Loading...
Plans (85) E LC2019-00136 GENERAL NOTES ELECTRICAL SYMBOL LIST (NOT ALL SYMBOLS SHOWN APPLY TO THIS PROJECT) OFFICE copy 1. BEFORE SUBMITTING BID, THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY 24. FURNISH AND INSTALL ALL TELEPHONE CONDUITS AS SHOWN ON DRAWINGS. BEFORE 3/4"C-2#12 HI 3/4"C-3#12. Jo I 2'X4' FLUORESCENT LIGHT FIXTURE, RECESSED IN CEILING. CONNECTIONS INCLUDING ACQUAINT HIMSELF WITH THE JOB CONDITION AND VERIFY SERVICE ALL SUBMITTING. NECESSARY PULL BOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, SWITCH GEAR, THE BID,VERIFY TELEPHONE LAYOUT WITH THE TELEPHONE COMPANY AND INCLUDE IN THE BID ANY MI 314"C-4#12 NI 314"C-5#10. IN I 2'X4' EMERGENCY FLUORESCENT OR LED LIGHT FIXTURE, RECESSED IN CEILING. METERING, CABLE CHARGES, ETC., WHETHER SHOWN ON DRAWINGS OR NOT, BUT REQUIRED BY ADDITIONAL WORK OR CONDUITS AS DIRECTED BY THE TELEPHONE COMPANY. 0 2X2' FLUORESCENT OR LED LIGHT FIXTURE, RECESSED IN CEILING, SERVING UTILITY COMPANY TO MAKE A COMPLETE AND OPERABLE ELECTRICAL SERVICE WITHOUT -Ht-III III 1'C-6#10 VIII IH1 C-7#10 ADDITIONAL COST TO OWNER, 25. FURNISH AND INSTALL PULL CORD IN ALL EMPTY CONDUITS CONTINUOUS AND WITHOUT SPLICES, WIRE SIZE OTHER THAN #12 OR #10 IS NOTED ON EACH CONDUIT RUN WITH SIZE OF Q 2'X2' EMERGENCY FLUORESCENT OR LED LIGHT FIXTURE, RECESSED IN PROJECT 12" OUT OF EACH END OF CONDUIT. CONDUIT (e.g.' 3/4"C-3#8) INCLUDE A GREEN GROUND CONDUCTOR IN EACH CEILING. 2. REQUIREMENTS OF THE GENERAL DIVISION APPLY TO WORK OF THIS SECTION, CONDUIT. (GREEN GROUND CONDUCTOR NOT SHOWN), Q LIGHT FIXTURE WALL MOUNTED. 85.0 26. UNLESS WRITTEN PERMISSION IS GRANTED BY THE ARCHITECT, NO MATERIAL SHALL BE MOUNTED 3, ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LAWS, RULES AND REGULATIONS OF ON THE EXTERIOR WALLS OR PARAPET TOP OF THE BUILDING AND THAT ALL CONDUIT RUNS IN THE 0 TELEVISION OUTLET, +8'-0"OR AS NOTED. Q LIGHT FIXTURE, RECESSED IN CEILING. ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION IN CASE OF CONFLICT BUILDING SHALL BE RUN CONCEALED. BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. 1114.-+ TELEPHONE OUTLET, +18" OR AS NOTED. 0 LIGHT FIXTURE, SURFACE MOUNTED ON CEILING. 27.VERIFY THE EXACT LOCATIONS OF ALL MOTORS, WITH THE HEATING, VENTILATING AND • EMERGENCY LIGHT FIXTURE RECESSED IN CEILING. 4. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REFRIGERATION CONTRACTORS. MAKE ALL CONNECTIONS AND PROVIDE COMPLETE WIRING TO ALL D--'' COMBINATION VOICE/DATA OUTLET WITH NUMBER OF VOICE AND DATA JACKS AS 85°C REQUIRED INSPECTIONS FOR THE EXECUTION OF THE WORK UNDER THIS CONTRACT. HE SHALL MOTORS AND TO ALL LINE AND LOW VOLTAGE CONTROLS, ALL RELAYS, STARTERS, TRANSFORMERS NOTED, +18"OR AS NOTED. Q LIGHT TRACK SURFACE MOUNTED ON CEILING. V a kery Cafe FURNISH ALL INSTRUMENTS AND PERFORM ALL TESTS REQUIRED BY THE AUTHORITIES HAVING FOR THE HEATING, VENTILATING AND REFRIGERATION SYSTEM SHALL BE FURNISHED AND INSTALLED LA NEW PANELBOARD DESIGNATION. JURISDICTION. HE SHALL ALSO CORRECT ALL FAILURES AND REPLACE ANY DAMAGED PORTIONS OF BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED ON PLAN. D0 LIGHT FIXTURE MOUNTED ON LIGHT TRACK THE WORK RESULTING FROM THESE TESTS. THE COST OF THE FOREGOING ITEMS SHALL BE PAID BY 12 REFERENCE NOTE FOR ITEM ON DRAWING. THE CONTRACTOR. 28. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT CEILING BEING FURNISHED BEFORE ® INTERNALLY ILLUMINATED SINGLE FACE EXIT SIGN, SURFACE MOUNTED ON CEILING 9753 S V 1l Washington Sq Rd ORDERING FIXTURES NOTED EITHER AT THE JOB SITE OR WITH THE ARCHITECT AND SHALL PROVIDE INDICATES: A = FIXTURE TYPE; 60 WATTAGE PER FIXTURE. ALSO NUMBER ADJACENT WITH ARROWS AS INDICATED. Suite 042 5. THIS CONTRACTOR SHALL COORDINATE THIS WORK TO OTHER CONTRACTORS FURNISHING LABOR, THE NECESSARY HARDWARE FOR COMPLETE INSTALLATION. A TO FIXTURE = CIRCUIT NUMBER, AND LOWER CASE LETTER = CONTROLLING 4► EXIT SIGN SURFACE MOUNTED ON CEILING WITH EMERGENCY LIGHT, SINGLE FACE MATERIALS AND ALL WORK SO THAT THE WORK AS A WHOLE BE EXECUTED AND COMPLETED 60 SWITCH. SEE DRAWINGS OR SPECIFICATIONS, SECTION 16500 FOR LIGHT FIXTURE EXIT SIGN WITH EMERGENCY BATTERY PACK 90 MINUTE. Tigard, OR 97223 WITHOUT CONFLICT OR DELAY. 29, EXPOSED FLEXIBLE CONDUITS INSTALLED IN KITCHEN, FOOD PREPARATION, DISHWASHING, BAR DESCRIPTION AND WAITRESS STATION SHALL BE OF THE WATER TIGHT TYPE. $ TWO-WAY OCCUPANCY LIGHT SENSOR, SURFACE MOUNTED ON CEILING NOTE: 6. ALL MATERIAL FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW, FREE FROM ALL WHERE TOGGLE SWITCH AND OCCUPANCY SENSOR ARE BOTH SHOWN IN THE SAME 4110 DEFECTS AND SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE 30. UPON AWARD OF CONTRACT, THE ELECTRICAL CONTRACTOR SHALL IMMEDIATELY ORDER ALL ROOM, THE TOGGLE SWITCH SHALL BE WIRED AHEAD OF THE OCCUPANCY SENSOR • OF THE WORK, SHOULD ANY TROUBLE DEVELOP DURING THIS PERIOD DUE TO DEFECTIVE MATERIAL SWITCHGEAR, PANEL BOARDS, TRANSFORMERS, LIGHTING FIXTURES AND ANY OTHER ITEMS OR FAULTY WORKMANSHIP. THIS CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIALS AND REQUIRING LONG DELIVERY TIME. THE ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE ARCHITECT SWITCH POWER PACK, 1725 Westlake avenue n LABOR TO CORRECT THE TROUBLE WITHOUT ANY COST TO THE OWNER. ANY DEFECTIVE MATERIAL OR WITHIN TEN (10) DAYS AFTER AWARD OF CONTRACT A COPY OF THE PURCHASE ORDER OF THE ABOVE D WALL DIMMER SWITCH, suite RECEIVED +46". seattle, Washington 98109 INFERIOR WORKMANSHIP NOTICED AT THE TIME OF OWNER. LAMPS INSTALLATION SHALL BE MENTIONED ITEMS TOGETHER WITH A CONFIRMATION LETTER FROM THE SUPPLY HOUSE FOR A FEB 2 5 2019 CORRECTED IMMEDIATELY TO THE SATISFACTION OF THE SHALL BE GUARANTEED FOR A PERIOD OF SPECIFIC DELIVERY DATE U}'' TOGGLE SWITCH, +46". SUFFIXES ON SWITCH SYMBOLS SHALL INDICATE THE 206.838.5485 p MECHANICAL COORDINATION NOTES 206.713.4076 m CIT`r OF 7IGARD ONE (1) MONTH FROM DATE OF ACCEPTANCE OF THE WORK. FOLLOWING: NO SUFFIX = SINGLE POLE, 2 = 2 POLE, 3 = 3 WAY, 4 = 4 WAY, M = 206.464.0700 f BUILDING DIVISION 31. SITE SHALL BE LEFT BROOM CLEAN AFTER COMPLETION OF WORK. MOMENTARY CONTACT, LV = LOW VOLTAGE LIGHTING CONTROL.. K = LOCK TYPE 7, DRAWING IS DIAGRAMMATIC AND INDICATES THE LOCATION OF OUTLETS AND EQUIPMENT, THE 1. PROVIDE CONDUIT ONLY FROM MECHANICAL UNITS TO RESPECTIVE CONTROL DEVICES (T-STAT., SWITCH. P = PILOT LIGHT. ksmith@smithco.org CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING AND THOUGH NOT NECESSARILY INDICATING THE 32. ELECTRICAL CONTRACTOR SHALL COMPLETE FIRE ALARM SYSTEM PER CITY CODE REQUIREMENTS, BY-PASS TIMER, ENERGY MANAGEMENT SYSTEM, ETC). COORDINATE LOCATIONS AND REQUIREMENTS http://www.smithco.org/ ACTUAL ROUTES OF THE CONDUITS, THE DRAWING SHALL BE FOLLOWED AS CLOSELY AS PROPER WITH MECHANICAL CONTRACTOR/DRAWINGS, AND COMPLY. Q PHOTODIODE/PHOTOCELL FLUSH IN CEILING FOR DAYLIGHT HARVESTING. COORDINATION WITH THE WORK OF THEIR TRADES AND SPACES AVAILABLE WILL PERMIT. 33. THE ELECTRICAL DRAWINGS, CONDUIT RUNS,WIRING AND ELECTRICAL INFORMATION ARE Consultant DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF 2. REFER TO MECHANICAL DRAWINGS/CONTRACTOR FOR CONTROLS AND OTHER WORK REQUIRED BUT gg DUPLEX RECEPTACLE FLUSH IN CEILING. 'r 8. REFER TO ARCHITECTURAL AND MECHANICAL DRAWING FOR LIMITATIONS OF THE BUILDING EQUIPMENT OR OUTLETS NOT SHOWN HERE, AND COMPLY. E.C. IS ALSO TO PROVIDE CONDUITS REQUIRED FOR LOW-VOLTAGE GROUND FAULT INTERRUPTING DUPLEX RECEPTACLE, +18"OR AS NOTED. A. STRUCTURE AND EXACT LOCATIONS OF EQUIPMENT. CONTROL WIRING (BY OTHERS). � 1 0 ' 34, REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL DOUBLE DUPLEX RECEPTACLE, +18"OR AS NOTED. 0 1:. 9. RECEPTACLES SHALL BE SPECIFICATION GRADE ARROW HART, BRYANT, LEVITON, HUBBELL, LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENTS, 3. FUSES FOR MECHANICAL EQUIPMENT ARE TO BE CLASS "IRK-1", 'BUSSTYPE"LPN-RK" (208V), OR "LPS-RK" GENERAL ELECTRIC OR SIERRA. COLOR SHALL BE SPECIFIED BY ARCHITECT. (480V,) "LOW-PEAK". EQUIPMENT NAMEPLATE RATING SUPERCEDES DESIGN VALUES. DUPLEX RECEPTACLE, +18"OR AS NOTED. 35. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY TYPES OF CEILING SYSTEM AND TO 10. TOGGLE SWITCHES SHALL BE SPECIFICATION GRADE, T-RATED, AND WITH SAME MANUFACTURER FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED 4. ALL MECHANICAL AND EQUIPMENT AND DISCONNECT SWITCHES TO BE MARKED. SPECIAL POWER RECEPTACLE, SINGLE PHASE. SEE DRAWINGS FOR SIZE AND AS RECEPTACLES. COLOR SHALL BE SPECIFIED BY ARCHITECT. CEILINGS. FIXTURES SHALL BE COMPLETED WITH NECESSARY MOUNTING HARDWARE AND DESCRIPTION. 4'4,4LP Mnisri '' ''r nsr and ACCESSORIES FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE LABELED FOR USE IN 5, ALL FLEX CONDUIT SHALL CARRY A COPPER BONDING WIRE, SIZED PER NEC TABLE 250-122, SPECIAL POWER RECEPTACLE, THREE PHASE, SEE DRAWINGS FOR SIZE AND Design Services Inc. 11. WALL PLATES AND SWITCHES SHALL BE SPECIFIED ARCHITECT, AND BRUSH FINISH STAINLESS SUCH LOCATIONS. DESCRIPTION. ADR: 3119 Central Parkway, Dublin CA. 94568 STEEL FOR KITCHEN AND FOOD PREPARATION AREA. 6, ALL ROOF MOUNTED AND EXTERIOR EQUIPMENT SHALL BE RATED WEATHERPROOF (NEMA 3R). TEL: 510-788-6029 CEL: 510-468-0613 36. ALL RECESSED LIGHTING FIXTURES, PANELBOARDS, SWITCHES, ETC., MOUNTED IN FIRE RATED SPECIAL POWER RECEPTACLE, SINGLE PHASE. SEE DRAWINGS FOR SIZE AND FAX: 510-788-6039 12, CONDUCTORS SHALL BE 98%%%CONDUCTIVITY COPPER RATED AT 600 VOLTS, INSULATION SHALL STRUCTURES SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE 7, CONTRACTOR IS TO PROVIDE ADEQUATE SUPPORT FOR ROOF-MOUNTED EQUIPMENT. DESCRIPTION. Consultant Registration Architect Registration BE TYPE"THW", "THWN"OR "THHN" OR AS NOTED. (TEMPERATURE RATING SHALL BE 75° C). RATING AS THE STRUCTURE. 8. NO CONDUIT IS TO RUN ON ROOF FOR MORE THAN 4'-0", ALL OTHER CONDUIT IS TO RUN BELOW ROOF elmo SPECIAL POWER RECEPTACLE, THREE PHASE. SEE DRAWINGS FOR SIZE AND CITY OF TIGARD 13. ALL WIRING SHALL BE INSTALLED IN AN APPROVED RACEWAY SYSTEM. 37. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING AND STUB THRU NEAR EQUIPMENT. VERIFY LOCATIONS OF ALL STUB-UPS WITH MECHANICAL DESCRIPTION. REVIEWED FOR CO E COMPLIANCE EQUIPMENT SHALL BE IN ACCORDANCE WITH DIVISION 15 AND ASSOCIATED DRAWINGS. CONTRACTOR DRAWINGS/CONTRACTOR PRIOR TO ROUGH-IN, AND COMPLY. ALL ELECTRICAL PENETRATIONS THRUEl JUNCTION BOX, MOUNTED ABOVE ACCESSIBLE CEILING. Approved: [4.4 �lfe`� 14. WHENEVER ANY ELECTRICAL WORK PIERCE ANY WATERPROOFING, IT SHALL BE INSTALLED IN A OBTAIN THE REQUIRED MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE ALL EQUIPMENTS, ROOF SHALL BE FLASHED. OTC: ( l WATERPROOF MANNER USING WATERPROOF EQUIPMENT. RACEWAYS, WIRING, ETC., AS INDICATED THEREON AS PROVIDED UNDER THE ELECTRICAL WORK. 0 JUNCTION BOX, FLUSH IN WALL, +18" ORAS NOTED. Pcrrnit #: �C.C o/ ,- evsy 3 G Address: S /41...s 4 4- 15. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHTING FIXTURES AS 38. DO ALL DRILLING, CUTTING, CHANNELING AS REQUIRE TO ELECTRICAL WORK AND INDICATED OR Q JUNCTION BOX, CEILING MOUNTED. Suite #: 41" �e INDICATED ON FIXTURE SCHEDULE. FIXTURES SHALL BE COMPLETE WITH ALL GLASSWARE, FITTERS, HEREIN SPECIFIED. ALL HOLES, CURBS, ETC., IN FLOORS, CEILINGS AND WALLS SHALL BE PATCHED ABBREVIATIONS B : RY T N INDICATED OTHERWISE. PAINT ALL EXPOSED ELECTRICAL RACEWAYS CABINETS Q MANUAL MOTOR STARTER WITH THERMAL OVERLOADS, Y Date: .3/�y,. �f CANOPIES, SOCKETS, REFLECTORS, BALLASTS, WIRING, HANGERS AND ACCESSORIES NECESSARY O UNLESS 0 S � � U.G. UNDERGROUND MAKE A COMPLETE INSTALLATION. ALL FLUORESCENT BALLASTS AND LAMPS SHALL BE CALIFORNIA ENCLOSURES AND FITTING TO MATCH IN COLOR ADJACENT SURFACES IN FINISHED AREAS. C,O. CONDUIT ONLY WITH PULL WIRE 0 BY-PASS LIGHTING TIMER, +46". ENERGY COMMISSION (CEC) CERTIFIED ELECTRONIC TYPE, W,P. WEATHER PROOF 39. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC., TO MAINTAIN THE ® MAGNETIC MOTOR STARTER WITH OVERLOADS. 16, ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LAMPS. (USE ENERGY SAVING TUBE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENTS PENETRATING +45" HEIGHT FROM FINISH FLOOR TO CENTERLINE OF OUTLET Issues and Revisions FOR FLUORESCENT LIGHTS OR AS SPECIFIED ON DRAWING). INTO FIRE RATED ENVELOPS, SPACES ETC. V.L. VERIFY EXACT LOCATION 0 MOTOR RATED FUSIBLE DISCONNECT SWITCH (EXO), 30A MINIMUM, SIZE AND NUMBER No. Date Issues By Check N.I.C. NOT IN CONTRACT OF POLES AND FUSES SIZED AS REQUIRED 1 02.07.19 PERMIT SET KLS 17. REMOVE ALL DIRT, OIL OR GREASE FROM EQUIPMENT AND CLEAN AND POLISH LIGHTING FIXTURES, 40. EMERGENCY LIGHTING SHALL BE PROVIDED PER C.B.C. AND SHALL BE DESIGN TO PROVIDE U.O.N. UNLESS OTHERWISE NOTED I' GLASSWARE AND TRIM. MINIMUM REQUIRED FOOTCANDLES AND LUMENS. PROVIDE ADDITIONAL EMERGENCY ILLUMINATION FLUSH MOUNTED PANELBOARD, +6-6"TO TOP, AS REQUIRED BY INSPECTION AUTHORITIES HAVING JURISDICTIONS, A.F.F. ABOVE FINISH FLOOR 18. FURNISH AND INSTALL HEAVY DUTY DISCONNECT SWITCHES AS INDICATED ON PLAN OR AS G.F.I. GROUND FAULT CURRENT INTERRUPTER 0 FLUSH MOUNTED CABINET OR EQUIPMENT AS NOTED, +6-6"TO TOP. REQUIRED BY CODE FOR ALL MOTORS OR ELECTRICAL EQUIPMENT. 41. BRANCH CONTROL CIRCUITING AND WIRE COUNT MAY NOT BE INDICATED ON THESE PLANS, I SURFACE MOUNTED PANELBOARD, +6'-6"TO TOP. CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH 19, WHEN APPLICABLE MOTOR CONTROL CENTER SHALL BE PLUG IN TYPE EQUAL TO WESTINGHOUSE PLAN NOTES AND AS PERMITTED BY AUTHORITY, CONTRACTOR SHALL SUBMIT AS-BUILT DRAWINGS AS [ SURFACE MOUNTED CABINET OR EQUIPMENT AS NOTED, +6'-6"TO TOP. TYPE"W", NEMA CLASS II, TYPE"B"WIRING, WITH CONTROL VOLTAGE AS INDICATED IN AIR A PART OF RECORD DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING JURISDICTION (AHJ). SHEET INDEX CONDITIONING SECTION, MOTOR CONTROL CENTER SHALL BE EQUIPPED WITH CIRCUIT BREAKERS, I I 3/4"THICK PLYWOOD TERMINAL BOARD WITH SPECIAL FIRE RETARDANT TREATMENT STARTERS, AND/OR CONTRACTORS, H.O.A. SWITCHES RELAYS AND TIME CLOCK AS INDICATED IN 42. ELECTRICAL INSTALLATION SHALL COMPLY WITH NATIONAL ELECTRICAL CODE ADAPTED BY THE E-0.1 SYMBOLS LIST, PROJECT NOTES AND SHEET INDEX. AND WHITE PAINT, SIZE AS INDICATED OR SPECIFIED. ELECTRICAL AND MECHANICAL DRAWINGS. EACH STARTER SHALL BE EQUIPPED WITH THREE JURISDICTION AND ANY LOCAL SUPPLEMENT. OVERLOAD RELAYS. MOTOR CONTROL CENTER SHALL BE GENERAL ELECTRIC, WESTINGHOUSE, E-1,1 INTERIOR LIGHTING COMPLIANCE CERTIFICATE. CONDUIT RUN CONCEALED ABOVE CEILING OR IN WALL. ZINSCO OR EQUAL. 43. ALL CONDUIT SHOWN ON THE DRAWING SHALL BE METAL CONDUIT. CONDUIT RUN EXPOSED PARALLEL OR PERPENDICULAR TO STRUCTURE, ALIGN WITH E-2.1 LIGHTING FLOOR PLAN AND LIGHTING FIXTURE SCHEDULE. STRUCTURE. 20, PANELBOARDS SHALL BE CIRCUIT BREAKER TYPE FOR CONNECTION TO BUSSES WITH NUMBER OF 44. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO CIRCUIT BREAKERS AS SHOWN ON DRAWINGS. PROVIDE A TYPEWRITTEN SCHEDULE OF DESIGNATED BE LOCATED WITHIN 25 FEET OF THE FLOOR OR TO THE STRUCTURAL CEILING ABOVE THE SPACE OF E-3.1 POWER FLOOR PLAN AND KITCHEN EQUIPMENT SCHEDULE. CONDUIT"HOME RUN,"CONNECT TO PANEL, TERMINAL CABINET OR TERMINAL BOARD. CIRCUITS ON INSIDE OF DOOR. CIRCUIT BREAKERS WITH MINIMUM INTERRUPTING CAPACITY CAPABLE ELECTRICAL EQUIPMENT. Project Name 85'C Bakery Cafe - USA OF WITHSTANDING THE AVAILABLE SHORT CIRCUIT DUTY. PANELS SHALL BE OF THE SAME E-4.1 ROOF POWER PLAN. MANUFACTURER AS THE MOTOR CONTROL CENTER, 45. 2016 CEC AND CA BUILDING ENERGY EFFICIENCY STANDARS (TITLE 24, PART 6) ARE THE REQUIRED 0 CONDUIT RISING UP FROM BELOW. Project Number CODES FOR ELECTRICAL INSTALLATION. E-5.1 SINGLE LINE DIAGRAM AND LIGHTING CONTROL DIAGRAM Description SYMBOL LIST PROJECT NOTES & 21. THE ELECTRICAL CONTRACTOR SHALL DO ALL WORK REQUIRED TO PROVIDE TEMPORARY • CONDUIT DROPPING DOWN FROM ABOVE. ELECTRICAL SERVICE FOR CONSTRUCTION ILLUMINATION AND POWER FOR ALL TRADES. ALL COST OF SHEET INDEX LABOR AND MATERIAL REQUIRED FOR ELECTRICAL SERVICE SHALL BE IN THE ELECTRICAL CONTRACT I CONDUIT ONLY STUB OUT WITH CAP AND MARKER. Computer File ____ft CONDUIT WITH SEALING FITTING. 22. THE ELECTRICAL CONTRACTOR SHALL CONTACT THE UTILITY COMPANY AND ALL OTHER Scale RESPONSIBLE AUTHORITIES FOR SERVICE REQUIREMENTS, AND SHALL FURNISH AND INSTALL ALL --XR--XR-- EXISTING CONDUIT AND CONDUCTORS. REMOVE ALL CONDUCTORS OR CABLES. IF EQUIPMENT AS DIRECTED, AND AS SHOWN ON PLAN FOR A COMPLETE AND OPERATING SERVICE, CONDUIT IS EXPOSE TO VIEW, REMOVE CONDUIT AND SUPPORTS. Template 4.3 (120101) INCLUDING CIRCUIT PROTECTIVE DEVICE AND SWITCHBOARD, CONDUITS, CONDUCTORS AND METERING, ETC. --xA---XA-- EXISTING CONDUIT TO BE ABANDON IN PLACE. REMOVE ALL CONDUCTORS OR All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of CABLES. smith co. Ilc and were created, evolved, and developed 23. THE LOCATION OF THE SERVICE TERMINATIONS SHALL BE DETERMINED IN FIELD, AND SHALL BE for use on and in connection with the specified project. None of APPROVED BY THE ELECTRICAL AND TELEPHONE SERVING AGENCIES. THE ELECTRICAL CONTRACTOR such ideas, designs, arrangements or plans shall be used SHALL INCLUDE ALL THE REQUIREMENTS IN HIS BID AND NO ADDITIONAL COMPENSATION SHALL BE by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ALLOWED AFTER THE BIDDING PERIOD FOR INACCURACIES IN THESE REQUIREMENTS, E - O . 1 OMch�ckcftware 'Vrsion 4.1.1.Q► COMcheck Software Version 4.1.1.0 Scullion *q. Rough-In Electrical InspectionIcor plies? Cortlelnents/Assulnp#irons InterIrrift or Li Ming compliance certificate Energy Code: 2012 IECC Inspection Checklist c�� ° Autnmatitcontralstoshutaffall ❑complies 1 IEL221? building buildingslightin. g installed in all ❑Does Not ❑Not Observable Requirements: 0.0% were addressed directly in the COMcheck software [Not Applicable 411For Project Information Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each 0405.2.1. Independent lighting controls installed ,❑complies 1 per approved lighting plans and all .Does Not Energy Cede: 2012 IECC requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception IEL2312 manual controls readily accessible and. Project Title B5C BAKERY CAFE is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided, visible to occupants. :phot observable I3Not Applicable Project Type: Alteration Section 0405.2.1 Lighting controls installed to uniformly ❑Cemplfe5 a Plan Review Complies? Comments/Assumptions 2 :reduce the lighting toad by at least ❑Does Not & Reo.1D 1EL1511 50%. ONot Observable Construction Site: OwneriAgent: Designer,Contractor: C103.2 Plans, specifications, and/or OComplies 9588 SW WASHINGTON SQUARE [PR4411 calculations provide all information ❑goes Not Mot Applicable SPACE 0O1 'with which compliance can be 0405.2.2. .Daylight zones provided with ❑Complies ONot Observable a TIGARD, OR 97223 determined for the interior lighting 3 individual controls that control the ❑Does Not and electrical systems and equipment ONot Applicable (FL1.A]2 Icghts independent of general Allowed Interior Lighting Power area [jNat Observable B � ���� C ��� and document where exceptions to lighting, A B C D the standard are claimed. Information ONot Applicable Area Category Floor Area Allowed Allowed Wefts ,provided should include interior C405.2.3 Sleeping units have at least one OComplies ft2 Waifs;fl2 B X C) :lighting power calculations, wattage of IEL.17i3 master switch at the main entry door ❑Does Not S :bulbs and ballasts,transformers and that controls wired luminaires and Nat Observable 1-Bakery store(Commoncontrol devices. switched receptacles. ❑ SpaceTypes:Sales area) 1950 1.80 3120 ONot Applicable 2-Kitchen, Food service(Common Space Types:Food preparation) 1410 1.20 1692 Additional Comments/Assumptions: 9753 S Ill/ Washington Sq Rd 0405.2.2. Occupancy sensors installed in ❑Complies 3-Rest Room(Common Space Types:Restroom) 182 1.00 182 2 required spaces. Oboes Not Total Allowed Watts= 4994 IEL1811 Suite 1302 ONot Observable Proposed Interior Lighting Power ONot Applicable Tigard, OR 97223 A B C D E C405.2.2. Primary sidelighted areas are ❑Complies fixture ID ;Description I Lamp/Wattage Per Lamp.i Ballast Lamps/ # 1E001Cof Fixture (C X D) 3 :cotppsd with required lighting ©Does Not Fixture Fixtures Watt. onntrols. ©Not Observable ONot Applicable Bakery store(Common Space Tyoes.:Sales area 1950 soli.) C405.2.2. Enclosed spaces with daylight area OComplies Kitchen.Food maim(i Common Space Types:Food preparation 1410 so1,11.1 31 under skylights and rooftop monitors ❑Does Notillietal C • Rest Room(Common Space Types;Restroom 182 KA.) fEl 11are equipped with required fighting [Sot Observable L.t,LIE:2'x4•Recess Light fixture:LED Panel 36W: 1 12 36 4$2 controls. 1725 W@shake avenue n LED 1: ONot Applicable suite 210 LED 2:R.BE.Recess fern Light:Otl►er: 1 59 32 1888 C405.2.3 Separate lighting control devices for ❑Complies LED 3:E:Peridant Light:LED A Lamp 12W: 1 3 12 36 {EL4]1 specific uses installed per approved ❑Does Not Seattle, Washington 98109 LEO 4:0:LED Tape Light:Other: 1 2 170 200 lighting plans. []Not Observable LEO 5:C:LED Pendant tight:LED A Lamp 12W: 1 14 12 168 206.838.5485 p ElNgt Applicable LED 6:K:LED TAPE 2W/FT:Other: 1 14 2 28 206.713.4076 m LED 7:F:LED PENDANT:Other: 3 a 27 216 C4.05.3 Fluorescent luminaires with odd ❑complies 206.464.0700 f [EL19] "numbered lamp configurations that ❑Does Not Total Proposed Watts a 2968 are within 10 feet center to center(if •recess mounted)or are within 1 toot ONat observable ksmith@smithco.org Interior Lighting TBD. No fixtures specified for 1 or more area categories edge to edge(if pendant or surface ❑Not Applicable mounted)shall be tandem wired, http://www.smithco.org/ C405.4 Exit signs do not exceed 5 watts per OComplies IEL6I1 face. ❑goes Not Mot Observable Consultant ONot Applicable At4 Alk 0405.2.3 :Additional interior lighting power OComplies IELE111 allowed for special functions per the Elopes Not approved lighting plans and is4 ❑Not Observable k. .automatically controlled and separated from general lighting. Cleat Applicable Additional Comments/Assumptions: 1IP .„ j 1 'High Impact(Tier 1) j 2 (Medium Impact (Tier 2) I 3 ILow Impact(Tier 3 I j I !High Impact(Tier 1) i 2 (Medium Impact(Tier 2) j 3 'Low Impact(Tier 3) I 1P106} l ' and Project Title: 85C BAKERY CAFE Report date: 02/18/19 Project Title: 85C BAKERY CAFE Report date: 02/18/19 Project Title: RSC BAKERY CAFE Report date: 02/18/19 D i 'z& l . Data filename: CaUsersVesslcalDocumentslCOMcheckl85C Tigard.cck Page 1 of 6 Data filename: CeasereeessicalDocumentstCOMrheck185C Tigard.cck Page 2 of 6 Data filename: CAUsersgessical,DocumentetCOMchecke35C Tigard.cck Page 3 of 6 ADR: 3119 Central Parkway, Dublin CA. 94568 TEL: 510-788-6029 CEL: 510-468-0613 FAX: 510-788-6039 Consultant Registration Architect Registration Section # Final Inspection Compiles? Comments/Assumptions & Req.0D 0408,25. Furnished as-built drawings for ❑Complies 1 electric power systems within 30 days ❑Does Not [FI16]3 of system acceptance. ❑Not Observable ONot Applicable 0303,3, Furnished O&M instructions for OComplies 0408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated {F117j3 representative. phot Observable ONot Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the interior lighting fixture schedule for values. [Fi18]1 lighting power is consistent with what ODoes Not is shown on the approved lighting plans.demonstrating proposed watts ONot Observable are less than or equal to allowed Observable,..., Applicable Issues and Revisions watts. 0408.3 iLighting systems have been tested to OComplies No. Date Issues By Check [FI3312 'ensure proper calibration. adjustment, Oboes Not 1 02.07.19 PERMIT SET KLS programming.and .� - L l .. ONot Observable ONot Applicable Additional Comments/Assumptions: Project Name 85°C Bakery Cafe — USA Project Number Description INTERIOR LIGHTING COMPLIANCE CERTIFICATE Computer File Scale Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of l g ImpactiI I # 9 Impactl p l I p I smith co. llc and were created, evolved, and developed 1 'High {Ter 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3) 1 Hi h (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3f for use on and in connection with the specified project. None of Project Title: 85C BAKERY CAFE Report date: 02/18/19 Project Title: 85C BAKERY CAFE Report date: 02/18/19 Project Title: 85C BAKERY CAFE Report date: 02/18/19 such ideas, designs, arrangements or plans shall be used Data filename: C:1UsersaessicalDocuments\COMcheck\85C Tigard.cck Page 4 of 6 Data filename: C:1Users'Jessica\Documents\COMcheck185C Tigard.cck Page 5 of 6 Data filename: CeUsersijessica\Documents\COMcheck185C Tigard.cck Page 6 of 6 by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ile. E - 1 . 1 „, 8rz0 , ) --) A CBD CC”- D CE-- CF_-.} F.5 G 1 I 1 85° CBakeryCafe , ! / OVERRIDE SWITCH "a" & I'b"0 _ i _ _ _ 9753 SW Washington Sq Rd __)01 _ 2--- --------- ei . S , 7 _� I ?TREAD " � \\ , • �� IIS, \ � I Suite D02 / y 4ED 7 WALK-IN li x II 1� rte\ % / i' ..�.� i WALK-IN •COOLER • a . I 4/ ) I // Tigard,d, OR 97223 FREEZER x ; y I L a - f r E WIN - V I ` AL I ftc.... I I 61 161 x �� � _- �n�li � \ / 1 36 {IiYP.) I I ! ,\I I (TYP =;i6R 8) 1D4 '. ' ` ;� \ _I ellith, CO 63 63 A• MI x w 41".... * • i a i 'REP AREA ;--= x I. #�� \\e o © � I I.. ISI I•I P P2 61,61 H 1 0.....1,„ ` - ■ x I ;', ��' ,��� TO ';IOOD LAMP 1725 Westlake avenue n �� �� �> } � ( suite 210 I I 6 161 L`� ; �, P2 41 I I wattle, washington 98109 ��I . 0 _ V' 1 t. I - I�II�I _ - -1111 r-- AL `fI --- 206.838.5485 P U.. _- 1 -_ - `I,. II - ♦•, ,� 63 . I ell"' - �■ ---- X71 • `,-�I�q�l,sl.lwll '`' -' 1 _ ._41_ Nr X11= EYP.) PP.) aE (TYP,) 206.713.4076 m P l 1 v �, • IEu,w IN 1 Q 'a IH[ 36 J 32 32,r , '� 4 4 w xxx i ••• • • xxxxxxxxxxx x xx xx .`,1.. u i KITCHEN / I e 1 II / 206.464.0700 f _ �•� 44,......L AREA l ♦ � "v I IMP t ID 67� Q 63 67 I I • I LJ.ui!_l - - J ��+• 65 ' , I ksmith@smithco.org ���,� - •�_, x 61 61,61H 61 61,61H 1 -,I•,'.`1 64,64H 65 htt /lwww.smithco.or 1 , +' 7411 w I '�' x 64a,6 P 9 4H i ..,; , . -. i- ' ; '� : 67 xxxY xx .• x rxxxxx . �.4. -... ;�....•r._......�... , } 0 O O n �J C ---:.–.. O ��4: ��� i 63 IN 0. 7 0• 63� O O • D ' ' ` [��" ® �■ ® _ - •r _' •' 0 P2 62 64 64H 61,61H __-- 64a 64a,64H 64a0 consultant .., MI III 108 X67 O 6 109 r� ♦ xxxxx tx xx • 0i��� � I'i•►• ••••• • ' ----- Ei&AD Flnl9i `��� = 63 _ ALL/ ALL - 1 � •`i ' Q 63 65 ; • I SERVICE ,` �� mu' I I 64a a,�REP 1 ..14 A �►/ _ GENDER. G NDER AREA 64a 64a,64H 64a 64a,•4H 64a,64H � a 64a 64a,64H 64a 64a 64 — f a likte4-k‘le‘ 2 r p 0, III ® 64a64H Jam; — .) C�64a 41111AP ,� �, «REST'. RETRC O w• OOO O I11 O O O • • 11 •III . i• ••. . • •,�:.e ,.�...« `•..._ 64 •02 y l =,__. O1 64a fL�1 64a,64H 6:_e03...„.. ra,64H____ 64a I`I,`- _ 4-..4rim 1 i -j �. 6 �� . s 62b t 1�2f — 62b 62b 62b .0 ': — .- ... — �jlin ��c) .� �'•. �I� •: �,, _ , 062b _ l62b 62 - _ 633' -i 03 ©3 f 3 (O]�• !+ % P2 67 ♦j• Y:• .-- Lam'-.f��•J.�' [w '\-' �� I ;' ` ��J O I 1/ V © 1II I �� a ® _ 101_ 6 .NI. k I■IISI •� x . • '� --- • ��� --- -.���fr..�__=IIID_-iLr---4. .1. ... j� _.. r 41 •• 63 D I✓. FOR 3) (I X65 J1 �' Nngin ''e' i'zaff and? ��� 63 '+ 63,65,65H 00W��_ � Bevy/ago 63 q'3 63 � 63 63 I 063 63 63 63 �— ��� � � � 1 0 (� 63 ADR: 3119 Central Parkway, Dublin CA. 94568 If I l 063 U I t/ I O L) 1 / 1 TEL: 510-788-6029 • �"� :+ + V 63 102 i CEL: 510-468-0613 sALE5ICu5TOMER `' a 65H .I! ® FAX: 510-788-6039 AREA 65H 4)) (�P) 65H 65H Iii, (TYP.) 65H BREAD 65H ♦ Consultant Registration Architect Registration ��xsr�rx DISPLAY � -- * I ` 1 II 1 1 t7 1 It <1 1 1 In 1 11 65 65 65 65 M,' €-_, _ 65 65 65 65 65 65 65 65 -- II r OI I 11 I ri O �U 'EWA� �� `' = 71, O in Q I Hi Q• I • IN HI • I p L J vII I J 1 0 I ! I I I I I I I r ...-- i I REFERENCE NOTES ® ' ' 1. PROVIDE UN-SWITCHED HOT WIRE CONNECTING TO EMERGENCY BATTERY TO ALLOW NORMAL SWITCHING WITHOUT ACTIVATING EMERGENCY BATTERY. Issues and Revisions 2. PHOTOCELL SENSOR FOR DAYLIGHT CONTROL. Ivo. Date Issues By Check LIGHTING FLOOR PLAN 1 02.07.19 PERMIT SET KLS 093. SEE LIGHTING CONTROL WIRING DIAGRAM ON SHEET"2/E-5.1". SCALE: 3/16" = 1'-0" jIPF LIGHTING FIXTURE SCHEDULE WATTS TYPE DESCRIPTION LAMP ill XT INTERIOR, LI RECESSED LED 2'X4' FIXTURE WITH DIMMING FOR KITCHEN LED 36 ORACLE LIGHTING OT-LED SERIES L1 E SAME AS FIXTURE TYPE "L1" EXCEPT WITH EMERGENCY BATTERY PACK (90 MINUTES MIN.) B RECESSED LED 6" DOWN LIGHT WITH DIMMING LED ;12 ELITE LIGHTING B6 LED SERIES Project Name 85'C Bakery Cafe – USA BE SAME AS FIXTURE TYPE"B" EXCEPT WITH EMERGENCY BATTERY PACK (90 MINUTES MIN.) C LED PENDANT LIGHT LED 1.2 Project Number BARN LIGHT ELECTRIC ORIGINAL WAREHOUSE WITH DIMMING FEATURE Description LIGHTING FLOOR PLAN AND LIGHTING FIXTURE SCHEDULE D LEO TAPE LIGHT W/ EITHER 30W/60W/ICIOW DRIVERS LED 'f-5/FT Computer File EUTE LIGHTING LBIOO SERIES E PEDANT MOUNTED LED LIGHT LED 12 Scale BARN LIGHT ELECIIRC IVANHOE SERIES F PENDANT MOUNTED LED LIGHT. Template 4.3 (120101) ELITE LTG #SCH6-LED-DM2000 LUMEN. BLACK, 0-10 V DIMMABLE LED 27 All ideas, designs, arrangements, and plans indicated or K LED STRIP LIGHT WITH PRZMATIC COVER(COMES IN 1' INCREMENTS) LED 2/FT represented by this drawing are owned by and the property of EUTE LIGHTING ESL SERIES smith co. 11c and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used X1 BUILDING STANDARD LED EXIT SIGN WITH 2-ROTATABLE EGRESS HEADS LED 15 by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. X2 BUILDING STANDARD LED EGRESS FIXTURE WITH 2-ROTATABLE HEADS LED 15 E .. 2 . 1 850 B� ("Cb0 0 . @-) _} C 5°C th� €I, I Bakery Cafe 1 I 8 i I ® r— P2 28 (PROVIDE SHUT-TRIP BREA CR ON BRANCH CIRCUIT) - — — — _ 9753 SW Washington Sq Rd Fl) — — — I — — l I S ,� I r �� I� ,r I I I,, Suite DD2 1tgI iso ai �� iX® s © 40&42 s © O ;):::7 -- III , O XTrgard, DR 97223 0 1 L P1 5 28 z i i����',,• WALK-IN 46&4$ / Ix 1112"C 3#110 & 1#6 GRD, THWN, CU. _ .—_, i FREEZER0O � I rr I I II , \,,41 1 ' --- -- ' — wAL1N -- it �� ! ��I - y • 1 l :READ Ia�EP'I "� '__- ii ' `' '� T DECK OVEN CONNECTION POINT (V.L.) I IIi lei I■I I I TOLTG COOER - Vii P2121& 3: 5 : !II �x� l•;JUASHINGI1/�j' • �• REP AREA 11{ 101#6G�D. LI �� 1 _ _ _ _ _ _ _ - - - - I filaith Ci i .12)3. .0 NI ; SEE ENLARGE[; 1 P2 44,46&48or - 150A 3P I.iI■I ; K 1725 Westlake avenue n (-2---\ , I tall l■I E2.2 SEAL - I „ ; r► suite 210 — °„ P2 45 - X'1 1 _ 1" BREAKER IN NEMA 36 �$ I �/ EF 120V, 113HP I ppe IQ 3$ - ' S L ' 6111�I �- I ENCLOSURE (V.L,) P2 14,16,18 rc 208V, 1PH, I wattle, Washington 98109 °1 P224,26 LcPFOR W.H. �ULATING KITCHEN ' �_� '' • `t r �� MCA = 0.33 206.838.5485 / \ S 17 �; C = AEA 111115.7 fw- I ��� � ` E=� I ' --- - - - -- � ;Ik .; .�� r �T - PUMPS" _. ` 77.:7&39iii&z1-11 s - � ; 205.713.4076 m 1. . 120V 113HP( >02 lr i, S .►.: IH ill 206 713.40760700 t + I <_ —r 1.Ii dllil5ll�,,i,- P2 40,42&44 3f iA 3FI \ _,411, --- ;f••♦ • •..• :xxStx �c,G2cx>C�Cxx�<� •. — —�tP1 40 Q■ • �, , P1 p2SEAL P1 27&29 ® P2 20 45 45O aL,,, u �I' •;11. ' _ • .flyt: ksmith@smithco.org .„...............,p.......,,.. J..2,..t...43,. IL I 1• 40 11 111 0s .II1$ �jtra � � http://www.smithco.org/ 41���• / O rEw` 1� � �� _ 40 1 >u.. f a. 10 O \ I ;1 �• ,� ® --- P1 28 304 4 no K ©24 4 > r © .� 1 _. >•I1 400:0`I N . .:.. /� ilpi 38 -©4 1 .•4110 rrr �' ► • r�._��.: � i.� r r�� 3aCJnSU�tant x. + :0 2, • • mANAGER I i• i r �..a.►11y [t;►r i °m 11� I1, I j����� .,� ■ ri ,, # DESK �► t �, i ..- _ m..0.;: ; — P2 27&29 ll` / CEILING MOUNT RECEPTACLE�� �' ' --- ® 1,a .�:..-:� G I 2P 1. 3 1 / -. -• P ... �� ., «xx r Xxxx .... � �. 2 2 :A,�` ` I-����> �I LL ALL I� ' :• ' '�� -_ •- gas [ �1 SFOR SHOW WINDOVI�'` � GENbER �.,. p €€r,• - � i€:n �— 11�. fl1\ • ENDER 'il+ �� : : $ o n�� cue a+Ea��• • ESTROOM RESTROOM ® • P1 7&9 SERVICE ® ��' �_ii •• P2 13,15 38 04J ' (TYPICAL) 4�� • M, 3 4 �` �'� O REA1 �� ► 1�1 ► 111 1 �'■ _� _ ,=�� f� 6&8 2+��►•���•�, h' 111111 :.� .. xxxxxx P1 .� ._ _. ;. #10 _ @ O_ �i O' O 2 , 2 I 4. �' • �. ► - •,• �F r •: ter//� •��'�'' P1 2,4,6 "� 111it p _ — ;; mil — _ �� w _' I 911 •° 1 - X11 �I■� r..... — _ _ — f1 OL �i' J6 � / ��. �r '►RI �� 7t i .► �.w ��1• I!-7�I��i■��. l ww . ' r�� P142 - li�� ��I�/ _ O ;:� !f! �. • FI " __ '� �R�'aQ1alr� €.���y,r;5@6I'Zt ,I� 11� 17 rlk 1glI �i„� i� 1111 t �I .+!p �.l'I,a:1t/ -11r i•°II' ,ii,,,„ D SII - �L 1-- k 1 ilii��il ■■I�I�■11111:11 1 �1 ,IE 175( 1 ' k Adv-►:�_r ..: 5 • :vi'v >a P2 12 12 �-7• J-1 �J 11eorinfir ..1`..J111 11 P1 15,1 O ,x P1 36,38 �� 0 Q ® 0 ® 0 ® ��' ' �` -'' �' I "" �10 ��� 36 O�`'� ' 20A, 2P , P1 19&21 Q ® 171 32 ADR: 3119 Central Parkway, Dublin CA. 94568 30A 2P P2 10&12P2 9,111 I32 ITEL: 510-788-6029 CEL: 510-�68 0513 ,,,,, IGFI40 P25,7 BREADI 1 22,24,26 F• FAX: 510-788-6039 k GFI 30A, 2P, GFI P1 18,20 �j�dt1 6 SALESARU�AOMEftP1 12,14,16 ' DISPLAY FOR SIGN (V,L) Consultant Registration Architect Registration W.P.#1���..•* i 7 P1 8,10 ,, I I __ O I 18 20 22FOR SIGN (V.L)I, iI -r,- $ � T2 14 IQ fo 36 T10C 36 .� t � �� I_ _ _ j [f ) •.,._ , �� •I �Ir 19 17 �Ir19 11r 17 11r 19 11r 111 .�►• Mfr✓ kk, ''11 w�� ��A '� . I :00% Ei .►.•...... . • 1� UM I'l ' i I 1 17. 3$ 1-�•i 03 � � � 1 I I I I 1 I I P2 17,19 ..,... ..._: i , I POWER FLOOR PLAN SCALE: 3/16" 1'-0" -3. N Issues and Revisions No. Date Issues By Check 1 02.07.19 PERMIT SET KLS KITCHEN EQUIPMENT SCHEDULE ITEM NO. EQUIPMENT DESCRIPTION VOLTAGE/PHASE AMP KW HP REMARKS 6 BAXTER RETARDER PROOFER 208V,3-PHASE 21 PROVIDE NEUTUAL CONDUCTOR I 7 DECK OVEN 208V, 3-PHASE 112 I 9 DOUBLE STACKED OVENS 120V, 1-PAHSE (2)1 +21-8" I 11 WORK TOP REFRIGERATOR 120V, 1-PAHSE 8.2 13 CHOCOLATE WARMER 208V, 1-PHASE 5 24 WORK TOP REGRIGERATOR 120V, 1-PAHSE 8.2 • 37111 " P2 37,39 26 ESPRESSO MACHINE 208V, 1-PHASE 4.6 • 1 +5'-3" I 27 WORK TOP REFRIGERATOR 120V, 1-PAHSE 8.2 57,39-• I 28 TEA BREWER 208V, 1-PHASE 6.35 +4'-10" 11189 - - I 30 MICROWAVE 120V, 1-PAHSE 14 1 • �I� 1- 1 32 WALK-IN-COOLER 1 I208V,3-PHASE 2 VERIFY LOAD WITH VENDOR +5'-3" �� L 33 WAL-IN-FREEZER 39 37 208V,3-PHASE 2 VERIFY LOAD WITH VENDOR 37,09 ^�: 34 HOT WATER DISPENSER 208V, 1-PHASE 19.5 �H7oVV"•♦ ♦'V'♦ 39 ICE MAKER W/ICE BIN 208V, 1-PHASE 9.5 Project Name 85°C Bakery Cafe - USA 43 UNDERCOUNTER REFRIGERATOR 120V, 1-PAHSE 3.3 f71-10 47 COFFEE GRINDER 120V, 1-PAHSE 1.44 Project Number 48 CASH REGISTER 120V, 1-PAHSE 3 48A POS PRINTER 120V, 1-PAHSE 3 Description POWER FLOOR PLAN AND 48B DRINK TICKET PRINTER 120V, 1-PAHSE 3 KITCHEN EQUIPMENT SCHEDULE MANAGER DESK 50A 8' CAKE DISPLAY 120V, 1-PAHSE 1 Computer File 51 REFRIGERATED SELF SERVICE CASE 120V, 1-PAHSE 11 POWER FLOOR PLAN 410 53 UNDERCOUNTER REFRIGERATOR 120V, 1-PAHSE 3.3 Scale 54 AIR CURTAIN 120V, 1-PAHSE 5.1 SCALE: 3/8" = 1'-0" 55 SMOOTHIE BLENDER 120V, 1-PAHSE 15 Template 4.3 (120101} 58A OVEN TIMER 120V, 1-PAHSE 3 I 62 CUP SEALER 120V, 1-PAHSE 0.4 All ideas, designs, arrangements, and plans indicated or I 63 COUNTERTOP MIXER 120V, 1-PAHSE 6 represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed 64 FRUCTOSE MACHINE 120V, 1-PAHSE 3 for use on and in connection with the specified project. None of 70H BREAD DISPLAY SHELVES 120V, 1-PAHSE 1 such ideas, designs, arrangements or plans shall be used 71 TV MONITOR 1ZOV, 1-PAHSE 3 by or disclosed to any person, firm, or corporation for any 88 TIME CLOCK 120V, 1-PAHSE 3 purpose whatsoever without the written permission of smith co. Ilc. 89 DYSON HANDBLADE 120V, 1-PAHSE 1.4 NOTE:VERIFY KITCHEN EQUIPMENT LOADS,CONNECTION POINT, OUTLET CONFIGURATION AND MOUNTING HEIGHT WITH VENDOR PRIOR TO ROUGH-IN. . 3 ■ 15 85°' A B C (D) E •,..__./ 85° y Baker Cafe --i 7 — I _ I - - I — - - _ I 9753 SW Washington Sq Rd 0 — -- — — — r- Suite D02 P2 49&51&53 208V, 3PH KEF — 30AS/15AF D Tigard, 4R 97223 FLA 3.4 01 3P, W.P. 1 I0 --I � I I I I 11"pith C. . CONDENSING UNIT F �� 30ASI15AF FOR W.I. FREEZER , 1725 I suite 210 tlake avenue n I I (VERIFY LOAD WITH VENDOR) I 3P,W.P. 2 31&33&35 I I seattle, Washington 98109 CONDENSING UNITGFI/W.P. AM 208V, 1 PH 206.838.5485 p FOR W.I. COOLER ' I 01 VICA = 13 206.713.4076 m �� (VERIFY LOAQ WITH VENDOR) 30AS/15AF = 206.464.0700 f I " 3P, W.P. 22 I LL -- F — — I— L--- I I ksmith@smithco.org all © 30ASI20AF httpa/www.smithco.orgl GFIIW,P. 22 2P, W.P, P2 50&52&54 P2 32&34&36 Consultant P1 31&33&35 I I IAl Ailk GFIIW.P. 1 1"C-3#4& 1#10 GRD. d. 22 THWN. CU. P2 41&43 Amy — P2 22 _ — — — Til �•� —•i —30AS, 3P, W.P. — _ — .._ — — — — — 02 - i:a I I 208V, 3PH RTU _ �`°'�� trolI I I FLA = 45 0l � 1 ! 60AS/50AF, 3P, W.P. LI'_1'.."--...,...,F nnai� 208V, 3PH ' ' and . 01 FLA 4,6 �'�' 6' '1IJO' ' y • I ADR: 3119 Central Parkway, Dublin CA. 94568 LI I TEL: 510-788-6029 I j><1'\." �- I I CEL: 510-468-0613 FAX: 510-788-6039 i Consultant Registration Architect Registration 1 II I 1 I I I I I I 1 I I J I I I I I I I I I I Issues and Revisions No. Date Issues By Check 1 02.07.19 PERMIT SET KLS ROOF POWER PLAN 1 SCALE: 3/16" = 1-0" -4. 1 0 N REFERENCE NOTES 0 1. PROVIDE 1/2" C.O. FOR INTERLOCKING CONTROL. WIRE BY MECHANICAL CONTRACTOR. Project Name 85°C Bakery Cafe — USA Project N Descriptionumber ROOF POWER PLAN Computer File Scale Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. lic and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. PANEL ' P1 ' (NEW) VOLTAGE: 120/208V. 3PH 4W. MOUNT: RECESS BUS AMPS: 225A LOCATION: TEMAMT S[ACE MAIN: M.L.O. FED FROM: EXIST MAIN SWBD EXISTING MAIN SWITCHBOARD EMS„ BREAKER LOAD CIRCUIT CKT TOTAL V-A CKT CIRCUIT LOAD BREAKER - - - - - - - - - T - - - - - _ - - - - - - 85.0 / # AME' POLE LTG REC MSC KITCH DESCRIPTION V-A A 8 C V-A DESCRIPTION KITCH MSC REC LTG AMP POLE # 120'20$V, 3PH, 4W, 2500A BUS 1 20 1 1 #89 DYSON HANDBLADE 1400 3000 1600 SHOW WINDOW __(J 1 * 20 1 2 I— ---I—X— 3 20 1 1 * #89 DYSON HANDBLADE 1400 3000 1600 SHOW WINDOW 1 * 20 1 4 i I r f EXISTING 7 EXISTING 5 20 1 1 * #54 AIR CURTAIN 720 2320 1600 SHOW WINDOW 1 * 20 1 6 ! EXISTING I `Ml #55-414-340 ,Ml #65-479-913 7 20 1 * #28 TEA BREWER 3200 4800 1600 SHOW WINDOW 1 * 20 1 8 /2500AS I 9 - * - 3200 4800 1600 SHOW WINDOW 1 * 20 1 10 114 2500AF I k 11 20 I * #28 TEA BREWER 3200 4800 1600 SHOW WINDOW 1 * 20 1 12 13P 1 EXISTING 1 EXISTING 13 - * - 3200 4800 1600 SHOW WINDOW 1 20 1 14 I o�200A 1200A 15 20 1 1 * #11 WORKTOP REFRIG. 1000 2600 1600 SHOW WINDOW 1 20 1 16 i Y I I 3P I 3P 17 20 1 1 1 * #63 COUNTER TOP MIXER 720 2320 1600 SHOW WINDOW 1 * 20 1 18 I i I — O II O 5°C 19 30 1 * #34 HOT WATER DISP 2100 3700 1600 SHOW WINDOW 1 * 20 1 20 _ � Bakery Cafe 21 - * - 2100 3700 1600 SHOW WINDOW 1 20 1 22 L___.. - - T `� - - 23 30 1 * #34 HOT WATER DISP 2100 3700 1600 SHOW WINDOW 1 * 20 1 24 25 2 - * - 2100 3700 1600 SHOW WINDOW 1 * 20 1 26I +/ 27 20 1 * #39 ICE MAKER 988 2588 1600 SHOW WINDOW 1 * 20 1 28 / I 29 2 - * - 988 2588 1600 SHOW WINDOW 1 * 20 1 30 r— — —X— — — --X-- — J X 9753 SW Y V Y ashington Sq Rd 31 50 * 1 RTU-01 5400 6600 1200 SIGN 1 * 20 1 32 33 I * - 5400 6600 . 1200 SIGN 1 * 20 1 34 35 3 * 5400 6300 900 GENERAL RECEPTACLE 5 20 1 36 - EXISTING GROUNDING liu:aerdoR�237 30 1 * #6 PROOFER 2520 3420 I 900 GENERAL RECEPTACLE 5 20 1 38 EXISTING FEEDER TO POWER SYSTEM TO REMAIN ---� O 97223 39 - * - 2520 2920 400 GENERAL RECEPTACLE 2 20 1 40 Co. SERVICE TRANSFORMER AS IS 2"C-4#3/0& 1#6 GRD. 41 3 - * - 2520 2820 300 #19D WATER FILTER 1 20 1 42 THWN. CU. (PROVIDED BY LANDLORD) Q SUBTOTAL CONNECTED VA; 300201 262081 24848 DEMAND CALCULATIONS: 11 Init k 0 410 a 25%CONTINUOUS LOAD & 25% LARGEST MOTOR: 10650 1. GENERAL RECEPTACLE 100%=10,000VA NEW NEW 65%KITCHEN EQUIPMENT LOAD: I 22474 2. GENERAL RECEPTACLE OVERIOKVA50%=(28,600-10,000)X50%=9,300VA PANEL PANEL 1725 westlake avenue n TOTAL CONNECTED VA: 79624 3. KITCHEN EQUIPMENT LOADS AT 65%=22,474VA suite 210 P1 P2 PROVIDE BY LANDLORD WITH seattle, Washington 98109 TOTAL CONNECTED AMPS: 4.OTHER EQUIPMENT LOAD:=1,700VA (2) EMPTY PANEL 5. RTU-1 UNIT LOAD WITH 25%LARGEST MOTOR=20,250VA 195A 174A 206.838.5485 p 6. SHOW WINDOW AND SIGN 25%LCL LOAD:26.400VA X 25%=6,600VA _ A 206.713.4076 m TOTAL PANEL LOADS:70,324VA=195AMP @208V,3-PHASE,4-WIRE - '" - - - - - - - - -' 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ SINGLE LINE DIAGRAM PANEL ' P2 ' (NEW) SCALE: NONE 4, Alik Consultant VOLTAGE: 120/208V. 3PH 4W. MOUNT: RECESS BUS AMPS: 225A LOCATION: TEMAMT S[ACE fir .i, MAIN: M.L.O. FED FROM: EXIST MAIN SWBD REFERENCE NOTES ® BREAKER LOAD CIRCUIT CKT TOTAL V-A CKT CIRCUIT LOAD BREAKER # AMP POLE LTG REC MISC KIFCH DESCRIPTION V-A A 8 C V-A DESCRIPTION KITCH MSC REC LTG AMP LE # 1, LANDLORD TO PROVIDE NEW 100% RATED BREAKER. `.r4 1 20 1 1 * #55 SMOOTHE BLENDER 720 1820 -. _ 1100 #71 TV,#64 FURCTOS 4 20 IPO1 2 3 20 1 1 #55 SMOOTHE BLENDER 720 2620 : 2100 #34 HOTWAIER DISP * 1 30 / 4 2. LANDLORD CONTRACTOR TO CLARIFY FEEDER VOLTAGE DROP SHALL BE LESS THAN 2%, 5 20 1 1 * #47 GRINDER 1440 3640 2100 • l ` 6 4' lztoor • 1irand 7 20 1 2 #48 CASHIER#64 FRUCTOSE 360 2660 2300 #26 EXPRESSO # 30 g 8 D sier ' ces Co 9 25 1 3 P.O.S. 540 2840 : is 2300 - * 2 10 11 20 1 3 P.O.S. 540 _ 1680 1320 #51 SELF SERVE REFRIG * 1 20 1 12 ADR: 3119 Central Parkway, Dublin CA. 94568 TEL: 510-788-6029 13 20 1 1 #50A CAKE DISPLAY 1300 2288 : = > '':. 988 #13 CHOCOLATE WARM ER * 1 20 1 14 CEL: 510-468-0613 15 20 1 1 #50A CAKE DISPLAY 1300 2980 ; 1680 #30 MICROWAVE OVEN * 1 20 1 16 FAX: 510-788-6039 17 20 1 5 #70H BREAD DISPLAY 90o TiMW Min 1884 984 #24 WORK TOP REFRIG * 1 20 1 18 Consultant Registration Architect Registration 19 20 1 5 #70H BREAD DISPLAY 900 1740: 840 #53 U.C.REFRIF,#64 FRUCTOS * 2 20 1 20 21 150 * #7 DECK OVEN(58b) 13400 13940 540 ROOF RECEPTACLE 3 20 1 22 23 * - 13400 14264 864 13-01, 113HP 1 15 1 24 25 3 * - 13400 14264 864 EF-02, 1I3HP 1 15 1 26 27 15 1 FC-01 100 iMlii 1324 1224 #27 WORK TOP REFRIG#9 3 20 1 28 29 - 2 - - 100 Mii ipM 300 200 #58A TIME CLOCK 2 20 1 30 PHOTOCELL 3115 1 Ke-oi 410 962 552 MAU-01 1 5/ 32 ON ROOF 33 - • 410 962 '€ ' € : 552 • - 34 CONDUIT AND CONDUCTORS = OVERRIDE "a” "b" 35 3 410 _ - 962 552 • - 3 36BY-PASS TIMER ARE REQUIRED FOR LIGHTING il 37 20 1 4 MANAGER DESK 720 1220 Ai 500 W.I.COOLER LT * 1 20 1 1 38 AND POWER CIRCUIT 39 20 I 1 4 MANAGER DESK 720 1620;_;:::;;;; 800 W.I.COOLER EVAP * ... e›,------ 40 41 20 1 CU-01 1352 2152 800 - * - 42 43 � - 1352 1662 WiWaii UN 500 WI rrc r. c LT * 1 20 I 1 44 45 20 1 2 RECEPT FORW.H.(GAS) 400 1200 800 W.I.rxr�crrc EVAP * 1 15 46 PANEL 47 20 I 1 SPARE o 800 800 * - 48 "P2' 49 20 * 1 CONDENSINGW.I.FREEZER 1319 2638 ' : -: '!' 1319 CONDENSINGW.I.COOLER * 1 20 50 51 * - - * - 1319 2638 1319 52 Issues and Revisions 53 3 * - - 1319 ' 2636 1319 • * - 3 54 LCP = r . A No. Date Issues By Check 55 SPACE 0 SPARE 20 1 56 57 SPACE .....i 0 Is]il:,ii SPARE 20 1 58 1 02.07.19 PERMIT SET KLS 59 SPACE 0 SPARE 20 1 60 61 20 1 13 KITCHEN LTG 464 1232 € € lis'' 768 FOOD SERVICE LTG 24 20 1 62 C9 \ 63 20 1 27 SALES AREA LTG 424 Mei no :' 356 FOOD SERVICE LTG 10 20 1 64 SURFACE - MOUNT CONDUIT AND CONDUCTORS 65 20 1 16 SALES AREA LTG 612 _ i 512 SPARE 20 1 66 ......:....:.�.��� GREENGATE #LK-24 TO CONTROLLED LIGHTING 67 SPACE 0 s €€ SPACE 68 69 SPACE 0 iiiiiiiN SPACE 70 AND POWER CIRCUITS, ALSO 71 SPACE a SPACE 72 -��-�`�������=�°=��=��...:.:...:... LCP ID: LCP INCLUDE UN-SWITCHED HOT 73 SPACE 0 a € ' € SPACE 74 LOCATION: TENANT SPACE CIRCUIT 75 SPACE 0 :::: ;; SPACE 76 77 SPACEi1!ii.`' ' .i4 0 SPACE 78 SUPPLY CIRCUIT: 79 SPACE 0 SPACE 80 81 SPACE 0 ° ;;; SPACE 82 1 Relay Circuit Description Switch/Sensor 83 SPACE 0 SPACE 84 1 1 P2-63 SALES/SEATING TIME CLOCK, PHOTO SENSOR DIMMING OVERRIDE SWITCH a I 2 P2-65 SALES/SEATING TIME CLOCK, PHOTO SENSOR DIMMING OVERRIDE SWITCH a SUBTOTAL CONNECTED VA: 306761 31004E 28912 25% CONTINUOUS LOAD & 25% LARGEST MOTOR: 1620 3 P2-67 RESTROOM TIME CLOCK, ORVERRIDE SWITCH a 65%KITCHEN EQUIPMENT LOAD: 42802 4 P2-61 KITCHEN TIME CLOCK, ORVERRIDE SWITCH b TOTAL CONNECTED VA: I 69166P2-64 FOOD SERVICE/SALES TIME CLOCK, ORVERRIDE SWITCH b TOTAL CONNECTED AMPS: I 192 5 6-13 P1-2-16 SHOW WINDOW TIME CLOCK, PHOTOCELL OVERRIDE Project Name 85°C Bakery Cafe USA 14-18 P1-18-26 SHOW WINDOW TIME CLOCK, PHOTOCELL OVERRIDE 19 P1-28 SHOW WINDOW TIME CLOCK, PHOTOCELL OVERRIDE Project Number Description SINGLE LINE DIAGRAM AND LIGHTING 20 P1-30 SHOW WINDOW TIME CLOCK, PHOTOCELL OVERRIDE CONTROL WIRING DIAGRAM 1 21 P1-32 SIGN TIME CLOCK, PHOTOCELL OVERRIDE Computer File 22 P1-34 SIGN TIME CLOCK, PHOTOCELL OVERRIDE 23 - - - Scale 24 - - - Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or LIGHTING CONTROL WIRING D IAG RAM 010 represented by this drawing are owned by and the property of smith co. llc and were created, evolved, and developed for use on and in connection with the specified project, None of SCALE: NONE such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E - 5 . 1