Loading...
Plans (47) FPS2O19-00132 J CUSTOMER NAME: _ - - McKINSTRY _ 16790 NE Mayson St. Suite100 Portland, OR 97230 ._ ,. , , AT& T NIMBUS t I I 4 -__-.- i 7 - „xi .iiii-------"N 7,P- -'',crie''',1^/, ,A 1- L' L a i - � 1 Cor . . nt .:..70-'''' TEC ._ a a - ES TEG - • • 1 ES 7678 SW Mohawk St,Tualatin,OR 97062 Phone:503-228-8522 Fax:503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. RECEI VED OCT 17 2019 Fire Alarm System •• ITY OF TiuARO BUILDING L"iVISIGN New Installation PLEASE PROVIDE COMPLETED NFPA 72 RECORD OF SYMBOL LEGEND GENERAL NOTES DESIGN INTENT DEVICE LABEL SCHEME DRAWING INDEX COMPLETION AT I. Noon' xa• ro R AIGxtC FINAL INSPECTION 1 awv 6 ammo xar NL WAGES 9101•WT ff rlRs[xr RIMS SYMBOL2 DESCRIPTION MODEL 1 BACK BOX / DIMENSIONS 1. ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. BUILDING CONSTRUCTION CONDITIONS: SIGNALING UNE CIRCUIT DEVICES: Drawing Number Drawing Title - 0 MULTI-CANDELA STROBE GL1RF-VMC APPLIANCE: 4.53'H x 2.76'W x 1.27b • OCCUPANCY B. S-2 •me avow RAMC TRIMPLATE ALL WIRE AND CABLE MUST BE RATED FOR FIRE CODE SECTION RE ALARM USE PER THE LATEST REVISIONS OF THE NATIONAL ELECTRICALYY - XX - ZZZZ XX ••u!_ RT 1u�OTHERWISE NrCATm TRIMPLATE 5 25'H x 4.581M x 0.32b • LOW-RISE 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. •c CUM RoaRr FULLY SPRINKLED FAO.1 FIRE ALARM COVER SHEET •WA rEeTI.RVRoor • HORN/STROBE NOTIFICATION DEVICE NUMBER OFFICE.COPY 3. ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL • GENERAL ALARM EVACUATION LOOP NUMBER CI`T'Y OFGAItD MULTI-CANDELAHORN/STROBE GL1RF-HDVMC APPLIANCE: 4.53'H x 2.76'W x 1.27bFA1.1 FIRST FLOOR FIRE ALARM PLAN alXX • TRIMPLATE: 5.25'H x 4.58"W x 0.32"D 4. TO RETAIN WARRANTY, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF QUALIFIED MANUFACTURERS PANEL NUMBER (IF NETWORK SYSTEM) FA1.2 FIRST FLOOR VESDA PIPING PLAN �`- •WA WEA HE OTHERWISE 'M OREGON STRUCTURAL SPECIALTY CODE: 2014 ED. E V tL'W CD FOR CODE COMPLIANCE •a aauxc WHAT WG4WF-SVMC (WEATHERPROOF) 4-SQ W/ WFP-W MOUNTING PLATE TECHNICIAN. HORN & STROBE NOTIFICATION DEVICES: •wr.wuTRarPRoar OREGON FIRE CODE: 2014 ED. FA2.1 FIRE ALARM RISER DIAGRAM _ ® ADDRESSABLE PHOTOELECTRIC SIGA-PD 3-OCT, 1-1/2" DEEP & 3' MUD RING 5. THE UFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. OREGON MECHANICAL CODE: 2014 ED. SMOKE / FIRE ALARM & SIGNALING CODE, NFPA 72: 2013 ED. BPSx - 01 •• • IN-DUCT DETECTOR SIGA-SB (STANDARD BASE) BY EC. FA3.1 FIRE ALARM CONTROL PANEL WIRING DETAIL & BATTERY CALCULATIONS Approve& i •HQ HIGH T MOF,NGNAY�0. 6. INSTALLING CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH CONVERGINT TECHNOLOGIES INCLUDING, BUT NOT FATTED TO, TT •UF:xaur Ep N Ag1ERnaaR SPACE CHANGES IN DEVICES, WIRE, AND OPERATION IN THE SYSTEM. CONVERGINT TECHNOLOGIES SHALL NOT BE HEW RESPONSIBLE FOR CIRCUIT NUMBER 3 I G t , UNDOCUMENTED CHANGES, OR THE RESULTS CAUSED BY THOSE CHANGES. 24VDC CIRCUIT IDENTIFIER FA3.3 TYPICAL WIRING OF FIRE ALARM FIELD DEVICES i ' ADDRESSABLECMPHOTOELECTRIC SIGH-SD SELF-CONTAINED ABBREVIATIONS LEGEND (E.G. FACP OR BOOSTER POWER SUPPLY FA3.4 VESDA WIRING, MOUNTING & POWER SUPPLY DETAILS ettnjt#2 FP,‹,r1) g- (NQ J�'� ') DUCT SMOKE DETECTOR 7. PUBLIC MODE UFE SAFETY AUDIBLE TONES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL HAVE A SOUND PRESSURE LEVEL ) ` NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED 10'-0' FROM THE DEVICE& 5'-0' ABOVE FINISHED FLOOR. O ADDRESSABLE THERMAL DETECTOR SIGA-HRD 3-OCT, 1-1/2' DEEP & 3" MUD RING Address: , (40 h)...Art 1_ c., ` • RR •RATE°r USE FOR"°"EiETvroR APPIIlAnoxs SIGA-SB (STANDARD BASE) BY E.C. 8. NOTIFICATION CIRCUITS SHALL BE CLASS "B" IN CONFIGURATION. SIGNALING LINE CIRCUITS SHALL BE CLASS 'A" IN CONFIGURATION. FIRE ALARM DEVICE ABBREVIATIONS: /'1 o AC = ABOVE CEILING )U1te#i zC = CEILING MOUNTED O ADDRESSABLE THERMAL DETECTOR SIGH-HED 3-OCT, 1-1/2' DEEP & 3' MUD RING 9. LOCATE ALL PULL STATIONS AND AUDIO/VISUAL UNITS AT SPECIFIED HEIGHTS PER NFPA 72 AND ADA SEE MOUNTING HEIGHTS DETAIL F •FIXED TDPERTURG use FOR ELEVATOR SHUNT TRIP ON SHEET FA3.3. E = EXISTING TO REMAIN 1 44 SIGH-SB (STANDARD BASE) BY E.C. - Bys Date:���� Z. R = EXISTING TO RELOCATE i h0 DOOR HOLDERS 1504-AQN5 SINGLE-GANG, 2' DEEP BY EC. 10. SMOKE DETECTOR LOCATIONS ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NFPA 72. N = NEW DEVICE • O •r PRN.RT COMMA' X = DEMOLISHED DEVICE ❑F ADDRESSABLE MANUAL PULL STATION SIGA-278 SINGLE GANG, 2-1/2' DEEP BY E.C. 11. SMOKE DETECTORS ON CEILINGS MUST BE NO MORE THAN 15' FROM A WALL AND/OR NO MORE THAN 30' FROM EACH OTHER. EXCEPT WP = WEATHERPROOF • IN NARROW CORRIDORS OR IRREGULAR SPACES. UF = UNDERFLOOR .. )z ❑S ADDRESSABLE SIGNAL MODULE SIGH-CCI DOUBLE-GANG, 2-1/2' DEEP BY E.C. 12. ALL FIRE ALARM DEVICES SHALL BE RIGIDLY AND SECURELY FASTENED TO WALLS OR CEILINGS. FIRE ALARM GENERAL ABBREVIATIONS: • SIGA-MCC1 MOUNTED IN MFC/A ON SIGH-U106(R) AFF = ABOVE FINISHED FLOOR WIRE CODE o 13. NO SMOKE DETECTOR OR HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36'TO ANY AIR REGISTER, DIFFUSER, FLUORESCENT UGHT AHJ = AUTHORITY HAVING JURISDICTION o ® ADDRESSABLE SIGNAL MODULE w/ SYNC SIGA-CC1S DOUBLE-GANG, 2-1/2' DEEP BY E.C. OR CEILING FAN BLADE. ALM =ALARM ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE BMS =BUILDING MANAGEMENT SYSTEMz WITH CURRENT RELEVENT NATIONAL ELECTRICAL CODE ARTICLES SIGA-ADDIS MOUNTED IN MFC/A ON SIGA-U106(R) 14 NO HEAT DETECTOR MALL BE LOCATED CLOSER THAN 36' TO ANY PART OF ANY HEAT GENERATING DEVICE (FUSES, BOILERS, WATER EOL = END OF UNE AND RELATED SECTION CODE REQUIREMENTS. 91 4 LEA z HEATERS, ETC.) E.C. =ELECTRICAL CONTRACTOR MADDRESSABLE INPUT MODULE SIGA-CT1 SINGLE-GANG, 2-1/? DEEP BY E.C. HR = N WIRING INSTALLATION NOTES: MAX =MAXIMUMAXIMU M GENE DURNIN L 15. HEAT DETECTORS ACCOMPANYING ELEVATOR SPRINKLER HEADS SHALL BE MOUNTED WITHIN 24' OF ASSOCIATED HEAD. ONE DETECTOR MIN = MINIMUM • LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND © ADDRESSABLE DUAL INPUT MODULE SIGH-CO2 SINGLE-GANG, 2-1/2' DEEP BY E.C. PER HEAD. DESCRIPTION. 73 N/A =NOT APPUCABLE • LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT Digitally signed by Eugene Durnin c, SIGA-MCT2 MOUNTED IN MFC/A ON SIGA-UI06(R) NAC = NOTIFICATION APPLIANCE CIRCUIT NUMBER TAG AND DESCRIPTION. �1 1(�) DN:C=US, 16. INITIATING AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME CONDUIT/RACEWAY/RISER IF ALLOWED BY NEC. NIC = NOT IN CONTRACT • LABEL ALL NETWORK, ANNUNCIATOR AND I/O CONTROL CIRCUIT / �I / E=gene.durnln@converglnt.com, r, ® ADDRESSABLE CONTROL RELAY: HIGH VOLTAGE SIGA-CRH 4-SQ, 2-1/8' BY E.C. NTS = NOT TO SCALE WIRING WITH CIRCUIT NUMBER TAG AND DESCRIPTION. L ,C� � O=Convergint Technologies LLC, 17, ALL CONDUCTORS SHALL BE LABELED BY CIRCUIT/ZONE AND ALL COLOR CODES SHALL MATCH. SLC = SIGNALING UNE CIRCUIT • ALL WIRING BETWEEN BUILDINGS SHALL BE RATED FOR CNEU ene DUmin o © ADDRESSABLE CONTROL RELAY: LOW VOLTAGE SIGA-CR SINGLE-GANG, 2-1/2' DEEP BY E.C. SUP =SUPERVISORYUNDERGROUND USE. Date:2019.01.14 17:54:08-08'00' ~ SIGA-U106(R 18. THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY TRB =TROUBLE SIGA-MCR MOUNTED IN MFCA ON / ( ) AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO TYP = TYPICAL LETTER TYPE USE a CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. UON =UNLESS OTHERWISE NOTED IM LINE ISOLATION MODULE SIGA-IM DOUBLE-GANG, 2-1/Y DEEP BY E.C. A 1 PAIR 18 AWG. TWISTED FPLP DATA LOOP / NETWORK WIRE SCHEDULE 0 19. ALL WORK SHOWN SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES, ORDINANCES, ETC. - B 2 PAIR 20 AWG. RS-232 _ _ ® NON ADDRESSABLE REMOTE RELAY RIC-1/RIC 2 SPUD MOUNT 20. CONVERGINT TECHNOLOGIES STRONGLY RECOMMENDS AGAINST THE USE OF STAPLES TO SECURE UFE SAFETY CABLES. C 1 PAIR 14 AWG. TWISTED FPLP STROBE CKT/ 24VDCRE USE JB FIELD WIRING JUNCTION BOX BY OTHERS SIZE PER NEC REQUIREMENTS E 1 PAIR 18 AWG. TWISTED FPLP AUDIO CKT A 1 PAIR 18 AWG.TWISTED FPLP DATA LOOP/NETWORK I ❑ 21. PER NFPA 72 17.7.1.11.3, ALL SMOKE & HEAT DETECTORS NOT REQUIRED FOR CONSTRUCTION SHALL BE INSTALLED AFTER ALL OTHER ---------- o TRADES HAVE COMPLETED THEIR CLEANUP PROTOCOLS. WHERE DETECTORS ARE ALREADY INSTALLED, THEY SHALL BE PROTECTED FROM B 2 PAIR 20 AWG. RS-232 - j RL RELEASING MODULE SIGA-REL MOUNTED IN MFC/A DUST, DIRT & DEBRIS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. - - C 1 PAIR 14 AWG.TWINED FPLP FACP CKT/24VOC E 1 PAIR 18 AWG.TWISTED FPLP I AUDIO CKT 0- R ABORT SWITCH RELA-ABT SINGLE-GANG, 2-1/2' DEEP BY E.G. FIRE ALARM FUNCTIONAL MATRIX I 3 s-cSSEE FA0.1 FOR WIRE SCHEDULE NOTES& GUIDELINES. 0 ® MANUAL RELEASE 276A-REL SINGLE-GANG. 2-1/2' DEEP BY E.C. s x Q v ® SERVICE DISCONNECT RELA-SRV-1 SINGLE-GANG, 2-1/2' DEEP BY E.C. \PCe \kl- ° �oi°c REVISIONS ISIONS N �°°o �c° C.'• ,°c poi, y'�°�° i a°3c I REV DESCRIPTION DATE APPROVED ANN FIRE ALARM ANNUNCIATOR RLCD-CR SEE DETAIL SHEET c ° 5 I i °� o° .3,"° c o� �S°� �0c o� a CP o FACP FIRE ALARM CONTROL PANEL 101000RD SEE DETAIL SHEET `�°o°c °°a��o< o6 V'e' occ oma° o�¢� ••co moz° e,, I G°�,c \EDC SLP. 0•c� \x° &.' cp;' ja c`'o Q- e J c' Q- o o * o I Y [FDB FACP DOCUMENTS SPACE-SSU00685 FAD: 13"H x 12"W x 2.25"D o��° co 6v- Q`oca Cr 5° yob ,°gym ,�v 4°c ��� o �•P�o\e c�opo •`�Q o�• cr °a Ce .� 0e m APS AUXILIARY POWER SUPPLY 6.5 AMP AUXILIARY POWER SUPPLY SEE DETAIL SHEET c�oQ°� ��e� °FPG ?°� ��°J h�� �°P Q Q�• ,P4 VEP4 VESDA ASPIRATING SMOKE DETECTOR VEP-A00-P SEE DETAIL SHEET M I � � • P° Pc Pc\°° 5m c F¢' P° Q° 4° DRAWN BY: Q. LANG Z anus ul S a ion • • • O Smoke Detector • • • I PROJECT ENGINEER: B.DUFFEL VEP1 VESDA ASPIRATING SMOKE DETECTOR VEP-A00-1P SEE DETAIL SHEET Heat Detector • • • PROJECT MANAGER: G.DURNIN o Duct Detector I • • H [MEG ACCESSORY CABINET MFC-A 8"H x 141W x 3.5"D JOB NUMBER 302FNHO401 I Q VESDA Aspirating Smoke Detector Fire 2 • I • • • SHOP DRAWING SUBMITTAL DATE: 01/I I/20I9 3 I b FLOW/TAMPER/PN SWITCH/LOW AIR BY OTHERS VESDA Aspirating Smoke Detector Fire 1 • I • CONTRACT TYPE: PLANS 8 SPEC:0 DESIGN BUILD: 13 VESDA Aspirating Smoke Detector Alert • • 4.>-• SMOKE DAMPER or FIRE/SMOKE DAMPER BY OTHERS VESDA Aspiratin Smoke Detector Fault • • PROJECT NAME: VESDA Power Stpply • I • WATERFLOW BELL BY OTHERS Pre-Action Abort Station I I • Pre-Action Service Disconnect Switch I I • Pre-Action Manual Release Station • I I • I AT & T NIMBUS Dry System Low or High Air J • • 10340 SW Nimbus Ave Waterflow Switch • I I • • I • I Tamper Switch I • • a System Trouble • I • I I Tigard, OR 97223 SCOPE STATEMENT MATRIX NOTES: A. MATRIX HAS BEEN UPDATED TO REFLECT PRE-ACTION ACTIVATION SEQUENCE. SHEET NAME: FIRE ALARM SYSTEM DESIGN PROPOSED IS FOR COMPLETE SYSTEM REPLACEMENT, THE FOLLOWING SYSTEM PERFORMANCE UPGRADES SHALL BE B. ABORT STATION PAUSES THE PRE-ACTION SEQUENCE. IT DOES NOT CANCEL THE PRE-ACTION SEQUENCE. MADE: • INSTALLATION OF NEW ADDRESSABLE FIRE ALARM CONTROL PANEL '-,--,E ' • COMPLETE REPLACEMENT OF CONVENTIONAL SPOT-TYPE SMOKE DETECTORS WITH NEW VESDA EARLY SMOKE DETECTION SYSTEM IN DATA WALL o &ASSOCIATED MECHANICAL ROOM; FIRE ALARM COVER SHEET • REPLACEMENT OF ALL OFFICE AREA CONVENTIONAL SPOT-TYPE SMOKE DETECTORS WITH NEW ADDRESSABLE PHOTOELECTRIC SMOKE DETECTORS; o • INSTALLATION OF NEW ADDRESSABLE PRE-ACTION RELEASING MODULE: m INCLUDES REPLACEMENT OF MANUAL ABORT & MANUAL RELEASE STATIONS; •• INCLUDES LISTED INTERFACE WITH EXISTING PRE-ACTION SOLENOID; , •• A NEW SERVICE DISCONNECT SWITCH SHALL BE INSTALLED & MONITORED BY THE FACP FOR TIMES OF PRE-ACTION SYSTEM MAINTENANCE; VALIDITY OF PERMIT • FIRE ALARM SIGNALING UNE CIRCUIT SHALL BE CLASS A IN NATURE FOR COMPLIANCE WITH APPUCABLE CODES & MANUFACTURER'S INSTRUCTIONS; • COMPLETE FIRE ALARM NOTIFICATION COVERAGE; THE ISSUANCE OF A PERMIT • PROVISION OF NEW FIRE ALARM MONITOR MODULE FOR EXISTING STAND-ALONE AIR-HANDLER DUCT DETECTOR; BASED ON CONSTRUCTION DRAWING: • RELAY INTERFACES WITH EXISTING BUILDING FIRE ALARM SYSTEM FOR OFF-SITE COMMUNICATIONS TO MONITORING STATION; • MONITORED INPUTS FOR INTERFACE WITH EXISTING BUILDING FIRE ALARM SYSTEM. DOCUMENTS AND OTHER UPON COMPLETION OF ACCEPTANCE TESTING WITH LOCAL AUTHORITY HAVING JURISDICTION, THE EXISTING FIRE ALARM SYSTEM SHALL BE DATA SHALL NOT PREVENT - DEMOLISHED. EXISTING SYSTEM IS TO REMAIN FULLY OPERATIONAL UNTIL SUCH TESTING IS COMPLETED & ALL DOCUMENTS ARE APPROVED BY THE CODE OFFICIAL FROM wu_ LOCAL AUTHORITY HAVING JURISDICTION. F1\O . I L-) • REQUIRING THE CORRECTION } OF ERRORS. OSSC 105.4 e, w - J CUSTOMER NAME: McKINSTRY 16790 NE Mayson St. Suite100 Portland, OR 97230 Co ' -��d n Aii TEC - le • ES 1 7678 SW Mohawk St,Tualatin,OR 97062 Phone: 503-228-8522 Fax:503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot he reproduced by any means without the written authorization of Convergint Technologies LLC. UDE MOUNTED INSIDE I 01-01-0140 VEP4B F1RE1 GENERAL NOTES: 01-01--0,41 VEP46 FTRE2 01-01-0142 VEP4B ALERT 01-01-0143 VEP4B FAULT A. ANY & ALL DEVIATIONS FROM THESE PLANS SHALL REQUIRE THE 01-01-0163CR VEP4B RESET APPROVAL OF A CONVERGINT TECHNOLOGIES PROJECT MANAGER OR - - —...- SYSTEM DESIGNER. ! -- FACP11k 15K B MEC LAICAL 03 ROOM IS PROTECTED BY WET SYSTEM SUPPRESSION ' 1: 'J IANI'T' A FACP17 02 I APS I � 4B A C. SOLEFN�O1D IS EXISTING AND LISTED WITH THE SIGH REL I �{ 01-01 D180� -D- - KEYED NOTES: I 01-01-0132 APS TROUBLE A , ii STORAGE r- © - - -6 - - - - -[M]01-9i-0170 , . e - A 75cd DUCT DETECTOR .. 1. EXISTING NON-PERMANENT CABINETRY ALONG WALL TO BE RELOCATED 06 I I FACP1-01 ,1 ar -r 3 TO ACCOMMODATE NEW FIRE ALARM NOTIFICATION DEVICES & CONTROL 1F n r I �___T EQUIPMENT. �A FACP1-01 a r 01-01-01 711 I KH 0?_01174 2. DEMOLISH AFTER COMMISSIONING OF NEW FIRE ALARM SYSTEM. U106 MOUNTED INSIDE _~ ®, Vii, I©01-01-0173 i 1 I 01-01-0174 3. NEW PRE ACTON RELEASING MODULE TO CONNECT TO EXISTING p1-DS-0008 01-01-0133 VEP1A FIRE1 L 01-01-0175 I PRE-ACTION SOLENOID. SEE SUBMITTAL DOCUMENTATION FOR UL LISTING -� 01-01-0134 VEP1A FlRE2 I 01-07 0176 APPROVALS. 01-01-0135 VEP IA ALERTI L... �-J 01-01-0136 VEP IA FAULT r; Tit . - l 01 01-0168 VEP1B FIRE1_ i_ 1_ , , 1 ...--0 01 01--0169 VEP1B`'FIRE2 III] a I I O1-01-0166 VEP1B ALERT I 1U; I RE-ACTION 01-01-0167 VEP 1B I; `- 01=01-01i,P® : 15�A I0 01-01-0164 VEP1A RESET ,-,} O1.. DISCONNECT PTO1-D1-0148 1 VEP1B RESET ,- SWITCH M.81-11,812 01-01-0161 • E i ¢ i- -BRLAK I VEP1A ] !k IGi In brQaI APS TR-016575cd , 04 0AS_OD07 - p1-01-01fiId YAPS /// h FACP1-02r ( 1 I 75cd 15c� A__6. - b S FAD T L:� FA 1-O2 U IT (r) I A FACP1-01 l. -01 FACP c I 1 :�:� x}01-01-0006 L J - . - J 'y !:� u FACP1-03 15K 1 ACP1-03 F1-01-0151 C C 7_4 __._ W 75cd - 01-01-000S +. I i -I C I a I I b xi— ElI ,Scd I I 1 - I '- [ I x . •:=.-AFACPI-01 I 1 _ I I _ __ • I a -- -- - -. 05 FACP L I -I FACPI 02 .. I , - !:) I I j 0}-01-OOD4 i C I I. J ,� i _1 H1 € 1 I , .� -,moi 9 I UIOt MOUNTED INSIDE R - e a L i HR TC - I C�� FACP1 02 01 01 0127 VEPA F]RE1 - L- I z 01-010128 VEP4A FIRE2 - ' - - -- - ',7 11 d 75cd o-A APS TROUBLE 01-01-D13001 Y P A ALERT__ [ 1 III [a I V i 01-01-0144 I _ FACP1 O1 01-01-0162 CRVESDA RESET 914LEA HR TD HR TD �A � 1-_ L -I III I - — U GENE DURNIN fACPI 01 FRCP 01-01 00011 1 'l I i !!. -:17._.-"M— _- =sem Digitally signed by Eugene Ournin w 01-01-0002 I `y 1 DN:C=US, 01-01-0003 m A,C FAHR CPIT 03 I - -' I O'Conv erg n[t1TTechnaleogies�LLC, A III I CN=Eugene Dutnin n L_ 0 A OFFECL a ei 4 07 - 75cd } ( 75cd Date:2079.01.1417:54:2308'00' 01 Ot 0131 L �--. FACP1-03 I i T-ACP1-03 I I WIRE SCHEDULE ~ - - - - _., - -- r- i 12 LEHER TYPE USE 1 I ,, p. 0 I o-C I - �C x A 1 PAIR 18 AWG. TWISTED FPLP DATA LOOP/NETWORK T,I �_ B 2 PAIR 20 AWG. RS 232 11 NI �" rs ERAL ALARM c - - - /] J {,.- •/ C 1 PAIR 14 AWG. TWISTED FPLP FACP CKT/24VDC 01-01 0138 01-01-0146 - E 1 PAIR 18 AWG. TWISTED FPLP AUDIO CKT I 0 CNERAL 7RDUBLf - rm © ►��4 F SEE FAO.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. 4 i I J4 1 I Ot-41 0152 m Q FACP 103 FACP I I III © ' -- r ,-F.'. :i "•- 1 I REVISIONS I L J LE• vs -Li • I FACP:t- 1,,' I REV DESCR€P110N DATE APPROVED �� 03 - --- -- -_ - .••-SPACE 7Dcd I I �_ _ L 1.3 1 1 (Pn �w FACP1-03 j-- �� I -. _ _ - - 1 ') DRAWN BY: Q. LANG ZPROJECT ENGINEER: B. DUFFEL PROJECT MANAGER: G.DURNIN o i ! J I j I`1-' SHOP DRAWING SUBMITTAL DATE: 01/11/2019 � I I CONTRACT TYPE: PLANS 8 SPEC:0 DESIGN BUILD:in CO �A i PROJECT NAME: AT & T NIMBUS FIRST FLOOR FIRE ALARM PLAN 10340 SW Nimbus Ave SCALE:118"=V-U" Tigard, OR 97223 a 0 4' 8 16' SHEET NAME: rn 0 e Lu FIRST FLOOR FIRE 0 ALARM PLAN 5 r 4 DRAWING: w FAI . 1 z :,_m „, i J CUSTOMER NAME: McKINSTRY 16790 NE Mayson St. Suite100 Portland, OR 97230 r CO 1 orvieos nt Ape TEC - • • ES 1 7678 SW Mohawk St,Tualatin,OR 97062 Phone: 503-228-8522 Fax:503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC. TYPICAL -12" CEILING BEAM. rr p I ASPIRE VALIDATION SOFTWARE PIPE l2 E RA L NOTES: DESIGN ASSUMES THAT PIPES WILL BE INSTALLED BELOW CROSS BEAMS. I A. SITE INSPECTIONS INDICATE PIPE MAY BE INSTALLED ABOVE HVAC DUCTWORK & BELOW 12° NORTH SOUTH BEAMS WITHOUT INTERFERENCE SA GRILL SHOWN ON NORTH/ SOUTH PIPE JOGS. ENGINEERED PLANS DOES NOT EXIST ON SITE. B. VALIDATION SOFTWARE INCORPORATES PIPE INSTALLATION JOGS IC I +.,BAPS I / ACCOMMODATE 24° EAST/WEST CEILING JOISTS. 103, r„ I I I I 1II I C. ALL 'ASD-LL' SUSPENDED PIPES ARE TO BE 6'-0° EN LENGTH WITH 43/32",, 43/32' I I HOLES DRILLED IN TO END-CAP PIECES TO THE DIAMETER SHOWN ON PLANS. INSTALLING CONTRACTOR TO PROVIDE SUPPORT STRUCTURE. ,.,r I r I 1 I � 1 LL r_ ���+tcc w I d D. ANY & ALL DEVIATIONS FROM PIPE PLAN MUST BE VERIFIED BY H , iso _ . „�-,, A, 41/8" 41/8' I �I 43/32° 03/32' CONVERCINT TECHNOLOGIES PRIOR TO INSTALLATION. I 43/32 i I 43/32' 03/32" I E. ALL DIMENSIONS SHOWN ON ASPIRE PIPE VALIDATION SOFTWARE I 111 " 1 1 I ��yy I DOCUMENTATION SHALL BE VERIFIED BY INSTALLING CONTRACTOR PRIOR I XAsu 1 I I )i(- I TO PIPE INSTALLATION. S -24" TION JOIST. ASPIRE KEYED NOTES: Asn-LL ASD-LL ASD tll/8" ! i I 143/32' I VALIDATION SOFTWARE nsn }LASD 1 1 j I I ACCOUNTS FOR PIPE TO 41/8" 01/8" i i 1 I I /ACCOUNTS BELOW JOISTS. 1. TEST POINT LOCATION. INTENDED TO BE LONGEST BRANCH END CAP -- — --T----_—r -* -- --I-----1-----1 — (g FROM VESDA DETECTOR PER INLET. C— } i � I _' PRE AClION j ' 1LASD-�E ASD - ASD u ! � I t5 41/8' 43/ 2" 43/32' 03/32193/3Y Tr--�f 4u4 D I 4 32' 3/32" 43/32', � 03/32° j F �•I A"(1°1 BREAK t' 161 8 d'k g I r•,- , I - 04 •VEP1B /° l- 1 ;ir, APS 1 : I .ASaLL .1 - I A� s k..I it I I`1 .1 I I I I 1 m3/32" FRCP I 43/32° 1 143/32' I 43/32' .. 43/32' 03/3+2,° i ' II I I 1 I I� I I • O I D aso-� ASD _L. 1 Aso-i I i�I ' r I 4.—1-4 ____,I.._c 1 I 1 ,. 1 �Ir. ! 1. - I 1 § 1 I I f 1 E � - 150-L4 A50-LL 1 - A59 � ISO-LI. A50 ... �7flIaET -037-31P, 43/32" g 43/32" a/ I 03,.321., 0 32r,., j oOPEN ]F�i0 r II ! I I I 1 43/32" Ei 1 1 >1 I Ei 1 b f i WF I I E -24° CEILING JOIST. ASPIRE I I I ACCOUIDATIONTS FOR SOFTIPE WARE 0 I 43/32' -Ali /32" I I ;3/32' " •- / � 43/3x•` A3/32' cn _-\.. z r. JOG BELOW JOISTS. g E.i I l I I 1 -u p ASD l Asu-LL Asc.::. LS I ps I AM-11 1 I Aso-LL I:82 I £i + iiii bi 914LEA L12 L3/32" a d3/ 2" 43/32' 1143/32° Im3/3�" 43/32' i Cu j r L l =:x I GENE DURNIN 1 o I A A I 1. 1 Digitally signed by Eugene Durnin m - .' 1 i 1 R� Al I--% I,E ;;,:ems DN:C=us, a E.Denatturn cn s E I Ing �" `' C� OConvergnCD lt Technologies LLC, a -24° CEILING JOIST.IASPIRE 1 '� a' � CN=Eugene Dumin / 1:1113°2* i'VITI 3 _-. 13/32" / Date:2019.01.14 17:54:47-08'00' VALIDATION SOFTWARE 1103/32' 03 32" I3 32" a ACCOUNTSJOG BELOW PJO STSIPE TO i }�I a hlineian ! Aso-LL Aso ASD L I ASOc. I 1 w WIRE SCHEDULE r I I 1y}�� LEIILR TYPE USE . � typ=u 1 _ �X `► I A 1 PAIR 18 AWG. TWISTED FPLP DATA LOOP/NETWORK ! x47/64" 47/64" I�� 4T/fi4 ! I J a iL�ff'fsC 1 PAIR 14 AWG. TWISTED FPLP FRCP CKT 24VDC N a --1 I 1 07/641 07/64" F_ B 2 PAIR 20 AWG. RS-232 / IASS i 07/64" I 47/64' w 7 t 147/$4° j I E 1 PAIR 18 AWG. TWISTED FPLP AUDIO GEL ec �` I" m I I SEE FAO.i FOR WIRE SCHEDULE NOTES & GU1DELlNES_ hi 13 I .1 I,I =-„ ..., _ REVISIONS c ai.7 REV DESCRIPTION DATE APPROVED Jar, , , 1 CO Q. I I F 1 ENT �,17..^.__ - t-1,-- SPACE 1 a I . 11 i4 BEM II I I L1 'l r-- - - — GROUND TAN - —co 13 DRAWN BY: 0. LANG o PROJECT ENGINEER: B. DUFFEL FT LT I I PROJECT MANAGER: G. DURNIN _J 1 I 1 FOB NUMBER: 302FNH0401 JI SHOP DRAWING SUBMITTAL DATE: 01/11/2019 fl CONTRACT TYPE: PLANS&SPEC:❑ DESIGN BUILD:■ ® C CID C} PROJECT NAME: AT & T NIMBUS m • FIRST FLOOR VESDA PIPING PLAN 10340 SW Nimbus Ave SCALE:1/8"=1"-0" I Tigard, OR 97223 b I I .1•.. I l ! I i i f i 9 "' 0 4' S' 16' 01 SHEET NAME: IL ti FIRST FLOOR VESDA PIPING PLAN 0 a_ DRAWING: _ „ FAI . 2 z ... >_ ., c ,_, ui J CUSTOMER NAME: McKINSTRY 16790 NE Mayson St. Suite 100 Portland, OR 97230 QQ I rte:►/� tn 4, TEC - • r ES 7678 SW Mohawk St,Tualatin,OR 97062 Phone:503-228-8522 Fax:503-228-8521 This document and the information/depictions contained/shown is the exclusive property of Convergint Technologies LLC and shall be handled as proprietary and confidential information and must be returned upon request.This document cannot be reproduced by any means without the written authorization of Convergint Technologies LLC, KEYED NOTES: 1. NOT USED. 3106 MOUNTED INSIDE LA06 MOUNTED INSIDE 01-01-0127 VEP4A FRE1 41--01-0133 VEP1A FWE1 01-01--0128 VEP4A FIRE21 01-01-0134 VEP1A FIRE2 01-01-0129 VEP4A ALERT 01-01-013501-0169 VEP1AVEP1B ALERTFIRE2 01-01-0130 VEP4A FAULT 01-01-0136 VEP1A FAULT 01-01-0162 CRVESDA RESET 01-01-0168 VEP1B FIRE1 o 00011i-v011--00116395 1 U105 MOUNTED INSIDE 01-01-0166 VEP1B ALERT v — 01-01-0167 VFP13 FAULT N 01-01-0140 54 VEP4B FIRE1 01-01-01 R UFP1A RESET 01-01-0141 VEP4B EIRE2 S, 01--01 0143 VEP4B FAULT 01-01-0161 R VF71B RESET i 01-01-0163 VEP4B RESET C z • Y (5) (4) (2) (2) 1) (1) (7) A C�VEP4B C VEP4A7 APS r C VEPSB— — - ® EQUIPMENT 14 C (5) (2) FACP-03 ca gg� m — b C VEP1A I 15K bE IL- I L� (1) z '�'" 0) I FAD914LEA - FACP-02 L (1)- - L.-.'.- •FACP I b (2) GENE DURNIN m I ANN i 4 i • 120VAC i Digitally signed by Eugene Durnin A,Cl_ . — (BY OTHERS) I j a I _ _ _A {CLASS A RETURN) OPEN QFFlCE O5i FACP-01 O Can er int Technologies C (3) (2) E=gene.dUrnln�conVarglnt.Com, c7 t- �'t'"`- g LLC, L ._.- - - - - - - - - �.-.-.- - -b— - - - - - - _ - _ - � ® � �*.c' CN=Eugene Durnin Date:2019.01.14 17:55:06-09'00' as FIRST FLOOR WIRE SCHEDULE 1 6 Lr LLIILR TYPE USE I 1 A 1 PAIR 16 AWG. TWINIET1 FPLP DATA LOOP/NETWORK I o B 2 PAIR 20 AWG. RS-232 C 1 PAIR 14 AWG. TWISTED FPLP FACP CKT/24VDC w FIRE ALARM RISER DIAGRAM E 1 PAIR 18 AWG.TWISTED FPLP AUDIO CCT oa SCALE:NTS O SEE FA0.1 FOR WIRE SCHEDULE NOTES a. GUIDELINES. -- v' REVISIONS a REV DESCRIPTION DATE APPROVED ITIf m, 0 0 E.a Y o O DRAWN BY: O. LANG PROJECT ENGINEER: B. DUFFEL z a a o PROJECT MANAGER: G. DURNIN JOB NUMBER: 3O2FNHC401 SHOP DRAWING SUBMITTAL DATE: 01/11/2019 CONTRACT TYPE: PLANS a SPEC:D DESIGN BUILD:■ PROJECT NAME: AT & T NIMBUS 10340 SW Nimbus Ave C- Tigard, OR 97223 In 6 SHEET NAME: • FIRE ALARM RISER k 0 0 DIAGRAM DRAWING: L FA2 . 1 r En m L w CUSTOMER NAME: McKINSTRY 16790 NE Mayson St. Suite100 Portland, OR 97230 15.7500 . Co 00,•• ••;;./0 offv/O . nt ar, TEC - • • ES 7678 SW Mohawk St,Tualatin,OR 97062 Phone: 503-228-8522 Fax: 503-228-8521 �� !-� (�'l r� This document and the information/depictions contained/shown (..----- / J1 ,r ) /� is the exclusive property of Convergint Technologies LLC and /j shall be handled as proprietary and confidential information and '��- �� V._--:-_-,.. must be returned upon request.This document cannot be reproduced by any means without the written authorization of UNE I+ I T- Convergint Technologies LLC. 120VAC DEDICATED GROUND 0 ' &&_ I- ' W- l j nr° •'-')l' ''''' I II i� C) CIRCUIT (BY OTHERS) t3EDTRAL I ' I - & - t. � ), .it, -1_....1 Fire Alarm System Battery Calculation Form �C31 _ ,1 .(....,;,,i ID - - c c c ID - .;..:,).01 ,,. 1 I I� System voltage(Vdc):I 24 Project name'AT&T NM BUS F_J}- _I- ±<:,,)_r- Val- _...i G I - _-�..�� :1 Int A LOOP 1 p rvisory M nuurs:1 25 Project nemf�r:1302FNH6401 �� I iO-1000 tiOs °10 Extra Battery Capecity�l 20% Panel Location,I Bectrical Room NE I' ' Power Supply ID IFACP I " ' �B I I CLASS A RETURN AH required-Supervisory:' 9.29 Comment'' ( J I I�Jsiv II�FRFtLA5it - •• -- " +�� , AHrequlred-Alarm l 0.38 I xc �SW 20 ACPQAfR t ,„„,.,.---7------- I -i "S I� d u a ID Total AH required(with%)I 11.60 � [E �JI Battery AH provided:' 12 L a, '.w C I _,t'E°E, t MIME E 0,j i (1.,:cQpAi� - iiCll r!Ltit 4➢t 1F8'' I t ,) - 2, 0 ''H'IA .. 1. , --L i f oil!, slcNaE � ' i, I�� 1 r .. J 14 ,?Hi Line Identification Quantity Supervisorlr mAl Alarm mA Total sup.Illine Total Ala.illine iI -IC } CRiEf. _ r 1 !01000 1 172.000 267.000 172.000 267.000 I I �.-_ (C,_ _- "v _ �-��' ._ . ..� 6 2 Loopi.lnlernal 1 45.000 115.000 45.000 115.000 3 0.000 0.000 i I `✓�� 1.__ ______ j cli�� �+ _laitemE \ �..--_ n 1 4 RLCa6C nLoop 1 45.000 0 94.000 115.000 99.000 115.000 • 5 SA-232 1 13.000 20.000 13.000 20 000 Y>I CT - '1 " - ;' `, - f„/c, I NAC1 CIRCUIT I s sA-aAcr 1 41.000 100.000 41.000 100.000 C)CD I _,„Its €, I 1 7 SGA-REI 1 17.000 415.000 17.000 416000 Ei"1 �- �[I _ i ) NAC2 CIRCUIT 1T FACPoi 1 697.oa0 0.000 as7.000! ) 18 FACP 021958.0000.000968.fl00! �q/- II \ �! 19 FAC -03 1 1703.000 0.000 1703.000 �- - - _ ; , �\ 1`� p C l . _ I -- I O I iJ 20 FACP-04 1 0-000 0.000 0.000 I 9Wm: ` 11.- NAC3 CIRCUIT �_ I 1CEP �_ t i- {_ -,l' I - Fnmr3la:(g Supervisory rrA`Supervisory Hours)r(Alarm rrA`AlairnLanutes)J'6rlra Capacity)-Total A H required U IL fl • �� ilii, 24VOC SIGH-REL 5' 1 {.,1� } ' General Note.FACP current draws are reflected in their'worst case'scenario.Current draws have been rri (11L**icLil [7_Fir.1- �p IT ��� ��� u taken from the UL approved installation vide- I• 11i..--------- ° ^�\\\\\ / PRr 9 r vccua E (t) i^l+�f+)r-1-1t3 C� \' €� I` ,1, 1 I 1Total Supervisory mA:I 387.00j" , '., el a 0 Powero Total Alarm mA: 4591.00 A0 o I0jO supervisory.-: 0 0 Ground Fautt L - - - Trouble i 0 2�.aoao Enabled r I�oAcsSilence VOLTAGE DROP CALCULATIONS FACP in 1 ` I \70Reset Circuit Alarm Resistance! Circuit Voltage Q ® ® Q Length Sup.Current Current Wire Gauge 1000ft Resistance Drop ( ylOSIgnelSilcries Circuit Name (ft) (A) (A) (awg) I (ohms) (ohms) (V) z 'O&3f111 FACP-01 165 0 0.35 14 3.07 1.0131 0.218 FACP-02 145 0 0.405 14 3-07 0-8903 0.229 914LEA z f ' OLentpTea@ l FACP-03 187 0 0.869 14 3.07 1.14818 0.483 z TRANSFORMER w - le J FACP-04 0 0 0 14 3-07 0 0.000 GENE DURNIN co Digitally signed by Eugene Durnin Aux 0 0 16 4.99 0 0.000 m ` POINT•It•POINT CIRCUIT BREAKDOWN DN:CRUS, / I O FACP-01 FACP-02 E�ene.dumin@convergint.00m, N., Deuce Distance to Voltage at Deuce Distance to Voltage at t Ll - K� O.Cohvergint Technologies LEG, `' Number Deuce Device Current Device Number Deuce Deuce Current Deuce CN-Eugene Dumin ._ FACP-01-01 50 0.125 18.99 FACP-02-01 30 0.04 19.03 Date:2019.01.14 1755:24-08'00' • FACP-01-02 40 0.03 18.94FACP-02 02 40 0.115 18.94 ° FACP-01-03 15 0.03. 18.92 FACP-02-03 10 0.125 18.921 a i __._.-__ iIr ii - II Il FACP-01-04 10 0-04 18.91 FACP-02-04 65 0.125 18.871 WIRE SCHEDULE o ,s, 'I 4+ FACP-01-05 35 0.125 18.88 FACP-02-05 0 0 ' LEIIER TYPE USE 0 FACP-01-06 0 0 FACP-02-06 0 0 A 1 PAR 18 AWG. TWISTED FPLP DATA LOOP/NETWORK( FACP-01-07 0 0 FACP-02-07 0 0 (/ � FACP-01-08 0 0 FACP-02-08 0_ 0 5 2 PAR 20 AWG. RS-232 C-4 O ' (' h��f O FACP-01-09 0 0 FACP-02-09 6 0 C 1 PAIR 14 AWG. TW151EU FPLP FAIR CKr 24VDC ��------ I eeaeeeee / w FACP-01-10 0 0 FACP-02-10 0 0' F 1 PAIR 18 AWC. TWISTED FPLP AUDIO CKT re FACP-01-11 0 0 FACP-02-11 0 0 .� I 1 ,,, , -ii .q 1 47 FACP-01-12 0 0 FACP-02-12 0 0 SEE FA0.1 FOR WIRE SCHEDULE NOTES & GUIDELINES. CE I on WIN t) (0 �l t)� FACP-01-14 0 0 FACP-02-14 0 0 aeHour Q 11 .21) A Ric FACP-01-15 6 0 FACP-02-15 0 0 L_) PH2tODIOW II e m 11 v( REVISIONS FACP-01-16 0 0 FACP-02-16 0 0 REV DESCRIPTION DATE APPROVED n_ efts(«iOrR [L Q 3] F cr FACP-01-17 0 0 FACP-02-17 0 0 aa0ouT [I c (0 3] E FACP-01-18 0 0 FACP-02-18 0 0 Q 2 Q 31 0 -Qui. FACP-01-19 0 0 FACP-02-19 0 0 CD 2044 tM Q Q m 1] C FACP-01-20 0 0 FACP-02-20 0 0 Lu :NN1� Q @ 3�,1I arr Han II o_1 A - 0 O o FAC"-03 FACP-04 co TX Device Distance to Voltage at Deuce Distance to Voltage at IDRAWN BY: Q. LANG Number Deuce Deuce Current Deuce Number Deuce Deuce Current Deuce O I PROJECT ENGINEER: B. DUFFEL o I +X4 +�� FACP-0301 20 0.115 18.99 FACP-04-01 0 0 „.� FACP-03-02 20 0.046 18.90 FACP-04-02 0 0 FACP-03-D3 12 0.297 18.85 FACP-04-03 0 0 PROJECT MANAGER: G.DURNIN o FACP 0304 43 0.046 18.74 FACP-04-04 0 4 JOB NUMBER: 302FNH0401 FACP-03-05 17 0.125 18.70 FACP-04-05 0 0 SHOP DRAWING SUBMITTAL DATE: 01/11/2019LL FACP-03-06 42 0.125 18.64 FACP-04-06 0 0 CONTRACT TYPE: PLANS&SPEC:E3 DESIGN BUILD: ■ 4)1 -F 1 / -F ____(:: ::) FACP-03-07 33 0.115 18.62 FACP-04-07 0 0 FACP-03-08 0 0 FACP-04-08 0 0 PROJECT NAME: FACP-0309 0 0 FACP-04-09 0 0 FACP-0310 0 0 FACP-04-10 0 0 FACP-0311 0 Cr FACP-04-11 0 D AT & T NIMBUS BATTERY BATTERY FACP-0312 0 0 FACP-04-12 0 a FACP-03-13 0 0 FACP-04-13 0 a 10340 SW Nimbus Ave SEE CALCULATIONS SEE CALCULATIONS FACP-03-14 0 0 FACP-04-14 0 0 I I FACP-03-15 0 0 FACP-04-15 0 0 Tigard, OR 97223 CA TABLE FOR SIZE TABLE FOR SIZE FACP-03-16 0 0 FACP-04-16 0 0 g ,ii FACP-03-17 0 0 FACP-04-17 0 0 rn FACP-03-18 0 0 FACP-04-18 0 0 FACP-03-19 0 0 FACP-04-19 0 0 I SHEET NAME: v FACP-03-20 0 0 FACP-04-20 0 0 I r I FIRE ALARM CONTROL iii PANEL WIRING DETAIL & FIRE ALARM CONTROL PANEL DETAIL FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS BATTERY CALCULATIONS SCALE:NTS SCALE:NTS DRAWING: _ c, FA3 . 1 Z )- CL Oa l..l in p - , CUSTOMER NAME: TERM DESCRIPTION 1 NOT USED DATA IN FROM SIGNATURE 2 DATA IN/OUT (+) CONTROLLER OR PREVIOUS 3 NOT USED DEVICE McKINSTRY 4 DATA IN (-) (-)(+) 16790 NE Mason St. Suite100 47K EOL .5....-:" 6 REMOTE LED 5 REMOTE LED 11 V 0 O O Portland, OR 97230 417 TYPICAL N.O. --- ' 6 NOT USED .(b INITIATING DEVICE ;I`;i MOUNT IN T�jj 7 / 7 DATA OUT (-) O _ 0 II 3 OCT. BOX , 1 Ill 11 �r11*�� �' �i}' II NC2 0 0 0 0 r�`' C� � E4' NO2 ® CO - , SI4GLE INPUT UODUtE �1 I NC1 ® fl �/� 0 AO o . hiit. I / 0 jNot ® TEC - • • E c7 3 4m 7678 SW Mohawk St,Tualatin,OR 97062 sTANcAo 30.3E Q o O o / -(+) 2pVAC Phone:503-228-8522 Fax:503-228-8521 �� ® )-® SIGAtiSmr r �I DATA IN (-) DATA OUT ( ) H H DATA IN (+)> ! DATA OUT (+) TO NEXT DEVICE This document and the information/depictions eontained/shown DATA IN (--)> 1.- DATA OUT (-) DATA IN (+) F DATA OUT (k) is the exclusive property of Convergint Technologies LLC and FROM SIGNATURE TO NEXT DEVICE FROM SIGNATURE TO NEXT DEVICE shall be handled as proprietary and confidential information and CONTROLLER OR CONTROLLER OR must be returned uponrequest.This document cannot be PREVIOUS DEVICE PREVIOUS DEVICE 120VAC DAMPER I reproduced by any means without the written authorization of CONTROL CIRCUIT Convergint Technologies LLC. CISINGLE INPUT MONITOR MODULE SMOKE & HEAT DETECTOR BASE FSD CIRCUIT SHUTDOWN d RESERVED GENERAL NOTES: SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE T SCALE:NOT TO SCALE I A. WIRING DETAILS ARE TYPICAL. NOT ALL DEVICES SHOWN MAY APPLY TO THIS PROJECT. B. DEVICE T-TAPS TO OE MADE ON OUTBOUND TERM4NALS DATA IN FROM SIGNATURE CONTROLLER OR PREVIOUS ' MANUAL RELEASE KEYED NOTES: DEVICE I. SWITCH I ALARM -� MANUAL ABORT (-)(+) 1. NOT USED. >• DATA OiJT (-) } TO NEXT TEST - DATA OUT (+) DEVICE V \( OCb 47K EOL 47K EOL STATION M- SWITCH FROM SIGNATURE El I I -- DATAAIN - CONTROLLER OR I 0 - 0 II ` TYPICAL N.O. TYPICAL N.O. AUXILIARY DATA IN (+ } PREVIOUS DEVICE I ®llfll r ell p . ®ii Vee INITIATING DEVICE �I® �} CD (D INITIATING DEVICE �I NC2 1 ICD ALV (DI DEVICES - z a a its 3.;.1 �, . + IN . II C2 I! �' Ta3 7e2 s FROM 24VDCFACP fR '�' NO2 LHM �f SIGNATURE - .O C} O II 1196441.9•14,ll � I I I D 1 I NC1 e I LOOP + > ['-7 + x QUAL INPUT NOODLE G?:�:1 GD III ® i 1 C l 0 1 013•f- _, nIT [!7 1 smA-cTz :ii,pl N01 o SIGA-REL © A o ° 0 II TC D . . JE 3 2 1 ..„ , �' 24v DC �+ « -) ® 0 O 0 (-)FROM FACP '- 2 3 4 '- + 3 + ((��}} /� (j� r r —(+)PANEL/PDWER „� u r L308,13 ` ) () `4) $I (-)(+) SUPPLY 1 I �'��a��. I I � e o a e j TO NEXT DEVICE DATA IN (+)> I ► DATA OUT (+) 47K DATA IN (-) -DATA OUT (-) ZONE XXXX FROM SIGNATURE TO NEXT DEVICE MAGNETIC PRE-ACTION CONTROLLER OR DOOR SOLENOID PREVIOUS DEVICE HOLDERS RELA-EOL I `.i.' 0 DUAL INPUT MONITOR MODULE DUCT SMOKE DETECTOR DOOR HOLDER RELEASE 47K EOE I_ I 3 1 6 8 SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE j:i 2 N.c. i RELA-SRV--1 cptytz -•;c- _0 _ MOUNT IN 4" _� SQUARE BOX a zO , O I J ® � ® ® ® ® (-meQ 0 � [ 914LEA ° 0 GENE DURNIN w z " i z _ 5 I iiIiI il] - FACTORY CONNECTIONS 1-�_ 7 Digitally signed by Eugene Dumin DN.C.1.18.m =1 € li DO NOT ALTER g 7 , 0 / E-gene,duTnin @canvergint.Gom,a o o 0 0 0'� I II II ' , 5 O 7,--_ e[[ ,'`'� CO=NCugvee int TechnaogiesLLC LLC.PULL STATION a —1 sIGA-ago co SINGLE INPUT MODULE Date:2019.01.141]:55:¢]-08'00' ® © FIR SIGA-CT1 Li; 4 3 2 1 FROM BPS OR = ► TO NEXT DEVICE p 0 4 3 2 , 0 .,®®®®(i WIRE SCHEDULE o O eeee OIT -- PREVIOUS DEVICE = ►OR EOL CI © Ili LENER TYPE USE O C O 0321 A 1 PAIR 18 AWG. TWISTED FRP DATA LOOP/NETWORK 41 \,3 0 CI i_ B 2 PAR 20 AWG. RS-232 FRP AUDIO Da O C PAR 14 AWG. TWSTED FPLP FACP CKf/24VDC E 1 PAR 18 AWG. TWISTED F LL C7 o ., SEE FA0.1 FOR WERE SCHEDULE NOTES & GUIDELINES. DATA IN (+) - �- ow- DATA OUT (+) REVISIONS ii DATA IN (+) C - s DATA OUT (+) DATA IN (+)= CUSTOMER NAME: I CEILING SLAB I. :, '. • :-.7.•......-4 '.:. ` - . , . _ - j NOTE: McKINSTRY / 1. A BENCHMARK TEST POINT SHALL BE PROVIDED AT THE FURTHEST 16790 NE Mayson St. Suitel 00 / EN) OF EACH PIPE RUN, OPPOSITE END OF THE ASSD APPARATUS. Portland, OR 97230 2. PROVISIONS SHALL BE MADE SO THAT TEST POINT CAN BE ../ LOCATED WITHIN 6FT (1.82M) ABOVE FINISHED FLOOR. / 3. THE TEST POINT SHALL BE CONSTRUCTED USING A NORMALLY / BENCHMARK TEST •=• CLOSED INDUSTRIAL QUICK CONNECT FITTING PROVIDED BY POINT LABEL MANUFACTURER HAVING AN ORIFICE OF NOMINAL 1/8 INCH / (3.2MM) WHEN OPEN TO FACILITATE BENCHMARK PERFORMANCE r VERIFICATION AS INDICATED IN THIS SPECIFICATION AND ON THE a._,. / S DRAWINGS. Illi CO ' •-n 4. REMOTE TEST POINT IS INTENDED TO BENCHMARK SYSTEM �/� t' / _ PERFORMANCE AT TIME OF INITIAL COMMISSIONING AND DURING Ale ° PROVIDE BENCHMARK TEST POINT / ROUTINE TEST AND INSPECTION. THE TEST POINT SHALL BF AT THE END OF EACH PIPE / LABELED DOCUMENTING BENCHMARK SYSTEM PERFORMANCE AT CE [� RUN 6FT (1.82m) ABOVE / COUPLER TIME OF COMMISSIONING USING MANUFACTURER SUPPLIED LABELS TE I I �] FINISHED FLOOR. / S ,■1 INTENDED FOR THIS PURPOSE. BENCHMARK LABELS SHALL BE DISCONNECTT PLACED JUST ABOVE TEST POINTS AND BE POSITIONED SO THAT 1 / INDUSTRIAL CLUCK C THEY ARE VISIBLE WITHOUT OBSTRUCTION. 7678 SW Mohawk St,Tualatin,OR 97062 ! I �_ Phone: 503-228-8522 Fax:503-228-8521 VESDA FIRE1 VESDA ALERT VESDA FIRE1 VESDA ALERT VESDA RESET VESDA RESET j/ • d47K t47K 47K f 47K / N 1 This document and the information/depictions contained/shown VESDA EIRE2 VESDA FAULT /ESDA FIRE2 VESDA FAULT T / is the exclusive property of Convergint Technologies LLC and t47K 47K —147K J47K / shall be handled as proprietary and confidential information and FLOOR SLAB - -, 1 /. -4 must he returned upon request.This document cannot be 1 2 3 1 2 '' 4 1 2 4 1 2 3 4 1 2 3 4 1 2 3 4 T reproduced by any means without the written authorization of U 10 6 Convergint Technologies LLC. TB1 411 Q)O Ili i_ ail , TB2 Emig TB3 Eng TB4 �N�II,QI} TB5 Id�10, TB6 ®� — - ®� ----- !V 0) TYPICAL BENCHMARK TEST POINT MOUNTING DETAIL GENERAL NOTES: TB 14 SCALE:NOT TO SCALE DATA IN O r-- d O O A pi4 A. NOT USED. (-) 1(+) TB7 O Ili Ii a 0 1i Q I o 1I 0 3 KEYED NOTES: 1 lea 4 ` I ���__"_� BATTERY SIZING CALCULATIONS VESDA POWER SUPPLY 13 3 I 1. NOT USED. ID 2 z z z z z z z CO CO o_ CO UNMONITORED GPI [eD7 1 g g g U T Panel Name: APS(VEP1A&VEP18) B15 TERMINAL SET '0' (-F) (-) I a_o a s I a a s a I 24VDC INPUT w V w w w w w 41 1 L�1 w w w ; 4 Requirement for standby current:I 24 hrs. Design SupenAson Current= 20.93 amp-h r DATA CUT n' to , , ,, 7.._r) ._. �� S N r-I S 7 r 2 IN FROM VESDA {+) o o Requirement for alarm current:) 5 min. Design Alarm Current= _0.09 amp-hr POWER SUPPLY (APS). o ( E w- Spare Battery Capacity:I 0 % Additional Capacity Current= 0.00 amp-hr (0 ____5R_ -...- (®i_ �_ �_ �_ �®� III 1 MIN.BATTERY SIZE REQ'D= 21.02 amp-hr RELAY IN FROM BATTERY SIZE PROVIDED= 24 AH ShGA-MCR PANEL EQUIPMENT Standby Alarm TOTAL TOTAL (ma) (ma) (ma) (ma) C> NO NC • FIRE 2 Quantity Device Current Current Standby Current Alarm Current a c G M c )TO SIGA-MCT2 2 VESDA VEP-A00-1P 366 400 732 800 1 VPS(APS6A) 140 270 140 270 a He s, rq 0 I 0 0 0-1 No Nc • 1 FIRE 1 I PANEL TOTALS 872 1070 0-1 c H L c JI TO SIGA-MCT2 Standby Alarm o acro _ 401 NC C 1 GRAND TOTALS(field&panel) I 872 I 1070 I la- URGENT FAULT / • NO Nc Form uta: [(A+B)x C]+[(D+E)x F]x G=Minimum Amp Hour Battery Capacity APS10A BOOSTER POWER SUPPLY 0 (Q) JP3 TB1 TO SIGA-MCT2 , e K II o Nc A313 NO 0 Where: A=internal panel standby current{arrps} NOTA: POLARITY SHOWN NIA�C 1 / + IS 1 24VDC TO VESDA ALERT / •• NOg B=External device standby current{a{aims}, V I N ALARM YY AUX1 TO SIGA-MCT2 c J C=Duration panel must reran operatonal{hours}. D=Internal alarm current{appsy O NC.* E.External device alarm current{apps}. NAC2/ + F=Duration panel post remain in alarm after standby period ends(hours} 24VDC TO VESDA G=Spare battery capacity(percentage}. - DO NOT CUT AUX2 - ® DETECTOR JP4 FOR 17AH BATTERIES TYPICAL VESDA VEP INTERNAL WIRING (1). WORST CASE APS BATTERY CALCULATIONS - +NAC3/ ■15K SCALE:NOT TO SCALE SCALE:NOT TO SCALE AUX3 - 0 ;,1 NAC4/ AU X4 _ , I '15K L 200mA m + 914LEA ci Cant. AUX ' — ® GENE DURNIN LU Digitally signed by Eugene Dumin cn + IN LEGEND E= Ce.du 2 SENSE 1 - COM -t - - E=C n yergi t Technologies LL , O u T - A t ' " t "� k � Date:2019.011 141Of 17:56:03-08'00' LOW VELOCITY {HIGH STATIC PRESSURE) AREA i i' 1 �"` O=-Eu ene Technologies LLC, �� o B � a T � � HIGH VELOCITY (LOW STATIC PRESSURE) AREA t — f MODE: C0� + IN B µ� ( 01111,1_9 �, 4,4ye„Te i I WIRE SCHEDULE - SENSE 2 LETTER TYPE USE l AIR STREAMLINES (AIR FLOW DIRECTION) •4 •• 3 •• NACs: SENSE FOLLOW coM CI =j A 1 PAIR 18 AWG. TWISTED FPLP DATA LOOP/NETWORK A SYNC: O N OUT ® i I ti B 2 PAIR 20 AWG. RS-232 - D SAMPLING POINT (SEE NOTE 1.) C t PAIR 14 AWG.TWISTED FPLP FACP CKr/24VDC w NF0 47K E PAIR 18 AWG.TWISTED FPLP AUDIO cKr PWR TO BATT I�3L - oOlVl I r NOTE: SFE FACIA FOR WIRE SCHEDULE NOTES & GUIDELINES. '� N G + - - NC ill 1. AIRPLING SAMPLING PIPE DISTRIBUTION NETWORKSHALL BE DRILLED TLY ANDNTOBE THE TOP VIEW REVISIONS OA a — B 2C ORIENTED 30-45' DOWNWARD TOWARDS THE INCOMING V �� -—` I P300 0P40 f �i ;���� �� � 1 8 7 AIRFLOW. REV DESCRIPTION DATE APPROVED cnLU 1 2 3 1 5 6 7 8 1 2 3 4 5 6 7 8 L° / sW1 SW2 1 JP2 0 0 • im LLISINGE iF. L3f MODULE REFEROSWITCH INSTALLATION GUIDE 51� ' SAMPLING POINT ORIENTATION DETAIL o FOR ASSIGNMENT. co SCALE:NOT TO SCALE I DRAWN BY: Q. LANG -11 HOT © _ PROJECT ENGINEER B. DUFFEL ,- 120VAC FEED OTHERS NEt1TRAL 4 3 2 1 VI A.- C, I PROJECT MANAGER: G.DURNIN -,k Li GROUND cl - JOB NUMBER: 302FNH0401 J SHOP DRAWING SUBMITTAL DATE: 01/11/2019 --- • ® CONTRACT TYPE: PLANS& SPEC:0 DESIGN BUILD: DATA IN (+) a DATA OUT (+) ELECTRICAL PROJECT NAME: DATA IN (-) a DATA OUT (-) CONDUITS (2x) FROM SIGNATURE TO NEXT DEVICE CONTROLLER OR o AT & T NIMBUS PREVIOUS DEVICE EXHAUST PIPE AIR ADAPTOT GLUE RS TO PIPE10340 SW Nimbus Ave RECOMMENDATION. _� OF DETECTOR. HONT V EW Tigard, OR 97223 EL �, + + /% �\ SHEET NAME: SEE CALCULATIO\ S— E-T SEE CALCULATION SHEET VESDA DETECTOR VESDA VESDA WIRING, MOUNTING & FOR BATTERY SIZE FOR BATERY SIZE 1-4 POWER SUPPLY DETAILS —$ 4i-.:11 EL 5 0�� ) ! NOTES: � -,� % j I. INSTALLING CONTRACTOR TO DETERMINE METHOD ' `� OF ANCHORING. 2. VACUUM CLEAN ALL SAMPUNG PIPES AFTER INSTALLATION BUT PRIOR TO COMMISSIONING. T} - 3. DRAWING: BOTTOM V EW LU FA3 a4 VPS (APS10A) POWER SUPPLY WIRING (TYPICAL) TYPICAL VESDA VEP MOUNTING DETAIL TYPICAL VESDA VEP SCHEMATIC GISCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE IY fit rn