL STUD SCHEDULE ° ACOUST I GAl_ 2 1/2 !2-12 3 3/4 CEILING 1' t V )1-.__ :-;:::::-i4-1/2 1/2-6 3 1-1/2 S �_ �� SCALE: NTS MTLSTSCH2 4-1/2 LI- - CIIlIlllll IIILILILILILILI 3' CEILING HT. 1\ THRESHOLD - 4-1/2 12-20 3 3/4 W 1 ` PROVIDE2" WIDENEOPRENE 2 1/8 I �� j 1 1 —a, 8 FLUSH THRESHOLD TAPE AT METAL TO METAL 3.FILL.VOID OR CAVITY MATERIALS' - PUTTY - MOLDABLE PUTTY MATERIAL KNEADED BY HAND 4 • CONN. APPLIED TO FILL ANNULAR SPACE TO A MIN DEPTH OF 1 IN.,FLUSH W/ TOP SURFACE OF FLOOR IN -,-- 1\,...:___ WALL ASSEMBLIES, REQ`D PUTTY THICKNESS TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF MATCH HEIGHT OF (E) GLASS WALL. MINNESOTA MINING t MFG CO - MPS-2+ .BEARING THE UL CLASSIFICATION MARKING EXISTING ADJACENT K________________ HEADER VINYL TRANSITION-Th CARP . c4 HILTI X-DNI21 PS SHOT PINS X32" O.G. A ® Q r w NEW 20 GA MTL. STUD VCT METAL BOTTOM TRACK—Th PER ICC REPORT ESR 1663. IIII[ 8 6 CC N HEADER WI 5/5" GYP. BD. • Iraz>`' FINISH W/ L-METAL (E) SILL GONG COMP REF. ` /� • `= y LUL O TAPABLE CORNER TRIM J� I I I I I I I I I I SLAB +000' a a �'; • , I �1< � II� III JIIIIIIIJIIII 1111111111111 . :. W,A. p ATTACH TO FLOOR : . ,i •STRUCTURE ABOVE.ABOVE. VERIFY EMBED DEPTH W/ EXISTING q� MATCH EXISTING EXTERIOR WALL WHERE FLOOR STR REQMT'S. • -�� 8 OCCURS. Z 3 F ADJACENT HEADER S OANG- FLOOR - A ® _ LIU SECTION AA--A cc p RU55ER TRANSMON HILTI FASTENERS cb METAL v SOFFIT/HEADER DETAIL THRESHOLDS WALL TO WINDOW MULLION STUD PARTITIONS F.R CONC. FLOOR PENETRATION 1 rel 6 . 8elliiiil =9 10 1 , 0" 0 I" 2�� 4.. SCALE: 3" = 1 '-0" CLGGYPHD5 SCALE: 3" = 1'-0" SCALE: 3" = 1 '-0" 0 2" 4 8 D-WLMUL1 SCALE: 3 = 1 -0 D-HILTI.FAST4 SCALE: 6" D.CONC.FLR.FR.PENE 1ca FV NOTE: PROVIDE WALL BRACE MAINTAIN (E) BRACING OR USE (N) 3-5/8" X NOTES: CV AT STRIKE SIDE OF ALL INTERIOR 25 GA MTL. STUD BRACES 6 48" O.G. I. RECESSED DOORMAT TO BE I"I DOORS. 18 GA 2" x 2" ANGLE W/ I I \ / _1 (MINrei . 3 - *12-14 SCREWS EA_ END), SEE 1/A5.0 FOR FLOOR CONN. ANCHORED TO PREVENT 114 WIRE HANGER 2 -0.145" x 1" SNOT 4 *' INTERFERENCE WITH WHEELCHAIRS. 4 /+ I +/ I (E) COMPOSITE FLOOR a -• NESTED SLIP TRACK SECURELY PINS OR SCREENS I )- ILL ` STRUCTURE PROJECTION SCREEN 4 d a INTO METAL ROOF (E) ` 2. THE BOTTOM 10 INCHES OF FULL WIDTH d ATTACH TO EXISTING ROOF OF DOOR (EXCEPT AUTOMATIC AND / HOUSING HUNG PER MANUF. a ° q STRUCTURE OR BRIDGING. ABOVE AND 2- '12 5TS 1 5TH ABOVE Q- > INSTRUCTIONS. d INTO BRACE. \ / SLIDING DOORS) ARE REQ'D TO 4 Q PROVIDE BLKG. AS REQ D. 1 �, z r} HAVE A SMOOTH SURFACE AT BOTTOM d a 7 aK CLIP W/ EXTEND 3-5/8" �S 5/8" GYP. BD. TENANT SIDE OF WALL 2'-8" CLR ],_ DOOR PUSH SIDE. STUD WALL a4 4 a TOTAL OF 4- x T.5 GA MTL. STUDS AT 48" O.G. m3. THE MAXIMUM EFFORT TO OPERATE CUT TOP EDGE OF GYP. BD. \ `�F20 GA FLEX TRACK W/ "12-14 SCREWS n I *12 S S ALT. DIRECTIONS 4 BEND TO = MIN. THE AND GATES SHALLNOT STRAIGHT AND TRUE \ UNDERSIDE OF DECK (MIN. 2 rte) * 12" O.C. TO DECK OR SOLID BRIDGING. E CO] '�' `T� 4______ FLUTES PERP. TO DECK SPAN DIR) \ / EXCEED 5 POUNDS FOR INTERIOR J �_ ATTACH W/ (2) DS 21 PID HEAVYAND EXTERIOR DOORS AND GATES. c ERCPA / DUTY PINS TO DECK I L_ �� 3%" X 25 GA MTL. STUDS X24" O.G. CLOSERS SHALL MEET MIN. SWEEP Q SUSPENDED ACOUSTICAL I I I 1 I NAM' / I I I I I 1 1 SCREW TO TOP TRACK OF (E) WALL \ / TIME OF 5 SECONDS TO MOVE FROM CEILINGPEN POSITION OF 90' TO 12" FROM 7 1 - I ,. ` -- WI "12-14 SCREWS g 12" O.C.OG30 W T VARIES WHERE) OGD OCCURS -. --y.1 w 4/11LATCH. + 0 11 ti R-11 BATT INSULATION MATCH (E) 2'-8" CLR Z ' I ' I ' I SEE REFLECTED LAY-IN ACOUSTICAL CEILING SEE RCP (E) SUSP. CLG. HT. l MIN. 4. SPRING HINGES SHALL BE ADJUSTED 0 \ T GLC. PLAN4,_ Y TILE PER BLDG. STDS. lam' SO THAT FROM THE OPEN POSITION 9' OR 10' IIIIIIIIIIII "-_ : 1 1 1 1 1 1 i,fIT OF 10' THE DOOR OR GATE SHALL P R-13 BATT INSULATION ACOUSTIC SEALANT EA. SIDE (E) CLC. I REMOVE (E) L-METAL BOTH SIDES MOVE TO THE CLOSED POSITION IN 1.5 (PROVIDE ACOUSTICAL TAPABLE L-METAL TRIM HIGH WALL USE FIBERGLASS TAPE AT JOINTS, TYP. C ' SECONDS, CO j SEALANT AT BOTH SIDES) (E) CCG. HIGH WALL CO CE _� I =1 5!8" GYP. BD. BOTH i 25 GA. MTL. TOP TRACK l 2'-8" CLR. �, 6" 5. ALL DOORS SHALL BE OPEN- ABLE _S 9' 0` A.F.F. I I 'I I 'I I' �' I' 1 1 I 1 ' I 1 1 ' 1 1 I I SIDES U.ON. MIN. FROM THE INSIDE WITHOUT THE USE OF W co A KEY OR SPECIAL KNOWLEDGE. ti 3 5/8" METAL STUDS /� 3-1/2" ACOUSTICAL BATT INSUL_ -1/-- 1,---- f I-_ 0 Z g 24" O.C. SEE MTL. STUD V .�_ 6. LEVER HARDWARE HANDLES SHALL 0 0 CANTILEVER SCHEDULE t` T-RAR AS REQ'D. 3-5/5' MTL- STUDS PER METAL 1 RETURN WITHIN 1/2" OF THE DOOR 0 0 STEEL RUNNER STUD SCHEDULE : / \\ FACE. OPING. AS REQ'D. 1, /k7/ RUBBER TOPSET BASE 1. ALL DOORS SHALL HAVE MN. CLR TO CONCEALSEE FINISH SCHEDULE U.01�1. - 25 GA STEEL RUNNER - 25 GA. TRACK - SECURELY 1 LEVEL LANpING DIM. OF 60" IN THE DATE FASTEN TO CONC. FLOOR " 05/23/2018 ,,i ') NOISING / SECURELY FASTEN TO CONC. '� EJ SWING DIRECTION AND 48 IN THE PERIMETER T-BAR FINISH FLOOR SLAB. SEE 2/A-101. FLOOR SLAB. SEE HILTI FASTENERS OPPOSITE DIRECTION WITH 18" CLEAR scALF AS NOTED ANGLE- FINISH OPEN BOTTOM TRACK W/ HILTI X-DNI21 AND METAL STUD PARTITIONS DETAIL 34" MIN. TO 44" MAX. ON THE PULL/STRIKE SIDE OF THE EDGE W/ ANGLE f- I ..7r PS SHOT PINS 6 32" O.C. SEE 1/4" BEAD ACOUSTICAL SEALANT (E) CONC. FLOOR A.F.F. (TYP. FOR ALL DOOR MGR HHL Q HILTI FASTENERS * METAL STUD I� CONT. AT EACH SIDE. \ OPERABLE PARTS) PARTITIONS DETAIL ,, ! ,� 01-0" Zi/- -I - 8 EXIT DOORS SHALL COMPLY WITH JOB CEN014 I\ CAULK (E) CONC. SLAB FLOOR LEVER PUSH PULL 2016 CSC 1010 4115-404 PROJECTION SCREEN FULL HEIGHT WALL CCG. HIGH WALL NEW PONY WALL DOOR HARDWARE SHEET A-700 14 SCALE: 3" = 1 '-0"GI D-CLPRSC SCALE: 3" = 1'-0" D-WLDMS SCALE: 3" = 1 '-0" D-WLCH11 SCALE: 1-1/2" = 1'-0" D-WLPONY5A SCALE: 3/8" = 1 '-0" D.DR.HDWR 2016 OF SHEETS HDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NIDI TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIiSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT, 4—WAY / 05/REVISIONS BY t3" MAX: TIGHT WALL (RESTRAINED) m 4' ��������������������� a7 n SEISMIC ONE SIDE OF BIDSET/ PC" oC[I EXPANSION SPLICE CAP-�—� I I ° 1 1 JOINT CLIP CRIMPED TO ALLOW PERIMETER �� 1 „ � © Cros ee X 31C _ ` ' •.. ONLY ON HANGER 2�„ - / 1 'ob ' / OPPOSITE END ,.....„..„..,,VERTICAL _ 2' o.c. / r ` � Oq :::ERs '°�; ••�j � � ---. VERTICAL HANGER ��` REQUIRED ° '��.�*► ;� /7/// V"� \ Crosse ee 8" MAX. -'14 WIRE 12 GA ® AT ALL e ° e / :,, ,7„._.4.:: / ; R> o e r\! / TEE �� �f\>�iiiS .E.W. MAINBEAM e o �;►` C�- fir,- JOINTS O \�` � #3 `►�\�/ 1„ GAP �. �-MAIN TEE i . .,, �\ BETWEEN 0: 0' 0 0 / Ii !! E m00 � o4/co c N .. ZSEE o. r = ���� -411 / Wig1;�� rio ` rte- • �� I� NOTE: EXPANSION JOINT REQUIRED •>7,--- A' / w o 6 \ iioi000 COR LNG EH GH PARTITIONS)IONSSF )OR 9 0 • O ( +;. ;k �(,.; / m Warill • . '1, - -- MIN. INTERSECTION SEISMIC JT. CLIP SYSTEM MAIN BEAM SEISMIC JOINT 4—WAY SEISMIC SEPARATION JT. CLIP ` �` Q ' • J• > vv � ,� STRENGTH LIMITS: 180 LBS. P X Z �� >v z a o LAYOUT (BY ARMSTRONG) CLIP (By ARMSTRONG FOR CEILINGS OVER 2500 SF) (BY USG FOR CEILINGS OVER 2500 SF) RESTRAINED — BERC2 CLIP O ` O 1 AIR TERMINALS: / Z SEISMIC PERSPECTIVE (TIGHT WALL) / <20 LBS. - POSITIVELY ATTACHED TO GRID. 6 MAIN BEAMS & CROSS TEES MUST BE TIED RESTRAINED GRID ® WALL 20-56 LBS. - POSITIVELY ATTACHED TO TOGETHER W/ STABILIZER BARS TO PREVENT i THEM FROM SPREADING. •• SikED 49 _ -_ �� �____ ->,.! GRID AND TWO WIRES TO STRUCTURE (MAY •i C1 BE SLACK) 0 GRID SYSTEM: HEAVY-DUTY RATING. WARE ER ` © )( �( tHEiATIER H. LARSEN iX X �( ,� )( /( > 56 LBS. SUPPORTED DIRECTLY TO 80 CEILINGS OVER 1,000 SF MUST HAVE a� Q STRUCTURE PER DESIGN. HORIZONTAL RESTRAINT WIRES OR RIGID \ �' ' i \ • • 2 SPRINKLER HEAD AND OTHER PENETRATION BRACING. SEE COMPRESSION POST DETAIL. ll HANGER ���� iiiiii/ii� i�iiiii� - a S 0 E WIRE �� ROSE+AUE, CALIFORNIA W ARI-11468 - X O CLEARANCE: SHALL BE MIN. 2” DIA. OPENING g0 CEILINGS OVER 2,500 SF MUST HAVE /�� TEE-FACE $" MAX FLOATING WALL �.q, EXP.1231-18 `�� OR PROVIDE A SWING JOINT, FOR CEILINGS SEISMIC SEPARATION JOINTS OR FULL HT. ,--- SLEEVE r 4 )( 12-GAUGE VERTICAL HANGER WIRE OF ' I WITHOUT RIGID BRACING. PARTITIONS. SEE SEISMIC SEPARATION JOINT o o �1 �` /_ v\ /( /. iv-� ® X X " 30 CABLE TRAYS AND ELECTRICAL CONDUIT: CLIP DETAILS. ¢ /+,o�,I� T BERC2 SEISMIC CLIP, BY ARMSTONG 6' MAX. 12'-0" 6 �AX. e SHALL BE INDEPENDENTLY SUPPORTED AND / i� 10 CHANGES IN CEILING PLANE MUST HAVE ONE SIDE OF SPLICE •/ TEE-FACE / ` �I ` X� BRACED. O CAP CRIMPED TO ,/ °� SLEEVE iE _ T !ERC2MIcCUPBYARM STRONG LLJ POSITIVE (RIGID) BRACING. `Q OR RIVETED CONNECTION AT TEE TO ---• ALLOW MOVEMENT ONLY Z WALL MOLDING AT TIGHT WALLS) W -� 4 -0 4 WALL MOLDING: MIN. 2'. RIVITS ® O ON OPPOSITE END '< A�� / " �, y p J / / 11 SUSPENDED CEILINGS WILL BE SUBJECT TO < 1 / / RESTRAINED WALLS UNLESS USING >\ ` ^ PROPRIETARY CLIPS PER 2 & 3 THIS SHT. SPECIAL INSPECTIONS, AS DETERMINED BY 4 < ® �< >< SEISMIC RCP - PARTIAL a Z',:, i._ mil o I Q 0 GRID MUST BE ATTACHED OR RESTRAINED ON TEE FACE SLEEVE TEE FACE SLEEVE W i� 12 VERTICAL PERIMETER SUPPORT WIRES ARE TWO ADJACENT WALLS WITH POP RIVETS, O �_� '..- Cl' - X ® SCREWS OR OTHER MEANS - OPPOSITE REQUIRED, MAX 8" FROM WALL. (FOR DX, DXL, DXT BY USG) (FOR DXF, DXFF BY USG) , .0 Uj o 1 I p WALLS MUST HAVE §" CLEARANCE. Z N ADD'L GENERAL REQUIREMENTS 4 w Z EXISTING WOOD FRAMING ® ROOF/ -• 0 E 1111 V ix 1 ., FLOOR, FIELD VERIFY. UNRESTRAINED - BERC2 CLIP �� „ COMPRESSION STRUT TABLEMINIMUM 3"W x 4"L x 12 GA. STEEL NOTE: WALL BRACING SHALL BE (FLOATING WALL) I Lu ` STRAP: SECURE TO DECK W/ 2 NOMINAL AREA RADIUS WALL OUTSIDE INDEPENDENT OF CEILING SPLAY I !� _ # x2" WOOD SCREWS INTO JOISTS.> 12HEIGHT EMT DIA. (SO. IN.)(SQ, IN.) THK. (IN.) DIA. (IN.) BRACING bt x ® )( )( `� )( X UP TO 6' 1/2" .087 .235 .042 .706 WITH USE OF ALTERNATE I RUN IN DIRECTION OF WIRE. 9' 3/4" .134 .309 .049 .922 CONNECTOR CLIP TO STRUCTURE / ARMSTRONG SEISMIC RX 11' 1" .201 .391 .057 1.163 ABOVE. MIN. 100 LB. IN SUSPENSION SYSTEM PER ICC i / \/i I SPLAYED HANGER WIRE: FOUR TIGHT 14' 1-1/4" .295 .511 .065 1.51 WITHDRAWAL. TYP. ® ALL WIRE REPORT ESR-1308: io %" TURNS IN 1 X" CONNECTIONS - MAX. 1l COMPRESSION POSTS: ELEC. UNDERSIDE OF FLOOR OR ROOF 1. ALL STANDARD SEISMIC 3. BERC2 CLIPS AT TIGHT 5. ESR-1308: TESTING 1 * * i / CONDUIT (EXTEND TUBE TO STRUCT. APPLICATIONS PER DETAIL WALLS (RESTRAINED) & RESULTS DEMONSTRATE THE X *--_`_ * I i BE TIGHT TO CEIL'G GRID 1/THIS SHEET, SHALL APPLY FLOATING WALLS (CLEARANCE, FOLLOWING ARMSTRONG " NO. 12 GA. VERTICAL CEILING & GRID SYSTEMS CAN Z • AND STRUCT. ABOVE. THEN FOR ARMSTRONG PRODUCTS, UNRESTRAINED) APPLIED AT MPS INSTALL BOLT TO SECURE Fir WIRE HANGER IN EXCEPT AS NOTED BELOW_ WITHSTAND SEISMIC FORCES IN 0 PERIMETER TEE ENDS TIED UNRESTRAINED GRID ® WALL Z/ TURNING. LEVEL ALL RUNNERS. CATEGORIES D, E, & F FOR MAX. ONE TUBE TO THE OTHER). I C£IL'G GRID PRIOR HEAVY-DUTY CLASSIFICATION: Z TOGETHER WITH STABILIZER BARS - / / INSTALL 12' Q. .E.W. � ' 2. WALL ANGLE/ MOLDING - 4. BERC2 MAINTAINS MAIN y� Q TO SETTING TUBE. LOCATE . PRELUDE 1 46 EXPOSED TYP. ® 4 SIDES LEGEND VERTICAL HANGER WIRE: THREE STARTING 6' FR•• WALLS. ..->-- y r�' IN LIEU OF 2". GRID BEAM & CROSS TEE SPACING XL, � AT 4' O.C. EA. WAY MUST BE ATTACHED ON TWO - NO OTHER COMPONENTS TEE SYSTEM, STANDARD W X 12-GAUGE VERTICAL HANGER TIGHT TURNS IN 1 Y2" ` ADJACENT WALLS WITH BERC2 REQUIRED. DELETE STABILIZER FIREGUARD Sc ENVIRONMENTAL. WIRES0 VER12 TICAL 45 I 45' DRILL 5/32" HOLE (OR POP RIVETS IF APPROVED BARS AT PERIMETER. SILHOUETTE XL, Y4" REVEAL, SUSPENSION WIRES AT WOOD FRAMING .,..•„i & INSTALL 1/8" BY ARCHITECT). - OPPOSITE die" BOLT/ SLOT SYSTEM & Ye" RIGID BRACING (COMPRESSION MAIN TO I`1. BOLT & LOCKING WALLS (FLOATING) REQUIRE REVEAL, %6" BOLT/ SLOT W POSTS) RUNNER W/ U NUT BERC2 WITH %" CLEARANCE. SYSTEM. EXISTING WOOD ROOF FRAMING, 3 TURNS IN` ',� SEISMIC REFLECTED STABILIZER BARS FIELD VERIFY. 1 ,�" ® GENERAL REQUIREMENTS �' N CEILING PLAN GRIDPERIMETER RIVITED 4'-0" f EMT SLEEVE 8 I� MINIMUM 2" x 2" x " STEEL o.c.E.w., THIN WALL �rN 0) MAX. \� k.„ ANGLE, ATTACH TO WOOD JOISTS - - - -f� 1 ELEC. CON- ZJ f3UlT W SLOT LL I I _L_ ABOVE WITH 2 — #8 WOOD 45' / 1 — SCREWS END TO FIT 0 ALTERNATE SEISMIC APPLICATION - BY ARMSTRONG W A* o f-"\ t OVER CEIL'G SCALE NTS ` IX STRUT TIGHT TO ANGLE RUNNER. SEE STRUTS til < �, ' MAIN RUNNER SPAN TABLE FOR (� 9 GA WIRE OR 45' 4�- SIZES & MAX. F APPROVED LIGHT FIXTURE WEIGHTS: ATTACH COMPRESSION STRUT • 2'' {HEAVY DUTY HEIGHTS. FLANGE TO ANGLE3 ALTERNATE. ABOVE W/ MIN. --1-1--1-1-.' CLASSIFICATION) W SECURELY ATTACH <10 LBS. - ONE WIRE TO 'ti. 2"x 2"x 12 GA CLIP AND #8 x J1" CROSS RUNNER Y 0 TO STR. ABOVE STRUCTURE. O SELF TAPPING RHSMS. - W/ CONNECTOR COMPRESSION STRUT AT WOOD FRAMING WALL 4'-0" MAX. L CLIP. _.-400" 10-56 LBS. - 2 WIRES HORIZONTAL RESTRAINT: RIGID BRACING OR (4) #12 GA. SPLAY ` e�pp FROM HOUSING TO WIRES 90 DEC. APART. VERTICAL ANGLE = 45'. ALL WIRES TIGHT WALL (RESTRAINED) 0 LIGHT FIXTURE CROSS TEE STRUCTURE HANGER/ STRUT ATTACHMENTS SECURED TO RUNNERS WITHIN 2" FROM INTERSECTION. �a" CLR. ® /////17////////// /////////, ` MOUNTING CONNECTION STRENGTH 200 LBS. OR DESIGN LOAD, MIN. FLOATING (UNRESTRAINED) 1" - - - - " - " 0') BRACKET > 56 LBS. - SUPPORTED (® WOOD DECK) WHICHEVER IS GREATER. WALL — \ DIRECTLY TO STRUCTURE ATTACH Cross Tee x �V J COMPOSITE METAL DECK/ CONCRETE NOTES: 1. USE OF METAL STUD IN LIEU OF CONDUIT TUBING FOR STRUT WILL REQUIRE AN ONE SCREW PER DESIGN. ` N SECTION ATTACH SCREW ALTERNATE METHOD & MATERIAL W/ CITY APPROVAL. THROUGH O C� / 1 - ,Ipl lIiip 2. STRUTS OVER 12' MAY REQUIRE ENGINEERING CALCULATIONS. LONG & HEAVY EITHER I I /-\ EITHERTOP - 2' 0.0. / a b �� 3,�W x 4"L x 12" GA. STEEL STRAP: STRUTS PRESENT ADDITIONAL SEISMIC HAZARD. THEREFORE, THE APPLICANT MAY SIDE ( I FASTENER Q A SECURE TO DECK W/ "HILTI" " DIA. BE REQUIRED TO PROVIDE CALCULATIONS SHOWING THAT ADDITIONAL STRUT LOAD OPENING Cross Tee LIGHT FIXTURE �g KWIK BOLT II FASTENERS: RUN IN CAN BE SUPPORTED VERTICALLY AND LATERALLY BY THE SUSPENSION SYSTEM I I N� SUSPENDED DIRECTION OF WIRE. ELEMENTS SUCH AS MAIN RUNNERS, VERTICAL AND SPLAYED WIRED, ETC. �� Ci CEILING PANEL Q ACM7 --1___/ SPLAYED HANGER WIRE: FOUR 3. NOTE: USE OF METAL STUD IN LIEU OF CONDUIT TUBING FOR STRUT WILL ATTACHMENT REQUIRE AN ALTERNATE METHOD & MATERIAL W/ CITY APPROVAL. �` WALL CLIP 0 0 0 0 Z MAX. TIGHT TURNS IN 1 Y2" 4. MAINTAIN REQUIRED CLEARANCES TO UNBRACED PIPES AND DUCTS. 1- ~ I- i- O )1C co U B o• • C y o CD Zo - LIGHT FIXTURE ��� SEISMIC PERSPECTIVE COMPRESSION POSTS RESTRAINED-ACM7 CLIP - cE w O PENDANT HUNG M�aX M TIGHT WALL & FLOATING WALL %CS" :::' Q E-. W • VERTICAL HANGER WIRE: THREE WITH USE OF ALTERNATE USG / Q 9 GA. WIRE - MAY BE SLACK. TIGHT TURNS IN 1 Y2" j j SEISMIC J// 0 SECURELY ATTACH TO STR. ABOVE `� 9 GA. WIRE - / jar� W CONNECTOR CLIP. MAY BE SLACK. REPORT ESR 1222 / Z j � SUSPENSION SYSTEM PER ICC .:.:.: :::. :... ,:.:�f' V / SECURELY WIRES AT METAL DECK AND COMPOSITE DECK AND CONCRETE % PERIMETER Z V • ATTACH TO STR. O PERIMETER VERTICAL LIGHT FIXTURE (ALL TYPES) HANGER WIRES 1. ALL STANDARD SEISMIC 4. STABILIZER BARS ARE NOT / J RID ABOVE W/ VERTICAL APPLICATIONS PER DETAIL 1 THIS REQUIRED AT PERIMETER. MECHANICALLY ATTACHED TOG CONNECTOR HANGER WIRES / • � � — 410-16 2 PER FIXTURE SHEET SHALL APPLY FOR USG W • ., „ k.....„_\\\ MAX. POSITION (NEC CLIP. 8 MAX. 8 MAX. ` PRODUCTS EXCEPT AS NOTED 5. DELETE VERTICAL HANGER W UNLESS INDEPENDENTLY I MAX. POSITION '6 OUT OF PLUMB ' � U SUPPORTED. COMPOSITE METAL DECK/ OUT OF �� BELOW. WIRES 8" FROM WALL. _ / 1i (f� SU 1 j / CONCRETE SECTION PLUMB 1 / Q LIGHT FIXTURE �] `� t10' 6 j ±1O' 2. WALL ANGLE/ MOLDING 6. (ICC ES) AC156 & AC 368 / LIGHT FIXTURE / Q j • MOUNTING / MAX 12 GA. / MAX Q6 741" IN LIEU OF 2". GRID MUST TEST DATA DEMONSTRATES THAT / CC BRACKET _ 2 x 2 x ) STEEL ANGLE, / j THE FOLLOWING CEILING & GRID • 4 Cl) • 0 O 0 CROSS TEE ATTACH TO STEEL DECK ABOVE / VERTICAL 12 GA. VERTICAL BE ATTACHED ON TWO ADJACENT r.� la r� is „ HANGER WIRE / ll WALLS WITH ACM7 (OR POP SYSTEMS CAN WITHSTAND Q 11 thr WITHHILTI DIA. KWIKB0LTII HANGERWIRE ��/�T��//�/�/���T��������1 ISTABILIZER RIVETS IF APPROVED BY SEISMIC FORCES IN CATEGORIES Z Q y FASTENERS. % STABILIZER _ D, E, & F FOR THE FOLLOWING FLOATING WALL �LIGHT BAR ARCHITECT). PPOSITE WALLS BAR , FLOATING RE:NSU°ICA RE ACM7WITHUSG SUSPENSION SYSTEMS: X 12-GAUGEVERTICALHANGER QSEISMIC # iXTURE STRUT TIGHT TO ANGLE MiN. { } DXL-H (HEAVY DUTY) WIRE � W CLIP 3„ � � �3/4" �.i � -�a CLEARE ACM7 SEISMIC CLIPBY USGDXL-1 (INTERMEDIATEDUTY) T CA O #8XYa `�..„� - - �/ I3. ACM7CLIPT TIGHTWALLS" SHEET ATTACH COMPRESSION STRUT , or. • oACM7 SEISMIC I oar�/ METALFLANGE TO ANGLE ABOVE W/ « {RESTRAINED) FLOATING WALLS CLP BY USG {OR E 05/23/2018 ► - CLEARANCE, RIVETED CONNECTION AT TEE TO WALL SCREW 2 x 2 x 12 GA CLIP AND #8 / 2" ( UNRESTRAINED) ,,,r„ , IN. POP RIVET OR SCREW iN. 2' APPLIED AT ALL RUNNERS. MOLDING AT TIGHT WALLS) KALE SUSPENDED x Y2" SELF TAPPING RHSMS REQUIRED ON TWO ADJACENT AS NOTED CEILING PANELCOMPRESSION STRUT AT CONCRETE OVER METAL DECK WALLS. SEE SEISMIC RCP ( g ; PLAN. MGR HHL TLIGHT FIXTURE ATTACHMENT CAN LIGHT FIXTURE HANGER/ STRUT ATTACHMENTS RESTRAINED TEE UNRESTRAINED TEE GENERAL REQUIREMENTS SEISMIC RCP — PARTIAL JOB CEN014 (® CONCRETE OR COMPOSITE DECK) SHEET 0 STANDARD SEISMIC APPLICATIONS — IBC SEISMIC CATEGORY D BASIC CONNECTIONS, PERIMETER & LATERAL SPLAY BRACING. INSTALLATION MUST CONFORM TO CISCA RECOMMENDATIONS FOR AREAS SUBJECT TO SEVERE SEISMIC ACTIVITY. ALTERNATE SEISMIC APPLICATION — BY USGSCALE : NTS A-800 SCALE : NTS 0 • , , , OF SHEETS 1 HDL DESIGN HEREBYI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE N3T TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMI4SI0N OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I N REVISIONS BY MECHANICAL CRITERIA MECHANICAL CRITERIA (CONT.) MECHANICAL SYMBOL LIST o gcvTr 1. BEFORE SUBMITTING A PROPOSAL,THE MECHANICAL CONTRACTOR SHALL VISIT THE 14. FABRICATE AND INSTALL GALVANIZED SHEET METAL DUCTWORK FOR VELOCITIES LESSF-, Q M ® SITE OF WORK AND FAMILIARIZE HIMSELF WITH ALL SITE CONDITIONS. MECHANICAL THAN 2000 FEET PER MINUTE AND STATIC PRESSURES LESS THAN 2"WATER GAUGE IN SUPPLY AIR DUCT UP C o O n CONTRACTOR SHALL CAREFULLY EXAMINE ALL CIVIL,ARCHITECTURAL, STRUCTURAL, ACCORDANCE WITH THE LATEST EDITION OF THE"LOW VELOCITY DUCT CONSTRUCTION pe N L7 '^ PLUMBING, MECHANICAL AND ELECTRICAL CONSTRUCTION DOCUMENTS. SUBMISSION STANDARDS"AS PUBLISHED BY THE SMACNA. PROVIDE ELBOWS.BRANCHES AND TEES f' SUPPLY AIR DUCT DOWN Q ¢ oC Z OF A BID WILL ACKNOWLEDGE THE MECHANICAL CONTRACTOR HAS VISITED THE SITE IN SUPPLY AND RETURN DUCTS WITH TURNING VANES PER SMACNA STANDARDS. o Z ° oao AND EXAMINED ALL CONSTRUCTION DOCUMENTS AND BID INSTRUCTIONS.THE INSULATED FLEXIBLE DUCT SHALL BE"THERMAFLEX"TYPE MK-E. DUCT SIZES SHOWN RETURN AIR DUCT UP 0 H,. c n z Y MECHANICAL CONTRACTOR'S BID SHALL INCLUDE ALL MECHANICAL WORK IN THE ON THE DRAWINGS ARE SHEET METAL SIZE AND INCLUDE DUCT LINER AS SCHEDULED VI RETURN AIR DUCT DOWN U Z U 0 CONSTRUCTION DOCUMENTS, INCLUDING MECHANICAL WORK RELATED TO EQUIPMENT ON THE DRAWINGS. DUCTWORK WITHOUT AN INSULATION TAG IS NOT LINED OR yr H Z PROVIDED BY OTHERS. EXTERNALLY INSULATED.THE MECHANICAL CONTRACTOR SHALL PROTECT ALL DUCT 0 • VI EXHAUST AIR DUCT UP 2 SYSTEMS AND MECHANICAL EQUIPMENT OPENINGS FROM CONSTRUCTION DUST AND Z Lc Q O 0 2, MECHANICAL CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ITEM(S)OF THE DIRT. FOR MECHANICAL EQUIPMENT OPERATED DURING CONSTRUCTION, PROTECT ©y EXHAUST AIR DUCT DOWN p[ �, CONTRACT DOCUMENTS THAT ARE NOT UNDERSTOOD OR WHERE CONFLICTS MAY EACH RETURN AIR DUCT OPENING WITH MERV 8 FILTERS AND INSTALL MERV 8 u' CCd� Q Z EXIST.CLARIFICATIONS MUST BE PRESENTED AS A"REQUEST FOR INFORMATION"(RFI) FILTER(S) IN EQUIPMENT FILTER RACK. UPON COMPLETION OF CONSTRUCTION. �r _u O °C C,� 4 CHANGE IN DUCT SIZE QE IN WRITING PRIOR TO SUBMITTING A BID. RFI SHALL BE PRESENTED A MINIMUM OF FIVE REMOVE CONSTRUCTION FILTERS AND REPLACE EQUIPMENT FILTERS WITH NEW C� Z m • 0 (5)WORKING DAYS BEFORE THE BID DATE. OBTAIN THE RFI FORM AT FILTERS. .) - TURNING VANES �j Mr. ` u v WWWn H Q a o ACKNOWLEDGE THE MECHANICAL CONTRACTOR UNDERSTANDS THE SCOPE OF WORK. 15. ALL JOINTS AND SEAMS OF NEW DUCT AND DUCT BEING RE-USED SHALL BE CLEANED . FLEXIBLE DUCT CONNECTION L.C.] ¢ `_' d Q �J < ° co MEANS AND METHODS OF INSTALLATION, EQUIPMENT AND MATERIALS TO BE USED. RFI AND SEALED.SEAL NEW DUCTS TO THE FOLLOWING SEAL CLASSES ACCORDING TO Z I- 4°) U r` THAT HAVE NOT BEEN CLARIFIED PRIOR TO BID,WILL BE PROVIDED BY THE SMACNA"HVAC DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE": SEAL I IpRIZONTAL LIFE SAFETY DAMPER r°� ,7'; Z C 4 (0 CI MECHANICAL CONTRACTOR,AS DIRECTED BY THE ENGINEER OF RECORD,AND THE DUCTS WITH"FOSTER"32-14 SEALANT PER MANUFACTURES INSTALLATION V W - n n 11) MOST STRINGENT MATERIALS, EQUIPMENT,AND SCOPE OF WORK SHALL APPLY. NO INSTRUCTIONS FOR ALL JOINTS IN LOW AND MEDIUM VELOCITY DUCT. oe n n p 1~ VERTICAL LIFE SAFETY DAMPER ADDITIONAL COMPENSATION WILL BE MADE FOR THE FAILURE OF THE CONTRACTOR TO OUTDOOR, SUPPLY-AIR DUCTS: SEAL CLASS A. 0 2 t OBTAIN CLARIFICATIONS PRIOR TO BID. OUTDOOR, EXHAUST DUCTS. SEAL CLASS C. MMOTORIZED AUTOMATIC DAMPER(MAD) u Q,42 e OUTDOOR. RETURN-AIR DUCTS: SEAL CLASS C. MECHANICAL ABBREVIATIONS U 1 -`11- -- v 3. THE MECHANICAL CONTRACTOR'S BID SHALL BE BASED ON THE SCHEDULED UNCONDITIONED SPACE,SUPPLY-AIR DUCTS IN PRESSURE CLASS 2-INCH W.G.AND LMANUAL DAMPER - c X EQUIPMENT, MATERIALS,AND MANUFACTURERS WHICH FORM THE"BASIS OF DESIGN". LOWER:SEAL CLASS B. L d = a AFF ABOVE FINISHED FLOOR a u. ALL OTHER EQUIPMENT.MATERIALS,AND MANUFACTURERS,ARE CONSIDERED UNCONDITIONED SPACE,EXHAUST DUCTS: SEAL CLASS C. F CARBON DIOXIDE DETECTOR i SUBSTITUTIONS.CONTRACTOR PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO UNCONDITIONED SPACE,RETURN-AIR DUCTS: SEAL CLASS B. Oco= AHJ AUTHORITY HAVING JURISDICTION p 0 THE ENGINEER OF RECORD FOR REVIEW AND WITH A COMPLETED SUBSTITUTION CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASS 2-INCH W.G.AND AHU AIR HANDLING UNIE Q .8 QQ CARBON MONOXIDE DETECTOR A.I.P. ABANDON IN PLACE � REQUEST FORM. OBTAIN THIS FORM AT WWW.GANDWENGINEERING.COMID000MENTS. LOWER;SEAL CLASS C. co r ..c AL ALUMINUM iigi�f APPROVALS OF SUBSTITUTIONS ARE CONTINGENT UPON ENGINEER'S REVIEW.THE CONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS B. H HUMIDISTAT v u O ALT ALTERNATE Q� \NES 0 MECHANICAL CONTRACTOR SHALL MAKE NO PRIOR ASSUMPTIONS ON SUBSTITUTIONS CONDITIONED SPACE, RETURN AIR DUCTS:SEAL CLASS C. K G A 'L NOT APPROVED BY THE ENGINEER. IF THE ENGINEER APPROVES A SUBSTITUTION nn MANOMETER AP ACCESS PANEL ,,� 97, REQUEST.THE MECHANICAL CONTRACTOR WILL BE HELD RESPONSIBLE FOR 16. TEST AND ADJUST ALL AIR HANDLING EQUIPMENT,TERMINALS,AND AIR DEVICES TO AS AIR SEPARATOR 533pt. ATC AUTOMATIC TEMPERATURE CONTROL VALVE 79 ENGINEERING REVISIONS, PHYSICAL SIZE,CAPACITIES,COORDINATION, PROVIDE THE REQUIRED AIR VOLUME AGAINST THE AVAILABLE SYSTEM STATIC 0 PRESSURE SWITCH ATR ALL THREAD ROD F SUPPLEMENTAL DRAWINGS AND INFORMING OTHER TRADE CONTRACTORS RELATED PRESSURE. TEST AND SET ALL DAMPERS, SUPPLY, RETURN,OUTDOOR AIR AND ATU AIR TERMINAL UNIT TO THE INSTALLATION,AS TO ANY SPECIFIED ITEM CHANGES.THE MECHANICAL EXHAUST DEVICES TO THE CFM SHOWN ON THE DRAWINGS. PROVIDE ALL REQUIRED RETURN AIR SMOKE DETECTOR Cr o-'�" AV MANUAL AIR VENT 1 CONTRACTOR SHALL BEAR AS PART OF HIS CONTRACT,ANY ADDITIONAL COSTS SHEAVE AND BELT MODIFICATIONS REQUIRED TO OBTAIN CFM QUANTITIES SHOWN ON p' G w BB BASEBOARD HEATER O INCURRED IN HIS WORK OR BY THE OTHER CONTRACTORS AS A RESULT OF THE DRAWINGS. TESTING AND BALANCING SHALL BE IN ACCORDANCE WITH F REFRIGERANT(Rxxx)DETECTORM :., �G. O BDD BACK DRAFT DAMPER ,I!': INSTALLATION FOR OTHER THAN"BASIS OF DESIGN"MATERIALS AND EQUIPMENT. PROCEDURES OUTLINED IN TESTING AND BALANCING MANUAL AS PUBLISHED BY REF BES BANKING EQUIPMENT SUPPLIER1-1% ' SMACNA. PROVIDE A TEST AND BALANCE REPORT PERFORMED AND PREPARED BY AN ®Q REFRIGERANT LEAK HORN-STROBE BFF BELOW FINISHED FLOOR 4 A 4. MECHANICAL CONTRACTOR SHALL PERFORM WORK IN A SAFE MANNER.COMPLY WITH INDEPENDENT TESTING AND BALANCING CONTRACTOR CERTIFIED AABC OR NEBB. BMS BUILDING MANAGEMENT SYSTEM APPLICABLE OSHA SAFETY GUIDELINES DURING THE COURSE OF COMPLETING THE PROVIDE AN ELECTRONIC COPY OF THE TESTING AND BLANACING REPORT, INCLUDING 0 THERMOSTAT BOD BOTTOM OF DUCT 118 WORK DESCRIBED ON THESE CONSTRUCTION DOCUMENTS. A MARKED UP PLAN, FOR REVIEW BY THE ENGINEER.TESTING AND BALANCING REPORT BOE BOTTOM OF EQUIPMENT SHALL BE COMPLETED AND PROVIDED TO THE ENGINEER PRIOR TO TENANT MOVE IN. PIPE/DUCT IN ATTIC BOP BOTTOM OF PIPE 5. SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY AS PDF FILES. SHOP BS BRANCH SELECTOR-DAIKIN W DRAWINGS SHALL INCLUDE TRANSMITTAL PAGE(S)INDICATING THE NAME OF THE 17. MECHANICAL CONTRACTOR SHALL PROVIDE TEMPERATURE CONTROL WIRING THIS D PIPE/DUCT BELOW FLOOR OR GRADE CH CHILLER n PROJECT,AND THE NAME,ADDRESS,AND PHONE NUMBER OF THE GENERAL AND WORK, NO EXCEPTIONS OR EXCLUSIONS. ALL SYSTEMS SHALL BE COMPLETECLG CEILING C MECHANICAL CONTRACTORS. GENERAL CONTRACTOR AND MECHANICAL INCLUDING, BUT NOT LIMITED TO; EXPERTISE, DESIGN, EQUIPMENT, CABINETS, BOXES, D PIPE/DUCT ABOVE CEILING CO CARBON MONOXIDEtz, 0 0 CONTRACTOR SHALL REVIEW SHOP DRAWING SUBMITTALS FOR COMPLIANCE, RELAYS, SWITCHES,CONTACTORS,TRANSFORMERS,CURRENT TRANSFORMERS, CO2 CARBON DIOXIDE Illik CONTENT AND COMPLETENESS AND PROVIDE A STAMP WITH THE DATE OF REVIEW AND WATER METERS AND ELECTRICAL ACCESSORIES. THE EXPANSION OF THE EXISTING ED EXPOSED DUCT,W/MILL PHOSPHATIZED FINISH CR CONDENSER WATER RETURN Q SIGNATURE OF THE REVIEWER. TRANSMITTAL PAGE SHALL HAVE INDEX WITH BAS INTO THIS TENANT FINISH SHALL INCLUDE ALL REQUIRED COMPONENTS TOZ CRAG COMPUTER ROOM AIR CONDITIONER Q SPECIFICATION SECTION AND DESCRIPTION OF SUBMITTED ITEMS. NO EXCEPTIONS MONITOR AND CONTROL THE NEW HVAC EQUIPMENT AND METER WATER AND I.T. PIPE/DUCT ON ROOF CRCU COMPUTER ROOM CONDENSING UNIT WILL BE TAKEN.SHOP DRAWINGS NOT SUBMITTED IN THIS FORMAT WILL BE REJECTED ELECTRICAL USE AS REQUIRED BY PROPERTY MANAGER. WIRING EXPOSED IN RETURN CS CONDENSER WATER SUPPLY AND WILL NOT CAUSE REASON FOR PROJECT DELAYS. EQUIPMENT SHALL NOT BE AIR PLENUM SHALL BE PLENUM RATED CABLE. PROVIDE SHOP DRAWINGS FOR REVIEW & NEW CONNECTION TO EXISTING(VERIFY SIZE CSST CORRUGATED STAINLESS STEEL TUBING 0 ORDERED UNTIL ENGINEER OF RECORD HAS PROCESSED APPLICABLE SHOP AND PROCESSING.THE SHOP DRAWINGS SHALL CONTAIN A CONTROL SEQUENCE AND LOCATION IN FIELD PRIOR TO BID) CT COOLING TOWER DRAWINGS.A MINIMUM OF SEVEN WORKING DAYS WILL BE ALLOWED FOR SUBMITTAL STATEMENT AND WIRING DIAGRAM WITH ALL PARTS INDICATED OR A BILL OF MATERIAL. NEW BRANCH DUCT TAP&CONNECTION CU CONDENSING UNIT PROCESSING BY THE ENGINEER. SUBMITTALS SHALL INCLUDE BUT NOT BE LIMITED TO: ALL CONTROLS SHALL BE SUPPLIED IN ACCORDANCE WITH THE BUILDING STANDARDS. �N TO EXISTING CUH CABINET UNIT HEATER J ALL NEW SCHEDULED EQUIPMENT AND ACCESSORIES, REGISTERS AND DIFFUSERS, ALL NEW EQUIPMENT AND PROGRAMMING SHALL COMPLY WITH BUILDING STANDARD DDC DIRECT DIGITAL CONTROL III AND TEST AND BALANCE REPORT. MONITOR AND CONTROL POINTS. ALL COSTS ASSOCIATED WITH HARDWARE. ® DUCT INSULATION(SEE SCHEDULE) DIFF DIFFUSER U t6 SOFTWARE AND TIME TO FULLY INTEGRATE THIS NEW EQUIPMENT INTO THE BUILDING ID x PLAN NOTE SYMBOL DISC DISCONNECT . 0 6. SUBMIT AND PAY FOR ALL REQUIRED WORK PERMITS. PROVIDE ALL REQUIRED STANDARD BAS SHALL BE INCLUDED IN THIS BID. ID ®0 DLSS DUCTLESS SPLIT SYSTEM INSPECTIONS AND RE-INSPECTIONS. PROVIDE A SIGNED CERTIFICATE OF INSPECTION Qx REVISION SYMBOL DN DOWN AT THE PROJECT COMPLETION. 18. THE LANDLORDS CONSTRUCTION CRITERIA, LEASE AGREEMENT,AND CONSTRUCTION DPS DIFFERENTIAL PRESSURE SWITCH STANDARDS ARE HERE-IN MADE PART OF THIS CONTRACT.ALL REQUIREMENTS IN THE EQUIPMENT CALLOUT(SEE SCHEDULE) (E) EXISTING 7. ALL EQUIPMENT AND MATERIALS SHALL BE SPECIFICALLY PROVIDED PER WRITTEN LANDLORDS CONSTRUCTION CRITERIA. LEASE AGREEMENT,AND CONSTRUCTION EA EXHAUST AIR INSTALLATION INSTRUCTIONS AS PUBLISHED BY THE MANUFACTURER OF THE STANDARDS REFERRED TO AS TENANT WORK IS DEFINED AS DIVISION 15 MECHANICAL © GRILLE/DIFFUSER CALLOUT(SEE SCHEDULE) EBB ELECTRIC BASE BOARD EQUIPMENT OR MATERIAL PROVIDER. MEANS AND METHODS OF INSTALLATION ARE TO WORK AND IS TO BE PROVIDED BY THE CONTRACTOR. IT IS THE RESPONSIBILITY OF ® EC ELECTRICAL WORK CONTRACTOR BE PROVIDED BY THE MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL THE MECHANICAL CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS AND CD LIFE SAFETY DAMPER CALLOUT(SEE SCHEDULE) EF EXHAUST FAN UNDERSTAND THE PRODUCT, MEANS AND METHODS OF INSTALLATION,THE COMPLETELY FAMILIARIZE HIMSELF WITH THESE DOCUMENTS PRIOR TO BIDDING THIS EG EXHAUST GRILLE MECHANICAL CONTRACTOR SHALL OBTAIN THE INSTALLATION INSTRUCTIONS AND PROJECT.SUBMISSION OF A BID ACKNOWLEDGES THE MECHANICAL CONTRACTOR HAS EXISTING DUCT TO REMAIN EMS ENERGY MANAGEMENT SYSTEM REQUIREMENTS PRIOR TO BID,ALL RFI AND CLARIFICATIONS OF SCOPE DURING COMPLIED WITH THIS REQUIREMENT OF THE CONTRACT, EQPT EQUIPMENT CONSTRUCTION WHERE THE CONTRACTOR HAS NOT PREVIOUSLY OBTAINED THIS - - - - EXISTING TO BE DEMOLISHED ER EXHAUST REGISTER INFORMATION FOR BIDDING PURPOSES WILL NOT BE CAUSE FOR ADDITIONAL COSTS 19. THE MECHANICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL INDICATED ERV ENERGY RECOVERY VENTILATOR MECHANICAL PIPING OR CONSTRUCTION DELAY. EXISTING MECHANICAL EQUIPMENT OCCURRING IN DEMOLISHED WALLS, FLOORS, ET EXPANSION TANK ATTICS AND CEILING AREAS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE EUH ELECTRIC UNIT HEATER 8. THE MECHANICAL SCOPE OF WORK SHALL BE PROVIDED TO COMPLY WITH THE 2014 GENERAL SCOPE OF DEMOLITION. DISCONNECT AND REMOVE MECHANICAL —A COMPRESSED AIR LINE EWC ELECTRIC WATER COOLER OREGON MECHANICAL SPECIALTY CODE, LOCAL ORDINANCES, STATE LAW,AND EQUIPMENT, DUCTS,AIR DEVICES,AND PIPING OCCURRING IN THESE AREAS. EWH ELECTRIC WATER HEATER FEDERAL LAW. REFER TO THE ARCHITECTURAL CODE BLOCK OR THE MUNICIPALITY MECHANICAL COMPONENTS INCLUDING MOTORS,TEMPERATURE CONTROL DEVICES. —CD— CONDENSATE DRAIN EXH EXHAUST WEBSITE FOR THE APPLICABLE CODES AND ADOPTED ORDINANCES PRIOR TO BID. GRILLES, DIFFUSERS,AIR TERMINALS, HANGERS, MOUNTING HARDWARE, ETC., MUST BE --CD--- CONDENSATE DRAIN BELOW FLOOR OR GRADE FA FIRE ALARM SUBMISSION OF A BID ACKNOWLEDGES THE MECHANICAL CONTRACTOR HAS REMOVED FROM THE PREMISES,TO BE LEGALLY DISPOSED OF 8Y THE MECHANICAL --CR--- CONDENSER WATER RETURN FAAP FIRE ALARM ANNUNCIATOR PANEL PERFORMED THIS REQUIREMENT AND THE BID INCLUDES LABOR AND MATERIAL TO CONTRACTOR.ALL LOOSE ENDS OF SYSTEMS WHERE SUCH ABANDONMENT HAS FACP FIRE ALARM CONTROL PANEL PROVIDE CODE COMPLIANCE. SEISMIC RESTRAINTS AND ANCHORAGE SHALL BE TERMINATED SHALL BE TRIMMED CLEAR AND APPROPRIATELY CAPPED OR SEALED IN A —CS CONDENSER WATER SUPPLY FC FLEX CONNECTION PROVIDED TO COMPLY WITH THE 2014 OREGON BUILDING SPECIALTY CODE. SAFE AND SECURE MANNER BEHIND NEW FINISHES. MAINTAIN SYSTEM CONTINUITY TO --CHR-- CHILLED&HOT WATER RETURN FCU FAN COIL UNIT ADJOINING AREAS AS NEEDED,THIS INCLUDES BUT IS NOT LIMITED TO REMOVAL, FD FIRE DAMPER 9. MECHANICAL CONTRACTOR SHALL PROVIDE FIELD COORDINATION WITH OTHER MODIFICATION AND REINSTALLATION OF EQUIPMENT AS NEEDED TO SUSTAIN THE —CHS— CHILLED&HOT WATER SUPPLY FPC FIRE PROTECTION CONTRACTOR TRADES;SYSTEMS AS SHOWN ARE DIAGRAMMATIC AND GIVE THE GENERAL EXISTING WORKING CONDITION OF ALL MECHANICAL EQUIPMENT AND TO RETURNFRT FIRE-RETARDANT-TREATED e 0 ---GWR-- CHILLED WATER RETURN 5 ARRANGEMENT AND LOCATIONS ONLY. MECHANICAL CONTRACTOR SHALL THESE AREAS TO FULL WORKING ORDER AT PROJECT COMPLETION. FSC FOOD SERVICE CONSULTANT 1111 Ti - COMPLETELY REVIEW ARCHITECTURAL DRAWINGS,STRUCTURAL DRAWINGS, CEILING —CWS -- CHILLED WATER SUPPLY FSD FIRE/SMOKE DAMPER N ELEVATIONS,AND SYSTEM DRAWINGS OF OTHER TRADES FOR DETAILS OF 20. THE MECHANICAL CONTRACTOR SHALL CONFINE HIS ACTIVITIES TO THE AREA SET D DRAIN LINE FSEC FOOD SERVICE EQPT. CONTRACTOR Z CONSTRUCTION. ROUGH-IN OF MECHANICAL DEVICES,AIR TERMINALS,EQUIPMENT, ASIDE FOR HIM TO DO HIS WORK AND SHALL NOT INTERFERE WITH ANY OF THE OWNER FTU FAN TERMINAL UNIT PIPING,ATTACHMENTS,AND HANGERS SHALL BE BASED ON THIS REVIEW. EXACT OR TENANT ACTIVITIES. THE MECHANICAL CONTRACTOR WILL NOT BE PERMITTED TO G GAS LINE FV FIELD VERIFY W LOCATIONS AND FINAL LAYOUT SHALL BE DETERMINED IN THE FIELD,PROVIDE ALL STORE MATERIAL EXCEPT WITHIN THE AREAS AS DIRECTED BY THE G.C. SHOULD ANY HG HOT GAS LINE GC GENERAL WORK CONTRACTOR . ,e 6 NECESSARY EQUIPMENT, DUCT TRANSITIONS, FITTINGS, HANGERS, SUPPORTS,AND DISTURBANCE OF EXISTING INSTALLATION BE NECESSARY,THE CONTRACTOR SHALL GF GAS FURNACE --HPWRHEAT PUMP WATER RETURN OFFSETS REQUIRED FOR A COMPLETE INSTALLATION IN ALL RESPECTS.THE SO INFORM THE OWNER OR TENANT WELL IN ADVANCE OF THE TIME CONTEMPLATED GWH GAS WATER HEATER MECHANICAL CONTRACTOR MEANS AND METHODS OF INSTALLATION SHALL PROVIDE FOR THE DISTURBANCE.AFTER A PLAN ACCEPTABLE TO THE OWNER OR TENANT HAS —HPWS— HEAT PUMP WATER SUPPLY HP HEAT PUMP FOR OPERATING EFFICIENCY, NEATNESS OF APPEARANCE,AND EASE OF BEEN FORMULATED,THE G.C. SHALL KEEP IN CLOSE PERSONAL CONTACT WITH THE --HPC-- HIGH PRESSURE CONDENSATE HP HORSEPOWER MAINTENANCE. THE MECHANICAL CONTRACTOR WILL PREPARE DIMENSIONED FIELD WORK TO SEE THAT IT IS EXECUTED IN ACCORDANCE WITH THE AGREED PROCEDURE. HRCU HEAT RECOVERY CONDENSING UNITla ERECTION DRAWINGS WHERE REQUIRED FOR USE BY THE INSTALLERS,TO INSURE --HWRHOT WATER RETURN HWCP HOT WATER CIRC. PUMP 3 F PROPER INSTALLATION AND COORDINATION THE MECHANICAL CONTRACTOR SHALL 21. CONTINUITY OF ALL BUILDING SERVICES AND UTILITIES SERVING FACILITIES IN THE —HPS— HIGH PRESSURE STEAM HX HEAT EXCHANGER0 TAKE THEIR OWN MEASUREMENTS AT THE BUILDING,AND BE RESPONSIBLE FOR THE BUILDING SHALL BE MAINTAINED WITHOUT INTERRUPTION, EXCEPT FOR SUCH A PERIOD IAH INTAKE AIR HOOD CORRECT LAYOUT. INTERPRETATION,AND USE OF ALL SIZES AND DIMENSIONS.THE OF TIME DESIGNATED BY THE G.C.THE MECHANICAL CONTRACTOR SHALL SO —HWS— HOT WATER SUPPLY IOM INSTALLATION&OPERATION MANUAL CONTRACTOR SHALL KEEP"AS-BUILT"INFORMATION DURING CONSTRUCTION AND ARRANGE AND EXECUTE HIS WORK THAT ANY CONNECTIONS. EITHER TEMPORARY OR --LPS LOW PRESSURE STEAM ID INSIDE DIAMETER EL FURNISH TO THE OWNER OR TENANT A RECORD SET OF LEGIBLE BLACK LINE PRINTS PERMANENT,OR REARRANGEMENT OF PRESENT EQUIPMENT, DUCTWORK AND PIPING IR INFRA-RED TUBE HEATER(GAS) AND AN ELECTRONIC COPY OF THESE DOCUMENTS AT THE PROJECT COMPLETION. SHALL BE IN SUCH A MANNER AS TO ASSURE FULL RESUMPTION OF SERVICE AT THE --MPC- MEDIUM PRESSURE CONDENSATE IV INTAKE VENTILATOR TIME DESIGNATED BY THE G.C. PROVIDE TEMPORARY CROSS CONNECTIONS, DUCTS, —MPS— MEDIUM PRESSURE STEAM KEF KITCHEN EXHAUST FAN 10. REVIEW ARCHITECTURAL DRAWINGS AND EXISTING SITE CONDITIONS FOR ALL FIRE PIPING. HANGERS AND VALVES NECESSARY TO ASSURE THIS CONTINUITY OF THE LLSV LIQUID LINE SOLENOID VALVE 11LL RATINGS AND FIRE RATED ASSEMBLIES PRIOR TO BIDDING THE PROJECT. PROVIDE FIRE BUILDING MECHANICAL SYSTEM AT NO ADDITIONAL COST TO THE OWNER OR TENANT. —MUW— MAKE-UP WATER LV LOUVER STOP AT EACH RATED WALL,FLOOR, CEILING-ROOF ASSEMBLY PENETRATION. FIRE MAINTAIN IS DEFINED TO INCLUDE. BUT IS NOT LIMITED TO, REMOVAL. MODIFICATION RL REFRIGERANT LIQUID LINE LPG LIQUIFIED PETROLEUM GAS(PROPANE) STOP SYSTEMS SHALL BE MANUFACTURED BY"3M". PROVIDE IN STRICT COMPLIANCE AND REINSTALLATION OF EQUIPMENT AND PIPING AS NEEDED TO SUSTAIN THE RS— REFRIGERANT SUCTION LINE MAX MAXIMUM mmm WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. PROVIDE EXISTING WORKING CONDITION OF THE MECHANICAL SYSTEM.THE MECHANICAL MC MECHANICAL WORK CONTRACTOR TAGGED CERTIFICATIONS AT EACH PENETRATION. PROVIDE SHOP DRAWINGS FOR CONTRACTOR SHALL RETURN THESE SYSTEMS OR AREAS TO FULL WORKING ORDER ' -TYPE EXISTING PIPE TO BE REMOVED MCA MINIMUM CIRCUIT AMPERES REVIEW WITH THE U.L. LISTING AND TEST CRITERIA PROVIDE FIRE STOPPING WHERE AT PROJECT COMPLETION. //l"I/ EXISTING PIPE TO BE REMOVED MCC MOTOR CONTROL CENTER I REQUIRED BY THE AUTHORITY HAVING JURISDICTION. EQUAL SYSTEMS AS MD MANUAL DAMPER MANUFACTURED BY"SPEC SEAL"OR"HILTI"WILL BE ACCEPTABLE. -TYPE(E)- EXISTING PIPING MIN MINIMUM MH MOUNTING HEIGHT 11. PROVIDE DUCT, PIPING,AND HANGER PENETRATIONS OF NON-RATED ASSEMBLIES MECHANICAL PIPING SYMBOLS MOCP MAXIMUM OVER CURRENT PROTECTION WITH DRAFT STOPPING.OR SMOKE BARRIER SEALANT SYSTEMS.THROUGH MTD MOUNTED PENETRATION SEALANT SYSTEMS SHALL BE MANUFACTURED BY"3M".APPLY IN STRICT ❑ AUTOMATIC AIR VENT(AAV) MUA MAKE-UP AIR COMPLIANCE WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. Ij AUTOMATIC FLOW CONTROL VALVE MUW MAKE UP WATER PROVIDE DRAFT STOPPING OR SMOKE BARRIER SEALANTS TO MEET APPROVAL OF THE NC NORMALLY CLOSED AUTHORITY HAVING JURISDICTION_ EQUAL SYSTEMS AS MANUFACTURED BY"SPEC q AUTOMATIC TEMPERATURE CONTROL NIC NOT IN CONTRACT SEAL"OR"HILTI"WILL BE ACCEPTABLE. GENERAL NOTES: MECHANICAL VALVE (3-WAY) NO NORMALLY OPEN ❑ AUTOMATIC TEMPERATURE CONTROL OA OUTDOOR AIR 12, THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL LABOR, EQUIPMENT AND A. CONTRACTOR SHALL CAREFULLY COORDINATE ANY FLOOR PENETRATIONS WITH D�4 VALVE (2 WAY) OD OUTSIDE DIAMETER MATERIAL INSTALLED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A GENERAL CONTRACTOR,TENANTS CONSTRUCTION COORDINATOR, BUILDING OWNERS 6 BALL VALVE(BV) OX OXYGEN PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE AND SHALL REPAIR OR REPRESENTATIVE AND TENANT BELOW. POST TENSIONED FLOOR SLAB CONSTRUCTION _ PC PLUMBING WORK CONTRACTOR LIJ REPLACE WITHOUT COST TO THE OWNER ANY EQUIPMENT WHICH IS DEFECTIVE OR SHALL BE X-RAYED AND ALL STRUCTURAL SYSTEMS PERMANENTLY MARKED ON THE F- CHECK VALVE(CV) PCF POUNDS/CUBIC FOOT IMPROPERLY INSTALLED. IN ADDITION,THIS CONTRACTOR SHALL ASSUME FULL FLOOR STRUCTURE AND IDENTIFIED PRIOR TO ANY PENETRATION BEING PERFORMED. 0 CIRCUIT SETTER(CS) PSG PUMP SUCTION GUIDECO RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS OR OTHER PT PRESSURE TREATED EQUIPMENT CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR B. LONG LEAD TIME ITEMS THAT MAY IMPACT THE PROJECT SCHEDULE MUST BE A COMPRESSED AIR QUICK-CONNECT PVC POLYVINYL CHLORIDE W MATERIALS INSTALLED UNDER THIS SECTION OF THE WORK. IDENTIFIED ALONG WITH THE SCHEDULE IMPACT AT TIME OF BID. FAILURE TO RA RETURN AIR COMMUNICATE LEAD TIME ISSUES WILL RESULT IN THE CONTRACTOR,AT HIS EXPENSE, D CONCENTRIC PIPE REDUCER RAH RELIEF AIR HOOD I- 13. MECHANICAL CONTRACTOR SHALL CUT AND PATCH(OR PATCH AFTER DEMOLITION) PROVIDING TEMPORARY FIXTURES OR EQUIPMENT TO ALLOW FOR SCHEDULED TENANT b ECCENTRIC PIPE REDUCER RF RETURN FAN ROOF,FLOORS,WALLS,AND CEILINGS WHERE REQUIRED TO INSTALL NEW OCCUPANCY_ THE TENANT/DESIGN TEAM WILL CONSIDER ALTERNATE PRODUCT RG RETURN GRILLE P MECHANICAL EQUIPMENT, DUCT,AND/OR PIPING SYSTEMS AND/OR DEMOLITION OF SUGGESTIONS BY THE CONTRACTOR(IF SUBMITTED PRIOR TO BID)TO MAINTAIN THE Iii RL EXISTING DEVICE RELOCATED EMERGENCY GAS SHUT-OFF VALVE RR RETURN REGISTER J SUCH. SURFACES SHALL BE PATCHED AND LEFT READY FOR FINAL SCHEDULED FINISH. SCHEDULE. RTD RESISTANCE TEMPERATURE DETECTOR ROOFING REPAIRS SHALL BE PERFORMED BY A QUALIFIED ROOFING CONTRACTOR L/'1 FLEXIBLE PIPE CONNECTION RTU ROOF TOP UNIT Q THAT MAINTAINS THE ROOF WARRANTY AT THE MECHANICAL CONTRACTOR'S EXPENSE. C. CONTRACTOR SHALL PROVIDE TEMPORARY/PORTABLE EQUIPMENT FOR COOLING ALL ROOFING WORK SHALL BE INCLUDED IN THE MECHANICAL CONTRACTOR'S BID. AND/OR HUMIDITY CONTROL IF REQUIRED FOR CONSTRUCTION AND APPLICATION OF ❑ GAS SHUT-OFF VALVE(SOV) RV RELIEF VENTILATOR 0 FINISHES. oa GATE VALVE(GT.V.) SA SUPPLY AIR SD SPLITTER DAMPER Z -1 11- GEAR OPERATED BUTTERFLY VALVE SF SUPPLY FAN Q SG SUPPLY GRILLE DTi GLOBE VALVE(GL.V.) SMS SHEET METAL SCREW I SS STAINLESS STEEL V HOSE END VALVE SSF SIDE STREAM FILTER 1 1 1 TA TRANSFER AIR ■C, • LP MANUAL,AIR VENT(MAV) TEMP TEMPORARY C 4 PETE'S PLUG TOD TOP OF DUCT (TEMPERATURE&PRESSURE PORT) TOP TOP OF PIPE vl PLUG VALVE TXV THERMAL EXPANSION VALVE TYP TYPICAL DATE Q PRESSURE GAUGE UH UNIT HEATER 05/23/2018 UON UNLESS OTHERWISE NOTED ce PRESSURE REDUCING VALVE(PRV) UNV UNIVERSAL SCALE AS NOTED STRAINER(BTR) UTR UP THROUGH ROOF VAV VARIABLE AIR VOLUME MGR JRA STRAINER WITH BLOWDOWN VFD VARIABLE FREQUENCY DRIVE VRF VARIABLE REFRIGERANT FLOW JOB THERMOMETER VRV VARIABLE REFRIGERANT VOLUME CENO�4 VSD VARIABLE SPEED DRIVE SHEET W/ WITH Fa TRIPLE DUTY VALVE(TDV) WP WEATHERPROOF CQ VALVE IN RISER WSHP WATER SOURCE HEAT PUMP \ _10 CD WATER METER XFMR TRANSFORMER OF SHEETS ' HDL DESIGN HEREBY EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, THESE PLANS AND DRAWINGS ARE IST TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERM1SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I r REVISIONS BY � g a Z C? p MAIN DUCT WITH 1" 3 PCF DENSITY LINER GRILLE, REGISTER, AND DIFFUSER SCHEDULE •TITUS o o� o n 1" 3 PCF DENSITY LINER SPIN IN WITH MANUAL VOLUME DAMPER < w o U MAX N PLAN MODEL NO. NECK SIZE FACE SIZE P.D. BORDER PATTERN FINISH NOTES SPIN IN WITH DAMPER MARK CFM C < D ,2 Z r INSULATED FLEXIBLE DUCT (8' MAX. LENGTH) EX-5 EXISTING SUPPLY DIFFUSER; BALANCE TO INDICATED CFM 1,3 ¢• `r INSULATED FLEXIBLE DUCT(8' MAX. LENGTH) O z J SA PAS 60 24"x24" 110 0.1 TYPE 3 4-WAY #26 1,2,3 D Z U 0 90 ADJUSTABLE ELBOW PULL FLEX \ U INSULATION OVER ELBOW TO GRILLE \ , ' SB PAS 80 24"x24" 235 0.1 TYPE 3 4-WAY #26 1,2,3 • u w � CONNECTION, SEAL WITH TIE WRAP. \ \ PULL FLEX INSULATION OVER SC PAS 100 24"x24" 400 0.1 TYPE 3 4-WAY #26 1,2,3 Z tg ¢ 0 Z CONNECT WITH SHEET METAL SCREWS 4 �1 MAIN DUCT COLLARS SEAL WITH TIE WRAP. p SD TBDI-80 100 48"x(2) 1" SLOTS 300 0.1 TYPE 3 2-WAY #26 2,4 C4 Pe U Z 0 LOCATIONS AT COLLAR. \ CONNECT WITH SHEET METAL SCREWS 4 LOCATIONS AT \ w p U Q Z ¢ C III E STANDARD CEILING COLLAR. ..r... EX-R EXISTING RETURN GRILLE 1,3 C3 U z r m i r- 0 GRID SUPPORT PATTERN �' I I Z U CO O a 6 0 DIFFUSER PLENUM FULL SIZE w z "' Q N Q co co v SECURE DIFFUSER TO CEILING NOTES: 1. SECURE GRILLE/DIFFUSER TO CEILING GRID WITH A MINIMUM OF (4)#10 TECH SCREWS. Z (f) }- lJ h OF DIFFUSER NECK, INSULATE co �" Z La o GRID WITH A MINIMUM OF (4) WITH 112"-2# DENSITY LINER 2. MECHANICAL CONTRACTOR TO VERIFY CEILING CONSTRUCTION WITH ARCHITECT AND EXISTING CONDITIONS AND ENSURE THAT ❑ M M0 I #10 TEK SCREWS. 777117,\�ti 1, IT IS COMPATIBLE WITH GRILLE, REGISTER, AND DIFFUSER FRAMING, INCLUDING BORDER TYPES, T-BARS, AND CROSS NOTCHES. 0 :5 ^ o p !_ 3. FRAME TO FIT LAY-IN CEILING NO SCREW HOLES. 121N m SPIN IN COLLAR 4. PROVIDE WITH MISC. CEILING GRID TEES. D v ` 1 L LAY IN DIFFUSER V 6 ?;?; o PER SCHEDULE ,\ \ \ y J Q) U. a ¢ O VENTILATION AIR SCHEDULE L� L a 1 LAY-IN CEILING DIFFUSER AND BRANCH DUCT LAY-IN SLOT DIFFUSER PER SCHEDULE I z Q 5 2014 OREGON MECHANICAL SPECAILTY CODE U - r M-101 NO SCALE (2014 OMSC) MINIMUM VENTILATION RATES MA 2911 4 LAY-IN CEILING DIFFUSER AND BRANCH DUCT ROOM NAME ROOM NUMBER ZONE FLUOR ZONE TABLE 403.3 MINIMUM 1ABLE 403.3 MINIMUM TABLE 403.3.1.2 OUTSIDE AIR SUPPLY RETURNcc, pROFEv AREA SQ. FT. POPULATION VENTILATION RATE VENTILATION RATE ZONE AIR DISTRIBUTION BASED ON AIR AIR ��� GtiNER 0?r M-101 NO SCALE (Az) (Pz) (CFM/PERSON) (CFM/SQ. FT.) EFFECTIVENESS (Ez) 2014 OMSC -`,0 <c,‘." -7 OPEN OFFICE REFER TO PLAN 6595 33 5 0.06 0.8 701 8650 a 79 ,33PE PRIVATE OFFICES REFER TO PLAN 575 4 5 0.06 0.8 68 1000 1 CONFERENCE ROOMS 501,502,535,536,537 965 30 5 0.06 0.8 260 1550 1r 2' 14 BREAK ROOM 522 1195 6 5 0.06 0.8 127 1875 ,� ` • '��0'l � TRAINING ROOM 523 1240 62 5 0.06 0.8 481 2675 �L.A�Y 8. MOTHER'S ROOM 540 115 1 5 0.06 0.8 12 75--At-- S. GRA RECTANGULAR DUCT HANGER SCHEDULE I BAR JOIST OR PRINT 534 220 1 5 0.06 0.8 23 300 CORRIDOR REFER TO PLAN 1280 0 - 0.06 0.8 96 250 Lii PAIR SPACING: 10 FT. 8 FT 5 FT. 4 FT. OTHER D LOW PRESSURE RIGID ROUND DUCT PER DUCT PERIMETER, STRUCTURAL STORAGE 538,541 375 0 - 0.12 0.8 56 125 ® EO Z, INSULATED FLEX `,1+ !Il�II ��DRAWINGS MAXIMUM HALF STRAP WIRES STRAP WIRES STRAP WIRES STRAP WIRE/ COMPONENT Wj¢ (MAXIMUM 8'-0" LONG) L ROD ROD ROD ROD �� TOTAL FIFTH FLOOR 1812 16500 14688 IN.x GA IN.x GA IN.x GA IN.x GA I UIL0 0 I I I I r� Pr2=30" 1 x 22 10 GA 1 x 22 10 GA 1 x 22 12 GA 1 x z2 12 GA I PROPERTY MANAGER TO ADJUST OUTDOOR AIR SYSTEM TO COMPLY WITH OUTDOOR AIR REQUIREMENTS. W L M J I �(1 (.135") (.135") (.106") (.106") _ limil-O I L P12=72" 1 x 18 3/8" 1 x 20 1/4" 1 x 22 1/4" 1 x 22 1/4" SPIN IN WITH LOCKING P/2=96" 1 x 16 3/8" 1 x 18 3/8" 1 x 20 3/8" 1 x 22 1/4" GALVANIZED DIFFUSER METAL QUADRANT DAMPER (TYP.) P/2= 120" 1.5x16 1I2" 1 x 16 3/8" 1 x 18 3/8" 1x20 114" STRAP TERMINAL UNIT SCHEDULE (SEE GRILLE, REGISTER & 0 IW DIFFUSER SCHEDULE) P/2= 168" 1.5 x 16 1/2" 1.5 x 16 112" 1 x 16 3/8" 1 x 18 3/8" c = 0 Ii� *TRANE V P/2= 192" NONE 1/2" 1.5 x 16 112" 1 x 16 3/8" 1 x 16 3/8" .. P/2=193"+ SPECIAL ANALYSIS REQUIRED PLAN MARK *MODEL SIZE CFM STATIC PRESSURE NC LEVELS FAN ELECTRIC HEAT COIL NOTES INSULATED SHEETMETAL DISCHARGE1] .-- -L--le_ L VARIABLE VOLUME BOX SINGLE HANGER MAXIMUM ALLOWABLE LAP JOINED STRAPS, MINIMUM LOAD RATED UNIT OUTLET' MAX MIN. INLET DOWN MIN. RAD. DESCH. CFM ESP HP CFM KW V/PH. STEPS E.A.T. L.A.T. PLENUM (MINIMUM 5'-0" LONG) VAV (SEE SCHEDULE) LOAD FASTENERS(PLACE FASTENERS IN C- SHEET METAL W RUBBER VIBRATION ISOLATORS & SERIES, NOT SIDE BY SIDE): SCREW FP 5-1 EXISTING 100I 850 230 8.0 90 1 �� WIRE/ STRAP FASTENERS WIWASHER FP 5-2 EXISTING 80 - 750 150 - - - - - - - - - 4.5 - - - 90 1 • l 3/8"ALL THREAD ROD (TYP. OF 4) STRAP WEIGHT ROD WEIGHT VAV AIR INLET - - IN. x GA (QTY)- SIZE FP 5-3 EXISTING 80 750 150 4.5 90 1 IN.x GA LBS. 0(IN.) LBS. (2)-#10 SMS or FP 5-4 EXISTING 80 - 600 150 - - - - - - - - - 5.0 - - - 90 1 STRAIGHT RIGID ROUND 1 x 22 260 0.106 80 1 x 18,20,22 (1)-114"0 BOLT FP 5-5 EXISTING 80 - 900 150 - - - - - - - - - 3.0 - - - 90 1 DUCT MIN. 3 DIAMETERS 1 x 20 320 0-135 120 1 x 16 (2)-114"0 BOLT FP 5-9 EXISTING 100 - 1025 230 - - - - - - - - - 8.0 - - - 90 1 1 x 18 420 0.162 160 1.5 x 16 (2)-3/8"0 FP 5-10 EXISTING 100 - 1275 230 - - - - - - - - - 8.0 - - - 90 1 TRANSITION TO VAV 1 x 16 700 1/4 270 INLET SIZE STRUCTURE FP 5-11 EXISTING 80 - - - - - - - - - - - - 4 1.5 x 16 1100 3/8 680 NOT REQUIRED FOR FP 5-12 EXISTING 80 - - - - - - - - - - - - - - - - - 4 STAINLESS STEEL BANDING 1/2 1250 Zir DUCTWORK WITHFP 5 13 EXISTING 80 900 150 - - - - - - 4.0 - 90 1 STRAP (TYPICAL) 518 2000 -� LESS THAN 6 SQ.FT. 12" r HANGER STRAPS` CROSS-SECTIONAL FP 5-17 EXISTING 80 - 875 150 - - - - - - - - - 3.5 - - - 90 1 FP 5 18 EXISTING 80 - MEDIUM PRESSURE CONICAL FITTING 3/4 3000 (SEE CHART) AREA MAX- 4 INSULATED FLEX NOTE W TABLE ALLOWS FOR DUCT EIGHT, 1 LB!SO FT. INSULATION WEIGHT,AND NORMAL 60 in.MAX. UNLESS FOOT OF FP 5-21 EXISTING 80 600 150 - - - - - - - - - 3.0 - - - 90 1 § (MAXIMUM 3'-0" LONG) (3 REINFORCEMENT AND TRAPEZE WEIGHT STRAP IS PLACED FP 5-23 EXISTING 80 4 UNDER A BOTTOM �JJ REINFORCEMENT \ W 5-1 EXISTING 80 - 800 150 - - - - - - - - - 2.5 - - - - 1 O MAIN SPIRAL SUPPLY DUCT (� (MEDIUM PRESSURE) W 5-2 EXISTING 80 - 550 150 2.5 1 �� CNV ' it W 5 6 EXISTING 80 800 150 2.0 1 Z O a e c � d'. �� /v� 2 VAV BOX INSTALLATION DETAIL IL ° d 4 \ SCREWS W57 EXISTING 80 - 800 150 - _ - _ _ _ 2.0 - 1 O a 1 in. W 5-8 EXISTING 80 550 150 2.0 1 • ZilMilj 4 M-101 NO SCALE a e e a4 a a� MIN. W 5 9 DEMO $0 5 • • HANGER W5-11 EXISTING 60 3D0 100 1.0 1j _ \\* W 5-12 EXISTING 60 - 250 0 - - - - - - - - - 1.0 - - 1 la >T- _r msSTRAP LOADRATI D W 5-13 DEMO 60 5 F \--WASHER - WASHER FASTENERS VV 5-14 EXISTING 80 - - - - - - - - - - - - - - 4 0 NUT BAND OF SAME SIZE • - - - AS HANGER STRAP W 5-15 VCEF 100 14x12 1000 230 1.0 0.25 0.14 24 28 - - - 675 7.5 480/3 2 55.0 90.1 3 EQ. ON COLUMN OR 1'-0" W 5-16 VCEF 80 11x10 600 150 1.0 0.25 0.03 23 29 - - - 400 4.5 480/3 2 55.0 90.6 3 a NOTE: EQ. W 5-17 VCEF 120 17x14 1400 325 1.0 0.25 0.13 24 27 - - - 700 7.5 480/3 2 55.0 88.9 3 PROVIDE INTERMEDIATE BLOCKINGFROM EDGE OF WALL FOR DEVICES AS REQUIRED FOR \ /' F.A. VISUAL SIGNAL W - • WASHERS MAY BE OMITTED I ) W 5-18 VCEF 80 11x10 775 150 1.0 0.25 0.05 25 28 - - - 500 5.5 480/3 2 55.0 89.8 3 t I 6" 1 -0" WITH 100 LB MAX LOAD ON 36"0 MAX. PLACEMENT AS DIMENSIONED / .- 22 GA STRAP WHEN FOLDED 24"0 MAX. NOTES: 1. EXISTING UNIT, BALANCE AS SHOWN UNIT HAS ELECTRIC HEAT, SET HEATING PRIMARY CFM TO PROVIDE 90 DEGREE DISCHARGE TEMPERATURE. F.A. VISUAL SIGNAL WHERE APPLICABLE ----' t \ � \\ 2. EXISTING UNIT, BALANCE AS SHOWN. NV - I EDGE OF COLUMN OR WALL N 3. PROVIDE WITH ELECTRIC HEATING COIL, FIBRE FREE LINER, DISCONNECT SWITCH (DOOR INTERLOCK TYPE), PRESSURE INDEPENDENT BUILDING STANDARD THERMOSTAT I TELEPHONE, OR A VO EVICDE I 5 DUCT HANGER DETAILS DIGITAL (DDC) CONTROLS, AND BUILDING STANDARD THERMOSTAT. DDC HARDWARE, INSTALLATION AND PROGRAMMING SHALL BE IN ACCORDANCE WITH j 6' PROPERTY MANAGEMENT REQUIREMENTS. M-101 NO SCALE ADDITIONAL DEVICES \ 4. EXISTING UNIT NOT IN SCOPE OF WORK. SHOWN FOR REFERENCE ONLY, NO CHANGE. I 5. DEMO EXISTING UNIT. U U ` I I� THERMOSTAT (TYP.) WHERE MULTIPLE SWITCHES OCCUR, / Ii n LJ GANG WITH SINGLE COVER PLATE M'� ' H 1 I THEN LOCATE THE OTHER DEVICES / LIGHT SWITCH (TYP.) CENTERED OFF FURTHEST LIGHT SWITCH L co A I > DUCT INSULATION SCHEDULE W tiH- MAINTAIN MINIMUM 12" CLEARANCE IN FRONT OF SWITCH OR DIMMER - ° I DUPLEX RECEPTACLE, FLOOR/ROOF DUCT OPENING AND 8" CLEARANCE ABOVE. ..-j 60 _ COMMUNICATION OUTLET, ETC. CONSTRUCTION COORDINATE WITH ALL OTHER TRADES TO ENSURE MATERIAL FIELD VAPOR D DOOR OR SIDE LITE FRAME Z9 ABOVEN. THIS CLEARANCE IS MAINTAINED. THICK- NO. OF 0 cm (TYP.) ID TAG BTU.IN / IB FORM R-VALUE APPLIED RETARDER W �"0 d K H.SQ.FT.F AT75F D; NESS LAYERS FT JACKET REQUIRED F- / C° 6 6 6 4 ( 1 MINERAL FIBER BLANKET a a 4 (0.2610.75) N/A 1" 3.8 ONE FOIL & PAPER YES 0 I I ' s„ 1 Cl) 3 CENTENE DEVICE LOCATION DIAGRAM 1 _ L i_ D � -�-12"� © LINER N/A 1" 4.2 ONE NONE YES "'� Cl) M-101 1"ACOUSTICAL (0.2411.5) < NO SCALE 2xD MIN�� LINING / D OUTSIDE DIMENSION Q / PLANS NO SIZE SHOWN)(U5 O 2X8 IF GENERAL NOTE: DUCT SIZES INDICATED ON DRAWINGS ARE SHEET METAL SIZE AND INCLUDE LINER SPECIFIED. Q W SPECIFICATION FOR LOCATION OF DEVICES OMIT TURNING VANE _ A. WHEN MOUNTING MULTIPLE DEVICES FROM DIFFERENT TRADES IN THE SAME LOCATION (SUCH AS LIGHTING 6" MIN. 0 0 SWITCHES, THERMOSTATS, ETC.), THEIR ARRANGEMENT SHALL BE IN ACCORDANCE WITH THE FOLLOWING: / W Z 1. LOCATE DEVICES AS SHOWN ON THE ARCHITECTURAL PLANS, ELEVATIONS OR SECTIONS. / 2. WHEN SHOWN ON MECHANICAL OR ELECTRICAL DRAWINGS, BUT NOT ON ARCHITECTURAL DRAWINGS, DEVICES CEILING , CEILING SHALL BE UNIFORMLY AND SYMMETRICALLY MOUNTED. VERTICALLY ALIGN DEVICES MOUNTED AT HEIGHTS / INDICATED, UNLESS SEPARATED HORIZONTALLY BY A MINIMUM OF 24". DATE 05/23/2018 1 3. DEVICES INSTALLED IN MASONRY OR SURFACES TO RECEIVE WOOD PANELS, WALL COVERING OR SIMILAR WALL MATERIALS SHALL BE INSPECTED BY THE ARCHITECT AT TIME OF ROUGH-IN. SCALE AS NOTED 4. IF THE CONTRACTOR HAS ANY DOUBTS REGARDING THE LOCATION OF DEVICES, HE SHOULD CONSULT WITH / THE PROJECT ARCHITECT/ENGINEER PRIOR TO ROUGHING-IN. MCR JRA 5. CONTRACTOR SHALL CONFIRM THE FINAL LOCATION OF MONITORS WITH THE TENANT PRIOR TO ROUGH-IN. AN SIGNALS SHALL BE A MINIMUM OF 36" HORIZONTALLY FROM ANY MONITOR. J4B 6 RETURN AIR BOOT - PLENUM TO PLENUM CENO14 B. DEVIATIONS FROM THE ABOVE PRINCIPLES WITHOUT PRIOR APPROVAL BY THE ARCHITECT/ENGINEER SHALL BE M-101 NO SCALE SHEET CORRECTED BY THE INSTALLING CONTRACTOR. ANY COST, INCLUDING CUTTING & PATCHING, ENTAILED IN THE REMOVAL, 10_101 RELOCATION, AND REINSTALLATION OF ANY DEVICES SHALL BE THE RESPONSIBILITY OF THAT CONTRACTOR. OF SHEETS IHDL DESIGN HEREBIEXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. • I I N REVISIONS BY 2 i o8 a O P Lte' (:),% oi cr:".: 4 woc.). 1. • m N L7 O Q 8 M � Z w F O ,„D Z J U ci 0 3 C7 • �' 04 Ej -gt GENERAL NOTES - MECHANICAL DEMOLITION El PLAN NOTES - MECHANICAL DEMOLITION it z i• n E r A. UNLESS OTHERWISE NOTED, EXISTING DUCT, SUPPLY DIFFUSERS, RETURN AIR GRILLES, 1. CAREFULLY REMOVE AND RELOCATE EXISTING THERMOSTAT. EXTEND CONTROL WIRING TO C.5 V p m CO TRANSFER AIR GRILLES,TERMINAL UNITS AND HVAC CONTROLS SHALL REMAIN AND BE NEW LOCATION- 3 c (j `� o REUSED. PROTECT FROM DUST AND DAMAGE. Z I- {f} E• v e 5::-., 2. CAREFULLY REMOVE AND RELOCATE EXISTING SUPPLY AIR DIFFUSER. REMOVE FLEX DUCT. 6' g. Z c d a B. TURN OVER TO PROPERTY MANAGER/OWNER OR PROPERLY DISPOSE OF ANY REMAINING CAP AND SEAL MAIN DUCT IF BRANCH DUCT IS NOT REUSED. {O} ^ ^ °i t REMOVED AIR DEVICES AFTER RELOCATED DEVICES ARE ACCOUNTED FOR. " ^ v 3. CAREFULLY REMOVE AND RELOCATE EXISTING RETURN AIR GRILLE. D 0 �n n %°% o U• ° 4. TEMPORARILY SUPPORT DIFFUSER(S) FOR GRID REMOVAL AND REINSTALL IN NEW GRID. JN > 9 w 3 5. REMOVE EXISTING RETURN AIR TRANSFER. a v0 d `` 8 0 6. REMOVE EXISTING RETURN AIR TRANSFER WITH FIRE DAMPER. Z ■ - t 7. REMOVE EXISTING VAV BOX ABOVE CEILING. REMOVE ASSOCIATED CONTROLS, DUCTWORK, MAY 2 3 2013 DIFFUSERS,AND THERMOSTAT. v P R OFE'Ssi 8. REMOVE EXISTING SPLIT SYSTEM FANCOIL ABOVE CEILING. REMOVE ASSOCIATED �tc, �0,1NEE/1 0?. THERMOSTAT, DUCTWORK, GRILLES, DIFFUSERS, CONDENSATE AND REFRIGERANT PIPING Ca 9f AND CONDENSING UNIT ON ROOF. PATCH AND SEAL ROOF RAIN TIGHT. s 79 33PE 9. REMOVE ALL EXISTING DUCTWORK AND DIFFUSERS DOWNSTREAM OF EXISTING VAV BOX. r 6,t4 4$ 10. NO HVAC WORK IN THIS AREA. l � ' • FG,�:/ter W 0 0 W6 _ ZILI 0 oo ED 0 0 0 0 �_ —-- 100(E) 4180141------.._ o o ,-,-,, 1-5.100(E) 100(E) ` �� 100(E J i� 1o0fE �r { 11 101107.,;;;;•,T=y 100{E� 100{E} , � I � I � I - _ � 0Two:7 // VArOrr' •, 0 . :., ._ „„ „ „ ,___,Iii, , O iU0IE1 f 10fd(E} 1 E24 iD0(E} 1041(E) 100(E) 4 100(E) 4 100(E) TitoT. . T/ n Oaf ]❑ ❑ - n ,❑ ❑- -,-,d, nall cw i I{ 100(E) / 1 C- I' �� , m77/4 or 4. tAA r61- 1 FP I //NW MIll 1 C 1 1 . , II I is♦ n % %/ 100(E) , n Tri- . -._ I �%,.,.. LI,moi 2 �,,//rf . .' r ,[] ❑ _ / 'f , 1 =I 11.1M.MIIMMI MI ..._Of I .GIB, 0 IM,. ..M.01/ 11M., ...--- i, m{E) I IAla / / I /'�%%/ �,/ /. I ® 111 it 1=1. / 5 I 114 _ _ 70 § j6„ g ® jam/ ❑ �/ I / /////7// , / . lir+ il".".....) /, i) /#1V#7i/i.Y / 0 ) . , I 10 ///: 5 'r ,or i ./ •i1 I 1 i , • / ilii //L Ii. ' I / 10 r. o . F% fir., i i> , ` `� -Amilko2 '11%/ 4 , • % /� / // ,� AA la c��/ / .. /� 80{EJ -mssII .�� %ill ( / �4 / �� ril /1o P❑ f.e 12I �j / 1 //ice / ' / / /; _ /;� ; ' Z jai r/ft31.4. rr/ , / -s laOEe g 100(E ;. ��., / /` / /�/ / i ' , I / / Z 1 /AI", '�f' ,� / 4., ,/ ,�' / /, '� / ��� la 1 i 7,/,,A0I,,I //-''' ..,....,i 7-4, 80(i 0 • / E '', '. .7- 1 �� I / 7// 00r /,. ' l'' l'' / I 7iA OA%./, /.,..4/ A_,4,7 © % Mr-TW / / / , /' ....MD . : ENF0 '0A4 e 7 0 : 100(E) I , t, �i��� i !� _�1' a. ( ' / / /'/ • Ala I / , / A A ' 0 A ��•� ®Box , pi t I / ® '7T / ;/ 80{E) 1 ry `t � ,/,/,,, , / //� I rl A/„.P / ......41 •111 MP 11 ,IMI-i.=,. 10.1111P igh,1=1' F M ' M' 'M ' / // ars m m ■ iji lh r , / ,� /. • _ _ ,,___. _ �� � /<" CIO \�. 100(E) ,�', / ,�.,- 1fj in 41:41\ ;,... I% 14 �fl/..,.....r.=1 r 4 / / / /'/ // �i/i '/ r\ 4.III\ ��.- -�I�r ,, N ❑ ',� �/ © ❑ M. 1 1 1 ', //,/ 1VCNI 3 I .� / /.i//��::, / ✓i ❑ 1 /,' /2,., ,� 11 OM , �,���� //,/' 1 100(E) �•, 6 �J e _i_i�II_i_ % 100(E) I r//❑ Car C /Ite f Y - / tel 80(E)NO I 80(E) kigtil 60(E) 1 80(E} �� �� ��� /� ❑ 6- I E El El I 100{E} ❑ 11 80{E) 4`� �3 r� / TL:\ip,- a�IE) ❑ %% // / ..� ,.,.� ❑ g. .1::rfr,trAr ,e,".4,3 , _ 1 1 —— — — h — /l // / / �1 /lam!' /t///T/7 % fr. i/''��' �� 7 fM (.1--j �';,. El'''."- % 100(E) / / - / 11 Mk /r15 ,/ /., .3 / jjoir /life /, _ ././In ({ — —ri I1 b -4, Iiia. i .,- 5-9 L /❑ �� J /. Z/ /i a0(E) I e0 ,Doi E C _ _______ .i. litr r---1 _ zs. 0, . cc i J ,A. I _. . , , 0 8 w .1, ....± ..„•&//,.; 'm „..,),,,,/7„ FP f I = t xix III AM 3 u ----.---1 r .,.r. 5-18 I 3 5 ® . . T I I 5-8 ❑ FP7 4, I/ I FP 5-9 ,,,,,,..i 7 .. . ,,., .ii, , .,.., ,, : , -.,„ .4,. , I, ,,,..„,, ,,,, `,77 ET CI V �I�' / / //�PIA -i-� 0// 0I/ - % i �_�_�_ / -MEI /� „..y , / . LL 1 / 7 , i , i / lir _ _ . / ., . 100(E0 i„) /ii❑ ______4,71(4,,,,0,E) [XV Wr =<C 2 kl �� ' t r' ///�iL�� , 1111:1W=-171--r ./.4 , til -10 r TV ! 1.1 FP ❑ L[! -1(:). I , . Q W W %!� LL toP <)-7\-(> ' • ❑ I ❑gak ��. ..,,/,),/,(> 100(E:) r4� �E _ _ _—A L AZ: 100(E) 100{E) r "� ' L— — — — GATE 1M , 05/23/2018 ``I— __`-_- ❑2 10 % SCALE AS NOTED lora(E) 100(E) O MGR JRA U 0 U o © - '-fel �,�1_' 0 8 JOB CEN014 SHEET /t PARTIAL FIFTH FLOOR CEILING PLAN - MECHANICAL DEMOLITION N SCALE: 118" = 1'_0„ M- 201 OF SHEETS IHDL DESIGN HEREBI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I P. REVISIONS BY I F dam" 8 Cl 0o it Orel Q O%0 0 n G3. GCS -i N C7 ,F O Q 8e Z r O �z Z GENERAL NOTES - MECHANICAL 0 PLAN NOTES - MECHANICAL w z z A. EXISTING DUCT SIZES, DUCT LOCATIONS, EQUIPMENT SIZES, EQUIPMENT LOCATIONS, AND H. ADEQUATE SPACE SHALL BE PROVIDED FOR THE FIRE SUPPRESSION SPRINKLER PIPING 1. NEW LOCATION FOR EXISTING THERMOSTAT. EXTEND CONTROL WIRING TO NEW LOCATION. od r aZ 0 AIR DEVICE SIZES WERE OBTAINED FROM EXISTING PLANS OR LIMITED SITE COORDINATE DUCT ELEVATIONS WITH FIRE SPRINKLER CONTRACTOR PRIOR TO START OF CUT AND PATCH AS REQUIRED. MOUNT AT 48"AFF. -L4 o ¢ Z OBSERVATIONS AND SHALL BE CONSIDERED APPROXIMATE. SITE VERIFY EXISTING CONSTRUCTION. Z G g c ■ o DIMENSIONS AND LOCATIONS DURING BIDDING PROCESS AND IDENTIFY ANY 2. NEW LOCATION FOR EXISTING SUPPLY DIFFUSER. CONNECT TO EXISTING BRANCH DUCT cri) C7 V Z n 0 N U DISCREPANCIES PREVENTING THE NEW SCOPE OF WORK AS SHOWN. I. COORDINATE DUCT OPENINGS IN THE WALL FRAMING WITH THE FRAMING CONTRACTOR WITH NEW FLEX DUCT, RIGID ROUND METAL DUCT OR PROVIDE NEW TAP TO EXISTING MAIN Z ?:'1,' O 0' g PRIOR TO START OF CONSTRUCTION. DUCT. W < LW Q • 1.7 Q B. WHERE WALLS ARE EXTENDED UP TO DECK REPLACE FLEX DUCTS WITH SHEETMETAL yZ. .d, Z {f a P Q of DUCT THROUGH WALL. J. OFFSETS AND TRANSITIONS ARE TO BE PROVIDED FOR COORDINATION WITH OTHER 3. NEW LOCATION FOR EXISTING SUPPLY DIFFUSER. REMOVE TEMPORARY SUPPORT AND ❑ A c Z n} - j, k;, a� SYSTEMS AND THE BUILDING STRUCTURE. REROUTE EXISTING FLEX DUCT TO DIFFUSER LOCATION. REPLACE FLEX DUCT AS REQUIRED. 0 ~Y °� o �` �` � a, n n C. WIPE CLEAN FACE OF EXISTING SUPPLY DIFFUSERS AND RETURN GRILLES. - . t K. PROVIDE ACCESS PANEL WHERE REQUIRED FOR HVAC DAMPERS AND COMPONENT 4. NEW LOCATION FOR EXISTING RETURN AIR GRILLE. t D. PROVIDE INSULATED BASE FOR THERMOSTATS OR SENSORS LOCATED ON EXTERIOR ACCESS WHEN INSTALLED ABOVE NON-ACCESSIBLE CEILINGS. U -'�' g WALL OR COLUMN FURRING THAT IS INTEGRAL WITH EXTERIOR WALL. 5. PROVIDE VARIABLE AIR VOLUME (VAV) BOX AS SCHEDULED AND SPECIFIED. EXTEND I W x o L. COORDINATE ACTUAL ROUTE OF SUPPLY, RETURN, EXHAUST DUCT, AND MECHANICAL INSULATED SUPPLY AIR DUCT FULL SIZE FROM UNIT CONNECTIONS AND TRANSITION TO DUCT a U C7 a_ t. ei E. WHERE DUCTS PENETRATE THE ASSEMBLY, FIRE STOP CAULK SHALL BE APPLIED IN PIPING ROUTES IN THE FIELD. COORDINATE WITH ARCHITECTURAL, ELECTRICAL, SIZED AS SHOWN. INTERLOCK WITH WALL MOUNTED THERMOSTAT. Q o 5 ACCORDANCE WITH MANUFACTURES INSTALLATION GUIDELINES AND U.L. LISTED TESTING PLUMBING, FIRE PROTECTION, AND STRUCTURAL CONDITIONS. Z ■ -r 1 APPROVALS. 6. PROVIDE TRANSFER AIR SLEEVE HIGH ABOVE CEILING SIZED AS SHOWN, REFER TO DETAIL -c M. COORDINATE DUCTWORK DROPS WITH STRUCTURAL COMPONENTS. 61M-101. F. THE MECHANICAL CONTRACTOR SHALL PROTECT ALL OPEN DUCT, PIPING, AND 0,p PROFEss. I MECHANICAL EQUIPMENT, NEW AND EXISTING FROM CONSTRUCTION DUST AND DIRT. N. EQUIVALENT AREA DUCTS AND MODIFICATIONS TO LAYOUT ARE ACCEPTABLE BASED ON 7. NO HVAC WORK IN THIS AREA. /\<<" �G1NEE-R 10„,9! MECHANICAL SYSTEMS SHALL NOT BE OPERATED DURING CONSTRUCTION EXCEPT FIELD CONDITIONS AND COORDINATION. WHERE WRITTEN APPROVAL IS OBTAINED FROM THE ENGINEER AND OWNER. WHEN / -L7.533r� APPROVAL IS ISSUED, PROTECT EACH RETURN AIR DUCT OPENING WITH MERV 8 FILTERS 0. PRIOR TO THE START OF CONSTRUCTION, THE MECHANICAL CONTRACTOR SHALL AND INSTALL MERV 8 FILTER(S) IN EQUIPMENT FILTER RACK. PRIOR TO TESTING AND COMPLETELY REVIEW AND CONFIRM THE INTENDED RETURN AIR PATH TO MECHANICAL BALANCING, REMOVE FILTERS AND INSTALL NEW MERV 8 FILTERS. AT COMPLETION OF EQUIPMENT IS OPEN AND WILL BE FUNCTIONAL. CONFIRM AGAIN, PRIOR TO THE AIR .•, ck N,\• 44/Q- A REMOVE CONSTRUCTION FILTERS AND REPLACE EQUIPMENT FILTERS BALANCE OF THE MECHANICAL SYSTEM. 'f� Y 8 2p§ �'4` WITH NEW FILTERS. LN -kS P. COORDINATE LOCATION AND SUPPORTS OF MECHANICAL UNITS WITH OTHER TRADES. i, . ` G. ELBOWS IN MECHANICAL SYSTEMS DUCTS SHALL BE HELD TO A MINIMUM. COORDINATE LOCATION OF DUCTS WITH OTHER TRADE CONTRACTORS PRIOR TO STARTING WORK. MAY 23 20!8 W o w ilia a 300 ® ® ZR 0 300 300la co 300 6 7 ® ED ° a a n a o 0 0 H ® ® ,oO(E) ,+ ,00`(E) ,,a0(t, z 8 x, wir „'• ,00(E r`, 1® 250 250 z� ® ® 2® 2® 2® 1a (E ,o0(E! _ N® — . 1 I . V r M. U c 7///1/ Art // / ,c)F00(E 1 100(E) 100(E) !1 100E jFP5 z . /// /, /"/ / 7 Ae .-f- !- -, 0 00(E 0 r . 100 1��,_ �. .. _ I FP i-2 � � J/ -. _ I NOTE _ IS FP 5- Pi? V/t /A/AwP, /"F /// / - ---"Q----\ ® ,(E) /`=X 1 400;E) FP/ 1 G�N-. O�l G"I ' T^ / ' / , - , /iii, 011 .i../ 150 N` ` ,� C 5-2 ® ,. 4 I 5c,, 0 a21� ,).{1 /4”. I , O 0 EM CIFFI CE 4 An❑ _,(FP - O I ��1 7 ID f:�..-�/2faoI -"I 1 , / LE B 3'7,-31 Mr ILI _ 5-3 i 1 � TYP.OFS� , . n / I ❑ E R I: / / //I/ ,.ji / F CE 3 FP ,1 4x10 a 14 .14 80 1 i 1 4 100 E,-S ❑ �IP 5z ii(//77/ T 80 ti 3 80 00 , , \ �,. f / Al5311IQ Er-R I 80 I ® 2�� : .SD n n ��'M Q . I,•150 1 4 . -.I. I I _,: U -._ 100[_ ,�� / ��„Uh / / / / VVV FP ^ o �-1\ �V o ... _ 1. FF5 1 1 W'-12100 4e` / ,� �j ��/ ' A A'Aer 4/ �. I _ , QBE 1 4 An YIPV ItOfd d. r • / SD ..�-----� � , �3i 0 W5 i5 �, © J 1 9-10NE ® / / /,./v, /;r e F.A /�150 4f� zerI��/ 1<L7150 ' N �} �_ r L - .� �. i X39 / 4 . 12 'IriG',, I ' . l' / ,,: -.:- ❑ IDS)-E 1110w51 i._ (572w 80❑ ^ ( a ./ I I /I s5 I u�. ! E ;? • ®17 �N -.-�.......__ ; . . . / i /.././ /, fIr i�:r To,A ri / J �' /�• { ` ' � -�I -- �_ _ ® O CD= IC- �7 4 El b 10x[4 4 fi0AIL..� . (� 1 - IU • 7r, 0/7// ,./ /� 7: ' ,iii, /',,,-.-- --v ,vr 11' 4,-Fr,or zt §r N . //%IC. /I 1. 1"11 & A A.O.ill 0 , / SA i \,: _ ed AZ flifg4101Ag ••plir / 2L, ch 427 . ' (1)FP 5-17 VW 0\ — // .4/ , la t re 6 ❑ // ,Li - - �� in 60 I I 1976.' 4 4 ter. / . t 1 1 / zi-rt) / : - 71 1t' -. , r , it = od„ .wAr .ff. 774 AA AP" �.1-_�__ / . 101 I ---- • - n �— 7 1 IBMk� `/ / / /_ / QIP c 100p- , , A 1/ ,..4 /�60 tal, y #, / Ai I; I 2 — es? 8� rim/ ii/iirpe: ' —� rl. --- , �J �� /. �/ / 1 l• y I ��= . . .44 i-i-.--fi//Jf/-- - - - W QI �117 � � I� / / ❑ n / - * 4#', ø / / AO, Gm r r F_ 1746orir4r / �— _ 1012 o , ❑, ° • /: f f l r �. ��I� .....1 �_ 1 2 � LI,J.�� ,_- 1,0,/ ///� /' - ti SR ® �► !N ® _ n NCpN-R41TEzb C�c�i Rl�CIi:C ff /� - ii I ��!�• _71 240 5 1 -�-�- I I W , 1 ,� �, O y I 1 �-+ _ (TYP. F 2) I— LJ / �� f 100 CID \\... ———— �.� 7 . , gi , 1 a ``TlJ L� 0lig� ��/ �4� lir MI 1.0 Of I t Ii N ///1 100 -mow s � E>, • ICE 3 .. - �` / �, /X / �� 60 �y�►a C - tV, i , 804 _ 6121 _ I 00 5-11L / _ _ /�` I I "' eI �3 Klv\_/) MOfiN 5kI\0 /n _ _ illiiii �__ __�_ __ 4 \ 80L j W 80 6B J{E) ;Irs 60(E) �4♦ n n ® �W �_ F'5 11 Illi.iyl�i�r �� :0,VA fir 0 , ,, . 5 16� I 71Er T r� - /7/41 / / ! 1 - y / ' 1 n n IV 11' II X15-1SJ // 1"17 / y'ir AN ,,,„.., 4 150 1:x12 E? RIiii7fillia ►1 EX-R J Y 1-�! w 0j- -- - lif I T agarak \ rUfr / El. 4 2x1 (TYP.OF 4) 0 E)--R I _ T --.100 ilEN 11 MP 0 47CJ �,3 r 1 h ir.4. r // �, .1 1 • Aft— . , 4 ? 240 ' 00 lo,;__ ±1100 ® ► 2 1 / '//,r, /,� r ►. - O ° y_ n o �_ o n �TYP.OF2) n A ` I 1 L1 �❑ /�._, .. U 111 '' -'— I Q --- [XI 75 ® 5-18 \ ri %/ / /API _ �J I' I / 60 1E I B0(E: V 12� NW �� .�z 1� , Ar - - - - - L / ' / I - (TYP1.'OF`3) - - ..•�.irrio. 80 - '� 60(f�' - 11 ' 00 - — �� 3l0 �f �ht i K ❑ ���� �� .>/� 1 • y�lCC 190(E) A ® I- iT I ` •- (TYP.OF 4) I�X Li i, , 52 / �J/ O 0 ii r '• kim 1 D9 .© "� T �I/� W n • /,1 5P 2�0 �n'v V CTI' "3 0 r Ifs c.r 80 FP s0 '�I ��/ / �--� Co P5S n 1 (TYP.-OF 4) . IT o {TYP.OF 4) o 0 /7/7 —r, �m1 ❑ w 6�T �� / FP T �. 5 8 �' I 111 L: ( 5-1 SII 1/ / .! 7Lim !S b �/ �, [_____2" 100 100,. . 1 _ E 1 /7 V ' = I rn N 11213 lw / II' �� ice' ��� I/1 �� ► — 44- /.'"'Ffilir.alik G Z El 2 J ; -_. ► a..-..-wwiwwe-•w..w.•4.wll.kr —w�-�w ......-��- - %" �' ,�,,, a ❑ 100 ^ >29 4r+ / ..� �I� w. r A. � ....1.L. � �i%/ An �■r ''�� J% 4!,��'/, i — mil � .� / 2� ��! -fel i . _ f 1006...„( 1012 1012A '" / i / 1 / / v 0) 111L 1�.� f� / �� _ i' % ' 7:47f1FAMIPrir� I //// /: ',Ff. Z� 4i. , ,_i ////' . . ../r. �Lr' /�/ .&e__.: a Z Mk Aft Mr 200 200 - A"i� l�J� joffirT. r yie 30(i=) 1 2:5USW 0(F) / I I• i ® ^Q rW� ! Z1E ,.. ✓ A / O �1 300 ■. - VwE �I•' v / Mwa� 1 FP 5 3 100 /. !��%��,�,,J�/ �i -- 11 Li-- ill)/ — '..'-r" ❑ 11/I/� , - /�2 T r- - 1� Ll ' - ""^}— 100{E) 100(E) — DATE iIi 'P / �"-_ FP 10 �;_ .._ _ 1 I t 05/23/2018 ' III I �—. -CO ® ® o e _______,, ____________, T10® �t ® SCALE AS NOTED 160(E) 10 1.1" 1i ______,,._____ 300 300 to ® ® . MGR JRA 275 EX-S JOB CEN014 / � PARTIAL FIFTH FLOOR CEILING PLAN - MECHANICAL SHEET N SCALE: 1/8" = t-0" M-301 OF SHEETS IHDL DESIGN HEREBY/EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE iT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMI1SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I C) REVISIONS BY 1 I- fn [�] g a T � ELECTRICAL CRITERIA ELECTRICAL CRITERIA (CONT.) ELECTRICAL ABBREVIATIONS ELECTRICAL SYMBOL LIST LOW VOLTAGE SYMBOL LIST ° og vr 1_ BEFORE SUBMITTING A PROPOSAL, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE OF WORK AND FAMILIARIZE THEMSELVES 17. TOGGLE SWITCHES SHALL BE 20 AMP, 120/277 VOLT, SPECIFICATION GRADE; SILENT ACTION, SINGLE POLE OR THREE-WAY. DUPLEX 1 PH SINGLE PHASE (LINE-LINE) OUTLETS Q I� o UO WITH ALL SITE CONDITIONS. ELECTRICAL CONTRACTOR SHALL CAREFULLY EXAMINE THE ENTIRE SET OF CONSTRUCTION RECEPTACLES SHALL BE 20 AMP.. 125 VOLT, GROUNDING TYPE. SPECIFICATION GRADE. GROUND FAULT INTERRUPTING V VOICE OUTLET BOX ^N C7 3PH 3 PHASE (L1-L2-L3) DOCUMENTS. SUBMISSION OF A BID WILL ACKNOWLEDGE THE ELECTRICAL CONTRACTOR HAS VISITED THE SITE AND EXAMINED RECEPTACLES SHALL BE 20 AMP. 125 VOLT. SPECIFICATION GRADE, WITH 5MA TRIP RESET AND TEST SWITCH IN FACE. DEVICES (D SINGLE RECEPTACLE(+18") Z 4- 3PL THREE POLE 0 ¢ T A,�; ALL CONSTRUCTION DOCUMENTS AND THE BID INSTRUCTIONS. ALL ELECTRICAL WORK IN THE CONSTRUCTION DOCUMENTS, SHALL BE WHITE IN COLOR. DEVICE COVER PLATES IN FINISHED AREAS SHALL BE SPECIFICATION GRADE, WHITE PLASTIC.AND • DATA OUTLET BOX Z oC M INCLUDING THAT REQUIRED BY OTHER DIVISIONS, GENERALLY INSTALLED BY THE ELECTRICAL CONTRACTOR,WHERE EQUIPMENT WITH CONFIGURATION REQUIRED BY DEVICE AND ARRANGEMENT. DEVICES AS MANUFACTURED BY HUBBELL. LEVITON, PASS AND 3PSN 3 POLE SOLID NEUTRAL 0 DUPLEX RECEPTACLE(+18") ¢ i__; L Q (60/50/3) AMP SIZE/FUSE SIZE/POLES VOICE/DATA OUTLET BOX 0 `"D Z W IS FURNISHED BY OTHERS, SHALL BE INCLUDED. IT IS EXPRESSLY UNDERSTOOD THAT THIS PROPOSAL IS BASED ON THE ABOVE SEYMOUR, COOPER OR EAGLE ARE ACCEPTABLE. WEATHERPROOF RECEPTACLES SHALL BE PROVIDED WITH "IN USE"TYPE COVER V A AMPERE(S) 0 QUADPLEX RECEPTACLE(+18") uZ U 0 REQUIREMENTS AND THAT IT COVERS MATERIAL AND LABOR NECESSARY TO COMPLETE THE SCOPE OF WORK DESCRIBED HEREIN. TO COMPLY WITH NEC SECTION 406.8(B)(1) FOR 15 AND 20 AMP RECEPTACLES IN A WET LOCATION. to I- Z A1C AMPERES INTERRUPTING CAPACITY wP 0i CAN OUTLET BOX ♦ w "' Z QD WEATHERPROOF RECEPTACLE .- AFC! ARC FLASH CIRCUIT INTERRUPTERv, >- O 2. ELECTRICAL CONTRACTOR SHALL PERFORM WORK IN A SAFE MANNER. COMPLY WITH APPLICABLE OSHA SAFETY GUIDELINES 18. IDENTIFY EQUIPMENT AS DETERMINED BY THE NATIONAL ELECTRIC CODE AS A MINIMUM PROVIDE TYPEWRITTEN PANEL Z Q W DURING THE COURSE OF PERFORMING THE WORK DESCRIBED IN THESE CONSTRUCTION DOCUMENTS. DIRECTORIES AND ENGRAVED PLASTIC LAMINATE LABELS FOR EACH DISCONNECT SWITCH, PANELBOARD AND TRANSFORMER AFF ABOVE FINISHED FLOOR GFI TYPE RECEPTACLE [=KI CCTV CAMERA cid w M - -' z W PROVCe IDE SIGN ON COVER AND FLOOR MARKING TAPE DESIGNATING NEC WORKING SPACE IN FRONT OF EACH NEW PANELBOARD AHJ AUTHORITY HAVING JURISDICTION ISOLATED GROUND TYPE D.R. ❑F MANUAL PULL STATION 3. ELECTRICAL CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ITEM(S)OF THE CONTRACT DOCUMENTS THAT ARE NOT LOCATED IN ELECTRICAL, MECHANICAL, STORAGE OR SIMILAR AREA. AHU AIR HANDLING UNIT 0 c ,� UNDERSTOOD OR WHERE CONFLICTS MAY EXIST. CLARIFICATIONS MUST BE PRESENTED AS A"REQUEST FOR INFORMATION"(RFL) AL ALUMINUM usa � -. �, p IN WRITING PRIOR TO SUBMITTING A BID. RFI SHALL BE PRESENTED A MINIMUM OF FIVE (5)WORKING DAYS BEFORE THE BID DATE. 19. TEST ELECTRICAL SYSTEM AND BRANCH CIRCUIT WIRING FOR SHORT CIRCUITS. MEGGER TEST FEEDERS AND ENSURE LOW ALT ALTERNATE Qp USB CHARGER RECEPTACLE LJ AUDIONISUAL ALARM HORN (+80") C.) U Z n i N U o OBTAIN THE RFI FORM AT WWW.GANDWATS AUTOMATIC TRANSFER SWITCH ENGINEERING.COM/DOCUMENTS. SUBMISSION OF BID WILL ACKNOWLEDGE THE IMPEDANCE GROUND SYSTEM. 0 SWITCHED RECEPTACLE W E w,7 V CO.C 0 Q o0 0o a ELECTRICAL CONTRACTOR UNDERSTANDS THE SCOPE OF WORK, MEANS AND METHODS OF INSTALLATION, EQUIPMENT AND AWG AMERICAN WIRE GAUGE AUDfONISUAL MINI ALARM HORN _ '1, Q (1) ,� 17 MATERIALS TO BE USED. RFI THAT HAVE NOT BEEN CLARIFIED PRIOR TO BID WILL BE PROVIDED BY THE ELECTRICAL 20. SERVICE AND PANEL FEEDER WIRING: USE TYPE THWN CABLE IN A RACEWAY. PROVIDE THHN/THWN CABLE FOR INTERIOR BRANCH BB BASEBOARD HEATER 0 D.R. TOP HALF SWITCHED Z C -" LID c /� '1 - ' ,1-,:-, L. CONTRACTOR,AS DIRECTED BY THE ENGINEER OF RECORD, AND THE MOST STRINGENT MATERIALS, EQUIPMENT,AND SCOPE OF CIRCUIT WIRING UNLESS OTHERWISE NOTED. DESIGN IS BASED ON COPPER CONDUCTORS AND THE MINIMUM SIZE OF#12 AWG. BDD BACK DRAFT DAMPER ® STROBE LIGHT ONLY(+80") ❑ T. 0 0 �y °� o � � WORK SHALL APPLY. NO ADDITIONAL COMPENSATION WILL BE MADE FOR THE FAILURE OF THE CONTRACTOR TO OBTAIN PROVIDE INCREASED WIRE SIZES, PER THE NEC. TO COMPENSATE FOR NO GREATER THAN A 3%VOLTAGE DROP WHEN THE BES BANKING EQUIPMENT SUPPLIER °F FLUSH FLOOR BOX. SEE PLANS. CLARIFICATIONS PRIOR TO BID. FARTHEST OUTLET IS GREATER THAN 100' FROM THE PANEL TERMINATION.WIRING SHALL BE IN CONDUIT SYSTEMS. SPLICE WIRES BFF BELOW FINISHED FLOOR US F.A. SYSTEM CEILING SPEAKER Q 2 o. -- °y #6 AWG AND LARGER WITH APPROVED SOLDERLESS CONNECTORS TAPED AND INSULATED. SPLICE SMALLER WIRES WITH BMS BUILDING MANAGEMENT SYSTEM Os SURFACE FLOOR RECEPTACLE. SEE PLANS. D v `° t° Q SMOKE DETECTOR(CEILING MTD.) tj THE ELECTRICAL CONTRACTOR'S BID SHALL BE BASED ON THE SCHEDULED EQUIPMENT, MATERIALS, AND MANUFACTURERS MECHANICAL CONNECTORS SUCH AS"SCOTCHLOCK".TYPE"MC"CABLE MAY BE USED FOR BRANCH CIRCUITS AT ALL LOCATIONS CKT CIRCUIT s U °%°% -,5- 4. 9 SPECIAL PURPOSE OUTLET. SEE PLANS. p� v WHICH FORM THE "BASIS OF DESIGN". ALL OTHER EQUIPMENT, MATERIALS,AND MANUFACTURERS ARE CONSIDERED APPROVED BY THE NEC AND ACCEPTABLE TO THE AHJ CLG CEILING J - > Q THERMAL DETECTOR (CEILING MTD.) X SUBSTITUTIONS. CONTRACTOR PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW W1TH C/B CIRCUIT BREAKERT L A COMPLETED SUBSTITUTION REQUEST FORM. OBTAIN THIS FORM AT WWW.GANDWENGINEERING.COM/DOCUMENTS.APPROVALS 21. PROVIDE EMT CONDUIT FOR INTERIOR WIRING WHERE PHYSICAL DAMAGE IS NOT A CONSIDERATION. MINIMUM CONDUIT SIZE IS V VOICE OUTLET BOX ^ p.. 00 " � a �a.. i CCTV CLOSED CIRCUIT TELEVISION ` �,, o v OF SUBSTITUTIONS ARE CONTINGENT UPON ENGINEER'S REVIEW. THE ELECTRICAL CONTRACTOR SHALL MAKE NO PRIOR 3/4" EXCEPT FOR FLEXIBLE CONDUIT TO FIXTURES, MOTORS, EQUIPMENT, ETC.,WHICH MAY BE 1/2". CONDUIT SHALL BE COND CONDUCTOR ♦ DATA OUTLET BOX 0 CARBON MONOXIDE DETECTOR Z Q w ASSUMPTIONS ON SUBSTITUTIONS NOT APPROVED BY THE ENGINEER. IF THE ENGINEER APPROVES A SUBSTITUTION REQUEST, CONCEALED WHEREVER POSSIBLE AND SHALL BE RUN PARALLEL OR PERPENDICULAR TO BUILDING WALLS, CEILINGS AND C CONDUIT(SEE RACEWAYS AND CONDUCTORS) ■ v THE ELECTRICAL CONTRACTOR WILL BE HELD RESPONSIBLE FOR ENGINEERING REVISIONS, PHYSICAL SIZE, CAPACITIES, STRUCTURE. EMT CONDUIT MAY BE USED FOR PANEL FEEDERS ABOVE THE FLOOR UNLESS OTHERWISE NOTED. HWC OR GRSCP CONTROL PANEL O VOICE/DATA OUTLET BOX ®ss SMOKE DETECTOR WITH SOUNDER BASE s COORDINATION, SUPPLEMENTAL DRAWINGS AND INFORMING OTHER TRADE CONTRACTORS AS TO ANY SPECIFIED ITEM CHANGES SHALL BE USED FOR CONDUIT EXPOSED TO WEATHER. "SEAL-TIGHT" RACEWAY SYSTEMS SHALL BE USED FOR EXTERIOR CU COPPER ® POWER POLE. SEE PLANS. F SUPPLY AIR SMOKE DETECTOR PROFF RELATED TO THE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL BEAR AS PART OF THEIR CONTRACT,ANY ADDITIONAL CONNECTIONS AT EQUIPMENT SUBJECT TO VIBRATION, 36"MAXIMUM IN LENGTH.ALL OUTLET, SPLICE, PULL,AND DEVICE BOXES CUH CABINET UNIT HEATER Osa 7'i._0 NGLN E `ss, COSTS INCURRED IN THEIR WORK, OR BY THE OTHER CONTRACTORS, ASA RESULT OF THE INSTALLATION FOR OTHER THAN"BASIS SHALL BE PROVIDED TO COMPLY WITH THE NEC FILL REQUIREMENTS. THE MINIMUM CONCEALED SIZE ELECTRICAL BOX ISA CT CURRENT TRANSFORMER El JUNCTION BOX-WALL MTD. o-_RETURN AIR SMOKE DETECTOR w/ t9 y OF DESIGN"MATERIALS AND EQUIPMENT. METALLIC 4"X4"X2"WITH THE REQUIRED FLUSH FRAME FOR ANY POWER OR LOW VOLTAGE DEVICE-NO EXCEPTIONS. DC DIRECT CURRENT RA SAMPLING TUBE 2 7°..:53 PE pr DOC DIRECT DIGITAL CONTROL Q JUNCTION BOX-CEILING MTD. 0 R.T.U./A.H.U. SHUTDOWN RELAY ' 5. SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY AS PDF FILES. SHOP DRAWINGS SHALL INCLUDE TRANSMITTAL PAGE(S) 22. PROVIDE STRUCTURAL STEEL FRAMEWORK, STRUT SYSTEMS,THREADED HANGING RODS, BRACES,AND ACCESSORIES WHERE sR DISC DISCONNECT INDICATING THE NAME OF THE PROJECT,AND THE NAME.ADDRESS, AND PHONE NUMBER OF THE GENERAL AND ELECTRICAL REQUIRED TO HOLD EQUIPMENT IN FINAL POSITION. PROVIDE STEEL SHAPES AND FRAMES TO SUPPORT WALL MOUNTED DN DOWN 0 MODULAR FURNITURE WHIP- POWER F R.A. DUCT MTD. SMOKE DETECTOR REMOTE TEST i, CONTRACTORS. GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR SHALL REVIEW SHOP DRAWING SUBMITTALS FOR EQUIPMENT WHERE NORMAL WALL STRENGTH MAY BE INADEQUATE_ ELECTRICAL DEVICES, MOTOR STARTERS: DISCONNECT ORTs STATION WITH KEY LOCK t% COMPLIANCE, CONTENT AND COMPLETENESS AND PROVIDE A STAMP WITH THE DATE OF REVIEW AND SIGNATURE OF THE SWITCHES, ETC., SHALL BE SUPPORTED INDEPENDENT OF AND ISOLATED FROM EQUIPMENT VIBRATION. DR DUPLEX RECEPTACLE 1111MODULAR FURNITURE WHIP-VOICE/DATA 1 E EMERGENCY QQ DOOR HOLDER i 8,200 REVIEWER. TRANSMITTAL PAGE SHALL HAVE INDEX WITH SPECIFICATION SECTION AND DESCRIPTION OF SUBMITTED ITEMS. NO off (E) EXISTING (+XX") MOUNTING HEIGHT TO CENTERLINE - ES EXCEPTIONS WILL BE TAKEN. SHOP DRAWINGS NOT SUBMITTED IN THIS FORMAT WILL BE REJECTED AND WILL NOT CAUSE REASON 23. PROVIDE LIGHT FIXTURES AS LISTED ON LIGHTING FIXTURE SCHEDULE. PROVIDE NECESSARY MOUNTING HARDWARE FOR AF�� EBB ELECTRIC BASE BOARD O CONTROL MODULE FOR PROJECT DELAYS. EQUIPMENT SHALL NOT BE ORDERED UNTIL ENGINEER OF RECORD HAS PROCESSED APPLICABLE SHOP COMPLETE INSTALLATION. ASSEMBLE ALL LIGHT FIXTURES SHIPPED TO THE PROJECT SITE. PROVIDE LAMPS, BALLASTS.AND cM h./1_7 1 71,11q DRAWINGS.A MINIMUM OF SEVEN WORKING DAYS WILL BE ALLOWED FOR SUBMITTAL PROCESSING BY THE ENGINEER. NOTED SPECIAL CONTROLS. PROVIDE A NEUTRAL AND GROUND WIRE AT EACH TOGGLE SWITCH ROUGH-IN.ALL LIGHTING EC ELECTRICAL WORK CONTRACTOR SWITCHES iiV SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: LIGHT FIXTURES, LIGHTING CONTROLS(OCCUPANCY SENSORS), FLOOR BOXES. FIXTURES SHALL BE PROVIDED WITH CODE APPROVED MEANS OF SUPPORT EF EXHAUST FAN 0 M MONITOR MODULE EOL END LINE RESISTOR $x SINGLE POLE SWITCH(+42") 6. ELECTRICAL WORK SHALL BE PROVIDED TO COMPLY WITH NFPA 70, THE 2014 OREGON ELECTRICAL SPECIALTY CODE, AS WELL AS 24. ELECTRICAL CONTRACTOR SHALL CUT AND PATCH ROOF, FLOORS,WALLS,AND CEILINGS WHERE REQUIRED TO INSTALL NEW EMS ENERGY MANAGEMENT SYSTEM 3 OF, FLOW SWITCH ALL APPLICABLE LOCAL ORDINANCES, STATE LAWS AND FEDERAL LAWS. ELECTRICAL BOXES, FIXTURES,AND RACEWAY SYSTEMS. SURFACES SHALL BE PATCHED AND LEFT READY FOR FINAL SCHEDULED EMT ELECTRICAL METALLIC TUBING $ 3-WAY SWITCH (+42') Z EUH ELECTRIC UNIT HEATER ,, PRESSURE SWITCH ® O FINISH. ROOFING WORK SHALL BE PERFORMED BY A QUALIFIED ROOFING CONTRACTOR THAT MAINTAINS THE ROOF WARRANTY. Ps EWC ELECTRIC WATER COOLER $ 4-WAY SWITCH (+42") � 7. SUBMIT AND PAY FOR ALL REQUIRED WORK PERMITS. PROVIDE ALL REQUIRED INSPECTIONS AND RE-INSPECTIONS. PROVIDE A ALL REQUIRED ROOFING WORK DUE TO ELECTRICAL SCOPE OF WORK SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BID. SUPERVISORY VALVE Q N g CERTIFICATE OF INSPECTION AT THE PROJECT COMPLETION. EWH ELECTRIC WATER HEATER $ SWITCH WITH PILOT LIGHT sv z O 25. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT OCCURRING IN EXIST EXISTING G C SUBSCRIPT- DENOTES CEILING MOUNTED Q0 8. ALL ITEMS OF WORK, EQUIPMENT AND MATERIALS SHALL BE SPECIFICALLY INSTALLED PER WRITTEN INSTALLATION INSTRUCTIONS DEMOLISHED WALLS, FLOORS, ATTICS, CEILING CAVITIES,THE ROOF AND AS OTHERWISE DESCRIBED HEREIN AND AS SHOWN ON F FLUORESCENT $O COMB. SWITCH/DUPLEX RECEPTACLE W2 AND METHODS OF INSTALLATION AS PUBLISHED BY THE MANUFACTURER OF THE EQUIPMENT OR MATERIAL PROVIDER. THE DRAWINGS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE COMPLETE SCOPE OF DEMOLITION. ELECTRICAL FA FIRE ALARM o . F.A.A.P. FIRE ALARM ANNUCIATOR PANEL E E4 ELECTRICAL CONTRACTOR SHALL UNDERSTAND THE PRODUCT, MEANS AND METHODS OF INSTALLATION. THE ELECTRICAL COMPONENTS INCLUDING MOTORS, TEMPERATURE CONTROL DEVICES, LIGHT FIXTURES, PIPING, FITTINGS, CONDUIT,WIRE, FAAP FIRE ALARM ANNUNCIATOR PANEL $ THERMAL OVERLOAD SWITCHImo CONTRACTOR SHALL OBTAIN THE INSTALLATION INSTRUCTIONS AND REQUIREMENTS PRIOR TO BID.ALL RFI AND CLARIFICATIONS HANGERS, BRACKETS, INSULATION, ETC., NOT TO BE RETAINED BY THE OWNER OR TENANT, MUST BE REMOVED FROM THE FACP FIRE ALARM CONTROL PANEL M xZ MANUAL MOTOR SWITCH F.A.C.P. FIRE ALARM CONTROL PANEL OF SCOPE PRESENTED DURING CONSTRUCTION WHERE THE CONTRACTOR HAS NOT PREVIOUSLY OBTAINED THIS INFORMATION PREMISES AND BE LEGALLY DISPOSED OF BY THE ELECTRICAL CONTRACTOR.ALL LOOSE ENDS OF SYSTEMS WHERE SUCH FCU FAN COIL UNIT J FOR BIDDING PURPOSES WILL NOT BE CAUSE FOR ADDITIONAL COSTS OR PROJECT DELAY. ABANDONMENT HAS TERMINATED SHALL BE TRIMMED CLEAR AND APPROPRIATELY CAPPED OR SEALED IN A SAFE AND SECURE FDR FEEDER LOW-VOLTAGE SWITCH LIU MANNER. REMOVAL AND DEMOLITION SHALL BE BY THE RESPECTIVE OR APPROPRIATE TRADES MAINTAIN BRANCH CIRCUIT FPC FIRE PROTECTION CONTRACTOR $ SECURITY SYM BOL LIST U 9. PROVIDE EQUIPMENT GROUNDING SYSTEMS IN ACCORDANCE WITH THE NEC. THE CONDUIT SYSTEM SHALL FORM A CONTINUOUS CONTINUITY TO ADJOINING AREAS AS NEEDED. THIS INCLUDES, BUT IS NOT LIMITED TO, REMOVAL, MODIFICATION AND FSD FIRE/SMOKE DAMPER K$ KEYED SINGLE POLE SWITCH (+42") PATH FOR GROUND AND SHALL BE SAFETY GROUNDED AT THE DISTRIBUTION AND BRANCH CIRCUIT PANELS. PROVIDE REINSTALLATION OF EQUIPMENT AS NEEDED TO SUSTAIN THE EXISTING WORKING CONDITION OF ALL ELECTRICAL EQUIPMENT FSC FOOD SERVICE CONSULTANT SECURITY i GROUNDING CONDUCTORS WHERE INDICATED. PROVIDE A NEUTRAL AND GROUND WIRE AT EACH TOGGLE SWITCH ROUGH-IN. AND TO RETURN THESE AREAS TO FULL WORKING ORDER AT PROJECT COMPLETION. FTU FAN TERMINAL UNIT v$`? KEYED THREE-WAY SWITCH (+42") FV FIELD VERIFY "P WEATHERPROOF SWITCH iL CAMERA(BY OWNER) 10. ELECTRICAL CONTRACTOR SHALL PROVIDE FIELD COORDINATION WITH OTHER TRADES; SYSTEMS AS SHOWN ARE DIAGRAMMATIC 26. THIS ELECTRICAL CONTRACTOR SHALL CONFINE THEIR ACTIVITIES TO THE AREA SET ASIDE FOR THEM TO DO THEIR WORK AND GC GENERAL WORK CONTRACTOR $ �P Z AND GIVE THE GENERAL ARRANGEMENT AND LOCATIONS ONLY. ELECTRICAL CONTRACTOR SHALL COMPLETELY REVIEW THE SHALL NOT INTERFERE WITH ANY OF THE OWNER'S OR TENANT ACTIVITIES. THE ELECTRICAL CONTRACTOR WILL NOT BE GF GAS FURNACE 7 /e\ PANITILTIZOOM EXTERIOR CAMERAgl DISTURBANCEE ENTIRE SET OF CONSTRUCTION DRAWINGS FOR DETAILS OF CONSTRUCTION PRIOR TO STARTING WORK. ROUGH IN OF PERMITTED TO STORE MATERIAL EXCEPT WITHIN THE AREAS AS DIRECTED BY THE G.C. SHOULD ANY OF THE TIME SWITCH GFI GROUND FAULT INTERRUPTER ELECTRICAL FIXTURES, EQUIPMENT, CONDUIT, CABLES. ATTACHMENTS, AND HANGERS SHALL BE BASED ON THIS REVIEW. EXACT EXISTING INSTALLATION BE NECESSARY, THE ELECTRICAL CONTRACTOR SHALL SO INFORM THE OWNER WELL IN ADVANCE OF THE GRD GROUND ® MOTION DETECTOR SWITCH � WEATHERPROOF CAMERA LOCATIONS AND FINAL LAYOUT SHALL BE DETERMINED IN THE FIELD. PROVIDE ALL NECESSARY EQUIPMENT, FITTINGS, HANGERS. TIME CONTEMPLATED FOR THE DISTURBANCE. AFTER A PLAN ACCEPTABLE TO THE OWNER OR TENANT HAS BEEN FORMULATED GRS GALVANIZED RIGID STEEL CONDUIT BOXES, SUPPORTS. OFFSETS AND ACCESS PANELS REQUIRED FOR A COMPLETE INSTALLATION IN ALL RESPECTS. THE ELECTRICAL AND AGREED TO IN WRITING BY ALL PARTIES, THE G.C. SHALL KEEP IN CLOSE PERSONAL CONTACT WITH THE WORK TO SEE THAT GWH GAS WATER HEATER DIMMER SWITCH CEILING MOUNTED CAMERA CONTRACTOR'S MEANS AND METHODS OF INSTALLATION SHALL PROVIDE FOR OPERATING EFFICIENCY, NEATNESS OF IT IS EXECUTED IN ACCORDANCE WITH THE AGREED-UPON PROCEDURE. HID HIGH INTENSITY DISCHARGE C> ALARM EQUIPMENT APPEARANCE, EASE OF MAINTENANCE,AND NEC COMPLIANCE. THE ELECTRICAL CONTRACTOR SHALL PREPARE DIMENSIONED FIXTURES FIELD ERECTION DRAWINGS, WHERE REQUIRED; FOR USE BY THE INSTALLERS,TO ENSURE PROPER INSTALLATION AND 27. CONTINUITY OF ALL BUILDING SERVICES AND UTILITIES SERVING FACILITIES IN THE BUILDING SHALL BE MAINTAINED WITHOUT HOA HAND-OFF-AUTO ALARM PUSH BUTTON HP HORSEPOWER 0 RECESSED DOWN LIGHTING FIXTURE O COORDINATION. THE ELECTRICAL CONTRACTOR SHALL TAKE THEIR OWN MEASUREMENTS AT THE BUILDING,AND BE RESPONSIBLE INTERRUPTION, EXCEPT FOR SUCH A PERIOD OF TIME DESIGNATED BY THE GENERAL CONTRACTOR. THE ELECTRICAL HPS HIGH PRESSURE SODIUM FOR THE CORRECT LAYOUT, INTERPRETATION,AND USE OF ALL SIZES AND DIMENSIONS. KEEP"AS-BUILT" INFORMATION DURING CONTRACTOR SHALL SO ARRANGE AND EXECUTE THEIR WORK SUCH THAT ANY CONNECTIONS, EITHER TEMPORARY OR Q+ WALL MOUNTED LIGHT FIXTURE CARD ACCESS CONSTRUCTION AND FURNISH TO THE OWNER OR TENANT A RECORD SET OF LEGIBLE BLACK LINE PRINTS AND AN ELECTRONIC PERMANENT, OR REARRANGEMENT OF PRESENT EQUIPMENT,CONDUIT, WIRING. ETC.. SHALL BE IN SUCH A MANNER AS TO HWC HEAVY WALL RIGID CONDUIT COPY OF THESE DOCUMENTS AT THE PROJECT COMPLETION. ASSURE FULL RESUMPTION OF SERVICE AT THE TIME DESIGNATED BY THE GENERAL CONTRACTOR. IF TEMPORARY CROSS HWRCP HOT WATER RETURN CIRCULATING PUMP PENDANT LIGHT FIXTURE CE CAMERA EQUIPMENT CONNECTIONS, CONDUIT,WIRING, SWITCHES ETC.,ARE NECESSARY TO ASSURE THIS CONTINUITY OF THE BUILDING SERVICE,THE HZ HERTZ 11. REVIEW ARCHITECTURAL DRAWINGS FOR ALL FIRE RATINGS AND FIRE RATED ASSEMBLIES PRIOR TO BIDDING THE PROJECT. ELECTRICAL CONTRACTOR SHALL PROVIDE THEM TO THE GENERAL CONTRACTOR AT NO ADDITIONAL COST_ WHERE USED IN IG ISOLATED GROUND WALL WASHER LIGHT FIXTURE O CARD SWIPE ENTRY PROVIDE FIRE STOP AT EACH RATED WALL, FLOOR.AND CEILING-ROOF ASSEMBLY PENETRATION_ FIRE STOP SYSTEMS SHALL BE THESE DOCUMENTS, MAINTAIN IS DEFINED AS FOLLOWS: SUSTAIN THE EXISTING WORKING CONDITION OF ELECTRICAL DEVICES IMC INTERMEDIATE METALLIC CONDUIT DOOR CONTACT MANUFACTURED BY"3M". PROVIDE IN STRICT COMPLIANCE WITH THE MANUFACTURER'S APPLICATION DETAILS AND AND EQUIPMENT,WHICH INCLUDES, BUT IS NOT LIMITED TO, REVISING, REMOVING AND REINSTALLING TO PERFORM THE NEW JB JUNCTION BOX f r T 2x2/2x4 LIGHT FIXTURE INSTRUCTIONS. PROVIDE TAGGED CERTIFICATIONS AT EACH PENETRATION. PROVIDE SHOP DRAWINGS FOR REVIEW WITH THE U.L. WORK INDICATED. kVAR KILOVAR(S) DP DOOR STRIKE POWER SUPPLY LISTING AND TEST CRITERIA. PROVIDE FIRE STOPPING WHERE REQUIRED BY THE AHJ EQUAL SYSTEMS AS MANUFACTURED BY kVA KILOVOLT AMPERE(S) 11 • LIGHT FIXTURE WITH BATTERY "SPEC SEAL"OR"HILTI"WILL BE ACCEPTABLE. . 28. THE LANDLORD'S CONSTRUCTION CRITERIA, LEASE AGREEMENT,AND CONSTRUCTION STANDARDS ARE HEREIN MADE PART OF KW KILOWATT(S) 6 EXIT SIGN WITH FACES&ARROWS 11: DIGITAL VIDEO RECORDER THIS CONTRACT.ALL REQUIREMENTS IN THE LANDLORD'S CONSTRUCTION CRITERIA, LEASE AGREEMENT.AND CONSTRUCTION LCP LIGHTING CONTROL PANEL ® 0 12. PROVIDE CONDUIT. CABLES.AND ELECTRICAL ASSEMBLY PENETRATIONS OF NON-RATED ASSEMBLIES WITH DRAFT STOPPING, OR STANDARDS REFERRED TO AS TENANT WORK AND DEFINED AS ELECTRICAL WORK. SHALL BE PROVIDED BY THE ELECTRICAL LC LIGHTING CONTACTORES ELECTRIC DOOR STRIKE 1=1. EMERGENCY EGRESS LIGHT W/BATTERY �, SMOKE BARRIER SEALANT SYSTEMS. THROUGH PENETRATION SEALANT SYSTEMS SHALL BE MANUFACTURED BY"3M". PROVIDE IN CONTRACTOR. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS AND COMPLETELY MAN MASTER ANTENNA TELEVISION KP KEYPAD ENTRY SOUND AND SIGNAL ; CIN STRICT COMPLIANCE WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. PROVIDE DRAFT STOPPING OR FAMILIARIZE THEMSELVES WITH THESE DOCUMENTS PRIOR TO BIDDING THIS PROJECT. SUBMISSION OFA BID ACKNOWLEDGES MAX MAXIMUM ZanrCNI SMOKE BARRIER SEALANTS TO MEET APPROVAL OF THE AHJ- EQUAL SYSTEMS AS MANUFACTURED BY"SPEC SEAL"OR"HILTI"WILL THE ELECTRICAL CONTRACTOR HAS COMPLIED WITH THIS REQUIREMENT OF THE CONTRACT. MC MECHANICAL WORK CONTRACTOR O MOTION DETECTOR0) BE ACCEPTABLE. MFC MICROPHONE Q CEILING SPEAKER W I~ �I MIN MINIMUM e MOTION DETECTOR MTD.ABOVE CEILINGEr. 1. LI.. 6 13. ELECTRICAL CONTRACTOR SHALL GUARANTEE WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE MCA MINIMUM CIRCUIT AMPERES 5 WALL MOUNTED SPEAKER WORKMANSHIP AND MATERIALS, USUAL WEAR EXPECTED,AND SHOULD ANY SUCH DEFECTS DEVELOP WITHIN A PERIOD OF ONE MCB MAIN CIRCUIT BREAKER O ALARM PAD YEAR AFTER ACCEPTANCE OF THE BUILDING BY THE OWNER OR TENANT, THE ELECTRICAL CONTRACTOR SHALL REPAIR AND/OR MCC MOTOR CONTROL CENTER 0 VOLUME CONTROLZ REPLACE ANY DEFECTIVE ITEMS,AND DAMAGE RESULTING FROM FAILURE OF THESE ITEMS,AT NO COST TO THE OWNER OR MAH MANHOLE ,� PB WIRED ALARM BUTTON TENANT. MH METAL HALIDE LeJ BELLIBUZZER W a G REQUEST-TO-EXIT MOTION SENSOR MLO MAIN LUGS ONLY CAN OUTLET0 3 14. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND LIGHTING FOR THE DURATION OF THE PROJECT.ALL MOCP MAXIMUM OVERCURRENT PROTECTION 0 STROBE LIGHT TEMPORARY LIGHTING AND POWER SHALL BE PROVIDED TO MEET OSHA STANDARDS. STATE LAW, LOCAL ORDINANCES AND AHJ FIRE ALARM CRITERIA MTD MOUNTED 0 INTERCOM OUTLET REQUIREMENTS. REMOVE ALL TEMPORARY POWER AND LIGHTING AT THE PROJECT COMPLETION. NC NORMALLY CLOSED Q MICROPHONE OUTLET ® REMOTE VIDEO MONITOR 1. DELEGATED DESIGN: DESIGN FIRE ALARM SYSTEM, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A NF NON FUSED ® WIRELESS PUSHBUTTON 15. PROVIDE POWER WIRING AND CONNECTIONS FOR EACH HVAC EQUIPMENT ITEM. COORDINATE POWER REQUIREMENTS AND QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED. THE NIC NOT IN CONTRACT ROUGH-IN WITH THE EQUIPMENT SUPPLIER OR CONTRACTOR PRIOR TO STARTING CONSTRUCTION AND ORDERING ELECTRICAL DEVICE LAYOUT INDICATED ON THE PLANS SHALL BE CONSIDERED AS THE MINIMUM FOR THE BASIS OF DESIGN. NL NIGHT LIGHT SERVICE AND EQUIPMENT EQUIPMENT. OBTAIN A COPY OF EQUIPMENT SUPPLIER INSTALLATION DRAWINGS PRIOR TO SUBMITTING A BID. CONNECT ALL NOEQUIPMENT COMPLETE AND READY FOR OPERATION. 2. AN EXISTING FIRE ALARM SYSTEM IS PRESENT IN THIS BUILDING. ELECTRICAL CONTRACTOR AND FIRE ALARM OB OUTLETNORMABOXY OPEN ® RELAY 16. ELECTRICAL CONTRACTOR SHALL PROVIDE SAFETY DISCONNECT SWITCHES WHERE REQUIRED BY THE NEC AND AS SHOWN ON EQUIPMENT SUPPLIER SHALL VISIT THE SITE AND VERIFY ALL DETAILS OF THE SYSTEM WITH THE PROPERTY OB OUTLET THE DRAWINGS. SAFETY DISCONNECT SWITCHES SHALL BE"GENERAL DUTY"TYPE IN NEMA 1 ENCLOSURE. EQUIPMENT AS MANAGEMENT PRIOR TO THE BID. THIS WORK INCLUDES BUT IS NOT LIMITED TO PROVIDING NEW AUDIBLENISUAL P POLE N/F DISCONNECT SWITCH PC PLUMBING WORK CONTRACTOR CV MANUFACTURED BY SQUARE D, SIEMENS, GENERAL ELECTRIC OR CUTLER HAMMER IS ACCEPTABLE. SWITCHES SHALL BE SIGNAL DEVICES. SUPPLY EXPANDER, DETECTION DEVICES. CONTROL DEVICES, CABLES, CONDUCTORS, BRANCH LQQ FUSED DISCONNECT SWITCH CNI QUICK-MAKE, QUICK-BREAK, EXTERNALLY OPERATED AND INTERLOCKED WITH PROVISIONS FOR LOCK-OUT. PROVIDE NEMA 3R CIRCUIT POWER AND PROGRAMMING FORA FULLY FUNCTIONING AND COMPLIANT FIRE ALARM SYSTEM FOR THIS PF POWER FACTOR ENCLOSURES FOR ALL SWITCHES IN EXTERIOR LOCATIONS. PROVIDE DUAL-ELEMENT TIME DELAY FUSES SUITABLE FOR TENANT. MEET ALL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION_ PROVIDE A FIRE ALARM/INSPECTION PRIPH PHASE PRIMARY ® STARTER APPLICATION AND LOAD SERVED WHERE INDICATED. 277/480 VOLT SYSTEMS REQUIRE"HEAVY DUTY"TYPE SAFETY DISCONNECTS PERMIT TO BE PROVIDED. PT POTENTIAL TRANSFORMER LEE COMBINATION STARTER/DISC. SW. 3. PROVIDE FIRE ALARM AUDIBLE AND VISUAL SIGNALS COMPLIANT WITH THE STATE OF OREGON DISABILITY PVC POLYVINYL CHLORIDE STANDARDS-NO EXCEPTIONS. WHERE TWO OR MORE VISIBLE NOTIFICATION APPLIANCES ARE IN THE SAME FIELD OF REC RECEPTACLE Q PUSHBUTTON OR CONTROL STATION VIEW, THEY MUST FLASH IN SYNCHRONIZATION. PROVIDE RELAY MODULES TO ACTIVATE EXPANDER MODULE FOR RF RETURN FAN © PHOTOCONTROL SIGNALS. PROVIDE OR RELOCATE AN EXISTING SMOKE DETECTOR TO THE AREA THE SUPPLY EXPANDER WILL BE RL EXISTING DEVICE RELOCATED INSTALLED. MAINTAIN UL LISTING OF EXISTING SYSTEM. PROVIDE RELAY MODULES TO SHUTDOWN EACH FAN RT RAIN TIGHT(NEMA 3R) a MOTOR TERMINAL SUPPLY FAN IN THE TENANT AREA. PROGRAMMING FOR CONTROL FUNCTIONS OPERATION SEQUENCE RTU ROOF TOP UNIT SHALL BE COORDINATED WITH THE BUILDING ENGINEER AND THE AUTHORITY HAVING JURISDICTION. SEC SECONDARY ® ENCLOSED CIRCUIT BREAKER SD SMOKE DAMPER 4. PROVIDE ALL SIGNAL AND LOOP WIRING REQUIRED TO REVISE THE EXISTING FIRE ALARM SYSTEM. COORDINATE SF SUPPLY FAN ® MAIN DISTRIBUTION PANEL I" WITH F.A. EQUIPMENT SUPPLIER. ALL CABLING SHALL BE PLENUM RATED.ATTACHED AND INSTALLED IN STRICT SW SWITCH ACCORDANCE WITH NFPA 72, LOCAL BUILDING CODE AND AUTHORITY HAVING JURISDICTION. SWBD SWITCHBOARD (_ I BRANCH CIRCUIT PANELBOARD W W T TELEPHONE 5. PROVIDE PROGRAMMING AND ASSISTANCE FOR TESTING PRIOR TO OCCUPANCY. PROVIDE ALL LABOR TO COMPLETE TC TIMECLOCK ® SEE MECHANICAL© MECHANICAL NICAL EQUIPMENT DRAWINGS.IPMENT PLAN MARK I OD THE FIRE ALARM SYSTEM INSTALLATION, PROGRAMMING AND TESTING IN ACCORDANCE WITH NFPA 72 TO ACHIEVE TEB TELEPHONE EQUIPMENT BOARD /� AN OCCUPANCY PERMIT_ PROVIDE A CERTIFICATE OF INSPECTION FOR THE TENANT. SEND THE ENGINEER THE FINAL TEF TOILET EXHAUST FAN On 1 c X, PLAN NOTE SYMBOL W X TEST CERTIFICATE OR APPROVED BY THE AUTHORITY HAVING JURISDICTION AT PROJECT COMPLETION, NO TEMP TEMPORARY u EXCEPTION. E-MAIL: SLOHER@GANDWENGINEERING.COM TV TELEVISION REVISION SYMBOL TVSS TRANSIENT VOLTAGE SURGE SYMBOL 6. PROVIDE SHOP DRAWING SUBMITTALS FOR REVIEW BY ENGINEER AND PERMIT PLAN REVIEWER. SUBMITTAL SHALL TYP TYPICAL CIRCUITRY AND RACEWAYS INCLUDE BUT NOT BE LIMITED TO HARDWARE CUT SHEETS.WIRING DIAGRAMS, BATTERY CALCULATIONS AND UH UNIT HEATER VOLTAGE DROP CALCULATIONS. PROVIDE ENGINEER SEALED SUBMITTALS WHERE REQUIRED BY THE AUTHORITY UNV UNIVERSAL CONCEALED CONDUIT(2#12 AWG&APPROVED Q HAVING JURISDICTION. UON UNLESS OTHERWISE NOTED 1 GROUND MINIMUM-TYP.) 7. SYSTEM DETECTORS SHALL BE PROTECTED FROM DUST DURING CONSTRUCTION AND CLEANED AFTER V VOLT(S) 2- - -2 CONDUIT BELOW FLOOR OR GRADE 0 CONSTRUCTION. VA VOLTAMP(S) VAV VARIABLE AIR VOLUME r---2 CONDUIT EXPOSED VFD VARIABLE FREQUENCY DRIVE F 8. SEE ELECTRICAL CRITERIA FOR ADDITIONAL REQUIREMENTS. VOIP VOICE OVER IP w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rg N -, O Mg , F- cC o n 0 a Ce rin' 8 Z - 2'�" - Z m cC M O F- c' Z W Z z wz7 • c o! i i��i - Q LU Liu ad 2 G Z Lr h-u < w j(1 X mix 0 Z_ c ■ § U O n i t V IF7„, I i= • ), w Z 0 r FIXTURES DESIGNATED AS - {f'� +� d n u� NOTES: ( �' "NL"SHALL BE UNSWITCHED. Q z �i 143 d \ [inl 0 bd 0 n n 1. CENTERLINE OF POWER AND VOICE/DATA FEED NOT TO EXCEED 24" FROM CENTERLINEE9 IlD °4 °C OF PANEL SPINE(X), TYPICAL. —� 0 2 V co r HOTZ • U °:°: 2. PROVIDE A STAINLESS STEEL COVER PLATE WITH A 314"90°WHIP INSTALLATION. FOR A o WALL SWITCH AC BALLAST/DRIVER 4 J j ONE(1)CIRCUIT HOMERUN, WIRE LINES 1, 2 AND 3 TOGETHER. FOR A TWO(2)CIRCUIT v v OR RELAY I E 40 2 ° .__ xQ o HOMERUN,WIRE LINES 1 AND 2 TOGETHER AND 3 SEPARATE. FOR A THREE(3)CIRCUIT ( !! CONTACT �] HOMERUN.WIRE LINES 1. 2 AND 3 SEPARATE. WHIPS WILL BE PROVIDED BY TENANT. . . i L.w o v Q om- b 3. PROVIDE A FLUSH 4x4 BOX AND BLANK STAINLESS STEEL FACE PLATE WITH 3/4"HOLES NOTE: RECEPTACLES AND PHONE/DATA JACK WILL BE EMERGENCY BALLAST/DRIVER Z ■ s PUNCHED AS REQUIRED FOR DATA WHIPS. DATA WHIPS AND FITTINGS WILL BE PROVIDED AND INSTALLED BY TENANT'S FURNITURE EQUIPMENT2 _ PROVIDED BY TENANT'S DATA SYSTEMS CONTRACTOR. SUPPLIER UNLESS LOCAL CODE REQUIRES THAT THE EC COMMON I (,,,,0 ' 01NEEAS'/02CONNECT WHIPS AND INSTALL THE RECEPTACLES. NOTE: COORDINATE FINAL RECEPTACLE LOCATION WITH 9FURNITURE VENDOR. 7..33PE- 0 WHIP INSTALLATION TYPICAL AI CUBICLE OUTLET TYPICAL © DIRECTOR OFFICE OUTLET TYPICAL 0 EMERGENCY LIGHT WIRING DIAGRAM E-101 112"= 1'-0" E-101 114"= 1'-0" E-101 1/4"= 1'-0" E-101 NO SCALE :� % 1.1 !LCC t4248.2Qo_$ GENERAL NOTEIlik .. �� GENERAL CONTRACTOR TO PROVIDE SUB-CONTRACTOR NAME,ADDRESS,AND MAY 2 3 2018 CONTACT INFORMATION TO PROJECT MANAGER FOR DELIVERY OF TENANT PROVIDED FURNITURE WHIPS. W C i ® O PROVIDE 314" LIQUID ILI, g TIGHT CONDUIT ADAPTOR Z a O FOR POWER WHIP / 1-4 CUBICLES PROVIDE // 314"TRADEADAPTOR SIZEFORDATAICOCONDUITMM. drillia, 5-12 CUBICLES PROVIDE Nu/ 1-1/4"TRADE SIZE CONDUIT �i ADAPTOR FOR DATA/COMM. Z W U6 .., 0 ...„..,!.;..,:, , WIREMOLD MODEL#4FFATC15BK WITH ONE 3/4"TRADE SIZE CONDUIT PLUG AND ONE 1-114'TRADE SIZE CONDUIT PLUG. NOTE LONG RADIUS ELBOW PRIOR TO SUBMITTING THIS PRODUCT FOR - BUSHING REVIEW, THE CONTRACTOR SHALL SITE VERIFY THAT THE SPACE BELOW HAS AN ACCESSIBLE (LAY-IN)CEILING AND WILL NOT POKE INTO A PROHIBITED SPACE SUCH AS AN PULL STRING • ELEVATOR MACHINE ROOM, VAULT, STAIR. ELECTRICAL ROOM, MECHANICAL ROOM OR HILT! CC27 CLIP(OR EQUAL) STRUCTURE II 0 SIMILAR ROOM. o f jr 1 9 CEILING #12 GA. SAFETY WIRE TIED TO SAFETY WIRE SUPPORT HOLES& FASTENED �\ D TO BLDG- STRUCTURE. MINIMUM (1) I 'I SAFETY WIRE AT CENTER OF FIXTURE DRYWALL OR FINISH SURFACE FOR LIGHT FIXTURES LESS THAN 10 .A7''''' 'l LBS- MINIMUM (2)SAFETY WIRES e ZO PLACED AT DIAGONAL CORNERS FOR "// ��... PHONE/DATA CONDUIT SIZE CHART / III-tip (+►� LIGHT FIXTURES WEIGHING 10 LBS. OR �� / CZ N #OF CONDUIT DROP MORE BUT LESS THAN 56 LBS. / •������ / N ■uI 111% f CARPET OR TILE WORKSTATIONS SIZE Gx� \. Z TRIM FLANGE FOR PRIVATE OFFICE 1" �\ O CARPET OR TILE o ANGLE OR FLAT STRAP TO 1-4 (1)_1't 1 ,e 6 ! a 1 �� / STUD 5-12 (2)_1„ LIGHT FIXTURE d �/ SAFETY WIRE ‹..--<, . . o. 4"CORE DRILL PER MANUFACTURER O CONFERENCE ROOM 1" v SUPPORT HOLE, Z SCRUB WATER 4 . r . + . r • COORDINATE EXACT LOCATION WITH _ COPIER 1" GASKET S ° TENANT BEFORE DRILLING. o o III TYPICAL 0%. i. > • n a III SINGLE GANG FLUSH FRAME U O N W a F A ° CONCRETE SLAB / O PROVIDE BLANK STAINLESS STEEL PLATE SEISMIC RESTRAINT CLIP a c0 S f 0 o III WITH HOLES PUNCHED AS REQUIRED FOR ALL POWER WHIPS ARE 3/4" U.N.O. MINIMUM(4) PER LIGHT SWAY BRACED GRID CEILING RETAINING FLANGE I INTUMESCENT MATERIAL III FURNITURE WHIPS OR TENANT WILL FIXTURE. SECURELY AND 111 2-HOUR RATING O� INSTALL DATA/PHONE DEVICE AND COVER_ EMPTY CONDUITS SHALL BE PROVIDED POSITIVELY ATTACHED TO IF NOT USED FOR A WHIP OR DEVICE, WITH PULL STRING CEILING GRID,TYPICAL PROVIDE BLANK COVER PLATES MATCHING 3/4"TRADE 1-1/4"TRADE SIZE EMT DEVICE FACE PLATES. SIZE EMT CONDUIT _ CONDUIT FOR DATA/COMM. PHONE/DATA WHIP SIZE CHART FOR POWER 1'_6" NOTES: EXTEND CONDUIT WITH #OF LIQUID-TITS 1 SUPPORT WIRES FOR FIXTURES WEIGHING LESS THAN 56 LBS MAY BE INSTALLED SLACK. ALL OTHER SUPPORT PULL STRING TO (U.(').N.) 4"W x 4"H x 2-1/8"DEEP WORKSTATIONS WHIP SIZE WIRES SHALL BE INSTALLED TAUT WITH A MINIMUM OF 3 TIGHT TURNS AROUND ITSELF ACCESSIBLE CEILING 4.. NOTE: A SECTION OF FLEXIBLE WHERE INDICATED ON PLAN. 1-4 (1)314" CONDUIT MAY BE USED TO ALLOW STUD FRAMING BY 5-8 (2)3/4" 2. LIGHT FIXTURES WEIGHING 56 LBS. OR MORE SHALL BE INDEPENDENTLY SUPPORTED DIRECTLY FROM THE N FLOOR BOX TO BE PULLED OUT OF OTHERS STRUCTURE ABOVE, BY APPROVED HANGERS. 0 9-12 (2) 1" FLOOR. O JUNCTION BOX FLOOR ALL POWER WHIPS ARE 3/4" U.N.Q. EXCEPTION: /� LIGHT FIXTURES THAT ARE NOT COMPONENTS OF A STANDBY OR EMERGENCY LIGHTING SYSTEM AND WEIGH O LESS THAN 20 POUNDS AND ARE POWERED USING FLEXIBLE CABLE CONNECTIONS NOT LESS THAN 3 FT. LONG CONNECTED TO THE FIXTURES,ARE NOT REQUIRED TO HAVE THE ADDITIONAL SUPPORT WIRE(S)DESCRIBED NOTE: POWER WHIPS WILL BE PROVIDED BY TENANT FOR INSTALLATION BY E.C. ABOVE TENANT'S DATA SYSTEM CONTRACTOR WILL PROVIDE AND INSTALL DATA ABOVE. SUCH FIXTURES ARE REQUIRED TO BE POSITIVELY ATTACHED TO THE CEILING GRID AS DESCRIBED WHIPS. © FLUSH FURNITURE POKE THRU ROUGH-IN DETAIL 6 VOICE / DATA OUTLET DETAIL 7 RECESSED LIGHTING FIXTURE SUPPORT DETAIL E-101 NO SCALE E-101 NO SCALE E 101 NO SCALE CO W J D 121 NOTE: EQ. rr EQ ON COLUMN OR 1'-0" FROM WI PROVIDE INTERMEDIATE BLOCKING EDGE OF WALL FOR DEVICES AS REQUIRED FOR S„ 1,-0„ ' F A.VISUAL SIGNAL SPECIFICATION FOR LOCATION OF DEVICES 0 CO PLACEMENT AS DIMENSIONEDABLE ,u ;1 A. WHEN MOUNTING MULTIPLE DEVICES FROM DIFFERENT TRADES IN THE SAME LOCATION (SUCH AS LIGHTING J CO F.A. VISUAL SIGNAL WHERE APPLICABLE SWITCHES, THERMOSTATS, ETC ), THEIR ARRANGEMENT SHALL BE IN ACCORDANCE WITH THE FOLLOWING: I EDGE OF COLUMN OR WALL 1- LOCATE DEVICES AS SHOWN ON THE ARCHITECTURAL PLANS, ELEVATIONS OR SECTIONS. 0 < 2. WHEN SHOWN ON MECHANICAL OR ELECTRICAL DRAWINGS, BUT NOT ON ARCHITECTURAL DRAWINGS: DEVICES ""� THERMOSTAT WALL-MOUNTED TELEPHONE, I SHALL BE UNIFORMLY AND SYMMETRICALLY MOUNTED. VERTICALLY ALIGN DEVICES MOUNTED AT HEIGHTS OR AN DEVICE \ INDICATED, UNLESS SEPARATED HORIZONTALLY BY A MINIMUM OF 24". 0 \, 6 3. DEVICES INSTALLED IN MASONRY OR SURFACES TO RECEIVE WOOD PANELS,WALL COVERING OR SIMILAR 0 r MATERIALS SHALL BE INSPECTED BY THE ARCHITECT AT TIME OF ROUGH-IN. W ADDITIONAL DEVICES \ \ 4. IF THE CONTRACTOR HAS ANY DOUBTS REGARDING THE LOCATION OF DEVICES. HE SHOULD CONSULT WITH .J Z \\:\\ �'. f II • THERMOSTAT(TYP.) THE PROJECT ARCHITECT/ENGINEER PRIOR TO ROUGHING-IN. W Z WHERE MULTIPLE SWITCHES OCCUR, U a (IL/ 5 CONTRACTOR SHALL CONFIRM THE FINAL LOCATION OF MONITORS WITH THE TENANT PRIOR TO ROUGH-IN. GANG WITH SINGLE COVER PLATE — - \ \ AN SIGNALS SHALL BE A MINIMUM OF 36" HORIZONTALLY FROM ANY MONITOR. THEN LOCATE THE OTHER DEVICES L LIGHT SWITCH (TYP.) CENTERED OFF FURTHEST LIGHT SWITCH } B. DEVIATIONS FROM THE ABOVE PRINCIPLES WITHOUT PRIOR APPROVAL BY THE ARCHITECT/ENGINEER SHALL BE DATE 05/23/2018 a- CORRECTED BY THE INSTALLING CONTRACTOR.ANY COST, INCLUDING CUTTING& PATCHING, ENTAILED IN THE REMOVAL, SWITCH OR DIMMER H I-esH o } DUPLEX RECEPTACLE, RELOCATION,AND REINSTALLATION OF ANY DEVICES SHALL BE THE RESPONSIBILITY OF THAT CONTRACTOR. SCALE AS NOTED in f _Co , COMMUNICATION OUTLET, ETC. DOOR OR SIDE LITE FRAME �,) /v CO 4 �• (TYP.) ' MGR SRA `? JOB CEN014 . \ \ \ \ `, \ \ SHEET 0 CENTENE DEVICE LOCATION DIAGRAM E -1O1 E-101 NO SCALE OF SHEETS ■ IHDL DESIGN HEREB1 EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMI SIGN OF MDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I 0 REVISIONS BY i' C$ rd NZ `4 g 10 R h GCI. o ri LIGHTING FIXTURE SCHEDULE 1 Q ° o V ° z m PLAN MOUNTING MANUFACTURER MODEL NO. LAMPS INPUT FINISH NOTES O = `nZ Z W MARK WATTS U C7 r r� . W L.L.7 Z A C/R METALUX 22CZ-LD5-34-UNV-L840-CD1-U LED 3567 LUMENS 29.4 WHITE 1,2 04 Z Q O Q w r Ir AE C/R METALUX 22CZ-LD5-34-UNV-EL14W-L840-CD1-U LED 3567 LUMENS 29.4 WHITE 1,2,3 u < J B C/PP RESOLUTE PUNCHEON P59RM1SHADE:CARNEGIE XOREL-SPIRE 6269-12 E26 LED 1000 LUMEN 14 SILVER 1,2 Z G ] ■ nN O R1 C/R RELOCATED 2x4 18-CELL PARABOLIC FIXTURE 3-F32T8135K SILVER Z u Z 6 n v SM '� I- 6,/§) v_ R2 C/R RELOCATED 2x2 9-CELL PARABOLIC FIXTURE 3- F17T8135K SILVER W Q w a, V •�,++ L Q o0 00 � 1 a � � R3 CIR RELOCATED 2x2 DIRECT/INDIRECT FIXTURE LED 3567 LUMENS WHITE > v} Z n� C d (a o SECURITY SYSTEM ROUGH-IN ACS TYPE 60 SECURITY SYSTEM ROUGH-IN ACS TYPE 70 X UNIV. SURE CITES LPX7 INCLUDED - WHITE 1 Q �i 0 V/ - 1 n _ r r n n I- cv r r O I r T - 1 , NOTES, 1. ORDERING INFORMATION:THE ELECTRICAL CONTRACTOR SHALL REVIEW THE CONSTRUCTION DRAWINGS, BRANCH CIRCUIT VOLTAGE AND SUBMITTED D �, w up I I CEILING / I I 1 LIGHTING FIXTURE SHOP DRAWINGS- THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ORDERING THE CORRECT VOLTAGE FOR LIGHTING FIXTURES- U z of rn E I\I I © I I - 0 NO EXCEPTIONS- INCORRECTLY SUBMITTED SHOP DRAWINGS AND FIXTURE ORDERS WITH THE INCORRECT FIXTURE VOLTAGE WILL NOT BE CAUSE FOR J W > o CONSTRUCTION DELAYS OR ADDITIONAL COSTS. x I 12" I I I 12" 12 t7 0_ 2 \ I 2. NO SUBSTITUTIONS. Q o .0 /,3, e 3 0 3. EMERGENCY DRIVER MAY BE FIELD INSTALLED IF LIGHT FIXTURE LEAD TIME IS AN ISSUE t ��,Q :/`,0s, c,1 N E ER /02 ABBREVIATIONS- C/R CEILING RECESSED, W/S WALL SURFACE, CIS CEILING SURFACE, GIP GRADE PAD, UNIV. UNIVERSAL. �� C/CV CEILING COVE, C/P CEILING PENDANT, W/R WALL RECESSED, G/PL GRADE POLE U/C UNDER COUNTER, 79-,33P 1 C/AC CEILING AIR-CRAFT CABLE r 1 0 O 3 1 �4'. S.2 0 �1 • }- j-, MAY 23 24]3 / / 11 -� 6 6' 1 OCCUPANCY SENSOR LEGEND le 6 SYMBOL WATT STOPPER MOUNTING COLOR SENSOR COVERAGE AREA TYPICAL APPLICATIONS LL Li Li MODEL# TECHNOLOGY COVERAGE MINOR MOTION MAJOR MOTION Q Q (DESKTOP) (WALKING) Wm Q - DW-311 WALL SWITCH WHITE PIR& 180° 20'x15' 30'x30' FACTORY DEFAULT SET TO MANUAL ON CORRIDOR, MAIL ROOM, FILE ROOM, p x❑s D 120/277V +42"CENTER ULTRASONIC STORAGE ROOM, COPY ROOM, ELECTRICAL ROOM(MAJOR MOTION). 1.7 W M CONTINUOUS DIMMING CONTROLS FOR 1 LIGHTING LOAD. CO DW-100 WALL SWITCH MATCH PIR& 180' 15'x15' 20'x20' PRIVATE OFFICE, BREAK ROOM, CONFERENCE ROOM C, RECEPTION, TRAINING, NETWORK g \ FLOOR FLOOR X l 120/277V +42"CENTER WALL MTD ULTRASONIC ROOM OR PRIVATE RESTROOM (MINOR MOTION). COPY ROOM, MAIL ROOM, STORAGE Z DEVICES ROOM OR WORK ROOM(MAJOR MOTION). J W U 1. ELECTRIFIED CYLINDRICAL LOCK. 1_ ELECTRIFIED CYLINDRICAL LOCK. DT-200 CEILING/HIGH WHITE PIR& 90° 30' RADIUS 50' RADIUS BREAK ROOM, CONFERENCE ROOM A, CONFERENCE ROOM B, RECEPTION, TRAINING ROOM RWALL ULTRASONIC (SEATING MINOR, REMAINING MAJOR), MAIL ROOM, STORAGE ROOM, WORK ROOM(MAJOR ■.. 0 2. DOOR CONTACT POSITION: 1"DIAMETER ROUGH-IN HOLEDRILLED INTO FRAME 3" 2. DOOR CONTACT POSITION: TWO 1"DIAMETER ROUGH-IN HOLES DRILLED INTO FRAME MOTION): NETWORK ROOM (MINOR MOTION), FITNESS ROOM(MAJOR MOTION). FROM TOP CORNER AS SHOWN. 1"CONDUIT INSTALLED FLUSH WITH DOOR CONTACT 3"FROM TOP CORNER AS SHOWN. TWO 1"CONDUIT INSTALLED FLUSH WITH DOOR POSITION TO JUNCTION BOX ABOVE DOOR. CONTACT POSITIONS TO DOOR CONTACT SPLICE POINT, _,<)..._ DT-300 CEILING WHITE PIR& 360° 31'x31' 40'x40' OPEN OFFICE(MINOR MOTION, 20%OVERLAP) 3. BADGE READER POSITION: 1 FLUSH MOUNTED SINGLE GANG BOX INSTALLED ON 3. BADGE READER POSITION: 1 FLUSH MOUNTED SINGLE GANG BOX INSTALLED ON ULTRASONIC RESTROOM WIPARTITIONS(MINOR MOTION) LOCATE WITHIN 2'OF STALLS EXTERIOR SIDE WALL OF DOOR AT 44"AFF. 1"CONDUIT INSTALLED FROM BADGE READER EXTERIOR SIDE WALL OF DOOR AT 44"AFF. 1"CONDUIT INSTALLED FROM BADGE READER POSITION TO JUNCTION BOX ABOVE DOOR. POSITION WITH 2"STUB LEFT ABOVE CEILING FOR ACCESS. WT 2250 CEILING WHITE ULTRASONIC 360° 63'x8' 90'x10' CORRIDOR(MAJOR MOTION) 4. ELECTRIC TRANSFER HINGE/DOOR CORD POSITION: 1"CONDUIT INSTALLED FROM 4. MOTION REQUEST TO EXIT(REX)POSITION: 1 FLUSH MOUNTED SINGLE GANG BOX HINGE/CORD POSITION,THROUGH DOOR FRAME,TO JUNCTION BOX ABOVE DOOR. INSTALLED ON THE INTERIOR CEILING, FROM AND CENTERED 12"FROM DOOR. 1" CONDUIT WITH 2"STUB LEFT ABOVE CEILING FOR ACCESS_ 5. DOOR CHANNEL POSITION. MINIMUM 1/2"CHANNEL CORED THROUGH DOOR FROM BZ-150 JUNCTION BOX WHITE N/A N/A N/A N/A RELAY POWER PACK USED IN CONJUNCTION WITH SENSORS- REFER TO ELECTRIC HINGE/DOOR CORD POSITION TO DOOR STRIKE POSITION, 5. ELECTRIC TRANSFER HINGE/DOOR CORD POSITION: 1"CONDUIT INSTALLED FROM ® MANUFACTURER'S CUTSHEETS FOR MAXIMUM NUMBER OF SENSORS WIRED TO SINGLE Z HINGE/CORD POSITION,THROUGH DOOR FRAME,WITH 2"STUB LEFT ABOVE CEILING FOR POWER PACK. 6. MOTION REQUEST TO EXIT(REX)POSITION: 1 FLUSH MOUNTED SINGLE GANG BOX ACCESS. INSTALLED ON THE INTERIOR CEIL€NGIWALL ABOVE AND CENTERED 12"FROM DOOR. 1" EXISTING CEILING CONDUIT TO JUNCTION BOX ABOVE DOOR. 6. DOOR CHANNEL POSITION: MINIMUM 112"CHANNEL CORED THROUGH DOOR FROM O OCCUPANCY ELECTRIC HINGE/DOOR CORD POSITION TO DOOR STRIKE POSITION. SENSOR 7. JUNCTION BOX POSITION: (1)3"x3"JUNCTION BOX INSTALLED ABOVE CEILING NO MORE THAN 12"FROM DOOR. 7. EMERGENCY DOOR RELEASE POSITION: 1 FLUSH MOUNTED SINGLE GANG BOX NOTES: 1. COVERAGE AREA OF CEILING MOUNTED SENSORS ARE BASED ON 10'CEILING HEIGHT. INSTALLED ON EXTERIOR WALL,AT 44"AFF. 1"CONDUIT INSTALLED FROM DOOR RELEASE Q DETAIL REPRESENTS A TYPICAL ROUGH-IN/INSTALLATION FOR THIS SYSTEM DEVICE POSITION TO JUNCTION BOX ABOVE DOOR. 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND AIM SENSORS IN THE CORRECT LOCATION REQUIRED FOR COMPLETE AND PROPER § TYPE AND MAY NOT REPRESENT ACTUAL DOOR SWING OR WORK AREA BUILD. CONTACT VOLUMETRIC COVERAGE WITHIN THE RANGE OF COVERAGE(S)OF CONTROLLED AREAS PER THE MANUFACTURER'S RECOMMENDATIONS. THE LOCATIONS TENANT'S REPRESENTATIVE WITH QUESTIONS OR CONCERNS REGARDING INSTALLATION. 8, JUNCTION BOX POSITION: (1)3"x3"JUNCTION BOX INSTALLED ABOVE CEILING NO MORE AND QUANTITIES OF SENSORS SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC, THE CONTRACTOR SHALL PROVIDE ADDITIONAL SENSORS IF REQUIRED TO THAN 12"FROM DOOR. PROPERLY AND COMPLETELY COVER THE RESPECTIVE ROOM. e O 5 -REFER TO ACS TYPE 60 TERMINATION,CABLE,AND ROUGH-IN DETAILS AS WELL AS THE SECURITY PROJECT NARRATIVE FOR DETAILED INSTALLATION INSTRUCTION. -DETAIL REPRESENTS A TYPICAL ROUGH-IN/INSTALLATION FOR THIS SYSTEM DEVICE 3. LOCATE SENSORS A MINIMUM OF 5'FROM SUPPLY AIR DIFFUSERS. INSTALL SENSORS ON SURFACES NOT SUBJECT TO VIBRATION. �� C"1 TYPE AND MAY NOT REPRESENT ACTUAL DOOR SWING OR WORK AREA BUILD- CONTACT -CARD READER IS FOR INGRESS ONLY AND PROVIDE FREE EGRESS. TENANT'S REPRESENTATIVE WITH QUESTIONS OR CONCERNS REGARDING INSTALLATION- 4. LOCATE SENSORS WHERE THEIR COVERAGE AREAS ARE NOT SCREENED BY LIGHT FIXTURES AND ARCHITECTURAL ELEMENTS. Z C 8 REFER TO ACS TYPE 70 TERMINATION, CABLE.AND ROUGH-IN DETAILS AS WELL AS THE 5. CONTACT WATT STOPPER AT 1-800-879-8585 FOR PRODUCT SUPPORT_ Lab- 6 SECURITY PROJECT NARRATIVE FOR DETAILED INSTALLATION INSTRUCTION. -CARD READER IS FOR INGRESS ONLY AND PROVIDE FREE EGRESS. 6. INSTALL DT-200 SENSOR ON CEILING TILE WHENEVER POSSIBLZE 7. SEE DETAIL 3/E-102 FOR TYPICAL WIRING DIAGRAMS. W B. E.C. SHALL INSTALL OCCUPANCY SENSORS PER MANUFACTURER'S PUBLISHED INSTRUCTIONS,SET AUTO/MANUAL ON FUNCTION,TIMED OFF FUNCTION, NOTE: E.C. SHALL PROVIDE ROUGH-IN ONLY ALL DOOR HARDWARE, WIRING, TERMINATION SENSITIVITY AND DAY-LIGHTING OPTIONS PER THE TENANTS DIRECTIONS. ADJUST TO SATISFACTORY OPERATION OF THE TENANT AND ARCHITECT. Q AND HARDWARE INSTALLATION WILL BE BY OTHERS- Q SECURITY SYSTEM ROUGH-IN DETAILS E-102 NO SCALE t i Neutral Control Cutout ' Any Neutral Common 24VDC LIGHTING +24VDC Ceiling/Wall 3-Way LIGHTING LOAD Sensor Switches LOAD NV N DIMMER SWITCH Travelers Neutral _ Wht Red . - LIGHTING Power 1 LOAD Hot _ Blk f SII Pack T Red Wht Red I Power i Line Blk Red " Hot Blk SII Pack T Red , Neutral i 1 Neutral Wht I WALL EXISTING Green I SWITCH DIMMER __ ro o OR a m m BUS SWITCH LIGHTING Control C)utOut ,' Any !'JCommon _ LOAD 24VDC Ceil 24VDC Ground inglWall Sensor CO DW-100 WALL SWITCH ANY 24VDC SENSOR CONTROLLING DUAL LEVEL LIGHTING CEILING SENSOR WITH 3-WAY SWITCHING DIMMER Q OR SWITCH LIGHTING DIMMER Neutral I, Wht Red OR W Power ✓� LOAD LIGHTING DIMMER [ 111 Pack T Red Neutral Wht Red SWIT� LOAD 2 ORHot Blk Power1EXIST. Neutral Wht Red SWI% LIGHTING Y I Hot I Bik ( III Pack T }Red 0 "XB-5" Power .1. LOAD II a) cc m� I ��1 (E) Hot Rik SII Pack T 1 Red - c CA EXIST. ® EXIST. EXIST. EXIST EXIST. I EXIST. EXIST. EXIST. EXIST. 100/43 1 IClAny a _ _ J Common 24VDC ix m m "2B5C" "4C5" "2A2AB" "4A5" "2A5" iii 75 KVA "2B5B-1" "2B5" "2B5A" "4135" (E) Neutral +24VDC Cutout Ceiling/Wall Y �, Control Output . Any ♦ ♦ Q 60A, 250A 250A. 125A. 100A_ -, I 200A. 250A. 250A. 250A. Sensor Common _ 24VDC U H 2001-13 Control Output An +24VDC Ceilin /Wall W M.C.B. M.L.O. M.L.O. M.L.O. M.C.B. I I I M.C.B. M.L.O. M.L.O M.L.O. Y g (E) Common _ 24VDC Control Output Any . - Sensor EXIST. 2001!3 +24VDC . _Sensor/Wall Common 24VDC ( � "XA5" +24VDC CeilingNVall Control Outout , Any �+ Se_n_s_o__r _ Common 24VDC W (E) DIMMER Local - +24VDC Ceiling/Wall J Z OR - OffLIGHTING - Sensor W Q 30 KVA SWITCH SwitchRed /i LIGHTING Neutral,Wht - Red ➢/._ LOAD Auxiliary 1 LOAD Power 1 Control_Outout Any Relay Pack T Red Hot Blk III Pack Red Common Ceiling/Wall DATE 5TH FLOOR Hot Blk I 1 24VDC05/23/2018 IJ I.. . ` I Sensor 1 NeuiraI T Neutral r-J SCALE AS NOTED TWO CIRCUIT OR TWO LOAD SENSOR CONTROL MULTIPLE OCCUPANCY SENSORS CONTROLLING TWO CIRCUITS MULTIPLE OCCUPANCY SENSORS USING ONE POWER PACK MGR JRA 2 ELECTRICAL RISER DIAGRAM d OCCUPANCY SENSOR WIRING DIAGRAMS JOB CENO14 E-102 NO SCALE (SHOWN FOR REFERENCE) E-102 NO SCALE SHEET OTE: MAXIMUM NUMBER OF SENSORS PER POWER PACK DEPENDS ON THE MODEL OF SENSOR.SEE THE PRODUCT DATA E .102 S SHEET TO DETERMINE THE SPECIFIC CURRENT CONSUMPTION OF EACH SENSOR. OF SHEETS IHDL DESIGN HEREB1 EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I 0) REVISIONS BY UL r a. 0% ti o ¢/ w o v ~ O ¢ 8 � Z ,T._ z o m s 0 ,D z w U z PANELBOARD SCHEDULE PANELBOARD SCHEDULE PANELBOARD SCHEDULE04 roZce if), DESIGNATION/l D• 4B5 TYPE OF PANEL: CIRCUIT BREAKER** MOUNTING• SURFACE DESIGNATION/I.D, 4C5 TYPE OF PANEL: CIRCUIT BREAKER** MOUNTING: SURFACE DESIGNATION/LD: 2A5 TYPE OF PANEL: CIRCUIT BREAKER"" MOUNTING: SURFACELtiL7¢ W o VOLTAGE: 277 / 480 /3PH-4W BUS SIZE(AMPS): 250 MAIN SWITCH, M.L.O. MAIN RATING AIC 14k VOLTAGE: 277 / 480 /3PH-4W BUS SIZE(AMPS): 250 MAIN SWITCH: M.L.O. MAIN RATING AIC 14k VOLTAGE: 120 / 208 /3PH-4W BUS SIZE (AMPS): 125 MAIN SWITCH: 100A MCB MAIN RATING AIC 10k Z L- 4a'N 0 C Eo POLES: 3PSN LUGS: STANDARD TOTAL SPACE REQUIRED: 42 NOTES: POLES: 3PSN LUGS: STANDARD TOTAL SPACE REQUIRED: 42 NOTES: POLES: 3PSN LUGS: STANDARD TOTAL SPACE REQUIRED: 42 NOTES: I PROVIDE 2P/3P HANDLE TIE Z ¢ o c U •CO ,0 ¢ 6 FEEDER: SEE RISER DIAGRAM POWER SOURCE: SEE RISER DIAGRAM FEEDER: SEE RISER DIAGRAM POWER SOURCE: SEE RISER DIAGRAM FEEDER: SEE RISER DIAGRAM POWER SOURCE SEE RISER DIAGRAM Z I- • V) d a o CO DO 6 C c c c C c c c C c c c ❑ A7-' 0 . MM `m K LOAD(WATTS) L L LOAD(WATTS) K K LOAD(WATTS) L L LOAD(WATTS) K K LOAD(WATTS) L L LOAD(WATTS) K 0 °� o T C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B Q o. ^^ v 5 S T T s s T T s s T # AO BO CO S S AO BO CO u # AV BO CO S S AO BO CO # # AO BO CO S s AO BO CO # 0' c 1 20/1 2000 L EXIST- LIGHTING EXIST-W5-1,2,6,7,8 H 3667 25/3 : 2 1 i• 20/1 I 2000 L EXIST. LIGHTING EXIST. FPU H 3000 20/1 2 1 20/1 500 R EXIST. SECURITY EXIST. CONF. REC, R 1260 20/1 2 _J N .• � . oU " o 3 20/1 2000 L EXIST. LIGHTING -- H 3667 - 4 3 1 20/1 2000 L EXIST. LIGHTING EXIST. FPU H 5500 2011 4 3 1 20/1 I 360 R EXIST. PENTHOUSE REC. EXIST. SYSTEM FURN. R 1080 . 20/1: 4 /� U 0 a_ 8 5 20/1 2000 L EXIST. LIGHTING -- H 3667 - 6 5 , 20/1 2000 L EXIST. LIGHTING EXIST. FPU H 4000 2011 6 5 1 20/1 1500 H EXIST. PENTHOUSE HEATER -- R 1440 [ 20/1 6 . (N1): 0 .__ v 7 2011 2000 L EXIST. LIGHTING EXIST. FP5-1,2,3,13 H 7000 30/3 8 7 20/1 2000 L EXIST- LIGHTING EXIST.W5-1,2,3,4,5,10,11 H 5166 30/3 8 7 € 20/1 500 M1 EXIST. EF-5 EXIST. REC, R 180 20/t 8 � • .mac 9 20/1 2000 L EXIST. LIGHTING -- H 7000 - :10 9 20/1 2000 L EXIST. LIGHTING -- H 5166 10 9 2012 1500 H EXIST. FC-1 REC.-CONF.,COLLABORATION R 360 20/f 10 ' cj PROFESS 11 20/1 2000 L EXIST- LIGHTING -- H 7000 - 12 11 2011 2000 L EXIST. LIGHTING -- H 5166 - 12 11 - . 1500 H -- EXIST. HOTEL,COLLAB, REC. R 1620 20/i: 12 �'` _C,4NEEq ..'G - 13 20/3 3000 R EXIST. METER EXIST. FP5-10,11,12,18 H 7200 30/3 14 13 20/3 • 4000 R EXIST. METER EXIST. FP5-4 H 1667 30/3 14 13 20/1 360 R EXIST. PENTHOUSE REC. SYSTEM FURNITURE R 1080 20/2 14 7.•33PE 15 - 3000 R -- -- H 7200 - 16 15• - 4000 R -- -- H 1667 - 116 15 20/1 1500 K EXIST. WATER HEATER -- R 1440 - 16 17 - 3000 R -- -- H 7200 - 18 17 - 4000 R -- - H 1667 - 18 17 1P - SPACE SPACE - 1P 18 11 --- A t i\ is 20/1 - SPARE SPARE - 20/1 201 19 40/2 2500 A2 EXIST. CU-1 SPACE - 1P 20 I 1" �; 8,2 0` , 211 20/1 2000 L EXIST. LIGHTING H 2500 22 21' — .. —__..._.. 19 20/1 � 2000 L EXIST. LIGHTING EXIST. FP5-17,19 H 2500 30/3 20 19, - 20/1 SPARE SPARE 20/1 22 21 2500 A2 SPACE 1P 22 L/ �N.--Or' 23 20/1 - OFF -- H 2500 - 24 23' 20/1 I - SPARE SPARE - 20/1 24 23 4012 2500 A2 EXIST. CU-2 SPACE - 1P 24 MAY 2013 25 20/3 4000 H VV5-14,15 EXIST. FP5 H 7000 35/3 .':'26 25 I 20/3 4000 H EXIST. FP 4TH FLOOR EXIST. FP5-21 H 3000 15/1 E 26 25 - 2500 A2 -- SPACE - 1P 26 27 - 4000 H --- -- H 7000 - 28 27 - 4000 H -- EXIST. FP5-22 H 3000 ; 15/1 28 27 40/2 2500 A2 EXIST, CU-3 SPACE - 1P '28 W 29 - 4000 H -- -- H 7000 - .30 29 - 4000 H -- EXIST. FP5-23 H 3000 15/1 I 30 29 - 2500 A2 -- SPACE - 1 P30 i 31 100/3 46060 XF XB-5 EXIST. FP5 H 3500 20/3_32 31 1P - SPACE EXIST.WATER HEATER K 8320 i_40/1 32 311 1P - SPACE SPACE - 1P 32 �O O Q 33 - 40660 XF XB-5 -- H 3500 - 34 33 1P I - SPACE MOTHERS RM WATER HEATER K 8320 40/1 34 33 100/3 2700 XF 2A2AB SPACE - 34 O 35 -� 38960 XF XB-5 -- H 3500 - '36 35 IP - SPACE BREAK RM HWATER HEATER K ' 6320 40/1 36 35 1 - I 1980 XF 2A2AB SPACE - 36 LIJE 0 37 20/3 H EXIST FAN PWR UNITS VV5-16,17 H 4333 20/3 38 37 1P - SPACE SPACE - . 1P. 38 371 - 3240 XF 2A2AB SPACE - 38 39 - H -- -- H 4333 - 40 39 1P - SPACE SPACE - 1P 40 391P - SPACE SPACE 1P'. 40 8 41 - H -- -- H 4333 - 42 41 1P _ - SPACE SPACE - 1P • 42 411 1P J - SPACE SPACE - 1P ' 42 Z 1 J TOTALS 59060 53660 49960 35200 35200 35200 TOTALS TOTALS - 12000 12000 12000 21153 23653 22153 TOTALS TOTALS 9600 11060 9980 2520 2880 3060 TOTALS LILI (,) 6 PROVIDE LOCK ON DEVICE *PROVIDE LOCK ON DEVICE `PROVIDE LOCK ON DEVICE 0 CONNECTED LOAD: NOTES: •-10,000 AIL.RATING UNLESS OTHERWISE SPECIFIED CALC DEMAND CONNECTED LOAD: NOTES: **10,000 A.I.C. ATING UNLESS OTHERWISE SPECIFIED CALC. DEMAND CONNECTED LOAD: NOTES: -10,000 A.I.C.RATING UNLESS OTHERWISE SPECIFIED CALL. DEMAND (VOLT-AMPERE) 268,28aVA LOAD AMPERE: 277A (VOLT-AMPERE) 102,959VA LOAD AMPERE: 139' (VOLT-AMPERE) 39,100VA LOAD AMPERE: 78A CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE,Al=1PH AIC LOAD,A2=2PH A/C LOAD,A3=3PH AIC CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE, A1=1PH AIC LOAD,A2=2PH AIC LOAD, A3=3PH A/C CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE,A1=1PH A/C LOAD,A2=2PH AIC LOAD,A3=3PH AIC LOAD, H=HEATING, K=KITCHEN;XF=TRANSFORMER-PANEL; SF=SUB-FEED LOAD, H=HEATING, K=KITCHEN; XF=TRANSFORMER-PANEL, SF=SUB-FEED LOAD, H=HEATING, K=KITCHEN;XF=TRANSFORMER-PANEL, SF=SUB-FEED NOTE: EXISTING PANELBOARD. ELECTRICAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO NOTE: EXISTING PANELBOARD. ELECTRICAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO NOTE: EXISTING PANELBOARD. ELECTRICAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO CONNECTING NEW CIRCUITS. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS. PROVIDE NEW TYPE WRITTEN PANEL CONNECTING NEW CIRCUITS. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS-PROVIDE NEW TYPE WRITTEN PANEL CONNECTING NEW CIRCUITS. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS. PROVIDE NEW TYPE WRITTEN PANEL DIRECTORY WHEN COMPLETE. FOR EXISTING LOADS,OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY, BUILDING ENGINEER OR TRACE DIRECTORY WHEN COMPLETE. FOR EXISTING LOADS,OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY, BUILDING ENGINEER OR TRACE DIRECTORY WHEN COMPLETE- FOR EXISTING LOADS, OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY,BUILDING ENGINEER OR TRACE OUT LOADS- INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. OUT LOADS. INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. OUT LOADS. INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. I LOAD DESCRIPTION 20/1 CT. ' DENOTES EXISTING C/B I LOAD DESCRIPTION 1 2011 . CT. DENOTES EXISTING C/B I LOAD DESCRIPTION 2011 CT. DENOTES EXISTING C/B I LOAD DESCRIPTION 2011 CT. DENOTES NEW C/B. MATCH EXISTING CIRCUIT BREAKER RATINGS I LOAD DESCRIPTION 2011 CT. DENOTES NEW CIS. MATCH EXISTING CIRCUIT BREAKER RATINGS I LOAD DESCRIPTION 2011 CT. . DENOTES NEW CIB. MATCH EXISTING CIRCUIT BREAKER RATINGS M PANELBOARD SCHEDULE PANELBOARD SCHEDULE PANELBOARD SCHEDULE DESIGNATION/LD: 2B5 TYPE OF PANEL CIRCUIT BREAKER"" MOUNTING: SURFACE DESIGNATION/LD: 2B5A TYPE OF PANEL CIRCUIT BREAKER"" MOUNTING: SURFACE DESIGNATION/LD: 2B5C TYPE OF PANEL CIRCUIT BREAKER`" MOUNTING: SURFACE e 0 5 VOLTAGE, 120 / 208 13PH-4W BUS SIZE(AMPS)' 250 MAIN SWITCH: M.L.O. MAIN RATING AIC 10k VOLTAGE 120 1 20$ 13PN-4W BUS SIZE(AMPS): 250 MAIN SWITCH: M.L.O. MAIN RATING AIC 10k VOLTAGE: 120 / 208 l3PH-4W BUS SIZE(AMPS): 250 MAIN SWITCH 60A MCB MAIN RATING AIC 10k IIIII CrlM POLES: 3PSN LUGS: STANDARD TOTAL SPACE REQUIRED: 42 NOTES: I PROVIDE 2P/3P HANDLE TIE POLES: 3PSN LUGS, STANDARD TOTAL SPACE REQUIRED. 42 NOTES: I PROVIDE 2P/3P HANDLE TIE POLES: 3PSN LUGS: STANDARD TOTAL SPACE REQUIRED: 42 NOTES: Z O g. 1. FEEDER: SEE RISER DIAGRAM POWER SOURCE. SEE RISER DIAGRAM FEEDER: SEE RISER DIAGRAM POWER SOURCE: SEE RISER DIAGRAM FEEDER: SEE RISER DIAGRAM POWER SOURCE: SEE RISER DIAGRAM W C c c c C c c c C c c c I-- ige, K LOAD(WATTS) L L LOAD(WATTS) K K LOAD(WATTS) L L LOAD(WATTS) K K LOAD(WATTS) L L LOAD(WATTS) K Z C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B C/B A LOAD DESCRIPTION LOAD DESCRIPTION A C/B T s S T T s s T T s s T # AO BO CO s s AO BO CO # ILIA # AO BO CO s s AO BO CO # # AO BO CO s s AO BO CO # Q 1 20/1 1400 N EXIST. W PRINTER BAR EXISTING R 360 2011 2 1 20/1 1800 R EXIST. SYSTEM FURNITURE BRK RM MICROWAVE R 1500 2011 2 1 20/1 J 720 R N SYSTEM FURNITURE PRINT COPIER R 1000 20/1 � 2 0 3 20/1 1620 R EXIST.OFFICES.OP OFF REC. EXISTING R 360 20/1 4 3 2011 1080 R EXIST. SYSTEM FURNITURE BREAK RM COUNTER REC. R 1500 20/1 4 3 0/1 ' 900 R REC.-N OFFICE,OEPN OFFICE SPACE - 1P 4 5 2011 1620 R EXIST.CONF ,CORK. REC. EXIST. W SYSTEM FURNITURE R 1440 2011 ; 6 5 2011 1080 R -- BRK RM TOASTER R 1500 2011 6 5 0 i 11 1440 R REG.-N OFFICE,OP.OFF.,PRINT PRINT COUNTER REC. R 1000 2011 6 7 20/1 1620 R REC. HUDDLE,STOR.,OP OFF - R 1440 20/1 8 7 20/1 T 1080 R EXIST. SYSTEM FURNITURE BRK RM REFRIGERATOR R 1000 1P 8 7 40/1 1260 R OFFICES,OPEN OFFICE 1000 20/1 8 9 20/1 1260 R REC.-STAR.,MOTHERS,OP. OFF. SPARE 20/1 10 9 2011 i 1080 R -- EXIST.OFF.,COFFEE,OP.OFF.REC. R 1440 1- 201 10 9 - SPAREREC HUDDLE RMS,OP.OFFICE R 1620 20/1 10 11 20/1 1000 R MOTHER'S REFRIGERATOR -- - 20/1 I. 12 11 20/1 1440 R EXIST. SYSTEM FURNITURE EXIST.OFFICES,OPEN OFFICE REC. R 1440 • 20/1 12 11 '0/1 - SPARE N SYSTEM FURNITURE R 720 20/1 ' 12 13 20/1 - SPARE EXIST.W SYSTEM FURNITURE R 1440 20/1 14 13 2011 1440 R EXIST SYSTEM FURNITURE SPARE 30/2 14 13 - •;•,'.I/1 - SPARE SPARE - 2011 14 - - ___MOM • , 15 20/1 SPARE EXIST. W COPIER R 1080 2011 16 15 20/1 1620 R REC. BREAK ROOM 16 15 '0I2 1440 R N SYSTEM FURNITURE SPARE 2011 1fi Csi 17� 20/1 - SPARE W SYSTEM FURNITURE R 1080 20/1 18 17 20/1 I 800 R REC. -TRAINING EXIST.OFFICE,OPEN OFF.,CONF.REC. R 1080 20/1 18 17 ` 1440 R -- SPARE - 20/1 18 P 19 I 20/1 1500 R EXIST. COFFEE BAR MICRO. -- R 1080 20/1 i 20 19 20/1 800 R REC. -TRAINING EXIST.-OFFICE, CONF. REC. R 1440 2011 20 19 . 1080 R N SYSTEM FURNITURE SPARE • 20/1 20 21 2011 I 1500 R EXIST. COFFEE BAR COUNTER -- R 1440 20/1 22 21 20/1 1 800 R REC. -TRAINING EXIST SPLIT SYSTEM COOL. A2 1500 20 22 21 ---.:. 1080 R -- SPARE - 20/1 22 23I 2011 1000 R EXIST. COFFEE BAR REFRIG. NE SYSTEM FURNITURE R 1080 20/1 24 23 20/1 800 R REC TRAINING A2 1500 24 23 `sf 1080 N N SYSTEM FURNITURE SPARE - 20/1 24 I 251 20/1 1500 R EXIST,COFFEE BAR COUNTER -- ,. 1080 20/1 ,.26 25 20/1 800 R REC. -TRAINING BRK RM MICROWAVE R 1500 2011`- 26 25 - 1080 R -- SPARE - 2011 26 27 1 20/1 1500 R EXIST.COFFEE BAR COFFEE MAKER NE SYSTEM FURNITURE R 1080 2011 28 27 ,20/1 800 R REC. -TRAINING REC. -BRK RM COUNTER R 1500 2011 28 27 - SPARE SPARE - 20/1 28 29 2011 1500 R EXIST.COFFEE BAR ICE MACHINE -- R 1080 20/1 130 29 •20/1 800 R REC. -TRAINING BREAK RM COUNTER REC. R 1500 20/1 • 30 29 ;• - -- SPARE - j20/1 31 2011 360 R EXIST. COFFEE BAR REC. NE SYSTEM FURNITURE R 1080 20/1 32 31 2011 800 R REC. TRAINING BRK RM COFFEE MAKER R 1500 20/1 32 31al - SPARE SPARE CO 33 1P - SPACE N SYSTEM FURNITURE R 1440 I 2011 34 33 20/1 800 R REC. -TRAINING BRK RM REFRIGERATOR R 1000 2011!-- 34 33 ' - -- SPARE - v� 35 2011 - SPARE SPARE - 2011 36 35 20/1 800 R REC. -TRAINING BREAK RM COUNTER REC. R 1500 2011 36 35 - -- -- - , W _ J 37 1P - SPACE SPARE - i 2011 38 37. 20/1 • 800 R REC. -TRAINING EXIST. W UNIT R 1500 2011 38 37 - SPARE SPACE - 1P38 39 20/1 _ - SPARE SPARE - . 2011 40 39: 20/1 1000 R REC.-TRAINING SPARE 30/1 40 39 - SPARE SPACE - 1P . .,. 40 W 41 20/1 • - SPARE SPARE - 20/1 42 41, 20/1'. 1440 R REC.-TRNG, CORRIDOR SPACE - 1P - 42 41 1 - SPARE SPACE - 1P 42 I TOTALS 5980 5880 5120 6480 5400 4680 TOTALS TOTALS 7520 7180 7160 8440 6940 8520 TOTALS TOTALS 4140 3420 3960 2000 1620 1720 TOTALS U PROVIDE LOCK ON DEVICE 'PROVIDE LOCK ON DEVICE "PROVIDE LOCK ON DEVICE CO VJ CONNECTED LOAD: 33,540VA NOTES: A.I.C. S OTHERWISE SPECIFIED CALC. DEMAND 172A CONNECTED LOAD: 45,760VA NOTES: ..10I,00a A C RATING UNLESS OTHERWISE SPECIFIED CALC. DEMAND 172A CONNECTED LOAD: 16,860VA NOTES: ••10,000 A.I.C.RATING UNLESS oTHERVVISE SPECIFIED CALC. DEMAND 37A V1 (VOLT-AMPERE) I LOAD AMPERE: (VOLT-AMPERE) I LOAD AMPERE, (VOLT-AMPERE) LOAD AMPERE: J CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE,Al=1PH A/C LOAD,A2=2PH AIC LOAD,A3=3PH A/C CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE, Al=1PH A/C LOAD,A2=2PH A/C LOAD,A3=3PH A/C CLASS: M1=SINGLE PH MOTOR; M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE,A1=1PH A/C LOAD,A2=2PH A/C LOAD,A3=3PH A/C Q/ J LOAD, H=HEATING, K=KITCHEN;XF=TRANSFORMER-PANEL; SF=SUB-FEED LOAD, H=HEATING, K=KITCHEN; XF=TRANSFORMER-PANEL, SF=SUB-FEED LOAD, H=HEATING, K=KITCHEN:XF=TRANSFORMER-PANEL; SF=SUB-FEED V Q NOTE: EXISTING PANELBOARD. ELECTRfCAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO NOTE: EXISTING PANELBOARD. ELECTRICAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO NOTE EXISTING PANELBOARD. ELECTRICAL CONTRACTOR SHALL VERIFY PANEL LOADING AND REPORT READINGS TO ENGINEER PRIOR TO CONNECTING NEW CIRCUITS. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS. PROVIDE NEW TYPE WRITTEN PANEL CONNECTING NEW CIRCUITS PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS. PROVIDE NEW TYPE WRITTEN PANEL CONNECTING NEW CIRCUITS. PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED FOR NEW LOADS. PROVIDE NEW TYPE WRITTEN PANEL DIRECTORY WHEN COMPLETE. FOR EXISTING LOADS,OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY,BUILDING ENGINEER OR TRACE DIRECTORY WHEN COMPLETE. FOR EXISTING LOADS,OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY, BUILDING ENGINEER OR TRACE DIRECTORY WHEN COMPLETE. FOR EXISTING LOADS,OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY,BUILDING ENGINEER OR TRACE i• % OUT LOADS. INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. OUT LOADS. INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. OUT LOADS. INDICATE ON THE PANEL DIRECTORY CIRCUITS SERVING EMERGENCY AND EXIT LIGHTING. �y 0 I LOAD DESCRIPTION 20/1 CT. DENOTES EXISTING C/B LOAD DESCRIPTION 20/1 CT. DENOTES EXISTING C/B f LOAD DESCRIPTION 20/1 CT. DENOTES EXISTING C/B '� r I LOAD DESCRIPTION 20/1 CT. DENOTES NEW CIB, MATCH EXISTING CIRCUIT BREAKER RATINGS LOAD DESCRIPTION 20/1 CT. DENOTES NEW C/B. MATCH EXISTING CIRCUIT BREAKER RATINGS LOAD DESCRIPTION 20/1 CT. DENOTES NEW CIB, MATCH EXISTING CIRCUIT BREAKER RATINGS I�,I DATE 05/23/2018 SCALE AS NOTED MGR JRA JOB CENO14 SHEET E -103 OF SHEETS IHDL DESIGN HEREBIEXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISIGN OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I ! in REVISIONS BY Z - oo cu Q "' g_ E✓ cx M Activity Area Pre-Alt. Post-Alt. Fixtures ReptiAdded Q o OU n Conference 501 (Common Space 199 176 NrA 2 55 e5 se C7 T s:Conference?Meetfr ?Multi a ose 388 h. : Exemption: ¢ Z Yf� 9 PrP �- ) Q aC et COMeheck Software Version 4.0.8.2 Less than 10 fixtures replaced. z o M lifill L Corridor(Common Space Types:Corridor/Transitlon 1225 sq.ft.): 1739 1377 21 0ce Z Lu Interior Lighting Compliance Exemption Less than 10%fixture replacement. et U Z_. �; Open Office 519(Common Space Types:Office-Open Plan 206 243 t 62 3 0 ` Z Z soft.): Exemption:Less than 10%fixture replacement. N Certificate Break 522(Common Space Types:Dining Area-Bar Lounge/Leisure 1206 1 134 23 0oitt Z y ¢ ° p W 1072 sq.Ft.): Exemption:Less than 10%fixture replacement. M Z Multi-Purpose 522A(Common Space 162 60 2 0 it O se Section 1: Project Information Types:Conference/Meeting/Multipurpose 121 sq.ft): Exemption; Z 3• D C ■ r Less than 10%fixture replacement. Z M in N U Open Office 528333(Common Space Types:Office-Open Plan 5589 5508 68 0 Z• U `&-'' i t:0 6 a 2 Energy Code:2014 Oregon Energy Efficiency Specialty CodeVt !._ 6200 sq.ft.): Exemption: Less than 10%fixture replacement. W C w; U •- ao Project Title:Centene Corporation Q N g :, au v Project Type:Alteration Office 529{Common Space Types:Office Enclosed 149 sq_ft.) 162 162 N/A 0 Z I- V) +., w o 6 Exemption:Less than 10 fixtures replaced. co Z C J I t Construction Site: Owner/Agent: Designer/Contractor: Q re p 13221 SW 68th Parkway G&W Engineering Office 530(Common Space Types:Office•Enclosed 129 sq.tt.): 162 162 N/A 0 0 ea n Exemption:Less than 10 fixtures replaced. o 5th Floor 138 Weldon Parkway ❑ N �� a1 Office 531 {Common Space Types:Office-Enclosed 131 sq.ft.): 162 162 N/A 0 D r `4") r � U Tigard,OR 97223 Maryland Heights,MO 63043 Exemption:Less than 10 fixtures replaced. I 1 SS Section 2: Interior Lighting and Power Calculation Office 532(Common Space Types:Office-Enclosed 148 sq-ft.): 162 462 N/A 0 _i f� j a g gExemption:Less than 10 fixtures replaced. um. E+' = a o Storage 538Common Space T s:Active Storage 176 A B C D 9 ( P Yf� g sq.ft.): 243 90 3 0 � u L7 rL `` Exemption:Less than 10%fixture replacement. Q C Area Category Floor Area Allowed Allowed Watts mna Phone 539(Common Space Types:Office-Enclosed 42 vette: 81 30 1 0 er $ (ft2) Watts?tt2 (B x C) ■ ,-- Exemption: Less than 10%fixture replacement. Conference 501 (Common Space Types:Conference/Meeting/Multipurpose): Mothers 540(Common Space Types:Office-Enclosed 114 sq.tt_): 162 60 2 0 Exempt(Ceiling Height 9 ft.) c) P R OFFS Exemption:Less than 10%fixture replacement. ��cL,,' GAN E ER 0/0 Corridor(Common Space Types:Corridor/Transition):Exempt(Ceiling Height 9 Storage 541 Common Space TStorageq. ft) g ( p ypes:Active 199 s ft a 243 120 N/A 0 Exemption:Less than 10 fixtures replaced 9l Open Office 519(Common Space Types:Office-Open Plan):Exempt(Ceiling s 79'33PE cc Height 9 ft.) Section 3: Interior Lighting Fixture Schedule Break 522(Gammon Space Types:Dining Area-Bar Lounge/Leisure):Exempt g g (Ceiling Height 9 ft.) + Q �aN Multi-Purpose 522A(Common Space Types:Conference/Meeting/Multipurpose): A B C D E tit 1 Fixture ID :Description Lamp r Wattage Per Lamp t Ballast Lamps/ #of Fixture (C X 0) 41111 g,2QQ Exempt(Ceiling Height 9 ft.) 1�.. Training 523(Common Space Types:Ctassroorn/Lecture/Tralning)(Ceiling 1239 1.23 1524 Fixture Fixtures Watt. y _ . , Height 9 ft) Conference 501 (Common Space Types:Conference/MeetinglMultipurpose 388 sq.ft.):Exempt Open Office 528333(Common Space Types:Office-Open Plan):Exempt Corridor(Common Space Types:CorridorfTransition 1225 NA):Exempt rIAA.Y 9. 9 7 tf.Q,J._ (Ceiling Height 9 ff.) Open Office 519(Common Space Types:Office-Open Plan 206 sq.ft.):Exempt Office 529(Common Space Types:Office-Enclosed):Exempt(Ceiling Height 9 Break 522(Common Space Types:Dining Area-Bar Lounge/Leisure 1072 soft.):Exempt ft.) Multi-Purpose 522A(Common Space Types:Conference?Meeting/Multipurpose 121 sq.h.):Exempt Office 530(Common Space Types:Office• Enclosed):Exempt(Ceiling Height 9 in Training 523(Common Space Types:Classroom/Lecture/Training 1239 sq.(t.) ® 0 V Office 531 (Common Space Types:Office- Enclosed): Exempt(Ceiling Height 9 LED 1:Other 1 20 29.4 588 ag ft.) LED 2:Other: 1 3 14 42 Z O Office 532(Common Space Types:Office-Enclosed):Exempt(Ceiling Height 9 Open Office 528,533(Common Space Types:Office-Open Plan 6200 sq.ft.):Exempt W Q mem ft.) Office 529(Common Space Types:Office-Enclosed 149 sq.ft-):Exempt i Print 534(Common Space Types:Workshop)(Ceiling Height 9 ft.) 221 1.64 362 Office 530(Common Space Types:Office-Enclosed 129 sq.ft.):Exempt Huddle 535(Common Space Types:Conference/Meeting/Multipurpose)(Ceiling 78 1.11 87 Office 534S Height 9 ft.) (Common Space T ypes:Offiee Enclosed 194 sq.ft.):Exempt Z Huddle 536(Common Space Types:Conference/Meeting/Multipurpose)(Ceiling 78 1.11 87 Office 532(Common Space Types:Office-Enclosed 148 sq.ft.):Exempt Height 9 ft.) Print 534(Common Space Types:Workshop 221 sq.h.) W U Huddle 537(Common Space Types:Conference/MeetingtMultipurpose)(Ceiling 91 1.11 101 LED 3:Other: 1 3 29.4 88.2 Height 9 ft) Huddle 535(Common Space Types:Conference/Meeting/Multipurpose 78 sq.h,) m 0 Storage 538(Common Space Types:Active Storage):Exempt(Ceiling Height 9 LED 4:Other: 1 2 29.4 58.8 ft.) Huddle 536(Common Space Types:Conference/Meeting/Multipurpose 78 soft.) Phone 539(Common Space Types:Office-Enclosed):Exempt(Ceiling Height 9 ft.) LED 5:Other: 1 2 29.4 58.8 Mothers 540(Common Space Types:Office-Enclosed):Exempt(Ceiling Height Huddle 537(Common Space Types:Conference/Meeting/Muftipurpese 91 sq.ft.l 9 ft.) LED 6:Other: 1 2 29.4 58.8 Storage 541 {Common Space Types:Active Storage):Exempt(Ceiling Height 9 Storage 538(Common Space Types:Active Storage 176 sq.ft.):Exempt ft.) Phone 539{Common Space Types:Office-Enclosed 42 sq.tt.):Exempt Total Allowed Watts a 2161 Mothers 540(Common Space Types:Office-Enclosed 114 sq.ft.):Exempt Area Category Exemption Qualifications Storage 541 (Common Space Types:Active Storage 199 sgM4:Exempt Total Wattage Total Pre-Alt. #Fixtures Total Proposed Watts- 895 Project Title:Centene Corporation Report date:05/2208 Project Title: Centene Corporation Report date:05/22118 Data filename:F:12018 Projectst2018-0100.001EIectricallComcheck12018.0100.00WCentene Tigard Comcheck.cck Page 1 of 4 Data filename:F:'2018 Projects12018-0100.001Electricai\Comcheck12018-0100.00_Centene Tigard Comcheck.cck Page 2 of 4 201 Section 4: Requirements Checklist Plans reference page/section: E-401 § in the following requirements, blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks ✓ 13-Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an overnde switching device Z identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page./section'identifies where in that: 1) Is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or e d the plans/specs the requirement can be verified as being satisfied. so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an 5 , override is initiated.and 5)controls an area not exceeding 2,000 square feet. 11103 Lighting Wattage: p g ✓ 1. Total proposed watts must be less than or equal to total allowed watts. Plans reference page/section: Allowed Wattage:2161 Proposed Wattage:895 E Complies:YES 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature te 6 that turns oft all loads for at least 24 hours.then resumes the normally scheduled operation. Mandatory Requirements: ve 2_ Exit signs. internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: Z Plans reference page/section: 102 ✓ 15.Exterlor lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a 3 photosensor and a lime switch,or an astronomical lime switch,Lighting designated for dusk-to-dawn operation shall be controlled by ✓ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting an astronomical time switch or photosensor0 in the non-daylight zone. In all individual daylight zones larger than 350 soft..automatic daylight controls is provided.Automatic a daylight sensing controls reduce the light output of the control led luminaires at least 50 percent,and provide an automatic OFF control, Plans reference page?section• while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a ▪ 16,Tandewiring.The following luminaires located within the same area shall be tandem wired: a' single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e., north,east. m 1. Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. center-to-center of each other. 1 Exception applies:Spaces required to have occupancy sensors. 2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted t i Plans reference page/section: (-401 within 1 foot edge-to edge of each other. ✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2.000 square feet of lit floor area and Plans reference pager'section • each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are ✓ 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control a remote switch that identifies the lights served and indicates their status. of the nonexempt lighting. P Plans reference page/section:j -401 Plans reference page/section• r/ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. • 18.Each dwelling unit in a building Is metered separately. Plans reference page/section: Plans reference page/section: r/ 6. Egress lighting. Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Interior Lighting PASSES Plans reference page/section: Section 5: Compliance Statement ✓ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and LL! Plans reference page/section: E-401 other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2014 Oregon Energy U ✓ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least Efficiency Specialty Code requirements in COMcheck Version 40.8.2 and to comply with the mandatory requirements in the Requirements Z 50 percent by either Checklist. Q 1)controlling(dimming or multi-level switching)ail luminaires;orj 2)dual switching of alternate rows of luminaires.alternate luminaires,or alternate lamps;or Kevin S. Griesemer- Principal 05/23/2018 3)switching the middle lamp luminaires independently of other lamps;or Name-Title Signa re Date 4)switching each luminaire or each lamp. 3 ,/ Exception applies:An occupant-sensing device controls the area. Plans reference pageisection: E-407 U re 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic N4 control device shall function on either: 1)a scheduled basis, using time-of-day,with an Independent program schedule that controls the interior lighting in areas that do not 0 exceed 10.000 square feet and are not more than one floor;or W 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space:or CO3)a signal from another control or alarm system that indicates the area is unoccupied. ♦ Plans reference page/section: E-4O1 MCC r/ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. E.3 2 Plans reference page/section: ✓ 11 An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Plans reference page/section: E-401 DATE 05/23/2018 ✓ 12Additionat controls.An occupant sensor control device that automatically turns lighting off within 30 minutes at all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and SCALE supply rooms up to 1000 square feet. AS NOTED IIGR JRA JOB CENO14 Project Title: Centene Corporation Report date' 05/22/18 Project Title: Centene Corporation Report date: 05/22/18 Data filename:F:12018 Projects12018-0100.001Electrical\Comchecki2018-0100.00_Centene Tigard Comcheck.cck Page 3 of 4 Data filename:F:`2018 Projects\2018-0100.001Electrical\Gomcheck12018-0100.00_Centene Tigard Comcheck.cck Page 4 of 4 SHEET E-104 OF SHIMS NT. HDL DESIGN HEREBi EXPRESSLY RESERVES RS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PART( WRHOUT FIRST 0BTAINiNG WRfTTEN PERMISSION AND CONSE I I I w REVISIONS BY F v 8 Z N PLAN NOTES - ELECTRICAL DEMOLITION GENERAL DEMOLITION NOTES ° ce R. o co ¢ . fou, 7 1. DEMOLISH ALL ELECTRICAL DEVICES AND EQUIPMENT SHOWN IN THE BACK TO ABOVE CEILING AND COILED. COORDINATE WITH TENANT A. FIXTURES, DEVICES AND EQUIPMENT INTENDED FOR DEMOLITION ARE H. WHERE DEVICES, FIXTURES OR BOXES ARE REMOVED FROM WALLS, - - O a ] � z r AREA OF WORK AS INDICATED WITH DARK LINES AND HATCHING. PRIOR TO PROCEEDING WITH ANY WORK. SHOWN WITH DARK LINES AND HATCHING; REFER TO PLAN NOTES FOR CEILINGS OR FLOORS THAT DO REMAIN, PATCH AND FINISH WITH Z ,O t g t REMOVE UNUSED BOXES AND CONDUIT. IF WALL REMAINS, PATCH ADDITIONAL INFORMATION. MATERIALS MATCHING THE SURROUNDING SURFACES. U F IF Z W WALL WITH MATERIALS TO MATCH SURROUNDING SURFACES. REMOVE 12. EXISTING LIGHTING AND POWER SHALL BE MAINTAINED IN THIS AREA 9 Z C7 WIRING BACK TO PREVIOUS DEVICE OR PANEL. MAINTAIN CONTINUITY U.O.N. MAINTAIN CONTINUITY OF EXISTING SWITCHING AND CIRCUITS. B. THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING I. WHERE THE EXISTING ELECTRICAL DEVICES REMAIN, ALL NON-WHITE, r Z Z OF CIRCUITS SERVING DEVICES AND FIXTURES REMAINING AFTER CONDITIONS. CONTRACTOR SHALL REQUEST CLARIFICATION TO ANY PAINTED OR DAMAGED SWITCHES, RECEPTACLES AND COVER PLATES z r o - DEMOLITION. PROVIDE JUNCTION BOXES ABOVE CEILINGS TO SPLICE 13. EXISTING ALARM STROBE SHALL BE CAREFULLY REMOVED. DISCREPANCIES IN THE EXISTING DEVICES OR EQUIPMENT INDICATED SHALL BE CHANGED OUT FOR NEW WHITE DEVICES AND COVER w n E&' C Ui CIRCUITS WHERE REQUIRED. FIELD VERIFY DEVICE AND FIXTURE COORDINATE WITH THE PROPERTY MANAGER PRIOR TO DISPOSAL. ON THESE CONTRACT DOCUMENTS PRIOR TO BID. PLATES. COUNT PRIOR TO BID. W O 14. DISCONNECT EXISTING FURNITURE WHIPS, RELOCATE AS REQUIRED C. DEMOLISH ALL FIXTURES, DEVICES AND EQUIPMENT THAT EXIST IN J. WHERE THE EXISTING LIGHT FIXTURES REMAIN OR GET RELOCATED, U oC ■ r 2. EXISTING LIGHT FIXTURES INDICATED WITH DARK LINES AND HATCHING AND RECONNECT TO MODULAR FURNITURE. TENANT'S DATA CABLES WALLS, FLOORS AND CEILINGS BEING DEMOLISHED INCLUDING PIPING, REPAIR AND/OR RELAMP FIXTURE/REPLACE BALLAST AS REQUIRED Z U S P � m C 0 a o SHALL BE CAREFULLY REMOVED FOR RELOCATION. FIXTURES NOT SHALL BE PULLED BACK AND COILED ABOVE CEILING. TENANT WILL WIRING AND RACEWAYS WHETHER INDICATED OR NOT. ENSURING ALL FIXTURES ARE FUNCTIONAL WHEN THE SPACE IS W a. U �+` I . v BEING RELOCATED SHALL BE PROPERLY DISPOSED OF; COORDINATE REINSTALL CABLES. COORDINATE WORK WITH TENANT. TURNED OVER TO THE TENANT. THE REPLACEMENT LAMP TYPE, Z �' Q y 0 °r v WITH THE PROPERTY MANAGER PRIOR TO DISPOSAL. D. RELOCATE ALL FIXTURES, DEVICES AND EQUIPMENT THAT EXIST IN OR WATTAGE AND COLOR MUST MATCH THE SURROUNDING FIXTURES OF >- d' Z C _v o o 15. COORDINATE WITH TENANT SECURITY SYSTEM SUPPLIER THE ON WALLS, FLOORS AND CEILINGS WHICH CONFLICT WITH NEW WALL THE SAME TYPE. in v 0 W n n 3. EXISTING FIRE ALARM SYSTEM SIGNAL SHALL BE CAREFULLY REMOVED. REMOVAL OF THE DOOR CONTROL CARD ACCESS HARDWARE OR CEILING CONSTRUCTION WHETHER INDICATED OR NOT. 0 a h e` 0 DEVICES NOT BEING RELOCATED SHALL BE PROPERLY DISPOSED OF; INCLUDING CARD READER, DOOR CONTACT AND REQUEST TO EXIT. K. ELECTRICAL BOXES, CONDUIT AND CABLES REMAINING AFTER 0 = V r COORDINATE WITH THE PROPERTY MANAGER PRIOR TO DISPOSAL. RETURN HARDWARE TO TENANT SECURITY SYSTEM SUPPLIER. E. WHERE ELECTRICAL FIXTURES, DEVICES OR EQUIPMENT ARE DEMOLITION SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH U - - E REMOVED, THE CONTRACTOR SHALL REMOVE ALL ASSOCIATED LINE NEC AND LOCAL AHJ. J p, > ' 4. EXISTING ELECTRIC PANELS TO REMAIN. REMOVE ALL ABANDONED 16. REMOVE ABANDONED IT RACKS, LADDER RACK, RECEPTACLES, VOLTAGE, LOW VOLTAGE AND COMMUNICATIONS WIRING BACK TO THE L j .i -5 WIRING AND TURN OFF ANY UNUSED CIRCUIT BREAKERS. CONDUIT SLEEVES THRU CEILING, PLYWOOD ON WALL, PUNCHDOWN PREVIOUS FIXTURE, DEVICE, PANELBOARD, PUNCHDOWN OR OTHER a 20 a `` o BLOCKS AND OTHER RELATED EQUIPMENT ALONG WITH ASSOCIATED SUCH POINT OF ORIGIN. WHERE WIRING IS REMOVED BACK TO A Q ° 0 5. EXISTING FIRE ALARM SYSTEM SMOKE DETECTOR SHALL BE REMOVED WIRING LOCATED WITHIN THIS ROOM. COORDINATE WITH PROPERTY PANELBOARD, TURN OFF ASSOCIATED CIRCUIT BREAKER AND LABEL AS Z ■ . 73 AND PROPERLY DISPOSED OF. COORDINATE WITH THE PROPERTY MANAGER PRIOR TO DEMOLITION. INFILL FLOOR TO MAINTAIN FIRE SPARE UNLESS BEING REUSED FOR NEW WORK; MAINTAIN ACCURATE PliUF MANAGER PRIOR TO DISPOSAL. RATING AND RECEIVE NEW FLOORING. COORDINATE WITH PROPERTY PANEL DIRECTORIES. ��Q PKU ESs� MANAGER, TENANT AND TELEPHONE COMPANY PRIOR TO DEMOLITION. /\� G%NFsq 0y 6. REMOVE THE DOOR CONTROL CARD ACCESS HARDWARE AND WIRING. F. ALL RACEWAYS RENDERED UNUSED AS A RESULT OF THIS PROJECT � 0� 9 COORDINATE WITH LANDLORD AND TENANT PRIOR TO REMOVAL. 17. DISCONNECT EXISTING VAV BOX FOR REMOVAL. BUT NOT CONCEALED WITHIN THE BUILDING CONSTRUCTION (WALLS Lk 79 ,33PE. AND SLABS) SHALL BE REMOVED. SURFACE AND RECESSED BOXES NO 7. REMOVE FLOOR BOX AND INFILL FLOOR TO MAINTAIN FIRE RATING AND 18. EXISTING POWER POLE AND ASSOCIATED WIRING AND CONDUIT SHALL LONGER USED SHALL BE REMOVED. PROVIDE BLANK COVERS FOR lr RECEIVE NEW FLOORING. BE REMOVED AND PROPERLY DISPOSED OF. RECESSED BOXES WHICH MUST REMAIN FOR SPLICING OF WIRING THAT :id,-!Moil 1 SERVE DEVICES AND FIXTURES WHICH REMAIN. ., 78 2- •‘- 8. � 8. REMOVE AND RELOCATE DIMMER SWITCHES. EXTEND WIRING TO NEW 19. EXISTING PROJECTOR SCREEN AND SWITCH SHALL BE CAREFULLY LOCATION. REMOVED FOR RELOCATION. COORDINATE WITH TENANT. G. PROVIDE ALL NECESSARY MATERIALS AND LABOR TO REROUTE ` EXISTING SERVICES IN ORDER TO MAINTAIN THE CONTINUITY OF kOp 9 '1 711hi 9. DISCONNECT EXISTING SPLIT SYSTEM FAN COIL AND ROOF MOUNTED EXISTING SYSTEMS OR CIRCUITS SERVING FIXTURES, DEVICES AND CONDENSING UNIT FOR REMOVAL. EQUIPMENT THAT REMAIN AFTER THE SCOPE OF DEMOLITION IS COMPLETE. W 10. REMOVE ABANDONED VOICE, DATA, SECURITY AND AIV CABLES IN WALLS AND ABOVE CEILINGS. COORDINATE WITH PROPERTY MANAGER. 0 1 "LIE 11. TENANT'S LOW VOLTAGE VOICE AND DATA WIRING SHALL BE PULLED O 1 1 [ 2 [10� 1.1.1Ck4' 2 1 2 3 4 5 � - J'� - 6 CT) 8 9 °0 0 0 0 00 0_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ."' ice_ Z 8 ao U _ _lit _� j j////` ;i iiiii�iiiii iiiiy//Iii%�i"' ii / i // i/ii i�iii</ ii i/,' �i/r//i iii/ ' ` 0 ® _ 1 . IT A "R1° ,IR111 eil ,1R11, 12 n 0 I rAgrrr 11 11 fl 11.% , �, / / / roorar 11R11, R1 R1 / �! / / 18 1:1=1c)s lio /. /.ION rIQ11, I,R1,1 I,RT,f IIR1,1 iGlr // ' / 7, ( (/ II% •� ;: (jam o❑ ,� 19LTJ 1,�, n LI:El n / ❑ / , i/ % "R1" ,18111•% ;4; 11R111 "R1"'% IVB Wyr , ' I,R1,1 ,,, „R1„ „R1., , `�'/ y' R2 R2 J IIp 111 9R 111 1,R111 IIR 111 % %,I �` 'IP wig '1', 'L, , ,1 �' ,! �I .� l�� l•.I !•% -•�R / .A,!<. ,. 4 ear.4 7. "I.! r arm aU �a/. n 1r u u u u e 11 , a S � -.� / G CD..., f a / 7 11 ,1 11 11 1, R1 % R1 R1 R1 IR1f, c� %r�� —7----=0. al L R11f / j I. or , v / ii ���❑ 13 r R1" R1 R1 / % r.;. — _____. ,-,),,/,.-_ / ,, , ,, , / / " - 11 11 11 If 11 1f //J, / / %4/. ❑ //..,// 1f 1, 11 "R1" ,1 11'. // - I R1 R1 RI "R1', / / / 11 % R1 % R11 % „R111 % 1R1� % 1811, R1 / r:% �i. Vii_ / ' Vii. // :jr //////,. /////,. //////.- ,�%, r• � �' , ��'�' �' ,l�7�/(�//�/yam— :/-'� � � � � ® � � � or,r, / , - ❑%,� '% %❑(TYP.) WIOW— �� __ - % 11R111 ate[ R1" 4, ..A, .•4 �� r,,,,., // 1 //� iT / 4:441 I C - : , , , / y` a//����/ / LIQ 1%'I, •;' '% "R1O '% 11p1u '� 1,I:]1H .�,% _�, �'.,% 7,y�pl�,y///� '% // 1 ./ J �/ % Ill // FRl �- �� II % ,//oo % % /Ir / ,, , , , DP / / �i 11 A / %, �. AI P� /,7 , �_ N +' '� n['f111 / ,1R111 11R111 /i . ...1 / ,/ , 1 �� !/I/!� r 4❑ PC�... Z O n B 1� 11 11 , w ' u ,' . i 0 I1 il j �r� t . z1,::PrIA / a� %/rrJ /R1 R, R1 ' %/��� % N „ % 11 ,1 / 1Wo13) --- � ' 485 R1 / ��r �� � / /I 4 /r ► \ �9 �fi, ❑ ” Yl 14C5" /� / r /r r • r - ,9L/ % % % , % / ~ 2B5A / , /a / / ��11 n ' u IIn• .� I/Ir % / -.',I� �ii'.�' � / / T2 In I I �� � i:•;,_., / / // A Z R1 R1" RT AA � / - / / "R1 / /C �. 13 I � / /I 0 �i / ❑ ' „R1" • / I //�+—! 1 �. IIR1�1 I,R1, IR11� =' /� �. 12B5B-1" 2A2A6" -��-� �� .::fir / , ' / /„ 1e., 1 R1 - /��� /f / / ❑ / Ir - / :}: '/, , 1 II 1 ii 1 /moi / 15 /i'/ /, %SII/ 00 ��.A.to S!I� , /_ e. I I � ` 1, ,1 /� o L-JL-J ❑ / I III,/+ „ „ , � „ > . . , , „h :rrr�Ei:� i `,'✓tel' . .' // / 1�% fl ` , '- H 1, ,�, u/., — N % 11p ilr % 11p111 I,p11,' , �� 11p11f % r`= .► ;•:4=` ,% �11p111 '% ,Ip111 '% '% , %3:�„Ip1R ✓. =Box ;-/R, r IZ 1 R Il R r / / _/)? ��++ \/ 1,. 11 F\ R ! �► fl / ! , , rl> "R1” / 13 j 11/x.111 IIR 111' ���, ��� /` - %. /i , ' �' / ' �� - O�,\I i % i , r• / / / / 'R1” / 'RT / 1 / / .. "R1” / / / ' .mac. 15 —, \rtf— a " 1//�e.��_i��I� �'`+ / [ //r�• 17 �� ; Ff GI■S c - EV .RM— 513 � d �/ //I� A9: voki/. • Iril �' ��� / ,,,,, , �� ❑ '�I/�� '1-* "" <���irr� g��Al� / / / r ////,7 . 5 \ CI ,,, t_c__.4 cir / 1 1\ j "RT" '; "R1" ;(// �.• ""„ /,FA r ,P 02", `% � I,p 11, J' I,p 111 v- ,l%M, % `r "R'I" 'J'l� ,1p11, If ,Ip 1,1•� '� �.. 'r 11['1111 -' I ' : 1 =4 . , ,/ / "R1" 1 11 / 11 11 / 6 / / / / 11 11 r/fr ' // , R1 / ,IR16 /' /' R1 /, �a s, R1 /, ❑ %%' /, /, ,;,,, /, / R1 / A / A� 4 A AA 0 7 /"rss.{��- 4,-,.., /'�' -��f f••— , n n n n 7)Ti n'z B� " 15 \ / � �s,,' ____5� ,,' 'J./� I ;1���� IN%._ tV / ///// //// r / „/ 19 .. ��..� �, is ' / f• 4❑ , }, 13'% �� R3' '��` ;;,o,r �" R3 j �' GO / ! ,/ R1 % r� ir 4•j ,._ ,� R3 "R3 "R3" "R3" ����.►1� I r or /I /1/ ��. ��R111 �i , 14 i i''' — is / (04, :f 7 0!� Q 17 / ^yryJ�yyyy,/ ��3i'.., %��p//�{yp�y(.//� {� ✓/. 'r�� % / j R1 V R1 _t -• / ��� %moi., Z LJ'�4: f, , ' / /, rail 1Ip�]I� El:. 1 �,1 "R311 1,p�11 O /�J /4J , n o n n n .�:':% —t., ;% �� �,j�!�: ®� , `% "" """ /, "R3" /' � r\.J II Il 1-r iJ , II fl Il fl 11 11 If 11 !1 (Ds �/ �� 1� �1llll / R18 y R1 R1 R1 % "R1" "R1" "R1" `.�; ❑� k7: r �•' A: :44 �i / CL E ������`�,or/ 04 �S � ��;;✓, �4., � R3" �,Y 11R311� �, � 11R311 7/IY:k "R3" 183 � ���' '�y� R3 -� _.J I ?l/s�, c, -12- i A 4%'7.- %�/'• TYP. � iii-�� ❑{TYP.) / �I�/i/f 1f1y 11, "RI" 11p 11, 11R 111 rrrr� I / I / TOEMP,Zer/_ r' ///// rrr'. 11 ./ , „ , , /O/ / ii If ,1 % , '�� i , ' // "R311 15'1 "R3" r "R3" R3" "R3" R3 % , %C / I1 P /, I e4 ...I„, ., .,A ,A , A r.'0. r , ' / , 11p 01� 11p3H j ' ./ /r .. 1�I. I/7 liI "/ I gA.J%/ / /7/140dor, -r I r /mo�i� IIA 11 "R1” / ,IIR311 / / �i'lj� 11pq,1 , ,.�,./, / RI,R3, �� OS x 11Av.•.. ,.1 ry /C ►i7f' I.may. 41# I . ✓• „r, „ r ,, , ,,, ,ri rr T / a U „ ►!. ` FM 7T , . ! 'ri//i' / i/,. i/%ii,iiiii'_/, t���i/� i i/ y i r�iiiii�� �IL`ii/ • A/ Ay/. � ir yr f 0 A'11 11,.,777 1 ,, ,, ' �i/i/ iii//!J.i// '/.'/1Y/ if/iiiiii jiiiii (////.Giii/ i' / /�/i /ii • LLI �i �� �� R3 R/or le3 F� % r G. J i „ D,,,,„. ,. A ' -i - I ' ", -ic<>T70- r "R3" 7 ,,D„, 1/ r r 4 - -- 1Ir/ • - —11121101 I� ' d� 011 \-.1(1-\/* 5 V ' %, C` ,'Y j' I� Tl / J j I'1.7 , ., ,(TYP. DATE 05/23/2018 N ./.11-7,1 .7.</. 1 < ►- ����/,,,`f� ',�i 1. `�� _ _ _ _ _ SCALE a:: MGR JOB 41 PARTIAL FIFTH FLOOR PLAN - ELECTRICAL DEMOLITION SHEET N \161 SCALE: 118" = 1'-0" E 2 1 OF SHEETS IT: DESIGN HEREBI EXPRESSLY RESERVES RS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IIT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMI1SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT 1 I I I a) REVISIONS BY I Hog N r • fl PLAN NOTES - POWER & SYSTEMS GENERAL NOTES r.:8 � -- � c5. u.� pC o N ca ^ (NOT ALL PLAN NOTES WILL APPLY TO THIS SHEET) A. CIRCUIT NUMBER FOR EXISTING PANELS ARE SHOWN FOR REFERENCE O < a d v ONLY. VERIFY AVAILABLE CIRCUITS AFTER DEMOLITION. PROVIDE NEW i^_ Z �O m c4 1. J.B. FOR POWER CONNECTION TO MODULAR FURNITURE WHIP. 6. J.B. FOR POWER CONNECTION TO RELOCATED CEILING MOUNTED 14. EXISTING POWER SHALL REMAIN IN THIS AREA UON. MAINTAIN CIRCUIT BREAKERS AS NEEDED. VERIFY PANEL LOADING PRIOR TO 0 F D Z W • PROVIDE STAINLESS STEEL COVER PLATE WITH 90° CONDUIT FITTING MOTORIZED SCREEN. CONNECT SCREEN COMPLETE AND READY FOR CONTINUITY OF EXISTING CIRCUITS. CONNECTING NEW CIRCUITS TO ENSURE NEW CIRCUITS WILL NOT (, c Z Ca {g FOR WHIP CONNECTION. POWER WHIP PROVIDED BY TENANT OPERATION PER MANUFACTURER'S INSTALLATION DIAGRAMS AND OVERLOAD PANEL. tj w Z 7 INSTALLED BY ELECTRICAL CONTRACTOR. MODULAR FURNITURE INSTRUCTIONS. A/V EQUIPMENT ARRIVES ON SITE AFTER TENANT 15. FUSIBLE DISCONNECT SWITCH FOR VAV UNIT PROVIDED WITH UNIT BY z y O {p RECEPTACLES, AND TASK LIGHT WILL BE PROVIDED AND INSTALLED BY OCCUPIES SUITE. M.C. FUSES PROVIDED BY E.C. COORDINATE INSTALLATION WITH M.C. B. CUT AND PATCH WALLS AS REQUIRED TO INSTALL NEW FLUSH BOXES CkiLijZ re FURNITURE EQUIPMENT SUPPLIER (DEVICES NOT SHOWN FOR CLARITY) AND CONDUIT IN EXISTING WALLS. w u < w UNLESS LOCAL CODE REQUIRES THAT THE EC INSTALL THE 7. PROVIDE ROUGH-IN ABOVE CEILING FOR RELOCATED SWITCH 16. WALL BRACKET MOUNTED TV MONITOR BY OTHERS. LOCATE DEVICES Z c0C Q V = RECEPTACLES. A MAXIMUM OF FOUR CUBICLES CAN BE CONNECTED TO PROVIDED WITH SCREEN FOR MOTORIZED SCREEN CONTROL. APPROXIMATELY 8'-6"AFF. COORDINATE RECEPTACLE AND DATA C. AT LOCATIONS WHERE A PHONE/DATA ROUGH-IN IS SHOWN ADJACENT h G n n c o A CIRCUIT. COORDINATE INSTALLATION REQUIREMENTS AND WHIP CONNECT PER SCREEN MANUFACTURER'S INSTALLATION DIAGRAMS LOCATIONS WITH BRACKET AND MONITOR TEMPLATES FOR PLACEMENT TO AN EXISTING RECEPTACLE, THE ROUGH-IN SHALL BE AT SAME Z - o M H p r,"; v LOCATION WITH TENANT/PROJECT MANAGER PRIOR TO ROUGH-IN. CUT AND INSTRUCTIONS. COORDINATE INSTALLATION WITH TENANT. AN BEHIND MONITOR. HEIGHT AS EXISTING DEVICE. w ¢ c U o AND PATCH WALLS FOR A FLUSH BOX AND CONCEALED CONDUIT EQUIPMENT ARRIVES ON SITE AFTER TENANT OCCUPIES SUITE. Z Q N INSTALLATION. 17. CONNECT TO EXISTING CIRCUIT SERVING CUBICLES. D. AT LOCATIONS WHERE THE WALL OR COLUMN DOES NOT HAVE � Z o ^V^ 1 E' °7 `n° 2 6 8. PROVIDE SINGLE-GANG DEVICE BOX MOUNTED AT 18"AFF TO CENTER SUFFICIENT DEPTH TO RECESS THE DEVICE BOX, JUNCTION BOX OR Q V/ 2. PROVIDE J.B. WITH CONDUIT(S) TO ABOVE CEILING SPACE PER DETAIL WITH PULL STRING IN WALL FROM DEVICE LOCATION TO ABOVE RACEWAY DUE TO STRUCTURE OR MASONRY, PROVIDE A WIREMOLD p) °C n n a°i 6/E-101 FOR ROUTING OF CUBICLE DATA AND VOICE CABLES. ACCESSIBLE CEILING FOR A/V INPUT PLATE (EXTENDER TX). AN INPUT 4000 DIVIDED RACEWAY FROM NEARBY WALL OR CEILING. RACEWAY , CJ FF - COORDINATE INSTALLATION REQUIREMENTS WITH TENANT/PROJECT PLATE (EXTENDER TX)AND CABLING SHALL BE FURNISHED AND SHALL BE PAINTED TO MATCH WALL OR AS DIRECTED BY ARCHITECT. U I -414-?; o MANAGER AND FURNITURE SUPPLIER. CUT AND PATCH WALLS FOR A INSTALLED BY TENANT. REVIEW EACH LOCATION WITH ARCHITECT/ENGINEER PRIOR TO J FLUSH BOX AND CONCEALED CONDUIT INSTALLATION. PROCEEDING WITH WORK. z a a 9. PROVIDE SINGLE-GANG DEVICE BOX MOUNTED AT 4'-0"AFF TO TOP OF L U 0 ,_ ,,_ g o 3. PROVIDE FLUSH. FURNITURE FEED POKE-THRU FLOOR BOX, FOR DEVICE WITH PULL STRING IN WALL FROM DEVICE LOCATION TO ABOVE Q o 0 CONNECTION TO SYSTEM FURNITURE, SEE DETAIL 5/E-101. MODULAR ACCESSIBLE CEILING FOR KEYPAD. KEYPAD AND CABLING SHALL BE - ■ - z FURNITURE RECEPTACLES, AND TASK LIGHT WILL BE PROVIDED AND FURNISHED AND INSTALLED BY TENANT. �� INSTALLED BY FURNITURE EQUIPMENT SUPPLIER (DEVICES NOT SHOWN �P� FS'S FOR CLARITY) UNLESS LOCAL CODE REQUIRES THAT THE EC INSTALL 10- DO NOT INSTALL D.R. BEHIND COFFEE MAKER AND ICE/WATER ��� �NGINEFR �O ca THE RECEPTACLES. A MAXIMUM OF FOUR CUBICLES CAN BE DISPENSER. EQUIPMENT WILL NOT BE MOVEABLE WITHOUT � CONNECTED TO A CIRCUIT. COORDINATE INSTALLATION DISCONNECTING WATER LINES. REFER TO ARCHITECTURAL DRAWINGS. 7',53 PE REQUIREMENTS AND CORE DRILL LOCATION WITH TENANT'S FURNITURE • VENDOR PRIOR TO ROUGH-IN. COORDINATE CORE DRILL WITH TENANT 11 PROVIDE DISCONNECT SWITCH AND CONNECT INSTANTANEOUS WATER A,f1° i BELOW. HEATER COMPLETE AND READY FOR OPERATION. COORDINATE WITH „• isN� 4(1 4. 8,24� 4. STUB UP EMPTY DATA CONDUIT WITH PULL STRING TO ABOVE CEILING. • ` GR\ CONDUIT SIZED PER 61E-101. 12. PROVIDE RECEPTACLE IN SINK BASE FOR FLOODMASTER AUTOMATIC WATER SHUT OFF VALVE. COORDINATE WITH P.C. 1i by 2018 5. PROVIDE TWO RACO#420 DEVICE BOXES, TWO WHITE DUPLEX RECEPTACLES AND FACEPLATE FOR MOUNTING INTO TENANT 13. PROVIDE A NEW TYPEWRITTEN PANEL DIRECTORY AFTER COMPLETION W FURNISHED LAY-IN CEILING PROJECTOR MOUNT. LOCATE OF PROJECT REFLECTING ANY CIRCUIT CHANGES. FOR EXISTING APPROXIMATELY 8'-10" TO 13'-6" FROM SCREEN. INSTALL PER LOADS, OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY, MANUFACTURER'S INSTRUCTIONS AND COORDINATE INSTALLATION BUILDING ENGINEER OR TRACE OUT LOADS. 18 WITH PROJECTOR EQUIPMENT SUPPLIER AND G.C. AN EQUIPMENT Liilh Q " ARRIVES ON SITE AFTER TENANT OCCUPIES SUITE. Z� o W� 2 ED 0 0 0 0 ��---- - --�- ......,______,________.0 o o limo O. 1 2 1 2 1 2 1 © 1 oZ 8 11e, e(E) r n LlJ LTJ Lam] fE)V v ry(E1 (EI 70/0/ ` 1// %// j/ j 4IUU# # . 7(((((/7 // //� �I / - V A {Ey�G J (EI {E)v� I �I(E} I (E) - (1/. 7. . C ���/ !(�( ( / ; _= 0 0 7 _ I7 fE) ,..� (E) �� 1i) OFFICE 14ll t----1 A,--7....7. lei /'• 265 2426 : 2B5 32 I i265C-23,25 1 ] 2B5 2830 �1• == lialaaari pip II- (E)OF 7) {E) _, ov • ---- _ 7,- I imm ® �-- owl awii _ J L J L J HOTEL COLLA>30 TIIJI�E 502 n �� ` .1/ e / J / j / rt/ mlrl► • 1r[75 in (E) C oolIIIM, . . IET......T-a ��� G, , CONF. 2 V-.- 7171- 7 1 , ., Zia Mr ____ r ❑ _.= ► - I I I I CIONF. 1 , ►s r / /. A / i LL,..... . �7] Lam] �� I B5 25,27,29 ■ ■ ��/J 2- . ✓ 1 1-- --_ IN.L.Li_, n , . l[n] 4 �r rr r✓'Cdi 2A5-14.1$ rs OFFICE 13 I I 10 r- 7 531 _ 41:,(E) rA� / -- - --- 10 icl o^ 2B5C-7 _ _ © ++� /7/ , OPEN OFFICE 4 2B5c 10 I ,�A 2A5-10 FES -_ �� ��% /7//:// j FE 533 10 15 © 2B5-34 i'% Ail - C' E-1 5 0 10w yy1Q 74D f FE (Ey � ������ i���� '�; 1_ .' II �b (E)CD /°�/I (-J / ,� �" �� z d HUDDLE I LIDDLE 2 +CUDDLE 3 t L�� ,, / , , / . ,/ , ,/, 0?:: --1 elf/*/ �,. -.,:I /���►- / ,�� �►�I wo B _ a! _ G I P�IONE �` , �i ,or 1� I:'rig ;: ;�'I /Ijrf �I. � ;� lo OFFICE 12 2B5c-6 MQ o d 1Eio , d CM 7c_ . 7 �// / 4 / �� / - �1/� _!� � • 530 10 7 ! 0© / �/ 'DP" .� �� / loor!F � , / ��/ 5i I 5�: 2B5c 2_ 10 j� � / �� / r , / % ,,..6,. I/ „ ! 1 ... O 6 (�• I tl Ijr t� 1� ` �1 / �", / 1 ,r�I �1 1 ,f 1TI �. #(.44.) STo2. - 7 �� * .//H:11"412.' EQ�IP. - /. : r.: r// % �.�..-, /.�.A..„ 4! W O / e(+ 4) 5A __:-vg- '�� � / /�"4B5" , ' 'I f 0 re 6 • 5 / /P - -\-1 fr,,.--- "2B5A" ❑ /y / I // ►�I y/ � / 13 n I /. / I I l ` Iz Z (E) .._J /II////,II/ /� riL 7 / ��,��� / NETWORK / .1 ,:'.� .;' �7 /%G��/,� �7� .!� 5 � PRIN -���% / .. { 7� � 'ri '"zB5° 14 r �r_ �r.�- �� iI ------ --� / 534 A�r / r j✓, 7 /I .�-i, 5o4a �f 1 i.�L W a F d Immo r . .� rr 4.0171:� �r,. '„zB56 1" "2Az 413" III / y r ,,/,/I �� G/��//. ,. ; 265-7 �, i r :. e I / ,/ 0��` v I dIICC 1= II_0 IC _ ___.I _ ��i. r ���// ,.', ,,� .* iii 'cii'i A5 0 - I /% i /� ./. 0 ri a �© �_ IO I! I I I (E)FIII ---tr ! �..J , . . „ {E)0ao � o a oI _ � i, i �, . 1iI2 �171 . ,�� OTHERS 1 •� i ����` �/\, NON-RATED CORRIDOR 1 1 I2I17� 5 2B5c 8Ll\ - ROOM � __ /' e I �,E-302 / tv, �� / JAN, (E) / t 7 cp .51-,.--' C • / : cIllr 111 / I �% 2B5A-15 E E O 2B5�-12 �� �� / 1 ��,�.�► O QD 15 O QP 1 ,w / 2B5G19,21 2B5c 5 15A ❑ OPEN OFFICE 3 I / • n1 - © © PE 1\ 4135-39,40,4 -1 5 216 LTl 1�l 1RPOSE_ 8 2B5A 41 41 265 6,8 ///1 1 I I 522 , It i' 4.... _ IJ 2B5c 41 41 (E) 15 4. IMI - ii {+�„) UT15A LA, O cii J Zi'' _ _ �� �� J/ 2B5 18,20,22 13 [+""� il 15 r /' - /// / /./ / //./ ,I. I I 00 li II 0 ail _ I il [ I 1 ©c �9 5-16 ❑ © / 'V///l j 1 2 I - I I I Asa p 15 ® O / Z I, 15 - I I I I �I �I I (1 I �� I 2B5A 29 TRAININGi�00�'1 j / lif Y 523 l/. .<;.._ f A,'' / /, ...71_ C t•7, l5[_, C C I- r 0 / Ili mi I I I n _ CC ,° I 1., - -<>-\4. /Or /AI Air N / 541 / w 2B5A-31 2B5A-17 BREAK /7nr-v- 1 2B5C-15,17 g / I4' I■I I�I di 11..'1. �1 522 (E) / - -- g 2B5c 3 / I I l �I Q =L .,A-a...T- 1 1 �33 2135A-19 REF r) C 3 1� �4.._... r . 1 / _ 3� 2B5c-1 L _.... ' �,- r , / [ 1,. L - 5 OFFICE 11 - 1- 1 _ 37 I i , ,flim 6 1 it // i/ i , iii I 1arr . I I { ,i' 0 - _ 52gAi / .1 �- I, fI s - - Ai - �� 3 �: '' %" rte -,' ..!.4.r � ' ia/� 5352B5A-21� I �1�� 1''.��� r/ Z -/ L Z 1,3 ° C f du i ��yf r+r . i. '71.1(0 -A151.: `r „/ :1 1.- -1 si is I 2 ' ,mo Pr i, / j • /arAy LQ ,_ / i /// �y-,� ,,:./ . , IILI H Ig;;;77,077:, .41 Fr / .7.,thwirtF14: ail n . - I I 'upmmamilFtil tll'1A* -1 117--iii-i 'iPii E-302 ,. / CC ! .rte.. AZ, „ /./ .1 41 1111 //// /4//‘-1-1C7// _ _ , 'li w/„ - p _ a Lir i 4 III ii �I lir.: , Nut I .... r-,:li m ,4 _ ME .` .40,- -<> cc 0Q CL / +�'I 1t,rr� `rR _ 2; A-39 T� 2B5A-25 �� • �-' LLL1 J ,41, I �\ �Y 00 , 1 I I ! I / \ I ii II�1 A15 T �// �� : 39 / \ 1-� REF I� ` ) . _Air . �A -1 ___- I I -- I / \ t - ' . / Al J 3t I 11 / \ 2B5A-27 -� DATE 05/23/2018 _�_ SCALE`` �� \ O c (Ey X1141 -` AS NOTED CO CI CD Q © 9 ' --f ;1 1�� . 0 o ® ® MGR JRA U 6 JOB CEN014 SHEET PARTIAL FIFTH FLOOR PLAN - POWER AND SYSTEMS N SCALE: 1/8" = 1'-0" E-301 OF SHEETS IHDL DESIGN HEREB"EXPRESSLY RESERVES ITS COMMON LAW COPYR4GHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRffTEN PERRMI1SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I w REVISIONS BY i~ � o N o ❑ PLAN NOTES - POWER & SYSTEMS GENERAL NOTES o 6 (NOT ALL PLAN NOTES WILL APPLY TO THIS SHEET) A. CIRCUIT NUMBER FOR EXISTING PANELS ARE SHOWN FOR REFERENCE O < p Z a ONLY. VERIFY AVAILABLE CIRCUITS AFTER DEMOLITION. PROVIDE NEW - w c 1. J.B. FOR POWER CONNECTION TO MODULAR FURNITURE WHIP. 6. J.B. FOR POWER CONNECTION TO RELOCATED CEILING MOUNTED 14. EXISTING POWER SHALL REMAIN IN THIS AREA UON. MAINTAIN CIRCUIT BREAKERS AS NEEDED. VERIFY PANEL LOADING PRIOR TO Qtz) m H `r, Z W PROVIDE STAINLESS STEEL COVER PLATE WITH 90° CONDUIT FITTING MOTORIZED SCREEN. CONNECT SCREEN COMPLETE AND READY FOR CONTINUITY OF EXISTING CIRCUITS. CONNECTING NEW CIRCUITS TO ENSURE NEW CIRCUITS WILL NOT U Z Cj FOR WHIP CONNECTION. POWER WHIP PROVIDED BY TENANT OPERATION PER MANUFACTURER'S INSTALLATION DIAGRAMS AND OVERLOAD PANEL. • w Z Z_ INSTALLED BY ELECTRICAL CONTRACTOR. MODULAR FURNITURE INSTRUCTIONS, AN EQUIPMENT ARRIVES ON SITE AFTER TENANT 15. FUSIBLE DISCONNECT SWITCH FOR VAV UNIT PROVIDED WITH UNIT BY Z '„ >-' 15 > CO RECEPTACLES, AND TASK LIGHT WILL BE PROVIDED AND INSTALLED BY OCCUPIES SUITE. M.C. FUSES PROVIDED BY E.C. COORDINATE INSTALLATION WITH M.C. B. CUT AND PATCH WALLS AS REQUIRED TO INSTALL NEW FLUSH BOXES FURNITURE EQUIPMENT SUPPLIER (DEVICES NOT SHOWN FOR CLARITY) AND CONDUIT IN EXISTING WALLS. Cie w i d ¢ u1 UNLESS LOCAL CODE REQUIRES THAT THE EC INSTALL THE 7. PROVIDE ROUGH-IN ABOVE CEILING FOR RELOCATED SWITCH 16. WALL BRACKET MOUNTED TV MONITOR BY OTHERS. LOCATE DEVICES 0 Q v RECEPTACLES. A MAXIMUM OF FOUR CUBICLES CAN BE CONNECTED TO PROVIDED WITH SCREEN FOR MOTORIZED SCREEN CONTROL. APPROXIMATELY 8'-6"AFF. COORDINATE RECEPTACLE AND DATA C. AT LOCATIONS WHERE A PHONE/DATA ROUGH-IN IS SHOWN ADJACENT - V D C 0 A CIRCUIT. COORDINATE INSTALLATION REQUIREMENTS AND WHIP CONNECT PER SCREEN MANUFACTURER'S INSTALLATION DIAGRAMS LOCATIONS WITH BRACKET AND MONITOR TEMPLATES FOR PLACEMENT TO AN EXISTING RECEPTACLE, THE ROUGH-IN SHALL BE AT SAMEd LOCATION WITH TENANT/PROJECT MANAGER PRIOR TO ROUGH-IN. CUT AND INSTRUCTIONS. COORDINATE INSTALLATION WITH TENANT. AN BEHIND MONITOR. HEIGHT AS EXISTING DEVICE. 1-LI ¢ 6.4 S a II: O a AND PATCH WALLS FOR A FLUSH BOX AND CONCEALED CONDUIT EQUIPMENT ARRIVES ON SITE AFTER TENANT OCCUPIES SUITE. Z Fa- 0.2 INSTALLATION. 17. CONNECT TO EXISTING CIRCUIT SERVING CUBICLES. D. AT LOCATIONS WHERE THE WALL OR COLUMN DOES NOT HAVE M ZO ^ d `,, of 8. PROVIDE SINGLE-GANG DEVICE BOX MOUNTED AT 18"AFF TO CENTER SUFFICIENT DEPTH TO RECESS THE DEVICE BOX, JUNCTION BOX OR U W Tel 2. PROVIDE J.B. WITH CONDUIT(S) TO ABOVE CEILING SPACE PER DETAIL WITH PULL STRING IN WALL FROM DEVICE LOCATION TO ABOVE RACEWAY DUE TO STRUCTURE OR MASONRY, PROVIDE A WIREMOLD2 �` N N. y 6/ E-101 FOR ROUTING OF CUBICLE DATA AND VOICE CABLES. ACCESSIBLE CEILING FOR A/V INPUT PLATE (EXTENDER TX). A/V INPUT 4000 DIVIDED RACEWAY FROM NEARBY WALL OR CEILING. RACEWAY tj u3 w - COORDINATE INSTALLATION REQUIREMENTS WITH TENANT/PROJECT PLATE (EXTENDER TX)AND CABLING SHALL BE FURNISHED AND SHALL BE PAINTED TO MATCH WALL OR AS DIRECTED BY ARCHITECT. urnrn T o MANAGER AND FURNITURE SUPPLIER. CUT AND PATCH WALLS FOR A INSTALLED BY TENANT. REVIEW EACH LOCATION WITH ARCHITECT/ENGINEER PRIOR TO .J N > v . FLUSH BOX AND CONCEALED CONDUIT INSTALLATION. PROCEEDING WITH WORK. V A, E 8 9. PROVIDE SINGLE-GANG DEVICE BOX MOUNTED AT 4'-0"AFF TO TOP OF L � 3. PROVIDE FLUSH, FURNITURE FEED POKE-THRU FLOOR BOX, FOR DEVICE WITH PULL STRING IN WALL FROM DEVICE LOCATION TO ABOVE .n Q 2 v CONNECTION TO SYSTEM FURNITURE, SEE DETAIL 5/E-101. MODULAR ACCESSIBLE CEILING FOR KEYPAD. KEYPAD AND CABLING SHALL BE ■ - v L FURNITURE RECEPTACLES, AND TASK LIGHT WILL BE PROVIDED AND FURNISHED AND INSTALLED BY TENANT PROF INSTALLED BY FURNITURE EQUIPMENT SUPPLIER (DEVICES NOT SHOWN DQE ESS FOR CLARITY) UNLESS LOCAL CODE REQUIRES THAT THE EC INSTALL 10. DO NOT INSTALL D.R. BEHIND COFFEE MAKER AND ICE/WATER �c� c't•\- Fq ci THE RECEPTACLES. A MAXIMUM OF FOUR CUBICLES CAN BE DISPENSER. EQUIPMENT WILL NOT BE MOVEABLE WITHOUT CONNECTED TO A CIRCUIT. COORDINATE INSTALLATION DISCONNECTING WATER LINES. REFER TO ARCHITECTURAL DRAWINGS. Q 7'53 °E- REQUIREMENTS EREQUIREMENTS AND CORE DRILL LOCATION WITH TENANT'S FURNITURE VENDOR PRIOR TO ROUGH-IN. COORDINATE CORE DRILL WITH TENANT 11, PROVIDE DISCONNECT SWITCH AND CONNECT INSTANTANEOUS WATER It. BELOW. HEATER COMPLETE AND READY FOR OPERATION. COORDINATE WITH ply �•o� �� P.C. �l� 8,20 4. STUB UP EMPTY DATA CONDUIT WITH PULL STRING TO ABOVE CEILING. ..CONDUIT SIZED PER 6/E-101. 12. PROVIDE RECEPTACLE IN SINK BASE FOR FLOODMASTER AUTOMATIC 1 1 - 2013 WATER SHUT OFF VALVE. COORDINATE WITH P.G. 5. PROVIDE TWO RACO#420 DEVICE BOXES, TWO WHITE DUPLEX RECEPTACLES AND FACEPLATE FOR MOUNTING INTO TENANT 13. PROVIDE A NEW TYPEWRITTEN PANEL DIRECTORY AFTER COMPLETION W FURNISHED LAY-IN CEILING PROJECTOR MOUNT. LOCATE OF PROJECT REFLECTING ANY CIRCUIT CHANGES. FOR EXISTING W APPROXIMATELY 8'-10"TO 13'-6" FROM SCREEN. INSTALL PER LOADS, OBTAIN DESCRIPTION FROM EXISTING PANEL DIRECTORY, MANUFACTURER'S INSTRUCTIONS AND COORDINATE INSTALLATION BUILDING ENGINEER OR TRACE OUT LOADS. ig2(zsWITH PROJECTOR EQUIPMENT SUPPLIER AND G.C. AN EQUIPMENTQ ARRIVES ON SITE AFTER TENANT OCCUPIES SUITE. KC-04" � 0 Wo 2 Z § § W (1 - 0 r m 1 I §I i ._ ,, , . _ _.41-rlii 2B A-8 ri �-. 2 � ZLE � - - 2B5A-2 �= l!L 7,-711.1,r. 2BSA-28 (+44") : Z2B5A-4 -FW aF 2BSA-30 310 _ O 010 2B5A-32O aF I 1 V , / , , , , , 1� , — I I # IJLIR MOTNER S �' 4C5 362BSA 6 W�l- ROOM - id CV 4C5-34 54m 11 2B5A-26 15;1 ?.-----1-11-41' 11 I (E) 2B5A-36 (+441 BRE,4K - 1I . __' 2B5-11 '■' [ / —. 22X - u - (-4") I / ..--,r Eir 2135A-344 -9 9 1 - I ac O 0-- IIL 1 ENLARGED MOTHERS ROOM 2 ENLARGED BREAK ROOM Co E-302 SCALE: 114" = 11-0" E-302 SCALE: 114" = 1'-0" Z o W 0 g2 121 Z Z wQ DATE 05/23/2018 SCALE AS NOTED MGR JRA JOB CENO14 SHEET E -302 OF SHEETS ' HDL DESIGN HEREBY'EXPRESSLY RESERVES n-s COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I cn REVISIONS BY H � o N # PLAN NOTES - LIGHTING GENERAL NOTES ° Roo°° H o :J4 6U. II. 1. EMERGENCY BALLAST SHALL BE CONNECTED TO UNSWITCHED A. THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING oCm `\' (3 LIGHTING CIRCUIT SERVING THIS AREA. RETROFIT AN EXISTING CONDITIONS. CONTRACTOR SHALL REQUEST CLARIFICATION TO ANY n ¢ =. ,2 Z O � FIXTURE OR FURNISH A NEW FIXTURE WITH BODINE B30 OR EQUAL DISCREPANCIES IN THE EXISTING DEVICES OR EQUIPMENT INDICATED ¢ w tr EMERGENCY BALLAST WIRED FOR 2-LAMP EMERGENCY OPERATION. ON THESE CONTRACT DOCUMENTS PRIOR TO BID. O N `s Z W SEE DETAIL 4/E-101 FOR EMERGENCY BALLAST WIRING. FIXTURES U vWMINNINIII SHALL BE SWITCHED UNLESS DESIGNATED AS "NL". INDICATE ON THE B. PROVIDE AN UNSWITCHED BRANCH CIRCUIT CONNECTION TO FIXTURES C7 ♦ W Z PANEL DIRECTORY THAT THE CIRCUIT SERVES EMERGENCY LIGHTING. WITH AN EMERGENCY BALLAST, TO EMERGENCY, AND TO EXIT Z r O W FIXTURES. CONNECTION SHALL BE TO THE SAME BRANCH CIRCUIT 04w '- z CC 2 NEW, EXISTING OR RELOCATED 277V. LIGHT FIXTURES AS INDICATED. SERVING THE LIGHT FIXTURES IN AREA AHEAD OF ANY CONTROLS '�' < W CONTRACTOR SHALL CIRCUIT FIXTURES TO ACHIEVE INDICATED REFER TO DETAILS FOR EMERGENCY BALLAST WIRING. FIXTURES 2 ig G i r- U N o SWITCHING. MODIFY WIRING AS REQUIRED AND CONNECT FIXTURES SHALL BE SWITCHED UNLESS DENOTED "NL". V Z i Q. TO EXISTING CIRCUITS PREVIOUSLY SERVING LIGHTING IN THIS AREA. Z S 0 O o VERIFY CIRCUIT LOADING PRIOR TO CONNECTING. C. PROVIDE AN UNSWITCHED BRANCH CIRCUIT CONNECTION TO FIXTURES ti.) ¢ 01:: •— N Q co co DENOTED "NL" FOR NIGHT LIGHT OPERATION. REVIEW AND CONFIRM Z (f) z v , 3 EXIT LIGHTS SHALL BE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT FIXTURES SELECTED FOR NIGHT LIGHT OPERATION WITH OWNER AND72 p • yo L SERVING THIS AREA. COORDINATE PLACEMENT AND ORIENTATION ARCHITECT PRIOR TO CONSTRUCTION. 0 U °y a n N. o WITH LOCAL AHJ. PROVIDE PROPER FIXTURE SUPPORT. INDICATE ON Q a� THE PANEL DIRECTORY THAT THE CIRCUIT SERVES EXIT LIGHTING. D. FIELD CONFIGURE UNIVERSAL EXIT SIGN DIRECTIONAL CHEVRONS, `O `° _• � V FACES, AND MOUNTING PER PLAN. U t -T.-T.- 4. %0%4. RELOCATED DIMMER SWITCH(S). EXTEND EXISTING SWITCH WIRING TO J > a NEW SWITCH LOCATIONS. E. EXISTING MULTIWIRE LIGHTING BRANCH CIRCUITS TO REMAIN. a i 6 a i {rr�rr - d -a 5. EXISTING LIGHTING SHALL BE MAINTAINED IN THIS AREA UON. MAINTAIN F. PROVIDE A GROUNDED CONDUCTOR (NEUTRAL)AT SWITCH OUTLETS Z v a CONTINUITY OF EXISTING CIRCUITS AND SWITCHING. FOR FUTURE CONTROL CAPACITY. s U - .c F„. ... r )r S,s/ 6. EMERGENCY DRIVER SHALL BE CONNECTED TO UNSWITCHED LIGHTING G PRIOR TO START OF CONSTRUCTION, COORDINATE ROUGH-IN �'\ ��GIN EFR O CIRCUIT SERVING THIS AREA. SEE DETAIL 13/E-101 FOR EMERGENCY LOCATIONS FOR SWITCHES WITH ARCHITECT. c. '' DRIVER WIRING. FIXTURES SHALL BE SWITCHED UNLESS DESIGNATED ¢ -lg. 33PE AS "NL". INDICATE ON THE PANEL DIRECTORY THAT THE CIRCUIT H. OCCUPANCY SENSORS & RELAY-POWER PACKS: THE SENSOR I ✓ SERVES EMERGENCY LIGHTING. RELAY-POWER PACK REQUIRES AN UNSWITCHED BRANCH CIRCUIT ' CONNECTION. THE OUTPUT OF THE RELAY POWER PACK IS WIRED TO ! ' 4 7 PROVIDE COOPER DEVINE MODEL"DF1OP" 0-10V LED DIMMER, MATCH THE ROOM LIGHT SWITCH. REFER TO OCCUPANCY SENSOR WIRING 'Alt ,�po1 SPECIFIED WIRING DEVICE FINISH. DIMMED FIXTURES REQUIRE DIAGRAMS FOR DETAILS. PZ-- ASF' SWITCHED LINE VOLTAGE CONNECTION AND 0-10V LOW VOLTAGE •. GRA CONNECTION. PROVIDE AWG 22/2 PLENUM RATED CABLE FOR 0-10V I. FIELD VERIFY EXISTING LIGHTING BRANCH CIRCUITS AND FIXTURES MAY2 3 2,r)1 WIRING CONNECTION. SERVED. UPON COMPLETION OF WORK, E.C. SHALL VERIFY ALL NEW AND MODIFIED PANELBOARD BRANCH CIRCUITING, AND SHALL PROVIDE 8. CONNECT LIGHT FIXTURE TO EXISTING OPEN OFFICE LIGHTING CIRCUIT NEW UPDATED TYPEWRITTEN CIRCUIT DIRECTORY CARDS. VERIFY W THAT MEASURED AMPERAGE OF LIGHTING BRANCH CIRCUITS DOES NOT i EXCEED 16 AMPS. o pp' 8 T( r z. .::.; m 0 JO ® z70 49 -------- ----1- --2‘ — ___________!„,,0 ® ® q � o o m J a iii Uj Q n111—R1F-- 'R2 R2 j/ % r i/iiir i r / itiiir� l ���/t/ f ` ■%-O �t 1�-� E4 „ 1R1 R1 R1 R1 R1 R1 R1 - AI R1 m En ...0,__ID P ° p �_ ��i�� / / //� / ■ i/ r / >� / 5: 2 JV V Y V � V V �_ V � V � V (E) N���L 2, GO1.L ICNe-A/ .. R1 R1 0 5m 5Q�1� . / .' ./(///A/ A ' /1 dd 'R2" R2" ❑ 5 i';"�' _.. 7".1 ._____...41 (EI (E) (E) IE) C (E) 4 O)�I J•A. r / P Ifl �j //li/I R1 R1 R1 R1 R1 R1 R1 R1 R1 ]�Tp En �_p �p �-p 1 rj-F ;- 1 R1 R1y2�OPN OFFIG_ z. Yr I ,� / `� %.E. y 73� ® 4 (E) Ie} iE} R1 `Ji �� ,,,,,,. / , //.: (E) ' �'R 11"Ri , „R 1 1 ARir id."/ n m A �n �p o p n z X / ;�SIG 11I lR1 R1 R1 R1 R1 R1_� n v „ y 1 J v _Q__V n ❑ NL �V _g_ v v ” p n •--- z �z ae1 R1 / i�.2 �� _>D 1 2 �UCDL� _ 1 �? //I r ,�.4 I4,1 i�..� I•.. nQ'- ICE 12 Del„X„ 1] — nNIID LE 2 � X„Ieln „R1 , „� �/ / —.. . �� �5ZR1 R1 / f y/ 1.� R1 R1 5 R1 .IN 1` S D l�D 5 I R1 R1 _39� n I ` _ IC7s►S��I IIW /,r 7., Til % Ar / LI LTJ „ JO 3 Z Z2. NL Z Z �Z iI— 1 �i �JJ_s / ��i/i/_��' b C -.3� g / % .i i i 7-'7/.',/ it /�. iL40_'__� /VA, 1 :�J ��� / ' _ _ �I ' '/ CD .. !� — rAE„•A a_A_ e ) •A f '�4E" I WE" i .Sk /'j �/r44/ / it 1 ���A -% %�, fif e."._, izz iiiii 11 l'7 ,,, 4./ `/ //% f 7 'RI"' Aar / , , A A ,,,, zo R1 R1 NM 1R1 ' --- R1 R1 (/ ifi / 7L 1 �� 1 // ///--. �I// / E L E GT. N L a I I 7. H �i r 7721ipper �, z 4 v 4 fi I N L 6 - / ■ ` �� v n 1( }1 i$ / '- EQUIP. �► 4/ *�. ,�w / � / /Zip r -. +►. +:,aa ' -y, ? , A_ 1 -A r t / sAE"4 virorr , r.4407-A mum—WAMPANIMI m._.:_a .0.1.k.70 I E El A_____.44_4_44_4 / , IE-L1)(2)Ri,':. ZA A r 7 I 0 .Y.cti> IR1 R1 '.<1i)r-- ii-A00044 P.' / a / RI WRI TIA . ) br C)6F. . i —' ,53 . / On Orr2 , r;A ,R1 1 1 ' / AVIV% L3.__ .. PA I .1/ d' ; Pr I - DA h nv 1 . Y _ia- Y Y ,/. , r____&_y v ____-- . �0 NE�5 n ��/��� / Imo'\�I as �1�1N z� Em �Q I G2I �� .. �/ /_ 7 yr 40 4 X el V V R1" a � � R1 t I .� I I ��� / ` aa� R1 R1 ;,::: /1-'- 1 I/ JAN. E 1 -S2„A 1 8 ,4� r/ / ���i r X„ a as �$ $ y, i /R1 R1 R1 y3 n ®n R1 R1 R1 , I R1 R1 R3'' R3” '� / - 3 NL wr -o Ill /bra . / / n�'. _ , - 4 _ V/ 1� v v �Vx e x x x �v �v 1 �� / �JJ I�. /;' .� N $6 3 R3 / /. /,X„ 3 �e1CI QI E1� �1=1 .E 3x3 aa3 \�1 I _ / P 03 5;,'8 R1 R f „X„ 1 as 2 R1 R1 - R1 q 4 j ii3 R1 RI R1 (E) (E) (E) (E) R1 as _a_aa E ® fs NL n as _a—aa r I ////z/Z/ : . .. ;,//:- � •Cnx\\ x x x Q , .• -9-x x3, n x _ .- e x u NL - O 6 $- �...� I a /i /""„/ / i.W v® ,R3„ 1 R3.. ® 7 cp.�u R1 "R1 R1 � R1 R1 x R1 1 R1 E) (E) iE) x cE) (E) (E) R1 R1 w w "o 1 - .4 A .�� x� H. w cs3A t A t 'p t '4 t `�,�. / % %/A,. A A 71:/AerAlir . ice,/ ��.�..„ e X �Q x n X n X _ n -X n X x n X �_X n X X e X S ll _E - } r31 j r /ter r� 'LII-"'4--,/ylI/�� / ` V i Eddy /. .. ....v1i., 'R3' "R3” AE'' i R1 R1 R1 A i i Cr „R 1 1 (E) (E) �� /// R1 R1 R1 CDa (E) (E) (E) (E) R1 R1 a o , I�_ r r �_r W / 7/7/4 ./t/�. / rr�� w w A 6 b A A 44aiiSIAPVA __. I g V1 t .A t j t i t B AIG - ' , ix `� x x e x . x �,_,x x- n x ID X 0 . NL x x �/�. / oc:}2 _ ���y,, ins AAM irir Ila 7 x x —. -- / IN NG ROC”' 2 %rP c1I , ■ CL ' Z A,/ ,/ � = z ® 7 523 R1 .( R1 R1 I R1 R1 R1 RI • q :A A oA r r r �: ��, �� a / ,I b t — t �t — t „$ /„ E 11 ,,Ii., . ''B"0 Aidr A li 1 J a a x x .l "A ir 0-4-rir, ,V/ / „ Ati s• fifkr „R1B7Arr �_ / �� a A07 __I 0 �. . .� % -- ii . � z,/,/ ��// AE1 �� ����1� '�'�/ s/. iii / j ,i�� F CC I (E) 1.- 0 z), t fr /A!" . R1 /, er /, L - : DATE— a�ri�rrrrAPi■r t r• (-/i,e / ; - ! �A U I,A 6 \ A u p A u In- - 05/23/2018 �,� A_i SCALE AS NOTED i _!`a! 1 -~ MGR co ® o o © + _, , �— o U U JOB JRA CEN014 SHEET PARTIAL FIFTH FLOOR CEILING PLAN - LIGHTING N SCALE: 1/8” r- 1 -0E -401 OF SHEETS 1 HDL DESIGN HEREBY EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE Pt ANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERM IISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I M REVISIONS BY Z O 2E v ~ ';4-' 0% o n Q ua � SECURITY CONTACT: c1 m Np uU O ¢ � Z r PAUL JENSEN Z - m u; 1? CENTENE SECURITY SYSTEMS SPECIALIST O ICAj 2 w MOBILE: 916-206-3080 U , Z 3 U . V • ., w Z i 24 Lw � Z � I g :z< w # PLAN NOTES - FIRE ALARM BY E.C. K PLAN NOTES - SECURITY SYSTEMS Z t ILIC ' 1. PROVIDE NEW OR RELOCATED FIRE ALARM SYSTEM SIGNAL. CONNECT 1. PROVIDE DOOR TYPE 60 SECURITY SYSTEM ROUGH-IN. REFER TO z g U 0 a p w ¢ � � � Q � � TO EXISTING BUILDING FIRE ALARM SYSTEM. SECURITY SYSTEM ROUGH-IN DETAIL 11E-102. Z 7 - O - a r- 'o 1 L- 2. PROVIDE NEW OR RELOCATED FIRE ALARM SYSTEM CEILING SMOKE 2. PROVIDE DOOR TYPE 70 SECURITY SYSTEM ROUGH-IN. REFER TO U w 06 o 2 DETECTOR. CONNECT TO EXISTING BUILDING FIRE ALARM SYSTEM. SECURITY SYSTEM ROUGH-IN DETAIL 1/E-102. Vm �o -C3. EXISTING DOOR ACCESS CONTROL PANEL INTERLOCKED WITH FIREU �%°% oALARM SYSTEM. NEW 5TH FLOOR CONTROLLED DOOR HARDWARE WILL cs CONNECT TO THIS PANEL. v Q0<446,7,!: o4. PROVIDE"NORMALLY CLOSED" FIRE ALARM CONTROL RELAY MODULE �FOR RELEASING OF DOOR ACCESS SYSTEM UPON ACTIVATION OF THE U ,- tFIRE ALARM SYSTEM. COORDINATE REQUIREMENTS WITH DOOR �p PROFeACCESS SYSTEM VENDER. INSTALL RELAY ON PLYWOOD ABOVE DOOR ‘11,71::"� G)N � sS/80-2:1: �'LACCESS PANEL, +60" A.F.F. INSTALLATION MUST BE COMPLETE PRIOR R TO FURNITURE INSTALLATION. 7 53 FE 9 ,r GENERAL NOTES " �'" 47:1::c.'5.49:1;• g 20 A. CUT AND PATCH WALLS AS REQUIRED TO INSTALL NEW FLUSH BOXES AND CONDUIT IN EXISTING WALLS. 2Q19 W o ,C 0 lighli ag Zo O Wt m n n Q �� 0 _i � -- ,_r_� � n n n Z 1 § O _ _ 'M Y j . % ;i7//ii- -/:,V,/,/,'/-__ ' m it,;;ilii)• : 'i/ii/i/ $/ iii' •Iii, •/ i/ii� / / ,,/,ii/ i�/i"' it AI: m 0 , Cr / ,, =OFFICE 14 8*. L,-- .. 532 /7/ OPEN OFFICE 4 IEy ����S ' • 533 Os HOTEL COLLABORATION � - f ' 2 2❑ I ` I CONF. 2 1 ', OF O CONF. I 5�3� El ,,,, Os s s 5ml cE) OFFICE 13 ® ❑ s j j.1. 531 . ..—.� 1 , , N DDLE 1 1 MUDDLE 2 FEN/� a� F �® -536 2 F 2 1 / ii� A „., , 1,,,/ , , , e, , , , , A:. E=1.4 Q ❑ 1211=1 ® 1 ;/ �, F �- .IIS .=d. ' //4". / / Ayy ,, ' / ����1 / ��r ��V„,wrir /r�I� 10,"�� I 114, ❑ ._ i� %, iii �ii����ii a�.J ��: . o. / ....„ U rg. ® Uf-h-ICa E1 I 4__3_)e 1 / /��,!�/�_� P r= / F��i / % I „+ ;� c„3 / 530 2❑c no Oa-�.' ❑ j t / ���.• �__ / f I iir. L. N S S NUDDL 3 � %/. / `S , /,...1,,r� ' , , I Asa o r i —,, 2 53-11 E PHONE �!!f! ► / __4 ;,% / ; // % / q o� / Os . , ! I IL, :ETWOIRKmi,....._...„.0.14 ,,, but Ee g 504,4 /' ' • r / , 1!/;1:_,, // �/ ,/ :'/ 42)E3 , ' t/./14- / ',////// /, CC r—ter—� ',,,,,'///// 'Y 'i �/ , ,, r� r ' I�///� /' 2 F ' j � �/ /- ELECT, I II I // A. l // �/ I /r ' Z t 1 REc �G � , 41/ S / ' / / QUIP. II II / i1•. • .t� (E) ; 11,00„ / .� ri , • ill�PRiNT _- z ,1-//// . I ; {E)CE a I--1r--1 / -,sfa I , : / , . - , %� Q 534 /� F O / , , ,/� __ / ; . / , ; -llik ;/ , j�% %� r��, 0 3 fp/ ./ /4 ., / O STOP. , , I I // , 41/ ,1�%fIIII �� I%�I,.0/ Ii s s38 / / / © cMi / / / ' /� %// /// rxi ,, ...4 , �x =I kfi NON-RATED CORRIDOR 1 OS sv�(F) 4.�' --POTHER'S 7-4eds /� AMULTI-PUI�OSE (E)Box / • ROOM n Q% „,:,,4 ,/, / %! ;�/ z CIS IE) ROOM i la, 1 El A: // / / JAN. 5z2a / /(// , , /%':4/:,. i.ZPP./.4% / , ,:, ,, /: I B 7 ii-_ •41.0 sl I 1 / ,/ //// / / ❑o OPEN OFFICE 3 E / . ///. . . . . . . .,/�. . . ,. i / / N $ 528 +, J. �'� ❑ S r-, l .E J .//, i O541 111 r 1 2 F 23 {E) A3 El ❑05 4 ®n 0 g Do c S7 . z IE) ❑ [] (E) �► a. 0 O STORAGE F ► �✓►;' N� W FF s (E) 541 OS ✓./:,:i Os Q0 S BREAK _ /, 1 �I � T THIN ' � ' , i � - IYI❑ �i ❑ RA G ROOM � i j II Z 11 �, , I Q . r ,_, . -. - 523 OFFICE 11 ~�I 1 •/�i%� _ I /#I� Sri 1 / jr 4I, I”I! %i�iU�1%L., I:: ' . S .^ • 529 cm H L CC '� firm,. „; /ti—Al ' po AlIt 17 . !pi, , a) Z,'' - ' rj/A"1- OIII i -/ i //iii%� i/i%iCl /.�!� /f/,/ M '; i �i%i�.�/.,.�� r///�/iii%�i; r �� � 'I �� i%/iiia / -////' '/%/-/A1,i �i fill /� iiia ii///L/,i iii i /�/ilii � //, /// , —I < / P W 1 1 / 'I" OS I 15!3 AA REF )4 10 TE1/////. iii . _fl 8 -v/ y -- SCALE � AS NOTED u5_�l� I,t—' 6 7 8 MGR 010 020 030 0 0 �1 o 0 0 0 JRA JOB CEN014 SHEET PARTIAL FIFTH FLOOR PLAN - FIRE ALARM AND SECURITY SYSTEMS E-501 OF SHEETS IHDL DESIGN HEREB1EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY R#GHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIISION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. ! I I I REVISIONS BY INSULATION MATERIALS SCHEDULE FIRE PROTECTION CRITERIA PLUMBING CRITERIA PLUMBING CRITERIA CONT. PLUMBING ABBREVIATIONS z = Qo co �Q I Ce' �'� 1. DELEGATED DESIGN: DESIGN SPRINKLER SYSTEM, INCLUDING COMPREHENSIVE 1. BEFORE SUBMITTING A PROPOSAL, THE PLUMBING CONTRACTOR SHALL VISIT THE SITE FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE AND SHALL REPAIR OR AD AREA DRAIN H 0 c) 0 !. S c�P� ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING OF WORK AND FAMILIARIZE HIMSELF WITH ALL SITE CONDITIONS. PLUMBING REPLACE WITHOUT COST TO THE OWNER OR TENANT ANY EQUIPMENT WHICH IS Q w a U to �� °� CONTRACTOR SHALL CAREFULLY EXAMINE ALL CONSTRUCTION DOCUMENTS. DEFECTIVE.OR IMPROPERLY INSTALLED. IN ADDITION THIS CONTRACTOR SHALL AHJ AUTHORITY HAVING JURISDICTION r� a' ^ C7 r, 5 9. PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED. p4 �� SUBMISSION OF A BID WILL ACKNOWLEDGE THE PLUMBING CONTRACTOR HAS VISITED ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS qp ACCESS PANEL 0 Z O Z a yQ4 Q�Q 2. BEFORE SUBMITTING A PROPOSAL, THIS CONTRACTOR SHALL VISIT THE SITE OF WORK THE SITE AND EXAMINED ALL CONSTRUCTION DOCUMENTS AND BID INSTRUCTIONS.ALL OR OTHER EQUIPMENT CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF 2 --i m tt {� •4 Q' PLUMBING WORK IN THE CONSTRUCTION DOCUMENTS,AND REQUIRED BY OTHER EQUIPMENT OR MATERIALS INSTALLED IN THIS PROJECT. ARVTR ACID RESISTANT VENT THRU ROOF 0 vHi Z �' AND FAMILIARIZE HIMSELF WITH SITE CONDITIONS THIS CONTRACTOR SHALL �P CAREFULLY EXAMINE ALL CONSTRUCTION DOCUMENTS. SUBMISSION OF A BID WILL DIVISIONS, GENERALLY INSTALLED BY THE PLUMBING CONTRACTOR, WHERE ARV ACID RESISTANT VENT (� 5' z U u] 5• G ACKNOWLEDGE THIS CONTRACTOR HAS EXAMINED ALL CONSTRUCTION DOCUMENTS EQUIPMENT IS PROVIDED BY OTHERS. SHALL BE INCLUDED. IT IS EXPRESSLY 13. FURNISH AND INSTALL STANDARD WEIGHT CAST IRON SOIL PIPE MANUFACTURED PER `� U .J TYPE OF MATERIAL NOTES Qp AND THE PROJECT MANUAL, ALL ITEMS ON THE CONSTRUCTION DOCUMENTS AND UNDERSTOOD THAT THIS PROPOSAL IS BASED ON THE ABOVE REQUIREMENTS AND "CISPI STANDARDS"AND BEARING THIS TRADEMARK PROVIDE STANDARD NO-HUB ARW ACID RESISTANT WASTE - • r O J INCLUDED IN ALL OTHER DIVISIONS OF THE PROJECT MANUAL, NORMALLY INSTALLED THAT IT COVERS EVERYTHING NECESSARY TO COMPLETE THE SCOPE OF WORK FITTINGS FOR ALL CAST IRON DVM/PIPING SYSTEMS. SCHEDULE 40 PVC DWV SYSTEM Z w 0 ❑ LL BY THIS CONTRACTOR,AND PROVIDED BY OTHERS SHALL BE INCLUDED. IT IS DESCRIBED_ MAY BE INSTALLED WHERE ACCEPTABLE TO THE LOCAL AHJ. PVC PIPE AND DM CB CATCH BASIN cid w w Z 0 1/2 INCH THICK ELASTOMERIC CLOSED CELL INSULATION-ASTM E-84 OPTIONAL CW FITTINGS SHALL BE SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURESZ COVERING ® EXPRESSLY UNDERSTOOD THAT THIS PROPOSAL IS BASED ON THE ABOVE CI CAST IRON REQUIREMENTS AND THAT IT COVERS EVERYTHING NECESSARY TO COMPLETE THE 2, PLUMBING CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ITEM(S)OF THE INSTALLATION INSTRUCTIONS. INSTALL DVW SYSTEM WITHIN TEMPERATURE Z d SCOPE OF WORK DESCRIBED. CONTRACT DOCUMENTS THAT ARE NOT UNDERSTOOD OR WHERE CONFLICTS MAY CONDITIONS AS SPECIFIED BY THE MANUFACTURER. INSTALL CLEANOUT TEE AND CO CLEANOUT e, Z m c N N U EXIST. CLARIFICATIONS MUST BE PRESENTED AS A"REQUEST FOR INFORMATION"(RFI) CHROME ACCESS COVER IN BASE OF EACH VENT STACK. TEST ALL DWV PIPING PER ES U Q 5 IN WRITING PRIOR TO SUBMITTING A BID. RFI SHALL BE PRESENTED A MINIMUM OF FIVE REQUIREMENTS OF THE AHJ OR AS A MINIMUM TO TEN(10)FEET HEAD OF WATER FOR DF DRINKING FOUNTAIN 8 8, V 00 b o• v 3. FIRE PROTECTION CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ITEM(5)OF - c Q ap w PLUMBING MATERIALS SPECIFICATION ?JTHE CONTRACT DOCUMENTS AND PROJECT MANUAL THAT ARE NOT UNDERSTOOD OR (5)WORKING DAYS BEFORE THE BID DATE. OBTAIN THE RFI FORM AT AT LEAST 2 HOURS WITH NO LEAKS BEFORE COVERING.CAST IRON NO-HUB IS DN DOWN w Zso Z " , °° � � Q� WHERE CONFLICTS MAY EXIST. CLARIFICATIONS MUST BE PRESENTED AS A R> QUEST VW .GANDWENGINEERING.COM/DOCUMENTS. SUBMISSION OF A BID WILL REQUIRED ABOVE CEILINGS OR IN CAVITIES USED AS AN AIR PLENUM; NO PVC PIPING Z Z0 V I C a co Q \Q DS DOWNSPOUT cx I I FOR INFORMATION IN WRITING PRIOR TO SUBMITTING A BID.ANY REQUEST FOR ACKNOWLEDGE THE PLUMBING CONTRACTOR UNDERSTANDS THE SCOPE OF WORK. WILL BE ALLOWED IN AN AIR PLENUM. REFER TO ARCHITECTURAL AND MECHANICAL Q �? U A 1 - '; M �, ,_ �Q\ INFORMATION SHALL BE PRESENTED A MINIMUM OF FIVE(5)WORKING DAYS BEFORE MEANS AND METHODS OF INSTALLATION,AND MATERIALS TO BE USED. RFI THAT HAVE CONSTRUCTION DRAWINGS TO DETERMINE WHERE AIR PLENUM LOCATIONS OCCUR IN (E) EXISTING �/ °� �0 n n , V� V THE BID DATE. SUBMISSION OF A BID WILL ACKNOWLEDGE THE FIRE PROTECTION NOT BEEN CLARIFIED PRIOR TO BID,WILL BE PROVIDED BY THE PLUMBING THIS PROJECT PRIOR TO BID. Q Qf 0 J• CONTRACTOR,AS DIRECTED BY THE ENGINEER OF RECORD.AND THE MOST EC ELECTRICAL CONTRACTOR cD iv t ,- \ �� 0 CONTRACTOR UNDERSTANDS THE SCOPE OF WORK, MATERIALS TO BE USED,AND V O � Jk� ,�� J�0 ��J METHODS OF INSTALLATION.ALL CLARIFICATIONS OR REQUESTS FOR INFORMATION STRINGENT MATERIALS, EQUIPMENT.AND SCOPE OF WORK SHALL APPLY. NO 14. WATER PIPING SHALL BE COPPER AS SCHEDULED ON THE DRAWINGS. SHUT-OFF EWC ELECTRIC WATER COOLER U 1 °%°% �� �. . 'R THAT HAVE NOT BEEN CLARIFIED PRIOR TO BID WILL BE PROVIDED FOR BY THE FIRE ADDITIONAL COMPENSATION WILL BE MADE FOR THE FAILURE OF THE CONTRACTOR TO VALVES SHALL BE BRONZE BODY NIBCO C-580 BALL VALVES RATED FOR 125LB. J p) 0 �� �P¢ G,� ,,Q F- PROTECTION/FIRE CONTRACTOR AS DIRECTED BY THE ENGINEER AND THE MOST OBTAIN CLARIFICATIONS PRIOR TO BID. WORKING PRESSURE OR INDUSTRY STANDARD EQUAL. TEST WATER PIPING PER THE FCO FLOOR C.O. �' d " a 3 5P Q4\' ,\0>\ 4- �� STRINGENT MATERIALS AND CONDITIONS OF WORK SHALL APPLY. NO ADDITIONAL AHJ REQUIREMENTS OR AT A MINIMUM TO 125LB. FOR AT LEAST 24 HOURS WITH NO ED FLOOR DRAIN U d 8 O��G 5� <<i� ����' ���� COMPENSATION WILL BE MADE FOR FAILURE OF THE CONTRACTOR TO COMPLY WITH 3. THE EQUIPMENT, MATERIALS,AND MANUFACTURERS SCHEDULED IN THE CONTRACT LEAKS BEFORE COVERING INSULATE COLD, HOT,AND HOT WATER RETURN PIPING AS Q o DOCUMENTS SHALL FORM THE BASIS OF DESIGN. THE PLUMBING CONTRACTOR SHALL SCHEDULED ON THE DRAWINGS. PROVIDE WATER HAMMER ARRESTORS ON THE COLD FL FLOWLINE a ° J�v �O� �y>P b�Q �4r THESE REQUIREMENTS. Z co C' -\ CrBASE HIS BID ON THE SCHEDULED MATERIALS AND EQUIPMENT. ALL OTHER AND HOT WATER SUPPLIES FOR EACH PLUMBING FIXTURE.WATER HAMMER ,e �Q� �5 \�� 4. SHOP DRAWINGS SHALL BE SUBMITTED AT ONE TIME AND ALL ITEMS REQUIRING A EQUIPMENT, MATERIALS,AND MANUFACTURERS,ARE CONSIDERED SUBSTITUTIONS ARRESTORS SHALL BE EQUAL TO"SIOUX CHIEF"HYDRA-RESTER SIZED AND INSTALLED FSC FOOD SERVICE CONTRACTOR TYPE OF MATERIAL �`�� PCO ppb �J� g / SUBMISSION SHALL BE SUBMITTED ELECTRONICALLY(.PDF)WITH ALL ITEMS CLEARLY PROPOSED SUBSTITUTIONS MAY BE SUBMITTED FOR REVIEW AFTER THE ENGINEER IN ACCORDANCE WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS AND SIZING FPC FIRE PROTECTION CONTRACTOR MAY 2 ` 2018 SCHEDULE 40 PVC W/SOLVENT CEMENTED DRAINAGE PATTERN MARKED.THE NAME OF THE PROJECT,ADDRESS OF THE CONTRACTOR, PHONE HAS RECEIVED A SUBSTITUTION REQUEST FORM. OBTAIN THE SUBSTITUTION REQUEST GUIDELINES. ® ® NUMBER AND CONTACT NAME SHALL APPEAR ON A TITLE PAGE PROVIDE A TABLE OF FORM AT WMN.GANDWENGINEERING,COM/DOCUMENTS. THE PLUMBING CONTRACTOR GC GENERAL CONTRACTOR FITTINGS ASTM D-2665 PRQFES CONTENTS AND TABS SEPARATING ITEMS SUBMITTED. NO EXCEPTIONS WILL BE TAKEN. SHALL MAKE NO PRIOR ASSUMPTIONS ON SUBSTITUTIONS NOT APPROVED BY THE 15- PLUMBING CONTRACTOR SHALL VERIFY THE FLOW LINE OF ALL SEWERS AND DRAIN HB HOSE BIBS Q�Fa `��p SHOP DRAWINGS NOT SUBMITTED IN THIS FORMAT WILL BE REJECTED AND WILL NOT ENGINEER.APPROVALS OF SUBSTITUTIONS ARE CONTINGENT UPON ENGINEER'S CONNECTION POINTS PRIOR TO STARTING CONSTRUCTION. PLUMBING CONTRACTOR .`,' �GVNEER Oji COPPER PIPE-SOFT DRAWN TYPE"K"ASTM B88 ® CAUSE REASON FOR PROJECT DELAYS. THE FIRE PROTECTION CONTRACTOR SHALL REVIEW. SHOULD THE ENGINEER APPROVE A SUBSTITUTION REQUEST.THE PLUMBING SHALL PROVIDE A WATER FLOW TEST AT THE CONNECTION POINT TO CONFIRM THE HD HUB DRAIN 9� REVIEW SHOP DRAWING SUBMITTALS FOR COMPLIANCE, CONTENT AND CONTRACTOR WILL BE HELD RESPONSIBLE FOR ENGINEERING COSTS. PHYSICAL SIZE, SEWER OR DRAIN IS ADEQUATE FOR DESIGN FLOW AND OPERATIONAL PRIOR TO IW INDIRECT WASTE7g ,33QE cr COPPER PIPE-HARD DRAWN TYPE"L"ASTM B88 0 COMPLETENESS. PROVIDE A STAMP WITH THE DATE OF REVIEW, SIGNATURE OF THE CAPACITIES.COORDINATION, SUPPLEMENTAL DRAWINGS AND INFORMING OTHER STARTING CONSTRUCTION. REVIEWER, NAME,ADDRESS AND TELEPHONE NUMBER OF THE FIRE PROTECTION TRADE CONTRACTORS RELATED TO THE INSTALLATION AS TO ANY SPECIFIED ITEM LAV LAVATORY 1: -/ WITH CAST ASTM B16.18 OR WROUGHT ASTM B16.22 SOLDERED JOINT = - CONTRACTOR SHALL APPEAR IN THE STAMP OR TITLE PAGE WITH A WET SIGNATURE_ CHANGES. THE PLUMBING CONTRACTOR SHALL BEAR AS PART OF HIS CONTRACT,ANY 15. PLUMBING CONTRACTOR SHALL SAW-CUT AND PATCH ROOF, FLOORS,WALLS,AND THE FIRE PROTECTION CONTRACTOR WILL BE RESPONSIBLE FOR TRANSMISSION OF ADDITIONAL COSTS INCURRED IN HIS WORK OR BY THE OTHER CONTRACTORS AS A CEILINGS WHERE REQUIRED TO INSTALL NEW PIPING SYSTEMS. SURFACES SHALL BE MB MOP BASIN 1-THE SHOP DRAWINGS FROM THE ENGINEERS OFFICE TO APPROPRIATE OTHER RESULT OF SUBSTITUTIONS TO THE BASIS OF DESIGN. PATCHED AND LEFT READY FOR FINAL SCHEDULED FINISH. ROOFING REPAIRS SHALL MC MECHANICAL CONTRACTOR Y 8 STANDARD WEIGHT NO-HUB CAST IRON ASTM-888 ® PARTIES. SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: FIRE PROTECTION SHOP MAINTAIN THE ROOF WARRANTY AND BE PERFORMED BY A QUALIFIED ROOFING �5 WITH HEAVY DUTY TYPE 304 STAINLESS STEEL COUPLINGS DRAWINGS 4. PLUMBING CONTRACTOR SHALL PERFORM WORK IN A SAFE MANOR. COMPLY WITH CONTRACTOR WHICH MAINTAINS THE WARRANTY OF THE ROOF.THIS COST IS TO BE MH MANHOLE 4 APPLICABLE OSHA SAFETY GUIDELINES DURING THE COURSE OF COMPLETING THE PROVIDED IN THE PLUMBING WORK CONTRACTOR'S BID. CONTRACTOR SHALL INCLUDE OFRD OVERFLOW ROOF DRAIN 1JJ 5. ALL ITEMS OF WORK AND MATERIALS SHALL BE SPECIFICALLY INSTALLED PER WRITTEN WORK DESCRIBED ON THESE CONSTRUCTION DOCUMENTS. REMOVAL AND REINSTALLATION OF CEILINGS AS REQUIRED TO COMPLETE SCOPE OF W PA PIPE ANCHOR INSTALLATION INSTRUCTIONS AND METHODS OF INSTALLATION AS PROVIDED BY THE WORK. ® � � Irk MANUFACTURER OF THE EQUIPMENT OR MATERIAL PROVIDER. THIS CONTRACTOR 5. SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY AS PDF FILES. SHOP PC PLUMBING CONTRACTOR Q SHALL UNDERSTAND THE PRODUCT AND METHODS OF INSTALLATION.ALL REQUESTS DRAWINGS SHALL INCLUDE TRANSMITTAL PAGE(S) INDICATING THE NAME OF THE 17. PROVIDE STRUCTURAL STEEL FRAMEWORK, STRUT.CABLES. HARDWARE,AND Q g WASTE, VENT & WATER CONNECTION SCHEDULE FOR ADDITIONAL INFORMATION DURING CONSTRUCTION WHERE THE CONTRACTOR PROJECT,AND THE NAME,ADDRESS.AND PHONE NUMBER OF THE GENERAL AND HANGING RODS WITH BRACES AND ACCESSORIES WHERE REQUIRED TO HOLD PD PUMP DISCHARGE _ PLUMBING CONTRACTORS. GENERAL CONTRACTOR AND PLUMBING CONTRACTOR EQUIPMENT IN FINAL POSITION. PROVIDE STEEL SHAPES AND FRAMES TO SUPPORT Z O FIXTURE WASTE VENT COLD WATER HOT WATER NOTES HAS NOT PREVIOUSLY OBTAINED THIS INFORMATION FOR BIDDING PURPOSES MAY PVC POLYVINYL CHLORIDE PIPE SHALL REVIEW SHOP DRAWING SUBMITTALS FOR COMPLIANCE, CONTENT AND WALL MOUNTED EQUIPMENT WHERE NORMAL WALL STRENGTH MAY BE INADEQUATE. Q WATER CLOSETS(TANK) 4" 2" 112" RESULT IN BACK CHARGES TO THE CONTRACTOR,AS PROVIDED FOR IN THEILI L. CONTRACT DOCUMENTS, FOR THEIR FRIVOLOUS REQUESTS COMPLETENESS AND PROVIDE A STAMP WITH THE DATE OF REVIEW AND SIGNATURE COORDINATE BLOCKING AND FRAMING WITH THE G.C.AND PROVIDE SEISMIC ANCHORS RCP REINFORCED CONCRETE PIPE WATER CLOSETS(FLUSH VALVE) 4" 2" 1-1/4" OF THE REVIEWER. TRANSMITTAL PAGE SHALL HAVE INDEX WITH SPECIFICATION AND SWAY BRACING IN ACCORDANCE WITH 2O140REGON STRUCTURAL SPECIALTY RD ROOF DRAIN LAVATORIES 1-1/4" 1-114" 112" 112" 6. ALL FIRE PROTECTION WORK SHALL BE DONE UNDER THE SUPERVISION OF THE SECTION AND DESCRIPTION OF SUBMITTED ITEMS. NO EXCEPTIONS WILL BE TAKEN. CODE.SUBMIT SHOP DRAWINGS FOR ALL SYSTEM COMPONENTS FOR PROCESSING. Z URINALS 2" 2" 3/4" CONTRACTOR,WHO SHALL PROVIDE A COMPETENT FOREMAN TO LAYOUT ALL WORK. SHOP DRAWINGS NOT SUBMITTED IN THIS FORMAT WILL BE REJECTED AND WILL NOT RIO ROUGH-IN ONLY J ALL WORK SHALL BE PROVIDED WITH DUE REGARD FOR THE SPACE REQUIREMENTS CAUSE REASON FOR PROJECT DELAYS. EQUIPMENT SHALL NOT BE ORDERED UNTIL 18. THE PLUMBING SCOPE OF WORK SHALL BE BID,AND PROVIDED TO COMPLY WITH THE MOP BASINS 3" 2" 1/2" 1/2" ENGINEER OF RECORD HAS PROCESSED APPLICABLE SHOP DRAWINGS A MINIMUM OF 2014 OREGON PLUMBING SPECIALTY CODE. IT IS UNDERSTOOD THAT THE RPBP REDUCED PRESSURE BACKFLOW PREVENTERILI SINKS 2" 2" 112" 112" OF THE OTHER CONTRACTORS. THE CONTRACTOR SHALL REPORT ANY CONFLICTS OR V DIFFICULTIES IN REGARD TO THE INSTALLATION IMMEDIATELY TO THE CONSTRUCTION SEVEN WORKING DAYS WILL BE ALLOWED FOR SUBMITTAL PROCESSING BY THE CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ITEM IN CONFLICT WITH THE S SOIL NOTES: MANAGER, WHERE CROWDED LOCATIONS EXIST OR WHERE THERE IS A POSSIBILITY OF ENGINEER. SUBMITTALS SHALL INCLUDE BUT NOT LIMITED TO: PLUMBING FIXTURES ADOPTED PLUMBING CODE PRIOR TO BID. FURTHERMORE. BY SUBMISSION OF A BID, CONFLICT BETWEEN TRADES,THE CONTRACTOR SHALL MAKE COMPOSITE AND ACCESSORIES. AND INSTANTANEOUS WATER HEATERS THE CONTRACTOR ACKNOWLEDGES HE HAS PROVIDED ALL EQUIPMENT. MATERIAL AND SD SHOWER DRAIN SUPPLEMENTARY DRAWINGS SHOWING THE EXACT LOCATIONS OF PIPES. CONDUIT, LABOR TO COMPLETELY COMPLY WITH THE ADOPTED PLUMBING CODE, OTHER STATE SDS SECONDARY DOWNSPOUT m. DUCTS AND EQUIPMENT. DRAWINGS SHALL BE BASED ON FIELD MEASUREMENTS AND, 6. SUBMIT AND PAY FOR ALL REQUIRED WORK PERMITS. PROVIDE ALL REQUIRED AND FEDERAL ACCESSIBILITY LAW AND LOCAL ORDINANCES. AFTER CONSULTATION AND AGREEMENT BETWEEN THE TRADES, SHALL BE ADMITTED INSPECTIONS AND RE-INSPECTIONS. PROVIDE A SIGNED CERTIFICATE OF INSPECTION SH SHOWER VALVE BY THE CONSTRUCTION MANGER BEFORE INSTALLATION OF THE WORK. AT THE PROJECT COMPLETION. 19. THE LANDLORDS CONSTRUCTION CRITERIA, LEASE AGREEMENT,AND CONSTRUCTION STANDARDS ARE HERE-IN MADE PART OF THIS CONTRACT.ALL REQUIREMENTS IN THE SS SERVICE SINK 7. FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL 7. PLUMBING CONTRACTOR SHALL UTILIZE DIMENSIONED ARCHITECTURAL DRAWINGS LANDLORDS CONSTRUCTION CRITERIA, LEASE AGREEMENT,AND CONSTRUCTION SW STREET WASHER EXISTING CEILINGS AND WALLS REQUIRED TO INSTALL NEW EQUIPMENT AND AND ELEVATIONS FOR THE LAYOUT OF PLUMBING FIXTURES. REVIEW ARCHITECTURAL STANDARDS REFERRED TO AS TENANT WORK IS DEFINED AS DIVISION 15 PLUMBING MATERIALS. PATCH EXISTING FLOORS, CEILINGS AND WALLS TO MATCH EXISTING LAYOUT AND ELEVATIONS PRIOR TO STARTING CONSTRUCTION.ANY DISCREPANCIES WORK AND IS TO BE PROVIDED BY THE PLUMBING CONTRACTOR. IT IS THE TMV THERMOSTATIC MIXING VALVE SHALL BE SUBMITTED TO THE ARCHITECT FOR CLARIFICATION THROUGH AN RFI PRIOR RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO OBTAIN COPIES OF THESE FINISHES,ALL WORK SHALL BE AREASFROCOMPLETED TO THE CORE-DRILLING G OPEION OF THE ARCHITECT TO STARTING THE WORK. DOCUMENTS AND COMPLETELY FAMILIARIZE HIMSELF WITH THESE DOCUMENTS PRIOR TPRV TEMPERATURE AND PRESSURE RELIEF VALVE AND OWNER. PROTECT ALL FROM THE CDRILLIOPERATION TO BIDDING THIS PROJECT. SUBMISSION OF A BID ACKNOWLEDGES THE WORK UR URINAL 8. THE EXISTING SYSTEM SHALL BE MODIFIED FOR THE NEW FLOOR AND CEILING LAYOUT 8. ALL EQUIPMENT AND MATERIALS SHALL BE SPECIFICALLY PROVIDED PER WRITTEN CONTRACTOR HAS COMPLIED WITH THIS REQUIREMENT OF THE CONTRACT. V VENT INDICATED ON THE ARCHITECTURAL DRAWINGS.THIS CONTRACTOR SHALL PROVIDE INSTALLATION INSTRUCTIONS AS PUBLISHED BY THE MANUFACTURER OF THE ALL ENGINEERING AND CONSTRUCTION GENERALLY DESCRIBED AS"DESIGN/BUILD". EQUIPMENT OR MATERIAL PROVIDER. MEANS AND METHODS OF INSTALLATION ARE TO 20. THE PLUMBING CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING FIXTURES, VTR VENT THRU ROOF THIS INCLUDES BUT IS NOT LIMITED TO, REVISING ALL PIPING AND HEADS, HYDRAULIC BE PROVIDED BY THE PLUMBING CONTRACTOR. PLUMBING CONTRACTOR SHALL PIPING, EQUIPMENT, RELATED ITEMS OCCURRING IN DEMOLISHED WALLS, FLOORS. CALCULATIONS.CONSTRUCTION DRAWINGS, EQUIPMENT CUT SHEETS,AND PERMITS. UNDERSTAND THE PRODUCT, MEANS AND METHODS OF INSTALLATION. THE PLUMBING ATTICS,CEILING CAVITIES AND THE ROOF. REFER TO THE ARCHITECTURAL DRAWINGS UV WASTE CONTRACTOR SHALL OBTAIN THE INSTALLATION INSTRUCTIONS AND REQUIREMENTS FOR THE GENERAL SCOPE OF DEMOLITION. PLUMBING FIXTURES AND RELATED ITEMS ALL WORK AND ENGINEERING SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 13. WC WATER CLOSET ALL CONSTRUCTION DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE PRIOR TO BID. ALL RFI AND CLARIFICATIONS OF SCOPE DURING CONSTRUCTION WHERE NOT TO BE RETAINED BY THE OWNER OR TENANT MUST BE REMOVED FROM THE LOCAL FIRE INSPECTION AUTHORITY PRIOR TO STARTING ANY WORK. PROVIDE THE CONTRACTOR HAS NOT PREVIOUSLY OBTAINED THIS INFORMATION FOR BIDDING PREMISES,TO BE LEGALLY DISPOSED OF BY THE PLUMBING CONTRACTOR.ALL LOOSE WCO WALL CLEANOUT QQ ENGINEER SEALED SUBMITTALS WHERE REQUIRED BY THE AUTHORITY HAVING PURPOSES WILL NOT BE CAUSE FOR ADDITIONAL COSTS OR CONSTRUCTION DELAY. ENDS OF SYSTEMS WHERE SUCH ABANDONMENT HAS TERMINATED SHALL BE TRIMMED WH WALL HYDRANT O JURISDICTION. ALL WORK AND DESIGN SHALL BE PERFORMED UNDER THE DIRECTION CLEAR AND APPROPRIATELY CAPPED OR SEALED IN A SAFE AND SECURE MANNER ��L77 OF A REGISTERED OREGON PROFESSIONAL ENGINEER. ENGINEER OF RECORD SHALL 9. MIE PLUMBING UN ARE DIAGRAMMATIC CONTRACTOR SHALL ITAND GIVEER PROVIDE IC COORDINATION WI WITH OTHER TRADES; ANDREQUIRED.DES; BEHIND NEW FINISHES. MAINTAIN PLUMBING SYSTEM CONTINUITY TO ADJOINING AREAS PPLUMBING SYMBOL LIST CARRY ERRORS AND OMISSION COVERAGE IN AN AMOUNT OF$1,000.000.00. LOCATIONS ONLY. PLUMBING CONTRACTOR SHALL COMPLETELY REVIEW ® 05 9. ALL PIPING SHALL BE PROVIDED AND INSTALLED TO MEET REQUIREMENTS OF NEPA 13. ARCHITECTURAL DRAWINGS, STRUCTURAL DRAWINGS,AND SYSTEMS DRAWINGS OF 21. THIS CONTRACTOR SHALL CONFINE HIS ACTIVITIES TO THE AREA SET ASIDE FOR HIM 0 BALANCING VALVE(BAL.V.) LI/�, CI OTHER TRADES FOR DETAILS OF CONSTRUCTION. ROUGH-IN OF PLUMBING FIXTURES, TO DO HIS WORK AND SHALL NOT INTERFERE WITH ANY OF THE OWNER OR TENANT N ALL PIPING SHALL BE SIESMICALLY RESTRAINED IN ACCORDANCE WITH NFPA 13 AND THE ADOPTED BUILDING CODE. EQUIPMENT. PIPING,ATTACHMENTS.AND HANGERS SHALL BE BASED ON THIS REVIEW. ACTIVITIES. THIS CONTRACTOR WILL NOT BE PERMITTED TO STORE MATERIAL EXCEPT AUTOMATIC SPRINKLER SYSTEM Z Q EXACT LOCATIONS AND FINAL LAYOUT SHALL BE DETERMINED IN THE FIELD, PROVIDE WITHIN THE AREAS AS DIRECTED BY THE G.C. SHOULD ANY DISTURBANCE OF EXISTING aj 10. PROVIDE FIRE STOP AT EACH RATED WALL, FLOOR, OR CEILING ASSEMBLY ALL NECESSARY EQUIPMENT, FITTINGS, HANGERS. SUPPORTS.AND OFFSETS INSTALLATION BE NECESSARY, THE CONTRACTOR SHALL SO INFORM THE OWNER OR PENETRATION FIRE STOP SYSTEMS SHALL BE EQUAL TO"3M".APPLY IN STRICT 1111 L- REQUIRED FOR A COMPLETE INSTALLATION IN ALL RESPECTS.THE PLUMBING TENANT WELL IN ADVANCE OF THE TIME CONTEMPLATED FOR THE DISTURBANCE. >1 GATE VALVE(GT.V.) 0 Ee CONTRACTOR MEANS AND METHODS OF INSTALLATION SHALL PROVIDE FOR AFTER A PLAN ACCEPTABLE TO THE OWNER OR TENANT HAS BEEN FORMULATED, THE COMPLIANCE WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. PROVIDE SHOP DRAWINGS FOR REVIEW WITH THE U.L. LABEL AND TEST CRITERIA. OPERATING EFFICIENCY, NEATNESS OF APPEARANCE.AND EASE OF MAINTENANCE. G.C. SHALL KEEP IN CLOSE PERSONAL CONTACT WITH THE WORK TO SEE THAT IT IS DTIGLOBE VALVE(GL.V.) Z REVIEW SEPARATION WALLS, CEILINGS AND FLOOR ASSEMBLIES ON THE THE PLUMBING CONTRACTOR WILL PREPARE DIMENSIONED FIELD ERECTION EXECUTED IN ACCORDANCE WITH THE AGREED PROCEDURE. ARCHITECTURAL DRAWINGS PRIOR TO BIDDING THE PROJECT. PROVIDE FIRE DRAWINGS WHERE REQUIRED FOR USE BY THE INSTALLERS,TO INSURE PROPER N CHECK VALVE(C.V.) STOPPING WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. EQUAL INSTALLATION AND COORDINATION. THE PLUMBING CONTRACTOR SHALL TAKE THEIR 22. CONTINUITY OF ALL BUILDING SERVICES AND UTILITIES SERVING FACILITIES IN THE W Q F OWN MEASUREMENTS AT THE BUILDING,AND BE RESPONSIBLE FOR THE CORRECT BUILDING SHALL BE MAINTAINED WITHOUT INTERRUPTION, EXCEPT FOR SUCH A PERIOD SYSTEMS AS MANUFACTURED BY"SPEC SEAL"OR"HILTI"WILL BE ACCEPTABLE. LAYOUT, INTERPRETATION,AND USE OF ALL SIZES AND DIMENSIONS.THE OF TIME DESIGNATED BY THE G.C. THE CONTRACTOR SHALL SO ARRANGE AND ❑� GAS SHUT-OFF VALVE(S.O.V.) (1) 11. ALL SPRINKLER HEADS SHALL BE INSTALLED PER NFPA 13 FOR USE AND APPLICATION. CONTRACTOR SHALL KEEP"AS-BUILT"INFORMATION DURING CONSTRUCTION AND EXECUTE HIS WORK THAT ANY CONNECTIONS, EITHER TEMPORARY OR PERMANENT. IN UNFINISHED AREAS WITH NO CEILINGS, UPRIGHT SPRINKLER HEADS SHALL BE FURNISH TO THE OWNER OR TENANT A RECORD SET OF LEGIBLE BLACK LINE PRINTS OR REARRANGEMENT OF PRESENT EQUIPMENT AND PIPING SHALL BE IN SUCH A PRESSURE REDUCING VALVE(P.R.V.) BRASS UPRIGHT TYPE. SPRINKLER HEADS IN FINISHED AREAS SHALL MATCH EXISTING AND AN ELECTRONIC COPY OF THESE DOCUMENTS AT THE PROJECT COMPLETION. MANNER AS TO ASSURE FULL RESUMPTION OF SERVICE AT THE TIME DESIGNATED BY THE G.C. PROVIDE TEMPORARY CROSS CONNECTIONS. PIPING. HANGERS AND VALVES SPRINKLER HEADS OR MATCH BUILDING STANDARD SPRINKLER HEADS IN C} BALL VALVE(B.V.) APPEARANCE AND FUNCTION, COORDINATE WITH BUILDING OWNER OR PROPERTY 10. REVIEW ARCHITECTURAL DRAWINGS AND EXISTING SITE CONDITIONS FOR ALL FIRE NECESSARY TO ASSURE THIS CONTINUITY OF THE BUILDING PLUMBING SYSTEM AT NO t I MANAGER. INSTALL SPRINKLERS IN SUSPENDED CEILINGS IN CENTER OF ACOUSTICAL RATINGS AND FIRE RATED ASSEMBLIES PRIOR TO BIDDING THE PROJECT. PROVIDE FIRE ADDITIONAL COST TO THE OWNER OR TENANT, MAINTAIN IS DEFINED TO INCLUDE, BUT STOP AT EACH RATED WALL, FLOOR, CEILING-ROOF ASSEMBLY PENETRATION. FIRE IS NOT LIMITED TO, REMOVAL, MODIFICATION AND REINSTALLATION OF EQUIPMENT AND VSTRAINER(STIR.) CEILING PANELS OR CENTERED IN HALF OF 2'x4'TEGULAR CEILING PANEL STOP SYSTEMS SHALL BE MANUFACTURED BY"3M". PROVIDE IN STRICT COMPLIANCE PIPING AS NEEDED TO SUSTAIN THE EXISTING WORKING CONDITION OF THE PLUMBING WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. PROVIDE SYSTEM. THE PLUMBING CONTRACTOR SHALL RETURN THESE SYSTEMS OR AREAS TO 12. ALL HANGERS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH NFPA 13 O FURNISHED BY OTHERS r STANDARDS.ALL PIPING SHALL BE TESTED IN STRICT ACCORDANCE WITH NFPA 13 INSTALLER CERTIFICATION SIGNS AT EACH PENETRATION. PROVIDE SHOP DRAWINGS FULL WORKING ORDER AT PROJECT COMPLETION. [�1 .... FOR REVIEW WITH THE U.L LISTING AND TEST CRITERIA. PROVIDE FIRE STOPPING REFER TO SPECIFICATIONS FOR ALL SEISMIC RESTRAINT REQUIREMENTS APPLICABLE N WHERE REQUIRED BY THE AHJ. EQUAL SYSTEMS AS MANUFACTURED BY"SPEC SEAL" 23. PLUMBING FIXTURES THAT REMAIN SHALL BE PROTECTED FROM DUST AND DAMAGE ® PIPING BELOW FLOOR OR GRADE TO THIS WORK. PROVIDE A INSPECTORS TEST CONNECTION WHERE REQUIRED BY THE OR"HILTI"WILL BE ACCEPTABLE. DURING CONSTRUCTION LOCAL INSPECTION AUTHORITY. . © PIPING ABOVE CEILING 13. THE EXISTING AREAS TO BE REMODELED ARE CURRENTLY PROTECTED WITH A WET 11 PROVIDE PIPING. AND HANGER PENETRATIONS OF NON-RATED ASSEMBLIES WITH PIPE SPRINKLER SYSTEM. DRAFT STOPPING, OR SMOKE BARRIER SEALANT SYSTEMS. THROUGH PENETRATION XX © O PLAN NOTE SYMBOL SEALANT SYSTEMS SHALL BE MANUFACTURED BY"3M".APPLY IN STRICT COMPLIANCE WITH THE MANUFACTURER'S APPLICATION DETAILS AND INSTRUCTIONS. PROVIDE Q DRAFT STOPPING OR SMOKE BARRIER SEALANTS TO MEET APPROVAL OF THE AHJ. REVISION SYMBOL EQUAL SYSTEMS AS MANUFACTURED BY"SPEC SEAL"OR"HILTI"WILL BE ACCEPTABLE. 12. PLUMBING CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT AND MATERIAL O SANITARY STACK NUMBER INSTALLED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS AND WORKMANSHIP X DOWNSPOUT LETTER PLUMBING FIXTURE SCHEDULE CONNECTION TO EXIST.VENT LINE. GENERAL NOTES - PLUMBING VERIFY SEZE AND LOCATION IN THE FIELD. I-- NEW CONNECTION TO EX.WASTE OR SAN.SEWER. LU PLUMBING FIXTURES FIXTURE SCHEDULE A. CONTRACTOR SHALL CAREFULLY COORDINATE ANY FLOOR PENETRATIONS WITH ® VERIFY LOCATION,SIZE,AND FLIN THE FIELD, W GENERAL CONTRACTOR,TENANTS CONSTRUCTION COORDINATOR, BUILDING OWNERS ALL FIXTURES INCLUDED IN THIS PROJECT SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR UNLESS OTHERWISE SINK-STAINLESS STEEL-SINGLE COMPARTMENT-UNDERMOUNT-ADA-INSTANTANEOUS HEATER-(S-1) REPRESENTATIVE AND TENANT BELOW. POST TENSIONED FLOOR SLAB CONSTRUCTION NEW CONNECTION TO EXIST.WATER LINE. SHALL BE X-RAYED AND ALL STRUCTURAL SYSTEMS PERMANENTLEY MARKED ON THE VERIFY SIZE AND LOCATION IN THE FIELD. Cl)I NOTED. PROVIDE ALL NECESSARY HANGERS, BOLTS,ANCHORS, STEEL ANGLE,AND BRACKETS. ALL FIXTURES SHALL BE VJ PROPERLY CONNECTED TO DWV SYSTEM AND WATER LINES AND SHALL BE INSTALLED IN AN ABSOLUTELY RIGID AND ELKAY#ELUHAD281645, 30-1/2"X 18-1/2"SINGLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK 4-1/2"DEEP, UNDERMOUNT. FLOOR STRUCTURE AND IDENTIFIED PRIOR TO ANY PENETRATION BEING PERFORMED. PLUMBING PIPING W SUBSTANTIAL MANNER,WITHOUT DAMAGE TO ANY ADJOINING WORK OR FINISH. PROVIDE SPECIFICATION GRADE SEALANT AMERICAN STANDARD FAUCET#4332.350.F15, PEKOE SEMI-PROFESSIONAL KITCHEN FAUCET WITH 1.5 GPM FLOW. SINGLE AT ALL WALL AND FLOOR CONNECTIONS COMPATIBLE WITH THE COLOR OF THE PLUMBING FIXTURE AND FINISH. HOLE MOUNTING AND STAINLESS STEEL(PVD)FINISH. 1-1/2"PVC P-TRAP. LK-35 BASKET STRAINER WITH 1-1/2"TAILPIECE. B. LONG LEAD TIME ITEMS THAT MAY IMPACT THE PROJECT SCHEDULE MUST BE COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION. LOOSE KEY QUARTER TURN ANGLE STOP VALVES WITH FLEXIBLE RISERS. INSTALL A CHRONOMITE M-30L/277 IDENTIFIED ALONG WITH THE SCHEDULE IMPACT AT TIME OF BID. FAILURE TO -SAN- SOIL OR WASTE ABOVE FLOOR INSTANTANEOUS MICROPROCESSOR CONTROLLED WATER HEATER BELOW THE SINK,277V. 8320 WATT,30 AMP CAPABLE OF COMMUNICATE LEAD TIME ISSUES WILL RESULT IN THE CONTRACTOR,AT HIS EXPENSE, --SAN-- SOIL OR WASTE BELOW FLOOR ALL WALL-HUNG FIXTURES FURNISHED WITHOUT CARRIERS SHALL BE INSTALLED WITH THROUGH BOLTS SECURED TO A FLAT TEMPERATURE RISE OF 71 DEGREES F AT 0.80 GPM FLOW,0.35 GPM ACTIVATION FLOW AND FACTORY SET TO 110 DEGREES PROVIDING TEMPORARY FIXTURES OR EQUIPMENT TO ALLOW FOR SCHEDULED TENANT IRON PLATE SET ON OPPOSITE SIDE OF WALL INSIDE PLUMBING CHASE. EXPANSION BOLTS SHALL BE USED FOR BRICK OR F. PROVIDE TRUBRO INSULATION KIT FOR HOT WATER AND DRAIN PIPING. ALL PIPING AND EQUIPMENT SHALL BE HELD OCCUPANCY_ THE TENANT/DESIGN TEAM WILL CONSIDER ALTERNATE PRODUCT ST STORM LINE ABOVE FLOOR CONCRETE WALLS WHERE THROUGH BOLTS CANNOT BE USED. EXPANSION BOLTS SHALL BE USED FOR BRICK OR TIGHT TO BACK OF CABINET SO AS NOT TO EXTEND INTO ADA KNEE SPACE. ELECTRICAL CONNECTIONS BY ELECTRICAL SUGGESTIONS BY THE CONTRACTOR(IF SUBMITTED PRIOR TO BID)TO MAINTAIN THE --ST-- STORM LINE BELOW FLOOR CONCRETE WALLS WHERE THROUGH BOLTS CANNOT BE USED. EXPANSION BOLTS SHALL BE"HILTI"SYSTEM OR SIMILAR CONTRACTOR, SCHEDULE. Z AND INSTALLED PER MANUFACTURES GUIDELINES AND INSTALLATION INSTRUCTIONS. S SUB-SOIL DRAIN TILE ry� SINK-STAINLESS STEEL-SINGLE COMPARTMENT-ADA-INSTANTANEOUS HEATER -(S-2) 03 ALL FAUCETS SHALL BE FURNISHED AND INSTALLED WITH UNION TAILPIECES FOR CONNECTION TO SUPPLIES. SLIP JOINTS G KITCHEN GREASE WASTE LINE OR GASKETED JOINTS WILL NOT BE PERMITTED. ELKAY#GECR-2521, 25"X 21-1/4"SINGLE COMPARTMENT 20 GAUGE STAINLESS STEEL SINK 5-318"DEEP,WITH 3 HOLE - SIOIG - SAND/011JGREASE WASTE ABOVE FLOOR M PUNCHING. DELTA FAUCET#470-DST-WE, 1.5 GPM, SINGLE HANDLE PULL-OUT SERIES WITH THREE HOLE MOUNTING AND 1 ALL FIXTURES SHALL BE INDEPENDENTLY VALVED WITH EITHER INTEGRAL STOPS, CONCEALED STOPS OR STOPS BELOW THE CHROME FINISH(P C. SHALL ENSURE THAT PULL-OUT HOSE HAS UNOBSTRUCTED TRAVEL AREA AND DOES NOT BECOME -- SIO/G SAND/OIL/GREASE WASTE BELOW FLOOR J^ FIXTURES. ALL PLUMBING FIXTURES SHALL HAVE CHROME PLATED BRASS TRIM UNLESS OTHERWISE SPECIFIED.. ENTANGLED ON VALVES, PIPING AND/OR ACCESSORIES INSTALLED BELOW SINK). 1-1/2"PVC P-TRAP. LK-35 BASKET --- VENT LINE LL STRAINER WITH 1-1/2"TAILPIECE. QUARTER TURN LOOSE KEY ANGLE STOP VALVES WITH FLEXIBLE RISERS. INSTALL A FIXTURES SHALL BE FURNISHED AS INDICATED ON THE DRAWINGS."BASIS OF DESIGN"IS AMERICAN STANDARD, SIMILAR AND CHRONOMITE M-30L/277 INSTANTANEOUS MICROPROCESSOR CONTROLLED WATER HEATER BELOW THE SINK,277V, 8320 AR ACID RESISTANT WASTE EQUAL CHINA FIXTURES MANUFACTURED BY KOHLER,CRANE, TOTO,AND ELJER WILL BE ACCEPTABLE FOR REVIEW BY THE WATT, 30 AMP CAPABLE OF TEMPERATURE RISE OF 71 DEGREES F AT 0.80 GPM FLOW.0.35 GPM ACTIVATION FLOW AND ___qR___ ACID RESISTANT VENT LINE ENGINEER. THE SUBSTITUTION REQUEST FORM IS NOT REQUIRED FOR ALTERNATE MANUFACTURES UNLESS NOTES FACTORY SET TO 110 DEGREES F. PROVIDE TRUBRO INSULATION KIT FOR HOT WATER AND DRAIN PIPING. ALL PIPING AND DATE 05/23/2018 SPECIFICALLY STATE"NO SUBSTITUTIONS". SIMILAR AND EQUAL STAINLESS STEEL FIXTURES BY JUST WILL BE ACCEPTABLE EQUIPMENT SHALL BE HELD TIGHT TO BACK OF CABINET SO AS NOT TO EXTEND INTO ADA KNEE SPACE. ELECTRICAL PD PUMP DISCHARGE I FOR REVIEW. SIMILAR AND EQUAL TERRAZZO OR MOLDED STONE PRODUCTS BY STERN WILLIAMS AND SWAN WILL BE CONNECTIONS BY ELECTRICAL CONTRACTOR. SCALE AS NOTED ACCEPTABLE FOR REVIEW, COLD WATER LINE(C.W.) FAUCETS OF SIMILAR DESIGN AND EQUAL QUALITY TO THAT SPECIFIED BY KOHLER, MOEN, CHICAGO FAUCET,TBS BRASS, HOT WATER LINE(H.W.) MGR JRA ZURN,AND SYMMONS WILL BE ACCEPTABLE FOR REVIEW. THE SUBSTITUTION REQUEST FORM IS NOT REQUIRED FOR HOT WATER RETURN LINE(H.W.R.) I ALTERNATE MANUFACTURES UNLESS NOTES SPECIFICALLY STATE"NO SUBSTITUTIONS" F- FIRE OR SPRINKLER LINE JOB CEN014 FIXTURES SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS. PLUMBING FIXTURES,TRIM AND RELATED -PCW-- FILTERED COLD WATER SHEET APPURTENANCES AND FLOOR DRAINS LISTED IN THE FIXTURE SCHEDULE ARE SELECTED TO ESTABLISH THE BASIS OF - TYPE(E) - EXISTING PIPING DESIGN AND A LEVEL OF QUALITY EXPECTED. p.100 --TYPE-- PIPE TO BE REMOVED OF SHEETS IHDL DESIGN HEREBY!EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE T TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I REVISIONS BY � • N O a a g v l' . pC O O r: — O Z :se',cj Z V O F- sn1:1 itj M D Z .. U L Z V W od _ Ce r z IL0 Z 0 6Z 3 c • '4 o {•7 V Z r"- H i r-- v Z gm (i o -g W Qin uA.0 ., •�O 6 oo m 2 >- ��r 0 Z d Q !) ❑ 0 � M �, FAUCET SHALL HAVE CONTROLS 0 c °C ^ n °v 24" MAX FROM FRONT FACE OF Z v FF COUNTERTOP, COORDINATE U °=°% -c,- WITH ARCH. 5 .a ,E,__ 3 o_ -0 v SEE ARCH ,' 03 �C Q o I..IIm ■ - -v z SINK SEE — ���`�N � � io s2 SCHEDULE GyN vca 7 ti 7. 3 PE Irill V 5 5,4.. et - lik"(/'Y 8,2.°°'\ '<el 11 I \ a l 1 W 0 CD MIN. \ \ LirTJ a l a T 34" l W� N M ETER F11112 P�G0 E MAX. l I�ERMO� To 5�� MIN. OR ADA REQUIRED 27" ADA KNEE SKIRT �1 CLE� �- WIDTH FCE LL W0 U SINK FPG °G� BASE CABINET) TG 51(Jn \f P-�E WITHCOORDINATERCH `-�SGP 11" / 6"—71,1 MIN. MAX 1 0" 1 10R P ADA REQUIRED 1E OLE) 5Tr` SER r�SGIEQ CLEARANCE ��5 V� T�RE AIse Ne NO F NOTE: IN!�et, WHERE APPLICABLE, LOCATE MIXING VALVES, WATER FILTERS, BACKFLOW (5E PREVENTERS AND ECT. AS TO MAINTAIN THE REQUIRED ADA CLEARANCE. 1 SINK H.W. SCHEMATIC 2 A.D.A. KITCHEN SINK M P-101 NO SCALE P-101 NO SCALE . o 5Wca Ze.o ., § erIN la 5..,- � 6 �° Z W 3F v t/ l 41. 1 ADA REQUIRED l CLEARANCE \ -;q - ICE MACHINE DRAIN \ (COORDINATE SIZE WITH MANFACTURER) BY P.0 CYm" EXISTING HUB DRAIN IN—� SINK BASE CABINET - - - -I N t 1 I V f AIR GAP 1• FIN. FLOOR JOSAM 58510 JM 01 . tWALL ACCESS CLEANOUT COVER . . . . ' - . _ ... . TEE WITH PLUG r I I 111111 — WATER SEAL ________ VENTED WASTE AND DEEP SEAL "P" TRAP -C2 _. CD 3 HUB DRAIN DETAIL 4 WALL CLEANOUT DETAIL J P-101 NO SCALE P 101 I NO SCALE L 0 0 0 MZ m D J CL DATE 05/23/2018 SCALE AS NOTED MGR JRA JOB CEN014 SHEET ID1O1 OF SHEETS w IHDL DESIGN HEREBY'EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN FERMI SION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I REVISIONS BY I co 0 r Ng it 2'a u.�oz F- , z- zj �C• } (7). � El I_z.l -I od c n 3g z0 6 z ) z e L § 3 ZM i= V / .z5 o U co n n O ____-.001 ! r CEDC-9) z ^ U W Z {• _ o ° t ° ° t\ J 0 e ; f on �nooO ci u . a y /y p1� ,7,2///72Y-///,-/,../<'<'<),'',.<2,2-%>211 '>)2%////),1<%%%,-<1111////,'1,'/ ,>,%,!, /,'/,' iiiiiiiiii / r �•// � 7 „:„. _. 0 • u J U SW - . - i! _.. :: E = IF 7-111i M t=3 I '; Mil : / 0 0 M ///////// ZVI U ch o r/ ' ' a i___, 6 a il. (0) Oil3 ___ _____ .____ (Ifiyr •VAVYA(J///• ,../y ,O, „,. z ,,,,r , . . . . ' 1731 1 1 1 a .)) L.----3 r--.1 L-----J r , ..1,-,ve _ . :/// y , , :7 : :, , , ,--7-7----- , 1 11 111 I I _ _ .....„ „_,( LL 1 , I ' /.1 1 INI U =;" / • ' A //r// rr 7 :533PE i 1. ,... ..i / ,r- . //////7 , ; ://,':///- 4,: /1 1 V I ' ' A / , #i'd1.1\IA •Q:1 -----1 ./ o _ t,,f A T `L, L /. X /: ..w.."-G-c:0 - 4//,./' / MAY 2 3 2013 1 1 . 11 Lold )41 , _.. / 4 . , w IT(‘ NiLi, , i i__11_ ... ____ _11-1 (.‘ 7 mg - - - - - . .. , , , , . ... , , , , , . . . . . ._ z-'.X V ,,:v / " ',.>.- " " - - --,v ® , u u IL> - II ://. ,, //, „7/./...,2>x,/,,, -../..„›,,,,/, -....////////:.7 ,,,,,,,, ,, Ay tia c_4. < ... i 1 / olot:A : , / / 4 7/./2,/,,, / ffIlf</ i ''j '''',/ ; / / 1---/7 ,f , ,, , , . // 0,0,/ P.,/:. 1• / / �i��ii �i�I�/moi 1/ :*' I /,_ _ _ I A, A gr , ,• , , „ , , 11"31111L- 14. / // , , z ,, y / �y I jo, ',. // / '/I ,rAtistmal /f ,/ /�iii� /. r,,r ///.r , , la 0 r, / / // // //, //./..”, .. . . . . . /0 /4A4_ ,I� ,/ 1 8 / , /4, ire ' _.-5 1 1 i /7////, • _ ; 7 „ . . ) IL , 1 fr .41 „,), - , ,• _. I . , .//g/-4f / /1 .. / ';'- . ,.. „ , _ •All //'” //1/ ''',./ J /' /,',i1 / , — 0 /./ i4 ... , A4 / 00 4 / / /i i/ • '6. „ „// __ . -* , 5 Ork,..A. ' fc , / "/ //// // // 111—> zz ,Y.,/Y. ,/ // , /10).( �/1 ._---_/ Fr,/7. Pe' " 64 / ; "\, 1 1 „ „ „ „ _ , 1 — , -,/8, I , . -®Bax '�/ j //// A7 V 0 e.,44! 1invo f�c� 5B0 T- ,_ =7.,___ 11 I' ''// / ��j/, 4,,/// ,, ,1„ .5,/ / jz- ' irr---- I //// //// / / ���/��. . ji // 7 /-//X l //, .c<<</.5;://4 Z /` 1II / ./7/, .//, I% ' // i. / 11 1 : .;,_ . . . , , , ,/,, _ _ _ _ /./ . . i _ 4 1 1,Ii , -1 ,-, o /• , ,/,,,, /, , :�1 0 , , , 4 1 r 1 / 1 1 :///7;„ • . . L I 1 1 %/A , , .r :.//, , , /" § REF r /,, /:, Ai : , ® O Nu 11 1 1 _.3 , __, - _AI, / . Zt §rr L _ 1 _ 1 , A i ci) Ilirct re 6 i 1 , .. .- — =1 r 7- ',- - 1 -.,, ,,- -,- --- - - '.;,,,,,r. , . , ,, ., , . :, „ . . ...) , _. , . . . r •-• ' . ...... P /. I • Z 1 ' I '/' T 1 , , . ,,,, /,. . _A , r‘ . . „ ._, ,0 %r - ., . . ://). , y ILI >: ,/ 4 ',V ', :;-,V ',/,/ 7,//f :,,. : :,, : J7.- , , ...„ < p :,,7'r. 0 ; 4174 EC) —1 5) , , . . „ . „ „ .///// �.4 4. / 4 /- . /� — — /',,. ;ii iii/i /iii///i/i/i / //ilii, , ,4.,./ // ,,/.. /// ��/ //,//////��/�////��/'////////A ►i /. G / .a au� f//./...//.ff/ -/f. f/.//./. .T/ ///// /�///f/�f///f/,/fff.. /. .CFFt ���7 /' pO • j ,, //r//,/, , //////.r/ / /i/i//iii/i ////f//// /, �'-�1 —�' 3 :/,//////,�//.. . ////// ./ / /,r///r//,�//// f///fir/////�/ /,f //////////111V/1/2//ii �O / `fes . . . . , . . . _ _ . . ! _ . . . BEIO 67,,, toi 0 Fiie 0 <>/\<> -(>7\-<> N 4 Are' ., - , P.:iv //,,,',,, L -<>\/<)- -(X.x<> P III i 0 ® 0 0 D---- w � oEL) 0 CD Z PARTIAL FIFTH FLOOR PLAN - PLUMBING DEMOLITION a_ z N CSCALE: „ _ , o Q PLAN NOTES - PLUMBING DEMOLITION o� E 1. EXISTING SINK TO BE REMOVED. REMOVE ALL UNUSED PORTIONS OF PIPING BACK TO WALL. S J REMOVE ASSOCIATED HW PIPING BACK TO SOURCE. REMOVE ROUGH-INS TO ALLOW 0 INSTALLATION OF NEW ROUGH-INS AND NEW FIXTURES. PATCH WALL TO MATCH EXISTING AS C REQUIRED. W 2. EXISTING SINK TO BE REMOVED. REMOVE ALL UNUSED PORTIONS OF PIPING BACK TO MAINS 0 AND CAP. PATCH WALL TO MATCH EXISTING AS REQUIRED. 03. EXISTING DISHWASHER TO BE REMOVED. REMOVE ALL UNUSED PORTIONS OF PIPING BACK u' Z TO MAINS AND CAP. PATCH WALL TO MATCH EXISTING AS REQUIRED. a 03 M 4. EXISTING ICE MAKER SUPPLY BOX 1N WALL TO BE REMOVED. REMOVE ALL UNUSED PORTIONS P OF PIPING BACK TO MAINS AND CAP. PATCH WALL TO MATCH EXISTING AS REQUIRED. CC J 5. EXISTING HUB DRAIN TO REMAIN IN PLACE AND BE MAINTAINED. < a. IL I 6. EXISTING WATER HEATER ABOVE CEILING TO BE REMOVED. REMOVE ALL UNUSED PORTIONS OF PIPING BACK TO MAINS AND CAP. EXISTING ELECTRIC WATER COOLER TO BE REMOVED. REMOVE ALL UNUSED PORTIONS OF PIPING BACK TO MAINS AND CAP. PATCH WALL TO MATCH DATE EXISTING AS REQUIRED. 05/23/2018 7. EXISTING PLUMBING FIXTURE(S) TO REMAIN IN PLACE AND BE MAINTAINED. SCALE AS NOTED MGR JRA JOB CEN014 SHEET P- 201 OF SHEETS IHDL DESIGN HEREBY EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMISSION OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT. I I I I REVISIONS BY 1 Ca ► 3 4 �►� a:,�r� ZO R S'g ;0 0 0 o � o � ^ r � o Y n ., , a Y 0 ¢ :� Z T 71132 Y Y YI Y Y C Y Y « .. II . - IL L q5 /1 // /42'A '� — '� _ � � � �� �00 OFFICE 4 — — v w f ` c� Z J CI ,: I t II I eft, ! ! I p I,-..I — Cii / �.� y. 0 / z ¢ Z pOr ) ilil. . _„.___ .1i �1 •0 ^ ^ r ,� \�� 4.-"Y4//I / % • i , , , „,://,; . , . _ 4.,• CSL r I= . 1.--j±- =-, ... .. — — — _. ,� _ I CONF. I a L L L1 MOTEL LOLL -• TION �!i� � / , :� 0 z: z M = I _L-: 1�1 + I !�, I�� !�I 5mii 5mm z g rn s r. o a o :. �� 1 .I lid! . . .Jim 0.0 �' , , 1. . L I li it ])) r� �_% 'I / f// '/ z Z ++ I� �7 !--" C ,� �, .. ,., r ll r�' r_' f' % //�.__ �I PLAN NOTES - PLUMBING °� n n IIPIP I.I ! 1 _ I■I I■I3 I■I - MIN I I I.I !.! `J / �,��'��=�,/`��/ cv oc n nt"`Gi, D VOFFIGE 13 o a ! �I NM o © ! '�I �' �� ' 1. SINK AS SCHEDULED AND DETAILED. CONTRACTOR SHALL REWORK PIPING IN WALL AS REQUIRED TO U 1 g o _o INSTALL NEW FIXTURES. CUT AND PATCH WALLS AND FLOORS AS REQUIRED AND MAKE READY FOR NEW _I p, U '-c-1 � 531 - -- _.�. , , , . . , , , OPEN OFFICE FINISHES. o FE 'S/J I wow l V C FE A - c- ,:i, , , _533 jj/ �%J ��' 2. PROVIDE 112"VALVED COLD WATER AND APPROVED BACKFLOW PREVENTOR IN SINK BASE FOR COFFEE ° / � MAKER. EXTEND COPPER TUBING THROUGH BASE CABINETS THEN THROUGH THE COUNTERTOP NEAR � � � . , / .,_T ,. HUDDLE I NUD�LE107-IUD5D3L7E 3 FE Al BACK SPLASH AT COFFEE MAKER LOCATION. PROVIDE 114" O.D. TUBING FOR SINGLE UNIT OR 318" O.D. `--1 1535 Ir�361 �! rMI ce s► , TUBING FOR DOUBLE UNIT. COORDINATE EXACT COFFEE MAKER REQUIREMENTS AND LOCATION WITH �Q� S/ B �FICE1'� ILL1 • P IONS /, / j/ r / p-,;„ . f• ARCHITECT PRIOR TO PLUMBING OR DRILLING HOLE THROUGH QUARTZ COUNTERTOP G.C. SHALL DRILL $, �Ne,1NEG-•,s, * / j ,/rI ;/j i� /� HOLE. ,E r / 53a 539 7. *Zed /� :`�� �, / /• '� /� �� 7• .3 95 l i ■oaf 111 '� = r- - /. 16/ 3. EXISTING HUB DRAIN UNDER SINK. CONNECT TO WASTE PIPING AS SHOWN. CUT AND PATCH WALL AND MiI'1 I �, �' sg `JTQR. �� / / �. '/ ' r FLOOR TO MATCH EXISTING AS REQUIRED FOR INSTALLATION OF NEW PIPING. 1�1 538 moi` `/ /• // /" /� //j/ yi4r/ o ���� ;/, % ////////; /////// 4. PROVIDE 112"VALVED COLD WATER AND APPROVED BACKFLOW PREVENTOR IN 51NK BASE CABINET FOR �L� ; g' tttt� / • j///�j/// �� , i/, / ELEG'r. // , ICEIWATER DISPENSER. INSTALL AND CONNECT G.C. PROVIDED INLINE WATER FILTER IN 51NK BASE,w w ///////// , ' "" `- 2 / /// �_x� MAINTAIN SERVICE CLEARANCES RECOMMENDED BY MANUFACTURER ANb ADA REQUfREd CLEARANCES.REC A ir—Ai �I /� '/' ' ;/ ' - EauIP. NET�uoRK /, -��•� - �PRINT �j P 301 �/. , f ,/ ; �4A ��,�7,t� EXTEND COPPER TUBING THROUGH BASE CABINETS THEN THROUGH THE COUNTERTOP NEAR BACK 7Ar/44:G1211'11:83Q1:4611-12-). / CI 534 iiii- �� / !�! / ' /,�, / / j; .TMJSPLASH AT ICEIWATER DISPENSER LOCATION. PROVIDE 318" BRAIDED STAINLESS STEEL FLEXIBLE SUPPLY -' —_ a yyy/r• ' / �, / �/ ` ;/; f ./ �. �/ ____� � TUBING FOR UNIT. PROVIDE 1" INDIRECT WASTE FROM BIN DRAIN TO FUNNEL FLOOR DRAIN IN SINK BASE, .- Ill 1 d 1] 1 -_ �� � /7 / �,- .f! PROVIDE CODE REQUIRED AIR GAP. PIPE DISPENSER THROUGH BOTTOM OF UNIT. COORDINATE EXACT %i.... .=-.�. € II / /�.►.. ;�; ,`;/// // / DISPENSER REQUIREMENTS WITH G.C. AND MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO �� �I ] 2 Q ] I sok 1 I 1••10T R / =/ �/ / : / I\ NON-ITER CORRIDOR PLUMBING OR DRILLING HOLE THROUGH QUARTZ COUNTERTOP G.C. SHALL DRILL HOLE. CONNECT v / �/ , , o COMPLETE AND READY FOR OPERATION. �� Ci [. ill 3 iy --E9i154m ■ Al ',"////6•4 l/ ' �/ /. 5. PROVIDE 314" FLOODMASTER WATER AUTO SHUT OFF VALVE#RS 094 WITH A1C ADAPTOR, (2) SENSORS AND Z� 0 — �I /, /,/' .f- , . / ./ ,/. CONTROLLER. INSTALL IN SINK BASE CABINET ON ICE/WATER DISPENSER SUPPLY LINE AFTER SHUT-OFF W �" Ci) �� �� ,� /7/////////�_///�'/�. / f// ! /// /j� VALVE AND BEFORE FILTER. CONNECT COMPLETE AND READY FOR OPERATION. COORDINATE WITH E.C. FE OPEN OFFICE _ ��' 1, FOR ELECTRICAL CONNECTION. ■T 528 B>2"W-1 LTL-PJRP05E -'� Z D 2"V�� %" CWD (��� 'r 6. SINK AS SCHEDULED AND DETAILED. CONTRACTOR SHALL PROVIDE NEW PIPING ABOVE CEILING AND J I rtl— . . 4 .. I 522A BELOW FLOOR TO NEW FIXTURE. CUT AND PATCH WALLS AND FLOORS AS REQUIRED AND MAKE READY W o - A _ N.�� A - I - �I _ /% FOR NEW FINISHES. - 0 0lot r 1 r- I C r f L1 I_ \� /7 11 TI >'•-' ) "-";" '-' -"� .� 7. CONNECT NEW 2"VENT AND 2"WASTE TO EXISTING WASTE AND VENT AT THIS LOCATION. CUT AND PATCH i. !. �. [. u� f _ - �- I I '�'` T -+- /'� ` WALLS FLOORS AND CEILING TO MATCH EXISTING AS REQUIRED FOR INSTALLATION OF NEW PIPING. FIELD • EXISTING CW _ HE ':, i;/ VERIFY EXACT SIZE AND LOCATION OF CONNECTIONS PRIOR TO BIDDING. REMOVE AND REINSTALL q h 111 IIJ 1J 0 / EXISTING CEILING TILES AS REQUIRED FOR INSTALLATION OF NEW PIPING COORDINATE ROUTE WITH 1 L...... ._ ] 0 I —I 1171 I I k I7 TRAINING ROO^1 i; : I / PROPERTY MANAGER AND EXISTING CONDITIONS. — a` e p o v 523 i. ,, I, "<>0> — 1 _ _ i. I rmnri n rJ 0 n ii 4,,:.z 8. CONNECT NEW 112"CW TO EXISTING WATER AT THIS LOCATION. CUT AND PATCH WALLS FLOORS AND �,- �.- .. �.- �.- ° I {.- „I .- �.- ' . ��• ./' CEILING TO MATCH EXISTING AS REQUIRED FOR INSTALLATION OF NEW PIPING. FIELD VERIFY EXACT SIZE W 7 -7STORAGE ° r 1 h 0 ` AND LOCATION OF CONNECTIONS PRIOR TO BIDDING. REMOVE AND REINSTALL EXISTING CEILING TILES AS �, ❑ iii. "r REQUIRED FOR INSTALLATION OF NEW PIPING, COORDINATE ROUTE WITH PROPERTY MANAGER AND 54. 1t■■ R11111■ 1� ► I INN ► �� �� A t y �. BREAK 111 .. ._ t� p Illi t 1 I Illi , I■ EXISTING CONDITIONS. , 7, EXISTING C h 0 . I I 522 j '�`i - I I I _ REF 1 ;. _I__. <>0<?- / di, - GENERAL NOTES FIRE PROTECTION c O II .7/7 j �Ir,,, / �. j /' II �� `� % n n n P 301 I A. ADJUST AUTOMATIC SPRINKLER HEAD LOCATIONS AS REQUIRED, THRU THE USE OF NEW SWING ARMS Al A= � �I , .% / / I G ' 1 / / 1�1' p N I°f 11111 '� �L►L �1!L" 529 / / / / ff_Aubp, I' 1 ri in . -- AND DROPS, TO MEET THE SPACING REQUIREMENTS OF NEPA 13 FOR HYDRAULICALLY CALCULATED ��� ��� ' / _— � + ��I� `� rf�/ LIGHT HAZARD SPRINKLER SYSTEMS" WHERE NOT PRACTICAL OR POSSIBLE TO USE A SWING ARM, g ik _ ,7 . { ir-H r��� / E? ;, % / ri I�I I I is fir REWORK EXISTING BRANCH LINE PIPING AS REQUIRED. REFER TO MECHANICAL AND ELECTRICAL PLANS % /; / /,,% , ■ �� FOR CEILING MOUNTED ITEMS TO COORDINATE WITH.• / Irrr� '+'ai�� tv I I l ! _+Iwo [•l Ina _ O t �` I ., I I 0 /; /�/•// /////////// /// //// i r��`i���, /.'�_, /�i'a ///- / B. ADJUST LOCATION OF BRANCH AND MAIN PIPING AS REQUIRED TO AVOID INTERFERENCE WITH THE w1 C — /'ii, ,iii, rlrir rr. 1 —l: rt rtnn ,,,,,,,,,,i \J 1111-4 ��%�/ /f/!!! !!!!!!!!! .!•_/.! !!!!! !!! !!!!! � �i ��+, '� ��� /„..„,44 HE . " . INSTALLATION OF MECHANICAL EQUIPMENT INSTALLED ABOVE CEILINGS. Zr,CL3 §rNi Eno oi Pl ' 40- -<> 5..._, cz LAI / %s I�''�I� j� Iii iii �I - - „ ,/ �,' 1 Z 1 _ _ ---------- ,,,,,,�, „ a 1 W a � F _ BREAK C— i n 522 E < 0:.) U c3) 0 0 _� �_� , = 0 7 11 o tL a-1 0 FLOOR PLAN - PLUMBING L . S-1 ( 1 PARTIAL FIFTH 00 _ N , SCALE: 1/8” = 1' 0" 1 3 1.::2.01 I 3 I EE N 1 r BALL VALVE TYPICAL . a ., , . REF 1 -EXISTING CW P-101 I SEE FLOOR PLAN _..4.!:..__+ I Z WATER HAMMER 2"---\ �„ ARRESTOR TYPICAL Lr' 523 FOR CONTINUATION I LJ L TRAINING ROOMlila L,- n Lr WATER LEAK SENSOR `J SEE FLOOR PLAN 523 INSTALLED ON FLOOR OF SINK %'i �`� FOR CONTINUATIONCr SANS IN REAR CORNER, ROUTE COFFEE 1 ENLARGED BREAK ROOM SENSOR WIRE TO VALVE �� , .7_14" Q EXISTING VENT- ACTUATOR IN SINK BASE S-1 �', OF ICEIWATER 1 P-301 SCALE: 1/4" = 1'-0" v DISPENSER , © • ^ o P-101 ,, LL BALI VALVE TYPICAL STOW / 1 WATER HAMMER TO / AUTO SHUT OFF ARRESTOR TYPICAL / 0 • VALVE INSTALLED WCO `� I ' LL Z IN SINK BASE 1/2'“ J m FILTER PROVIDED BY G.C. !� WATER LEAK SENSOR INSTALLED 1 /z D/ CW- ,\,:i 2 S=2 Q j INSTALLED BY P.C. IN SINK BASE ON FLOOR OF BASE CABINET P-101 S-2 I jC0 2 S 1BELOW ICEIWATER DISPENSER IN I P-101 yi."):-..,........ REAR CORNER, ROUTE SENSOR - 2" S-2 4 MOTHER S Fr Q1 WIRE IN CABINETS TO VALVE nP-301 / ICE/WATER ACTUATOR IN SINK BASE V 11_1II ROOM C / n.. 54m / \I� DISPENSER U >2"W-J P---E1---P � ' 3 7EXISTING HUB DRAIN J O J�2" 173I P-101 Y I \\� / ` 05/23/2018 - ROUTE ICE MACHINE DRAIN SEE FLOOR PLAN D 1 \ IN WALL TO HUB DRAIN FOR CONTINUATION C 2 V-�I � , EXISTING WASTE - , ,�� I I / / SCALE AS NOTED I, `, OPEN OFFICE 3 FEMGR JRA 4 MOTHER'S ROOM 540 RISER DIAGRAMJOB { 3 BREAK ROOM 522 RISER DIAGRAM CEN014 P-301 NO SCALE 2 ENLARGED MOTHERS ROOM P-301 NO SCALE SHEET P-301 SCALE: 1/4"= 1-0" P-301 OF SHEETS - IHDL DESIGN HEREBYI EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE IT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM DR MANNER WHATSOEVER WITHOUT OBTAINING THE EXPRESSED WRITTEN PERMIIS1DN OF HDL DESIGN NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING WRITTEN PERMISSION AND CONSENT.