Plans (147) F PS2O 19-00080 - = )CIYO� 00 N- j�OIF�T�IG�AROP� D FOR CODE COMPLIANCE S. LIANCE AREVoEvs � c>.N I LxN _ N c,,c,, C.Lr' Ard1.detss:. �� ( =r�Q�QrY r �` r, , pin Johnson 0(0 4111. - -> ooLL Controls Sute#- � toO 13 ... ._ N� By: Date: iC 0 01 CD •' MIC U 0c)C A L 0T • Ocr W Oo inw cnOv DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS0 k 2.< Ca Ca :ill JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK WITH THE Sales Representative Drawings Prepared By LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2014 Edition BRYAN ADAMS MARIA GERRONE BRYANADAMS@JQ.COM MARIA.GERRONE@JCI.COM Oregon Fire Code,2014 Edition PHONE:503-683-9000 PHONEE 03 IV #12600987 DECEIVED Oregon Mechanical Specialty Code,2014 Edition Scheduling JUN -5 2019 FIRE ALARM SYMBOL LEGEND Oregon Electrical Specialty Code,2017 Edition FAITH KASKE CITY OF TIGApp SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE FAITH.KASKE@JCI.COM BUILDING DIVISION Sheet List Table TYPE National Fire Alarm Code(NFPA 72),2013 Edition PHONE:503-683-9000 PLEASE PRO'�iu:� Sheet# Sheet Title PANELS COMPLETED NFF:A IFA-001 COVER SHEET NAC6 4009 IDNET NAC EXTENDER PANEL,120 VAC,BEIGE SIMPLEX 4009-9201 SIMPLEX CABINET N/A RECORD OF IFA-101 DEVICE PLACEMENT PLAN-6TH FLOOR COMPLETION A INITIATING DEVICES IFA-501 PANEL DETAIL&CALCULATIONS FINAL II'JSI�ECT'_. . ' T IFA-701 WIRING TYPICALS O ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ SIMPLEX 14098-9714 HEAD14"OCT,1 1/2"D M STANDARD BASE 14098-9792 BASE I NOTIFICATION APPLIANCES # CONVENTIONAL MULTI CANDELA STROBE,WALL MOUNT, SINGLE GANG V OCCUPANCY TYPE(S): SPRINKLER PROTECTION: WHITE,CLEAR LENS,FIRE SIMPLEX 4906 9103 1-1/2"D # CONVENTIONAL MULTI-CANDELA STROBE,CEILING MOUNT, V B Business Group BUILDING IS FULLY SPRINKLED SIMPLEX 4906-9104 SINGLE GANG WHITE,CLEAR LENS,FIRE 2-1/2"D n # CONVENTIONAL MULTI-CANDELA HORN/STROBE,WALL V I ISIMPLEX 4906-9129 4"SQ.1-1/2"D MOUNT,WONALMAR MULTI-CANDELA SCOPE OF WORK PROJECT DIRECTORY # CONVENTIONAL MULTI CANDELA HORN/STROBE V ��� SIMPLEX 4906-9130 4"SQ.1-1/2"D C ,CEILING MOUNT,WHITE,CLEAR LENS,FIRE END OF LINE RESISTOR,3.3K(EOL) SIMPLEX 4081-9002 MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES,RELOCATE AND DEMO EXISTING DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 END-OF-LINE RESISTOR 4.7K(EOL) SIMPLEX 4081-9003 '1Mr#K END OF LINE RESISTOR,6.8K(EOL) SIMPLEX 4081-9004 ALL NEW WIRING TO BE CLASS B. LINCOLN 2 1 220 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A END OF LINE RESISTOR,10K(EOL) SIMPLEX 4081-9008 TIGARD,OR 97223 LAKE OSWEGO,OR 97035 NOTE EXISTING DEVICES SHOWN SHADED FOR REFERENCE. THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE PHONE: 503-683-9000 CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 SERVICE:503-683-9001 Installer POINT MONITOR CORPORATION DESIGN STATEMENT 5863 LAKEVIEW BLVD,STE 100 LAKE OSWEGO,OR 97035 ACCEPTABLE DESIGN IS FOR FIRE ALARM NOTIFICATION OF SUITE 650. CABLE TYPES FIRE ALARM WIRE LEGEND VD VI0 0 CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES a a = E o � LU V VISUAL 2 COND.SOLID 14 AWG X X IFI CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2" 0.12 SQ.INCH* 1-1/4" 0.60 SQ INCH* I �' tn 0.21SQINCH* 1-1/2" 0.82SQINCH* , ABBREVIATIONS LEGEND DEVICE TAG LEGEND 3/4" 0 1" 0.34 SQ INCH* 2" 1.34 SQ INCH* *40%CONDUIT FILL PER N.E.C. STP=SHIELDED TWISTED PAIR l - ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION.THE AC= ABOVE CEILING NEC = NATIONAL ELECTRIC CODE ply INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE AFF = ABOVE FINISHED FLOOR NFPA = NATIONAL FIRE PROTECTION ASSOCIATION PANEL DESIGNATOR I... m • REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. AHJ=AUTHORITY HAVING JURISDICTION NIC =NOT IN CONTRACT • FA:=FACP(NON-NETWORK) ALM = ALARM NPU =NETWORK PROCESSING UNIT • #:=NODE NUMBER CI- ANN = ANNUNCIATOR NTS =NOT TO SCALE • T#:=TRANSPONDER NUMBER BMS =BUILDING MANAGEMENT SYSTEM PAP=PRE-ACTION PANEL • #:T#=NODE:TRANSPONDER NUMBER C =CEILING MOUNTED RC = EXISTING TO REMOVE AND COVER • N#:=NAC EXTENDER NUMBER c CD=CANDELA RATING RD= EXISTING DEVICE TO BE RELOCATED DET =DETECTOR RL =RELOCATED DEVICE CIRCUIT DESIGNATOR DGP =DATA GATHERING PANEL RR = REMOVE EXISTING&REPLACE WITH NEW • A#:#=EPSs NUMBERIDNAC2 CHANNEL NUMBER E =EXISTING TO REMAIN SCC= STATUS COMMAND CENTER • D#=DOOR HOLDER CIRCUIT NUMBER �y S EOL = END OF UNE SLC = SIGNALING LINE CIRCUIT • F#=FIRE PHONE CIRCUIT mm, EPO =EMERGENCY POWER OFF SMK = SMOKE • H#=AUDIBLE(HORN)CIRCUIT NUMBER -' FAA = FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY • M#=IDNET LOOP NUMBER L, FACP = FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER • P#=POWER CIRCUIT NUMBER X11 FATC = FIRE ALARM TERMINAL CABINET TRBL = TROUBLE • S#=SPEAKER CIRCUIT NUMBER = M FBO = FURNISHED BY OTHERS TS =TAMPER SWITCH • V#-VISUAL CIRCUIT NUMBER o FCC= FIRE COMMAND CENTER TYP=TYPICAL 0 • Z#=ZONE NUMBER FSD=FIRE SMOKE DAMPER UON =UNLESS OTHERWISE NOTED Q Ce FTR = FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER DEVICE NUMBER 0H - HIGH HUMIDITY VT - VALVE TAMPER BRANCH/ISOLATED LOOP DESIGNATOR: Z HT = HEIGHT W =WATTAGE • (L#)=IDNET ISOLATED LOOP NUMBER HVAC = HEATING VENTILATION&AIR CONDITIONING W/ = WITH • (#)=IDNAC BRANCH NUMBER 3 NUMBER:BRANCH NUMBER N (E#:#)=EPR m N IMS =INFORMATION MANAGEMENT SYSTEM W/O = WITHOUT • z MAX =MAXIMUM WF = WATERFLOW r�rti r� 1.EPS=ENHANCED POWER SUPPLY z W ,, MIN = MINIMUM WG = WIRE GUARDN/A =NOT APPLICABLE WP= WEATHERPROOF 1:T2:A2:1-:.(E1:1) 2.IDNAC=ADDRESSABLE NOTIFICATION CIRCUIT in 3.EPR=ENHANCED POWER REPEATER NAC =NOTIFICATION APPLIANCE CIRCUIT XP = EXPLOSION PROOF N 0 0Ce NDU =NETWORK DISPLAY UNIT 0 V 0 0 0 0 SYSTEM SEQUENCE OF OPERATIONS V oo ce 4� z Q N � a J - _ISI- g O lJ ± Q E. CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL SUPPLEMENTARY 1 •4� o P • SGP 6* Qac' �`� Ge k,-c��C� = c'D DAG 4" 4' • �,P c,��v�P J� �`��cJQ��J �, li- ecy- OJ p cp cp°� o� c') s�V ,`�O JPS i OF 5 '''`O Q', g- 5 5 5 c GQ G c, .`O �V \, cG '\° k, 0 5 �5 F, Q - O } P P P P P ww O '�W'W 0 ,i, �� c pP GENERAL NOTES RISER DIAGRAM SYSTEM INPUTS A B C D E F G H 1 J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH REMARKS 1 SMOKE SENSOR/DETECTOR • • • • • • • • • • 1 s 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN RISER NOTES: 2 MANUAL PULL STATION • • • • • • • • 2 THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 3 DUCT SENSOR/DETECTOR • • • • • • • • 3 zo 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK 4 ATRIUM BEAM DETECTOR • • • • • • • • • • 4 a SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM 5 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR5 a ARCHITECTURE IN BUILDING CROSS SECTION.IT IS NOT INTENDED TO • • • • • • • • • • • • 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO REPRESENT ACTUAL WIRE RUNS,PANEL CONFIGURATIONS OR 6 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • • 6 W ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE.ALL CHANGES SHALL BE 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • 7 PENETRATIONS.REFER TO FLOOR PLANS AND PANEL DETAILS FOR CLEARLY INDICATED ON THE RECORD DRAWINGS. 8 8 Ne CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. 9 9 v 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT BREAKER,AND REFER TO'APPLICABLE CODES&STANDARDS'ON SHEET FA 001 FOR 10 WATERFLOW SWITCH • • • • • • • • 10 SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL' THE LOCATION OF THE CIRCUIT 11 TAMPER SWITCH • • • • • • 11 v DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. SPECIFIC CODE REFERENCES. 12 12 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 3. DEVICES ARE TYPICAL SEE FLOOR PLAN FOR QUANTITY&LOCATIONS. 13 FIRE ALARM AC POWER FAILURE • • • • • 13LLI DAYS AFTER FINAL TEST. 4. EXISTING DEVICES ARE SHOWN SHADED FOR REFERENCE. NEW AND 14 FIRE ALARM SYSTEM LOW BATTERY • • • • • 14 a RELOCATED DEVICES ARE SHOWN BOLD. • • • . • 15 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 15 OPEN CIRCUIT o 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 16 GROUND FAULT • • • • • 16 0 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE KEYNOTES: 17 NOTIFICATION APPLIANCE CIRCUIT - CLASS B/STYLE Y: ce 17 N a o ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 18 WIRE-TO-WIRE SHORT • • • • • 18 = 2 ^'• 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL CEILING,AND ROOF ASSEMBLIES ANY TIME THAT WORK IS O RELOCATE END OF LINE RESISTOR. MAINTAIN SUPERVISION. 19 19 NOT ACTIVELY BEING PERFORMED. 20 20 0 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD V 21 21 (1:NAC6:V4)AAA yA C (' 1:NAC6:V4 22 22 i.- WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL 10K ""•UM ) ) ) ��� C 23 23 DRAWN R.HERMANT CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. 24 24 CHECKED BY: R. g 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. (RL) O V M.GERRONE 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE (1:NAC6:V3)10 () 1:NAC6:V3 I- 25 25 ISSUE DATE: 5/31/19 WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 26 26 JOB#: 14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. rV 27 27 PROJECT#: 448:613139801 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN (1:NAC6:V2) ' ( E.< 1:NAC6:V2 0 28 28 JOHNSON CONTROLS©2019 TMJ 29 30 30 SYSTEM: SHAFTS SHALL BE TYPE FPLR. C C 29 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. rV 31 I 31 FIRE ALARM SYSTEM 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL (1:NAC6:V1) cc ( ( 1:NAC6:V1 J� CODES,WHERE APPLICABLE. 10K ) ) C S ) A B C D E F GH I JK LMNOPQR S T U V W X Y Z AA AB AC AD AE AF AG AH SHEET: 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 4009 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. NAC6 COVER SHEET 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT WILL BE USED LOCATED IN I - iu 5120 VOLT AC ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE ELEC ROOM N CONDITION OF EXISTING CONDUITS. "-, IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the 6TH FLOOR a project for which it was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or FA-001 • reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend, x indemnify,and hold Johnson Controls harmless from any and all claims for loss,damage or injury arising directly or indirectly from any such o unauthorized use. ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. %. W--.40 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. V c)(-4 o 0 KEYNOTES: z <> RELOCATE END OF LINE RESISTOR. MAINTAIN SUPERVISION. C 0 o a 1:1-L..- . Oa LE VI Cul ~M O 1-o-. Oa'SDI NC V0O� OCO co mr to 1 a O``` t-,1-6) ~f/f OYcc 1 2 (p3 4 5 363 7 8 9 SUITE 650 AREA OF WORK D iII I LJ 4i ISIOFFICE OFFICE OFFICE OFFICE ' I 606 I 605 I 604 I I 603 I30 1_0 30DE ) . CONFERENCE 1:NAC6:V3 5 DECK 666II 7ii--: — T7'C 602 LH H ', CONFERENCE OPEN lo—VPI OFFICE NT I 607 I I 612 I (RL) l:NAC6:V4 2 o--V / DECK 1:NAC6:V4-4 111-V 30 15 ) " [PI 1 1 1 LV 75 I 1 I Q 30 1:NAC6:V3 6 O V LV ��� C V—o ( (1:NAC6:V3) _ �.n 1:NAC6:V4-3 10K ......2.i 15 (RL)O 1 (1:NAC6:V4) ,H, W lOK� SERVER OPEN ENTRY � BREAK/COPY 1:NAC6:V4-5 609 OFFICE II 110 1 �, I 608 I V.O. STOR E I 601 ( 'I 0)110 1 610 I 611 1:NAC6:V4-1 1:NAC6:V3 4 I I �1:NAC6:V3) 110 i ` ,' °D-- �I— — i — © lOK I , _ v 1 i _ ' _ - - - in 7. Q 15 1:NAC6:V1-9 O V S 1:11-20971-: V 15 :NAC6:V14 SUITE �C � TO NAC6 1:M1-207 M C •y tz 1:M1-208,1 I m 640 � a M .o V—C3 1 - low I a G Q SUITE I z 1 1 l:h„'C6:V:.-3 1:N' ..‘ 5 600 - 1:M1 21( — r' `. tJ [] (1:NAC6:V� O15 i �� V "G "' I 30 15 J f. i I i i i 1Lh i f5 V� 15 :` IAC6:V1-3 C • BREAK � 1 L I 1:NAC6:V:.-1C :I a: C6:V1-7 1:NAC6: 6 O 1:NAC6:V3-3 0 I - - - -z - E 1:M1-206 li.... / 2 o -I- \ 0 L' - CC � Q o D ' ii OPEN OFFICE i� j 1 p Q Q Q Q Q L.. Z CC M I I BREAK I I i ' N m evl • 1:Ml201 W N NE Z IA W Ce al 4: , A L! ,41 L1:M -202 ! 1:M1-205 TI' `1 N W CL 1:N: 6:V1-1 Q 0 1:M1-204 1:NAC6:V1-2 , �i� 75All I4 15 15 C ©1:M1-20: V J 0 t'• CB) - �:NAC6:V2-1 Li cc .' 2V - H L[i - O O 4 u I 4 2 zgo PRINT/FILE VJ 2VJ immil .ma li III= �, I o I I TO NAC6 PANEL W OFFICE OFFICE A `�V ISUITE 1 I I I I 1=1 OPEN OFFICE o 10 �V 610 (1:'JAC6:10 C 15 c 1:NAC6:V2-4 . - 1 " " 1:NAC6:V3-1 V V WELLNESS RM • 075 ._, - ,�, C / 75 V 1:NAC6:V2-3 75 OFFICE OFFICE ©1:NAC6:V3-2 cc T BREAK IMI C F Q I 1:NAC6:V2-2 I I I I cc OFFICE w DECK m 0 L>' J Z O k a a u El S lJ . Q 8 W a F o F 0, O _ hd M CC Ot 0 N M tt0 0 Z DRAWN BY: R.HERMANT E CHECKED BY: M.GERRONE s ISSUE DATE: 5/31/19 JOB*: PROJECT#: 448:613139801 JOHNSON CONTROLS©2019 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN - 6TH FLOOR - N„, , A _ . N W .- -5 -......- - =ie DEVICE PLACEMENT PLAN - 6TH FLOOR ' N SCALE: 1/8" = 1'-0" SCALE:1/8"=1'-0" IN FEET FA- 101X 0 0 4' 8' 16' ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. amme.....S cm), or`l 0-i up Ln 74.41Z11111111144 corn rn 00 Vil Ln,n LZ-1 C -x o .1., n_, VOLTAGE DROP SUMMARY V)o r, LINCOLN 2 6FL N ELEC NAC6 4009 NAC O op 8 Standby Total Alarm Total Plan o co Circuit Description Load Drop �o� Description Standby1 1:NAC6:V1 _ 6FL HORN/STROBES-CORE SIG1 0.780A 4.65% O 7' 6 20 Module Qty P Current Current Alarm o Panel Equipment I:NAC6:V2 6FL HORN/STROBES SUITE 604/610 SIG2 1.070A 4.37% 02 ,,,o_v 4009 9101 1 4009 IDNET NAC EXTENDER,120 VAC I I:NAC6:V3 6FL HORN/STROBES SUITE 600-650 SlG3 0.941A 6.90% I- O Tr,`-�> 0.08I 50 0.0850 0.1850 0.1850 1:NAC6:V4 6FL HORN/STROBES-SUITE 650 SIG4 0.631A 1.94% c up J"' Panel Totals 1 0.0850 1 0.1850 3.422A Total Notification Appliances Setting POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES. 4906-9103 8 V/O MC NON-ADDRESS,WHT,WALL 15 0.0000 0.0000 0.0600 0.4800 4906-9103 2 V/O MC NON-ADDRESS,WHT,WALL 30 0.0000 0.0000 0.0940 0.1880 I 1:NAC6:V1 Distributed Load Voltage Drop 4906-9104 2 V/O MC NON-ADDRESS, WHT,CEILING 15 0.0000 0.0000 0.0750 0.1500 Allowable%Drop: 17.9% Wire Res.Per Ft 0.003070 @ 75°Celsius 4906-9129 2 A/V MC NON-ADDRESS, WHT, WALL 110 0.0000 0.0000 0.2850 0.5700 Wire Gauge: 14ga Min.Device Voltage: 16.vdc 4906-9129 2 A/V MC NON-ADDRESS, WHT, WALL 75 0.0000 0.0000 0.2210 0.4420 Starting Voltage: 19.5vdc %Voltage Drop 4.65% 4906-9130 1 A/V MC NON-ADDRESS, WHT, CEILING I10 0.0000 0.0000 0.3200 0.3200 Circuit Capacity 2.A Normal Operation 4906-9130 3 A/V MC NON-ADDRESS, WHT, CEILING 15 0.0000 0.0000 0.0860 0.2580 Distance Device Voltage Voltage At 4906-9130 2 A/V MC NON-ADDRESS,WHT,CEILING 30 _ 0.0000 0.0000 I 0.1320 0.2640 Device# PID Setting (Feet) Current Drop Device 4906-9130 3 A/V MC NON-ADDRESS, WHT, CEILING 75 0.0000 0.0000 0.2500 0.7500 1:NAC6.'VI-1 4906-9104 I5cd 44 0.075 0.211 19.29 Peripheral Totals 0.0000 3.4220 1:NAC6.:V1-2 4906-9130 I5cd 36 0.086 0.367 19.13 1.NAC6:V1-3 4906-9130 30cd 55 0.132 0.576 18.92 System Totals*: Standby 0.0850 Alarm 3.6070 1:NAC6:V1-4 4906-9130 IScd 32 0.086 0.671 18.83 1:NAC6:V1-5 4906-9103 IScd 45 0.060 0.782 18.72 1:NAC6:V1-6 4906-9103 IScd 12 0.060 0.807 18.69 1:NAC6.:V1-7 4906-9103 IScd 18 _ 0.060 0.838 18.66 Standby Standby Alarm Alarm 1:NAC6:V1-8 4906-9103 I5cd 12 0.060 0.855 18.65 Battery Set#1 (Cabinet/Charger#1) Current Total Current Total 1:NAC6:V1-9 4906-9130 I5cd 39 0.086 0.893 - 18.61 Select ALL Power Supplies on this battery set: 1:NAC6:V1-10 4906-9104 I5cd 31 0.075 0.907 18.59 Totals: 324 Ft. 0.780A 4009 0.0850 3.6070 Sub Total 0.0850 3.6070 Total 0.0850 3.6070 I 1:NAC6:V2 Distributed Load Voltage Drop Allowable%Drop: 17.9% Wire Res.Per Ft. 0.003070 @ 75°Celsius Standby Time= 24 Hrs x 0.0850 =2,0400 Standby Ah Wire Gauge: 14ga Min.Device Voltage: 16.vdc Alarm Time= 5 Min 0.08333 x 3.607 =0.3006 Alarm Ah Starting Voltage: 19.5vdc %Voltage Drop 4.37% Ckt Capacity I 2.A 2.3406 Normal Operation Additional Spare Battery Capacity= 0% + 0.0000 Distance Device Voltage Voltage At 2.3406 Device# PID Setting (Feet) Current_ Drop Device BatteryDischarge Factor 1:NAC6:V2-1 4906-9130 75cd 45 0.250 0.296 19.20 9 = 20% + 0.4681 1:NAC6112-2 4906-9130 75cd 52 0.250 0.557 18.94 Minimum Battery Required 2081-9272 6.2AH (2x) 2.8087 I:NAC6:V2-3 4906-9130 75cd 52 0.250 0.739 18.76 Battery Supplied 2081-9272 6.2AH (2x) 1:NAC6:V2-4 4906-9130 110cd 57 0.320 0.851 18.65 Q *System Totals represent total system current requirements.Those currents may be distributed between multiple battery sets or power supplies as shown above. Totals: 206 Ft. 1.070A Ln W 11:NAC6:V3 Distributed Load Voltage Drop I~I Allowable%Drop: _ _ 17.9% Wire Res.Per Ft. 0.003070 @ 75°Celsius Wire Gauge: 149a Min.Device Voltage: 16.vdc Starting Voltage: 19.5vdc %Voltage Drop 6.90% VI c, IF OPTIONAL SHIELDS ARE USED FOR IDNet WIRING. Ckt Capacity 2.A I 1 LL FOLLOW THESE PRECAUTIONS. Normal Operation 1. IF IDNet WIRING CONTINUES ON TO ANOTHER DEVICE,TAPE Distance Device Voltage Voltage At �� M pew pm# Setting (Feet) Current Drop Device rn SHIELDS TOGETHER.DO NOT TERMINATE SHIELD AT 4009 FROM PREVIOUS IDNet DEVICES I 1:NAC6:V3-1 4906-9103 I5cd 105 0.060 0.607 18.89 IDNet. / 7 ' OR HOST IDNet CONTROL PANELC I 1:NAC6:V3-2 4906-9129 75cd 20 0.221 0.715 18.79 2. IF IDNet WIRING TERMINATES AT 4009,TAPE SHIELD.DO NOT M 1:NAC6:V3-3 4906-9103 I5cd 75 0.060 1.019 18.48 a r TO ADDITIONAL IDNet DEVICES 2 TERMINATE SHIELD AT 4009IDNet. U `• 1:NAC6:V3-4 4906-9129 110cd 45 0.285 1.185 18.32 aOR RETURN TO HOST IDNet CONTROL PANEL D IDNet CONTROLLER ADDRESS: l:Ml 201 1:NAC6:V3-5 - 4906 9103 30cd 50 0.094 1.281 18.22 r-:-, 1:NAC6:V3-6 4906-9129 75cd 47 0.221 1.345 18.15 1:NAC6:V4 I Totals: 342 Ft. 0.941A c 1:NAC6:V3 • J = 1:NAC6:V2 11 1:NAC6:V1 ' 1:NAC6:V4 Distributed Load Voltage Drop2 O 0 V c V -V 0 R Allowable%Drop: 17.9% Wire Res.Per Ft. 0.003070 @ 75°Celsius Qce Wire Gauge: 14ga Min.Device Voltage: 16.vdc 3 - Starting Voltage: 19.5vdc %Voltage Drop 1.94% Z Et LI Ckt Capacity 2.A N < m M Normal Operation Z N I ® ' = Distance Device Voltage Voltage At W n Ce al ® - ® Device# PID Setting (fit) Current Drop Device "' 1:NAC63 .'V4-1 4906-9129 110cd 45 0.285 0.174 19.33 ,m,- ,m._ 000 immroeeol ®®1®© o Q m m 11:NAC6:V4-2 4906-9103 30cd 40 0.094 0.259 19.24 0 IV N 'ALM ALA! ,ALM .AVM ,ALM-KM, .A�, -ALM >m '� ''' IDNET I 1:NAC6:V4-3 4906-9130 30cd 60 0.132 0.352 19.15 NAC1 IOC NAC3 NK4 '� ° IA1azw SW) 11:NAC6:V4-4 4906-9103 I5cd 26 0.060 0.371 19.13 -I In 0 - e,,.,,m,., 0 11:NAC6:V4-5 4906-9103 I5cd 17 0.060 0.378 19.12 Z �V N Q Totals: 188 Ft. 0.631A N W -E H . a if Z J II= :3 ..-1 H tT °7 B, °7 V moi' inn E[3 [n°7 0 ' AUX POWER ��CC ` a + 4E) C>...5). 10 E 3 ❑ ❑ POS IN ` y c POS OUT HARDWIREI O o 0 \O 7 C E G RET IN NEVI O 2 a�.FFL N RET OUT VISIBLE O POS IN D O g.. 0 POS OUT HARDWIRE 0 g Cl \ 0 / RETIN INPUT2 '^ RET OUT AUDIBLE BATTERY 0 / c, 4009-9201 IDNet NAC EXTENDER I�iaj I O O • • ■ A)TRESSABLE NAC SYSTEM O19 ASSY 0665-7/1 ABC O © @ /,%/ //A/ / 1 %�j_Th INTERNAL BATTERY `7HARNESS 733 991 HARNESS 733-945 g �,� /1/ GROUND , �,"+� //, NEUTRAL -CONNECT TO 120VAC 60HZ INPUT 3A MAX. / NOT 120V m lm SR a o STRIP �// < PART OF N 733-991 / 6.2 Ah BATTERY 6.2 Ah BATTERY z 0 E 2081-9272 2081-9272 ` L, Cep M / v 0 CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY Li GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO THE 4009 SAFETY GROUND STUD. I- a 0 cti ri al NAC6 2 a LOCATION: 6TH FLOOR,ELEC ROOM rn w NTS o a DRAWN BY: R.HERMANT CHECKED BY: M.GERRONE ISSUE DATE: 5/31/19 JOB#: PROJECT#: 448:613139801 JOHNSON CONTROLS V 2019 SYSTEM: FIRE ALARM SYSTEM SHEET: PANEL DETAIL& CALCULATIONS N N LeiL V Q FA-501 x O m C Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. h Nirgew ala —alwiratql O N 01 ill tD MLA co[D .. `111 M O O to 1.rl • Co z o 413 c C ~m O N O.__I mc 10°-ce VMo l0 DEVICE MOUNTING HEIGHT REFERENCE END OF LINE RESISTOR CODES TrueAlert CONVENTIONAL APPLIANCES % Wen ,,ZSW PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED VISUAL cn Lu I- Los N OYc:G c ocWii VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY NOTE:REFER TO PANEL/MODULE AND DEVICE OF LENS FOR 110CD STROBES WITHIN 16'OF THE PILLOW OR RETURN THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS PlIj! INSTALLATION INSTRUCTIONS FOR PROPER e),_,....., STANDARD ELECTRICAL BOX _ 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER ELECTRICAL BOX oMOUNTING 4"SQUARE BOX 1-1/2" (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 TERMINATIONS. �.' DEEP o; o Cp IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3'(914mm) 4 — NOTE:MEASUREMENTS MODEL REFERENCE OHMS BAN'.)NUMBER WATTS CIRCUIT TYPE FIRE ALARM o, SURFACE MOUNT ADAPTER r . NUMBER 1 2 3 4 5 PANEL/MODULE o; SKIRT 15/8"(41mm)DEEP. - / \I-- MINIMUM CEILING (102mm) SHOWN ARE TO THE CLOSEST 4081-9001 733-892 2.2K RED RED RED GLD N/A 1/2 ANNUNCIATOR(4300) 4004,4010(TROUBLE) 4lj viiiiiiiiiiiiiiiiiii ////iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii ////iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii v iiiiiiiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiii ///////7 / / EDGE OF THE DETECTOR CONDUIT CUTOUTS ARE ������ ������� N.O.INITIATING PULL,SMOKE, 4004*,4004R,4005*,4006, r ♦ Q °� PROVIDED ON ALL FOUR SIDES. —� CEILING MOUNTED I ll 4081-9002 733-893 3.3K ORG ORG RED GLD N/A 1 HEAT,WATERFLOW,TAMPER,ETC. 4100,4120,4100U,ZAMs t ��` o FOR CEILING HEIGHTS LESS THAN 86"(2180mm), NFPA 72 AUDIBLE APPLIANCE 6"MIN 4" - • SURFACE MOUNTING THE VISUAL LENS MOUNTING HEIGHT SHALL BE (152.4mm MIN)BELOW FINISHED CEILING SMOKE/HEAT (102mm) 24 PT.I/O SWITCH SUPV. 4605-7401,4100 SERIES i� '�_ . - CLICK HERE TO DETECTO 12"(MAX) CURRENT LIMITED N.O.INIT. 4090-9001 IDNET IAM(EOLR) S CHANGE WIRING WITHIN 6"(150mm)OF THE CEILING. ACCEPTED HERE 1/ (305mm MAX) 14081-9003 733-896 4.7K YEL VLT RED GLD N/A 1/2 NOTIFICATION(DACT) 2080-9024 � SI'LE 0 - i r4= 0 HEAT DETECTORS 4004,4005,4090-9001 ' . 'llf I N.O.INITIATING PULL,SMOKE, IDNT IAM 2190-9173 V CANDELA INTENSITY (-)I+) L-)(+) C , NEVER HERE ill 4081-9004 733-886 6.8K BLU GRY RED GLD N/A 1/2 MAPNETII 2 PT I/O PLUG ACCESSIBLE FROMFLS F R E , __FIRE-- HEAT,WATERFLOW,TAMPER,ETC. II� !II AUDIBLE/VISUAL AUDIBLE ONLY WALL MOUNTED" 4-20MA ZAM(TROUBLE) \r' REAR OF HOUSING I ]!i!Iii,l ,• r, TO EXIT DOOR SMOKE/HEAT / 4081-9005 733-984 1.8K BRN GRY RED GLD N/A 1/2 CURRENT LIMITED N.O. 4090-9001 IDNET IAM (' /���� _ . & MI VISUAL ONLY 5,(MAX) DETECTOR- I INITIATING(IN LINE) APPLIANCES 90"MIN(2286mm MIN)ABOVE FINISHED (5 ) 4005*,4090-9001 IDNET IAM (-) - (-) TO NEXT DEVICE FLOOR(OTHER MOUNTING HEIGHTS SHALL 14081-9006 733-890 560 0 GRN BLU BRN GLD N/A 1 N.C.INITIATING(EOLR) TOP OF LENS: NAC CIRCUIT OR EOL SYNCHRONIZE MORE BE PERMITTED BY THE AHJ PROVIDING IT 4100,4100U 96"(2044mm)A.F.F MAXIMUM (+) (+) RESISTOR THAN TWO APPLIANCES MEETS THE SOUND LEVEL OUTPUT REQUIRED.) 4081 9007 733 891 1.2K BRN RED RED GLD N/A 1 N.C.INITIATING(EOLR) 4005 FOR CEILINGS<86"(2180mm)AF.F.: 4004,4005,4006,4008,4009, � <=6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE • IN ANY FIELD OF VIEW. 96"MAX(NFPA,ADA) MAGNETIC DOOR (127mm) I 4081-9008 733-894 10K BRN BLK ORG GLD N/A 1/2 NOTIFICATION 4010.4100.41000 CLASS B WIRING I 4081-9009 733-912 20 0 RED BLK BLK GLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT I/O BOTTOM OF LENS: WIRING NOTES (2440mm MAX) HOLDER SIDE WALL N.C.INIT.(ACROSS CONTACTS) 4005*,4090-9001 IDNET IAM 80"(2032mm)A.F.F.MINIMUM ABOVE FINISHED FLOOR 24 PT.I/O(ACROSS CONTACTS) 4605-7401,4100 SERIES REF.80"MIN(IBC) TO TOP OF LENS ri F FINISHED 4081-9010 733-973 1K BRN BLK RED GLD N/A 1 CURRENT LIMITED N.O.INIT. n ,� 1. MAINTAIN CORRECT POLARITY ON TERMINAL WALL 4090-9001 IDNET IAM MOUNTING OPTION B CONNECTIONS. (2032mm MIN) REF.96" 80"MIN(ADA) DOOR (IN SERIES WITH CONTACT) 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER MAX(IBC)(2440mm MAX) WIDTH _ 4081-9011 733-974 100 0 BRN BLK BRN GLD N/A 1/2 ANNUNCIATOR(N2) 4006,4008,4010 TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. (2032mm MIN) FIRE [STATION MANUAL PULL LESS 3" 4081-9012 733-985 22K RED RED ORG GLD N/A 1/2 SPEAKER CIRCUIT 4003 ABOVE FINISHED FLOOR 80"MIN(NFPA) PHONE (76mm) 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ (2032mm MIN) 4081-9013 734-086 4.99K YEL WHT WHT BRN BRN 1/2 APPROVED METHODS. N.C.INITIATING(SECURITY TO BOTTOM OF LENS JACK 4081-9014 734-092 2.4K RED YEL RED GLD N/A 1/2 MONITORING EOLR) 4090-9001 IDNET IAM • ilI 14081-9015 734-093 1.5K BRN GRN RED GLD N/A 1/2 CURRENT uM11 EU N.U.LNLI. 4090-9001 IDNET IAM MOUNTING OPTIONS NOTE:REFER TO THE PROPER DEVICE (SECURITY MONITORING EOLR) 48"MAX(ADA)(1219mm) INSTALLATION INSTRUCTIONS48"MAX(NFPA,ADA)(1219mm MAX) 14081-9016 734-149 150K BRN GRN YEL GLD N/A 1/2 OPTION1 DESCRIPTION NOTE FOR BACKBOX MOUNTING HEIGHT. 42"MIN(NFPA)(1067mm MIN) 4081-917 734-171 3.9K ORG WHT RED GLD N/A 1 A SINGLE GANG BOX,1-1/2"(64mm)DEEP BY OTHERS.WHEN SURFACE 14081-9018 734-168 10K BRN BLK ORG GLD N/A 1 70VRMS CONSTANT SUPV.NACS 4100-1260 MEASUREMENTS SHOWN ARE I 378-090 8.2K GRAY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,4100U B 4"(102mm)SQUARE BOX 1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR FINISHED TO TOP OF PULL HANDLE I C 2 GANG BOX,1-1/2"(38mm)DEEP 4906-9940(WHITE)SKIRT 378-046 5.6K GRN BLU RED GLD N/A 1/2 N.O.SECURITY MON.(SERIES) 4100,41000 - f FLOOR ! 378-069 12K BRN RED ORG GLD N/A 1/2 N.C.SECURITY MON.(SHUNT) 4100,4100U D SIMPLEX 2975 9145,7-7/8"H x 5 118"W x 2-3/4"D ORDERED SEPARATELY *USE WITH RETROFIT OR HIGH CURRENT MODULE (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRECOM TrueAlert CONVENTIONAL APPLIANCES TrueAlert CONVENTIONAL APPLIANCES o • SIMPLEX 4906 SERIES WALL MOUNTED MULTI-CANDELA AUDIBLE/VISUAL SIMPLEX 4906 SERIES CEILING MOUNTED AUDIBLE/VISUAL LA VD ELECTRICAL BOX PROVIDED LU ELECTRICAL BOX STANDARD ELECTRICAL BOX BY ELECTRICAL CONTRACTOR. 1 CD MOUNTING 4"SQUARE BOX, 011 NOTE:DO NOT BRING o ® 1-1/2"DEEP 0 0*..., t CONDUIT THROUGH THE 1 SURFACE MOUNT REAR OF THE ELECTRICAL BOX. .' \ 0 0 ADAPTER SKIRT 15/8" .! VI3 ��• ° (41mm)DEEP.CONDUIT _— 0 I i LL rj' � __ /�-J4014- CUTOUTS ARE PROVIDED �, r'` SURFACE MOUNTING JIlz-T /" 7C °� ON ALL FOUR SIDES. I f O �\ � ►� o 11 ao 144 � A GI pE'� R - CANDELA INTENSITY + + O O .� / w• PLUG ACCESSIBLE FROM —-- O — O ) i U..- . �'"'I N -- \�` �/ REAR OF HOUSING l'Olri l pl 101? .�. • . ji (+) ���� TO NEXT DEVICE g II IB. 0 STROBE CIRCUIT -- (-) (_) OR 10K RESISTOR ry \ INTENSITY SELECTION 0 `TOP OF LENS: (-) - (_) TO NEXT � PLUG,ACCESSIBLE ~� NAC CIRCUIT Jj DEVICE OR .. TERMINATION VIEW:DEVICE MOUNTING PLATE 96"(2044mm)A.F.F MAXIMUM ONLY FROM REAROF 0 �� iiii O�l FOR CEILINGS<86"(2180mm)A.F.F.: (+) (+) EOL RESISTOR ��� HOUSING CLASS B WIRING �I <=6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE MAGN C TES 1 imma - - BOTTOM OF LENS: CLASS B WIRING LOCATION 80"(2032mm)A.F.F.MINIMUM WIRING NOTES STROBE INTENSITY SETTING WIRING NOTES o VIEWABLE THROUGH THE Ca MOUNTING OPTION '"B" 1. MAINTAIN CORRECT POLARITY ON TERMINAL LENS 1. MAINTAIN CORRECT POLARITY ON TERMINAL CI CC CONNECTIONS. CONNECTIONS. 0 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER MOUNTING OPTION "A" 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER ilY 45 TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. TERMINALS.NEVER LOOP WIRES UNDER TERMINALS. 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ e4 <X 02 Z N APPROVED METHODS. APPROVED METHODS. .crit, Z IA LU r%`" MOUNTING OPTIONS - CWG MOUNTING OPTIONS 72- OPTION' DESCRIPTION NOTE Ce A SINGLE GANG BOX,1-1/2"(64mm)DEEP OPTION' DESCRIPTION NOTE 0V " 0 BY OTHERS.WHEN SURFACE MOUNTING USE 4905-9937D/ Z (RED)OR 4906 9940(WHITE)SKIRT B 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM A 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM BY OTHERS km) ........IIin (0 5 C 2 GANG BOX,1-1/2"(38mm)DEEP SURFACE MOUNT 4"(102mm)SQUARE BOX 1-1/2"(38mm)DEEP, 4905-9915(WHITE)OR 4905-9916(RED)ADAPTER Z < o N °C SIMPLEX 2975 9145,7-7/8"H x 5-1/8"W x 2-3/4"D • B MINIMUM RECOMMENDED,ORDERED SEPARATELY V " Q a) D (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE ORDERED SEPARATELY 2 Z C op N 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX FIRE.COM r.:71 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM 2. 4905-9928 ADAPTER PLATE REQUIRED WITH OPTIONAL 4905-9927 RED WIRE GUARD E J .3 C 3 0 L - C O .] a, C c Q LU W } m 0 w N H Z 0 Ed U W 0 • v a0 v W Ir Q 0 FL 05 le 'I W ce ma al '4 2 rN-. ,-1 _ 0 N m leo 0 z DRAWN BY: R.HERMANT F._CHECKED BY: M.GERRONE N ISSUE DATE: 5/31/19 JOB#: PROJECT#: 448:613139801 JOHNSON CONTROLS©2019 SYSTEM: FIRE ALARM SYSTEM SHEET: WIRING TYPICALS _ a, !P) .--1 W V Q_ N FA-701 X M ©Johnson Controls 2019.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited.