Plans (135) F PS2O 19-00070 S OPE O F WORK FIRE ALAR' / RISER DIAGRAM INSTALL A NEW ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM WHICH N JUNRECEIVED-3 219 iTY CSF TICAP10 LODE SPRINKLER FLOW AND TAMPER VALVE MONITORING, $�1�I^�'�'� t1�+ � CENTRAL STATION OFF-SITE REPORTING , MANUAL PULL STATIONS, SMOKE DETECTORS, HORN/STOBES, LOW FREQUENCY SOUNDER/STROBES AND LOW FREQUENCY SOUNDERS. GENERAL NOTES 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR SHALL BE RISER RATED. w 4 4 Q1 QD 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. sziZ VA © f21 Vi Z 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTNING PROTECTION DEVICES. CD 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY SLC TO FACP z I PROTECTED. 18/2C FPLR _ N 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS 0 w c/ "FIRE ALARM CIRCUIT". OFFICE COP w 01Z Cil cn z 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE > m z EJ CITY OF TIGARD m Op8 NFPA72). FOR CODE COMPLIANCE z w 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION REVIEWED a z w FIRE ALARM FL - ul OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA72). ANNUNCIATOR PANEL Approved�[.� ] �- o 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR (CORRIDOR t05) OTC: [ I m z cn z AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH SECTION 51061/T4 DI TO FAAP Z U) Z 18/4C FPLR Permit#: FPca�))ce - EYJ() 7 O 0 w Ln 14.6.2.4 (NFPA72). Z Z Ln i- 11. A LOCKABLE DOCUMENT STORAGE CAN SHALL BE PROVIDED. Address: ra <‘., S�,a) b�� 1 Q CD a a 12. ALL JUNCTION BOX COVERS SHALL BE PAINTED RED. © Suite#: 13. PAINT FIRE ALARM SYSTEMS OUTLET BOXES/JUNCTION BOXES RED. rf By: Date: �-�'- I d I. WATERFLOW EEU- FACP :, FIRE TYPICAL NAC DART ALARM 14/2C FPLR CONTROL DIGITAL PANEL ALARM RADIO 12OVAC DEDICATED 12OVAC DEDICATED VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION PLEASE PROVIDE DOCUMENTS AND OTHER COMPLETED NFPA 72 DATA SHALL NOT PREVENT RECORD OF THE CODE OFFICIAL FROM COMPLETION AT REQUIRING THE CORRECTION FINAL INSPECTION OF ERRORS. OSSC 105.4 1N N U rn b -1 I I Oo O O w .-.•-- I I-- ") to en >- O O DJ O Ox U I } W Q U CD ~ LL Q Q Z W � C� _ > Q' rnw U < vT m �- I- 100LA z W z Q O 1= (/1 � w U z < in00 L- THIS PLAN AND ANY ACCOMPANYING DOCUMENTS ARE THE WORK PRODUCT AND THE PROPERTY OF ACTION TECHNOLOGY ANO MAY NOT BE USED, COPIED OR REPRODUCED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF ACTION TECHNOLOGY. DELIVERY OF -THIS PLAN AND ANY ACCOMPANYING DOCUMENTS TO THE BUILDING I OWNER,HIS CUENTOR ANY CALCULATIONS CONTRACTOR IS CONDITIONED UPON NATTERY FIRE ALARM OPERATIONAL MATRIX ' THE ABOVE UNDERSTANDING AND j ANY VIOLATION OF THIS CONDITION ! MAY BE ENJOINED AND/OR REDRESSED IN DAMAGES IN ANY COURT HAVING JURISDICTION OF THE POTTER SUBJECT MATTER. AFC - 50 SYSTEM OUTPUTS jRevisions: STANDBY TIME (HRS): 24 LOC. ALARM TIME (MIN): 5 O`, 4P\, PART # DESCRIPTION (QTY STANDBY STANDBY TOT ALARM ALARM TOTAL 'e e‘ �c,�P �O� AFC-50 MAIN CIRCUIT BOARD I 1 0. 1300 0. 1300 0.2000 0.2000 P PAD 1 00-PD PHTOELECT ADDR HEAD 1 1 0.0003 0.0003 0.0003 0.0003 ��P�' ��'� 0G pF, �O\. `� Action Tech. Job No: PAD 1 00-PSSA ( PULL STATION ADDR I 2 0.00021 0.00041 0.00021 0.0004 G�� 0G p� ��`�c\' OC)o� ��' ��� 12.16.18 PAD100-SIM ( MONITOR MODULE I 5 0.00021 0.00121 0.00021 0.0012 • O Q �<p� FPGQaq�� �'�04���,p0 �`�O�P�O Date: RA-6075 ( REMOTE ANNUC. 1 1 0.02001 0.02001 0.0250 0.0250 vQ �cO SPG 0Q- P- Q� �O����� \`���� p�C �F, �G�' NTS FQ 0 FQ -1 -1 O c� Q� C� p� �Q� F, MBA-246 FLOW BELL I 1 0.0000 0.0000 0.0600 0.0600 P� ��Q �P �� \mac c PJ J\ �Q �`P PJ J�`� �4J Scale: UD- 1 000 DIGITAL INTERFACE 1 1 0.01 60 0.01 60 0.02301 0.0230 \, \, J , .<<, .\F. �F, 4, G< G<, 5 �4 �4 JO Jp cQ- <5' JP JP JP zi, `a is STEVEN KIRKLAND 0.0000 0.00001 0.00001 0.0000 SYSTEM INPUTS P, PSP ��o ��O �JQ c7- P,''` \,.) P�''` c�\, �\�<c•���`c ��G, CERT NO.111689 0.0000 0.00001 0.00001 0.0000 NOTES: FASDR-0032-4000 PULL STATION • • • • • Drown By:0.00001 0.00001 0.00001 0.0000 SMOKE DETECTOR • • • • • STEVE BARRY 0.0000 0.0000 1 0.0000 0.0000 I 0.0000 0.00001 0.0000 0.0000 I I I Checked By: STANDBY AMPS 0. 1679 ALARM AMPS 0.3099 SPRINKLER FLOW SWITCH i • I • I I I I I • • I • I • I I I Drawing Title: STANDBY Ah = 4.0296 ALARM Ah = 0.0258 SPRINKLER TAMPER SWITCH ( I I I • • i I I I I I • I • I I I I I COVER- X AMP I IE HOURS REQUIRED = 4.0554 I RISER DIAG DERATE LOSS OF AC POWER AT FACP • • CALCULATIONS BATTERIES TO BE INSTALLED = 7.0 AMPERE HOURS OPEN CIRCUIT I • • I I PERMIT DISCONNECTION OF BATTERIES I I • I • I I I I I I I I APPLICATION GROUND FAULT I I I • I • I I I I I II I I I I I Drawing Number: PRESS SIGNAL SILENCE KEY I I I I I I • I • PRESS RESET KEY I I I ( I I I I • I I- A 1 ,. 0 CI.) `2. L3� t4� C5!..) `62 ® CO) ' rp� �nJ j ,� DARIIFACP\� CLi ChiU 01)curb • L — S 1� 1814 FPLR �- T I FIRE ALARM SYMBOL LEGEND: �_ 18/2 FPLR_ -- \ CACP FIRE ALARM CONTROL PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL z � N \ DART DIGITAL ALARM RADIO TRANSMITTER J0 Cpl t - -I - ' - \I - C ® MANUAL PULL STATION _ m o CI \ m O E \ SMOKE DETECTOR Q W SDUCT SMOKE DETECTOR Q \ \ \ ❑Z SINGLE INPUT MODULE m Q 0 Q I I \ SPRINKLER WATERFLOW INDICATOR z w r SPRINKLER VALVE TAMPER Q 0_ gP WATERFLOW BELL co \ \ SCJ I • I I I _ _ I N. I\AP RTU6 RTU5 ` 111\:\j4r200P 1W FPLR ©D S O �' I8r'.FPLR mIU I1 / 1812 ERR _ J 01 MI 1 1 I L i _i Frb- / I - L _I `NOW )3N r `©J ] — — — — — f — — C I I I / I I -el 1 L Ir � I I (.,m �� e Ji -4 1 7�� ��� F/ 7 d 9 - L _1t7 ° ° BREAK ROOM I] im I. 1 / 14 , .Q I u .H U co I�oxv. — — — - - )i I I I 0 C] f.o d C. ' , CV c\F i 7 O r L - - - - Pr- —.-_."- f� °� -r - - - I - -- I1 - ^r---, d LES - - n . U U u t�-v a tiJ 1..?-1u��-u-11 u U ..1--u u tlJ�(Ju u F— a COm 110vWATERFLOW BELL 1r ��U I DONE BY OTHERS 1 J I [ I 1 1 I Cr) U I QZ Z r-. O' 1 cow 3PROPOSEDMAINFLOORPLAN 118»,1'-0" o 0 R. - zoo a F— to pi. E Ua Z Q "' O U Gl7 THIS PLAN AND ANY ACCOMPANYING DOCUMENTS ARE THE WORK PRODUCT AND THE PROPERTY OF ACTION TECHNOLOGY AND MAY NOT BE USED, COPIED OR REPRODUCED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF ACTION TECHNOLOGY. DEUVERY OF THIS PLAN AND ANY ACCOMPANYING DOCUMENTS TO THE BUILDING OWNER,HIS CUENT,OR ANY CONTRACTOR IS CONDITIONED UPON THE AROYE UNDERSTANDING AND ANY VIOLATION OF THIS CONDITION � �� �� �\ �� MAY BE ENJOINED AND/OR r ,� ' !A 1 �] (A ] c-6-_-\.) C. [7 } (�} } MAY IN INJURISDDAMAGESICTION N ANY cI J ci) J ��J `J �`+J COURT HAVNG JURI�ICTION OF THE SUBJECT MATTER. Revisions: Ii - - ST - - El— — — --Ei — — 0 - I I I e) e) e) � I „, , E 10) • a 11) M�) Action Tech. Job No: 0) ID) 05.16.1 9 I I I I !II) NO Date: No man I �') �) 3/32” = l' 0" ter. Scale: C — — — ---- — — — — — — — — --- - — C I) DM e) STEVEN KIRKLAND CERT NO.11689 I I I I ) m) o) 1 SDR 003214000 M111) NO) 119) ..) rBrawn 8y. Ni 111) O) OM 0) STEVE BARRY 11 ) WID 00) 1 Checked By. _ I ; ) l.) 0) 0) I 0) fit_) �) — 7 Drawing Title: — — — — — — - - r- �- - - - - - ) i .0) �) 0) I FIRE ALARM FLOOR I FLAN C - - t r`-1_I v u u u a is u u u PERMIT APPLICATION Drawing Number: 1 7 `} PROPOSED MEZZANINE FLOOR PLAN A4 I 1/8"=1.-0., 1- A 1 , 1